Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:03
Tabular Output Report in Format: HTML
Building: OfficeLarge
Environment: RUNPERIOD 1 ** International Falls Intl Ap MN USA TMY3 WMO#=727470
Simulation Timestamp: 2023-10-16 09:03:35
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 33013.63 | 712.72 | 712.72 |
Net Site Energy | 33013.63 | 712.72 | 712.72 |
Total Source Energy | 94739.86 | 2045.32 | 2045.32 |
Net Source Energy | 94739.86 | 2045.32 | 2045.32 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 1.200 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil No 1 | 1.050 |
Fuel Oil No 2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 46320.38 |
Net Conditioned Building Area | 46320.38 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 3895.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 2944.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 3710.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 672.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 15213.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 1941.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 2507.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 502.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 722.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2848.73 |
Humidification | 31.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.60 |
Heat Recovery | 56.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 816.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2280.17 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 28302.01 | 4711.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5140.50 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler | 0.00 | 3895.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 2944.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 3710.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 672.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 5871.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
DataCenterPlugLoads | 9341.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 87.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 1848.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 5.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Fans | General | 2507.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 502.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 722.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2848.73 |
Humidification | General | 31.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.60 |
Heat Recovery | General | 56.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2280.17 | |
Water Heater | 0.00 | 816.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Unassigned | 0.00 | 3895.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | Unassigned | 2944.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GENERAL | 3710.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | Unassigned | 672.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | GENERAL | 15213.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | Unassigned | 1941.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Unassigned | 2507.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | Unassigned | 502.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | Unassigned | 722.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2848.73 |
Humidification | Unassigned | 31.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.60 |
Heat Recovery | Unassigned | 56.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Unassigned | 0.00 | 816.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2280.17 |
Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 94.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 144.81 | 101.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 |
Other | 371.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 611.01 | 101.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 94.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 144.81 | 101.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 |
Other | 371.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 611.01 | 101.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 28302.011 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 28302.011 | 100.00 |
Total On-Site and Utility Electric Sources | 28302.011 | 100.00 |
Total Electricity End Uses | 28302.011 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | 0.00 |
Air to Air Heat Recovery for Cooling | 188.46 | 3.80 |
Air to Air Heat Recovery for Heating | 4768.68 | 96.20 |
High-Temperature Geothermal* | 0.00 | 0.00 |
Solar Water Thermal | 0.00 | 0.00 |
Solar Air Thermal | 0.00 | 0.00 |
Total On-Site Thermal Sources | 4957.13 | 100.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 5140.50 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 5140.50 | 100.00 |
Total Water End Uses | 5140.50 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 206.33 |
Time Setpoint Not Met During Occupied Cooling | 149.67 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 5941.17 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICELARGE
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 7
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MN_INTERNATIONALFALLS
| Environment |ZoneCoolingSummaryMonthly
| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |ZoneHeatingSummaryMonthly
| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |ZoneElectricSummaryMonthly
| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |SpaceGainsMonthly
| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM |PeakSpaceGainsMonthly
| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM |SpaceGainComponentsAtCoolingPeakMonthly
| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |ComfortReportSimple55Monthly
| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |OccupantComfortDataSummaryMonthly
| DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 | BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 |ChillerReportMonthly
| COOLSYS1 CHILLER1 | COOLSYS1 CHILLER2 |TowerReportMonthly
| CENTRAL TOWER | TOWERWATERSYS COOLTOWER 1 | TOWERWATERSYS COOLTOWER 2 |BoilerReportMonthly
| HEATSYS1 BOILER | CENTRAL BOILER |DXReportMonthly
| VAV_BOT WITH REHEAT COOLING COIL | VAV_MID WITH REHEAT COOLING COIL | VAV_TOP WITH REHEAT COOLING COIL | CAV_BAS COOLING COIL | AIRLOOP DATACENTER BASEMENT COOLING COIL | AIRLOOP DATACENTER BOT COOLING COIL | AIRLOOP DATACENTER MID COOLING COIL | AIRLOOP DATACENTER TOP COOLING COIL |WindowReportMonthly
| PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW |WindowEnergyReportMonthly
| PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW |WindowZoneSummaryMonthly
| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |WindowEnergyZoneSummaryMonthly
| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWHSYS1 WATER HEATER |DaylightingReportMonthly
| PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_4_DAYLCTRL |CoilReportMonthly
| VAV_BOT WITH REHEAT HEATING COIL | CORE_BOTTOM VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | VAV_MID WITH REHEAT HEATING COIL | CORE_MID VAV BOX REHEAT COIL | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | VAV_TOP WITH REHEAT HEATING COIL | CORE_TOP VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | CAV_BAS HEATING COIL | AIRLOOP DATACENTER BASEMENT HEATING COIL | AIRLOOP DATACENTER BOT HEATING COIL | AIRLOOP DATACENTER MID HEATING COIL | AIRLOOP DATACENTER TOP HEATING COIL | AIRLOOP DATACENTER BASEMENT_SUPPHEATCOIL | AIRLOOP DATACENTER BOT_SUPPHEATCOIL | AIRLOOP DATACENTER MID_SUPPHEATCOIL | AIRLOOP DATACENTER TOP_SUPPHEATCOIL | VAV_BOT WITH REHEAT COOLING COIL | VAV_MID WITH REHEAT COOLING COIL | VAV_TOP WITH REHEAT COOLING COIL | CAV_BAS COOLING COIL | AIRLOOP DATACENTER BASEMENT COOLING COIL | AIRLOOP DATACENTER BOT COOLING COIL | AIRLOOP DATACENTER MID COOLING COIL | AIRLOOP DATACENTER TOP COOLING COIL |PlantLoopDemandReportMonthly
| HEATSYS1 | COOLSYS1_SUPPLY | COOLSYS1_DEMAND | SINGLE WATER PLANT LOOP | SWHSYS1 | TOWERWATERSYS |FanReportMonthly
| CAV_BAS FAN | VAV_BOT WITH REHEAT FAN | VAV_MID WITH REHEAT FAN | VAV_TOP WITH REHEAT FAN | AIRLOOP DATACENTER BASEMENT SUPPLY FAN | AIRLOOP DATACENTER BOT SUPPLY FAN | AIRLOOP DATACENTER MID SUPPLY FAN | AIRLOOP DATACENTER TOP SUPPLY FAN |PumpReportMonthly
| HEATSYS1 PUMP | COOLSYS1 PUMP SECONDARY | COOLSYS1 PUMP | PLANT CIRC PUMP | SWHSYS1 PUMP | TOWERWATERSYS PUMP |CondLoopDemandReportMonthly
| HEATSYS1 | COOLSYS1_SUPPLY | COOLSYS1_DEMAND | SINGLE WATER PLANT LOOP | SWHSYS1 | TOWERWATERSYS |ZoneTemperatureOscillationReportMonthly
| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |AirLoopSystemEnergyAndWaterUseMonthly
| VAV_BOT WITH REHEAT | VAV_MID WITH REHEAT | VAV_TOP WITH REHEAT | CAV_BAS | AIRLOOP DATACENTER BASEMENT | AIRLOOP DATACENTER BOT | AIRLOOP DATACENTER MID | AIRLOOP DATACENTER TOP |AirLoopSystemComponentLoadsMonthly
| VAV_BOT WITH REHEAT | VAV_MID WITH REHEAT | VAV_TOP WITH REHEAT | CAV_BAS | AIRLOOP DATACENTER BASEMENT | AIRLOOP DATACENTER BOT | AIRLOOP DATACENTER MID | AIRLOOP DATACENTER TOP |AirLoopSystemComponentEnergyUseMonthly
| VAV_BOT WITH REHEAT | VAV_MID WITH REHEAT | VAV_TOP WITH REHEAT | CAV_BAS | AIRLOOP DATACENTER BASEMENT | AIRLOOP DATACENTER BOT | AIRLOOP DATACENTER MID | AIRLOOP DATACENTER TOP |MechanicalVentilationLoadsMonthly
| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
GeneralValue | |
Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:03 |
RunPeriod | RUNPERIOD 1 |
Weather File | International Falls Intl Ap MN USA TMY3 WMO#=727470 |
Latitude [deg] | 48.57 |
Longitude [deg] | -93.4 |
Elevation [m] | 359.00 |
Time Zone | -6.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 12183.89 | 3655.17 | 2436.78 | 3655.17 | 2436.78 |
Above Ground Wall Area [m2] | 11589.54 | 3476.86 | 2317.91 | 3476.86 | 2317.91 |
Window Opening Area [m2] | 3476.85 | 1043.06 | 695.37 | 1043.06 | 695.37 |
Gross Window-Wall Ratio [%] | 28.54 | 28.54 | 28.54 | 28.54 | 28.54 |
Above Ground Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 12183.89 | 3655.17 | 2436.78 | 3655.17 | 2436.78 |
Above Ground Wall Area [m2] | 11589.54 | 3476.86 | 2317.91 | 3476.86 | 2317.91 |
Window Opening Area [m2] | 3476.85 | 1043.06 | 695.37 | 1043.06 | 695.37 |
Gross Window-Wall Ratio [%] | 28.54 | 28.54 | 28.54 | 28.54 | 28.54 |
Above Ground Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | |
Gross Roof Area [m2] | 3563.11 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
BASEMENT | 2779.43 | Yes | Yes | 6779.02 | 1.00 | 0.00 | 397.05 | 0.00 | 0.00 | 9.3279 | 18.58 | 4.8418 |
CORE_BOTTOM | 2496.12 | Yes | Yes | 6849.35 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.3279 | 18.58 | 8.0697 |
CORE_MID | 2496.12 | Yes | Yes | 6849.35 | 10.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.3279 | 18.58 | 8.0696 |
CORE_TOP | 2496.12 | Yes | Yes | 6849.35 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.3279 | 18.58 | 8.0696 |
PERIMETER_BOT_ZN_3 | 313.41 | Yes | Yes | 860.00 | 1.00 | 200.61 | 0.00 | 86.92 | 86.92 | 9.3279 | 18.58 | 8.0700 |
PERIMETER_BOT_ZN_2 | 201.98 | Yes | Yes | 554.22 | 1.00 | 133.74 | 0.00 | 57.95 | 57.95 | 9.3279 | 18.58 | 8.0700 |
PERIMETER_BOT_ZN_1 | 313.42 | Yes | Yes | 860.02 | 1.00 | 200.61 | 0.00 | 86.92 | 86.92 | 9.3279 | 18.58 | 8.0699 |
PERIMETER_BOT_ZN_4 | 201.98 | Yes | Yes | 554.22 | 1.00 | 133.74 | 0.00 | 57.95 | 57.95 | 9.3279 | 18.58 | 8.0699 |
PERIMETER_MID_ZN_3 | 313.41 | Yes | Yes | 860.00 | 10.00 | 200.61 | 0.00 | 86.92 | 86.92 | 9.3279 | 18.58 | 8.0700 |
PERIMETER_MID_ZN_2 | 201.98 | Yes | Yes | 554.22 | 10.00 | 133.74 | 0.00 | 57.95 | 57.95 | 9.3279 | 18.58 | 8.0700 |
PERIMETER_MID_ZN_1 | 313.42 | Yes | Yes | 860.02 | 10.00 | 200.61 | 0.00 | 86.92 | 86.92 | 9.3279 | 18.58 | 8.0699 |
PERIMETER_MID_ZN_4 | 201.98 | Yes | Yes | 554.22 | 10.00 | 133.74 | 0.00 | 57.95 | 57.95 | 9.3279 | 18.58 | 8.0699 |
PERIMETER_TOP_ZN_3 | 313.41 | Yes | Yes | 860.00 | 1.00 | 200.61 | 0.00 | 86.92 | 86.92 | 9.3279 | 18.58 | 8.0700 |
PERIMETER_TOP_ZN_2 | 201.98 | Yes | Yes | 554.22 | 1.00 | 133.74 | 0.00 | 57.95 | 57.95 | 9.3279 | 18.58 | 8.0700 |
PERIMETER_TOP_ZN_1 | 313.42 | Yes | Yes | 860.02 | 1.00 | 200.61 | 0.00 | 86.92 | 86.92 | 9.3279 | 18.58 | 8.0699 |
PERIMETER_TOP_ZN_4 | 201.98 | Yes | Yes | 554.22 | 1.00 | 133.74 | 0.00 | 57.95 | 57.95 | 9.3279 | 18.58 | 8.0699 |
GROUNDFLOOR_PLENUM | 3563.11 | Yes | No | 4344.14 | 1.00 | 297.11 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
MIDFLOOR_PLENUM | 3563.11 | Yes | No | 4344.14 | 10.00 | 297.11 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
TOPFLOOR_PLENUM | 3563.11 | Yes | No | 4344.14 | 1.00 | 297.11 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
DATACENTER_BOT_ZN_6 | 36.20 | Yes | Yes | 99.34 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.0861 | 18.58 | 215.2992 |
DATACENTER_MID_ZN_6 | 36.20 | Yes | Yes | 99.34 | 10.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.0861 | 18.58 | 215.2992 |
DATACENTER_TOP_ZN_6 | 36.20 | Yes | Yes | 99.34 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.0861 | 18.58 | 215.2992 |
DATACENTER_BASEMENT_ZN_6 | 783.68 | Yes | Yes | 1911.37 | 1.00 | 0.00 | 197.31 | 0.00 | 0.00 | 9.3279 | 18.58 | 484.4232 |
Total | 46320.38 | 126016.35 | 8024.24 | 594.36 | 3476.85 | 3476.85 | 9.3913 | 18.58 | 17.8789 | |||
Conditioned Total | 46320.38 | 126016.35 | 8024.24 | 594.36 | 3476.85 | 3476.85 | 9.3913 | 18.58 | 17.8789 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 42757.27 | 52129.67 | 3565.29 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
BASEMENT | 2779.43 | Yes | Yes | 1.00 | BASEMENT | GENERAL | BASEMENT | 9.3279 | 18.58 | 4.8418 | |
CORE_BOTTOM | 2496.12 | Yes | Yes | 1.00 | CORE_BOTTOM | GENERAL | CORE_BOTTOM | 9.3279 | 18.58 | 8.0697 | |
CORE_MID | 2496.12 | Yes | Yes | 10.00 | CORE_MID | GENERAL | CORE_MID | 9.3279 | 18.58 | 8.0696 | |
CORE_TOP | 2496.12 | Yes | Yes | 1.00 | CORE_TOP | GENERAL | CORE_TOP | 9.3279 | 18.58 | 8.0696 | |
PERIMETER_BOT_ZN_3 | 313.41 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_3 | GENERAL | PERIMETER_BOT_ZN_3 | 9.3279 | 18.58 | 8.0700 | |
PERIMETER_BOT_ZN_2 | 201.98 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_2 | GENERAL | PERIMETER_BOT_ZN_2 | 9.3279 | 18.58 | 8.0700 | |
PERIMETER_BOT_ZN_1 | 313.42 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_1 | GENERAL | PERIMETER_BOT_ZN_1 | 9.3279 | 18.58 | 8.0699 | |
PERIMETER_BOT_ZN_4 | 201.98 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_4 | GENERAL | PERIMETER_BOT_ZN_4 | 9.3279 | 18.58 | 8.0699 | |
PERIMETER_MID_ZN_3 | 313.41 | Yes | Yes | 10.00 | PERIMETER_MID_ZN_3 | GENERAL | PERIMETER_MID_ZN_3 | 9.3279 | 18.58 | 8.0700 | |
PERIMETER_MID_ZN_2 | 201.98 | Yes | Yes | 10.00 | PERIMETER_MID_ZN_2 | GENERAL | PERIMETER_MID_ZN_2 | 9.3279 | 18.58 | 8.0700 | |
PERIMETER_MID_ZN_1 | 313.42 | Yes | Yes | 10.00 | PERIMETER_MID_ZN_1 | GENERAL | PERIMETER_MID_ZN_1 | 9.3279 | 18.58 | 8.0699 | |
PERIMETER_MID_ZN_4 | 201.98 | Yes | Yes | 10.00 | PERIMETER_MID_ZN_4 | GENERAL | PERIMETER_MID_ZN_4 | 9.3279 | 18.58 | 8.0699 | |
PERIMETER_TOP_ZN_3 | 313.41 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_3 | GENERAL | PERIMETER_TOP_ZN_3 | 9.3279 | 18.58 | 8.0700 | |
PERIMETER_TOP_ZN_2 | 201.98 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_2 | GENERAL | PERIMETER_TOP_ZN_2 | 9.3279 | 18.58 | 8.0700 | |
PERIMETER_TOP_ZN_1 | 313.42 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_1 | GENERAL | PERIMETER_TOP_ZN_1 | 9.3279 | 18.58 | 8.0699 | |
PERIMETER_TOP_ZN_4 | 201.98 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_4 | GENERAL | PERIMETER_TOP_ZN_4 | 9.3279 | 18.58 | 8.0699 | |
GROUNDFLOOR_PLENUM | 3563.11 | Yes | No | 1.00 | GROUNDFLOOR_PLENUM | GENERAL | GROUNDFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
MIDFLOOR_PLENUM | 3563.11 | Yes | No | 10.00 | MIDFLOOR_PLENUM | GENERAL | MIDFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
TOPFLOOR_PLENUM | 3563.11 | Yes | No | 1.00 | TOPFLOOR_PLENUM | GENERAL | TOPFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
DATACENTER_BOT_ZN_6 | 36.20 | Yes | Yes | 1.00 | DATACENTER_BOT_ZN_6 | GENERAL | DATACENTER_BOT_ZN_6 | 16.0861 | 18.58 | 215.2992 | |
DATACENTER_MID_ZN_6 | 36.20 | Yes | Yes | 10.00 | DATACENTER_MID_ZN_6 | GENERAL | DATACENTER_MID_ZN_6 | 16.0861 | 18.58 | 215.2992 | |
DATACENTER_TOP_ZN_6 | 36.20 | Yes | Yes | 1.00 | DATACENTER_TOP_ZN_6 | GENERAL | DATACENTER_TOP_ZN_6 | 16.0861 | 18.58 | 215.2992 | |
DATACENTER_BASEMENT_ZN_6 | 783.68 | Yes | Yes | 1.00 | DATACENTER_BASEMENT_ZN_6 | GENERAL | DATACENTER_BASEMENT_ZN_6 | 9.3279 | 18.58 | 484.4232 | |
Total | 46320.38 | 9.3913 | 9.29 | 17.8789 | |||||||
Conditioned Total | 46320.38 | 9.3913 | 9.29 | 17.8789 | |||||||
Unconditioned Total | 0.00 | 0.0000 | 0.00 | 0.0000 | |||||||
Not Part of Total | 42757.27 | 0.0000 | 0.00 | 0.0000 |
Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
GENERAL | 46320.38 | 46320.38 | 0.00 | 42757.27 | 2.8860 | 60.38 | 10.8345 |
Total | 46320.38 | 46320.38 | 0.00 | 42757.27 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
End UsesElectricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 08-AUG-15:20 | 09-JAN-07:10 | - | - | - | - | - | - | - | - | - | - | 18-MAY-15:09 |
Heating | 0.00 | 3353627.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 437820.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 316816.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 794004.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 84885.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 269639.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 61682.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 87722.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 6524.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 29377.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 2059095.48 | 3383004.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler | 0.00 | 3353627.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 437820.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 316816.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 320838.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
DataCenterPlugLoads | 473165.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 5451.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 79171.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 263.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Fans | General | 269639.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 61682.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 87722.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 6524.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Water Heater | 0.00 | 29377.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 4222.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 9324.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 11749.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 2130.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 48180.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 6150.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 7940.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 1591.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 2287.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 98.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 178.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 884.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 89632.47 | 5107.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 91.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 201.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 253.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 46.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1040.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 132.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 171.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 34.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 49.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 2.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 3.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 19.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1935.05 | 110.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 91.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 201.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 253.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 46.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1040.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 132.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 171.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 34.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 49.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 2.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 3.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 19.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1935.05 | 110.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
AirTerminal:SingleDuct:ConstantVolume:NoReheatDesign Size Maximum Air Flow Rate [m3/s] | |
BASEMENT DIRECT AIR | 5.91 |
DATACENTER_BOT_ZN_6 DIRECT AIR | 0.524438 |
DATACENTER_MID_ZN_6 DIRECT AIR | 5.03 |
DATACENTER_TOP_ZN_6 DIRECT AIR | 0.509870 |
DATACENTER_BASEMENT_ZN_6 DIRECT AIR | 22.28 |
Design Size Maximum Air Flow Rate [m3/s] | Design Size Constant Minimum Air Flow Fraction | User-Specified Constant Minimum Air Flow Fraction | Design Size Minimum Air Flow Rate [m3/s] | Design Size Maximum Flow Fraction during Reheat [] | User-Specified Maximum Flow Fraction during Reheat [] | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | Design Size Maximum Reheat Water Flow Rate [m3/s] | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | |
CORE_BOTTOM VAV BOX COMPONENT | 6.19 | 0.307418 | 0.316000 | 1.96 | 0.819780 | 0.500000 | 0.001239 | 0.000251 | 1.96 | 12.80 | 0.008000 |
CORE_MID VAV BOX COMPONENT | 58.11 | 0.327300 | 0.330000 | 19.18 | 0.872801 | 0.500000 | 0.001164 | 0.004778 | 19.18 | 12.80 | 0.008000 |
CORE_TOP VAV BOX COMPONENT | 5.71 | 0.332837 | 0.342000 | 1.95 | 0.887565 | 0.500000 | 0.001145 | 0.001007 | 3.58 | 12.80 | 0.008000 |
PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | 0.968315 | 0.246635 | 0.300000 | 0.290495 | 0.657694 | 0.500000 | 0.001545 | 0.000175 | 0.622329 | 12.80 | 0.008000 |
PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | 1.29 | 0.119291 | 0.300000 | 0.387048 | 0.318110 | 0.500000 | 0.003194 | 0.000120 | 0.426975 | 12.80 | 0.008000 |
PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | 1.60 | 0.149389 | 0.300000 | 0.479606 | 0.398370 | 0.500000 | 0.002550 | 0.000192 | 0.683114 | 12.80 | 0.008000 |
PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | 1.56 | 0.098538 | 0.300000 | 0.468565 | 0.300000 | 0.500000 | 0.003867 | 0.000109 | 0.468565 | 12.80 | 0.008000 |
PERIMETER_MID_ZN_3 VAV BOX COMPONENT | 9.01 | 0.264950 | 0.300000 | 2.70 | 0.706535 | 0.500000 | 0.001438 | 0.002512 | 8.94 | 12.80 | 0.008000 |
PERIMETER_MID_ZN_2 VAV BOX COMPONENT | 13.55 | 0.113621 | 0.300000 | 4.06 | 0.302990 | 0.500000 | 0.003353 | 0.001666 | 5.93 | 12.80 | 0.008000 |
PERIMETER_MID_ZN_1 VAV BOX COMPONENT | 16.18 | 0.147644 | 0.300000 | 4.85 | 0.393718 | 0.500000 | 0.002581 | 0.002537 | 9.03 | 12.80 | 0.008000 |
PERIMETER_MID_ZN_4 VAV BOX COMPONENT | 14.27 | 0.107859 | 0.300000 | 4.28 | 0.300000 | 0.500000 | 0.003532 | 0.001629 | 5.80 | 12.80 | 0.008000 |
PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | 1.18 | 0.201558 | 0.300000 | 0.355462 | 0.537488 | 0.500000 | 0.001890 | 0.000333 | 1.18 | 12.80 | 0.008000 |
PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | 1.35 | 0.113709 | 0.300000 | 0.406050 | 0.303224 | 0.500000 | 0.003351 | 0.000220 | 0.781804 | 12.80 | 0.008000 |
PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | 1.71 | 0.139345 | 0.300000 | 0.514175 | 0.371587 | 0.500000 | 0.002734 | 0.000336 | 1.20 | 12.80 | 0.008000 |
PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | 1.50 | 0.102804 | 0.300000 | 0.449124 | 0.300000 | 0.500000 | 0.003706 | 0.000219 | 0.778868 | 12.80 | 0.008000 |
Design Size Rated Capacity [W] | Design Size Maximum Water Flow Rate [m3/s] | Design Size U-Factor Times Area Value [W/K] | |
CORE_BOTTOM VAV BOX REHEAT COIL | 28719.18 | 0.000251 | 610.38 |
CORE_MID VAV BOX REHEAT COIL | 546187.57 | 0.004778 | 13699.22 |
CORE_TOP VAV BOX REHEAT COIL | 115129.54 | 0.001007 | 3038.05 |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | 19997.96 | 0.000175 | 527.45 |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | 13718.59 | 0.000120 | 361.81 |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | 21947.42 | 0.000192 | 578.82 |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | 12469.38 | 0.000109 | 305.19 |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | 287082.78 | 0.002512 | 7569.30 |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | 190404.41 | 0.001666 | 5020.15 |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | 290029.29 | 0.002537 | 7646.94 |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | 186173.95 | 0.001629 | 4908.67 |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | 38033.07 | 0.000333 | 1002.63 |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | 25094.30 | 0.000220 | 661.53 |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | 38414.88 | 0.000336 | 1012.69 |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | 25000.02 | 0.000219 | 659.04 |
VAV_BOT WITH REHEAT HEATING COIL | 129814.53 | 0.001136 | 1867.90 |
VAV_MID WITH REHEAT HEATING COIL | 1312673.62 | 0.011484 | 18441.22 |
VAV_TOP WITH REHEAT HEATING COIL | 131950.32 | 0.001154 | 1886.54 |
CAV_BAS HEATING COIL | 319601.40 | 0.002796 | 6737.17 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
VAV_BOT WITH REHEAT | 5.80 | 3.58 | 11.61 | 3.58 | 10.11 | 10.11 | 0.300000 | 0.354188 | 10.11 |
VAV_MID WITH REHEAT | 55.56 | 35.08 | 111.12 | 45.65 | 93.88 | 93.88 | 0.300000 | 0.486274 | 93.88 |
VAV_TOP WITH REHEAT | 5.73 | 3.68 | 11.46 | 7.52 | 10.04 | 10.04 | 0.300000 | 0.748866 | 10.04 |
CAV_BAS | 5.91 | 5.91 | 5.91 | 5.91 | 5.91 | 5.91 | 1.00 | 1.00 | 5.91 |
AIRLOOP DATACENTER BASEMENT | 22.28 | 22.28 | 22.28 | 22.28 | 22.28 | 22.28 | 1.00 | 0.999992 | 22.28 |
AIRLOOP DATACENTER BOT | 0.524438 | 0.524438 | 0.524438 | 0.524438 | 0.524438 | 0.524438 | 1.00 | 1.00 | 0.524438 |
AIRLOOP DATACENTER MID | 5.03 | 5.03 | 5.03 | 5.03 | 5.03 | 5.03 | 1.00 | 1.00 | 5.03 |
AIRLOOP DATACENTER TOP | 0.509870 | 0.509870 | 0.509870 | 0.509870 | 0.509870 | 0.509870 | 1.00 | 1.00 | 0.509870 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
VAV_BOT WITH REHEAT_OA_CONTROLLER | 10.11 | 2.54 |
VAV_MID WITH REHEAT_OA_CONTROLLER | 93.88 | 25.38 |
VAV_TOP WITH REHEAT_OA_CONTROLLER | 10.04 | 2.54 |
CAV_BAS_OA_CONTROLLER | 5.91 | 1.20 |
AIRLOOP DATACENTER BASEMENT_OA_CONTROLLER | 22.28 | 0.338393 |
AIRLOOP DATACENTER BOT_OA_CONTROLLER | 0.524438 | 0.015632 |
AIRLOOP DATACENTER MID_OA_CONTROLLER | 5.03 | 0.156323 |
AIRLOOP DATACENTER TOP_OA_CONTROLLER | 0.509870 | 0.015632 |
Design Size Nominal Supply Air Flow Rate [m3/s] | |
VAV_BOT WITH REHEAT OA HEAT RECOVERY | 2.54 |
VAV_MID WITH REHEAT OA HEAT RECOVERY | 25.38 |
VAV_TOP WITH REHEAT OA HEAT RECOVERY | 2.54 |
CAV_BAS OA HEAT RECOVERY | 1.20 |
Design Size Design Inlet Air Temperature [C] | Design Size Design Inlet Water Temperature [C] | Design Size Design Outlet Air Temperature [C] | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | Design Size Design Coil Load [W] | Design Size Design Water Flow Rate [m3/s] | Design Size Design Air Flow Rate [m3/s] | |
VAV_BOT WITH REHEAT COOLING COIL | 25.58 | 6.67 | 10.88 | 0.009868 | 0.008500 | 215745.21 | 0.009178 | 10.11 |
VAV_MID WITH REHEAT COOLING COIL | 25.73 | 6.67 | 10.87 | 0.010024 | 0.008500 | 2064211.47 | 0.087816 | 93.88 |
VAV_TOP WITH REHEAT COOLING COIL | 25.54 | 6.67 | 10.88 | 0.009884 | 0.008500 | 214361.48 | 0.009119 | 10.04 |
CAV_BAS COOLING COIL | 25.25 | 6.67 | 11.36 | 0.009844 | 0.008500 | 120013.43 | 0.005106 | 5.91 |
Design Size Maximum Flow Rate [m3/s] | |
VAV_BOT WITH REHEAT FAN | 10.11 |
VAV_MID WITH REHEAT FAN | 93.88 |
VAV_TOP WITH REHEAT FAN | 10.04 |
Maximum Actuated Flow [m3/s] | Controller Convergence Tolerance | |
VAV_BOT WITH REHEAT_COOLC_CONTROLLER | 0.009178 | 0.000052 |
VAV_BOT WITH REHEAT_HEATC_CONTROLLER | 0.001136 | |
VAV_MID WITH REHEAT_COOLC_CONTROLLER | 0.087816 | 0.000005 |
VAV_MID WITH REHEAT_HEATC_CONTROLLER | 0.011484 | |
VAV_TOP WITH REHEAT_COOLC_CONTROLLER | 0.009119 | 0.000052 |
VAV_TOP WITH REHEAT_HEATC_CONTROLLER | 0.001154 | |
CAV_BAS_COOLC_CONTROLLER | 0.005106 | 0.000093 |
CAV_BAS_HEATC_CONTROLLER | 0.002796 |
Design Size Maximum Flow Rate [m3/s] | |
CAV_BAS FAN | 5.91 |
Design Size Rated Air Flow Rate [m3/s] | Design Size Rated Total Cooling Capacity [W] | Design Size Rated Sensible Cooling Capacity [W] | Design Size Rated Water Flow Rate [m3/s] | |
AIRLOOP DATACENTER BASEMENT COOLING COIL | 22.28 | 436569.56 | 301670.86 | 0.010692 |
AIRLOOP DATACENTER BOT COOLING COIL | 0.524438 | 10097.06 | 7032.30 | 0.000247 |
AIRLOOP DATACENTER MID COOLING COIL | 5.03 | 96893.41 | 67443.17 | 0.002373 |
AIRLOOP DATACENTER TOP COOLING COIL | 0.509870 | 9826.64 | 6840.10 | 0.000241 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Supplemental Heating Coil Nominal Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
AIRLOOP DATACENTER BASEMENT DXAC HEAT PUMP | 22.28 | 22.28 | 22.28 | 22.28 | 436569.56 | 436569.56 | 28525.81 | 1.00 |
AIRLOOP DATACENTER BOT DXAC HEAT PUMP | 0.524438 | 0.524438 | 0.524438 | 0.524438 | 10097.06 | 10097.06 | 1317.77 | 1.00 |
AIRLOOP DATACENTER MID DXAC HEAT PUMP | 5.03 | 5.03 | 5.03 | 5.03 | 96893.41 | 96893.41 | 13177.74 | 1.00 |
AIRLOOP DATACENTER TOP DXAC HEAT PUMP | 0.509870 | 0.509870 | 0.509870 | 0.509870 | 9826.64 | 9826.64 | 1317.77 | 1.00 |
Design Size Maximum Flow Rate [m3/s] | |
AIRLOOP DATACENTER BASEMENT SUPPLY FAN | 22.28 |
AIRLOOP DATACENTER BOT SUPPLY FAN | 0.524438 |
AIRLOOP DATACENTER MID SUPPLY FAN | 5.03 |
AIRLOOP DATACENTER TOP SUPPLY FAN | 0.509870 |
Design Size Rated Air Flow Rate [m3/s] | Design Size Rated Heating Capacity [W] | Design Size Rated Water Flow Rate [m3/s] | |
AIRLOOP DATACENTER BASEMENT HEATING COIL | 22.28 | 436569.56 | 0.010692 |
AIRLOOP DATACENTER BOT HEATING COIL | 0.524438 | 10097.06 | 0.000247 |
AIRLOOP DATACENTER MID HEATING COIL | 5.03 | 96893.41 | 0.002373 |
AIRLOOP DATACENTER TOP HEATING COIL | 0.509870 | 9826.64 | 0.000241 |
Design Size Nominal Capacity [W] | |
AIRLOOP DATACENTER BASEMENT_SUPPHEATCOIL | 28525.81 |
AIRLOOP DATACENTER BOT_SUPPHEATCOIL | 1317.77 |
AIRLOOP DATACENTER MID_SUPPHEATCOIL | 13177.74 |
AIRLOOP DATACENTER TOP_SUPPHEATCOIL | 1317.77 |
Design Size Nominal Capacity Volume [m3/s] | User-Specified Nominal Capacity Volume [m3/s] | Design Size Rated Power [W] | User-Specified Rated Power [W] | |
DATACENTER_BASEMENT_ZN_6 HUMIDIFIER | 0.000206 | 0.000037 | 96450.70 | 100000.00 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | Design Minimum Flow Rate [m3/s] | |
COOLSYS1 PUMP SECONDARY | 0.111220 | 22918.26 | |
HEATSYS1 PUMP | 0.032653 | 9833.66 | 0.000000 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
COOLSYS1_DEMAND | 0.111220 | 13.35 |
HEATSYS1 | 0.032653 | 3.92 |
COOLSYS1_SUPPLY | 0.111220 | 13.35 |
SINGLE WATER PLANT LOOP | 0.013552 | 1.63 |
SWHSYS1 | 0.000440 | 0.052800 |
Loop Supply Side Design Fluid Flow Rate [m3/s] | Loop Demand Side Design Fluid Flow Rate [m3/s] | Heat Exchanger U-Factor Times Area Value [W/C] | Loop-to-loop Temperature Difference Used to Size Heat Exchanger U-Factor Times Area Value [C] | |
BYPASS HEAT EXCHANGER | 0.111220 | 0.111220 | 466844.93 | 5.60 |
Design Size Nominal Capacity [W] | User-Specified Nominal Capacity [W] | Design Size Design Water Flow Rate [m3/s] | |
HEATSYS1 BOILER | 3732442.20 | 3732442.20 | 0.032653 |
CENTRAL BOILER | 558242.85 | 547194.34 | 0.013552 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | |
COOLSYS1 PUMP | 0.111220 | 15867.08 |
PLANT CIRC PUMP | 0.013552 | 3456.54 |
SWHSYS1 PUMP | 0.000440 | 5.96 |
Design Size Reference Chilled Water Flow Rate [m3/s] | User-Specified Reference Chilled Water Flow Rate [m3/s] | Design Size Reference Capacity [W] | User-Specified Reference Capacity [W] | Design Size Reference Condenser Water Flow Rate [m3/s] | |
COOLSYS1 CHILLER1 | 0.111220 | 0.055910 | 1317449.36 | 1323676.83 | 0.065504 |
COOLSYS1 CHILLER2 | 0.111220 | 0.055910 | 1317449.36 | 1323676.83 | 0.065504 |
Design Water Flow Rate [m3/s] | Air Flow Rate at High Fan Speed [m3/s] | Fluid cooler UA value at high fan speed based on nominal capacity input [W/K] | Air Flow Rate at Low Fan Speed [m3/s] | Fan Power at Low Fan Speed [W] | U-factor Times Area Value at Low Fan Speed [W/C] | |
CENTRAL TOWER | 0.013552 | 139666.47 | 58281.61 | 69833.23 | 7879.72 | 21315.55 |
Use Side Design Flow Rate [m3/s] | |
SWHSYS1 WATER HEATER | 0.000440 |
Maximum Loop Flow Rate [m3/s] | Condenser Loop Volume [m3] | |
TOWERWATERSYS | 0.131008 | 15.72 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | |
TOWERWATERSYS PUMP | 0.131008 | 39456.67 |
Design Air Flow Rate [m3/s] | Nominal Capacity [W] | Air Flow Rate in free convection regime [m3/s] | Tower capacity in free convection regime at design conditions [W] | |
TOWERWATERSYS COOLTOWER 1 | 52.83 | 1571052.59 | 10.57 | 196381.57 |
TOWERWATERSYS COOLTOWER 2 | 52.83 | 1571052.59 | 10.57 | 196381.57 |
Design Water Flow Rate [m3/s] Equipment # 47 | |
WSHPPLANT OPERATION SCHEME | 0.068038 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
PERIMETER_BOT_ZN_3_WALL_NORTH | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR3 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR4 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | |
PERIMETER_BOT_ZN_2_WALL_EAST | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR1 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | |
PERIMETER_BOT_ZN_1_WALL_SOUTH | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR3 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR4 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | |
PERIMETER_BOT_ZN_4_WALL_WEST | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR1 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR2 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | |
PERIMETER_MID_ZN_3_WALL_NORTH | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | |
PERIMETER_MID_ZN_2_WALL_EAST | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | |
PERIMETER_MID_ZN_1_WALL_SOUTH | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | |
PERIMETER_MID_ZN_4_WALL_WEST | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | |
PERIMETER_TOP_ZN_3_WALL_NORTH | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | |
PERIMETER_TOP_ZN_2_WALL_EAST | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | |
PERIMETER_TOP_ZN_1_WALL_SOUTH | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | |
PERIMETER_TOP_ZN_4_WALL_WEST | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
VersionVersion ID | |
1 | 22.1.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 5.40 | -2.00 | -14.60 | -16.90 | -11.50 | -6.20 | 4.00 | 13.40 | 18.00 | 19.70 | 17.90 | 12.30 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | International Falls Intl Ap MN USA TMY3 WMO#=727470 | 48.57 | -93.40 | -6.00 | 359.00 | 97086 | 1.1539 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 3.29 | 36.60 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | OfficeLarge | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 23 | 221 | 36 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | BASEMENT | 0.0 | 0.00 | 0.00 | 0.00 | 44.59 | 24.37 | -1.22 | 1 | 1 | 1 | 16.08 | 73.11 | 0.00 | 48.74 | -2.44 | 0.00 | 2.44 | 6779.02 | TARP | TARP | 2779.43 | 0.00 | 0.00 | 0.00 | 9 | 0 | 0 | Yes |
2 | CORE_BOTTOM | 0.0 | 0.00 | 0.00 | 0.00 | 37.01 | 24.37 | 1.37 | 1 | 1 | 1 | 5.49 | 68.53 | 4.57 | 44.17 | 0.00 | 2.74 | 2.74 | 6849.35 | TARP | TARP | 2496.12 | 0.00 | 0.00 | 0.00 | 7 | 0 | 0 | Yes |
3 | CORE_MID | 0.0 | 0.00 | 0.00 | 0.00 | 37.01 | 24.37 | 18.14 | 1 | 10 | 1 | 5.49 | 68.53 | 4.57 | 44.17 | 16.77 | 19.51 | 2.74 | 6849.35 | TARP | TARP | 2496.12 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
4 | CORE_TOP | 0.0 | 0.00 | 0.00 | 0.00 | 37.01 | 24.37 | 34.91 | 1 | 1 | 1 | 5.49 | 68.53 | 4.57 | 44.17 | 33.54 | 36.28 | 2.74 | 6849.35 | TARP | TARP | 2496.12 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
5 | PERIMETER_BOT_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 36.55 | 46.54 | 1.37 | 1 | 1 | 1 | 0.00 | 73.11 | 44.17 | 48.74 | 0.00 | 2.74 | 2.74 | 860.00 | TARP | TARP | 313.41 | 200.61 | 105.88 | 86.92 | 8 | 9 | 0 | Yes |
6 | PERIMETER_BOT_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 70.95 | 24.37 | 1.37 | 1 | 1 | 1 | 68.53 | 73.11 | 0.00 | 48.74 | 0.00 | 2.74 | 2.74 | 554.22 | TARP | TARP | 201.98 | 133.74 | 71.89 | 57.95 | 6 | 5 | 0 | Yes |
7 | PERIMETER_BOT_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 36.55 | 2.20 | 1.37 | 1 | 1 | 1 | 0.00 | 73.11 | 0.00 | 4.57 | 0.00 | 2.74 | 2.74 | 860.02 | TARP | TARP | 313.42 | 200.61 | 105.88 | 86.92 | 8 | 9 | 0 | Yes |
8 | PERIMETER_BOT_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.16 | 24.37 | 1.37 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 48.74 | 0.00 | 2.74 | 2.74 | 554.22 | TARP | TARP | 201.98 | 133.74 | 71.89 | 57.95 | 6 | 5 | 0 | Yes |
9 | PERIMETER_MID_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 36.55 | 46.54 | 18.14 | 1 | 10 | 1 | 0.00 | 73.11 | 44.17 | 48.74 | 16.77 | 19.51 | 2.74 | 860.00 | TARP | TARP | 313.41 | 200.61 | 113.68 | 86.92 | 7 | 1 | 0 | Yes |
10 | PERIMETER_MID_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 70.95 | 24.37 | 18.14 | 1 | 10 | 1 | 68.53 | 73.11 | 0.00 | 48.74 | 16.77 | 19.51 | 2.74 | 554.22 | TARP | TARP | 201.98 | 133.74 | 75.79 | 57.95 | 6 | 1 | 0 | Yes |
11 | PERIMETER_MID_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 36.55 | 2.20 | 18.14 | 1 | 10 | 1 | 0.00 | 73.11 | 0.00 | 4.57 | 16.77 | 19.51 | 2.74 | 860.02 | TARP | TARP | 313.42 | 200.61 | 113.68 | 86.92 | 7 | 1 | 0 | Yes |
12 | PERIMETER_MID_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.16 | 24.37 | 18.14 | 1 | 10 | 1 | 0.00 | 4.57 | 0.00 | 48.74 | 16.77 | 19.51 | 2.74 | 554.22 | TARP | TARP | 201.98 | 133.74 | 75.79 | 57.95 | 6 | 1 | 0 | Yes |
13 | PERIMETER_TOP_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 36.55 | 46.54 | 34.91 | 1 | 1 | 1 | 0.00 | 73.11 | 44.17 | 48.74 | 33.54 | 36.28 | 2.74 | 860.00 | TARP | TARP | 313.41 | 200.61 | 113.68 | 86.92 | 7 | 1 | 0 | Yes |
14 | PERIMETER_TOP_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 70.95 | 24.37 | 34.91 | 1 | 1 | 1 | 68.53 | 73.11 | 0.00 | 48.74 | 33.54 | 36.28 | 2.74 | 554.22 | TARP | TARP | 201.98 | 133.74 | 75.79 | 57.95 | 6 | 1 | 0 | Yes |
15 | PERIMETER_TOP_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 36.55 | 2.20 | 34.91 | 1 | 1 | 1 | 0.00 | 73.11 | 0.00 | 4.57 | 33.54 | 36.28 | 2.74 | 860.02 | TARP | TARP | 313.42 | 200.61 | 113.68 | 86.92 | 7 | 1 | 0 | Yes |
16 | PERIMETER_TOP_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.16 | 24.37 | 34.91 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 48.74 | 33.54 | 36.28 | 2.74 | 554.22 | TARP | TARP | 201.98 | 133.74 | 75.79 | 57.95 | 6 | 1 | 0 | Yes |
17 | GROUNDFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 36.55 | 24.37 | 3.35 | 1 | 1 | 1 | 0.00 | 73.11 | 0.00 | 48.74 | 2.74 | 3.96 | 1.22 | 4344.14 | TARP | TARP | 3563.11 | 297.11 | 297.11 | 0.00 | 11 | 0 | 0 | No |
18 | MIDFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 36.55 | 24.37 | 20.12 | 1 | 10 | 1 | 0.00 | 73.11 | 0.00 | 48.74 | 19.51 | 20.73 | 1.22 | 4344.14 | TARP | TARP | 3563.11 | 297.11 | 297.11 | 0.00 | 11 | 0 | 0 | No |
19 | TOPFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 36.55 | 24.37 | 36.89 | 1 | 1 | 1 | 0.00 | 73.11 | 0.00 | 48.74 | 36.28 | 37.50 | 1.22 | 4344.14 | TARP | TARP | 3563.11 | 297.11 | 297.11 | 0.00 | 11 | 0 | 0 | No |
20 | DATACENTER_BOT_ZN_6 | 0.0 | 5.49 | 44.17 | 0.00 | 5.03 | 24.37 | 1.37 | 1 | 1 | 1 | 4.57 | 5.49 | 4.57 | 44.17 | 0.00 | 2.74 | 2.74 | 99.34 | TARP | TARP | 36.20 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
21 | DATACENTER_MID_ZN_6 | 0.0 | 4.57 | 4.57 | 16.77 | 5.03 | 24.37 | 18.14 | 1 | 10 | 1 | 4.57 | 5.49 | 4.57 | 44.17 | 16.77 | 19.51 | 2.74 | 99.34 | TARP | TARP | 36.20 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
22 | DATACENTER_TOP_ZN_6 | 0.0 | 4.57 | 4.57 | 33.54 | 5.03 | 24.37 | 34.91 | 1 | 1 | 1 | 4.57 | 5.49 | 4.57 | 44.17 | 33.54 | 36.28 | 2.74 | 99.34 | TARP | TARP | 36.20 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
23 | DATACENTER_BASEMENT_ZN_6 | 0.0 | 16.08 | 0.00 | -2.44 | 8.04 | 24.37 | -1.22 | 1 | 1 | 1 | 0.00 | 16.08 | 0.00 | 48.74 | -2.44 | 0.00 | 2.44 | 1911.37 | TARP | TARP | 783.68 | 0.00 | 0.00 | 0.00 | 10 | 0 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | BASEMENT | 2779.43 | 149.6 | 18.579 | 5.382E-002 | 9.328 | 4.842 | 0.000 | 0.000 | 0.000 | 0.000 | 14.170 | No |
2 | CORE_BOTTOM | 2496.12 | 134.4 | 18.579 | 5.382E-002 | 9.328 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.398 | No |
3 | CORE_MID | 2496.12 | 134.4 | 18.579 | 5.382E-002 | 9.328 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.398 | No |
4 | CORE_TOP | 2496.12 | 134.4 | 18.579 | 5.382E-002 | 9.328 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.398 | No |
5 | PERIMETER_BOT_ZN_3 | 313.41 | 16.9 | 18.579 | 5.382E-002 | 9.328 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.398 | No |
6 | PERIMETER_BOT_ZN_2 | 201.98 | 10.9 | 18.579 | 5.382E-002 | 9.328 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.398 | No |
7 | PERIMETER_BOT_ZN_1 | 313.42 | 16.9 | 18.579 | 5.382E-002 | 9.328 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.398 | No |
8 | PERIMETER_BOT_ZN_4 | 201.98 | 10.9 | 18.579 | 5.382E-002 | 9.328 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.398 | No |
9 | PERIMETER_MID_ZN_3 | 313.41 | 16.9 | 18.579 | 5.382E-002 | 9.328 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.398 | No |
10 | PERIMETER_MID_ZN_2 | 201.98 | 10.9 | 18.579 | 5.382E-002 | 9.328 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.398 | No |
11 | PERIMETER_MID_ZN_1 | 313.42 | 16.9 | 18.579 | 5.382E-002 | 9.328 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.398 | No |
12 | PERIMETER_MID_ZN_4 | 201.98 | 10.9 | 18.579 | 5.382E-002 | 9.328 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.398 | No |
13 | PERIMETER_TOP_ZN_3 | 313.41 | 16.9 | 18.579 | 5.382E-002 | 9.328 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.398 | No |
14 | PERIMETER_TOP_ZN_2 | 201.98 | 10.9 | 18.579 | 5.382E-002 | 9.328 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.398 | No |
15 | PERIMETER_TOP_ZN_1 | 313.42 | 16.9 | 18.579 | 5.382E-002 | 9.328 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.398 | No |
16 | PERIMETER_TOP_ZN_4 | 201.98 | 10.9 | 18.579 | 5.382E-002 | 9.328 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 17.398 | No |
17 | GROUNDFLOOR_PLENUM | 3563.11 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
18 | MIDFLOOR_PLENUM | 3563.11 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
19 | TOPFLOOR_PLENUM | 3563.11 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
20 | DATACENTER_BOT_ZN_6 | 36.20 | 1.9 | 18.579 | 5.382E-002 | 16.086 | 215.299 | 0.000 | 0.000 | 0.000 | 0.000 | 231.385 | No |
21 | DATACENTER_MID_ZN_6 | 36.20 | 1.9 | 18.579 | 5.382E-002 | 16.086 | 215.299 | 0.000 | 0.000 | 0.000 | 0.000 | 231.385 | No |
22 | DATACENTER_TOP_ZN_6 | 36.20 | 1.9 | 18.579 | 5.382E-002 | 16.086 | 215.299 | 0.000 | 0.000 | 0.000 | 0.000 | 231.385 | No |
23 | DATACENTER_BASEMENT_ZN_6 | 783.68 | 42.2 | 18.579 | 5.382E-002 | 9.328 | 484.423 | 0.000 | 0.000 | 0.000 | 0.000 | 493.751 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | Cooling Effect Calculation | Ankle Draft Calculation | |
1 | DATACENTER_BOT_ZN_6 | BLDG_OCC_SCH_WO_SB | DATACENTER_BOT_ZN_6 | 36.20 | 1.9 | 1.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
2 | DATACENTER_MID_ZN_6 | BLDG_OCC_SCH_WO_SB | DATACENTER_MID_ZN_6 | 36.20 | 1.9 | 1.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
3 | DATACENTER_TOP_ZN_6 | BLDG_OCC_SCH_WO_SB | DATACENTER_TOP_ZN_6 | 36.20 | 1.9 | 1.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
4 | DATACENTER_BASEMENT_ZN_6 | BLDG_OCC_SCH_WO_SB | DATACENTER_BASEMENT_ZN_6 | 783.68 | 42.2 | 42.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 42 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
5 | BASEMENT | BLDG_OCC_SCH_WO_SB | BASEMENT | 2779.43 | 149.6 | 149.6 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 150 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
6 | CORE_BOTTOM | BLDG_OCC_SCH_WO_SB | CORE_BOTTOM | 2496.12 | 134.4 | 134.4 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 134 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
7 | CORE_MID | BLDG_OCC_SCH_WO_SB | CORE_MID | 2496.12 | 134.4 | 134.4 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 134 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
8 | CORE_TOP | BLDG_OCC_SCH_WO_SB | CORE_TOP | 2496.12 | 134.4 | 134.4 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 134 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
9 | PERIMETER_BOT_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_3 | 313.41 | 16.9 | 16.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
10 | PERIMETER_BOT_ZN_2 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_2 | 201.98 | 10.9 | 10.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
11 | PERIMETER_BOT_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_1 | 313.42 | 16.9 | 16.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
12 | PERIMETER_BOT_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_4 | 201.98 | 10.9 | 10.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
13 | PERIMETER_MID_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_3 | 313.41 | 16.9 | 16.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
14 | PERIMETER_MID_ZN_2 | BLDG_OCC_SCH_W_SB | PERIMETER_MID_ZN_2 | 201.98 | 10.9 | 10.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
15 | PERIMETER_MID_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_1 | 313.42 | 16.9 | 16.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
16 | PERIMETER_MID_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_4 | 201.98 | 10.9 | 10.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
17 | PERIMETER_TOP_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_3 | 313.41 | 16.9 | 16.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
18 | PERIMETER_TOP_ZN_2 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_2 | 201.98 | 10.9 | 10.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
19 | PERIMETER_TOP_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_1 | 313.42 | 16.9 | 16.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
20 | PERIMETER_TOP_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_4 | 201.98 | 10.9 | 10.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | BASEMENT_LIGHTS | LTG_SCH_OFFICE | BASEMENT | 2779.43 | 149.6 | 25926.330 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 25926.330 |
2 | CORE_BOTTOM_LIGHTS | LTG_SCH_OFFICE | CORE_BOTTOM | 2496.12 | 134.4 | 23283.667 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 23283.667 |
3 | CORE_MID_LIGHTS | LTG_SCH_OFFICE | CORE_MID | 2496.12 | 134.4 | 23283.667 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 23283.667 |
4 | CORE_TOP_LIGHTS | LTG_SCH_OFFICE | CORE_TOP | 2496.12 | 134.4 | 23283.667 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 23283.667 |
5 | PERIMETER_BOT_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_3 | 313.41 | 16.9 | 2923.497 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2923.497 |
6 | PERIMETER_BOT_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_2 | 201.98 | 10.9 | 1884.012 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1884.012 |
7 | PERIMETER_BOT_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_1 | 313.42 | 16.9 | 2923.561 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2923.561 |
8 | PERIMETER_BOT_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_4 | 201.98 | 10.9 | 1884.012 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1884.012 |
9 | PERIMETER_MID_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_3 | 313.41 | 16.9 | 2923.497 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2923.497 |
10 | PERIMETER_MID_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_2 | 201.98 | 10.9 | 1884.012 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1884.012 |
11 | PERIMETER_MID_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_1 | 313.42 | 16.9 | 2923.561 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2923.561 |
12 | PERIMETER_MID_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_4 | 201.98 | 10.9 | 1884.012 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1884.012 |
13 | PERIMETER_TOP_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_3 | 313.41 | 16.9 | 2923.497 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2923.497 |
14 | PERIMETER_TOP_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_2 | 201.98 | 10.9 | 1884.012 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1884.012 |
15 | PERIMETER_TOP_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_1 | 313.42 | 16.9 | 2923.561 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2923.561 |
16 | PERIMETER_TOP_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_4 | 201.98 | 10.9 | 1884.012 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1884.012 |
17 | DATACENTER_BASEMENT_LIGHTS | LTG_SCH_OFFICE | DATACENTER_BASEMENT_ZN_6 | 783.68 | 42.2 | 7310.116 | 9.328 | 173.302 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 7310.116 |
18 | DATACENTER_BOT_LIGHTS | LTG_SCH_DATACENTER | DATACENTER_BOT_ZN_6 | 36.20 | 1.9 | 582.361 | 16.086 | 298.861 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 582.361 |
19 | DATACENTER_MID_LIGHTS | LTG_SCH_DATACENTER | DATACENTER_MID_ZN_6 | 36.20 | 1.9 | 582.361 | 16.086 | 298.861 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 582.361 |
20 | DATACENTER_TOP_LIGHTS | LTG_SCH_DATACENTER | DATACENTER_TOP_ZN_6 | 36.20 | 1.9 | 582.361 | 16.086 | 298.861 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 582.361 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | BASEMENT_MISCPLUG_EQUIP | ALWAYS_ON | BASEMENT | 2779.43 | 149.6 | 13457.544 | 4.842 | 89.956 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 13457.544 | 13457.544 |
2 | CORE_BOTTOM_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_BOTTOM | 2496.12 | 134.4 | 20142.877 | 8.070 | 149.925 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 20142.877 |
3 | CORE_MID_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_MID | 2496.12 | 134.4 | 20142.800 | 8.070 | 149.924 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 20142.800 |
4 | CORE_TOP_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_TOP | 2496.12 | 134.4 | 20142.800 | 8.070 | 149.924 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 20142.800 |
5 | PERIMETER_BOT_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_3 | 313.41 | 16.9 | 2529.242 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 2529.242 |
6 | PERIMETER_BOT_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_2 | 201.98 | 10.9 | 1629.940 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1629.940 |
7 | PERIMETER_BOT_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_1 | 313.42 | 16.9 | 2529.281 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 2529.281 |
8 | PERIMETER_BOT_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_4 | 201.98 | 10.9 | 1629.929 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1629.929 |
9 | PERIMETER_MID_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_3 | 313.41 | 16.9 | 2529.242 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 2529.242 |
10 | PERIMETER_MID_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_2 | 201.98 | 10.9 | 1629.940 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1629.940 |
11 | PERIMETER_MID_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_1 | 313.42 | 16.9 | 2529.281 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 2529.281 |
12 | PERIMETER_MID_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_4 | 201.98 | 10.9 | 1629.929 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1629.929 |
13 | PERIMETER_TOP_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_3 | 313.41 | 16.9 | 2529.242 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 2529.242 |
14 | PERIMETER_TOP_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_2 | 201.98 | 10.9 | 1629.940 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1629.940 |
15 | PERIMETER_TOP_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_1 | 313.42 | 16.9 | 2529.281 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 2529.281 |
16 | PERIMETER_TOP_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_4 | 201.98 | 10.9 | 1629.929 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1629.929 |
17 | DATACENTER_BASEMENT_MISCPLUG_EQUIP | DATACENTER_EQUIP_SCH | DATACENTER_BASEMENT_ZN_6 | 783.68 | 42.2 | 379632.522 | 484.423 | 9000.000 | 0.000 | 0.100 | 0.000 | 0.900 | DataCenterPlugLoads | 94908.130 | 379632.522 |
18 | DATACENTER_BOT_MISCPLUG_EQUIP | DATACENTER_EQUIP_SCH | DATACENTER_BOT_ZN_6 | 36.20 | 1.9 | 7794.422 | 215.299 | 4000.000 | 0.000 | 0.100 | 0.000 | 0.900 | DataCenterPlugLoads | 1948.606 | 7794.422 |
19 | DATACENTER_MID_MISCPLUG_EQUIP | DATACENTER_EQUIP_SCH | DATACENTER_MID_ZN_6 | 36.20 | 1.9 | 7794.422 | 215.299 | 4000.000 | 0.000 | 0.100 | 0.000 | 0.900 | DataCenterPlugLoads | 1948.606 | 7794.422 |
20 | DATACENTER_TOP_MISCPLUG_EQUIP | DATACENTER_EQUIP_SCH | DATACENTER_TOP_ZN_6 | 36.20 | 1.9 | 7794.422 | 215.299 | 4000.000 | 0.000 | 0.100 | 0.000 | 0.900 | DataCenterPlugLoads | 1948.606 | 7794.422 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | INTERIORFURNISHINGS | 2 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
3 | DROPCEILING | 4 | 1 | 3 | 0.167 | 4.488 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 7 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | EXT_SLAB_8IN_WITH_CARPET | 8 | 2 | 7 | 0.167 | 3.285 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
6 | INT_SLAB_FLOOR | 12 | 2 | 7 | 0.167 | 3.839 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | INT_SLAB_CEILING | 13 | 2 | 7 | 0.167 | 3.839 | 0.900 | 0.900 | 0.700 | 0.700 | VeryRough |
8 | NONRES_ROOF | 17 | 3 | 3 | 0.167 | 0.1625 | 0.900 | 0.900 | 0.700 | 0.700 | Rough |
9 | NONRES_EXT_WALL_GRD | 20 | 3 | 9 | 0.167 | 1.078 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
10 | NONRES_EXT_WALL_MID | 21 | 3 | 9 | 0.167 | 1.004 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
11 | NONRES_EXT_WALL_TOP | 22 | 3 | 9 | 0.167 | 1.410 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
12 | BASEMENT_WALL_EAST_CFACTOR | 39 | 2 | 7 | 0.167 | 0.3542 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | BASEMENT_WALL_SOUTH_CFACTOR | 40 | 2 | 7 | 0.167 | 0.3542 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | BASEMENT_WALL_NORTH_CFACTOR | 41 | 2 | 7 | 0.167 | 0.3542 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | DATACENTER_BASEMENT_ZN_6_WALL_NORTH_CFACTOR | 42 | 2 | 7 | 0.167 | 0.3542 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
16 | DATACENTER_BASEMENT_ZN_6_WALL_SOUTH_CFACTOR | 43 | 2 | 7 | 0.167 | 0.3542 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
17 | DATACENTER_BASEMENT_ZN_6_WALL_WEST_CFACTOR | 44 | 2 | 7 | 0.167 | 0.3542 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
2 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
3 | AC02 ACOUSTIC CEILING | 0.0127 | 0.057 | 288.000 | 1339.000 | 0.2228 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | 200MM NORMALWEIGHT CONCRETE FLOOR | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
7 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
8 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
9 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
10 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
11 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
12 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
13 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 6.093 |
14 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
15 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
16 | NONRES_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.7605 |
17 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
18 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
19 | NONRES_EXTERIOR_WALL_INSULATION_MID | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8287 |
20 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
21 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
22 | NONRES_EXTERIOR_WALL_INSULATION_TOP | 0.0000 | 0.000 | 0.000 | 0.000 | 0.5421 |
23 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
24 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.747 |
25 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
26 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.747 |
27 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
28 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.747 |
29 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
30 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.747 |
31 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
32 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.747 |
33 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
34 | ~FC_Insulation_6 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.747 |
35 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 2.1009573 | 2.1009573 | 2.1009573 | |
3 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
4 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
5 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
6 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
7 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
8 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
9 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
10 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
11 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
12 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
13 | 3 | -0.21589802E-09 | 0.15643069E-09 | -0.21589802E-09 | 0.12999471E-21 |
14 | 2 | 0.50772448E-02 | 0.30006816E-02 | 0.50772448E-02 | -0.13693132E-08 |
15 | 1 | -2.5944910 | 1.4597758 | -2.5944910 | 0.76344767E-02 |
16 | 0 | 7.0433378 | 2.9911476 | 7.0433378 | |
17 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
18 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
19 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
20 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
21 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
22 | 7 | -0.18651654E-16 | -0.16428647E-15 | -0.26578847E-08 | -0.25364002E-17 |
23 | 6 | 0.67402962E-01 | 0.99142722E-07 | 0.38101547E-02 | -0.76639482E-03 |
24 | 5 | -1.8580732 | 0.49502125E-04 | -0.10651409 | 0.21891119E-01 |
25 | 4 | 18.220105 | 0.12801333E-02 | 1.0775450 | -0.22586539 |
26 | 3 | -79.928293 | 0.66708484E-02 | -4.9803755 | 1.0625663 |
27 | 2 | 166.43177 | 0.75131194E-02 | 11.128837 | -2.4125483 |
28 | 1 | -159.97298 | 0.18548900E-02 | -11.587784 | 2.5494418 |
29 | 0 | 57.057412 | 0.52755123E-04 | 4.4818272 | |
30 | 7 | 0.43260499E-16 | 0.34524919E-16 | 0.52793240E-17 | 0.0000000 |
31 | 6 | 0.69434179E-09 | 0.98085174E-11 | 0.18162501E-10 | -0.40870994E-12 |
32 | 5 | -0.12888762E-04 | 0.28373718E-06 | -0.16918523E-06 | 0.92361873E-08 |
33 | 4 | 0.25174112E-01 | 0.33697681E-03 | 0.22646198E-03 | -0.31467795E-04 |
34 | 3 | -3.7600775 | 0.27170599E-01 | -0.48495626E-01 | 0.94171705E-02 |
35 | 2 | 51.553741 | 0.22121684 | 1.2284947 | -0.25833933 |
36 | 1 | -128.86110 | 0.21944682 | -5.1479470 | 1.1228340 |
37 | 0 | 81.526494 | 0.16043334E-01 | 4.4519351 | |
38 | 7 | 0.52793240E-17 | 0.34524919E-16 | 0.43260499E-16 | 0.0000000 |
39 | 6 | 0.18162501E-10 | 0.98085174E-11 | 0.69434179E-09 | -0.40870994E-12 |
40 | 5 | -0.16918523E-06 | 0.28373718E-06 | -0.12888762E-04 | 0.92361873E-08 |
41 | 4 | 0.22646198E-03 | 0.33697681E-03 | 0.25174112E-01 | -0.31467795E-04 |
42 | 3 | -0.48495626E-01 | 0.27170599E-01 | -3.7600775 | 0.94171705E-02 |
43 | 2 | 1.2284947 | 0.22121684 | 51.553741 | -0.25833933 |
44 | 1 | -5.1479470 | 0.21944682 | -128.86110 | 1.1228340 |
45 | 0 | 4.4519351 | 0.16043334E-01 | 81.526494 | |
46 | 3 | -0.63083111E-06 | 0.74112372E-09 | -0.38647046E-05 | 0.15329585E-16 |
47 | 2 | 0.78415922 | 0.99752939E-03 | 1.0633801 | -0.74093433E-06 |
48 | 1 | -22.010056 | 0.66447931E-01 | -6.3131541 | 0.20386814 |
49 | 0 | 21.355302 | 0.61958938E-01 | 5.3791822 | |
50 | 9 | -0.34593716E-15 | 0.37917632E-16 | -0.14273758E-09 | 0.75236294E-18 |
51 | 8 | 0.20892699E-07 | 0.14399041E-12 | 0.36740070E-03 | -0.23755719E-09 |
52 | 7 | -0.11931215E-01 | 0.75570065E-08 | -0.22638899E-01 | 0.13566225E-03 |
53 | 6 | 0.39691749 | 0.26446417E-05 | 0.46490301 | -0.46483591E-02 |
54 | 5 | -5.1082646 | 0.99253035E-04 | -4.3860271 | 0.62163382E-01 |
55 | 4 | 32.638800 | 0.81567581E-03 | 21.224387 | -0.41728928 |
56 | 3 | -110.45159 | 0.17850370E-02 | -55.197058 | 1.5040033 |
57 | 2 | 196.36341 | 0.10077756E-02 | 77.483353 | -2.8885252 |
58 | 1 | -170.88092 | 0.10794924E-03 | -55.141052 | 2.7406170 |
59 | 0 | 57.057407 | 0.61683273E-06 | 15.577585 | |
60 | 9 | -0.27496904E-15 | 0.34099718E-16 | -0.14621944E-09 | 0.14825135E-17 |
61 | 8 | 0.21382694E-07 | 0.13469384E-12 | 0.37260769E-03 | -0.24312860E-09 |
62 | 7 | -0.12086789E-01 | 0.70307525E-08 | -0.22862963E-01 | 0.13743119E-03 |
63 | 6 | 0.40114501 | 0.24550672E-05 | 0.46850838 | -0.46981913E-02 |
64 | 5 | -5.1495237 | 0.91964249E-04 | -4.4137401 | 0.62674972E-01 |
65 | 4 | 32.821321 | 0.75448927E-03 | 21.332760 | -0.41971262 |
66 | 3 | -110.83999 | 0.16486374E-02 | -55.411335 | 1.5096145 |
67 | 2 | 196.74842 | 0.92951629E-03 | 77.679787 | -2.8946391 |
68 | 1 | -171.02317 | 0.99442631E-04 | -55.198003 | 2.7431100 |
69 | 0 | 57.057407 | 0.56743773E-06 | 15.568040 | |
70 | 9 | 0.10083521E-14 | 0.47686560E-16 | -0.12694088E-09 | -0.11529210E-17 |
71 | 8 | 0.18662705E-07 | 0.18406376E-12 | 0.34315612E-03 | -0.21220138E-09 |
72 | 7 | -0.11204959E-01 | 0.99225986E-08 | -0.21592279E-01 | 0.12740445E-03 |
73 | 6 | 0.37717977 | 0.35100568E-05 | 0.44802281 | -0.44157006E-02 |
74 | 5 | -4.9155985 | 0.13295350E-03 | -4.2560675 | 0.59774455E-01 |
75 | 4 | 31.786284 | 0.11017085E-02 | 20.715705 | -0.40597068 |
76 | 3 | -108.63689 | 0.24287072E-02 | -54.191080 | 1.4777872 |
77 | 2 | 194.56382 | 0.13800926E-02 | 76.562002 | -2.8599494 |
78 | 1 | -170.21580 | 0.14871778E-03 | -54.875524 | 2.7289599 |
79 | 0 | 57.057407 | 0.85531379E-06 | 15.623387 | |
80 | 7 | -0.11729247E-08 | -0.12287178E-15 | 0.68000855E-14 | -0.85819789E-16 |
81 | 6 | 0.99010087E-05 | 0.68275672E-08 | 0.31776201E-02 | -0.26656541E-04 |
82 | 5 | -0.71743827E-03 | 0.40498262E-05 | -0.22302824 | 0.19500041E-02 |
83 | 4 | 0.16534150E-01 | 0.18445051E-03 | 4.8179460 | -0.45153479E-01 |
84 | 3 | -0.14527752 | 0.14677644E-02 | -37.955880 | 0.39792938 |
85 | 2 | 0.51595076 | 0.24428280E-02 | 116.35639 | -1.4162330 |
86 | 1 | -0.74475336 | 0.74501918E-03 | -143.83221 | 2.0478056 |
87 | 0 | 0.36311555 | 0.17917760E-04 | 60.838472 | |
88 | 7 | -0.11729247E-08 | -0.12287178E-15 | 0.68000855E-14 | -0.85819789E-16 |
89 | 6 | 0.99010087E-05 | 0.68275672E-08 | 0.31776201E-02 | -0.26656541E-04 |
90 | 5 | -0.71743827E-03 | 0.40498262E-05 | -0.22302824 | 0.19500041E-02 |
91 | 4 | 0.16534150E-01 | 0.18445051E-03 | 4.8179460 | -0.45153479E-01 |
92 | 3 | -0.14527752 | 0.14677644E-02 | -37.955880 | 0.39792938 |
93 | 2 | 0.51595076 | 0.24428280E-02 | 116.35639 | -1.4162330 |
94 | 1 | -0.74475336 | 0.74501918E-03 | -143.83221 | 2.0478056 |
95 | 0 | 0.36311555 | 0.17917760E-04 | 60.838472 | |
96 | 7 | -0.11729247E-08 | -0.12287178E-15 | 0.68000855E-14 | -0.85819789E-16 |
97 | 6 | 0.99010087E-05 | 0.68275672E-08 | 0.31776201E-02 | -0.26656541E-04 |
98 | 5 | -0.71743827E-03 | 0.40498262E-05 | -0.22302824 | 0.19500041E-02 |
99 | 4 | 0.16534150E-01 | 0.18445051E-03 | 4.8179460 | -0.45153479E-01 |
100 | 3 | -0.14527752 | 0.14677644E-02 | -37.955880 | 0.39792938 |
101 | 2 | 0.51595076 | 0.24428280E-02 | 116.35639 | -1.4162330 |
102 | 1 | -0.74475336 | 0.74501918E-03 | -143.83221 | 2.0478056 |
103 | 0 | 0.36311555 | 0.17917760E-04 | 60.838472 | |
104 | 7 | -0.11729247E-08 | -0.12287178E-15 | 0.68000855E-14 | -0.85819789E-16 |
105 | 6 | 0.99010087E-05 | 0.68275672E-08 | 0.31776201E-02 | -0.26656541E-04 |
106 | 5 | -0.71743827E-03 | 0.40498262E-05 | -0.22302824 | 0.19500041E-02 |
107 | 4 | 0.16534150E-01 | 0.18445051E-03 | 4.8179460 | -0.45153479E-01 |
108 | 3 | -0.14527752 | 0.14677644E-02 | -37.955880 | 0.39792938 |
109 | 2 | 0.51595076 | 0.24428280E-02 | 116.35639 | -1.4162330 |
110 | 1 | -0.74475336 | 0.74501918E-03 | -143.83221 | 2.0478056 |
111 | 0 | 0.36311555 | 0.17917760E-04 | 60.838472 | |
112 | 7 | -0.11729247E-08 | -0.12287178E-15 | 0.68000855E-14 | -0.85819789E-16 |
113 | 6 | 0.99010087E-05 | 0.68275672E-08 | 0.31776201E-02 | -0.26656541E-04 |
114 | 5 | -0.71743827E-03 | 0.40498262E-05 | -0.22302824 | 0.19500041E-02 |
115 | 4 | 0.16534150E-01 | 0.18445051E-03 | 4.8179460 | -0.45153479E-01 |
116 | 3 | -0.14527752 | 0.14677644E-02 | -37.955880 | 0.39792938 |
117 | 2 | 0.51595076 | 0.24428280E-02 | 116.35639 | -1.4162330 |
118 | 1 | -0.74475336 | 0.74501918E-03 | -143.83221 | 2.0478056 |
119 | 0 | 0.36311555 | 0.17917760E-04 | 60.838472 | |
120 | 7 | -0.11729247E-08 | -0.12287178E-15 | 0.68000855E-14 | -0.85819789E-16 |
121 | 6 | 0.99010087E-05 | 0.68275672E-08 | 0.31776201E-02 | -0.26656541E-04 |
122 | 5 | -0.71743827E-03 | 0.40498262E-05 | -0.22302824 | 0.19500041E-02 |
123 | 4 | 0.16534150E-01 | 0.18445051E-03 | 4.8179460 | -0.45153479E-01 |
124 | 3 | -0.14527752 | 0.14677644E-02 | -37.955880 | 0.39792938 |
125 | 2 | 0.51595076 | 0.24428280E-02 | 116.35639 | -1.4162330 |
126 | 1 | -0.74475336 | 0.74501918E-03 | -143.83221 | 2.0478056 |
127 | 0 | 0.36311555 | 0.17917760E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | Conductance (Before Adjusted) {W/m2-K} | Convection Coefficient Adjustment Ratio | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | WINDOW_U_0.2925_SHGC_EAST_0.45 | 35 | 1 | VerySmooth | 1.661 | 1.661 | 1.000 | 0.451 | ||
2 | WINDOW_U_0.2925_SHGC_SOUTH_0.45 | 36 | 1 | VerySmooth | 1.661 | 1.661 | 1.000 | 0.451 | ||
3 | WINDOW_U_0.2925_SHGC_WEST_0.45 | 37 | 1 | VerySmooth | 1.661 | 1.661 | 1.000 | 0.451 | ||
4 | WINDOW_U_0.2925_SHGC_NORTH_0.45 | 38 | 1 | VerySmooth | 1.661 | 1.661 | 1.000 | 0.451 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | GLAZING LAYER EAST | SpectralAverage | 4.24435E-002 | 0.36619 | 0.44086 | 0.44086 | 0.45000 | 0.13324 | 0.16828 | 0.00000 | 0.84000 | 0.84000 | 9.92517E-002 | 1.00000 | No | |
2 | GLAZING LAYER SOUTH | SpectralAverage | 4.24435E-002 | 0.36619 | 0.44086 | 0.44086 | 0.45000 | 0.13324 | 0.16828 | 0.00000 | 0.84000 | 0.84000 | 9.92517E-002 | 1.00000 | No | |
3 | GLAZING LAYER WEST | SpectralAverage | 4.24435E-002 | 0.36619 | 0.44086 | 0.44086 | 0.45000 | 0.13324 | 0.16828 | 0.00000 | 0.84000 | 0.84000 | 9.92517E-002 | 1.00000 | No | |
4 | GLAZING LAYER NORTH | SpectralAverage | 4.24435E-002 | 0.36619 | 0.44086 | 0.44086 | 0.45000 | 0.13324 | 0.16828 | 0.00000 | 0.84000 | 0.84000 | 9.92517E-002 | 1.00000 | No |
Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | PolygonClipping | Periodic | 30 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
Enclosure Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Enclosures | |
1 | PERIMETER_BOT_ZN_3 | 5 | 0 |
2 | PERIMETER_BOT_ZN_2 | 3 | 0 |
3 | PERIMETER_BOT_ZN_1 | 5 | 0 |
4 | PERIMETER_BOT_ZN_4 | 3 | 0 |
5 | PERIMETER_MID_ZN_3 | 1 | 0 |
6 | PERIMETER_MID_ZN_2 | 1 | 0 |
7 | PERIMETER_MID_ZN_1 | 1 | 0 |
8 | PERIMETER_MID_ZN_4 | 1 | 0 |
9 | PERIMETER_TOP_ZN_3 | 1 | 0 |
10 | PERIMETER_TOP_ZN_2 | 1 | 0 |
11 | PERIMETER_TOP_ZN_1 | 1 | 0 |
12 | PERIMETER_TOP_ZN_4 | 1 | 0 |
Enclosure Name | Number of Adjacent Enclosures with Windows | Adjacent Enclosure Names - 1st 100 (max) | |
1 | PERIMETER_BOT_ZN_3 | 0 | |
2 | PERIMETER_BOT_ZN_2 | 0 | |
3 | PERIMETER_BOT_ZN_1 | 0 | |
4 | PERIMETER_BOT_ZN_4 | 0 | |
5 | PERIMETER_MID_ZN_3 | 0 | |
6 | PERIMETER_MID_ZN_2 | 0 | |
7 | PERIMETER_MID_ZN_1 | 0 | |
8 | PERIMETER_MID_ZN_4 | 0 | |
9 | PERIMETER_TOP_ZN_3 | 0 | |
10 | PERIMETER_TOP_ZN_2 | 0 | |
11 | PERIMETER_TOP_ZN_1 | 0 | |
12 | PERIMETER_TOP_ZN_4 | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 1.1356 | 87921.3 | 0.496 | 7.5104E-002 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | BASEMENT_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 52.56 | -999.00 | 0 | No | No |
2 | BASEMENT_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 52.56 | -999.00 | 0 | No | No |
3 | BASEMENT_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 52.56 | -999.00 | 0 | No | No |
4 | BASEMENT_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 52.56 | -999.00 | 0 | No | No |
5 | BASEMENT_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 52.56 | -999.00 | 0 | No | No |
6 | PERIMETER_BOT_ZN_2_FLOOR-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 52.56 | -999.00 | 0 | No | No |
7 | PERIMETER_BOT_ZN_1_FLOOR-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 52.56 | -999.00 | 0 | No | No |
8 | CORE_BOT_ZN_5_FLOOR-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 52.56 | -999.00 | 0 | No | No |
9 | PERIMETER_BOT_ZN_3_FLOOR-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 52.56 | -999.00 | 0 | No | No |
10 | BASEMENT_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 52.56 | -999.00 | 0 | No | No |
11 | CORE_BOT_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
12 | CORE_BOT_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
13 | CORE_BOT_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
14 | CORE_BOT_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
15 | DATACENTER_BASEMENT_ZN_6_CEILING-CORE_BOT_ZN_5-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
16 | CORE_BOT_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
17 | CORE_BOT_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
18 | CORE_BOTTOM_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
19 | CORE_MID_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
20 | CORE_MID_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
21 | CORE_MID_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
22 | CORE_MID_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
23 | CORE_MID_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
24 | CORE_MID_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
25 | CORE_MID_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
26 | CORE_TOP_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
27 | CORE_TOP_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
28 | CORE_TOP_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
29 | CORE_TOP_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
30 | CORE_TOP_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
31 | CORE_TOP_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
32 | CORE_TOP_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 48.64 | -999.00 | 0 | No | No |
33 | PERIMETER_BOT_ZN_3_WALL_NORTH | 0 | 869.22 | 250.73 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 3 | No | No |
34 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | 0 | 869.22 | 250.73 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 2 | No | No |
35 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | 0 | 869.22 | 250.73 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 2 | No | No |
36 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | 0 | 869.22 | 250.73 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 2 | No | No |
37 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | 0 | 869.22 | 250.73 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 2 | No | No |
38 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | 0 | 869.22 | 250.73 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 2 | No | No |
39 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | 0 | 869.22 | 250.73 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
40 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | 0 | 869.22 | 250.73 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
41 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR3 | 0 | 869.22 | 250.73 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
42 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR4 | 0 | 869.22 | 250.73 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
43 | PERIMETER_BOT_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
44 | CORE_BOT_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
45 | PERIMETER_BOT_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
46 | DATACENTER_BOT_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
47 | PERIMETER_BOT_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
48 | DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_3-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
49 | PERIMETER_BOT_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
50 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
51 | PERIMETER_BOT_ZN_2_WALL_EAST | 0 | 579.48 | 250.73 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 3 | No | No |
52 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | 0 | 579.48 | 250.73 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 2 | No | No |
53 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | 0 | 579.48 | 250.73 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 2 | No | No |
54 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | 0 | 579.48 | 250.73 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 2 | No | No |
55 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR1 | 0 | 579.48 | 250.73 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
56 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR2 | 0 | 579.48 | 250.73 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
57 | PERIMETER_BOT_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
58 | CORE_BOT_ZN_5_WALL_EAST-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
59 | PERIMETER_BOT_ZN_1_WALL_EAST-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
60 | PERIMETER_BOT_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
61 | PERIMETER_BOT_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
62 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
63 | PERIMETER_BOT_ZN_1_WALL_SOUTH | 0 | 869.22 | 221.21 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 3 | No | No |
64 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | 0 | 869.22 | 221.21 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 2 | No | No |
65 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | 0 | 869.22 | 221.21 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 2 | No | No |
66 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | 0 | 869.22 | 221.21 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 2 | No | No |
67 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | 0 | 869.22 | 221.21 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 2 | No | No |
68 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | 0 | 869.22 | 221.21 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 2 | No | No |
69 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | 0 | 869.22 | 221.21 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
70 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | 0 | 869.22 | 221.21 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
71 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR3 | 0 | 869.22 | 221.21 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
72 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR4 | 0 | 869.22 | 221.21 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
73 | PERIMETER_BOT_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
74 | DATACENTER_BOT_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
75 | PERIMETER_BOT_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
76 | CORE_BOT_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
77 | DATACENTER_BASEMENT_ZN_6-PERIMETER_BOT_ZN_1-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
78 | PERIMETER_BOT_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
79 | PERIMETER_BOT_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
80 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
81 | PERIMETER_BOT_ZN_4_WALL_WEST | 0 | 579.48 | 172.48 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 3 | No | No |
82 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | 0 | 579.48 | 172.48 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 2 | No | No |
83 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | 0 | 579.48 | 172.48 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 2 | No | No |
84 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | 0 | 579.48 | 172.48 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 2 | No | No |
85 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR1 | 0 | 579.48 | 172.48 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
86 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR2 | 0 | 579.48 | 172.48 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
87 | PERIMETER_BOT_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
88 | DATACENTER_BOT_ZN_6_WALL_WEST-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
89 | PERIMETER_BOT_ZN_3_WALL_WEST-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
90 | PERIMETER_BOT_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
91 | PERIMETER_BOT_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
92 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
93 | PERIMETER_MID_ZN_3_WALL_NORTH | 0 | 869.22 | 250.73 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 3 | No | No |
94 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | 0 | 869.22 | 250.73 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 2 | No | No |
95 | PERIMETER_MID_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
96 | CORE_MID_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
97 | PERIMETER_MID_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
98 | DATACENTER_MID_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
99 | PERIMETER_MID_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
100 | PERIMETER_MID_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
101 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
102 | PERIMETER_MID_ZN_2_WALL_EAST | 0 | 579.48 | 250.73 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 3 | No | No |
103 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | 0 | 579.48 | 250.73 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 2 | No | No |
104 | PERIMETER_MID_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
105 | CORE_MID_ZN_5_WALL_EAST-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
106 | PERIMETER_MID_ZN_1_WALL_EAST-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
107 | PERIMETER_MID_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
108 | PERIMETER_MID_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
109 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
110 | PERIMETER_MID_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
111 | PERIMETER_MID_ZN_1_WALL_SOUTH | 0 | 869.22 | 221.21 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 3 | No | No |
112 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | 0 | 869.22 | 221.21 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 2 | No | No |
113 | DATACENTER_MID_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
114 | PERIMETER_MID_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
115 | CORE_MID_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
116 | PERIMETER_MID_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
117 | PERIMETER_MID_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
118 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
119 | PERIMETER_MID_ZN_4_WALL_WEST | 0 | 579.48 | 172.48 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 3 | No | No |
120 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | 0 | 579.48 | 172.48 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 2 | No | No |
121 | PERIMETER_MID_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
122 | DATACENTER_MID_ZN_6_WALL_WEST-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
123 | PERIMETER_MID_ZN_3_WALL_WEST-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
124 | PERIMETER_MID_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
125 | PERIMETER_MID_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
126 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
127 | PERIMETER_TOP_ZN_3_WALL_NORTH | 0 | 869.22 | 250.73 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 3 | No | No |
128 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | 0 | 869.22 | 250.73 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 2 | No | No |
129 | PERIMETER_TOP_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
130 | CORE_TOP_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
131 | PERIMETER_TOP_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
132 | DATACENTER_TOP_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
133 | PERIMETER_TOP_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
134 | PERIMETER_TOP_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
135 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
136 | PERIMETER_TOP_ZN_2_WALL_EAST | 0 | 579.48 | 250.73 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 3 | No | No |
137 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | 0 | 579.48 | 250.73 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 2 | No | No |
138 | PERIMETER_TOP_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
139 | CORE_TOP_ZN_5_WALL_EAST-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
140 | INT-PER3S-NE-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
141 | PERIMETER_TOP_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
142 | PERIMETER_TOP_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
143 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
144 | PERIMETER_TOP_ZN_1_WALL_SOUTH | 0 | 869.22 | 221.21 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 3 | No | No |
145 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | 0 | 869.22 | 221.21 | 37.50 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 2 | No | No |
146 | INT-PER3S-NE | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
147 | DATACENTER_TOP_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
148 | PERIMETER_TOP_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
149 | CORE_TOP_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
150 | PERIMETER_TOP_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
151 | PERIMETER_TOP_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
152 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 73.11 | 8.07 | 0.43 | 0 | No | No |
153 | PERIMETER_TOP_ZN_4_WALL_WEST | 0 | 579.48 | 172.48 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 3 | No | No |
154 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | 0 | 579.48 | 172.48 | 37.50 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 2 | No | No |
155 | PERIMETER_TOP_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
156 | DATACENTER_TOP_ZN_6_WALL_WEST-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
157 | PERIMETER_TOP_ZN_3_WALL_WEST-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
158 | PERIMETER_TOP_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
159 | PERIMETER_TOP_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
160 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 48.74 | 7.58 | 0.43 | 0 | No | No |
161 | GROUNDFLOOR_PLENUM_WALL_NORTH | 0 | 869.22 | 250.73 | 37.50 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
162 | GROUNDFLOOR_PLENUM_WEST | 0 | 579.48 | 172.48 | 37.50 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
163 | GROUNDFLOOR_PLENUM_WALL_SOUTH | 0 | 869.22 | 221.21 | 37.50 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
164 | GROUNDFLOOR_PLENUM_WALL_EAST | 0 | 579.48 | 250.73 | 37.50 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
165 | iz-CORE_BOT_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
166 | iz-PERIMETER_BOT_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
167 | iz-PERIMETER_BOT_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
168 | iz-PERIMETER_BOT_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
169 | iz-PERIMETER_BOT_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
170 | iz-DATACENTER_BOT_ZN_6_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
171 | GROUNDFLOOR_PLENUM_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
172 | MIDFLOOR_PLENUM_WALL_NORTH | 0 | 869.22 | 250.73 | 37.50 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
173 | MIDFLOOR_PLENUM_WALL_WEST | 0 | 579.48 | 172.48 | 37.50 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
174 | MIDFLOOR_PLENUM_WALL_SOUTH | 0 | 869.22 | 221.21 | 37.50 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
175 | MIDFLOOR_PLENUM_WALL_EAST | 0 | 579.48 | 250.73 | 37.50 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
176 | iz-CORE_MID_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
177 | iz-PERIMETER_MID_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
178 | iz-PERIMETER_MID_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
179 | iz-PERIMETER_MID_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
180 | iz-PERIMETER_MID_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
181 | iz-DATACENTER_MID_ZN_6_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
182 | MIDFLOOR_PLENUM_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
183 | TOPFLOOR_PLENUM_WALL_NORTH | 0 | 869.22 | 221.21 | 37.50 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
184 | TOPFLOOR_PLENUM_WALL_EAST | 0 | 579.48 | 250.73 | 37.50 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
185 | TOPFLOOR_PLENUM_WALL_WEST | 0 | 579.48 | 172.48 | 37.50 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
186 | TOPFLOOR_PLENUM_WALL_SOUTH | 0 | 869.22 | 250.73 | 37.50 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
187 | iz-CORE_TOP_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
188 | iz-PERIMETER_TOP_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
189 | iz-PERIMETER_TOP_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
190 | iz-PERIMETER_TOP_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
191 | iz-PERIMETER_TOP_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
192 | iz-DATACENTER_TOP_ZN_6_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
193 | BUILDING_ROOF | 0 | 3563.11 | 268.06 | 0.00 | 0 | 1.22 | 243.69 | 58.49 | 0.00 | 0 | No | No |
194 | DATACENTER_BOT_ZN_6_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
195 | DATACENTER_BOT_ZN_6_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
196 | DATACENTER_BOT_ZN_6_WALL_EAST-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
197 | DATACENTER_BOT_ZN_6_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
198 | DATACENTER_BOT_ZN_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
199 | DATACENTER_BOT_ZN_6_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
200 | DATACENTER_MID_ZN_6_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
201 | DATACENTER_MID_ZN_6_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
202 | DATACENTER_MID_ZN_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
203 | DATACENTER_MID_ZN_6_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
204 | DATACENTER_MID_ZN_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
205 | DATACENTER_MID_ZN_6_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
206 | DATACENTER_TOP_ZN_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
207 | DATACENTER_TOP_ZN_6_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
208 | DATACENTER_TOP_ZN_6_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
209 | DATACENTER_TOP_ZN_6_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
210 | DATACENTER_TOP_ZN_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
211 | DATACENTER_TOP_ZN_6_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 1.79 | -999.00 | 0 | No | No |
212 | DATACENTER_BASEMENT_ZN_6_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 24.18 | -999.00 | 0 | No | No |
213 | DATACENTER_BASEMENT_ZN_6_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 24.18 | -999.00 | 0 | No | No |
214 | DATACENTER_BASEMENT_ZN_6_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 24.18 | -999.00 | 0 | No | No |
215 | DATACENTER_BASEMENT_ZN_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 24.18 | -999.00 | 0 | No | No |
216 | DATACENTER_BASEMENT_ZN_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 24.18 | -999.00 | 0 | No | No |
217 | DATACENTER_BOT_ZN_6_FLOOR-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 24.18 | -999.00 | 0 | No | No |
218 | DATACENTER_BASEMENT_ZN_6_CEILING-CORE_BOT_ZN_5 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 24.18 | -999.00 | 0 | No | No |
219 | PERIMETER_BOT_ZN_4_FLOOR-PPAUTOCREATEOTHER | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 24.18 | -999.00 | 0 | No | No |
220 | DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 24.18 | -999.00 | 0 | No | No |
221 | DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 24.18 | -999.00 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | PERIMETER_BOT_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_3 | 313.41 | 16.9 | 0.114 | 3.646E-004 | 5.482E-004 | 0.478 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | PERIMETER_BOT_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_2 | 201.98 | 10.9 | 7.617E-002 | 3.771E-004 | 5.534E-004 | 0.495 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | PERIMETER_BOT_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_1 | 313.42 | 16.9 | 0.114 | 3.646E-004 | 5.482E-004 | 0.478 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | PERIMETER_BOT_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_4 | 201.98 | 10.9 | 7.617E-002 | 3.771E-004 | 5.534E-004 | 0.495 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | PERIMETER_MID_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_3 | 313.41 | 16.9 | 0.114 | 3.646E-004 | 5.696E-004 | 0.478 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | PERIMETER_MID_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_2 | 201.98 | 10.9 | 7.617E-002 | 3.771E-004 | 5.696E-004 | 0.495 | 0.000 | 0.000 | 0.224 | 0.000 |
7 | PERIMETER_MID_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_1 | 313.42 | 16.9 | 0.114 | 3.646E-004 | 5.696E-004 | 0.478 | 0.000 | 0.000 | 0.224 | 0.000 |
8 | PERIMETER_MID_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_4 | 201.98 | 10.9 | 7.617E-002 | 3.771E-004 | 5.696E-004 | 0.495 | 0.000 | 0.000 | 0.224 | 0.000 |
9 | PERIMETER_TOP_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_3 | 313.41 | 16.9 | 0.114 | 3.646E-004 | 5.696E-004 | 0.478 | 0.000 | 0.000 | 0.224 | 0.000 |
10 | PERIMETER_TOP_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_2 | 201.98 | 10.9 | 7.617E-002 | 3.771E-004 | 5.696E-004 | 0.495 | 0.000 | 0.000 | 0.224 | 0.000 |
11 | PERIMETER_TOP_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_1 | 313.42 | 16.9 | 0.114 | 3.646E-004 | 5.696E-004 | 0.478 | 0.000 | 0.000 | 0.224 | 0.000 |
12 | PERIMETER_TOP_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_4 | 201.98 | 10.9 | 7.617E-002 | 3.771E-004 | 5.696E-004 | 0.495 | 0.000 | 0.000 | 0.224 | 0.000 |
13 | GROUNDFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | GROUNDFLOOR_PLENUM | 3563.11 | 0.0 | 0.169 | 4.749E-005 | 5.696E-004 | 0.140 | 0.000 | 0.000 | 0.224 | 0.000 |
14 | MIDFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | MIDFLOOR_PLENUM | 3563.11 | 0.0 | 0.169 | 4.749E-005 | 5.696E-004 | 0.140 | 0.000 | 0.000 | 0.224 | 0.000 |
15 | TOPFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | TOPFLOOR_PLENUM | 3563.11 | 0.0 | 0.169 | 4.749E-005 | 4.384E-005 | 0.140 | 0.000 | 0.000 | 0.224 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | BASEMENT | Mixing/Well-Stirred |
2 | CORE_BOTTOM | Mixing/Well-Stirred |
3 | CORE_MID | Mixing/Well-Stirred |
4 | CORE_TOP | Mixing/Well-Stirred |
5 | PERIMETER_BOT_ZN_3 | Mixing/Well-Stirred |
6 | PERIMETER_BOT_ZN_2 | Mixing/Well-Stirred |
7 | PERIMETER_BOT_ZN_1 | Mixing/Well-Stirred |
8 | PERIMETER_BOT_ZN_4 | Mixing/Well-Stirred |
9 | PERIMETER_MID_ZN_3 | Mixing/Well-Stirred |
10 | PERIMETER_MID_ZN_2 | Mixing/Well-Stirred |
11 | PERIMETER_MID_ZN_1 | Mixing/Well-Stirred |
12 | PERIMETER_MID_ZN_4 | Mixing/Well-Stirred |
13 | PERIMETER_TOP_ZN_3 | Mixing/Well-Stirred |
14 | PERIMETER_TOP_ZN_2 | Mixing/Well-Stirred |
15 | PERIMETER_TOP_ZN_1 | Mixing/Well-Stirred |
16 | PERIMETER_TOP_ZN_4 | Mixing/Well-Stirred |
17 | GROUNDFLOOR_PLENUM | Mixing/Well-Stirred |
18 | MIDFLOOR_PLENUM | Mixing/Well-Stirred |
19 | TOPFLOOR_PLENUM | Mixing/Well-Stirred |
20 | DATACENTER_BOT_ZN_6 | Mixing/Well-Stirred |
21 | DATACENTER_MID_ZN_6 | Mixing/Well-Stirred |
22 | DATACENTER_TOP_ZN_6 | Mixing/Well-Stirred |
23 | DATACENTER_BASEMENT_ZN_6 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sky Type | MonthAndDay | Daylighting Control Name | Enclosure Name | Window Name | Reference Point | Daylight Factor | |
1 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 6.2722E-003 |
2 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 6.2746E-003 |
3 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 7.0390E-003 |
4 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 7.0410E-003 |
5 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 3.9944E-003 |
6 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 3.9960E-003 |
7 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 2.2272E-003 |
8 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 2.2280E-003 |
9 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 6.3261E-003 |
10 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 6.4824E-003 |
11 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 7.0849E-003 |
12 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 7.2224E-003 |
13 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 4.0332E-003 |
14 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 4.1454E-003 |
15 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 2.2498E-003 |
16 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 2.3065E-003 |
17 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 0.1507 |
18 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 9.3422E-002 |
19 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 0.1730 |
20 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 0.1091 |
21 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 0.1076 |
22 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 4.6632E-002 |
23 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 4.6760E-002 |
24 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.6376E-002 |
25 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 6.3346E-003 |
26 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 6.5269E-003 |
27 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 7.0942E-003 |
28 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 7.2718E-003 |
29 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 4.0401E-003 |
30 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 4.1720E-003 |
31 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 2.2504E-003 |
32 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 2.3082E-003 |
33 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 6.2720E-003 |
34 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 6.2747E-003 |
35 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 7.0388E-003 |
36 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 7.0411E-003 |
37 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 3.9943E-003 |
38 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 3.9961E-003 |
39 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 2.2271E-003 |
40 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 2.2279E-003 |
41 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 5.4409E-003 |
42 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 5.9034E-003 |
43 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 5.3123E-003 |
44 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 5.8537E-003 |
45 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 4.7018E-003 |
46 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 4.8513E-003 |
47 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 3.8114E-003 |
48 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 3.8505E-003 |
49 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 6.3748E-002 |
50 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 3.2768E-002 |
51 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 6.1932E-002 |
52 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 3.0857E-002 |
53 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 6.3763E-002 |
54 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 2.7172E-002 |
55 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 4.8092E-002 |
56 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 1.7944E-002 |
57 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 5.2787E-003 |
58 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 5.3956E-003 |
59 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 5.0971E-003 |
60 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 5.1830E-003 |
61 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 4.6540E-003 |
62 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 4.6881E-003 |
63 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 3.8116E-003 |
64 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 3.8512E-003 |
65 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.4604E-003 |
66 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.4628E-003 |
67 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.0820E-003 |
68 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.0839E-003 |
69 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.8169E-003 |
70 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.8183E-003 |
71 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.2272E-003 |
72 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.2280E-003 |
73 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.5135E-003 |
74 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.6478E-003 |
75 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.1263E-003 |
76 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.2350E-003 |
77 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.8535E-003 |
78 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.9342E-003 |
79 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.2504E-003 |
80 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.3083E-003 |
81 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.1042E-002 |
82 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.3855E-002 |
83 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 3.1805E-002 |
84 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.8151E-002 |
85 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 3.1679E-002 |
86 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.2497E-002 |
87 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.6760E-002 |
88 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.6371E-002 |
89 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.5113E-003 |
90 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.6474E-003 |
91 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.1232E-003 |
92 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.2301E-003 |
93 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.8480E-003 |
94 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.9172E-003 |
95 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.2499E-003 |
96 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.3066E-003 |
97 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.4603E-003 |
98 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.4626E-003 |
99 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.0818E-003 |
100 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.0837E-003 |
101 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.8167E-003 |
102 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.8180E-003 |
103 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.2271E-003 |
104 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.2279E-003 |
105 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 4.7195E-003 |
106 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 4.8412E-003 |
107 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 4.3753E-003 |
108 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 4.4637E-003 |
109 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 4.2694E-003 |
110 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 4.3007E-003 |
111 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 3.8116E-003 |
112 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 3.8512E-003 |
113 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 5.3164E-002 |
114 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 2.8224E-002 |
115 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 4.8382E-002 |
116 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 2.5021E-002 |
117 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 5.5874E-002 |
118 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 2.3837E-002 |
119 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 4.8092E-002 |
120 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 1.7944E-002 |
121 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 4.8391E-003 |
122 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 5.1606E-003 |
123 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 4.5347E-003 |
124 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 4.8916E-003 |
125 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 4.3136E-003 |
126 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 4.4467E-003 |
127 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 3.8114E-003 |
128 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 3.8505E-003 |
129 | Clear Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 0.1446 |
130 | Clear Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 0.1162 |
131 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 0.1613 |
132 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 0.1340 |
133 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 0.1143 |
134 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 6.3408E-002 |
135 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 5.4054E-002 |
136 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 2.6152E-002 |
137 | Clear Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 7.2954E-002 |
138 | Clear Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 4.4946E-002 |
139 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 7.0996E-002 |
140 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 4.2854E-002 |
141 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 7.2033E-002 |
142 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 3.7549E-002 |
143 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 5.5299E-002 |
144 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 2.6428E-002 |
145 | Clear Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 4.8488E-002 |
146 | Clear Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 3.4227E-002 |
147 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 3.8468E-002 |
148 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 2.7012E-002 |
149 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 3.8299E-002 |
150 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 2.0561E-002 |
151 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 5.4054E-002 |
152 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 2.6147E-002 |
153 | Clear Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 6.1458E-002 |
154 | Clear Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 3.8947E-002 |
155 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 5.6263E-002 |
156 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 3.5131E-002 |
157 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 6.3571E-002 |
158 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 3.3367E-002 |
159 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 5.5299E-002 |
160 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 2.6428E-002 |
161 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 0.1444 |
162 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 0.1163 |
163 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 0.1610 |
164 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 0.1342 |
165 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 0.1143 |
166 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 6.3525E-002 |
167 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 5.4117E-002 |
168 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 2.6202E-002 |
169 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 7.2900E-002 |
170 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 4.4984E-002 |
171 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 7.0955E-002 |
172 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 4.2895E-002 |
173 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 7.2048E-002 |
174 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 3.7613E-002 |
175 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 5.5358E-002 |
176 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 2.6479E-002 |
177 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 4.8422E-002 |
178 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 3.4241E-002 |
179 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 3.8422E-002 |
180 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 2.7024E-002 |
181 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 3.8318E-002 |
182 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 2.0593E-002 |
183 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 5.4117E-002 |
184 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 2.6197E-002 |
185 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 6.1407E-002 |
186 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 3.8976E-002 |
187 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 5.6224E-002 |
188 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 3.5159E-002 |
189 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 6.3586E-002 |
190 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 3.3422E-002 |
191 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 5.5358E-002 |
192 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 2.6479E-002 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | BASEMENT | Cooling | 78640.91167 | 78640.91167 | 5.90962 | 5.90962 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 20.92400 | 1.27099E-002 | 2779.42662 | 149.60210 | 1.20016 | 0.00000 |
2 | BASEMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 1.20016 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 2779.42662 | 149.60210 | 1.20016 | 0.00000 |
3 | CORE_BOTTOM | Cooling | 82341.71682 | 82341.71682 | 6.18717 | 6.18717 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 20.92400 | 1.27099E-002 | 2496.12046 | 134.35320 | 1.07782 | 0.00000 |
4 | CORE_BOTTOM | Heating | 9854.57350 | 9854.57350 | 0.43431 | 1.07782 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 2496.12046 | 134.35320 | 1.07782 | 0.00000 |
5 | CORE_MID | Cooling | 773591.75017 | 773591.75017 | 58.11312 | 58.11312 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 20.92400 | 1.27099E-002 | 2496.12046 | 134.35320 | 10.77825 | 0.00000 |
6 | CORE_MID | Heating | 361151.28961 | 361151.28961 | 15.94976 | 15.94976 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 2496.12046 | 134.35320 | 10.77825 | 0.00000 |
7 | CORE_TOP | Cooling | 76074.10807 | 76074.10807 | 5.71464 | 5.71464 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 20.92400 | 1.27099E-002 | 2496.12046 | 134.35320 | 1.07782 | 0.00000 |
8 | CORE_TOP | Heating | 80597.23031 | 80597.23031 | 3.57896 | 3.57896 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 2496.12046 | 134.35320 | 1.07782 | 0.00000 |
9 | PERIMETER_BOT_ZN_3 | Cooling | 12771.02256 | 12771.02256 | 0.96832 | 0.96832 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 30.10000 | 1.27259E-002 | 313.41284 | 16.86939 | 0.13533 | 0.00000 |
10 | PERIMETER_BOT_ZN_3 | Heating | 13996.62760 | 13996.62760 | 0.62233 | 0.62233 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 313.41284 | 16.86939 | 0.13533 | 0.00000 |
11 | PERIMETER_BOT_ZN_2 | Cooling | 17016.24096 | 17016.24096 | 1.29016 | 1.29016 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 21.70933 | 1.27112E-002 | 201.97515 | 10.87127 | 8.72129E-002 | 0.00000 |
12 | PERIMETER_BOT_ZN_2 | Heating | 9601.00657 | 9601.00657 | 0.42697 | 0.42697 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 201.97515 | 10.87127 | 8.72129E-002 | 0.00000 |
13 | PERIMETER_BOT_ZN_1 | Cooling | 21085.08126 | 21085.08126 | 1.59869 | 1.59869 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | 29.68667 | 1.27251E-002 | 313.41969 | 16.86975 | 0.13533 | 0.00000 |
14 | PERIMETER_BOT_ZN_1 | Heating | 15359.46626 | 15359.46626 | 0.68311 | 0.68311 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 313.41969 | 16.86975 | 0.13533 | 0.00000 |
15 | PERIMETER_BOT_ZN_4 | Cooling | 20599.82862 | 20599.82862 | 1.56188 | 1.56188 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:10:00 | 28.15733 | 1.27224E-002 | 201.97515 | 10.87127 | 8.72129E-002 | 0.00000 |
16 | PERIMETER_BOT_ZN_4 | Heating | 7951.71397 | 7951.71397 | 0.35338 | 0.35338 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 201.97515 | 10.87127 | 8.72129E-002 | 0.00000 |
17 | PERIMETER_MID_ZN_3 | Cooling | 118876.52165 | 118876.52165 | 9.01378 | 9.01378 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | 30.10000 | 1.27259E-002 | 313.41284 | 16.86939 | 1.35332 | 0.00000 |
18 | PERIMETER_MID_ZN_3 | Heating | 200892.76812 | 200892.76812 | 8.94053 | 8.94053 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 313.41284 | 16.86939 | 1.35332 | 0.00000 |
19 | PERIMETER_MID_ZN_2 | Cooling | 178643.54076 | 178643.54076 | 13.54544 | 13.54544 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 09:10:00 | 23.63133 | 1.27146E-002 | 201.97515 | 10.87127 | 0.87213 | 0.00000 |
20 | PERIMETER_MID_ZN_2 | Heating | 133237.72506 | 133237.72506 | 5.92997 | 5.92997 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 201.97515 | 10.87127 | 0.87213 | 0.00000 |
21 | PERIMETER_MID_ZN_1 | Cooling | 213332.81537 | 213332.81537 | 16.17577 | 16.17577 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 29.79000 | 1.27253E-002 | 313.41969 | 16.86975 | 1.35335 | 0.00000 |
22 | PERIMETER_MID_ZN_1 | Heating | 202952.83036 | 202952.83036 | 9.03242 | 9.03242 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 313.41969 | 16.86975 | 1.35335 | 0.00000 |
23 | PERIMETER_MID_ZN_4 | Cooling | 188187.70428 | 188187.70428 | 14.26912 | 14.26912 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:20:00 | 27.95067 | 1.27221E-002 | 201.97515 | 10.87127 | 0.87213 | 0.00000 |
24 | PERIMETER_MID_ZN_4 | Heating | 130279.73208 | 130279.73208 | 5.79807 | 5.79807 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 201.97515 | 10.87127 | 0.87213 | 0.00000 |
25 | PERIMETER_TOP_ZN_3 | Cooling | 13210.12047 | 13210.12047 | 1.00167 | 1.00167 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 30.10000 | 1.27259E-002 | 313.41284 | 16.86939 | 0.13533 | 0.00000 |
26 | PERIMETER_TOP_ZN_3 | Heating | 26610.43549 | 26610.43549 | 1.18487 | 1.18487 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 313.41284 | 16.86939 | 0.13533 | 0.00000 |
27 | PERIMETER_TOP_ZN_2 | Cooling | 17850.27152 | 17850.27152 | 1.35350 | 1.35350 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 09:20:00 | 23.98267 | 1.27152E-002 | 201.97515 | 10.87127 | 8.72129E-002 | 0.00000 |
28 | PERIMETER_TOP_ZN_2 | Heating | 17557.50041 | 17557.50041 | 0.78180 | 0.78180 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 201.97515 | 10.87127 | 8.72129E-002 | 0.00000 |
29 | PERIMETER_TOP_ZN_1 | Cooling | 22603.50750 | 22603.50750 | 1.71392 | 1.71392 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 29.99667 | 1.27257E-002 | 313.41969 | 16.86975 | 0.13533 | 0.00000 |
30 | PERIMETER_TOP_ZN_1 | Heating | 26877.38634 | 26877.38634 | 1.19678 | 1.19678 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 313.41969 | 16.86975 | 0.13533 | 0.00000 |
31 | PERIMETER_TOP_ZN_4 | Cooling | 19743.83405 | 19743.83405 | 1.49708 | 1.49708 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:20:00 | 27.95067 | 1.27221E-002 | 201.97515 | 10.87127 | 8.72129E-002 | 0.00000 |
32 | PERIMETER_TOP_ZN_4 | Heating | 17491.54793 | 17491.54793 | 0.77887 | 0.77887 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 201.97515 | 10.87127 | 8.72129E-002 | 0.00000 |
33 | DATACENTER_BOT_ZN_6 | Cooling | 8769.73417 | 8769.73417 | 0.52444 | 0.52444 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:20:00 | 24.80933 | 1.27166E-002 | 36.20274 | 1.94861 | 1.56323E-002 | 0.00000 |
34 | DATACENTER_BOT_ZN_6 | Heating | 0.00000 | 0.00000 | 0.00000 | 1.56323E-002 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:30:00 | -32.70000 | 1.83376E-004 | 36.20274 | 1.94861 | 1.56323E-002 | 0.00000 |
35 | DATACENTER_MID_ZN_6 | Cooling | 84067.61792 | 84067.61792 | 5.02734 | 5.02734 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:20:00 | 24.80933 | 1.27166E-002 | 36.20274 | 1.94861 | 0.15632 | 0.00000 |
36 | DATACENTER_MID_ZN_6 | Heating | 0.00000 | 0.00000 | 0.00000 | 0.15632 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:40:00 | -32.70000 | 1.83376E-004 | 36.20274 | 1.94861 | 0.15632 | 0.00000 |
37 | DATACENTER_TOP_ZN_6 | Cooling | 8526.08797 | 8526.08797 | 0.50987 | 0.50987 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:10:00 | 25.03667 | 1.27170E-002 | 36.20274 | 1.94861 | 1.56323E-002 | 0.00000 |
38 | DATACENTER_TOP_ZN_6 | Heating | 0.00000 | 0.00000 | 0.00000 | 1.56323E-002 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:30:00 | -32.70000 | 1.83376E-004 | 36.20274 | 1.94861 | 1.56323E-002 | 0.00000 |
39 | DATACENTER_BASEMENT_ZN_6 | Cooling | 372606.73243 | 372606.73243 | 22.28196 | 22.28196 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 07:00:00 | 18.81600 | 1.27063E-002 | 783.67941 | 42.18139 | 0.33839 | 0.00000 |
40 | DATACENTER_BASEMENT_ZN_6 | Heating | 0.00000 | 0.00000 | 0.00000 | 0.33839 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 10:20:00 | -32.70000 | 1.83376E-004 | 783.67941 | 42.18139 | 0.33839 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | VAV_BOT WITH REHEAT | Cooling | Sensible | 145124.32 | 10.11005 | 10.11005 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 00:00:00 |
2 | VAV_BOT WITH REHEAT | Heating | Sensible | 133857.99 | 3.16362 | 3.16362 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 06:50:00 |
3 | VAV_MID WITH REHEAT | Cooling | Sensible | 1340165.60 | 93.87859 | 93.87859 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 00:00:00 |
4 | VAV_MID WITH REHEAT | Heating | Sensible | 1338119.60 | 45.65074 | 45.65074 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 22:20:00 |
5 | VAV_TOP WITH REHEAT | Cooling | Sensible | 148221.35 | 10.04357 | 10.04357 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 00:00:00 |
6 | VAV_TOP WITH REHEAT | Heating | Sensible | 133869.76 | 7.52128 | 7.52128 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 03:40:00 |
7 | CAV_BAS | Cooling | Sensible | 75746.53 | 5.90962 | 5.90962 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
8 | CAV_BAS | Heating | Sensible | 101170.70 | 1.20016 | 1.20016 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
9 | AIRLOOP DATACENTER BASEMENT | Cooling | Sensible | 367621.70 | 22.28215 | 22.28215 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
10 | AIRLOOP DATACENTER BASEMENT | Heating | Sensible | 28525.81 | 0.33839 | 0.33839 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
11 | AIRLOOP DATACENTER BOT | Cooling | Sensible | 8594.44 | 0.52444 | 0.52444 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
12 | AIRLOOP DATACENTER BOT | Heating | Sensible | 1317.77 | 1.56323E-002 | 1.56323E-002 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
13 | AIRLOOP DATACENTER MID | Cooling | Sensible | 82370.86 | 5.02734 | 5.02734 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
14 | AIRLOOP DATACENTER MID | Heating | Sensible | 13177.74 | 0.15632 | 0.15632 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
15 | AIRLOOP DATACENTER TOP | Cooling | Sensible | 8358.69 | 0.50987 | 0.50987 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
16 | AIRLOOP DATACENTER TOP | Heating | Sensible | 1317.77 | 1.56323E-002 | 1.56323E-002 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | BASEMENT DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 5.90962 |
2 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 6.18717 |
3 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.30742 |
4 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.31600 |
5 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 1.95514 |
6 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.81978 |
7 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
8 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.23936E-003 |
9 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.51248E-004 |
10 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.95514 |
11 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
12 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
13 | Coil:Heating:Water | CORE_BOTTOM VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 28719.17538 |
14 | Coil:Heating:Water | CORE_BOTTOM VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.51248E-004 |
15 | Coil:Heating:Water | CORE_BOTTOM VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 610.38410 |
16 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 58.11312 |
17 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.32730 |
18 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.33000 |
19 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 19.17733 |
20 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.87280 |
21 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
22 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.16407E-003 |
23 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 4.77829E-003 |
24 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 19.17733 |
25 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
26 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
27 | Coil:Heating:Water | CORE_MID VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 546187.56791 |
28 | Coil:Heating:Water | CORE_MID VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 4.77829E-003 |
29 | Coil:Heating:Water | CORE_MID VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 13699.22438 |
30 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 5.71464 |
31 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.33284 |
32 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.34200 |
33 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 1.95441 |
34 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.88756 |
35 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
36 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.14470E-003 |
37 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.00720E-003 |
38 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 3.57896 |
39 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
40 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
41 | Coil:Heating:Water | CORE_TOP VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 115129.53687 |
42 | Coil:Heating:Water | CORE_TOP VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.00720E-003 |
43 | Coil:Heating:Water | CORE_TOP VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 3038.05107 |
44 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.96832 |
45 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.24664 |
46 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.30000 |
47 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.29049 |
48 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.65769 |
49 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
50 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.54479E-003 |
51 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.74951E-004 |
52 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.62233 |
53 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
54 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
55 | Coil:Heating:Water | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 19997.96446 |
56 | Coil:Heating:Water | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.74951E-004 |
57 | Coil:Heating:Water | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 527.45038 |
58 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.29016 |
59 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.11929 |
60 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.30000 |
61 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.38705 |
62 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.31811 |
63 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
64 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.19386E-003 |
65 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.20016E-004 |
66 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.42697 |
67 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
68 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
69 | Coil:Heating:Water | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 13718.59151 |
70 | Coil:Heating:Water | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.20016E-004 |
71 | Coil:Heating:Water | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 361.80840 |
72 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.59869 |
73 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.14939 |
74 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.30000 |
75 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.47961 |
76 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.39837 |
77 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
78 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.55039E-003 |
79 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.92006E-004 |
80 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.68311 |
81 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
82 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
83 | Coil:Heating:Water | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 21947.41790 |
84 | Coil:Heating:Water | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.92006E-004 |
85 | Coil:Heating:Water | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 578.82141 |
86 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.56188 |
87 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 9.85380E-002 |
88 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.30000 |
89 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.46857 |
90 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.30000 |
91 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
92 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.86653E-003 |
93 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.09088E-004 |
94 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.46857 |
95 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
96 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
97 | Coil:Heating:Water | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 12469.38013 |
98 | Coil:Heating:Water | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.09088E-004 |
99 | Coil:Heating:Water | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 305.18693 |
100 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 9.01378 |
101 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.26495 |
102 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.30000 |
103 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 2.70413 |
104 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.70653 |
105 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
106 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.43800E-003 |
107 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.51153E-003 |
108 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 8.94053 |
109 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
110 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
111 | Coil:Heating:Water | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 287082.77526 |
112 | Coil:Heating:Water | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.51153E-003 |
113 | Coil:Heating:Water | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 7569.30302 |
114 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 13.54544 |
115 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.11362 |
116 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.30000 |
117 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 4.06363 |
118 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.30299 |
119 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
120 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.35324E-003 |
121 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.66574E-003 |
122 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 5.92997 |
123 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
124 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
125 | Coil:Heating:Water | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 190404.40701 |
126 | Coil:Heating:Water | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.66574E-003 |
127 | Coil:Heating:Water | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 5020.15232 |
128 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 16.17577 |
129 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.14764 |
130 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.30000 |
131 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 4.85273 |
132 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.39372 |
133 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
134 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.58053E-003 |
135 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.53730E-003 |
136 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 9.03242 |
137 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
138 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
139 | Coil:Heating:Water | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 290029.28614 |
140 | Coil:Heating:Water | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.53730E-003 |
141 | Coil:Heating:Water | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 7646.94214 |
142 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 14.26912 |
143 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.10786 |
144 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.30000 |
145 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 4.28073 |
146 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.30000 |
147 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
148 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.53239E-003 |
149 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.62873E-003 |
150 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 5.79807 |
151 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
152 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
153 | Coil:Heating:Water | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 186173.95087 |
154 | Coil:Heating:Water | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.62873E-003 |
155 | Coil:Heating:Water | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 4908.66866 |
156 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.18487 |
157 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.20156 |
158 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.30000 |
159 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.35546 |
160 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.53749 |
161 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
162 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.89027E-003 |
163 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 3.32730E-004 |
164 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.18487 |
165 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
166 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
167 | Coil:Heating:Water | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 38033.07382 |
168 | Coil:Heating:Water | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 3.32730E-004 |
169 | Coil:Heating:Water | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1002.62775 |
170 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.35350 |
171 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.11371 |
172 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.30000 |
173 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.40605 |
174 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.30322 |
175 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
176 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.35066E-003 |
177 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.19536E-004 |
178 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.78180 |
179 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
180 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
181 | Coil:Heating:Water | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 25094.30087 |
182 | Coil:Heating:Water | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.19536E-004 |
183 | Coil:Heating:Water | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 661.52721 |
184 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.71392 |
185 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.13934 |
186 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.30000 |
187 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.51418 |
188 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.37159 |
189 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
190 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.73422E-003 |
191 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 3.36070E-004 |
192 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.19678 |
193 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
194 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
195 | Coil:Heating:Water | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 38414.87583 |
196 | Coil:Heating:Water | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 3.36070E-004 |
197 | Coil:Heating:Water | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1012.68819 |
198 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.49708 |
199 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.10280 |
200 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.30000 |
201 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.44912 |
202 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.30000 |
203 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
204 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.70610E-003 |
205 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.18711E-004 |
206 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.77887 |
207 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
208 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
209 | Coil:Heating:Water | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 25000.02133 |
210 | Coil:Heating:Water | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.18711E-004 |
211 | Coil:Heating:Water | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 659.04141 |
212 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | DATACENTER_BOT_ZN_6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.52444 |
213 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | DATACENTER_MID_ZN_6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 5.02734 |
214 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | DATACENTER_TOP_ZN_6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.50987 |
215 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | DATACENTER_BASEMENT_ZN_6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 22.28196 |
216 | AirLoopHVAC | VAV_BOT WITH REHEAT | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 5.80311 |
217 | AirLoopHVAC | VAV_BOT WITH REHEAT | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 3.58086 |
218 | AirLoopHVAC | VAV_BOT WITH REHEAT | Sum of Air Terminal Maximum Flow Rates [m3/s] | 11.60621 |
219 | AirLoopHVAC | VAV_BOT WITH REHEAT | Adjusted Heating Design Air Flow Rate [m3/s] | 3.58086 |
220 | AirLoopHVAC | VAV_BOT WITH REHEAT | Adjusted Cooling Design Air Flow Rate [m3/s] | 10.11005 |
221 | AirLoopHVAC | VAV_BOT WITH REHEAT | Adjusted Main Design Air Flow Rate [m3/s] | 10.11005 |
222 | AirLoopHVAC | VAV_BOT WITH REHEAT | User Heating Air Flow Ratio [] | 0.30000 |
223 | AirLoopHVAC | VAV_BOT WITH REHEAT | Calculated Heating Air Flow Ratio [] | 0.35419 |
224 | AirLoopHVAC | VAV_MID WITH REHEAT | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 55.55861 |
225 | AirLoopHVAC | VAV_MID WITH REHEAT | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 35.07856 |
226 | AirLoopHVAC | VAV_MID WITH REHEAT | Sum of Air Terminal Maximum Flow Rates [m3/s] | 111.11723 |
227 | AirLoopHVAC | VAV_MID WITH REHEAT | Adjusted Heating Design Air Flow Rate [m3/s] | 45.65074 |
228 | AirLoopHVAC | VAV_MID WITH REHEAT | Adjusted Cooling Design Air Flow Rate [m3/s] | 93.87859 |
229 | AirLoopHVAC | VAV_MID WITH REHEAT | Adjusted Main Design Air Flow Rate [m3/s] | 93.87859 |
230 | AirLoopHVAC | VAV_MID WITH REHEAT | User Heating Air Flow Ratio [] | 0.30000 |
231 | AirLoopHVAC | VAV_MID WITH REHEAT | Calculated Heating Air Flow Ratio [] | 0.48627 |
232 | AirLoopHVAC | VAV_TOP WITH REHEAT | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 5.73201 |
233 | AirLoopHVAC | VAV_TOP WITH REHEAT | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 3.67922 |
234 | AirLoopHVAC | VAV_TOP WITH REHEAT | Sum of Air Terminal Maximum Flow Rates [m3/s] | 11.46401 |
235 | AirLoopHVAC | VAV_TOP WITH REHEAT | Adjusted Heating Design Air Flow Rate [m3/s] | 7.52128 |
236 | AirLoopHVAC | VAV_TOP WITH REHEAT | Adjusted Cooling Design Air Flow Rate [m3/s] | 10.04357 |
237 | AirLoopHVAC | VAV_TOP WITH REHEAT | Adjusted Main Design Air Flow Rate [m3/s] | 10.04357 |
238 | AirLoopHVAC | VAV_TOP WITH REHEAT | User Heating Air Flow Ratio [] | 0.30000 |
239 | AirLoopHVAC | VAV_TOP WITH REHEAT | Calculated Heating Air Flow Ratio [] | 0.74887 |
240 | AirLoopHVAC | CAV_BAS | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 5.90962 |
241 | AirLoopHVAC | CAV_BAS | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 5.90962 |
242 | AirLoopHVAC | CAV_BAS | Sum of Air Terminal Maximum Flow Rates [m3/s] | 5.90962 |
243 | AirLoopHVAC | CAV_BAS | Adjusted Heating Design Air Flow Rate [m3/s] | 5.90962 |
244 | AirLoopHVAC | CAV_BAS | Adjusted Cooling Design Air Flow Rate [m3/s] | 5.90962 |
245 | AirLoopHVAC | CAV_BAS | Adjusted Main Design Air Flow Rate [m3/s] | 5.90962 |
246 | AirLoopHVAC | CAV_BAS | User Heating Air Flow Ratio [] | 1.00000 |
247 | AirLoopHVAC | CAV_BAS | Calculated Heating Air Flow Ratio [] | 1.00000 |
248 | AirLoopHVAC | AIRLOOP DATACENTER BASEMENT | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 22.28196 |
249 | AirLoopHVAC | AIRLOOP DATACENTER BASEMENT | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 22.28196 |
250 | AirLoopHVAC | AIRLOOP DATACENTER BASEMENT | Sum of Air Terminal Maximum Flow Rates [m3/s] | 22.28196 |
251 | AirLoopHVAC | AIRLOOP DATACENTER BASEMENT | Adjusted Heating Design Air Flow Rate [m3/s] | 22.28196 |
252 | AirLoopHVAC | AIRLOOP DATACENTER BASEMENT | Adjusted Cooling Design Air Flow Rate [m3/s] | 22.28215 |
253 | AirLoopHVAC | AIRLOOP DATACENTER BASEMENT | Adjusted Main Design Air Flow Rate [m3/s] | 22.28215 |
254 | AirLoopHVAC | AIRLOOP DATACENTER BASEMENT | User Heating Air Flow Ratio [] | 1.00000 |
255 | AirLoopHVAC | AIRLOOP DATACENTER BASEMENT | Calculated Heating Air Flow Ratio [] | 0.99999 |
256 | AirLoopHVAC | AIRLOOP DATACENTER BOT | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.52444 |
257 | AirLoopHVAC | AIRLOOP DATACENTER BOT | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.52444 |
258 | AirLoopHVAC | AIRLOOP DATACENTER BOT | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.52444 |
259 | AirLoopHVAC | AIRLOOP DATACENTER BOT | Adjusted Heating Design Air Flow Rate [m3/s] | 0.52444 |
260 | AirLoopHVAC | AIRLOOP DATACENTER BOT | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.52444 |
261 | AirLoopHVAC | AIRLOOP DATACENTER BOT | Adjusted Main Design Air Flow Rate [m3/s] | 0.52444 |
262 | AirLoopHVAC | AIRLOOP DATACENTER BOT | User Heating Air Flow Ratio [] | 1.00000 |
263 | AirLoopHVAC | AIRLOOP DATACENTER BOT | Calculated Heating Air Flow Ratio [] | 1.00000 |
264 | AirLoopHVAC | AIRLOOP DATACENTER MID | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 5.02734 |
265 | AirLoopHVAC | AIRLOOP DATACENTER MID | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 5.02734 |
266 | AirLoopHVAC | AIRLOOP DATACENTER MID | Sum of Air Terminal Maximum Flow Rates [m3/s] | 5.02734 |
267 | AirLoopHVAC | AIRLOOP DATACENTER MID | Adjusted Heating Design Air Flow Rate [m3/s] | 5.02734 |
268 | AirLoopHVAC | AIRLOOP DATACENTER MID | Adjusted Cooling Design Air Flow Rate [m3/s] | 5.02734 |
269 | AirLoopHVAC | AIRLOOP DATACENTER MID | Adjusted Main Design Air Flow Rate [m3/s] | 5.02734 |
270 | AirLoopHVAC | AIRLOOP DATACENTER MID | User Heating Air Flow Ratio [] | 1.00000 |
271 | AirLoopHVAC | AIRLOOP DATACENTER MID | Calculated Heating Air Flow Ratio [] | 1.00000 |
272 | AirLoopHVAC | AIRLOOP DATACENTER TOP | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.50987 |
273 | AirLoopHVAC | AIRLOOP DATACENTER TOP | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.50987 |
274 | AirLoopHVAC | AIRLOOP DATACENTER TOP | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.50987 |
275 | AirLoopHVAC | AIRLOOP DATACENTER TOP | Adjusted Heating Design Air Flow Rate [m3/s] | 0.50987 |
276 | AirLoopHVAC | AIRLOOP DATACENTER TOP | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.50987 |
277 | AirLoopHVAC | AIRLOOP DATACENTER TOP | Adjusted Main Design Air Flow Rate [m3/s] | 0.50987 |
278 | AirLoopHVAC | AIRLOOP DATACENTER TOP | User Heating Air Flow Ratio [] | 1.00000 |
279 | AirLoopHVAC | AIRLOOP DATACENTER TOP | Calculated Heating Air Flow Ratio [] | 1.00000 |
280 | AirLoopHVAC | VAV_BOT WITH REHEAT | Design Supply Air Flow Rate [m3/s] | 10.11005 |
281 | AirLoopHVAC | VAV_MID WITH REHEAT | Design Supply Air Flow Rate [m3/s] | 93.87859 |
282 | AirLoopHVAC | VAV_TOP WITH REHEAT | Design Supply Air Flow Rate [m3/s] | 10.04357 |
283 | AirLoopHVAC | CAV_BAS | Design Supply Air Flow Rate [m3/s] | 5.90962 |
284 | AirLoopHVAC | AIRLOOP DATACENTER BASEMENT | Design Supply Air Flow Rate [m3/s] | 22.28215 |
285 | AirLoopHVAC | AIRLOOP DATACENTER BOT | Design Supply Air Flow Rate [m3/s] | 0.52444 |
286 | AirLoopHVAC | AIRLOOP DATACENTER MID | Design Supply Air Flow Rate [m3/s] | 5.02734 |
287 | AirLoopHVAC | AIRLOOP DATACENTER TOP | Design Supply Air Flow Rate [m3/s] | 0.50987 |
288 | Controller:OutdoorAir | VAV_BOT WITH REHEAT_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 10.11005 |
289 | Controller:OutdoorAir | VAV_BOT WITH REHEAT_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.53819 |
290 | HeatExchanger:AirToAir:SensibleAndLatent | VAV_BOT WITH REHEAT OA HEAT RECOVERY | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.53819 |
291 | Coil:Cooling:Water | VAV_BOT WITH REHEAT COOLING COIL | Design Size Design Inlet Air Temperature [C] | 25.57995 |
292 | Coil:Cooling:Water | VAV_BOT WITH REHEAT COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.67000 |
293 | Coil:Cooling:Water | VAV_BOT WITH REHEAT COOLING COIL | Design Size Design Outlet Air Temperature [C] | 10.87602 |
294 | Coil:Cooling:Water | VAV_BOT WITH REHEAT COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 9.86775E-003 |
295 | Coil:Cooling:Water | VAV_BOT WITH REHEAT COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
296 | Coil:Cooling:Water | VAV_BOT WITH REHEAT COOLING COIL | Design Size Design Coil Load [W] | 215745.20840 |
297 | Coil:Cooling:Water | VAV_BOT WITH REHEAT COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 9.17830E-003 |
298 | Coil:Cooling:Water | VAV_BOT WITH REHEAT COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 10.11005 |
299 | Coil:Heating:Water | VAV_BOT WITH REHEAT HEATING COIL | Design Size Rated Capacity [W] | 129814.53317 |
300 | Coil:Heating:Water | VAV_BOT WITH REHEAT HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.13567E-003 |
301 | Coil:Heating:Water | VAV_BOT WITH REHEAT HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 1867.90015 |
302 | Fan:VariableVolume | VAV_BOT WITH REHEAT FAN | Design Size Maximum Flow Rate [m3/s] | 10.11005 |
303 | Controller:WaterCoil | VAV_BOT WITH REHEAT_COOLC_CONTROLLER | Maximum Actuated Flow [m3/s] | 9.17830E-003 |
304 | Controller:WaterCoil | VAV_BOT WITH REHEAT_COOLC_CONTROLLER | Controller Convergence Tolerance | 5.18822E-005 |
305 | Controller:WaterCoil | VAV_BOT WITH REHEAT_HEATC_CONTROLLER | Maximum Actuated Flow [m3/s] | 1.13567E-003 |
306 | Controller:OutdoorAir | VAV_MID WITH REHEAT_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 93.87859 |
307 | Controller:OutdoorAir | VAV_MID WITH REHEAT_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 25.38195 |
308 | HeatExchanger:AirToAir:SensibleAndLatent | VAV_MID WITH REHEAT OA HEAT RECOVERY | Design Size Nominal Supply Air Flow Rate [m3/s] | 25.38195 |
309 | Coil:Cooling:Water | VAV_MID WITH REHEAT COOLING COIL | Design Size Design Inlet Air Temperature [C] | 25.73109 |
310 | Coil:Cooling:Water | VAV_MID WITH REHEAT COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.67000 |
311 | Coil:Cooling:Water | VAV_MID WITH REHEAT COOLING COIL | Design Size Design Outlet Air Temperature [C] | 10.86629 |
312 | Coil:Cooling:Water | VAV_MID WITH REHEAT COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 1.00236E-002 |
313 | Coil:Cooling:Water | VAV_MID WITH REHEAT COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
314 | Coil:Cooling:Water | VAV_MID WITH REHEAT COOLING COIL | Design Size Design Coil Load [W] | 2064211.47267 |
315 | Coil:Cooling:Water | VAV_MID WITH REHEAT COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 8.78163E-002 |
316 | Coil:Cooling:Water | VAV_MID WITH REHEAT COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 93.87859 |
317 | Coil:Heating:Water | VAV_MID WITH REHEAT HEATING COIL | Design Size Rated Capacity [W] | 1312673.62189 |
318 | Coil:Heating:Water | VAV_MID WITH REHEAT HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.14838E-002 |
319 | Coil:Heating:Water | VAV_MID WITH REHEAT HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 18441.22124 |
320 | Fan:VariableVolume | VAV_MID WITH REHEAT FAN | Design Size Maximum Flow Rate [m3/s] | 93.87859 |
321 | Controller:WaterCoil | VAV_MID WITH REHEAT_COOLC_CONTROLLER | Maximum Actuated Flow [m3/s] | 8.78163E-002 |
322 | Controller:WaterCoil | VAV_MID WITH REHEAT_COOLC_CONTROLLER | Controller Convergence Tolerance | 5.42257E-006 |
323 | Controller:WaterCoil | VAV_MID WITH REHEAT_HEATC_CONTROLLER | Maximum Actuated Flow [m3/s] | 1.14838E-002 |
324 | Controller:OutdoorAir | VAV_TOP WITH REHEAT_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 10.04357 |
325 | Controller:OutdoorAir | VAV_TOP WITH REHEAT_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.53819 |
326 | HeatExchanger:AirToAir:SensibleAndLatent | VAV_TOP WITH REHEAT OA HEAT RECOVERY | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.53819 |
327 | Coil:Cooling:Water | VAV_TOP WITH REHEAT COOLING COIL | Design Size Design Inlet Air Temperature [C] | 25.54208 |
328 | Coil:Cooling:Water | VAV_TOP WITH REHEAT COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.67000 |
329 | Coil:Cooling:Water | VAV_TOP WITH REHEAT COOLING COIL | Design Size Design Outlet Air Temperature [C] | 10.87608 |
330 | Coil:Cooling:Water | VAV_TOP WITH REHEAT COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 9.88416E-003 |
331 | Coil:Cooling:Water | VAV_TOP WITH REHEAT COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
332 | Coil:Cooling:Water | VAV_TOP WITH REHEAT COOLING COIL | Design Size Design Coil Load [W] | 214361.48285 |
333 | Coil:Cooling:Water | VAV_TOP WITH REHEAT COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 9.11943E-003 |
334 | Coil:Cooling:Water | VAV_TOP WITH REHEAT COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 10.04357 |
335 | Coil:Heating:Water | VAV_TOP WITH REHEAT HEATING COIL | Design Size Rated Capacity [W] | 131950.32315 |
336 | Coil:Heating:Water | VAV_TOP WITH REHEAT HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.15436E-003 |
337 | Coil:Heating:Water | VAV_TOP WITH REHEAT HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 1886.54411 |
338 | Fan:VariableVolume | VAV_TOP WITH REHEAT FAN | Design Size Maximum Flow Rate [m3/s] | 10.04357 |
339 | Controller:WaterCoil | VAV_TOP WITH REHEAT_COOLC_CONTROLLER | Maximum Actuated Flow [m3/s] | 9.11943E-003 |
340 | Controller:WaterCoil | VAV_TOP WITH REHEAT_COOLC_CONTROLLER | Controller Convergence Tolerance | 5.22171E-005 |
341 | Controller:WaterCoil | VAV_TOP WITH REHEAT_HEATC_CONTROLLER | Maximum Actuated Flow [m3/s] | 1.15436E-003 |
342 | Controller:OutdoorAir | CAV_BAS_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 5.90962 |
343 | Controller:OutdoorAir | CAV_BAS_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 1.20016 |
344 | HeatExchanger:AirToAir:SensibleAndLatent | CAV_BAS OA HEAT RECOVERY | Design Size Nominal Supply Air Flow Rate [m3/s] | 1.20016 |
345 | Coil:Cooling:Water | CAV_BAS COOLING COIL | Design Size Design Inlet Air Temperature [C] | 25.25269 |
346 | Coil:Cooling:Water | CAV_BAS COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.67000 |
347 | Coil:Cooling:Water | CAV_BAS COOLING COIL | Design Size Design Outlet Air Temperature [C] | 11.36377 |
348 | Coil:Cooling:Water | CAV_BAS COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 9.84370E-003 |
349 | Coil:Cooling:Water | CAV_BAS COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
350 | Coil:Cooling:Water | CAV_BAS COOLING COIL | Design Size Design Coil Load [W] | 120013.42952 |
351 | Coil:Cooling:Water | CAV_BAS COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 5.10565E-003 |
352 | Coil:Cooling:Water | CAV_BAS COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 5.90962 |
353 | Coil:Heating:Water | CAV_BAS HEATING COIL | Design Size Rated Capacity [W] | 319601.40062 |
354 | Coil:Heating:Water | CAV_BAS HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.79601E-003 |
355 | Coil:Heating:Water | CAV_BAS HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 6737.17247 |
356 | Fan:ConstantVolume | CAV_BAS FAN | Design Size Maximum Flow Rate [m3/s] | 5.90962 |
357 | Controller:WaterCoil | CAV_BAS_COOLC_CONTROLLER | Maximum Actuated Flow [m3/s] | 5.10565E-003 |
358 | Controller:WaterCoil | CAV_BAS_COOLC_CONTROLLER | Controller Convergence Tolerance | 9.32674E-005 |
359 | Controller:WaterCoil | CAV_BAS_HEATC_CONTROLLER | Maximum Actuated Flow [m3/s] | 2.79601E-003 |
360 | Controller:OutdoorAir | AIRLOOP DATACENTER BASEMENT_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 22.28215 |
361 | Controller:OutdoorAir | AIRLOOP DATACENTER BASEMENT_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.33839 |
362 | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER BASEMENT COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 22.28215 |
363 | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER BASEMENT COOLING COIL | Design Size Rated Total Cooling Capacity [W] | 436569.55630 |
364 | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER BASEMENT COOLING COIL | Design Size Rated Sensible Cooling Capacity [W] | 301670.86123 |
365 | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER BASEMENT COOLING COIL | Design Size Rated Water Flow Rate [m3/s] | 1.06916E-002 |
366 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER BASEMENT DXAC HEAT PUMP | Supply Air Flow Rate [m3/s] | 22.28215 |
367 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER BASEMENT DXAC HEAT PUMP | Supply Air Flow Rate During Heating Operation [m3/s] | 22.28215 |
368 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER BASEMENT DXAC HEAT PUMP | Supply Air Flow Rate During Cooling Operation [m3/s] | 22.28215 |
369 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER BASEMENT DXAC HEAT PUMP | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 22.28215 |
370 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER BASEMENT DXAC HEAT PUMP | Nominal Heating Capacity [W] | 436569.55630 |
371 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER BASEMENT DXAC HEAT PUMP | Nominal Cooling Capacity [W] | 436569.55630 |
372 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER BASEMENT DXAC HEAT PUMP | Supplemental Heating Coil Nominal Capacity [W] | 28525.80837 |
373 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER BASEMENT DXAC HEAT PUMP | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
374 | Fan:OnOff | AIRLOOP DATACENTER BASEMENT SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 22.28215 |
375 | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER BASEMENT HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 22.28215 |
376 | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER BASEMENT HEATING COIL | Design Size Rated Heating Capacity [W] | 436569.55630 |
377 | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER BASEMENT HEATING COIL | Design Size Rated Water Flow Rate [m3/s] | 1.06916E-002 |
378 | Coil:Heating:Electric | AIRLOOP DATACENTER BASEMENT_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 28525.80837 |
379 | Humidifier:Steam:Electric | DATACENTER_BASEMENT_ZN_6 HUMIDIFIER | Design Size Nominal Capacity Volume [m3/s] | 2.05972E-004 |
380 | Humidifier:Steam:Electric | DATACENTER_BASEMENT_ZN_6 HUMIDIFIER | User-Specified Nominal Capacity Volume [m3/s] | 3.72000E-005 |
381 | Humidifier:Steam:Electric | DATACENTER_BASEMENT_ZN_6 HUMIDIFIER | Design Size Rated Power [W] | 96450.69782 |
382 | Humidifier:Steam:Electric | DATACENTER_BASEMENT_ZN_6 HUMIDIFIER | User-Specified Rated Power [W] | 100000.00000 |
383 | Controller:OutdoorAir | AIRLOOP DATACENTER BOT_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.52444 |
384 | Controller:OutdoorAir | AIRLOOP DATACENTER BOT_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 1.56323E-002 |
385 | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER BOT COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.52444 |
386 | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER BOT COOLING COIL | Design Size Rated Total Cooling Capacity [W] | 10097.06298 |
387 | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER BOT COOLING COIL | Design Size Rated Sensible Cooling Capacity [W] | 7032.29759 |
388 | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER BOT COOLING COIL | Design Size Rated Water Flow Rate [m3/s] | 2.47276E-004 |
389 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER BOT DXAC HEAT PUMP | Supply Air Flow Rate [m3/s] | 0.52444 |
390 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER BOT DXAC HEAT PUMP | Supply Air Flow Rate During Heating Operation [m3/s] | 0.52444 |
391 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER BOT DXAC HEAT PUMP | Supply Air Flow Rate During Cooling Operation [m3/s] | 0.52444 |
392 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER BOT DXAC HEAT PUMP | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 0.52444 |
393 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER BOT DXAC HEAT PUMP | Nominal Heating Capacity [W] | 10097.06298 |
394 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER BOT DXAC HEAT PUMP | Nominal Cooling Capacity [W] | 10097.06298 |
395 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER BOT DXAC HEAT PUMP | Supplemental Heating Coil Nominal Capacity [W] | 1317.77417 |
396 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER BOT DXAC HEAT PUMP | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
397 | Fan:OnOff | AIRLOOP DATACENTER BOT SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.52444 |
398 | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER BOT HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.52444 |
399 | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER BOT HEATING COIL | Design Size Rated Heating Capacity [W] | 10097.06298 |
400 | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER BOT HEATING COIL | Design Size Rated Water Flow Rate [m3/s] | 2.47276E-004 |
401 | Coil:Heating:Electric | AIRLOOP DATACENTER BOT_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 1317.77417 |
402 | Controller:OutdoorAir | AIRLOOP DATACENTER MID_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 5.02734 |
403 | Controller:OutdoorAir | AIRLOOP DATACENTER MID_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.15632 |
404 | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER MID COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 5.02734 |
405 | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER MID COOLING COIL | Design Size Rated Total Cooling Capacity [W] | 96893.41327 |
406 | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER MID COOLING COIL | Design Size Rated Sensible Cooling Capacity [W] | 67443.17301 |
407 | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER MID COOLING COIL | Design Size Rated Water Flow Rate [m3/s] | 2.37291E-003 |
408 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER MID DXAC HEAT PUMP | Supply Air Flow Rate [m3/s] | 5.02734 |
409 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER MID DXAC HEAT PUMP | Supply Air Flow Rate During Heating Operation [m3/s] | 5.02734 |
410 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER MID DXAC HEAT PUMP | Supply Air Flow Rate During Cooling Operation [m3/s] | 5.02734 |
411 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER MID DXAC HEAT PUMP | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 5.02734 |
412 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER MID DXAC HEAT PUMP | Nominal Heating Capacity [W] | 96893.41327 |
413 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER MID DXAC HEAT PUMP | Nominal Cooling Capacity [W] | 96893.41327 |
414 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER MID DXAC HEAT PUMP | Supplemental Heating Coil Nominal Capacity [W] | 13177.74171 |
415 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER MID DXAC HEAT PUMP | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
416 | Fan:OnOff | AIRLOOP DATACENTER MID SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 5.02734 |
417 | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER MID HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 5.02734 |
418 | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER MID HEATING COIL | Design Size Rated Heating Capacity [W] | 96893.41327 |
419 | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER MID HEATING COIL | Design Size Rated Water Flow Rate [m3/s] | 2.37291E-003 |
420 | Coil:Heating:Electric | AIRLOOP DATACENTER MID_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 13177.74171 |
421 | Controller:OutdoorAir | AIRLOOP DATACENTER TOP_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.50987 |
422 | Controller:OutdoorAir | AIRLOOP DATACENTER TOP_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 1.56323E-002 |
423 | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER TOP COOLING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.50987 |
424 | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER TOP COOLING COIL | Design Size Rated Total Cooling Capacity [W] | 9826.63564 |
425 | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER TOP COOLING COIL | Design Size Rated Sensible Cooling Capacity [W] | 6840.09677 |
426 | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER TOP COOLING COIL | Design Size Rated Water Flow Rate [m3/s] | 2.40654E-004 |
427 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER TOP DXAC HEAT PUMP | Supply Air Flow Rate [m3/s] | 0.50987 |
428 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER TOP DXAC HEAT PUMP | Supply Air Flow Rate During Heating Operation [m3/s] | 0.50987 |
429 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER TOP DXAC HEAT PUMP | Supply Air Flow Rate During Cooling Operation [m3/s] | 0.50987 |
430 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER TOP DXAC HEAT PUMP | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | 0.50987 |
431 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER TOP DXAC HEAT PUMP | Nominal Heating Capacity [W] | 9826.63564 |
432 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER TOP DXAC HEAT PUMP | Nominal Cooling Capacity [W] | 9826.63564 |
433 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER TOP DXAC HEAT PUMP | Supplemental Heating Coil Nominal Capacity [W] | 1317.77417 |
434 | AirLoopHVAC:UnitaryHeatPump:WaterToAir | AIRLOOP DATACENTER TOP DXAC HEAT PUMP | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
435 | Fan:OnOff | AIRLOOP DATACENTER TOP SUPPLY FAN | Design Size Maximum Flow Rate [m3/s] | 0.50987 |
436 | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER TOP HEATING COIL | Design Size Rated Air Flow Rate [m3/s] | 0.50987 |
437 | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER TOP HEATING COIL | Design Size Rated Heating Capacity [W] | 9826.63564 |
438 | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AIRLOOP DATACENTER TOP HEATING COIL | Design Size Rated Water Flow Rate [m3/s] | 2.40654E-004 |
439 | Coil:Heating:Electric | AIRLOOP DATACENTER TOP_SUPPHEATCOIL | Design Size Nominal Capacity [W] | 1317.77417 |
440 | Pump:VariableSpeed | COOLSYS1 PUMP SECONDARY | Design Flow Rate [m3/s] | 0.11122 |
441 | Pump:VariableSpeed | COOLSYS1 PUMP SECONDARY | Design Power Consumption [W] | 22918.25994 |
442 | PlantLoop | COOLSYS1_DEMAND | Maximum Loop Flow Rate [m3/s] | 0.11122 |
443 | PlantLoop | COOLSYS1_DEMAND | Plant Loop Volume [m3] | 13.34637 |
444 | HeatExchanger:FluidToFluid | BYPASS HEAT EXCHANGER | Loop Supply Side Design Fluid Flow Rate [m3/s] | 0.11122 |
445 | HeatExchanger:FluidToFluid | BYPASS HEAT EXCHANGER | Loop Demand Side Design Fluid Flow Rate [m3/s] | 0.11122 |
446 | HeatExchanger:FluidToFluid | BYPASS HEAT EXCHANGER | Heat Exchanger U-Factor Times Area Value [W/C] | 466844.92740 |
447 | HeatExchanger:FluidToFluid | BYPASS HEAT EXCHANGER | Loop-to-loop Temperature Difference Used to Size Heat Exchanger U-Factor Times Area Value [C] | 5.60000 |
448 | PlantLoop | HEATSYS1 | Maximum Loop Flow Rate [m3/s] | 3.26530E-002 |
449 | PlantLoop | HEATSYS1 | Plant Loop Volume [m3] | 3.91836 |
450 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Flow Rate [m3/s] | 3.26530E-002 |
451 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Power Consumption [W] | 9833.65948 |
452 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Minimum Flow Rate [m3/s] | 0.00000 |
453 | Boiler:HotWater | HEATSYS1 BOILER | Design Size Nominal Capacity [W] | 3732442.20412 |
454 | Boiler:HotWater | HEATSYS1 BOILER | User-Specified Nominal Capacity [W] | 3732442.20000 |
455 | Boiler:HotWater | HEATSYS1 BOILER | Design Size Design Water Flow Rate [m3/s] | 3.26530E-002 |
456 | PlantLoop | COOLSYS1_SUPPLY | Maximum Loop Flow Rate [m3/s] | 0.11122 |
457 | PlantLoop | COOLSYS1_SUPPLY | Plant Loop Volume [m3] | 13.34637 |
458 | Pump:ConstantSpeed | COOLSYS1 PUMP | Design Flow Rate [m3/s] | 0.11122 |
459 | Pump:ConstantSpeed | COOLSYS1 PUMP | Design Power Consumption [W] | 15867.08445 |
460 | Chiller:Electric:ReformulatedEIR | COOLSYS1 CHILLER1 | Design Size Reference Chilled Water Flow Rate [m3/s] | 0.11122 |
461 | Chiller:Electric:ReformulatedEIR | COOLSYS1 CHILLER1 | User-Specified Reference Chilled Water Flow Rate [m3/s] | 5.59100E-002 |
462 | Chiller:Electric:ReformulatedEIR | COOLSYS1 CHILLER1 | Design Size Reference Capacity [W] | 1317449.35642 |
463 | Chiller:Electric:ReformulatedEIR | COOLSYS1 CHILLER1 | User-Specified Reference Capacity [W] | 1323676.83000 |
464 | Chiller:Electric:ReformulatedEIR | COOLSYS1 CHILLER1 | Design Size Reference Condenser Water Flow Rate [m3/s] | 6.55039E-002 |
465 | Chiller:Electric:ReformulatedEIR | COOLSYS1 CHILLER2 | Design Size Reference Chilled Water Flow Rate [m3/s] | 0.11122 |
466 | Chiller:Electric:ReformulatedEIR | COOLSYS1 CHILLER2 | User-Specified Reference Chilled Water Flow Rate [m3/s] | 5.59100E-002 |
467 | Chiller:Electric:ReformulatedEIR | COOLSYS1 CHILLER2 | Design Size Reference Capacity [W] | 1317449.35642 |
468 | Chiller:Electric:ReformulatedEIR | COOLSYS1 CHILLER2 | User-Specified Reference Capacity [W] | 1323676.83000 |
469 | Chiller:Electric:ReformulatedEIR | COOLSYS1 CHILLER2 | Design Size Reference Condenser Water Flow Rate [m3/s] | 6.55039E-002 |
470 | PlantLoop | SINGLE WATER PLANT LOOP | Maximum Loop Flow Rate [m3/s] | 1.35524E-002 |
471 | PlantLoop | SINGLE WATER PLANT LOOP | Plant Loop Volume [m3] | 1.62629 |
472 | Pump:ConstantSpeed | PLANT CIRC PUMP | Design Flow Rate [m3/s] | 1.35524E-002 |
473 | Pump:ConstantSpeed | PLANT CIRC PUMP | Design Power Consumption [W] | 3456.54071 |
474 | FluidCooler:TwoSpeed | CENTRAL TOWER | Design Water Flow Rate [m3/s] | 1.35524E-002 |
475 | FluidCooler:TwoSpeed | CENTRAL TOWER | Air Flow Rate at High Fan Speed [m3/s] | 139666.46671 |
476 | FluidCooler:TwoSpeed | CENTRAL TOWER | Fluid cooler UA value at high fan speed based on nominal capacity input [W/K] | 58281.61204 |
477 | FluidCooler:TwoSpeed | CENTRAL TOWER | Air Flow Rate at Low Fan Speed [m3/s] | 69833.23335 |
478 | FluidCooler:TwoSpeed | CENTRAL TOWER | Fan Power at Low Fan Speed [W] | 7879.72339 |
479 | FluidCooler:TwoSpeed | CENTRAL TOWER | U-factor Times Area Value at Low Fan Speed [W/C] | 21315.54983 |
480 | Boiler:HotWater | CENTRAL BOILER | Design Size Nominal Capacity [W] | 558242.85472 |
481 | Boiler:HotWater | CENTRAL BOILER | User-Specified Nominal Capacity [W] | 547194.34000 |
482 | Boiler:HotWater | CENTRAL BOILER | Design Size Design Water Flow Rate [m3/s] | 1.35524E-002 |
483 | PlantLoop | SWHSYS1 | Maximum Loop Flow Rate [m3/s] | 4.40000E-004 |
484 | PlantLoop | SWHSYS1 | Plant Loop Volume [m3] | 5.28000E-002 |
485 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Flow Rate [m3/s] | 4.40000E-004 |
486 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Power Consumption [W] | 5.95776 |
487 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | Use Side Design Flow Rate [m3/s] | 4.40000E-004 |
488 | CondenserLoop | TOWERWATERSYS | Maximum Loop Flow Rate [m3/s] | 0.13101 |
489 | CondenserLoop | TOWERWATERSYS | Condenser Loop Volume [m3] | 15.72093 |
490 | HeaderedPumps:VariableSpeed | TOWERWATERSYS PUMP | Design Flow Rate [m3/s] | 0.13101 |
491 | HeaderedPumps:VariableSpeed | TOWERWATERSYS PUMP | Design Power Consumption [W] | 39456.67430 |
492 | CoolingTower:VariableSpeed | TOWERWATERSYS COOLTOWER 1 | Design Air Flow Rate [m3/s] | 52.83405 |
493 | CoolingTower:VariableSpeed | TOWERWATERSYS COOLTOWER 1 | Nominal Capacity [W] | 1571052.58871 |
494 | CoolingTower:VariableSpeed | TOWERWATERSYS COOLTOWER 1 | Air Flow Rate in free convection regime [m3/s] | 10.56681 |
495 | CoolingTower:VariableSpeed | TOWERWATERSYS COOLTOWER 1 | Tower capacity in free convection regime at design conditions [W] | 196381.57359 |
496 | CoolingTower:VariableSpeed | TOWERWATERSYS COOLTOWER 2 | Design Air Flow Rate [m3/s] | 52.83405 |
497 | CoolingTower:VariableSpeed | TOWERWATERSYS COOLTOWER 2 | Nominal Capacity [W] | 1571052.58871 |
498 | CoolingTower:VariableSpeed | TOWERWATERSYS COOLTOWER 2 | Air Flow Rate in free convection regime [m3/s] | 10.56681 |
499 | CoolingTower:VariableSpeed | TOWERWATERSYS COOLTOWER 2 | Tower capacity in free convection regime at design conditions [W] | 196381.57359 |
500 | PlantEquipmentOperation:ComponentSetPoint | WSHPPLANT OPERATION SCHEME | Design Water Flow Rate [m3/s] Equipment # 47 | 6.80375E-002 |
501 | PlantEquipmentOperation:ComponentSetPoint | WSHPPLANT OPERATION SCHEME | Design Water Flow Rate [m3/s] Equipment # 47 | 6.80375E-002 |
Component Type | Name | Nominal Total Capacity {W} | |
1 | Coil:Heating:Water | CORE_BOTTOM VAV BOX REHEAT COIL | 27224.16 |
2 | Coil:Heating:Water | CORE_MID VAV BOX REHEAT COIL | 517332.81 |
3 | Coil:Heating:Water | CORE_TOP VAV BOX REHEAT COIL | 109097.81 |
4 | Coil:Heating:Water | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | 18948.52 |
5 | Coil:Heating:Water | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | 12998.53 |
6 | Coil:Heating:Water | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | 20795.36 |
7 | Coil:Heating:Water | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | 11812.57 |
8 | Coil:Heating:Water | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | 272000.17 |
9 | Coil:Heating:Water | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | 180400.35 |
10 | Coil:Heating:Water | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | 274791.54 |
11 | Coil:Heating:Water | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | 176392.54 |
12 | Coil:Heating:Water | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | 36033.82 |
13 | Coil:Heating:Water | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | 23775.13 |
14 | Coil:Heating:Water | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | 36395.52 |
15 | Coil:Heating:Water | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | 23685.80 |
16 | Coil:Heating:Water | VAV_BOT WITH REHEAT HEATING COIL | 80429.27 |
17 | Coil:Heating:Water | VAV_MID WITH REHEAT HEATING COIL | 789052.45 |
18 | Coil:Heating:Water | VAV_TOP WITH REHEAT HEATING COIL | 81101.63 |
19 | Coil:Heating:Water | CAV_BAS HEATING COIL | 237408.52 |
Component Type | Name | Nominal Total Capacity {W} | Nominal Sensible Capacity {W} | Nominal Latent Capacity {W} | Nominal Sensible Heat Ratio | Nominal Coil UA Value {W/C} | Nominal Coil Surface Area {m2} | |
1 | Coil:Cooling:Water | VAV_BOT WITH REHEAT COOLING COIL | 256563.43 | 172774.61 | 83788.82 | 0.67 | 27581.77 | 279.75 |
2 | Coil:Cooling:Water | VAV_MID WITH REHEAT COOLING COIL | 2413123.81 | 1618216.42 | 794907.40 | 0.67 | 259548.48 | 2632.48 |
3 | Coil:Cooling:Water | VAV_TOP WITH REHEAT COOLING COIL | 254940.73 | 171670.93 | 83269.80 | 0.67 | 27416.21 | 278.07 |
4 | Coil:Cooling:Water | CAV_BAS COOLING COIL | 144606.59 | 98398.98 | 46207.61 | 0.68 | 15157.98 | 153.74 |
Component Type | Component Name | IPLV in SI Units {W/W} | IPLV in IP Units {Btu/W-h} | |
1 | Chiller:Electric:ReformulatedEIR | COOLSYS1 CHILLER1 | 6.84 | 23.33 |
2 | Chiller:Electric:ReformulatedEIR | COOLSYS1 CHILLER2 | 6.84 | 23.33 |
Zone Name | # Surfaces | |
1 | BASEMENT | 10 |
2 | CORE_BOTTOM | 8 |
3 | CORE_MID | 7 |
4 | CORE_TOP | 7 |
5 | PERIMETER_BOT_ZN_3 | 18 |
6 | PERIMETER_BOT_ZN_2 | 12 |
7 | PERIMETER_BOT_ZN_1 | 18 |
8 | PERIMETER_BOT_ZN_4 | 12 |
9 | PERIMETER_MID_ZN_3 | 9 |
10 | PERIMETER_MID_ZN_2 | 8 |
11 | PERIMETER_MID_ZN_1 | 9 |
12 | PERIMETER_MID_ZN_4 | 8 |
13 | PERIMETER_TOP_ZN_3 | 9 |
14 | PERIMETER_TOP_ZN_2 | 8 |
15 | PERIMETER_TOP_ZN_1 | 9 |
16 | PERIMETER_TOP_ZN_4 | 8 |
17 | GROUNDFLOOR_PLENUM | 11 |
18 | MIDFLOOR_PLENUM | 11 |
19 | TOPFLOOR_PLENUM | 11 |
20 | DATACENTER_BOT_ZN_6 | 6 |
21 | DATACENTER_MID_ZN_6 | 6 |
22 | DATACENTER_TOP_ZN_6 | 6 |
23 | DATACENTER_BASEMENT_ZN_6 | 10 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | BASEMENT_WALL_EAST | Wall | CTF - ConductionTransferFunction | BASEMENT_WALL_EAST_CFACTOR | 0.354 | 0.336 | 118.87 | 118.87 | 118.87 | 90.00 | 90.00 | 48.74 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | BASEMENT_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | BASEMENT_WALL_SOUTH_CFACTOR | 0.354 | 0.336 | 139.09 | 139.09 | 139.09 | 180.00 | 90.00 | 57.03 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | BASEMENT_WALL_NORTH | Wall | CTF - ConductionTransferFunction | BASEMENT_WALL_NORTH_CFACTOR | 0.354 | 0.336 | 139.09 | 139.09 | 139.09 | 0.00 | 90.00 | 57.03 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | BASEMENT_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.87 | 118.87 | 118.87 | 270.00 | 90.00 | 48.74 | 2.44 | 0.00 | DATACENTER_BASEMENT_ZN_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
5 | BASEMENT_FLOOR | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 2779.43 | 2779.43 | 2779.43 | 0.00 | 180.00 | 57.03 | 48.74 | 0.00 | BASEMENT_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.00 | 1.00 | 0.00 | 4 | ||
6 | PERIMETER_BOT_ZN_2_FLOOR-PPAUTOCREATEOTHER | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 201.98 | 201.98 | 201.98 | 225.00 | 0.00 | 6.47 | 39.59 | 0.00 | PERIMETER_BOT_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
7 | PERIMETER_BOT_ZN_1_FLOOR-PPAUTOCREATEOTHER | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 250.34 | 250.34 | 250.34 | 180.00 | 0.00 | 57.03 | 4.57 | 0.00 | PERIMETER_BOT_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
8 | CORE_BOT_ZN_5_FLOOR-PPAUTOCREATEOTHER | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 2076.77 | 2076.77 | 2076.77 | 180.00 | 0.00 | 52.45 | 39.59 | 0.00 | CORE_BOT_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
9 | PERIMETER_BOT_ZN_3_FLOOR-PPAUTOCREATEOTHER | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 250.34 | 250.34 | 250.34 | 180.00 | 0.00 | 52.45 | 4.57 | 0.00 | PERIMETER_BOT_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
10 | BASEMENT_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 7126.21 | 7126.21 | 7126.21 | 0.00 | 90.00 | 7126.21 | 1.00 | 0.00 | BASEMENT_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
11 | CORE_BOT_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 173.00 | 173.00 | 173.00 | 180.00 | 90.00 | 63.05 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | CORE_BOT_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 270.00 | 90.00 | 39.59 | 2.74 | 0.00 | DATACENTER_BOT_ZN_6_WALL_EAST-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
13 | CORE_BOT_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 173.00 | 173.00 | 173.00 | 0.00 | 90.00 | 63.05 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
14 | CORE_BOT_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 90.00 | 90.00 | 39.59 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_EAST-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
15 | DATACENTER_BASEMENT_ZN_6_CEILING-CORE_BOT_ZN_5-PPAUTOCREATEOTHER | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 419.30 | 419.30 | 419.30 | 0.00 | 180.00 | 10.59 | 39.59 | 0.00 | DATACENTER_BASEMENT_ZN_6_CEILING-CORE_BOT_ZN_5 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.00 | 1.00 | 0.00 | 4 | ||
16 | CORE_BOT_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 2076.82 | 2076.82 | 2076.82 | 0.00 | 180.00 | 52.46 | 39.59 | 0.00 | CORE_BOT_ZN_5_FLOOR-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.00 | 1.00 | 0.00 | 4 | ||
17 | CORE_BOT_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 2496.12 | 2496.12 | 2496.12 | 180.00 | 0.00 | 63.05 | 39.59 | 0.00 | iz-CORE_BOT_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
18 | CORE_BOTTOM_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 5064.65 | 5064.65 | 5064.65 | 0.00 | 90.00 | 5064.65 | 1.00 | 0.00 | CORE_BOTTOM_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
19 | CORE_MID_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 173.00 | 173.00 | 173.00 | 180.00 | 90.00 | 63.05 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | CORE_MID_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 270.00 | 90.00 | 39.59 | 2.74 | 0.00 | DATACENTER_MID_ZN_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | CORE_MID_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 173.00 | 173.00 | 173.00 | 0.00 | 90.00 | 63.05 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
22 | CORE_MID_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 90.00 | 90.00 | 39.59 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_EAST-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
23 | CORE_MID_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 2496.12 | 2496.12 | 2496.12 | 0.00 | 180.00 | 63.05 | 39.59 | 0.00 | CORE_MID_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
24 | CORE_MID_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 2496.12 | 2496.12 | 2496.12 | 180.00 | 0.00 | 63.05 | 39.59 | 0.00 | iz-CORE_MID_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
25 | CORE_MID_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 5064.65 | 5064.65 | 5064.65 | 0.00 | 90.00 | 5064.65 | 1.00 | 0.00 | CORE_MID_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
26 | CORE_TOP_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 173.00 | 173.00 | 173.00 | 180.00 | 90.00 | 63.05 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
27 | CORE_TOP_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 270.00 | 90.00 | 39.59 | 2.74 | 0.00 | DATACENTER_TOP_ZN_6_WALL_WEST-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
28 | CORE_TOP_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 173.00 | 173.00 | 173.00 | 0.00 | 90.00 | 63.05 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
29 | CORE_TOP_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 90.00 | 90.00 | 39.59 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_EAST-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
30 | CORE_TOP_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 2496.12 | 2496.12 | 2496.12 | 0.00 | 180.00 | 63.05 | 39.59 | 0.00 | CORE_TOP_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
31 | CORE_TOP_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 2496.12 | 2496.12 | 2496.12 | 180.00 | 0.00 | 63.05 | 39.59 | 0.00 | iz-CORE_TOP_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
32 | CORE_TOP_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 5064.65 | 5064.65 | 5064.65 | 0.00 | 90.00 | 5064.65 | 1.00 | 0.00 | CORE_TOP_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
33 | PERIMETER_BOT_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.078 | 0.928 | 105.88 | 200.61 | 105.88 | 0.00 | 90.00 | 73.11 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
34 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_NORTH_0.45 | N/A | 1.661 | No | 17.38 | 17.38 | 17.38 | 0.00 | 90.00 | 13.65 | 1.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
35 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_NORTH_0.45 | N/A | 1.661 | No | 17.38 | 17.38 | 17.38 | 0.00 | 90.00 | 13.65 | 1.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
36 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_NORTH_0.45 | N/A | 1.661 | No | 17.38 | 17.38 | 17.38 | 0.00 | 90.00 | 13.65 | 1.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
37 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_NORTH_0.45 | N/A | 1.661 | No | 17.38 | 17.38 | 17.38 | 0.00 | 90.00 | 13.65 | 1.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
38 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_NORTH_0.45 | N/A | 1.661 | No | 17.38 | 17.38 | 17.38 | 0.00 | 90.00 | 13.65 | 1.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
39 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | Door | PERIMETER_BOT_ZN_3_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
40 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | Door | PERIMETER_BOT_ZN_3_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
41 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR3 | Door | PERIMETER_BOT_ZN_3_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
42 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR4 | Door | PERIMETER_BOT_ZN_3_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
43 | PERIMETER_BOT_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_3_WALL_WEST-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
44 | CORE_BOT_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 173.00 | 173.00 | 173.00 | 180.00 | 90.00 | 63.05 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
45 | PERIMETER_BOT_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
46 | DATACENTER_BOT_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 2.51 | 2.51 | 2.51 | 180.00 | 90.00 | 0.91 | 2.74 | 0.00 | DATACENTER_BOT_ZN_6_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
47 | PERIMETER_BOT_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 250.34 | 250.34 | 250.34 | 0.00 | 180.00 | 52.46 | 6.47 | 0.00 | PERIMETER_BOT_ZN_3_FLOOR-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
48 | DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_3-PPAUTOCREATEOTHER | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 63.07 | 63.07 | 63.07 | 0.00 | 180.00 | 11.51 | 4.57 | 0.00 | DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.00 | 1.00 | 0.00 | 4 | ||
49 | PERIMETER_BOT_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 313.41 | 313.41 | 313.41 | 180.00 | 0.00 | 63.96 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
50 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 626.83 | 626.83 | 626.83 | 0.00 | 90.00 | 626.83 | 1.00 | 0.00 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
51 | PERIMETER_BOT_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.078 | 0.928 | 71.89 | 133.74 | 71.89 | 90.00 | 90.00 | 48.74 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
52 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | Window | PERIMETER_BOT_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_EAST_0.45 | N/A | 1.661 | No | 19.32 | 19.32 | 19.32 | 90.00 | 90.00 | 15.43 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
53 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | Window | PERIMETER_BOT_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_EAST_0.45 | N/A | 1.661 | No | 19.32 | 19.32 | 19.32 | 90.00 | 90.00 | 15.43 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
54 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | Window | PERIMETER_BOT_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_EAST_0.45 | N/A | 1.661 | No | 19.32 | 19.32 | 19.32 | 90.00 | 90.00 | 15.43 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
55 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR1 | Door | PERIMETER_BOT_ZN_2_WALL_EAST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
56 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR2 | Door | PERIMETER_BOT_ZN_2_WALL_EAST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
57 | PERIMETER_BOT_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
58 | CORE_BOT_ZN_5_WALL_EAST-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 270.00 | 90.00 | 39.59 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
59 | PERIMETER_BOT_ZN_1_WALL_EAST-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
60 | PERIMETER_BOT_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 201.98 | 201.98 | 201.98 | 45.00 | 180.00 | 6.47 | 48.74 | 0.00 | PERIMETER_BOT_ZN_2_FLOOR-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
61 | PERIMETER_BOT_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 201.98 | 201.98 | 201.98 | 225.00 | 0.00 | 6.47 | 39.59 | 0.00 | iz-PERIMETER_BOT_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
62 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 403.95 | 403.95 | 403.95 | 0.00 | 90.00 | 403.95 | 1.00 | 0.00 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
63 | PERIMETER_BOT_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.078 | 0.928 | 105.88 | 200.61 | 105.88 | 180.00 | 90.00 | 73.11 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
64 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_SOUTH_0.45 | N/A | 1.661 | No | 17.38 | 17.38 | 17.38 | 180.00 | 90.00 | 13.65 | 1.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
65 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_SOUTH_0.45 | N/A | 1.661 | No | 17.38 | 17.38 | 17.38 | 180.00 | 90.00 | 13.65 | 1.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
66 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_SOUTH_0.45 | N/A | 1.661 | No | 17.38 | 17.38 | 17.38 | 180.00 | 90.00 | 13.65 | 1.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
67 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_SOUTH_0.45 | N/A | 1.661 | No | 17.38 | 17.38 | 17.38 | 180.00 | 90.00 | 13.65 | 1.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
68 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_SOUTH_0.45 | N/A | 1.661 | No | 17.38 | 17.38 | 17.38 | 180.00 | 90.00 | 13.65 | 1.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
69 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | Door | PERIMETER_BOT_ZN_1_WALL_SOUTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
70 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | Door | PERIMETER_BOT_ZN_1_WALL_SOUTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
71 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR3 | Door | PERIMETER_BOT_ZN_1_WALL_SOUTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
72 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR4 | Door | PERIMETER_BOT_ZN_1_WALL_SOUTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
73 | PERIMETER_BOT_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_1_WALL_EAST-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
74 | DATACENTER_BOT_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 2.51 | 2.51 | 2.51 | 0.00 | 90.00 | 0.91 | 2.74 | 0.00 | DATACENTER_BOT_ZN_6_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
75 | PERIMETER_BOT_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
76 | CORE_BOT_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 173.00 | 173.00 | 173.00 | 0.00 | 90.00 | 63.05 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
77 | DATACENTER_BASEMENT_ZN_6-PERIMETER_BOT_ZN_1-PPAUTOCREATEOTHER | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 63.07 | 63.07 | 63.07 | 0.00 | 180.00 | 16.08 | 4.57 | 0.00 | DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.00 | 1.00 | 0.00 | 4 | ||
78 | PERIMETER_BOT_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 250.35 | 250.35 | 250.35 | 0.00 | 180.00 | 57.03 | 6.47 | 0.00 | PERIMETER_BOT_ZN_1_FLOOR-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.00 | 1.00 | 0.00 | 4 | ||
79 | PERIMETER_BOT_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 313.42 | 313.42 | 313.42 | 180.00 | 0.00 | 73.11 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
80 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 626.84 | 626.84 | 626.84 | 0.00 | 90.00 | 626.84 | 1.00 | 0.00 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
81 | PERIMETER_BOT_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.078 | 0.928 | 71.89 | 133.74 | 71.89 | 270.00 | 90.00 | 48.74 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
82 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | Window | PERIMETER_BOT_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_WEST_0.45 | N/A | 1.661 | No | 19.32 | 19.32 | 19.32 | 270.00 | 90.00 | 15.43 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
83 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | Window | PERIMETER_BOT_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_WEST_0.45 | N/A | 1.661 | No | 19.32 | 19.32 | 19.32 | 270.00 | 90.00 | 15.43 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
84 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | Window | PERIMETER_BOT_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_WEST_0.45 | N/A | 1.661 | No | 19.32 | 19.32 | 19.32 | 270.00 | 90.00 | 15.43 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
85 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR1 | Door | PERIMETER_BOT_ZN_4_WALL_WEST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
86 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR2 | Door | PERIMETER_BOT_ZN_4_WALL_WEST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
87 | PERIMETER_BOT_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
88 | DATACENTER_BOT_ZN_6_WALL_WEST-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 90.00 | 90.00 | 39.59 | 2.74 | 0.00 | DATACENTER_BOT_ZN_6_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
89 | PERIMETER_BOT_ZN_3_WALL_WEST-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
90 | PERIMETER_BOT_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 201.98 | 201.98 | 201.98 | 315.00 | 180.00 | 6.47 | 39.59 | 0.00 | PERIMETER_BOT_ZN_4_FLOOR-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.00 | 1.00 | 0.00 | 4 | ||
91 | PERIMETER_BOT_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 201.98 | 201.98 | 201.98 | 135.00 | 0.00 | 6.47 | 48.74 | 0.00 | iz-PERIMETER_BOT_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
92 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 403.95 | 403.95 | 403.95 | 0.00 | 90.00 | 403.95 | 1.00 | 0.00 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
93 | PERIMETER_MID_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.004 | 0.873 | 113.68 | 200.61 | 113.68 | 0.00 | 90.00 | 73.11 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
94 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | Window | PERIMETER_MID_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_NORTH_0.45 | N/A | 1.661 | No | 86.92 | 86.92 | 86.92 | 0.00 | 90.00 | 73.11 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
95 | PERIMETER_MID_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_3_WALL_WEST-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
96 | CORE_MID_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 173.00 | 173.00 | 173.00 | 180.00 | 90.00 | 63.05 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
97 | PERIMETER_MID_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
98 | DATACENTER_MID_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 2.51 | 2.51 | 2.51 | 180.00 | 90.00 | 0.91 | 2.74 | 0.00 | DATACENTER_MID_ZN_6_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
99 | PERIMETER_MID_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 313.41 | 313.41 | 313.41 | 0.00 | 180.00 | 63.96 | 6.47 | 0.00 | PERIMETER_MID_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
100 | PERIMETER_MID_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 313.41 | 313.41 | 313.41 | 180.00 | 0.00 | 63.96 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
101 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 626.83 | 626.83 | 626.83 | 0.00 | 90.00 | 626.83 | 1.00 | 0.00 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
102 | PERIMETER_MID_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.004 | 0.873 | 75.79 | 133.74 | 75.79 | 90.00 | 90.00 | 48.74 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
103 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | Window | PERIMETER_MID_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_EAST_0.45 | N/A | 1.661 | No | 57.95 | 57.95 | 57.95 | 90.00 | 90.00 | 48.74 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
104 | PERIMETER_MID_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | CORE_MID_ZN_5_WALL_EAST-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 270.00 | 90.00 | 39.59 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
106 | PERIMETER_MID_ZN_1_WALL_EAST-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
107 | PERIMETER_MID_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 201.98 | 201.98 | 201.98 | 45.00 | 180.00 | 6.47 | 48.74 | 0.00 | PERIMETER_MID_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
108 | PERIMETER_MID_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 201.98 | 201.98 | 201.98 | 225.00 | 0.00 | 6.47 | 39.59 | 0.00 | iz-PERIMETER_MID_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
109 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 403.95 | 403.95 | 403.95 | 0.00 | 90.00 | 403.95 | 1.00 | 0.00 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
110 | PERIMETER_MID_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_1_WALL_EAST-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
111 | PERIMETER_MID_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.004 | 0.873 | 113.68 | 200.61 | 113.68 | 180.00 | 90.00 | 73.11 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
112 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | Window | PERIMETER_MID_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_SOUTH_0.45 | N/A | 1.661 | No | 86.92 | 86.92 | 86.92 | 180.00 | 90.00 | 73.11 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
113 | DATACENTER_MID_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 2.51 | 2.51 | 2.51 | 0.00 | 90.00 | 0.91 | 2.74 | 0.00 | DATACENTER_MID_ZN_6_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
114 | PERIMETER_MID_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
115 | CORE_MID_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 173.00 | 173.00 | 173.00 | 0.00 | 90.00 | 63.05 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
116 | PERIMETER_MID_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 313.42 | 313.42 | 313.42 | 0.00 | 180.00 | 73.11 | 6.47 | 0.00 | PERIMETER_MID_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
117 | PERIMETER_MID_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 313.42 | 313.42 | 313.42 | 180.00 | 0.00 | 73.11 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
118 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 626.84 | 626.84 | 626.84 | 0.00 | 90.00 | 626.84 | 1.00 | 0.00 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
119 | PERIMETER_MID_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.004 | 0.873 | 75.79 | 133.74 | 75.79 | 270.00 | 90.00 | 48.74 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
120 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | Window | PERIMETER_MID_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_WEST_0.45 | N/A | 1.661 | No | 57.95 | 57.95 | 57.95 | 270.00 | 90.00 | 48.74 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
121 | PERIMETER_MID_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
122 | DATACENTER_MID_ZN_6_WALL_WEST-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 90.00 | 90.00 | 39.59 | 2.74 | 0.00 | DATACENTER_MID_ZN_6_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
123 | PERIMETER_MID_ZN_3_WALL_WEST-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
124 | PERIMETER_MID_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 201.98 | 201.98 | 201.98 | 315.00 | 180.00 | 6.47 | 39.59 | 0.00 | PERIMETER_MID_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
125 | PERIMETER_MID_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 201.98 | 201.98 | 201.98 | 135.00 | 0.00 | 6.47 | 48.74 | 0.00 | iz-PERIMETER_MID_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
126 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 403.95 | 403.95 | 403.95 | 0.00 | 90.00 | 403.95 | 1.00 | 0.00 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
127 | PERIMETER_TOP_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.410 | 1.164 | 113.68 | 200.61 | 113.68 | 0.00 | 90.00 | 73.11 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
128 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | Window | PERIMETER_TOP_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_NORTH_0.45 | N/A | 1.661 | No | 86.92 | 86.92 | 86.92 | 0.00 | 90.00 | 73.11 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
129 | PERIMETER_TOP_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_3_WALL_WEST-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
130 | CORE_TOP_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 173.00 | 173.00 | 173.00 | 180.00 | 90.00 | 63.05 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
131 | PERIMETER_TOP_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
132 | DATACENTER_TOP_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 2.51 | 2.51 | 2.51 | 180.00 | 90.00 | 0.91 | 2.74 | 0.00 | DATACENTER_TOP_ZN_6_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
133 | PERIMETER_TOP_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 313.41 | 313.41 | 313.41 | 0.00 | 180.00 | 63.96 | 6.47 | 0.00 | PERIMETER_TOP_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
134 | PERIMETER_TOP_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 313.41 | 313.41 | 313.41 | 180.00 | 0.00 | 63.96 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
135 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 626.83 | 626.83 | 626.83 | 0.00 | 90.00 | 626.83 | 1.00 | 0.00 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
136 | PERIMETER_TOP_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.410 | 1.164 | 75.79 | 133.74 | 75.79 | 90.00 | 90.00 | 48.74 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
137 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | Window | PERIMETER_TOP_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_EAST_0.45 | N/A | 1.661 | No | 57.95 | 57.95 | 57.95 | 90.00 | 90.00 | 48.74 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
138 | PERIMETER_TOP_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
139 | CORE_TOP_ZN_5_WALL_EAST-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 270.00 | 90.00 | 39.59 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
140 | INT-PER3S-NE-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | INT-PER3S-NE | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
141 | PERIMETER_TOP_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 201.98 | 201.98 | 201.98 | 45.00 | 180.00 | 6.47 | 48.74 | 0.00 | PERIMETER_TOP_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
142 | PERIMETER_TOP_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 201.98 | 201.98 | 201.98 | 225.00 | 0.00 | 6.47 | 39.59 | 0.00 | iz-PERIMETER_TOP_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
143 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 403.95 | 403.95 | 403.95 | 0.00 | 90.00 | 403.95 | 1.00 | 0.00 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
144 | PERIMETER_TOP_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.410 | 1.164 | 113.68 | 200.61 | 113.68 | 180.00 | 90.00 | 73.11 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
145 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | Window | PERIMETER_TOP_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_SOUTH_0.45 | N/A | 1.661 | No | 86.92 | 86.92 | 86.92 | 180.00 | 90.00 | 73.11 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
146 | INT-PER3S-NE | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | INT-PER3S-NE-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
147 | DATACENTER_TOP_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 2.51 | 2.51 | 2.51 | 0.00 | 90.00 | 0.91 | 2.74 | 0.00 | DATACENTER_TOP_ZN_6_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
148 | PERIMETER_TOP_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
149 | CORE_TOP_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 173.00 | 173.00 | 173.00 | 0.00 | 90.00 | 63.05 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
150 | PERIMETER_TOP_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 313.42 | 313.42 | 313.42 | 0.00 | 180.00 | 73.11 | 6.47 | 0.00 | PERIMETER_TOP_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
151 | PERIMETER_TOP_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 313.42 | 313.42 | 313.42 | 180.00 | 0.00 | 73.11 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
152 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 626.84 | 626.84 | 626.84 | 0.00 | 90.00 | 626.84 | 1.00 | 0.00 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
153 | PERIMETER_TOP_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.410 | 1.164 | 75.79 | 133.74 | 75.79 | 270.00 | 90.00 | 48.74 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
154 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | Window | PERIMETER_TOP_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.2925_SHGC_WEST_0.45 | N/A | 1.661 | No | 57.95 | 57.95 | 57.95 | 270.00 | 90.00 | 48.74 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
155 | PERIMETER_TOP_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
156 | DATACENTER_TOP_ZN_6_WALL_WEST-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 90.00 | 90.00 | 39.59 | 2.74 | 0.00 | DATACENTER_TOP_ZN_6_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
157 | PERIMETER_TOP_ZN_3_WALL_WEST-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.75 | 17.75 | 17.75 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
158 | PERIMETER_TOP_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 201.98 | 201.98 | 201.98 | 315.00 | 180.00 | 6.47 | 39.59 | 0.00 | PERIMETER_TOP_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
159 | PERIMETER_TOP_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 201.98 | 201.98 | 201.98 | 135.00 | 0.00 | 6.47 | 48.74 | 0.00 | iz-PERIMETER_TOP_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
160 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 403.95 | 403.95 | 403.95 | 0.00 | 90.00 | 403.95 | 1.00 | 0.00 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
161 | GROUNDFLOOR_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.078 | 0.928 | 89.13 | 89.13 | 89.13 | 0.00 | 90.00 | 73.11 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
162 | GROUNDFLOOR_PLENUM_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.078 | 0.928 | 59.42 | 59.42 | 59.42 | 270.00 | 90.00 | 48.74 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
163 | GROUNDFLOOR_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.078 | 0.928 | 89.13 | 89.13 | 89.13 | 180.00 | 90.00 | 73.11 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
164 | GROUNDFLOOR_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.078 | 0.928 | 59.42 | 59.42 | 59.42 | 90.00 | 90.00 | 48.74 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
165 | iz-CORE_BOT_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 2496.12 | 2496.12 | 2496.12 | 0.00 | 180.00 | 63.05 | 39.59 | 0.00 | CORE_BOT_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
166 | iz-PERIMETER_BOT_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 313.41 | 313.41 | 313.41 | 0.00 | 180.00 | 63.96 | 6.47 | 0.00 | PERIMETER_BOT_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
167 | iz-PERIMETER_BOT_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 201.98 | 201.98 | 201.98 | 45.00 | 180.00 | 6.47 | 48.74 | 0.00 | PERIMETER_BOT_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
168 | iz-PERIMETER_BOT_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 313.42 | 313.42 | 313.42 | 0.00 | 180.00 | 73.11 | 6.47 | 0.00 | PERIMETER_BOT_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
169 | iz-PERIMETER_BOT_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 201.98 | 201.98 | 201.98 | 315.00 | 180.00 | 6.47 | 39.59 | 0.00 | PERIMETER_BOT_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
170 | iz-DATACENTER_BOT_ZN_6_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 36.20 | 36.20 | 36.20 | 0.00 | 180.00 | 0.91 | 39.59 | 0.00 | DATACENTER_BOT_ZN_6_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
171 | GROUNDFLOOR_PLENUM_CEILING | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 3563.11 | 3563.11 | 3563.11 | 180.00 | 0.00 | 73.11 | 48.74 | 0.00 | GROUNDFLOOR_PLENUM_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
172 | MIDFLOOR_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.004 | 0.873 | 89.13 | 89.13 | 89.13 | 0.00 | 90.00 | 73.11 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
173 | MIDFLOOR_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.004 | 0.873 | 59.42 | 59.42 | 59.42 | 270.00 | 90.00 | 48.74 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
174 | MIDFLOOR_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.004 | 0.873 | 89.13 | 89.13 | 89.13 | 180.00 | 90.00 | 73.11 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
175 | MIDFLOOR_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.004 | 0.873 | 59.42 | 59.42 | 59.42 | 90.00 | 90.00 | 48.74 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
176 | iz-CORE_MID_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 2496.12 | 2496.12 | 2496.12 | 0.00 | 180.00 | 63.05 | 39.59 | 0.00 | CORE_MID_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
177 | iz-PERIMETER_MID_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 313.41 | 313.41 | 313.41 | 0.00 | 180.00 | 63.96 | 6.47 | 0.00 | PERIMETER_MID_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
178 | iz-PERIMETER_MID_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 201.98 | 201.98 | 201.98 | 45.00 | 180.00 | 6.47 | 48.74 | 0.00 | PERIMETER_MID_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
179 | iz-PERIMETER_MID_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 313.42 | 313.42 | 313.42 | 0.00 | 180.00 | 73.11 | 6.47 | 0.00 | PERIMETER_MID_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
180 | iz-PERIMETER_MID_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 201.98 | 201.98 | 201.98 | 315.00 | 180.00 | 6.47 | 39.59 | 0.00 | PERIMETER_MID_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
181 | iz-DATACENTER_MID_ZN_6_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 36.20 | 36.20 | 36.20 | 0.00 | 180.00 | 0.91 | 39.59 | 0.00 | DATACENTER_MID_ZN_6_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
182 | MIDFLOOR_PLENUM_CEILING | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 3563.11 | 3563.11 | 3563.11 | 180.00 | 0.00 | 73.11 | 48.74 | 0.00 | MIDFLOOR_PLENUM_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
183 | TOPFLOOR_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.410 | 1.164 | 89.13 | 89.13 | 89.13 | 180.00 | 90.00 | 73.11 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
184 | TOPFLOOR_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.410 | 1.164 | 59.42 | 59.42 | 59.42 | 90.00 | 90.00 | 48.74 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
185 | TOPFLOOR_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.410 | 1.164 | 59.42 | 59.42 | 59.42 | 270.00 | 90.00 | 48.74 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
186 | TOPFLOOR_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.410 | 1.164 | 89.13 | 89.13 | 89.13 | 0.00 | 90.00 | 73.11 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
187 | iz-CORE_TOP_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 2496.12 | 2496.12 | 2496.12 | 0.00 | 180.00 | 63.05 | 39.59 | 0.00 | CORE_TOP_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
188 | iz-PERIMETER_TOP_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 313.41 | 313.41 | 313.41 | 0.00 | 180.00 | 63.96 | 6.47 | 0.00 | PERIMETER_TOP_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
189 | iz-PERIMETER_TOP_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 201.98 | 201.98 | 201.98 | 45.00 | 180.00 | 6.47 | 48.74 | 0.00 | PERIMETER_TOP_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
190 | iz-PERIMETER_TOP_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 313.42 | 313.42 | 313.42 | 0.00 | 180.00 | 73.11 | 6.47 | 0.00 | PERIMETER_TOP_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
191 | iz-PERIMETER_TOP_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 201.98 | 201.98 | 201.98 | 315.00 | 180.00 | 6.47 | 39.59 | 0.00 | PERIMETER_TOP_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
192 | iz-DATACENTER_TOP_ZN_6_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 36.20 | 36.20 | 36.20 | 0.00 | 180.00 | 0.91 | 39.59 | 0.00 | DATACENTER_TOP_ZN_6_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
193 | BUILDING_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.163 | 0.158 | 3563.11 | 3563.11 | 3563.11 | 180.00 | 0.00 | 73.11 | 48.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
194 | DATACENTER_BOT_ZN_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 2.51 | 2.51 | 2.51 | 0.00 | 90.00 | 0.91 | 2.74 | 0.00 | DATACENTER_BOT_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
195 | DATACENTER_BOT_ZN_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 2.51 | 2.51 | 2.51 | 180.00 | 90.00 | 0.91 | 2.74 | 0.00 | DATACENTER_BOT_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
196 | DATACENTER_BOT_ZN_6_WALL_EAST-PPAUTOCREATEOTHER | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 90.00 | 90.00 | 39.59 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
197 | DATACENTER_BOT_ZN_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 270.00 | 90.00 | 39.59 | 2.74 | 0.00 | DATACENTER_BOT_ZN_6_WALL_WEST-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
198 | DATACENTER_BOT_ZN_6_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 36.20 | 36.20 | 36.20 | 0.00 | 180.00 | 0.91 | 39.59 | 0.00 | DATACENTER_BOT_ZN_6_FLOOR-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.00 | 1.00 | 0.00 | 4 | ||
199 | DATACENTER_BOT_ZN_6_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 36.20 | 36.20 | 36.20 | 180.00 | 0.00 | 0.91 | 39.59 | 0.00 | iz-DATACENTER_BOT_ZN_6_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
200 | DATACENTER_MID_ZN_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 270.00 | 90.00 | 39.59 | 2.74 | 0.00 | DATACENTER_MID_ZN_6_WALL_WEST-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
201 | DATACENTER_MID_ZN_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 2.51 | 2.51 | 2.51 | 180.00 | 90.00 | 0.91 | 2.74 | 0.00 | DATACENTER_MID_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
202 | DATACENTER_MID_ZN_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 90.00 | 90.00 | 39.59 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
203 | DATACENTER_MID_ZN_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 2.51 | 2.51 | 2.51 | 0.00 | 90.00 | 0.91 | 2.74 | 0.00 | DATACENTER_MID_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
204 | DATACENTER_MID_ZN_6_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 36.20 | 36.20 | 36.20 | 0.00 | 180.00 | 0.91 | 39.59 | 0.00 | DATACENTER_MID_ZN_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.00 | 1.00 | 0.00 | 4 | ||
205 | DATACENTER_MID_ZN_6_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 36.20 | 36.20 | 36.20 | 180.00 | 0.00 | 0.91 | 39.59 | 0.00 | iz-DATACENTER_MID_ZN_6_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
206 | DATACENTER_TOP_ZN_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 90.00 | 90.00 | 39.59 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
207 | DATACENTER_TOP_ZN_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 108.64 | 108.64 | 108.64 | 270.00 | 90.00 | 39.59 | 2.74 | 0.00 | DATACENTER_TOP_ZN_6_WALL_WEST-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
208 | DATACENTER_TOP_ZN_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 2.51 | 2.51 | 2.51 | 180.00 | 90.00 | 0.91 | 2.74 | 0.00 | DATACENTER_TOP_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
209 | DATACENTER_TOP_ZN_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 2.51 | 2.51 | 2.51 | 0.00 | 90.00 | 0.91 | 2.74 | 0.00 | DATACENTER_TOP_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
210 | DATACENTER_TOP_ZN_6_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 36.20 | 36.20 | 36.20 | 0.00 | 180.00 | 0.91 | 39.59 | 0.00 | DATACENTER_TOP_ZN_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.00 | 1.00 | 0.00 | 4 | ||
211 | DATACENTER_TOP_ZN_6_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 36.20 | 36.20 | 36.20 | 180.00 | 0.00 | 0.91 | 39.59 | 0.00 | iz-DATACENTER_TOP_ZN_6_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
212 | DATACENTER_BASEMENT_ZN_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | DATACENTER_BASEMENT_ZN_6_WALL_NORTH_CFACTOR | 0.354 | 0.336 | 39.22 | 39.22 | 39.22 | 0.00 | 90.00 | 16.08 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
213 | DATACENTER_BASEMENT_ZN_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | DATACENTER_BASEMENT_ZN_6_WALL_SOUTH_CFACTOR | 0.354 | 0.336 | 39.22 | 39.22 | 39.22 | 180.00 | 90.00 | 16.08 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
214 | DATACENTER_BASEMENT_ZN_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | DATACENTER_BASEMENT_ZN_6_WALL_WEST_CFACTOR | 0.354 | 0.336 | 118.87 | 118.87 | 118.87 | 270.00 | 90.00 | 48.74 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
215 | DATACENTER_BASEMENT_ZN_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.87 | 118.87 | 118.87 | 90.00 | 90.00 | 48.74 | 2.44 | 0.00 | BASEMENT_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 0.50 | 0.50 | 4 | ||
216 | DATACENTER_BASEMENT_ZN_6_FLOOR | Floor | CTF - ConductionTransferFunction | EXT_SLAB_8IN_WITH_CARPET | 3.285 | 1.827 | 783.68 | 783.68 | 783.68 | 0.00 | 180.00 | 16.08 | 48.74 | 0.00 | DATACENTER_BASEMENT_ZN_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.00 | 1.00 | 0.00 | 4 | ||
217 | DATACENTER_BOT_ZN_6_FLOOR-PPAUTOCREATEOTHER | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 36.20 | 36.20 | 36.20 | 180.00 | 0.00 | 0.91 | 39.59 | 0.00 | DATACENTER_BOT_ZN_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
218 | DATACENTER_BASEMENT_ZN_6_CEILING-CORE_BOT_ZN_5 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 419.35 | 419.35 | 419.35 | 180.00 | 0.00 | 10.59 | 39.59 | 0.00 | DATACENTER_BASEMENT_ZN_6_CEILING-CORE_BOT_ZN_5-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
219 | PERIMETER_BOT_ZN_4_FLOOR-PPAUTOCREATEOTHER | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 201.98 | 201.98 | 201.98 | 135.00 | 0.00 | 6.47 | 48.74 | 0.00 | PERIMETER_BOT_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
220 | DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_1 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 63.08 | 63.08 | 63.08 | 180.00 | 0.00 | 16.08 | 6.47 | 0.00 | DATACENTER_BASEMENT_ZN_6-PERIMETER_BOT_ZN_1-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
221 | DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_3 | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 63.07 | 63.07 | 63.07 | 180.00 | 0.00 | 11.51 | 6.47 | 0.00 | DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_3-PPAUTOCREATEOTHER | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1Environment:Special Days |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | BASEMENT | RunPeriod: RUNPERIOD 1 | 1.9182494591E-003 | 1.3832776816E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
2 | CORE_BOTTOM | RunPeriod: RUNPERIOD 1 | 0.1056664777 | 8.4733176496E-002 | Pass | Pass | 0.2466043417 | 0.4294073712 | Pass | Pass |
3 | CORE_MID | RunPeriod: RUNPERIOD 1 | 1.4211383042E-002 | 1.0242356650E-002 | Pass | Pass | 0.4879254633 | 0.4870893550 | Pass | Pass |
4 | CORE_TOP | RunPeriod: RUNPERIOD 1 | 0.1582029468 | 0.1648987218 | Pass | Pass | 0.5778311199 | 0.5438859367 | Pass | Pass |
5 | PERIMETER_BOT_ZN_3 | RunPeriod: RUNPERIOD 1 | 0.1339401487 | 0.1573036182 | Pass | Pass | 1292.5726277879 | 15448.9656217083 | Pass | Pass |
6 | PERIMETER_BOT_ZN_2 | RunPeriod: RUNPERIOD 1 | 0.1422031830 | 0.1653963660 | Pass | Pass | 0.7952049160 | 5.0436104487 | Fail | Pass |
7 | PERIMETER_BOT_ZN_1 | RunPeriod: RUNPERIOD 1 | 0.1666456742 | 0.1760639651 | Pass | Pass | 0.6825460977 | 5.3289213263 | Pass | Fail |
8 | PERIMETER_BOT_ZN_4 | RunPeriod: RUNPERIOD 1 | 8.1840174461E-002 | 9.0077757475E-002 | Pass | Pass | 0.2562149047 | 0.4323903308 | Pass | Fail |
9 | PERIMETER_MID_ZN_3 | RunPeriod: RUNPERIOD 1 | 0.8935165616 | 0.7194195995 | Pass | Pass | 0.5836661991 | 0.5252060248 | Pass | Pass |
10 | PERIMETER_MID_ZN_2 | RunPeriod: RUNPERIOD 1 | 0.7863907059 | 0.7998411551 | Pass | Pass | 0.5522346892 | 0.5019604199 | Pass | Pass |
11 | PERIMETER_MID_ZN_1 | RunPeriod: RUNPERIOD 1 | 0.4972291636 | 0.5932686008 | Pass | Pass | 0.6407194111 | 0.8332803161 | Pass | Pass |
12 | PERIMETER_MID_ZN_4 | RunPeriod: RUNPERIOD 1 | 0.7350192034 | 0.7589870162 | Pass | Pass | 0.5577020869 | 0.5084243257 | Pass | Pass |
13 | PERIMETER_TOP_ZN_3 | RunPeriod: RUNPERIOD 1 | 1.1840747437 | 0.9550682692 | Pass | Pass | 0.5432789249 | 0.5064717547 | Pass | Pass |
14 | PERIMETER_TOP_ZN_2 | RunPeriod: RUNPERIOD 1 | 1.0796841332 | 1.0486366514 | Pass | Pass | 0.5468909764 | 0.4928070464 | Pass | Pass |
15 | PERIMETER_TOP_ZN_1 | RunPeriod: RUNPERIOD 1 | 0.7097323075 | 0.8505264507 | Pass | Pass | 0.6013349493 | 0.6340437673 | Pass | Pass |
16 | PERIMETER_TOP_ZN_4 | RunPeriod: RUNPERIOD 1 | 1.0388486551 | 1.0257665648 | Pass | Pass | 0.5496840218 | 0.4944400576 | Pass | Pass |
17 | GROUNDFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 3.7745900976E-002 | 4.5813483730E-002 | Pass | Pass | 0.2844808820 | 0.4653252081 | Fail | Pass |
18 | MIDFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 0.1285023273 | 8.3520609870E-002 | Pass | Pass | 0.4902592335 | 0.4906160302 | Pass | Pass |
19 | TOPFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 0.2801560818 | 0.2159676409 | Pass | Pass | 0.4913205395 | 0.4939068352 | Pass | Pass |
20 | DATACENTER_BOT_ZN_6 | RunPeriod: RUNPERIOD 1 | 1.6304031988E-002 | 1.5741354057E-002 | Pass | Pass | 0.1826814343 | 1.5043492597 | Pass | Fail |
21 | DATACENTER_MID_ZN_6 | RunPeriod: RUNPERIOD 1 | 2.7718699377E-002 | 3.8173942257E-002 | Pass | Pass | 8.9566611195E-003 | 1.5412620448E-002 | Pass | Pass |
22 | DATACENTER_TOP_ZN_6 | RunPeriod: RUNPERIOD 1 | 3.2442235997E-002 | 3.8690290890E-002 | Pass | Pass | 1.0667235582E-002 | 1.5805376319E-002 | Pass | Pass |
23 | DATACENTER_BASEMENT_ZN_6 | RunPeriod: RUNPERIOD 1 | 1.0576370592E-005 | 1.5190271373E-005 | Pass | Pass | 1.2508665043E-004 | 1.2035122716E-004 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Heat Emission by ComponentsEnvelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
Heat Emissions [GJ] | 6497.86 | 309.03 | 0.00 | 24424.82 | 18497.20 | 49728.90 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | -32.70 | 0.00 | -32.70 | Wetbulb [C] | 2.40 | 210.00 |
INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 30.10 | 12.40 | 21.10 | Wetbulb [C] | 4.70 | 200.00 |
Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
Jan | 0.00 | 0 | |||
Feb | 0.00 | 0 | |||
Mar | 12.00 | 13 | |||
Apr | 16.00 | 23 | |||
May | 0.00 | 0 | |||
Jun | 190.00 | 53 | |||
Jul | 136.00 | 41 | |||
Aug | 87.00 | 42 | |||
Sep | 0.00 | 0 | |||
Oct | 0.00 | 0 | |||
Nov | 0.00 | 0 | |||
Dec | 0.00 | 0 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
BASEMENT_WALL_EAST | BASEMENT_WALL_EAST_CFACTOR | 1.00 | 0.340 | 0.354 | 118.87 | 118.87 | 90.00 | 90.00 | E |
BASEMENT_WALL_SOUTH | BASEMENT_WALL_SOUTH_CFACTOR | 1.00 | 0.340 | 0.354 | 139.09 | 139.09 | 180.00 | 90.00 | S |
BASEMENT_WALL_NORTH | BASEMENT_WALL_NORTH_CFACTOR | 1.00 | 0.340 | 0.354 | 139.09 | 139.09 | 0.00 | 90.00 | N |
PERIMETER_BOT_ZN_3_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.928 | 1.078 | 200.61 | 105.88 | 0.00 | 90.00 | N |
PERIMETER_BOT_ZN_2_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.928 | 1.078 | 133.74 | 71.89 | 90.00 | 90.00 | E |
PERIMETER_BOT_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.928 | 1.078 | 200.61 | 105.88 | 180.00 | 90.00 | S |
PERIMETER_BOT_ZN_4_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.928 | 1.078 | 133.74 | 71.89 | 270.00 | 90.00 | W |
PERIMETER_MID_ZN_3_WALL_NORTH | NONRES_EXT_WALL_MID | 0.30 | 0.873 | 1.004 | 2006.06 | 1136.85 | 0.00 | 90.00 | N |
PERIMETER_MID_ZN_2_WALL_EAST | NONRES_EXT_WALL_MID | 0.30 | 0.873 | 1.004 | 1337.37 | 757.90 | 90.00 | 90.00 | E |
PERIMETER_MID_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 0.873 | 1.004 | 2006.06 | 1136.85 | 180.00 | 90.00 | S |
PERIMETER_MID_ZN_4_WALL_WEST | NONRES_EXT_WALL_MID | 0.30 | 0.873 | 1.004 | 1337.37 | 757.90 | 270.00 | 90.00 | W |
PERIMETER_TOP_ZN_3_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.164 | 1.410 | 200.61 | 113.68 | 0.00 | 90.00 | N |
PERIMETER_TOP_ZN_2_WALL_EAST | NONRES_EXT_WALL_TOP | 0.30 | 1.164 | 1.410 | 133.74 | 75.79 | 90.00 | 90.00 | E |
PERIMETER_TOP_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 1.164 | 1.410 | 200.61 | 113.68 | 180.00 | 90.00 | S |
PERIMETER_TOP_ZN_4_WALL_WEST | NONRES_EXT_WALL_TOP | 0.30 | 1.164 | 1.410 | 133.74 | 75.79 | 270.00 | 90.00 | W |
GROUNDFLOOR_PLENUM_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.928 | 1.078 | 89.13 | 89.13 | 0.00 | 90.00 | N |
GROUNDFLOOR_PLENUM_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.928 | 1.078 | 59.42 | 59.42 | 270.00 | 90.00 | W |
GROUNDFLOOR_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.928 | 1.078 | 89.13 | 89.13 | 180.00 | 90.00 | S |
GROUNDFLOOR_PLENUM_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.928 | 1.078 | 59.42 | 59.42 | 90.00 | 90.00 | E |
MIDFLOOR_PLENUM_WALL_NORTH | NONRES_EXT_WALL_MID | 0.30 | 0.873 | 1.004 | 891.32 | 891.32 | 0.00 | 90.00 | N |
MIDFLOOR_PLENUM_WALL_WEST | NONRES_EXT_WALL_MID | 0.30 | 0.873 | 1.004 | 594.21 | 594.21 | 270.00 | 90.00 | W |
MIDFLOOR_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 0.873 | 1.004 | 891.32 | 891.32 | 180.00 | 90.00 | S |
MIDFLOOR_PLENUM_WALL_EAST | NONRES_EXT_WALL_MID | 0.30 | 0.873 | 1.004 | 594.21 | 594.21 | 90.00 | 90.00 | E |
TOPFLOOR_PLENUM_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.164 | 1.410 | 89.13 | 89.13 | 180.00 | 90.00 | S |
TOPFLOOR_PLENUM_WALL_EAST | NONRES_EXT_WALL_TOP | 0.30 | 1.164 | 1.410 | 59.42 | 59.42 | 90.00 | 90.00 | E |
TOPFLOOR_PLENUM_WALL_WEST | NONRES_EXT_WALL_TOP | 0.30 | 1.164 | 1.410 | 59.42 | 59.42 | 270.00 | 90.00 | W |
TOPFLOOR_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 1.164 | 1.410 | 89.13 | 89.13 | 0.00 | 90.00 | N |
BUILDING_ROOF | NONRES_ROOF | 0.30 | 0.159 | 0.163 | 3563.11 | 3563.11 | 180.00 | 0.00 | |
DATACENTER_BASEMENT_ZN_6_WALL_NORTH | DATACENTER_BASEMENT_ZN_6_WALL_NORTH_CFACTOR | 1.00 | 0.340 | 0.354 | 39.22 | 39.22 | 0.00 | 90.00 | N |
DATACENTER_BASEMENT_ZN_6_WALL_SOUTH | DATACENTER_BASEMENT_ZN_6_WALL_SOUTH_CFACTOR | 1.00 | 0.340 | 0.354 | 39.22 | 39.22 | 180.00 | 90.00 | S |
DATACENTER_BASEMENT_ZN_6_WALL_WEST | DATACENTER_BASEMENT_ZN_6_WALL_WEST_CFACTOR | 1.00 | 0.340 | 0.354 | 118.87 | 118.87 | 270.00 | 90.00 | W |
Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
BASEMENT_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 118.87 | 118.87 | 270.00 | 90.00 | W |
BASEMENT_FLOOR | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 2779.43 | 2779.43 | 0.00 | 180.00 | |
PERIMETER_BOT_ZN_2_FLOOR-PPAUTOCREATEOTHER | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 201.98 | 201.98 | 225.00 | 0.00 | |
PERIMETER_BOT_ZN_1_FLOOR-PPAUTOCREATEOTHER | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 250.34 | 250.34 | 180.00 | 0.00 | |
CORE_BOT_ZN_5_FLOOR-PPAUTOCREATEOTHER | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 2076.77 | 2076.77 | 180.00 | 0.00 | |
PERIMETER_BOT_ZN_3_FLOOR-PPAUTOCREATEOTHER | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 250.34 | 250.34 | 180.00 | 0.00 | |
CORE_BOT_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 173.00 | 173.00 | 180.00 | 90.00 | S |
CORE_BOT_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 108.64 | 108.64 | 270.00 | 90.00 | W |
CORE_BOT_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 173.00 | 173.00 | 0.00 | 90.00 | N |
CORE_BOT_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 108.64 | 108.64 | 90.00 | 90.00 | E |
DATACENTER_BASEMENT_ZN_6_CEILING-CORE_BOT_ZN_5-PPAUTOCREATEOTHER | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 419.30 | 419.30 | 0.00 | 180.00 | |
CORE_BOT_ZN_5_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 2076.82 | 2076.82 | 0.00 | 180.00 | |
CORE_BOT_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 2496.12 | 2496.12 | 180.00 | 0.00 | |
CORE_MID_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 1729.99 | 1729.99 | 180.00 | 90.00 | S |
CORE_MID_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 1086.40 | 1086.40 | 270.00 | 90.00 | W |
CORE_MID_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 1729.99 | 1729.99 | 0.00 | 90.00 | N |
CORE_MID_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 1086.40 | 1086.40 | 90.00 | 90.00 | E |
CORE_MID_ZN_5_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.711 | 3.839 | 24961.20 | 24961.20 | 0.00 | 180.00 | |
CORE_MID_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 24961.20 | 24961.20 | 180.00 | 0.00 | |
CORE_TOP_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 173.00 | 173.00 | 180.00 | 90.00 | S |
CORE_TOP_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 108.64 | 108.64 | 270.00 | 90.00 | W |
CORE_TOP_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 173.00 | 173.00 | 0.00 | 90.00 | N |
CORE_TOP_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 108.64 | 108.64 | 90.00 | 90.00 | E |
CORE_TOP_ZN_5_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.711 | 3.839 | 2496.12 | 2496.12 | 0.00 | 180.00 | |
CORE_TOP_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 2496.12 | 2496.12 | 180.00 | 0.00 | |
PERIMETER_BOT_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.75 | 17.75 | 225.00 | 90.00 | W |
CORE_BOT_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 173.00 | 173.00 | 180.00 | 90.00 | S |
PERIMETER_BOT_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 17.75 | 17.75 | 135.00 | 90.00 | S |
DATACENTER_BOT_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 2.51 | 2.51 | 180.00 | 90.00 | S |
PERIMETER_BOT_ZN_3_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 250.34 | 250.34 | 0.00 | 180.00 | |
DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_3-PPAUTOCREATEOTHER | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 63.07 | 63.07 | 0.00 | 180.00 | |
PERIMETER_BOT_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 313.41 | 313.41 | 180.00 | 0.00 | |
PERIMETER_BOT_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.75 | 17.75 | 315.00 | 90.00 | N |
CORE_BOT_ZN_5_WALL_EAST-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 108.64 | 108.64 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_1_WALL_EAST-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 17.75 | 17.75 | 225.00 | 90.00 | W |
PERIMETER_BOT_ZN_2_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 201.98 | 201.98 | 45.00 | 180.00 | |
PERIMETER_BOT_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 201.98 | 201.98 | 225.00 | 0.00 | |
PERIMETER_BOT_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.75 | 17.75 | 45.00 | 90.00 | E |
DATACENTER_BOT_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 2.51 | 2.51 | 0.00 | 90.00 | N |
PERIMETER_BOT_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 17.75 | 17.75 | 315.00 | 90.00 | N |
CORE_BOT_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 173.00 | 173.00 | 0.00 | 90.00 | N |
DATACENTER_BASEMENT_ZN_6-PERIMETER_BOT_ZN_1-PPAUTOCREATEOTHER | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 63.07 | 63.07 | 0.00 | 180.00 | |
PERIMETER_BOT_ZN_1_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 250.35 | 250.35 | 0.00 | 180.00 | |
PERIMETER_BOT_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 313.42 | 313.42 | 180.00 | 0.00 | |
PERIMETER_BOT_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.75 | 17.75 | 135.00 | 90.00 | S |
DATACENTER_BOT_ZN_6_WALL_WEST-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 108.64 | 108.64 | 90.00 | 90.00 | E |
PERIMETER_BOT_ZN_3_WALL_WEST-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 17.75 | 17.75 | 45.00 | 90.00 | E |
PERIMETER_BOT_ZN_4_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 201.98 | 201.98 | 315.00 | 180.00 | |
PERIMETER_BOT_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 201.98 | 201.98 | 135.00 | 0.00 | |
PERIMETER_MID_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 177.47 | 177.47 | 225.00 | 90.00 | W |
CORE_MID_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 1729.99 | 1729.99 | 180.00 | 90.00 | S |
PERIMETER_MID_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 177.47 | 177.47 | 135.00 | 90.00 | S |
DATACENTER_MID_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 25.09 | 25.09 | 180.00 | 90.00 | S |
PERIMETER_MID_ZN_3_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.711 | 3.839 | 3134.13 | 3134.13 | 0.00 | 180.00 | |
PERIMETER_MID_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 3134.13 | 3134.13 | 180.00 | 0.00 | |
PERIMETER_MID_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 177.47 | 177.47 | 315.00 | 90.00 | N |
CORE_MID_ZN_5_WALL_EAST-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 1086.40 | 1086.40 | 270.00 | 90.00 | W |
PERIMETER_MID_ZN_1_WALL_EAST-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 177.47 | 177.47 | 225.00 | 90.00 | W |
PERIMETER_MID_ZN_2_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.711 | 3.839 | 2019.75 | 2019.75 | 45.00 | 180.00 | |
PERIMETER_MID_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 2019.75 | 2019.75 | 225.00 | 0.00 | |
PERIMETER_MID_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 177.47 | 177.47 | 45.00 | 90.00 | E |
DATACENTER_MID_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 25.09 | 25.09 | 0.00 | 90.00 | N |
PERIMETER_MID_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 177.47 | 177.47 | 315.00 | 90.00 | N |
CORE_MID_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 1729.99 | 1729.99 | 0.00 | 90.00 | N |
PERIMETER_MID_ZN_1_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.711 | 3.839 | 3134.20 | 3134.20 | 0.00 | 180.00 | |
PERIMETER_MID_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 3134.20 | 3134.20 | 180.00 | 0.00 | |
PERIMETER_MID_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 177.47 | 177.47 | 135.00 | 90.00 | S |
DATACENTER_MID_ZN_6_WALL_WEST-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 1086.40 | 1086.40 | 90.00 | 90.00 | E |
PERIMETER_MID_ZN_3_WALL_WEST-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 177.47 | 177.47 | 45.00 | 90.00 | E |
PERIMETER_MID_ZN_4_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.711 | 3.839 | 2019.75 | 2019.75 | 315.00 | 180.00 | |
PERIMETER_MID_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 2019.75 | 2019.75 | 135.00 | 0.00 | |
PERIMETER_TOP_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.75 | 17.75 | 225.00 | 90.00 | W |
CORE_TOP_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 173.00 | 173.00 | 180.00 | 90.00 | S |
PERIMETER_TOP_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 17.75 | 17.75 | 135.00 | 90.00 | S |
DATACENTER_TOP_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 2.51 | 2.51 | 180.00 | 90.00 | S |
PERIMETER_TOP_ZN_3_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.711 | 3.839 | 313.41 | 313.41 | 0.00 | 180.00 | |
PERIMETER_TOP_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 313.41 | 313.41 | 180.00 | 0.00 | |
PERIMETER_TOP_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.75 | 17.75 | 315.00 | 90.00 | N |
CORE_TOP_ZN_5_WALL_EAST-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 108.64 | 108.64 | 270.00 | 90.00 | W |
INT-PER3S-NE-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 17.75 | 17.75 | 225.00 | 90.00 | W |
PERIMETER_TOP_ZN_2_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.711 | 3.839 | 201.98 | 201.98 | 45.00 | 180.00 | |
PERIMETER_TOP_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 201.98 | 201.98 | 225.00 | 0.00 | |
INT-PER3S-NE | INT_WALL | 0.30 | 2.511 | 6.299 | 17.75 | 17.75 | 45.00 | 90.00 | E |
DATACENTER_TOP_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 2.51 | 2.51 | 0.00 | 90.00 | N |
PERIMETER_TOP_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 17.75 | 17.75 | 315.00 | 90.00 | N |
CORE_TOP_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 173.00 | 173.00 | 0.00 | 90.00 | N |
PERIMETER_TOP_ZN_1_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.711 | 3.839 | 313.42 | 313.42 | 0.00 | 180.00 | |
PERIMETER_TOP_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 313.42 | 313.42 | 180.00 | 0.00 | |
PERIMETER_TOP_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.75 | 17.75 | 135.00 | 90.00 | S |
DATACENTER_TOP_ZN_6_WALL_WEST-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 108.64 | 108.64 | 90.00 | 90.00 | E |
PERIMETER_TOP_ZN_3_WALL_WEST-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 17.75 | 17.75 | 45.00 | 90.00 | E |
PERIMETER_TOP_ZN_4_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.711 | 3.839 | 201.98 | 201.98 | 315.00 | 180.00 | |
PERIMETER_TOP_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 201.98 | 201.98 | 135.00 | 0.00 | |
iz-CORE_BOT_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 2496.12 | 2496.12 | 0.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 313.41 | 313.41 | 0.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 201.98 | 201.98 | 45.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 313.42 | 313.42 | 0.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 201.98 | 201.98 | 315.00 | 180.00 | |
iz-DATACENTER_BOT_ZN_6_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 36.20 | 36.20 | 0.00 | 180.00 | |
GROUNDFLOOR_PLENUM_CEILING | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 3563.11 | 3563.11 | 180.00 | 0.00 | |
iz-CORE_MID_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 24961.20 | 24961.20 | 0.00 | 180.00 | |
iz-PERIMETER_MID_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 3134.13 | 3134.13 | 0.00 | 180.00 | |
iz-PERIMETER_MID_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 2019.75 | 2019.75 | 45.00 | 180.00 | |
iz-PERIMETER_MID_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 3134.20 | 3134.20 | 0.00 | 180.00 | |
iz-PERIMETER_MID_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 2019.75 | 2019.75 | 315.00 | 180.00 | |
iz-DATACENTER_MID_ZN_6_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 362.03 | 362.03 | 0.00 | 180.00 | |
MIDFLOOR_PLENUM_CEILING | INT_SLAB_CEILING | 0.30 | 2.104 | 3.839 | 35631.06 | 35631.06 | 180.00 | 0.00 | |
iz-CORE_TOP_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 2496.12 | 2496.12 | 0.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 313.41 | 313.41 | 0.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 201.98 | 201.98 | 45.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 313.42 | 313.42 | 0.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 201.98 | 201.98 | 315.00 | 180.00 | |
iz-DATACENTER_TOP_ZN_6_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 36.20 | 36.20 | 0.00 | 180.00 | |
DATACENTER_BOT_ZN_6_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 2.51 | 2.51 | 0.00 | 90.00 | N |
DATACENTER_BOT_ZN_6_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 2.51 | 2.51 | 180.00 | 90.00 | S |
DATACENTER_BOT_ZN_6_WALL_EAST-PPAUTOCREATEOTHER | INT_WALL | 0.30 | 2.511 | 6.299 | 108.64 | 108.64 | 90.00 | 90.00 | E |
DATACENTER_BOT_ZN_6_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 108.64 | 108.64 | 270.00 | 90.00 | W |
DATACENTER_BOT_ZN_6_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 36.20 | 36.20 | 0.00 | 180.00 | |
DATACENTER_BOT_ZN_6_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 36.20 | 36.20 | 180.00 | 0.00 | |
DATACENTER_MID_ZN_6_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 1086.40 | 1086.40 | 270.00 | 90.00 | W |
DATACENTER_MID_ZN_6_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 25.09 | 25.09 | 180.00 | 90.00 | S |
DATACENTER_MID_ZN_6_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 1086.40 | 1086.40 | 90.00 | 90.00 | E |
DATACENTER_MID_ZN_6_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 25.09 | 25.09 | 0.00 | 90.00 | N |
DATACENTER_MID_ZN_6_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.711 | 3.839 | 362.03 | 362.03 | 0.00 | 180.00 | |
DATACENTER_MID_ZN_6_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 362.03 | 362.03 | 180.00 | 0.00 | |
DATACENTER_TOP_ZN_6_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 108.64 | 108.64 | 90.00 | 90.00 | E |
DATACENTER_TOP_ZN_6_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 108.64 | 108.64 | 270.00 | 90.00 | W |
DATACENTER_TOP_ZN_6_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 2.51 | 2.51 | 180.00 | 90.00 | S |
DATACENTER_TOP_ZN_6_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 2.51 | 2.51 | 0.00 | 90.00 | N |
DATACENTER_TOP_ZN_6_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.711 | 3.839 | 36.20 | 36.20 | 0.00 | 180.00 | |
DATACENTER_TOP_ZN_6_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 36.20 | 36.20 | 180.00 | 0.00 | |
DATACENTER_BASEMENT_ZN_6_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 118.87 | 118.87 | 90.00 | 90.00 | E |
DATACENTER_BASEMENT_ZN_6_FLOOR | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.591 | 3.285 | 783.68 | 783.68 | 0.00 | 180.00 | |
DATACENTER_BOT_ZN_6_FLOOR-PPAUTOCREATEOTHER | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 36.20 | 36.20 | 180.00 | 0.00 | |
DATACENTER_BASEMENT_ZN_6_CEILING-CORE_BOT_ZN_5 | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 419.35 | 419.35 | 180.00 | 0.00 | |
PERIMETER_BOT_ZN_4_FLOOR-PPAUTOCREATEOTHER | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 201.98 | 201.98 | 135.00 | 0.00 | |
DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_1 | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 63.08 | 63.08 | 180.00 | 0.00 | |
DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_3 | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 63.07 | 63.07 | 180.00 | 0.00 | |
BASEMENT_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 7126.21 | 0.00 | 90.00 | N | ||
CORE_BOTTOM_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 5064.65 | 0.00 | 90.00 | N | ||
CORE_MID_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 50646.53 | 0.00 | 90.00 | N | ||
CORE_TOP_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 5064.65 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 626.83 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 403.95 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 626.84 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 403.95 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 6268.26 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 4039.50 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 6268.35 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 4039.48 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 626.83 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 403.95 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 626.84 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 403.95 | 0.00 | 90.00 | N |
Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | WINDOW_U_0.2925_SHGC_NORTH_0.45 | 17.38 | 0.00 | 0.00 | 17.38 | 17.38 | 1.661 | 0.451 | 0.452 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | WINDOW_U_0.2925_SHGC_NORTH_0.45 | 17.38 | 0.00 | 0.00 | 17.38 | 17.38 | 1.661 | 0.451 | 0.452 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | WINDOW_U_0.2925_SHGC_NORTH_0.45 | 17.38 | 0.00 | 0.00 | 17.38 | 17.38 | 1.661 | 0.451 | 0.452 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | WINDOW_U_0.2925_SHGC_NORTH_0.45 | 17.38 | 0.00 | 0.00 | 17.38 | 17.38 | 1.661 | 0.451 | 0.452 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | WINDOW_U_0.2925_SHGC_NORTH_0.45 | 17.38 | 0.00 | 0.00 | 17.38 | 17.38 | 1.661 | 0.451 | 0.452 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | WINDOW_U_0.2925_SHGC_EAST_0.45 | 19.32 | 0.00 | 0.00 | 19.32 | 19.32 | 1.661 | 0.451 | 0.452 | No | PERIMETER_BOT_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | WINDOW_U_0.2925_SHGC_EAST_0.45 | 19.32 | 0.00 | 0.00 | 19.32 | 19.32 | 1.661 | 0.451 | 0.452 | No | PERIMETER_BOT_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | WINDOW_U_0.2925_SHGC_EAST_0.45 | 19.32 | 0.00 | 0.00 | 19.32 | 19.32 | 1.661 | 0.451 | 0.452 | No | PERIMETER_BOT_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | WINDOW_U_0.2925_SHGC_SOUTH_0.45 | 17.38 | 0.00 | 0.00 | 17.38 | 17.38 | 1.661 | 0.451 | 0.452 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | WINDOW_U_0.2925_SHGC_SOUTH_0.45 | 17.38 | 0.00 | 0.00 | 17.38 | 17.38 | 1.661 | 0.451 | 0.452 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | WINDOW_U_0.2925_SHGC_SOUTH_0.45 | 17.38 | 0.00 | 0.00 | 17.38 | 17.38 | 1.661 | 0.451 | 0.452 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | WINDOW_U_0.2925_SHGC_SOUTH_0.45 | 17.38 | 0.00 | 0.00 | 17.38 | 17.38 | 1.661 | 0.451 | 0.452 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | WINDOW_U_0.2925_SHGC_SOUTH_0.45 | 17.38 | 0.00 | 0.00 | 17.38 | 17.38 | 1.661 | 0.451 | 0.452 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | WINDOW_U_0.2925_SHGC_WEST_0.45 | 19.32 | 0.00 | 0.00 | 19.32 | 19.32 | 1.661 | 0.451 | 0.452 | No | PERIMETER_BOT_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | WINDOW_U_0.2925_SHGC_WEST_0.45 | 19.32 | 0.00 | 0.00 | 19.32 | 19.32 | 1.661 | 0.451 | 0.452 | No | PERIMETER_BOT_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | WINDOW_U_0.2925_SHGC_WEST_0.45 | 19.32 | 0.00 | 0.00 | 19.32 | 19.32 | 1.661 | 0.451 | 0.452 | No | PERIMETER_BOT_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | WINDOW_U_0.2925_SHGC_NORTH_0.45 | 86.92 | 0.00 | 0.00 | 86.92 | 869.21 | 1.661 | 0.451 | 0.452 | No | PERIMETER_MID_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | WINDOW_U_0.2925_SHGC_EAST_0.45 | 57.95 | 0.00 | 0.00 | 57.95 | 579.48 | 1.661 | 0.451 | 0.452 | No | PERIMETER_MID_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | WINDOW_U_0.2925_SHGC_SOUTH_0.45 | 86.92 | 0.00 | 0.00 | 86.92 | 869.21 | 1.661 | 0.451 | 0.452 | No | PERIMETER_MID_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | WINDOW_U_0.2925_SHGC_WEST_0.45 | 57.95 | 0.00 | 0.00 | 57.95 | 579.48 | 1.661 | 0.451 | 0.452 | No | PERIMETER_MID_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | WINDOW_U_0.2925_SHGC_NORTH_0.45 | 86.92 | 0.00 | 0.00 | 86.92 | 86.92 | 1.661 | 0.451 | 0.452 | No | PERIMETER_TOP_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | WINDOW_U_0.2925_SHGC_EAST_0.45 | 57.95 | 0.00 | 0.00 | 57.95 | 57.95 | 1.661 | 0.451 | 0.452 | No | PERIMETER_TOP_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | WINDOW_U_0.2925_SHGC_SOUTH_0.45 | 86.92 | 0.00 | 0.00 | 86.92 | 86.92 | 1.661 | 0.451 | 0.452 | No | PERIMETER_TOP_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | WINDOW_U_0.2925_SHGC_WEST_0.45 | 57.95 | 0.00 | 0.00 | 57.95 | 57.95 | 1.661 | 0.451 | 0.452 | No | PERIMETER_TOP_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
Total or Average | 3476.85 | 1.661 | 0.451 | 0.452 | |||||||||||||||||
North Total or Average | 1043.06 | 1.661 | 0.451 | 0.452 | |||||||||||||||||
Non-North Total or Average | 2433.80 | 1.661 | 0.451 | 0.452 |
Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
None |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_3_WALL_NORTH |
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_3_WALL_NORTH |
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR3 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_3_WALL_NORTH |
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR4 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_3_WALL_NORTH |
PERIMETER_BOT_ZN_2_WALL_EAST_DOOR1 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_2_WALL_EAST |
PERIMETER_BOT_ZN_2_WALL_EAST_DOOR2 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_2_WALL_EAST |
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_1_WALL_SOUTH |
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_1_WALL_SOUTH |
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR3 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_1_WALL_SOUTH |
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR4 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_1_WALL_SOUTH |
PERIMETER_BOT_ZN_4_WALL_WEST_DOOR1 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_4_WALL_WEST |
PERIMETER_BOT_ZN_4_WALL_WEST_DOOR2 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_4_WALL_WEST |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Interior LightingZone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
BASEMENT_LIGHTS | BASEMENT | BASEMENT | GENERAL | 9.3279 | 2779.43 | 25926.33 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 49.41 | 0.0000 | Y | 240.45 |
CORE_BOTTOM_LIGHTS | CORE_BOTTOM | CORE_BOTTOM | GENERAL | 9.3279 | 2496.12 | 23283.67 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 49.41 | 0.0000 | Y | 215.94 |
CORE_MID_LIGHTS | CORE_MID | CORE_MID | GENERAL | 9.3279 | 24961.20 | 232836.67 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 49.41 | 0.0000 | Y | 2159.39 |
CORE_TOP_LIGHTS | CORE_TOP | CORE_TOP | GENERAL | 9.3279 | 2496.12 | 23283.67 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 49.41 | 0.0000 | Y | 215.94 |
PERIMETER_BOT_ZN_3_LIGHTS | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3 | GENERAL | 9.3279 | 313.41 | 2923.50 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 34.22 | 0.0000 | Y | 18.78 |
PERIMETER_BOT_ZN_2_LIGHTS | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2 | GENERAL | 9.3279 | 201.98 | 1884.01 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 34.13 | 0.0000 | Y | 12.07 |
PERIMETER_BOT_ZN_1_LIGHTS | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1 | GENERAL | 9.3279 | 313.42 | 2923.56 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 33.97 | 0.0000 | Y | 18.64 |
PERIMETER_BOT_ZN_4_LIGHTS | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4 | GENERAL | 9.3279 | 201.98 | 1884.01 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 34.08 | 0.0000 | Y | 12.05 |
PERIMETER_MID_ZN_3_LIGHTS | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3 | GENERAL | 9.3279 | 3134.13 | 29234.97 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 34.26 | 0.0000 | Y | 187.99 |
PERIMETER_MID_ZN_2_LIGHTS | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2 | GENERAL | 9.3279 | 2019.75 | 18840.12 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 34.14 | 0.0000 | Y | 120.76 |
PERIMETER_MID_ZN_1_LIGHTS | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1 | GENERAL | 9.3279 | 3134.20 | 29235.61 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 33.99 | 0.0000 | Y | 186.55 |
PERIMETER_MID_ZN_4_LIGHTS | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4 | GENERAL | 9.3279 | 2019.75 | 18840.12 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 34.09 | 0.0000 | Y | 120.55 |
PERIMETER_TOP_ZN_3_LIGHTS | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3 | GENERAL | 9.3279 | 313.41 | 2923.50 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 34.26 | 0.0000 | Y | 18.80 |
PERIMETER_TOP_ZN_2_LIGHTS | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2 | GENERAL | 9.3279 | 201.98 | 1884.01 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 34.14 | 0.0000 | Y | 12.08 |
PERIMETER_TOP_ZN_1_LIGHTS | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1 | GENERAL | 9.3279 | 313.42 | 2923.56 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 33.99 | 0.0000 | Y | 18.65 |
PERIMETER_TOP_ZN_4_LIGHTS | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4 | GENERAL | 9.3279 | 201.98 | 1884.01 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 34.09 | 0.0000 | Y | 12.06 |
DATACENTER_BASEMENT_LIGHTS | DATACENTER_BASEMENT_ZN_6 | DATACENTER_BASEMENT_ZN_6 | GENERAL | 9.3279 | 783.68 | 7310.12 | LightsWired | LTG_SCH_OFFICE | 50.72 | 168.00 | 49.41 | 0.0000 | Y | 67.80 |
DATACENTER_BOT_LIGHTS | DATACENTER_BOT_ZN_6 | DATACENTER_BOT_ZN_6 | GENERAL | 16.0861 | 36.20 | 582.36 | LightsWired | LTG_SCH_DATACENTER | 56.02 | 168.00 | 54.57 | 0.0000 | Y | 5.97 |
DATACENTER_MID_LIGHTS | DATACENTER_MID_ZN_6 | DATACENTER_MID_ZN_6 | GENERAL | 16.0861 | 362.03 | 5823.61 | LightsWired | LTG_SCH_DATACENTER | 56.02 | 168.00 | 54.57 | 0.0000 | Y | 59.65 |
DATACENTER_TOP_LIGHTS | DATACENTER_TOP_ZN_6 | DATACENTER_TOP_ZN_6 | GENERAL | 16.0861 | 36.20 | 582.36 | LightsWired | LTG_SCH_DATACENTER | 56.02 | 168.00 | 54.57 | 0.0000 | Y | 5.97 |
Interior Lighting Total | 9.3913 | 46320.38 | 435009.77 | 1158.67 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
PERIMETER_BOT_ZN_1_DAYLREFPT1 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.39 | 2923.56 | 1127.62 |
PERIMETER_BOT_ZN_1_DAYLREFPT2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 2923.56 | 0.00 |
PERIMETER_BOT_ZN_2_DAYLREFPT1 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.39 | 1884.01 | 726.66 |
PERIMETER_BOT_ZN_2_DAYLREFPT2 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 1884.01 | 0.00 |
PERIMETER_BOT_ZN_3_DAYLREFPT1 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.39 | 2923.50 | 1127.59 |
PERIMETER_BOT_ZN_3_DAYLREFPT2 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 2923.50 | 0.00 |
PERIMETER_BOT_ZN_4_DAYLREFPT1 | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.39 | 1884.01 | 726.66 |
PERIMETER_BOT_ZN_4_DAYLREFPT2 | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 1884.01 | 0.00 |
PERIMETER_MID_ZN_1_DAYLREFPT1 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.39 | 2923.56 | 1127.62 |
PERIMETER_MID_ZN_1_DAYLREFPT2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 2923.56 | 0.00 |
PERIMETER_MID_ZN_2_DAYLREFPT1 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.39 | 1884.01 | 726.66 |
PERIMETER_MID_ZN_2_DAYLREFPT2 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 1884.01 | 0.00 |
PERIMETER_MID_ZN_3_DAYLREFPT1 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.39 | 2923.50 | 1127.59 |
PERIMETER_MID_ZN_3_DAYLREFPT2 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 2923.50 | 0.00 |
PERIMETER_MID_ZN_4_DAYLREFPT1 | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.39 | 1884.01 | 726.66 |
PERIMETER_MID_ZN_4_DAYLREFPT2 | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 1884.01 | 0.00 |
PERIMETER_TOP_ZN_1_DAYLREFPT1 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.39 | 2923.56 | 1127.62 |
PERIMETER_TOP_ZN_1_DAYLREFPT2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 2923.56 | 0.00 |
PERIMETER_TOP_ZN_2_DAYLREFPT1 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.39 | 1884.01 | 726.66 |
PERIMETER_TOP_ZN_2_DAYLREFPT2 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 1884.01 | 0.00 |
PERIMETER_TOP_ZN_3_DAYLREFPT1 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.39 | 2923.50 | 1127.59 |
PERIMETER_TOP_ZN_3_DAYLREFPT2 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 2923.50 | 0.00 |
PERIMETER_TOP_ZN_4_DAYLREFPT1 | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.39 | 1884.01 | 726.66 |
PERIMETER_TOP_ZN_4_DAYLREFPT2 | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 1884.01 | 0.00 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 9973.01 | AstronomicalClock | - | 42.55 | 42.55 | 79.66 | |
EXTERIOR_LIGHTS_B | 44362.79 | AstronomicalClock | - | 83.52 | 71.23 | 593.15 | |
Exterior Lighting Total | 54335.80 | 672.82 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Central PlantType | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
BYPASS HEAT EXCHANGER | HeatExchanger:FluidToFluid | 2608319.40 | |||||
HEATSYS1 BOILER | Boiler:HotWater | 3732442.20 | 0.81 | ||||
COOLSYS1 CHILLER1 | Chiller:Electric:ReformulatedEIR | 1323676.83 | 6.28 | 1266935.78 | 5.98 | 6.84 | 23.33 |
COOLSYS1 CHILLER2 | Chiller:Electric:ReformulatedEIR | 1323676.83 | 6.28 | 1266935.78 | 5.98 | 6.84 | 23.33 |
CENTRAL TOWER | FluidCooler:TwoSpeed | 582060.00 | |||||
CENTRAL BOILER | Boiler:HotWater | 547194.34 | 0.80 | ||||
TOWERWATERSYS COOLTOWER 1 | CoolingTower:VariableSpeed | 1571052.59 | |||||
TOWERWATERSYS COOLTOWER 2 | CoolingTower:VariableSpeed | 1571052.59 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
VAV_BOT WITH REHEAT COOLING COIL | Coil:Cooling:Water | 215745.21 | 256563.43 | 172774.61 | 83788.82 | 0.67 | - | 27581.77 | 279.75 |
VAV_MID WITH REHEAT COOLING COIL | Coil:Cooling:Water | 2064211.47 | 2413123.81 | 1618216.42 | 794907.40 | 0.67 | - | 259548.48 | 2632.48 |
VAV_TOP WITH REHEAT COOLING COIL | Coil:Cooling:Water | 214361.48 | 254940.73 | 171670.93 | 83269.80 | 0.67 | - | 27416.21 | 278.07 |
CAV_BAS COOLING COIL | Coil:Cooling:Water | 120013.43 | 144606.59 | 98398.98 | 46207.61 | 0.68 | - | 15157.98 | 153.74 |
AIRLOOP DATACENTER BASEMENT COOLING COIL | Coil:Cooling:WaterToAirHeatPump:EquationFit | 436569.56 | 301670.86 | 134898.70 | 0.69 | 0.00 | |||
AIRLOOP DATACENTER BOT COOLING COIL | Coil:Cooling:WaterToAirHeatPump:EquationFit | 10097.06 | 7032.30 | 3064.77 | 0.70 | 0.00 | |||
AIRLOOP DATACENTER MID COOLING COIL | Coil:Cooling:WaterToAirHeatPump:EquationFit | 96893.41 | 67443.17 | 29450.24 | 0.70 | 0.00 | |||
AIRLOOP DATACENTER TOP COOLING COIL | Coil:Cooling:WaterToAirHeatPump:EquationFit | 9826.64 | 6840.10 | 2986.54 | 0.70 | 0.00 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
None |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
None |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | Coil:Heating:Water | 28719.18 | 27224.16 | - |
CORE_MID VAV BOX REHEAT COIL | Coil:Heating:Water | 546187.57 | 517332.81 | - |
CORE_TOP VAV BOX REHEAT COIL | Coil:Heating:Water | 115129.54 | 109097.81 | - |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Water | 19997.96 | 18948.52 | - |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Water | 13718.59 | 12998.53 | - |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 21947.42 | 20795.36 | - |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Water | 12469.38 | 11812.57 | - |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Water | 287082.78 | 272000.17 | - |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Water | 190404.41 | 180400.35 | - |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 290029.29 | 274791.54 | - |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Water | 186173.95 | 176392.54 | - |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Water | 38033.07 | 36033.82 | - |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Water | 25094.30 | 23775.13 | - |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 38414.88 | 36395.52 | - |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Water | 25000.02 | 23685.80 | - |
VAV_BOT WITH REHEAT HEATING COIL | Coil:Heating:Water | 129814.53 | 80429.27 | - |
VAV_MID WITH REHEAT HEATING COIL | Coil:Heating:Water | 1312673.62 | 789052.45 | - |
VAV_TOP WITH REHEAT HEATING COIL | Coil:Heating:Water | 131950.32 | 81101.63 | - |
CAV_BAS HEATING COIL | Coil:Heating:Water | 319601.40 | 237408.52 | - |
AIRLOOP DATACENTER BASEMENT HEATING COIL | Coil:Heating:WaterToAirHeatPump:EquationFit | 436569.56 | 0.00 | |
AIRLOOP DATACENTER BOT HEATING COIL | Coil:Heating:WaterToAirHeatPump:EquationFit | 10097.06 | 0.00 | |
AIRLOOP DATACENTER MID HEATING COIL | Coil:Heating:WaterToAirHeatPump:EquationFit | 96893.41 | 0.00 | |
AIRLOOP DATACENTER TOP HEATING COIL | Coil:Heating:WaterToAirHeatPump:EquationFit | 9826.64 | 0.00 | |
AIRLOOP DATACENTER BASEMENT_SUPPHEATCOIL | Coil:Heating:Electric | 28525.81 | 1.00 | |
AIRLOOP DATACENTER BOT_SUPPHEATCOIL | Coil:Heating:Electric | 1317.77 | 1.00 | |
AIRLOOP DATACENTER MID_SUPPHEATCOIL | Coil:Heating:Electric | 13177.74 | 1.00 | |
AIRLOOP DATACENTER TOP_SUPPHEATCOIL | Coil:Heating:Electric | 1317.77 | 1.00 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
VAV_BOT WITH REHEAT FAN | Fan:VariableVolume | 0.61 | 1389.42 | 10.11 | 22965.91 | 2271.59 | 1.00 | 1.12 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 |
VAV_MID WITH REHEAT FAN | Fan:VariableVolume | 0.61 | 1389.42 | 93.88 | 214393.15 | 2283.73 | 1.00 | 1.07 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 |
VAV_TOP WITH REHEAT FAN | Fan:VariableVolume | 0.61 | 1389.42 | 10.04 | 22814.90 | 2271.59 | 1.00 | 1.12 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 |
CAV_BAS FAN | Fan:ConstantVolume | 0.60 | 1018.41 | 5.91 | 10020.67 | 1695.65 | 1.00 | 1.15 | General | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
AIRLOOP DATACENTER BASEMENT SUPPLY FAN | Fan:OnOff | 0.62 | 1018.41 | 22.28 | 36748.76 | 1649.25 | 1.00 | 1.14 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 07:10:00 |
AIRLOOP DATACENTER BOT SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.52 | 587.43 | 1120.11 | 1.00 | 1.58 | General | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
AIRLOOP DATACENTER MID SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 5.03 | 5631.17 | 1120.11 | 1.00 | 1.15 | General | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
AIRLOOP DATACENTER TOP SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.51 | 571.11 | 1120.11 | 1.00 | 1.60 | General | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
COOLSYS1 PUMP SECONDARY | Pump:VariableSpeed | Intermittent | 133527.72 | 0.111220 | 22918.26 | 206062.94 | 0.90 | General |
HEATSYS1 PUMP | Pump:VariableSpeed | Intermittent | 180705.70 | 0.032653 | 9833.66 | 301156.09 | 0.90 | General |
COOLSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 92445.74 | 0.111220 | 15867.08 | 142664.32 | 0.90 | General |
PLANT CIRC PUMP | Pump:ConstantSpeed | Intermittent | 179045.11 | 0.013552 | 3456.54 | 255050.01 | 0.90 | General |
SWHSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 3168.45 | 0.000440 | 5.96 | 13540.37 | 0.30 | General |
TOWERWATERSYS PUMP | HeaderedPumps:VariableSpeed | Intermittent | 180718.98 | 0.131008 | 39456.67 | 301178.23 | 0.90 | General |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SWHSYS1 WATER HEATER | WaterHeater:Mixed | 1.14 | 87921.32 | 0.80 | 0.50 | 0.08 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BASEMENT | 78640.91 | 78640.91 | 28.29 | 5.910 | 5.910 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 24.00 | 24.00 | 0.00894 | 20.92 | 0.01271 | 1.200 | 0.00 |
CORE_BOTTOM | 82341.72 | 82341.72 | 32.99 | 6.187 | 6.187 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 24.00 | 24.00 | 0.00888 | 20.92 | 0.01271 | 1.078 | 0.00 |
CORE_MID | 773591.75 | 773591.75 | 309.92 | 58.113 | 58.113 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 24.00 | 24.00 | 0.00890 | 20.92 | 0.01271 | 10.778 | 0.00 |
CORE_TOP | 76074.11 | 76074.11 | 30.48 | 5.715 | 5.715 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 24.00 | 24.00 | 0.00891 | 20.92 | 0.01271 | 1.078 | 0.00 |
PERIMETER_BOT_ZN_3 | 12771.02 | 12771.02 | 40.75 | 0.968 | 0.968 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 24.00 | 24.00 | 0.00890 | 30.10 | 0.01273 | 0.135 | 0.00 |
PERIMETER_BOT_ZN_2 | 17016.24 | 17016.24 | 84.25 | 1.290 | 1.290 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 24.00 | 24.00 | 0.00870 | 21.71 | 0.01271 | 0.087 | 0.00 |
PERIMETER_BOT_ZN_1 | 21085.08 | 21085.08 | 67.27 | 1.599 | 1.599 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | 24.00 | 24.00 | 0.00875 | 29.69 | 0.01273 | 0.135 | 0.00 |
PERIMETER_BOT_ZN_4 | 20599.83 | 20599.83 | 101.99 | 1.562 | 1.562 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:10:00 | 24.00 | 24.00 | 0.00866 | 28.16 | 0.01272 | 0.087 | 0.00 |
PERIMETER_MID_ZN_3 | 118876.52 | 118876.52 | 379.30 | 9.014 | 9.014 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | 24.00 | 24.00 | 0.00907 | 30.10 | 0.01273 | 1.353 | 0.00 |
PERIMETER_MID_ZN_2 | 178643.54 | 178643.54 | 884.48 | 13.545 | 13.545 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 09:10:00 | 24.00 | 24.00 | 0.00876 | 23.63 | 0.01271 | 0.872 | 0.00 |
PERIMETER_MID_ZN_1 | 213332.82 | 213332.82 | 680.66 | 16.176 | 16.176 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 24.00 | 24.00 | 0.00883 | 29.79 | 0.01273 | 1.353 | 0.00 |
PERIMETER_MID_ZN_4 | 188187.70 | 188187.70 | 931.74 | 14.269 | 14.269 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:20:00 | 24.00 | 24.00 | 0.00875 | 27.95 | 0.01272 | 0.872 | 0.00 |
PERIMETER_TOP_ZN_3 | 13210.12 | 13210.12 | 42.15 | 1.002 | 1.002 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 24.00 | 24.00 | 0.00907 | 30.10 | 0.01273 | 0.135 | 0.00 |
PERIMETER_TOP_ZN_2 | 17850.27 | 17850.27 | 88.38 | 1.354 | 1.354 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 09:20:00 | 24.00 | 24.00 | 0.00879 | 23.98 | 0.01272 | 0.087 | 0.00 |
PERIMETER_TOP_ZN_1 | 22603.51 | 22603.51 | 72.12 | 1.714 | 1.714 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 24.00 | 24.00 | 0.00884 | 30.00 | 0.01273 | 0.135 | 0.00 |
PERIMETER_TOP_ZN_4 | 19743.83 | 19743.83 | 97.75 | 1.497 | 1.497 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:20:00 | 24.00 | 24.00 | 0.00876 | 27.95 | 0.01272 | 0.087 | 0.00 |
DATACENTER_BOT_ZN_6 | 8769.73 | 8769.73 | 242.24 | 0.524 | 0.524 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:20:00 | 27.00 | 27.00 | 0.00858 | 24.81 | 0.01272 | 0.016 | 0.00 |
DATACENTER_MID_ZN_6 | 84067.62 | 84067.62 | 2322.13 | 5.027 | 5.027 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:20:00 | 27.00 | 27.00 | 0.00859 | 24.81 | 0.01272 | 0.156 | 0.00 |
DATACENTER_TOP_ZN_6 | 8526.09 | 8526.09 | 235.51 | 0.510 | 0.510 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:10:00 | 27.00 | 27.00 | 0.00858 | 25.04 | 0.01272 | 0.016 | 0.00 |
DATACENTER_BASEMENT_ZN_6 | 372606.73 | 372606.73 | 475.46 | 22.282 | 22.282 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 07:00:00 | 27.00 | 27.00 | 0.00854 | 18.82 | 0.01271 | 0.338 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BASEMENT | 0.00 | 0.00 | 0.00 | 0.000 | 1.200 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 22.70 | 0.00018 | -32.70 | 0.00018 | 1.200 | 0.00 |
CORE_BOTTOM | 9854.57 | 9854.57 | 3.95 | 0.434 | 1.078 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00800 | -32.70 | 0.00018 | 1.078 | 0.00 |
CORE_MID | 361151.29 | 361151.29 | 144.69 | 15.950 | 15.950 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00800 | -32.70 | 0.00018 | 10.778 | 0.00 |
CORE_TOP | 80597.23 | 80597.23 | 32.29 | 3.579 | 3.579 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00800 | -32.70 | 0.00018 | 1.078 | 0.00 |
PERIMETER_BOT_ZN_3 | 13996.63 | 13996.63 | 44.66 | 0.622 | 0.622 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00776 | -32.70 | 0.00018 | 0.135 | 0.00 |
PERIMETER_BOT_ZN_2 | 9601.01 | 9601.01 | 47.54 | 0.427 | 0.427 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00778 | -32.70 | 0.00018 | 0.087 | 0.00 |
PERIMETER_BOT_ZN_1 | 15359.47 | 15359.47 | 49.01 | 0.683 | 0.683 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00779 | -32.70 | 0.00018 | 0.135 | 0.00 |
PERIMETER_BOT_ZN_4 | 7951.71 | 7951.71 | 39.37 | 0.353 | 0.353 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00768 | -32.70 | 0.00018 | 0.087 | 0.00 |
PERIMETER_MID_ZN_3 | 200892.77 | 200892.77 | 640.98 | 8.941 | 8.941 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00765 | -32.70 | 0.00018 | 1.353 | 0.00 |
PERIMETER_MID_ZN_2 | 133237.73 | 133237.73 | 659.67 | 5.930 | 5.930 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00765 | -32.70 | 0.00018 | 0.872 | 0.00 |
PERIMETER_MID_ZN_1 | 202952.83 | 202952.83 | 647.54 | 9.032 | 9.032 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00766 | -32.70 | 0.00018 | 1.353 | 0.00 |
PERIMETER_MID_ZN_4 | 130279.73 | 130279.73 | 645.03 | 5.798 | 5.798 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00764 | -32.70 | 0.00018 | 0.872 | 0.00 |
PERIMETER_TOP_ZN_3 | 26610.44 | 26610.44 | 84.91 | 1.185 | 1.185 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00767 | -32.70 | 0.00018 | 0.135 | 0.00 |
PERIMETER_TOP_ZN_2 | 17557.50 | 17557.50 | 86.93 | 0.782 | 0.782 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00767 | -32.70 | 0.00018 | 0.087 | 0.00 |
PERIMETER_TOP_ZN_1 | 26877.39 | 26877.39 | 85.76 | 1.197 | 1.197 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00768 | -32.70 | 0.00018 | 0.135 | 0.00 |
PERIMETER_TOP_ZN_4 | 17491.55 | 17491.55 | 86.60 | 0.779 | 0.779 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00767 | -32.70 | 0.00018 | 0.087 | 0.00 |
DATACENTER_BOT_ZN_6 | 0.00 | 0.00 | 0.00 | 0.000 | 0.016 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:30:00 | 18.00 | 24.20 | 0.00083 | -32.70 | 0.00018 | 0.016 | 0.00 |
DATACENTER_MID_ZN_6 | 0.00 | 0.00 | 0.00 | 0.000 | 0.156 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:40:00 | 18.00 | 22.22 | 0.00083 | -32.70 | 0.00018 | 0.156 | 0.00 |
DATACENTER_TOP_ZN_6 | 0.00 | 0.00 | 0.00 | 0.000 | 0.016 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 05:30:00 | 18.00 | 19.68 | 0.00083 | -32.70 | 0.00018 | 0.016 | 0.00 |
DATACENTER_BASEMENT_ZN_6 | 0.00 | 0.00 | 0.00 | 0.000 | 0.338 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 10:20:00 | 18.00 | 27.00 | 0.00850 | -32.70 | 0.00018 | 0.338 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
VAV_BOT WITH REHEAT | 10.11 | 10.11 | 3.16 | 3.16 | 10.1100 | 3.5809 | 10.1100 | 0.3542 | 0.3000 |
VAV_MID WITH REHEAT | 93.88 | 93.88 | 45.65 | 45.65 | 93.8786 | 45.6507 | 93.8786 | 0.4863 | 0.3000 |
VAV_TOP WITH REHEAT | 10.04 | 10.04 | 7.52 | 7.52 | 10.0436 | 7.5213 | 10.0436 | 0.7489 | 0.3000 |
CAV_BAS | 5.91 | 5.91 | 1.20 | 1.20 | 5.9096 | 5.9096 | 5.9096 | 1.0000 | 1.0000 |
AIRLOOP DATACENTER BASEMENT | 22.28 | 22.28 | 0.34 | 0.34 | 22.2821 | 22.2820 | 22.2821 | 1.0000 | 1.0000 |
AIRLOOP DATACENTER BOT | 0.52 | 0.52 | 0.02 | 0.02 | 0.5244 | 0.5244 | 0.5244 | 1.0000 | 1.0000 |
AIRLOOP DATACENTER MID | 5.03 | 5.03 | 0.16 | 0.16 | 5.0273 | 5.0273 | 5.0273 | 1.0000 | 1.0000 |
AIRLOOP DATACENTER TOP | 0.51 | 0.51 | 0.02 | 0.02 | 0.5099 | 0.5099 | 0.5099 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_BOTTOM VAV BOX | 28719.175 | 28719.175 | 1.955145 | 0.00025125 | 610.384 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 28719.18 | 28719.18 | 1.955145 | 12.80 | 11.22 | 0.00800000 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 21.00 | 0.00799992 | 49.5590 | 9854.57 | 0.00 | 28820.39 | 28820.39 |
CORE_MID VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_MID VAV BOX | 546187.568 | 546187.568 | 19.177330 | 0.00477829 | 13699.224 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 546187.57 | 546187.57 | 19.177330 | 12.80 | 11.22 | 0.00800000 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 21.00 | 0.00800000 | 49.5595 | 361151.29 | 0.00 | 547887.20 | 547887.20 |
CORE_TOP VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_TOP VAV BOX | 115129.537 | 115129.537 | 3.578960 | 0.00100720 | 3038.051 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 115129.54 | 115129.54 | 3.578960 | 12.80 | 11.22 | 0.00800000 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 21.00 | 0.00800000 | 49.5595 | 80597.23 | 0.00 | 115520.08 | 115520.08 |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_3 VAV BOX | 19997.964 | 19997.964 | 0.622329 | 0.00017495 | 527.450 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 19997.96 | 19997.96 | 0.622329 | 12.80 | 11.22 | 0.00800000 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 21.00 | 0.00776291 | 48.1119 | 13996.63 | 0.00 | 20063.94 | 20063.94 |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_2 VAV BOX | 13718.592 | 13718.592 | 0.426975 | 0.00012002 | 361.808 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 13718.59 | 13718.59 | 0.426975 | 12.80 | 11.22 | 0.00800000 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 21.00 | 0.00777670 | 48.1962 | 9601.01 | 0.00 | 13763.69 | 13763.69 |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_1 VAV BOX | 21947.418 | 21947.418 | 0.683114 | 0.00019201 | 578.821 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21947.42 | 21947.42 | 0.683114 | 12.80 | 11.22 | 0.00800000 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 21.00 | 0.00779356 | 48.2992 | 15359.47 | 0.00 | 22019.50 | 22019.50 |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_4 VAV BOX | 12469.380 | 12469.380 | 0.468565 | 0.00010909 | 305.187 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 12469.38 | 12469.38 | 0.468565 | 12.80 | 11.22 | 0.00800000 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 21.00 | 0.00767760 | 47.5905 | 7951.71 | 0.00 | 12509.51 | 12509.51 |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_3 VAV BOX | 287082.775 | 287082.775 | 8.940527 | 0.00251153 | 7569.303 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 287082.78 | 287082.78 | 8.940527 | 12.80 | 11.22 | 0.00800000 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 21.00 | 0.00765210 | 47.4360 | 200892.77 | 0.00 | 288011.48 | 288011.48 |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_2 VAV BOX | 190404.407 | 190404.407 | 5.929968 | 0.00166574 | 5020.152 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 190404.41 | 190404.41 | 5.929968 | 12.80 | 11.22 | 0.00800000 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 21.00 | 0.00765083 | 47.4283 | 133237.73 | 0.00 | 191019.62 | 191019.62 |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_1 VAV BOX | 290029.286 | 290029.286 | 9.032417 | 0.00253730 | 7646.942 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 290029.29 | 290029.29 | 9.032417 | 12.80 | 11.22 | 0.00800000 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 21.00 | 0.00765564 | 47.4577 | 202952.83 | 0.00 | 290967.17 | 290967.17 |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_4 VAV BOX | 186173.951 | 186173.951 | 5.798071 | 0.00162873 | 4908.669 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 186173.95 | 186173.95 | 5.798071 | 12.80 | 11.22 | 0.00800000 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 21.00 | 0.00764290 | 47.3798 | 130279.73 | 0.00 | 186775.90 | 186775.90 |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_3 VAV BOX | 38033.074 | 38033.074 | 1.184873 | 0.00033273 | 1002.628 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 38033.07 | 37922.37 | 1.184873 | 12.80 | 11.22 | 0.00800000 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 21.00 | 0.00767445 | 47.5738 | 26610.44 | 0.00 | 38154.94 | 38154.94 |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_2 VAV BOX | 25094.301 | 25094.301 | 0.781804 | 0.00021954 | 661.527 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 25094.30 | 25094.30 | 0.781804 | 12.80 | 11.22 | 0.00800000 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 21.00 | 0.00767115 | 47.5537 | 17557.50 | 0.00 | 25174.64 | 25174.64 |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_1 VAV BOX | 38414.876 | 38414.876 | 1.196779 | 0.00033607 | 1012.688 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 38414.88 | 38414.88 | 1.196779 | 12.80 | 11.22 | 0.00800000 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 21.00 | 0.00767755 | 47.5927 | 26877.39 | 0.00 | 38537.93 | 38537.93 |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_4 VAV BOX | 25000.021 | 25000.021 | 0.778868 | 0.00021871 | 659.041 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 25000.02 | 25000.02 | 0.778868 | 12.80 | 11.22 | 0.00800000 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 21.00 | 0.00767013 | 47.5475 | 17491.55 | 0.00 | 25080.06 | 25080.06 |
VAV_BOT WITH REHEAT COOLING COIL | Coil:Cooling:Water | AirLoopHVAC | VAV_BOT WITH REHEAT | 215745.208 | -999.000 | 10.110046 | 0.00917830 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 215745.21 | 174900.24 | 10.110046 | 25.58 | 17.62 | 0.00986775 | 10.88 | 10.88 | 0.00850000 | 30.10 | 0.01272586 | 21.13 | 25.1056 | 24.00 | 0.00886784 | 45.7218 | 129164.59 | 0.00 | 222201.69 | 169268.03 |
VAV_BOT WITH REHEAT HEATING COIL | Coil:Heating:Water | AirLoopHVAC | VAV_BOT WITH REHEAT | 129814.533 | 129814.533 | 3.033014 | 0.00113567 | 1867.900 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 06:50:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 129814.53 | 129814.53 | 3.033014 | -24.11 | -24.11 | 0.00141204 | 12.80 | 11.22 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 83.6854 | 19.77 | 0.00766719 | 51.2653 | 35932.83 | 0.00 | 97238.56 | 97238.56 |
VAV_MID WITH REHEAT COOLING COIL | Coil:Cooling:Water | AirLoopHVAC | VAV_MID WITH REHEAT | 2064211.473 | -999.000 | 93.878592 | 0.08781633 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 2064211.47 | 1641495.97 | 93.878592 | 25.73 | 17.79 | 0.01002365 | 10.87 | 10.87 | 0.00850000 | 30.10 | 0.01272586 | 21.13 | 27.0370 | 24.00 | 0.00895194 | 46.1499 | 1178815.57 | 0.00 | 2124933.50 | 1591561.48 |
VAV_MID WITH REHEAT HEATING COIL | Coil:Heating:Water | AirLoopHVAC | VAV_MID WITH REHEAT | 1312673.622 | 1312673.622 | 28.163578 | 0.01148384 | 18441.221 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 22:20:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 1312673.62 | 1312673.62 | 28.163578 | -27.40 | -27.40 | 0.00091905 | 12.80 | 11.22 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 90.1233 | 18.04 | 0.00754408 | 56.2200 | 460030.96 | 0.00 | 953685.42 | 953685.42 |
VAV_TOP WITH REHEAT COOLING COIL | Coil:Cooling:Water | AirLoopHVAC | VAV_TOP WITH REHEAT | 214361.483 | -999.000 | 10.043570 | 0.00911943 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | 214361.48 | 173299.60 | 10.043570 | 25.54 | 17.62 | 0.00988416 | 10.88 | 10.88 | 0.00850000 | 30.10 | 0.01272586 | 21.13 | 25.2718 | 24.00 | 0.00892166 | 45.9962 | 132309.29 | 0.00 | 220776.71 | 167740.25 |
VAV_TOP WITH REHEAT HEATING COIL | Coil:Heating:Water | AirLoopHVAC | VAV_TOP WITH REHEAT | 131950.323 | 131950.323 | 3.013071 | 0.00115436 | 1886.544 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 03:40:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 131950.32 | 131950.32 | 3.013071 | -24.97 | -24.97 | 0.00134092 | 12.80 | 11.22 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 84.2393 | 15.60 | 0.00721538 | 62.8256 | 44026.99 | 0.00 | 98045.99 | 98045.99 |
CAV_BAS COOLING COIL | Coil:Cooling:Water | AirLoopHVAC | CAV_BAS | 120013.430 | -999.000 | 5.909618 | 0.00510565 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 120013.43 | 97206.57 | 5.909618 | 25.25 | 17.49 | 0.00984370 | 11.36 | 11.13 | 0.00850000 | 29.48 | 0.01272477 | 20.95 | 20.3085 | 24.00 | 0.00898903 | 46.3376 | 69188.48 | 0.00 | 123687.12 | 94778.99 |
CAV_BAS HEATING COIL | Coil:Heating:Water | AirLoopHVAC | CAV_BAS | 319601.401 | 319601.401 | 5.909618 | 0.00279601 | 6737.172 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 319601.40 | 319601.40 | 5.909618 | -6.64 | -10.59 | 0.00018338 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 20.3085 | 22.82 | 0.00018338 | 1.0296 | 0.00 | 0.00 | 250447.76 | 250447.76 |
AIRLOOP DATACENTER BASEMENT COOLING COIL | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AirLoopHVAC | AIRLOOP DATACENTER BASEMENT | 436569.556 | 301670.861 | 22.282147 | 0.01069156 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 07:10:00 | 403498.09 | 397500.37 | -999.0 | 28.50 | 17.57 | 0.00860578 | 12.80 | 11.72 | 0.00850000 | 30.10 | 0.01272586 | 21.13 | -999.0000 | 27.00 | 0.00854217 | 36.8766 | 372159.10 | 0.00 | -999.00 | -999.00 |
AIRLOOP DATACENTER BOT COOLING COIL | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AirLoopHVAC | AIRLOOP DATACENTER BOT | 10097.063 | 7032.298 | 0.524438 | 0.00024728 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:20:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:20:00 | 9303.77 | 9029.70 | -999.0 | 27.92 | 17.46 | 0.00870586 | 12.80 | 11.72 | 0.00850000 | 24.81 | 0.01271660 | 19.55 | -999.0000 | 27.00 | 0.00858263 | 37.0464 | 8769.73 | 0.00 | -999.00 | -999.00 |
AIRLOOP DATACENTER MID COOLING COIL | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AirLoopHVAC | AIRLOOP DATACENTER MID | 96893.413 | 67443.173 | 5.027343 | 0.00237291 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:20:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:20:00 | 89295.79 | 86556.04 | -999.0 | 27.92 | 17.47 | 0.00871465 | 12.80 | 11.72 | 0.00850000 | 24.81 | 0.01271660 | 19.55 | -999.0000 | 27.00 | 0.00858621 | 37.0618 | 84067.62 | 0.00 | -999.00 | -999.00 |
AIRLOOP DATACENTER TOP COOLING COIL | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AirLoopHVAC | AIRLOOP DATACENTER TOP | 9826.636 | 6840.097 | 0.509870 | 0.00024065 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:10:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:10:00 | 9056.13 | 8782.39 | -999.0 | 27.93 | 17.47 | 0.00871147 | 12.80 | 11.72 | 0.00850000 | 25.04 | 0.01271700 | 19.62 | -999.0000 | 27.00 | 0.00858477 | 37.0556 | 8526.09 | 0.00 | -999.00 | -999.00 |
AIRLOOP DATACENTER BASEMENT HEATING COIL | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AirLoopHVAC | AIRLOOP DATACENTER BASEMENT | 436569.556 | 436569.556 | 22.282147 | 0.01069156 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 436569.56 | 436569.56 | 22.282147 | -32.70 | -32.70 | 0.00018338 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 1.5187 | 27.00 | 0.00850000 | 36.6913 | 0.00 | 0.00 | -999.00 | -999.00 |
AIRLOOP DATACENTER BOT HEATING COIL | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AirLoopHVAC | AIRLOOP DATACENTER BOT | 10097.063 | 10097.063 | 0.524438 | 0.00024728 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 10097.06 | 10097.06 | 0.524438 | -32.70 | -32.70 | 0.00018338 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 2.9808 | 25.07 | 0.00082597 | 4.0467 | 0.00 | 0.00 | -999.00 | -999.00 |
AIRLOOP DATACENTER MID HEATING COIL | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AirLoopHVAC | AIRLOOP DATACENTER MID | 96893.413 | 96893.413 | 5.027343 | 0.00237291 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 96893.41 | 96893.41 | 5.027343 | -32.70 | -32.70 | 0.00018338 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 3.1095 | 23.49 | 0.00082600 | 4.4479 | 0.00 | 0.00 | -999.00 | -999.00 |
AIRLOOP DATACENTER TOP HEATING COIL | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AirLoopHVAC | AIRLOOP DATACENTER TOP | 9826.636 | 9826.636 | 0.509870 | 0.00024065 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 9826.64 | 9826.64 | 0.509870 | -32.70 | -32.70 | 0.00018338 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 3.0659 | 21.95 | 0.00082529 | 4.8793 | 0.00 | 0.00 | -999.00 | -999.00 |
AIRLOOP DATACENTER BASEMENT_SUPPHEATCOIL | Coil:Heating:Electric | AirLoopHVAC | AIRLOOP DATACENTER BASEMENT | 28525.808 | 28525.808 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 28525.81 | 28525.81 | 22.282147 | -0.50 | -0.50 | 0.00837370 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 1.5187 | 27.00 | 0.00850000 | 36.6913 | 0.00 | 0.00 | -999.00 | -999.00 |
AIRLOOP DATACENTER BOT_SUPPHEATCOIL | Coil:Heating:Electric | AirLoopHVAC | AIRLOOP DATACENTER BOT | 1317.774 | 1317.774 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 1317.77 | 1317.77 | 0.524438 | -0.97 | -5.60 | 0.00080682 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 2.9808 | 25.07 | 0.00082597 | 4.0467 | 0.00 | 0.00 | -999.00 | -999.00 |
AIRLOOP DATACENTER MID_SUPPHEATCOIL | Coil:Heating:Electric | AirLoopHVAC | AIRLOOP DATACENTER MID | 13177.742 | 13177.742 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 13177.74 | 13177.74 | 5.027343 | -1.02 | -5.63 | 0.00080602 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 3.1095 | 23.49 | 0.00082600 | 4.4479 | 0.00 | 0.00 | -999.00 | -999.00 |
AIRLOOP DATACENTER TOP_SUPPHEATCOIL | Coil:Heating:Electric | AirLoopHVAC | AIRLOOP DATACENTER TOP | 1317.774 | 1317.774 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | 1317.77 | 1317.77 | 0.509870 | -1.00 | -5.62 | 0.00080560 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 3.0659 | 21.95 | 0.00082529 | 4.8793 | 0.00 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
CORE_BOTTOM VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_BOTTOM VAV BOX | CORE_BOTTOM | N/A | N/A | N/A | Yes | Yes | Yes | No | 28719.175 | 28719.175 | 1.955145 | 0.00025125 | 610.384 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 0.7543 | 0.769447 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 28719.18 | 28719.18 | 1.0000 | 2.25609026 | 1.955145 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | 0.25122224 | 60.00 | 32.22 | 27.78 | 0.000 | 28719.18 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 20.76 | 0.00799992 | 21.00 | 0.00799992 | 49.5590 | 9854.57 | 0.00 | 28820.39 | 28820.39 | 2.25609026 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 25.33 | 16.43 | 0.00800000 | 45834.3 | |
CORE_MID VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_MID VAV BOX | CORE_MID | N/A | N/A | N/A | Yes | Yes | Yes | No | 546187.568 | 546187.568 | 19.177330 | 0.00477829 | 13699.224 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 14.3448 | 14.633517 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 546187.57 | 546187.57 | 1.0000 | 22.12919789 | 19.177330 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | 4.77779968 | 60.00 | 32.22 | 27.78 | 0.000 | 546187.57 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 20.87 | 0.00800000 | 21.00 | 0.00800000 | 49.5595 | 361151.29 | 0.00 | 547887.20 | 547887.20 | 22.12919789 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 37.08 | 20.30 | 0.00800000 | 57818.4 | |
CORE_TOP VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_TOP VAV BOX | CORE_TOP | N/A | N/A | N/A | Yes | Yes | Yes | No | 115129.537 | 115129.537 | 3.578960 | 0.00100720 | 3038.051 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 3.0237 | 3.084563 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 115129.54 | 115129.54 | 1.0000 | 4.12985093 | 3.578960 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | 1.00710067 | 60.00 | 32.22 | 27.78 | 0.000 | 115129.54 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 20.91 | 0.00800000 | 21.00 | 0.00800000 | 49.5595 | 80597.23 | 0.00 | 115520.08 | 115520.08 | 4.12985093 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.23 | 21.25 | 0.00800000 | 61031.8 | |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_3 VAV BOX | PERIMETER_BOT_ZN_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 19997.964 | 19997.964 | 0.622329 | 0.00017495 | 527.450 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 0.5252 | 0.535788 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 19997.96 | 19997.96 | 1.0000 | 0.71812094 | 0.622329 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | 0.17493307 | 60.00 | 32.22 | 27.78 | 0.000 | 19997.96 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 20.95 | 0.00776291 | 21.00 | 0.00776291 | 48.1119 | 13996.63 | 0.00 | 20063.94 | 20063.94 | 0.71812094 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.20 | 21.24 | 0.00800000 | 60999.3 | |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_2 VAV BOX | PERIMETER_BOT_ZN_2 | N/A | N/A | N/A | Yes | Yes | Yes | No | 13718.592 | 13718.592 | 0.426975 | 0.00012002 | 361.808 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 0.3603 | 0.367550 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 13718.59 | 13718.59 | 1.0000 | 0.49269675 | 0.426975 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | 0.12000398 | 60.00 | 32.22 | 27.78 | 0.000 | 13718.59 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 20.95 | 0.00777670 | 21.00 | 0.00777670 | 48.1962 | 9601.01 | 0.00 | 13763.69 | 13763.69 | 0.49269675 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.20 | 21.24 | 0.00800000 | 60995.3 | |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_1 VAV BOX | PERIMETER_BOT_ZN_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 21947.418 | 21947.418 | 0.683114 | 0.00019201 | 578.821 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 0.5764 | 0.588018 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 21947.42 | 21947.42 | 1.0000 | 0.78826278 | 0.683114 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | 0.19198600 | 60.00 | 32.22 | 27.78 | 0.000 | 21947.42 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 20.95 | 0.00779356 | 21.00 | 0.00779356 | 48.2992 | 15359.47 | 0.00 | 22019.50 | 22019.50 | 0.78826278 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.19 | 21.24 | 0.00800000 | 60994.0 | |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_4 VAV BOX | PERIMETER_BOT_ZN_4 | N/A | N/A | N/A | Yes | Yes | Yes | No | 12469.380 | 12469.380 | 0.468565 | 0.00010909 | 305.187 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 0.3275 | 0.334081 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 12469.38 | 12469.38 | 1.0000 | 0.54068935 | 0.468565 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | 0.10907645 | 60.00 | 32.22 | 27.78 | 0.000 | 12469.38 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 20.95 | 0.00767760 | 21.00 | 0.00767760 | 47.5905 | 7951.71 | 0.00 | 12509.51 | 12509.51 | 0.54068935 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 35.49 | 19.81 | 0.00800000 | 56196.0 | |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_3 VAV BOX | PERIMETER_MID_ZN_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 287082.775 | 287082.775 | 8.940527 | 0.00251153 | 7569.303 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 7.5398 | 7.691553 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 287082.78 | 287082.78 | 1.0000 | 10.31669609 | 8.940527 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | 2.51126915 | 60.00 | 32.22 | 27.78 | 0.000 | 287082.78 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 20.95 | 0.00765210 | 21.00 | 0.00765210 | 47.4360 | 200892.77 | 0.00 | 288011.48 | 288011.48 | 10.31669609 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.18 | 21.23 | 0.00800000 | 60976.9 | |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_2 VAV BOX | PERIMETER_MID_ZN_2 | N/A | N/A | N/A | Yes | Yes | Yes | No | 190404.407 | 190404.407 | 5.929968 | 0.00166574 | 5020.152 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 5.0007 | 5.101336 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 190404.41 | 190404.41 | 1.0000 | 6.84273757 | 5.929968 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | 1.66557089 | 60.00 | 32.22 | 27.78 | 0.000 | 190404.41 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 20.95 | 0.00765083 | 21.00 | 0.00765083 | 47.4283 | 133237.73 | 0.00 | 191019.62 | 191019.62 | 6.84273757 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.18 | 21.23 | 0.00800000 | 60975.5 | |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_1 VAV BOX | PERIMETER_MID_ZN_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 290029.286 | 290029.286 | 9.032417 | 0.00253730 | 7646.942 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 7.6172 | 7.770496 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 290029.29 | 290029.29 | 1.0000 | 10.42273017 | 9.032417 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | 2.53704389 | 60.00 | 32.22 | 27.78 | 0.000 | 290029.29 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 20.95 | 0.00765564 | 21.00 | 0.00765564 | 47.4577 | 202952.83 | 0.00 | 290967.17 | 290967.17 | 10.42273017 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.18 | 21.23 | 0.00800000 | 60976.4 | |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_4 VAV BOX | PERIMETER_MID_ZN_4 | N/A | N/A | N/A | Yes | Yes | Yes | No | 186173.951 | 186173.951 | 5.798071 | 0.00162873 | 4908.669 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 4.8896 | 4.987993 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 186173.95 | 186173.95 | 1.0000 | 6.69053843 | 5.798071 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | 1.62856479 | 60.00 | 32.22 | 27.78 | 0.000 | 186173.95 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 20.95 | 0.00764290 | 21.00 | 0.00764290 | 47.3798 | 130279.73 | 0.00 | 186775.90 | 186775.90 | 6.69053843 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.18 | 21.23 | 0.00800000 | 60976.3 | |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_3 VAV BOX | PERIMETER_TOP_ZN_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 38033.074 | 38033.074 | 1.184873 | 0.00033273 | 1002.628 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 0.9989 | 1.018986 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 38033.07 | 37922.37 | 1.0000 | 1.36725400 | 1.184873 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | 0.33269598 | 60.00 | 32.22 | 27.78 | 0.000 | 38033.07 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 20.95 | 0.00767445 | 21.00 | 0.00767445 | 47.5738 | 26610.44 | 0.00 | 38154.94 | 38154.94 | 1.36725400 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.17 | 21.23 | 0.00800000 | 60966.1 | |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_2 VAV BOX | PERIMETER_TOP_ZN_2 | N/A | N/A | N/A | Yes | Yes | Yes | No | 25094.301 | 25094.301 | 0.781804 | 0.00021954 | 661.527 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 0.6591 | 0.672329 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 25094.30 | 25094.30 | 1.0000 | 0.90214285 | 0.781804 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | 0.21951350 | 60.00 | 32.22 | 27.78 | 0.000 | 25094.30 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 20.95 | 0.00767115 | 21.00 | 0.00767115 | 47.5537 | 17557.50 | 0.00 | 25174.64 | 25174.64 | 0.90214285 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.17 | 21.23 | 0.00800000 | 60965.2 | |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_1 VAV BOX | PERIMETER_TOP_ZN_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 38414.876 | 38414.876 | 1.196779 | 0.00033607 | 1012.688 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 1.0089 | 1.029216 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 38414.88 | 38414.88 | 1.0000 | 1.38099323 | 1.196779 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | 0.33603581 | 60.00 | 32.22 | 27.78 | 0.000 | 38414.88 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 20.95 | 0.00767755 | 21.00 | 0.00767755 | 47.5927 | 26877.39 | 0.00 | 38537.93 | 38537.93 | 1.38099323 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.17 | 21.23 | 0.00800000 | 60965.8 | |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_4 VAV BOX | PERIMETER_TOP_ZN_4 | N/A | N/A | N/A | Yes | Yes | Yes | No | 25000.021 | 25000.021 | 0.778868 | 0.00021871 | 659.041 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 0.6566 | 0.669803 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 25000.02 | 25000.02 | 1.0000 | 0.89875480 | 0.778868 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | 0.21868878 | 60.00 | 32.22 | 27.78 | 0.000 | 25000.02 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 20.95 | 0.00767013 | 21.00 | 0.00767013 | 47.5475 | 17491.55 | 0.00 | 25080.06 | 25080.06 | 0.89875480 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.17 | 21.23 | 0.00800000 | 60965.2 | |
VAV_BOT WITH REHEAT COOLING COIL | Coil:Cooling:Water | AirLoop | AirLoopHVAC | VAV_BOT WITH REHEAT | CORE_BOTTOM; PERIMETER_BOT_ZN_3; PERIMETER_BOT_ZN_2; PERIMETER_BOT_ZN_1; PERIMETER_BOT_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | Yes | No | 215745.208 | -999.000 | 10.110046 | 0.00917830 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.1837 | 1004.8586 | 1.1539 | VAV_BOT WITH REHEAT FAN | Fan:VariableVolume | 10.110046 | 11.66623335 | 4197.9300 | 999.8980 | 111.20836398 | 12.27 | 6.67 | 5.60 | 2614331.59 | 8.2524 | 8.252404 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | Sensible | 215745.21 | 174900.24 | 1.0000 | 11.66623335 | 10.110046 | 25.58 | 17.62 | 0.00986775 | 50851.6 | 10.88 | 10.88 | 0.00850000 | 32358.5 | 9.17736362 | 6.67 | 12.27 | 5.60 | 22965.912 | 192779.30 | 30.10 | 0.01272586 | 21.13 | 2.53819000 | 25.1056 | 24.00 | 0.00886784 | 24.00 | 0.00886784 | 45.7218 | 129164.59 | 0.00 | 222201.69 | 169268.03 | 11.66623335 | 25.58 | 18.07 | 0.00986775 | 50851.6 | 11.40 | 11.07 | 0.00806874 | 31805.1 | |
VAV_BOT WITH REHEAT HEATING COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | VAV_BOT WITH REHEAT | CORE_BOTTOM; PERIMETER_BOT_ZN_3; PERIMETER_BOT_ZN_2; PERIMETER_BOT_ZN_1; PERIMETER_BOT_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 129814.533 | 129814.533 | 3.033014 | 0.00113567 | 1867.900 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | VAV_BOT WITH REHEAT FAN | Fan:VariableVolume | 10.110046 | 11.66623335 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 3.4094 | 3.478005 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 06:50:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 129814.53 | 129814.53 | 1.0000 | 3.49987001 | 3.033014 | -24.11 | -24.11 | 0.00141204 | -20760.5 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 1.13555832 | 60.00 | 32.22 | 27.78 | 0.000 | 129814.53 | -32.70 | 0.00018338 | -32.70 | 2.53819000 | 83.6854 | 19.94 | 0.00771447 | 19.77 | 0.00766719 | 51.2653 | 35932.83 | 0.00 | 97238.56 | 97238.56 | 3.49987001 | 2.80 | -2.12 | 0.00141204 | 6352.3 | 30.38 | 12.18 | 0.00141204 | 34135.8 | |
VAV_MID WITH REHEAT COOLING COIL | Coil:Cooling:Water | AirLoop | AirLoopHVAC | VAV_MID WITH REHEAT | CORE_MID; PERIMETER_MID_ZN_3; PERIMETER_MID_ZN_2; PERIMETER_MID_ZN_1; PERIMETER_MID_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | Yes | No | 2064211.473 | -999.000 | 93.878592 | 0.08781633 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.4735 | 1004.8586 | 1.1539 | VAV_MID WITH REHEAT FAN | Fan:VariableVolume | 93.878592 | 108.32884097 | 4197.9300 | 999.8980 | 111.20836398 | 12.27 | 6.67 | 5.60 | 2614331.59 | 78.9575 | 78.957523 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | Sensible | 2064211.47 | 1641495.97 | 1.0000 | 108.32884097 | 93.878592 | 25.73 | 17.79 | 0.01002365 | 51403.6 | 10.87 | 10.87 | 0.00850000 | 32348.6 | 87.80736972 | 6.67 | 12.27 | 5.60 | 214393.152 | 1849818.32 | 30.10 | 0.01272586 | 21.13 | 25.38195000 | 27.0370 | 24.00 | 0.00895194 | 24.00 | 0.00895194 | 46.1499 | 1178815.57 | 0.00 | 2124933.50 | 1591561.48 | 108.32884097 | 25.73 | 18.25 | 0.01002365 | 51403.6 | 11.38 | 11.06 | 0.00807144 | 31788.0 | |
VAV_MID WITH REHEAT HEATING COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | VAV_MID WITH REHEAT | CORE_MID; PERIMETER_MID_ZN_3; PERIMETER_MID_ZN_2; PERIMETER_MID_ZN_1; PERIMETER_MID_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 1312673.622 | 1312673.622 | 28.163578 | 0.01148384 | 18441.221 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | VAV_MID WITH REHEAT FAN | Fan:VariableVolume | 93.878592 | 108.32884097 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 34.4755 | 35.169295 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 22:20:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 1312673.62 | 1312673.62 | 1.0000 | 32.49865229 | 28.163578 | -27.40 | -27.40 | 0.00091905 | -25277.3 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 11.48267001 | 60.00 | 32.22 | 27.78 | 0.000 | 1312673.62 | -32.70 | 0.00018338 | -32.70 | 25.38195000 | 90.1233 | 21.00 | 0.00763194 | 18.04 | 0.00754408 | 56.2200 | 460030.96 | 0.00 | 953685.42 | 953685.42 | 32.49865229 | 2.80 | -2.92 | 0.00091905 | 5116.8 | 31.95 | 12.32 | 0.00091905 | 34462.2 | |
VAV_TOP WITH REHEAT COOLING COIL | Coil:Cooling:Water | AirLoop | AirLoopHVAC | VAV_TOP WITH REHEAT | CORE_TOP; PERIMETER_TOP_ZN_3; PERIMETER_TOP_ZN_2; PERIMETER_TOP_ZN_1; PERIMETER_TOP_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | Yes | No | 214361.483 | -999.000 | 10.043570 | 0.00911943 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.2142 | 1004.8586 | 1.1539 | VAV_TOP WITH REHEAT FAN | Fan:VariableVolume | 10.043570 | 11.58952459 | 4197.9300 | 999.8980 | 111.20836398 | 12.27 | 6.67 | 5.60 | 2614331.59 | 8.1995 | 8.199476 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | Sensible | 214361.48 | 173299.60 | 1.0000 | 11.58952459 | 10.043570 | 25.54 | 17.62 | 0.00988416 | 50854.7 | 10.88 | 10.88 | 0.00850000 | 32358.6 | 9.11850274 | 6.67 | 12.27 | 5.60 | 22814.905 | 191546.58 | 30.10 | 0.01272586 | 21.13 | 2.53819000 | 25.2718 | 24.00 | 0.00892166 | 24.00 | 0.00892166 | 45.9962 | 132309.29 | 0.00 | 220776.71 | 167740.25 | 11.58952459 | 25.54 | 18.07 | 0.00988416 | 50854.7 | 11.40 | 11.07 | 0.00806972 | 31805.0 | |
VAV_TOP WITH REHEAT HEATING COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | VAV_TOP WITH REHEAT | CORE_TOP; PERIMETER_TOP_ZN_3; PERIMETER_TOP_ZN_2; PERIMETER_TOP_ZN_1; PERIMETER_TOP_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 131950.323 | 131950.323 | 3.013071 | 0.00115436 | 1886.544 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | VAV_TOP WITH REHEAT FAN | Fan:VariableVolume | 10.043570 | 11.58952459 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 3.4655 | 3.535227 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 03:40:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 131950.32 | 131950.32 | 1.0000 | 3.47685738 | 3.013071 | -24.97 | -24.97 | 0.00134092 | -21797.0 | 12.80 | 11.22 | 0.00800000 | 33059.8 | 1.15424123 | 60.00 | 32.22 | 27.78 | 0.000 | 131950.32 | -32.70 | 0.00018338 | -32.70 | 2.53819000 | 84.2393 | 16.36 | 0.00752791 | 15.60 | 0.00721538 | 62.8256 | 44026.99 | 0.00 | 98045.99 | 98045.99 | 3.47685738 | 2.80 | -2.23 | 0.00134092 | 6174.1 | 30.79 | 12.28 | 0.00134092 | 34373.7 | |
CAV_BAS COOLING COIL | Coil:Cooling:Water | AirLoop | AirLoopHVAC | CAV_BAS | BASEMENT | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | Yes | No | 120013.430 | -999.000 | 5.909618 | 0.00510565 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.1390 | 1004.8586 | 1.1539 | CAV_BAS FAN | Fan:ConstantVolume | 5.909618 | 6.81925458 | 4197.9300 | 999.8980 | 111.20836398 | 12.27 | 6.67 | 5.60 | 2614331.59 | 4.5906 | 4.590597 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | Sensible | 120013.43 | 97206.57 | 1.0000 | 6.81925458 | 5.909618 | 25.25 | 17.49 | 0.00984370 | 50455.5 | 11.36 | 11.13 | 0.00850000 | 32856.3 | 5.10512790 | 6.67 | 12.27 | 5.60 | 10020.669 | 109992.76 | 29.48 | 0.01272477 | 20.95 | 1.20015641 | 20.3085 | 24.00 | 0.00898903 | 24.00 | 0.00898903 | 46.3376 | 69188.48 | 0.00 | 123687.12 | 94778.99 | 6.81925458 | 25.25 | 17.94 | 0.00984370 | 50455.5 | 11.67 | 11.28 | 0.00816324 | 32317.6 | |
CAV_BAS HEATING COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | CAV_BAS | BASEMENT | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 319601.401 | 319601.401 | 5.909618 | 0.00279601 | 6737.172 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | CAV_BAS FAN | Fan:ConstantVolume | 5.909618 | 6.81925458 | 4197.9300 | 999.8980 | 32.64970169 | 54.44 | 82.22 | 27.78 | 3807559.09 | 8.3939 | 8.562796 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 319601.40 | 319601.40 | 1.0000 | 6.81925458 | 5.909618 | -6.64 | -10.59 | 0.00018338 | -6216.7 | 40.00 | 20.69 | 0.00800000 | 60796.0 | 2.79572725 | 60.00 | 32.22 | 27.78 | 0.000 | 319601.40 | -32.70 | 0.00018338 | -32.70 | 1.20015641 | 20.3085 | 0.00 | 0.00018338 | 22.82 | 0.00018338 | 1.0296 | 0.00 | 0.00 | 250447.76 | 250447.76 | 6.81925458 | 12.80 | 2.24 | 0.00018338 | 13324.9 | 49.34 | 18.06 | 0.00018338 | 50051.5 | |
AIRLOOP DATACENTER BASEMENT COOLING COIL | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AirLoop | AirLoopHVAC | AIRLOOP DATACENTER BASEMENT | DATACENTER_BASEMENT_ZN_6 | Coincident | CoolingDesignCapacity | N/A | Yes | No | unknown | No | 436569.556 | 301670.861 | 22.282147 | 0.01069156 | -999.000 | -999.0000 | -999.00000 | -999.00000 | 1020.8377 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 07:10:00 | Sensible | 403498.09 | 397500.37 | 0.9242 | -999.0 | -999.0 | 28.50 | 17.57 | 0.00860578 | 50614.4 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 403498.09 | 30.10 | 0.01272586 | 21.13 | 0.33839277 | -999.0000 | 27.00 | 0.00854217 | 27.00 | 0.00854217 | 36.8766 | 372159.10 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
AIRLOOP DATACENTER BOT COOLING COIL | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AirLoop | AirLoopHVAC | AIRLOOP DATACENTER BOT | DATACENTER_BOT_ZN_6 | Coincident | CoolingDesignCapacity | N/A | Yes | No | unknown | No | 10097.063 | 7032.298 | 0.524438 | 0.00024728 | -999.000 | -999.0000 | -999.00000 | -999.00000 | 1021.0238 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:20:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:20:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:20:00 | Sensible | 9303.77 | 9029.70 | 0.9214 | -999.0 | -999.0 | 27.92 | 17.46 | 0.00870586 | 50279.8 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9303.77 | 24.81 | 0.01271660 | 19.55 | 0.01563234 | -999.0000 | 27.00 | 0.00858263 | 27.00 | 0.00858263 | 37.0464 | 8769.73 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
AIRLOOP DATACENTER MID COOLING COIL | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AirLoop | AirLoopHVAC | AIRLOOP DATACENTER MID | DATACENTER_MID_ZN_6 | Coincident | CoolingDesignCapacity | N/A | Yes | No | unknown | No | 96893.413 | 67443.173 | 5.027343 | 0.00237291 | -999.000 | -999.0000 | -999.00000 | -999.00000 | 1021.0401 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:20:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:20:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:20:00 | Sensible | 89295.79 | 86556.04 | 0.9216 | -999.0 | -999.0 | 27.92 | 17.47 | 0.00871465 | 50299.3 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 89295.79 | 24.81 | 0.01271660 | 19.55 | 0.15632344 | -999.0000 | 27.00 | 0.00858621 | 27.00 | 0.00858621 | 37.0618 | 84067.62 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
AIRLOOP DATACENTER TOP COOLING COIL | COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT | AirLoop | AirLoopHVAC | AIRLOOP DATACENTER TOP | DATACENTER_TOP_ZN_6 | Coincident | CoolingDesignCapacity | N/A | Yes | No | unknown | No | 9826.636 | 6840.097 | 0.509870 | 0.00024065 | -999.000 | -999.0000 | -999.00000 | -999.00000 | 1021.0342 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:10:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:10:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:10:00 | Sensible | 9056.13 | 8782.39 | 0.9216 | -999.0 | -999.0 | 27.93 | 17.47 | 0.00871147 | 50299.3 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9056.13 | 25.04 | 0.01271700 | 19.62 | 0.01563234 | -999.0000 | 27.00 | 0.00858477 | 27.00 | 0.00858477 | 37.0556 | 8526.09 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
AIRLOOP DATACENTER BASEMENT HEATING COIL | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AirLoop | AirLoopHVAC | AIRLOOP DATACENTER BASEMENT | DATACENTER_BASEMENT_ZN_6 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 436569.556 | 436569.556 | 22.282147 | 0.01069156 | -999.000 | -999.0000 | -999.00000 | -999.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 436569.56 | 436569.56 | 1.0000 | 25.71192327 | 22.282147 | -32.70 | -32.70 | 0.00018338 | -32410.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 436569.56 | -32.70 | 0.00018338 | -32.70 | 0.33839277 | 1.5187 | 0.00 | 0.00850000 | 27.00 | 0.00850000 | 36.6913 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
AIRLOOP DATACENTER BOT HEATING COIL | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AirLoop | AirLoopHVAC | AIRLOOP DATACENTER BOT | DATACENTER_BOT_ZN_6 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 10097.063 | 10097.063 | 0.524438 | 0.00024728 | -999.000 | -999.0000 | -999.00000 | -999.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 10097.06 | 10097.06 | 1.0000 | 0.60516212 | 0.524438 | -32.70 | -32.70 | 0.00018338 | -32410.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10097.06 | -32.70 | 0.00018338 | -32.70 | 0.01563234 | 2.9808 | 0.00 | 0.00082597 | 25.07 | 0.00082597 | 4.0467 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
AIRLOOP DATACENTER MID HEATING COIL | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AirLoop | AirLoopHVAC | AIRLOOP DATACENTER MID | DATACENTER_MID_ZN_6 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 96893.413 | 96893.413 | 5.027343 | 0.00237291 | -999.000 | -999.0000 | -999.00000 | -999.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 96893.41 | 96893.41 | 1.0000 | 5.80117571 | 5.027343 | -32.70 | -32.70 | 0.00018338 | -32410.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 96893.41 | -32.70 | 0.00018338 | -32.70 | 0.15632344 | 3.1095 | 0.00 | 0.00082600 | 23.49 | 0.00082600 | 4.4479 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
AIRLOOP DATACENTER TOP HEATING COIL | COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT | AirLoop | AirLoopHVAC | AIRLOOP DATACENTER TOP | DATACENTER_TOP_ZN_6 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 9826.636 | 9826.636 | 0.509870 | 0.00024065 | -999.000 | -999.0000 | -999.00000 | -999.00000 | 1019.7116 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 9826.64 | 9826.64 | 1.0000 | 0.58835111 | 0.509870 | -32.70 | -32.70 | 0.00018338 | -32410.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9826.64 | -32.70 | 0.00018338 | -32.70 | 0.01563234 | 3.0659 | 0.00 | 0.00082529 | 21.95 | 0.00082529 | 4.8793 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
AIRLOOP DATACENTER BASEMENT_SUPPHEATCOIL | Coil:Heating:Electric | AirLoop | AirLoopHVAC | AIRLOOP DATACENTER BASEMENT | DATACENTER_BASEMENT_ZN_6 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 28525.808 | 28525.808 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | AIRLOOP DATACENTER BASEMENT SUPPLY FAN | Fan:OnOff | 22.282147 | 25.71192327 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 28525.81 | 28525.81 | 1.0000 | 25.71192327 | 22.282147 | -0.50 | -0.50 | 0.00837370 | 20435.4 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 28525.81 | -32.70 | 0.00018338 | -32.70 | 0.33839277 | 1.5187 | 0.00 | 0.00850000 | 27.00 | 0.00850000 | 36.6913 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
AIRLOOP DATACENTER BOT_SUPPHEATCOIL | Coil:Heating:Electric | AirLoop | AirLoopHVAC | AIRLOOP DATACENTER BOT | DATACENTER_BOT_ZN_6 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 1317.774 | 1317.774 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | AIRLOOP DATACENTER BOT SUPPLY FAN | Fan:OnOff | 0.524438 | 0.60516212 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 1317.77 | 1317.77 | 1.0000 | 0.60516212 | 0.524438 | -0.97 | -5.60 | 0.00080682 | 1036.9 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 1317.77 | -32.70 | 0.00018338 | -32.70 | 0.01563234 | 2.9808 | 0.00 | 0.00082597 | 25.07 | 0.00082597 | 4.0467 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
AIRLOOP DATACENTER MID_SUPPHEATCOIL | Coil:Heating:Electric | AirLoop | AirLoopHVAC | AIRLOOP DATACENTER MID | DATACENTER_MID_ZN_6 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 13177.742 | 13177.742 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | AIRLOOP DATACENTER MID SUPPLY FAN | Fan:OnOff | 5.027343 | 5.80117571 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 13177.74 | 13177.74 | 1.0000 | 5.80117571 | 5.027343 | -1.02 | -5.63 | 0.00080602 | 992.6 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 13177.74 | -32.70 | 0.00018338 | -32.70 | 0.15632344 | 3.1095 | 0.00 | 0.00082600 | 23.49 | 0.00082600 | 4.4479 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
AIRLOOP DATACENTER TOP_SUPPHEATCOIL | Coil:Heating:Electric | AirLoop | AirLoopHVAC | AIRLOOP DATACENTER TOP | DATACENTER_TOP_ZN_6 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 1317.774 | 1317.774 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | AIRLOOP DATACENTER TOP SUPPLY FAN | Fan:OnOff | 0.509870 | 0.58835111 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 00:10:00 | Sensible | 1317.77 | 1317.77 | 1.0000 | 0.58835111 | 0.509870 | -1.00 | -5.62 | 0.00080560 | 1005.8 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 1317.77 | -32.70 | 0.00018338 | -32.70 | 0.01563234 | 3.0659 | 0.00 | 0.00082529 | 21.95 | 0.00082529 | 4.8793 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
VAV_BOT WITH REHEAT_OA_CONTROLLER | DifferentialDryBulb | 2.54 | 10.11 | - | |||
VAV_MID WITH REHEAT_OA_CONTROLLER | DifferentialDryBulb | 25.38 | 93.88 | - | |||
VAV_TOP WITH REHEAT_OA_CONTROLLER | DifferentialDryBulb | 2.54 | 10.04 | - | |||
CAV_BAS_OA_CONTROLLER | DifferentialDryBulb | 1.20 | 5.91 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
CORE_BOTTOM | VAV_BOT WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORE_MID | VAV_MID WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORE_TOP | VAV_TOP WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_3 | VAV_BOT WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_2 | VAV_BOT WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_1 | VAV_BOT WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_4 | VAV_BOT WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_3 | VAV_MID WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_2 | VAV_MID WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_1 | VAV_MID WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_4 | VAV_MID WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_3 | VAV_TOP WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_2 | VAV_TOP WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_1 | VAV_TOP WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_4 | VAV_TOP WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
BASEMENT | 2095.50 | 2449.50 | 414.67 |
CORE_BOTTOM | 2005.17 | 2230.33 | 21.83 |
CORE_MID | 1982.50 | 3484.83 | 472.33 |
CORE_TOP | 2876.17 | 3951.83 | 1538.50 |
PERIMETER_BOT_ZN_3 | 2794.17 | 3698.83 | 1192.00 |
PERIMETER_BOT_ZN_2 | 2815.00 | 3900.33 | 1313.83 |
PERIMETER_BOT_ZN_1 | 2840.50 | 3445.17 | 1085.33 |
PERIMETER_BOT_ZN_4 | 2702.17 | 3209.17 | 671.33 |
PERIMETER_MID_ZN_3 | 3688.00 | 4197.83 | 2440.33 |
PERIMETER_MID_ZN_2 | 3023.17 | 3658.50 | 1991.17 |
PERIMETER_MID_ZN_1 | 3217.83 | 3845.00 | 1734.17 |
PERIMETER_MID_ZN_4 | 3407.00 | 4261.50 | 2107.50 |
PERIMETER_TOP_ZN_3 | 3949.00 | 4541.00 | 2902.00 |
PERIMETER_TOP_ZN_2 | 3866.67 | 4381.00 | 2655.50 |
PERIMETER_TOP_ZN_1 | 3550.50 | 4172.00 | 2246.33 |
PERIMETER_TOP_ZN_4 | 3687.83 | 4468.17 | 2533.83 |
DATACENTER_BOT_ZN_6 | 5693.67 | 812.67 | 806.17 |
DATACENTER_MID_ZN_6 | 4597.83 | 528.83 | 202.67 |
DATACENTER_TOP_ZN_6 | 4087.67 | 971.33 | 345.33 |
DATACENTER_BASEMENT_ZN_6 | 5943.00 | 5491.50 | 5491.50 |
GROUNDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
Facility | 5943.00 | 5943.00 | 5941.17 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
BASEMENT | 0.00 | 40.67 | 0.00 | 2.17 |
CORE_BOTTOM | 0.00 | 3.00 | 0.00 | 2.17 |
CORE_MID | 2.50 | 0.67 | 0.83 | 0.67 |
CORE_TOP | 24.17 | 0.83 | 4.00 | 0.83 |
PERIMETER_BOT_ZN_3 | 8.83 | 4.17 | 1.33 | 4.17 |
PERIMETER_BOT_ZN_2 | 8.83 | 11.67 | 0.50 | 11.67 |
PERIMETER_BOT_ZN_1 | 10.50 | 21.50 | 0.67 | 21.50 |
PERIMETER_BOT_ZN_4 | 2.67 | 53.33 | 0.00 | 20.17 |
PERIMETER_MID_ZN_3 | 231.00 | 3.00 | 87.50 | 3.00 |
PERIMETER_MID_ZN_2 | 120.67 | 11.17 | 21.83 | 11.17 |
PERIMETER_MID_ZN_1 | 83.67 | 21.00 | 9.50 | 21.00 |
PERIMETER_MID_ZN_4 | 84.50 | 18.33 | 14.83 | 9.00 |
PERIMETER_TOP_ZN_3 | 469.83 | 0.00 | 183.17 | 0.00 |
PERIMETER_TOP_ZN_2 | 277.67 | 9.50 | 61.83 | 9.50 |
PERIMETER_TOP_ZN_1 | 242.50 | 13.67 | 50.50 | 13.33 |
PERIMETER_TOP_ZN_4 | 213.00 | 17.83 | 47.00 | 8.67 |
DATACENTER_BOT_ZN_6 | 0.00 | 5.33 | 0.00 | 2.17 |
DATACENTER_MID_ZN_6 | 0.00 | 3.67 | 0.00 | 0.83 |
DATACENTER_TOP_ZN_6 | 0.00 | 2.83 | 0.00 | 0.33 |
DATACENTER_BASEMENT_ZN_6 | 0.00 | 72.83 | 0.00 | 70.50 |
GROUNDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 555.17 | 228.17 | 206.33 | 149.67 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BASEMENT | 60.99 | 149.60 | 6779.02 | 1.184 | 0.000 | 0.000 | 0.000 |
CORE_BOTTOM | 54.77 | 134.35 | 6849.35 | 0.983 | 0.000 | 0.000 | 0.000 |
CORE_MID | 54.77 | 134.35 | 6849.35 | 0.813 | 0.000 | 0.000 | 0.000 |
CORE_TOP | 54.77 | 134.35 | 6849.35 | 0.775 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_3 | 6.88 | 16.87 | 860.00 | 1.004 | 0.045 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_2 | 4.43 | 10.87 | 554.22 | 1.770 | 0.046 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_1 | 6.88 | 16.87 | 860.02 | 1.613 | 0.045 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_4 | 4.43 | 10.87 | 554.22 | 2.264 | 0.046 | 0.000 | 0.000 |
PERIMETER_MID_ZN_3 | 6.88 | 16.87 | 860.00 | 0.897 | 0.104 | 0.000 | 0.000 |
PERIMETER_MID_ZN_2 | 3.86 | 10.87 | 554.22 | 1.776 | 0.114 | 0.000 | 0.000 |
PERIMETER_MID_ZN_1 | 6.88 | 16.87 | 860.02 | 1.637 | 0.104 | 0.000 | 0.000 |
PERIMETER_MID_ZN_4 | 4.43 | 10.87 | 554.22 | 1.950 | 0.108 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_3 | 6.88 | 16.87 | 860.00 | 1.039 | 0.129 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_2 | 4.43 | 10.87 | 554.22 | 1.860 | 0.133 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_1 | 6.88 | 16.87 | 860.02 | 1.643 | 0.129 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_4 | 4.43 | 10.87 | 554.22 | 1.991 | 0.133 | 0.000 | 0.000 |
DATACENTER_BOT_ZN_6 | 0.79 | 1.95 | 99.34 | 0.427 | 0.000 | 0.000 | 0.000 |
DATACENTER_MID_ZN_6 | 0.79 | 1.95 | 99.34 | 0.427 | 0.000 | 0.000 | 0.000 |
DATACENTER_TOP_ZN_6 | 0.79 | 1.95 | 99.34 | 0.426 | 0.000 | 0.000 | 0.000 |
DATACENTER_BASEMENT_ZN_6 | 17.20 | 42.18 | 1911.37 | 0.481 | 0.000 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BASEMENT | 60.99 | 149.60 | 6779.02 | 0.000 | 0.000 | 0.000 | 0.000 |
CORE_BOTTOM | 54.77 | 134.35 | 6849.35 | 0.000 | 0.000 | 0.000 | 0.000 |
CORE_MID | 54.77 | 134.35 | 6849.35 | 0.000 | 0.000 | 0.000 | 0.000 |
CORE_TOP | 54.77 | 134.35 | 6849.35 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_3 | 6.88 | 16.87 | 860.00 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_2 | 4.43 | 10.87 | 554.22 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_1 | 6.88 | 16.87 | 860.02 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_4 | 4.43 | 10.87 | 554.22 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_3 | 6.88 | 16.87 | 860.00 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_2 | 3.86 | 10.87 | 554.22 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_1 | 6.88 | 16.87 | 860.02 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_4 | 4.43 | 10.87 | 554.22 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_3 | 6.88 | 16.87 | 860.00 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_2 | 4.43 | 10.87 | 554.22 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_1 | 6.88 | 16.87 | 860.02 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_4 | 4.43 | 10.87 | 554.22 | 0.000 | 0.000 | 0.000 | 0.000 |
DATACENTER_BOT_ZN_6 | 0.79 | 1.95 | 99.34 | 0.000 | 0.000 | 0.000 | 0.000 |
DATACENTER_MID_ZN_6 | 0.79 | 1.95 | 99.34 | 0.000 | 0.000 | 0.000 | 0.000 |
DATACENTER_TOP_ZN_6 | 0.79 | 1.95 | 99.34 | 0.000 | 0.000 | 0.000 | 0.000 |
DATACENTER_BASEMENT_ZN_6 | 17.20 | 42.18 | 1911.37 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Mechanical Ventilation Parameters by ZoneAirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
BASEMENT | CAV_BAS | 60.99 | 149.60 | 6779.02 | 2779.43 | 1.2002 | 1.200 |
CORE_BOTTOM | VAV_BOT WITH REHEAT | 54.77 | 134.35 | 6849.35 | 2496.12 | 0.0000 | 1.078 |
CORE_MID | VAV_MID WITH REHEAT | 54.77 | 134.35 | 6849.35 | 2496.12 | 0.0000 | 10.778 |
CORE_TOP | VAV_TOP WITH REHEAT | 54.77 | 134.35 | 6849.35 | 2496.12 | 0.0000 | 1.078 |
PERIMETER_BOT_ZN_3 | VAV_BOT WITH REHEAT | 6.88 | 16.87 | 860.00 | 313.41 | 0.0000 | 0.135 |
PERIMETER_BOT_ZN_2 | VAV_BOT WITH REHEAT | 4.43 | 10.87 | 554.22 | 201.98 | 0.0000 | 0.087 |
PERIMETER_BOT_ZN_1 | VAV_BOT WITH REHEAT | 6.88 | 16.87 | 860.02 | 313.42 | 0.0000 | 0.135 |
PERIMETER_BOT_ZN_4 | VAV_BOT WITH REHEAT | 4.43 | 10.87 | 554.22 | 201.98 | 0.0000 | 0.087 |
PERIMETER_MID_ZN_3 | VAV_MID WITH REHEAT | 6.88 | 16.87 | 860.00 | 313.41 | 0.0000 | 1.353 |
PERIMETER_MID_ZN_2 | VAV_MID WITH REHEAT | 3.86 | 10.87 | 554.22 | 201.98 | 0.0000 | 0.872 |
PERIMETER_MID_ZN_1 | VAV_MID WITH REHEAT | 6.88 | 16.87 | 860.02 | 313.42 | 0.0000 | 1.353 |
PERIMETER_MID_ZN_4 | VAV_MID WITH REHEAT | 4.43 | 10.87 | 554.22 | 201.98 | 0.0000 | 0.872 |
PERIMETER_TOP_ZN_3 | VAV_TOP WITH REHEAT | 6.88 | 16.87 | 860.00 | 313.41 | 0.0000 | 0.135 |
PERIMETER_TOP_ZN_2 | VAV_TOP WITH REHEAT | 4.43 | 10.87 | 554.22 | 201.98 | 0.0000 | 0.087 |
PERIMETER_TOP_ZN_1 | VAV_TOP WITH REHEAT | 6.88 | 16.87 | 860.02 | 313.42 | 0.0000 | 0.135 |
PERIMETER_TOP_ZN_4 | VAV_TOP WITH REHEAT | 4.43 | 10.87 | 554.22 | 201.98 | 0.0000 | 0.087 |
DATACENTER_BOT_ZN_6 | AIRLOOP DATACENTER BOT | 0.79 | 1.95 | 99.34 | 36.20 | 0.0156 | 0.016 |
DATACENTER_MID_ZN_6 | AIRLOOP DATACENTER MID | 0.79 | 1.95 | 99.34 | 36.20 | 0.1563 | 0.156 |
DATACENTER_TOP_ZN_6 | AIRLOOP DATACENTER TOP | 0.79 | 1.95 | 99.34 | 36.20 | 0.0156 | 0.016 |
DATACENTER_BASEMENT_ZN_6 | AIRLOOP DATACENTER BASEMENT | 17.20 | 42.18 | 1911.37 | 783.68 | 0.3384 | 0.338 |
Total Facility | 1010.73 | 2493.19 | 126016.35 | 46320.38 | 1.7261 | 158.471 |
Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
BASEMENT | 48706695.66 | 0.00 | 48706695.66 | 0.00 | 48706695.66 | 37848132.68 | 4026.70 | 1457.50 | 3275.79 | 356.29 |
CORE_BOTTOM | 41892361.40 | 0.00 | 41892361.40 | 0.00 | 41892361.40 | 33990283.35 | 3691.57 | 7.74 | 5060.69 | 515.96 |
CORE_MID | 0.34E+09 | 0.00 | 0.34E+09 | 0.00 | 0.34E+09 | 0.34E+09 | 4071.45 | 8.97 | 4679.57 | 505.22 |
CORE_TOP | 31674018.70 | 0.00 | 31674018.70 | 0.00 | 31674018.70 | 33990283.35 | 4139.96 | 7.89 | 4612.15 | 418.78 |
PERIMETER_BOT_ZN_3 | 5418209.13 | 0.00 | 5418209.13 | 431999.69 | 5850208.82 | 4267819.30 | 3959.89 | 76.66 | 4723.45 | 515.96 |
PERIMETER_BOT_ZN_2 | 6248392.56 | 0.00 | 6248392.56 | 287999.59 | 6536392.16 | 2750345.05 | 3493.72 | 3.81 | 5262.47 | 515.96 |
PERIMETER_BOT_ZN_1 | 8731763.29 | 0.00 | 8731763.29 | 431999.69 | 9163762.98 | 4267912.63 | 3527.80 | 4.00 | 5228.20 | 515.96 |
PERIMETER_BOT_ZN_4 | 7962013.23 | 0.00 | 7962013.23 | 287999.59 | 8250012.82 | 2750345.05 | 3463.87 | 4.97 | 5291.16 | 515.96 |
PERIMETER_MID_ZN_3 | 46646509.02 | 0.00 | 46646509.02 | 1013169.02 | 47659678.04 | 42678193.03 | 4066.14 | 13.84 | 4680.02 | 505.22 |
PERIMETER_MID_ZN_2 | 63667081.02 | 0.00 | 63667081.02 | 675445.55 | 64342526.58 | 27503450.52 | 3893.50 | 3.78 | 4862.72 | 1414.22 |
PERIMETER_MID_ZN_1 | 85049613.67 | 0.00 | 85049613.67 | 1013169.02 | 86062782.69 | 42679126.28 | 3940.20 | 3.36 | 4816.44 | 505.22 |
PERIMETER_MID_ZN_4 | 65769454.34 | 0.00 | 65769454.34 | 675445.55 | 66444899.90 | 27503450.52 | 3880.95 | 5.13 | 4873.92 | 505.22 |
PERIMETER_TOP_ZN_3 | 5355773.87 | 0.00 | 5355773.87 | 1257968.18 | 6613742.04 | 4267819.30 | 4079.77 | 2.27 | 4677.96 | 418.78 |
PERIMETER_TOP_ZN_2 | 6172814.64 | 0.00 | 6172814.64 | 838644.88 | 7011459.52 | 2750345.05 | 4024.49 | 3.57 | 4731.94 | 418.78 |
PERIMETER_TOP_ZN_1 | 8437989.02 | 0.00 | 8437989.02 | 1257968.18 | 9695957.20 | 4267912.63 | 4049.19 | 1.51 | 4709.30 | 418.78 |
PERIMETER_TOP_ZN_4 | 6622264.22 | 0.00 | 6622264.22 | 838644.88 | 7460909.09 | 2750345.05 | 4008.46 | 2.58 | 4748.95 | 418.78 |
DATACENTER_BOT_ZN_6 | 244296.02 | 0.00 | 244296.02 | 0.00 | 244296.02 | 492981.60 | 4419.00 | 4341.00 | 0.00 | 0.00 |
DATACENTER_MID_ZN_6 | 2442960.18 | 0.00 | 2442960.18 | 0.00 | 2442960.18 | 4929815.99 | 4419.00 | 4341.00 | 0.00 | 0.00 |
DATACENTER_TOP_ZN_6 | 244296.02 | 0.00 | 244296.02 | 0.00 | 244296.02 | 492981.60 | 4419.00 | 4341.00 | 0.00 | 0.00 |
DATACENTER_BASEMENT_ZN_6 | 5288266.81 | 0.00 | 5288266.81 | 0.00 | 5288266.81 | 10671554.30 | 4419.00 | 4341.00 | 0.00 | 0.00 |
Total Facility | 0.62E+10 | 0.00 | 0.62E+10 | 39405516.14 | 0.62E+10 | 0.50E+10 | 4754.85 | 4398.87 | 5449.34 | 2084.85 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
BASEMENT | 2.1782 | 0.0000 | 2.1782 | 0.0000 | 2.1782 | 1.2002 | 1392.62 | 1454.54 | 3095.84 |
CORE_BOTTOM | 1.8293 | 0.0000 | 1.8293 | 0.0000 | 1.8293 | 1.0778 | 1246.05 | 5.61 | 4691.34 |
CORE_MID | 15.1441 | 0.0000 | 15.1441 | 0.0000 | 15.1441 | 10.7782 | 1378.88 | 8.27 | 4555.85 |
CORE_TOP | 1.4459 | 0.0000 | 1.4459 | 0.0000 | 1.4459 | 1.0778 | 1403.25 | 7.89 | 4531.86 |
PERIMETER_BOT_ZN_3 | 0.2349 | 0.0000 | 0.2349 | 0.0105 | 0.2454 | 0.1353 | 1537.81 | 74.61 | 4330.58 |
PERIMETER_BOT_ZN_2 | 0.2677 | 0.0000 | 0.2677 | 0.0070 | 0.2747 | 0.0872 | 1128.17 | 2.80 | 4812.03 |
PERIMETER_BOT_ZN_1 | 0.3779 | 0.0000 | 0.3779 | 0.0105 | 0.3884 | 0.1353 | 1154.07 | 3.08 | 4785.85 |
PERIMETER_BOT_ZN_4 | 0.3418 | 0.0000 | 0.3418 | 0.0070 | 0.3488 | 0.0872 | 1107.62 | 2.17 | 4833.20 |
PERIMETER_MID_ZN_3 | 2.1036 | 0.0000 | 2.1036 | 0.0246 | 2.1282 | 1.3533 | 1377.49 | 12.94 | 4552.56 |
PERIMETER_MID_ZN_2 | 2.6898 | 0.0000 | 2.6898 | 0.0173 | 2.7071 | 0.8721 | 1243.88 | 1.38 | 3788.74 |
PERIMETER_MID_ZN_1 | 3.8420 | 0.0000 | 3.8420 | 0.0246 | 3.8666 | 1.3533 | 1268.18 | 2.60 | 4672.22 |
PERIMETER_MID_ZN_4 | 2.9533 | 0.0000 | 2.9533 | 0.0164 | 2.9697 | 0.8721 | 1236.33 | 3.08 | 4703.59 |
PERIMETER_TOP_ZN_3 | 0.2442 | 0.0000 | 0.2442 | 0.0305 | 0.2747 | 0.1353 | 1348.24 | 2.21 | 4592.55 |
PERIMETER_TOP_ZN_2 | 0.2816 | 0.0000 | 0.2816 | 0.0204 | 0.3020 | 0.0872 | 1307.98 | 2.40 | 4632.62 |
PERIMETER_TOP_ZN_1 | 0.3857 | 0.0000 | 0.3857 | 0.0305 | 0.4162 | 0.1353 | 1324.69 | 0.72 | 4617.59 |
PERIMETER_TOP_ZN_4 | 0.3016 | 0.0000 | 0.3016 | 0.0204 | 0.3220 | 0.0872 | 1298.55 | 1.29 | 4643.16 |
DATACENTER_BOT_ZN_6 | 0.0114 | 0.0000 | 0.0114 | 0.0000 | 0.0114 | 0.0156 | 1602.00 | 4341.00 | 0.00 |
DATACENTER_MID_ZN_6 | 0.1142 | 0.0000 | 0.1142 | 0.0000 | 0.1142 | 0.1563 | 1602.00 | 4341.00 | 0.00 |
DATACENTER_TOP_ZN_6 | 0.0114 | 0.0000 | 0.0114 | 0.0000 | 0.0114 | 0.0156 | 1602.00 | 4341.00 | 0.00 |
DATACENTER_BASEMENT_ZN_6 | 0.2472 | 0.0000 | 0.2472 | 0.0000 | 0.2472 | 0.3384 | 1602.00 | 4341.00 | 0.00 |
Total Facility | 276.6291 | 0.0000 | 276.6291 | 0.9658 | 277.5948 | 158.4706 | 1937.85 | 4376.99 | 4888.72 |
Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
VAV_BOT WITH REHEAT | 93543172.08 | 0.00 | 93543172.08 | 48026705.38 | 3546.27 | 5.27 | 5208.46 | 515.96 |
VAV_MID WITH REHEAT | 0.80E+09 | 0.00 | 0.80E+09 | 0.48E+09 | 3968.10 | 4.73 | 4787.17 | 505.22 |
VAV_TOP WITH REHEAT | 77579529.32 | 0.00 | 77579529.32 | 48026705.38 | 4061.87 | 1.33 | 4696.80 | 418.56 |
CAV_BAS | 64855038.93 | 0.00 | 64855038.93 | 37848132.68 | 3951.48 | 4.54 | 4803.98 | 356.29 |
AIRLOOP DATACENTER BASEMENT | 7041552.40 | 0.00 | 7041552.40 | 10671554.30 | 4419.00 | 0.00 | 4341.00 | 0.00 |
AIRLOOP DATACENTER BOT | 325290.55 | 0.00 | 325290.55 | 492981.60 | 4419.00 | 0.00 | 4341.00 | 0.00 |
AIRLOOP DATACENTER MID | 3252905.49 | 0.00 | 3252905.49 | 4929815.99 | 4419.00 | 0.00 | 4341.00 | 0.00 |
AIRLOOP DATACENTER TOP | 325290.55 | 0.00 | 325290.55 | 492981.60 | 4419.00 | 0.00 | 4341.00 | 0.00 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
VAV_BOT WITH REHEAT | 4.0635 | 0.0000 | 4.0635 | 1.5229 | 1166.21 | 4.74 | 4772.05 |
VAV_MID WITH REHEAT | 35.8274 | 0.0000 | 35.8274 | 15.2292 | 1289.72 | 3.00 | 4650.27 |
VAV_TOP WITH REHEAT | 3.5405 | 0.0000 | 3.5405 | 1.5229 | 1333.60 | 0.33 | 4609.07 |
CAV_BAS | 2.9003 | 0.0000 | 2.9003 | 1.2002 | 1362.72 | 1.58 | 4578.70 |
AIRLOOP DATACENTER BASEMENT | 0.3291 | 0.0000 | 0.3291 | 0.3384 | 1602.00 | 0.00 | 4341.00 |
AIRLOOP DATACENTER BOT | 0.0152 | 0.0000 | 0.0152 | 0.0156 | 1602.00 | 0.00 | 4341.00 |
AIRLOOP DATACENTER MID | 0.1520 | 0.0000 | 0.1520 | 0.1563 | 1602.00 | 0.00 | 4341.00 |
AIRLOOP DATACENTER TOP | 0.0152 | 0.0000 | 0.0152 | 0.0156 | 1602.00 | 0.00 | 4341.00 |
No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
VAV_BOT WITH REHEAT | 0.00 | 2314.76 | 3087.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
VAV_MID WITH REHEAT | 0.00 | 2604.76 | 2792.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
VAV_TOP WITH REHEAT | 0.00 | 2746.78 | 2550.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CAV_BAS | 0.00 | 1433.11 | 3578.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
AIRLOOP DATACENTER BASEMENT | 0.00 | 4341.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
AIRLOOP DATACENTER BOT | 0.00 | 4341.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
AIRLOOP DATACENTER MID | 0.00 | 4341.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
AIRLOOP DATACENTER TOP | 0.00 | 4341.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
VAV_BOT WITH REHEAT | 0.0000 | 3.3839 | 6.3448 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
VAV_MID WITH REHEAT | 0.0000 | 33.9077 | 54.4936 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
VAV_TOP WITH REHEAT | 0.0000 | 3.3822 | 5.5157 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
CAV_BAS | 0.0000 | 1.5982 | 4.6389 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
AIRLOOP DATACENTER BASEMENT | 0.0000 | 0.4507 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
AIRLOOP DATACENTER BOT | 0.0000 | 0.0208 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
AIRLOOP DATACENTER MID | 0.0000 | 0.2082 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
AIRLOOP DATACENTER TOP | 0.0000 | 0.0208 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Surfaces by ClassTotal | Outdoors | |
Wall | 98 | 30 |
Floor | 41 | 0 |
Roof | 30 | 1 |
Internal Mass | 16 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 24 | 24 |
Door | 12 | 12 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 8 |
Conditioned Zones | 23 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 3 |
Count | |
IDF Objects | 1388 |
Defaulted Fields | 1179 |
Fields with Defaults | 3942 |
Autosized Fields | 337 |
Autosizable Fields | 413 |
Autocalculated Fields | 226 |
Autocalculatable Fields | 473 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 28302.01 | 365417.68 | 01-JAN-10:40 | 2059095.48 | 08-AUG-15:20 |
Electricity:Building | 18923.50 | 251811.03 | 01-JAN-09:40 | 1146857.44 | 01-DEC-16:20 |
Electricity:Zone:BASEMENT | 664.85 | 14623.97 | 01-JAN-00:10 | 34452.17 | 02-JAN-08:10 |
Electricity:SpaceType:GENERAL | 18923.50 | 251811.03 | 01-JAN-09:40 | 1146857.44 | 01-DEC-16:20 |
InteriorLights:Electricity | 3710.09 | 17601.77 | 01-JAN-09:40 | 352853.36 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:BASEMENT | 240.45 | 1166.43 | 01-JAN-00:10 | 20994.62 | 02-JAN-08:10 |
InteriorLights:Electricity:SpaceType:GENERAL | 3710.09 | 17601.77 | 01-JAN-09:40 | 352853.36 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity | 3710.09 | 17601.77 | 01-JAN-09:40 | 352853.36 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:BASEMENT | 240.45 | 1166.43 | 01-JAN-00:10 | 20994.62 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 3710.09 | 17601.77 | 01-JAN-09:40 | 352853.36 | 02-JAN-08:10 |
Electricity:Zone:CORE_BOTTOM | 537.23 | 7090.40 | 01-JAN-00:10 | 36983.24 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_BOTTOM | 215.94 | 1047.53 | 01-JAN-00:10 | 18854.65 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_BOTTOM | 215.94 | 1047.53 | 01-JAN-00:10 | 18854.65 | 02-JAN-08:10 |
Electricity:Zone:CORE_MID | 5372.24 | 70903.72 | 01-JAN-00:10 | 369831.68 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_MID | 2159.40 | 10475.32 | 01-JAN-00:10 | 188546.48 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_MID | 2159.40 | 10475.32 | 01-JAN-00:10 | 188546.48 | 02-JAN-08:10 |
Electricity:Zone:CORE_TOP | 537.22 | 7090.37 | 01-JAN-00:10 | 36983.17 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_TOP | 215.94 | 1047.53 | 01-JAN-00:10 | 18854.65 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_TOP | 215.94 | 1047.53 | 01-JAN-00:10 | 18854.65 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_BOT_ZN_3 | 59.12 | 839.57 | 01-JAN-09:30 | 4643.71 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_3 | 18.78 | 80.80 | 01-JAN-09:30 | 2367.39 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_3 | 18.78 | 80.80 | 01-JAN-09:30 | 2367.39 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_BOT_ZN_2 | 38.07 | 541.05 | 01-JAN-08:40 | 2992.58 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_2 | 12.07 | 52.07 | 01-JAN-08:40 | 1525.64 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_2 | 12.07 | 52.07 | 01-JAN-08:40 | 1525.64 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_BOT_ZN_1 | 58.99 | 839.58 | 01-JAN-08:40 | 4643.79 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_1 | 18.64 | 80.80 | 01-JAN-08:40 | 2367.44 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_1 | 18.64 | 80.80 | 01-JAN-08:40 | 2367.44 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_BOT_ZN_4 | 38.05 | 541.05 | 01-JAN-09:30 | 2992.57 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_4 | 12.05 | 52.07 | 01-JAN-09:30 | 1525.64 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_4 | 12.05 | 52.07 | 01-JAN-09:30 | 1525.64 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_MID_ZN_3 | 591.42 | 8395.70 | 01-JAN-09:40 | 46437.07 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_3 | 188.00 | 807.98 | 01-JAN-09:40 | 23673.89 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_3 | 188.00 | 807.98 | 01-JAN-09:40 | 23673.89 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_MID_ZN_2 | 380.74 | 5410.51 | 01-JAN-08:40 | 29925.82 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_2 | 120.76 | 520.69 | 01-JAN-08:40 | 15256.36 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_2 | 120.76 | 520.69 | 01-JAN-08:40 | 15256.36 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_MID_ZN_1 | 589.98 | 8395.84 | 01-JAN-08:40 | 46437.94 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_1 | 186.55 | 807.99 | 01-JAN-08:40 | 23674.41 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_1 | 186.55 | 807.99 | 01-JAN-08:40 | 23674.41 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_MID_ZN_4 | 380.53 | 5410.48 | 01-JAN-09:40 | 29925.72 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_4 | 120.55 | 520.69 | 01-JAN-09:40 | 15256.36 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_4 | 120.55 | 520.69 | 01-JAN-09:40 | 15256.36 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_TOP_ZN_3 | 59.14 | 839.57 | 01-JAN-09:40 | 4643.71 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_3 | 18.80 | 80.80 | 01-JAN-09:40 | 2367.39 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_3 | 18.80 | 80.80 | 01-JAN-09:40 | 2367.39 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_TOP_ZN_2 | 38.07 | 541.05 | 01-JAN-08:40 | 2992.58 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_2 | 12.08 | 52.07 | 01-JAN-08:40 | 1525.64 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_2 | 12.08 | 52.07 | 01-JAN-08:40 | 1525.64 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_TOP_ZN_1 | 59.00 | 839.58 | 01-JAN-08:40 | 4643.79 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_1 | 18.65 | 80.80 | 01-JAN-08:40 | 2367.44 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_1 | 18.65 | 80.80 | 01-JAN-08:40 | 2367.44 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_TOP_ZN_4 | 38.05 | 541.05 | 01-JAN-09:40 | 2992.57 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_4 | 12.06 | 52.07 | 01-JAN-09:40 | 1525.64 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_4 | 12.06 | 52.07 | 01-JAN-09:40 | 1525.64 | 02-JAN-08:10 |
Electricity:Zone:DATACENTER_BASEMENT_ZN_6 | 7562.65 | 95237.01 | 01-JAN-00:10 | 385552.11 | 03-APR-07:10 |
InteriorLights:Electricity:Zone:DATACENTER_BASEMENT_ZN_6 | 67.80 | 328.88 | 01-JAN-00:10 | 5919.59 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:DATACENTER_BASEMENT_ZN_6 | 67.80 | 328.88 | 01-JAN-00:10 | 5919.59 | 02-JAN-08:10 |
Electricity:Zone:DATACENTER_BOT_ZN_6 | 159.85 | 1977.54 | 01-JAN-00:10 | 8315.27 | 03-APR-07:10 |
InteriorLights:Electricity:Zone:DATACENTER_BOT_ZN_6 | 5.97 | 28.94 | 01-JAN-00:10 | 520.85 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:DATACENTER_BOT_ZN_6 | 5.97 | 28.94 | 01-JAN-00:10 | 520.85 | 02-JAN-08:10 |
Electricity:Zone:DATACENTER_MID_ZN_6 | 1598.46 | 19775.43 | 01-JAN-00:10 | 83152.69 | 03-APR-07:10 |
InteriorLights:Electricity:Zone:DATACENTER_MID_ZN_6 | 59.65 | 289.38 | 01-JAN-00:10 | 5208.47 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:DATACENTER_MID_ZN_6 | 59.65 | 289.38 | 01-JAN-00:10 | 5208.47 | 02-JAN-08:10 |
Electricity:Zone:DATACENTER_TOP_ZN_6 | 159.85 | 1977.54 | 01-JAN-00:10 | 8315.27 | 03-APR-07:10 |
InteriorLights:Electricity:Zone:DATACENTER_TOP_ZN_6 | 5.97 | 28.94 | 01-JAN-00:10 | 520.85 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:DATACENTER_TOP_ZN_6 | 5.97 | 28.94 | 01-JAN-00:10 | 520.85 | 02-JAN-08:10 |
InteriorEquipment:Electricity | 15213.41 | 234209.26 | 01-JAN-00:10 | 794004.08 | 03-APR-07:10 |
InteriorEquipment:Electricity:Zone:BASEMENT | 424.40 | 13457.54 | 01-JAN-00:10 | 13457.54 | 01-JAN-00:10 |
InteriorEquipment:Electricity:SpaceType:GENERAL | 15213.41 | 234209.26 | 01-JAN-00:10 | 794004.08 | 03-APR-07:10 |
MiscPlug:InteriorEquipment:Electricity | 5871.99 | 115917.86 | 01-JAN-00:10 | 320838.49 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:BASEMENT | 424.40 | 13457.54 | 01-JAN-00:10 | 13457.54 | 01-JAN-00:10 |
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 5871.99 | 115917.86 | 01-JAN-00:10 | 320838.49 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 321.29 | 6042.86 | 01-JAN-00:10 | 18128.59 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 321.29 | 6042.86 | 01-JAN-00:10 | 18128.59 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_MID | 3212.85 | 60428.40 | 01-JAN-00:10 | 181285.20 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_MID | 3212.85 | 60428.40 | 01-JAN-00:10 | 181285.20 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_TOP | 321.28 | 6042.84 | 01-JAN-00:10 | 18128.52 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_TOP | 321.28 | 6042.84 | 01-JAN-00:10 | 18128.52 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_3 | 40.34 | 758.77 | 01-JAN-00:10 | 2276.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_3 | 40.34 | 758.77 | 01-JAN-00:10 | 2276.32 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_2 | 26.00 | 488.98 | 01-JAN-00:10 | 1466.95 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_2 | 26.00 | 488.98 | 01-JAN-00:10 | 1466.95 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_1 | 40.34 | 758.78 | 01-JAN-00:10 | 2276.35 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_1 | 40.34 | 758.78 | 01-JAN-00:10 | 2276.35 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_4 | 26.00 | 488.98 | 01-JAN-00:10 | 1466.94 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_4 | 26.00 | 488.98 | 01-JAN-00:10 | 1466.94 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_3 | 403.42 | 7587.73 | 01-JAN-00:10 | 22763.18 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_3 | 403.42 | 7587.73 | 01-JAN-00:10 | 22763.18 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_2 | 259.98 | 4889.82 | 01-JAN-00:10 | 14669.46 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_2 | 259.98 | 4889.82 | 01-JAN-00:10 | 14669.46 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_1 | 403.43 | 7587.84 | 01-JAN-00:10 | 22763.53 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_1 | 403.43 | 7587.84 | 01-JAN-00:10 | 22763.53 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_4 | 259.98 | 4889.79 | 01-JAN-00:10 | 14669.36 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_4 | 259.98 | 4889.79 | 01-JAN-00:10 | 14669.36 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_3 | 40.34 | 758.77 | 01-JAN-00:10 | 2276.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_3 | 40.34 | 758.77 | 01-JAN-00:10 | 2276.32 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_2 | 26.00 | 488.98 | 01-JAN-00:10 | 1466.95 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_2 | 26.00 | 488.98 | 01-JAN-00:10 | 1466.95 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_1 | 40.34 | 758.78 | 01-JAN-00:10 | 2276.35 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_1 | 40.34 | 758.78 | 01-JAN-00:10 | 2276.35 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_4 | 26.00 | 488.98 | 01-JAN-00:10 | 1466.94 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_4 | 26.00 | 488.98 | 01-JAN-00:10 | 1466.94 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:DATACENTER_BASEMENT_ZN_6 | 7494.86 | 94908.13 | 01-JAN-00:10 | 379632.52 | 31-MAR-23:10 |
DataCenterPlugLoads:InteriorEquipment:Electricity | 9341.42 | 118291.40 | 01-JAN-00:10 | 473165.59 | 31-MAR-23:10 |
DataCenterPlugLoads:InteriorEquipment:Electricity:Zone:DATACENTER_BASEMENT_ZN_6 | 7494.86 | 94908.13 | 01-JAN-00:10 | 379632.52 | 31-MAR-23:10 |
DataCenterPlugLoads:InteriorEquipment:Electricity:SpaceType:GENERAL | 9341.42 | 118291.40 | 01-JAN-00:10 | 473165.59 | 31-MAR-23:10 |
InteriorEquipment:Electricity:Zone:DATACENTER_BOT_ZN_6 | 153.88 | 1948.61 | 01-JAN-00:10 | 7794.42 | 31-MAR-23:10 |
DataCenterPlugLoads:InteriorEquipment:Electricity:Zone:DATACENTER_BOT_ZN_6 | 153.88 | 1948.61 | 01-JAN-00:10 | 7794.42 | 31-MAR-23:10 |
InteriorEquipment:Electricity:Zone:DATACENTER_MID_ZN_6 | 1538.81 | 19486.06 | 01-JAN-00:10 | 77944.22 | 31-MAR-23:10 |
DataCenterPlugLoads:InteriorEquipment:Electricity:Zone:DATACENTER_MID_ZN_6 | 1538.81 | 19486.06 | 01-JAN-00:10 | 77944.22 | 31-MAR-23:10 |
InteriorEquipment:Electricity:Zone:DATACENTER_TOP_ZN_6 | 153.88 | 1948.61 | 01-JAN-00:10 | 7794.42 | 31-MAR-23:10 |
DataCenterPlugLoads:InteriorEquipment:Electricity:Zone:DATACENTER_TOP_ZN_6 | 153.88 | 1948.61 | 01-JAN-00:10 | 7794.42 | 31-MAR-23:10 |
Electricity:Plant | 1782.56 | 4783.12 | 06-JAN-00:40 | 544532.58 | 05-JUL-10:20 |
HeatRejection:Electricity | 722.15 | 1034.51 | 06-JAN-08:00 | 87722.25 | 16-MAY-12:10 |
General:HeatRejection:Electricity | 722.15 | 1034.51 | 06-JAN-08:00 | 87722.25 | 16-MAY-12:10 |
Electricity:HVAC | 5068.52 | 74554.93 | 01-JAN-10:00 | 459750.10 | 08-AUG-15:20 |
ExteriorEquipment:Electricity | 1941.94 | 28795.69 | 01-JAN-00:10 | 118959.22 | 02-JAN-08:20 |
Transformer:ExteriorEquipment:Electricity | 87.33 | 1613.62 | 01-JAN-00:10 | 5481.25 | 01-DEC-16:30 |
ElectricityPurchased:Facility | 28302.01 | 365417.68 | 01-JAN-10:40 | 2059095.48 | 08-AUG-15:20 |
ElectricityPurchased:Plant | 28302.01 | 365417.68 | 01-JAN-10:40 | 2059095.48 | 08-AUG-15:20 |
Cogeneration:ElectricityPurchased | 28302.01 | 365417.68 | 01-JAN-10:40 | 2059095.48 | 08-AUG-15:20 |
General:Cogeneration:ElectricityPurchased | 28302.01 | 365417.68 | 01-JAN-10:40 | 2059095.48 | 08-AUG-15:20 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 28302.01 | 365417.68 | 01-JAN-10:40 | 2059095.48 | 08-AUG-15:20 |
ElectricityNet:Plant | 28302.01 | 365417.68 | 01-JAN-10:40 | 2059095.48 | 08-AUG-15:20 |
Cogeneration:ElectricityNet | 28302.01 | 365417.68 | 01-JAN-10:40 | 2059095.48 | 08-AUG-15:20 |
General:Cogeneration:ElectricityNet | 28302.01 | 365417.68 | 01-JAN-10:40 | 2059095.48 | 08-AUG-15:20 |
Fans:Electricity | 2507.30 | 43538.47 | 18-DEC-22:10 | 313629.03 | 05-JUL-10:50 |
General:Fans:Electricity | 2507.30 | 43538.47 | 18-DEC-22:10 | 313629.03 | 05-JUL-10:50 |
ExteriorLights:Electricity | 672.82 | 0.00 | 01-JAN-08:20 | 54335.80 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 672.82 | 0.00 | 01-JAN-08:20 | 54335.80 | 01-JAN-06:10 |
ElevatorLift:ExteriorEquipment:Electricity | 1848.78 | 27144.47 | 01-JAN-00:10 | 113101.96 | 01-JAN-07:10 |
ElevatorLightsFan:ExteriorEquipment:Electricity | 5.83 | 37.60 | 01-JAN-00:10 | 376.00 | 01-JAN-07:10 |
HeatRecovery:Electricity | 56.32 | 0.00 | 01-JAN-00:10 | 6524.59 | 02-JAN-07:10 |
General:HeatRecovery:Electricity | 56.32 | 0.00 | 01-JAN-00:10 | 6524.59 | 02-JAN-07:10 |
Cooling:Electricity | 2944.32 | 25111.22 | 09-JAN-07:10 | 505731.89 | 05-JUL-10:20 |
General:Cooling:Electricity | 2944.32 | 25111.22 | 09-JAN-07:10 | 505731.89 | 05-JUL-10:20 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Humidifier:Electricity | 31.19 | 0.00 | 01-JAN-00:10 | 6736.07 | 01-FEB-22:00 |
General:Humidifier:Electricity | 31.19 | 0.00 | 01-JAN-00:10 | 6736.07 | 01-FEB-22:00 |
Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Pumps:Electricity | 502.48 | 3456.54 | 02-JAN-00:40 | 81784.50 | 05-JUL-10:40 |
General:Pumps:Electricity | 502.48 | 3456.54 | 02-JAN-00:40 | 81784.50 | 05-JUL-10:40 |
WIRED_LTG_ELECTRICITY | 104.25 | 0.00 | 01-JAN-00:10 | 9915.18 | 02-JAN-08:20 |
WIRED_INT_EQUIP | 5871.99 | 115917.86 | 04-MAR-00:10 | 320838.49 | 03-APR-07:10 |
Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
NaturalGas:Facility | 4711.62 | 5695.87 | 03-JAN-05:40 | 3383004.62 | 09-JAN-07:10 |
NaturalGas:Plant | 4711.62 | 5695.87 | 03-JAN-05:40 | 3383004.62 | 09-JAN-07:10 |
Heating:NaturalGas | 3895.57 | 0.00 | 01-JAN-10:00 | 3353627.48 | 09-JAN-07:10 |
Boiler:Heating:NaturalGas | 3895.57 | 0.00 | 01-JAN-10:00 | 3353627.48 | 09-JAN-07:10 |
WaterSystems:NaturalGas | 816.05 | 5695.87 | 01-JAN-06:00 | 87558.57 | 23-FEB-12:50 |
Water Heater:WaterSystems:NaturalGas | 816.05 | 5695.87 | 01-JAN-06:00 | 87558.57 | 23-FEB-12:50 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopCoolingDemand:Facility | 15957.91 | 122348.23 | 09-JAN-07:10 | 3529819.58 | 05-JUL-10:40 |
PlantLoopCoolingDemand:HVAC | 15957.91 | 122348.23 | 09-JAN-07:10 | 3529819.58 | 05-JUL-10:40 |
CoolingCoils:PlantLoopCoolingDemand | 15957.91 | 122348.23 | 09-JAN-07:10 | 3529819.58 | 05-JUL-10:40 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 5140.50 | 0.00 | 01-JAN-00:10 | 0.00 | 18-MAY-15:10 |
Water:HVAC | 11.60 | 0.00 | 01-JAN-00:10 | 0.00 | 01-FEB-22:00 |
Humidifier:Water | 11.60 | 0.00 | 01-JAN-00:10 | 0.00 | 01-FEB-22:00 |
General:Humidifier:Water | 11.60 | 0.00 | 01-JAN-00:10 | 0.00 | 01-FEB-22:00 |
MainsWater:Facility | 5140.50 | 0.00 | 01-JAN-00:10 | 0.00 | 18-MAY-15:10 |
MainsWater:HVAC | 11.60 | 0.00 | 01-JAN-00:10 | 0.00 | 01-FEB-22:00 |
Humidifier:MainsWater | 11.60 | 0.00 | 01-JAN-00:10 | 0.00 | 01-FEB-22:00 |
General:Humidifier:MainsWater | 11.60 | 0.00 | 01-JAN-00:10 | 0.00 | 01-FEB-22:00 |
Water:Plant | 5128.90 | 0.00 | 01-JAN-00:10 | 0.00 | 18-MAY-15:10 |
WaterSystems:Water | 2280.17 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterUse:WaterSystems:Water | 2280.17 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Plant | 5128.90 | 0.00 | 01-JAN-00:10 | 0.00 | 18-MAY-15:10 |
WaterSystems:MainsWater | 2280.17 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterUse:WaterSystems:MainsWater | 2280.17 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
HeatRejection:Water | 2848.73 | 0.00 | 01-JAN-00:10 | 0.00 | 18-MAY-15:10 |
General:HeatRejection:Water | 2848.73 | 0.00 | 01-JAN-00:10 | 0.00 | 18-MAY-15:10 |
HeatRejection:MainsWater | 2848.73 | 0.00 | 01-JAN-00:10 | 0.00 | 18-MAY-15:10 |
General:HeatRejection:MainsWater | 2848.73 | 0.00 | 01-JAN-00:10 | 0.00 | 18-MAY-15:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
EnergyTransfer:Facility | 55967.62 | 206728.34 | 02-JAN-04:40 | 13205071.42 | 05-JUL-10:40 |
EnergyTransfer:Building | 19064.40 | 88040.09 | 01-JAN-15:20 | 1876229.86 | 26-DEC-06:10 |
EnergyTransfer:Zone:BASEMENT | 641.50 | 0.00 | 01-JAN-00:10 | 69528.91 | 05-SEP-05:10 |
Heating:EnergyTransfer | 1499.37 | 0.00 | 01-FEB-00:50 | 1565379.97 | 02-JAN-05:10 |
Heating:EnergyTransfer:Zone:BASEMENT | 3.02 | 0.00 | 01-JAN-00:10 | 16218.48 | 29-JUL-16:10 |
General:Heating:EnergyTransfer | 1499.37 | 0.00 | 01-FEB-00:50 | 1565379.97 | 02-JAN-05:10 |
General:Heating:EnergyTransfer:Zone:BASEMENT | 3.02 | 0.00 | 01-JAN-00:10 | 16218.48 | 29-JUL-16:10 |
Cooling:EnergyTransfer | 17565.03 | 81390.27 | 01-JAN-10:00 | 1638313.45 | 08-AUG-15:20 |
Cooling:EnergyTransfer:Zone:BASEMENT | 638.47 | 0.00 | 01-JAN-00:10 | 69528.91 | 05-SEP-05:10 |
General:Cooling:EnergyTransfer | 17565.03 | 81390.27 | 01-JAN-10:00 | 1638313.45 | 08-AUG-15:20 |
General:Cooling:EnergyTransfer:Zone:BASEMENT | 638.47 | 0.00 | 01-JAN-00:10 | 69528.91 | 05-SEP-05:10 |
EnergyTransfer:Zone:CORE_BOTTOM | 586.86 | 0.00 | 01-JAN-00:10 | 55288.43 | 05-JUL-15:30 |
Heating:EnergyTransfer:Zone:CORE_BOTTOM | 0.00 | 0.00 | 01-JAN-00:10 | 4748.87 | 02-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:CORE_BOTTOM | 0.00 | 0.00 | 01-JAN-00:10 | 4748.87 | 02-JAN-06:10 |
Cooling:EnergyTransfer:Zone:CORE_BOTTOM | 586.86 | 0.00 | 01-JAN-00:10 | 55288.43 | 05-JUL-15:30 |
General:Cooling:EnergyTransfer:Zone:CORE_BOTTOM | 586.86 | 0.00 | 01-JAN-00:10 | 55288.43 | 05-JUL-15:30 |
EnergyTransfer:Zone:CORE_MID | 4229.76 | 0.00 | 01-JAN-00:40 | 538938.44 | 02-JAN-05:10 |
Heating:EnergyTransfer:Zone:CORE_MID | 26.77 | 0.00 | 01-JAN-00:20 | 538938.44 | 02-JAN-05:10 |
General:Heating:EnergyTransfer:Zone:CORE_MID | 26.77 | 0.00 | 01-JAN-00:20 | 538938.44 | 02-JAN-05:10 |
Cooling:EnergyTransfer:Zone:CORE_MID | 4202.99 | 0.00 | 01-JAN-00:40 | 471965.91 | 05-JUL-15:20 |
General:Cooling:EnergyTransfer:Zone:CORE_MID | 4202.99 | 0.00 | 01-JAN-00:40 | 471965.91 | 05-JUL-15:20 |
EnergyTransfer:Zone:CORE_TOP | 381.62 | 0.00 | 01-JAN-00:40 | 71815.38 | 09-JAN-05:10 |
Heating:EnergyTransfer:Zone:CORE_TOP | 32.26 | 0.00 | 01-JAN-00:40 | 71815.38 | 09-JAN-05:10 |
General:Heating:EnergyTransfer:Zone:CORE_TOP | 32.26 | 0.00 | 01-JAN-00:40 | 71815.38 | 09-JAN-05:10 |
Cooling:EnergyTransfer:Zone:CORE_TOP | 349.36 | 0.00 | 01-JAN-00:20 | 53336.33 | 05-JUL-15:20 |
General:Cooling:EnergyTransfer:Zone:CORE_TOP | 349.36 | 0.00 | 01-JAN-00:20 | 53336.33 | 05-JUL-15:20 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 66.84 | 0.00 | 01-JAN-00:10 | 11716.32 | 09-JAN-05:10 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 4.62 | 0.00 | 01-JAN-00:10 | 11716.32 | 09-JAN-05:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 4.62 | 0.00 | 01-JAN-00:10 | 11716.32 | 09-JAN-05:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 62.22 | 0.00 | 01-JAN-00:10 | 10174.53 | 05-JUL-15:30 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 62.22 | 0.00 | 01-JAN-00:10 | 10174.53 | 05-JUL-15:30 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 67.79 | 0.00 | 01-JAN-00:10 | 13802.01 | 31-JUL-08:10 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 3.30 | 0.00 | 01-JAN-00:10 | 9166.81 | 09-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 3.30 | 0.00 | 01-JAN-00:10 | 9166.81 | 09-JAN-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 64.49 | 0.00 | 01-JAN-00:10 | 13802.01 | 31-JUL-08:10 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 64.49 | 0.00 | 01-JAN-00:10 | 13802.01 | 31-JUL-08:10 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 107.16 | 0.00 | 01-JAN-00:10 | 21176.33 | 01-SEP-13:20 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 4.39 | 0.00 | 01-JAN-00:10 | 15073.25 | 09-JAN-05:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 4.39 | 0.00 | 01-JAN-00:10 | 15073.25 | 09-JAN-05:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 102.78 | 0.00 | 01-JAN-00:10 | 21176.33 | 01-SEP-13:20 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 102.78 | 0.00 | 01-JAN-00:10 | 21176.33 | 01-SEP-13:20 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 97.87 | 0.00 | 01-JAN-00:10 | 16986.16 | 11-AUG-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 0.78 | 0.00 | 01-JAN-00:10 | 6996.52 | 09-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 0.78 | 0.00 | 01-JAN-00:10 | 6996.52 | 09-JAN-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 97.09 | 0.00 | 01-JAN-00:10 | 16986.16 | 11-AUG-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 97.09 | 0.00 | 01-JAN-00:10 | 16986.16 | 11-AUG-16:00 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 725.95 | 0.00 | 01-JAN-00:40 | 129759.54 | 01-JAN-13:30 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 323.55 | 0.00 | 01-JAN-00:40 | 129759.54 | 01-JAN-13:30 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 323.55 | 0.00 | 01-JAN-00:40 | 129759.54 | 01-JAN-13:30 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 402.40 | 0.00 | 01-JAN-00:10 | 98229.69 | 29-JUN-15:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 402.40 | 0.00 | 01-JAN-00:10 | 98229.69 | 29-JUN-15:00 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 694.18 | 0.00 | 01-JAN-00:40 | 156191.43 | 04-JAN-05:10 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 188.55 | 0.00 | 01-JAN-00:40 | 156191.43 | 04-JAN-05:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 188.55 | 0.00 | 01-JAN-00:40 | 156191.43 | 04-JAN-05:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 505.63 | 0.00 | 01-JAN-00:10 | 146411.61 | 24-JUL-08:50 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 505.63 | 0.00 | 01-JAN-00:10 | 146411.61 | 24-JUL-08:50 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 1039.07 | 0.00 | 01-JAN-00:40 | 220808.39 | 01-SEP-13:20 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 185.71 | 0.00 | 01-JAN-00:40 | 206575.15 | 04-JAN-05:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 185.71 | 0.00 | 01-JAN-00:40 | 206575.15 | 04-JAN-05:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 853.36 | 0.00 | 01-JAN-00:20 | 220808.39 | 01-SEP-13:20 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 853.36 | 0.00 | 01-JAN-00:20 | 220808.39 | 01-SEP-13:20 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 699.44 | 0.00 | 01-JAN-00:40 | 160065.65 | 30-JUN-17:00 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 151.12 | 0.00 | 01-JAN-00:40 | 154153.88 | 04-JAN-05:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 151.12 | 0.00 | 01-JAN-00:40 | 154153.88 | 04-JAN-05:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 548.32 | 0.00 | 01-JAN-00:20 | 160065.65 | 30-JUN-17:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 548.32 | 0.00 | 01-JAN-00:20 | 160065.65 | 30-JUN-17:00 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 104.86 | 0.00 | 01-JAN-00:40 | 17656.91 | 09-JAN-04:20 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 67.43 | 0.00 | 01-JAN-00:40 | 17656.91 | 09-JAN-04:20 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 67.43 | 0.00 | 01-JAN-00:40 | 17656.91 | 09-JAN-04:20 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 37.42 | 0.00 | 01-JAN-00:10 | 10689.90 | 29-JUN-15:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 37.42 | 0.00 | 01-JAN-00:10 | 10689.90 | 29-JUN-15:00 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 84.69 | 0.00 | 01-JAN-00:40 | 17722.87 | 04-JAN-05:10 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 39.49 | 0.00 | 01-JAN-00:40 | 17722.87 | 04-JAN-05:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 39.49 | 0.00 | 01-JAN-00:40 | 17722.87 | 04-JAN-05:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 45.20 | 0.00 | 01-JAN-00:10 | 14790.99 | 24-JUL-08:50 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 45.20 | 0.00 | 01-JAN-00:10 | 14790.99 | 24-JUL-08:50 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 120.18 | 0.00 | 01-JAN-00:40 | 23772.12 | 13-FEB-04:10 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 44.89 | 0.00 | 01-JAN-00:40 | 23772.12 | 13-FEB-04:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 44.89 | 0.00 | 01-JAN-00:40 | 23772.12 | 13-FEB-04:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 75.29 | 0.00 | 01-JAN-00:10 | 23064.98 | 01-SEP-13:20 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 75.29 | 0.00 | 01-JAN-00:10 | 23064.98 | 01-SEP-13:20 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 82.39 | 0.00 | 01-JAN-00:40 | 18953.60 | 04-JAN-05:10 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 32.87 | 0.00 | 01-JAN-00:40 | 18953.60 | 04-JAN-05:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 32.87 | 0.00 | 01-JAN-00:40 | 18953.60 | 04-JAN-05:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 49.53 | 0.00 | 01-JAN-00:10 | 16736.36 | 30-JUN-17:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 49.53 | 0.00 | 01-JAN-00:10 | 16736.36 | 30-JUN-17:00 |
EnergyTransfer:Zone:GROUNDFLOOR_PLENUM | 59.44 | 0.00 | 01-JAN-00:10 | 9490.00 | 02-JAN-06:20 |
Heating:EnergyTransfer:Zone:GROUNDFLOOR_PLENUM | 9.59 | 0.00 | 01-JAN-00:10 | 9490.00 | 02-JAN-06:20 |
General:Heating:EnergyTransfer:Zone:GROUNDFLOOR_PLENUM | 9.59 | 0.00 | 01-JAN-00:10 | 9490.00 | 02-JAN-06:20 |
Cooling:EnergyTransfer:Zone:GROUNDFLOOR_PLENUM | 49.85 | 0.00 | 01-JAN-00:10 | 9287.11 | 24-JUL-15:20 |
General:Cooling:EnergyTransfer:Zone:GROUNDFLOOR_PLENUM | 49.85 | 0.00 | 01-JAN-00:10 | 9287.11 | 24-JUL-15:20 |
EnergyTransfer:Zone:MIDFLOOR_PLENUM | 619.24 | 0.00 | 01-JAN-00:40 | 220265.56 | 02-JAN-06:20 |
Heating:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 272.64 | 0.00 | 01-JAN-00:40 | 220265.56 | 02-JAN-06:20 |
General:Heating:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 272.64 | 0.00 | 01-JAN-00:40 | 220265.56 | 02-JAN-06:20 |
Cooling:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 346.60 | 0.00 | 01-JAN-00:10 | 78103.87 | 30-JUN-16:00 |
General:Cooling:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 346.60 | 0.00 | 01-JAN-00:10 | 78103.87 | 30-JUN-16:00 |
EnergyTransfer:Zone:TOPFLOOR_PLENUM | 141.18 | 0.00 | 01-JAN-00:40 | 35036.43 | 09-JAN-05:20 |
Heating:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 99.98 | 0.00 | 01-JAN-00:40 | 35036.43 | 09-JAN-05:20 |
General:Heating:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 99.98 | 0.00 | 01-JAN-00:40 | 35036.43 | 09-JAN-05:20 |
Cooling:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 41.20 | 0.00 | 01-JAN-00:10 | 19784.66 | 30-JUN-14:50 |
General:Cooling:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 41.20 | 0.00 | 01-JAN-00:10 | 19784.66 | 30-JUN-14:50 |
EnergyTransfer:Zone:DATACENTER_BOT_ZN_6 | 133.67 | 5.17 | 06-JAN-07:00 | 8474.57 | 21-APR-18:10 |
Heating:EnergyTransfer:Zone:DATACENTER_BOT_ZN_6 | 0.10 | 0.00 | 01-JAN-15:50 | 600.81 | 01-JAN-19:50 |
General:Heating:EnergyTransfer:Zone:DATACENTER_BOT_ZN_6 | 0.10 | 0.00 | 01-JAN-15:50 | 600.81 | 01-JAN-19:50 |
Cooling:EnergyTransfer:Zone:DATACENTER_BOT_ZN_6 | 133.56 | 0.00 | 01-JAN-00:10 | 8474.57 | 21-APR-18:10 |
General:Cooling:EnergyTransfer:Zone:DATACENTER_BOT_ZN_6 | 133.56 | 0.00 | 01-JAN-00:10 | 8474.57 | 21-APR-18:10 |
EnergyTransfer:Zone:DATACENTER_MID_ZN_6 | 1127.48 | 20.17 | 19-JAN-22:40 | 80680.95 | 21-APR-18:10 |
Heating:EnergyTransfer:Zone:DATACENTER_MID_ZN_6 | 7.31 | 0.00 | 02-JAN-07:10 | 6040.74 | 01-JAN-17:10 |
General:Heating:EnergyTransfer:Zone:DATACENTER_MID_ZN_6 | 7.31 | 0.00 | 02-JAN-07:10 | 6040.74 | 01-JAN-17:10 |
Cooling:EnergyTransfer:Zone:DATACENTER_MID_ZN_6 | 1120.17 | 0.00 | 01-JAN-00:10 | 80680.95 | 21-APR-18:10 |
General:Cooling:EnergyTransfer:Zone:DATACENTER_MID_ZN_6 | 1120.17 | 0.00 | 01-JAN-00:10 | 80680.95 | 21-APR-18:10 |
EnergyTransfer:Zone:DATACENTER_TOP_ZN_6 | 100.88 | 0.90 | 21-JAN-15:50 | 8037.47 | 21-APR-18:10 |
Heating:EnergyTransfer:Zone:DATACENTER_TOP_ZN_6 | 0.98 | 0.00 | 02-JAN-07:10 | 626.33 | 05-JAN-23:50 |
General:Heating:EnergyTransfer:Zone:DATACENTER_TOP_ZN_6 | 0.98 | 0.00 | 02-JAN-07:10 | 626.33 | 05-JAN-23:50 |
Cooling:EnergyTransfer:Zone:DATACENTER_TOP_ZN_6 | 99.90 | 0.00 | 01-JAN-00:10 | 8037.47 | 21-APR-18:10 |
General:Cooling:EnergyTransfer:Zone:DATACENTER_TOP_ZN_6 | 99.90 | 0.00 | 01-JAN-00:10 | 8037.47 | 21-APR-18:10 |
EnergyTransfer:Zone:DATACENTER_BASEMENT_ZN_6 | 7152.33 | 81390.27 | 01-JAN-10:00 | 369256.66 | 10-AUG-16:00 |
Heating:EnergyTransfer:Zone:DATACENTER_BASEMENT_ZN_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:DATACENTER_BASEMENT_ZN_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:DATACENTER_BASEMENT_ZN_6 | 7152.33 | 81390.27 | 01-JAN-10:00 | 369256.66 | 10-AUG-16:00 |
General:Cooling:EnergyTransfer:Zone:DATACENTER_BASEMENT_ZN_6 | 7152.33 | 81390.27 | 01-JAN-10:00 | 369256.66 | 10-AUG-16:00 |
PlantLoopHeatingDemand:Facility | 3480.28 | 0.00 | 02-JAN-00:40 | 2742146.16 | 09-JAN-07:10 |
PlantLoopHeatingDemand:Plant | 499.04 | 0.00 | 01-JAN-00:10 | 61550.23 | 24-FEB-12:30 |
WaterSystems:PlantLoopHeatingDemand | 499.04 | 0.00 | 01-JAN-00:10 | 61550.23 | 24-FEB-12:30 |
General:WaterSystems:PlantLoopHeatingDemand | 499.04 | 0.00 | 01-JAN-00:10 | 61550.23 | 24-FEB-12:30 |
EnergyTransfer:HVAC | 21509.90 | 118293.85 | 01-JAN-10:00 | 3409373.13 | 05-JUL-10:40 |
HeatingCoils:EnergyTransfer | 2981.24 | 0.00 | 01-JAN-10:00 | 2722375.85 | 09-JAN-07:10 |
PlantLoopHeatingDemand:HVAC | 2981.24 | 0.00 | 01-JAN-10:00 | 2722375.85 | 09-JAN-07:10 |
HeatingCoils:PlantLoopHeatingDemand | 2981.24 | 0.00 | 01-JAN-10:00 | 2722375.85 | 09-JAN-07:10 |
CoolingCoils:EnergyTransfer | 13571.53 | 97237.02 | 09-JAN-07:10 | 3409373.13 | 05-JUL-10:40 |
HeatRecoveryForHeating:EnergyTransfer | 4768.68 | 0.00 | 01-JAN-00:10 | 1267341.92 | 13-JAN-17:10 |
HeatRecoveryForCooling:EnergyTransfer | 188.46 | 0.00 | 01-JAN-00:10 | 644511.73 | 15-JUL-14:00 |
EnergyTransfer:Plant | 15393.32 | 0.00 | 02-JAN-00:40 | 8536060.70 | 05-JUL-10:40 |
LoopToLoop:EnergyTransfer | 4033.57 | -285.92 | 25-JAN-20:00 | 2843358.06 | 05-JUL-10:40 |
WaterSystems:EnergyTransfer | 499.04 | 0.00 | 01-JAN-00:10 | 61550.23 | 24-FEB-12:30 |
WaterUse:WaterSystems:EnergyTransfer | 499.04 | 0.00 | 01-JAN-00:10 | 61550.23 | 24-FEB-12:30 |
Boilers:EnergyTransfer | 2954.89 | 0.00 | 01-JAN-10:00 | 2760293.78 | 09-JAN-07:10 |
Chillers:EnergyTransfer | 3673.95 | 0.00 | 01-JAN-00:10 | 2647353.66 | 05-JUL-10:20 |
HeatRejection:EnergyTransfer | 4231.87 | 0.00 | 01-JAN-00:10 | 3034670.01 | 05-JUL-10:20 |
General:HeatRejection:EnergyTransfer | 4231.87 | 0.00 | 01-JAN-00:10 | 3034670.01 | 05-JUL-10:20 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
BASEMENT | 0.000 | 0.000 | 3.025 | -638.475 | 0.000 | 0.000 | 93.128 | 240.449 | 424.397 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -122.523 |
CORE_BOTTOM | 0.000 | 0.000 | 0.004 | -586.861 | 0.000 | 0.000 | 83.694 | 215.940 | 321.286 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -34.063 |
CORE_MID | 0.000 | 0.000 | 26.773 | -4202.979 | 0.000 | 0.000 | 863.695 | 2159.397 | 3212.845 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -2059.731 |
CORE_TOP | 0.000 | 0.000 | 32.261 | -349.360 | 0.000 | 0.000 | 89.596 | 215.940 | 321.285 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -309.721 |
PERIMETER_BOT_ZN_3 | 0.000 | 0.000 | 4.621 | -62.223 | 0.000 | 0.000 | 11.149 | 18.782 | 40.342 | 25.377 | 0.000 | 0.033 | 33.013 | 0.000 | -60.694 | 0.000 | -10.400 | 0.000 |
PERIMETER_BOT_ZN_2 | 0.000 | 0.000 | 3.304 | -64.486 | 0.000 | 0.000 | 7.322 | 12.071 | 25.998 | 50.438 | 0.000 | 0.026 | 9.003 | 0.000 | -36.866 | 0.000 | -6.810 | -0.000 |
PERIMETER_BOT_ZN_1 | 0.000 | 0.000 | 4.387 | -102.775 | 0.000 | 0.000 | 11.107 | 18.644 | 40.343 | 107.294 | 0.000 | 0.033 | 0.001 | 0.000 | -53.318 | 0.000 | -10.357 | -15.357 |
PERIMETER_BOT_ZN_4 | 0.000 | 0.000 | 0.777 | -97.088 | 0.000 | 0.000 | 7.143 | 12.051 | 25.998 | 50.238 | 0.000 | 0.021 | 49.071 | 0.000 | -40.893 | 0.000 | -7.316 | 0.000 |
PERIMETER_MID_ZN_3 | 0.000 | 0.000 | 323.552 | -402.399 | 0.000 | 0.000 | 115.630 | 187.996 | 403.423 | 261.749 | 0.000 | 0.792 | 0.004 | 0.000 | -564.222 | 0.000 | -223.101 | -103.420 |
PERIMETER_MID_ZN_2 | 0.000 | 0.000 | 188.551 | -505.632 | 0.000 | 0.000 | 55.208 | 120.756 | 259.981 | 507.028 | 0.000 | 0.568 | 0.006 | 0.000 | -349.556 | 0.000 | -149.475 | -127.429 |
PERIMETER_MID_ZN_1 | 0.000 | 0.000 | 185.707 | -853.357 | 0.000 | 0.000 | 113.417 | 186.548 | 403.429 | 1074.425 | 0.000 | 0.726 | 0.001 | 0.000 | -515.657 | 0.000 | -231.082 | -364.157 |
PERIMETER_MID_ZN_4 | 0.000 | 0.000 | 151.120 | -548.319 | 0.000 | 0.000 | 75.430 | 120.552 | 259.979 | 513.359 | 0.000 | 0.513 | 0.003 | 0.000 | -369.266 | 0.000 | -152.381 | -50.989 |
PERIMETER_TOP_ZN_3 | 0.000 | 0.000 | 67.434 | -37.422 | 0.000 | 0.000 | 11.786 | 18.800 | 40.342 | 26.841 | 0.000 | 0.100 | 0.000 | 0.000 | -54.012 | 0.000 | -26.630 | -47.239 |
PERIMETER_TOP_ZN_2 | 0.000 | 0.000 | 39.489 | -45.205 | 0.000 | 0.000 | 7.553 | 12.076 | 25.998 | 51.037 | 0.000 | 0.066 | 0.001 | 0.000 | -33.650 | 0.000 | -17.986 | -39.379 |
PERIMETER_TOP_ZN_1 | 0.000 | 0.000 | 44.891 | -75.292 | 0.000 | 0.000 | 11.539 | 18.655 | 40.343 | 108.142 | 0.000 | 0.086 | 0.001 | 0.000 | -49.363 | 0.000 | -27.556 | -71.444 |
PERIMETER_TOP_ZN_4 | 0.000 | 0.000 | 32.867 | -49.527 | 0.000 | 0.000 | 7.628 | 12.055 | 25.998 | 51.613 | 0.000 | 0.061 | 0.001 | 0.000 | -35.622 | 0.000 | -18.315 | -26.759 |
DATACENTER_BOT_ZN_6 | 0.000 | 0.000 | 0.102 | -133.564 | 0.000 | 0.000 | 0.950 | 5.965 | 153.881 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -27.334 |
DATACENTER_MID_ZN_6 | 0.000 | 0.000 | 7.312 | -1120.166 | 0.000 | 0.000 | 9.553 | 59.652 | 1538.806 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -495.156 |
DATACENTER_TOP_ZN_6 | 0.000 | 0.000 | 0.980 | -99.903 | 0.000 | 0.000 | 0.961 | 5.965 | 153.881 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -61.884 |
DATACENTER_BASEMENT_ZN_6 | 0.000 | 0.000 | 0.000 | -7152.333 | 0.000 | 0.000 | 20.518 | 67.796 | 7494.857 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -430.839 |
GROUNDFLOOR_PLENUM | 9.592 | -49.847 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.055 | 62.052 | 0.000 | 0.000 | 0.000 | -21.852 | -0.000 |
MIDFLOOR_PLENUM | 272.646 | -346.600 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1.035 | 442.999 | 0.000 | 0.000 | 0.000 | -370.081 | -0.008 |
TOPFLOOR_PLENUM | 99.979 | -41.203 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.081 | 0.001 | 0.000 | 0.000 | 0.000 | -40.092 | -18.765 |
Total Facility | 382.217 | -437.650 | 1117.157 | -17127.365 | 0.000 | 0.000 | 1597.006 | 3710.089 | 15213.411 | 2827.543 | 0.000 | 4.198 | 596.156 | 0.000 | -2163.118 | 0.000 | -1313.434 | -4406.199 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BASEMENT | 02-OCT-03:02 | 0.00 | 0.00 | 0.00 | -114354.76 | 0.00 | 0.00 | 0.00 | 1166.43 | 13457.54 | 0.00 | 0.00 | 0.00 | 99730.79 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_BOTTOM | 19-JUN-03:02 | 0.00 | 0.00 | 0.00 | -93552.95 | 0.00 | 0.00 | 0.00 | 1047.53 | 8057.15 | 0.00 | 0.00 | 0.00 | 84448.26 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 30-MAY-03:02 | 0.00 | 0.00 | 0.00 | -898470.73 | 0.00 | 0.00 | 0.00 | 10475.32 | 80571.20 | 0.00 | 0.00 | 0.00 | 807424.21 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 05-JUL-03:02 | 0.00 | 0.00 | 0.00 | -85500.78 | 0.00 | 0.00 | 0.00 | 1047.53 | 8057.12 | 0.00 | 0.00 | 0.00 | 76396.13 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 24-JUL-05:03 | 0.00 | 0.00 | 0.00 | -13143.84 | 0.00 | 0.00 | 102.91 | 161.60 | 1011.70 | 2955.61 | 0.00 | 0.00 | 8958.60 | 0.00 | -0.00 | 0.00 | -46.58 | 0.00 |
PERIMETER_BOT_ZN_2 | 20-AUG-08:32 | 0.00 | 0.00 | 0.00 | -23010.84 | 0.00 | 0.00 | 21.96 | 52.07 | 488.98 | 18099.50 | 0.00 | 0.00 | 4607.11 | 0.00 | -0.00 | 0.00 | -258.77 | 0.00 |
PERIMETER_BOT_ZN_1 | 22-OCT-12:41 | 0.00 | 0.00 | 0.00 | -30294.46 | 0.00 | 0.00 | 31.51 | 80.80 | 758.78 | 29086.79 | 0.00 | 0.00 | 654.49 | 0.00 | -0.00 | 0.00 | -317.91 | 0.00 |
PERIMETER_BOT_ZN_4 | 03-SEP-17:11 | 0.00 | 0.00 | 0.00 | -28612.97 | 0.00 | 0.00 | 0.00 | 52.07 | 488.98 | 15341.85 | 0.00 | 0.00 | 12905.58 | 0.00 | -0.00 | 0.00 | -175.50 | 0.00 |
PERIMETER_MID_ZN_3 | 30-JUN-03:02 | 0.00 | 0.00 | 0.00 | -121453.79 | 0.00 | 0.00 | 0.00 | 1315.28 | 10116.97 | 0.00 | 0.00 | 0.00 | 112929.41 | 0.00 | -2811.07 | 0.00 | -96.80 | 0.00 |
PERIMETER_MID_ZN_2 | 18-JUN-08:62 | 0.00 | 0.00 | 0.00 | -239648.04 | 0.00 | 0.00 | 218.18 | 520.69 | 4889.82 | 178466.91 | 0.00 | 0.00 | 61322.68 | 0.00 | -0.00 | 0.00 | -5770.23 | 0.00 |
PERIMETER_MID_ZN_1 | 22-OCT-13:02 | 0.00 | 0.00 | 0.00 | -289048.65 | 0.00 | 0.00 | 289.99 | 807.99 | 7587.84 | 280331.63 | 0.00 | 0.00 | 6340.37 | 0.00 | -0.00 | 0.00 | -6309.18 | 0.00 |
PERIMETER_MID_ZN_4 | 14-MAY-17:21 | 0.00 | 0.00 | 0.00 | -264178.73 | 0.00 | 0.00 | 0.00 | 520.69 | 4889.79 | 199640.95 | 0.00 | 0.00 | 65087.53 | 0.00 | -0.00 | 0.00 | -5960.23 | 0.00 |
PERIMETER_TOP_ZN_3 | 28-JUN-05:03 | 0.00 | 0.00 | 0.00 | -14307.93 | 0.00 | 0.00 | 111.61 | 161.60 | 1011.70 | 5079.37 | 0.00 | 0.00 | 7943.66 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 18-JUN-09:51 | 0.00 | 0.00 | 0.00 | -24542.01 | 0.00 | 0.00 | 21.28 | 52.07 | 488.98 | 12702.29 | 0.00 | 0.00 | 11702.88 | 0.00 | -0.00 | 0.00 | -425.49 | 0.00 |
PERIMETER_TOP_ZN_1 | 22-OCT-14:11 | 0.00 | 0.00 | 0.00 | -31564.85 | 0.00 | 0.00 | 33.05 | 80.80 | 758.78 | 19582.74 | 0.00 | 0.00 | 11922.36 | 0.00 | -0.00 | 0.00 | -812.87 | 0.00 |
PERIMETER_TOP_ZN_4 | 04-JUL-16:31 | 0.00 | 0.00 | 0.00 | -27469.25 | 0.00 | 0.00 | 20.09 | 52.07 | 488.98 | 11667.21 | 0.00 | 0.00 | 15448.35 | 0.00 | -0.00 | 0.00 | -207.45 | 0.00 |
DATACENTER_BOT_ZN_6 | 21-APR-18:10 | 0.00 | 0.00 | 0.00 | -8473.96 | 0.00 | 0.00 | 10.62 | 173.61 | 7794.42 | 0.00 | 0.00 | 0.00 | 495.30 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
DATACENTER_MID_ZN_6 | 21-APR-18:10 | 0.00 | 0.00 | 0.00 | -80674.92 | 0.00 | 0.00 | 106.16 | 1736.14 | 77944.22 | 0.00 | 0.00 | 0.00 | 888.40 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
DATACENTER_TOP_ZN_6 | 21-APR-18:10 | 0.00 | 0.00 | 0.00 | -8036.88 | 0.00 | 0.00 | 10.62 | 173.61 | 7794.42 | 0.00 | 0.00 | 0.00 | 58.23 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
DATACENTER_BASEMENT_ZN_6 | 09-AUG-21:02 | 0.00 | 0.00 | 0.00 | -370421.38 | 0.00 | 0.00 | 113.19 | 657.76 | 379632.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -9982.10 |
GROUNDFLOOR_PLENUM | 17-JUL-05:13 | 0.00 | -11292.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11413.29 | 0.00 | -0.00 | 0.00 | -121.00 | 0.00 |
MIDFLOOR_PLENUM | 02-DEC-04:01 | 0.00 | -96532.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 135214.38 | 0.00 | -0.00 | 0.00 | -38681.93 | 0.00 |
TOPFLOOR_PLENUM | 30-JUN-14:50 | 0.00 | -19785.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 353.33 | 19432.27 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 01-JUL-05:02 | 0.00 | -6867.62 | 0.00 | -1822982.46 | 0.00 | 0.00 | 16073.60 | 35353.01 | 504945.49 | 123574.08 | 0.00 | 0.00 | 1180933.35 | 0.00 | -23685.00 | 0.00 | -7344.45 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BASEMENT | 29-JUL-16:01 | 0.00 | 0.00 | 17561.65 | 0.00 | 0.00 | 0.00 | 520.12 | 1166.43 | 13457.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -32705.74 |
CORE_BOTTOM | 02-JAN-06:01 | 0.00 | 0.00 | 16037.55 | 0.00 | 0.00 | 0.00 | 1130.23 | 2095.06 | 8057.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -27319.99 |
CORE_MID | 02-JAN-04:01 | 0.00 | 0.00 | 625140.16 | 0.00 | 0.00 | 0.00 | 0.00 | 10475.32 | 80571.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -716186.68 |
CORE_TOP | 09-JAN-04:11 | 0.00 | 0.00 | 81974.67 | 0.00 | 0.00 | 0.00 | 0.00 | 1047.53 | 8057.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -91079.33 |
PERIMETER_BOT_ZN_3 | 01-JAN-09:18 | 0.00 | 0.00 | 13733.59 | 0.00 | 0.00 | 0.00 | 86.62 | 91.64 | 758.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -4371.54 | 0.00 | -1234.41 | -9064.68 |
PERIMETER_BOT_ZN_2 | 02-JAN-04:01 | 0.00 | 0.00 | 16081.23 | 0.00 | 0.00 | 0.00 | 0.00 | 84.76 | 651.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2939.84 | 0.00 | -741.40 | -13136.73 |
PERIMETER_BOT_ZN_1 | 09-JAN-04:01 | 0.00 | 0.00 | 22387.18 | 0.00 | 0.00 | 0.00 | 0.00 | 131.53 | 1011.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -6120.34 | 0.00 | -930.02 | -16480.06 |
PERIMETER_BOT_ZN_4 | 09-JAN-04:01 | 0.00 | 0.00 | 13672.25 | 0.00 | 0.00 | 0.00 | 0.00 | 84.76 | 651.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -4256.27 | 0.00 | -640.04 | -9512.67 |
PERIMETER_MID_ZN_3 | 24-DEC-22:32 | 0.00 | 0.00 | 137983.69 | 0.00 | 0.00 | 0.00 | 0.00 | 1315.28 | 7587.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -55010.86 | 0.00 | -27756.75 | -64119.10 |
PERIMETER_MID_ZN_2 | 24-DEC-07:12 | 0.00 | 0.00 | 199872.51 | 0.00 | 0.00 | 0.00 | 586.51 | 847.62 | 4889.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -38639.18 | 0.00 | -24718.60 | -142838.68 |
PERIMETER_MID_ZN_1 | 24-DEC-07:12 | 0.00 | 0.00 | 239881.99 | 0.00 | 0.00 | 0.00 | 905.95 | 1315.31 | 7587.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -58226.04 | 0.00 | -36959.35 | -154505.71 |
PERIMETER_MID_ZN_4 | 01-JAN-08:61 | 0.00 | 0.00 | 206947.05 | 0.00 | 0.00 | 0.00 | 593.62 | 847.62 | 4889.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -35035.86 | 0.00 | -21229.98 | -157012.23 |
PERIMETER_TOP_ZN_3 | 09-JAN-04:11 | 0.00 | 0.00 | 19146.99 | 0.00 | 0.00 | 0.00 | 0.00 | 131.53 | 1011.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -5688.59 | 0.00 | -2707.11 | -11894.52 |
PERIMETER_TOP_ZN_2 | 09-JAN-04:11 | 0.00 | 0.00 | 21541.69 | 0.00 | 0.00 | 0.00 | 0.00 | 84.76 | 651.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3793.63 | 0.00 | -1821.17 | -16663.62 |
PERIMETER_TOP_ZN_1 | 09-JAN-04:11 | 0.00 | 0.00 | 27336.22 | 0.00 | 0.00 | 0.00 | 0.00 | 131.53 | 1011.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -5854.77 | 0.00 | -2732.18 | -19892.51 |
PERIMETER_TOP_ZN_4 | 09-JAN-04:11 | 0.00 | 0.00 | 23625.53 | 0.00 | 0.00 | 0.00 | 0.00 | 84.76 | 651.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3910.62 | 0.00 | -1832.16 | -18619.48 |
DATACENTER_BOT_ZN_6 | 01-JAN-19:50 | 0.00 | 0.00 | 600.81 | 0.00 | 0.00 | 0.00 | 0.00 | 28.94 | 1948.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2578.36 |
DATACENTER_MID_ZN_6 | 01-JAN-17:10 | 0.00 | 0.00 | 6040.76 | 0.00 | 0.00 | 0.00 | 70.35 | 289.38 | 19486.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -25886.54 |
DATACENTER_TOP_ZN_6 | 09-JAN-23:35 | 0.00 | 0.00 | 629.34 | 0.00 | 0.00 | 0.00 | 6.09 | 28.94 | 1948.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2612.97 |
DATACENTER_BASEMENT_ZN_6 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GROUNDFLOOR_PLENUM | 28-DEC-06:01 | 16336.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -247.12 | -16089.51 |
MIDFLOOR_PLENUM | 02-JAN-06:23 | 224295.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -5715.92 | -218580.03 |
TOPFLOOR_PLENUM | 09-JAN-05:09 | 35723.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -5056.08 | -30667.76 |
Total Facility | 02-JAN-06:01 | 125496.42 | 81883.18 | 1541890.02 | -81883.18 | 0.00 | 0.00 | 23331.81 | 39207.80 | 268362.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -169835.41 | 0.00 | -22344.40 | -1806108.93 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
VAV_BOT WITH REHEAT | 11.6062 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 10.1100 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
VAV_MID WITH REHEAT | 111.1172 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 93.8786 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
VAV_TOP WITH REHEAT | 11.4640 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 10.0436 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
CAV_BAS | 5.9096 | 0.0000 | 149.6021 | 1.0000 | Calculated from schedules | 1.2002 | 5.9096 | 0.2031 | 1.0000 | Not calculated | 1.2002 | 0.2031 | ||
AIRLOOP DATACENTER BASEMENT | 22.2820 | 0.0000 | 42.1814 | 1.0000 | Calculated from schedules | 0.3384 | 22.2821 | 0.0152 | 1.0000 | Not calculated | 0.3384 | 0.0152 | ||
AIRLOOP DATACENTER BOT | 0.5244 | 0.0000 | 1.9486 | 1.0000 | Calculated from schedules | 0.0156 | 0.5244 | 0.0298 | 1.0000 | Not calculated | 0.0156 | 0.0298 | ||
AIRLOOP DATACENTER MID | 5.0273 | 0.0000 | 19.4861 | 1.0000 | Calculated from schedules | 0.1563 | 5.0273 | 0.0311 | 1.0000 | Not calculated | 0.1563 | 0.0311 | ||
AIRLOOP DATACENTER TOP | 0.5099 | 0.0000 | 1.9486 | 1.0000 | Calculated from schedules | 0.0156 | 0.5099 | 0.0307 | 1.0000 | Not calculated | 0.0156 | 0.0307 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
VAV_BOT WITH REHEAT | 5.8031 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 3.5809 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
VAV_MID WITH REHEAT | 55.5586 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 35.0786 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
VAV_TOP WITH REHEAT | 5.7320 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 3.6792 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
CAV_BAS | 5.9096 | 0.0000 | 149.6021 | 1.0000 | Calculated from schedules | 1.2002 | 5.9096 | 1.0000 | 1.0000 | Not calculated | 1.2002 | 0.2031 | ||
AIRLOOP DATACENTER BASEMENT | 22.2820 | 0.0000 | 42.1814 | 1.0000 | Calculated from schedules | 0.3384 | 22.2820 | 1.0000 | 1.0000 | Not calculated | 0.3384 | 0.0152 | ||
AIRLOOP DATACENTER BOT | 0.5244 | 0.0000 | 1.9486 | 1.0000 | Calculated from schedules | 0.0156 | 0.5244 | 1.0000 | 1.0000 | Not calculated | 0.0156 | 0.0298 | ||
AIRLOOP DATACENTER MID | 5.0273 | 0.0000 | 19.4861 | 1.0000 | Calculated from schedules | 0.1563 | 5.0273 | 1.0000 | 1.0000 | Not calculated | 0.1563 | 0.0311 | ||
AIRLOOP DATACENTER TOP | 0.5099 | 0.0000 | 1.9486 | 1.0000 | Calculated from schedules | 0.0156 | 0.5099 | 1.0000 | 1.0000 | Not calculated | 0.0156 | 0.0307 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
BASEMENT | CAV_BAS | 0.000000 | 149.6021 | 0.000432 | 2779.43 | 1.2002 | 1.0000 | 1.2002 | 1.000 | 1.2002 |
CORE_BOTTOM | VAV_BOT WITH REHEAT | 0.000000 | 134.3532 | 0.000432 | 2496.12 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORE_MID | VAV_MID WITH REHEAT | 0.000000 | 1343.5320 | 0.000432 | 24961.20 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORE_TOP | VAV_TOP WITH REHEAT | 0.000000 | 134.3532 | 0.000432 | 2496.12 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_3 | VAV_BOT WITH REHEAT | 0.000000 | 16.8694 | 0.000432 | 313.41 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_2 | VAV_BOT WITH REHEAT | 0.000000 | 10.8713 | 0.000432 | 201.98 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_1 | VAV_BOT WITH REHEAT | 0.000000 | 16.8698 | 0.000432 | 313.42 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_4 | VAV_BOT WITH REHEAT | 0.000000 | 10.8713 | 0.000432 | 201.98 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_3 | VAV_MID WITH REHEAT | 0.000000 | 168.6939 | 0.000432 | 3134.13 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_2 | VAV_MID WITH REHEAT | 0.000000 | 108.7127 | 0.000432 | 2019.75 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_1 | VAV_MID WITH REHEAT | 0.000000 | 168.6975 | 0.000432 | 3134.20 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_4 | VAV_MID WITH REHEAT | 0.000000 | 108.7127 | 0.000432 | 2019.75 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_3 | VAV_TOP WITH REHEAT | 0.000000 | 16.8694 | 0.000432 | 313.41 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_2 | VAV_TOP WITH REHEAT | 0.000000 | 10.8713 | 0.000432 | 201.98 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_1 | VAV_TOP WITH REHEAT | 0.000000 | 16.8698 | 0.000432 | 313.42 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_4 | VAV_TOP WITH REHEAT | 0.000000 | 10.8713 | 0.000432 | 201.98 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
DATACENTER_BOT_ZN_6 | AIRLOOP DATACENTER BOT | 0.000000 | 1.9486 | 0.000432 | 36.20 | 0.0156 | 1.0000 | 0.0156 | 1.000 | 0.0156 |
DATACENTER_MID_ZN_6 | AIRLOOP DATACENTER MID | 0.000000 | 19.4861 | 0.000432 | 362.03 | 0.1563 | 1.0000 | 0.1563 | 1.000 | 0.1563 |
DATACENTER_TOP_ZN_6 | AIRLOOP DATACENTER TOP | 0.000000 | 1.9486 | 0.000432 | 36.20 | 0.0156 | 1.0000 | 0.0156 | 1.000 | 0.0156 |
DATACENTER_BASEMENT_ZN_6 | AIRLOOP DATACENTER BASEMENT | 0.000000 | 42.1814 | 0.000432 | 783.68 | 0.3384 | 1.0000 | 0.3384 | 1.000 | 0.3384 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
VAV_BOT WITH REHEAT | 0.00 | 0.000432 | 3526.9033 | 0.0000 | 0.0000 | 0.0000 | |
VAV_MID WITH REHEAT | 0.00 | 0.000432 | 35269.0328 | 0.0000 | 0.0000 | 0.0000 | |
VAV_TOP WITH REHEAT | 0.00 | 0.000432 | 3526.9033 | 0.0000 | 0.0000 | 0.0000 | |
CAV_BAS | 0.000000 | 149.60 | 0.000432 | 2779.4266 | 1.2002 | 1.2002 | 1.2002 |
AIRLOOP DATACENTER BASEMENT | 0.000000 | 42.18 | 0.000432 | 783.6794 | 0.3384 | 0.3384 | 0.3384 |
AIRLOOP DATACENTER BOT | 0.000000 | 1.95 | 0.000432 | 36.2027 | 0.0156 | 0.0156 | 0.0156 |
AIRLOOP DATACENTER MID | 0.000000 | 19.49 | 0.000432 | 362.0274 | 0.1563 | 0.1563 | 0.1563 |
AIRLOOP DATACENTER TOP | 0.000000 | 1.95 | 0.000432 | 36.2027 | 0.0156 | 0.0156 | 0.0156 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BASEMENT | CAV_BAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 5.9096 | 5.9096 | 5.9096 | No | 1.2002 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_BOTTOM | VAV_BOT WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 6.1872 | 6.1872 | 1.9551 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_MID | VAV_MID WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 58.1131 | 58.1131 | 19.1773 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_TOP | VAV_TOP WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 5.7146 | 5.7146 | 1.9544 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_3 | VAV_BOT WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.9683 | 0.9683 | 0.2905 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_2 | VAV_BOT WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.2902 | 1.2902 | 0.3870 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_1 | VAV_BOT WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.5987 | 1.5987 | 0.4796 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_4 | VAV_BOT WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.5619 | 1.5619 | 0.4686 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_3 | VAV_MID WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 9.0138 | 9.0138 | 2.7041 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_2 | VAV_MID WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 13.5454 | 13.5454 | 4.0636 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_1 | VAV_MID WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 16.1758 | 16.1758 | 4.8527 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_4 | VAV_MID WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 14.2691 | 14.2691 | 4.2807 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_3 | VAV_TOP WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.1849 | 1.1849 | 0.3555 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_2 | VAV_TOP WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.3535 | 1.3535 | 0.4061 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_1 | VAV_TOP WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.7139 | 1.7139 | 0.5142 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_4 | VAV_TOP WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.4971 | 1.4971 | 0.4491 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
DATACENTER_BOT_ZN_6 | AIRLOOP DATACENTER BOT | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5244 | 0.5244 | 0.5244 | No | 0.0156 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
DATACENTER_MID_ZN_6 | AIRLOOP DATACENTER MID | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 5.0273 | 5.0273 | 5.0273 | No | 0.1563 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
DATACENTER_TOP_ZN_6 | AIRLOOP DATACENTER TOP | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5099 | 0.5099 | 0.5099 | No | 0.0156 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
DATACENTER_BASEMENT_ZN_6 | AIRLOOP DATACENTER BASEMENT | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 22.2820 | 22.2820 | 22.2820 | No | 0.3384 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
VAV_BOT WITH REHEAT | 11.6062 | 10.1100 | 11.6062 | 3.5809 | 0.0000 | 1.0000 |
VAV_MID WITH REHEAT | 111.1172 | 93.8786 | 111.1172 | 35.0786 | 0.0000 | 1.0000 |
VAV_TOP WITH REHEAT | 11.4640 | 10.0436 | 11.4640 | 3.6792 | 0.0000 | 1.0000 |
CAV_BAS | 5.9096 | 5.9096 | 5.9096 | 5.9096 | 1.2002 | 1.0000 |
AIRLOOP DATACENTER BASEMENT | 22.2820 | 22.2821 | 22.2820 | 22.2820 | 0.3384 | 1.0000 |
AIRLOOP DATACENTER BOT | 0.5244 | 0.5244 | 0.5244 | 0.5244 | 0.0156 | 1.0000 |
AIRLOOP DATACENTER MID | 5.0273 | 5.0273 | 5.0273 | 5.0273 | 0.1563 | 1.0000 |
AIRLOOP DATACENTER TOP | 0.5099 | 0.5099 | 0.5099 | 0.5099 | 0.0156 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BASEMENT | CAV_BAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 5.9096 | 5.9096 | 5.9096 | No | 1.2002 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_BOTTOM | VAV_BOT WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 3.0936 | 3.0936 | 1.9551 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_MID | VAV_MID WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 29.0566 | 29.0566 | 19.1773 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_TOP | VAV_TOP WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.8573 | 2.8573 | 1.9544 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_3 | VAV_BOT WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4842 | 0.4842 | 0.2905 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_2 | VAV_BOT WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6451 | 0.6451 | 0.3870 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_1 | VAV_BOT WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7993 | 0.7993 | 0.4796 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_4 | VAV_BOT WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7809 | 0.7809 | 0.4686 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_3 | VAV_MID WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 4.5069 | 4.5069 | 2.7041 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_2 | VAV_MID WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 6.7727 | 6.7727 | 4.0636 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_1 | VAV_MID WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 8.0879 | 8.0879 | 4.8527 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_4 | VAV_MID WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 7.1346 | 7.1346 | 4.2807 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_3 | VAV_TOP WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5924 | 0.5924 | 0.3555 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_2 | VAV_TOP WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6768 | 0.6768 | 0.4061 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_1 | VAV_TOP WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.8570 | 0.8570 | 0.5142 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_4 | VAV_TOP WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7485 | 0.7485 | 0.4491 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
DATACENTER_BOT_ZN_6 | AIRLOOP DATACENTER BOT | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5244 | 0.5244 | 0.5244 | No | 0.0156 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
DATACENTER_MID_ZN_6 | AIRLOOP DATACENTER MID | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 5.0273 | 5.0273 | 5.0273 | No | 0.1563 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
DATACENTER_TOP_ZN_6 | AIRLOOP DATACENTER TOP | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.5099 | 0.5099 | 0.5099 | No | 0.0156 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
DATACENTER_BASEMENT_ZN_6 | AIRLOOP DATACENTER BASEMENT | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 22.2820 | 22.2820 | 22.2820 | No | 0.3384 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
VAV_BOT WITH REHEAT | 5.8031 | 3.5809 | 3.5809 | 3.5809 | 0.0000 | 1.0000 |
VAV_MID WITH REHEAT | 55.5586 | 35.0786 | 35.0786 | 35.0786 | 0.0000 | 1.0000 |
VAV_TOP WITH REHEAT | 5.7320 | 3.6792 | 3.6792 | 3.6792 | 0.0000 | 1.0000 |
CAV_BAS | 5.9096 | 5.9096 | 5.9096 | 5.9096 | 1.2002 | 1.0000 |
AIRLOOP DATACENTER BASEMENT | 22.2820 | 22.2820 | 22.2820 | 22.2820 | 0.3384 | 1.0000 |
AIRLOOP DATACENTER BOT | 0.5244 | 0.5244 | 0.5244 | 0.5244 | 0.0156 | 1.0000 |
AIRLOOP DATACENTER MID | 5.0273 | 5.0273 | 5.0273 | 5.0273 | 0.1563 | 1.0000 |
AIRLOOP DATACENTER TOP | 0.5099 | 0.5099 | 0.5099 | 0.5099 | 0.0156 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** International Falls Intl Ap MN USA TMY3 WMO#=727470 |
Total gross floor area [m2] | 46320.38 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
BASEMENT | 2779.43 | 2779.43 | 0.00 | 113.98 |
CORE_BOTTOM | 2496.12 | 2496.12 | 0.00 | 113.98 |
CORE_MID | 2496.12 | 2496.12 | 0.00 | 113.98 |
CORE_TOP | 2496.12 | 2496.12 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_3 | 313.41 | 313.41 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_2 | 201.98 | 201.98 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_1 | 313.42 | 313.42 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_4 | 201.98 | 201.98 | 0.00 | 113.98 |
PERIMETER_MID_ZN_3 | 313.41 | 313.41 | 0.00 | 113.98 |
PERIMETER_MID_ZN_2 | 201.98 | 201.98 | 0.00 | 96.54 |
PERIMETER_MID_ZN_1 | 313.42 | 313.42 | 0.00 | 113.98 |
PERIMETER_MID_ZN_4 | 201.98 | 201.98 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_3 | 313.41 | 313.41 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_2 | 201.98 | 201.98 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_1 | 313.42 | 313.42 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_4 | 201.98 | 201.98 | 0.00 | 113.98 |
DATACENTER_BOT_ZN_6 | 36.20 | 36.20 | 0.00 | 113.98 |
DATACENTER_MID_ZN_6 | 36.20 | 36.20 | 0.00 | 113.98 |
DATACENTER_TOP_ZN_6 | 36.20 | 36.20 | 0.00 | 113.98 |
DATACENTER_BASEMENT_ZN_6 | 783.68 | 783.68 | 0.00 | 113.98 |
GROUNDFLOOR_PLENUM | 3563.11 | 3563.11 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 3563.11 | 3563.11 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 3563.11 | 3563.11 | 0.00 | 0.00 |
Totals | 46320.38 | 46320.38 | 0.00 |
Data | |
Number of hours heating loads not met | 206.33 |
Number of hours cooling loads not met | 149.67 |
Number of hours not met | 356.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heating -- Boiler | 0.00 | 0.00 | 3895.57 | 3353627.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heating -- Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- General | 2944.32 | 505731.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 3710.09 | 352853.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 672.82 | 54335.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 5871.99 | 320838.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- DataCenterPlugLoads | 9341.42 | 473165.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Transformer | 87.33 | 5481.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- ElevatorLift | 1848.78 | 113101.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- ElevatorLightsFan | 5.83 | 376.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 2507.30 | 313629.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- General | 502.48 | 81784.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- General | 722.15 | 87722.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- General | 31.19 | 6736.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- General | 56.32 | 6524.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 0.00 | 0.00 | 816.05 | 87558.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 15213.41 | 28302.01 |
Natural Gas | 0.00 | 4711.62 |
Additional | 0.00 | 0.00 |
Total | 15213.41 | 33013.63 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 80.10 |
Space Heating | 0.00 |
Space Cooling | 63.56 |
Fans (All) | 54.13 |
Service Water Heating | 0.00 |
Receptacle Equipment | 328.44 |
Miscellaneous (All) | 611.01 |
Subtotal | 611.01 |
Natural Gas [MJ/m2] | |
Space Heating | 84.10 |
Service Water Heating | 17.62 |
Miscellaneous (All) | 101.72 |
Subtotal | 101.72 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 11.24 |
Space Heating | 11.80 |
Space Cooling | 8.92 |
Fans (All) | 7.59 |
Service Water Heating | 2.47 |
Receptacle Equipment | 46.08 |
Miscellaneous | 11.89 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4472. | 4472. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 6752. | 8760. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6828. | 8760. |
ALWAYS_OFF | 0. | 0. |
LTG_SCH_OFFICE | 2645. | 8760. |
LTG_SCH_DATACENTER | 2921. | 8760. |
EXTERIOR_LIGHT_SCH | 4380. | 4380. |
BLDG_EQUIP_SCH | 4487. | 8760. |
DATACENTER_EQUIP_SCH | 5478. | 8760. |
BLDG_OCC_SCH | 2528. | 5992. |
BLDG_OCC_SCH_W_SB | 1878. | 5056. |
BLDG_OCC_SCH_WO_SB | 2557. | 5992. |
BLDG_ELEVATORS | 2270. | 8760. |
ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
ELEV_LIGHT_FAN_SCH_ADD_DF | 2154. | 8760. |
BLDG_SWH_SCH | 1474. | 6570. |
WORK_EFF_SCH | 0. | 0. |
INFIL_SCH | 3976. | 3976. |
INFIL_SCH_PNNL | 5172. | 8760. |
INFIL_HALF_ON_SCH | 6368. | 8760. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4472. | 4472. |
MINOA_SCHED | 8760. | 8760. |
CORE_BOTTOM SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_BOTTOM SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
CORE_MID SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_MID SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
CORE_TOP SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_TOP SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
SUPPLYFANSCH | 8760. | 8760. |
PERIMETER_MID_ZN_2_MDP_SCH | 2347. | 7824. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_DC_SCH | DATACENTER COOLING SETPOINTS DUAL SP CONTROL | January | 18.00 | 365 | 18.00 | 365 |
CLGSETP_DC_SCH | DATACENTER COOLING SETPOINTS DUAL SP CONTROL | July | 27.00 | 365 | 27.00 | 365 |
HTGSETP_SCH_YES_OPTIMUM | CORE_BOTTOM DUAL SP CONTROL | January | 21.00 | 365 | 15.60 | 365 |
CLGSETP_SCH_YES_OPTIMUM | CORE_BOTTOM DUAL SP CONTROL | July | 24.00 | 365 | 26.70 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Heat Index HoursSafe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
BASEMENT | 8463.50 | 296.50 | 0.00 | 0.00 | 0.00 |
CORE_BOTTOM | 8745.50 | 14.50 | 0.00 | 0.00 | 0.00 |
CORE_MID | 8752.17 | 7.83 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 8759.50 | 0.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 8758.33 | 1.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 8744.00 | 16.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 8734.83 | 25.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 8489.33 | 270.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 8755.83 | 4.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 8724.83 | 35.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 8726.50 | 33.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 8637.17 | 122.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 8757.00 | 3.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 8729.00 | 31.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 8730.50 | 29.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 8663.00 | 97.00 | 0.00 | 0.00 | 0.00 |
DATACENTER_BOT_ZN_6 | 8117.67 | 642.33 | 0.00 | 0.00 | 0.00 |
DATACENTER_MID_ZN_6 | 8111.50 | 648.50 | 0.00 | 0.00 | 0.00 |
DATACENTER_TOP_ZN_6 | 8101.67 | 658.33 | 0.00 | 0.00 | 0.00 |
DATACENTER_BASEMENT_ZN_6 | 8228.50 | 531.50 | 0.00 | 0.00 | 0.00 |
GROUNDFLOOR_PLENUM | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 8741.17 | 18.83 | 0.00 | 0.00 | 0.00 |
Min | 8101.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 8760.00 | 658.33 | 0.00 | 0.00 | 0.00 |
Average | 8608.33 | 151.67 | 0.00 | 0.00 | 0.00 |
Sum | 197991.50 | 3488.50 | 0.00 | 0.00 | 0.00 |
Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
BASEMENT | 367661.67 | 954.33 | 0.00 | 0.00 | 0.00 |
CORE_BOTTOM | 330793.00 | 20.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 330813.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 330810.00 | 3.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 38925.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 38925.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 38925.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 18354.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 38925.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 38925.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 38925.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
DATACENTER_BOT_ZN_6 | 1894.50 | 373.50 | 0.00 | 0.00 | 0.00 |
DATACENTER_MID_ZN_6 | 1890.00 | 378.00 | 0.00 | 0.00 | 0.00 |
DATACENTER_TOP_ZN_6 | 1884.17 | 383.83 | 0.00 | 0.00 | 0.00 |
DATACENTER_BASEMENT_ZN_6 | 90916.17 | 12478.83 | 0.00 | 0.00 | 0.00 |
GROUNDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 367661.67 | 12478.83 | 0.00 | 0.00 | 0.00 |
Average | 79700.50 | 634.41 | 0.00 | 0.00 | 0.00 |
Sum | 1833111.50 | 14591.50 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
BASEMENT | 7859.67 | 900.33 | 0.00 | 0.00 | 0.00 |
CORE_BOTTOM | 8321.17 | 438.83 | 0.00 | 0.00 | 0.00 |
CORE_MID | 8294.83 | 465.17 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 8330.17 | 429.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 8466.67 | 293.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 8645.33 | 114.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 8533.33 | 226.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 8259.50 | 500.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 8416.83 | 343.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 8468.50 | 291.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 8406.00 | 354.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 8340.33 | 419.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 8480.67 | 279.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 8481.67 | 278.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 8432.00 | 328.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 8381.50 | 378.50 | 0.00 | 0.00 | 0.00 |
DATACENTER_BOT_ZN_6 | 8471.83 | 288.17 | 0.00 | 0.00 | 0.00 |
DATACENTER_MID_ZN_6 | 8458.67 | 301.33 | 0.00 | 0.00 | 0.00 |
DATACENTER_TOP_ZN_6 | 8459.00 | 301.00 | 0.00 | 0.00 | 0.00 |
DATACENTER_BASEMENT_ZN_6 | 8553.83 | 206.17 | 0.00 | 0.00 | 0.00 |
GROUNDFLOOR_PLENUM | 8322.83 | 437.17 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 8387.67 | 372.33 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 8370.50 | 389.50 | 0.00 | 0.00 | 0.00 |
Min | 7859.67 | 114.67 | 0.00 | 0.00 | 0.00 |
Max | 8645.33 | 900.33 | 0.00 | 0.00 | 0.00 |
Average | 8397.50 | 362.50 | 0.00 | 0.00 | 0.00 |
Sum | 193142.50 | 8337.50 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
BASEMENT | 360802.67 | 7813.33 | 0.00 | 0.00 | 0.00 |
CORE_BOTTOM | 329709.00 | 1104.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 329756.33 | 1056.67 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 329849.00 | 964.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 38882.33 | 42.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 24899.00 | 10.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 38885.00 | 40.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 24900.67 | 8.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 38882.00 | 43.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 18350.67 | 3.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 38891.67 | 33.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 24901.50 | 7.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 38903.67 | 21.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 24899.00 | 10.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 38893.00 | 32.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 24899.00 | 10.00 | 0.00 | 0.00 | 0.00 |
DATACENTER_BOT_ZN_6 | 2079.33 | 188.67 | 0.00 | 0.00 | 0.00 |
DATACENTER_MID_ZN_6 | 2071.33 | 196.67 | 0.00 | 0.00 | 0.00 |
DATACENTER_TOP_ZN_6 | 2071.00 | 197.00 | 0.00 | 0.00 | 0.00 |
DATACENTER_BASEMENT_ZN_6 | 98738.50 | 4656.50 | 0.00 | 0.00 | 0.00 |
GROUNDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 360802.67 | 7813.33 | 0.00 | 0.00 | 0.00 |
Average | 79620.20 | 714.71 | 0.00 | 0.00 | 0.00 |
Sum | 1831264.67 | 16438.33 | 0.00 | 0.00 | 0.00 |
SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
None |
SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
CO2 Level HoursSafe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 09:03:35
Illuminance Level HoursA Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
BASEMENT | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_BOTTOM | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
DATACENTER_BOT_ZN_6 | 0.00 | 0.00 | 0.00 | 0.00 |
DATACENTER_MID_ZN_6 | 0.00 | 0.00 | 0.00 | 0.00 |
DATACENTER_TOP_ZN_6 | 0.00 | 0.00 | 0.00 | 0.00 |
DATACENTER_BASEMENT_ZN_6 | 0.00 | 0.00 | 0.00 | 0.00 |
GROUNDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 0.00 | 8760.00 | 0.00 |
Average | 0.00 | 0.00 | 4570.43 | 0.00 |
Sum | 0.00 | 0.00 | 105120.00 | 0.00 |
A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
BASEMENT | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_BOTTOM | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 38925.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 0.00 | 0.00 | 38925.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_MID_ZN_3 | 0.00 | 0.00 | 38925.00 | 0.00 |
PERIMETER_MID_ZN_2 | 0.00 | 0.00 | 18354.00 | 0.00 |
PERIMETER_MID_ZN_1 | 0.00 | 0.00 | 38925.00 | 0.00 |
PERIMETER_MID_ZN_4 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.00 | 0.00 | 38925.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 0.00 | 0.00 | 38925.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 0.00 | 0.00 | 24909.00 | 0.00 |
DATACENTER_BOT_ZN_6 | 0.00 | 0.00 | 0.00 | 0.00 |
DATACENTER_MID_ZN_6 | 0.00 | 0.00 | 0.00 | 0.00 |
DATACENTER_TOP_ZN_6 | 0.00 | 0.00 | 0.00 | 0.00 |
DATACENTER_BASEMENT_ZN_6 | 0.00 | 0.00 | 0.00 | 0.00 |
GROUNDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 0.00 | 38925.00 | 0.00 |
Average | 0.00 | 0.00 | 16367.35 | 0.00 |
Sum | 0.00 | 0.00 | 376449.00 | 0.00 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015
For: Environment
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICELARGE
For: Environment
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 7
For: Environment
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MN_INTERNATIONALFALLS
For: Environment
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: ZoneCoolingSummaryMonthly
For: BASEMENT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.382745E+11 | 104178.04 | 31-JAN-05:19 | -14.4 | -14.7 | 0.538944E+10 | 7502.48 | 02-JAN-14:30 | -14.4 | -14.7 |
February | 0.392742E+11 | 106865.47 | 21-FEB-05:01 | 2.30 | 0.74 | 0.508363E+10 | 7726.18 | 01-FEB-10:09 | 2.30 | 0.74 |
March | 0.490277E+11 | 109759.67 | 20-MAR-03:11 | -7.6 | -7.9 | 0.612576E+10 | 7500.87 | 07-MAR-14:39 | -7.6 | -7.9 |
April | 0.506298E+11 | 109991.31 | 10-APR-03:01 | -1.9 | -3.7 | 0.544540E+10 | 7499.18 | 07-APR-09:09 | -1.9 | -3.7 |
May | 0.563761E+11 | 110756.30 | 22-MAY-03:02 | 6.85 | 3.93 | 0.589967E+10 | 7499.16 | 24-MAY-09:20 | 22.57 | 16.40 |
June | 0.589634E+11 | 109355.83 | 05-JUN-03:02 | 12.62 | 9.70 | 0.588080E+10 | 7499.27 | 06-JUN-13:30 | 23.10 | 15.66 |
July | 0.608320E+11 | 111393.93 | 10-JUL-03:02 | 7.80 | 7.49 | 0.547687E+10 | 7809.47 | 05-JUL-13:09 | 7.80 | 7.49 |
August | 0.684670E+11 | 109632.59 | 25-AUG-03:02 | 8.90 | 8.90 | 0.613833E+10 | 7499.27 | 10-AUG-13:00 | 8.90 | 8.90 |
September | 0.593577E+11 | 111588.94 | 25-SEP-03:02 | 8.80 | 7.89 | 0.545214E+10 | 7499.09 | 06-SEP-09:09 | 8.80 | 7.89 |
October | 0.583444E+11 | 114370.80 | 02-OCT-03:02 | 8.40 | 6.92 | 0.566907E+10 | 7499.29 | 25-OCT-09:00 | 3.30 | 3.04 |
November | 0.525486E+11 | 111988.85 | 20-NOV-04:01 | 5.00 | 4.21 | 0.561005E+10 | 7499.93 | 29-NOV-10:09 | -10.3 | -11.0 |
December | 0.463782E+11 | 107593.78 | 18-DEC-05:01 | -15.2 | -16.2 | 0.538843E+10 | 7532.78 | 18-DEC-16:00 | -23.5 | -24.0 |
Annual Sum or Average | 0.638474E+12 | 0.675596E+11 | ||||||||
Minimum of Months | 0.382745E+11 | 104178.04 | -15.2 | -16.2 | 0.508363E+10 | 7499.09 | -23.5 | -24.0 | ||
Maximum of Months | 0.684670E+11 | 114370.80 | 12.62 | 9.70 | 0.613833E+10 | 7809.47 | 23.10 | 16.40 |
Report: ZoneCoolingSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.287677E+11 | 76561.72 | 20-JAN-06:01 | -6.8 | -7.3 | 0.488244E+10 | 6734.81 | 25-JAN-10:09 | -23.2 | -23.5 |
February | 0.316812E+11 | 85592.28 | 09-FEB-06:01 | -3.2 | -4.5 | 0.456258E+10 | 6913.30 | 28-FEB-10:39 | -3.9 | -5.9 |
March | 0.445403E+11 | 87645.76 | 28-MAR-04:01 | 2.12 | 0.73 | 0.548703E+10 | 6902.14 | 23-MAR-09:50 | 2.12 | 0.73 |
April | 0.512940E+11 | 89366.15 | 25-APR-03:02 | 3.22 | 1.35 | 0.488363E+10 | 6834.32 | 05-APR-09:00 | 3.22 | 1.35 |
May | 0.548131E+11 | 90293.08 | 08-MAY-03:02 | 6.07 | 4.02 | 0.528736E+10 | 6734.88 | 24-MAY-09:09 | 22.38 | 16.32 |
June | 0.608417E+11 | 93567.19 | 19-JUN-03:02 | 17.70 | 16.94 | 0.526955E+10 | 6734.89 | 13-JUN-09:00 | 17.70 | 16.94 |
July | 0.669464E+11 | 91304.82 | 17-JUL-03:02 | 11.02 | 10.74 | 0.490100E+10 | 7082.63 | 05-JUL-13:09 | 11.02 | 10.74 |
August | 0.725041E+11 | 90171.39 | 18-AUG-03:02 | 11.78 | 11.10 | 0.549691E+10 | 6734.81 | 10-AUG-13:30 | 11.78 | 11.10 |
September | 0.510023E+11 | 92616.42 | 11-SEP-03:02 | 11.78 | 10.17 | 0.488206E+10 | 6734.81 | 14-SEP-09:09 | 13.27 | 10.50 |
October | 0.476675E+11 | 92643.40 | 23-OCT-03:02 | 5.60 | 4.54 | 0.507517E+10 | 6781.56 | 12-OCT-13:30 | 5.60 | 4.54 |
November | 0.413190E+11 | 89402.29 | 13-NOV-05:02 | -7.9 | -8.8 | 0.502166E+10 | 6838.55 | 07-NOV-10:20 | -7.9 | -8.8 |
December | 0.354830E+11 | 84677.95 | 29-DEC-06:01 | -16.7 | -17.0 | 0.486509E+10 | 6866.70 | 01-DEC-10:00 | -16.7 | -17.0 |
Annual Sum or Average | 0.586860E+12 | 0.606145E+11 | ||||||||
Minimum of Months | 0.287677E+11 | 76561.72 | -16.7 | -17.0 | 0.456258E+10 | 6734.81 | -23.2 | -23.5 | ||
Maximum of Months | 0.725041E+11 | 93567.19 | 17.70 | 16.94 | 0.549691E+10 | 7082.63 | 22.38 | 16.94 |
Report: ZoneCoolingSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.216269E+11 | 18912.83 | 06-JAN-09:00 | -35.6 | -35.7 | 0.421877E+10 | 6614.65 | 27-JAN-14:00 | -14.4 | -15.6 |
February | 0.225271E+11 | 29255.66 | 08-FEB-11:25 | 1.95 | -2.0 | 0.407797E+10 | 6734.75 | 10-FEB-14:20 | -12.4 | -13.8 |
March | 0.288996E+11 | 72122.85 | 30-MAR-05:03 | -1.9 | -2.1 | 0.519921E+10 | 6820.76 | 22-MAR-13:39 | -1.9 | -2.1 |
April | 0.325065E+11 | 79975.83 | 24-APR-05:02 | 4.40 | 3.41 | 0.479882E+10 | 6790.76 | 28-APR-09:00 | 2.80 | -1.1 |
May | 0.448736E+11 | 89870.18 | 30-MAY-03:02 | 10.60 | 8.25 | 0.527483E+10 | 6885.92 | 01-MAY-09:39 | 10.60 | 8.25 |
June | 0.487497E+11 | 84030.89 | 28-JUN-03:02 | 16.02 | 15.30 | 0.526199E+10 | 6734.85 | 13-JUN-09:00 | 16.02 | 15.30 |
July | 0.495815E+11 | 86919.93 | 05-JUL-03:02 | 19.50 | 18.65 | 0.489712E+10 | 6929.69 | 05-JUL-13:09 | 23.30 | 21.28 |
August | 0.506916E+11 | 83607.20 | 10-AUG-03:02 | 16.02 | 15.69 | 0.548954E+10 | 6734.83 | 10-AUG-13:39 | 19.03 | 16.37 |
September | 0.401798E+11 | 81925.96 | 02-SEP-04:02 | 14.82 | 11.37 | 0.486059E+10 | 6734.79 | 14-SEP-09:09 | 13.27 | 10.50 |
October | 0.322105E+11 | 78417.05 | 20-OCT-05:03 | 7.52 | 7.52 | 0.498758E+10 | 6803.53 | 13-OCT-13:39 | 7.52 | 7.52 |
November | 0.251447E+11 | 68986.30 | 22-NOV-13:50 | -0.2 | -4.1 | 0.471193E+10 | 6787.96 | 22-NOV-13:20 | -0.2 | -4.1 |
December | 0.233071E+11 | 20707.55 | 01-DEC-17:00 | -19.7 | -20.2 | 0.416062E+10 | 6734.06 | 01-DEC-14:00 | -19.7 | -20.2 |
Annual Sum or Average | 0.420299E+12 | 0.579390E+11 | ||||||||
Minimum of Months | 0.216269E+11 | 18912.83 | -35.6 | -35.7 | 0.407797E+10 | 6614.65 | -19.7 | -20.2 | ||
Maximum of Months | 0.506916E+11 | 89870.18 | 19.50 | 18.65 | 0.548954E+10 | 6929.69 | 23.30 | 21.28 |
Report: ZoneCoolingSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.124401E+11 | 16749.52 | 20-JAN-17:00 | -7.2 | -8.4 | 0.386169E+10 | 5908.13 | 20-JAN-14:00 | -7.2 | -8.4 |
February | 0.145826E+11 | 18623.21 | 08-FEB-17:00 | 3.30 | -1.3 | 0.363736E+10 | 6356.21 | 08-FEB-14:00 | 3.30 | -1.3 |
March | 0.208062E+11 | 26745.76 | 29-MAR-16:00 | 5.00 | 1.34 | 0.460862E+10 | 6734.46 | 29-MAR-13:50 | 5.00 | 1.34 |
April | 0.259281E+11 | 41144.84 | 14-APR-05:03 | 2.12 | 1.45 | 0.447655E+10 | 6734.63 | 18-APR-09:39 | 18.13 | 11.06 |
May | 0.406300E+11 | 80624.16 | 25-MAY-04:02 | 17.47 | 13.83 | 0.520857E+10 | 6743.24 | 31-MAY-09:20 | 8.60 | 6.60 |
June | 0.478623E+11 | 82968.74 | 29-JUN-03:02 | 21.78 | 19.19 | 0.524178E+10 | 6734.81 | 13-JUN-09:00 | 21.78 | 19.19 |
July | 0.495426E+11 | 85514.62 | 05-JUL-03:02 | 19.50 | 18.65 | 0.488965E+10 | 7002.93 | 05-JUL-13:09 | 23.30 | 21.28 |
August | 0.483228E+11 | 83052.85 | 09-AUG-03:02 | 19.82 | 18.38 | 0.547311E+10 | 6734.83 | 10-AUG-13:39 | 19.03 | 16.37 |
September | 0.333878E+11 | 80215.46 | 01-SEP-04:02 | 16.02 | 16.02 | 0.478502E+10 | 6734.76 | 14-SEP-09:09 | 13.27 | 10.50 |
October | 0.240147E+11 | 37730.97 | 20-OCT-16:00 | 18.30 | 9.93 | 0.458531E+10 | 6734.73 | 20-OCT-09:09 | 18.30 | 9.93 |
November | 0.185831E+11 | 20712.45 | 17-NOV-17:00 | 6.70 | 1.30 | 0.418230E+10 | 6677.46 | 17-NOV-14:00 | 6.70 | 1.30 |
December | 0.132617E+11 | 16815.32 | 28-DEC-17:00 | -2.4 | -4.0 | 0.376267E+10 | 5978.34 | 28-DEC-14:00 | -2.4 | -4.0 |
Annual Sum or Average | 0.349362E+12 | 0.547126E+11 | ||||||||
Minimum of Months | 0.124401E+11 | 16749.52 | -7.2 | -8.4 | 0.363736E+10 | 5908.13 | -7.2 | -8.4 | ||
Maximum of Months | 0.495426E+11 | 85514.62 | 21.78 | 19.19 | 0.547311E+10 | 7002.93 | 23.30 | 21.28 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.624855E+09 | 2293.05 | 19-JAN-14:20 | -2.8 | -3.6 | 0.473193E+09 | 719.66 | 19-JAN-14:30 | -2.8 | -3.6 |
February | 0.148877E+10 | 3035.95 | 27-FEB-15:10 | -7.8 | -10.1 | 0.454176E+09 | 799.19 | 21-FEB-14:00 | -7.8 | -10.1 |
March | 0.314242E+10 | 4328.44 | 28-MAR-14:00 | 6.10 | 2.91 | 0.592817E+09 | 845.61 | 28-MAR-13:39 | 6.10 | 2.91 |
April | 0.470619E+10 | 6615.29 | 18-APR-14:00 | 17.80 | 10.49 | 0.587234E+09 | 845.62 | 18-APR-09:09 | 17.80 | 10.49 |
May | 0.740193E+10 | 10323.39 | 24-MAY-05:02 | 13.13 | 10.07 | 0.660059E+09 | 845.64 | 24-MAY-09:09 | 22.38 | 16.32 |
June | 0.964968E+10 | 12941.76 | 28-JUN-05:03 | 15.15 | 14.73 | 0.661193E+09 | 846.15 | 28-JUN-13:20 | 30.00 | 21.52 |
July | 0.108056E+11 | 13148.65 | 24-JUL-05:03 | 17.88 | 16.12 | 0.615967E+09 | 917.62 | 05-JUL-13:09 | 17.88 | 16.12 |
August | 0.101398E+11 | 12470.31 | 14-AUG-05:03 | 15.92 | 13.40 | 0.689357E+09 | 845.64 | 10-AUG-13:30 | 15.92 | 13.40 |
September | 0.576103E+10 | 7622.99 | 01-SEP-15:10 | 26.10 | 17.79 | 0.604611E+09 | 845.63 | 11-SEP-13:09 | 18.90 | 14.33 |
October | 0.419189E+10 | 5509.72 | 02-OCT-13:10 | 10.92 | 9.77 | 0.606656E+09 | 845.62 | 10-OCT-13:39 | 7.40 | 6.22 |
November | 0.297849E+10 | 4061.64 | 01-NOV-13:40 | 17.80 | 13.14 | 0.554505E+09 | 845.61 | 01-NOV-13:00 | 17.80 | 13.26 |
December | 0.133269E+10 | 2836.28 | 29-DEC-06:02 | -16.7 | -17.0 | 0.470692E+09 | 760.97 | 06-DEC-14:20 | -16.7 | -17.0 |
Annual Sum or Average | 0.622233E+11 | 0.697046E+10 | ||||||||
Minimum of Months | 0.624855E+09 | 2293.05 | -16.7 | -17.0 | 0.454176E+09 | 719.66 | -16.7 | -17.0 | ||
Maximum of Months | 0.108056E+11 | 13148.65 | 26.10 | 17.79 | 0.689357E+09 | 917.62 | 30.00 | 21.52 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.805248E+09 | 3169.26 | 27-JAN-11:30 | -17.8 | -18.4 | 0.302112E+09 | 458.20 | 25-JAN-10:30 | -17.8 | -18.4 |
February | 0.180790E+10 | 4247.94 | 28-FEB-10:15 | -5.0 | -6.8 | 0.290772E+09 | 547.57 | 28-FEB-10:20 | -5.0 | -6.8 |
March | 0.367280E+10 | 11020.38 | 20-MAR-09:20 | -2.2 | -3.8 | 0.373434E+09 | 561.90 | 23-MAR-09:50 | -6.2 | -7.3 |
April | 0.600904E+10 | 11644.97 | 19-APR-08:20 | 2.97 | -2.4 | 0.368588E+09 | 551.10 | 05-APR-09:00 | 2.97 | -2.4 |
May | 0.779817E+10 | 21862.12 | 21-MAY-08:32 | 11.20 | 6.80 | 0.419966E+09 | 544.98 | 18-MAY-09:50 | 11.20 | 6.80 |
June | 0.950999E+10 | 20174.35 | 25-JUN-07:52 | 23.90 | 20.76 | 0.422302E+09 | 544.98 | 13-JUN-09:50 | 23.90 | 20.76 |
July | 0.106480E+11 | 18232.86 | 23-JUL-09:32 | 26.13 | 22.79 | 0.393775E+09 | 549.94 | 05-JUL-13:09 | 26.13 | 22.79 |
August | 0.936073E+10 | 23011.83 | 20-AUG-08:32 | 19.83 | 15.28 | 0.434190E+09 | 544.97 | 04-AUG-09:00 | 19.83 | 15.28 |
September | 0.633801E+10 | 14263.25 | 10-SEP-09:53 | 15.60 | 10.56 | 0.373488E+09 | 544.97 | 14-SEP-09:09 | 13.27 | 10.50 |
October | 0.461505E+10 | 8633.56 | 19-OCT-09:10 | 11.57 | 8.32 | 0.356075E+09 | 544.96 | 19-OCT-09:00 | 13.90 | 10.03 |
November | 0.292065E+10 | 4467.12 | 10-NOV-12:40 | -3.0 | -5.4 | 0.327255E+09 | 544.95 | 16-NOV-10:09 | 2.15 | -0.3 |
December | 0.100034E+10 | 3762.79 | 07-DEC-06:02 | -7.8 | -8.0 | 0.293240E+09 | 493.41 | 01-DEC-10:30 | -7.8 | -8.0 |
Annual Sum or Average | 0.644859E+11 | 0.435520E+10 | ||||||||
Minimum of Months | 0.805248E+09 | 3169.26 | -17.8 | -18.4 | 0.290772E+09 | 458.20 | -17.8 | -18.4 | ||
Maximum of Months | 0.106480E+11 | 23011.83 | 26.13 | 22.79 | 0.434190E+09 | 561.90 | 26.13 | 22.79 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.281381E+10 | 13002.81 | 27-JAN-13:30 | -15.0 | -16.1 | 0.516470E+09 | 845.65 | 06-JAN-14:09 | -15.0 | -16.1 |
February | 0.468975E+10 | 19055.35 | 27-FEB-15:10 | -7.8 | -10.1 | 0.501060E+09 | 893.20 | 28-FEB-10:39 | -3.9 | -5.9 |
March | 0.685192E+10 | 21664.06 | 17-MAR-13:30 | -3.6 | -6.4 | 0.610226E+09 | 896.31 | 17-MAR-13:20 | -3.6 | -6.4 |
April | 0.929129E+10 | 26552.23 | 23-APR-13:22 | 23.60 | 15.70 | 0.574727E+09 | 866.10 | 04-APR-13:30 | 23.60 | 15.70 |
May | 0.108521E+11 | 23009.26 | 21-MAY-14:32 | 22.23 | 11.38 | 0.650122E+09 | 846.72 | 17-MAY-13:50 | 22.23 | 11.38 |
June | 0.122322E+11 | 17016.62 | 30-JUN-12:40 | 31.70 | 24.34 | 0.655354E+09 | 846.37 | 30-JUN-13:00 | 31.10 | 23.76 |
July | 0.145617E+11 | 27241.38 | 16-JUL-12:52 | 23.90 | 18.44 | 0.612624E+09 | 920.50 | 05-JUL-13:09 | 23.90 | 18.44 |
August | 0.149183E+11 | 28467.08 | 20-AUG-12:32 | 24.80 | 15.76 | 0.684863E+09 | 847.52 | 01-AUG-13:50 | 24.80 | 15.76 |
September | 0.104850E+11 | 27752.06 | 03-SEP-14:32 | 21.50 | 16.23 | 0.592473E+09 | 849.78 | 01-SEP-13:20 | 21.50 | 16.23 |
October | 0.796180E+10 | 30293.41 | 22-OCT-12:41 | 18.03 | 13.00 | 0.578899E+09 | 846.51 | 25-OCT-13:00 | 11.10 | 7.08 |
November | 0.532083E+10 | 22122.08 | 10-NOV-13:00 | -2.8 | -5.4 | 0.547176E+09 | 858.94 | 10-NOV-10:39 | -2.8 | -5.4 |
December | 0.279696E+10 | 10200.56 | 20-DEC-13:30 | -20.9 | -21.5 | 0.489089E+09 | 851.29 | 20-DEC-14:30 | -19.5 | -20.3 |
Annual Sum or Average | 0.102776E+12 | 0.701308E+10 | ||||||||
Minimum of Months | 0.279696E+10 | 10200.56 | -20.9 | -21.5 | 0.489089E+09 | 845.65 | -19.5 | -20.3 | ||
Maximum of Months | 0.149183E+11 | 30293.41 | 31.70 | 24.34 | 0.684863E+09 | 920.50 | 31.10 | 23.76 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.172391E+10 | 4875.13 | 27-JAN-15:40 | -14.4 | -15.6 | 0.309579E+09 | 512.72 | 27-JAN-16:10 | -14.8 | -15.9 |
February | 0.360210E+10 | 8939.21 | 27-FEB-17:10 | -8.0 | -10.4 | 0.305588E+09 | 544.95 | 28-FEB-14:00 | 6.10 | 1.55 |
March | 0.660342E+10 | 19876.97 | 26-MAR-17:12 | 9.63 | 4.75 | 0.398170E+09 | 554.75 | 15-MAR-15:00 | 9.63 | 4.75 |
April | 0.925383E+10 | 28147.12 | 23-APR-16:41 | 26.20 | 16.72 | 0.386785E+09 | 544.95 | 05-APR-13:20 | 26.20 | 16.72 |
May | 0.100798E+11 | 27207.52 | 21-MAY-15:52 | 22.40 | 11.37 | 0.420384E+09 | 544.97 | 16-MAY-13:20 | 22.40 | 11.37 |
June | 0.121084E+11 | 26224.81 | 17-JUN-17:42 | 23.90 | 13.28 | 0.425261E+09 | 544.97 | 13-JUN-09:00 | 23.90 | 13.28 |
July | 0.147522E+11 | 27911.86 | 16-JUL-16:11 | 22.23 | 16.17 | 0.397173E+09 | 552.90 | 05-JUL-13:00 | 22.23 | 16.17 |
August | 0.149488E+11 | 26637.12 | 05-AUG-17:42 | 22.30 | 14.14 | 0.445464E+09 | 544.98 | 10-AUG-13:30 | 18.85 | 16.08 |
September | 0.799988E+10 | 28615.61 | 03-SEP-17:11 | 21.33 | 15.90 | 0.378522E+09 | 544.96 | 11-SEP-13:09 | 18.90 | 14.33 |
October | 0.669271E+10 | 19279.65 | 22-OCT-14:42 | 19.40 | 12.77 | 0.381362E+09 | 544.94 | 02-OCT-13:00 | 19.40 | 12.77 |
November | 0.521400E+10 | 7842.22 | 09-NOV-15:40 | 1.47 | -3.6 | 0.364559E+09 | 544.95 | 10-NOV-14:20 | -1.7 | -4.6 |
December | 0.410950E+10 | 5475.92 | 28-DEC-06:02 | -2.3 | -2.8 | 0.321413E+09 | 543.12 | 28-DEC-14:50 | -1.7 | -3.7 |
Annual Sum or Average | 0.970885E+11 | 0.453426E+10 | ||||||||
Minimum of Months | 0.172391E+10 | 4875.13 | -14.4 | -15.6 | 0.305588E+09 | 512.72 | -14.8 | -15.9 | ||
Maximum of Months | 0.149488E+11 | 28615.61 | 26.20 | 16.72 | 0.445464E+09 | 554.75 | 26.20 | 16.72 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 24231418.81 | 1605.64 | 28-JAN-17:01 | -7.8 | -9.1 | 0.460739E+09 | 626.00 | 04-JAN-10:09 | -7.8 | -9.1 |
February | 0.169232E+09 | 2352.43 | 08-FEB-17:05 | 2.93 | -1.5 | 0.421366E+09 | 645.53 | 08-FEB-14:50 | 2.93 | -1.5 |
March | 0.988333E+09 | 4139.78 | 10-MAR-14:33 | -0.6 | -2.9 | 0.520927E+09 | 758.52 | 28-MAR-13:00 | 6.10 | 2.91 |
April | 0.252650E+10 | 4666.71 | 05-APR-12:58 | -1.1 | -5.0 | 0.517490E+09 | 845.60 | 18-APR-13:00 | 17.80 | 10.49 |
May | 0.586112E+10 | 8975.05 | 24-MAY-05:02 | 13.13 | 10.07 | 0.647369E+09 | 845.64 | 24-MAY-09:09 | 22.38 | 16.32 |
June | 0.782825E+10 | 12151.02 | 30-JUN-03:02 | 25.68 | 23.15 | 0.658937E+09 | 845.91 | 28-JUN-13:39 | 25.68 | 23.15 |
July | 0.826038E+10 | 11638.17 | 01-JUL-05:02 | 9.78 | 9.47 | 0.615077E+09 | 904.12 | 05-JUL-13:09 | 23.30 | 21.28 |
August | 0.694486E+10 | 8260.85 | 09-AUG-15:30 | 27.25 | 21.19 | 0.684546E+09 | 845.64 | 10-AUG-13:39 | 19.03 | 16.37 |
September | 0.416791E+10 | 6907.14 | 01-SEP-15:40 | 26.10 | 17.70 | 0.583198E+09 | 845.63 | 11-SEP-13:09 | 18.90 | 14.33 |
October | 0.253747E+10 | 4122.91 | 13-OCT-12:58 | 1.10 | -0.5 | 0.528380E+09 | 845.60 | 02-OCT-13:00 | 1.10 | -0.5 |
November | 0.893636E+09 | 3782.55 | 02-NOV-08:50 | 2.98 | 2.45 | 0.472587E+09 | 768.84 | 01-NOV-13:00 | 2.98 | 2.45 |
December | 38061910.96 | 1624.36 | 30-DEC-17:02 | -3.3 | -3.3 | 0.445747E+09 | 625.99 | 19-DEC-10:00 | -3.3 | -3.3 |
Annual Sum or Average | 0.402400E+11 | 0.655636E+10 | ||||||||
Minimum of Months | 24231418.81 | 1605.64 | -7.8 | -9.1 | 0.421366E+09 | 625.99 | -7.8 | -9.1 | ||
Maximum of Months | 0.826038E+10 | 12151.02 | 27.25 | 23.15 | 0.684546E+09 | 904.12 | 25.68 | 23.15 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 64293916.63 | 2646.04 | 11-JAN-06:04 | -25.4 | -25.5 | 0.218626E+09 | 385.85 | 04-JAN-09:00 | -25.4 | -25.5 |
February | 0.483169E+09 | 5096.76 | 08-FEB-11:25 | 1.95 | -2.0 | 0.199634E+09 | 438.04 | 08-FEB-11:20 | 1.95 | -2.0 |
March | 0.193788E+10 | 7338.76 | 31-MAR-10:15 | 2.43 | -0.4 | 0.252361E+09 | 556.30 | 23-MAR-10:00 | 2.43 | -0.4 |
April | 0.444585E+10 | 10982.86 | 19-APR-08:40 | 3.13 | -2.4 | 0.255153E+09 | 532.81 | 12-APR-07:40 | 3.13 | -2.4 |
May | 0.727065E+10 | 22949.77 | 21-MAY-09:02 | 12.52 | 7.56 | 0.300279E+09 | 534.41 | 01-MAY-08:09 | 12.52 | 7.56 |
June | 0.905378E+10 | 23969.75 | 18-JUN-08:62 | 19.78 | 12.83 | 0.307342E+09 | 521.66 | 28-JUN-08:39 | 26.47 | 21.10 |
July | 0.963940E+10 | 22371.50 | 23-JUL-09:32 | 26.13 | 22.79 | 0.289638E+09 | 528.31 | 05-JUL-10:00 | 26.13 | 22.79 |
August | 0.799055E+10 | 20340.47 | 20-AUG-09:22 | 21.70 | 15.75 | 0.311770E+09 | 521.25 | 21-AUG-07:10 | 15.97 | 15.14 |
September | 0.559086E+10 | 17399.39 | 10-SEP-09:02 | 13.68 | 10.14 | 0.258851E+09 | 521.21 | 13-SEP-10:20 | 15.33 | 11.11 |
October | 0.298743E+10 | 6881.30 | 19-OCT-08:55 | 11.10 | 7.97 | 0.236031E+09 | 521.21 | 19-OCT-10:09 | 14.27 | 10.24 |
November | 0.102696E+10 | 3545.50 | 22-NOV-13:50 | -0.2 | -4.1 | 0.220220E+09 | 465.81 | 16-NOV-09:00 | -0.2 | -4.1 |
December | 72334071.13 | 2654.39 | 28-DEC-06:04 | -2.3 | -2.8 | 0.210997E+09 | 385.83 | 29-DEC-09:09 | -15.9 | -16.4 |
Annual Sum or Average | 0.505632E+11 | 0.306090E+10 | ||||||||
Minimum of Months | 64293916.63 | 2646.04 | -25.4 | -25.5 | 0.199634E+09 | 385.83 | -25.4 | -25.5 | ||
Maximum of Months | 0.963940E+10 | 23969.75 | 26.13 | 22.79 | 0.311770E+09 | 556.30 | 26.47 | 22.79 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.196173E+10 | 12976.16 | 27-JAN-13:40 | -14.8 | -15.9 | 0.498997E+09 | 845.65 | 06-JAN-14:09 | -14.8 | -15.9 |
February | 0.374554E+10 | 17662.03 | 28-FEB-13:40 | 3.33 | -0.5 | 0.478068E+09 | 846.09 | 22-FEB-14:09 | 3.33 | -0.5 |
March | 0.529624E+10 | 27113.22 | 19-MAR-13:32 | 3.70 | 0.68 | 0.583032E+09 | 885.61 | 23-MAR-10:00 | -2.8 | -5.6 |
April | 0.750849E+10 | 27093.75 | 23-APR-14:02 | 24.60 | 16.15 | 0.549525E+09 | 846.26 | 13-APR-13:00 | 24.60 | 16.15 |
May | 0.100334E+11 | 26052.53 | 21-MAY-15:02 | 22.73 | 11.45 | 0.639231E+09 | 846.87 | 24-MAY-13:00 | 27.10 | 17.69 |
June | 0.109276E+11 | 26596.89 | 18-JUN-14:02 | 26.60 | 18.72 | 0.648127E+09 | 846.20 | 30-JUN-13:00 | 31.10 | 23.76 |
July | 0.122349E+11 | 27878.28 | 16-JUL-14:12 | 24.23 | 18.32 | 0.609510E+09 | 902.71 | 05-JUL-13:09 | 24.23 | 18.32 |
August | 0.122484E+11 | 27002.15 | 13-AUG-13:32 | 23.13 | 14.35 | 0.673685E+09 | 847.02 | 01-AUG-13:50 | 23.13 | 14.35 |
September | 0.983921E+10 | 28523.55 | 03-SEP-14:32 | 21.50 | 16.23 | 0.574795E+09 | 876.62 | 01-SEP-13:39 | 21.50 | 16.23 |
October | 0.679785E+10 | 28905.87 | 22-OCT-13:02 | 18.48 | 13.04 | 0.544550E+09 | 845.91 | 25-OCT-13:00 | 11.10 | 7.08 |
November | 0.351138E+10 | 19140.22 | 07-NOV-13:07 | -1.5 | -4.9 | 0.510724E+09 | 858.94 | 16-NOV-10:39 | 3.50 | 0.38 |
December | 0.123122E+10 | 8084.94 | 02-DEC-13:30 | -18.6 | -19.3 | 0.467864E+09 | 845.65 | 20-DEC-14:09 | -20.0 | -20.7 |
Annual Sum or Average | 0.853360E+11 | 0.677811E+10 | ||||||||
Minimum of Months | 0.123122E+10 | 8084.94 | -18.6 | -19.3 | 0.467864E+09 | 845.65 | -20.0 | -20.7 | ||
Maximum of Months | 0.122484E+11 | 28905.87 | 26.60 | 18.72 | 0.673685E+09 | 902.71 | 31.10 | 23.76 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.281922E+09 | 3336.64 | 27-JAN-16:00 | -14.4 | -15.6 | 0.299992E+09 | 441.40 | 27-JAN-16:10 | -14.8 | -15.9 |
February | 0.892806E+09 | 5075.68 | 22-FEB-15:57 | -0.6 | -3.9 | 0.277836E+09 | 521.18 | 08-FEB-16:00 | -0.6 | -3.9 |
March | 0.235928E+10 | 11756.98 | 10-MAR-16:00 | 0.00 | -2.8 | 0.340911E+09 | 547.77 | 10-MAR-15:30 | 0.00 | -2.8 |
April | 0.473133E+10 | 24826.96 | 23-APR-16:41 | 26.20 | 16.72 | 0.326749E+09 | 544.93 | 18-APR-13:00 | 26.20 | 16.72 |
May | 0.801700E+10 | 26418.68 | 14-MAY-17:21 | 20.00 | 8.49 | 0.399695E+09 | 544.96 | 16-MAY-13:09 | 24.58 | 15.35 |
June | 0.894912E+10 | 24105.14 | 17-JUN-17:42 | 23.90 | 13.28 | 0.411563E+09 | 544.96 | 07-JUN-13:00 | 23.90 | 13.28 |
July | 0.976507E+10 | 26189.28 | 04-JUL-16:31 | 24.63 | 19.94 | 0.390089E+09 | 550.65 | 05-JUL-13:00 | 23.30 | 20.61 |
August | 0.872106E+10 | 23924.69 | 05-AUG-17:42 | 22.30 | 14.14 | 0.424748E+09 | 544.97 | 10-AUG-13:39 | 19.03 | 16.37 |
September | 0.590034E+10 | 25990.64 | 03-SEP-17:11 | 21.33 | 15.90 | 0.345817E+09 | 544.94 | 07-SEP-13:00 | 23.90 | 14.48 |
October | 0.362830E+10 | 8591.55 | 19-OCT-16:00 | 21.70 | 13.55 | 0.324863E+09 | 521.18 | 06-OCT-15:00 | 21.70 | 13.55 |
November | 0.137407E+10 | 5766.63 | 09-NOV-16:45 | -0.3 | -4.5 | 0.303019E+09 | 492.02 | 17-NOV-15:50 | 10.10 | 3.24 |
December | 0.211665E+09 | 2836.94 | 06-DEC-06:03 | -0.8 | -0.8 | 0.288509E+09 | 403.40 | 14-DEC-10:20 | -22.0 | -22.3 |
Annual Sum or Average | 0.548320E+11 | 0.413379E+10 | ||||||||
Minimum of Months | 0.211665E+09 | 2836.94 | -14.4 | -15.6 | 0.277836E+09 | 403.40 | -22.0 | -22.3 | ||
Maximum of Months | 0.976507E+10 | 26418.68 | 26.20 | 19.94 | 0.424748E+09 | 550.65 | 26.20 | 20.61 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 12148737.85 | 2051.10 | 28-JAN-17:01 | -7.8 | -9.1 | 0.458567E+09 | 626.05 | 13-JAN-10:39 | -7.8 | -9.1 |
February | 61410939.21 | 2091.63 | 04-FEB-17:02 | 6.83 | 1.98 | 0.419242E+09 | 626.01 | 13-FEB-10:39 | -23.5 | -24.0 |
March | 0.436060E+09 | 2939.90 | 28-MAR-15:40 | 7.03 | 3.18 | 0.506837E+09 | 681.44 | 29-MAR-13:00 | 3.90 | 0.86 |
April | 0.191432E+10 | 4416.45 | 23-APR-17:11 | 25.93 | 16.61 | 0.478790E+09 | 836.87 | 18-APR-13:00 | 25.93 | 16.61 |
May | 0.570352E+10 | 8623.29 | 24-MAY-14:30 | 27.45 | 17.67 | 0.617711E+09 | 845.64 | 24-MAY-09:09 | 27.45 | 17.67 |
June | 0.789371E+10 | 14312.70 | 28-JUN-05:03 | 15.15 | 14.73 | 0.649943E+09 | 845.65 | 26-JUN-13:20 | 15.15 | 14.73 |
July | 0.844414E+10 | 11409.09 | 21-JUL-05:03 | 17.98 | 17.55 | 0.610628E+09 | 849.76 | 05-JUL-13:09 | 17.98 | 17.55 |
August | 0.699072E+10 | 8839.50 | 09-AUG-15:30 | 27.25 | 21.19 | 0.668387E+09 | 845.64 | 10-AUG-13:39 | 19.03 | 16.37 |
September | 0.395702E+10 | 7388.52 | 01-SEP-15:40 | 26.10 | 17.70 | 0.536688E+09 | 845.62 | 11-SEP-13:00 | 18.90 | 14.76 |
October | 0.163628E+10 | 3657.15 | 20-OCT-13:20 | 18.50 | 9.88 | 0.482682E+09 | 771.59 | 20-OCT-13:00 | 18.90 | 10.07 |
November | 0.356634E+09 | 2700.29 | 01-NOV-16:00 | 17.80 | 13.26 | 0.460280E+09 | 682.99 | 01-NOV-13:00 | 17.80 | 13.26 |
December | 16527458.44 | 2086.46 | 30-DEC-17:02 | -3.3 | -3.3 | 0.443866E+09 | 626.03 | 19-DEC-10:09 | -3.3 | -3.3 |
Annual Sum or Average | 0.374225E+11 | 0.633362E+10 | ||||||||
Minimum of Months | 12148737.85 | 2051.10 | -7.8 | -9.1 | 0.419242E+09 | 626.01 | -23.5 | -24.0 | ||
Maximum of Months | 0.844414E+10 | 14312.70 | 27.45 | 21.19 | 0.668387E+09 | 849.76 | 27.45 | 17.67 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 18378369.98 | 2725.55 | 19-JAN-06:04 | -3.3 | -3.7 | 0.298339E+09 | 403.45 | 04-JAN-10:20 | -3.3 | -3.7 |
February | 0.234932E+09 | 2783.01 | 28-FEB-10:30 | -4.4 | -6.4 | 0.271326E+09 | 424.77 | 28-FEB-10:39 | -3.9 | -5.9 |
March | 0.117059E+10 | 3883.70 | 31-MAR-10:15 | 2.43 | -0.4 | 0.336380E+09 | 531.23 | 31-MAR-09:00 | 2.43 | -0.4 |
April | 0.347341E+10 | 9867.83 | 18-APR-09:30 | 18.05 | 10.95 | 0.338479E+09 | 544.96 | 18-APR-09:00 | 18.30 | 11.28 |
May | 0.675109E+10 | 13203.55 | 18-MAY-09:20 | 24.33 | 15.92 | 0.402867E+09 | 544.98 | 24-MAY-09:09 | 22.38 | 16.32 |
June | 0.895140E+10 | 24552.14 | 18-JUN-09:51 | 23.30 | 16.38 | 0.417298E+09 | 545.79 | 28-JUN-09:50 | 28.62 | 21.85 |
July | 0.970649E+10 | 22667.25 | 23-JUL-09:32 | 26.13 | 22.79 | 0.392963E+09 | 546.78 | 05-JUL-13:09 | 26.13 | 22.79 |
August | 0.777989E+10 | 23566.81 | 20-AUG-09:42 | 22.43 | 15.92 | 0.422224E+09 | 544.97 | 04-AUG-09:00 | 22.43 | 15.92 |
September | 0.477870E+10 | 11999.55 | 01-SEP-09:20 | 20.57 | 17.76 | 0.345149E+09 | 544.96 | 14-SEP-09:09 | 13.27 | 10.50 |
October | 0.181770E+10 | 5725.17 | 19-OCT-09:40 | 12.97 | 9.35 | 0.314106E+09 | 544.95 | 19-OCT-09:00 | 13.90 | 10.03 |
November | 0.496599E+09 | 2906.70 | 16-NOV-10:05 | 2.15 | -0.3 | 0.296575E+09 | 435.86 | 16-NOV-10:20 | 2.60 | 0.02 |
December | 25791771.04 | 2627.72 | 06-DEC-06:04 | -0.8 | -0.8 | 0.287725E+09 | 403.45 | 19-DEC-10:00 | -24.2 | -24.7 |
Annual Sum or Average | 0.452050E+11 | 0.412343E+10 | ||||||||
Minimum of Months | 18378369.98 | 2627.72 | -4.4 | -6.4 | 0.271326E+09 | 403.45 | -24.2 | -24.7 | ||
Maximum of Months | 0.970649E+10 | 24552.14 | 26.13 | 22.79 | 0.422224E+09 | 546.78 | 28.62 | 22.79 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.130880E+10 | 9805.64 | 27-JAN-14:10 | -14.4 | -15.6 | 0.485769E+09 | 845.63 | 25-JAN-14:30 | -14.4 | -15.6 |
February | 0.276876E+10 | 16208.72 | 28-FEB-14:10 | 4.27 | 0.38 | 0.462076E+09 | 845.65 | 14-FEB-14:50 | 4.27 | 0.38 |
March | 0.373203E+10 | 16618.94 | 23-MAR-14:00 | 0.00 | -4.3 | 0.561643E+09 | 845.65 | 20-MAR-13:00 | 0.00 | -4.3 |
April | 0.602105E+10 | 28908.70 | 23-APR-14:31 | 25.20 | 16.35 | 0.529526E+09 | 846.18 | 13-APR-13:00 | 25.20 | 16.35 |
May | 0.939937E+10 | 18698.55 | 18-MAY-13:20 | 28.30 | 16.75 | 0.620072E+09 | 847.07 | 24-MAY-13:00 | 27.10 | 17.69 |
June | 0.108671E+11 | 28728.46 | 18-JUN-13:12 | 26.30 | 18.09 | 0.638144E+09 | 846.46 | 28-JUN-13:00 | 30.00 | 21.52 |
July | 0.123353E+11 | 28921.25 | 23-JUL-13:32 | 30.00 | 22.59 | 0.603998E+09 | 884.37 | 05-JUL-13:20 | 30.00 | 22.59 |
August | 0.120013E+11 | 30653.00 | 13-AUG-13:22 | 23.05 | 14.31 | 0.661568E+09 | 846.98 | 22-AUG-13:50 | 24.32 | 16.45 |
September | 0.874695E+10 | 28658.80 | 04-SEP-12:52 | 16.10 | 9.74 | 0.551114E+09 | 863.77 | 01-SEP-13:39 | 16.10 | 9.74 |
October | 0.501770E+10 | 31560.31 | 22-OCT-14:11 | 19.40 | 12.77 | 0.516439E+09 | 845.83 | 20-OCT-13:00 | 19.40 | 12.77 |
November | 0.234565E+10 | 13654.91 | 17-NOV-13:30 | 10.30 | 3.32 | 0.493351E+09 | 845.64 | 10-NOV-14:20 | 10.30 | 3.32 |
December | 0.748491E+09 | 4916.93 | 20-DEC-14:10 | -20.0 | -20.7 | 0.456618E+09 | 831.64 | 20-DEC-14:20 | -19.8 | -20.5 |
Annual Sum or Average | 0.752925E+11 | 0.658032E+10 | ||||||||
Minimum of Months | 0.748491E+09 | 4916.93 | -20.0 | -20.7 | 0.456618E+09 | 831.64 | -19.8 | -20.5 | ||
Maximum of Months | 0.123353E+11 | 31560.31 | 30.00 | 22.59 | 0.661568E+09 | 884.37 | 30.00 | 22.59 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.161765E+09 | 3066.13 | 27-JAN-15:55 | -14.4 | -15.6 | 0.298610E+09 | 404.93 | 27-JAN-16:10 | -14.8 | -15.9 |
February | 0.593111E+09 | 4296.69 | 08-FEB-16:40 | 3.67 | -1.2 | 0.275127E+09 | 511.47 | 08-FEB-16:49 | 3.48 | -1.2 |
March | 0.156079E+10 | 7921.10 | 28-MAR-17:00 | 7.20 | 3.52 | 0.335256E+09 | 521.19 | 17-MAR-15:00 | 7.20 | 3.52 |
April | 0.379674E+10 | 26473.60 | 23-APR-17:11 | 25.93 | 16.61 | 0.315285E+09 | 544.81 | 18-APR-13:00 | 25.93 | 16.61 |
May | 0.762999E+10 | 27158.40 | 14-MAY-17:21 | 20.00 | 8.49 | 0.386995E+09 | 544.97 | 23-MAY-13:50 | 25.63 | 17.00 |
June | 0.891932E+10 | 25230.92 | 17-JUN-17:42 | 23.90 | 13.28 | 0.404006E+09 | 544.97 | 26-JUN-13:20 | 25.97 | 17.06 |
July | 0.982560E+10 | 27484.94 | 04-JUL-16:31 | 24.63 | 19.94 | 0.385391E+09 | 546.98 | 05-JUL-13:09 | 23.30 | 21.28 |
August | 0.855404E+10 | 25015.95 | 05-AUG-17:42 | 22.30 | 14.14 | 0.415336E+09 | 544.97 | 10-AUG-13:30 | 18.85 | 16.08 |
September | 0.518222E+10 | 20356.82 | 03-SEP-17:22 | 21.15 | 15.79 | 0.331256E+09 | 544.92 | 07-SEP-13:00 | 23.90 | 14.48 |
October | 0.247140E+10 | 8435.89 | 19-OCT-16:00 | 21.70 | 13.55 | 0.314998E+09 | 521.18 | 19-OCT-15:00 | 21.70 | 13.55 |
November | 0.753302E+09 | 3744.42 | 17-NOV-15:40 | 10.20 | 3.28 | 0.298671E+09 | 462.23 | 17-NOV-15:50 | 10.10 | 3.24 |
December | 78589595.73 | 3021.10 | 28-DEC-06:04 | -2.3 | -2.8 | 0.287905E+09 | 403.43 | 18-DEC-10:50 | -2.3 | -2.8 |
Annual Sum or Average | 0.495269E+11 | 0.404884E+10 | ||||||||
Minimum of Months | 78589595.73 | 3021.10 | -14.4 | -15.6 | 0.275127E+09 | 403.43 | -14.8 | -15.9 | ||
Maximum of Months | 0.982560E+10 | 27484.94 | 25.93 | 19.94 | 0.415336E+09 | 546.98 | 25.97 | 21.28 |
Report: ZoneCoolingSummaryMonthly
For: GROUNDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 79114804.07 | 5094.36 | 23-JAN-05:01 | -22.8 | -23.0 | 0.00 | 0.00 | 01-JAN-00:10 | -22.8 | -23.0 |
February | 0.349067E+09 | 5504.10 | 13-FEB-05:01 | -23.4 | -23.8 | 0.00 | 0.00 | 01-FEB-00:10 | -23.4 | -23.8 |
March | 0.140591E+10 | 4850.01 | 27-MAR-05:08 | -3.9 | -4.1 | 0.00 | 0.00 | 01-MAR-00:10 | -3.9 | -4.1 |
April | 0.379495E+10 | 6059.24 | 24-APR-05:15 | 4.40 | 3.41 | 0.00 | 0.00 | 01-APR-00:10 | 4.40 | 3.41 |
May | 0.641237E+10 | 9325.07 | 30-MAY-05:15 | 10.60 | 8.25 | 0.00 | 0.00 | 01-MAY-00:10 | 10.60 | 8.25 |
June | 0.825792E+10 | 8456.34 | 30-JUN-15:50 | 31.78 | 24.63 | 0.00 | 0.00 | 01-JUN-00:10 | 31.78 | 24.63 |
July | 0.944191E+10 | 11292.35 | 17-JUL-05:13 | 12.07 | 11.43 | 0.00 | 0.00 | 01-JUL-00:10 | 12.07 | 11.43 |
August | 0.909561E+10 | 10779.65 | 14-AUG-05:13 | 15.73 | 13.37 | 0.00 | 0.00 | 01-AUG-00:10 | 15.73 | 13.37 |
September | 0.563684E+10 | 8025.40 | 06-SEP-05:03 | 1.28 | 1.24 | 0.00 | 0.00 | 01-SEP-00:10 | 1.28 | 1.24 |
October | 0.363668E+10 | 7862.61 | 23-OCT-05:13 | 5.60 | 4.15 | 0.00 | 0.00 | 01-OCT-00:10 | 5.60 | 4.15 |
November | 0.152889E+10 | 5049.79 | 15-NOV-06:08 | -1.4 | -1.4 | 0.00 | 0.00 | 01-NOV-00:10 | -1.4 | -1.4 |
December | 0.207579E+09 | 3942.75 | 02-DEC-06:01 | -27.7 | -27.9 | 0.00 | 0.00 | 01-DEC-00:10 | -27.7 | -27.9 |
Annual Sum or Average | 0.498468E+11 | 0.00 | ||||||||
Minimum of Months | 79114804.07 | 3942.75 | -27.7 | -27.9 | 0.00 | 0.00 | -27.7 | -27.9 | ||
Maximum of Months | 0.944191E+10 | 11292.35 | 31.78 | 24.63 | 0.00 | 0.00 | 31.78 | 24.63 |
Report: ZoneCoolingSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.428130E+09 | 7386.56 | 13-JAN-04:01 | -30.0 | -30.1 | 0.00 | 0.00 | 01-JAN-00:10 | -30.0 | -30.1 |
February | 0.391121E+09 | 8753.12 | 25-FEB-04:01 | -27.5 | -27.7 | 0.00 | 0.00 | 01-FEB-00:10 | -27.5 | -27.7 |
March | 0.457866E+09 | 7111.04 | 06-MAR-04:11 | -17.6 | -17.9 | 0.00 | 0.00 | 01-MAR-00:10 | -17.6 | -17.9 |
April | 0.173683E+10 | 6215.96 | 03-APR-04:01 | -5.4 | -6.8 | 0.00 | 0.00 | 01-APR-00:10 | -5.4 | -6.8 |
May | 0.465928E+10 | 8066.10 | 30-MAY-05:15 | 10.60 | 8.25 | 0.00 | 0.00 | 01-MAY-00:10 | 10.60 | 8.25 |
June | 0.636474E+10 | 7900.65 | 28-JUN-05:15 | 15.90 | 15.35 | 0.00 | 0.00 | 01-JUN-00:10 | 15.90 | 15.35 |
July | 0.731488E+10 | 8051.92 | 21-JUL-05:15 | 18.17 | 17.73 | 0.00 | 0.00 | 01-JUL-00:10 | 18.17 | 17.73 |
August | 0.643918E+10 | 7581.73 | 10-AUG-05:13 | 15.40 | 14.79 | 0.00 | 0.00 | 01-AUG-00:10 | 15.40 | 14.79 |
September | 0.402154E+10 | 6961.42 | 02-SEP-05:13 | 13.70 | 10.55 | 0.00 | 0.00 | 01-SEP-00:10 | 13.70 | 10.55 |
October | 0.181746E+10 | 6295.08 | 30-OCT-04:01 | -10.0 | -10.7 | 0.00 | 0.00 | 01-OCT-00:10 | -10.0 | -10.7 |
November | 0.524038E+09 | 9340.56 | 24-NOV-04:01 | -11.0 | -11.5 | 0.00 | 0.00 | 01-NOV-00:10 | -11.0 | -11.5 |
December | 0.505072E+09 | 9653.30 | 02-DEC-04:01 | -26.8 | -27.0 | 0.00 | 0.00 | 01-DEC-00:10 | -26.8 | -27.0 |
Annual Sum or Average | 0.346601E+11 | 0.00 | ||||||||
Minimum of Months | 0.391121E+09 | 6215.96 | -30.0 | -30.1 | 0.00 | 0.00 | -30.0 | -30.1 | ||
Maximum of Months | 0.731488E+10 | 9653.30 | 18.17 | 17.73 | 0.00 | 0.00 | 18.17 | 17.73 |
Report: ZoneCoolingSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:01 | -21.9 | -22.1 | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 |
February | 0.00 | 0.00 | 01-FEB-00:03 | -23.1 | -23.5 | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 | -23.5 |
March | 85907230.76 | 2122.83 | 31-MAR-15:20 | 8.50 | 3.01 | 0.00 | 0.00 | 01-MAR-00:10 | 8.50 | 3.01 |
April | 0.171192E+10 | 8725.17 | 13-APR-14:40 | 19.63 | 7.88 | 0.00 | 0.00 | 01-APR-00:10 | 19.63 | 7.88 |
May | 0.650390E+10 | 17176.80 | 18-MAY-14:30 | 28.70 | 16.68 | 0.00 | 0.00 | 01-MAY-00:10 | 28.70 | 16.68 |
June | 0.955827E+10 | 19784.66 | 30-JUN-14:50 | 32.02 | 24.38 | 0.00 | 0.00 | 01-JUN-00:10 | 32.02 | 24.38 |
July | 0.109437E+11 | 18308.22 | 24-JUL-14:40 | 29.40 | 19.47 | 0.00 | 0.00 | 01-JUL-00:10 | 29.40 | 19.47 |
August | 0.825132E+10 | 16487.52 | 08-AUG-15:10 | 30.60 | 23.30 | 0.00 | 0.00 | 01-AUG-00:10 | 30.60 | 23.30 |
September | 0.345445E+10 | 13878.58 | 01-SEP-16:00 | 26.10 | 17.64 | 0.00 | 0.00 | 01-SEP-00:10 | 26.10 | 17.64 |
October | 0.669680E+09 | 6037.75 | 20-OCT-13:30 | 18.60 | 9.93 | 0.00 | 0.00 | 01-OCT-00:10 | 18.60 | 9.93 |
November | 24615630.59 | 2142.22 | 01-NOV-16:30 | 17.25 | 13.03 | 0.00 | 0.00 | 01-NOV-00:10 | 17.25 | 13.03 |
December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 |
Annual Sum or Average | 0.412037E+11 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | -23.1 | -23.5 | 0.00 | 0.00 | -23.1 | -23.5 | ||
Maximum of Months | 0.109437E+11 | 19784.66 | 32.02 | 24.38 | 0.00 | 0.00 | 32.02 | 24.38 |
Report: ZoneCoolingSummaryMonthly
For: DATACENTER_BOT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.151738E+10 | 2021.50 | 25-JAN-16:30 | -18.4 | -19.1 | 95007859.61 | 126.82 | 30-JAN-14:00 | -6.1 | -7.2 |
February | 0.692774E+10 | 4426.89 | 27-FEB-16:55 | -7.8 | -10.2 | 86396456.78 | 126.82 | 23-FEB-14:09 | -7.8 | -10.2 |
March | 0.136200E+11 | 7065.95 | 31-MAR-24:00 | 3.60 | 0.45 | 0.103236E+09 | 126.82 | 30-MAR-13:09 | 3.60 | 0.45 |
April | 0.187674E+11 | 8474.57 | 21-APR-18:10 | 10.82 | 2.42 | 91610395.77 | 126.82 | 26-APR-13:09 | 0.00 | -0.5 |
May | 0.454756E+10 | 3290.74 | 31-MAY-24:00 | 11.20 | 9.10 | 99236320.40 | 126.85 | 26-MAY-13:00 | 11.20 | 9.10 |
June | 0.939753E+10 | 5371.42 | 30-JUN-23:23 | 16.85 | 13.54 | 98967202.41 | 126.86 | 30-JUN-09:20 | 16.85 | 13.54 |
July | 0.148441E+11 | 7252.94 | 31-JUL-23:42 | 16.95 | 15.06 | 91888296.03 | 126.84 | 05-JUL-09:00 | 16.95 | 15.06 |
August | 0.198159E+11 | 8358.72 | 13-AUG-18:40 | 21.13 | 14.84 | 0.103240E+09 | 126.83 | 31-AUG-09:09 | 18.40 | 17.58 |
September | 0.421526E+10 | 3324.65 | 30-SEP-24:00 | 7.80 | 6.76 | 91608637.89 | 126.85 | 01-SEP-09:00 | 7.80 | 6.76 |
October | 0.900008E+10 | 4868.26 | 31-OCT-24:00 | 3.30 | -0.4 | 95230346.40 | 126.83 | 02-OCT-13:00 | 3.30 | -0.4 |
November | 0.131178E+11 | 6042.23 | 09-NOV-16:10 | 0.82 | -3.8 | 94300526.02 | 126.84 | 21-NOV-14:39 | 11.87 | 10.94 |
December | 0.177931E+11 | 7630.57 | 20-DEC-16:00 | -20.2 | -20.8 | 91880855.45 | 126.82 | 01-DEC-10:09 | -20.2 | -20.8 |
Annual Sum or Average | 0.133564E+12 | 0.114260E+10 | ||||||||
Minimum of Months | 0.151738E+10 | 2021.50 | -20.2 | -20.8 | 86396456.78 | 126.82 | -20.2 | -20.8 | ||
Maximum of Months | 0.198159E+11 | 8474.57 | 21.13 | 15.06 | 0.103240E+09 | 126.86 | 18.40 | 17.58 |
Report: ZoneCoolingSummaryMonthly
For: DATACENTER_MID_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.461431E+09 | 1610.46 | 27-JAN-16:25 | -15.6 | -16.5 | 90111128.85 | 126.82 | 19-JAN-14:20 | -15.6 | -16.5 |
February | 0.423437E+10 | 3795.05 | 08-FEB-17:00 | 3.30 | -1.3 | 86396470.61 | 126.82 | 23-FEB-14:09 | -5.8 | -7.7 |
March | 0.110303E+11 | 6326.88 | 31-MAR-23:30 | 3.85 | 0.59 | 0.103236E+09 | 126.82 | 30-MAR-13:09 | 3.85 | 0.59 |
April | 0.166516E+11 | 8068.09 | 21-APR-18:10 | 10.82 | 2.42 | 91606703.18 | 126.82 | 26-APR-13:09 | 0.00 | -0.5 |
May | 0.388602E+10 | 2904.15 | 31-MAY-24:00 | 11.20 | 9.10 | 99235983.19 | 126.85 | 26-MAY-09:00 | 11.20 | 9.10 |
June | 0.866223E+10 | 5271.58 | 30-JUN-23:55 | 16.10 | 13.43 | 98967060.91 | 126.86 | 30-JUN-13:00 | 16.10 | 13.43 |
July | 0.140745E+11 | 6926.61 | 31-JUL-23:55 | 17.00 | 15.17 | 91889227.51 | 126.85 | 05-JUL-09:00 | 17.00 | 15.17 |
August | 0.186638E+11 | 7962.87 | 02-AUG-18:40 | 18.53 | 13.51 | 0.103240E+09 | 126.83 | 28-AUG-13:39 | 20.60 | 18.71 |
September | 0.331302E+10 | 2880.93 | 30-SEP-23:50 | 8.08 | 7.07 | 91607143.62 | 126.84 | 01-SEP-13:00 | 8.08 | 7.07 |
October | 0.709813E+10 | 3997.73 | 18-OCT-16:50 | 15.28 | 10.42 | 95230309.92 | 126.83 | 02-OCT-13:00 | 15.28 | 10.42 |
November | 0.101691E+11 | 5449.73 | 09-NOV-16:20 | 0.53 | -4.0 | 94300508.08 | 126.83 | 21-NOV-14:39 | 11.87 | 10.94 |
December | 0.137721E+11 | 6770.03 | 20-DEC-16:00 | -20.2 | -20.8 | 91880861.84 | 126.82 | 01-DEC-10:09 | -20.2 | -20.8 |
Annual Sum or Average | 0.112017E+12 | 0.113770E+10 | ||||||||
Minimum of Months | 0.461431E+09 | 1610.46 | -20.2 | -20.8 | 86396470.61 | 126.82 | -20.2 | -20.8 | ||
Maximum of Months | 0.186638E+11 | 8068.09 | 18.53 | 15.17 | 0.103240E+09 | 126.86 | 20.60 | 18.71 |
Report: ZoneCoolingSummaryMonthly
For: DATACENTER_TOP_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.339680E+09 | 1273.22 | 20-JAN-16:30 | -6.4 | -7.8 | 84291029.34 | 126.82 | 19-JAN-14:00 | -6.4 | -7.8 |
February | 0.269244E+10 | 3699.80 | 08-FEB-17:00 | 3.30 | -1.3 | 86385313.73 | 126.82 | 23-FEB-14:09 | -5.8 | -7.7 |
March | 0.916986E+10 | 5855.34 | 31-MAR-23:20 | 3.93 | 0.64 | 0.103236E+09 | 126.82 | 30-MAR-13:09 | 3.93 | 0.64 |
April | 0.152661E+11 | 8037.47 | 21-APR-18:10 | 10.82 | 2.42 | 91605671.41 | 126.82 | 27-APR-13:09 | 1.28 | -2.0 |
May | 0.339182E+10 | 2557.92 | 25-MAY-18:40 | 27.93 | 18.77 | 99231299.96 | 126.85 | 26-MAY-09:00 | 22.60 | 18.32 |
June | 0.841706E+10 | 5204.46 | 30-JUN-23:55 | 16.10 | 13.43 | 98967015.47 | 126.86 | 30-JUN-09:00 | 16.10 | 13.43 |
July | 0.139604E+11 | 6838.69 | 31-JUL-23:55 | 17.00 | 15.17 | 91889173.69 | 126.85 | 05-JUL-09:00 | 17.00 | 15.17 |
August | 0.184674E+11 | 7996.20 | 02-AUG-18:40 | 18.53 | 13.51 | 0.103241E+09 | 126.83 | 31-AUG-09:50 | 18.80 | 17.74 |
September | 0.264753E+10 | 2631.27 | 05-SEP-17:50 | 15.78 | 9.39 | 91607021.10 | 126.85 | 01-SEP-13:00 | 15.78 | 9.39 |
October | 0.547848E+10 | 3979.47 | 19-OCT-16:50 | 19.78 | 12.93 | 95230302.26 | 126.83 | 02-OCT-13:00 | 19.78 | 12.93 |
November | 0.814289E+10 | 5241.84 | 09-NOV-16:20 | 0.53 | -4.0 | 94300514.40 | 126.83 | 21-NOV-14:39 | 11.87 | 10.94 |
December | 0.119295E+11 | 6459.07 | 20-DEC-16:00 | -20.2 | -20.8 | 91880863.70 | 126.82 | 01-DEC-10:09 | -20.2 | -20.8 |
Annual Sum or Average | 0.999032E+11 | 0.113187E+10 | ||||||||
Minimum of Months | 0.339680E+09 | 1273.22 | -20.2 | -20.8 | 84291029.34 | 126.82 | -20.2 | -20.8 | ||
Maximum of Months | 0.184674E+11 | 8037.47 | 27.93 | 18.77 | 0.103241E+09 | 126.86 | 22.60 | 18.32 |
Report: ZoneCoolingSummaryMonthly
For: DATACENTER_BASEMENT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.232211E+12 | 90828.34 | 20-JAN-17:00 | -7.2 | -8.4 | 0.206152E+10 | 2747.23 | 19-JAN-14:00 | -7.2 | -8.4 |
February | 0.432340E+12 | 182896.74 | 22-FEB-17:00 | -1.1 | -3.9 | 0.187087E+10 | 2749.27 | 03-FEB-10:09 | -1.1 | -3.9 |
March | 0.725522E+12 | 358325.42 | 31-MAR-24:00 | 3.60 | 0.45 | 0.223651E+10 | 2749.90 | 16-MAR-09:09 | 3.60 | 0.45 |
April | 0.941008E+12 | 367337.55 | 19-APR-16:00 | 7.20 | 1.06 | 0.198477E+10 | 2749.05 | 21-APR-13:09 | 10.68 | 2.54 |
May | 0.240546E+12 | 175261.00 | 31-MAY-24:00 | 11.20 | 9.10 | 0.214827E+10 | 2747.09 | 05-MAY-09:09 | 11.20 | 9.10 |
June | 0.469974E+12 | 268028.79 | 30-JUN-23:55 | 16.10 | 13.43 | 0.214240E+10 | 2746.25 | 30-JUN-13:00 | 16.10 | 13.43 |
July | 0.732719E+12 | 360144.57 | 31-JUL-24:00 | 17.00 | 15.17 | 0.198910E+10 | 2745.83 | 05-JUL-13:30 | 17.00 | 15.17 |
August | 0.978605E+12 | 370439.48 | 09-AUG-21:02 | 21.02 | 18.85 | 0.227650E+10 | 3273.42 | 08-AUG-13:00 | 21.02 | 18.85 |
September | 0.235825E+12 | 175856.06 | 30-SEP-24:00 | 7.80 | 6.76 | 0.198310E+10 | 2746.34 | 19-SEP-13:00 | 7.80 | 6.76 |
October | 0.486358E+12 | 267242.69 | 31-OCT-24:00 | 3.30 | -0.4 | 0.206175E+10 | 2747.05 | 12-OCT-13:09 | 3.30 | -0.4 |
November | 0.705945E+12 | 276268.74 | 17-NOV-17:00 | 6.70 | 1.30 | 0.204270E+10 | 2749.18 | 09-NOV-14:00 | 6.70 | 1.30 |
December | 0.971277E+12 | 366940.80 | 06-DEC-16:45 | -7.0 | -7.1 | 0.199147E+10 | 2750.17 | 18-DEC-10:09 | -21.8 | -22.5 |
Annual Sum or Average | 0.715233E+13 | 0.247890E+11 | ||||||||
Minimum of Months | 0.232211E+12 | 90828.34 | -7.2 | -8.4 | 0.187087E+10 | 2745.83 | -21.8 | -22.5 | ||
Maximum of Months | 0.978605E+12 | 370439.48 | 21.02 | 18.85 | 0.227650E+10 | 3273.42 | 21.02 | 18.85 |
Report: ZoneHeatingSummaryMonthly
For: BASEMENT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.118828E+09 | 11639.93 | 21-JAN-05:03 | -22.2 |
February | 67344041.45 | 11676.33 | 06-FEB-05:03 | -20.1 |
March | 0.117085E+09 | 12009.18 | 21-MAR-04:04 | 0.00 |
April | 0.142840E+09 | 12122.80 | 17-APR-03:04 | -0.7 |
May | 0.291314E+09 | 12176.65 | 20-MAY-04:05 | 6.25 |
June | 0.277447E+09 | 15377.35 | 24-JUN-16:02 | 28.98 |
July | 0.376073E+09 | 17561.74 | 29-JUL-16:01 | 30.50 |
August | 0.398722E+09 | 13892.45 | 28-AUG-01:53 | 13.90 |
September | 0.509384E+09 | 14271.92 | 04-SEP-16:52 | 16.10 |
October | 0.428612E+09 | 12216.66 | 11-OCT-03:15 | 1.67 |
November | 0.220406E+09 | 11827.03 | 14-NOV-04:03 | 2.88 |
December | 76711817.26 | 11649.72 | 12-DEC-05:03 | -12.1 |
Annual Sum or Average | 0.302477E+10 | |||
Minimum of Months | 67344041.45 | 11639.93 | -22.2 | |
Maximum of Months | 0.509384E+09 | 17561.74 | 30.50 |
Report: ZoneHeatingSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 4324189.12 | 16037.65 | 02-JAN-06:01 | -17.8 |
February | 0.00 | 0.00 | 01-FEB-00:03 | -23.1 |
March | 0.00 | 0.00 | 01-MAR-00:10 | -1.3 |
April | 0.00 | 0.00 | 01-APR-00:10 | 3.52 |
May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 19.75 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 |
December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 |
Annual Sum or Average | 4324189.12 | |||
Minimum of Months | 0.00 | 0.00 | -23.1 | |
Maximum of Months | 4324189.12 | 16037.65 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.158714E+10 | 62514.04 | 02-JAN-04:01 | -18.8 |
February | 0.233786E+09 | 52185.09 | 27-FEB-05:01 | -17.4 |
March | 18096903.49 | 48568.53 | 06-MAR-06:03 | -19.0 |
April | 1086914.18 | 7246.09 | 05-APR-15:40 | -0.2 |
May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 19.75 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 |
November | 0.111968E+09 | 52748.91 | 27-NOV-05:11 | -7.2 |
December | 0.725156E+09 | 56251.22 | 26-DEC-05:11 | -26.1 |
Annual Sum or Average | 0.267723E+10 | |||
Minimum of Months | 0.00 | 0.00 | -26.1 | |
Maximum of Months | 0.158714E+10 | 62514.04 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.109589E+11 | 81973.98 | 09-JAN-04:11 | -32.6 |
February | 0.552239E+10 | 79538.14 | 13-FEB-04:01 | -22.9 |
March | 0.255415E+10 | 78806.50 | 06-MAR-04:01 | -17.4 |
April | 0.628721E+09 | 72604.26 | 03-APR-04:01 | -5.4 |
May | 7499552.23 | 49997.01 | 01-MAY-05:03 | -3.4 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 19.75 |
October | 0.649080E+09 | 74038.16 | 30-OCT-03:11 | -9.6 |
November | 0.337313E+10 | 78219.41 | 27-NOV-04:01 | -7.2 |
December | 0.856706E+10 | 81238.13 | 11-DEC-04:11 | -24.7 |
Annual Sum or Average | 0.322610E+11 | |||
Minimum of Months | 0.00 | 0.00 | -32.6 | |
Maximum of Months | 0.109589E+11 | 81973.98 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.292947E+10 | 13733.58 | 01-JAN-09:18 | -25.9 |
February | 0.706993E+09 | 12097.58 | 13-FEB-05:01 | -23.4 |
March | 0.113420E+09 | 11499.82 | 06-MAR-05:01 | -18.4 |
April | 0.00 | 0.00 | 01-APR-00:10 | 3.52 |
May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 19.75 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 |
November | 43869664.25 | 11016.86 | 25-NOV-06:01 | -19.4 |
December | 0.827646E+09 | 12227.44 | 26-DEC-05:01 | -25.9 |
Annual Sum or Average | 0.462140E+10 | |||
Minimum of Months | 0.00 | 0.00 | -25.9 | |
Maximum of Months | 0.292947E+10 | 13733.58 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.180249E+10 | 16081.17 | 02-JAN-04:01 | -18.8 |
February | 0.506069E+09 | 14019.71 | 13-FEB-05:01 | -23.4 |
March | 0.104284E+09 | 13406.81 | 06-MAR-05:01 | -18.4 |
April | 822758.41 | 4259.27 | 04-APR-05:01 | -9.0 |
May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 19.75 |
October | 124691.38 | 831.28 | 18-OCT-05:03 | 2.12 |
November | 73410844.70 | 12792.32 | 25-NOV-05:01 | -19.0 |
December | 0.816704E+09 | 14281.54 | 20-DEC-05:01 | -28.7 |
Annual Sum or Average | 0.330390E+10 | |||
Minimum of Months | 0.00 | 0.00 | -28.7 | |
Maximum of Months | 0.180249E+10 | 16081.17 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.219314E+10 | 22386.95 | 09-JAN-04:01 | -32.4 |
February | 0.743318E+09 | 20834.53 | 13-FEB-04:01 | -22.9 |
March | 0.201200E+09 | 19942.75 | 06-MAR-05:01 | -18.4 |
April | 4928975.72 | 16532.02 | 10-APR-05:01 | -2.7 |
May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 19.75 |
October | 9713631.79 | 12638.36 | 30-OCT-05:03 | -9.9 |
November | 0.172397E+09 | 19200.06 | 25-NOV-05:01 | -19.0 |
December | 0.106243E+10 | 21116.22 | 26-DEC-04:01 | -25.0 |
Annual Sum or Average | 0.438714E+10 | |||
Minimum of Months | 0.00 | 0.00 | -32.4 | |
Maximum of Months | 0.219314E+10 | 22386.95 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.688193E+09 | 13672.11 | 09-JAN-04:01 | -32.4 |
February | 63760078.81 | 11716.51 | 13-FEB-05:01 | -23.4 |
March | 2442618.26 | 10559.10 | 15-MAR-05:01 | -22.2 |
April | 0.00 | 0.00 | 01-APR-00:10 | 3.52 |
May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 19.75 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 |
November | 1660375.54 | 10667.92 | 25-NOV-06:01 | -19.4 |
December | 20656607.96 | 11512.66 | 26-DEC-05:01 | -25.9 |
Annual Sum or Average | 0.776713E+09 | |||
Minimum of Months | 0.00 | 0.00 | -32.4 | |
Maximum of Months | 0.688193E+09 | 13672.11 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.111333E+11 | 13599.10 | 01-JAN-08:61 | -26.7 |
February | 0.595077E+10 | 13396.68 | 12-FEB-23:11 | -17.6 |
March | 0.271845E+10 | 13026.21 | 06-MAR-04:11 | -17.6 |
April | 0.346282E+09 | 11585.45 | 03-APR-04:01 | -5.4 |
May | 501936.20 | 3246.69 | 01-MAY-05:03 | -3.4 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 19.75 |
October | 0.186107E+09 | 11256.72 | 30-OCT-04:01 | -10.0 |
November | 0.226394E+10 | 13088.84 | 26-NOV-23:52 | -6.7 |
December | 0.975579E+10 | 13798.52 | 24-DEC-22:32 | -29.1 |
Annual Sum or Average | 0.323551E+11 | |||
Minimum of Months | 0.00 | 0.00 | -29.1 | |
Maximum of Months | 0.111333E+11 | 13798.52 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.667339E+10 | 19868.88 | 01-JAN-08:61 | -26.7 |
February | 0.305677E+10 | 19729.16 | 12-FEB-23:11 | -17.6 |
March | 0.133504E+10 | 19142.91 | 06-MAR-04:11 | -17.6 |
April | 0.163924E+09 | 16953.23 | 03-APR-04:01 | -5.4 |
May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 46975.70 | 313.17 | 21-SEP-05:08 | 5.50 |
October | 0.126501E+09 | 16600.09 | 30-OCT-04:01 | -10.0 |
November | 0.145010E+10 | 18682.57 | 25-NOV-04:01 | -18.0 |
December | 0.604948E+10 | 19987.35 | 24-DEC-07:12 | -31.1 |
Annual Sum or Average | 0.188552E+11 | |||
Minimum of Months | 0.00 | 0.00 | -31.1 | |
Maximum of Months | 0.667339E+10 | 19987.35 | 17.07 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.652365E+10 | 23799.75 | 01-JAN-08:61 | -26.7 |
February | 0.289080E+10 | 23507.24 | 13-FEB-03:51 | -22.8 |
March | 0.128101E+10 | 22749.10 | 06-MAR-04:11 | -17.6 |
April | 0.204177E+09 | 19938.34 | 04-APR-04:01 | -7.5 |
May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 19.75 |
October | 0.116135E+09 | 19717.56 | 30-OCT-04:01 | -10.0 |
November | 0.148397E+10 | 22347.69 | 25-NOV-04:01 | -18.0 |
December | 0.607108E+10 | 23988.29 | 24-DEC-07:12 | -31.1 |
Annual Sum or Average | 0.185708E+11 | |||
Minimum of Months | 0.00 | 0.00 | -31.1 | |
Maximum of Months | 0.652365E+10 | 23988.29 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.578693E+10 | 20694.65 | 01-JAN-08:61 | -26.7 |
February | 0.252529E+10 | 20302.60 | 13-FEB-03:51 | -22.8 |
March | 0.946862E+09 | 19725.64 | 06-MAR-04:11 | -17.6 |
April | 0.109422E+09 | 16991.87 | 03-APR-04:01 | -5.4 |
May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 9275.70 | 61.84 | 29-SEP-05:08 | 7.20 |
October | 68042579.62 | 16451.32 | 30-OCT-04:01 | -10.0 |
November | 0.973104E+09 | 19134.60 | 25-NOV-04:01 | -18.0 |
December | 0.470238E+10 | 20574.86 | 24-DEC-07:12 | -31.1 |
Annual Sum or Average | 0.151120E+11 | |||
Minimum of Months | 0.00 | 0.00 | -31.1 | |
Maximum of Months | 0.578693E+10 | 20694.65 | 17.07 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.189445E+11 | 19147.13 | 09-JAN-04:11 | -32.6 |
February | 0.125640E+11 | 18390.39 | 19-FEB-03:02 | -21.7 |
March | 0.752115E+10 | 17969.69 | 05-MAR-21:42 | -12.8 |
April | 0.193941E+10 | 16948.49 | 02-APR-07:43 | -5.7 |
May | 76778034.85 | 14845.64 | 01-MAY-04:01 | -2.9 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 51431684.75 | 13395.07 | 20-SEP-05:02 | 5.60 |
October | 0.155798E+10 | 16873.97 | 30-OCT-03:11 | -9.6 |
November | 0.703837E+10 | 17900.54 | 23-NOV-21:42 | -10.5 |
December | 0.177403E+11 | 18811.03 | 11-DEC-04:11 | -24.7 |
Annual Sum or Average | 0.674339E+11 | |||
Minimum of Months | 0.00 | 0.00 | -32.6 | |
Maximum of Months | 0.189445E+11 | 19147.13 | 17.07 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.115940E+11 | 21541.98 | 09-JAN-04:11 | -32.6 |
February | 0.694309E+10 | 20621.15 | 13-FEB-04:01 | -22.9 |
March | 0.371573E+10 | 19836.86 | 05-MAR-21:42 | -12.8 |
April | 0.896402E+09 | 18748.46 | 10-APR-03:01 | -1.9 |
May | 27373655.06 | 16041.13 | 01-MAY-04:01 | -2.9 |
June | 3809.37 | 25.40 | 10-JUN-05:05 | 14.60 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 30020.97 | 119.84 | 19-AUG-05:05 | 4.60 |
September | 39378632.73 | 13404.45 | 20-SEP-05:02 | 5.60 |
October | 0.904536E+09 | 18992.93 | 30-OCT-03:11 | -9.6 |
November | 0.424592E+10 | 19875.69 | 26-NOV-23:52 | -6.7 |
December | 0.111229E+11 | 21131.50 | 11-DEC-04:11 | -24.7 |
Annual Sum or Average | 0.394894E+11 | |||
Minimum of Months | 0.00 | 0.00 | -32.6 | |
Maximum of Months | 0.115940E+11 | 21541.98 | 15.83 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.128610E+11 | 27336.55 | 09-JAN-04:11 | -32.6 |
February | 0.742118E+10 | 26115.55 | 13-FEB-04:01 | -22.9 |
March | 0.434710E+10 | 25329.23 | 05-MAR-07:02 | -28.5 |
April | 0.125387E+10 | 23888.58 | 10-APR-03:01 | -1.9 |
May | 59397289.48 | 20233.68 | 01-MAY-04:01 | -2.9 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 81879.31 | 545.86 | 19-AUG-05:05 | 4.60 |
September | 40268394.15 | 16961.32 | 20-SEP-05:02 | 5.60 |
October | 0.107455E+10 | 24141.03 | 30-OCT-03:11 | -9.6 |
November | 0.496381E+10 | 25360.73 | 23-NOV-21:42 | -10.5 |
December | 0.128698E+11 | 26492.93 | 11-DEC-04:11 | -24.7 |
Annual Sum or Average | 0.448911E+11 | |||
Minimum of Months | 0.00 | 0.00 | -32.6 | |
Maximum of Months | 0.128698E+11 | 27336.55 | 15.83 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.106283E+11 | 23625.88 | 09-JAN-04:11 | -32.6 |
February | 0.579934E+10 | 22479.83 | 13-FEB-04:01 | -22.9 |
March | 0.294747E+10 | 21481.43 | 05-MAR-07:02 | -28.5 |
April | 0.636717E+09 | 20177.46 | 10-APR-03:01 | -1.9 |
May | 21930788.34 | 9999.92 | 09-MAY-05:02 | 4.83 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 14072202.37 | 10819.95 | 20-SEP-05:02 | 5.60 |
October | 0.582981E+09 | 20593.24 | 30-OCT-03:11 | -9.6 |
November | 0.308878E+10 | 21394.25 | 23-NOV-21:42 | -10.5 |
December | 0.914710E+10 | 22818.47 | 11-DEC-04:11 | -24.7 |
Annual Sum or Average | 0.328667E+11 | |||
Minimum of Months | 0.00 | 0.00 | -32.6 | |
Maximum of Months | 0.106283E+11 | 23625.88 | 17.07 |
Report: ZoneHeatingSummaryMonthly
For: GROUNDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.401036E+10 | 12827.00 | 19-JAN-06:01 | -3.3 |
February | 0.158324E+10 | 14433.17 | 21-FEB-06:03 | 2.80 |
March | 0.791764E+09 | 14256.29 | 09-MAR-06:01 | -1.3 |
April | 0.159751E+09 | 13477.89 | 18-APR-03:02 | 11.70 |
May | 93912711.51 | 10516.63 | 01-MAY-03:02 | -2.1 |
June | 90538560.73 | 10860.82 | 12-JUN-03:02 | 12.20 |
July | 0.128288E+09 | 8387.06 | 23-JUL-15:32 | 30.00 |
August | 0.140804E+09 | 11706.35 | 18-AUG-03:02 | 11.78 |
September | 87899525.70 | 10284.82 | 11-SEP-03:02 | 11.78 |
October | 99506761.02 | 12364.12 | 10-OCT-03:01 | 1.28 |
November | 0.349055E+09 | 14875.90 | 30-NOV-06:01 | -2.1 |
December | 0.205629E+10 | 16336.18 | 28-DEC-06:01 | -2.3 |
Annual Sum or Average | 0.959141E+10 | |||
Minimum of Months | 87899525.70 | 8387.06 | -3.3 | |
Maximum of Months | 0.401036E+10 | 16336.18 | 30.00 |
Report: ZoneHeatingSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.900446E+10 | 22429.56 | 02-JAN-06:23 | -17.8 |
February | 0.481244E+10 | 10282.66 | 27-FEB-13:40 | -9.1 |
March | 0.280990E+10 | 12823.33 | 10-MAR-16:00 | 0.00 |
April | 0.704179E+09 | 11446.68 | 23-APR-16:01 | 26.60 |
May | 92212838.16 | 8034.08 | 30-MAY-03:02 | 10.60 |
June | 56521522.70 | 8085.39 | 12-JUN-04:02 | 12.12 |
July | 64093392.04 | 7704.06 | 23-JUL-15:32 | 30.00 |
August | 62809433.26 | 7821.64 | 13-AUG-15:32 | 22.40 |
September | 64627334.29 | 8447.44 | 03-SEP-15:52 | 21.70 |
October | 0.349472E+09 | 9314.21 | 09-OCT-13:42 | 6.02 |
November | 0.243012E+10 | 9422.08 | 27-NOV-06:04 | -7.1 |
December | 0.681329E+10 | 17332.78 | 26-DEC-06:15 | -26.6 |
Annual Sum or Average | 0.272641E+11 | |||
Minimum of Months | 56521522.70 | 7704.06 | -26.6 | |
Maximum of Months | 0.900446E+10 | 22429.56 | 30.00 |
Report: ZoneHeatingSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.261417E+11 | 35723.88 | 09-JAN-05:09 | -33.0 |
February | 0.175340E+11 | 33444.62 | 14-FEB-06:12 | -32.2 |
March | 0.116860E+11 | 30786.28 | 06-MAR-05:07 | -18.4 |
April | 0.379113E+10 | 23362.80 | 03-APR-04:12 | -5.2 |
May | 0.525202E+09 | 18417.66 | 04-MAY-05:03 | 4.40 |
June | 0.118301E+09 | 16418.30 | 17-JUN-05:03 | 5.55 |
July | 0.104861E+09 | 16029.00 | 18-JUL-05:03 | 8.27 |
August | 0.121581E+09 | 14586.60 | 25-AUG-04:02 | 8.72 |
September | 0.624483E+09 | 18160.73 | 07-SEP-05:02 | 6.20 |
October | 0.375628E+10 | 24022.83 | 30-OCT-04:13 | -10.0 |
November | 0.114422E+11 | 27788.91 | 24-NOV-05:12 | -10.6 |
December | 0.241333E+11 | 33536.93 | 20-DEC-06:12 | -29.0 |
Annual Sum or Average | 0.999790E+11 | |||
Minimum of Months | 0.104861E+09 | 14586.60 | -33.0 | |
Maximum of Months | 0.261417E+11 | 35723.88 | 8.72 |
Report: ZoneHeatingSummaryMonthly
For: DATACENTER_BOT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.101772E+09 | 600.81 | 01-JAN-19:50 | -21.6 |
February | 0.00 | 0.00 | 01-FEB-00:03 | -23.1 |
March | 0.00 | 0.00 | 01-MAR-00:10 | -1.3 |
April | 0.00 | 0.00 | 01-APR-00:10 | 3.52 |
May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 19.75 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 |
December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 |
Annual Sum or Average | 0.101772E+09 | |||
Minimum of Months | 0.00 | 0.00 | -23.1 | |
Maximum of Months | 0.101772E+09 | 600.81 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: DATACENTER_MID_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.731186E+09 | 604.07 | 01-JAN-17:10 | -19.1 |
February | 0.00 | 0.00 | 01-FEB-00:03 | -23.1 |
March | 0.00 | 0.00 | 01-MAR-00:10 | -1.3 |
April | 0.00 | 0.00 | 01-APR-00:10 | 3.52 |
May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 19.75 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 |
December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 |
Annual Sum or Average | 0.731186E+09 | |||
Minimum of Months | 0.00 | 0.00 | -23.1 | |
Maximum of Months | 0.731186E+09 | 604.07 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: DATACENTER_TOP_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.799765E+09 | 629.34 | 09-JAN-23:35 | -19.2 |
February | 0.170722E+09 | 584.26 | 12-FEB-23:37 | -17.9 |
March | 0.00 | 0.00 | 01-MAR-00:10 | -1.3 |
April | 0.00 | 0.00 | 01-APR-00:10 | 3.52 |
May | 5925377.46 | 437.66 | 01-MAY-05:20 | -3.5 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 19.75 |
October | 3872947.90 | 401.59 | 29-OCT-22:00 | -6.7 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 |
December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 |
Annual Sum or Average | 0.980285E+09 | |||
Minimum of Months | 0.00 | 0.00 | -19.2 | |
Maximum of Months | 0.799765E+09 | 629.34 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: DATACENTER_BASEMENT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:01 | -21.9 |
February | 0.00 | 0.00 | 01-FEB-00:03 | -23.1 |
March | 0.00 | 0.00 | 01-MAR-00:10 | -1.3 |
April | 0.00 | 0.00 | 01-APR-00:10 | 3.52 |
May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 17.07 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 19.75 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 |
December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | -23.1 | |
Maximum of Months | 0.00 | 0.00 | 19.75 |
Report: ZoneElectricSummaryMonthly
For: BASEMENT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.200626E+11 | 20994.62 | 02-JAN-08:09 | 0.360447E+11 | 13457.54 | 01-JAN-00:10 |
February | 0.181982E+11 | 20994.62 | 01-FEB-08:09 | 0.325565E+11 | 13457.54 | 01-FEB-00:10 |
March | 0.216246E+11 | 20994.62 | 01-MAR-08:09 | 0.360447E+11 | 13457.54 | 01-MAR-00:10 |
April | 0.193152E+11 | 20994.62 | 03-APR-07:10 | 0.348820E+11 | 13457.54 | 01-APR-00:10 |
May | 0.208436E+11 | 20994.62 | 01-MAY-07:10 | 0.360447E+11 | 13457.54 | 01-MAY-00:10 |
June | 0.207428E+11 | 20994.62 | 01-JUN-07:10 | 0.348820E+11 | 13457.54 | 01-JUN-00:10 |
July | 0.194159E+11 | 20994.62 | 03-JUL-07:10 | 0.360447E+11 | 13457.54 | 01-JUL-00:10 |
August | 0.216246E+11 | 20994.62 | 01-AUG-07:10 | 0.360447E+11 | 13457.54 | 01-AUG-00:10 |
September | 0.193152E+11 | 20994.62 | 01-SEP-07:10 | 0.348820E+11 | 13457.54 | 01-SEP-00:10 |
October | 0.200626E+11 | 20994.62 | 02-OCT-07:10 | 0.360447E+11 | 13457.54 | 01-OCT-00:10 |
November | 0.198274E+11 | 20994.62 | 01-NOV-07:10 | 0.348820E+11 | 13457.54 | 01-NOV-00:10 |
December | 0.194159E+11 | 20994.62 | 01-DEC-08:09 | 0.360447E+11 | 13457.54 | 01-DEC-00:10 |
Annual Sum or Average | 0.240449E+12 | 0.424397E+12 | ||||
Minimum of Months | 0.181982E+11 | 20994.62 | 0.325565E+11 | 13457.54 | ||
Maximum of Months | 0.216246E+11 | 20994.62 | 0.360447E+11 | 13457.54 |
Report: ZoneElectricSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.180176E+11 | 18854.65 | 02-JAN-08:09 | 0.270551E+11 | 18128.59 | 02-JAN-08:09 |
February | 0.163433E+11 | 18854.65 | 01-FEB-08:09 | 0.244881E+11 | 18128.59 | 01-FEB-08:09 |
March | 0.194204E+11 | 18854.65 | 01-MAR-08:09 | 0.280558E+11 | 18128.59 | 01-MAR-08:09 |
April | 0.173464E+11 | 18854.65 | 03-APR-07:10 | 0.261305E+11 | 18128.59 | 03-APR-07:10 |
May | 0.187190E+11 | 18854.65 | 01-MAY-07:10 | 0.275555E+11 | 18128.59 | 01-MAY-07:10 |
June | 0.186285E+11 | 18854.65 | 01-JUN-07:10 | 0.270261E+11 | 18128.59 | 01-JUN-07:10 |
July | 0.174369E+11 | 18854.65 | 03-JUL-07:10 | 0.266527E+11 | 18128.59 | 03-JUL-07:10 |
August | 0.194204E+11 | 18854.65 | 01-AUG-07:10 | 0.280558E+11 | 18128.59 | 01-AUG-07:10 |
September | 0.173464E+11 | 18854.65 | 01-SEP-07:10 | 0.261160E+11 | 18128.59 | 01-SEP-07:10 |
October | 0.180176E+11 | 18854.65 | 02-OCT-07:10 | 0.270624E+11 | 18128.59 | 02-OCT-07:10 |
November | 0.178064E+11 | 18854.65 | 01-NOV-07:10 | 0.264424E+11 | 18128.59 | 01-NOV-07:10 |
December | 0.174369E+11 | 18854.65 | 01-DEC-08:09 | 0.266454E+11 | 18128.59 | 01-DEC-08:09 |
Annual Sum or Average | 0.215940E+12 | 0.321286E+12 | ||||
Minimum of Months | 0.163433E+11 | 18854.65 | 0.244881E+11 | 18128.59 | ||
Maximum of Months | 0.194204E+11 | 18854.65 | 0.280558E+11 | 18128.59 |
Report: ZoneElectricSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.180176E+11 | 18854.65 | 02-JAN-08:09 | 0.270550E+11 | 18128.52 | 02-JAN-08:09 |
February | 0.163433E+11 | 18854.65 | 01-FEB-08:09 | 0.244880E+11 | 18128.52 | 01-FEB-08:09 |
March | 0.194204E+11 | 18854.65 | 01-MAR-08:09 | 0.280557E+11 | 18128.52 | 01-MAR-08:09 |
April | 0.173464E+11 | 18854.65 | 03-APR-07:10 | 0.261304E+11 | 18128.52 | 03-APR-07:10 |
May | 0.187190E+11 | 18854.65 | 01-MAY-07:10 | 0.275554E+11 | 18128.52 | 01-MAY-07:10 |
June | 0.186285E+11 | 18854.65 | 01-JUN-07:10 | 0.270260E+11 | 18128.52 | 01-JUN-07:10 |
July | 0.174369E+11 | 18854.65 | 03-JUL-07:10 | 0.266526E+11 | 18128.52 | 03-JUL-07:10 |
August | 0.194204E+11 | 18854.65 | 01-AUG-07:10 | 0.280557E+11 | 18128.52 | 01-AUG-07:10 |
September | 0.173464E+11 | 18854.65 | 01-SEP-07:10 | 0.261159E+11 | 18128.52 | 01-SEP-07:10 |
October | 0.180176E+11 | 18854.65 | 02-OCT-07:10 | 0.270623E+11 | 18128.52 | 02-OCT-07:10 |
November | 0.178064E+11 | 18854.65 | 01-NOV-07:10 | 0.264423E+11 | 18128.52 | 01-NOV-07:10 |
December | 0.174369E+11 | 18854.65 | 01-DEC-08:09 | 0.266453E+11 | 18128.52 | 01-DEC-08:09 |
Annual Sum or Average | 0.215940E+12 | 0.321285E+12 | ||||
Minimum of Months | 0.163433E+11 | 18854.65 | 0.244880E+11 | 18128.52 | ||
Maximum of Months | 0.194204E+11 | 18854.65 | 0.280557E+11 | 18128.52 |
Report: ZoneElectricSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.180176E+11 | 18854.65 | 02-JAN-08:09 | 0.270550E+11 | 18128.52 | 02-JAN-08:09 |
February | 0.163433E+11 | 18854.65 | 01-FEB-08:09 | 0.244880E+11 | 18128.52 | 01-FEB-08:09 |
March | 0.194204E+11 | 18854.65 | 01-MAR-08:09 | 0.280557E+11 | 18128.52 | 01-MAR-08:09 |
April | 0.173464E+11 | 18854.65 | 03-APR-07:10 | 0.261304E+11 | 18128.52 | 03-APR-07:10 |
May | 0.187190E+11 | 18854.65 | 01-MAY-07:10 | 0.275554E+11 | 18128.52 | 01-MAY-07:10 |
June | 0.186285E+11 | 18854.65 | 01-JUN-07:10 | 0.270260E+11 | 18128.52 | 01-JUN-07:10 |
July | 0.174369E+11 | 18854.65 | 03-JUL-07:10 | 0.266526E+11 | 18128.52 | 03-JUL-07:10 |
August | 0.194204E+11 | 18854.65 | 01-AUG-07:10 | 0.280557E+11 | 18128.52 | 01-AUG-07:10 |
September | 0.173464E+11 | 18854.65 | 01-SEP-07:10 | 0.261159E+11 | 18128.52 | 01-SEP-07:10 |
October | 0.180176E+11 | 18854.65 | 02-OCT-07:10 | 0.270623E+11 | 18128.52 | 02-OCT-07:10 |
November | 0.178064E+11 | 18854.65 | 01-NOV-07:10 | 0.264423E+11 | 18128.52 | 01-NOV-07:10 |
December | 0.174369E+11 | 18854.65 | 01-DEC-08:09 | 0.266453E+11 | 18128.52 | 01-DEC-08:09 |
Annual Sum or Average | 0.215940E+12 | 0.321285E+12 | ||||
Minimum of Months | 0.163433E+11 | 18854.65 | 0.244880E+11 | 18128.52 | ||
Maximum of Months | 0.194204E+11 | 18854.65 | 0.280557E+11 | 18128.52 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.172293E+10 | 2367.39 | 02-JAN-08:09 | 0.339718E+10 | 2276.32 | 02-JAN-08:09 |
February | 0.145986E+10 | 2108.91 | 01-FEB-16:00 | 0.307485E+10 | 2276.32 | 01-FEB-08:09 |
March | 0.166660E+10 | 1954.24 | 03-MAR-16:00 | 0.352283E+10 | 2276.32 | 01-MAR-08:09 |
April | 0.144861E+10 | 1454.29 | 03-APR-07:10 | 0.328108E+10 | 2276.32 | 03-APR-07:10 |
May | 0.152729E+10 | 1454.29 | 01-MAY-07:10 | 0.346000E+10 | 2276.32 | 01-MAY-07:10 |
June | 0.150838E+10 | 1454.29 | 01-JUN-07:10 | 0.339353E+10 | 2276.32 | 01-JUN-07:10 |
July | 0.142029E+10 | 1454.29 | 03-JUL-07:10 | 0.334664E+10 | 2276.32 | 03-JUL-07:10 |
August | 0.160642E+10 | 1769.31 | 31-AUG-07:10 | 0.352283E+10 | 2276.32 | 01-AUG-07:10 |
September | 0.146676E+10 | 1804.02 | 19-SEP-07:10 | 0.327926E+10 | 2276.32 | 01-SEP-07:10 |
October | 0.158733E+10 | 2342.45 | 31-OCT-07:10 | 0.339809E+10 | 2276.32 | 02-OCT-07:10 |
November | 0.167342E+10 | 2367.39 | 06-NOV-16:49 | 0.332024E+10 | 2276.32 | 01-NOV-07:10 |
December | 0.169367E+10 | 2367.39 | 01-DEC-16:19 | 0.334573E+10 | 2276.32 | 01-DEC-08:09 |
Annual Sum or Average | 0.187816E+11 | 0.403423E+11 | ||||
Minimum of Months | 0.142029E+10 | 1454.29 | 0.307485E+10 | 2276.32 | ||
Maximum of Months | 0.172293E+10 | 2367.39 | 0.352283E+10 | 2276.32 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.109597E+10 | 1525.64 | 02-JAN-08:09 | 0.218927E+10 | 1466.95 | 02-JAN-08:09 |
February | 0.937136E+09 | 1382.36 | 02-FEB-16:00 | 0.198155E+10 | 1466.95 | 01-FEB-08:09 |
March | 0.107173E+10 | 1277.67 | 03-MAR-16:00 | 0.227025E+10 | 1466.95 | 01-MAR-08:09 |
April | 0.934499E+09 | 937.20 | 03-APR-07:10 | 0.211446E+10 | 1466.95 | 03-APR-07:10 |
May | 0.987735E+09 | 937.20 | 01-MAY-07:10 | 0.222976E+10 | 1466.95 | 01-MAY-07:10 |
June | 0.976118E+09 | 937.20 | 01-JUN-07:10 | 0.218692E+10 | 1466.95 | 01-JUN-07:10 |
July | 0.918774E+09 | 937.20 | 03-JUL-07:10 | 0.215670E+10 | 1466.95 | 03-JUL-07:10 |
August | 0.103720E+10 | 1087.18 | 31-AUG-07:10 | 0.227025E+10 | 1466.95 | 01-AUG-07:10 |
September | 0.945381E+09 | 1085.97 | 19-SEP-07:10 | 0.211328E+10 | 1466.95 | 01-SEP-07:10 |
October | 0.101720E+10 | 1504.78 | 31-OCT-07:10 | 0.218986E+10 | 1466.95 | 02-OCT-07:10 |
November | 0.107026E+10 | 1525.64 | 06-NOV-16:49 | 0.213969E+10 | 1466.95 | 01-NOV-07:10 |
December | 0.107948E+10 | 1525.64 | 01-DEC-16:19 | 0.215612E+10 | 1466.95 | 01-DEC-08:09 |
Annual Sum or Average | 0.120715E+11 | 0.259981E+11 | ||||
Minimum of Months | 0.918774E+09 | 937.20 | 0.198155E+10 | 1466.95 | ||
Maximum of Months | 0.109597E+10 | 1525.64 | 0.227025E+10 | 1466.95 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.167696E+10 | 2367.44 | 02-JAN-08:09 | 0.339723E+10 | 2276.35 | 02-JAN-08:09 |
February | 0.144130E+10 | 2029.67 | 02-FEB-16:00 | 0.307490E+10 | 2276.35 | 01-FEB-08:09 |
March | 0.165887E+10 | 1920.80 | 03-MAR-16:00 | 0.352288E+10 | 2276.35 | 01-MAR-08:09 |
April | 0.145052E+10 | 1454.32 | 03-APR-07:10 | 0.328113E+10 | 2276.35 | 03-APR-07:10 |
May | 0.153322E+10 | 1454.32 | 01-MAY-07:10 | 0.346006E+10 | 2276.35 | 01-MAY-07:10 |
June | 0.151534E+10 | 1454.32 | 01-JUN-07:10 | 0.339359E+10 | 2276.35 | 01-JUN-07:10 |
July | 0.142614E+10 | 1454.32 | 03-JUL-07:10 | 0.334669E+10 | 2276.35 | 03-JUL-07:10 |
August | 0.160921E+10 | 1750.96 | 31-AUG-07:10 | 0.352288E+10 | 2276.35 | 01-AUG-07:10 |
September | 0.146598E+10 | 1777.97 | 19-SEP-07:10 | 0.327931E+10 | 2276.35 | 01-SEP-07:10 |
October | 0.157049E+10 | 2336.74 | 31-OCT-07:10 | 0.339814E+10 | 2276.35 | 02-OCT-07:10 |
November | 0.164222E+10 | 2367.44 | 06-NOV-16:49 | 0.332029E+10 | 2276.35 | 01-NOV-07:10 |
December | 0.165365E+10 | 2367.44 | 01-DEC-16:19 | 0.334578E+10 | 2276.35 | 01-DEC-08:09 |
Annual Sum or Average | 0.186439E+11 | 0.403429E+11 | ||||
Minimum of Months | 0.142614E+10 | 1454.32 | 0.307490E+10 | 2276.35 | ||
Maximum of Months | 0.167696E+10 | 2367.44 | 0.352288E+10 | 2276.35 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.109472E+10 | 1525.64 | 02-JAN-08:09 | 0.218926E+10 | 1466.94 | 02-JAN-08:09 |
February | 0.933132E+09 | 1273.71 | 01-FEB-08:09 | 0.198154E+10 | 1466.94 | 01-FEB-08:09 |
March | 0.107187E+10 | 1284.81 | 13-MAR-07:10 | 0.227023E+10 | 1466.94 | 01-MAR-08:09 |
April | 0.933574E+09 | 1040.51 | 03-APR-07:10 | 0.211444E+10 | 1466.94 | 03-APR-07:10 |
May | 0.985275E+09 | 937.20 | 01-MAY-07:10 | 0.222974E+10 | 1466.94 | 01-MAY-07:10 |
June | 0.972898E+09 | 937.20 | 01-JUN-07:10 | 0.218691E+10 | 1466.94 | 01-JUN-07:10 |
July | 0.915807E+09 | 937.20 | 03-JUL-07:10 | 0.215669E+10 | 1466.94 | 03-JUL-07:10 |
August | 0.103546E+10 | 1164.31 | 31-AUG-07:10 | 0.227023E+10 | 1466.94 | 01-AUG-07:10 |
September | 0.945226E+09 | 1196.72 | 19-SEP-07:10 | 0.211327E+10 | 1466.94 | 01-SEP-07:10 |
October | 0.101974E+10 | 1510.24 | 31-OCT-07:10 | 0.218984E+10 | 1466.94 | 02-OCT-07:10 |
November | 0.106638E+10 | 1525.64 | 06-NOV-16:49 | 0.213967E+10 | 1466.94 | 01-NOV-07:10 |
December | 0.107714E+10 | 1525.64 | 01-DEC-16:19 | 0.215610E+10 | 1466.94 | 01-DEC-08:09 |
Annual Sum or Average | 0.120512E+11 | 0.259979E+11 | ||||
Minimum of Months | 0.915807E+09 | 937.20 | 0.198154E+10 | 1466.94 | ||
Maximum of Months | 0.109472E+10 | 1525.64 | 0.227023E+10 | 1466.94 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.172662E+10 | 2367.39 | 02-JAN-08:09 | 0.339718E+10 | 2276.32 | 02-JAN-08:09 |
February | 0.146147E+10 | 2118.34 | 01-FEB-16:00 | 0.307485E+10 | 2276.32 | 01-FEB-08:09 |
March | 0.166839E+10 | 1966.48 | 03-MAR-16:00 | 0.352283E+10 | 2276.32 | 01-MAR-08:09 |
April | 0.144906E+10 | 1454.29 | 03-APR-07:10 | 0.328108E+10 | 2276.32 | 03-APR-07:10 |
May | 0.152793E+10 | 1454.29 | 01-MAY-07:10 | 0.346000E+10 | 2276.32 | 01-MAY-07:10 |
June | 0.150877E+10 | 1454.29 | 01-JUN-07:10 | 0.339353E+10 | 2276.32 | 01-JUN-07:10 |
July | 0.142067E+10 | 1454.29 | 03-JUL-07:10 | 0.334664E+10 | 2276.32 | 03-JUL-07:10 |
August | 0.160702E+10 | 1786.98 | 31-AUG-07:10 | 0.352283E+10 | 2276.32 | 01-AUG-07:10 |
September | 0.146742E+10 | 1820.60 | 19-SEP-07:10 | 0.327926E+10 | 2276.32 | 01-SEP-07:10 |
October | 0.158938E+10 | 2343.17 | 31-OCT-07:10 | 0.339809E+10 | 2276.32 | 02-OCT-07:10 |
November | 0.167631E+10 | 2367.39 | 06-NOV-16:49 | 0.332024E+10 | 2276.32 | 01-NOV-07:10 |
December | 0.169653E+10 | 2367.39 | 01-DEC-16:19 | 0.334573E+10 | 2276.32 | 01-DEC-08:09 |
Annual Sum or Average | 0.187996E+11 | 0.403423E+11 | ||||
Minimum of Months | 0.142067E+10 | 1454.29 | 0.307485E+10 | 2276.32 | ||
Maximum of Months | 0.172662E+10 | 2367.39 | 0.352283E+10 | 2276.32 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.109660E+10 | 1525.64 | 02-JAN-08:09 | 0.218927E+10 | 1466.95 | 02-JAN-08:09 |
February | 0.937558E+09 | 1383.59 | 02-FEB-16:00 | 0.198155E+10 | 1466.95 | 01-FEB-08:09 |
March | 0.107212E+10 | 1279.56 | 03-MAR-16:00 | 0.227025E+10 | 1466.95 | 01-MAR-08:09 |
April | 0.934674E+09 | 937.20 | 03-APR-07:10 | 0.211446E+10 | 1466.95 | 03-APR-07:10 |
May | 0.987968E+09 | 937.20 | 01-MAY-07:10 | 0.222976E+10 | 1466.95 | 01-MAY-07:10 |
June | 0.976266E+09 | 937.20 | 01-JUN-07:10 | 0.218692E+10 | 1466.95 | 01-JUN-07:10 |
July | 0.918934E+09 | 937.20 | 03-JUL-07:10 | 0.215670E+10 | 1466.95 | 03-JUL-07:10 |
August | 0.103735E+10 | 1092.37 | 31-AUG-07:10 | 0.227025E+10 | 1466.95 | 01-AUG-07:10 |
September | 0.945592E+09 | 1091.88 | 19-SEP-07:10 | 0.211328E+10 | 1466.95 | 01-SEP-07:10 |
October | 0.101770E+10 | 1505.07 | 31-OCT-07:10 | 0.218986E+10 | 1466.95 | 02-OCT-07:10 |
November | 0.107075E+10 | 1525.64 | 06-NOV-16:49 | 0.213969E+10 | 1466.95 | 01-NOV-07:10 |
December | 0.108007E+10 | 1525.64 | 01-DEC-16:19 | 0.215612E+10 | 1466.95 | 01-DEC-08:09 |
Annual Sum or Average | 0.120756E+11 | 0.259981E+11 | ||||
Minimum of Months | 0.918934E+09 | 937.20 | 0.198155E+10 | 1466.95 | ||
Maximum of Months | 0.109660E+10 | 1525.64 | 0.227025E+10 | 1466.95 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.167811E+10 | 2367.44 | 02-JAN-08:09 | 0.339723E+10 | 2276.35 | 02-JAN-08:09 |
February | 0.144202E+10 | 2041.32 | 02-FEB-16:00 | 0.307490E+10 | 2276.35 | 01-FEB-08:09 |
March | 0.165976E+10 | 1934.51 | 03-MAR-16:00 | 0.352288E+10 | 2276.35 | 01-MAR-08:09 |
April | 0.145108E+10 | 1454.32 | 03-APR-07:10 | 0.328113E+10 | 2276.35 | 03-APR-07:10 |
May | 0.153388E+10 | 1454.32 | 01-MAY-07:10 | 0.346006E+10 | 2276.35 | 01-MAY-07:10 |
June | 0.151592E+10 | 1454.32 | 01-JUN-07:10 | 0.339359E+10 | 2276.35 | 01-JUN-07:10 |
July | 0.142659E+10 | 1454.32 | 03-JUL-07:10 | 0.334669E+10 | 2276.35 | 03-JUL-07:10 |
August | 0.160999E+10 | 1769.36 | 31-AUG-07:10 | 0.352288E+10 | 2276.35 | 01-AUG-07:10 |
September | 0.146670E+10 | 1795.57 | 19-SEP-07:10 | 0.327931E+10 | 2276.35 | 01-SEP-07:10 |
October | 0.157186E+10 | 2337.74 | 31-OCT-07:10 | 0.339814E+10 | 2276.35 | 02-OCT-07:10 |
November | 0.164363E+10 | 2367.44 | 06-NOV-16:49 | 0.332029E+10 | 2276.35 | 01-NOV-07:10 |
December | 0.165529E+10 | 2367.44 | 01-DEC-16:19 | 0.334578E+10 | 2276.35 | 01-DEC-08:09 |
Annual Sum or Average | 0.186548E+11 | 0.403429E+11 | ||||
Minimum of Months | 0.142659E+10 | 1454.32 | 0.307490E+10 | 2276.35 | ||
Maximum of Months | 0.167811E+10 | 2367.44 | 0.352288E+10 | 2276.35 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.109526E+10 | 1525.64 | 02-JAN-08:09 | 0.218926E+10 | 1466.94 | 02-JAN-08:09 |
February | 0.933399E+09 | 1277.22 | 02-FEB-16:00 | 0.198154E+10 | 1466.94 | 01-FEB-08:09 |
March | 0.107229E+10 | 1286.66 | 13-MAR-07:10 | 0.227023E+10 | 1466.94 | 01-MAR-08:09 |
April | 0.933829E+09 | 1044.15 | 03-APR-07:10 | 0.211444E+10 | 1466.94 | 03-APR-07:10 |
May | 0.985393E+09 | 937.20 | 01-MAY-07:10 | 0.222974E+10 | 1466.94 | 01-MAY-07:10 |
June | 0.973066E+09 | 937.20 | 01-JUN-07:10 | 0.218691E+10 | 1466.94 | 01-JUN-07:10 |
July | 0.915935E+09 | 937.20 | 03-JUL-07:10 | 0.215669E+10 | 1466.94 | 03-JUL-07:10 |
August | 0.103566E+10 | 1167.02 | 31-AUG-07:10 | 0.227023E+10 | 1466.94 | 01-AUG-07:10 |
September | 0.945521E+09 | 1199.20 | 19-SEP-07:10 | 0.211327E+10 | 1466.94 | 01-SEP-07:10 |
October | 0.102017E+10 | 1510.37 | 31-OCT-07:10 | 0.218984E+10 | 1466.94 | 02-OCT-07:10 |
November | 0.106684E+10 | 1525.64 | 06-NOV-16:49 | 0.213967E+10 | 1466.94 | 01-NOV-07:10 |
December | 0.107786E+10 | 1525.64 | 01-DEC-16:19 | 0.215610E+10 | 1466.94 | 01-DEC-08:09 |
Annual Sum or Average | 0.120552E+11 | 0.259979E+11 | ||||
Minimum of Months | 0.915935E+09 | 937.20 | 0.198154E+10 | 1466.94 | ||
Maximum of Months | 0.109526E+10 | 1525.64 | 0.227023E+10 | 1466.94 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.172666E+10 | 2367.39 | 02-JAN-08:09 | 0.339718E+10 | 2276.32 | 02-JAN-08:09 |
February | 0.146148E+10 | 2118.61 | 01-FEB-16:00 | 0.307485E+10 | 2276.32 | 01-FEB-08:09 |
March | 0.166839E+10 | 1966.10 | 03-MAR-16:00 | 0.352283E+10 | 2276.32 | 01-MAR-08:09 |
April | 0.144905E+10 | 1454.29 | 03-APR-07:10 | 0.328108E+10 | 2276.32 | 03-APR-07:10 |
May | 0.152793E+10 | 1454.29 | 01-MAY-07:10 | 0.346000E+10 | 2276.32 | 01-MAY-07:10 |
June | 0.150877E+10 | 1454.29 | 01-JUN-07:10 | 0.339353E+10 | 2276.32 | 01-JUN-07:10 |
July | 0.142067E+10 | 1454.29 | 03-JUL-07:10 | 0.334664E+10 | 2276.32 | 03-JUL-07:10 |
August | 0.160701E+10 | 1786.40 | 31-AUG-07:10 | 0.352283E+10 | 2276.32 | 01-AUG-07:10 |
September | 0.146741E+10 | 1820.09 | 19-SEP-07:10 | 0.327926E+10 | 2276.32 | 01-SEP-07:10 |
October | 0.158946E+10 | 2343.14 | 31-OCT-07:10 | 0.339809E+10 | 2276.32 | 02-OCT-07:10 |
November | 0.167630E+10 | 2367.39 | 06-NOV-16:49 | 0.332024E+10 | 2276.32 | 01-NOV-07:10 |
December | 0.169654E+10 | 2367.39 | 01-DEC-16:19 | 0.334573E+10 | 2276.32 | 01-DEC-08:09 |
Annual Sum or Average | 0.187997E+11 | 0.403423E+11 | ||||
Minimum of Months | 0.142067E+10 | 1454.29 | 0.307485E+10 | 2276.32 | ||
Maximum of Months | 0.172666E+10 | 2367.39 | 0.352283E+10 | 2276.32 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.109662E+10 | 1525.64 | 02-JAN-08:09 | 0.218927E+10 | 1466.95 | 02-JAN-08:09 |
February | 0.937567E+09 | 1383.49 | 02-FEB-16:00 | 0.198155E+10 | 1466.95 | 01-FEB-08:09 |
March | 0.107212E+10 | 1279.33 | 03-MAR-16:00 | 0.227025E+10 | 1466.95 | 01-MAR-08:09 |
April | 0.934675E+09 | 937.20 | 03-APR-07:10 | 0.211446E+10 | 1466.95 | 03-APR-07:10 |
May | 0.987992E+09 | 937.20 | 01-MAY-07:10 | 0.222976E+10 | 1466.95 | 01-MAY-07:10 |
June | 0.976267E+09 | 937.20 | 01-JUN-07:10 | 0.218692E+10 | 1466.95 | 01-JUN-07:10 |
July | 0.918936E+09 | 937.20 | 03-JUL-07:10 | 0.215670E+10 | 1466.95 | 03-JUL-07:10 |
August | 0.103735E+10 | 1092.08 | 31-AUG-07:10 | 0.227025E+10 | 1466.95 | 01-AUG-07:10 |
September | 0.945593E+09 | 1091.65 | 19-SEP-07:10 | 0.211328E+10 | 1466.95 | 01-SEP-07:10 |
October | 0.101765E+10 | 1505.06 | 31-OCT-07:10 | 0.218986E+10 | 1466.95 | 02-OCT-07:10 |
November | 0.107075E+10 | 1525.64 | 06-NOV-16:49 | 0.213969E+10 | 1466.95 | 01-NOV-07:10 |
December | 0.108008E+10 | 1525.64 | 01-DEC-16:19 | 0.215612E+10 | 1466.95 | 01-DEC-08:09 |
Annual Sum or Average | 0.120756E+11 | 0.259981E+11 | ||||
Minimum of Months | 0.918936E+09 | 937.20 | 0.198155E+10 | 1466.95 | ||
Maximum of Months | 0.109662E+10 | 1525.64 | 0.227025E+10 | 1466.95 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.167821E+10 | 2367.44 | 02-JAN-08:09 | 0.339723E+10 | 2276.35 | 02-JAN-08:09 |
February | 0.144202E+10 | 2041.21 | 02-FEB-16:00 | 0.307490E+10 | 2276.35 | 01-FEB-08:09 |
March | 0.165975E+10 | 1934.14 | 03-MAR-16:00 | 0.352288E+10 | 2276.35 | 01-MAR-08:09 |
April | 0.145108E+10 | 1454.32 | 03-APR-07:10 | 0.328113E+10 | 2276.35 | 03-APR-07:10 |
May | 0.153388E+10 | 1454.32 | 01-MAY-07:10 | 0.346006E+10 | 2276.35 | 01-MAY-07:10 |
June | 0.151592E+10 | 1454.32 | 01-JUN-07:10 | 0.339359E+10 | 2276.35 | 01-JUN-07:10 |
July | 0.142659E+10 | 1454.32 | 03-JUL-07:10 | 0.334669E+10 | 2276.35 | 03-JUL-07:10 |
August | 0.160999E+10 | 1768.79 | 31-AUG-07:10 | 0.352288E+10 | 2276.35 | 01-AUG-07:10 |
September | 0.146670E+10 | 1795.08 | 19-SEP-07:10 | 0.327931E+10 | 2276.35 | 01-SEP-07:10 |
October | 0.157186E+10 | 2337.72 | 31-OCT-07:10 | 0.339814E+10 | 2276.35 | 02-OCT-07:10 |
November | 0.164363E+10 | 2367.44 | 06-NOV-16:49 | 0.332029E+10 | 2276.35 | 01-NOV-07:10 |
December | 0.165530E+10 | 2367.44 | 01-DEC-16:19 | 0.334578E+10 | 2276.35 | 01-DEC-08:09 |
Annual Sum or Average | 0.186549E+11 | 0.403429E+11 | ||||
Minimum of Months | 0.142659E+10 | 1454.32 | 0.307490E+10 | 2276.35 | ||
Maximum of Months | 0.167821E+10 | 2367.44 | 0.352288E+10 | 2276.35 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.109533E+10 | 1525.64 | 02-JAN-08:09 | 0.218926E+10 | 1466.94 | 02-JAN-08:09 |
February | 0.933404E+09 | 1277.22 | 02-FEB-16:00 | 0.198154E+10 | 1466.94 | 01-FEB-08:09 |
March | 0.107229E+10 | 1286.45 | 13-MAR-07:10 | 0.227023E+10 | 1466.94 | 01-MAR-08:09 |
April | 0.933833E+09 | 1043.73 | 03-APR-07:10 | 0.211444E+10 | 1466.94 | 03-APR-07:10 |
May | 0.985396E+09 | 937.20 | 01-MAY-07:10 | 0.222974E+10 | 1466.94 | 01-MAY-07:10 |
June | 0.973068E+09 | 937.20 | 01-JUN-07:10 | 0.218691E+10 | 1466.94 | 01-JUN-07:10 |
July | 0.915937E+09 | 937.20 | 03-JUL-07:10 | 0.215669E+10 | 1466.94 | 03-JUL-07:10 |
August | 0.103566E+10 | 1166.66 | 31-AUG-07:10 | 0.227023E+10 | 1466.94 | 01-AUG-07:10 |
September | 0.945520E+09 | 1198.89 | 19-SEP-07:10 | 0.211327E+10 | 1466.94 | 01-SEP-07:10 |
October | 0.102017E+10 | 1510.36 | 31-OCT-07:10 | 0.218984E+10 | 1466.94 | 02-OCT-07:10 |
November | 0.106684E+10 | 1525.64 | 06-NOV-16:49 | 0.213967E+10 | 1466.94 | 01-NOV-07:10 |
December | 0.107787E+10 | 1525.64 | 01-DEC-16:19 | 0.215610E+10 | 1466.94 | 01-DEC-08:09 |
Annual Sum or Average | 0.120553E+11 | 0.259979E+11 | ||||
Minimum of Months | 0.915937E+09 | 937.20 | 0.198154E+10 | 1466.94 | ||
Maximum of Months | 0.109533E+10 | 1525.64 | 0.227023E+10 | 1466.94 |
Report: ZoneElectricSummaryMonthly
For: DATACENTER_BOT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.497722E+09 | 520.85 | 02-JAN-08:09 | 0.521915E+10 | 1948.61 | 01-JAN-00:10 |
February | 0.451470E+09 | 520.85 | 01-FEB-08:09 | 0.942813E+10 | 3897.21 | 01-FEB-00:10 |
March | 0.536472E+09 | 520.85 | 01-MAR-08:09 | 0.156645E+11 | 7794.42 | 31-MAR-23:10 |
April | 0.479179E+09 | 520.85 | 03-APR-07:10 | 0.201821E+11 | 7794.42 | 01-APR-00:10 |
May | 0.517097E+09 | 520.85 | 01-MAY-07:10 | 0.522616E+10 | 3897.21 | 31-MAY-23:10 |
June | 0.514597E+09 | 520.85 | 01-JUN-07:10 | 0.101086E+11 | 5845.82 | 30-JUN-23:10 |
July | 0.481680E+09 | 520.85 | 03-JUL-07:10 | 0.156645E+11 | 7794.42 | 31-JUL-23:10 |
August | 0.536472E+09 | 520.85 | 01-AUG-07:10 | 0.208555E+11 | 7794.42 | 01-AUG-00:10 |
September | 0.479179E+09 | 520.85 | 01-SEP-07:10 | 0.505780E+10 | 3897.21 | 30-SEP-23:10 |
October | 0.497722E+09 | 520.85 | 02-OCT-07:10 | 0.104453E+11 | 5845.82 | 31-OCT-23:10 |
November | 0.491888E+09 | 520.85 | 01-NOV-07:10 | 0.151524E+11 | 5845.82 | 01-NOV-00:10 |
December | 0.481680E+09 | 520.85 | 01-DEC-08:09 | 0.208766E+11 | 7794.42 | 01-DEC-00:10 |
Annual Sum or Average | 0.596516E+10 | 0.153881E+12 | ||||
Minimum of Months | 0.451470E+09 | 520.85 | 0.505780E+10 | 1948.61 | ||
Maximum of Months | 0.536472E+09 | 520.85 | 0.208766E+11 | 7794.42 |
Report: ZoneElectricSummaryMonthly
For: DATACENTER_MID_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.497722E+09 | 520.85 | 02-JAN-08:09 | 0.521915E+10 | 1948.61 | 01-JAN-00:10 |
February | 0.451470E+09 | 520.85 | 01-FEB-08:09 | 0.942813E+10 | 3897.21 | 01-FEB-00:10 |
March | 0.536472E+09 | 520.85 | 01-MAR-08:09 | 0.156645E+11 | 7794.42 | 31-MAR-23:10 |
April | 0.479179E+09 | 520.85 | 03-APR-07:10 | 0.201821E+11 | 7794.42 | 01-APR-00:10 |
May | 0.517097E+09 | 520.85 | 01-MAY-07:10 | 0.522616E+10 | 3897.21 | 31-MAY-23:10 |
June | 0.514597E+09 | 520.85 | 01-JUN-07:10 | 0.101086E+11 | 5845.82 | 30-JUN-23:10 |
July | 0.481680E+09 | 520.85 | 03-JUL-07:10 | 0.156645E+11 | 7794.42 | 31-JUL-23:10 |
August | 0.536472E+09 | 520.85 | 01-AUG-07:10 | 0.208555E+11 | 7794.42 | 01-AUG-00:10 |
September | 0.479179E+09 | 520.85 | 01-SEP-07:10 | 0.505780E+10 | 3897.21 | 30-SEP-23:10 |
October | 0.497722E+09 | 520.85 | 02-OCT-07:10 | 0.104453E+11 | 5845.82 | 31-OCT-23:10 |
November | 0.491888E+09 | 520.85 | 01-NOV-07:10 | 0.151524E+11 | 5845.82 | 01-NOV-00:10 |
December | 0.481680E+09 | 520.85 | 01-DEC-08:09 | 0.208766E+11 | 7794.42 | 01-DEC-00:10 |
Annual Sum or Average | 0.596516E+10 | 0.153881E+12 | ||||
Minimum of Months | 0.451470E+09 | 520.85 | 0.505780E+10 | 1948.61 | ||
Maximum of Months | 0.536472E+09 | 520.85 | 0.208766E+11 | 7794.42 |
Report: ZoneElectricSummaryMonthly
For: DATACENTER_TOP_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.497722E+09 | 520.85 | 02-JAN-08:09 | 0.521915E+10 | 1948.61 | 01-JAN-00:10 |
February | 0.451470E+09 | 520.85 | 01-FEB-08:09 | 0.942813E+10 | 3897.21 | 01-FEB-00:10 |
March | 0.536472E+09 | 520.85 | 01-MAR-08:09 | 0.156645E+11 | 7794.42 | 31-MAR-23:10 |
April | 0.479179E+09 | 520.85 | 03-APR-07:10 | 0.201821E+11 | 7794.42 | 01-APR-00:10 |
May | 0.517097E+09 | 520.85 | 01-MAY-07:10 | 0.522616E+10 | 3897.21 | 31-MAY-23:10 |
June | 0.514597E+09 | 520.85 | 01-JUN-07:10 | 0.101086E+11 | 5845.82 | 30-JUN-23:10 |
July | 0.481680E+09 | 520.85 | 03-JUL-07:10 | 0.156645E+11 | 7794.42 | 31-JUL-23:10 |
August | 0.536472E+09 | 520.85 | 01-AUG-07:10 | 0.208555E+11 | 7794.42 | 01-AUG-00:10 |
September | 0.479179E+09 | 520.85 | 01-SEP-07:10 | 0.505780E+10 | 3897.21 | 30-SEP-23:10 |
October | 0.497722E+09 | 520.85 | 02-OCT-07:10 | 0.104453E+11 | 5845.82 | 31-OCT-23:10 |
November | 0.491888E+09 | 520.85 | 01-NOV-07:10 | 0.151524E+11 | 5845.82 | 01-NOV-00:10 |
December | 0.481680E+09 | 520.85 | 01-DEC-08:09 | 0.208766E+11 | 7794.42 | 01-DEC-00:10 |
Annual Sum or Average | 0.596516E+10 | 0.153881E+12 | ||||
Minimum of Months | 0.451470E+09 | 520.85 | 0.505780E+10 | 1948.61 | ||
Maximum of Months | 0.536472E+09 | 520.85 | 0.208766E+11 | 7794.42 |
Report: ZoneElectricSummaryMonthly
For: DATACENTER_BASEMENT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.565679E+10 | 5919.59 | 02-JAN-08:09 | 0.254202E+12 | 94908.13 | 01-JAN-00:10 |
February | 0.513113E+10 | 5919.59 | 01-FEB-08:09 | 0.459203E+12 | 189816.26 | 01-FEB-00:10 |
March | 0.609720E+10 | 5919.59 | 01-MAR-08:09 | 0.762947E+12 | 379632.52 | 31-MAR-23:10 |
April | 0.544605E+10 | 5919.59 | 03-APR-07:10 | 0.982982E+12 | 379632.52 | 01-APR-00:10 |
May | 0.587700E+10 | 5919.59 | 01-MAY-07:10 | 0.254544E+12 | 189816.26 | 31-MAY-23:10 |
June | 0.584858E+10 | 5919.59 | 01-JUN-07:10 | 0.492345E+12 | 284724.39 | 30-JUN-23:10 |
July | 0.547447E+10 | 5919.59 | 03-JUL-07:10 | 0.762947E+12 | 379632.52 | 31-JUL-23:10 |
August | 0.609720E+10 | 5919.59 | 01-AUG-07:10 | 0.101578E+13 | 379632.52 | 01-AUG-00:10 |
September | 0.544605E+10 | 5919.59 | 01-SEP-07:10 | 0.246344E+12 | 189816.26 | 30-SEP-23:10 |
October | 0.565679E+10 | 5919.59 | 02-OCT-07:10 | 0.508746E+12 | 284724.39 | 31-OCT-23:10 |
November | 0.559049E+10 | 5919.59 | 01-NOV-07:10 | 0.738006E+12 | 284724.39 | 01-NOV-00:10 |
December | 0.547447E+10 | 5919.59 | 01-DEC-08:09 | 0.101681E+13 | 379632.52 | 01-DEC-00:10 |
Annual Sum or Average | 0.677962E+11 | 0.749486E+13 | ||||
Minimum of Months | 0.513113E+10 | 5919.59 | 0.246344E+12 | 94908.13 | ||
Maximum of Months | 0.609720E+10 | 5919.59 | 0.101681E+13 | 379632.52 |
Report: SpaceGainsMonthly
For: BASEMENT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.133902E+11 | 0.200626E+11 | 0.360447E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.121482E+11 | 0.181982E+11 | 0.325565E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.145160E+11 | 0.216246E+11 | 0.360447E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.128805E+11 | 0.193152E+11 | 0.348820E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.139531E+11 | 0.208436E+11 | 0.360447E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.139143E+11 | 0.207428E+11 | 0.348820E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.129193E+11 | 0.194159E+11 | 0.360447E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.145160E+11 | 0.216246E+11 | 0.360447E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.128805E+11 | 0.193152E+11 | 0.348820E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.133902E+11 | 0.200626E+11 | 0.360447E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.132595E+11 | 0.198274E+11 | 0.348820E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.129193E+11 | 0.194159E+11 | 0.360447E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.160687E+12 | 0.240449E+12 | 0.424397E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.121482E+11 | 0.181982E+11 | 0.325565E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.145160E+11 | 0.216246E+11 | 0.360447E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.120254E+11 | 0.180176E+11 | 0.270551E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.109099E+11 | 0.163433E+11 | 0.244881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.130364E+11 | 0.194204E+11 | 0.280558E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.115676E+11 | 0.173464E+11 | 0.261305E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.125309E+11 | 0.187190E+11 | 0.275555E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.124961E+11 | 0.186285E+11 | 0.270261E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.116025E+11 | 0.174369E+11 | 0.266527E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.130364E+11 | 0.194204E+11 | 0.280558E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.115676E+11 | 0.173464E+11 | 0.261160E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.120254E+11 | 0.180176E+11 | 0.270624E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.119080E+11 | 0.178064E+11 | 0.264424E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.116025E+11 | 0.174369E+11 | 0.266454E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.144308E+12 | 0.215940E+12 | 0.321286E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.109099E+11 | 0.163433E+11 | 0.244881E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.130364E+11 | 0.194204E+11 | 0.280558E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: CORE_MID
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.120254E+11 | 0.180176E+11 | 0.270550E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.109099E+11 | 0.163433E+11 | 0.244880E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.130364E+11 | 0.194204E+11 | 0.280557E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.115676E+11 | 0.173464E+11 | 0.261304E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.125309E+11 | 0.187190E+11 | 0.275554E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.124961E+11 | 0.186285E+11 | 0.270260E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.116025E+11 | 0.174369E+11 | 0.266526E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.130364E+11 | 0.194204E+11 | 0.280557E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.115676E+11 | 0.173464E+11 | 0.261159E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.120254E+11 | 0.180176E+11 | 0.270623E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.119080E+11 | 0.178064E+11 | 0.264423E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.116025E+11 | 0.174369E+11 | 0.266453E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.144308E+12 | 0.215940E+12 | 0.321285E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.109099E+11 | 0.163433E+11 | 0.244880E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.130364E+11 | 0.194204E+11 | 0.280557E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: CORE_TOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.120254E+11 | 0.180176E+11 | 0.270550E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.109099E+11 | 0.163433E+11 | 0.244880E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.130364E+11 | 0.194204E+11 | 0.280557E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.115676E+11 | 0.173464E+11 | 0.261304E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.125309E+11 | 0.187190E+11 | 0.275554E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.124961E+11 | 0.186285E+11 | 0.270260E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.116025E+11 | 0.174369E+11 | 0.266526E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.130364E+11 | 0.194204E+11 | 0.280557E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.115676E+11 | 0.173464E+11 | 0.261159E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.120254E+11 | 0.180176E+11 | 0.270623E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.119080E+11 | 0.178064E+11 | 0.264423E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.116025E+11 | 0.174369E+11 | 0.266453E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.144308E+12 | 0.215940E+12 | 0.321285E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.109099E+11 | 0.163433E+11 | 0.244880E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.130364E+11 | 0.194204E+11 | 0.280557E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.150991E+10 | 0.172293E+10 | 0.339718E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.165393E+10 |
February | 0.136985E+10 | 0.145986E+10 | 0.307485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147171E+10 |
March | 0.163685E+10 | 0.166660E+10 | 0.352283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101899E+10 |
April | 0.145243E+10 | 0.144861E+10 | 0.328108E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 914583.85 | 0.980415E+09 |
May | 0.157338E+10 | 0.152729E+10 | 0.346000E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2792397.80 | 0.460432E+09 |
June | 0.156900E+10 | 0.150838E+10 | 0.339353E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11637082.04 | 0.248393E+09 |
July | 0.145680E+10 | 0.142029E+10 | 0.334664E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13411538.90 | 0.172597E+09 |
August | 0.163685E+10 | 0.160642E+10 | 0.352283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4306487.36 | 0.245616E+09 |
September | 0.145243E+10 | 0.146676E+10 | 0.327926E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 140601.74 | 0.440842E+09 |
October | 0.150991E+10 | 0.158733E+10 | 0.339809E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.690946E+09 |
November | 0.149516E+10 | 0.167342E+10 | 0.332024E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121524E+10 |
December | 0.145680E+10 | 0.169367E+10 | 0.334573E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180115E+10 |
Annual Sum or Average | 0.181194E+11 | 0.187816E+11 | 0.403423E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 33202691.69 | 0.104003E+11 |
Minimum of Months | 0.136985E+10 | 0.142029E+10 | 0.307485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.172597E+09 |
Maximum of Months | 0.163685E+10 | 0.172293E+10 | 0.352283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13411538.90 | 0.180115E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.973041E+09 | 0.109597E+10 | 0.218927E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109912E+10 |
February | 0.882782E+09 | 0.937136E+09 | 0.198155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.979105E+09 |
March | 0.105485E+10 | 0.107173E+10 | 0.227025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.674065E+09 |
April | 0.936002E+09 | 0.934499E+09 | 0.211446E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1523929.37 | 0.637739E+09 |
May | 0.101394E+10 | 0.987735E+09 | 0.222976E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1922834.17 | 0.302322E+09 |
June | 0.101113E+10 | 0.976118E+09 | 0.218692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9042798.72 | 0.157549E+09 |
July | 0.938820E+09 | 0.918774E+09 | 0.215670E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10151985.14 | 0.100532E+09 |
August | 0.105485E+10 | 0.103720E+10 | 0.227025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3078471.87 | 0.148254E+09 |
September | 0.936002E+09 | 0.945381E+09 | 0.211328E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 96256.31 | 0.285213E+09 |
October | 0.973041E+09 | 0.101720E+10 | 0.218986E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.446829E+09 |
November | 0.963541E+09 | 0.107026E+10 | 0.213969E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.791413E+09 |
December | 0.938820E+09 | 0.107948E+10 | 0.215612E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118751E+10 |
Annual Sum or Average | 0.116768E+11 | 0.120715E+11 | 0.259981E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 25816275.57 | 0.680966E+10 |
Minimum of Months | 0.882782E+09 | 0.918774E+09 | 0.198155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100532E+09 |
Maximum of Months | 0.105485E+10 | 0.109597E+10 | 0.227025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10151985.14 | 0.118751E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.150994E+10 | 0.167696E+10 | 0.339723E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.165552E+10 |
February | 0.136988E+10 | 0.144130E+10 | 0.307490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148895E+10 |
March | 0.163688E+10 | 0.165887E+10 | 0.352288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102766E+10 |
April | 0.145246E+10 | 0.145052E+10 | 0.328113E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 158375.42 | 0.970832E+09 |
May | 0.157341E+10 | 0.153322E+10 | 0.346006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2794741.83 | 0.455017E+09 |
June | 0.156904E+10 | 0.151534E+10 | 0.339359E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12164281.43 | 0.238110E+09 |
July | 0.145684E+10 | 0.142614E+10 | 0.334669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13354110.74 | 0.163366E+09 |
August | 0.163688E+10 | 0.160921E+10 | 0.352288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4276881.06 | 0.242896E+09 |
September | 0.145246E+10 | 0.146598E+10 | 0.327931E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 139169.17 | 0.446070E+09 |
October | 0.150994E+10 | 0.157049E+10 | 0.339814E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.682222E+09 |
November | 0.149520E+10 | 0.164222E+10 | 0.332029E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119290E+10 |
December | 0.145684E+10 | 0.165365E+10 | 0.334578E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.179394E+10 |
Annual Sum or Average | 0.181198E+11 | 0.186439E+11 | 0.403429E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 32887559.64 | 0.103575E+11 |
Minimum of Months | 0.136988E+10 | 0.142614E+10 | 0.307490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.163366E+09 |
Maximum of Months | 0.163688E+10 | 0.167696E+10 | 0.352288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13354110.74 | 0.179394E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.973041E+09 | 0.109472E+10 | 0.218926E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.113074E+10 |
February | 0.882782E+09 | 0.933132E+09 | 0.198154E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102685E+10 |
March | 0.105485E+10 | 0.107187E+10 | 0.227023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.721243E+09 |
April | 0.936002E+09 | 0.933574E+09 | 0.211444E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.712422E+09 |
May | 0.101394E+10 | 0.985275E+09 | 0.222974E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1861672.36 | 0.323985E+09 |
June | 0.101113E+10 | 0.972898E+09 | 0.218691E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7726068.90 | 0.177698E+09 |
July | 0.938820E+09 | 0.915807E+09 | 0.215669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8447651.60 | 0.126234E+09 |
August | 0.105485E+10 | 0.103546E+10 | 0.227023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2822774.77 | 0.182632E+09 |
September | 0.936002E+09 | 0.945226E+09 | 0.211327E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 93659.35 | 0.306789E+09 |
October | 0.973041E+09 | 0.101974E+10 | 0.218984E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.484860E+09 |
November | 0.963541E+09 | 0.106638E+10 | 0.213967E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.855587E+09 |
December | 0.938820E+09 | 0.107714E+10 | 0.215610E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126719E+10 |
Annual Sum or Average | 0.116768E+11 | 0.120512E+11 | 0.259979E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 20951826.98 | 0.731623E+10 |
Minimum of Months | 0.882782E+09 | 0.915807E+09 | 0.198154E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126234E+09 |
Maximum of Months | 0.105485E+10 | 0.109472E+10 | 0.227023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8447651.60 | 0.126719E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.150991E+10 | 0.172662E+10 | 0.339718E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.365529E+10 |
February | 0.136985E+10 | 0.146147E+10 | 0.307485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.313591E+10 |
March | 0.163685E+10 | 0.166839E+10 | 0.352283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.218553E+10 |
April | 0.145243E+10 | 0.144906E+10 | 0.328108E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5191369.27 | 0.202820E+10 |
May | 0.157338E+10 | 0.152793E+10 | 0.346000E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6205313.42 | 0.101889E+10 |
June | 0.156900E+10 | 0.150877E+10 | 0.339353E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26262151.85 | 0.557284E+09 |
July | 0.145680E+10 | 0.142067E+10 | 0.334664E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30533507.86 | 0.407396E+09 |
August | 0.163685E+10 | 0.160702E+10 | 0.352283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10744841.53 | 0.551592E+09 |
September | 0.145243E+10 | 0.146742E+10 | 0.327926E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 300629.70 | 0.950213E+09 |
October | 0.150991E+10 | 0.158938E+10 | 0.339809E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142012E+10 |
November | 0.149516E+10 | 0.167631E+10 | 0.332024E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.250411E+10 |
December | 0.145680E+10 | 0.169653E+10 | 0.334573E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.389553E+10 |
Annual Sum or Average | 0.181194E+11 | 0.187996E+11 | 0.403423E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 79237813.64 | 0.223101E+11 |
Minimum of Months | 0.136985E+10 | 0.142067E+10 | 0.307485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.407396E+09 |
Maximum of Months | 0.163685E+10 | 0.172662E+10 | 0.352283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30533507.86 | 0.389553E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.715730E+09 | 0.109660E+10 | 0.218927E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.244589E+10 |
February | 0.649041E+09 | 0.937558E+09 | 0.198155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.210501E+10 |
March | 0.773965E+09 | 0.107212E+10 | 0.227025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147938E+10 |
April | 0.688021E+09 | 0.934674E+09 | 0.211446E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4556073.69 | 0.138769E+10 |
May | 0.744847E+09 | 0.987968E+09 | 0.222976E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4353505.50 | 0.683388E+09 |
June | 0.742030E+09 | 0.976266E+09 | 0.218692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19132266.39 | 0.367430E+09 |
July | 0.690839E+09 | 0.918934E+09 | 0.215670E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21550316.26 | 0.260497E+09 |
August | 0.773965E+09 | 0.103735E+10 | 0.227025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7042624.39 | 0.366192E+09 |
September | 0.688021E+09 | 0.945592E+09 | 0.211328E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 208322.63 | 0.625386E+09 |
October | 0.715730E+09 | 0.101770E+10 | 0.218986E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.949129E+09 |
November | 0.708685E+09 | 0.107075E+10 | 0.213969E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.167464E+10 |
December | 0.690839E+09 | 0.108007E+10 | 0.215612E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.260290E+10 |
Annual Sum or Average | 0.858171E+10 | 0.120756E+11 | 0.259981E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 56843108.86 | 0.149475E+11 |
Minimum of Months | 0.649041E+09 | 0.918934E+09 | 0.198155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.260497E+09 |
Maximum of Months | 0.773965E+09 | 0.109660E+10 | 0.227025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21550316.26 | 0.260290E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.150994E+10 | 0.167811E+10 | 0.339723E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.371283E+10 |
February | 0.136988E+10 | 0.144202E+10 | 0.307490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.328596E+10 |
March | 0.163688E+10 | 0.165976E+10 | 0.352288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.231082E+10 |
April | 0.145246E+10 | 0.145108E+10 | 0.328113E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 117504.73 | 0.215190E+10 |
May | 0.157341E+10 | 0.153388E+10 | 0.346006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6225113.46 | 0.103867E+10 |
June | 0.156904E+10 | 0.151592E+10 | 0.339359E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26777175.42 | 0.546593E+09 |
July | 0.145684E+10 | 0.142659E+10 | 0.334669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29609302.00 | 0.404445E+09 |
August | 0.163688E+10 | 0.160999E+10 | 0.352288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9579308.09 | 0.581044E+09 |
September | 0.145246E+10 | 0.146670E+10 | 0.327931E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 273329.94 | 0.101228E+10 |
October | 0.150994E+10 | 0.157186E+10 | 0.339814E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150819E+10 |
November | 0.149520E+10 | 0.164363E+10 | 0.332029E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.259708E+10 |
December | 0.145684E+10 | 0.165529E+10 | 0.334578E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.395834E+10 |
Annual Sum or Average | 0.181198E+11 | 0.186548E+11 | 0.403429E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 72581733.65 | 0.231082E+11 |
Minimum of Months | 0.136988E+10 | 0.142659E+10 | 0.307490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.404445E+09 |
Maximum of Months | 0.163688E+10 | 0.167811E+10 | 0.352288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29609302.00 | 0.395834E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.973041E+09 | 0.109526E+10 | 0.218926E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.245963E+10 |
February | 0.882782E+09 | 0.933399E+09 | 0.198154E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213969E+10 |
March | 0.105485E+10 | 0.107229E+10 | 0.227023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150961E+10 |
April | 0.936002E+09 | 0.933829E+09 | 0.211444E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1023.48 | 0.141908E+10 |
May | 0.101394E+10 | 0.985393E+09 | 0.222974E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4146762.20 | 0.710670E+09 |
June | 0.101113E+10 | 0.973066E+09 | 0.218691E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19151639.49 | 0.378329E+09 |
July | 0.938820E+09 | 0.915935E+09 | 0.215669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20476934.47 | 0.289234E+09 |
August | 0.105485E+10 | 0.103566E+10 | 0.227023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7272036.10 | 0.389643E+09 |
September | 0.936002E+09 | 0.945521E+09 | 0.211327E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 264093.66 | 0.645043E+09 |
October | 0.973041E+09 | 0.102017E+10 | 0.218984E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.971962E+09 |
November | 0.963541E+09 | 0.106684E+10 | 0.213967E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.169917E+10 |
December | 0.938820E+09 | 0.107786E+10 | 0.215610E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.262603E+10 |
Annual Sum or Average | 0.116768E+11 | 0.120552E+11 | 0.259979E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 51312489.41 | 0.152381E+11 |
Minimum of Months | 0.882782E+09 | 0.915935E+09 | 0.198154E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.289234E+09 |
Maximum of Months | 0.105485E+10 | 0.109526E+10 | 0.227023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20476934.47 | 0.262603E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.150991E+10 | 0.172666E+10 | 0.339718E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.450169E+10 |
February | 0.136985E+10 | 0.146148E+10 | 0.307485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.383885E+10 |
March | 0.163685E+10 | 0.166839E+10 | 0.352283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.260501E+10 |
April | 0.145243E+10 | 0.144905E+10 | 0.328108E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9232450.38 | 0.230108E+10 |
May | 0.157338E+10 | 0.152793E+10 | 0.346000E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7306163.12 | 0.118128E+10 |
June | 0.156900E+10 | 0.150877E+10 | 0.339353E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32802398.91 | 0.654276E+09 |
July | 0.145680E+10 | 0.142067E+10 | 0.334664E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36652170.67 | 0.486148E+09 |
August | 0.163685E+10 | 0.160701E+10 | 0.352283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14055768.07 | 0.649262E+09 |
September | 0.145243E+10 | 0.146741E+10 | 0.327926E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 339664.58 | 0.107610E+10 |
October | 0.150991E+10 | 0.158946E+10 | 0.339809E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.158887E+10 |
November | 0.149516E+10 | 0.167630E+10 | 0.332024E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.296684E+10 |
December | 0.145680E+10 | 0.169654E+10 | 0.334573E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.478083E+10 |
Annual Sum or Average | 0.181194E+11 | 0.187997E+11 | 0.403423E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100389E+09 | 0.266302E+11 |
Minimum of Months | 0.136985E+10 | 0.142067E+10 | 0.307485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.486148E+09 |
Maximum of Months | 0.163685E+10 | 0.172666E+10 | 0.352283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36652170.67 | 0.478083E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.973041E+09 | 0.109662E+10 | 0.218927E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.301788E+10 |
February | 0.882782E+09 | 0.937567E+09 | 0.198155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.257207E+10 |
March | 0.105485E+10 | 0.107212E+10 | 0.227025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.176249E+10 |
April | 0.936002E+09 | 0.934675E+09 | 0.211446E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6113878.83 | 0.159638E+10 |
May | 0.101394E+10 | 0.987992E+09 | 0.222976E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5028302.08 | 0.815661E+09 |
June | 0.101113E+10 | 0.976267E+09 | 0.218692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22501285.81 | 0.445671E+09 |
July | 0.938820E+09 | 0.918936E+09 | 0.215670E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24437277.33 | 0.320677E+09 |
August | 0.105485E+10 | 0.103735E+10 | 0.227025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8106464.00 | 0.449088E+09 |
September | 0.936002E+09 | 0.945593E+09 | 0.211328E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 228033.88 | 0.738442E+09 |
October | 0.973041E+09 | 0.101765E+10 | 0.218986E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108214E+10 |
November | 0.963541E+09 | 0.107075E+10 | 0.213969E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.198354E+10 |
December | 0.938820E+09 | 0.108008E+10 | 0.215612E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.320221E+10 |
Annual Sum or Average | 0.116768E+11 | 0.120756E+11 | 0.259981E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 66415241.93 | 0.179863E+11 |
Minimum of Months | 0.882782E+09 | 0.918936E+09 | 0.198155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.320677E+09 |
Maximum of Months | 0.105485E+10 | 0.109662E+10 | 0.227025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24437277.33 | 0.320221E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.150994E+10 | 0.167821E+10 | 0.339723E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.454860E+10 |
February | 0.136988E+10 | 0.144202E+10 | 0.307490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.394309E+10 |
March | 0.163688E+10 | 0.165975E+10 | 0.352288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.274083E+10 |
April | 0.145246E+10 | 0.145108E+10 | 0.328113E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 211179.70 | 0.247017E+10 |
May | 0.157341E+10 | 0.153388E+10 | 0.346006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7326959.35 | 0.122920E+10 |
June | 0.156904E+10 | 0.151592E+10 | 0.339359E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32037892.20 | 0.651736E+09 |
July | 0.145684E+10 | 0.142659E+10 | 0.334669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34724628.82 | 0.491344E+09 |
August | 0.163688E+10 | 0.160999E+10 | 0.352288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11309127.58 | 0.703502E+09 |
September | 0.145246E+10 | 0.146670E+10 | 0.327931E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 322530.31 | 0.119242E+10 |
October | 0.150994E+10 | 0.157186E+10 | 0.339814E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.171960E+10 |
November | 0.149520E+10 | 0.164363E+10 | 0.332029E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.303960E+10 |
December | 0.145684E+10 | 0.165530E+10 | 0.334578E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.482625E+10 |
Annual Sum or Average | 0.181198E+11 | 0.186549E+11 | 0.403429E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 85932317.97 | 0.275563E+11 |
Minimum of Months | 0.136988E+10 | 0.142659E+10 | 0.307490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.491344E+09 |
Maximum of Months | 0.163688E+10 | 0.167821E+10 | 0.352288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34724628.82 | 0.482625E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.973041E+09 | 0.109533E+10 | 0.218926E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.302600E+10 |
February | 0.882782E+09 | 0.933404E+09 | 0.198154E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.259712E+10 |
March | 0.105485E+10 | 0.107229E+10 | 0.227023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180430E+10 |
April | 0.936002E+09 | 0.933833E+09 | 0.211444E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 63894.63 | 0.164453E+10 |
May | 0.101394E+10 | 0.985396E+09 | 0.222974E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4886281.05 | 0.849044E+09 |
June | 0.101113E+10 | 0.973068E+09 | 0.218691E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22857507.58 | 0.454968E+09 |
July | 0.938820E+09 | 0.915937E+09 | 0.215669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24202683.02 | 0.353276E+09 |
August | 0.105485E+10 | 0.103566E+10 | 0.227023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8853227.49 | 0.473488E+09 |
September | 0.936002E+09 | 0.945520E+09 | 0.211327E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 302355.35 | 0.762673E+09 |
October | 0.973041E+09 | 0.102017E+10 | 0.218984E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.112225E+10 |
November | 0.963541E+09 | 0.106684E+10 | 0.213967E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200964E+10 |
December | 0.938820E+09 | 0.107787E+10 | 0.215610E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.321772E+10 |
Annual Sum or Average | 0.116768E+11 | 0.120553E+11 | 0.259979E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 61165949.11 | 0.183150E+11 |
Minimum of Months | 0.882782E+09 | 0.915937E+09 | 0.198154E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.353276E+09 |
Maximum of Months | 0.105485E+10 | 0.109533E+10 | 0.227023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24202683.02 | 0.321772E+10 |
Report: SpaceGainsMonthly
For: DATACENTER_BOT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.174411E+09 | 0.497722E+09 | 0.521915E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.158233E+09 | 0.451470E+09 | 0.942813E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.189074E+09 | 0.536472E+09 | 0.156645E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.167772E+09 | 0.479179E+09 | 0.201821E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.181743E+09 | 0.517097E+09 | 0.522616E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.181238E+09 | 0.514597E+09 | 0.101086E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.168277E+09 | 0.481680E+09 | 0.156645E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.189074E+09 | 0.536472E+09 | 0.208555E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.167772E+09 | 0.479179E+09 | 0.505780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.174411E+09 | 0.497722E+09 | 0.104453E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.172708E+09 | 0.491888E+09 | 0.151524E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.168277E+09 | 0.481680E+09 | 0.208766E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.209299E+10 | 0.596516E+10 | 0.153881E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.158233E+09 | 0.451470E+09 | 0.505780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.189074E+09 | 0.536472E+09 | 0.208766E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: DATACENTER_MID_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.174411E+09 | 0.497722E+09 | 0.521915E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.158233E+09 | 0.451470E+09 | 0.942813E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.189074E+09 | 0.536472E+09 | 0.156645E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.167772E+09 | 0.479179E+09 | 0.201821E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.181743E+09 | 0.517097E+09 | 0.522616E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.181238E+09 | 0.514597E+09 | 0.101086E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.168277E+09 | 0.481680E+09 | 0.156645E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.189074E+09 | 0.536472E+09 | 0.208555E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.167772E+09 | 0.479179E+09 | 0.505780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.174411E+09 | 0.497722E+09 | 0.104453E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.172708E+09 | 0.491888E+09 | 0.151524E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.168277E+09 | 0.481680E+09 | 0.208766E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.209299E+10 | 0.596516E+10 | 0.153881E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.158233E+09 | 0.451470E+09 | 0.505780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.189074E+09 | 0.536472E+09 | 0.208766E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: DATACENTER_TOP_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.174411E+09 | 0.497722E+09 | 0.521915E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.158233E+09 | 0.451470E+09 | 0.942813E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.189074E+09 | 0.536472E+09 | 0.156645E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.167772E+09 | 0.479179E+09 | 0.201821E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.181743E+09 | 0.517097E+09 | 0.522616E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.181238E+09 | 0.514597E+09 | 0.101086E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.168277E+09 | 0.481680E+09 | 0.156645E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.189074E+09 | 0.536472E+09 | 0.208555E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.167772E+09 | 0.479179E+09 | 0.505780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.174411E+09 | 0.497722E+09 | 0.104453E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.172708E+09 | 0.491888E+09 | 0.151524E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.168277E+09 | 0.481680E+09 | 0.208766E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.209299E+10 | 0.596516E+10 | 0.153881E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.158233E+09 | 0.451470E+09 | 0.505780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.189074E+09 | 0.536472E+09 | 0.208766E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: DATACENTER_BASEMENT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.377547E+10 | 0.565679E+10 | 0.254202E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.342526E+10 | 0.513113E+10 | 0.459203E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.409289E+10 | 0.609720E+10 | 0.762947E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.363176E+10 | 0.544605E+10 | 0.982982E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.393418E+10 | 0.587700E+10 | 0.254544E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.392325E+10 | 0.584858E+10 | 0.492345E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.364269E+10 | 0.547447E+10 | 0.762947E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.409289E+10 | 0.609720E+10 | 0.101578E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.363176E+10 | 0.544605E+10 | 0.246344E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.377547E+10 | 0.565679E+10 | 0.508746E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.373861E+10 | 0.559049E+10 | 0.738006E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.364269E+10 | 0.547447E+10 | 0.101681E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.453069E+11 | 0.677962E+11 | 0.749486E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.342526E+10 | 0.513113E+10 | 0.246344E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.409289E+10 | 0.609720E+10 | 0.101681E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: GROUNDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.346373E+10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.311392E+10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.214754E+10 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 997536.96 | 0.205100E+10 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3955350.32 | 0.949720E+09 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20474991.09 | 0.511236E+09 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23495823.93 | 0.361524E+09 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6119386.16 | 0.521470E+09 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 145687.53 | 0.921756E+09 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144301E+10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.256118E+10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.380582E+10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55188776.00 | 0.218519E+11 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.361524E+09 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23495823.93 | 0.380582E+10 |
Report: SpaceGainsMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.586763E+10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.521410E+10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.365760E+10 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4263669.25 | 0.348423E+10 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7112880.43 | 0.166745E+10 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37622879.96 | 0.894138E+09 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42799073.01 | 0.646691E+09 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11503459.38 | 0.909575E+09 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 244689.98 | 0.160056E+10 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.244132E+10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.427794E+10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.634682E+10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103547E+09 | 0.370081E+11 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.646691E+09 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42799073.01 | 0.634682E+10 |
Report: SpaceGainsMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.649608E+10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.563438E+10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.394791E+10 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2365647.54 | 0.366502E+10 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4933336.02 | 0.186680E+10 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33046768.52 | 0.102308E+10 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32271690.69 | 0.760272E+09 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8369494.54 | 0.105063E+10 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63677.97 | 0.175102E+10 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.251302E+10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.445889E+10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.692466E+10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 81050615.29 | 0.400918E+11 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.760272E+09 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33046768.52 | 0.692466E+10 |
Report: PeakSpaceGainsMonthly
For: BASEMENT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 17832.21 | 02-JAN-10:09 | 20994.62 | 02-JAN-08:09 | 13457.54 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 17832.21 | 01-FEB-10:09 | 20994.62 | 01-FEB-08:09 | 13457.54 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 17832.21 | 01-MAR-10:09 | 20994.62 | 01-MAR-08:09 | 13457.54 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 17832.21 | 03-APR-09:09 | 20994.62 | 03-APR-07:10 | 13457.54 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 17832.21 | 01-MAY-09:09 | 20994.62 | 01-MAY-07:10 | 13457.54 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 17832.21 | 01-JUN-09:09 | 20994.62 | 01-JUN-07:10 | 13457.54 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 17832.21 | 03-JUL-09:09 | 20994.62 | 03-JUL-07:10 | 13457.54 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 17832.21 | 01-AUG-09:09 | 20994.62 | 01-AUG-07:10 | 13457.54 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 17832.21 | 01-SEP-09:09 | 20994.62 | 01-SEP-07:10 | 13457.54 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 17832.21 | 02-OCT-09:09 | 20994.62 | 02-OCT-07:10 | 13457.54 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 17832.21 | 01-NOV-09:09 | 20994.62 | 01-NOV-07:10 | 13457.54 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 17832.21 | 01-DEC-10:09 | 20994.62 | 01-DEC-08:09 | 13457.54 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 17832.21 | 20994.62 | 13457.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 17832.21 | 20994.62 | 13457.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 16014.58 | 02-JAN-10:09 | 18854.65 | 02-JAN-08:09 | 18128.59 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 16014.58 | 01-FEB-10:09 | 18854.65 | 01-FEB-08:09 | 18128.59 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 16014.58 | 01-MAR-10:09 | 18854.65 | 01-MAR-08:09 | 18128.59 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 16014.58 | 03-APR-09:09 | 18854.65 | 03-APR-07:10 | 18128.59 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 16014.58 | 01-MAY-09:09 | 18854.65 | 01-MAY-07:10 | 18128.59 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 16014.58 | 01-JUN-09:09 | 18854.65 | 01-JUN-07:10 | 18128.59 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 16014.58 | 03-JUL-09:09 | 18854.65 | 03-JUL-07:10 | 18128.59 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 16014.58 | 01-AUG-09:09 | 18854.65 | 01-AUG-07:10 | 18128.59 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 16014.58 | 01-SEP-09:09 | 18854.65 | 01-SEP-07:10 | 18128.59 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 16014.58 | 02-OCT-09:09 | 18854.65 | 02-OCT-07:10 | 18128.59 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 16014.58 | 01-NOV-09:09 | 18854.65 | 01-NOV-07:10 | 18128.59 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 16014.58 | 01-DEC-10:09 | 18854.65 | 01-DEC-08:09 | 18128.59 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 16014.58 | 18854.65 | 18128.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 16014.58 | 18854.65 | 18128.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: CORE_MID
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 16014.58 | 02-JAN-10:09 | 18854.65 | 02-JAN-08:09 | 18128.52 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 16014.58 | 01-FEB-10:09 | 18854.65 | 01-FEB-08:09 | 18128.52 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 16014.58 | 01-MAR-10:09 | 18854.65 | 01-MAR-08:09 | 18128.52 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 16014.58 | 03-APR-09:09 | 18854.65 | 03-APR-07:10 | 18128.52 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 16014.58 | 01-MAY-09:09 | 18854.65 | 01-MAY-07:10 | 18128.52 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 16014.58 | 01-JUN-09:09 | 18854.65 | 01-JUN-07:10 | 18128.52 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 16014.58 | 03-JUL-09:09 | 18854.65 | 03-JUL-07:10 | 18128.52 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 16014.58 | 01-AUG-09:09 | 18854.65 | 01-AUG-07:10 | 18128.52 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 16014.58 | 01-SEP-09:09 | 18854.65 | 01-SEP-07:10 | 18128.52 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 16014.58 | 02-OCT-09:09 | 18854.65 | 02-OCT-07:10 | 18128.52 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 16014.58 | 01-NOV-09:09 | 18854.65 | 01-NOV-07:10 | 18128.52 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 16014.58 | 01-DEC-10:09 | 18854.65 | 01-DEC-08:09 | 18128.52 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 16014.58 | 18854.65 | 18128.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 16014.58 | 18854.65 | 18128.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: CORE_TOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 16014.58 | 02-JAN-10:09 | 18854.65 | 02-JAN-08:09 | 18128.52 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 16014.58 | 01-FEB-10:09 | 18854.65 | 01-FEB-08:09 | 18128.52 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 16014.58 | 01-MAR-10:09 | 18854.65 | 01-MAR-08:09 | 18128.52 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 16014.58 | 03-APR-09:09 | 18854.65 | 03-APR-07:10 | 18128.52 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 16014.58 | 01-MAY-09:09 | 18854.65 | 01-MAY-07:10 | 18128.52 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 16014.58 | 01-JUN-09:09 | 18854.65 | 01-JUN-07:10 | 18128.52 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 16014.58 | 03-JUL-09:09 | 18854.65 | 03-JUL-07:10 | 18128.52 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 16014.58 | 01-AUG-09:09 | 18854.65 | 01-AUG-07:10 | 18128.52 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 16014.58 | 01-SEP-09:09 | 18854.65 | 01-SEP-07:10 | 18128.52 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 16014.58 | 02-OCT-09:09 | 18854.65 | 02-OCT-07:10 | 18128.52 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 16014.58 | 01-NOV-09:09 | 18854.65 | 01-NOV-07:10 | 18128.52 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 16014.58 | 01-DEC-10:09 | 18854.65 | 01-DEC-08:09 | 18128.52 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 16014.58 | 18854.65 | 18128.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 16014.58 | 18854.65 | 18128.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2010.79 | 02-JAN-10:09 | 2367.39 | 02-JAN-08:09 | 2276.32 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 2909.66 | 04-JAN-05:52 |
February | 2010.79 | 01-FEB-10:09 | 2108.91 | 01-FEB-16:00 | 2276.32 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 3635.73 | 12-FEB-22:53 |
March | 2010.79 | 01-MAR-10:09 | 1954.24 | 03-MAR-16:00 | 2276.32 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1786.11 | 15-MAR-05:00 |
April | 2010.79 | 03-APR-09:09 | 1454.29 | 03-APR-07:10 | 2276.32 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 146.77 | 23-APR-16:10 | 1571.54 | 01-APR-19:00 |
May | 2010.79 | 01-MAY-09:09 | 1454.29 | 01-MAY-07:10 | 2276.32 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.46 | 24-MAY-15:00 | 787.27 | 08-MAY-24:00 |
June | 2010.79 | 01-JUN-09:09 | 1454.29 | 01-JUN-07:10 | 2276.32 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 135.68 | 24-JUN-17:02 | 541.06 | 10-JUN-22:00 |
July | 2010.79 | 03-JUL-09:09 | 1454.29 | 03-JUL-07:10 | 2276.32 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 213.06 | 23-JUL-15:00 | 490.33 | 09-JUL-09:42 |
August | 2010.79 | 01-AUG-09:09 | 1769.31 | 31-AUG-07:10 | 2276.32 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 80.02 | 08-AUG-16:00 | 716.93 | 27-AUG-06:00 |
September | 2010.79 | 01-SEP-09:09 | 1804.02 | 19-SEP-07:10 | 2276.32 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.80 | 01-SEP-15:00 | 940.48 | 20-SEP-01:00 |
October | 2010.79 | 02-OCT-09:09 | 2342.45 | 31-OCT-07:10 | 2276.32 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 1194.34 | 31-OCT-21:10 |
November | 2010.79 | 01-NOV-09:09 | 2367.39 | 06-NOV-16:49 | 2276.32 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 2230.77 | 22-NOV-02:00 |
December | 2010.79 | 01-DEC-10:09 | 2367.39 | 01-DEC-16:19 | 2276.32 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2896.49 | 16-DEC-05:52 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 2010.79 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 490.33 | |||||
Maximum of Months | 2010.79 | 2367.39 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 213.06 | 3635.73 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1295.83 | 02-JAN-10:09 | 1525.64 | 02-JAN-08:09 | 1466.95 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 1939.00 | 04-JAN-05:52 |
February | 1295.83 | 01-FEB-10:09 | 1382.36 | 02-FEB-16:00 | 1466.95 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 2397.31 | 12-FEB-22:53 |
March | 1295.83 | 01-MAR-10:09 | 1277.67 | 03-MAR-16:00 | 1466.95 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1190.75 | 15-MAR-04:57 |
April | 1295.83 | 03-APR-09:09 | 937.20 | 03-APR-07:10 | 1466.95 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 166.31 | 23-APR-16:10 | 1012.44 | 01-APR-19:00 |
May | 1295.83 | 01-MAY-09:09 | 937.20 | 01-MAY-07:10 | 1466.95 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.31 | 24-MAY-15:00 | 532.22 | 14-MAY-08:10 |
June | 1295.83 | 01-JUN-09:09 | 937.20 | 01-JUN-07:10 | 1466.95 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 118.75 | 24-JUN-17:02 | 335.70 | 10-JUN-22:00 |
July | 1295.83 | 03-JUL-09:09 | 937.20 | 03-JUL-07:10 | 1466.95 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 184.88 | 23-JUL-15:00 | 320.49 | 09-JUL-08:00 |
August | 1295.83 | 01-AUG-09:09 | 1087.18 | 31-AUG-07:10 | 1466.95 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.35 | 08-AUG-16:00 | 456.86 | 27-AUG-06:00 |
September | 1295.83 | 01-SEP-09:09 | 1085.97 | 19-SEP-07:10 | 1466.95 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.54 | 01-SEP-15:00 | 610.36 | 20-SEP-01:00 |
October | 1295.83 | 02-OCT-09:09 | 1504.78 | 31-OCT-07:10 | 1466.95 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 774.60 | 31-OCT-21:10 |
November | 1295.83 | 01-NOV-09:09 | 1525.64 | 06-NOV-16:49 | 1466.95 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1436.06 | 22-NOV-02:00 |
December | 1295.83 | 01-DEC-10:09 | 1525.64 | 01-DEC-16:19 | 1466.95 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1931.00 | 16-DEC-05:52 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1295.83 | 937.20 | 1466.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 320.49 | |||||
Maximum of Months | 1295.83 | 1525.64 | 1466.95 | 0.00 | 0.00 | 0.00 | 0.00 | 184.88 | 2397.31 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2010.83 | 02-JAN-10:09 | 2367.44 | 02-JAN-08:09 | 2276.35 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 2908.09 | 04-JAN-05:52 |
February | 2010.83 | 01-FEB-10:09 | 2029.67 | 02-FEB-16:00 | 2276.35 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 3519.87 | 12-FEB-22:53 |
March | 2010.83 | 01-MAR-10:09 | 1920.80 | 03-MAR-16:00 | 2276.35 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1786.11 | 15-MAR-05:00 |
April | 2010.83 | 03-APR-09:09 | 1454.32 | 03-APR-07:10 | 2276.35 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 62.67 | 23-APR-16:10 | 1609.67 | 16-APR-11:52 |
May | 2010.83 | 01-MAY-09:09 | 1454.32 | 01-MAY-07:10 | 2276.35 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.46 | 24-MAY-15:00 | 770.67 | 08-MAY-24:00 |
June | 2010.83 | 01-JUN-09:09 | 1454.32 | 01-JUN-07:10 | 2276.35 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 151.71 | 24-JUN-17:02 | 512.11 | 20-JUN-03:50 |
July | 2010.83 | 03-JUL-09:09 | 1454.32 | 03-JUL-07:10 | 2276.35 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 221.51 | 23-JUL-14:56 | 454.94 | 09-JUL-08:00 |
August | 2010.83 | 01-AUG-09:09 | 1750.96 | 31-AUG-07:10 | 2276.35 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 80.02 | 08-AUG-16:00 | 723.40 | 27-AUG-06:00 |
September | 2010.83 | 01-SEP-09:09 | 1777.97 | 19-SEP-07:10 | 2276.35 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.74 | 01-SEP-15:00 | 919.33 | 20-SEP-01:00 |
October | 2010.83 | 02-OCT-09:09 | 2336.74 | 31-OCT-07:10 | 2276.35 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 1161.20 | 31-OCT-21:10 |
November | 2010.83 | 01-NOV-09:09 | 2367.44 | 06-NOV-16:49 | 2276.35 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 2135.82 | 22-NOV-02:00 |
December | 2010.83 | 01-DEC-10:09 | 2367.44 | 01-DEC-16:19 | 2276.35 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2896.48 | 16-DEC-05:55 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 2010.83 | 1454.32 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 454.94 | |||||
Maximum of Months | 2010.83 | 2367.44 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 221.51 | 3519.87 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1295.83 | 02-JAN-10:09 | 1525.64 | 02-JAN-08:09 | 1466.94 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 1943.68 | 04-JAN-05:52 |
February | 1295.83 | 01-FEB-10:09 | 1273.71 | 01-FEB-08:09 | 1466.94 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 2529.26 | 12-FEB-22:53 |
March | 1295.83 | 01-MAR-10:09 | 1284.81 | 13-MAR-07:10 | 1466.94 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1235.93 | 17-MAR-03:55 |
April | 1295.83 | 03-APR-09:09 | 1040.51 | 03-APR-07:10 | 1466.94 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 1143.29 | 09-APR-13:00 |
May | 1295.83 | 01-MAY-09:09 | 937.20 | 01-MAY-07:10 | 1466.94 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.31 | 24-MAY-15:00 | 543.25 | 08-MAY-24:00 |
June | 1295.83 | 01-JUN-09:09 | 937.20 | 01-JUN-07:10 | 1466.94 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 80.74 | 29-JUN-16:00 | 406.54 | 10-JUN-22:00 |
July | 1295.83 | 03-JUL-09:09 | 937.20 | 03-JUL-07:10 | 1466.94 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 140.67 | 23-JUL-14:56 | 372.20 | 09-JUL-08:00 |
August | 1295.83 | 01-AUG-09:09 | 1164.31 | 31-AUG-07:10 | 1466.94 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.35 | 08-AUG-16:00 | 563.54 | 27-AUG-06:00 |
September | 1295.83 | 01-SEP-09:09 | 1196.72 | 19-SEP-07:10 | 1466.94 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.54 | 01-SEP-15:00 | 652.32 | 20-SEP-01:00 |
October | 1295.83 | 02-OCT-09:09 | 1510.24 | 31-OCT-07:10 | 1466.94 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 812.91 | 31-OCT-21:10 |
November | 1295.83 | 01-NOV-09:09 | 1525.64 | 06-NOV-16:49 | 1466.94 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1576.75 | 22-NOV-02:00 |
December | 1295.83 | 01-DEC-10:09 | 1525.64 | 01-DEC-16:19 | 1466.94 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1934.30 | 16-DEC-05:51 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1295.83 | 937.20 | 1466.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 372.20 | |||||
Maximum of Months | 1295.83 | 1525.64 | 1466.94 | 0.00 | 0.00 | 0.00 | 0.00 | 140.67 | 2529.26 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2010.79 | 02-JAN-10:09 | 2367.39 | 02-JAN-08:09 | 2276.32 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 6456.98 | 04-JAN-06:00 |
February | 2010.79 | 01-FEB-10:09 | 2118.34 | 01-FEB-16:00 | 2276.32 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 7840.49 | 12-FEB-22:57 |
March | 2010.79 | 01-MAR-10:09 | 1966.48 | 03-MAR-16:00 | 2276.32 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 4116.05 | 15-MAR-04:52 |
April | 2010.79 | 03-APR-09:09 | 1454.29 | 03-APR-07:10 | 2276.32 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 502.13 | 23-APR-15:51 | 3188.08 | 01-APR-19:00 |
May | 2010.79 | 01-MAY-09:09 | 1454.29 | 01-MAY-07:10 | 2276.32 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.06 | 24-MAY-15:00 | 1704.93 | 29-MAY-18:00 |
June | 2010.79 | 01-JUN-09:09 | 1454.29 | 01-JUN-07:10 | 2276.32 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 324.78 | 24-JUN-17:02 | 1177.95 | 20-JUN-03:53 |
July | 2010.79 | 03-JUL-09:09 | 1454.29 | 03-JUL-07:10 | 2276.32 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 494.08 | 23-JUL-15:00 | 1137.80 | 06-JUL-21:53 |
August | 2010.79 | 01-AUG-09:09 | 1786.98 | 31-AUG-07:10 | 2276.32 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 184.57 | 08-AUG-16:00 | 1539.08 | 27-AUG-06:00 |
September | 2010.79 | 01-SEP-09:09 | 1820.60 | 19-SEP-07:10 | 2276.32 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.47 | 01-SEP-15:00 | 1996.22 | 20-SEP-01:00 |
October | 2010.79 | 02-OCT-09:09 | 2343.17 | 31-OCT-07:10 | 2276.32 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 2675.47 | 31-OCT-21:03 |
November | 2010.79 | 01-NOV-09:09 | 2367.39 | 06-NOV-16:49 | 2276.32 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 4385.89 | 22-NOV-02:00 |
December | 2010.79 | 01-DEC-10:09 | 2367.39 | 01-DEC-16:19 | 2276.32 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 6483.86 | 16-DEC-05:51 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 2010.79 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1137.80 | |||||
Maximum of Months | 2010.79 | 2367.39 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 502.13 | 7840.49 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1239.33 | 02-JAN-08:09 | 1525.64 | 02-JAN-08:09 | 1466.95 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 4594.96 | 04-JAN-06:00 |
February | 1239.33 | 01-FEB-08:09 | 1383.59 | 02-FEB-16:00 | 1466.95 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 5226.91 | 12-FEB-22:55 |
March | 1239.33 | 01-MAR-08:09 | 1279.56 | 03-MAR-16:00 | 1466.95 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 2768.52 | 15-MAR-04:52 |
April | 1239.33 | 03-APR-07:10 | 937.20 | 03-APR-07:10 | 1466.95 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 445.40 | 23-APR-16:10 | 2251.89 | 16-APR-11:52 |
May | 1239.33 | 01-MAY-07:10 | 937.20 | 01-MAY-07:10 | 1466.95 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.38 | 24-MAY-15:00 | 1200.90 | 14-MAY-08:10 |
June | 1239.33 | 01-JUN-07:10 | 937.20 | 01-JUN-07:10 | 1466.95 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 284.25 | 24-JUN-17:02 | 764.12 | 20-JUN-03:53 |
July | 1239.33 | 03-JUL-07:10 | 937.20 | 03-JUL-07:10 | 1466.95 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 385.50 | 23-JUL-15:00 | 732.49 | 06-JUL-22:00 |
August | 1239.33 | 01-AUG-07:10 | 1092.37 | 31-AUG-07:10 | 1466.95 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 123.05 | 08-AUG-16:00 | 1045.22 | 27-AUG-06:00 |
September | 1239.33 | 01-SEP-07:10 | 1091.88 | 19-SEP-07:10 | 1466.95 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.98 | 01-SEP-15:00 | 1285.31 | 20-SEP-01:00 |
October | 1239.33 | 02-OCT-07:10 | 1505.07 | 31-OCT-07:10 | 1466.95 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 1782.57 | 31-OCT-21:03 |
November | 1239.33 | 01-NOV-07:10 | 1525.64 | 06-NOV-16:49 | 1466.95 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 2888.39 | 22-NOV-02:00 |
December | 1239.33 | 01-DEC-08:09 | 1525.64 | 01-DEC-16:19 | 1466.95 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 4477.37 | 16-DEC-05:51 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1239.33 | 937.20 | 1466.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 732.49 | |||||
Maximum of Months | 1239.33 | 1525.64 | 1466.95 | 0.00 | 0.00 | 0.00 | 0.00 | 445.40 | 5226.91 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2010.83 | 02-JAN-10:09 | 2367.44 | 02-JAN-08:09 | 2276.35 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 6891.93 | 04-JAN-06:00 |
February | 2010.83 | 01-FEB-10:09 | 2041.32 | 02-FEB-16:00 | 2276.35 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 7840.52 | 12-FEB-22:55 |
March | 2010.83 | 01-MAR-10:09 | 1934.51 | 03-MAR-16:00 | 2276.35 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 4161.72 | 15-MAR-04:52 |
April | 2010.83 | 03-APR-09:09 | 1454.32 | 03-APR-07:10 | 2276.35 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.52 | 23-APR-16:04 | 3629.04 | 16-APR-12:00 |
May | 2010.83 | 01-MAY-09:09 | 1454.32 | 01-MAY-07:10 | 2276.35 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.06 | 24-MAY-15:00 | 1735.15 | 29-MAY-18:00 |
June | 2010.83 | 01-JUN-09:09 | 1454.32 | 01-JUN-07:10 | 2276.35 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 357.11 | 24-JUN-17:02 | 1164.91 | 20-JUN-03:53 |
July | 2010.83 | 03-JUL-09:09 | 1454.32 | 03-JUL-07:10 | 2276.35 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 495.32 | 23-JUL-14:56 | 1150.14 | 06-JUL-22:00 |
August | 2010.83 | 01-AUG-09:09 | 1769.36 | 31-AUG-07:10 | 2276.35 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 184.57 | 08-AUG-16:00 | 1609.16 | 27-AUG-06:00 |
September | 2010.83 | 01-SEP-09:09 | 1795.57 | 19-SEP-07:10 | 2276.35 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.32 | 01-SEP-15:00 | 1975.62 | 20-SEP-01:00 |
October | 2010.83 | 02-OCT-09:09 | 2337.74 | 31-OCT-07:10 | 2276.35 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 2677.72 | 31-OCT-21:03 |
November | 2010.83 | 01-NOV-09:09 | 2367.44 | 06-NOV-16:49 | 2276.35 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 4375.67 | 22-NOV-02:00 |
December | 2010.83 | 01-DEC-10:09 | 2367.44 | 01-DEC-16:19 | 2276.35 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 6722.98 | 16-DEC-05:51 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 2010.83 | 1454.32 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1150.14 | |||||
Maximum of Months | 2010.83 | 2367.44 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 495.32 | 7840.52 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1295.83 | 02-JAN-10:09 | 1525.64 | 02-JAN-08:09 | 1466.94 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 4595.04 | 04-JAN-05:57 |
February | 1295.83 | 01-FEB-10:09 | 1277.22 | 02-FEB-16:00 | 1466.94 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 5227.08 | 12-FEB-22:55 |
March | 1295.83 | 01-MAR-10:09 | 1286.66 | 13-MAR-07:10 | 1466.94 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 2772.25 | 15-MAR-04:52 |
April | 1295.83 | 03-APR-09:09 | 1044.15 | 03-APR-07:10 | 1466.94 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.53 | 23-APR-13:30 | 2182.45 | 01-APR-19:00 |
May | 1295.83 | 01-MAY-09:09 | 937.20 | 01-MAY-07:10 | 1466.94 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.38 | 24-MAY-15:00 | 1168.46 | 29-MAY-18:00 |
June | 1295.83 | 01-JUN-09:09 | 937.20 | 01-JUN-07:10 | 1466.94 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 232.25 | 18-JUN-12:10 | 792.94 | 20-JUN-03:53 |
July | 1295.83 | 03-JUL-09:09 | 937.20 | 03-JUL-07:10 | 1466.94 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 326.25 | 23-JUL-14:56 | 892.44 | 06-JUL-22:00 |
August | 1295.83 | 01-AUG-09:09 | 1167.02 | 31-AUG-07:10 | 1466.94 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 129.88 | 20-AUG-12:50 | 1116.39 | 27-AUG-06:00 |
September | 1295.83 | 01-SEP-09:09 | 1199.20 | 19-SEP-07:10 | 1466.94 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.98 | 01-SEP-15:00 | 1304.67 | 20-SEP-01:00 |
October | 1295.83 | 02-OCT-09:09 | 1510.37 | 31-OCT-07:10 | 1466.94 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 1785.29 | 31-OCT-21:03 |
November | 1295.83 | 01-NOV-09:09 | 1525.64 | 06-NOV-16:49 | 1466.94 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 2935.52 | 22-NOV-02:00 |
December | 1295.83 | 01-DEC-10:09 | 1525.64 | 01-DEC-16:19 | 1466.94 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 4483.70 | 16-DEC-05:51 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1295.83 | 937.20 | 1466.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 792.94 | |||||
Maximum of Months | 1295.83 | 1525.64 | 1466.94 | 0.00 | 0.00 | 0.00 | 0.00 | 326.25 | 5227.08 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2010.79 | 02-JAN-10:09 | 2367.39 | 02-JAN-08:09 | 2276.32 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 7899.16 | 04-JAN-06:00 |
February | 2010.79 | 01-FEB-10:09 | 2118.61 | 01-FEB-16:00 | 2276.32 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 9757.98 | 12-FEB-23:00 |
March | 2010.79 | 01-MAR-10:09 | 1966.10 | 03-MAR-16:00 | 2276.32 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 5032.46 | 15-MAR-05:00 |
April | 2010.79 | 03-APR-09:09 | 1454.29 | 03-APR-07:10 | 2276.32 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 782.21 | 23-APR-16:00 | 3624.24 | 01-APR-18:00 |
May | 2010.79 | 01-MAY-09:09 | 1454.29 | 01-MAY-07:10 | 2276.32 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 100.08 | 24-MAY-15:00 | 2056.29 | 29-MAY-18:00 |
June | 2010.79 | 01-JUN-09:09 | 1454.29 | 01-JUN-07:10 | 2276.32 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 405.53 | 24-JUN-17:02 | 1387.85 | 20-JUN-03:53 |
July | 2010.79 | 03-JUL-09:09 | 1454.29 | 03-JUL-07:10 | 2276.32 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 641.12 | 23-JUL-15:00 | 1387.86 | 06-JUL-21:53 |
August | 2010.79 | 01-AUG-09:09 | 1786.40 | 31-AUG-07:10 | 2276.32 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 233.11 | 20-AUG-13:12 | 1832.84 | 27-AUG-06:00 |
September | 2010.79 | 01-SEP-09:09 | 1820.09 | 19-SEP-07:10 | 2276.32 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.42 | 01-SEP-15:00 | 2281.46 | 20-SEP-01:00 |
October | 2010.79 | 02-OCT-09:09 | 2343.14 | 31-OCT-07:10 | 2276.32 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3311.90 | 31-OCT-21:03 |
November | 2010.79 | 01-NOV-09:09 | 2367.39 | 06-NOV-16:49 | 2276.32 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 5182.87 | 21-NOV-22:02 |
December | 2010.79 | 01-DEC-10:09 | 2367.39 | 01-DEC-16:19 | 2276.32 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 7954.34 | 16-DEC-06:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 2010.79 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1387.85 | |||||
Maximum of Months | 2010.79 | 2367.39 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 782.21 | 9757.98 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1295.83 | 02-JAN-10:09 | 1525.64 | 02-JAN-08:09 | 1466.95 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 5637.49 | 04-JAN-06:00 |
February | 1295.83 | 01-FEB-10:09 | 1383.49 | 02-FEB-16:00 | 1466.95 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 6511.49 | 12-FEB-22:57 |
March | 1295.83 | 01-MAR-10:09 | 1279.33 | 03-MAR-16:00 | 1466.95 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 3485.53 | 15-MAR-04:55 |
April | 1295.83 | 03-APR-09:09 | 937.20 | 03-APR-07:10 | 1466.95 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 611.34 | 23-APR-16:00 | 2415.94 | 01-APR-18:00 |
May | 1295.83 | 01-MAY-09:09 | 937.20 | 01-MAY-07:10 | 1466.95 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 66.72 | 24-MAY-15:00 | 1396.65 | 14-MAY-08:30 |
June | 1295.83 | 01-JUN-09:09 | 937.20 | 01-JUN-07:10 | 1466.95 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 329.26 | 24-JUN-17:02 | 901.78 | 20-JUN-03:53 |
July | 1295.83 | 03-JUL-09:09 | 937.20 | 03-JUL-07:10 | 1466.95 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 459.52 | 23-JUL-15:00 | 904.45 | 06-JUL-22:00 |
August | 1295.83 | 01-AUG-09:09 | 1092.08 | 31-AUG-07:10 | 1466.95 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 150.21 | 08-AUG-16:00 | 1252.88 | 27-AUG-06:00 |
September | 1295.83 | 01-SEP-09:09 | 1091.65 | 19-SEP-07:10 | 1466.95 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22.28 | 01-SEP-15:00 | 1485.34 | 20-SEP-01:00 |
October | 1295.83 | 02-OCT-09:09 | 1505.06 | 31-OCT-07:10 | 1466.95 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 2207.68 | 31-OCT-21:03 |
November | 1295.83 | 01-NOV-09:09 | 1525.64 | 06-NOV-16:49 | 1466.95 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 3452.91 | 21-NOV-22:02 |
December | 1295.83 | 01-DEC-10:09 | 1525.64 | 01-DEC-16:19 | 1466.95 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 5657.76 | 16-DEC-06:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1295.83 | 937.20 | 1466.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 901.78 | |||||
Maximum of Months | 1295.83 | 1525.64 | 1466.95 | 0.00 | 0.00 | 0.00 | 0.00 | 611.34 | 6511.49 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2010.83 | 02-JAN-10:09 | 2367.44 | 02-JAN-08:09 | 2276.35 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 8316.16 | 04-JAN-06:00 |
February | 2010.83 | 01-FEB-10:09 | 2041.21 | 02-FEB-16:00 | 2276.35 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 9767.12 | 12-FEB-22:57 |
March | 2010.83 | 01-MAR-10:09 | 1934.14 | 03-MAR-16:00 | 2276.35 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 5228.43 | 15-MAR-04:57 |
April | 2010.83 | 03-APR-09:09 | 1454.32 | 03-APR-07:10 | 2276.35 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 145.88 | 23-APR-18:00 | 3758.29 | 16-APR-12:00 |
May | 2010.83 | 01-MAY-09:09 | 1454.32 | 01-MAY-07:10 | 2276.35 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 100.08 | 24-MAY-15:00 | 2097.28 | 29-MAY-18:00 |
June | 2010.83 | 01-JUN-09:09 | 1454.32 | 01-JUN-07:10 | 2276.35 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 420.49 | 24-JUN-17:02 | 1371.82 | 20-JUN-03:53 |
July | 2010.83 | 03-JUL-09:09 | 1454.32 | 03-JUL-07:10 | 2276.35 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 635.15 | 23-JUL-14:56 | 1408.25 | 06-JUL-22:00 |
August | 2010.83 | 01-AUG-09:09 | 1768.79 | 31-AUG-07:10 | 2276.35 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 225.31 | 08-AUG-16:00 | 1933.22 | 27-AUG-06:00 |
September | 2010.83 | 01-SEP-09:09 | 1795.08 | 19-SEP-07:10 | 2276.35 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.23 | 01-SEP-15:00 | 2270.71 | 20-SEP-01:00 |
October | 2010.83 | 02-OCT-09:09 | 2337.72 | 31-OCT-07:10 | 2276.35 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3315.52 | 31-OCT-21:03 |
November | 2010.83 | 01-NOV-09:09 | 2367.44 | 06-NOV-16:49 | 2276.35 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 5184.01 | 21-NOV-22:02 |
December | 2010.83 | 01-DEC-10:09 | 2367.44 | 01-DEC-16:19 | 2276.35 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 8426.71 | 16-DEC-06:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 2010.83 | 1454.32 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1371.82 | |||||
Maximum of Months | 2010.83 | 2367.44 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 635.15 | 9767.12 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1295.83 | 02-JAN-10:09 | 1525.64 | 02-JAN-08:09 | 1466.94 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 5718.10 | 04-JAN-06:00 |
February | 1295.83 | 01-FEB-10:09 | 1277.22 | 02-FEB-16:00 | 1466.94 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 6511.47 | 12-FEB-23:00 |
March | 1295.83 | 01-MAR-10:09 | 1286.45 | 13-MAR-07:10 | 1466.94 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 3485.64 | 15-MAR-04:55 |
April | 1295.83 | 03-APR-09:09 | 1043.73 | 03-APR-07:10 | 1466.94 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 70.86 | 23-APR-13:20 | 2519.90 | 01-APR-19:00 |
May | 1295.83 | 01-MAY-09:09 | 937.20 | 01-MAY-07:10 | 1466.94 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 66.72 | 24-MAY-15:00 | 1410.33 | 29-MAY-18:00 |
June | 1295.83 | 01-JUN-09:09 | 937.20 | 01-JUN-07:10 | 1466.94 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 277.96 | 18-JUN-12:00 | 935.61 | 20-JUN-03:53 |
July | 1295.83 | 03-JUL-09:09 | 937.20 | 03-JUL-07:10 | 1466.94 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 413.83 | 23-JUL-14:56 | 1099.42 | 06-JUL-21:57 |
August | 1295.83 | 01-AUG-09:09 | 1166.66 | 31-AUG-07:10 | 1466.94 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 168.31 | 20-AUG-13:10 | 1340.61 | 27-AUG-06:00 |
September | 1295.83 | 01-SEP-09:09 | 1198.89 | 19-SEP-07:10 | 1466.94 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22.28 | 01-SEP-15:00 | 1510.24 | 20-SEP-01:00 |
October | 1295.83 | 02-OCT-09:09 | 1510.36 | 31-OCT-07:10 | 1466.94 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 2212.21 | 31-OCT-21:03 |
November | 1295.83 | 01-NOV-09:09 | 1525.64 | 06-NOV-16:49 | 1466.94 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 3458.97 | 21-NOV-22:02 |
December | 1295.83 | 01-DEC-10:09 | 1525.64 | 01-DEC-16:19 | 1466.94 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 5657.76 | 16-DEC-05:59 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1295.83 | 937.20 | 1466.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 935.61 | |||||
Maximum of Months | 1295.83 | 1525.64 | 1466.94 | 0.00 | 0.00 | 0.00 | 0.00 | 413.83 | 6511.47 |
Report: PeakSpaceGainsMonthly
For: DATACENTER_BOT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 232.27 | 02-JAN-10:09 | 520.85 | 02-JAN-08:09 | 1948.61 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 232.27 | 01-FEB-10:09 | 520.85 | 01-FEB-08:09 | 3897.21 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 232.27 | 01-MAR-10:09 | 520.85 | 01-MAR-08:09 | 7794.42 | 31-MAR-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 232.27 | 03-APR-09:09 | 520.85 | 03-APR-07:10 | 7794.42 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 232.27 | 01-MAY-09:09 | 520.85 | 01-MAY-07:10 | 3897.21 | 31-MAY-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 232.27 | 01-JUN-09:09 | 520.85 | 01-JUN-07:10 | 5845.82 | 30-JUN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 232.27 | 03-JUL-09:09 | 520.85 | 03-JUL-07:10 | 7794.42 | 31-JUL-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 232.27 | 01-AUG-09:09 | 520.85 | 01-AUG-07:10 | 7794.42 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 232.27 | 01-SEP-09:09 | 520.85 | 01-SEP-07:10 | 3897.21 | 30-SEP-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 232.27 | 02-OCT-09:09 | 520.85 | 02-OCT-07:10 | 5845.82 | 31-OCT-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 232.27 | 01-NOV-09:09 | 520.85 | 01-NOV-07:10 | 5845.82 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 232.27 | 01-DEC-10:09 | 520.85 | 01-DEC-08:09 | 7794.42 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 232.27 | 520.85 | 1948.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 232.27 | 520.85 | 7794.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: DATACENTER_MID_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 232.27 | 02-JAN-10:09 | 520.85 | 02-JAN-08:09 | 1948.61 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 232.27 | 01-FEB-10:09 | 520.85 | 01-FEB-08:09 | 3897.21 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 232.27 | 01-MAR-10:09 | 520.85 | 01-MAR-08:09 | 7794.42 | 31-MAR-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 232.27 | 03-APR-09:09 | 520.85 | 03-APR-07:10 | 7794.42 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 232.27 | 01-MAY-09:09 | 520.85 | 01-MAY-07:10 | 3897.21 | 31-MAY-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 232.27 | 01-JUN-09:09 | 520.85 | 01-JUN-07:10 | 5845.82 | 30-JUN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 232.27 | 03-JUL-09:09 | 520.85 | 03-JUL-07:10 | 7794.42 | 31-JUL-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 232.27 | 01-AUG-09:09 | 520.85 | 01-AUG-07:10 | 7794.42 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 232.27 | 01-SEP-09:09 | 520.85 | 01-SEP-07:10 | 3897.21 | 30-SEP-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 232.27 | 02-OCT-09:09 | 520.85 | 02-OCT-07:10 | 5845.82 | 31-OCT-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 232.27 | 01-NOV-09:09 | 520.85 | 01-NOV-07:10 | 5845.82 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 232.27 | 01-DEC-10:09 | 520.85 | 01-DEC-08:09 | 7794.42 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 232.27 | 520.85 | 1948.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 232.27 | 520.85 | 7794.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: DATACENTER_TOP_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 232.27 | 02-JAN-10:09 | 520.85 | 02-JAN-08:09 | 1948.61 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 232.27 | 01-FEB-10:09 | 520.85 | 01-FEB-08:09 | 3897.21 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 232.27 | 01-MAR-10:09 | 520.85 | 01-MAR-08:09 | 7794.42 | 31-MAR-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 232.27 | 03-APR-09:09 | 520.85 | 03-APR-07:10 | 7794.42 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 232.27 | 01-MAY-09:09 | 520.85 | 01-MAY-07:10 | 3897.21 | 31-MAY-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 232.27 | 01-JUN-09:09 | 520.85 | 01-JUN-07:10 | 5845.82 | 30-JUN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 232.27 | 03-JUL-09:09 | 520.85 | 03-JUL-07:10 | 7794.42 | 31-JUL-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 232.27 | 01-AUG-09:09 | 520.85 | 01-AUG-07:10 | 7794.42 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 232.27 | 01-SEP-09:09 | 520.85 | 01-SEP-07:10 | 3897.21 | 30-SEP-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 232.27 | 02-OCT-09:09 | 520.85 | 02-OCT-07:10 | 5845.82 | 31-OCT-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 232.27 | 01-NOV-09:09 | 520.85 | 01-NOV-07:10 | 5845.82 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 232.27 | 01-DEC-10:09 | 520.85 | 01-DEC-08:09 | 7794.42 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 232.27 | 520.85 | 1948.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 232.27 | 520.85 | 7794.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: DATACENTER_BASEMENT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 5027.92 | 02-JAN-10:09 | 5919.59 | 02-JAN-08:09 | 94908.13 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 5027.92 | 01-FEB-10:09 | 5919.59 | 01-FEB-08:09 | 189816.26 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 5027.92 | 01-MAR-10:09 | 5919.59 | 01-MAR-08:09 | 379632.52 | 31-MAR-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 5027.92 | 03-APR-09:09 | 5919.59 | 03-APR-07:10 | 379632.52 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 5027.92 | 01-MAY-09:09 | 5919.59 | 01-MAY-07:10 | 189816.26 | 31-MAY-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 5027.92 | 01-JUN-09:09 | 5919.59 | 01-JUN-07:10 | 284724.39 | 30-JUN-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 5027.92 | 03-JUL-09:09 | 5919.59 | 03-JUL-07:10 | 379632.52 | 31-JUL-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 5027.92 | 01-AUG-09:09 | 5919.59 | 01-AUG-07:10 | 379632.52 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 5027.92 | 01-SEP-09:09 | 5919.59 | 01-SEP-07:10 | 189816.26 | 30-SEP-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 5027.92 | 02-OCT-09:09 | 5919.59 | 02-OCT-07:10 | 284724.39 | 31-OCT-23:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 5027.92 | 01-NOV-09:09 | 5919.59 | 01-NOV-07:10 | 284724.39 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 5027.92 | 01-DEC-10:09 | 5919.59 | 01-DEC-08:09 | 379632.52 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 5027.92 | 5919.59 | 94908.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 5027.92 | 5919.59 | 379632.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: GROUNDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 5841.59 | 04-JAN-05:52 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 7816.06 | 12-FEB-22:53 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 3756.54 | 15-MAR-04:52 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 189.65 | 23-APR-15:51 | 3314.27 | 01-APR-19:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.24 | 24-MAY-15:00 | 1641.09 | 09-MAY-01:00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 283.30 | 24-JUN-17:02 | 1101.49 | 20-JUN-03:55 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 439.87 | 23-JUL-15:00 | 1016.25 | 06-JUL-21:53 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 141.76 | 08-AUG-16:00 | 1463.10 | 27-AUG-06:00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.87 | 01-SEP-15:00 | 1958.39 | 20-SEP-01:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 2506.54 | 31-OCT-21:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 4724.65 | 22-NOV-02:00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 6054.06 | 16-DEC-05:51 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1016.25 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 439.87 | 7816.06 |
Report: PeakSpaceGainsMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 10098.65 | 04-JAN-06:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 12983.42 | 12-FEB-22:53 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 6490.04 | 15-MAR-04:52 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 540.88 | 23-APR-15:51 | 5624.03 | 01-APR-19:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 107.82 | 24-MAY-15:00 | 2868.42 | 08-MAY-24:00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 536.22 | 24-JUN-17:02 | 1924.93 | 20-JUN-03:53 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 828.53 | 23-JUL-15:00 | 1815.35 | 06-JUL-22:00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 256.04 | 08-AUG-16:00 | 2578.27 | 27-AUG-06:00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.96 | 01-SEP-15:00 | 3403.61 | 20-SEP-01:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 4332.68 | 31-OCT-21:03 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 7868.22 | 22-NOV-02:00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 10269.31 | 16-DEC-05:51 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1815.35 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 828.53 | 12983.42 |
Report: PeakSpaceGainsMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 11441.73 | 04-JAN-06:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 13449.72 | 12-FEB-23:00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 7115.29 | 15-MAR-05:00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 410.98 | 23-APR-16:00 | 5746.33 | 01-APR-18:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.32 | 24-MAY-15:00 | 3209.70 | 29-MAY-18:00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 469.73 | 24-JUN-17:02 | 2100.21 | 20-JUN-03:53 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 627.83 | 15-JUL-17:02 | 2004.57 | 06-JUL-21:53 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 264.96 | 08-AUG-16:00 | 2890.76 | 27-AUG-06:00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.47 | 01-SEP-16:00 | 3587.57 | 20-SEP-01:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 4826.60 | 31-OCT-21:03 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 7939.68 | 22-NOV-02:00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 11277.48 | 16-DEC-06:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2004.57 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 627.83 | 13449.72 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BASEMENT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 104178.04 | 31-JAN-05:19 | 0.00 | 23328.51 | 134575.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 106865.47 | 21-FEB-05:01 | 0.00 | 23328.51 | 134575.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 109759.67 | 20-MAR-03:11 | 0.00 | 9331.40 | 107660.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 109991.31 | 10-APR-03:01 | 0.00 | 9331.40 | 107660.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 110756.30 | 22-MAY-03:02 | 0.00 | 6998.55 | 80745.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 109355.83 | 05-JUN-03:02 | 0.00 | 6998.55 | 80745.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 111393.93 | 10-JUL-03:02 | 0.00 | 5832.13 | 67287.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 109632.59 | 25-AUG-03:02 | 0.00 | 6998.55 | 80745.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 111588.94 | 25-SEP-03:02 | 0.00 | 5832.13 | 67287.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 114370.80 | 02-OCT-03:02 | 0.00 | 6998.55 | 80745.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 111988.85 | 20-NOV-04:01 | 0.00 | 8164.98 | 94202.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 107593.78 | 18-DEC-05:01 | 0.00 | 23328.51 | 134575.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 104178.04 | 0.00 | 5832.13 | 67287.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 114370.80 | 0.00 | 23328.51 | 134575.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 76561.72 | 20-JAN-06:01 | 11285.67 | 14665.45 | 56400.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 85592.28 | 09-FEB-06:01 | 11285.67 | 14665.45 | 56400.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 87645.76 | 28-MAR-04:01 | 0.00 | 16760.51 | 64457.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 89366.15 | 25-APR-03:02 | 0.00 | 5237.66 | 40285.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 90293.08 | 08-MAY-03:02 | 0.00 | 5237.66 | 40285.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 93567.19 | 19-JUN-03:02 | 0.00 | 6285.19 | 48342.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 91304.82 | 17-JUL-03:02 | 0.00 | 6285.19 | 48342.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 90171.39 | 18-AUG-03:02 | 0.00 | 6285.19 | 48342.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 92616.42 | 11-SEP-03:02 | 0.00 | 5237.66 | 40285.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 92643.40 | 23-OCT-03:02 | 0.00 | 5237.66 | 40285.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 89402.29 | 13-NOV-05:02 | 0.00 | 20950.64 | 80571.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 84677.95 | 29-DEC-06:01 | 12897.91 | 16760.51 | 64457.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 76561.72 | 0.00 | 5237.66 | 40285.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 93567.19 | 12897.91 | 20950.64 | 80571.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_MID
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 18912.83 | 06-JAN-09:00 | 15316.26 | 18854.65 | 18128.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 29255.66 | 08-FEB-11:25 | 30632.53 | 37709.30 | 36257.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 72122.85 | 30-MAR-05:03 | 6448.95 | 8380.26 | 32228.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 79975.83 | 24-APR-05:02 | 8061.19 | 10475.32 | 40285.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 89870.18 | 30-MAY-03:02 | 0.00 | 5237.66 | 40285.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 84030.89 | 28-JUN-03:02 | 0.00 | 6285.19 | 48342.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 86919.93 | 05-JUL-03:02 | 0.00 | 6285.19 | 48342.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 83607.20 | 10-AUG-03:02 | 0.00 | 6285.19 | 48342.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 81925.96 | 02-SEP-04:02 | 0.00 | 5237.66 | 30214.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 78417.05 | 20-OCT-05:03 | 6448.95 | 8380.26 | 32228.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 68986.30 | 22-NOV-13:50 | 76581.32 | 94273.24 | 90642.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 20707.55 | 01-DEC-17:00 | 15316.26 | 18854.65 | 18128.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 18912.83 | 0.00 | 5237.66 | 18128.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 89870.18 | 76581.32 | 94273.24 | 90642.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_TOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 16749.52 | 20-JAN-17:00 | 15316.26 | 18854.65 | 18128.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 18623.21 | 08-FEB-17:00 | 15316.26 | 18854.65 | 18128.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 26745.76 | 29-MAR-16:00 | 15316.26 | 18854.65 | 18128.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 41144.84 | 14-APR-05:03 | 4836.72 | 6285.19 | 24171.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 80624.16 | 25-MAY-04:02 | 0.00 | 10475.32 | 40285.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 82968.74 | 29-JUN-03:02 | 0.00 | 6285.19 | 48342.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 85514.62 | 05-JUL-03:02 | 0.00 | 6285.19 | 48342.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 83052.85 | 09-AUG-03:02 | 0.00 | 6285.19 | 48342.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 80215.46 | 01-SEP-04:02 | 0.00 | 10475.32 | 40285.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 37730.97 | 20-OCT-16:00 | 15316.26 | 18854.65 | 18128.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 20712.45 | 17-NOV-17:00 | 15316.26 | 18854.65 | 18128.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 16815.32 | 28-DEC-17:00 | 15316.26 | 18854.65 | 18128.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 16749.52 | 0.00 | 6285.19 | 18128.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 85514.62 | 15316.26 | 18854.65 | 48342.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2293.05 | 19-JAN-14:20 | 2010.79 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 178.38 |
February | 3035.95 | 27-FEB-15:10 | 5769.33 | 4362.86 | 6828.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 333.44 |
March | 4328.44 | 28-MAR-14:00 | 2010.79 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 131.83 |
April | 6615.29 | 18-APR-14:00 | 2010.79 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110.13 |
May | 10323.39 | 24-MAY-05:02 | 1012.16 | 807.98 | 5058.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.89 |
June | 12941.76 | 28-JUN-05:03 | 809.73 | 646.38 | 4046.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 13148.65 | 24-JUL-05:03 | 809.73 | 646.38 | 4046.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.58 |
August | 12470.31 | 14-AUG-05:03 | 809.73 | 1052.22 | 4046.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.02 |
September | 7622.99 | 01-SEP-15:10 | 1923.11 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 12.51 | 0.00 |
October | 5509.72 | 02-OCT-13:10 | 2010.79 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.73 |
November | 4061.64 | 01-NOV-13:40 | 2010.79 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.96 |
December | 2836.28 | 29-DEC-06:02 | 1619.46 | 2104.45 | 8093.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 158.76 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2293.05 | 809.73 | 646.38 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 13148.65 | 5769.33 | 4362.86 | 8093.57 | 0.00 | 0.00 | 0.00 | 0.00 | 12.51 | 333.44 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3169.26 | 27-JAN-11:30 | 2478.65 | 1874.40 | 2933.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.65 |
February | 4247.94 | 28-FEB-10:15 | 2591.66 | 1874.40 | 2933.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 127.23 |
March | 11020.38 | 20-MAR-09:20 | 3887.49 | 2811.59 | 4400.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74.23 |
April | 11644.97 | 19-APR-08:20 | 1239.33 | 937.20 | 1466.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 274.10 |
May | 21862.12 | 21-MAY-08:32 | 326.14 | 260.35 | 2444.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 175.84 |
June | 20174.35 | 25-JUN-07:52 | 326.14 | 260.35 | 2444.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.08 |
July | 18232.86 | 23-JUL-09:32 | 326.14 | 260.35 | 2444.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.73 |
August | 23011.83 | 20-AUG-08:32 | 391.37 | 312.41 | 2933.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 258.77 |
September | 14263.25 | 10-SEP-09:53 | 260.91 | 208.28 | 1955.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 216.74 |
October | 8633.56 | 19-OCT-09:10 | 1295.83 | 937.20 | 1466.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.94 |
November | 4467.12 | 10-NOV-12:40 | 2046.05 | 2811.59 | 3911.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 199.60 |
December | 3762.79 | 07-DEC-06:02 | 1043.64 | 1356.19 | 5215.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 131.64 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 3169.26 | 260.91 | 208.28 | 1466.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.73 | |
Maximum of Months | 23011.83 | 3887.49 | 2811.59 | 5215.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 274.10 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 13002.81 | 27-JAN-13:30 | 1923.15 | 1454.32 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 19055.35 | 27-FEB-15:10 | 5769.46 | 4362.96 | 6829.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 359.59 |
March | 21664.06 | 17-MAR-13:30 | 6032.50 | 4362.96 | 6829.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 149.49 |
April | 26552.23 | 23-APR-13:22 | 506.09 | 404.00 | 3793.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 238.41 |
May | 23009.26 | 21-MAY-14:32 | 607.31 | 484.80 | 4552.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 123.12 |
June | 17016.62 | 30-JUN-12:40 | 1923.15 | 1454.32 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 68.53 | 0.00 |
July | 27241.38 | 16-JUL-12:52 | 506.09 | 404.00 | 3793.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 144.48 |
August | 28467.08 | 20-AUG-12:32 | 607.31 | 484.80 | 4552.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 130.86 |
September | 27752.06 | 03-SEP-14:32 | 607.31 | 484.80 | 4552.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 310.70 |
October | 30293.41 | 22-OCT-12:41 | 708.53 | 565.60 | 5311.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 317.91 |
November | 22122.08 | 10-NOV-13:00 | 3175.00 | 4362.96 | 6070.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 313.31 |
December | 10200.56 | 20-DEC-13:30 | 1923.15 | 1454.32 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 309.21 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 10200.56 | 506.09 | 404.00 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 30293.41 | 6032.50 | 4362.96 | 6829.06 | 0.00 | 0.00 | 0.00 | 0.00 | 68.53 | 359.59 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4875.13 | 27-JAN-15:40 | 3717.98 | 2811.59 | 4400.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 8939.21 | 27-FEB-17:10 | 782.73 | 1041.34 | 1629.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 184.55 |
March | 19876.97 | 26-MAR-17:12 | 0.00 | 260.35 | 2444.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 392.95 |
April | 28147.12 | 23-APR-16:41 | 456.59 | 364.48 | 3422.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75.70 |
May | 27207.52 | 21-MAY-15:52 | 391.37 | 312.41 | 2933.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 101.43 |
June | 26224.81 | 17-JUN-17:42 | 391.37 | 312.41 | 2933.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.71 |
July | 27911.86 | 16-JUL-16:11 | 521.82 | 416.55 | 3911.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 198.98 |
August | 26637.12 | 05-AUG-17:42 | 391.37 | 312.41 | 2933.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74.99 |
September | 28615.61 | 03-SEP-17:11 | 0.00 | 364.48 | 3422.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 175.50 |
October | 19279.65 | 22-OCT-14:42 | 391.37 | 312.41 | 2933.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 181.80 |
November | 7842.22 | 09-NOV-15:40 | 1239.33 | 937.20 | 1466.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 202.86 |
December | 5475.92 | 28-DEC-06:02 | 1043.64 | 1356.19 | 5215.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83.80 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 4875.13 | 0.00 | 260.35 | 1466.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 28615.61 | 3717.98 | 2811.59 | 5215.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 392.95 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1605.64 | 28-JAN-17:01 | 708.51 | 920.70 | 5311.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 774.50 |
February | 2352.43 | 08-FEB-17:05 | 1214.60 | 2367.99 | 2529.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 228.56 |
March | 4139.78 | 10-MAR-14:33 | 6032.37 | 4362.86 | 6828.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 293.97 |
April | 4666.71 | 05-APR-12:58 | 7692.44 | 5817.15 | 9105.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 512.07 |
May | 8975.05 | 24-MAY-05:02 | 1012.16 | 807.98 | 5058.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.47 |
June | 12151.02 | 30-JUN-03:02 | 0.00 | 789.17 | 6070.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.68 |
July | 11638.17 | 01-JUL-05:02 | 1012.16 | 807.98 | 5058.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 128.49 |
August | 8260.85 | 09-AUG-15:30 | 1923.11 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 38.76 | 0.00 |
September | 6907.14 | 01-SEP-15:40 | 1923.11 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 25.83 | 0.00 |
October | 4122.91 | 13-OCT-12:58 | 7692.44 | 5817.15 | 9105.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 326.82 |
November | 3782.55 | 02-NOV-08:50 | 1923.11 | 1619.46 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 470.53 |
December | 1624.36 | 30-DEC-17:02 | 607.30 | 789.17 | 4552.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 79.40 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1605.64 | 0.00 | 789.17 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 12151.02 | 7692.44 | 5817.15 | 9105.27 | 0.00 | 0.00 | 0.00 | 0.00 | 38.76 | 774.50 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2646.04 | 11-JAN-06:04 | 913.19 | 1186.66 | 4563.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 5096.76 | 08-FEB-11:25 | 2478.65 | 1874.40 | 2933.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 142.62 |
March | 7338.76 | 31-MAR-10:15 | 2478.65 | 1874.40 | 2933.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 388.56 |
April | 10982.86 | 19-APR-08:40 | 1239.33 | 937.20 | 1466.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 658.13 |
May | 22949.77 | 21-MAY-09:02 | 326.14 | 260.35 | 2444.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 357.75 |
June | 23969.75 | 18-JUN-08:62 | 391.37 | 312.41 | 2933.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 577.02 |
July | 22371.50 | 23-JUL-09:32 | 326.14 | 260.35 | 2444.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.17 |
August | 20340.47 | 20-AUG-09:22 | 326.14 | 260.35 | 2444.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 431.15 |
September | 17399.39 | 10-SEP-09:02 | 326.14 | 260.35 | 2444.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 480.32 |
October | 6881.30 | 19-OCT-08:55 | 2478.65 | 1874.40 | 2933.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 150.45 |
November | 3545.50 | 22-NOV-13:50 | 6196.63 | 4685.99 | 7334.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 606.34 |
December | 2654.39 | 28-DEC-06:04 | 1043.64 | 1356.19 | 5215.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 185.01 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2646.04 | 326.14 | 260.35 | 1466.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 23969.75 | 6196.63 | 4685.99 | 7334.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 658.13 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 12976.16 | 27-JAN-13:40 | 1923.15 | 1454.32 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 17662.03 | 28-FEB-13:40 | 1923.15 | 1454.32 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 482.38 |
March | 27113.22 | 19-MAR-13:32 | 506.09 | 404.00 | 3793.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 689.50 |
April | 27093.75 | 23-APR-14:02 | 506.09 | 404.00 | 3793.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 435.47 |
May | 26052.53 | 21-MAY-15:02 | 607.31 | 484.80 | 4552.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 278.45 |
June | 26596.89 | 18-JUN-14:02 | 506.09 | 404.00 | 3793.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.16 |
July | 27878.28 | 16-JUL-14:12 | 607.31 | 484.80 | 4552.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 339.05 |
August | 27002.15 | 13-AUG-13:32 | 506.09 | 404.00 | 3793.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 358.20 |
September | 28523.55 | 03-SEP-14:32 | 607.31 | 484.80 | 4552.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 757.81 |
October | 28905.87 | 22-OCT-13:02 | 607.31 | 484.80 | 4552.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 630.92 |
November | 19140.22 | 07-NOV-13:07 | 5769.46 | 4362.96 | 6829.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 464.06 |
December | 8084.94 | 02-DEC-13:30 | 202.44 | 242.38 | 885.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 152.25 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 8084.94 | 202.44 | 242.38 | 885.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 28905.87 | 5769.46 | 4362.96 | 6829.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 757.81 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3336.64 | 27-JAN-16:00 | 2478.65 | 1874.40 | 2933.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 5075.68 | 22-FEB-15:57 | 3717.98 | 2811.59 | 4400.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 324.94 |
March | 11756.98 | 10-MAR-16:00 | 3717.98 | 2811.59 | 4400.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 24826.96 | 23-APR-16:41 | 456.59 | 364.48 | 3422.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 147.17 |
May | 26418.68 | 14-MAY-17:21 | 0.00 | 416.55 | 3911.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 596.02 |
June | 24105.14 | 17-JUN-17:42 | 391.37 | 312.41 | 2933.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.52 |
July | 26189.28 | 04-JUL-16:31 | 456.59 | 364.48 | 3422.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 161.68 |
August | 23924.69 | 05-AUG-17:42 | 391.37 | 312.41 | 2933.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 171.46 |
September | 25990.64 | 03-SEP-17:11 | 0.00 | 364.48 | 3422.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 416.67 |
October | 8591.55 | 19-OCT-16:00 | 1239.33 | 937.20 | 1466.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.92 |
November | 5766.63 | 09-NOV-16:45 | 2478.65 | 3051.27 | 2933.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 429.92 |
December | 2836.94 | 06-DEC-06:03 | 913.19 | 1186.66 | 4563.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 235.74 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2836.94 | 0.00 | 312.41 | 1466.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 26418.68 | 3717.98 | 3051.27 | 4563.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 596.02 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2051.10 | 28-JAN-17:01 | 708.51 | 920.70 | 5311.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 960.47 |
February | 2091.63 | 04-FEB-17:02 | 506.08 | 657.64 | 3793.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 429.09 |
March | 2939.90 | 28-MAR-15:40 | 1923.11 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 379.26 |
April | 4416.45 | 23-APR-17:11 | 0.00 | 807.98 | 7587.73 | 0.00 | 0.00 | 0.00 | 0.00 | 403.30 | 0.00 |
May | 8623.29 | 24-MAY-14:30 | 1923.11 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 86.45 | 0.00 |
June | 14312.70 | 28-JUN-05:03 | 809.73 | 646.38 | 4046.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 11409.09 | 21-JUL-05:03 | 809.73 | 646.38 | 4046.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.26 |
August | 8839.50 | 09-AUG-15:30 | 1923.11 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 46.45 | 0.00 |
September | 7388.52 | 01-SEP-15:40 | 1923.11 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 30.32 | 0.00 |
October | 3657.15 | 20-OCT-13:20 | 2010.79 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97.27 |
November | 2700.29 | 01-NOV-16:00 | 1923.11 | 1454.29 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.09 |
December | 2086.46 | 30-DEC-17:02 | 607.30 | 789.17 | 4552.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98.55 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2051.10 | 0.00 | 646.38 | 2276.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 14312.70 | 2010.79 | 1454.29 | 7587.73 | 0.00 | 0.00 | 0.00 | 0.00 | 403.30 | 960.47 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2725.55 | 19-JAN-06:04 | 913.19 | 1186.66 | 4563.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 235.33 |
February | 2783.01 | 28-FEB-10:30 | 2591.66 | 1874.40 | 2933.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 325.31 |
March | 3883.70 | 31-MAR-10:15 | 2478.65 | 1874.40 | 2933.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 479.79 |
April | 9867.83 | 18-APR-09:30 | 1295.83 | 937.20 | 1466.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 174.57 |
May | 13203.55 | 18-MAY-09:20 | 1295.83 | 937.20 | 1466.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.90 | 0.00 |
June | 24552.14 | 18-JUN-09:51 | 456.59 | 364.48 | 3422.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 425.49 |
July | 22667.25 | 23-JUL-09:32 | 326.14 | 260.35 | 2444.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.34 |
August | 23566.81 | 20-AUG-09:42 | 391.37 | 312.41 | 2933.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 551.74 |
September | 11999.55 | 01-SEP-09:20 | 1295.83 | 937.20 | 1466.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.61 |
October | 5725.17 | 19-OCT-09:40 | 1295.83 | 937.20 | 1466.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 189.10 |
November | 2906.70 | 16-NOV-10:05 | 2591.66 | 1874.40 | 2933.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 263.04 |
December | 2627.72 | 06-DEC-06:04 | 913.19 | 1186.66 | 4563.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 293.10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2627.72 | 326.14 | 260.35 | 1466.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 24552.14 | 2591.66 | 1874.40 | 4563.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.90 | 551.74 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 9805.64 | 27-JAN-14:10 | 2010.83 | 1454.32 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 16208.72 | 28-FEB-14:10 | 2010.83 | 1454.32 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 665.93 |
March | 16618.94 | 23-MAR-14:00 | 2010.83 | 1454.32 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 28908.70 | 23-APR-14:31 | 809.75 | 646.40 | 6070.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 451.22 |
May | 18698.55 | 18-MAY-13:20 | 2010.83 | 1454.32 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 73.67 | 0.00 |
June | 28728.46 | 18-JUN-13:12 | 506.09 | 404.00 | 3793.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 177.95 |
July | 28921.25 | 23-JUL-13:32 | 506.09 | 404.00 | 3793.92 | 0.00 | 0.00 | 0.00 | 0.00 | 257.05 | 0.00 |
August | 30653.00 | 13-AUG-13:22 | 607.31 | 484.80 | 4552.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 569.46 |
September | 28658.80 | 04-SEP-12:52 | 506.09 | 404.00 | 3793.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1434.02 |
October | 31560.31 | 22-OCT-14:11 | 708.53 | 565.60 | 5311.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 812.87 |
November | 13654.91 | 17-NOV-13:30 | 1923.15 | 1454.32 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 541.07 |
December | 4916.93 | 20-DEC-14:10 | 6032.50 | 4362.96 | 6829.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 902.16 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 4916.93 | 506.09 | 404.00 | 2276.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 31560.31 | 6032.50 | 4362.96 | 6829.06 | 0.00 | 0.00 | 0.00 | 0.00 | 257.05 | 1434.02 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3066.13 | 27-JAN-15:55 | 2478.65 | 1874.40 | 2933.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 4296.69 | 08-FEB-16:40 | 1239.33 | 937.20 | 1466.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 256.81 |
March | 7921.10 | 28-MAR-17:00 | 391.37 | 520.67 | 814.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 124.26 |
April | 26473.60 | 23-APR-17:11 | 0.00 | 520.69 | 4889.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 255.63 |
May | 27158.40 | 14-MAY-17:21 | 0.00 | 416.55 | 3911.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 722.75 |
June | 25230.92 | 17-JUN-17:42 | 391.37 | 312.41 | 2933.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 150.25 |
July | 27484.94 | 04-JUL-16:31 | 456.59 | 364.48 | 3422.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 207.45 |
August | 25015.95 | 05-AUG-17:42 | 391.37 | 312.41 | 2933.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 215.42 |
September | 20356.82 | 03-SEP-17:22 | 0.00 | 260.35 | 2444.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 444.65 |
October | 8435.89 | 19-OCT-16:00 | 1239.33 | 937.20 | 1466.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.02 |
November | 3744.42 | 17-NOV-15:40 | 1239.33 | 937.20 | 1466.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 297.22 |
December | 3021.10 | 28-DEC-06:04 | 1043.64 | 1356.19 | 5215.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 230.86 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 3021.10 | 0.00 | 260.35 | 814.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 27484.94 | 2478.65 | 1874.40 | 5215.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 722.75 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: GROUNDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5094.36 | 23-JAN-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2626.07 |
February | 5504.10 | 13-FEB-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4418.87 |
March | 4850.01 | 27-MAR-05:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.86 |
April | 6059.24 | 24-APR-05:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 286.12 |
May | 9325.07 | 30-MAY-05:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 224.43 |
June | 8456.34 | 30-JUN-15:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 141.38 | 0.00 |
July | 11292.35 | 17-JUL-05:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 121.00 |
August | 10779.65 | 14-AUG-05:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 121.75 |
September | 8025.40 | 06-SEP-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.47 |
October | 7862.61 | 23-OCT-05:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 155.47 |
November | 5049.79 | 15-NOV-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 212.72 |
December | 3942.75 | 02-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 431.71 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 3942.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 11292.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 141.38 | 4418.87 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 7386.56 | 13-JAN-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 8753.12 | 25-FEB-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 7111.04 | 06-MAR-04:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4760.62 |
April | 6215.96 | 03-APR-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2543.14 |
May | 8066.10 | 30-MAY-05:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 400.69 |
June | 7900.65 | 28-JUN-05:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 8051.92 | 21-JUL-05:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74.15 |
August | 7581.73 | 10-AUG-05:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.57 |
September | 6961.42 | 02-SEP-05:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 208.16 |
October | 6295.08 | 30-OCT-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1335.84 |
November | 9340.56 | 24-NOV-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1792.70 |
December | 9653.30 | 02-DEC-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3868.19 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 6215.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 9653.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4760.62 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3846.37 |
February | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6691.67 |
March | 2122.83 | 31-MAR-15:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 662.78 |
April | 8725.17 | 13-APR-14:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 193.03 |
May | 17176.80 | 18-MAY-14:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.22 | 0.00 |
June | 19784.66 | 30-JUN-14:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 353.33 | 0.00 |
July | 18308.22 | 24-JUL-14:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 117.45 | 0.00 |
August | 16487.52 | 08-AUG-15:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 245.40 | 0.00 |
September | 13878.58 | 01-SEP-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.47 | 0.00 |
October | 6037.75 | 20-OCT-13:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 212.04 |
November | 2142.22 | 01-NOV-16:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 104.57 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4182.28 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 19784.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 353.33 | 6691.67 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: DATACENTER_BOT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 2021.50 | 25-JAN-16:30 | 222.14 | 520.85 | 1948.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 4426.89 | 27-FEB-16:55 | 444.28 | 1041.69 | 7794.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 7065.95 | 31-MAR-24:00 | 0.00 | 28.94 | 7794.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 8474.57 | 21-APR-18:10 | 23.38 | 173.61 | 7794.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 3290.74 | 31-MAY-24:00 | 0.00 | 28.94 | 3897.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 5371.42 | 30-JUN-23:23 | 0.00 | 115.75 | 23383.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 7252.94 | 31-JUL-23:42 | 0.00 | 115.75 | 31177.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 8358.72 | 13-AUG-18:40 | 0.00 | 144.69 | 38972.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 3324.65 | 30-SEP-24:00 | 0.00 | 28.94 | 3897.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 4868.26 | 31-OCT-24:00 | 0.00 | 28.94 | 5845.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6042.23 | 09-NOV-16:10 | 222.14 | 520.85 | 5845.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 7630.57 | 20-DEC-16:00 | 444.28 | 1041.69 | 15588.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 2021.50 | 0.00 | 28.94 | 1948.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 8474.57 | 444.28 | 1041.69 | 38972.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: DATACENTER_MID_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 1610.46 | 27-JAN-16:25 | 444.28 | 1041.69 | 3897.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 3795.05 | 08-FEB-17:00 | 222.14 | 520.85 | 3897.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6326.88 | 31-MAR-23:30 | 0.00 | 28.94 | 7794.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 8068.09 | 21-APR-18:10 | 23.38 | 173.61 | 7794.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 2904.15 | 31-MAY-24:00 | 0.00 | 28.94 | 3897.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 5271.58 | 30-JUN-23:55 | 0.00 | 57.88 | 11691.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6926.61 | 31-JUL-23:55 | 0.00 | 57.88 | 15588.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 7962.87 | 02-AUG-18:40 | 23.38 | 173.61 | 7794.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 2880.93 | 30-SEP-23:50 | 0.00 | 28.94 | 3897.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 3997.73 | 18-OCT-16:50 | 70.15 | 289.36 | 3897.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 5449.73 | 09-NOV-16:20 | 222.14 | 520.85 | 5845.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6770.03 | 20-DEC-16:00 | 444.28 | 1041.69 | 15588.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 1610.46 | 0.00 | 28.94 | 3897.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 8068.09 | 444.28 | 1041.69 | 15588.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: DATACENTER_TOP_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 1273.22 | 20-JAN-16:30 | 222.14 | 520.85 | 1948.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 3699.80 | 08-FEB-17:00 | 222.14 | 520.85 | 3897.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 5855.34 | 31-MAR-23:20 | 0.00 | 28.94 | 7794.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 8037.47 | 21-APR-18:10 | 23.38 | 173.61 | 7794.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 2557.92 | 25-MAY-18:40 | 23.38 | 173.61 | 1948.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 5204.46 | 30-JUN-23:55 | 0.00 | 57.88 | 11691.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6838.69 | 31-JUL-23:55 | 0.00 | 57.88 | 15588.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 7996.20 | 02-AUG-18:40 | 23.38 | 173.61 | 7794.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 2631.27 | 05-SEP-17:50 | 23.38 | 173.61 | 1948.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 3979.47 | 19-OCT-16:50 | 70.15 | 289.36 | 3897.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 5241.84 | 09-NOV-16:20 | 222.14 | 520.85 | 5845.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6459.07 | 20-DEC-16:00 | 444.28 | 1041.69 | 15588.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 1273.22 | 0.00 | 28.94 | 1948.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 8037.47 | 444.28 | 1041.69 | 15588.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: DATACENTER_BASEMENT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 90828.34 | 20-JAN-17:00 | 4808.68 | 5919.59 | 94908.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 182896.74 | 22-FEB-17:00 | 4808.68 | 5919.59 | 189816.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 358325.42 | 31-MAR-24:00 | 0.00 | 328.88 | 379632.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 367337.55 | 19-APR-16:00 | 4808.68 | 5919.59 | 379632.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 175261.00 | 31-MAY-24:00 | 0.00 | 328.88 | 189816.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 268028.79 | 30-JUN-23:55 | 0.00 | 657.76 | 569448.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 360144.57 | 31-JUL-24:00 | 0.00 | 657.76 | 759265.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 370439.48 | 09-AUG-21:02 | 1518.53 | 3946.59 | 2277795.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 175856.06 | 30-SEP-24:00 | 0.00 | 328.88 | 189816.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 267242.69 | 31-OCT-24:00 | 0.00 | 328.88 | 284724.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 276268.74 | 17-NOV-17:00 | 4808.68 | 5919.59 | 284724.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 366940.80 | 06-DEC-16:45 | 9617.36 | 11839.17 | 759265.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 90828.34 | 0.00 | 328.88 | 94908.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 370439.48 | 9617.36 | 11839.17 | 2277795.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
January | 0.169160E+13 | 1114690.15 | 10-JAN-08:09 | 0.142147E+13 | 3383004.62 | 09-JAN-07:10 |
February | 0.187287E+13 | 1195189.09 | 03-FEB-08:09 | 0.720282E+12 | 2854412.76 | 14-FEB-07:10 |
March | 0.249685E+13 | 1492061.57 | 17-MAR-15:30 | 0.408988E+12 | 2134935.35 | 15-MAR-06:00 |
April | 0.278167E+13 | 1697840.62 | 13-APR-15:20 | 0.165004E+12 | 1506057.41 | 05-APR-06:10 |
May | 0.186101E+13 | 1515379.90 | 25-MAY-15:39 | 0.785748E+11 | 571835.29 | 02-MAY-06:10 |
June | 0.238063E+13 | 1778054.07 | 30-JUN-15:50 | 0.675690E+11 | 186495.00 | 03-JUN-06:10 |
July | 0.289569E+13 | 2029455.25 | 05-JUL-15:09 | 0.626709E+11 | 81981.56 | 03-JUL-11:39 |
August | 0.327572E+13 | 2059095.48 | 08-AUG-15:20 | 0.659491E+11 | 189341.35 | 19-AUG-06:19 |
September | 0.172334E+13 | 1493260.42 | 01-SEP-15:00 | 0.707074E+11 | 501713.65 | 06-SEP-06:10 |
October | 0.208758E+13 | 1401124.80 | 19-OCT-15:50 | 0.164278E+12 | 1374143.40 | 30-OCT-06:10 |
November | 0.239731E+13 | 1416253.85 | 16-NOV-16:30 | 0.387709E+12 | 1733262.46 | 27-NOV-07:10 |
December | 0.283774E+13 | 1546494.70 | 27-DEC-08:09 | 0.109842E+13 | 3112449.10 | 26-DEC-07:10 |
Annual Sum or Average | 0.283020E+14 | 0.471162E+13 | ||||
Minimum of Months | 0.169160E+13 | 1114690.15 | 0.626709E+11 | 81981.56 | ||
Maximum of Months | 0.327572E+13 | 2059095.48 | 0.142147E+13 | 3383004.62 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [J] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [J] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [J] | HUMIDIFIER:ELECTRICITY [J] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.315057E+12 | 0.778789E+11 | 0.811612E+12 | 0.164873E+12 | 0.190415E+12 | 0.310915E+11 | 0.00 | 0.812137E+11 | 0.509823E+10 | 0.601074E+10 | 0.835257E+10 | 0.00 | 0.00 |
February | 0.282157E+12 | 0.626956E+11 | 0.102011E+13 | 0.148926E+12 | 0.168956E+12 | 0.289006E+11 | 0.00 | 0.139005E+12 | 0.977681E+10 | 0.510281E+10 | 0.723979E+10 | 0.00 | 0.00 |
March | 0.332871E+12 | 0.590353E+11 | 0.146267E+13 | 0.165150E+12 | 0.190212E+12 | 0.315286E+11 | 0.00 | 0.223592E+12 | 0.189346E+11 | 0.491044E+10 | 0.794335E+10 | 0.00 | 0.00 |
April | 0.295890E+12 | 0.466932E+11 | 0.170311E+13 | 0.159524E+12 | 0.193915E+12 | 0.238118E+11 | 0.00 | 0.291204E+12 | 0.596000E+11 | 0.365670E+10 | 0.426732E+10 | 0.00 | 0.00 |
May | 0.317974E+12 | 0.399585E+11 | 0.820521E+12 | 0.165008E+12 | 0.231715E+12 | 0.439756E+11 | 0.00 | 0.167051E+12 | 0.716577E+11 | 0.984444E+09 | 0.216581E+10 | 0.00 | 0.00 |
June | 0.315995E+12 | 0.345370E+11 | 0.110677E+13 | 0.159786E+12 | 0.250409E+12 | 0.681883E+11 | 0.00 | 0.317200E+12 | 0.126034E+12 | 0.136505E+09 | 0.156686E+10 | 0.00 | 0.00 |
July | 0.296098E+12 | 0.372991E+11 | 0.143888E+13 | 0.164745E+12 | 0.266999E+12 | 0.843020E+11 | 0.00 | 0.451256E+12 | 0.153469E+12 | 0.00 | 0.264582E+10 | 0.00 | 0.00 |
August | 0.330683E+12 | 0.441224E+11 | 0.177780E+13 | 0.165149E+12 | 0.252184E+12 | 0.787125E+11 | 0.00 | 0.478549E+12 | 0.147046E+12 | 0.00 | 0.147699E+10 | 0.00 | 0.00 |
September | 0.296569E+12 | 0.525614E+11 | 0.784732E+12 | 0.159522E+12 | 0.206474E+12 | 0.347457E+11 | 0.00 | 0.131068E+12 | 0.559080E+11 | 0.148890E+09 | 0.161372E+10 | 0.00 | 0.00 |
October | 0.310288E+12 | 0.651317E+11 | 0.112899E+13 | 0.164871E+12 | 0.189811E+12 | 0.211148E+11 | 0.00 | 0.168850E+12 | 0.325612E+11 | 0.119275E+10 | 0.477026E+10 | 0.00 | 0.00 |
November | 0.310483E+12 | 0.725135E+11 | 0.140306E+13 | 0.159634E+12 | 0.177329E+12 | 0.228171E+11 | 0.00 | 0.216587E+12 | 0.251799E+11 | 0.352043E+10 | 0.618682E+10 | 0.00 | 0.00 |
December | 0.306024E+12 | 0.803892E+11 | 0.175516E+13 | 0.164749E+12 | 0.188879E+12 | 0.332946E+11 | 0.00 | 0.278742E+12 | 0.168858E+11 | 0.552762E+10 | 0.808587E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.371009E+13 | 0.672816E+12 | 0.152134E+14 | 0.194194E+13 | 0.250730E+13 | 0.502483E+12 | 0.00 | 0.294432E+13 | 0.722152E+12 | 0.311913E+11 | 0.563152E+11 | 0.00 | 0.00 |
Minimum of Months | 0.282157E+12 | 0.345370E+11 | 0.784732E+12 | 0.148926E+12 | 0.168956E+12 | 0.211148E+11 | 0.00 | 0.812137E+11 | 0.509823E+10 | 0.00 | 0.147699E+10 | 0.00 | 0.00 |
Maximum of Months | 0.332871E+12 | 0.803892E+11 | 0.177780E+13 | 0.165150E+12 | 0.266999E+12 | 0.843020E+11 | 0.00 | 0.478549E+12 | 0.153469E+12 | 0.601074E+10 | 0.835257E+10 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [J] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
January | 0.00 | 0.00 | 0.134835E+13 | 0.00 | 0.731132E+11 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.652768E+12 | 0.00 | 0.675146E+11 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.330851E+12 | 0.00 | 0.781371E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.948432E+11 | 0.00 | 0.701612E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.709495E+10 | 0.00 | 0.714799E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.353513E+09 | 0.00 | 0.672155E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 2664172.80 | 0.00 | 0.626682E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.361956E+09 | 0.00 | 0.655872E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.997786E+10 | 0.00 | 0.607295E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.998101E+11 | 0.00 | 0.644674E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.321882E+12 | 0.00 | 0.658272E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.102927E+13 | 0.00 | 0.691521E+11 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.389557E+13 | 0.00 | 0.816053E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 2664172.80 | 0.00 | 0.607295E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.134835E+13 | 0.00 | 0.781371E+11 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | EXTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY {Maximum} [W] | PUMPS:ELECTRICITY {TIMESTAMP} | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 352853.36 | 02-JAN-08:09 | 54335.80 | 01-JAN-06:10 | 439129.89 | 02-JAN-08:09 | 118959.22 | 02-JAN-08:20 | 115135.46 | 02-JAN-06:19 | 43656.08 | 04-JAN-06:19 | 0.00 | 01-JAN-00:10 |
February | 341217.84 | 02-FEB-16:00 | 54335.80 | 01-FEB-06:10 | 557421.28 | 01-FEB-08:09 | 118943.32 | 15-FEB-08:20 | 109049.71 | 08-FEB-16:19 | 43807.75 | 27-FEB-06:19 | 0.00 | 01-FEB-00:10 |
March | 336069.08 | 03-MAR-16:00 | 54335.80 | 01-MAR-06:10 | 675712.68 | 01-MAR-08:09 | 118944.62 | 13-MAR-07:19 | 280336.76 | 17-MAR-15:09 | 43475.07 | 06-MAR-06:10 | 0.00 | 01-MAR-00:10 |
April | 318095.48 | 03-APR-07:10 | 54335.80 | 01-APR-05:10 | 794004.08 | 03-APR-07:10 | 118930.21 | 03-APR-07:19 | 185627.62 | 13-APR-14:50 | 40582.37 | 05-APR-04:10 | 0.00 | 01-APR-00:10 |
May | 316816.17 | 01-MAY-07:10 | 54335.80 | 01-MAY-19:30 | 439129.89 | 01-MAY-07:10 | 118929.14 | 01-MAY-07:19 | 254725.96 | 18-MAY-14:39 | 62983.05 | 17-MAY-10:00 | 0.00 | 01-MAY-00:10 |
June | 316816.17 | 01-JUN-07:10 | 54335.80 | 01-JUN-19:00 | 557421.28 | 01-JUN-07:10 | 118929.14 | 01-JUN-07:19 | 259559.08 | 28-JUN-14:30 | 64582.72 | 07-JUN-13:39 | 0.00 | 01-JUN-00:10 |
July | 316816.17 | 03-JUL-07:10 | 54335.80 | 01-JUL-20:19 | 675712.68 | 03-JUL-07:10 | 118929.14 | 03-JUL-07:19 | 313629.03 | 05-JUL-10:50 | 81784.50 | 05-JUL-10:39 | 0.00 | 01-JUL-00:10 |
August | 329163.25 | 31-AUG-07:10 | 54335.80 | 01-AUG-19:49 | 794004.08 | 01-AUG-07:10 | 118939.43 | 31-AUG-07:19 | 269639.77 | 08-AUG-15:20 | 64231.61 | 31-AUG-12:50 | 0.00 | 01-AUG-00:10 |
September | 330263.05 | 19-SEP-07:10 | 54335.80 | 01-SEP-05:10 | 439129.89 | 01-SEP-07:10 | 118940.35 | 19-SEP-07:19 | 245858.37 | 01-SEP-15:00 | 64342.50 | 01-SEP-12:20 | 0.00 | 01-SEP-00:10 |
October | 351774.10 | 31-OCT-07:10 | 54335.80 | 01-OCT-05:10 | 557421.28 | 02-OCT-07:10 | 118958.32 | 31-OCT-07:19 | 174519.70 | 13-OCT-13:09 | 59501.48 | 19-OCT-13:39 | 0.00 | 01-OCT-00:10 |
November | 352853.36 | 06-NOV-16:49 | 54335.80 | 01-NOV-05:10 | 675712.68 | 01-NOV-07:10 | 118958.06 | 01-NOV-07:19 | 174616.53 | 03-NOV-10:00 | 42393.97 | 27-NOV-07:30 | 0.00 | 01-NOV-00:10 |
December | 352853.36 | 01-DEC-16:19 | 54335.80 | 01-DEC-06:10 | 794004.08 | 01-DEC-08:09 | 118959.22 | 26-DEC-08:20 | 114153.36 | 26-DEC-06:10 | 44333.52 | 11-DEC-07:49 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 316816.17 | 54335.80 | 439129.89 | 118929.14 | 109049.71 | 40582.37 | 0.00 | |||||||
Maximum of Months | 352853.36 | 54335.80 | 794004.08 | 118959.22 | 313629.03 | 81784.50 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY {Maximum} [W] | HEATREJECTION:ELECTRICITY {TIMESTAMP} | HUMIDIFIER:ELECTRICITY {Maximum} [W] | HUMIDIFIER:ELECTRICITY {TIMESTAMP} | HEATRECOVERY:ELECTRICITY {Maximum} [W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 38878.58 | 27-JAN-15:20 | 3533.12 | 29-JAN-14:00 | 6710.09 | 13-JAN-21:00 | 6524.59 | 02-JAN-07:10 | 0.00 | 0.00 |
February | 69645.06 | 07-FEB-15:30 | 13538.14 | 20-FEB-15:00 | 6736.07 | 01-FEB-21:00 | 6524.59 | 01-FEB-07:10 | 0.00 | 0.00 |
March | 106989.90 | 31-MAR-23:00 | 33761.82 | 26-MAR-15:00 | 6361.85 | 15-MAR-20:00 | 6524.59 | 01-MAR-07:10 | 0.00 | 0.00 |
April | 241278.81 | 23-APR-16:19 | 52251.23 | 23-APR-16:19 | 6143.20 | 04-APR-17:00 | 6524.59 | 01-APR-16:10 | 0.00 | 0.00 |
May | 281069.47 | 25-MAY-15:00 | 87722.25 | 16-MAY-12:09 | 5621.16 | 01-MAY-17:00 | 6524.59 | 10-MAY-14:00 | 0.00 | 0.00 |
June | 417090.84 | 19-JUN-15:09 | 87722.25 | 06-JUN-12:50 | 3301.44 | 03-JUN-11:00 | 6524.59 | 06-JUN-11:00 | 0.00 | 0.00 |
July | 505731.89 | 05-JUL-10:20 | 87722.25 | 03-JUL-12:09 | 0.00 | 01-JUL-00:10 | 6524.59 | 03-JUL-13:50 | 0.00 | 0.00 |
August | 486582.79 | 31-AUG-12:50 | 87722.25 | 04-AUG-13:30 | 0.00 | 01-AUG-00:10 | 6524.59 | 08-AUG-10:30 | 0.00 | 0.00 |
September | 278598.42 | 01-SEP-12:20 | 87722.25 | 01-SEP-08:00 | 2573.90 | 09-SEP-06:00 | 6524.59 | 01-SEP-14:09 | 0.00 | 0.00 |
October | 169801.37 | 19-OCT-13:50 | 51704.67 | 19-OCT-13:50 | 5141.40 | 31-OCT-20:00 | 6524.59 | 07-OCT-16:40 | 0.00 | 0.00 |
November | 149634.80 | 01-NOV-14:00 | 49785.16 | 01-NOV-14:00 | 6299.67 | 25-NOV-17:19 | 6524.59 | 04-NOV-06:00 | 0.00 | 0.00 |
December | 108955.87 | 09-DEC-06:00 | 14632.58 | 28-DEC-02:00 | 6694.91 | 09-DEC-17:00 | 6524.59 | 01-DEC-07:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||
Minimum of Months | 38878.58 | 3533.12 | 0.00 | 6524.59 | 0.00 | 0.00 | ||||
Maximum of Months | 505731.89 | 87722.25 | 6736.07 | 6524.59 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] | |
January | 1114690.15 | 10-JAN-08:09 | 352853.36 | 439129.89 | 54335.80 | 118765.30 | 84716.84 | 24212.24 | 0.00 | 28722.74 | 1466.87 |
February | 1195189.09 | 03-FEB-08:09 | 325596.97 | 557421.28 | 0.00 | 118759.08 | 82686.80 | 40508.55 | 0.00 | 57070.75 | 3294.13 |
March | 1492061.57 | 17-MAR-15:30 | 316816.17 | 675712.68 | 0.00 | 84885.75 | 273063.42 | 40001.28 | 0.00 | 87584.12 | 7009.89 |
April | 1697840.62 | 13-APR-15:20 | 316816.17 | 794004.08 | 0.00 | 84885.75 | 185494.66 | 39381.41 | 0.00 | 225236.60 | 49556.06 |
May | 1515379.90 | 25-MAY-15:39 | 316816.17 | 439129.89 | 0.00 | 84885.75 | 242046.05 | 60742.46 | 0.00 | 277512.74 | 87722.25 |
June | 1778054.07 | 30-JUN-15:50 | 316816.17 | 557421.28 | 0.00 | 84885.75 | 252840.59 | 62971.59 | 0.00 | 408871.84 | 87722.25 |
July | 2029455.25 | 05-JUL-15:09 | 316816.17 | 675712.68 | 0.00 | 84885.75 | 313629.03 | 81006.65 | 0.00 | 468771.59 | 87722.25 |
August | 2059095.48 | 08-AUG-15:20 | 316816.17 | 794004.08 | 0.00 | 84885.75 | 269639.77 | 61682.38 | 0.00 | 437820.49 | 87722.25 |
September | 1493260.42 | 01-SEP-15:00 | 316816.17 | 439129.89 | 0.00 | 84885.75 | 245858.37 | 60595.82 | 0.00 | 251727.58 | 87722.25 |
October | 1401124.80 | 19-OCT-15:50 | 320749.83 | 557421.28 | 0.00 | 84888.39 | 158444.08 | 59058.83 | 0.00 | 169420.49 | 51141.92 |
November | 1416253.85 | 16-NOV-16:30 | 352853.36 | 675712.68 | 54335.80 | 84906.22 | 99405.80 | 38927.82 | 0.00 | 88817.84 | 15533.03 |
December | 1546494.70 | 27-DEC-08:09 | 352853.36 | 794004.08 | 54335.80 | 118765.30 | 83579.09 | 23333.96 | 0.00 | 103659.67 | 6577.64 |
Annual Sum or Average | |||||||||||
Minimum of Months | 1114690.15 | 316816.17 | 439129.89 | 0.00 | 84885.75 | 82686.80 | 23333.96 | 0.00 | 28722.74 | 1466.87 | |
Maximum of Months | 2059095.48 | 352853.36 | 794004.08 | 54335.80 | 118765.30 | 313629.03 | 81006.65 | 0.00 | 468771.59 | 87722.25 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS {Maximum} [W] | WATERSYSTEMS:NATURALGAS {TIMESTAMP} | COGENERATION:NATURALGAS [] | |
January | 0.00 | 0.00 | 3353627.48 | 09-JAN-07:10 | 0.00 | 87247.44 | 31-JAN-12:50 | 0.00 |
February | 0.00 | 0.00 | 2823191.91 | 14-FEB-07:10 | 0.00 | 87558.57 | 23-FEB-12:50 | 0.00 |
March | 0.00 | 0.00 | 2103753.91 | 15-MAR-06:00 | 0.00 | 87511.59 | 01-MAR-12:39 | 0.00 |
April | 0.00 | 0.00 | 1478702.29 | 05-APR-06:10 | 0.00 | 86952.08 | 04-APR-11:39 | 0.00 |
May | 0.00 | 0.00 | 541591.26 | 02-MAY-06:10 | 0.00 | 85790.65 | 01-MAY-11:39 | 0.00 |
June | 0.00 | 0.00 | 158692.81 | 03-JUN-06:10 | 0.00 | 83988.98 | 01-JUN-11:20 | 0.00 |
July | 0.00 | 0.00 | 703.39 | 18-JUL-06:10 | 0.00 | 81981.56 | 03-JUL-11:39 | 0.00 |
August | 0.00 | 0.00 | 161713.36 | 19-AUG-06:19 | 0.00 | 80511.30 | 03-AUG-11:20 | 0.00 |
September | 0.00 | 0.00 | 472458.50 | 06-SEP-06:10 | 0.00 | 80811.59 | 28-SEP-11:39 | 0.00 |
October | 0.00 | 0.00 | 1344544.84 | 30-OCT-06:10 | 0.00 | 82609.16 | 31-OCT-11:39 | 0.00 |
November | 0.00 | 0.00 | 1703304.98 | 27-NOV-07:10 | 0.00 | 84495.65 | 30-NOV-12:39 | 0.00 |
December | 0.00 | 0.00 | 3082579.28 | 26-DEC-07:10 | 0.00 | 86118.90 | 29-DEC-12:00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 703.39 | 0.00 | 80511.30 | 0.00 | ||
Maximum of Months | 0.00 | 0.00 | 3353627.48 | 0.00 | 87558.57 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BASEMENT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 25.68 | 0.00 | 25.68 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 26.12 | 0.00 | 26.12 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.50 | 25.80 | 0.00 | 25.80 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 26.45 | 1.17 | 26.70 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 25.83 | 0.00 | 25.83 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 5.33 | 25.84 | 0.83 | 25.70 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 25.84 | 0.00 | 25.84 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 9.33 | 26.62 | 0.00 | 26.62 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 8.50 | 26.47 | 0.00 | 26.47 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 26.35 | 0.00 | 26.35 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 25.37 | 0.17 | 25.17 |
Annual Sum or Average | 0.00 | 0.00 | 40.67 | 26.24 | 2.17 | 26.24 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 9.33 | 26.62 | 1.17 | 26.70 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 25.59 | 0.00 | 25.59 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 24.74 | 2.17 | 24.74 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 25.59 | 0.00 | 25.59 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 25.66 | 0.00 | 25.66 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 25.67 | 0.00 | 25.67 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 3.00 | 24.98 | 2.17 | 24.88 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 25.67 | 2.17 | 25.67 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_MID
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.83 | 19.19 | 0.83 | 19.40 | 0.00 | 19.40 | 0.00 | 19.40 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 24.70 | 0.67 | 24.70 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.17 | 19.07 | 0.00 | 19.07 | 0.00 | 19.07 | 0.00 | 19.07 |
December | 0.50 | 18.86 | 0.00 | 18.86 | 0.00 | 18.86 | 0.00 | 18.86 |
Annual Sum or Average | 2.50 | 19.12 | 0.83 | 19.30 | 0.67 | 20.20 | 0.67 | 20.84 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1.83 | 19.19 | 0.83 | 19.40 | 0.67 | 24.70 | 0.67 | 24.70 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_TOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 9.50 | 18.72 | 2.17 | 18.95 | 0.00 | 18.95 | 0.00 | 18.95 |
February | 3.67 | 18.44 | 0.33 | 18.59 | 0.00 | 18.59 | 0.00 | 18.59 |
March | 1.33 | 18.47 | 0.00 | 18.47 | 0.00 | 18.47 | 0.00 | 18.47 |
April | 0.33 | 19.25 | 0.00 | 19.25 | 0.00 | 19.25 | 0.00 | 19.25 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.67 | 0.83 | 24.67 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.33 | 19.02 | 0.00 | 19.02 | 0.00 | 19.02 | 0.00 | 19.02 |
November | 2.50 | 18.65 | 0.17 | 18.76 | 0.00 | 18.76 | 0.00 | 18.76 |
December | 6.50 | 18.64 | 1.33 | 18.90 | 0.00 | 18.90 | 0.00 | 18.90 |
Annual Sum or Average | 24.17 | 18.65 | 4.00 | 18.85 | 0.83 | 19.02 | 0.83 | 19.17 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 9.50 | 19.25 | 2.17 | 19.25 | 0.83 | 24.67 | 0.83 | 24.67 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 6.83 | 18.83 | 1.33 | 19.03 | 0.00 | 19.03 | 0.00 | 19.03 |
February | 0.83 | 19.13 | 0.00 | 19.13 | 0.00 | 19.13 | 0.00 | 19.13 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 24.89 | 4.17 | 24.89 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 1.17 | 18.98 | 0.00 | 18.98 | 0.00 | 18.98 | 0.00 | 18.98 |
Annual Sum or Average | 8.83 | 18.88 | 1.33 | 19.03 | 4.17 | 20.74 | 4.17 | 21.67 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 6.83 | 19.13 | 1.33 | 19.13 | 4.17 | 24.89 | 4.17 | 24.89 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 5.50 | 18.50 | 0.50 | 18.66 | 0.00 | 18.66 | 0.00 | 18.66 |
February | 1.33 | 19.15 | 0.00 | 19.15 | 0.00 | 19.15 | 0.00 | 19.15 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.45 | 0.17 | 27.45 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 27.75 | 2.00 | 27.75 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 3.50 | 28.20 | 3.50 | 28.20 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 27.91 | 2.00 | 27.91 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 28.08 | 3.00 | 28.08 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 27.63 | 1.00 | 27.63 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 2.00 | 19.00 | 0.00 | 19.00 | 0.00 | 19.00 | 0.00 | 19.00 |
Annual Sum or Average | 8.83 | 18.71 | 0.50 | 18.80 | 11.67 | 23.90 | 11.67 | 25.36 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 5.50 | 19.15 | 0.50 | 19.15 | 3.50 | 28.20 | 3.50 | 28.20 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 5.83 | 18.47 | 0.67 | 18.52 | 0.00 | 18.52 | 0.00 | 18.52 |
February | 1.83 | 19.12 | 0.00 | 19.12 | 0.00 | 19.12 | 0.00 | 19.12 |
March | 0.17 | 19.14 | 0.00 | 19.14 | 1.67 | 26.93 | 1.67 | 27.30 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 28.16 | 1.17 | 28.16 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 27.33 | 0.50 | 27.33 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 27.69 | 1.17 | 27.69 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 26.32 | 6.00 | 26.32 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 4.67 | 27.94 | 4.67 | 27.94 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 3.33 | 28.09 | 3.33 | 28.09 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 28.11 | 3.00 | 28.11 |
November | 0.17 | 19.32 | 0.00 | 19.32 | 0.00 | 19.32 | 0.00 | 19.32 |
December | 2.50 | 18.83 | 0.00 | 18.83 | 0.00 | 18.83 | 0.00 | 18.83 |
Annual Sum or Average | 10.50 | 18.69 | 0.67 | 18.71 | 21.50 | 24.50 | 21.50 | 25.69 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.52 | 0.00 | 18.52 |
Maximum of Months | 5.83 | 19.32 | 0.67 | 19.32 | 6.00 | 28.16 | 6.00 | 28.16 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 2.67 | 18.96 | 0.00 | 18.96 | 0.00 | 18.96 | 0.00 | 18.96 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.29 | 0.17 | 27.29 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 27.89 | 1.17 | 27.80 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 28.31 | 2.00 | 28.29 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 4.67 | 28.22 | 2.17 | 28.23 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 27.72 | 2.00 | 27.75 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 17.50 | 27.88 | 6.00 | 28.01 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 16.83 | 27.62 | 5.17 | 27.79 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 28.10 | 1.00 | 28.17 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 27.63 | 0.50 | 27.63 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 2.67 | 18.96 | 0.00 | 18.96 | 53.33 | 27.42 | 20.17 | 27.63 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2.67 | 18.96 | 0.00 | 18.96 | 17.50 | 28.31 | 6.00 | 28.29 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 86.17 | 17.13 | 39.00 | 17.47 | 0.00 | 17.47 | 0.00 | 17.47 |
February | 42.00 | 17.35 | 13.33 | 17.63 | 0.00 | 17.63 | 0.00 | 17.63 |
March | 13.17 | 18.32 | 2.83 | 18.62 | 0.00 | 18.62 | 0.00 | 18.62 |
April | 0.83 | 19.24 | 0.00 | 19.24 | 0.00 | 19.24 | 0.00 | 19.24 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 24.78 | 3.00 | 24.78 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.17 | 19.26 | 0.00 | 19.26 | 0.00 | 19.26 | 0.00 | 19.26 |
November | 10.33 | 18.29 | 1.67 | 18.53 | 0.00 | 18.53 | 0.00 | 18.53 |
December | 78.33 | 16.75 | 30.67 | 16.98 | 0.00 | 16.98 | 0.00 | 16.98 |
Annual Sum or Average | 231.00 | 17.17 | 87.50 | 17.43 | 3.00 | 17.50 | 3.00 | 17.57 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 86.17 | 19.26 | 39.00 | 19.26 | 3.00 | 24.78 | 3.00 | 24.78 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 42.83 | 15.47 | 9.17 | 15.35 | 0.00 | 15.35 | 0.00 | 15.35 |
February | 19.33 | 16.14 | 1.00 | 16.07 | 0.00 | 16.07 | 0.00 | 16.07 |
March | 6.00 | 17.72 | 0.00 | 17.72 | 0.00 | 17.72 | 0.00 | 17.72 |
April | 0.83 | 19.26 | 0.00 | 19.26 | 0.00 | 19.26 | 0.00 | 19.26 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 27.83 | 1.33 | 27.83 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 28.32 | 3.83 | 28.32 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 2.50 | 28.06 | 2.50 | 28.06 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 28.08 | 3.17 | 28.08 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 27.43 | 0.33 | 27.43 |
October | 0.17 | 19.21 | 0.00 | 19.21 | 0.00 | 19.21 | 0.00 | 19.21 |
November | 6.83 | 17.16 | 0.17 | 17.11 | 0.00 | 17.11 | 0.00 | 17.11 |
December | 44.67 | 15.34 | 11.50 | 15.19 | 0.00 | 15.19 | 0.00 | 15.19 |
Annual Sum or Average | 120.67 | 15.77 | 21.83 | 15.60 | 11.17 | 16.51 | 11.17 | 17.30 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.19 | 0.00 | 15.19 |
Maximum of Months | 44.67 | 19.26 | 11.50 | 19.26 | 3.83 | 28.32 | 3.83 | 28.32 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 31.67 | 16.10 | 4.00 | 16.08 | 0.00 | 16.08 | 0.00 | 16.08 |
February | 13.33 | 16.82 | 0.83 | 16.84 | 0.00 | 16.84 | 0.00 | 16.84 |
March | 3.67 | 18.50 | 0.00 | 18.50 | 2.50 | 22.07 | 2.50 | 23.58 |
April | 0.50 | 19.33 | 0.00 | 19.33 | 1.33 | 25.72 | 1.33 | 26.73 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.55 | 0.83 | 27.55 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.74 | 0.83 | 27.74 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 26.92 | 4.17 | 26.92 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 28.00 | 4.17 | 28.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 28.04 | 4.00 | 28.04 |
October | 0.17 | 19.33 | 0.00 | 19.33 | 3.17 | 27.86 | 3.17 | 28.08 |
November | 4.33 | 18.01 | 0.00 | 18.01 | 0.00 | 18.01 | 0.00 | 18.01 |
December | 30.00 | 16.02 | 4.67 | 15.90 | 0.00 | 15.90 | 0.00 | 15.90 |
Annual Sum or Average | 83.67 | 16.42 | 9.50 | 16.34 | 21.00 | 18.43 | 21.00 | 19.88 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.90 | 0.00 | 15.90 |
Maximum of Months | 31.67 | 19.33 | 4.67 | 19.33 | 4.17 | 28.04 | 4.17 | 28.08 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 32.67 | 15.66 | 6.83 | 15.51 | 0.00 | 15.51 | 0.00 | 15.51 |
February | 12.17 | 16.74 | 0.83 | 16.63 | 0.00 | 16.63 | 0.00 | 16.63 |
March | 3.83 | 18.43 | 0.00 | 18.43 | 0.00 | 18.43 | 0.00 | 18.43 |
April | 0.17 | 19.25 | 0.00 | 19.25 | 1.33 | 27.58 | 0.67 | 27.92 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 3.50 | 28.32 | 1.33 | 28.35 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 28.09 | 0.83 | 28.02 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 28.33 | 3.17 | 28.40 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 28.08 | 2.33 | 28.06 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 28.22 | 0.67 | 28.24 |
October | 0.17 | 19.41 | 0.00 | 19.41 | 0.00 | 19.41 | 0.00 | 19.41 |
November | 4.00 | 18.32 | 0.00 | 18.32 | 0.00 | 18.32 | 0.00 | 18.32 |
December | 31.50 | 15.72 | 7.17 | 15.51 | 0.00 | 15.51 | 0.00 | 15.51 |
Annual Sum or Average | 84.50 | 16.10 | 14.83 | 15.89 | 18.33 | 17.82 | 9.00 | 18.57 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.51 | 0.00 | 15.51 |
Maximum of Months | 32.67 | 19.41 | 7.17 | 19.41 | 6.33 | 28.33 | 3.17 | 28.40 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 146.83 | 16.31 | 64.67 | 16.69 | 0.00 | 16.69 | 0.00 | 16.69 |
February | 93.50 | 16.39 | 33.33 | 16.75 | 0.00 | 16.75 | 0.00 | 16.75 |
March | 42.50 | 16.94 | 13.50 | 17.16 | 0.00 | 17.16 | 0.00 | 17.16 |
April | 9.00 | 17.19 | 1.50 | 17.11 | 0.00 | 17.11 | 0.00 | 17.11 |
May | 0.17 | 19.24 | 0.00 | 19.24 | 0.00 | 19.24 | 0.00 | 19.24 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 4.50 | 18.32 | 0.33 | 18.45 | 0.00 | 18.45 | 0.00 | 18.45 |
November | 45.67 | 16.25 | 15.67 | 16.30 | 0.00 | 16.30 | 0.00 | 16.30 |
December | 127.67 | 16.02 | 54.17 | 16.28 | 0.00 | 16.28 | 0.00 | 16.28 |
Annual Sum or Average | 469.83 | 16.34 | 183.17 | 16.61 | 0.00 | 16.61 | 0.00 | 16.61 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 146.83 | 19.24 | 64.67 | 19.24 | 0.00 | 19.24 | 0.00 | 19.24 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 82.00 | 14.93 | 21.17 | 14.85 | 0.00 | 14.85 | 0.00 | 14.85 |
February | 53.33 | 15.11 | 9.17 | 15.07 | 0.00 | 15.07 | 0.00 | 15.07 |
March | 23.17 | 16.16 | 2.17 | 16.08 | 0.00 | 16.08 | 0.00 | 16.08 |
April | 7.17 | 16.90 | 0.83 | 16.68 | 0.00 | 16.68 | 0.00 | 16.68 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 3.50 | 28.21 | 3.50 | 28.21 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 3.50 | 27.95 | 3.50 | 27.95 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 2.50 | 27.90 | 2.50 | 27.90 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 3.17 | 18.13 | 0.00 | 18.13 | 0.00 | 18.13 | 0.00 | 18.13 |
November | 34.17 | 15.41 | 8.67 | 15.25 | 0.00 | 15.25 | 0.00 | 15.25 |
December | 74.67 | 14.79 | 19.83 | 14.68 | 0.00 | 14.68 | 0.00 | 14.68 |
Annual Sum or Average | 277.67 | 15.18 | 61.83 | 15.06 | 9.50 | 15.41 | 9.50 | 15.75 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 82.00 | 18.13 | 21.17 | 18.13 | 3.50 | 28.21 | 3.50 | 28.21 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 76.67 | 15.46 | 19.50 | 15.51 | 0.00 | 15.51 | 0.00 | 15.51 |
February | 42.83 | 15.53 | 5.50 | 15.49 | 0.00 | 15.49 | 0.00 | 15.49 |
March | 18.67 | 16.70 | 1.83 | 16.62 | 0.00 | 16.62 | 0.00 | 16.62 |
April | 5.33 | 17.59 | 0.83 | 17.23 | 1.17 | 18.93 | 1.17 | 20.16 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 27.74 | 1.00 | 27.74 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 28.11 | 2.67 | 28.15 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 27.93 | 4.00 | 27.93 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 2.67 | 28.00 | 2.67 | 28.00 |
October | 2.33 | 18.20 | 0.00 | 18.20 | 1.83 | 22.56 | 1.83 | 24.26 |
November | 27.17 | 15.73 | 7.17 | 15.51 | 0.00 | 15.51 | 0.00 | 15.51 |
December | 69.50 | 15.38 | 15.67 | 15.36 | 0.00 | 15.36 | 0.00 | 15.36 |
Annual Sum or Average | 242.50 | 15.65 | 50.50 | 15.60 | 13.67 | 16.15 | 13.33 | 16.64 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 76.67 | 18.20 | 19.50 | 18.20 | 4.00 | 28.11 | 4.00 | 28.15 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 70.00 | 14.84 | 18.83 | 14.75 | 0.00 | 14.75 | 0.00 | 14.75 |
February | 38.67 | 15.19 | 6.50 | 15.12 | 0.00 | 15.12 | 0.00 | 15.12 |
March | 15.83 | 16.65 | 1.33 | 16.51 | 0.00 | 16.51 | 0.00 | 16.51 |
April | 3.67 | 18.39 | 0.00 | 18.39 | 1.17 | 20.84 | 0.67 | 21.74 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 3.33 | 28.08 | 1.33 | 28.07 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 28.18 | 0.67 | 28.10 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 6.50 | 28.32 | 3.17 | 28.40 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 28.00 | 2.17 | 28.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 28.28 | 0.67 | 28.23 |
October | 2.33 | 18.35 | 0.00 | 18.35 | 0.00 | 18.35 | 0.00 | 18.35 |
November | 24.33 | 15.68 | 6.83 | 15.50 | 0.00 | 15.50 | 0.00 | 15.50 |
December | 58.17 | 14.84 | 13.50 | 14.71 | 0.00 | 14.71 | 0.00 | 14.71 |
Annual Sum or Average | 213.00 | 15.24 | 47.00 | 15.09 | 17.83 | 15.93 | 8.67 | 16.30 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.71 | 0.00 | 14.71 |
Maximum of Months | 70.00 | 18.39 | 18.83 | 18.39 | 6.50 | 28.32 | 3.17 | 28.40 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: GROUNDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: DATACENTER_BOT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 5.33 | 28.71 | 2.17 | 28.55 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 5.33 | 28.71 | 2.17 | 28.55 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 5.33 | 28.71 | 2.17 | 28.55 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: DATACENTER_MID_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 | 28.55 | 0.83 | 28.41 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 3.67 | 28.55 | 0.83 | 28.41 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 | 28.55 | 0.83 | 28.41 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: DATACENTER_TOP_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 2.83 | 28.41 | 0.33 | 28.33 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 2.83 | 28.41 | 0.33 | 28.33 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 2.83 | 28.41 | 0.33 | 28.33 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: DATACENTER_BASEMENT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 28.37 | 4.00 | 28.38 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 66.50 | 28.17 | 66.50 | 28.17 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 72.83 | 28.18 | 70.50 | 28.18 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 66.50 | 28.37 | 66.50 | 28.38 |
Report: ComfortReportSimple55Monthly
For: BASEMENT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 460.17 | 23.61 | 0.00 | 23.61 | 0.00 | 23.61 |
February | 348.50 | 23.92 | 0.00 | 23.92 | 0.00 | 23.92 |
March | 331.17 | 24.01 | 10.67 | 24.07 | 0.00 | 24.07 |
April | 247.67 | 24.00 | 69.00 | 24.47 | 0.00 | 24.47 |
May | 76.00 | 24.00 | 215.00 | 24.75 | 12.33 | 24.72 |
June | 144.83 | 24.64 | 364.00 | 24.60 | 140.50 | 24.61 |
July | 166.00 | 25.10 | 483.67 | 24.74 | 166.00 | 24.81 |
August | 85.17 | 24.76 | 486.33 | 24.54 | 85.17 | 24.57 |
September | 10.67 | 24.00 | 237.17 | 25.05 | 10.67 | 25.00 |
October | 27.83 | 24.00 | 128.67 | 25.70 | 0.00 | 25.70 |
November | 193.83 | 24.00 | 88.00 | 24.60 | 0.00 | 24.60 |
December | 357.67 | 23.86 | 13.00 | 23.93 | 0.00 | 23.93 |
Annual Sum or Average | 2449.50 | 24.04 | 2095.50 | 24.43 | 414.67 | 24.46 |
Minimum of Months | 10.67 | 23.61 | 0.00 | 23.61 | 0.00 | 23.61 |
Maximum of Months | 460.17 | 25.10 | 486.33 | 25.70 | 166.00 | 25.70 |
Report: ComfortReportSimple55Monthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 23.29 | 15.50 | 23.21 | 15.50 | 23.14 |
February | 428.00 | 23.87 | 0.00 | 23.87 | 0.00 | 23.87 |
March | 345.33 | 23.95 | 4.83 | 23.98 | 0.00 | 23.98 |
April | 167.00 | 23.99 | 56.33 | 24.45 | 0.00 | 24.45 |
May | 63.00 | 23.99 | 199.00 | 24.49 | 0.00 | 24.49 |
June | 8.00 | 24.90 | 364.17 | 24.33 | 3.33 | 24.35 |
July | 3.00 | 24.67 | 490.50 | 24.30 | 3.00 | 24.30 |
August | 0.00 | 0.00 | 494.00 | 24.25 | 0.00 | 24.25 |
September | 4.83 | 23.84 | 235.00 | 24.61 | 0.00 | 24.61 |
October | 55.50 | 23.92 | 97.67 | 24.83 | 0.00 | 24.83 |
November | 220.67 | 23.96 | 48.17 | 24.18 | 0.00 | 24.18 |
December | 433.00 | 23.93 | 0.00 | 23.93 | 0.00 | 23.93 |
Annual Sum or Average | 2230.33 | 23.79 | 2005.17 | 24.10 | 21.83 | 24.09 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 23.21 | 0.00 | 23.14 |
Maximum of Months | 502.00 | 24.90 | 494.00 | 24.83 | 15.50 | 24.83 |
Report: ComfortReportSimple55Monthly
For: CORE_MID
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 21.43 | 208.00 | 21.10 | 208.00 | 20.92 |
February | 454.00 | 22.18 | 67.83 | 21.94 | 67.83 | 21.76 |
March | 512.50 | 23.04 | 8.00 | 23.01 | 8.00 | 22.98 |
April | 419.17 | 23.64 | 0.00 | 23.64 | 0.00 | 23.64 |
May | 138.33 | 23.79 | 154.50 | 24.19 | 0.00 | 24.19 |
June | 37.33 | 24.10 | 319.50 | 24.23 | 9.17 | 24.26 |
July | 3.17 | 24.30 | 469.83 | 24.29 | 2.83 | 24.29 |
August | 12.50 | 23.45 | 430.50 | 24.18 | 0.00 | 24.18 |
September | 94.17 | 23.57 | 136.33 | 24.12 | 0.00 | 24.12 |
October | 348.50 | 23.49 | 7.67 | 23.51 | 0.00 | 23.51 |
November | 466.17 | 22.93 | 34.00 | 22.79 | 30.17 | 22.66 |
December | 497.00 | 21.71 | 146.33 | 21.43 | 146.33 | 21.25 |
Annual Sum or Average | 3484.83 | 22.67 | 1982.50 | 22.93 | 472.33 | 22.74 |
Minimum of Months | 3.17 | 21.43 | 0.00 | 21.10 | 0.00 | 20.92 |
Maximum of Months | 512.50 | 24.30 | 469.83 | 24.29 | 208.00 | 24.29 |
Report: ComfortReportSimple55Monthly
For: CORE_TOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.43 | 391.83 | 20.26 | 391.83 | 20.20 |
February | 454.00 | 20.85 | 279.50 | 20.58 | 279.50 | 20.46 |
March | 514.00 | 21.59 | 188.67 | 21.26 | 188.67 | 21.07 |
April | 466.83 | 22.56 | 59.00 | 22.31 | 59.00 | 22.11 |
May | 202.67 | 23.30 | 143.17 | 23.78 | 2.00 | 23.76 |
June | 74.67 | 23.26 | 298.17 | 23.99 | 9.17 | 23.99 |
July | 25.67 | 23.43 | 442.67 | 24.23 | 3.00 | 24.23 |
August | 35.83 | 23.20 | 396.67 | 24.07 | 0.83 | 24.07 |
September | 227.33 | 23.20 | 80.50 | 23.47 | 8.50 | 23.49 |
October | 463.50 | 22.28 | 46.67 | 22.08 | 46.67 | 21.91 |
November | 488.33 | 21.32 | 192.00 | 20.92 | 192.00 | 20.69 |
December | 497.00 | 20.52 | 357.33 | 20.32 | 357.33 | 20.23 |
Annual Sum or Average | 3951.83 | 21.62 | 2876.17 | 21.80 | 1538.50 | 21.50 |
Minimum of Months | 25.67 | 20.43 | 46.67 | 20.26 | 0.83 | 20.20 |
Maximum of Months | 514.00 | 23.43 | 442.67 | 24.23 | 391.83 | 24.23 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.51 | 435.83 | 20.44 | 435.83 | 20.42 |
February | 454.00 | 21.16 | 265.33 | 20.99 | 265.33 | 20.91 |
March | 513.33 | 21.98 | 103.33 | 21.79 | 103.33 | 21.66 |
April | 439.17 | 23.23 | 7.67 | 23.24 | 2.00 | 23.23 |
May | 174.67 | 23.70 | 169.33 | 24.08 | 0.00 | 24.08 |
June | 9.33 | 23.71 | 366.00 | 24.28 | 0.00 | 24.28 |
July | 7.83 | 25.18 | 480.50 | 24.36 | 5.67 | 24.38 |
August | 8.33 | 23.47 | 459.33 | 24.19 | 0.00 | 24.19 |
September | 183.33 | 23.36 | 120.83 | 23.79 | 0.00 | 23.79 |
October | 434.83 | 23.08 | 2.67 | 23.09 | 0.00 | 23.09 |
November | 475.00 | 22.13 | 59.33 | 22.00 | 55.83 | 21.88 |
December | 497.00 | 20.85 | 324.00 | 20.69 | 324.00 | 20.62 |
Annual Sum or Average | 3698.83 | 21.99 | 2794.17 | 22.30 | 1192.00 | 22.03 |
Minimum of Months | 7.83 | 20.51 | 2.67 | 20.44 | 0.00 | 20.42 |
Maximum of Months | 513.33 | 25.18 | 480.50 | 24.36 | 435.83 | 24.38 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.46 | 429.50 | 20.41 | 429.50 | 20.39 |
February | 454.00 | 21.14 | 244.33 | 20.99 | 244.33 | 20.92 |
March | 481.33 | 21.63 | 116.33 | 21.51 | 112.00 | 21.41 |
April | 357.67 | 22.37 | 47.67 | 22.59 | 4.67 | 22.57 |
May | 180.33 | 23.03 | 212.50 | 23.84 | 3.50 | 23.87 |
June | 79.00 | 23.58 | 356.17 | 24.14 | 15.33 | 24.24 |
July | 38.67 | 23.82 | 429.83 | 24.14 | 12.83 | 24.19 |
August | 116.33 | 23.10 | 332.00 | 23.86 | 11.50 | 23.94 |
September | 256.33 | 22.64 | 146.33 | 23.28 | 3.50 | 23.31 |
October | 451.33 | 22.15 | 23.83 | 22.30 | 0.17 | 22.30 |
November | 486.33 | 21.47 | 92.33 | 21.34 | 92.33 | 21.25 |
December | 497.00 | 20.63 | 384.17 | 20.56 | 384.17 | 20.53 |
Annual Sum or Average | 3900.33 | 21.64 | 2815.00 | 22.04 | 1313.83 | 21.83 |
Minimum of Months | 38.67 | 20.46 | 23.83 | 20.41 | 0.17 | 20.39 |
Maximum of Months | 502.00 | 23.82 | 429.83 | 24.14 | 429.50 | 24.24 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 482.83 | 20.86 | 331.00 | 20.62 | 331.00 | 20.51 |
February | 385.00 | 21.50 | 196.00 | 21.34 | 178.83 | 21.17 |
March | 410.83 | 21.84 | 128.17 | 21.86 | 96.67 | 21.71 |
April | 324.17 | 22.57 | 66.67 | 22.80 | 17.33 | 22.79 |
May | 169.17 | 23.01 | 207.17 | 23.82 | 0.33 | 23.82 |
June | 84.00 | 23.22 | 339.17 | 24.04 | 5.50 | 24.08 |
July | 41.33 | 24.38 | 442.50 | 24.29 | 16.50 | 24.36 |
August | 59.83 | 24.19 | 418.17 | 24.24 | 19.33 | 24.34 |
September | 199.17 | 23.07 | 215.33 | 23.84 | 14.33 | 23.94 |
October | 381.67 | 22.43 | 82.17 | 22.83 | 10.67 | 22.90 |
November | 430.33 | 21.66 | 121.17 | 21.56 | 101.83 | 21.40 |
December | 476.83 | 20.98 | 293.00 | 20.78 | 293.00 | 20.68 |
Annual Sum or Average | 3445.17 | 21.89 | 2840.50 | 22.38 | 1085.33 | 22.16 |
Minimum of Months | 41.33 | 20.86 | 66.67 | 20.62 | 0.33 | 20.51 |
Maximum of Months | 482.83 | 24.38 | 442.50 | 24.29 | 331.00 | 24.36 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.85 | 335.67 | 20.74 | 335.67 | 20.69 |
February | 431.67 | 21.69 | 107.67 | 21.56 | 105.50 | 21.46 |
March | 418.17 | 22.46 | 39.33 | 22.58 | 11.17 | 22.58 |
April | 184.50 | 23.36 | 127.50 | 24.07 | 7.33 | 24.14 |
May | 128.50 | 23.32 | 277.00 | 24.18 | 10.00 | 24.25 |
June | 31.33 | 25.04 | 426.33 | 24.44 | 17.67 | 24.52 |
July | 48.17 | 26.62 | 493.83 | 24.68 | 48.17 | 24.84 |
August | 35.17 | 26.84 | 505.33 | 24.57 | 34.67 | 24.71 |
September | 170.17 | 22.90 | 207.17 | 23.82 | 7.00 | 23.88 |
October | 334.17 | 22.82 | 74.67 | 23.17 | 1.33 | 23.18 |
November | 428.33 | 22.54 | 19.33 | 22.60 | 4.50 | 22.58 |
December | 497.00 | 21.71 | 88.33 | 21.56 | 88.33 | 21.46 |
Annual Sum or Average | 3209.17 | 22.28 | 2702.17 | 22.95 | 671.33 | 22.84 |
Minimum of Months | 31.33 | 20.85 | 19.33 | 20.74 | 1.33 | 20.69 |
Maximum of Months | 502.00 | 26.84 | 505.33 | 24.68 | 335.67 | 24.84 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 19.74 | 502.00 | 19.74 | 502.00 | 19.74 |
February | 454.00 | 20.02 | 439.50 | 20.00 | 439.50 | 20.00 |
March | 514.00 | 20.64 | 377.33 | 20.51 | 377.33 | 20.45 |
April | 479.67 | 21.74 | 129.17 | 21.44 | 129.17 | 21.24 |
May | 240.33 | 23.10 | 134.67 | 23.56 | 0.50 | 23.56 |
June | 70.50 | 23.58 | 288.00 | 24.10 | 7.17 | 24.13 |
July | 55.33 | 25.06 | 458.00 | 24.42 | 40.17 | 24.51 |
August | 72.33 | 23.16 | 355.33 | 23.95 | 0.33 | 23.95 |
September | 325.33 | 22.84 | 62.83 | 23.05 | 3.00 | 23.06 |
October | 498.33 | 21.60 | 91.67 | 21.39 | 91.67 | 21.23 |
November | 489.00 | 20.39 | 354.00 | 20.23 | 354.00 | 20.16 |
December | 497.00 | 19.80 | 495.50 | 19.80 | 495.50 | 19.80 |
Annual Sum or Average | 4197.83 | 21.04 | 3688.00 | 21.25 | 2440.33 | 20.97 |
Minimum of Months | 55.33 | 19.74 | 62.83 | 19.74 | 0.33 | 19.74 |
Maximum of Months | 514.00 | 25.06 | 502.00 | 24.42 | 502.00 | 24.51 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 427.00 | 19.63 | 427.00 | 19.63 | 427.00 | 19.63 |
February | 385.00 | 19.98 | 353.67 | 19.93 | 353.67 | 19.92 |
March | 426.17 | 20.82 | 267.00 | 20.66 | 267.00 | 20.58 |
April | 340.83 | 21.54 | 96.17 | 21.43 | 78.00 | 21.24 |
May | 211.83 | 22.57 | 155.33 | 23.46 | 2.83 | 23.49 |
June | 109.17 | 23.36 | 267.67 | 24.06 | 20.50 | 24.20 |
July | 70.83 | 24.51 | 347.83 | 24.40 | 36.67 | 24.56 |
August | 155.33 | 22.76 | 234.83 | 23.68 | 13.00 | 23.78 |
September | 285.83 | 22.07 | 70.50 | 22.55 | 1.33 | 22.56 |
October | 407.50 | 21.19 | 87.50 | 21.14 | 75.50 | 21.02 |
November | 417.00 | 20.27 | 294.50 | 20.12 | 294.50 | 20.06 |
December | 422.00 | 19.67 | 421.17 | 19.66 | 421.17 | 19.66 |
Annual Sum or Average | 3658.50 | 20.93 | 3023.17 | 21.21 | 1991.17 | 20.96 |
Minimum of Months | 70.83 | 19.63 | 70.50 | 19.63 | 1.33 | 19.63 |
Maximum of Months | 427.00 | 24.51 | 427.00 | 24.40 | 427.00 | 24.56 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 486.50 | 20.20 | 402.17 | 20.00 | 402.17 | 19.92 |
February | 405.83 | 20.82 | 267.17 | 20.58 | 257.83 | 20.43 |
March | 424.67 | 21.27 | 233.83 | 21.23 | 202.50 | 21.07 |
April | 359.17 | 21.88 | 122.83 | 21.95 | 75.50 | 21.78 |
May | 210.83 | 22.70 | 184.17 | 23.52 | 0.67 | 23.53 |
June | 135.00 | 22.94 | 288.67 | 23.83 | 9.50 | 23.87 |
July | 88.33 | 24.31 | 405.83 | 24.36 | 41.00 | 24.49 |
August | 124.17 | 23.34 | 355.33 | 24.04 | 19.67 | 24.15 |
September | 253.17 | 22.68 | 179.17 | 23.47 | 16.67 | 23.60 |
October | 413.50 | 21.77 | 126.00 | 22.04 | 65.00 | 21.97 |
November | 450.50 | 20.82 | 234.67 | 20.59 | 225.67 | 20.45 |
December | 493.33 | 20.25 | 418.00 | 20.09 | 418.00 | 20.03 |
Annual Sum or Average | 3845.00 | 21.38 | 3217.83 | 21.74 | 1734.17 | 21.48 |
Minimum of Months | 88.33 | 20.20 | 122.83 | 20.00 | 0.67 | 19.92 |
Maximum of Months | 493.33 | 24.31 | 418.00 | 24.36 | 418.00 | 24.49 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 19.92 | 479.50 | 19.89 | 479.50 | 19.87 |
February | 452.17 | 20.36 | 363.33 | 20.24 | 363.33 | 20.20 |
March | 491.83 | 20.91 | 272.50 | 20.76 | 267.33 | 20.67 |
April | 413.67 | 21.61 | 115.83 | 21.60 | 83.50 | 21.45 |
May | 243.83 | 22.61 | 189.83 | 23.44 | 6.17 | 23.49 |
June | 138.00 | 22.77 | 300.33 | 23.79 | 9.83 | 23.85 |
July | 82.00 | 24.55 | 420.33 | 24.42 | 42.17 | 24.57 |
August | 144.17 | 22.87 | 318.17 | 23.82 | 14.67 | 23.91 |
September | 340.00 | 22.19 | 95.83 | 22.66 | 4.17 | 22.70 |
October | 467.83 | 21.33 | 79.50 | 21.29 | 65.00 | 21.19 |
November | 489.00 | 20.52 | 294.67 | 20.35 | 294.67 | 20.28 |
December | 497.00 | 19.97 | 477.17 | 19.95 | 477.17 | 19.94 |
Annual Sum or Average | 4261.50 | 21.09 | 3407.00 | 21.40 | 2107.50 | 21.16 |
Minimum of Months | 82.00 | 19.92 | 79.50 | 19.89 | 4.17 | 19.87 |
Maximum of Months | 502.00 | 24.55 | 479.50 | 24.42 | 479.50 | 24.57 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 19.56 | 502.00 | 19.56 | 502.00 | 19.56 |
February | 454.00 | 19.78 | 452.33 | 19.78 | 452.33 | 19.78 |
March | 514.00 | 20.22 | 460.50 | 20.17 | 460.50 | 20.15 |
April | 483.00 | 20.87 | 258.00 | 20.58 | 258.00 | 20.44 |
May | 306.50 | 22.34 | 148.83 | 22.78 | 26.67 | 22.66 |
June | 134.33 | 22.82 | 257.67 | 23.71 | 6.67 | 23.73 |
July | 84.67 | 24.02 | 406.83 | 24.24 | 40.50 | 24.34 |
August | 162.50 | 22.68 | 277.67 | 23.54 | 0.50 | 23.54 |
September | 412.00 | 22.06 | 40.00 | 22.15 | 9.67 | 22.12 |
October | 502.00 | 20.63 | 219.50 | 20.37 | 219.50 | 20.23 |
November | 489.00 | 19.90 | 428.67 | 19.82 | 428.67 | 19.79 |
December | 497.00 | 19.60 | 497.00 | 19.60 | 497.00 | 19.60 |
Annual Sum or Average | 4541.00 | 20.66 | 3949.00 | 20.82 | 2902.00 | 20.58 |
Minimum of Months | 84.67 | 19.56 | 40.00 | 19.56 | 0.50 | 19.56 |
Maximum of Months | 514.00 | 24.02 | 502.00 | 24.24 | 502.00 | 24.34 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 19.71 | 502.00 | 19.71 | 502.00 | 19.71 |
February | 454.00 | 19.88 | 428.67 | 19.84 | 428.67 | 19.83 |
March | 514.00 | 20.51 | 395.50 | 20.36 | 395.50 | 20.31 |
April | 423.83 | 21.21 | 157.67 | 20.89 | 150.83 | 20.67 |
May | 244.83 | 22.19 | 182.83 | 23.13 | 5.67 | 23.10 |
June | 135.00 | 23.07 | 321.00 | 23.90 | 21.00 | 24.01 |
July | 93.83 | 24.03 | 410.67 | 24.26 | 40.83 | 24.41 |
August | 188.83 | 22.54 | 286.50 | 23.54 | 11.67 | 23.62 |
September | 349.67 | 21.80 | 82.83 | 22.22 | 7.00 | 22.20 |
October | 489.00 | 20.77 | 197.67 | 20.55 | 191.00 | 20.40 |
November | 489.00 | 19.93 | 404.33 | 19.83 | 404.33 | 19.79 |
December | 497.00 | 19.71 | 497.00 | 19.71 | 497.00 | 19.71 |
Annual Sum or Average | 4381.00 | 20.73 | 3866.67 | 21.00 | 2655.50 | 20.76 |
Minimum of Months | 93.83 | 19.71 | 82.83 | 19.71 | 5.67 | 19.71 |
Maximum of Months | 514.00 | 24.03 | 502.00 | 24.26 | 502.00 | 24.41 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 494.50 | 19.93 | 431.33 | 19.78 | 431.33 | 19.72 |
February | 425.50 | 20.35 | 322.17 | 20.12 | 316.17 | 20.01 |
March | 456.83 | 20.86 | 312.67 | 20.70 | 296.00 | 20.56 |
April | 393.17 | 21.34 | 195.67 | 21.17 | 163.83 | 20.95 |
May | 256.17 | 22.28 | 182.67 | 23.00 | 18.83 | 22.90 |
June | 170.17 | 22.53 | 271.33 | 23.55 | 11.00 | 23.60 |
July | 118.00 | 23.74 | 383.00 | 24.21 | 45.00 | 24.36 |
August | 167.00 | 22.88 | 314.33 | 23.79 | 18.33 | 23.90 |
September | 301.83 | 22.16 | 151.50 | 22.95 | 14.33 | 23.03 |
October | 430.33 | 21.01 | 211.17 | 21.08 | 157.83 | 20.89 |
November | 461.50 | 20.19 | 321.67 | 19.97 | 320.67 | 19.87 |
December | 497.00 | 19.90 | 453.00 | 19.79 | 453.00 | 19.76 |
Annual Sum or Average | 4172.00 | 20.98 | 3550.50 | 21.26 | 2246.33 | 20.99 |
Minimum of Months | 118.00 | 19.90 | 151.50 | 19.78 | 11.00 | 19.72 |
Maximum of Months | 497.00 | 23.74 | 453.00 | 24.21 | 453.00 | 24.36 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 19.75 | 489.50 | 19.74 | 489.50 | 19.73 |
February | 454.00 | 20.05 | 398.67 | 19.95 | 398.67 | 19.92 |
March | 495.83 | 20.55 | 360.33 | 20.41 | 357.50 | 20.34 |
April | 428.00 | 21.10 | 197.17 | 20.95 | 171.17 | 20.76 |
May | 273.67 | 22.20 | 183.83 | 23.02 | 16.67 | 23.02 |
June | 172.33 | 22.43 | 271.50 | 23.54 | 10.33 | 23.59 |
July | 109.00 | 23.96 | 387.33 | 24.30 | 44.83 | 24.46 |
August | 195.83 | 22.58 | 282.17 | 23.55 | 14.67 | 23.64 |
September | 376.17 | 21.85 | 79.83 | 22.28 | 4.50 | 22.31 |
October | 475.33 | 20.83 | 167.17 | 20.66 | 155.67 | 20.50 |
November | 489.00 | 20.06 | 376.67 | 19.92 | 376.67 | 19.86 |
December | 497.00 | 19.77 | 493.67 | 19.77 | 493.67 | 19.77 |
Annual Sum or Average | 4468.17 | 20.81 | 3687.83 | 21.05 | 2533.83 | 20.82 |
Minimum of Months | 109.00 | 19.75 | 79.83 | 19.74 | 4.50 | 19.73 |
Maximum of Months | 502.00 | 23.96 | 493.67 | 24.30 | 493.67 | 24.46 |
Report: ComfortReportSimple55Monthly
For: GROUNDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: DATACENTER_BOT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 6.50 | 25.93 | 274.17 | 26.97 | 0.00 | 26.97 |
February | 0.00 | 0.00 | 432.50 | 27.00 | 0.00 | 27.00 |
March | 7.67 | 27.00 | 514.00 | 27.00 | 7.67 | 27.00 |
April | 24.17 | 27.11 | 485.00 | 27.01 | 24.17 | 27.02 |
May | 26.83 | 27.00 | 508.00 | 27.00 | 26.83 | 27.00 |
June | 110.17 | 27.00 | 496.00 | 27.00 | 110.17 | 27.00 |
July | 266.33 | 27.00 | 497.00 | 27.00 | 266.33 | 27.00 |
August | 341.17 | 27.00 | 514.00 | 27.00 | 341.17 | 27.00 |
September | 18.83 | 27.00 | 485.00 | 27.00 | 18.83 | 27.00 |
October | 11.00 | 27.00 | 502.00 | 27.00 | 11.00 | 27.00 |
November | 0.00 | 0.00 | 489.00 | 27.00 | 0.00 | 27.00 |
December | 0.00 | 0.00 | 497.00 | 27.00 | 0.00 | 27.00 |
Annual Sum or Average | 812.67 | 27.00 | 5693.67 | 27.00 | 806.17 | 27.00 |
Minimum of Months | 0.00 | 0.00 | 274.17 | 26.97 | 0.00 | 26.97 |
Maximum of Months | 341.17 | 27.11 | 514.00 | 27.01 | 341.17 | 27.02 |
Report: ComfortReportSimple55Monthly
For: DATACENTER_MID_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 244.50 | 25.34 | 68.83 | 25.56 | 8.83 | 25.47 |
February | 31.33 | 27.00 | 162.17 | 27.00 | 0.00 | 27.00 |
March | 0.17 | 27.00 | 372.83 | 27.00 | 0.17 | 27.00 |
April | 4.50 | 27.08 | 477.33 | 27.00 | 4.50 | 27.00 |
May | 14.17 | 27.00 | 508.00 | 27.00 | 14.17 | 27.00 |
June | 29.83 | 27.00 | 496.00 | 27.00 | 29.83 | 27.00 |
July | 70.50 | 27.00 | 497.00 | 27.00 | 70.50 | 27.00 |
August | 62.00 | 27.00 | 514.00 | 27.00 | 62.00 | 27.00 |
September | 10.33 | 27.00 | 485.00 | 27.00 | 10.33 | 27.00 |
October | 2.33 | 27.00 | 502.00 | 27.00 | 2.33 | 27.00 |
November | 12.67 | 27.00 | 357.67 | 27.00 | 0.00 | 27.00 |
December | 46.50 | 27.00 | 157.00 | 27.00 | 0.00 | 27.00 |
Annual Sum or Average | 528.83 | 26.23 | 4597.83 | 26.91 | 202.67 | 26.91 |
Minimum of Months | 0.17 | 25.34 | 68.83 | 25.56 | 0.00 | 25.47 |
Maximum of Months | 244.50 | 27.08 | 514.00 | 27.00 | 70.50 | 27.00 |
Report: ComfortReportSimple55Monthly
For: DATACENTER_TOP_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 386.00 | 24.52 | 102.50 | 24.31 | 74.83 | 24.03 |
February | 96.50 | 26.95 | 91.83 | 26.97 | 0.00 | 26.97 |
March | 44.50 | 27.00 | 242.50 | 27.00 | 0.00 | 27.00 |
April | 8.50 | 27.00 | 401.00 | 27.00 | 4.00 | 27.00 |
May | 23.83 | 27.00 | 502.33 | 27.00 | 23.83 | 27.00 |
June | 49.67 | 27.00 | 496.00 | 27.00 | 49.67 | 27.00 |
July | 101.67 | 27.00 | 497.00 | 27.00 | 101.67 | 27.00 |
August | 78.17 | 27.00 | 514.00 | 27.00 | 78.17 | 27.00 |
September | 10.67 | 27.00 | 485.00 | 27.00 | 10.67 | 27.00 |
October | 2.50 | 27.00 | 446.67 | 27.00 | 2.50 | 27.00 |
November | 65.17 | 27.00 | 230.00 | 27.00 | 0.00 | 27.00 |
December | 104.17 | 27.00 | 78.83 | 27.00 | 0.00 | 27.00 |
Annual Sum or Average | 971.33 | 26.01 | 4087.67 | 26.74 | 345.33 | 26.69 |
Minimum of Months | 2.50 | 24.52 | 78.83 | 24.31 | 0.00 | 24.03 |
Maximum of Months | 386.00 | 27.00 | 514.00 | 27.00 | 101.67 | 27.00 |
Report: ComfortReportSimple55Monthly
For: DATACENTER_BASEMENT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 55.00 | 27.00 | 502.00 | 27.00 | 55.00 | 27.00 |
February | 454.00 | 27.00 | 454.00 | 27.00 | 454.00 | 27.00 |
March | 514.00 | 27.01 | 514.00 | 27.01 | 514.00 | 27.01 |
April | 485.00 | 27.02 | 485.00 | 27.02 | 485.00 | 27.02 |
May | 503.50 | 27.00 | 508.00 | 27.00 | 503.50 | 27.00 |
June | 496.00 | 27.00 | 496.00 | 27.00 | 496.00 | 27.00 |
July | 497.00 | 27.00 | 497.00 | 27.00 | 497.00 | 27.00 |
August | 514.00 | 27.18 | 514.00 | 27.18 | 514.00 | 27.18 |
September | 485.00 | 27.00 | 485.00 | 27.00 | 485.00 | 27.00 |
October | 502.00 | 27.00 | 502.00 | 27.00 | 502.00 | 27.00 |
November | 489.00 | 27.01 | 489.00 | 27.01 | 489.00 | 27.01 |
December | 497.00 | 27.01 | 497.00 | 27.01 | 497.00 | 27.01 |
Annual Sum or Average | 5491.50 | 27.02 | 5943.00 | 27.02 | 5491.50 | 27.02 |
Minimum of Months | 55.00 | 27.00 | 454.00 | 27.00 | 55.00 | 27.00 |
Maximum of Months | 514.00 | 27.18 | 514.00 | 27.18 | 514.00 | 27.18 |
Report: OccupantComfortDataSummaryMonthly
For: DATACENTER_BOT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 26.96537 | 11.14256 | 0.55896 | 11.70445 |
February | 454.00000 | 27.00000 | 11.51495 | 0.65955 | 14.29399 |
March | 514.00000 | 27.00000 | 14.98279 | 0.76228 | 17.39425 |
April | 485.00000 | 27.00616 | 18.04402 | 0.87298 | 21.19025 |
May | 508.00000 | 27.00026 | 29.14821 | 0.23303 | 6.35987 |
June | 496.00000 | 27.00089 | 34.76194 | 0.34144 | 7.56558 |
July | 497.00000 | 27.00070 | 36.44913 | 0.41379 | 8.65729 |
August | 514.00000 | 27.00031 | 35.78367 | 0.43796 | 9.08879 |
September | 485.00000 | 27.00033 | 32.77475 | 0.23839 | 6.34377 |
October | 502.00000 | 27.00003 | 27.20600 | 0.86328 | 20.83657 |
November | 489.00000 | 27.00002 | 17.95455 | 0.78029 | 17.98449 |
December | 497.00000 | 27.00000 | 11.51929 | 0.69986 | 15.41044 |
Annual Sum or Average | 5943.00000 | 26.99779 | 23.53847 | 0.57077 | 13.04573 |
Minimum of Months | 454.00000 | 26.96537 | 11.14256 | 0.23303 | 6.34377 |
Maximum of Months | 514.00000 | 27.00616 | 36.44913 | 0.87298 | 21.19025 |
Report: OccupantComfortDataSummaryMonthly
For: DATACENTER_MID_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 26.11624 | 10.99219 | 0.27442 | 8.03302 |
February | 454.00000 | 27.00000 | 11.50119 | 0.50694 | 10.60384 |
March | 514.00000 | 27.00000 | 14.96701 | 0.60997 | 13.04967 |
April | 485.00000 | 27.00200 | 18.03366 | 0.72090 | 16.14012 |
May | 508.00000 | 27.00024 | 29.15192 | 0.15805 | 5.86715 |
June | 496.00000 | 27.00088 | 34.79004 | 0.24948 | 6.51927 |
July | 497.00000 | 27.00077 | 36.46189 | 0.31348 | 7.17872 |
August | 514.00000 | 27.00036 | 35.78535 | 0.29556 | 6.98173 |
September | 485.00000 | 27.00022 | 32.83466 | 0.13991 | 5.62826 |
October | 502.00000 | 27.00003 | 27.18597 | 0.74339 | 16.79874 |
November | 489.00000 | 27.00002 | 17.92420 | 0.60740 | 12.99940 |
December | 497.00000 | 27.00000 | 11.49978 | 0.49252 | 10.27744 |
Annual Sum or Average | 5943.00000 | 26.92572 | 23.52545 | 0.42498 | 9.99158 |
Minimum of Months | 454.00000 | 26.11624 | 10.99219 | 0.13991 | 5.62826 |
Maximum of Months | 514.00000 | 27.00200 | 36.46189 | 0.74339 | 16.79874 |
Report: OccupantComfortDataSummaryMonthly
For: DATACENTER_TOP_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 25.04120 | 11.01425 | 0.01511 | 8.16304 |
February | 454.00000 | 26.98844 | 11.50500 | 0.43460 | 9.32398 |
March | 514.00000 | 27.00000 | 14.97230 | 0.53371 | 11.33960 |
April | 485.00000 | 27.00081 | 18.03878 | 0.65584 | 14.41487 |
May | 508.00000 | 26.99948 | 29.15566 | 0.12500 | 5.91921 |
June | 496.00000 | 27.00087 | 34.80653 | 0.23690 | 6.54895 |
July | 497.00000 | 27.00077 | 36.46714 | 0.30953 | 7.23395 |
August | 514.00000 | 27.00038 | 35.79660 | 0.28007 | 6.89614 |
September | 485.00000 | 27.00020 | 32.89659 | 0.09004 | 5.52804 |
October | 502.00000 | 27.00003 | 27.20290 | 0.67099 | 14.75529 |
November | 489.00000 | 27.00002 | 17.93786 | 0.52562 | 11.18409 |
December | 497.00000 | 27.00000 | 11.50626 | 0.42553 | 9.09337 |
Annual Sum or Average | 5943.00000 | 26.83387 | 23.53974 | 0.35758 | 9.19107 |
Minimum of Months | 454.00000 | 25.04120 | 11.01425 | 0.01511 | 5.52804 |
Maximum of Months | 514.00000 | 27.00087 | 36.46714 | 0.67099 | 14.75529 |
Report: OccupantComfortDataSummaryMonthly
For: DATACENTER_BASEMENT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 27.00021 | 30.21367 | 0.97164 | 24.97969 |
February | 454.00000 | 27.00211 | 30.13591 | 1.17179 | 33.89408 |
March | 514.00000 | 27.00778 | 30.07818 | 1.33067 | 41.86325 |
April | 485.00000 | 27.02196 | 30.17683 | 1.49090 | 50.40768 |
May | 508.00000 | 27.00070 | 32.69348 | 0.50185 | 10.32774 |
June | 496.00000 | 27.00145 | 35.06449 | 0.75402 | 17.02064 |
July | 497.00000 | 27.00069 | 36.20767 | 0.98359 | 25.45816 |
August | 514.00000 | 27.17563 | 35.57256 | 1.22964 | 36.85815 |
September | 485.00000 | 27.00076 | 33.42433 | 0.55720 | 11.57408 |
October | 502.00000 | 27.00236 | 31.04690 | 1.24943 | 37.70640 |
November | 489.00000 | 27.00697 | 30.48778 | 1.36828 | 43.83503 |
December | 497.00000 | 27.01351 | 30.15658 | 1.46697 | 49.11186 |
Annual Sum or Average | 5943.00000 | 27.02004 | 32.12475 | 1.08906 | 31.89730 |
Minimum of Months | 454.00000 | 27.00021 | 30.07818 | 0.50185 | 10.32774 |
Maximum of Months | 514.00000 | 27.17563 | 36.20767 | 1.49090 | 50.40768 |
Report: OccupantComfortDataSummaryMonthly
For: BASEMENT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 23.75778 | 13.85348 | 0.08729 | 6.01902 |
February | 454.00000 | 24.25450 | 12.15498 | 0.20847 | 6.18507 |
March | 514.00000 | 24.31554 | 14.79512 | 0.25224 | 6.50314 |
April | 485.00000 | 24.43994 | 16.62661 | 0.30469 | 7.31484 |
May | 508.00000 | 24.46427 | 31.88496 | -0.4312 | 9.82055 |
June | 496.00000 | 24.43302 | 47.03357 | -0.3205 | 8.11893 |
July | 497.00000 | 24.60072 | 55.04350 | -0.2026 | 7.28308 |
August | 514.00000 | 24.47826 | 52.69274 | -0.2467 | 7.23122 |
September | 485.00000 | 24.53837 | 36.85442 | -0.3542 | 8.86258 |
October | 502.00000 | 24.55698 | 26.88099 | 0.41733 | 9.32511 |
November | 489.00000 | 24.51544 | 17.26640 | 0.32781 | 7.68347 |
December | 497.00000 | 24.27306 | 12.11115 | 0.21992 | 6.42399 |
Annual Sum or Average | 5943.00000 | 24.38583 | 28.25836 | 0.01981 | 7.57223 |
Minimum of Months | 454.00000 | 23.75778 | 12.11115 | -0.4312 | 6.01902 |
Maximum of Months | 514.00000 | 24.60072 | 55.04350 | 0.41733 | 9.82055 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 23.29216 | 13.40987 | -0.0380 | 5.98534 |
February | 454.00000 | 23.90845 | 14.04797 | 0.13446 | 5.61169 |
March | 514.00000 | 24.11925 | 16.39288 | 0.22494 | 6.21351 |
April | 485.00000 | 24.31779 | 17.83595 | 0.30608 | 7.20890 |
May | 508.00000 | 24.29744 | 32.29529 | -0.4543 | 10.01471 |
June | 496.00000 | 24.24767 | 45.36170 | -0.3563 | 8.09869 |
July | 497.00000 | 24.29292 | 51.83501 | -0.2852 | 7.04849 |
August | 514.00000 | 24.23796 | 51.11694 | -0.3014 | 7.16442 |
September | 485.00000 | 24.30908 | 38.18400 | -0.4119 | 9.19439 |
October | 502.00000 | 24.31434 | 28.67333 | 0.37121 | 8.17081 |
November | 489.00000 | 24.28976 | 19.51411 | 0.28261 | 6.95947 |
December | 497.00000 | 24.01766 | 14.09470 | 0.15991 | 5.74163 |
Annual Sum or Average | 5943.00000 | 24.13773 | 28.70405 | -0.0326 | 7.29434 |
Minimum of Months | 454.00000 | 23.29216 | 13.40987 | -0.4543 | 5.61169 |
Maximum of Months | 514.00000 | 24.31779 | 51.83501 | 0.37121 | 10.01471 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 21.43139 | 14.10197 | -0.5048 | 12.63031 |
February | 454.00000 | 22.17919 | 15.84676 | -0.3030 | 8.46973 |
March | 514.00000 | 23.04034 | 18.96393 | -0.0616 | 6.05516 |
April | 485.00000 | 23.73709 | 19.83196 | 0.13362 | 5.75750 |
May | 508.00000 | 24.16934 | 32.96096 | -0.5253 | 11.67441 |
June | 496.00000 | 24.14313 | 46.03048 | -0.4233 | 9.16603 |
July | 497.00000 | 24.26807 | 52.52950 | -0.3330 | 7.73620 |
August | 514.00000 | 24.14033 | 52.30789 | -0.3796 | 8.36621 |
September | 485.00000 | 24.08110 | 39.19090 | -0.5195 | 11.19645 |
October | 502.00000 | 23.69580 | 31.02789 | 0.19693 | 6.21079 |
November | 489.00000 | 22.97501 | 22.47036 | -0.0614 | 6.48249 |
December | 497.00000 | 21.71391 | 15.90957 | -0.4191 | 10.45916 |
Annual Sum or Average | 5943.00000 | 23.30586 | 30.23505 | -0.2670 | 8.68732 |
Minimum of Months | 454.00000 | 21.43139 | 14.10197 | -0.5253 | 5.75750 |
Maximum of Months | 514.00000 | 24.26807 | 52.52950 | 0.19693 | 12.63031 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.42650 | 14.60309 | -0.7861 | 20.99302 |
February | 454.00000 | 20.84949 | 16.46566 | -0.6552 | 16.95084 |
March | 514.00000 | 21.59269 | 20.31135 | -0.4333 | 11.52120 |
April | 485.00000 | 22.62002 | 21.52979 | -0.1481 | 7.61340 |
May | 508.00000 | 23.87914 | 33.55295 | -0.6343 | 15.47479 |
June | 496.00000 | 23.99731 | 46.58732 | -0.4697 | 10.42922 |
July | 497.00000 | 24.20783 | 52.75563 | -0.3487 | 8.14454 |
August | 514.00000 | 24.03967 | 52.89218 | -0.4161 | 9.13778 |
September | 485.00000 | 23.66614 | 40.70791 | -0.6798 | 15.91853 |
October | 502.00000 | 22.41651 | 34.59401 | -0.1240 | 7.31098 |
November | 489.00000 | 21.32073 | 24.06393 | -0.4790 | 13.31955 |
December | 497.00000 | 20.52075 | 16.53029 | -0.7440 | 19.72057 |
Annual Sum or Average | 5943.00000 | 22.47449 | 31.35434 | -0.4922 | 13.01233 |
Minimum of Months | 454.00000 | 20.42650 | 14.60309 | -0.7861 | 7.31098 |
Maximum of Months | 514.00000 | 24.20783 | 52.89218 | -0.1240 | 20.99302 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.50778 | 13.19911 | -0.7555 | 18.55483 |
February | 454.00000 | 21.16193 | 14.28507 | -0.5465 | 12.33587 |
March | 514.00000 | 21.98602 | 17.15845 | -0.3097 | 8.37557 |
April | 485.00000 | 23.32110 | 18.11965 | 0.03735 | 5.85165 |
May | 508.00000 | 24.07262 | 31.74261 | -0.5377 | 12.33349 |
June | 496.00000 | 24.22157 | 44.58903 | -0.3480 | 8.10890 |
July | 497.00000 | 24.33319 | 51.13731 | -0.2491 | 6.90927 |
August | 514.00000 | 24.17142 | 50.69910 | -0.3343 | 7.68712 |
September | 485.00000 | 23.86544 | 38.42786 | -0.5942 | 13.48826 |
October | 502.00000 | 23.20630 | 28.86698 | 0.06920 | 5.80283 |
November | 489.00000 | 22.18544 | 20.22223 | -0.2419 | 7.61727 |
December | 497.00000 | 20.84837 | 14.41585 | -0.6225 | 14.60570 |
Annual Sum or Average | 5943.00000 | 22.83511 | 28.70889 | -0.3687 | 10.12440 |
Minimum of Months | 454.00000 | 20.50778 | 13.19911 | -0.7555 | 5.80283 |
Maximum of Months | 514.00000 | 24.33319 | 51.13731 | 0.06920 | 18.55483 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.46327 | 12.35383 | -0.7566 | 18.42746 |
February | 454.00000 | 21.13920 | 13.50446 | -0.5326 | 11.97871 |
March | 514.00000 | 21.80199 | 16.49483 | -0.3168 | 8.94568 |
April | 485.00000 | 22.85852 | 17.95838 | 0.00193 | 7.01791 |
May | 508.00000 | 23.83622 | 31.81189 | -0.5212 | 13.40733 |
June | 496.00000 | 23.98950 | 45.02865 | -0.3288 | 9.29906 |
July | 497.00000 | 24.01448 | 51.80923 | -0.2568 | 7.84960 |
August | 514.00000 | 23.71013 | 51.94018 | -0.4094 | 10.62550 |
September | 485.00000 | 23.34456 | 39.15390 | -0.6744 | 17.50514 |
October | 502.00000 | 22.37762 | 29.36404 | -0.0765 | 6.59316 |
November | 489.00000 | 21.48081 | 20.22182 | -0.3817 | 9.07445 |
December | 497.00000 | 20.62691 | 13.78554 | -0.6793 | 15.78795 |
Annual Sum or Average | 5943.00000 | 22.48082 | 28.76193 | -0.4104 | 11.36808 |
Minimum of Months | 454.00000 | 20.46327 | 12.35383 | -0.7566 | 6.59316 |
Maximum of Months | 514.00000 | 24.01448 | 51.94018 | 0.00193 | 18.42746 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.97933 | 12.26943 | -0.6038 | 16.06008 |
February | 454.00000 | 21.92569 | 13.03301 | -0.3233 | 10.94364 |
March | 514.00000 | 22.35052 | 16.07947 | -0.1798 | 9.10281 |
April | 485.00000 | 23.11341 | 17.68013 | 0.05520 | 7.50646 |
May | 508.00000 | 23.86208 | 31.74104 | -0.5380 | 13.67629 |
June | 496.00000 | 23.97822 | 45.05353 | -0.3815 | 9.61428 |
July | 497.00000 | 24.16869 | 51.37211 | -0.2414 | 7.57916 |
August | 514.00000 | 24.06673 | 50.79400 | -0.2871 | 8.48107 |
September | 485.00000 | 23.76126 | 38.21989 | -0.5282 | 14.54559 |
October | 502.00000 | 22.88438 | 28.56294 | 0.04753 | 7.87026 |
November | 489.00000 | 21.97577 | 19.79841 | -0.2600 | 9.17903 |
December | 497.00000 | 21.10953 | 13.74455 | -0.5486 | 13.90335 |
Annual Sum or Average | 5943.00000 | 22.85564 | 28.33833 | -0.3160 | 10.70106 |
Minimum of Months | 454.00000 | 20.97933 | 12.26943 | -0.6038 | 7.50646 |
Maximum of Months | 514.00000 | 24.16869 | 51.37211 | 0.05520 | 16.06008 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.84808 | 11.94706 | -0.6220 | 14.36567 |
February | 454.00000 | 21.82440 | 12.79654 | -0.3230 | 8.83982 |
March | 514.00000 | 22.78633 | 15.39126 | -0.0331 | 6.83974 |
April | 485.00000 | 24.03486 | 16.55286 | 0.32701 | 8.53061 |
May | 508.00000 | 24.07822 | 31.20267 | -0.3858 | 10.83744 |
June | 496.00000 | 24.26671 | 44.14273 | -0.1771 | 7.25882 |
July | 497.00000 | 24.48499 | 50.27213 | -0.0123 | 6.73507 |
August | 514.00000 | 24.39795 | 49.60058 | -0.0583 | 6.58910 |
September | 485.00000 | 23.75418 | 38.03401 | -0.4965 | 12.94530 |
October | 502.00000 | 23.32130 | 27.63806 | 0.17930 | 6.86391 |
November | 489.00000 | 22.76061 | 18.68737 | -0.0412 | 6.31774 |
December | 497.00000 | 21.70765 | 12.86406 | -0.3483 | 8.70535 |
Annual Sum or Average | 5943.00000 | 23.19829 | 27.56594 | -0.1651 | 8.72587 |
Minimum of Months | 454.00000 | 20.84808 | 11.94706 | -0.6220 | 6.31774 |
Maximum of Months | 514.00000 | 24.48499 | 50.27213 | 0.32701 | 14.36567 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 19.73609 | 13.16657 | -1.0437 | 30.21261 |
February | 454.00000 | 20.02182 | 15.28862 | -0.9082 | 24.61089 |
March | 514.00000 | 20.64459 | 18.89836 | -0.6861 | 16.78438 |
April | 485.00000 | 21.76197 | 20.17395 | -0.3469 | 9.62879 |
May | 508.00000 | 23.68621 | 32.49241 | -0.6861 | 17.41458 |
June | 496.00000 | 24.06303 | 45.25794 | -0.4279 | 9.68190 |
July | 497.00000 | 24.28650 | 52.14036 | -0.2945 | 7.62695 |
August | 514.00000 | 23.93108 | 52.16435 | -0.4524 | 9.95860 |
September | 485.00000 | 23.22928 | 40.24030 | -0.8255 | 21.21717 |
October | 502.00000 | 21.61825 | 31.50405 | -0.3176 | 8.63653 |
November | 489.00000 | 20.39220 | 22.49383 | -0.7160 | 18.36177 |
December | 497.00000 | 19.80409 | 15.17395 | -0.9975 | 28.37725 |
Annual Sum or Average | 5943.00000 | 21.94769 | 30.05243 | -0.6398 | 16.81030 |
Minimum of Months | 454.00000 | 19.73609 | 13.16657 | -1.0437 | 7.62695 |
Maximum of Months | 514.00000 | 24.28650 | 52.16435 | -0.2945 | 30.21261 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 427.00000 | 19.63497 | 12.14101 | -1.0488 | 30.61340 |
February | 385.00000 | 19.98108 | 14.17735 | -0.8855 | 23.82045 |
March | 433.00000 | 20.87069 | 17.43958 | -0.5985 | 14.55687 |
April | 410.00000 | 22.01044 | 18.76447 | -0.2284 | 9.43562 |
May | 430.00000 | 23.49551 | 32.01771 | -0.6510 | 18.27753 |
June | 418.00000 | 23.88199 | 45.40719 | -0.3797 | 11.20972 |
July | 422.00000 | 24.13691 | 52.13783 | -0.2370 | 8.56178 |
August | 433.00000 | 23.54211 | 52.80274 | -0.4833 | 13.24323 |
September | 410.00000 | 22.69098 | 40.65986 | -0.9088 | 26.26306 |
October | 427.00000 | 21.35623 | 30.53998 | -0.3533 | 9.50604 |
November | 417.00000 | 20.26530 | 21.19049 | -0.7372 | 18.75527 |
December | 422.00000 | 19.66595 | 14.16477 | -1.0172 | 29.33358 |
Annual Sum or Average | 5034.00000 | 21.80681 | 29.40523 | -0.6257 | 17.74604 |
Minimum of Months | 385.00000 | 19.63497 | 12.14101 | -1.0488 | 8.56178 |
Maximum of Months | 433.00000 | 24.13691 | 52.80274 | -0.2284 | 30.61340 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.31480 | 12.22499 | -0.8067 | 23.42931 |
February | 454.00000 | 21.17019 | 13.72342 | -0.5282 | 16.02873 |
March | 514.00000 | 21.82037 | 17.11770 | -0.3288 | 12.01534 |
April | 485.00000 | 22.48120 | 18.58850 | -0.1025 | 9.21082 |
May | 508.00000 | 23.61823 | 32.17628 | -0.6219 | 16.75151 |
June | 496.00000 | 23.78385 | 45.70687 | -0.4571 | 11.71575 |
July | 497.00000 | 24.13870 | 52.18606 | -0.2680 | 8.51304 |
August | 514.00000 | 23.86693 | 51.94593 | -0.3691 | 10.57777 |
September | 485.00000 | 23.41029 | 39.11304 | -0.6430 | 18.97118 |
October | 502.00000 | 22.22423 | 29.58018 | -0.1136 | 9.44307 |
November | 489.00000 | 21.07836 | 21.14883 | -0.5002 | 14.30245 |
December | 497.00000 | 20.27409 | 14.34242 | -0.8150 | 22.53948 |
Annual Sum or Average | 5943.00000 | 22.35939 | 29.13060 | -0.4623 | 14.43848 |
Minimum of Months | 454.00000 | 20.27409 | 12.22499 | -0.8150 | 8.51304 |
Maximum of Months | 514.00000 | 24.13870 | 52.18606 | -0.1025 | 23.42931 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 19.91785 | 12.20123 | -0.9616 | 26.99068 |
February | 454.00000 | 20.37185 | 14.13432 | -0.7722 | 20.01621 |
March | 514.00000 | 21.05425 | 17.62504 | -0.5314 | 13.52820 |
April | 485.00000 | 21.98468 | 19.01024 | -0.2193 | 9.28940 |
May | 508.00000 | 23.46377 | 32.29368 | -0.6301 | 17.98334 |
June | 496.00000 | 23.72249 | 45.82619 | -0.4239 | 11.85474 |
July | 497.00000 | 24.16371 | 52.06724 | -0.2113 | 8.57225 |
August | 514.00000 | 23.66034 | 52.51591 | -0.4149 | 11.74028 |
September | 485.00000 | 22.75516 | 40.50589 | -0.8682 | 24.74465 |
October | 502.00000 | 21.51763 | 30.65331 | -0.2912 | 8.55493 |
November | 489.00000 | 20.52051 | 21.53778 | -0.6541 | 16.04323 |
December | 497.00000 | 19.96973 | 14.23392 | -0.9202 | 25.19966 |
Annual Sum or Average | 5943.00000 | 21.93949 | 29.52488 | -0.5731 | 16.16541 |
Minimum of Months | 454.00000 | 19.91785 | 12.20123 | -0.9616 | 8.55493 |
Maximum of Months | 514.00000 | 24.16371 | 52.51591 | -0.2113 | 26.99068 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 19.55637 | 12.76239 | -1.1574 | 35.08037 |
February | 454.00000 | 19.78339 | 14.99777 | -1.0397 | 30.17217 |
March | 514.00000 | 20.22036 | 19.36502 | -0.8544 | 22.70954 |
April | 485.00000 | 20.88219 | 21.23404 | -0.5840 | 15.19467 |
May | 508.00000 | 23.07647 | 33.22978 | -0.8880 | 25.98838 |
June | 496.00000 | 23.74745 | 46.14951 | -0.5258 | 12.95357 |
July | 497.00000 | 24.08851 | 52.75971 | -0.3525 | 9.08351 |
August | 514.00000 | 23.56010 | 53.37426 | -0.5683 | 13.45609 |
September | 485.00000 | 22.33177 | 42.21950 | -1.1235 | 33.91298 |
October | 502.00000 | 20.63137 | 33.25996 | -0.5862 | 14.83537 |
November | 489.00000 | 19.89783 | 23.34869 | -0.9008 | 25.34174 |
December | 497.00000 | 19.60092 | 14.87659 | -1.1206 | 33.47998 |
Annual Sum or Average | 5943.00000 | 21.46443 | 30.77213 | -0.8062 | 22.60398 |
Minimum of Months | 454.00000 | 19.55637 | 12.76239 | -1.1574 | 9.08351 |
Maximum of Months | 514.00000 | 24.08851 | 53.37426 | -0.3525 | 35.08037 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 19.71073 | 12.30309 | -1.1003 | 32.63170 |
February | 454.00000 | 19.87785 | 14.51696 | -0.9741 | 27.67598 |
March | 514.00000 | 20.50880 | 18.57184 | -0.7350 | 19.02472 |
April | 485.00000 | 21.56397 | 19.98664 | -0.3589 | 12.26262 |
May | 508.00000 | 23.27422 | 32.66125 | -0.7237 | 21.07105 |
June | 496.00000 | 23.76581 | 45.77924 | -0.4017 | 11.98078 |
July | 497.00000 | 24.05077 | 52.33658 | -0.2398 | 8.99114 |
August | 514.00000 | 23.44988 | 53.35900 | -0.5017 | 13.92600 |
September | 485.00000 | 22.43191 | 41.56045 | -1.0114 | 30.67575 |
October | 502.00000 | 20.86335 | 32.27386 | -0.5110 | 13.53871 |
November | 489.00000 | 19.93154 | 22.87002 | -0.8748 | 24.38334 |
December | 497.00000 | 19.71227 | 14.44444 | -1.0816 | 31.84472 |
Annual Sum or Average | 5943.00000 | 21.61087 | 30.19740 | -0.7072 | 20.59055 |
Minimum of Months | 454.00000 | 19.71073 | 12.30309 | -1.1003 | 8.99114 |
Maximum of Months | 514.00000 | 24.05077 | 53.35900 | -0.2398 | 32.63170 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 19.99267 | 12.28974 | -0.9477 | 28.33047 |
February | 454.00000 | 20.58303 | 14.06146 | -0.7227 | 21.88836 |
March | 514.00000 | 21.24604 | 17.97659 | -0.5225 | 16.14035 |
April | 485.00000 | 21.85306 | 19.70754 | -0.2856 | 12.35819 |
May | 508.00000 | 23.25206 | 32.68366 | -0.7540 | 22.11153 |
June | 496.00000 | 23.53965 | 46.43064 | -0.5335 | 14.73828 |
July | 497.00000 | 23.98686 | 52.72116 | -0.3106 | 10.00505 |
August | 514.00000 | 23.65144 | 52.73054 | -0.4394 | 12.81606 |
September | 485.00000 | 22.95640 | 40.34220 | -0.8152 | 25.74201 |
October | 502.00000 | 21.49929 | 31.18999 | -0.3267 | 13.16172 |
November | 489.00000 | 20.40221 | 22.45265 | -0.7151 | 20.83332 |
December | 497.00000 | 19.90020 | 14.47922 | -0.9711 | 28.29014 |
Annual Sum or Average | 5943.00000 | 21.91819 | 29.89890 | -0.6109 | 18.82747 |
Minimum of Months | 454.00000 | 19.90020 | 12.28974 | -0.9711 | 10.00505 |
Maximum of Months | 514.00000 | 23.98686 | 52.73054 | -0.2856 | 28.33047 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 19.75312 | 12.20221 | -1.0701 | 31.47306 |
February | 454.00000 | 20.04678 | 14.29505 | -0.9068 | 25.40615 |
March | 514.00000 | 20.67388 | 18.33771 | -0.6777 | 18.11020 |
April | 485.00000 | 21.45146 | 20.00872 | -0.3775 | 12.66985 |
May | 508.00000 | 23.12910 | 32.77166 | -0.7495 | 22.91817 |
June | 496.00000 | 23.49469 | 46.48687 | -0.4940 | 14.46994 |
July | 497.00000 | 24.01475 | 52.57157 | -0.2529 | 9.82613 |
August | 514.00000 | 23.43538 | 53.32436 | -0.4873 | 14.01015 |
September | 485.00000 | 22.35140 | 41.59892 | -1.0238 | 31.45328 |
October | 502.00000 | 21.00046 | 31.95481 | -0.4552 | 12.33837 |
November | 489.00000 | 20.05720 | 22.64525 | -0.8170 | 22.27864 |
December | 497.00000 | 19.77211 | 14.32912 | -1.0325 | 29.89656 |
Annual Sum or Average | 5943.00000 | 21.61351 | 30.18668 | -0.6933 | 20.34213 |
Minimum of Months | 454.00000 | 19.75312 | 12.20221 | -1.0701 | 9.82613 |
Maximum of Months | 514.00000 | 24.01475 | 53.32436 | -0.2529 | 31.47306 |
Report: ChillerReportMonthly
For: COOLSYS1 CHILLER1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportCHILLER ELECTRICITY ENERGY [J] | CHILLER ELECTRICITY RATE {Maximum} [W] | CHILLER ELECTRICITY RATE {TIMESTAMP} | CHILLER ELECTRICITY ENERGY {HOURS NON-ZERO} [HOURS] | CHILLER EVAPORATOR COOLING ENERGY [J] | CHILLER EVAPORATOR COOLING RATE [] | CHILLER CONDENSER HEAT TRANSFER ENERGY [J] | CHILLER COP [W/W] | CHILLER COP {Maximum} [W/W] | CHILLER COP {TIMESTAMP} | CHILLER PART LOAD RATIO [] | CHILLER PART LOAD RATIO [] | |
January | 0.152675E+10 | 3171.16 | 19-JAN-07:20 | 135.39 | 0.695438E+10 | 0.00 | 0.848113E+10 | 0.83 | 4.56 | 21-JAN-07:50 | 0.00 | 0.00 |
February | 0.163980E+10 | 3988.51 | 13-FEB-11:00 | 144.23 | 0.746916E+10 | 0.00 | 0.910896E+10 | 0.98 | 4.56 | 22-FEB-19:10 | 0.00 | 0.00 |
March | 0.194173E+10 | 6897.68 | 27-MAR-13:50 | 166.45 | 0.884392E+10 | 0.00 | 0.107857E+11 | 1.02 | 4.56 | 22-MAR-11:20 | 0.00 | 0.00 |
April | 0.900300E+10 | 84895.11 | 13-APR-15:20 | 113.77 | 0.490442E+11 | 0.00 | 0.580472E+11 | 0.77 | 7.23 | 13-APR-15:20 | 0.00 | 0.00 |
May | 0.514205E+11 | 110626.95 | 26-MAY-11:00 | 247.30 | 0.328575E+12 | 0.00 | 0.379996E+12 | 1.94 | 7.37 | 26-MAY-08:30 | 0.00 | 0.00 |
June | 0.102372E+12 | 171074.30 | 30-JUN-05:03 | 407.11 | 0.675390E+12 | 0.00 | 0.777761E+12 | 3.49 | 7.57 | 29-JUN-03:02 | 0.00 | 0.00 |
July | 0.125815E+12 | 193658.18 | 05-JUL-10:20 | 502.95 | 0.838523E+12 | 0.00 | 0.964338E+12 | 4.15 | 7.75 | 22-JUL-05:03 | 0.00 | 0.00 |
August | 0.104055E+12 | 166474.45 | 31-AUG-12:50 | 485.43 | 0.679939E+12 | 0.00 | 0.783993E+12 | 3.86 | 7.74 | 09-AUG-05:03 | 0.00 | 0.00 |
September | 0.315208E+11 | 114265.04 | 07-SEP-14:10 | 193.79 | 0.188481E+12 | 0.00 | 0.220002E+12 | 1.45 | 7.47 | 01-SEP-08:30 | 0.00 | 0.00 |
October | 0.674072E+10 | 93592.99 | 19-OCT-13:50 | 89.47 | 0.379750E+11 | 0.00 | 0.447158E+11 | 0.59 | 7.34 | 19-OCT-13:50 | 0.00 | 0.00 |
November | 0.201087E+10 | 52400.44 | 01-NOV-15:00 | 100.61 | 0.908955E+10 | 0.00 | 0.111004E+11 | 0.64 | 4.56 | 30-NOV-13:50 | 0.00 | 0.00 |
December | 0.183504E+10 | 5615.09 | 18-DEC-16:30 | 161.57 | 0.835899E+10 | 0.00 | 0.101940E+11 | 0.99 | 4.56 | 31-DEC-23:40 | 0.00 | 0.00 |
Annual Sum or Average | 0.439880E+12 | 2748.05 | 0.283864E+13 | 0.00 | 0.327852E+13 | 1.73 | 0.00 | 0.00 | ||||
Minimum of Months | 0.152675E+10 | 3171.16 | 89.47 | 0.695438E+10 | 0.00 | 0.848113E+10 | 0.59 | 4.56 | 0.00 | 0.00 | ||
Maximum of Months | 0.125815E+12 | 193658.18 | 502.95 | 0.838523E+12 | 0.00 | 0.964338E+12 | 4.15 | 7.75 | 0.00 | 0.00 |
Report: ChillerReportMonthly
For: COOLSYS1 CHILLER2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportCHILLER ELECTRICITY ENERGY [J] | CHILLER ELECTRICITY RATE {Maximum} [W] | CHILLER ELECTRICITY RATE {TIMESTAMP} | CHILLER ELECTRICITY ENERGY {HOURS NON-ZERO} [HOURS] | CHILLER EVAPORATOR COOLING ENERGY [J] | CHILLER EVAPORATOR COOLING RATE [] | CHILLER CONDENSER HEAT TRANSFER ENERGY [J] | CHILLER COP [W/W] | CHILLER COP {Maximum} [W/W] | CHILLER COP {TIMESTAMP} | CHILLER PART LOAD RATIO [] | CHILLER PART LOAD RATIO [] | |
January | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
May | 0.107624E+11 | 110626.95 | 26-MAY-11:00 | 30.17 | 0.769527E+11 | 0.00 | 0.877152E+11 | 0.29 | 7.33 | 17-MAY-13:10 | 0.00 | 0.00 |
June | 0.290565E+11 | 171074.30 | 30-JUN-05:03 | 70.98 | 0.202090E+12 | 0.00 | 0.231147E+12 | 0.69 | 7.57 | 29-JUN-03:02 | 0.00 | 0.00 |
July | 0.443902E+11 | 193658.18 | 05-JUL-10:20 | 109.37 | 0.315391E+12 | 0.00 | 0.359782E+12 | 1.04 | 7.75 | 22-JUL-05:03 | 0.00 | 0.00 |
August | 0.309314E+11 | 166474.45 | 31-AUG-12:50 | 79.82 | 0.219780E+12 | 0.00 | 0.250711E+12 | 0.76 | 7.74 | 09-AUG-05:03 | 0.00 | 0.00 |
September | 0.290804E+10 | 113419.64 | 01-SEP-12:20 | 8.00 | 0.210881E+11 | 0.00 | 0.239961E+11 | 0.08 | 7.34 | 01-SEP-12:10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.118049E+12 | 298.34 | 0.835302E+12 | 0.00 | 0.953351E+12 | 0.24 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.443902E+11 | 193658.18 | 109.37 | 0.315391E+12 | 0.00 | 0.359782E+12 | 1.04 | 7.75 | 0.00 | 0.00 |
Report: TowerReportMonthly
For: CENTRAL TOWER
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportCOOLING TOWER FAN ELECTRICITY ENERGY [J] | COOLING TOWER FAN ELECTRICITY ENERGY {HOURS NON-ZERO} [HOURS] | COOLING TOWER FAN ELECTRICITY RATE {Maximum} [W] | COOLING TOWER FAN ELECTRICITY RATE {TIMESTAMP} | COOLING TOWER HEAT TRANSFER RATE {Maximum} [W] | COOLING TOWER HEAT TRANSFER RATE {TIMESTAMP} | COOLING TOWER INLET TEMPERATURE [C] | COOLING TOWER OUTLET TEMPERATURE [C] | COOLING TOWER MASS FLOW RATE [kg/s] | |
January | 0.509823E+10 | 744.00 | 3533.12 | 29-JAN-15:00 | 296611.85 | 25-JAN-15:43 | 21.36 | 18.33 | 14.37 |
February | 0.977681E+10 | 672.00 | 13561.33 | 20-FEB-16:00 | 412781.96 | 22-FEB-16:00 | 24.27 | 18.33 | 14.32 |
March | 0.189346E+11 | 744.00 | 33770.38 | 26-MAR-16:00 | 594808.65 | 31-MAR-24:00 | 27.20 | 18.33 | 14.36 |
April | 0.595330E+11 | 720.00 | 49248.27 | 11-APR-10:40 | 673066.48 | 23-APR-18:31 | 30.63 | 18.81 | 14.41 |
May | 0.666088E+11 | 744.00 | 49248.27 | 02-MAY-13:10 | 319140.38 | 31-MAY-24:00 | 23.70 | 19.83 | 14.36 |
June | 0.109303E+12 | 720.00 | 49248.27 | 01-JUN-06:20 | 482055.53 | 30-JUN-23:23 | 29.23 | 22.43 | 14.44 |
July | 0.126971E+12 | 744.00 | 49248.27 | 01-JUL-00:10 | 618966.87 | 31-JUL-24:00 | 34.36 | 24.59 | 14.44 |
August | 0.129206E+12 | 744.00 | 49248.27 | 01-AUG-00:03 | 697181.69 | 08-AUG-16:10 | 36.45 | 24.00 | 14.44 |
September | 0.540970E+11 | 720.00 | 49248.27 | 01-SEP-00:03 | 319283.73 | 30-SEP-24:00 | 22.65 | 18.89 | 14.40 |
October | 0.325075E+11 | 744.00 | 49248.27 | 01-OCT-11:53 | 447999.49 | 31-OCT-24:00 | 24.89 | 18.46 | 14.27 |
November | 0.251726E+11 | 720.00 | 49248.27 | 01-NOV-09:40 | 520786.92 | 22-NOV-13:44 | 27.25 | 18.36 | 14.37 |
December | 0.168858E+11 | 744.00 | 14632.58 | 28-DEC-03:00 | 594128.28 | 14-DEC-13:03 | 29.61 | 18.33 | 14.43 |
Annual Sum or Average | 0.654094E+12 | 8760.00 | 27.66 | 19.91 | 14.38 | ||||
Minimum of Months | 0.509823E+10 | 672.00 | 3533.12 | 296611.85 | 21.36 | 18.33 | 14.27 | ||
Maximum of Months | 0.129206E+12 | 744.00 | 49248.27 | 697181.69 | 36.45 | 24.59 | 14.44 |
Report: TowerReportMonthly
For: TOWERWATERSYS COOLTOWER 1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportCOOLING TOWER FAN ELECTRICITY ENERGY [J] | COOLING TOWER FAN ELECTRICITY ENERGY {HOURS NON-ZERO} [HOURS] | COOLING TOWER FAN ELECTRICITY RATE {Maximum} [W] | COOLING TOWER FAN ELECTRICITY RATE {TIMESTAMP} | COOLING TOWER HEAT TRANSFER RATE {Maximum} [W] | COOLING TOWER HEAT TRANSFER RATE {TIMESTAMP} | COOLING TOWER INLET TEMPERATURE [C] | COOLING TOWER OUTLET TEMPERATURE [C] | COOLING TOWER MASS FLOW RATE [kg/s] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 239591.01 | 10-JAN-19:20 | 21.00 | 20.97 | 2.18 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 239595.11 | 14-FEB-20:40 | 21.03 | 20.99 | 2.42 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 239595.58 | 13-MAR-21:00 | 20.99 | 20.96 | 2.58 |
April | 66982767.09 | 24.88 | 3029.63 | 23-APR-16:20 | 715828.54 | 13-APR-15:20 | 20.99 | 20.90 | 5.52 |
May | 0.373313E+10 | 200.53 | 19236.99 | 16-MAY-12:10 | 1159276.53 | 17-MAY-11:00 | 21.85 | 21.27 | 20.11 |
June | 0.118947E+11 | 372.29 | 19236.99 | 06-JUN-09:50 | 1319852.12 | 19-JUN-15:10 | 23.08 | 21.88 | 35.91 |
July | 0.185928E+11 | 460.21 | 19236.99 | 03-JUL-05:04 | 1533759.14 | 05-JUL-15:25 | 23.47 | 22.05 | 42.81 |
August | 0.124902E+11 | 406.54 | 19236.99 | 03-AUG-13:50 | 1288690.77 | 31-AUG-12:50 | 22.70 | 21.55 | 40.37 |
September | 0.128812E+10 | 144.17 | 19236.99 | 01-SEP-08:20 | 1191965.21 | 07-SEP-13:30 | 21.46 | 21.12 | 15.97 |
October | 53678476.21 | 28.38 | 2456.40 | 19-OCT-13:50 | 933971.54 | 19-OCT-14:30 | 21.13 | 21.06 | 4.03 |
November | 7240997.11 | 5.83 | 536.89 | 01-NOV-15:00 | 306653.19 | 01-NOV-15:00 | 21.02 | 21.00 | 1.99 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 239595.51 | 13-DEC-20:30 | 21.02 | 20.99 | 2.42 |
Annual Sum or Average | 0.481269E+11 | 1642.83 | 21.65 | 21.23 | 14.79 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 239591.01 | 20.99 | 20.90 | 1.99 | ||
Maximum of Months | 0.185928E+11 | 460.21 | 19236.99 | 1533759.14 | 23.47 | 22.05 | 42.81 |
Report: TowerReportMonthly
For: TOWERWATERSYS COOLTOWER 2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportCOOLING TOWER FAN ELECTRICITY ENERGY [J] | COOLING TOWER FAN ELECTRICITY ENERGY {HOURS NON-ZERO} [HOURS] | COOLING TOWER FAN ELECTRICITY RATE {Maximum} [W] | COOLING TOWER FAN ELECTRICITY RATE {TIMESTAMP} | COOLING TOWER HEAT TRANSFER RATE {Maximum} [W] | COOLING TOWER HEAT TRANSFER RATE {TIMESTAMP} | COOLING TOWER INLET TEMPERATURE [C] | COOLING TOWER OUTLET TEMPERATURE [C] | COOLING TOWER MASS FLOW RATE [kg/s] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 21.00 | 21.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 21.03 | 21.03 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 20.99 | 20.99 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 20.99 | 20.99 | 0.00 |
May | 0.131581E+10 | 19.00 | 19236.99 | 16-MAY-12:10 | 1159276.53 | 17-MAY-11:00 | 21.85 | 21.77 | 1.67 |
June | 0.483655E+10 | 70.28 | 19236.99 | 06-JUN-12:50 | 1319852.12 | 19-JUN-15:10 | 23.08 | 22.75 | 6.25 |
July | 0.790584E+10 | 114.29 | 19236.99 | 03-JUL-12:10 | 1533759.14 | 05-JUL-15:25 | 23.47 | 22.95 | 9.75 |
August | 0.534981E+10 | 77.25 | 19236.99 | 04-AUG-13:30 | 1288690.77 | 31-AUG-12:50 | 22.70 | 22.36 | 6.74 |
September | 0.522946E+09 | 7.83 | 19236.99 | 01-SEP-09:00 | 1178507.54 | 07-SEP-13:40 | 21.46 | 21.42 | 0.71 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 21.13 | 21.13 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 21.02 | 21.02 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 21.02 | 21.02 | 0.00 |
Annual Sum or Average | 0.199310E+11 | 288.66 | 21.65 | 21.54 | 2.11 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 20.99 | 20.99 | 0.00 | ||
Maximum of Months | 0.790584E+10 | 114.29 | 19236.99 | 1533759.14 | 23.47 | 22.95 | 9.75 |
Report: BoilerReportMonthly
For: HEATSYS1 BOILER
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportBOILER HEATING ENERGY [J] | BOILER GAS CONSUMPTION [] | BOILER HEATING ENERGY {HOURS NON-ZERO} [HOURS] | BOILER HEATING RATE {Maximum} [W] | BOILER HEATING RATE {TIMESTAMP} | BOILER GAS CONSUMPTION RATE [] | BOILER INLET TEMPERATURE [C] | BOILER OUTLET TEMPERATURE [C] | BOILER MASS FLOW RATE [kg/s] | BOILER ANCILLARY ELECTRICITY RATE [W] | BOILER PART LOAD RATIO [] | BOILER PART LOAD RATIO {Maximum} [] | BOILER PART LOAD RATIO {TIMESTAMP} | |
January | 0.106836E+13 | 0.00 | 656.72 | 2932018.98 | 09-JAN-07:02 | 0.00 | 34.98 | 76.45 | 2.55 | 0.00 | 0.11 | 0.79 | 09-JAN-07:02 |
February | 0.492352E+12 | 0.00 | 558.48 | 2613590.94 | 14-FEB-07:03 | 0.00 | 30.39 | 72.84 | 1.15 | 0.00 | 0.05 | 0.70 | 14-FEB-07:03 |
March | 0.232524E+12 | 0.00 | 523.29 | 1890457.93 | 15-MAR-06:53 | 0.00 | 27.43 | 64.90 | 0.42 | 0.00 | 0.02 | 0.51 | 15-MAR-06:53 |
April | 0.646195E+11 | 0.00 | 311.37 | 1599543.07 | 10-APR-04:01 | 0.00 | 26.42 | 49.22 | 0.12 | 0.00 | 0.01 | 0.43 | 10-APR-04:01 |
May | 0.471051E+10 | 0.00 | 81.08 | 417584.55 | 02-MAY-06:10 | 0.00 | 26.95 | 32.70 | 0.01 | 0.00 | 0.00 | 0.11 | 02-MAY-06:10 |
June | 0.229922E+09 | 0.00 | 18.40 | 103021.68 | 03-JUN-06:10 | 0.00 | 24.82 | 26.20 | 0.00 | 0.00 | 0.00 | 0.03 | 03-JUN-06:10 |
July | 1729552.63 | 0.00 | 3.33 | 456.63 | 18-JUL-06:10 | 0.00 | 24.24 | 24.48 | 0.00 | 0.00 | 0.00 | 0.00 | 18-JUL-06:10 |
August | 0.235081E+09 | 0.00 | 15.08 | 105376.01 | 19-AUG-06:13 | 0.00 | 24.03 | 25.17 | 0.00 | 0.00 | 0.00 | 0.03 | 19-AUG-06:13 |
September | 0.658749E+10 | 0.00 | 136.39 | 354752.20 | 06-SEP-06:10 | 0.00 | 25.53 | 35.74 | 0.01 | 0.00 | 0.00 | 0.10 | 06-SEP-06:10 |
October | 0.671544E+11 | 0.00 | 351.56 | 1604183.06 | 30-OCT-04:01 | 0.00 | 24.96 | 50.32 | 0.12 | 0.00 | 0.01 | 0.43 | 30-OCT-04:01 |
November | 0.226900E+12 | 0.00 | 515.74 | 2135164.95 | 27-NOV-05:11 | 0.00 | 27.80 | 65.46 | 0.43 | 0.00 | 0.02 | 0.57 | 27-NOV-05:11 |
December | 0.791216E+12 | 0.00 | 646.09 | 2575060.47 | 26-DEC-07:03 | 0.00 | 32.61 | 75.18 | 1.71 | 0.00 | 0.08 | 0.69 | 26-DEC-07:03 |
Annual Sum or Average | 0.295489E+13 | 0.00 | 3817.54 | 0.00 | 27.50 | 49.76 | 0.54 | 0.00 | 0.03 | ||||
Minimum of Months | 1729552.63 | 0.00 | 3.33 | 456.63 | 0.00 | 24.03 | 24.48 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.106836E+13 | 0.00 | 656.72 | 2932018.98 | 0.00 | 34.98 | 76.45 | 2.55 | 0.00 | 0.11 | 0.79 |
Report: BoilerReportMonthly
For: CENTRAL BOILER
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportBOILER HEATING ENERGY [J] | BOILER GAS CONSUMPTION [] | BOILER HEATING ENERGY {HOURS NON-ZERO} [HOURS] | BOILER HEATING RATE {Maximum} [W] | BOILER HEATING RATE {TIMESTAMP} | BOILER GAS CONSUMPTION RATE [] | BOILER INLET TEMPERATURE [C] | BOILER OUTLET TEMPERATURE [C] | BOILER MASS FLOW RATE [kg/s] | BOILER ANCILLARY ELECTRICITY RATE [W] | BOILER PART LOAD RATIO [] | BOILER PART LOAD RATIO [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 21.36 | 21.36 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 24.27 | 24.27 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 27.20 | 27.20 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 30.63 | 30.63 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 23.70 | 23.70 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 29.23 | 29.23 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 34.36 | 34.36 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 36.45 | 36.45 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 22.65 | 22.65 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 24.89 | 24.89 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 27.25 | 27.25 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 29.61 | 29.61 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 27.66 | 27.66 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.36 | 21.36 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.45 | 36.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: VAV_BOT WITH REHEAT COOLING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 7632888.20 | 0.00 | 19.50 | 7632888.20 | 0.00 | 0.00 | 0.00 | 0.00 | 3987.55 | 27-JAN-15:27 | 3987.55 | 27-JAN-15:27 | 0.00 | 0.00 | 0.00 |
February | 34631270.58 | 0.00 | 23.14 | 34631270.58 | 0.00 | 0.00 | 0.00 | 0.00 | 5531.22 | 10-FEB-15:30 | 5531.22 | 10-FEB-15:30 | 0.00 | 0.00 | 0.00 |
March | 0.126098E+09 | 0.00 | 55.13 | 0.126098E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 32937.94 | 15-MAR-10:15 | 32937.94 | 15-MAR-10:15 | 0.00 | 0.00 | 0.00 |
April | 0.469924E+10 | 0.00 | 67.41 | 0.469924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 88947.90 | 23-APR-15:22 | 88947.90 | 23-APR-15:22 | 0.00 | 0.00 | 0.00 |
May | 0.368903E+11 | 0.00 | 229.43 | 0.360394E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 132925.20 | 26-MAY-11:00 | 113522.56 | 18-MAY-15:00 | 0.00 | 0.00 | 0.00 |
June | 0.880316E+11 | 0.00 | 392.13 | 0.698520E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 216460.70 | 19-JUN-15:30 | 130132.62 | 30-JUN-05:03 | 0.00 | 0.00 | 0.00 |
July | 0.121069E+12 | 0.00 | 486.11 | 0.901913E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 277290.80 | 05-JUL-10:30 | 132380.67 | 24-JUL-14:30 | 0.00 | 0.00 | 0.00 |
August | 0.946235E+11 | 0.00 | 467.94 | 0.706502E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 229570.45 | 31-AUG-12:50 | 132238.17 | 08-AUG-15:10 | 0.00 | 0.00 | 0.00 |
September | 0.189854E+11 | 0.00 | 173.94 | 0.168612E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 142763.41 | 01-SEP-13:10 | 118927.88 | 01-SEP-15:50 | 0.00 | 0.00 | 0.00 |
October | 0.321494E+10 | 0.00 | 53.58 | 0.321494E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 75771.02 | 19-OCT-15:00 | 75771.02 | 19-OCT-15:00 | 0.00 | 0.00 | 0.00 |
November | 0.443683E+09 | 0.00 | 39.16 | 0.443683E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 24618.16 | 01-NOV-15:00 | 24618.16 | 01-NOV-15:00 | 0.00 | 0.00 | 0.00 |
December | 29889424.99 | 0.00 | 35.22 | 29889424.99 | 0.00 | 0.00 | 0.00 | 0.00 | 5625.96 | 27-DEC-08:20 | 5625.96 | 27-DEC-08:20 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.368156E+12 | 0.00 | 2042.70 | 0.292150E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 7632888.20 | 0.00 | 19.50 | 7632888.20 | 0.00 | 0.00 | 0.00 | 0.00 | 3987.55 | 3987.55 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.121069E+12 | 0.00 | 486.11 | 0.901913E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 277290.80 | 132380.67 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: VAV_MID WITH REHEAT COOLING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 1544876.73 | 0.00 | 32.05 | 1544876.73 | 0.00 | 0.00 | 0.00 | 0.00 | 459.60 | 27-JAN-13:10 | 459.60 | 27-JAN-13:10 | 0.00 | 0.00 | 0.00 |
February | 0.116206E+09 | 0.00 | 34.30 | 0.116206E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11481.26 | 08-FEB-14:00 | 11481.26 | 08-FEB-14:00 | 0.00 | 0.00 | 0.00 |
March | 0.152171E+09 | 0.00 | 53.86 | 0.152171E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 28256.66 | 23-MAR-09:47 | 28256.66 | 23-MAR-09:47 | 0.00 | 0.00 | 0.00 |
April | 0.345965E+11 | 0.00 | 69.59 | 0.345965E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 825591.51 | 23-APR-16:01 | 825591.51 | 23-APR-16:01 | 0.00 | 0.00 | 0.00 |
May | 0.333085E+12 | 0.00 | 229.78 | 0.324811E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 1265105.07 | 26-MAY-11:00 | 1105203.05 | 18-MAY-15:00 | 0.00 | 0.00 | 0.00 |
June | 0.756544E+12 | 0.00 | 365.59 | 0.603393E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 2248250.81 | 30-JUN-05:03 | 1433316.31 | 30-JUN-05:03 | 0.00 | 0.00 | 0.00 |
July | 0.969724E+12 | 0.00 | 414.26 | 0.742572E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 2435409.55 | 05-JUL-10:35 | 1170012.07 | 24-JUL-15:20 | 0.00 | 0.00 | 0.00 |
August | 0.731377E+12 | 0.00 | 400.28 | 0.556437E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 1817441.51 | 31-AUG-12:50 | 1148371.09 | 08-AUG-15:20 | 0.00 | 0.00 | 0.00 |
September | 0.165043E+12 | 0.00 | 172.21 | 0.148679E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 1305593.53 | 01-SEP-12:20 | 1090619.43 | 01-SEP-16:00 | 0.00 | 0.00 | 0.00 |
October | 0.286663E+11 | 0.00 | 58.54 | 0.286663E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 617765.41 | 19-OCT-15:00 | 617765.41 | 19-OCT-15:00 | 0.00 | 0.00 | 0.00 |
November | 0.299395E+10 | 0.00 | 37.27 | 0.299395E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 170758.86 | 01-NOV-15:00 | 170758.86 | 01-NOV-15:00 | 0.00 | 0.00 | 0.00 |
December | 2385345.96 | 0.00 | 27.10 | 2385345.96 | 0.00 | 0.00 | 0.00 | 0.00 | 302.53 | 30-DEC-08:50 | 302.53 | 30-DEC-08:50 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.302230E+13 | 0.00 | 1894.83 | 0.244242E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 1544876.73 | 0.00 | 27.10 | 1544876.73 | 0.00 | 0.00 | 0.00 | 0.00 | 302.53 | 302.53 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.969724E+12 | 0.00 | 414.26 | 0.742572E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 2435409.55 | 1433316.31 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: VAV_TOP WITH REHEAT COOLING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 492153.63 | 0.00 | 0.30 | 492153.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1893.40 | 24-JAN-05:51 | 1893.40 | 24-JAN-05:51 | 0.00 | 0.00 | 0.00 |
February | 6264841.43 | 0.00 | 8.90 | 6264841.43 | 0.00 | 0.00 | 0.00 | 0.00 | 1251.90 | 08-FEB-13:10 | 1251.90 | 08-FEB-13:10 | 0.00 | 0.00 | 0.00 |
March | 27947230.70 | 0.00 | 39.03 | 27947230.70 | 0.00 | 0.00 | 0.00 | 0.00 | 1704.86 | 28-MAR-15:50 | 1704.86 | 28-MAR-15:50 | 0.00 | 0.00 | 0.00 |
April | 0.320805E+10 | 0.00 | 90.70 | 0.320805E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 92079.39 | 23-APR-15:51 | 92079.39 | 23-APR-15:51 | 0.00 | 0.00 | 0.00 |
May | 0.354253E+11 | 0.00 | 223.21 | 0.345371E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 141092.51 | 25-MAY-16:00 | 132885.44 | 18-MAY-14:40 | 0.00 | 0.00 | 0.00 |
June | 0.799198E+11 | 0.00 | 362.00 | 0.641583E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 239595.05 | 30-JUN-05:03 | 149508.22 | 30-JUN-05:03 | 0.00 | 0.00 | 0.00 |
July | 0.103774E+12 | 0.00 | 409.08 | 0.794686E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 247584.77 | 05-JUL-10:35 | 140391.34 | 24-JUL-14:40 | 0.00 | 0.00 | 0.00 |
August | 0.757541E+11 | 0.00 | 392.09 | 0.576696E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 204143.50 | 29-AUG-15:40 | 135319.53 | 08-AUG-15:20 | 0.00 | 0.00 | 0.00 |
September | 0.155332E+11 | 0.00 | 163.51 | 0.140083E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 150609.78 | 01-SEP-14:00 | 125566.58 | 01-SEP-16:00 | 0.00 | 0.00 | 0.00 |
October | 0.251675E+10 | 0.00 | 77.67 | 0.251675E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60717.96 | 19-OCT-15:00 | 60717.96 | 19-OCT-15:00 | 0.00 | 0.00 | 0.00 |
November | 0.261298E+09 | 0.00 | 50.36 | 0.261298E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14194.10 | 01-NOV-15:00 | 14194.10 | 01-NOV-15:00 | 0.00 | 0.00 | 0.00 |
December | 308613.59 | 0.00 | 0.16 | 308613.59 | 0.00 | 0.00 | 0.00 | 0.00 | 1060.07 | 15-DEC-04:42 | 1060.07 | 15-DEC-04:42 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.316427E+12 | 0.00 | 1816.98 | 0.255863E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 308613.59 | 0.00 | 0.16 | 308613.59 | 0.00 | 0.00 | 0.00 | 0.00 | 1060.07 | 1060.07 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.103774E+12 | 0.00 | 409.08 | 0.794686E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 247584.77 | 149508.22 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: CAV_BAS COOLING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 28581521.05 | 0.00 | 109.86 | 28581521.05 | 0.00 | 0.00 | 0.00 | 0.00 | 6440.71 | 31-JAN-19:00 | 6440.71 | 31-JAN-19:00 | 0.00 | 0.00 | 0.00 |
February | 42141558.90 | 0.00 | 114.78 | 42141558.90 | 0.00 | 0.00 | 0.00 | 0.00 | 19797.47 | 13-FEB-11:00 | 19797.47 | 13-FEB-11:00 | 0.00 | 0.00 | 0.00 |
March | 27748330.04 | 0.00 | 119.11 | 27748330.04 | 0.00 | 0.00 | 0.00 | 0.00 | 5864.57 | 15-MAR-06:40 | 5864.57 | 15-MAR-06:40 | 0.00 | 0.00 | 0.00 |
April | 0.723343E+09 | 0.00 | 25.22 | 0.723343E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25909.14 | 13-APR-16:00 | 25909.14 | 13-APR-16:00 | 0.00 | 0.00 | 0.00 |
May | 0.183804E+11 | 0.00 | 162.52 | 0.182400E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 80258.35 | 26-MAY-04:02 | 55151.86 | 18-MAY-14:00 | 0.00 | 0.00 | 0.00 |
June | 0.415781E+11 | 0.00 | 286.98 | 0.353558E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 185856.39 | 30-JUN-03:02 | 85338.94 | 30-JUN-05:05 | 0.00 | 0.00 | 0.00 |
July | 0.553168E+11 | 0.00 | 328.85 | 0.454479E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 165160.68 | 05-JUL-10:10 | 69499.94 | 24-JUL-09:10 | 0.00 | 0.00 | 0.00 |
August | 0.449551E+11 | 0.00 | 310.17 | 0.361195E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 116299.03 | 09-AUG-03:02 | 64789.22 | 06-AUG-16:30 | 0.00 | 0.00 | 0.00 |
September | 0.833262E+10 | 0.00 | 104.12 | 0.777328E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 83563.97 | 01-SEP-03:52 | 58988.44 | 03-SEP-17:01 | 0.00 | 0.00 | 0.00 |
October | 0.112250E+10 | 0.00 | 18.62 | 0.112250E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43987.43 | 19-OCT-15:00 | 43987.43 | 19-OCT-15:00 | 0.00 | 0.00 | 0.00 |
November | 0.158960E+09 | 0.00 | 41.02 | 0.157626E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 13322.08 | 21-NOV-06:03 | 13193.73 | 01-NOV-15:00 | 0.00 | 0.00 | 0.00 |
December | 56930004.98 | 0.00 | 145.94 | 56930004.98 | 0.00 | 0.00 | 0.00 | 0.00 | 26701.47 | 18-DEC-16:30 | 26701.47 | 18-DEC-16:30 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.170723E+12 | 0.00 | 1767.20 | 0.145095E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 27748330.04 | 0.00 | 18.62 | 27748330.04 | 0.00 | 0.00 | 0.00 | 0.00 | 5864.57 | 5864.57 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.553168E+11 | 0.00 | 328.85 | 0.454479E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 185856.39 | 85338.94 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: AIRLOOP DATACENTER BASEMENT COOLING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.308505E+12 | 0.783549E+11 | 744.00 | 0.308499E+12 | 6001089.28 | 0.00 | 0.33 | 20-JAN-22:03 | 0.27 | 09-JAN-07:02 | 124662.62 | 20-JAN-22:10 | 124662.62 | 20-JAN-22:10 | 306.03 | 02-JAN-07:05 | 35317.43 | 27-JAN-14:20 | 0.00 |
February | 0.503923E+12 | 0.121323E+12 | 672.00 | 0.503923E+12 | -0.0 | 0.00 | 0.56 | 21-FEB-14:50 | 0.50 | 14-FEB-07:03 | 216420.11 | 22-FEB-22:10 | 216420.11 | 22-FEB-22:10 | 0.00 | 07-FEB-20:40 | 57736.39 | 21-FEB-14:50 | 0.00 |
March | 0.806810E+12 | 0.186028E+12 | 744.00 | 0.806810E+12 | 0.00 | 0.00 | 0.93 | 31-MAR-24:00 | 0.71 | 06-MAR-07:05 | 395074.20 | 31-MAR-24:00 | 395074.20 | 31-MAR-24:00 | 0.00 | 01-MAR-22:10 | 87597.59 | 31-MAR-24:00 | 0.00 |
April | 0.102578E+13 | 0.231402E+12 | 720.00 | 0.102578E+13 | 0.00 | 0.00 | 1.00 | 13-APR-15:00 | 0.36 | 30-APR-24:00 | 403884.58 | 23-APR-20:03 | 403884.58 | 23-APR-20:03 | 0.00 | 23-APR-20:03 | 130841.66 | 23-APR-16:00 | 0.00 |
May | 0.334445E+12 | 0.881570E+11 | 744.00 | 0.333146E+12 | 0.129826E+10 | 0.00 | 0.54 | 31-MAY-24:00 | 0.31 | 20-MAY-06:30 | 212009.76 | 31-MAY-24:00 | 212009.76 | 31-MAY-24:00 | 6541.24 | 26-MAY-13:20 | 50523.81 | 31-MAY-24:00 | 0.00 |
June | 0.566959E+12 | 0.152898E+12 | 720.00 | 0.561818E+12 | 0.514116E+10 | 0.00 | 0.75 | 30-JUN-23:12 | 0.53 | 16-JUN-06:10 | 305731.19 | 30-JUN-24:00 | 304778.22 | 30-JUN-23:55 | 11326.17 | 30-JUN-13:40 | 95841.69 | 29-JUN-16:00 | 0.00 |
July | 0.835293E+12 | 0.229587E+12 | 744.00 | 0.828757E+12 | 0.653625E+10 | 0.00 | 0.94 | 31-JUL-24:00 | 0.73 | 01-JUL-06:20 | 396893.33 | 31-JUL-24:00 | 396893.33 | 31-JUL-24:00 | 11337.50 | 25-JUL-15:00 | 118420.94 | 15-JUL-14:30 | 0.00 |
August | 0.107892E+13 | 0.280533E+12 | 744.00 | 0.107292E+13 | 0.599688E+10 | 0.00 | 1.00 | 04-AUG-13:20 | 0.38 | 31-AUG-24:00 | 417656.46 | 25-AUG-19:00 | 408984.70 | 09-AUG-21:02 | 11558.15 | 25-AUG-19:10 | 142193.68 | 08-AUG-16:00 | 0.00 |
September | 0.325809E+12 | 0.826760E+11 | 720.00 | 0.324275E+12 | 0.153412E+10 | 0.00 | 0.54 | 30-SEP-24:00 | 0.31 | 23-SEP-06:10 | 212604.82 | 30-SEP-24:00 | 212604.82 | 30-SEP-24:00 | 6977.24 | 18-SEP-16:00 | 50393.44 | 30-SEP-24:00 | 0.00 |
October | 0.574629E+12 | 0.138008E+12 | 744.00 | 0.574514E+12 | 0.114831E+09 | 0.00 | 0.74 | 31-OCT-24:00 | 0.52 | 30-OCT-06:10 | 303991.45 | 31-OCT-24:00 | 303991.45 | 31-OCT-24:00 | 2122.86 | 02-OCT-10:30 | 69696.36 | 31-OCT-24:00 | 0.00 |
November | 0.788135E+12 | 0.181431E+12 | 720.00 | 0.787998E+12 | 0.137157E+09 | 0.00 | 0.76 | 01-NOV-15:10 | 0.72 | 25-NOV-07:05 | 312382.01 | 21-NOV-14:10 | 310043.29 | 17-NOV-22:03 | 5230.36 | 21-NOV-14:10 | 80403.69 | 01-NOV-15:00 | 0.00 |
December | 0.104947E+13 | 0.233274E+12 | 744.00 | 0.104947E+13 | -0.0 | 0.00 | 0.94 | 08-DEC-22:02 | 0.89 | 26-DEC-07:03 | 401388.80 | 08-DEC-22:02 | 401388.80 | 08-DEC-22:02 | 0.00 | 03-DEC-08:20 | 88764.30 | 08-DEC-22:02 | 0.00 |
Annual Sum or Average | 0.819868E+13 | 0.200367E+13 | 8760.00 | 0.817792E+13 | 0.207647E+11 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.308505E+12 | 0.783549E+11 | 672.00 | 0.308499E+12 | -0.0 | 0.00 | 0.33 | 0.27 | 124662.62 | 124662.62 | 0.00 | 35317.43 | 0.00 | ||||||
Maximum of Months | 0.107892E+13 | 0.280533E+12 | 744.00 | 0.107292E+13 | 0.653625E+10 | 0.00 | 1.00 | 0.89 | 417656.46 | 408984.70 | 11558.15 | 142193.68 | 0.00 |
Report: DXReportMonthly
For: AIRLOOP DATACENTER BOT COOLING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.195333E+10 | 0.587470E+09 | 687.64 | 0.195331E+10 | 13114.07 | 0.00 | 0.25 | 20-JAN-16:30 | 0.00 | 01-JAN-00:01 | 1958.26 | 20-JAN-16:30 | 1958.26 | 20-JAN-16:30 | 2.33 | 01-JAN-16:10 | 527.23 | 20-JAN-16:30 | 0.00 |
February | 0.753800E+10 | 0.200731E+10 | 672.00 | 0.753800E+10 | 0.00 | 0.00 | 0.55 | 20-FEB-16:42 | 0.27 | 14-FEB-07:03 | 4416.73 | 20-FEB-16:45 | 4416.73 | 20-FEB-16:45 | 0.00 | 21-FEB-12:00 | 1144.60 | 20-FEB-16:42 | 0.00 |
March | 0.143917E+11 | 0.355926E+10 | 744.00 | 0.143917E+11 | -0.0 | 0.00 | 0.85 | 31-MAR-24:00 | 0.52 | 06-MAR-07:05 | 7653.38 | 31-MAR-24:00 | 7653.38 | 31-MAR-24:00 | 0.00 | 01-MAR-22:00 | 1774.38 | 31-MAR-24:00 | 0.00 |
April | 0.197991E+11 | 0.468692E+10 | 720.00 | 0.197991E+11 | 0.00 | 0.00 | 1.00 | 22-APR-17:15 | 0.31 | 30-APR-24:00 | 8801.65 | 16-APR-18:03 | 8801.65 | 16-APR-18:03 | 0.00 | 30-APR-24:00 | 2887.72 | 23-APR-16:00 | 0.00 |
May | 0.589576E+10 | 0.156803E+10 | 744.00 | 0.584964E+10 | 46116031.63 | 0.00 | 0.44 | 31-MAY-24:00 | 0.18 | 13-MAY-06:40 | 3878.16 | 31-MAY-24:00 | 3878.16 | 31-MAY-24:00 | 250.67 | 26-MAY-13:10 | 1105.25 | 25-MAY-18:30 | 0.00 |
June | 0.109648E+11 | 0.292603E+10 | 720.00 | 0.107624E+11 | 0.202404E+09 | 0.00 | 0.65 | 30-JUN-23:12 | 0.41 | 10-JUN-06:10 | 5996.22 | 30-JUN-23:03 | 5958.92 | 30-JUN-23:23 | 482.67 | 30-JUN-16:00 | 2039.36 | 29-JUN-16:00 | 0.00 |
July | 0.165799E+11 | 0.449075E+10 | 744.00 | 0.163071E+11 | 0.272799E+09 | 0.00 | 0.83 | 31-JUL-24:00 | 0.60 | 08-JUL-07:00 | 7840.36 | 31-JUL-23:42 | 7840.36 | 31-JUL-23:42 | 508.22 | 05-JUL-11:00 | 2418.80 | 21-JUL-16:00 | 0.00 |
August | 0.214782E+11 | 0.552903E+10 | 744.00 | 0.212062E+11 | 0.271922E+09 | 0.00 | 1.00 | 08-AUG-16:00 | 0.30 | 31-AUG-24:00 | 8956.87 | 25-AUG-18:20 | 8946.15 | 13-AUG-18:40 | 413.28 | 31-AUG-16:00 | 3153.09 | 08-AUG-16:00 | 0.00 |
September | 0.548185E+10 | 0.138677E+10 | 720.00 | 0.542338E+10 | 58470271.45 | 0.00 | 0.44 | 30-SEP-24:00 | 0.17 | 23-SEP-06:55 | 3912.08 | 30-SEP-24:00 | 3912.08 | 30-SEP-24:00 | 260.70 | 18-SEP-16:00 | 939.87 | 01-SEP-17:00 | 0.00 |
October | 0.101025E+11 | 0.244676E+10 | 744.00 | 0.100967E+11 | 5788462.67 | 0.00 | 0.63 | 31-OCT-24:00 | 0.34 | 30-OCT-06:30 | 5455.69 | 31-OCT-24:00 | 5455.69 | 31-OCT-24:00 | 93.56 | 02-OCT-10:50 | 1331.13 | 19-OCT-16:00 | 0.00 |
November | 0.140289E+11 | 0.342289E+10 | 720.00 | 0.140237E+11 | 5182075.78 | 0.00 | 0.74 | 12-NOV-15:52 | 0.53 | 25-NOV-07:05 | 6381.18 | 12-NOV-15:54 | 6381.18 | 12-NOV-15:54 | 195.10 | 21-NOV-12:10 | 1538.97 | 01-NOV-15:00 | 0.00 |
December | 0.184210E+11 | 0.450098E+10 | 744.00 | 0.184210E+11 | -0.0 | 0.00 | 0.92 | 10-DEC-15:53 | 0.70 | 26-DEC-07:03 | 7772.57 | 10-DEC-15:53 | 7772.57 | 10-DEC-15:53 | 0.00 | 03-DEC-01:12 | 1900.95 | 10-DEC-15:53 | 0.00 |
Annual Sum or Average | 0.146635E+12 | 0.371122E+11 | 8703.64 | 0.145772E+12 | 0.862695E+09 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.195333E+10 | 0.587470E+09 | 672.00 | 0.195331E+10 | -0.0 | 0.00 | 0.25 | 0.00 | 1958.26 | 1958.26 | 0.00 | 527.23 | 0.00 | ||||||
Maximum of Months | 0.214782E+11 | 0.552903E+10 | 744.00 | 0.212062E+11 | 0.272799E+09 | 0.00 | 1.00 | 0.70 | 8956.87 | 8946.15 | 508.22 | 3153.09 | 0.00 |
Report: DXReportMonthly
For: AIRLOOP DATACENTER MID COOLING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.216893E+10 | 0.722976E+09 | 181.42 | 0.216893E+10 | 0.00 | 0.00 | 0.20 | 20-JAN-16:30 | 0.00 | 01-JAN-00:01 | 14788.09 | 20-JAN-16:30 | 14788.09 | 20-JAN-16:30 | 0.00 | 19-JAN-13:05 | 4063.41 | 20-JAN-16:30 | 0.00 |
February | 0.478589E+11 | 0.131645E+11 | 672.00 | 0.478589E+11 | -0.0 | 0.00 | 0.49 | 08-FEB-17:00 | 0.10 | 13-FEB-07:03 | 39265.14 | 08-FEB-17:00 | 39265.14 | 08-FEB-17:00 | 0.00 | 03-FEB-02:40 | 9847.41 | 08-FEB-17:00 | 0.00 |
March | 0.117370E+12 | 0.295324E+11 | 744.00 | 0.117370E+12 | 0.00 | 0.00 | 0.81 | 31-MAR-23:30 | 0.36 | 06-MAR-07:05 | 68899.94 | 31-MAR-23:30 | 68899.94 | 31-MAR-23:30 | 0.00 | 02-MAR-03:55 | 16116.62 | 31-MAR-23:30 | 0.00 |
April | 0.176203E+12 | 0.421728E+11 | 720.00 | 0.176203E+12 | 0.00 | 0.00 | 1.00 | 22-APR-17:42 | 0.21 | 30-APR-24:00 | 83362.73 | 21-APR-18:10 | 83362.73 | 21-APR-18:10 | 0.00 | 03-APR-09:30 | 27689.45 | 23-APR-16:00 | 0.00 |
May | 0.516839E+11 | 0.138704E+11 | 744.00 | 0.512300E+11 | 0.453916E+09 | 0.00 | 0.41 | 31-MAY-24:00 | 0.10 | 01-MAY-06:05 | 34672.67 | 31-MAY-24:00 | 34672.67 | 31-MAY-24:00 | 2483.52 | 26-MAY-13:10 | 10747.74 | 25-MAY-18:20 | 0.00 |
June | 0.101645E+12 | 0.272647E+11 | 720.00 | 0.996409E+11 | 0.200447E+10 | 0.00 | 0.66 | 30-JUN-23:12 | 0.37 | 10-JUN-07:00 | 58589.68 | 30-JUN-24:00 | 58347.41 | 30-JUN-23:55 | 4811.42 | 30-JUN-16:00 | 19527.89 | 29-JUN-16:00 | 0.00 |
July | 0.157439E+12 | 0.427105E+11 | 744.00 | 0.154724E+12 | 0.271526E+10 | 0.00 | 0.83 | 31-JUL-24:00 | 0.57 | 08-JUL-17:00 | 74897.24 | 31-JUL-23:55 | 74897.24 | 31-JUL-23:55 | 5067.02 | 05-JUL-11:00 | 23131.22 | 21-JUL-16:00 | 0.00 |
August | 0.202604E+12 | 0.522961E+11 | 744.00 | 0.199890E+12 | 0.271463E+10 | 0.00 | 0.99 | 08-AUG-16:00 | 0.26 | 31-AUG-24:00 | 85518.78 | 25-AUG-18:20 | 84498.00 | 05-AUG-18:30 | 4125.82 | 31-AUG-16:00 | 30015.75 | 08-AUG-16:00 | 0.00 |
September | 0.451456E+11 | 0.115706E+11 | 720.00 | 0.445810E+11 | 0.564609E+09 | 0.00 | 0.41 | 30-SEP-23:50 | 0.12 | 23-SEP-06:55 | 34440.44 | 30-SEP-23:50 | 34440.44 | 30-SEP-23:50 | 2537.78 | 18-SEP-16:00 | 8801.52 | 01-SEP-17:00 | 0.00 |
October | 0.813543E+11 | 0.200178E+11 | 744.00 | 0.812969E+11 | 57432146.61 | 0.00 | 0.55 | 31-OCT-24:00 | 0.23 | 30-OCT-06:10 | 44888.32 | 31-OCT-24:00 | 44888.32 | 31-OCT-24:00 | 925.31 | 02-OCT-14:10 | 12357.39 | 19-OCT-16:00 | 0.00 |
November | 0.110173E+12 | 0.274379E+11 | 720.00 | 0.110121E+12 | 52119579.25 | 0.00 | 0.68 | 17-NOV-16:10 | 0.37 | 27-NOV-04:03 | 56339.68 | 17-NOV-16:10 | 56339.68 | 17-NOV-16:10 | 1893.85 | 21-NOV-12:10 | 13950.96 | 01-NOV-15:10 | 0.00 |
December | 0.143349E+12 | 0.359464E+11 | 744.00 | 0.143349E+12 | 0.00 | 0.00 | 0.81 | 08-DEC-15:50 | 0.51 | 26-DEC-07:03 | 65975.71 | 08-DEC-15:50 | 65975.71 | 08-DEC-15:50 | 0.00 | 25-DEC-21:57 | 15991.78 | 08-DEC-15:50 | 0.00 |
Annual Sum or Average | 0.123700E+13 | 0.316707E+12 | 8197.42 | 0.122843E+13 | 0.856244E+10 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.216893E+10 | 0.722976E+09 | 181.42 | 0.216893E+10 | -0.0 | 0.00 | 0.20 | 0.00 | 14788.09 | 14788.09 | 0.00 | 4063.41 | 0.00 | ||||||
Maximum of Months | 0.202604E+12 | 0.522961E+11 | 744.00 | 0.199890E+12 | 0.271526E+10 | 0.00 | 1.00 | 0.57 | 85518.78 | 84498.00 | 5067.02 | 30015.75 | 0.00 |
Report: DXReportMonthly
For: AIRLOOP DATACENTER TOP COOLING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 66495916.64 | 21588252.66 | 48.44 | 66495916.64 | -0.0 | 0.00 | 0.17 | 20-JAN-16:30 | 0.00 | 01-JAN-00:01 | 1237.03 | 20-JAN-16:30 | 1237.03 | 20-JAN-16:30 | 0.00 | 20-JAN-14:30 | 345.77 | 20-JAN-16:30 | 0.00 |
February | 0.309261E+10 | 0.869873E+09 | 628.53 | 0.309261E+10 | -0.0 | 0.00 | 0.48 | 08-FEB-17:00 | 0.00 | 01-FEB-00:03 | 3839.27 | 08-FEB-17:00 | 3839.27 | 08-FEB-17:00 | 0.00 | 09-FEB-06:04 | 966.28 | 08-FEB-17:00 | 0.00 |
March | 0.989801E+10 | 0.253040E+10 | 744.00 | 0.989801E+10 | -0.0 | 0.00 | 0.75 | 31-MAR-23:20 | 0.21 | 06-MAR-04:07 | 6426.44 | 31-MAR-23:20 | 6426.44 | 31-MAR-23:20 | 0.00 | 22-MAR-16:50 | 1519.43 | 31-MAR-23:20 | 0.00 |
April | 0.162555E+11 | 0.393943E+10 | 720.00 | 0.162555E+11 | -0.0 | 0.00 | 1.00 | 23-APR-15:51 | 0.09 | 30-APR-24:00 | 8313.66 | 21-APR-18:10 | 8313.66 | 21-APR-18:10 | 0.00 | 27-APR-12:40 | 2807.02 | 23-APR-16:00 | 0.00 |
May | 0.468971E+10 | 0.127289E+10 | 742.58 | 0.464434E+10 | 45374521.44 | 0.00 | 0.41 | 25-MAY-18:30 | 0.00 | 01-MAY-06:05 | 3290.20 | 25-MAY-18:40 | 3147.27 | 25-MAY-18:40 | 249.83 | 26-MAY-13:10 | 1105.60 | 25-MAY-18:20 | 0.00 |
June | 0.993960E+10 | 0.268288E+10 | 720.00 | 0.973964E+10 | 0.199961E+09 | 0.00 | 0.64 | 30-JUN-23:12 | 0.33 | 11-JUN-05:30 | 5799.86 | 30-JUN-24:00 | 5775.61 | 30-JUN-23:55 | 482.64 | 30-JUN-16:00 | 1992.21 | 29-JUN-16:00 | 0.00 |
July | 0.156509E+11 | 0.426285E+10 | 744.00 | 0.153797E+11 | 0.271272E+09 | 0.00 | 0.81 | 31-JUL-24:00 | 0.53 | 08-JUL-17:00 | 7409.80 | 31-JUL-23:55 | 7409.80 | 31-JUL-23:55 | 506.82 | 05-JUL-11:00 | 2347.88 | 21-JUL-16:00 | 0.00 |
August | 0.200852E+11 | 0.520548E+10 | 744.00 | 0.198140E+11 | 0.271133E+09 | 0.00 | 0.99 | 08-AUG-16:00 | 0.25 | 31-AUG-24:00 | 8624.10 | 25-AUG-18:20 | 8538.25 | 05-AUG-18:27 | 412.66 | 31-AUG-16:00 | 3039.50 | 08-AUG-16:00 | 0.00 |
September | 0.386866E+10 | 0.100600E+10 | 720.00 | 0.381335E+10 | 55310929.60 | 0.00 | 0.38 | 03-SEP-17:41 | 0.05 | 23-SEP-06:55 | 3176.07 | 03-SEP-17:43 | 3161.20 | 03-SEP-17:43 | 254.21 | 18-SEP-16:00 | 903.73 | 01-SEP-17:00 | 0.00 |
October | 0.653324E+10 | 0.163592E+10 | 743.83 | 0.652762E+10 | 5624627.46 | 0.00 | 0.52 | 19-OCT-16:40 | 0.00 | 29-OCT-21:35 | 4485.46 | 19-OCT-16:40 | 4423.81 | 19-OCT-16:40 | 92.34 | 02-OCT-14:10 | 1243.25 | 19-OCT-16:00 | 0.00 |
November | 0.901172E+10 | 0.228402E+10 | 720.00 | 0.900662E+10 | 5097549.27 | 0.00 | 0.65 | 17-NOV-16:10 | 0.24 | 27-NOV-04:03 | 5490.16 | 17-NOV-16:00 | 5490.16 | 17-NOV-16:00 | 186.89 | 21-NOV-14:10 | 1354.26 | 01-NOV-15:20 | 0.00 |
December | 0.125139E+11 | 0.318618E+10 | 744.00 | 0.125139E+11 | -0.0 | 0.00 | 0.76 | 20-DEC-15:55 | 0.39 | 25-DEC-07:50 | 6277.05 | 28-DEC-15:30 | 6277.05 | 28-DEC-15:30 | 0.00 | 17-DEC-04:27 | 1533.86 | 20-DEC-15:55 | 0.00 |
Annual Sum or Average | 0.111606E+12 | 0.288975E+11 | 8019.38 | 0.110752E+12 | 0.853774E+09 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 66495916.64 | 21588252.66 | 48.44 | 66495916.64 | -0.0 | 0.00 | 0.17 | 0.00 | 1237.03 | 1237.03 | 0.00 | 345.77 | 0.00 | ||||||
Maximum of Months | 0.200852E+11 | 0.520548E+10 | 744.00 | 0.198140E+11 | 0.271272E+09 | 0.00 | 1.00 | 0.53 | 8624.10 | 8538.25 | 506.82 | 3039.50 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 103.68 | 0.00 | 103.68 | 1.09 | 805.09 | 0.00 | 0.00 | 0.00 |
February | 159.27 | 0.00 | 159.27 | 13.92 | 648.89 | 0.00 | 0.00 | 0.00 |
March | 195.95 | 0.00 | 195.95 | 35.83 | 514.60 | 0.00 | 0.00 | 0.00 |
April | 256.93 | 2.06 | 254.87 | 123.63 | 319.21 | 0.00 | 0.00 | 0.00 |
May | 361.60 | 19.76 | 341.83 | 326.10 | 163.24 | 0.00 | 0.00 | 0.00 |
June | 403.72 | 44.84 | 358.88 | 438.31 | 112.89 | 0.00 | 0.00 | 0.00 |
July | 385.55 | 33.48 | 352.07 | 437.51 | 103.51 | 0.00 | 0.00 | 0.00 |
August | 292.62 | 5.13 | 287.49 | 301.18 | 124.62 | 0.00 | 0.00 | 0.00 |
September | 227.95 | 0.06 | 227.89 | 175.95 | 207.84 | 0.00 | 0.00 | 0.00 |
October | 158.27 | 0.00 | 158.27 | 59.04 | 332.29 | 0.00 | 0.00 | 0.00 |
November | 104.80 | 0.00 | 104.80 | 7.82 | 508.71 | 0.00 | 0.00 | 0.00 |
December | 87.85 | 0.00 | 87.85 | 0.00 | 791.11 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 228.53 | 8.82 | 219.71 | 160.94 | 384.92 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 87.85 | 0.00 | 87.85 | 0.00 | 103.51 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 403.72 | 44.84 | 358.88 | 438.31 | 805.09 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 103.68 | 0.00 | 103.68 | 1.09 | 805.10 | 0.00 | 0.00 | 0.00 |
February | 159.26 | 0.00 | 159.26 | 13.92 | 648.89 | 0.00 | 0.00 | 0.00 |
March | 195.95 | 0.00 | 195.95 | 35.82 | 514.60 | 0.00 | 0.00 | 0.00 |
April | 256.93 | 2.06 | 254.87 | 123.63 | 319.21 | 0.00 | 0.00 | 0.00 |
May | 361.59 | 19.76 | 341.83 | 326.09 | 163.24 | 0.00 | 0.00 | 0.00 |
June | 403.71 | 44.84 | 358.87 | 438.30 | 112.89 | 0.00 | 0.00 | 0.00 |
July | 385.54 | 33.48 | 352.06 | 437.50 | 103.51 | 0.00 | 0.00 | 0.00 |
August | 292.61 | 5.13 | 287.48 | 301.18 | 124.62 | 0.00 | 0.00 | 0.00 |
September | 227.94 | 0.06 | 227.89 | 175.94 | 207.84 | 0.00 | 0.00 | 0.00 |
October | 158.27 | 0.00 | 158.27 | 59.04 | 332.29 | 0.00 | 0.00 | 0.00 |
November | 104.80 | 0.00 | 104.80 | 7.82 | 508.71 | 0.00 | 0.00 | 0.00 |
December | 87.85 | 0.00 | 87.85 | 0.00 | 791.11 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 228.52 | 8.82 | 219.71 | 160.94 | 384.92 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 87.85 | 0.00 | 87.85 | 0.00 | 103.51 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 403.71 | 44.84 | 358.87 | 438.30 | 805.10 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 103.68 | 0.00 | 103.68 | 1.09 | 805.09 | 0.00 | 0.00 | 0.00 |
February | 159.26 | 0.00 | 159.26 | 13.92 | 648.89 | 0.00 | 0.00 | 0.00 |
March | 195.95 | 0.00 | 195.95 | 35.83 | 514.60 | 0.00 | 0.00 | 0.00 |
April | 256.93 | 2.06 | 254.87 | 123.63 | 319.21 | 0.00 | 0.00 | 0.00 |
May | 361.59 | 19.76 | 341.83 | 326.09 | 163.24 | 0.00 | 0.00 | 0.00 |
June | 403.71 | 44.84 | 358.88 | 438.30 | 112.89 | 0.00 | 0.00 | 0.00 |
July | 385.55 | 33.48 | 352.07 | 437.50 | 103.51 | 0.00 | 0.00 | 0.00 |
August | 292.62 | 5.13 | 287.49 | 301.18 | 124.62 | 0.00 | 0.00 | 0.00 |
September | 227.95 | 0.06 | 227.89 | 175.94 | 207.84 | 0.00 | 0.00 | 0.00 |
October | 158.27 | 0.00 | 158.27 | 59.04 | 332.29 | 0.00 | 0.00 | 0.00 |
November | 104.80 | 0.00 | 104.80 | 7.82 | 508.71 | 0.00 | 0.00 | 0.00 |
December | 87.85 | 0.00 | 87.85 | 0.00 | 791.11 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 228.52 | 8.82 | 219.71 | 160.94 | 384.92 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 87.85 | 0.00 | 87.85 | 0.00 | 103.51 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 403.71 | 44.84 | 358.88 | 438.30 | 805.09 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 103.68 | 0.00 | 103.68 | 1.09 | 805.10 | 0.00 | 0.00 | 0.00 |
February | 159.26 | 0.00 | 159.26 | 13.92 | 648.89 | 0.00 | 0.00 | 0.00 |
March | 195.95 | 0.00 | 195.95 | 35.82 | 514.60 | 0.00 | 0.00 | 0.00 |
April | 256.93 | 2.06 | 254.87 | 123.63 | 319.21 | 0.00 | 0.00 | 0.00 |
May | 361.59 | 19.76 | 341.83 | 326.09 | 163.24 | 0.00 | 0.00 | 0.00 |
June | 403.71 | 44.84 | 358.87 | 438.30 | 112.89 | 0.00 | 0.00 | 0.00 |
July | 385.54 | 33.48 | 352.06 | 437.50 | 103.51 | 0.00 | 0.00 | 0.00 |
August | 292.61 | 5.13 | 287.48 | 301.18 | 124.62 | 0.00 | 0.00 | 0.00 |
September | 227.94 | 0.06 | 227.89 | 175.94 | 207.84 | 0.00 | 0.00 | 0.00 |
October | 158.27 | 0.00 | 158.27 | 59.04 | 332.29 | 0.00 | 0.00 | 0.00 |
November | 104.80 | 0.00 | 104.80 | 7.82 | 508.71 | 0.00 | 0.00 | 0.00 |
December | 87.85 | 0.00 | 87.85 | 0.00 | 791.11 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 228.52 | 8.82 | 219.71 | 160.94 | 384.92 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 87.85 | 0.00 | 87.85 | 0.00 | 103.51 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 403.71 | 44.84 | 358.87 | 438.30 | 805.10 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 103.68 | 0.00 | 103.68 | 1.09 | 805.06 | 0.00 | 0.00 | 0.00 |
February | 159.26 | 0.00 | 159.26 | 13.92 | 648.86 | 0.00 | 0.00 | 0.00 |
March | 195.94 | 0.00 | 195.94 | 35.82 | 514.58 | 0.00 | 0.00 | 0.00 |
April | 256.92 | 2.06 | 254.86 | 123.63 | 319.20 | 0.00 | 0.00 | 0.00 |
May | 361.58 | 19.76 | 341.81 | 326.08 | 163.23 | 0.00 | 0.00 | 0.00 |
June | 403.70 | 44.84 | 358.86 | 438.28 | 112.88 | 0.00 | 0.00 | 0.00 |
July | 385.53 | 33.48 | 352.05 | 437.49 | 103.51 | 0.00 | 0.00 | 0.00 |
August | 292.60 | 5.13 | 287.47 | 301.17 | 124.61 | 0.00 | 0.00 | 0.00 |
September | 227.94 | 0.06 | 227.88 | 175.94 | 207.83 | 0.00 | 0.00 | 0.00 |
October | 158.27 | 0.00 | 158.27 | 59.03 | 332.28 | 0.00 | 0.00 | 0.00 |
November | 104.79 | 0.00 | 104.79 | 7.82 | 508.69 | 0.00 | 0.00 | 0.00 |
December | 87.84 | 0.00 | 87.84 | 0.00 | 791.08 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 228.51 | 8.82 | 219.70 | 160.93 | 384.91 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 87.84 | 0.00 | 87.84 | 0.00 | 103.51 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 403.70 | 44.84 | 358.86 | 438.28 | 805.06 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 252.96 | 105.82 | 147.14 | 105.07 | 804.16 | 0.00 | 0.00 | 0.00 |
February | 397.19 | 169.58 | 227.60 | 241.52 | 646.07 | 0.00 | 0.00 | 0.00 |
March | 540.51 | 270.99 | 269.53 | 414.91 | 516.93 | 0.00 | 0.00 | 0.00 |
April | 748.97 | 403.64 | 345.33 | 720.89 | 324.75 | 0.00 | 0.00 | 0.00 |
May | 810.80 | 356.10 | 454.70 | 887.57 | 179.75 | 0.00 | 0.00 | 0.00 |
June | 917.81 | 438.65 | 479.16 | 1088.77 | 123.57 | 0.00 | 0.00 | 0.00 |
July | 899.07 | 421.73 | 477.34 | 1094.05 | 109.26 | 0.00 | 0.00 | 0.00 |
August | 693.25 | 302.69 | 390.56 | 814.04 | 127.71 | 0.00 | 0.00 | 0.00 |
September | 555.31 | 248.39 | 306.92 | 582.27 | 215.25 | 0.00 | 0.00 | 0.00 |
October | 336.46 | 127.61 | 208.86 | 262.77 | 337.84 | 0.00 | 0.00 | 0.00 |
November | 214.40 | 71.83 | 142.57 | 104.92 | 509.94 | 0.00 | 0.00 | 0.00 |
December | 195.72 | 72.53 | 123.20 | 64.30 | 793.25 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 547.42 | 249.33 | 298.09 | 533.13 | 389.67 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 195.72 | 71.83 | 123.20 | 64.30 | 109.26 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 917.81 | 438.65 | 479.16 | 1094.05 | 804.16 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 252.96 | 105.82 | 147.14 | 105.07 | 804.16 | 0.00 | 0.00 | 0.00 |
February | 397.19 | 169.58 | 227.60 | 241.52 | 646.07 | 0.00 | 0.00 | 0.00 |
March | 540.51 | 270.99 | 269.53 | 414.91 | 516.93 | 0.00 | 0.00 | 0.00 |
April | 748.97 | 403.64 | 345.33 | 720.89 | 324.75 | 0.00 | 0.00 | 0.00 |
May | 810.80 | 356.10 | 454.70 | 887.57 | 179.75 | 0.00 | 0.00 | 0.00 |
June | 917.81 | 438.65 | 479.16 | 1088.77 | 123.57 | 0.00 | 0.00 | 0.00 |
July | 899.07 | 421.73 | 477.34 | 1094.05 | 109.26 | 0.00 | 0.00 | 0.00 |
August | 693.25 | 302.69 | 390.56 | 814.04 | 127.71 | 0.00 | 0.00 | 0.00 |
September | 555.31 | 248.39 | 306.92 | 582.27 | 215.25 | 0.00 | 0.00 | 0.00 |
October | 336.46 | 127.61 | 208.86 | 262.77 | 337.84 | 0.00 | 0.00 | 0.00 |
November | 214.40 | 71.83 | 142.57 | 104.92 | 509.94 | 0.00 | 0.00 | 0.00 |
December | 195.72 | 72.53 | 123.20 | 64.30 | 793.25 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 547.42 | 249.33 | 298.09 | 533.13 | 389.67 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 195.72 | 71.83 | 123.20 | 64.30 | 109.26 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 917.81 | 438.65 | 479.16 | 1094.05 | 804.16 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 252.96 | 105.82 | 147.14 | 105.07 | 804.15 | 0.00 | 0.00 | 0.00 |
February | 397.18 | 169.58 | 227.60 | 241.51 | 646.06 | 0.00 | 0.00 | 0.00 |
March | 540.50 | 270.98 | 269.52 | 414.90 | 516.92 | 0.00 | 0.00 | 0.00 |
April | 748.95 | 403.63 | 345.32 | 720.88 | 324.74 | 0.00 | 0.00 | 0.00 |
May | 810.78 | 356.09 | 454.69 | 887.55 | 179.75 | 0.00 | 0.00 | 0.00 |
June | 917.80 | 438.64 | 479.16 | 1088.75 | 123.57 | 0.00 | 0.00 | 0.00 |
July | 899.05 | 421.72 | 477.33 | 1094.03 | 109.25 | 0.00 | 0.00 | 0.00 |
August | 693.24 | 302.69 | 390.55 | 814.03 | 127.71 | 0.00 | 0.00 | 0.00 |
September | 555.30 | 248.38 | 306.92 | 582.26 | 215.25 | 0.00 | 0.00 | 0.00 |
October | 336.46 | 127.60 | 208.85 | 262.77 | 337.83 | 0.00 | 0.00 | 0.00 |
November | 214.40 | 71.83 | 142.57 | 104.92 | 509.93 | 0.00 | 0.00 | 0.00 |
December | 195.72 | 72.53 | 123.20 | 64.30 | 793.23 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 547.41 | 249.32 | 298.09 | 533.12 | 389.67 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 195.72 | 71.83 | 123.20 | 64.30 | 109.25 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 917.80 | 438.64 | 479.16 | 1094.03 | 804.15 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 712.14 | 494.87 | 217.27 | 613.55 | 642.56 | 0.00 | 0.00 | 0.00 |
February | 902.84 | 609.42 | 293.42 | 863.83 | 549.62 | 0.00 | 0.00 | 0.00 |
March | 797.21 | 504.76 | 292.45 | 776.57 | 461.18 | 0.00 | 0.00 | 0.00 |
April | 723.50 | 393.54 | 329.97 | 762.57 | 313.03 | 0.00 | 0.00 | 0.00 |
May | 608.53 | 209.22 | 399.31 | 694.84 | 176.30 | 0.00 | 0.00 | 0.00 |
June | 546.05 | 146.75 | 399.30 | 662.53 | 119.96 | 0.00 | 0.00 | 0.00 |
July | 597.12 | 190.47 | 406.66 | 753.82 | 108.19 | 0.00 | 0.00 | 0.00 |
August | 637.32 | 267.55 | 369.77 | 781.92 | 127.63 | 0.00 | 0.00 | 0.00 |
September | 681.87 | 363.61 | 318.26 | 779.25 | 205.22 | 0.00 | 0.00 | 0.00 |
October | 581.30 | 341.84 | 239.46 | 589.77 | 304.12 | 0.00 | 0.00 | 0.00 |
November | 516.86 | 323.98 | 192.87 | 467.14 | 430.00 | 0.00 | 0.00 | 0.00 |
December | 549.79 | 359.99 | 189.79 | 435.92 | 631.17 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 652.91 | 348.85 | 304.07 | 680.47 | 338.14 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 516.86 | 146.75 | 189.79 | 435.92 | 108.19 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 902.84 | 609.42 | 406.66 | 863.83 | 642.56 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 712.14 | 494.87 | 217.27 | 613.54 | 642.56 | 0.00 | 0.00 | 0.00 |
February | 902.84 | 609.42 | 293.42 | 863.83 | 549.62 | 0.00 | 0.00 | 0.00 |
March | 797.21 | 504.76 | 292.45 | 776.56 | 461.18 | 0.00 | 0.00 | 0.00 |
April | 723.50 | 393.53 | 329.97 | 762.57 | 313.03 | 0.00 | 0.00 | 0.00 |
May | 608.53 | 209.22 | 399.30 | 694.84 | 176.30 | 0.00 | 0.00 | 0.00 |
June | 546.05 | 146.75 | 399.30 | 662.52 | 119.96 | 0.00 | 0.00 | 0.00 |
July | 597.12 | 190.47 | 406.65 | 753.82 | 108.19 | 0.00 | 0.00 | 0.00 |
August | 637.32 | 267.55 | 369.76 | 781.91 | 127.63 | 0.00 | 0.00 | 0.00 |
September | 681.87 | 363.61 | 318.26 | 779.24 | 205.22 | 0.00 | 0.00 | 0.00 |
October | 581.30 | 341.84 | 239.46 | 589.76 | 304.12 | 0.00 | 0.00 | 0.00 |
November | 516.85 | 323.98 | 192.87 | 467.14 | 430.00 | 0.00 | 0.00 | 0.00 |
December | 549.78 | 359.99 | 189.79 | 435.91 | 631.17 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 652.91 | 348.85 | 304.06 | 680.46 | 338.14 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 516.85 | 146.75 | 189.79 | 435.91 | 108.19 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 902.84 | 609.42 | 406.65 | 863.83 | 642.56 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 712.14 | 494.87 | 217.27 | 613.55 | 642.56 | 0.00 | 0.00 | 0.00 |
February | 902.84 | 609.42 | 293.42 | 863.83 | 549.62 | 0.00 | 0.00 | 0.00 |
March | 797.21 | 504.76 | 292.45 | 776.57 | 461.18 | 0.00 | 0.00 | 0.00 |
April | 723.50 | 393.54 | 329.97 | 762.57 | 313.03 | 0.00 | 0.00 | 0.00 |
May | 608.53 | 209.22 | 399.31 | 694.84 | 176.30 | 0.00 | 0.00 | 0.00 |
June | 546.05 | 146.75 | 399.30 | 662.53 | 119.96 | 0.00 | 0.00 | 0.00 |
July | 597.12 | 190.47 | 406.66 | 753.82 | 108.19 | 0.00 | 0.00 | 0.00 |
August | 637.32 | 267.55 | 369.77 | 781.92 | 127.63 | 0.00 | 0.00 | 0.00 |
September | 681.87 | 363.61 | 318.26 | 779.25 | 205.22 | 0.00 | 0.00 | 0.00 |
October | 581.30 | 341.84 | 239.46 | 589.77 | 304.12 | 0.00 | 0.00 | 0.00 |
November | 516.86 | 323.98 | 192.87 | 467.14 | 430.00 | 0.00 | 0.00 | 0.00 |
December | 549.79 | 359.99 | 189.79 | 435.92 | 631.17 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 652.91 | 348.85 | 304.07 | 680.47 | 338.14 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 516.86 | 146.75 | 189.79 | 435.92 | 108.19 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 902.84 | 609.42 | 406.66 | 863.83 | 642.56 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 712.14 | 494.87 | 217.27 | 613.54 | 642.56 | 0.00 | 0.00 | 0.00 |
February | 902.84 | 609.42 | 293.42 | 863.83 | 549.62 | 0.00 | 0.00 | 0.00 |
March | 797.21 | 504.76 | 292.45 | 776.56 | 461.18 | 0.00 | 0.00 | 0.00 |
April | 723.50 | 393.53 | 329.97 | 762.57 | 313.03 | 0.00 | 0.00 | 0.00 |
May | 608.53 | 209.22 | 399.30 | 694.84 | 176.30 | 0.00 | 0.00 | 0.00 |
June | 546.05 | 146.75 | 399.30 | 662.52 | 119.96 | 0.00 | 0.00 | 0.00 |
July | 597.12 | 190.47 | 406.65 | 753.82 | 108.19 | 0.00 | 0.00 | 0.00 |
August | 637.32 | 267.55 | 369.76 | 781.91 | 127.63 | 0.00 | 0.00 | 0.00 |
September | 681.87 | 363.61 | 318.26 | 779.24 | 205.22 | 0.00 | 0.00 | 0.00 |
October | 581.30 | 341.84 | 239.46 | 589.76 | 304.12 | 0.00 | 0.00 | 0.00 |
November | 516.85 | 323.98 | 192.87 | 467.14 | 430.00 | 0.00 | 0.00 | 0.00 |
December | 549.78 | 359.99 | 189.79 | 435.91 | 631.17 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 652.91 | 348.85 | 304.06 | 680.46 | 338.14 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 516.85 | 146.75 | 189.79 | 435.91 | 108.19 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 902.84 | 609.42 | 406.65 | 863.83 | 642.56 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 712.11 | 494.85 | 217.26 | 613.52 | 642.54 | 0.00 | 0.00 | 0.00 |
February | 902.80 | 609.40 | 293.41 | 863.79 | 549.60 | 0.00 | 0.00 | 0.00 |
March | 797.18 | 504.74 | 292.44 | 776.53 | 461.16 | 0.00 | 0.00 | 0.00 |
April | 723.47 | 393.52 | 329.95 | 762.54 | 313.02 | 0.00 | 0.00 | 0.00 |
May | 608.50 | 209.22 | 399.29 | 694.81 | 176.30 | 0.00 | 0.00 | 0.00 |
June | 546.03 | 146.74 | 399.28 | 662.50 | 119.95 | 0.00 | 0.00 | 0.00 |
July | 597.10 | 190.46 | 406.64 | 753.79 | 108.18 | 0.00 | 0.00 | 0.00 |
August | 637.29 | 267.54 | 369.75 | 781.89 | 127.62 | 0.00 | 0.00 | 0.00 |
September | 681.84 | 363.59 | 318.25 | 779.21 | 205.21 | 0.00 | 0.00 | 0.00 |
October | 581.28 | 341.83 | 239.45 | 589.74 | 304.10 | 0.00 | 0.00 | 0.00 |
November | 516.84 | 323.97 | 192.86 | 467.12 | 429.98 | 0.00 | 0.00 | 0.00 |
December | 549.76 | 359.98 | 189.78 | 435.90 | 631.15 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 652.89 | 348.83 | 304.05 | 680.44 | 338.13 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 516.84 | 146.74 | 189.78 | 435.90 | 108.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 902.80 | 609.40 | 406.64 | 863.79 | 642.54 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 255.61 | 107.23 | 148.38 | 112.67 | 843.98 | 0.00 | 0.00 | 0.00 |
February | 416.16 | 190.20 | 225.96 | 272.95 | 700.48 | 0.00 | 0.00 | 0.00 |
March | 546.98 | 279.72 | 267.26 | 428.34 | 575.75 | 0.00 | 0.00 | 0.00 |
April | 698.49 | 353.44 | 345.05 | 651.08 | 383.59 | 0.00 | 0.00 | 0.00 |
May | 858.19 | 408.90 | 449.29 | 953.10 | 206.05 | 0.00 | 0.00 | 0.00 |
June | 828.40 | 357.87 | 470.53 | 968.53 | 146.43 | 0.00 | 0.00 | 0.00 |
July | 884.46 | 410.88 | 473.57 | 1064.27 | 136.03 | 0.00 | 0.00 | 0.00 |
August | 727.81 | 330.44 | 397.37 | 847.34 | 162.80 | 0.00 | 0.00 | 0.00 |
September | 568.75 | 255.29 | 313.47 | 597.69 | 240.41 | 0.00 | 0.00 | 0.00 |
October | 359.60 | 144.38 | 215.22 | 290.08 | 377.67 | 0.00 | 0.00 | 0.00 |
November | 218.60 | 73.85 | 144.75 | 106.66 | 566.12 | 0.00 | 0.00 | 0.00 |
December | 194.95 | 68.41 | 126.54 | 60.91 | 860.91 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 547.22 | 248.73 | 298.49 | 531.01 | 432.24 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 194.95 | 68.41 | 126.54 | 60.91 | 136.03 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 884.46 | 410.88 | 473.57 | 1064.27 | 860.91 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 255.61 | 107.23 | 148.38 | 112.67 | 843.98 | 0.00 | 0.00 | 0.00 |
February | 416.16 | 190.20 | 225.96 | 272.95 | 700.48 | 0.00 | 0.00 | 0.00 |
March | 546.98 | 279.72 | 267.26 | 428.34 | 575.75 | 0.00 | 0.00 | 0.00 |
April | 698.49 | 353.44 | 345.05 | 651.08 | 383.59 | 0.00 | 0.00 | 0.00 |
May | 858.19 | 408.90 | 449.29 | 953.10 | 206.05 | 0.00 | 0.00 | 0.00 |
June | 828.40 | 357.87 | 470.53 | 968.53 | 146.43 | 0.00 | 0.00 | 0.00 |
July | 884.46 | 410.88 | 473.57 | 1064.27 | 136.03 | 0.00 | 0.00 | 0.00 |
August | 727.81 | 330.44 | 397.37 | 847.34 | 162.80 | 0.00 | 0.00 | 0.00 |
September | 568.75 | 255.29 | 313.47 | 597.69 | 240.41 | 0.00 | 0.00 | 0.00 |
October | 359.60 | 144.38 | 215.22 | 290.08 | 377.67 | 0.00 | 0.00 | 0.00 |
November | 218.60 | 73.85 | 144.75 | 106.66 | 566.12 | 0.00 | 0.00 | 0.00 |
December | 194.95 | 68.41 | 126.54 | 60.91 | 860.91 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 547.22 | 248.73 | 298.49 | 531.01 | 432.24 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 194.95 | 68.41 | 126.54 | 60.91 | 136.03 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 884.46 | 410.88 | 473.57 | 1064.27 | 860.91 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 255.61 | 107.23 | 148.38 | 112.67 | 843.97 | 0.00 | 0.00 | 0.00 |
February | 416.15 | 190.20 | 225.95 | 272.95 | 700.47 | 0.00 | 0.00 | 0.00 |
March | 546.97 | 279.71 | 267.26 | 428.33 | 575.74 | 0.00 | 0.00 | 0.00 |
April | 698.47 | 353.43 | 345.04 | 651.07 | 383.59 | 0.00 | 0.00 | 0.00 |
May | 858.18 | 408.90 | 449.28 | 953.08 | 206.04 | 0.00 | 0.00 | 0.00 |
June | 828.39 | 357.86 | 470.53 | 968.51 | 146.42 | 0.00 | 0.00 | 0.00 |
July | 884.44 | 410.87 | 473.57 | 1064.25 | 136.03 | 0.00 | 0.00 | 0.00 |
August | 727.80 | 330.43 | 397.36 | 847.33 | 162.80 | 0.00 | 0.00 | 0.00 |
September | 568.74 | 255.28 | 313.46 | 597.68 | 240.40 | 0.00 | 0.00 | 0.00 |
October | 359.59 | 144.38 | 215.22 | 290.08 | 377.66 | 0.00 | 0.00 | 0.00 |
November | 218.60 | 73.85 | 144.75 | 106.66 | 566.11 | 0.00 | 0.00 | 0.00 |
December | 194.95 | 68.41 | 126.54 | 60.91 | 860.89 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 547.21 | 248.73 | 298.48 | 531.00 | 432.23 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 194.95 | 68.41 | 126.54 | 60.91 | 136.03 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 884.44 | 410.87 | 473.57 | 1064.25 | 860.89 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 518.42 | 0.00 | 518.42 | 12.43 | 3842.23 | 0.00 | 0.00 | 0.00 |
February | 796.33 | 0.00 | 796.33 | 99.73 | 3027.29 | 0.00 | 0.00 | 0.00 |
March | 979.74 | 0.00 | 979.74 | 217.71 | 2371.95 | 0.00 | 0.00 | 0.00 |
April | 1284.65 | 10.30 | 1274.35 | 685.89 | 1438.01 | 0.00 | 0.00 | 0.00 |
May | 1807.98 | 98.82 | 1709.16 | 1650.92 | 782.46 | 0.00 | 0.00 | 0.00 |
June | 2018.58 | 224.19 | 1794.39 | 2204.25 | 544.28 | 0.00 | 0.00 | 0.00 |
July | 1927.75 | 167.40 | 1760.35 | 2196.51 | 511.86 | 0.00 | 0.00 | 0.00 |
August | 1463.09 | 25.65 | 1437.44 | 1527.36 | 596.75 | 0.00 | 0.00 | 0.00 |
September | 1139.74 | 0.29 | 1139.45 | 905.99 | 974.18 | 0.00 | 0.00 | 0.00 |
October | 791.37 | 0.00 | 791.37 | 344.68 | 1489.66 | 0.00 | 0.00 | 0.00 |
November | 523.99 | 0.00 | 523.99 | 58.86 | 2258.17 | 0.00 | 0.00 | 0.00 |
December | 439.24 | 0.00 | 439.24 | 2.25 | 3689.99 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1142.63 | 44.09 | 1098.55 | 830.00 | 1789.14 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 439.24 | 0.00 | 439.24 | 2.25 | 511.86 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2018.58 | 224.19 | 1794.39 | 2204.25 | 3842.23 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 758.87 | 317.45 | 441.42 | 325.73 | 2315.16 | 0.00 | 0.00 | 0.00 |
February | 1191.54 | 508.75 | 682.79 | 751.05 | 1826.60 | 0.00 | 0.00 | 0.00 |
March | 1621.53 | 812.95 | 808.57 | 1263.35 | 1464.74 | 0.00 | 0.00 | 0.00 |
April | 2246.87 | 1210.89 | 1035.98 | 2176.97 | 915.12 | 0.00 | 0.00 | 0.00 |
May | 2432.37 | 1068.28 | 1364.09 | 2659.91 | 522.11 | 0.00 | 0.00 | 0.00 |
June | 2753.41 | 1315.93 | 1437.48 | 3256.92 | 365.13 | 0.00 | 0.00 | 0.00 |
July | 2697.17 | 1265.16 | 1432.01 | 3267.71 | 339.74 | 0.00 | 0.00 | 0.00 |
August | 2079.73 | 908.07 | 1171.65 | 2437.87 | 387.53 | 0.00 | 0.00 | 0.00 |
September | 1665.91 | 745.16 | 920.76 | 1757.42 | 613.34 | 0.00 | 0.00 | 0.00 |
October | 1009.38 | 382.82 | 626.57 | 813.68 | 937.39 | 0.00 | 0.00 | 0.00 |
November | 643.20 | 215.49 | 427.71 | 332.60 | 1398.31 | 0.00 | 0.00 | 0.00 |
December | 587.17 | 217.58 | 369.59 | 202.45 | 2248.73 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1642.24 | 747.98 | 894.27 | 1607.78 | 1108.44 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 587.17 | 215.49 | 369.59 | 202.45 | 339.74 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2753.41 | 1315.93 | 1437.48 | 3267.71 | 2315.16 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 3560.78 | 2474.40 | 1086.38 | 3080.99 | 3132.78 | 0.00 | 0.00 | 0.00 |
February | 4514.30 | 3047.17 | 1467.12 | 4327.49 | 2655.39 | 0.00 | 0.00 | 0.00 |
March | 3986.14 | 2523.86 | 1462.28 | 3883.44 | 2235.50 | 0.00 | 0.00 | 0.00 |
April | 3617.57 | 1967.72 | 1649.86 | 3818.28 | 1498.75 | 0.00 | 0.00 | 0.00 |
May | 3042.70 | 1046.15 | 1996.55 | 3467.00 | 863.54 | 0.00 | 0.00 | 0.00 |
June | 2730.29 | 733.76 | 1996.53 | 3313.09 | 586.09 | 0.00 | 0.00 | 0.00 |
July | 2985.65 | 952.36 | 2033.30 | 3762.42 | 545.89 | 0.00 | 0.00 | 0.00 |
August | 3186.65 | 1337.80 | 1848.86 | 3906.05 | 633.23 | 0.00 | 0.00 | 0.00 |
September | 3409.41 | 1818.08 | 1591.33 | 3887.41 | 1002.09 | 0.00 | 0.00 | 0.00 |
October | 2906.56 | 1709.24 | 1197.32 | 2958.32 | 1460.25 | 0.00 | 0.00 | 0.00 |
November | 2584.34 | 1619.96 | 964.38 | 2355.74 | 2036.19 | 0.00 | 0.00 | 0.00 |
December | 2748.98 | 1800.00 | 948.98 | 2204.43 | 3024.96 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3264.63 | 1744.29 | 1520.34 | 3406.98 | 1635.14 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 2584.34 | 733.76 | 948.98 | 2204.43 | 545.89 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 4514.30 | 3047.17 | 2033.30 | 4327.49 | 3132.78 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 766.83 | 321.68 | 445.15 | 352.48 | 2388.74 | 0.00 | 0.00 | 0.00 |
February | 1248.46 | 570.59 | 677.87 | 855.58 | 1927.12 | 0.00 | 0.00 | 0.00 |
March | 1640.92 | 839.14 | 801.78 | 1330.01 | 1550.73 | 0.00 | 0.00 | 0.00 |
April | 2095.44 | 1060.30 | 1035.14 | 2022.36 | 993.11 | 0.00 | 0.00 | 0.00 |
May | 2574.55 | 1226.70 | 1347.85 | 2880.36 | 582.08 | 0.00 | 0.00 | 0.00 |
June | 2485.18 | 1073.59 | 1411.59 | 2936.51 | 401.47 | 0.00 | 0.00 | 0.00 |
July | 2653.34 | 1232.63 | 1420.71 | 3219.01 | 384.31 | 0.00 | 0.00 | 0.00 |
August | 2183.40 | 991.31 | 1192.09 | 2583.35 | 433.90 | 0.00 | 0.00 | 0.00 |
September | 1706.25 | 765.86 | 940.39 | 1823.66 | 659.49 | 0.00 | 0.00 | 0.00 |
October | 1078.79 | 433.13 | 645.66 | 919.21 | 990.07 | 0.00 | 0.00 | 0.00 |
November | 655.80 | 221.55 | 434.25 | 356.13 | 1458.18 | 0.00 | 0.00 | 0.00 |
December | 584.85 | 205.24 | 379.61 | 201.07 | 2317.41 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1641.64 | 746.19 | 895.45 | 1627.85 | 1170.93 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 584.85 | 205.24 | 379.61 | 201.07 | 384.31 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2653.34 | 1232.63 | 1420.71 | 3219.01 | 2388.74 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 518.42 | 0.00 | 518.42 | 14.65 | 3766.83 | 0.00 | 0.00 | 0.00 |
February | 796.33 | 0.00 | 796.33 | 108.34 | 2936.24 | 0.00 | 0.00 | 0.00 |
March | 979.74 | 0.00 | 979.74 | 239.54 | 2259.20 | 0.00 | 0.00 | 0.00 |
April | 1284.65 | 10.30 | 1274.35 | 736.92 | 1327.56 | 0.00 | 0.00 | 0.00 |
May | 1807.98 | 98.82 | 1709.16 | 1686.90 | 740.99 | 0.00 | 0.00 | 0.00 |
June | 2018.58 | 224.19 | 1794.39 | 2219.57 | 522.94 | 0.00 | 0.00 | 0.00 |
July | 1927.75 | 167.40 | 1760.35 | 2202.43 | 500.84 | 0.00 | 0.00 | 0.00 |
August | 1463.09 | 25.65 | 1437.44 | 1540.89 | 573.31 | 0.00 | 0.00 | 0.00 |
September | 1139.74 | 0.29 | 1139.45 | 945.33 | 901.32 | 0.00 | 0.00 | 0.00 |
October | 791.37 | 0.00 | 791.37 | 389.37 | 1352.52 | 0.00 | 0.00 | 0.00 |
November | 523.99 | 0.00 | 523.99 | 72.32 | 2122.36 | 0.00 | 0.00 | 0.00 |
December | 439.24 | 0.00 | 439.24 | 3.75 | 3602.91 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1142.63 | 44.09 | 1098.55 | 851.13 | 1712.70 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 439.24 | 0.00 | 439.24 | 3.75 | 500.84 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2018.58 | 224.19 | 1794.39 | 2219.57 | 3766.83 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 758.87 | 317.45 | 441.42 | 330.40 | 2271.01 | 0.00 | 0.00 | 0.00 |
February | 1191.54 | 508.75 | 682.79 | 763.62 | 1771.85 | 0.00 | 0.00 | 0.00 |
March | 1621.53 | 812.95 | 808.57 | 1286.09 | 1395.34 | 0.00 | 0.00 | 0.00 |
April | 2246.87 | 1210.89 | 1035.98 | 2204.95 | 856.64 | 0.00 | 0.00 | 0.00 |
May | 2432.37 | 1068.28 | 1364.09 | 2668.82 | 502.67 | 0.00 | 0.00 | 0.00 |
June | 2753.41 | 1315.93 | 1437.48 | 3255.84 | 356.22 | 0.00 | 0.00 | 0.00 |
July | 2697.17 | 1265.16 | 1432.01 | 3263.69 | 337.52 | 0.00 | 0.00 | 0.00 |
August | 2079.73 | 908.07 | 1171.65 | 2436.91 | 380.93 | 0.00 | 0.00 | 0.00 |
September | 1665.91 | 745.16 | 920.76 | 1769.53 | 584.55 | 0.00 | 0.00 | 0.00 |
October | 1009.38 | 382.82 | 626.57 | 839.31 | 866.12 | 0.00 | 0.00 | 0.00 |
November | 643.20 | 215.49 | 427.71 | 347.73 | 1315.93 | 0.00 | 0.00 | 0.00 |
December | 587.17 | 217.58 | 369.59 | 206.66 | 2196.52 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1642.24 | 747.98 | 894.27 | 1618.39 | 1067.03 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 587.17 | 215.49 | 369.59 | 206.66 | 337.52 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2753.41 | 1315.93 | 1437.48 | 3263.69 | 2271.01 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 3560.78 | 2474.40 | 1086.38 | 3100.56 | 3058.71 | 0.00 | 0.00 | 0.00 |
February | 4514.30 | 3047.17 | 1467.12 | 4360.15 | 2555.79 | 0.00 | 0.00 | 0.00 |
March | 3986.14 | 2523.86 | 1462.28 | 3919.80 | 2122.75 | 0.00 | 0.00 | 0.00 |
April | 3617.57 | 1967.72 | 1649.86 | 3855.02 | 1399.96 | 0.00 | 0.00 | 0.00 |
May | 3042.70 | 1046.15 | 1996.55 | 3481.87 | 825.70 | 0.00 | 0.00 | 0.00 |
June | 2730.29 | 733.76 | 1996.53 | 3319.40 | 566.73 | 0.00 | 0.00 | 0.00 |
July | 2985.65 | 952.36 | 2033.30 | 3761.10 | 537.89 | 0.00 | 0.00 | 0.00 |
August | 3186.65 | 1337.80 | 1848.86 | 3907.53 | 618.32 | 0.00 | 0.00 | 0.00 |
September | 3409.41 | 1818.08 | 1591.33 | 3905.74 | 951.62 | 0.00 | 0.00 | 0.00 |
October | 2906.56 | 1709.24 | 1197.32 | 3000.54 | 1347.65 | 0.00 | 0.00 | 0.00 |
November | 2584.34 | 1619.96 | 964.38 | 2393.19 | 1905.82 | 0.00 | 0.00 | 0.00 |
December | 2748.98 | 1800.00 | 948.98 | 2227.19 | 2942.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3264.63 | 1744.29 | 1520.34 | 3429.15 | 1565.30 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 2584.34 | 733.76 | 948.98 | 2227.19 | 537.89 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 4514.30 | 3047.17 | 2033.30 | 4360.15 | 3058.71 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 766.83 | 321.68 | 445.15 | 356.21 | 2340.59 | 0.00 | 0.00 | 0.00 |
February | 1248.46 | 570.59 | 677.87 | 864.92 | 1870.77 | 0.00 | 0.00 | 0.00 |
March | 1640.92 | 839.14 | 801.78 | 1343.33 | 1483.75 | 0.00 | 0.00 | 0.00 |
April | 2095.44 | 1060.30 | 1035.14 | 2043.44 | 935.43 | 0.00 | 0.00 | 0.00 |
May | 2574.55 | 1226.70 | 1347.85 | 2888.94 | 560.91 | 0.00 | 0.00 | 0.00 |
June | 2485.18 | 1073.59 | 1411.59 | 2939.51 | 390.80 | 0.00 | 0.00 | 0.00 |
July | 2653.34 | 1232.63 | 1420.71 | 3217.48 | 379.87 | 0.00 | 0.00 | 0.00 |
August | 2183.40 | 991.31 | 1192.09 | 2585.34 | 425.00 | 0.00 | 0.00 | 0.00 |
September | 1706.25 | 765.86 | 940.39 | 1835.32 | 629.64 | 0.00 | 0.00 | 0.00 |
October | 1078.79 | 433.13 | 645.66 | 938.04 | 924.06 | 0.00 | 0.00 | 0.00 |
November | 655.80 | 221.55 | 434.25 | 368.51 | 1380.05 | 0.00 | 0.00 | 0.00 |
December | 584.85 | 205.24 | 379.61 | 204.75 | 2267.32 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1641.64 | 746.19 | 895.45 | 1636.65 | 1129.55 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 584.85 | 205.24 | 379.61 | 204.75 | 379.87 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2653.34 | 1232.63 | 1420.71 | 3217.48 | 2340.59 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.277705E+09 | 0.00 | 0.277705E+09 | 2923336.55 | 0.215636E+10 |
February | 0.385294E+09 | 0.00 | 0.385294E+09 | 33684328.02 | 0.156979E+10 |
March | 0.524828E+09 | 0.00 | 0.524828E+09 | 95957840.22 | 0.137830E+10 |
April | 0.665964E+09 | 5338443.98 | 0.660626E+09 | 0.320460E+09 | 0.827401E+09 |
May | 0.968496E+09 | 52935281.27 | 0.915561E+09 | 0.873416E+09 | 0.437227E+09 |
June | 0.104643E+10 | 0.116220E+09 | 0.930213E+09 | 0.113609E+10 | 0.292604E+09 |
July | 0.103266E+10 | 89671345.03 | 0.942984E+09 | 0.117182E+10 | 0.277244E+09 |
August | 0.783750E+09 | 13742620.64 | 0.770007E+09 | 0.806692E+09 | 0.333779E+09 |
September | 0.590840E+09 | 150704.26 | 0.590689E+09 | 0.456056E+09 | 0.538709E+09 |
October | 0.423920E+09 | 0.00 | 0.423920E+09 | 0.158128E+09 | 0.890018E+09 |
November | 0.271634E+09 | 0.00 | 0.271634E+09 | 20266434.59 | 0.131857E+10 |
December | 0.235293E+09 | 0.00 | 0.235293E+09 | 12271.84 | 0.211890E+10 |
Annual Sum or Average | 0.720681E+10 | 0.278059E+09 | 0.692875E+10 | 0.507551E+10 | 0.121389E+11 |
Minimum of Months | 0.235293E+09 | 0.00 | 0.235293E+09 | 12271.84 | 0.277244E+09 |
Maximum of Months | 0.104643E+10 | 0.116220E+09 | 0.942984E+09 | 0.117182E+10 | 0.215636E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.277700E+09 | 0.00 | 0.277700E+09 | 2922900.80 | 0.215637E+10 |
February | 0.385289E+09 | 0.00 | 0.385289E+09 | 33682076.17 | 0.156979E+10 |
March | 0.524820E+09 | 0.00 | 0.524820E+09 | 95953367.53 | 0.137831E+10 |
April | 0.665955E+09 | 5338326.62 | 0.660617E+09 | 0.320452E+09 | 0.827402E+09 |
May | 0.968482E+09 | 52934117.55 | 0.915548E+09 | 0.873399E+09 | 0.437226E+09 |
June | 0.104642E+10 | 0.116218E+09 | 0.930200E+09 | 0.113607E+10 | 0.292603E+09 |
July | 0.103264E+10 | 89669373.71 | 0.942971E+09 | 0.117180E+10 | 0.277243E+09 |
August | 0.783739E+09 | 13742318.53 | 0.769996E+09 | 0.806679E+09 | 0.333778E+09 |
September | 0.590831E+09 | 150700.95 | 0.590681E+09 | 0.456046E+09 | 0.538709E+09 |
October | 0.423913E+09 | 0.00 | 0.423913E+09 | 0.158122E+09 | 0.890018E+09 |
November | 0.271630E+09 | 0.00 | 0.271630E+09 | 20265089.95 | 0.131857E+10 |
December | 0.235290E+09 | 0.00 | 0.235290E+09 | 12260.67 | 0.211890E+10 |
Annual Sum or Average | 0.720671E+10 | 0.278052E+09 | 0.692865E+10 | 0.507541E+10 | 0.121389E+11 |
Minimum of Months | 0.235290E+09 | 0.00 | 0.235290E+09 | 12260.67 | 0.277243E+09 |
Maximum of Months | 0.104642E+10 | 0.116218E+09 | 0.942971E+09 | 0.117180E+10 | 0.215637E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.277702E+09 | 0.00 | 0.277702E+09 | 2923046.05 | 0.215637E+10 |
February | 0.385290E+09 | 0.00 | 0.385290E+09 | 33682826.79 | 0.156979E+10 |
March | 0.524823E+09 | 0.00 | 0.524823E+09 | 95954858.43 | 0.137831E+10 |
April | 0.665958E+09 | 5338365.74 | 0.660620E+09 | 0.320454E+09 | 0.827402E+09 |
May | 0.968487E+09 | 52934505.45 | 0.915552E+09 | 0.873405E+09 | 0.437226E+09 |
June | 0.104642E+10 | 0.116218E+09 | 0.930204E+09 | 0.113607E+10 | 0.292603E+09 |
July | 0.103265E+10 | 89670030.82 | 0.942975E+09 | 0.117181E+10 | 0.277243E+09 |
August | 0.783742E+09 | 13742419.23 | 0.770000E+09 | 0.806683E+09 | 0.333779E+09 |
September | 0.590834E+09 | 150702.05 | 0.590684E+09 | 0.456049E+09 | 0.538709E+09 |
October | 0.423915E+09 | 0.00 | 0.423915E+09 | 0.158124E+09 | 0.890018E+09 |
November | 0.271631E+09 | 0.00 | 0.271631E+09 | 20265538.16 | 0.131857E+10 |
December | 0.235291E+09 | 0.00 | 0.235291E+09 | 12264.39 | 0.211890E+10 |
Annual Sum or Average | 0.720674E+10 | 0.278054E+09 | 0.692869E+10 | 0.507544E+10 | 0.121389E+11 |
Minimum of Months | 0.235291E+09 | 0.00 | 0.235291E+09 | 12264.39 | 0.277243E+09 |
Maximum of Months | 0.104642E+10 | 0.116218E+09 | 0.942975E+09 | 0.117181E+10 | 0.215637E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.277700E+09 | 0.00 | 0.277700E+09 | 2922900.80 | 0.215637E+10 |
February | 0.385289E+09 | 0.00 | 0.385289E+09 | 33682076.17 | 0.156979E+10 |
March | 0.524820E+09 | 0.00 | 0.524820E+09 | 95953367.53 | 0.137831E+10 |
April | 0.665955E+09 | 5338326.62 | 0.660617E+09 | 0.320452E+09 | 0.827402E+09 |
May | 0.968482E+09 | 52934117.55 | 0.915548E+09 | 0.873399E+09 | 0.437226E+09 |
June | 0.104642E+10 | 0.116218E+09 | 0.930200E+09 | 0.113607E+10 | 0.292603E+09 |
July | 0.103264E+10 | 89669373.71 | 0.942971E+09 | 0.117180E+10 | 0.277243E+09 |
August | 0.783739E+09 | 13742318.53 | 0.769996E+09 | 0.806679E+09 | 0.333778E+09 |
September | 0.590831E+09 | 150700.95 | 0.590681E+09 | 0.456046E+09 | 0.538709E+09 |
October | 0.423913E+09 | 0.00 | 0.423913E+09 | 0.158122E+09 | 0.890018E+09 |
November | 0.271630E+09 | 0.00 | 0.271630E+09 | 20265089.95 | 0.131857E+10 |
December | 0.235290E+09 | 0.00 | 0.235290E+09 | 12260.67 | 0.211890E+10 |
Annual Sum or Average | 0.720671E+10 | 0.278052E+09 | 0.692865E+10 | 0.507541E+10 | 0.121389E+11 |
Minimum of Months | 0.235290E+09 | 0.00 | 0.235290E+09 | 12260.67 | 0.277243E+09 |
Maximum of Months | 0.104642E+10 | 0.116218E+09 | 0.942971E+09 | 0.117180E+10 | 0.215637E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.277690E+09 | 0.00 | 0.277690E+09 | 2922855.62 | 0.215628E+10 |
February | 0.385274E+09 | 0.00 | 0.385274E+09 | 33681093.93 | 0.156973E+10 |
March | 0.524800E+09 | 0.00 | 0.524800E+09 | 95950245.60 | 0.137825E+10 |
April | 0.665930E+09 | 5338131.02 | 0.660592E+09 | 0.320440E+09 | 0.827369E+09 |
May | 0.968446E+09 | 52932178.01 | 0.915513E+09 | 0.873367E+09 | 0.437209E+09 |
June | 0.104638E+10 | 0.116213E+09 | 0.930164E+09 | 0.113603E+10 | 0.292591E+09 |
July | 0.103260E+10 | 89666088.18 | 0.942935E+09 | 0.117176E+10 | 0.277232E+09 |
August | 0.783709E+09 | 13741815.00 | 0.769967E+09 | 0.806649E+09 | 0.333765E+09 |
September | 0.590809E+09 | 150695.43 | 0.590658E+09 | 0.456029E+09 | 0.538687E+09 |
October | 0.423897E+09 | 0.00 | 0.423897E+09 | 0.158117E+09 | 0.889982E+09 |
November | 0.271620E+09 | 0.00 | 0.271620E+09 | 20264497.28 | 0.131852E+10 |
December | 0.235281E+09 | 0.00 | 0.235281E+09 | 12262.04 | 0.211882E+10 |
Annual Sum or Average | 0.720643E+10 | 0.278042E+09 | 0.692839E+10 | 0.507522E+10 | 0.121384E+11 |
Minimum of Months | 0.235281E+09 | 0.00 | 0.235281E+09 | 12262.04 | 0.277232E+09 |
Maximum of Months | 0.104638E+10 | 0.116213E+09 | 0.942935E+09 | 0.117176E+10 | 0.215628E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.677528E+09 | 0.283421E+09 | 0.394107E+09 | 0.281414E+09 | 0.215387E+10 |
February | 0.960870E+09 | 0.410260E+09 | 0.550611E+09 | 0.584278E+09 | 0.156297E+10 |
March | 0.144771E+10 | 0.725812E+09 | 0.721902E+09 | 0.111130E+10 | 0.138454E+10 |
April | 0.194132E+10 | 0.104622E+10 | 0.895097E+09 | 0.186855E+10 | 0.841742E+09 |
May | 0.217165E+10 | 0.953773E+09 | 0.121787E+10 | 0.237726E+10 | 0.481447E+09 |
June | 0.237897E+10 | 0.113697E+10 | 0.124200E+10 | 0.282210E+10 | 0.320303E+09 |
July | 0.240806E+10 | 0.112955E+10 | 0.127851E+10 | 0.293031E+10 | 0.292630E+09 |
August | 0.185680E+10 | 0.810737E+09 | 0.104606E+10 | 0.218033E+10 | 0.342065E+09 |
September | 0.143936E+10 | 0.643823E+09 | 0.795542E+09 | 0.150925E+10 | 0.557933E+09 |
October | 0.901185E+09 | 0.341781E+09 | 0.559404E+09 | 0.703805E+09 | 0.904872E+09 |
November | 0.555734E+09 | 0.186189E+09 | 0.369545E+09 | 0.271964E+09 | 0.132176E+10 |
December | 0.524228E+09 | 0.194255E+09 | 0.329973E+09 | 0.172212E+09 | 0.212463E+10 |
Annual Sum or Average | 0.172634E+11 | 0.786279E+10 | 0.940062E+10 | 0.168128E+11 | 0.122888E+11 |
Minimum of Months | 0.524228E+09 | 0.186189E+09 | 0.329973E+09 | 0.172212E+09 | 0.292630E+09 |
Maximum of Months | 0.240806E+10 | 0.113697E+10 | 0.127851E+10 | 0.293031E+10 | 0.215387E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.677528E+09 | 0.283421E+09 | 0.394107E+09 | 0.281414E+09 | 0.215387E+10 |
February | 0.960870E+09 | 0.410260E+09 | 0.550611E+09 | 0.584278E+09 | 0.156297E+10 |
March | 0.144771E+10 | 0.725812E+09 | 0.721902E+09 | 0.111130E+10 | 0.138454E+10 |
April | 0.194132E+10 | 0.104622E+10 | 0.895097E+09 | 0.186855E+10 | 0.841742E+09 |
May | 0.217165E+10 | 0.953773E+09 | 0.121787E+10 | 0.237726E+10 | 0.481447E+09 |
June | 0.237897E+10 | 0.113697E+10 | 0.124200E+10 | 0.282210E+10 | 0.320303E+09 |
July | 0.240806E+10 | 0.112955E+10 | 0.127851E+10 | 0.293031E+10 | 0.292630E+09 |
August | 0.185680E+10 | 0.810737E+09 | 0.104606E+10 | 0.218033E+10 | 0.342065E+09 |
September | 0.143936E+10 | 0.643823E+09 | 0.795542E+09 | 0.150925E+10 | 0.557933E+09 |
October | 0.901185E+09 | 0.341781E+09 | 0.559404E+09 | 0.703805E+09 | 0.904872E+09 |
November | 0.555734E+09 | 0.186189E+09 | 0.369545E+09 | 0.271964E+09 | 0.132176E+10 |
December | 0.524228E+09 | 0.194255E+09 | 0.329973E+09 | 0.172212E+09 | 0.212463E+10 |
Annual Sum or Average | 0.172634E+11 | 0.786279E+10 | 0.940062E+10 | 0.168128E+11 | 0.122888E+11 |
Minimum of Months | 0.524228E+09 | 0.186189E+09 | 0.329973E+09 | 0.172212E+09 | 0.292630E+09 |
Maximum of Months | 0.240806E+10 | 0.113697E+10 | 0.127851E+10 | 0.293031E+10 | 0.215387E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.677515E+09 | 0.283416E+09 | 0.394100E+09 | 0.281409E+09 | 0.215383E+10 |
February | 0.960853E+09 | 0.410252E+09 | 0.550601E+09 | 0.584267E+09 | 0.156294E+10 |
March | 0.144769E+10 | 0.725798E+09 | 0.721889E+09 | 0.111128E+10 | 0.138451E+10 |
April | 0.194128E+10 | 0.104620E+10 | 0.895080E+09 | 0.186852E+10 | 0.841727E+09 |
May | 0.217161E+10 | 0.953755E+09 | 0.121785E+10 | 0.237721E+10 | 0.481438E+09 |
June | 0.237893E+10 | 0.113695E+10 | 0.124197E+10 | 0.282205E+10 | 0.320297E+09 |
July | 0.240801E+10 | 0.112953E+10 | 0.127849E+10 | 0.293026E+10 | 0.292625E+09 |
August | 0.185677E+10 | 0.810722E+09 | 0.104604E+10 | 0.218029E+10 | 0.342058E+09 |
September | 0.143934E+10 | 0.643811E+09 | 0.795527E+09 | 0.150923E+10 | 0.557922E+09 |
October | 0.901169E+09 | 0.341775E+09 | 0.559394E+09 | 0.703792E+09 | 0.904856E+09 |
November | 0.555724E+09 | 0.186186E+09 | 0.369538E+09 | 0.271959E+09 | 0.132174E+10 |
December | 0.524219E+09 | 0.194252E+09 | 0.329967E+09 | 0.172209E+09 | 0.212459E+10 |
Annual Sum or Average | 0.172631E+11 | 0.786265E+10 | 0.940045E+10 | 0.168125E+11 | 0.122885E+11 |
Minimum of Months | 0.524219E+09 | 0.186186E+09 | 0.329967E+09 | 0.172209E+09 | 0.292625E+09 |
Maximum of Months | 0.240801E+10 | 0.113695E+10 | 0.127849E+10 | 0.293026E+10 | 0.215383E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.190740E+10 | 0.132546E+10 | 0.581943E+09 | 0.164332E+10 | 0.172104E+10 |
February | 0.218416E+10 | 0.147431E+10 | 0.709842E+09 | 0.208979E+10 | 0.132965E+10 |
March | 0.213525E+10 | 0.135195E+10 | 0.783304E+09 | 0.207996E+10 | 0.123522E+10 |
April | 0.187532E+10 | 0.102004E+10 | 0.855276E+09 | 0.197659E+10 | 0.811368E+09 |
May | 0.162989E+10 | 0.560387E+09 | 0.106950E+10 | 0.186106E+10 | 0.472212E+09 |
June | 0.141536E+10 | 0.380375E+09 | 0.103499E+10 | 0.171727E+10 | 0.310926E+09 |
July | 0.159933E+10 | 0.510147E+09 | 0.108919E+10 | 0.201903E+10 | 0.289769E+09 |
August | 0.170700E+10 | 0.716617E+09 | 0.990383E+09 | 0.209430E+10 | 0.341844E+09 |
September | 0.176741E+10 | 0.942474E+09 | 0.824935E+09 | 0.201981E+10 | 0.531937E+09 |
October | 0.155696E+10 | 0.915588E+09 | 0.641370E+09 | 0.157964E+10 | 0.814545E+09 |
November | 0.133970E+10 | 0.839768E+09 | 0.499927E+09 | 0.121083E+10 | 0.111456E+10 |
December | 0.147254E+10 | 0.964206E+09 | 0.508339E+09 | 0.116756E+10 | 0.169053E+10 |
Annual Sum or Average | 0.205903E+11 | 0.110013E+11 | 0.958900E+10 | 0.214592E+11 | 0.106636E+11 |
Minimum of Months | 0.133970E+10 | 0.380375E+09 | 0.499927E+09 | 0.116756E+10 | 0.289769E+09 |
Maximum of Months | 0.218416E+10 | 0.147431E+10 | 0.108919E+10 | 0.209430E+10 | 0.172104E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.190739E+10 | 0.132545E+10 | 0.581940E+09 | 0.164331E+10 | 0.172104E+10 |
February | 0.218414E+10 | 0.147430E+10 | 0.709837E+09 | 0.208977E+10 | 0.132965E+10 |
March | 0.213524E+10 | 0.135194E+10 | 0.783300E+09 | 0.207994E+10 | 0.123522E+10 |
April | 0.187531E+10 | 0.102004E+10 | 0.855271E+09 | 0.197658E+10 | 0.811368E+09 |
May | 0.162988E+10 | 0.560383E+09 | 0.106950E+10 | 0.186105E+10 | 0.472212E+09 |
June | 0.141536E+10 | 0.380372E+09 | 0.103498E+10 | 0.171726E+10 | 0.310926E+09 |
July | 0.159932E+10 | 0.510143E+09 | 0.108918E+10 | 0.201902E+10 | 0.289769E+09 |
August | 0.170699E+10 | 0.716612E+09 | 0.990378E+09 | 0.209428E+10 | 0.341844E+09 |
September | 0.176740E+10 | 0.942467E+09 | 0.824931E+09 | 0.201979E+10 | 0.531936E+09 |
October | 0.155695E+10 | 0.915582E+09 | 0.641366E+09 | 0.157962E+10 | 0.814545E+09 |
November | 0.133969E+10 | 0.839762E+09 | 0.499924E+09 | 0.121082E+10 | 0.111456E+10 |
December | 0.147253E+10 | 0.964199E+09 | 0.508335E+09 | 0.116754E+10 | 0.169053E+10 |
Annual Sum or Average | 0.205902E+11 | 0.110013E+11 | 0.958894E+10 | 0.214590E+11 | 0.106636E+11 |
Minimum of Months | 0.133969E+10 | 0.380372E+09 | 0.499924E+09 | 0.116754E+10 | 0.289769E+09 |
Maximum of Months | 0.218414E+10 | 0.147430E+10 | 0.108918E+10 | 0.209428E+10 | 0.172104E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.190740E+10 | 0.132546E+10 | 0.581943E+09 | 0.164332E+10 | 0.172104E+10 |
February | 0.218416E+10 | 0.147431E+10 | 0.709842E+09 | 0.208979E+10 | 0.132965E+10 |
March | 0.213525E+10 | 0.135195E+10 | 0.783304E+09 | 0.207996E+10 | 0.123522E+10 |
April | 0.187532E+10 | 0.102004E+10 | 0.855276E+09 | 0.197659E+10 | 0.811368E+09 |
May | 0.162989E+10 | 0.560387E+09 | 0.106950E+10 | 0.186106E+10 | 0.472212E+09 |
June | 0.141536E+10 | 0.380375E+09 | 0.103499E+10 | 0.171727E+10 | 0.310926E+09 |
July | 0.159933E+10 | 0.510147E+09 | 0.108919E+10 | 0.201903E+10 | 0.289769E+09 |
August | 0.170700E+10 | 0.716617E+09 | 0.990383E+09 | 0.209430E+10 | 0.341844E+09 |
September | 0.176741E+10 | 0.942474E+09 | 0.824935E+09 | 0.201981E+10 | 0.531937E+09 |
October | 0.155696E+10 | 0.915588E+09 | 0.641370E+09 | 0.157964E+10 | 0.814545E+09 |
November | 0.133970E+10 | 0.839768E+09 | 0.499927E+09 | 0.121083E+10 | 0.111456E+10 |
December | 0.147254E+10 | 0.964206E+09 | 0.508339E+09 | 0.116756E+10 | 0.169053E+10 |
Annual Sum or Average | 0.205903E+11 | 0.110013E+11 | 0.958900E+10 | 0.214592E+11 | 0.106636E+11 |
Minimum of Months | 0.133970E+10 | 0.380375E+09 | 0.499927E+09 | 0.116756E+10 | 0.289769E+09 |
Maximum of Months | 0.218416E+10 | 0.147431E+10 | 0.108919E+10 | 0.209430E+10 | 0.172104E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.190739E+10 | 0.132545E+10 | 0.581940E+09 | 0.164331E+10 | 0.172104E+10 |
February | 0.218414E+10 | 0.147430E+10 | 0.709837E+09 | 0.208977E+10 | 0.132965E+10 |
March | 0.213524E+10 | 0.135194E+10 | 0.783300E+09 | 0.207994E+10 | 0.123522E+10 |
April | 0.187531E+10 | 0.102004E+10 | 0.855271E+09 | 0.197658E+10 | 0.811368E+09 |
May | 0.162988E+10 | 0.560383E+09 | 0.106950E+10 | 0.186105E+10 | 0.472212E+09 |
June | 0.141536E+10 | 0.380372E+09 | 0.103498E+10 | 0.171726E+10 | 0.310926E+09 |
July | 0.159932E+10 | 0.510143E+09 | 0.108918E+10 | 0.201902E+10 | 0.289769E+09 |
August | 0.170699E+10 | 0.716612E+09 | 0.990378E+09 | 0.209428E+10 | 0.341844E+09 |
September | 0.176740E+10 | 0.942467E+09 | 0.824931E+09 | 0.201979E+10 | 0.531936E+09 |
October | 0.155695E+10 | 0.915582E+09 | 0.641366E+09 | 0.157962E+10 | 0.814545E+09 |
November | 0.133969E+10 | 0.839762E+09 | 0.499924E+09 | 0.121082E+10 | 0.111456E+10 |
December | 0.147253E+10 | 0.964199E+09 | 0.508335E+09 | 0.116754E+10 | 0.169053E+10 |
Annual Sum or Average | 0.205902E+11 | 0.110013E+11 | 0.958894E+10 | 0.214590E+11 | 0.106636E+11 |
Minimum of Months | 0.133969E+10 | 0.380372E+09 | 0.499924E+09 | 0.116754E+10 | 0.289769E+09 |
Maximum of Months | 0.218414E+10 | 0.147430E+10 | 0.108918E+10 | 0.209428E+10 | 0.172104E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.190732E+10 | 0.132540E+10 | 0.581918E+09 | 0.164325E+10 | 0.172097E+10 |
February | 0.218406E+10 | 0.147425E+10 | 0.709811E+09 | 0.208969E+10 | 0.132959E+10 |
March | 0.213516E+10 | 0.135189E+10 | 0.783270E+09 | 0.207987E+10 | 0.123517E+10 |
April | 0.187524E+10 | 0.102000E+10 | 0.855239E+09 | 0.197651E+10 | 0.811335E+09 |
May | 0.162982E+10 | 0.560363E+09 | 0.106946E+10 | 0.186098E+10 | 0.472193E+09 |
June | 0.141530E+10 | 0.380358E+09 | 0.103495E+10 | 0.171720E+10 | 0.310913E+09 |
July | 0.159926E+10 | 0.510125E+09 | 0.108914E+10 | 0.201895E+10 | 0.289757E+09 |
August | 0.170693E+10 | 0.716586E+09 | 0.990341E+09 | 0.209420E+10 | 0.341830E+09 |
September | 0.176733E+10 | 0.942432E+09 | 0.824900E+09 | 0.201972E+10 | 0.531915E+09 |
October | 0.155689E+10 | 0.915548E+09 | 0.641342E+09 | 0.157957E+10 | 0.814512E+09 |
November | 0.133964E+10 | 0.839731E+09 | 0.499906E+09 | 0.121078E+10 | 0.111452E+10 |
December | 0.147248E+10 | 0.964163E+09 | 0.508317E+09 | 0.116750E+10 | 0.169046E+10 |
Annual Sum or Average | 0.205894E+11 | 0.110008E+11 | 0.958858E+10 | 0.214582E+11 | 0.106632E+11 |
Minimum of Months | 0.133964E+10 | 0.380358E+09 | 0.499906E+09 | 0.116750E+10 | 0.289757E+09 |
Maximum of Months | 0.218406E+10 | 0.147425E+10 | 0.108914E+10 | 0.209420E+10 | 0.172097E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.684629E+09 | 0.287199E+09 | 0.397430E+09 | 0.301773E+09 | 0.226053E+10 |
February | 0.100677E+10 | 0.460131E+09 | 0.546638E+09 | 0.660332E+09 | 0.169460E+10 |
March | 0.146503E+10 | 0.749193E+09 | 0.715836E+09 | 0.114726E+10 | 0.154209E+10 |
April | 0.181048E+10 | 0.916107E+09 | 0.894372E+09 | 0.168760E+10 | 0.994271E+09 |
May | 0.229858E+10 | 0.109521E+10 | 0.120337E+10 | 0.255278E+10 | 0.551880E+09 |
June | 0.214722E+10 | 0.927595E+09 | 0.121963E+10 | 0.251044E+10 | 0.379539E+09 |
July | 0.236893E+10 | 0.110051E+10 | 0.126842E+10 | 0.285054E+10 | 0.364336E+09 |
August | 0.194936E+10 | 0.885050E+09 | 0.106431E+10 | 0.226952E+10 | 0.436042E+09 |
September | 0.147421E+10 | 0.661706E+09 | 0.812506E+09 | 0.154921E+10 | 0.623131E+09 |
October | 0.963151E+09 | 0.386701E+09 | 0.576449E+09 | 0.776959E+09 | 0.101155E+10 |
November | 0.566619E+09 | 0.191419E+09 | 0.375200E+09 | 0.276470E+09 | 0.146738E+10 |
December | 0.522161E+09 | 0.183240E+09 | 0.338921E+09 | 0.163140E+09 | 0.230585E+10 |
Annual Sum or Average | 0.172571E+11 | 0.784406E+10 | 0.941308E+10 | 0.167460E+11 | 0.136312E+11 |
Minimum of Months | 0.522161E+09 | 0.183240E+09 | 0.338921E+09 | 0.163140E+09 | 0.364336E+09 |
Maximum of Months | 0.236893E+10 | 0.110051E+10 | 0.126842E+10 | 0.285054E+10 | 0.230585E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.684629E+09 | 0.287199E+09 | 0.397430E+09 | 0.301773E+09 | 0.226053E+10 |
February | 0.100677E+10 | 0.460131E+09 | 0.546638E+09 | 0.660332E+09 | 0.169460E+10 |
March | 0.146503E+10 | 0.749193E+09 | 0.715836E+09 | 0.114726E+10 | 0.154209E+10 |
April | 0.181048E+10 | 0.916107E+09 | 0.894372E+09 | 0.168760E+10 | 0.994271E+09 |
May | 0.229858E+10 | 0.109521E+10 | 0.120337E+10 | 0.255278E+10 | 0.551880E+09 |
June | 0.214722E+10 | 0.927595E+09 | 0.121963E+10 | 0.251044E+10 | 0.379539E+09 |
July | 0.236893E+10 | 0.110051E+10 | 0.126842E+10 | 0.285054E+10 | 0.364336E+09 |
August | 0.194936E+10 | 0.885050E+09 | 0.106431E+10 | 0.226952E+10 | 0.436042E+09 |
September | 0.147421E+10 | 0.661706E+09 | 0.812506E+09 | 0.154921E+10 | 0.623131E+09 |
October | 0.963151E+09 | 0.386701E+09 | 0.576449E+09 | 0.776959E+09 | 0.101155E+10 |
November | 0.566619E+09 | 0.191419E+09 | 0.375200E+09 | 0.276470E+09 | 0.146738E+10 |
December | 0.522161E+09 | 0.183240E+09 | 0.338921E+09 | 0.163140E+09 | 0.230585E+10 |
Annual Sum or Average | 0.172571E+11 | 0.784406E+10 | 0.941308E+10 | 0.167460E+11 | 0.136312E+11 |
Minimum of Months | 0.522161E+09 | 0.183240E+09 | 0.338921E+09 | 0.163140E+09 | 0.364336E+09 |
Maximum of Months | 0.236893E+10 | 0.110051E+10 | 0.126842E+10 | 0.285054E+10 | 0.230585E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.684616E+09 | 0.287194E+09 | 0.397423E+09 | 0.301768E+09 | 0.226049E+10 |
February | 0.100675E+10 | 0.460123E+09 | 0.546628E+09 | 0.660320E+09 | 0.169457E+10 |
March | 0.146500E+10 | 0.749179E+09 | 0.715823E+09 | 0.114723E+10 | 0.154206E+10 |
April | 0.181045E+10 | 0.916091E+09 | 0.894356E+09 | 0.168757E+10 | 0.994253E+09 |
May | 0.229854E+10 | 0.109519E+10 | 0.120335E+10 | 0.255273E+10 | 0.551870E+09 |
June | 0.214718E+10 | 0.927578E+09 | 0.121960E+10 | 0.251039E+10 | 0.379532E+09 |
July | 0.236888E+10 | 0.110049E+10 | 0.126840E+10 | 0.285048E+10 | 0.364330E+09 |
August | 0.194933E+10 | 0.885034E+09 | 0.106429E+10 | 0.226948E+10 | 0.436034E+09 |
September | 0.147419E+10 | 0.661694E+09 | 0.812492E+09 | 0.154918E+10 | 0.623120E+09 |
October | 0.963133E+09 | 0.386694E+09 | 0.576439E+09 | 0.776945E+09 | 0.101153E+10 |
November | 0.566608E+09 | 0.191415E+09 | 0.375193E+09 | 0.276465E+09 | 0.146735E+10 |
December | 0.522151E+09 | 0.183236E+09 | 0.338915E+09 | 0.163137E+09 | 0.230581E+10 |
Annual Sum or Average | 0.172568E+11 | 0.784391E+10 | 0.941291E+10 | 0.167457E+11 | 0.136309E+11 |
Minimum of Months | 0.522151E+09 | 0.183236E+09 | 0.338915E+09 | 0.163137E+09 | 0.364330E+09 |
Maximum of Months | 0.236888E+10 | 0.110049E+10 | 0.126840E+10 | 0.285048E+10 | 0.230581E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.138852E+10 | 0.00 | 0.138852E+10 | 33283564.97 | 0.102910E+11 |
February | 0.192647E+10 | 0.00 | 0.192647E+10 | 0.241266E+09 | 0.732361E+10 |
March | 0.262414E+10 | 0.00 | 0.262414E+10 | 0.583127E+09 | 0.635302E+10 |
April | 0.332982E+10 | 26692390.00 | 0.330313E+10 | 0.177783E+10 | 0.372732E+10 |
May | 0.484248E+10 | 0.264678E+09 | 0.457781E+10 | 0.442183E+10 | 0.209574E+10 |
June | 0.523217E+10 | 0.581104E+09 | 0.465106E+10 | 0.571340E+10 | 0.141077E+10 |
July | 0.516328E+10 | 0.448360E+09 | 0.471492E+10 | 0.588315E+10 | 0.137096E+10 |
August | 0.391875E+10 | 68713541.11 | 0.385004E+10 | 0.409088E+10 | 0.159832E+10 |
September | 0.295420E+10 | 753526.11 | 0.295345E+10 | 0.234834E+10 | 0.252508E+10 |
October | 0.211960E+10 | 0.00 | 0.211960E+10 | 0.923196E+09 | 0.398992E+10 |
November | 0.135817E+10 | 0.00 | 0.135817E+10 | 0.152562E+09 | 0.585317E+10 |
December | 0.117647E+10 | 0.00 | 0.117647E+10 | 6028013.82 | 0.988327E+10 |
Annual Sum or Average | 0.360341E+11 | 0.139030E+10 | 0.346438E+11 | 0.261749E+11 | 0.564222E+11 |
Minimum of Months | 0.117647E+10 | 0.00 | 0.117647E+10 | 6028013.82 | 0.137096E+10 |
Maximum of Months | 0.523217E+10 | 0.581104E+09 | 0.471492E+10 | 0.588315E+10 | 0.102910E+11 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.203256E+10 | 0.850253E+09 | 0.118231E+10 | 0.872448E+09 | 0.620092E+10 |
February | 0.288258E+10 | 0.123077E+10 | 0.165181E+10 | 0.181693E+10 | 0.441891E+10 |
March | 0.434310E+10 | 0.217741E+10 | 0.216569E+10 | 0.338376E+10 | 0.392316E+10 |
April | 0.582390E+10 | 0.313864E+10 | 0.268526E+10 | 0.564271E+10 | 0.237198E+10 |
May | 0.651487E+10 | 0.286129E+10 | 0.365358E+10 | 0.712429E+10 | 0.139842E+10 |
June | 0.713683E+10 | 0.341089E+10 | 0.372595E+10 | 0.844194E+10 | 0.946413E+09 |
July | 0.722410E+10 | 0.338861E+10 | 0.383549E+10 | 0.875223E+10 | 0.909965E+09 |
August | 0.557035E+10 | 0.243219E+10 | 0.313816E+10 | 0.652958E+10 | 0.103796E+10 |
September | 0.431805E+10 | 0.193145E+10 | 0.238660E+10 | 0.455524E+10 | 0.158978E+10 |
October | 0.270353E+10 | 0.102533E+10 | 0.167819E+10 | 0.217935E+10 | 0.251070E+10 |
November | 0.166719E+10 | 0.558562E+09 | 0.110862E+10 | 0.862100E+09 | 0.362442E+10 |
December | 0.157267E+10 | 0.582760E+09 | 0.989909E+09 | 0.542245E+09 | 0.602301E+10 |
Annual Sum or Average | 0.517897E+11 | 0.235881E+11 | 0.282016E+11 | 0.507028E+11 | 0.349556E+11 |
Minimum of Months | 0.157267E+10 | 0.558562E+09 | 0.989909E+09 | 0.542245E+09 | 0.909965E+09 |
Maximum of Months | 0.722410E+10 | 0.341089E+10 | 0.383549E+10 | 0.875223E+10 | 0.620092E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.953720E+10 | 0.662744E+10 | 0.290976E+10 | 0.825212E+10 | 0.839083E+10 |
February | 0.109210E+11 | 0.737172E+10 | 0.354926E+10 | 0.104691E+11 | 0.642392E+10 |
March | 0.106765E+11 | 0.675990E+10 | 0.391657E+10 | 0.104014E+11 | 0.598756E+10 |
April | 0.937675E+10 | 0.510033E+10 | 0.427643E+10 | 0.989698E+10 | 0.388476E+10 |
May | 0.814957E+10 | 0.280200E+10 | 0.534757E+10 | 0.928602E+10 | 0.231291E+10 |
June | 0.707692E+10 | 0.190191E+10 | 0.517500E+10 | 0.858752E+10 | 0.151914E+10 |
July | 0.799678E+10 | 0.255079E+10 | 0.544599E+10 | 0.100773E+11 | 0.146212E+10 |
August | 0.853514E+10 | 0.358316E+10 | 0.495198E+10 | 0.104620E+11 | 0.169605E+10 |
September | 0.883720E+10 | 0.471247E+10 | 0.412473E+10 | 0.100762E+11 | 0.259742E+10 |
October | 0.778493E+10 | 0.457804E+10 | 0.320690E+10 | 0.792356E+10 | 0.391114E+10 |
November | 0.669861E+10 | 0.419893E+10 | 0.249968E+10 | 0.610609E+10 | 0.527779E+10 |
December | 0.736287E+10 | 0.482113E+10 | 0.254174E+10 | 0.590435E+10 | 0.810204E+10 |
Annual Sum or Average | 0.102953E+12 | 0.550078E+11 | 0.479456E+11 | 0.107442E+12 | 0.515657E+11 |
Minimum of Months | 0.669861E+10 | 0.190191E+10 | 0.249968E+10 | 0.590435E+10 | 0.146212E+10 |
Maximum of Months | 0.109210E+11 | 0.737172E+10 | 0.544599E+10 | 0.104691E+11 | 0.839083E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.205387E+10 | 0.861588E+09 | 0.119228E+10 | 0.944078E+09 | 0.639800E+10 |
February | 0.302028E+10 | 0.138038E+10 | 0.163990E+10 | 0.206981E+10 | 0.466208E+10 |
March | 0.439504E+10 | 0.224756E+10 | 0.214749E+10 | 0.356231E+10 | 0.415348E+10 |
April | 0.543138E+10 | 0.274829E+10 | 0.268309E+10 | 0.524196E+10 | 0.257414E+10 |
May | 0.689567E+10 | 0.328560E+10 | 0.361007E+10 | 0.771476E+10 | 0.155904E+10 |
June | 0.644159E+10 | 0.278276E+10 | 0.365884E+10 | 0.761144E+10 | 0.104060E+10 |
July | 0.710671E+10 | 0.330148E+10 | 0.380522E+10 | 0.862180E+10 | 0.102933E+10 |
August | 0.584803E+10 | 0.265512E+10 | 0.319291E+10 | 0.691923E+10 | 0.116217E+10 |
September | 0.442259E+10 | 0.198510E+10 | 0.243749E+10 | 0.472692E+10 | 0.170940E+10 |
October | 0.288942E+10 | 0.116009E+10 | 0.172933E+10 | 0.246200E+10 | 0.265181E+10 |
November | 0.169984E+10 | 0.574250E+09 | 0.112559E+10 | 0.923088E+09 | 0.377961E+10 |
December | 0.156647E+10 | 0.549713E+09 | 0.101675E+10 | 0.538535E+09 | 0.620694E+10 |
Annual Sum or Average | 0.517709E+11 | 0.235319E+11 | 0.282390E+11 | 0.513359E+11 | 0.369266E+11 |
Minimum of Months | 0.156647E+10 | 0.549713E+09 | 0.101675E+10 | 0.538535E+09 | 0.102933E+10 |
Maximum of Months | 0.710671E+10 | 0.330148E+10 | 0.380522E+10 | 0.862180E+10 | 0.639800E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.138852E+10 | 0.00 | 0.138852E+10 | 39240950.21 | 0.100891E+11 |
February | 0.192647E+10 | 0.00 | 0.192647E+10 | 0.262107E+09 | 0.710335E+10 |
March | 0.262414E+10 | 0.00 | 0.262414E+10 | 0.641576E+09 | 0.605104E+10 |
April | 0.332982E+10 | 26692390.00 | 0.330313E+10 | 0.191010E+10 | 0.344103E+10 |
May | 0.484248E+10 | 0.264678E+09 | 0.457781E+10 | 0.451819E+10 | 0.198467E+10 |
June | 0.523217E+10 | 0.581104E+09 | 0.465106E+10 | 0.575312E+10 | 0.135545E+10 |
July | 0.516328E+10 | 0.448360E+09 | 0.471492E+10 | 0.589900E+10 | 0.134144E+10 |
August | 0.391875E+10 | 68713541.11 | 0.385004E+10 | 0.412712E+10 | 0.153556E+10 |
September | 0.295420E+10 | 753526.11 | 0.295345E+10 | 0.245031E+10 | 0.233622E+10 |
October | 0.211960E+10 | 0.00 | 0.211960E+10 | 0.104288E+10 | 0.362260E+10 |
November | 0.135817E+10 | 0.00 | 0.135817E+10 | 0.187460E+09 | 0.550116E+10 |
December | 0.117647E+10 | 0.00 | 0.117647E+10 | 10053842.61 | 0.965004E+10 |
Annual Sum or Average | 0.360341E+11 | 0.139030E+10 | 0.346438E+11 | 0.268411E+11 | 0.540116E+11 |
Minimum of Months | 0.117647E+10 | 0.00 | 0.117647E+10 | 10053842.61 | 0.134144E+10 |
Maximum of Months | 0.523217E+10 | 0.581104E+09 | 0.471492E+10 | 0.589900E+10 | 0.100891E+11 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.203256E+10 | 0.850253E+09 | 0.118231E+10 | 0.884944E+09 | 0.608267E+10 |
February | 0.288258E+10 | 0.123077E+10 | 0.165181E+10 | 0.184735E+10 | 0.428646E+10 |
March | 0.434310E+10 | 0.217741E+10 | 0.216569E+10 | 0.344465E+10 | 0.373727E+10 |
April | 0.582390E+10 | 0.313864E+10 | 0.268526E+10 | 0.571523E+10 | 0.222040E+10 |
May | 0.651487E+10 | 0.286129E+10 | 0.365358E+10 | 0.714816E+10 | 0.134635E+10 |
June | 0.713683E+10 | 0.341089E+10 | 0.372595E+10 | 0.843914E+10 | 0.923311E+09 |
July | 0.722410E+10 | 0.338861E+10 | 0.383549E+10 | 0.874148E+10 | 0.904026E+09 |
August | 0.557035E+10 | 0.243219E+10 | 0.313816E+10 | 0.652701E+10 | 0.102027E+10 |
September | 0.431805E+10 | 0.193145E+10 | 0.238660E+10 | 0.458663E+10 | 0.151516E+10 |
October | 0.270353E+10 | 0.102533E+10 | 0.167819E+10 | 0.224800E+10 | 0.231982E+10 |
November | 0.166719E+10 | 0.558562E+09 | 0.110862E+10 | 0.901311E+09 | 0.341090E+10 |
December | 0.157267E+10 | 0.582760E+09 | 0.989909E+09 | 0.553523E+09 | 0.588316E+10 |
Annual Sum or Average | 0.517897E+11 | 0.235881E+11 | 0.282016E+11 | 0.510374E+11 | 0.336498E+11 |
Minimum of Months | 0.157267E+10 | 0.558562E+09 | 0.989909E+09 | 0.553523E+09 | 0.904026E+09 |
Maximum of Months | 0.722410E+10 | 0.341089E+10 | 0.383549E+10 | 0.874148E+10 | 0.608267E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.953720E+10 | 0.662744E+10 | 0.290976E+10 | 0.830454E+10 | 0.819245E+10 |
February | 0.109210E+11 | 0.737172E+10 | 0.354926E+10 | 0.105481E+11 | 0.618296E+10 |
March | 0.106765E+11 | 0.675990E+10 | 0.391657E+10 | 0.104988E+11 | 0.568558E+10 |
April | 0.937675E+10 | 0.510033E+10 | 0.427643E+10 | 0.999220E+10 | 0.362869E+10 |
May | 0.814957E+10 | 0.280200E+10 | 0.534757E+10 | 0.932585E+10 | 0.221155E+10 |
June | 0.707692E+10 | 0.190191E+10 | 0.517500E+10 | 0.860388E+10 | 0.146897E+10 |
July | 0.799678E+10 | 0.255079E+10 | 0.544599E+10 | 0.100737E+11 | 0.144068E+10 |
August | 0.853514E+10 | 0.358316E+10 | 0.495198E+10 | 0.104659E+11 | 0.165611E+10 |
September | 0.883720E+10 | 0.471247E+10 | 0.412473E+10 | 0.101237E+11 | 0.246659E+10 |
October | 0.778493E+10 | 0.457804E+10 | 0.320690E+10 | 0.803664E+10 | 0.360956E+10 |
November | 0.669861E+10 | 0.419893E+10 | 0.249968E+10 | 0.620314E+10 | 0.493988E+10 |
December | 0.736287E+10 | 0.482113E+10 | 0.254174E+10 | 0.596531E+10 | 0.788016E+10 |
Annual Sum or Average | 0.102953E+12 | 0.550078E+11 | 0.479456E+11 | 0.108142E+12 | 0.493632E+11 |
Minimum of Months | 0.669861E+10 | 0.190191E+10 | 0.249968E+10 | 0.596531E+10 | 0.144068E+10 |
Maximum of Months | 0.109210E+11 | 0.737172E+10 | 0.544599E+10 | 0.105481E+11 | 0.819245E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.205387E+10 | 0.861588E+09 | 0.119228E+10 | 0.954074E+09 | 0.626904E+10 |
February | 0.302028E+10 | 0.138038E+10 | 0.163990E+10 | 0.209241E+10 | 0.452576E+10 |
March | 0.439504E+10 | 0.224756E+10 | 0.214749E+10 | 0.359798E+10 | 0.397409E+10 |
April | 0.543138E+10 | 0.274829E+10 | 0.268309E+10 | 0.529660E+10 | 0.242465E+10 |
May | 0.689567E+10 | 0.328560E+10 | 0.361007E+10 | 0.773774E+10 | 0.150235E+10 |
June | 0.644159E+10 | 0.278276E+10 | 0.365884E+10 | 0.761920E+10 | 0.101296E+10 |
July | 0.710671E+10 | 0.330148E+10 | 0.380522E+10 | 0.861769E+10 | 0.101744E+10 |
August | 0.584803E+10 | 0.265512E+10 | 0.319291E+10 | 0.692458E+10 | 0.113833E+10 |
September | 0.442259E+10 | 0.198510E+10 | 0.243749E+10 | 0.475715E+10 | 0.163202E+10 |
October | 0.288942E+10 | 0.116009E+10 | 0.172933E+10 | 0.251246E+10 | 0.247501E+10 |
November | 0.169984E+10 | 0.574250E+09 | 0.112559E+10 | 0.955190E+09 | 0.357709E+10 |
December | 0.156647E+10 | 0.549713E+09 | 0.101675E+10 | 0.548394E+09 | 0.607279E+10 |
Annual Sum or Average | 0.517709E+11 | 0.235319E+11 | 0.282390E+11 | 0.516135E+11 | 0.356215E+11 |
Minimum of Months | 0.156647E+10 | 0.549713E+09 | 0.101675E+10 | 0.548394E+09 | 0.101296E+10 |
Maximum of Months | 0.710671E+10 | 0.330148E+10 | 0.380522E+10 | 0.861769E+10 | 0.626904E+10 |
Report: WindowZoneSummaryMonthly
For: BASEMENT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 5.46 | 4025.44 | 518.41 | 0.00 | 518.41 | 0.00 | 0.00 |
February | 69.61 | 3244.41 | 796.31 | 0.00 | 796.31 | 0.00 | 0.00 |
March | 179.13 | 2572.98 | 979.72 | 0.00 | 979.72 | 0.00 | 0.00 |
April | 618.16 | 1596.06 | 1284.63 | 10.30 | 1274.33 | 0.00 | 0.00 |
May | 1630.45 | 816.20 | 1807.94 | 98.82 | 1709.13 | 0.00 | 0.00 |
June | 2191.48 | 564.43 | 2018.54 | 224.18 | 1794.36 | 0.00 | 0.00 |
July | 2187.50 | 517.55 | 1927.71 | 167.39 | 1760.32 | 0.00 | 0.00 |
August | 1505.89 | 623.09 | 1463.07 | 25.65 | 1437.41 | 0.00 | 0.00 |
September | 879.72 | 1039.17 | 1139.72 | 0.29 | 1139.43 | 0.00 | 0.00 |
October | 295.18 | 1661.46 | 791.35 | 0.00 | 791.35 | 0.00 | 0.00 |
November | 39.09 | 2543.52 | 523.98 | 0.00 | 523.98 | 0.00 | 0.00 |
December | 0.02 | 3955.51 | 439.23 | 0.00 | 439.23 | 0.00 | 0.00 |
Annual Sum or Average | 804.70 | 1924.60 | 1142.61 | 44.08 | 1098.53 | 0.00 | 0.00 |
Minimum of Months | 0.02 | 517.55 | 439.23 | 0.00 | 439.23 | 0.00 | 0.00 |
Maximum of Months | 2191.48 | 4025.44 | 2018.54 | 224.18 | 1794.36 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 315.20 | 2412.47 | 758.88 | 317.45 | 441.43 | 0.00 | 0.00 |
February | 724.55 | 1938.19 | 1191.55 | 508.75 | 682.80 | 0.00 | 0.00 |
March | 1244.72 | 1550.77 | 1621.53 | 812.96 | 808.58 | 0.00 | 0.00 |
April | 2162.66 | 974.23 | 2246.88 | 1210.90 | 1035.99 | 0.00 | 0.00 |
May | 2662.68 | 539.25 | 2432.38 | 1068.29 | 1364.10 | 0.00 | 0.00 |
June | 3266.30 | 370.72 | 2753.42 | 1315.93 | 1437.49 | 0.00 | 0.00 |
July | 3282.14 | 327.76 | 2697.18 | 1265.17 | 1432.01 | 0.00 | 0.00 |
August | 2442.11 | 383.13 | 2079.74 | 908.08 | 1171.66 | 0.00 | 0.00 |
September | 1746.81 | 645.75 | 1665.92 | 745.16 | 920.76 | 0.00 | 0.00 |
October | 788.31 | 1013.52 | 1009.39 | 382.82 | 626.57 | 0.00 | 0.00 |
November | 314.77 | 1529.81 | 643.21 | 215.50 | 427.71 | 0.00 | 0.00 |
December | 192.89 | 2379.72 | 587.17 | 217.58 | 369.59 | 0.00 | 0.00 |
Annual Sum or Average | 1599.38 | 1169.01 | 1642.25 | 747.98 | 894.27 | 0.00 | 0.00 |
Minimum of Months | 192.89 | 327.76 | 587.17 | 215.50 | 369.59 | 0.00 | 0.00 |
Maximum of Months | 3282.14 | 2412.47 | 2753.42 | 1315.93 | 1437.49 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 3067.69 | 3212.79 | 3560.67 | 2474.32 | 1086.35 | 0.00 | 0.00 |
February | 4319.11 | 2748.09 | 4514.16 | 3047.07 | 1467.08 | 0.00 | 0.00 |
March | 3882.79 | 2305.87 | 3986.02 | 2523.77 | 1462.25 | 0.00 | 0.00 |
April | 3812.83 | 1565.13 | 3617.47 | 1967.65 | 1649.82 | 0.00 | 0.00 |
May | 3474.16 | 881.51 | 3042.62 | 1046.11 | 1996.51 | 0.00 | 0.00 |
June | 3312.60 | 599.77 | 2730.23 | 733.74 | 1996.49 | 0.00 | 0.00 |
July | 3769.06 | 540.93 | 2985.58 | 952.32 | 2033.26 | 0.00 | 0.00 |
August | 3909.56 | 638.14 | 3186.57 | 1337.76 | 1848.81 | 0.00 | 0.00 |
September | 3896.19 | 1026.10 | 3409.32 | 1818.02 | 1591.29 | 0.00 | 0.00 |
October | 2948.81 | 1520.57 | 2906.47 | 1709.19 | 1197.29 | 0.00 | 0.00 |
November | 2335.68 | 2149.99 | 2584.26 | 1619.90 | 964.36 | 0.00 | 0.00 |
December | 2179.55 | 3155.83 | 2748.89 | 1799.95 | 948.95 | 0.00 | 0.00 |
Annual Sum or Average | 3402.29 | 1690.69 | 3264.54 | 1744.23 | 1520.31 | 0.00 | 0.00 |
Minimum of Months | 2179.55 | 540.93 | 2584.26 | 733.74 | 948.95 | 0.00 | 0.00 |
Maximum of Months | 4319.11 | 3212.79 | 4514.16 | 3047.07 | 2033.26 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 338.01 | 2531.94 | 766.83 | 321.68 | 445.15 | 0.00 | 0.00 |
February | 818.86 | 2101.42 | 1248.47 | 570.60 | 677.87 | 0.00 | 0.00 |
March | 1285.00 | 1727.24 | 1640.93 | 839.14 | 801.78 | 0.00 | 0.00 |
April | 1953.23 | 1150.77 | 2095.45 | 1060.30 | 1035.15 | 0.00 | 0.00 |
May | 2859.28 | 618.14 | 2574.56 | 1226.71 | 1347.85 | 0.00 | 0.00 |
June | 2905.58 | 439.28 | 2485.19 | 1073.60 | 1411.59 | 0.00 | 0.00 |
July | 3192.79 | 408.08 | 2653.35 | 1232.64 | 1420.71 | 0.00 | 0.00 |
August | 2542.01 | 488.40 | 2183.41 | 991.31 | 1192.10 | 0.00 | 0.00 |
September | 1793.05 | 721.21 | 1706.25 | 765.86 | 940.40 | 0.00 | 0.00 |
October | 870.24 | 1133.00 | 1078.79 | 433.13 | 645.66 | 0.00 | 0.00 |
November | 319.99 | 1698.35 | 655.80 | 221.55 | 434.26 | 0.00 | 0.00 |
December | 182.73 | 2582.70 | 584.85 | 205.24 | 379.61 | 0.00 | 0.00 |
Annual Sum or Average | 1593.03 | 1296.72 | 1641.65 | 746.20 | 895.45 | 0.00 | 0.00 |
Minimum of Months | 182.73 | 408.08 | 584.85 | 205.24 | 379.61 | 0.00 | 0.00 |
Maximum of Months | 3192.79 | 2582.70 | 2653.35 | 1232.64 | 1420.71 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 12.43 | 3842.23 | 518.42 | 0.00 | 518.42 | 0.00 | 0.00 |
February | 99.73 | 3027.29 | 796.33 | 0.00 | 796.33 | 0.00 | 0.00 |
March | 217.71 | 2371.95 | 979.74 | 0.00 | 979.74 | 0.00 | 0.00 |
April | 685.89 | 1438.01 | 1284.65 | 10.30 | 1274.35 | 0.00 | 0.00 |
May | 1650.92 | 782.46 | 1807.98 | 98.82 | 1709.16 | 0.00 | 0.00 |
June | 2204.25 | 544.28 | 2018.58 | 224.19 | 1794.39 | 0.00 | 0.00 |
July | 2196.51 | 511.86 | 1927.75 | 167.40 | 1760.35 | 0.00 | 0.00 |
August | 1527.36 | 596.75 | 1463.09 | 25.65 | 1437.44 | 0.00 | 0.00 |
September | 905.99 | 974.18 | 1139.74 | 0.29 | 1139.45 | 0.00 | 0.00 |
October | 344.68 | 1489.66 | 791.37 | 0.00 | 791.37 | 0.00 | 0.00 |
November | 58.86 | 2258.17 | 523.99 | 0.00 | 523.99 | 0.00 | 0.00 |
December | 2.25 | 3689.99 | 439.24 | 0.00 | 439.24 | 0.00 | 0.00 |
Annual Sum or Average | 830.00 | 1789.14 | 1142.63 | 44.09 | 1098.55 | 0.00 | 0.00 |
Minimum of Months | 2.25 | 511.86 | 439.24 | 0.00 | 439.24 | 0.00 | 0.00 |
Maximum of Months | 2204.25 | 3842.23 | 2018.58 | 224.19 | 1794.39 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 325.73 | 2315.16 | 758.87 | 317.45 | 441.42 | 0.00 | 0.00 |
February | 751.05 | 1826.60 | 1191.54 | 508.75 | 682.79 | 0.00 | 0.00 |
March | 1263.35 | 1464.74 | 1621.53 | 812.95 | 808.57 | 0.00 | 0.00 |
April | 2176.97 | 915.12 | 2246.87 | 1210.89 | 1035.98 | 0.00 | 0.00 |
May | 2659.91 | 522.11 | 2432.37 | 1068.28 | 1364.09 | 0.00 | 0.00 |
June | 3256.92 | 365.13 | 2753.41 | 1315.93 | 1437.48 | 0.00 | 0.00 |
July | 3267.71 | 339.74 | 2697.17 | 1265.16 | 1432.01 | 0.00 | 0.00 |
August | 2437.87 | 387.53 | 2079.73 | 908.07 | 1171.65 | 0.00 | 0.00 |
September | 1757.42 | 613.34 | 1665.91 | 745.16 | 920.76 | 0.00 | 0.00 |
October | 813.68 | 937.39 | 1009.38 | 382.82 | 626.57 | 0.00 | 0.00 |
November | 332.60 | 1398.31 | 643.20 | 215.49 | 427.71 | 0.00 | 0.00 |
December | 202.45 | 2248.73 | 587.17 | 217.58 | 369.59 | 0.00 | 0.00 |
Annual Sum or Average | 1607.78 | 1108.44 | 1642.24 | 747.98 | 894.27 | 0.00 | 0.00 |
Minimum of Months | 202.45 | 339.74 | 587.17 | 215.49 | 369.59 | 0.00 | 0.00 |
Maximum of Months | 3267.71 | 2315.16 | 2753.41 | 1315.93 | 1437.48 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 3080.99 | 3132.78 | 3560.78 | 2474.40 | 1086.38 | 0.00 | 0.00 |
February | 4327.49 | 2655.39 | 4514.30 | 3047.17 | 1467.12 | 0.00 | 0.00 |
March | 3883.44 | 2235.50 | 3986.14 | 2523.86 | 1462.28 | 0.00 | 0.00 |
April | 3818.28 | 1498.75 | 3617.57 | 1967.72 | 1649.86 | 0.00 | 0.00 |
May | 3467.00 | 863.54 | 3042.70 | 1046.15 | 1996.55 | 0.00 | 0.00 |
June | 3313.09 | 586.09 | 2730.29 | 733.76 | 1996.53 | 0.00 | 0.00 |
July | 3762.42 | 545.89 | 2985.65 | 952.36 | 2033.30 | 0.00 | 0.00 |
August | 3906.05 | 633.23 | 3186.65 | 1337.80 | 1848.86 | 0.00 | 0.00 |
September | 3887.41 | 1002.09 | 3409.41 | 1818.08 | 1591.33 | 0.00 | 0.00 |
October | 2958.32 | 1460.25 | 2906.56 | 1709.24 | 1197.32 | 0.00 | 0.00 |
November | 2355.74 | 2036.19 | 2584.34 | 1619.96 | 964.38 | 0.00 | 0.00 |
December | 2204.43 | 3024.96 | 2748.98 | 1800.00 | 948.98 | 0.00 | 0.00 |
Annual Sum or Average | 3406.98 | 1635.14 | 3264.63 | 1744.29 | 1520.34 | 0.00 | 0.00 |
Minimum of Months | 2204.43 | 545.89 | 2584.34 | 733.76 | 948.98 | 0.00 | 0.00 |
Maximum of Months | 4327.49 | 3132.78 | 4514.30 | 3047.17 | 2033.30 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 352.48 | 2388.74 | 766.83 | 321.68 | 445.15 | 0.00 | 0.00 |
February | 855.58 | 1927.12 | 1248.46 | 570.59 | 677.87 | 0.00 | 0.00 |
March | 1330.01 | 1550.73 | 1640.92 | 839.14 | 801.78 | 0.00 | 0.00 |
April | 2022.36 | 993.11 | 2095.44 | 1060.30 | 1035.14 | 0.00 | 0.00 |
May | 2880.36 | 582.08 | 2574.55 | 1226.70 | 1347.85 | 0.00 | 0.00 |
June | 2936.51 | 401.47 | 2485.18 | 1073.59 | 1411.59 | 0.00 | 0.00 |
July | 3219.01 | 384.31 | 2653.34 | 1232.63 | 1420.71 | 0.00 | 0.00 |
August | 2583.35 | 433.90 | 2183.40 | 991.31 | 1192.09 | 0.00 | 0.00 |
September | 1823.66 | 659.49 | 1706.25 | 765.86 | 940.39 | 0.00 | 0.00 |
October | 919.21 | 990.07 | 1078.79 | 433.13 | 645.66 | 0.00 | 0.00 |
November | 356.13 | 1458.18 | 655.80 | 221.55 | 434.25 | 0.00 | 0.00 |
December | 201.07 | 2317.41 | 584.85 | 205.24 | 379.61 | 0.00 | 0.00 |
Annual Sum or Average | 1627.85 | 1170.93 | 1641.64 | 746.19 | 895.45 | 0.00 | 0.00 |
Minimum of Months | 201.07 | 384.31 | 584.85 | 205.24 | 379.61 | 0.00 | 0.00 |
Maximum of Months | 3219.01 | 2388.74 | 2653.34 | 1232.63 | 1420.71 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 14.65 | 3766.83 | 518.42 | 0.00 | 518.42 | 0.00 | 0.00 |
February | 108.34 | 2936.24 | 796.33 | 0.00 | 796.33 | 0.00 | 0.00 |
March | 239.54 | 2259.20 | 979.74 | 0.00 | 979.74 | 0.00 | 0.00 |
April | 736.92 | 1327.56 | 1284.65 | 10.30 | 1274.35 | 0.00 | 0.00 |
May | 1686.90 | 740.99 | 1807.98 | 98.82 | 1709.16 | 0.00 | 0.00 |
June | 2219.57 | 522.94 | 2018.58 | 224.19 | 1794.39 | 0.00 | 0.00 |
July | 2202.43 | 500.84 | 1927.75 | 167.40 | 1760.35 | 0.00 | 0.00 |
August | 1540.89 | 573.31 | 1463.09 | 25.65 | 1437.44 | 0.00 | 0.00 |
September | 945.33 | 901.32 | 1139.74 | 0.29 | 1139.45 | 0.00 | 0.00 |
October | 389.37 | 1352.52 | 791.37 | 0.00 | 791.37 | 0.00 | 0.00 |
November | 72.32 | 2122.36 | 523.99 | 0.00 | 523.99 | 0.00 | 0.00 |
December | 3.75 | 3602.91 | 439.24 | 0.00 | 439.24 | 0.00 | 0.00 |
Annual Sum or Average | 851.13 | 1712.70 | 1142.63 | 44.09 | 1098.55 | 0.00 | 0.00 |
Minimum of Months | 3.75 | 500.84 | 439.24 | 0.00 | 439.24 | 0.00 | 0.00 |
Maximum of Months | 2219.57 | 3766.83 | 2018.58 | 224.19 | 1794.39 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 330.40 | 2271.01 | 758.87 | 317.45 | 441.42 | 0.00 | 0.00 |
February | 763.62 | 1771.85 | 1191.54 | 508.75 | 682.79 | 0.00 | 0.00 |
March | 1286.09 | 1395.34 | 1621.53 | 812.95 | 808.57 | 0.00 | 0.00 |
April | 2204.95 | 856.64 | 2246.87 | 1210.89 | 1035.98 | 0.00 | 0.00 |
May | 2668.82 | 502.67 | 2432.37 | 1068.28 | 1364.09 | 0.00 | 0.00 |
June | 3255.84 | 356.22 | 2753.41 | 1315.93 | 1437.48 | 0.00 | 0.00 |
July | 3263.69 | 337.52 | 2697.17 | 1265.16 | 1432.01 | 0.00 | 0.00 |
August | 2436.91 | 380.93 | 2079.73 | 908.07 | 1171.65 | 0.00 | 0.00 |
September | 1769.53 | 584.55 | 1665.91 | 745.16 | 920.76 | 0.00 | 0.00 |
October | 839.31 | 866.12 | 1009.38 | 382.82 | 626.57 | 0.00 | 0.00 |
November | 347.73 | 1315.93 | 643.20 | 215.49 | 427.71 | 0.00 | 0.00 |
December | 206.66 | 2196.52 | 587.17 | 217.58 | 369.59 | 0.00 | 0.00 |
Annual Sum or Average | 1618.39 | 1067.03 | 1642.24 | 747.98 | 894.27 | 0.00 | 0.00 |
Minimum of Months | 206.66 | 337.52 | 587.17 | 215.49 | 369.59 | 0.00 | 0.00 |
Maximum of Months | 3263.69 | 2271.01 | 2753.41 | 1315.93 | 1437.48 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 3100.56 | 3058.71 | 3560.78 | 2474.40 | 1086.38 | 0.00 | 0.00 |
February | 4360.15 | 2555.79 | 4514.30 | 3047.17 | 1467.12 | 0.00 | 0.00 |
March | 3919.80 | 2122.75 | 3986.14 | 2523.86 | 1462.28 | 0.00 | 0.00 |
April | 3855.02 | 1399.96 | 3617.57 | 1967.72 | 1649.86 | 0.00 | 0.00 |
May | 3481.87 | 825.70 | 3042.70 | 1046.15 | 1996.55 | 0.00 | 0.00 |
June | 3319.40 | 566.73 | 2730.29 | 733.76 | 1996.53 | 0.00 | 0.00 |
July | 3761.10 | 537.89 | 2985.65 | 952.36 | 2033.30 | 0.00 | 0.00 |
August | 3907.53 | 618.32 | 3186.65 | 1337.80 | 1848.86 | 0.00 | 0.00 |
September | 3905.74 | 951.62 | 3409.41 | 1818.08 | 1591.33 | 0.00 | 0.00 |
October | 3000.54 | 1347.65 | 2906.56 | 1709.24 | 1197.32 | 0.00 | 0.00 |
November | 2393.19 | 1905.82 | 2584.34 | 1619.96 | 964.38 | 0.00 | 0.00 |
December | 2227.19 | 2942.12 | 2748.98 | 1800.00 | 948.98 | 0.00 | 0.00 |
Annual Sum or Average | 3429.15 | 1565.30 | 3264.63 | 1744.29 | 1520.34 | 0.00 | 0.00 |
Minimum of Months | 2227.19 | 537.89 | 2584.34 | 733.76 | 948.98 | 0.00 | 0.00 |
Maximum of Months | 4360.15 | 3058.71 | 4514.30 | 3047.17 | 2033.30 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 356.21 | 2340.59 | 766.83 | 321.68 | 445.15 | 0.00 | 0.00 |
February | 864.92 | 1870.77 | 1248.46 | 570.59 | 677.87 | 0.00 | 0.00 |
March | 1343.33 | 1483.75 | 1640.92 | 839.14 | 801.78 | 0.00 | 0.00 |
April | 2043.44 | 935.43 | 2095.44 | 1060.30 | 1035.14 | 0.00 | 0.00 |
May | 2888.94 | 560.91 | 2574.55 | 1226.70 | 1347.85 | 0.00 | 0.00 |
June | 2939.51 | 390.80 | 2485.18 | 1073.59 | 1411.59 | 0.00 | 0.00 |
July | 3217.48 | 379.87 | 2653.34 | 1232.63 | 1420.71 | 0.00 | 0.00 |
August | 2585.34 | 425.00 | 2183.40 | 991.31 | 1192.09 | 0.00 | 0.00 |
September | 1835.32 | 629.64 | 1706.25 | 765.86 | 940.39 | 0.00 | 0.00 |
October | 938.04 | 924.06 | 1078.79 | 433.13 | 645.66 | 0.00 | 0.00 |
November | 368.51 | 1380.05 | 655.80 | 221.55 | 434.25 | 0.00 | 0.00 |
December | 204.75 | 2267.32 | 584.85 | 205.24 | 379.61 | 0.00 | 0.00 |
Annual Sum or Average | 1636.65 | 1129.55 | 1641.64 | 746.19 | 895.45 | 0.00 | 0.00 |
Minimum of Months | 204.75 | 379.87 | 584.85 | 205.24 | 379.61 | 0.00 | 0.00 |
Maximum of Months | 3217.48 | 2340.59 | 2653.34 | 1232.63 | 1420.71 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: GROUNDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: DATACENTER_BOT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: DATACENTER_MID_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: DATACENTER_TOP_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: DATACENTER_BASEMENT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BASEMENT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 14615039.83 | 0.107817E+11 | 0.138850E+10 | 0.00 | 0.138850E+10 | 0.00 | 0.00 |
February | 0.168412E+09 | 0.784888E+10 | 0.192644E+10 | 0.00 | 0.192644E+10 | 0.00 | 0.00 |
March | 0.479770E+09 | 0.689148E+10 | 0.262409E+10 | 0.00 | 0.262409E+10 | 0.00 | 0.00 |
April | 0.160226E+10 | 0.413698E+10 | 0.332976E+10 | 26691593.98 | 0.330307E+10 | 0.00 | 0.00 |
May | 0.436698E+10 | 0.218611E+10 | 0.484239E+10 | 0.264670E+09 | 0.457772E+10 | 0.00 | 0.00 |
June | 0.568032E+10 | 0.146300E+10 | 0.523207E+10 | 0.581087E+09 | 0.465098E+10 | 0.00 | 0.00 |
July | 0.585901E+10 | 0.138621E+10 | 0.516318E+10 | 0.448346E+09 | 0.471484E+10 | 0.00 | 0.00 |
August | 0.403338E+10 | 0.166888E+10 | 0.391868E+10 | 68711491.94 | 0.384997E+10 | 0.00 | 0.00 |
September | 0.228023E+10 | 0.269352E+10 | 0.295415E+10 | 753503.64 | 0.295339E+10 | 0.00 | 0.00 |
October | 0.790613E+09 | 0.445005E+10 | 0.211956E+10 | 0.00 | 0.211956E+10 | 0.00 | 0.00 |
November | 0.101327E+09 | 0.659281E+10 | 0.135814E+10 | 0.00 | 0.135814E+10 | 0.00 | 0.00 |
December | 61319.60 | 0.105944E+11 | 0.117644E+10 | 0.00 | 0.117644E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.253770E+11 | 0.606941E+11 | 0.360334E+11 | 0.139026E+10 | 0.346431E+11 | 0.00 | 0.00 |
Minimum of Months | 61319.60 | 0.138621E+10 | 0.117644E+10 | 0.00 | 0.117644E+10 | 0.00 | 0.00 |
Maximum of Months | 0.585901E+10 | 0.107817E+11 | 0.523207E+10 | 0.581087E+09 | 0.471484E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.844238E+09 | 0.646157E+10 | 0.203257E+10 | 0.850257E+09 | 0.118231E+10 | 0.00 | 0.00 |
February | 0.175282E+10 | 0.468887E+10 | 0.288259E+10 | 0.123077E+10 | 0.165182E+10 | 0.00 | 0.00 |
March | 0.333387E+10 | 0.415359E+10 | 0.434312E+10 | 0.217742E+10 | 0.216569E+10 | 0.00 | 0.00 |
April | 0.560562E+10 | 0.252521E+10 | 0.582392E+10 | 0.313865E+10 | 0.268527E+10 | 0.00 | 0.00 |
May | 0.713173E+10 | 0.144433E+10 | 0.651490E+10 | 0.286130E+10 | 0.365360E+10 | 0.00 | 0.00 |
June | 0.846625E+10 | 0.960904E+09 | 0.713686E+10 | 0.341090E+10 | 0.372596E+10 | 0.00 | 0.00 |
July | 0.879088E+10 | 0.877886E+09 | 0.722413E+10 | 0.338862E+10 | 0.383550E+10 | 0.00 | 0.00 |
August | 0.654094E+10 | 0.102619E+10 | 0.557037E+10 | 0.243220E+10 | 0.313817E+10 | 0.00 | 0.00 |
September | 0.452773E+10 | 0.167379E+10 | 0.431807E+10 | 0.193146E+10 | 0.238661E+10 | 0.00 | 0.00 |
October | 0.211140E+10 | 0.271460E+10 | 0.270354E+10 | 0.102534E+10 | 0.167820E+10 | 0.00 | 0.00 |
November | 0.815887E+09 | 0.396527E+10 | 0.166719E+10 | 0.558564E+09 | 0.110863E+10 | 0.00 | 0.00 |
December | 0.516634E+09 | 0.637384E+10 | 0.157267E+10 | 0.582762E+09 | 0.989913E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.504380E+11 | 0.368660E+11 | 0.517899E+11 | 0.235882E+11 | 0.282017E+11 | 0.00 | 0.00 |
Minimum of Months | 0.516634E+09 | 0.877886E+09 | 0.157267E+10 | 0.558564E+09 | 0.989913E+09 | 0.00 | 0.00 |
Maximum of Months | 0.879088E+10 | 0.646157E+10 | 0.722413E+10 | 0.341090E+10 | 0.383550E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.821651E+10 | 0.860514E+10 | 0.953690E+10 | 0.662722E+10 | 0.290968E+10 | 0.00 | 0.00 |
February | 0.104488E+11 | 0.664818E+10 | 0.109207E+11 | 0.737148E+10 | 0.354917E+10 | 0.00 | 0.00 |
March | 0.103997E+11 | 0.617605E+10 | 0.106762E+11 | 0.675967E+10 | 0.391648E+10 | 0.00 | 0.00 |
April | 0.988285E+10 | 0.405681E+10 | 0.937649E+10 | 0.510016E+10 | 0.427633E+10 | 0.00 | 0.00 |
May | 0.930520E+10 | 0.236104E+10 | 0.814936E+10 | 0.280190E+10 | 0.534745E+10 | 0.00 | 0.00 |
June | 0.858625E+10 | 0.155462E+10 | 0.707674E+10 | 0.190185E+10 | 0.517489E+10 | 0.00 | 0.00 |
July | 0.100951E+11 | 0.144883E+10 | 0.799658E+10 | 0.255071E+10 | 0.544587E+10 | 0.00 | 0.00 |
August | 0.104714E+11 | 0.170921E+10 | 0.853491E+10 | 0.358304E+10 | 0.495186E+10 | 0.00 | 0.00 |
September | 0.100989E+11 | 0.265966E+10 | 0.883695E+10 | 0.471231E+10 | 0.412463E+10 | 0.00 | 0.00 |
October | 0.789808E+10 | 0.407269E+10 | 0.778470E+10 | 0.457789E+10 | 0.320681E+10 | 0.00 | 0.00 |
November | 0.605407E+10 | 0.557277E+10 | 0.669840E+10 | 0.419879E+10 | 0.249961E+10 | 0.00 | 0.00 |
December | 0.583771E+10 | 0.845258E+10 | 0.736264E+10 | 0.482097E+10 | 0.254166E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.107294E+12 | 0.533176E+11 | 0.102950E+12 | 0.550060E+11 | 0.479445E+11 | 0.00 | 0.00 |
Minimum of Months | 0.583771E+10 | 0.144883E+10 | 0.669840E+10 | 0.190185E+10 | 0.249961E+10 | 0.00 | 0.00 |
Maximum of Months | 0.104714E+11 | 0.860514E+10 | 0.109207E+11 | 0.737148E+10 | 0.544587E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.905314E+09 | 0.678154E+10 | 0.205387E+10 | 0.861592E+09 | 0.119228E+10 | 0.00 | 0.00 |
February | 0.198098E+10 | 0.508376E+10 | 0.302029E+10 | 0.138038E+10 | 0.163990E+10 | 0.00 | 0.00 |
March | 0.344174E+10 | 0.462624E+10 | 0.439506E+10 | 0.224756E+10 | 0.214749E+10 | 0.00 | 0.00 |
April | 0.506278E+10 | 0.298280E+10 | 0.543141E+10 | 0.274831E+10 | 0.268310E+10 | 0.00 | 0.00 |
May | 0.765829E+10 | 0.165563E+10 | 0.689569E+10 | 0.328561E+10 | 0.361009E+10 | 0.00 | 0.00 |
June | 0.753126E+10 | 0.113861E+10 | 0.644162E+10 | 0.278277E+10 | 0.365885E+10 | 0.00 | 0.00 |
July | 0.855156E+10 | 0.109300E+10 | 0.710674E+10 | 0.330150E+10 | 0.380524E+10 | 0.00 | 0.00 |
August | 0.680852E+10 | 0.130812E+10 | 0.584805E+10 | 0.265513E+10 | 0.319292E+10 | 0.00 | 0.00 |
September | 0.464760E+10 | 0.186938E+10 | 0.442261E+10 | 0.198511E+10 | 0.243750E+10 | 0.00 | 0.00 |
October | 0.233086E+10 | 0.303462E+10 | 0.288943E+10 | 0.116010E+10 | 0.172934E+10 | 0.00 | 0.00 |
November | 0.829405E+09 | 0.440211E+10 | 0.169985E+10 | 0.574252E+09 | 0.112559E+10 | 0.00 | 0.00 |
December | 0.489418E+09 | 0.691751E+10 | 0.156647E+10 | 0.549716E+09 | 0.101676E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.502377E+11 | 0.408933E+11 | 0.517711E+11 | 0.235320E+11 | 0.282391E+11 | 0.00 | 0.00 |
Minimum of Months | 0.489418E+09 | 0.109300E+10 | 0.156647E+10 | 0.549716E+09 | 0.101676E+10 | 0.00 | 0.00 |
Maximum of Months | 0.855156E+10 | 0.691751E+10 | 0.710674E+10 | 0.330150E+10 | 0.380524E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 33283564.97 | 0.102910E+11 | 0.138852E+10 | 0.00 | 0.138852E+10 | 0.00 | 0.00 |
February | 0.241266E+09 | 0.732361E+10 | 0.192647E+10 | 0.00 | 0.192647E+10 | 0.00 | 0.00 |
March | 0.583127E+09 | 0.635302E+10 | 0.262414E+10 | 0.00 | 0.262414E+10 | 0.00 | 0.00 |
April | 0.177783E+10 | 0.372732E+10 | 0.332982E+10 | 26692390.00 | 0.330313E+10 | 0.00 | 0.00 |
May | 0.442183E+10 | 0.209574E+10 | 0.484248E+10 | 0.264678E+09 | 0.457781E+10 | 0.00 | 0.00 |
June | 0.571340E+10 | 0.141077E+10 | 0.523217E+10 | 0.581104E+09 | 0.465106E+10 | 0.00 | 0.00 |
July | 0.588315E+10 | 0.137096E+10 | 0.516328E+10 | 0.448360E+09 | 0.471492E+10 | 0.00 | 0.00 |
August | 0.409088E+10 | 0.159832E+10 | 0.391875E+10 | 68713541.11 | 0.385004E+10 | 0.00 | 0.00 |
September | 0.234834E+10 | 0.252508E+10 | 0.295420E+10 | 753526.11 | 0.295345E+10 | 0.00 | 0.00 |
October | 0.923196E+09 | 0.398992E+10 | 0.211960E+10 | 0.00 | 0.211960E+10 | 0.00 | 0.00 |
November | 0.152562E+09 | 0.585317E+10 | 0.135817E+10 | 0.00 | 0.135817E+10 | 0.00 | 0.00 |
December | 6028013.82 | 0.988327E+10 | 0.117647E+10 | 0.00 | 0.117647E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.261749E+11 | 0.564222E+11 | 0.360341E+11 | 0.139030E+10 | 0.346438E+11 | 0.00 | 0.00 |
Minimum of Months | 6028013.82 | 0.137096E+10 | 0.117647E+10 | 0.00 | 0.117647E+10 | 0.00 | 0.00 |
Maximum of Months | 0.588315E+10 | 0.102910E+11 | 0.523217E+10 | 0.581104E+09 | 0.471492E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.872448E+09 | 0.620092E+10 | 0.203256E+10 | 0.850253E+09 | 0.118231E+10 | 0.00 | 0.00 |
February | 0.181693E+10 | 0.441891E+10 | 0.288258E+10 | 0.123077E+10 | 0.165181E+10 | 0.00 | 0.00 |
March | 0.338376E+10 | 0.392316E+10 | 0.434310E+10 | 0.217741E+10 | 0.216569E+10 | 0.00 | 0.00 |
April | 0.564271E+10 | 0.237198E+10 | 0.582390E+10 | 0.313864E+10 | 0.268526E+10 | 0.00 | 0.00 |
May | 0.712429E+10 | 0.139842E+10 | 0.651487E+10 | 0.286129E+10 | 0.365358E+10 | 0.00 | 0.00 |
June | 0.844194E+10 | 0.946413E+09 | 0.713683E+10 | 0.341089E+10 | 0.372595E+10 | 0.00 | 0.00 |
July | 0.875223E+10 | 0.909965E+09 | 0.722410E+10 | 0.338861E+10 | 0.383549E+10 | 0.00 | 0.00 |
August | 0.652958E+10 | 0.103796E+10 | 0.557035E+10 | 0.243219E+10 | 0.313816E+10 | 0.00 | 0.00 |
September | 0.455524E+10 | 0.158978E+10 | 0.431805E+10 | 0.193145E+10 | 0.238660E+10 | 0.00 | 0.00 |
October | 0.217935E+10 | 0.251070E+10 | 0.270353E+10 | 0.102533E+10 | 0.167819E+10 | 0.00 | 0.00 |
November | 0.862100E+09 | 0.362442E+10 | 0.166719E+10 | 0.558562E+09 | 0.110862E+10 | 0.00 | 0.00 |
December | 0.542245E+09 | 0.602301E+10 | 0.157267E+10 | 0.582760E+09 | 0.989909E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.507028E+11 | 0.349556E+11 | 0.517897E+11 | 0.235881E+11 | 0.282016E+11 | 0.00 | 0.00 |
Minimum of Months | 0.542245E+09 | 0.909965E+09 | 0.157267E+10 | 0.558562E+09 | 0.989909E+09 | 0.00 | 0.00 |
Maximum of Months | 0.875223E+10 | 0.620092E+10 | 0.722410E+10 | 0.341089E+10 | 0.383549E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.825212E+10 | 0.839083E+10 | 0.953720E+10 | 0.662744E+10 | 0.290976E+10 | 0.00 | 0.00 |
February | 0.104691E+11 | 0.642392E+10 | 0.109210E+11 | 0.737172E+10 | 0.354926E+10 | 0.00 | 0.00 |
March | 0.104014E+11 | 0.598756E+10 | 0.106765E+11 | 0.675990E+10 | 0.391657E+10 | 0.00 | 0.00 |
April | 0.989698E+10 | 0.388476E+10 | 0.937675E+10 | 0.510033E+10 | 0.427643E+10 | 0.00 | 0.00 |
May | 0.928602E+10 | 0.231291E+10 | 0.814957E+10 | 0.280200E+10 | 0.534757E+10 | 0.00 | 0.00 |
June | 0.858752E+10 | 0.151914E+10 | 0.707692E+10 | 0.190191E+10 | 0.517500E+10 | 0.00 | 0.00 |
July | 0.100773E+11 | 0.146212E+10 | 0.799678E+10 | 0.255079E+10 | 0.544599E+10 | 0.00 | 0.00 |
August | 0.104620E+11 | 0.169605E+10 | 0.853514E+10 | 0.358316E+10 | 0.495198E+10 | 0.00 | 0.00 |
September | 0.100762E+11 | 0.259742E+10 | 0.883720E+10 | 0.471247E+10 | 0.412473E+10 | 0.00 | 0.00 |
October | 0.792356E+10 | 0.391114E+10 | 0.778493E+10 | 0.457804E+10 | 0.320690E+10 | 0.00 | 0.00 |
November | 0.610609E+10 | 0.527779E+10 | 0.669861E+10 | 0.419893E+10 | 0.249968E+10 | 0.00 | 0.00 |
December | 0.590435E+10 | 0.810204E+10 | 0.736287E+10 | 0.482113E+10 | 0.254174E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.107442E+12 | 0.515657E+11 | 0.102953E+12 | 0.550078E+11 | 0.479456E+11 | 0.00 | 0.00 |
Minimum of Months | 0.590435E+10 | 0.146212E+10 | 0.669861E+10 | 0.190191E+10 | 0.249968E+10 | 0.00 | 0.00 |
Maximum of Months | 0.104691E+11 | 0.839083E+10 | 0.109210E+11 | 0.737172E+10 | 0.544599E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.944078E+09 | 0.639800E+10 | 0.205387E+10 | 0.861588E+09 | 0.119228E+10 | 0.00 | 0.00 |
February | 0.206981E+10 | 0.466208E+10 | 0.302028E+10 | 0.138038E+10 | 0.163990E+10 | 0.00 | 0.00 |
March | 0.356231E+10 | 0.415348E+10 | 0.439504E+10 | 0.224756E+10 | 0.214749E+10 | 0.00 | 0.00 |
April | 0.524196E+10 | 0.257414E+10 | 0.543138E+10 | 0.274829E+10 | 0.268309E+10 | 0.00 | 0.00 |
May | 0.771476E+10 | 0.155904E+10 | 0.689567E+10 | 0.328560E+10 | 0.361007E+10 | 0.00 | 0.00 |
June | 0.761144E+10 | 0.104060E+10 | 0.644159E+10 | 0.278276E+10 | 0.365884E+10 | 0.00 | 0.00 |
July | 0.862180E+10 | 0.102933E+10 | 0.710671E+10 | 0.330148E+10 | 0.380522E+10 | 0.00 | 0.00 |
August | 0.691923E+10 | 0.116217E+10 | 0.584803E+10 | 0.265512E+10 | 0.319291E+10 | 0.00 | 0.00 |
September | 0.472692E+10 | 0.170940E+10 | 0.442259E+10 | 0.198510E+10 | 0.243749E+10 | 0.00 | 0.00 |
October | 0.246200E+10 | 0.265181E+10 | 0.288942E+10 | 0.116009E+10 | 0.172933E+10 | 0.00 | 0.00 |
November | 0.923088E+09 | 0.377961E+10 | 0.169984E+10 | 0.574250E+09 | 0.112559E+10 | 0.00 | 0.00 |
December | 0.538535E+09 | 0.620694E+10 | 0.156647E+10 | 0.549713E+09 | 0.101675E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.513359E+11 | 0.369266E+11 | 0.517709E+11 | 0.235319E+11 | 0.282390E+11 | 0.00 | 0.00 |
Minimum of Months | 0.538535E+09 | 0.102933E+10 | 0.156647E+10 | 0.549713E+09 | 0.101675E+10 | 0.00 | 0.00 |
Maximum of Months | 0.862180E+10 | 0.639800E+10 | 0.710671E+10 | 0.330148E+10 | 0.380522E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 39240950.21 | 0.100891E+11 | 0.138852E+10 | 0.00 | 0.138852E+10 | 0.00 | 0.00 |
February | 0.262107E+09 | 0.710335E+10 | 0.192647E+10 | 0.00 | 0.192647E+10 | 0.00 | 0.00 |
March | 0.641576E+09 | 0.605104E+10 | 0.262414E+10 | 0.00 | 0.262414E+10 | 0.00 | 0.00 |
April | 0.191010E+10 | 0.344103E+10 | 0.332982E+10 | 26692390.00 | 0.330313E+10 | 0.00 | 0.00 |
May | 0.451819E+10 | 0.198467E+10 | 0.484248E+10 | 0.264678E+09 | 0.457781E+10 | 0.00 | 0.00 |
June | 0.575312E+10 | 0.135545E+10 | 0.523217E+10 | 0.581104E+09 | 0.465106E+10 | 0.00 | 0.00 |
July | 0.589900E+10 | 0.134144E+10 | 0.516328E+10 | 0.448360E+09 | 0.471492E+10 | 0.00 | 0.00 |
August | 0.412712E+10 | 0.153556E+10 | 0.391875E+10 | 68713541.11 | 0.385004E+10 | 0.00 | 0.00 |
September | 0.245031E+10 | 0.233622E+10 | 0.295420E+10 | 753526.11 | 0.295345E+10 | 0.00 | 0.00 |
October | 0.104288E+10 | 0.362260E+10 | 0.211960E+10 | 0.00 | 0.211960E+10 | 0.00 | 0.00 |
November | 0.187460E+09 | 0.550116E+10 | 0.135817E+10 | 0.00 | 0.135817E+10 | 0.00 | 0.00 |
December | 10053842.61 | 0.965004E+10 | 0.117647E+10 | 0.00 | 0.117647E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.268411E+11 | 0.540116E+11 | 0.360341E+11 | 0.139030E+10 | 0.346438E+11 | 0.00 | 0.00 |
Minimum of Months | 10053842.61 | 0.134144E+10 | 0.117647E+10 | 0.00 | 0.117647E+10 | 0.00 | 0.00 |
Maximum of Months | 0.589900E+10 | 0.100891E+11 | 0.523217E+10 | 0.581104E+09 | 0.471492E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.884944E+09 | 0.608267E+10 | 0.203256E+10 | 0.850253E+09 | 0.118231E+10 | 0.00 | 0.00 |
February | 0.184735E+10 | 0.428646E+10 | 0.288258E+10 | 0.123077E+10 | 0.165181E+10 | 0.00 | 0.00 |
March | 0.344465E+10 | 0.373727E+10 | 0.434310E+10 | 0.217741E+10 | 0.216569E+10 | 0.00 | 0.00 |
April | 0.571523E+10 | 0.222040E+10 | 0.582390E+10 | 0.313864E+10 | 0.268526E+10 | 0.00 | 0.00 |
May | 0.714816E+10 | 0.134635E+10 | 0.651487E+10 | 0.286129E+10 | 0.365358E+10 | 0.00 | 0.00 |
June | 0.843914E+10 | 0.923311E+09 | 0.713683E+10 | 0.341089E+10 | 0.372595E+10 | 0.00 | 0.00 |
July | 0.874148E+10 | 0.904026E+09 | 0.722410E+10 | 0.338861E+10 | 0.383549E+10 | 0.00 | 0.00 |
August | 0.652701E+10 | 0.102027E+10 | 0.557035E+10 | 0.243219E+10 | 0.313816E+10 | 0.00 | 0.00 |
September | 0.458663E+10 | 0.151516E+10 | 0.431805E+10 | 0.193145E+10 | 0.238660E+10 | 0.00 | 0.00 |
October | 0.224800E+10 | 0.231982E+10 | 0.270353E+10 | 0.102533E+10 | 0.167819E+10 | 0.00 | 0.00 |
November | 0.901311E+09 | 0.341090E+10 | 0.166719E+10 | 0.558562E+09 | 0.110862E+10 | 0.00 | 0.00 |
December | 0.553523E+09 | 0.588316E+10 | 0.157267E+10 | 0.582760E+09 | 0.989909E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.510374E+11 | 0.336498E+11 | 0.517897E+11 | 0.235881E+11 | 0.282016E+11 | 0.00 | 0.00 |
Minimum of Months | 0.553523E+09 | 0.904026E+09 | 0.157267E+10 | 0.558562E+09 | 0.989909E+09 | 0.00 | 0.00 |
Maximum of Months | 0.874148E+10 | 0.608267E+10 | 0.722410E+10 | 0.341089E+10 | 0.383549E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.830454E+10 | 0.819245E+10 | 0.953720E+10 | 0.662744E+10 | 0.290976E+10 | 0.00 | 0.00 |
February | 0.105481E+11 | 0.618296E+10 | 0.109210E+11 | 0.737172E+10 | 0.354926E+10 | 0.00 | 0.00 |
March | 0.104988E+11 | 0.568558E+10 | 0.106765E+11 | 0.675990E+10 | 0.391657E+10 | 0.00 | 0.00 |
April | 0.999220E+10 | 0.362869E+10 | 0.937675E+10 | 0.510033E+10 | 0.427643E+10 | 0.00 | 0.00 |
May | 0.932585E+10 | 0.221155E+10 | 0.814957E+10 | 0.280200E+10 | 0.534757E+10 | 0.00 | 0.00 |
June | 0.860388E+10 | 0.146897E+10 | 0.707692E+10 | 0.190191E+10 | 0.517500E+10 | 0.00 | 0.00 |
July | 0.100737E+11 | 0.144068E+10 | 0.799678E+10 | 0.255079E+10 | 0.544599E+10 | 0.00 | 0.00 |
August | 0.104659E+11 | 0.165611E+10 | 0.853514E+10 | 0.358316E+10 | 0.495198E+10 | 0.00 | 0.00 |
September | 0.101237E+11 | 0.246659E+10 | 0.883720E+10 | 0.471247E+10 | 0.412473E+10 | 0.00 | 0.00 |
October | 0.803664E+10 | 0.360956E+10 | 0.778493E+10 | 0.457804E+10 | 0.320690E+10 | 0.00 | 0.00 |
November | 0.620314E+10 | 0.493988E+10 | 0.669861E+10 | 0.419893E+10 | 0.249968E+10 | 0.00 | 0.00 |
December | 0.596531E+10 | 0.788016E+10 | 0.736287E+10 | 0.482113E+10 | 0.254174E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.108142E+12 | 0.493632E+11 | 0.102953E+12 | 0.550078E+11 | 0.479456E+11 | 0.00 | 0.00 |
Minimum of Months | 0.596531E+10 | 0.144068E+10 | 0.669861E+10 | 0.190191E+10 | 0.249968E+10 | 0.00 | 0.00 |
Maximum of Months | 0.105481E+11 | 0.819245E+10 | 0.109210E+11 | 0.737172E+10 | 0.544599E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.954074E+09 | 0.626904E+10 | 0.205387E+10 | 0.861588E+09 | 0.119228E+10 | 0.00 | 0.00 |
February | 0.209241E+10 | 0.452576E+10 | 0.302028E+10 | 0.138038E+10 | 0.163990E+10 | 0.00 | 0.00 |
March | 0.359798E+10 | 0.397409E+10 | 0.439504E+10 | 0.224756E+10 | 0.214749E+10 | 0.00 | 0.00 |
April | 0.529660E+10 | 0.242465E+10 | 0.543138E+10 | 0.274829E+10 | 0.268309E+10 | 0.00 | 0.00 |
May | 0.773774E+10 | 0.150235E+10 | 0.689567E+10 | 0.328560E+10 | 0.361007E+10 | 0.00 | 0.00 |
June | 0.761920E+10 | 0.101296E+10 | 0.644159E+10 | 0.278276E+10 | 0.365884E+10 | 0.00 | 0.00 |
July | 0.861769E+10 | 0.101744E+10 | 0.710671E+10 | 0.330148E+10 | 0.380522E+10 | 0.00 | 0.00 |
August | 0.692458E+10 | 0.113833E+10 | 0.584803E+10 | 0.265512E+10 | 0.319291E+10 | 0.00 | 0.00 |
September | 0.475715E+10 | 0.163202E+10 | 0.442259E+10 | 0.198510E+10 | 0.243749E+10 | 0.00 | 0.00 |
October | 0.251246E+10 | 0.247501E+10 | 0.288942E+10 | 0.116009E+10 | 0.172933E+10 | 0.00 | 0.00 |
November | 0.955190E+09 | 0.357709E+10 | 0.169984E+10 | 0.574250E+09 | 0.112559E+10 | 0.00 | 0.00 |
December | 0.548394E+09 | 0.607279E+10 | 0.156647E+10 | 0.549713E+09 | 0.101675E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.516135E+11 | 0.356215E+11 | 0.517709E+11 | 0.235319E+11 | 0.282390E+11 | 0.00 | 0.00 |
Minimum of Months | 0.548394E+09 | 0.101296E+10 | 0.156647E+10 | 0.549713E+09 | 0.101675E+10 | 0.00 | 0.00 |
Maximum of Months | 0.861769E+10 | 0.626904E+10 | 0.710671E+10 | 0.330148E+10 | 0.380522E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: GROUNDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: DATACENTER_BOT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: DATACENTER_MID_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: DATACENTER_TOP_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: DATACENTER_BASEMENT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | -16.9 | -17.4 | -20.0 | 3.73 | -31.9 | 33.25 | 98.18 | 0.00 |
February | -11.6 | -12.7 | -16.7 | 4.33 | -26.7 | 48.91 | 138.70 | 0.00 |
March | -6.2 | -7.6 | -10.8 | 3.55 | -19.4 | 56.69 | 163.76 | 0.01 |
April | 3.97 | 0.41 | -4.8 | 4.72 | -9.1 | 70.41 | 207.70 | 0.01 |
May | 13.43 | 8.45 | 3.53 | 3.60 | 2.20 | 102.27 | 202.62 | 0.00 |
June | 18.03 | 14.19 | 11.55 | 3.74 | 7.84 | 104.36 | 210.60 | 0.06 |
July | 19.67 | 16.51 | 14.78 | 3.14 | 8.97 | 101.67 | 223.82 | 0.04 |
August | 17.94 | 15.20 | 13.59 | 3.45 | 8.99 | 87.39 | 175.79 | 0.04 |
September | 12.29 | 9.87 | 7.80 | 3.78 | 3.34 | 70.27 | 143.96 | 0.00 |
October | 5.42 | 3.47 | 1.07 | 3.53 | -4.7 | 51.74 | 90.11 | 0.00 |
November | -2.0 | -3.6 | -6.9 | 4.42 | -13.7 | 34.68 | 65.95 | 0.00 |
December | -14.6 | -15.1 | -18.1 | 3.91 | -28.3 | 29.58 | 68.99 | 0.00 |
Annual Sum or Average | 3.36 | 1.04 | -2.0 | 3.82 | -8.4 | 66.03 | 149.18 | 0.01 |
Minimum of Months | -16.9 | -17.4 | -20.0 | 3.14 | -31.9 | 29.58 | 65.95 | 0.00 |
Maximum of Months | 19.67 | 16.51 | 14.78 | 4.72 | 8.99 | 104.36 | 223.82 | 0.06 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 1.10 | 29-JAN-14:00 | -1.0 | -4.4 | 2.60 | -11.4 | 145.00 | 110.00 |
February | 8.90 | 20-FEB-15:00 | 2.87 | -6.7 | 8.80 | -9.0 | 49.00 | 646.00 |
March | 11.10 | 26-MAR-15:00 | 5.48 | -1.1 | 5.20 | -5.7 | 53.00 | 842.00 |
April | 26.70 | 23-APR-15:00 | 16.95 | 11.10 | 11.30 | 12.03 | 75.50 | 811.00 |
May | 29.40 | 25-MAY-17:00 | 19.26 | 13.90 | 1.50 | 16.49 | 47.50 | 582.00 |
June | 35.00 | 29-JUN-15:00 | 24.72 | 21.10 | 6.70 | 24.66 | 132.00 | 705.00 |
July | 31.10 | 15-JUL-14:20 | 25.35 | 23.33 | 8.07 | 19.93 | 299.67 | 518.33 |
August | 30.60 | 08-AUG-14:00 | 23.36 | 20.60 | 6.70 | 17.93 | 163.50 | 672.50 |
September | 26.10 | 01-SEP-14:00 | 17.82 | 13.30 | 3.60 | 14.28 | 112.00 | 751.50 |
October | 22.20 | 19-OCT-14:00 | 13.62 | 7.20 | 6.70 | 8.15 | 35.50 | 701.50 |
November | 18.30 | 01-NOV-14:00 | 13.44 | 10.00 | 3.10 | 11.84 | 105.00 | 30.50 |
December | 1.10 | 28-DEC-02:00 | 0.43 | -0.6 | 4.60 | -5.5 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 1.10 | -1.0 | -6.7 | 1.50 | -11.4 | 0.00 | 0.00 | |
Maximum of Months | 35.00 | 25.35 | 23.33 | 11.30 | 24.66 | 299.67 | 842.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -35.6 | 06-JAN-08:00 | -35.7 | -37.8 | 0.00 | -57.8 | 27.00 | 381.00 |
February | -33.3 | 14-FEB-06:00 | -33.4 | -36.7 | 0.00 | -55.6 | 0.00 | 0.00 |
March | -28.9 | 05-MAR-06:00 | -29.1 | -32.2 | 1.50 | -50.6 | 27.00 | 41.50 |
April | -13.9 | 05-APR-05:00 | -14.4 | -16.1 | 0.00 | -32.5 | 14.50 | 199.00 |
May | -3.9 | 01-MAY-05:00 | -6.2 | -12.2 | 0.00 | -22.4 | 35.00 | 415.00 |
June | 1.10 | 04-JUN-04:00 | 0.62 | 0.00 | 0.00 | -14.9 | 37.00 | 169.50 |
July | 6.10 | 02-JUL-04:00 | 6.10 | 6.10 | 0.00 | -8.8 | 33.50 | 204.50 |
August | 4.40 | 19-AUG-03:00 | 4.40 | 4.40 | 0.00 | -10.7 | 0.00 | 0.00 |
September | 1.10 | 06-SEP-03:00 | 1.10 | 1.10 | 0.00 | -14.7 | 0.00 | 0.00 |
October | -10.0 | 30-OCT-03:00 | -10.7 | -12.8 | 1.50 | -28.2 | 0.00 | 0.00 |
November | -20.6 | 29-NOV-05:00 | -20.8 | -22.2 | 2.10 | -37.8 | 0.00 | 0.00 |
December | -31.1 | 24-DEC-06:19 | -31.3 | -35.1 | 3.33 | -53.1 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -35.6 | -35.7 | -37.8 | 0.00 | -57.8 | 0.00 | 0.00 | |
Maximum of Months | 6.10 | 6.10 | 6.10 | 3.33 | -8.8 | 37.00 | 415.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -0.5 | 16-JAN-12:00 | 0.00 | -1.1 | 5.70 | -6.6 | 172.50 | 3.00 |
February | 3.34 | 21-FEB-12:00 | 6.70 | -1.1 | 7.70 | -6.0 | 270.00 | 303.00 |
March | 5.48 | 26-MAR-15:00 | 11.10 | -1.1 | 5.20 | -5.7 | 53.00 | 842.00 |
April | 16.95 | 23-APR-15:00 | 26.70 | 11.10 | 11.30 | 12.03 | 75.50 | 811.00 |
May | 19.91 | 26-MAY-11:00 | 25.60 | 17.20 | 6.20 | 22.64 | 300.50 | 6.00 |
June | 24.72 | 29-JUN-15:00 | 35.00 | 21.10 | 6.70 | 24.66 | 132.00 | 705.00 |
July | 25.76 | 15-JUL-13:00 | 31.10 | 23.90 | 7.70 | 18.99 | 333.00 | 421.00 |
August | 23.36 | 08-AUG-14:00 | 30.60 | 20.60 | 6.70 | 17.93 | 163.50 | 672.50 |
September | 18.67 | 01-SEP-00:00 | 19.00 | 17.50 | 2.80 | 16.30 | 0.00 | 0.00 |
October | 13.72 | 19-OCT-13:00 | 21.70 | 7.80 | 5.70 | 7.75 | 54.50 | 739.00 |
November | 14.29 | 21-NOV-12:00 | 15.00 | 13.90 | 5.20 | 11.46 | 134.50 | 25.50 |
December | 0.43 | 28-DEC-02:00 | 1.10 | -0.6 | 4.60 | -5.5 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -0.5 | 0.00 | -1.1 | 2.80 | -6.6 | 0.00 | 0.00 | |
Maximum of Months | 25.76 | 35.00 | 23.90 | 11.30 | 24.66 | 333.00 | 842.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -1.1 | 16-JAN-11:00 | -0.6 | -0.8 | 5.70 | -7.3 | 164.50 | 5.00 |
February | -0.6 | 21-FEB-08:00 | 4.40 | 2.25 | 8.80 | -6.6 | 123.00 | 89.50 |
March | 0.00 | 29-MAR-20:00 | 1.70 | 0.95 | 1.50 | -4.8 | 0.00 | 0.00 |
April | 11.10 | 23-APR-13:00 | 24.40 | 16.08 | 10.80 | 9.72 | 98.50 | 903.50 |
May | 17.20 | 26-MAY-11:00 | 25.60 | 19.91 | 6.20 | 22.64 | 300.50 | 6.00 |
June | 22.80 | 29-JUN-23:19 | 26.30 | 23.71 | 5.20 | 14.28 | 0.00 | 0.00 |
July | 23.90 | 15-JUL-13:00 | 31.10 | 25.76 | 7.70 | 18.99 | 333.00 | 421.00 |
August | 20.60 | 08-AUG-14:00 | 30.60 | 23.36 | 6.70 | 17.93 | 163.50 | 672.50 |
September | 17.92 | 01-SEP-00:10 | 19.75 | 18.15 | 3.22 | 13.23 | 0.00 | 0.00 |
October | 12.20 | 07-OCT-12:20 | 14.47 | 13.17 | 3.43 | 9.20 | 163.17 | 18.50 |
November | 13.90 | 21-NOV-12:00 | 15.00 | 14.29 | 5.20 | 11.46 | 134.50 | 25.50 |
December | -0.0 | 05-DEC-17:00 | 0.00 | -0.0 | 1.50 | -6.4 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -1.1 | -0.6 | -0.8 | 1.50 | -7.3 | 0.00 | 0.00 | |
Maximum of Months | 23.90 | 31.10 | 25.76 | 10.80 | 22.64 | 333.00 | 903.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 1.89 | 11.66 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 0.58 | 19.92 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 0.81 | 26.63 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 2.58 | 37.52 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 5.43 | 45.25 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 8.61 | 47.76 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 11.25 | 48.86 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 12.66 | 38.94 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 12.41 | 29.23 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 10.60 | 17.37 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 7.72 | 10.89 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 4.55 | 9.11 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 6.63 | 28.63 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 0.58 | 9.11 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 12.66 | 48.86 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.465199E+11 | -0.454677E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.105214E+10 | 58.98 | 0.00 | 0.00 |
February | 0.431945E+11 | -0.422601E+11 | 0.00 | 0.00 | 672.00 | 0.00 | -934365029.1 | 58.98 | 0.00 | 0.00 |
March | 0.505520E+11 | -0.495196E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.103241E+10 | 58.98 | 0.00 | 0.00 |
April | 0.445405E+11 | -0.435469E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -993531960.1 | 58.98 | 0.00 | 0.00 |
May | 0.452014E+11 | -0.441758E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.102554E+10 | 58.99 | 0.00 | 0.00 |
June | 0.421691E+11 | -0.411764E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -992713095.7 | 58.98 | 0.00 | 0.00 |
July | 0.381089E+11 | -0.370895E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.101930E+10 | 58.98 | 0.00 | 0.00 |
August | 0.404658E+11 | -0.394422E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.102362E+10 | 58.98 | 0.00 | 0.00 |
September | 0.369506E+11 | -0.359622E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -988321912.9 | 58.97 | 0.00 | 0.00 |
October | 0.395699E+11 | -0.385483E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.102156E+10 | 58.98 | 0.00 | 0.00 |
November | 0.410444E+11 | -0.400533E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -991136404.4 | 58.98 | 0.00 | 0.00 |
December | 0.433371E+11 | -0.423047E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.103235E+10 | 58.98 | 0.00 | 0.00 |
Annual Sum or Average | 0.511654E+12 | -0.499547E+12 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.121070E+11 | 58.98 | 0.00 | 0.00 |
Minimum of Months | 0.369506E+11 | -0.495196E+11 | 0.00 | 0.00 | 672.00 | 0.00 | -0.105214E+10 | 58.97 | 0.00 | 0.00 |
Maximum of Months | 0.505520E+11 | -0.359622E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -934365029.1 | 58.99 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_1_DAYLCTRL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 243.33 | 0.63 | 0.61 | 01-JAN-08:39 | 4399.83 | 29.91 | 173.83 | 230.50 | 4071.20 | 36.60 | 241.33 | 220.17 |
February | 265.33 | 0.63 | 0.61 | 01-FEB-08:39 | 7479.99 | 33.77 | 234.33 | 250.67 | 3109.17 | 29.84 | 218.50 | 234.83 |
March | 254.17 | 0.63 | 0.61 | 02-MAR-10:39 | 10911.75 | 34.47 | 215.00 | 314.83 | 1546.88 | 21.42 | 163.33 | 276.00 |
April | 296.33 | 0.64 | 0.61 | 01-APR-07:30 | 2023.94 | 17.34 | 0.33 | 340.50 | 1218.91 | 20.34 | 141.00 | 301.67 |
May | 437.50 | 0.63 | 0.61 | 01-MAY-05:00 | 1806.75 | 17.84 | 0.00 | 399.17 | 989.47 | 20.81 | 210.33 | 352.33 |
June | 401.83 | 0.63 | 0.61 | 01-JUN-05:10 | 1714.82 | 17.86 | 0.00 | 401.67 | 954.92 | 20.84 | 199.67 | 352.83 |
July | 409.17 | 0.63 | 0.61 | 01-JUL-05:10 | 1855.26 | 18.15 | 0.00 | 407.50 | 1040.86 | 21.15 | 212.33 | 363.00 |
August | 352.83 | 0.63 | 0.61 | 01-AUG-07:40 | 2380.24 | 18.92 | 10.00 | 368.67 | 1206.44 | 21.47 | 199.17 | 325.33 |
September | 344.17 | 0.63 | 0.61 | 01-SEP-06:19 | 4978.49 | 23.32 | 121.67 | 323.00 | 1247.87 | 21.53 | 201.17 | 286.83 |
October | 299.00 | 0.62 | 0.61 | 01-OCT-06:49 | 5343.10 | 31.02 | 262.33 | 290.00 | 1381.03 | 25.48 | 222.17 | 264.67 |
November | 255.50 | 0.63 | 0.61 | 01-NOV-07:00 | 3685.74 | 30.82 | 210.83 | 232.67 | 3191.46 | 35.42 | 247.00 | 212.33 |
December | 226.33 | 0.63 | 0.61 | 01-DEC-08:30 | 3072.76 | 26.98 | 141.00 | 214.83 | 2986.66 | 34.95 | 216.17 | 197.50 |
Annual Sum or Average | 3785.50 | 0.63 | 3818.55 | 23.91 | 1369.33 | 3774.00 | 1736.09 | 24.83 | 2472.17 | 3387.50 | ||
Minimum of Months | 226.33 | 0.62 | 0.61 | 1714.82 | 17.34 | 0.00 | 214.83 | 954.92 | 20.34 | 141.00 | 197.50 | |
Maximum of Months | 437.50 | 0.64 | 0.61 | 10911.75 | 34.47 | 262.33 | 407.50 | 4071.20 | 36.60 | 247.00 | 363.00 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_2_DAYLCTRL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 243.33 | 0.64 | 0.61 | 01-JAN-08:39 | 1464.60 | 19.67 | 78.67 | 208.67 | 907.83 | 20.82 | 71.50 | 170.17 |
February | 265.33 | 0.63 | 0.61 | 01-FEB-08:39 | 1985.07 | 19.48 | 71.83 | 236.67 | 1015.14 | 18.97 | 44.33 | 203.83 |
March | 254.17 | 0.63 | 0.61 | 02-MAR-10:39 | 3143.76 | 18.75 | 60.83 | 304.00 | 2072.22 | 20.16 | 58.17 | 258.33 |
April | 296.33 | 0.64 | 0.61 | 01-APR-06:00 | 3428.64 | 15.74 | 39.17 | 345.83 | 2141.64 | 14.58 | 0.00 | 305.67 |
May | 437.50 | 0.63 | 0.61 | 01-MAY-05:10 | 3327.84 | 15.73 | 43.33 | 407.83 | 1462.11 | 15.24 | 0.00 | 369.83 |
June | 401.83 | 0.63 | 0.61 | 01-JUN-04:49 | 3956.85 | 13.96 | 0.00 | 408.33 | 1859.56 | 15.36 | 0.00 | 366.17 |
July | 409.17 | 0.63 | 0.61 | 01-JUL-04:49 | 3829.63 | 14.31 | 3.67 | 414.33 | 1750.99 | 15.63 | 0.00 | 379.83 |
August | 352.83 | 0.63 | 0.61 | 01-AUG-07:40 | 3250.26 | 16.53 | 43.83 | 371.33 | 1365.46 | 15.92 | 3.67 | 326.17 |
September | 344.17 | 0.63 | 0.61 | 01-SEP-05:00 | 2470.32 | 17.70 | 65.17 | 319.17 | 1344.94 | 17.52 | 38.83 | 277.67 |
October | 299.00 | 0.63 | 0.61 | 01-OCT-06:40 | 1795.70 | 17.85 | 72.33 | 274.00 | 794.80 | 17.49 | 40.33 | 224.17 |
November | 255.50 | 0.64 | 0.61 | 01-NOV-07:00 | 1227.81 | 18.37 | 73.33 | 213.00 | 658.38 | 18.03 | 51.00 | 163.33 |
December | 226.33 | 0.64 | 0.61 | 01-DEC-08:30 | 1024.07 | 17.63 | 52.50 | 192.33 | 750.16 | 20.50 | 69.33 | 149.17 |
Annual Sum or Average | 3785.50 | 0.63 | 2744.80 | 16.82 | 604.67 | 3695.50 | 1393.54 | 17.15 | 377.17 | 3194.33 | ||
Minimum of Months | 226.33 | 0.63 | 0.61 | 1024.07 | 13.96 | 0.00 | 192.33 | 658.38 | 14.58 | 0.00 | 149.17 | |
Maximum of Months | 437.50 | 0.64 | 0.61 | 3956.85 | 19.67 | 78.67 | 414.33 | 2141.64 | 20.82 | 71.50 | 379.83 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_3_DAYLCTRL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 243.33 | 0.65 | 0.61 | 01-JAN-09:30 | 544.32 | 0.00 | 0.00 | 186.83 | 314.67 | 0.00 | 0.00 | 91.33 |
February | 265.33 | 0.64 | 0.61 | 01-FEB-08:50 | 686.36 | 0.00 | 0.00 | 225.17 | 411.66 | 0.00 | 0.00 | 167.67 |
March | 254.17 | 0.64 | 0.61 | 02-MAR-10:39 | 738.94 | 0.00 | 0.00 | 294.83 | 475.02 | 0.00 | 0.00 | 218.33 |
April | 296.33 | 0.64 | 0.61 | 01-APR-07:40 | 844.42 | 0.00 | 0.00 | 347.83 | 536.97 | 0.00 | 0.00 | 289.83 |
May | 437.50 | 0.62 | 0.61 | 01-MAY-05:19 | 1169.85 | 0.00 | 0.00 | 425.50 | 668.82 | 0.00 | 0.00 | 394.83 |
June | 401.83 | 0.62 | 0.61 | 01-JUN-04:49 | 1372.57 | 0.00 | 0.00 | 428.67 | 762.85 | 0.00 | 0.00 | 389.67 |
July | 409.17 | 0.62 | 0.61 | 01-JUL-04:49 | 1314.20 | 0.00 | 0.00 | 430.83 | 781.06 | 0.00 | 0.00 | 404.67 |
August | 352.83 | 0.62 | 0.61 | 01-AUG-07:40 | 1076.84 | 0.00 | 0.00 | 376.50 | 654.14 | 0.00 | 0.00 | 329.83 |
September | 344.17 | 0.63 | 0.61 | 01-SEP-06:19 | 836.79 | 0.00 | 0.00 | 317.17 | 491.20 | 0.00 | 0.00 | 256.33 |
October | 299.00 | 0.63 | 0.61 | 01-OCT-06:00 | 690.58 | 0.00 | 0.00 | 260.00 | 385.34 | 0.00 | 0.00 | 174.67 |
November | 255.50 | 0.65 | 0.61 | 01-NOV-08:09 | 533.14 | 0.00 | 0.00 | 193.50 | 295.79 | 0.00 | 0.00 | 78.67 |
December | 226.33 | 0.65 | 0.61 | 01-DEC-08:00 | 507.70 | 0.00 | 0.00 | 171.83 | 282.64 | 0.00 | 0.00 | 42.83 |
Annual Sum or Average | 3785.50 | 0.63 | 919.10 | 0.00 | 0.00 | 3658.67 | 538.64 | 0.00 | 0.00 | 2838.67 | ||
Minimum of Months | 226.33 | 0.62 | 0.61 | 507.70 | 0.00 | 0.00 | 171.83 | 282.64 | 0.00 | 0.00 | 42.83 | |
Maximum of Months | 437.50 | 0.65 | 0.61 | 1372.57 | 0.00 | 0.00 | 430.83 | 781.06 | 0.00 | 0.00 | 404.67 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_4_DAYLCTRL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 243.33 | 0.64 | 0.61 | 01-JAN-09:30 | 1430.53 | 19.70 | 76.17 | 211.50 | 783.44 | 19.07 | 50.67 | 170.00 |
February | 265.33 | 0.63 | 0.61 | 01-FEB-08:00 | 1754.27 | 17.68 | 47.33 | 239.67 | 1038.22 | 19.22 | 45.50 | 207.83 |
March | 254.17 | 0.63 | 0.61 | 02-MAR-10:39 | 2976.48 | 18.85 | 59.67 | 305.17 | 1861.14 | 18.50 | 37.50 | 255.33 |
April | 296.33 | 0.64 | 0.61 | 01-APR-07:49 | 3772.69 | 17.33 | 63.17 | 341.33 | 1622.25 | 14.63 | 0.00 | 302.17 |
May | 437.50 | 0.63 | 0.61 | 01-MAY-06:10 | 2873.18 | 13.79 | 0.00 | 408.83 | 1734.72 | 15.20 | 0.00 | 371.33 |
June | 401.83 | 0.63 | 0.61 | 01-JUN-05:10 | 3278.50 | 14.11 | 0.00 | 419.33 | 1408.12 | 17.52 | 43.83 | 376.17 |
July | 409.17 | 0.62 | 0.61 | 01-JUL-05:19 | 3537.57 | 14.23 | 0.00 | 420.00 | 1534.49 | 17.43 | 38.67 | 378.83 |
August | 352.83 | 0.63 | 0.61 | 01-AUG-07:40 | 3062.94 | 14.79 | 8.33 | 371.83 | 1775.53 | 16.09 | 5.33 | 326.50 |
September | 344.17 | 0.63 | 0.61 | 01-SEP-06:40 | 2531.74 | 17.73 | 67.17 | 320.33 | 1528.43 | 17.67 | 42.00 | 282.00 |
October | 299.00 | 0.63 | 0.61 | 01-OCT-07:10 | 1932.70 | 18.31 | 75.83 | 275.00 | 834.25 | 17.77 | 41.17 | 227.33 |
November | 255.50 | 0.64 | 0.61 | 01-NOV-08:09 | 1202.23 | 18.26 | 70.67 | 214.83 | 624.52 | 17.76 | 46.00 | 166.50 |
December | 226.33 | 0.64 | 0.61 | 01-DEC-08:00 | 1024.09 | 17.01 | 44.50 | 198.00 | 585.10 | 18.34 | 43.17 | 145.83 |
Annual Sum or Average | 3785.50 | 0.63 | 2583.23 | 16.44 | 512.83 | 3725.83 | 1338.38 | 17.27 | 393.83 | 3209.83 | ||
Minimum of Months | 226.33 | 0.62 | 0.61 | 1024.09 | 13.79 | 0.00 | 198.00 | 585.10 | 14.63 | 0.00 | 145.83 | |
Maximum of Months | 437.50 | 0.64 | 0.61 | 3772.69 | 19.70 | 76.17 | 420.00 | 1861.14 | 19.22 | 50.67 | 378.83 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_1_DAYLCTRL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 243.33 | 0.63 | 0.61 | 01-JAN-08:39 | 4046.08 | 24.76 | 144.00 | 229.83 | 4067.74 | 34.73 | 219.17 | 218.83 |
February | 265.33 | 0.63 | 0.61 | 01-FEB-08:39 | 7424.40 | 32.88 | 233.17 | 249.67 | 4020.58 | 31.57 | 199.83 | 239.67 |
March | 254.17 | 0.63 | 0.61 | 02-MAR-10:39 | 10883.30 | 33.60 | 215.00 | 313.83 | 1610.49 | 16.92 | 0.00 | 277.50 |
April | 296.33 | 0.64 | 0.61 | 01-APR-07:30 | 2004.09 | 11.53 | 0.00 | 339.00 | 1269.97 | 16.40 | 0.00 | 303.00 |
May | 437.50 | 0.63 | 0.61 | 01-MAY-05:00 | 1772.49 | 12.13 | 0.00 | 396.83 | 1022.46 | 16.88 | 0.00 | 353.67 |
June | 401.83 | 0.64 | 0.61 | 01-JUN-05:10 | 1683.20 | 12.40 | 0.00 | 399.33 | 985.66 | 17.15 | 0.00 | 354.83 |
July | 409.17 | 0.63 | 0.61 | 01-JUL-05:10 | 1822.51 | 12.68 | 0.00 | 406.50 | 1075.20 | 17.47 | 0.00 | 365.00 |
August | 352.83 | 0.63 | 0.61 | 01-AUG-07:40 | 2338.17 | 13.36 | 10.00 | 367.33 | 1247.07 | 17.49 | 0.00 | 327.33 |
September | 344.17 | 0.63 | 0.61 | 01-SEP-06:19 | 4930.20 | 19.53 | 113.17 | 321.67 | 1290.50 | 17.20 | 7.00 | 288.00 |
October | 299.00 | 0.62 | 0.61 | 01-OCT-06:49 | 5266.20 | 29.74 | 249.83 | 287.67 | 1417.61 | 22.02 | 104.00 | 265.33 |
November | 255.50 | 0.63 | 0.61 | 01-NOV-07:00 | 3235.33 | 23.92 | 153.00 | 230.33 | 3224.56 | 35.02 | 245.17 | 213.00 |
December | 226.33 | 0.63 | 0.61 | 01-DEC-08:30 | 1964.12 | 13.95 | 44.17 | 213.83 | 3015.09 | 34.09 | 207.83 | 198.17 |
Annual Sum or Average | 3785.50 | 0.63 | 3666.53 | 18.96 | 1162.33 | 3755.83 | 1833.29 | 21.86 | 983.00 | 3404.33 | ||
Minimum of Months | 226.33 | 0.62 | 0.61 | 1683.20 | 11.53 | 0.00 | 213.83 | 985.66 | 16.40 | 0.00 | 198.17 | |
Maximum of Months | 437.50 | 0.64 | 0.61 | 10883.30 | 33.60 | 249.83 | 406.50 | 4067.74 | 35.02 | 245.17 | 365.00 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_2_DAYLCTRL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 243.33 | 0.64 | 0.61 | 01-JAN-08:39 | 1457.42 | 17.74 | 78.17 | 207.83 | 925.52 | 18.99 | 69.67 | 173.00 |
February | 265.33 | 0.63 | 0.61 | 01-FEB-08:39 | 1747.45 | 15.04 | 47.33 | 236.67 | 1041.50 | 16.72 | 44.17 | 206.17 |
March | 254.17 | 0.63 | 0.61 | 02-MAR-10:39 | 3150.40 | 16.38 | 60.83 | 303.67 | 2111.35 | 18.23 | 58.17 | 261.50 |
April | 296.33 | 0.64 | 0.61 | 01-APR-06:00 | 3441.28 | 12.92 | 39.17 | 345.33 | 2187.12 | 11.94 | 0.00 | 308.00 |
May | 437.50 | 0.63 | 0.61 | 01-MAY-05:10 | 3323.35 | 12.82 | 43.33 | 407.00 | 1499.42 | 12.76 | 0.00 | 372.00 |
June | 401.83 | 0.63 | 0.61 | 01-JUN-04:49 | 3943.03 | 10.54 | 0.00 | 407.00 | 1903.29 | 12.93 | 0.00 | 369.17 |
July | 409.17 | 0.63 | 0.61 | 01-JUL-04:49 | 3789.28 | 10.94 | 3.67 | 413.50 | 1794.69 | 13.18 | 0.00 | 381.17 |
August | 352.83 | 0.63 | 0.61 | 01-AUG-07:40 | 3025.90 | 13.72 | 43.83 | 370.33 | 1403.49 | 13.40 | 3.67 | 328.83 |
September | 344.17 | 0.63 | 0.61 | 01-SEP-05:00 | 2470.38 | 15.28 | 65.00 | 318.33 | 1375.99 | 15.33 | 39.17 | 280.00 |
October | 299.00 | 0.63 | 0.61 | 01-OCT-06:40 | 1788.84 | 15.57 | 72.17 | 273.17 | 816.57 | 15.30 | 40.33 | 227.00 |
November | 255.50 | 0.64 | 0.61 | 01-NOV-07:00 | 1220.83 | 16.27 | 73.83 | 212.33 | 673.56 | 15.97 | 51.33 | 165.83 |
December | 226.33 | 0.64 | 0.61 | 01-DEC-08:30 | 1017.15 | 15.35 | 52.17 | 191.67 | 759.95 | 18.44 | 65.33 | 151.50 |
Annual Sum or Average | 3785.50 | 0.63 | 2700.44 | 14.00 | 579.50 | 3686.83 | 1426.09 | 14.85 | 371.83 | 3224.17 | ||
Minimum of Months | 226.33 | 0.63 | 0.61 | 1017.15 | 10.54 | 0.00 | 191.67 | 673.56 | 11.94 | 0.00 | 151.50 | |
Maximum of Months | 437.50 | 0.64 | 0.61 | 3943.03 | 17.74 | 78.17 | 413.50 | 2187.12 | 18.99 | 69.67 | 381.17 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_3_DAYLCTRL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 243.33 | 0.65 | 0.61 | 01-JAN-09:39 | 531.21 | 0.00 | 0.00 | 183.83 | 322.38 | 0.00 | 0.00 | 99.83 |
February | 265.33 | 0.64 | 0.61 | 01-FEB-08:50 | 671.24 | 0.00 | 0.00 | 222.83 | 422.31 | 0.00 | 0.00 | 171.17 |
March | 254.17 | 0.64 | 0.61 | 02-MAR-10:39 | 726.39 | 0.00 | 0.00 | 292.67 | 488.75 | 0.00 | 0.00 | 223.33 |
April | 296.33 | 0.64 | 0.61 | 01-APR-07:40 | 833.24 | 0.00 | 0.00 | 346.83 | 553.98 | 0.00 | 0.00 | 292.67 |
May | 437.50 | 0.62 | 0.61 | 01-MAY-05:19 | 1128.77 | 0.00 | 0.00 | 422.50 | 688.67 | 0.00 | 0.00 | 397.17 |
June | 401.83 | 0.62 | 0.61 | 01-JUN-04:49 | 1351.38 | 0.00 | 0.00 | 427.00 | 822.28 | 0.00 | 0.00 | 398.67 |
July | 409.17 | 0.62 | 0.61 | 01-JUL-04:49 | 1296.25 | 0.00 | 0.00 | 429.00 | 792.42 | 0.00 | 0.00 | 404.67 |
August | 352.83 | 0.62 | 0.61 | 01-AUG-07:40 | 1074.20 | 0.00 | 0.00 | 377.17 | 673.11 | 0.00 | 0.00 | 333.50 |
September | 344.17 | 0.63 | 0.61 | 01-SEP-06:19 | 820.70 | 0.00 | 0.00 | 315.83 | 505.31 | 0.00 | 0.00 | 260.67 |
October | 299.00 | 0.64 | 0.61 | 01-OCT-06:00 | 675.49 | 0.00 | 0.00 | 256.50 | 395.89 | 0.00 | 0.00 | 182.17 |
November | 255.50 | 0.65 | 0.61 | 01-NOV-08:09 | 520.48 | 0.00 | 0.00 | 191.17 | 303.37 | 0.00 | 0.00 | 89.50 |
December | 226.33 | 0.65 | 0.61 | 01-DEC-08:00 | 495.23 | 0.00 | 0.00 | 167.67 | 289.59 | 0.00 | 0.00 | 51.17 |
Annual Sum or Average | 3785.50 | 0.63 | 902.04 | 0.00 | 0.00 | 3633.00 | 556.77 | 0.00 | 0.00 | 2904.50 | ||
Minimum of Months | 226.33 | 0.62 | 0.61 | 495.23 | 0.00 | 0.00 | 167.67 | 289.59 | 0.00 | 0.00 | 51.17 | |
Maximum of Months | 437.50 | 0.65 | 0.61 | 1351.38 | 0.00 | 0.00 | 429.00 | 822.28 | 0.00 | 0.00 | 404.67 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_4_DAYLCTRL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 243.33 | 0.64 | 0.61 | 01-JAN-09:39 | 1424.49 | 17.78 | 75.50 | 211.00 | 801.71 | 16.95 | 49.33 | 173.00 |
February | 265.33 | 0.63 | 0.61 | 01-FEB-08:00 | 1750.32 | 15.13 | 47.17 | 239.33 | 1065.13 | 16.97 | 45.83 | 209.67 |
March | 254.17 | 0.63 | 0.61 | 02-MAR-10:39 | 2979.40 | 16.51 | 59.67 | 304.33 | 1898.99 | 16.28 | 37.50 | 259.00 |
April | 296.33 | 0.64 | 0.61 | 01-APR-07:49 | 3782.83 | 14.89 | 63.17 | 340.83 | 1665.15 | 12.03 | 0.00 | 305.33 |
May | 437.50 | 0.63 | 0.61 | 01-MAY-06:10 | 2867.63 | 10.34 | 0.00 | 408.67 | 1774.27 | 12.68 | 0.00 | 374.50 |
June | 401.83 | 0.63 | 0.61 | 01-JUN-05:10 | 3263.26 | 10.75 | 0.00 | 418.50 | 1446.74 | 15.47 | 43.83 | 379.00 |
July | 409.17 | 0.62 | 0.61 | 01-JUL-05:19 | 3523.39 | 10.83 | 0.00 | 419.17 | 1576.92 | 15.28 | 38.83 | 381.83 |
August | 352.83 | 0.63 | 0.61 | 01-AUG-07:40 | 3057.92 | 11.48 | 8.33 | 371.17 | 1816.75 | 13.55 | 5.33 | 329.33 |
September | 344.17 | 0.63 | 0.61 | 01-SEP-06:40 | 2532.31 | 15.23 | 66.83 | 319.83 | 1562.01 | 15.45 | 41.83 | 284.83 |
October | 299.00 | 0.63 | 0.61 | 01-OCT-07:10 | 1924.16 | 15.81 | 72.17 | 274.50 | 856.89 | 15.56 | 41.17 | 231.17 |
November | 255.50 | 0.64 | 0.61 | 01-NOV-08:09 | 1095.15 | 14.05 | 49.33 | 214.17 | 639.54 | 15.64 | 45.00 | 170.00 |
December | 226.33 | 0.64 | 0.61 | 01-DEC-08:00 | 1016.14 | 14.64 | 44.17 | 196.00 | 598.93 | 16.20 | 41.00 | 149.50 |
Annual Sum or Average | 3785.50 | 0.63 | 2570.97 | 13.51 | 486.33 | 3717.50 | 1371.12 | 14.99 | 389.67 | 3247.17 | ||
Minimum of Months | 226.33 | 0.62 | 0.61 | 1016.14 | 10.34 | 0.00 | 196.00 | 598.93 | 12.03 | 0.00 | 149.50 | |
Maximum of Months | 437.50 | 0.64 | 0.61 | 3782.83 | 17.78 | 75.50 | 419.17 | 1898.99 | 16.97 | 49.33 | 381.83 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_1_DAYLCTRL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 243.33 | 0.63 | 0.61 | 01-JAN-08:39 | 4044.60 | 24.73 | 144.00 | 229.83 | 4068.79 | 34.73 | 219.17 | 218.83 |
February | 265.33 | 0.63 | 0.61 | 01-FEB-08:39 | 7422.96 | 32.86 | 233.17 | 249.67 | 4022.29 | 31.56 | 199.83 | 239.67 |
March | 254.17 | 0.63 | 0.61 | 02-MAR-10:39 | 10883.08 | 33.59 | 215.00 | 314.00 | 1612.10 | 16.90 | 0.00 | 277.50 |
April | 296.33 | 0.64 | 0.61 | 01-APR-07:30 | 2004.78 | 11.49 | 0.00 | 339.00 | 1271.18 | 16.38 | 0.00 | 303.00 |
May | 437.50 | 0.63 | 0.61 | 01-MAY-05:00 | 1773.49 | 12.09 | 0.00 | 396.83 | 1023.70 | 16.87 | 0.00 | 353.67 |
June | 401.83 | 0.64 | 0.61 | 01-JUN-05:10 | 1684.03 | 12.36 | 0.00 | 399.33 | 986.78 | 17.14 | 0.00 | 354.83 |
July | 409.17 | 0.63 | 0.61 | 01-JUL-05:10 | 1823.37 | 12.64 | 0.00 | 406.50 | 1076.40 | 17.45 | 0.00 | 365.50 |
August | 352.83 | 0.63 | 0.61 | 01-AUG-07:40 | 2339.22 | 13.32 | 10.00 | 367.33 | 1248.56 | 17.48 | 0.00 | 327.67 |
September | 344.17 | 0.63 | 0.61 | 01-SEP-06:19 | 4930.90 | 19.50 | 113.17 | 321.67 | 1292.07 | 17.18 | 7.00 | 288.00 |
October | 299.00 | 0.62 | 0.61 | 01-OCT-06:49 | 5265.95 | 29.73 | 249.83 | 287.67 | 1418.60 | 21.90 | 102.50 | 265.00 |
November | 255.50 | 0.63 | 0.61 | 01-NOV-07:00 | 3234.27 | 23.90 | 153.00 | 230.33 | 3207.45 | 33.90 | 234.50 | 211.33 |
December | 226.33 | 0.63 | 0.61 | 01-DEC-08:30 | 1963.01 | 13.91 | 44.17 | 213.83 | 3015.99 | 34.08 | 207.83 | 198.17 |
Annual Sum or Average | 3785.50 | 0.63 | 3666.67 | 18.93 | 1162.33 | 3756.00 | 1833.33 | 21.76 | 970.83 | 3403.17 | ||
Minimum of Months | 226.33 | 0.62 | 0.61 | 1684.03 | 11.49 | 0.00 | 213.83 | 986.78 | 16.38 | 0.00 | 198.17 | |
Maximum of Months | 437.50 | 0.64 | 0.61 | 10883.08 | 33.59 | 249.83 | 406.50 | 4068.79 | 34.73 | 234.50 | 365.50 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_2_DAYLCTRL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 243.33 | 0.64 | 0.61 | 01-JAN-08:39 | 1457.19 | 17.73 | 78.17 | 208.00 | 926.11 | 18.98 | 69.67 | 173.00 |
February | 265.33 | 0.63 | 0.61 | 01-FEB-08:39 | 1747.05 | 15.03 | 47.33 | 236.50 | 1042.26 | 16.71 | 44.17 | 206.17 |
March | 254.17 | 0.63 | 0.61 | 02-MAR-10:39 | 3149.65 | 16.37 | 60.83 | 303.67 | 2112.12 | 18.22 | 58.17 | 261.50 |
April | 296.33 | 0.64 | 0.61 | 01-APR-06:00 | 3440.70 | 12.90 | 39.17 | 345.17 | 2187.93 | 11.93 | 0.00 | 308.00 |
May | 437.50 | 0.63 | 0.61 | 01-MAY-05:10 | 3323.50 | 12.80 | 43.33 | 407.00 | 1500.56 | 12.75 | 0.00 | 372.50 |
June | 401.83 | 0.63 | 0.61 | 01-JUN-04:49 | 3942.74 | 10.52 | 0.00 | 407.00 | 1904.46 | 12.93 | 0.00 | 369.33 |
July | 409.17 | 0.63 | 0.61 | 01-JUL-04:49 | 3788.91 | 10.93 | 3.67 | 413.50 | 1795.85 | 13.17 | 0.00 | 381.17 |
August | 352.83 | 0.63 | 0.61 | 01-AUG-07:40 | 3025.64 | 13.70 | 43.83 | 370.33 | 1404.61 | 13.39 | 3.67 | 329.17 |
September | 344.17 | 0.63 | 0.61 | 01-SEP-05:00 | 2470.10 | 15.27 | 65.00 | 318.33 | 1376.92 | 15.32 | 39.17 | 280.00 |
October | 299.00 | 0.63 | 0.61 | 01-OCT-06:40 | 1788.79 | 15.56 | 72.17 | 273.17 | 817.37 | 15.29 | 40.33 | 227.33 |
November | 255.50 | 0.64 | 0.61 | 01-NOV-07:00 | 1220.75 | 16.26 | 73.83 | 212.33 | 674.17 | 15.96 | 51.33 | 166.00 |
December | 226.33 | 0.64 | 0.61 | 01-DEC-08:30 | 1017.05 | 15.34 | 52.17 | 191.50 | 760.51 | 18.44 | 65.33 | 151.67 |
Annual Sum or Average | 3785.50 | 0.63 | 2700.18 | 13.99 | 579.50 | 3686.50 | 1427.00 | 14.85 | 371.83 | 3225.83 | ||
Minimum of Months | 226.33 | 0.63 | 0.61 | 1017.05 | 10.52 | 0.00 | 191.50 | 674.17 | 11.93 | 0.00 | 151.67 | |
Maximum of Months | 437.50 | 0.64 | 0.61 | 3942.74 | 17.73 | 78.17 | 413.50 | 2187.93 | 18.98 | 69.67 | 381.17 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_3_DAYLCTRL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 243.33 | 0.65 | 0.61 | 01-JAN-09:39 | 531.20 | 0.00 | 0.00 | 183.67 | 322.72 | 0.00 | 0.00 | 99.83 |
February | 265.33 | 0.64 | 0.61 | 01-FEB-08:50 | 671.15 | 0.00 | 0.00 | 222.83 | 422.71 | 0.00 | 0.00 | 171.17 |
March | 254.17 | 0.64 | 0.61 | 02-MAR-10:39 | 726.15 | 0.00 | 0.00 | 293.00 | 489.09 | 0.00 | 0.00 | 223.50 |
April | 296.33 | 0.64 | 0.61 | 01-APR-07:40 | 833.02 | 0.00 | 0.00 | 346.83 | 554.38 | 0.00 | 0.00 | 293.00 |
May | 437.50 | 0.62 | 0.61 | 01-MAY-05:19 | 1128.90 | 0.00 | 0.00 | 422.50 | 689.35 | 0.00 | 0.00 | 397.33 |
June | 401.83 | 0.62 | 0.61 | 01-JUN-04:49 | 1351.34 | 0.00 | 0.00 | 427.00 | 822.99 | 0.00 | 0.00 | 398.83 |
July | 409.17 | 0.62 | 0.61 | 01-JUL-04:49 | 1296.15 | 0.00 | 0.00 | 428.83 | 793.10 | 0.00 | 0.00 | 404.67 |
August | 352.83 | 0.62 | 0.61 | 01-AUG-07:40 | 1074.16 | 0.00 | 0.00 | 377.17 | 673.73 | 0.00 | 0.00 | 333.67 |
September | 344.17 | 0.63 | 0.61 | 01-SEP-06:19 | 820.75 | 0.00 | 0.00 | 315.83 | 505.82 | 0.00 | 0.00 | 261.00 |
October | 299.00 | 0.64 | 0.61 | 01-OCT-06:00 | 675.65 | 0.00 | 0.00 | 256.50 | 396.36 | 0.00 | 0.00 | 182.50 |
November | 255.50 | 0.65 | 0.61 | 01-NOV-08:09 | 520.58 | 0.00 | 0.00 | 191.00 | 303.73 | 0.00 | 0.00 | 90.17 |
December | 226.33 | 0.65 | 0.61 | 01-DEC-08:00 | 495.30 | 0.00 | 0.00 | 167.67 | 289.93 | 0.00 | 0.00 | 51.33 |
Annual Sum or Average | 3785.50 | 0.63 | 902.02 | 0.00 | 0.00 | 3632.83 | 557.29 | 0.00 | 0.00 | 2907.00 | ||
Minimum of Months | 226.33 | 0.62 | 0.61 | 495.30 | 0.00 | 0.00 | 167.67 | 289.93 | 0.00 | 0.00 | 51.33 | |
Maximum of Months | 437.50 | 0.65 | 0.61 | 1351.34 | 0.00 | 0.00 | 428.83 | 822.99 | 0.00 | 0.00 | 404.67 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_4_DAYLCTRL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 243.33 | 0.64 | 0.61 | 01-JAN-09:39 | 1424.25 | 17.77 | 75.33 | 211.00 | 802.31 | 16.95 | 49.33 | 173.00 |
February | 265.33 | 0.63 | 0.61 | 01-FEB-08:00 | 1749.92 | 15.12 | 47.17 | 239.33 | 1065.87 | 16.97 | 45.83 | 209.83 |
March | 254.17 | 0.63 | 0.61 | 02-MAR-10:39 | 2978.72 | 16.50 | 59.67 | 304.17 | 1899.76 | 16.27 | 37.50 | 259.33 |
April | 296.33 | 0.64 | 0.61 | 01-APR-07:49 | 3782.32 | 14.88 | 63.17 | 340.67 | 1665.97 | 12.02 | 0.00 | 305.33 |
May | 437.50 | 0.63 | 0.61 | 01-MAY-06:10 | 2867.67 | 10.32 | 0.00 | 408.67 | 1775.38 | 12.67 | 0.00 | 374.67 |
June | 401.83 | 0.63 | 0.61 | 01-JUN-05:10 | 3263.12 | 10.74 | 0.00 | 418.50 | 1447.88 | 15.46 | 43.83 | 379.00 |
July | 409.17 | 0.62 | 0.61 | 01-JUL-05:19 | 3523.18 | 10.81 | 0.00 | 419.17 | 1578.09 | 15.27 | 38.83 | 382.00 |
August | 352.83 | 0.63 | 0.61 | 01-AUG-07:40 | 3057.68 | 11.46 | 8.33 | 371.00 | 1817.95 | 13.54 | 5.33 | 329.50 |
September | 344.17 | 0.63 | 0.61 | 01-SEP-06:40 | 2532.12 | 15.22 | 66.83 | 319.67 | 1562.99 | 15.44 | 41.83 | 285.00 |
October | 299.00 | 0.63 | 0.61 | 01-OCT-07:10 | 1924.05 | 15.80 | 72.17 | 274.50 | 857.72 | 15.56 | 41.17 | 231.33 |
November | 255.50 | 0.64 | 0.61 | 01-NOV-08:09 | 1095.04 | 14.04 | 49.33 | 214.17 | 640.15 | 15.63 | 45.00 | 170.00 |
December | 226.33 | 0.64 | 0.61 | 01-DEC-08:00 | 1016.02 | 14.62 | 44.17 | 196.00 | 599.50 | 16.20 | 41.00 | 149.67 |
Annual Sum or Average | 3785.50 | 0.63 | 2570.75 | 13.50 | 486.17 | 3716.83 | 1372.05 | 14.99 | 389.67 | 3248.67 | ||
Minimum of Months | 226.33 | 0.62 | 0.61 | 1016.02 | 10.32 | 0.00 | 196.00 | 599.50 | 12.02 | 0.00 | 149.67 | |
Maximum of Months | 437.50 | 0.64 | 0.61 | 3782.32 | 17.77 | 75.33 | 419.17 | 1899.76 | 16.97 | 49.33 | 382.00 |
Report: CoilReportMonthly
For: VAV_BOT WITH REHEAT HEATING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.350571E+11 | 128320.84 | 06-JAN-09:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.122974E+11 | 126316.31 | 14-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.389669E+10 | 105462.33 | 15-MAR-06:53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.157644E+10 | 72683.91 | 05-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.132595E+09 | 26286.12 | 02-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 1059873.33 | 1473.28 | 02-JUN-20:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.88 | 0.00 | 17-JUL-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 1253577.46 | 1851.34 | 19-AUG-06:35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.119634E+09 | 20744.83 | 23-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.929787E+09 | 61078.20 | 30-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.197120E+10 | 64274.24 | 24-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.179929E+11 | 122184.89 | 20-DEC-08:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.739761E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.350571E+11 | 128320.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_BOTTOM VAV BOX REHEAT COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 66556569.70 | 33762.48 | 02-JAN-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 66556569.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 66556569.70 | 33762.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.501575E+10 | 14842.48 | 20-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.174818E+10 | 14946.54 | 11-FEB-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.417343E+09 | 14959.74 | 13-MAR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 1205386.86 | 774.55 | 05-APR-05:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 89362.32 | 77.37 | 30-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.215850E+09 | 14851.46 | 28-NOV-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.216231E+10 | 14952.17 | 09-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.956072E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.501575E+10 | 14959.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.453706E+10 | 16734.26 | 20-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.202084E+10 | 16749.91 | 28-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.960920E+09 | 16804.14 | 11-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 74982660.93 | 7760.18 | 04-APR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 80946067.61 | 3159.82 | 18-OCT-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.811137E+09 | 16744.89 | 28-NOV-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.323669E+10 | 16827.41 | 29-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.117226E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.453706E+10 | 16827.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.464917E+10 | 23632.47 | 20-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.198545E+10 | 23651.92 | 28-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.951005E+09 | 23751.71 | 10-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.111899E+09 | 23426.43 | 10-APR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.101616E+09 | 17903.15 | 30-OCT-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.831469E+09 | 23702.35 | 13-NOV-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.312368E+10 | 23761.23 | 29-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.117543E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.464917E+10 | 23761.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.335675E+10 | 15300.48 | 10-JAN-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.883139E+09 | 15286.91 | 13-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 64413345.16 | 15280.64 | 15-MAR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 229763.02 | 161.58 | 30-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 66605192.61 | 15283.03 | 25-NOV-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.507734E+09 | 15286.76 | 26-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.487887E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.335675E+10 | 15300.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: VAV_MID WITH REHEAT HEATING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.408260E+12 | 1323908.02 | 09-JAN-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.148227E+12 | 1301520.95 | 14-FEB-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.353885E+11 | 1073768.45 | 15-MAR-06:57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.170797E+11 | 764597.74 | 05-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.295388E+10 | 317422.78 | 02-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.117860E+09 | 93075.89 | 03-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 78072961.45 | 92032.57 | 19-AUG-06:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.242781E+10 | 266957.04 | 06-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.166726E+11 | 642746.43 | 30-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.315380E+11 | 667423.94 | 24-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.234020E+12 | 1244640.94 | 20-DEC-09:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.896763E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.408260E+12 | 1323908.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_MID VAV BOX REHEAT COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.420578E+11 | 646566.32 | 02-JAN-05:24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.737242E+10 | 646254.15 | 27-FEB-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.102576E+10 | 643968.97 | 06-MAR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.344654E+10 | 647040.51 | 27-NOV-06:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.215498E+11 | 646939.48 | 04-DEC-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.754523E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.420578E+11 | 647040.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.138662E+12 | 139592.94 | 06-JAN-08:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.817516E+11 | 133161.90 | 14-FEB-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.455543E+11 | 139495.84 | 30-MAR-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.793123E+10 | 139989.04 | 26-APR-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 45258749.63 | 47176.42 | 01-MAY-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 248686.75 | 580.00 | 23-SEP-06:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.564492E+10 | 137400.26 | 06-OCT-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.385424E+11 | 129118.91 | 27-NOV-05:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.123315E+12 | 129537.04 | 05-DEC-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.441447E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.138662E+12 | 139989.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.103721E+12 | 193671.95 | 03-JAN-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.603202E+11 | 192961.39 | 14-FEB-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.375086E+11 | 192738.81 | 03-MAR-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.896242E+10 | 192537.40 | 03-APR-04:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.133294E+09 | 25017.76 | 09-MAY-05:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 10271516.23 | 3345.91 | 10-JUN-05:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 15701337.24 | 17361.46 | 19-AUG-05:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.113796E+10 | 28954.61 | 21-SEP-05:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.127624E+11 | 191601.89 | 30-OCT-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.403426E+11 | 193765.36 | 27-NOV-05:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.966765E+11 | 193649.55 | 18-DEC-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.361591E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.103721E+12 | 193765.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.979066E+11 | 231631.61 | 17-JAN-05:52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.498495E+11 | 231201.18 | 21-FEB-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.325397E+11 | 230622.22 | 02-MAR-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.823299E+10 | 230530.55 | 04-APR-04:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.154366E+09 | 23921.81 | 01-MAY-05:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.351372E+09 | 23982.72 | 28-SEP-05:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.770359E+10 | 230623.12 | 31-OCT-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.344828E+11 | 231659.08 | 27-NOV-05:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.963126E+11 | 232479.83 | 28-DEC-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.327533E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.979066E+11 | 232479.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.947379E+11 | 201052.36 | 03-JAN-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.535916E+11 | 200961.18 | 14-FEB-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.333508E+11 | 200624.91 | 08-MAR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.828094E+10 | 200164.46 | 04-APR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.213109E+09 | 24984.47 | 01-MAY-05:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 11193469.81 | 3474.66 | 19-AUG-05:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.815691E+09 | 27737.48 | 29-SEP-05:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.976343E+10 | 196438.54 | 30-OCT-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.343054E+11 | 201110.28 | 28-NOV-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.837968E+11 | 201029.52 | 18-DEC-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.318867E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.947379E+11 | 201110.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: VAV_TOP WITH REHEAT HEATING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.488225E+11 | 136201.39 | 06-JAN-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.200454E+11 | 133598.23 | 14-FEB-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.561477E+10 | 110446.38 | 15-MAR-06:53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.753301E+09 | 79758.94 | 05-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.162576E+09 | 33734.10 | 02-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 16629975.09 | 10832.36 | 03-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 415756.66 | 511.09 | 18-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 2237690.69 | 2361.00 | 18-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.174641E+09 | 28851.16 | 06-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.583400E+09 | 67213.74 | 30-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.343266E+10 | 69176.26 | 24-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.322848E+11 | 127543.55 | 20-DEC-08:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.111893E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 415756.66 | 511.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.488225E+11 | 136201.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_TOP VAV BOX REHEAT COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.202157E+11 | 81582.93 | 17-JAN-05:24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.116326E+11 | 81703.84 | 21-FEB-05:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.632389E+10 | 81552.14 | 17-MAR-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.140499E+10 | 81767.61 | 10-APR-05:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 56049984.21 | 63916.62 | 01-MAY-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.142965E+10 | 81796.94 | 30-OCT-05:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.723032E+10 | 81746.86 | 20-NOV-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.169693E+11 | 81664.94 | 05-DEC-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.652625E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.202157E+11 | 81796.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.225991E+11 | 18651.42 | 06-JAN-09:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.156964E+11 | 17491.70 | 14-FEB-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.107509E+11 | 17030.79 | 27-MAR-04:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.354658E+10 | 17027.53 | 17-APR-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.217300E+09 | 16911.92 | 01-MAY-04:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 1024870.32 | 282.22 | 10-JUN-05:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 12960311.86 | 2170.27 | 19-AUG-05:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.323526E+09 | 16929.54 | 20-SEP-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.335092E+10 | 17067.32 | 16-OCT-04:23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.994353E+10 | 17051.39 | 20-NOV-05:43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.212185E+11 | 17025.35 | 06-DEC-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.876607E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.225991E+11 | 18651.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.154101E+11 | 19340.24 | 31-JAN-05:14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.101751E+11 | 19377.28 | 07-FEB-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.674919E+10 | 19351.10 | 17-MAR-04:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.219176E+10 | 19379.41 | 04-APR-04:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.163658E+09 | 19179.19 | 01-MAY-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 41193308.25 | 2684.20 | 10-JUN-05:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 1569650.73 | 355.81 | 08-JUL-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 30629886.71 | 2695.42 | 19-AUG-05:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.467467E+09 | 17108.87 | 20-SEP-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.304753E+10 | 19443.41 | 30-OCT-03:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.738188E+10 | 19372.86 | 06-NOV-04:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.148375E+11 | 19386.22 | 29-DEC-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.604976E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 1569650.73 | 355.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.154101E+11 | 19443.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.168180E+11 | 24605.80 | 19-JAN-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.102681E+11 | 24592.42 | 08-FEB-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.735154E+10 | 24618.36 | 22-MAR-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.284976E+10 | 24528.43 | 05-APR-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.281289E+09 | 24265.48 | 01-MAY-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 27160260.17 | 2723.62 | 10-JUN-05:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 38989343.80 | 3808.20 | 19-AUG-05:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.388529E+09 | 21684.54 | 20-SEP-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.302812E+10 | 24564.28 | 30-OCT-03:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.802025E+10 | 24562.33 | 14-NOV-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.170597E+11 | 24595.86 | 06-DEC-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.661315E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.170597E+11 | 24618.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.146589E+11 | 21383.63 | 20-JAN-05:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.909033E+10 | 21347.83 | 11-FEB-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.619334E+10 | 21410.09 | 17-MAR-04:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.221340E+10 | 21299.45 | 04-APR-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.212557E+09 | 12799.40 | 09-MAY-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 35135454.14 | 2563.52 | 10-JUN-05:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 45656021.23 | 2677.62 | 19-AUG-05:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.461941E+09 | 13832.02 | 20-SEP-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.262179E+10 | 21349.28 | 10-OCT-04:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.638015E+10 | 21436.24 | 22-NOV-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.131673E+11 | 21375.45 | 01-DEC-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.550805E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.146589E+11 | 21436.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CAV_BAS HEATING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.110074E+10 | 32360.99 | 06-JAN-07:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.110074E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.110074E+10 | 32360.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: AIRLOOP DATACENTER BASEMENT HEATING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: AIRLOOP DATACENTER BOT HEATING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: AIRLOOP DATACENTER MID HEATING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: AIRLOOP DATACENTER TOP HEATING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: AIRLOOP DATACENTER BASEMENT_SUPPHEATCOIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: AIRLOOP DATACENTER BOT_SUPPHEATCOIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: AIRLOOP DATACENTER MID_SUPPHEATCOIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: AIRLOOP DATACENTER TOP_SUPPHEATCOIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: VAV_BOT WITH REHEAT COOLING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 7632888.20 | 7632888.20 | 3987.55 | 27-JAN-15:27 | 3987.55 | 0.00 |
February | 0.00 | 0.00 | 34631270.58 | 34631270.58 | 5531.22 | 10-FEB-15:30 | 5531.22 | 0.00 |
March | 0.00 | 0.00 | 0.126098E+09 | 0.126098E+09 | 32937.94 | 15-MAR-10:15 | 32937.94 | 0.00 |
April | 0.00 | 0.00 | 0.469924E+10 | 0.469924E+10 | 88947.90 | 23-APR-15:22 | 88947.90 | 0.01 |
May | 0.00 | 0.00 | 0.368903E+11 | 0.360394E+11 | 132925.20 | 26-MAY-11:00 | 87048.87 | 0.17 |
June | 0.00 | 0.00 | 0.880316E+11 | 0.698520E+11 | 216460.70 | 19-JUN-15:30 | 98060.82 | 0.42 |
July | 0.00 | 0.00 | 0.121069E+12 | 0.901913E+11 | 277290.80 | 05-JUL-10:30 | 99719.27 | 0.64 |
August | 0.00 | 0.00 | 0.946235E+11 | 0.706502E+11 | 229570.45 | 31-AUG-12:50 | 103411.06 | 0.63 |
September | 0.00 | 0.00 | 0.189854E+11 | 0.168612E+11 | 142763.41 | 01-SEP-13:10 | 103654.31 | 0.12 |
October | 0.00 | 0.00 | 0.321494E+10 | 0.321494E+10 | 75771.02 | 19-OCT-15:00 | 75771.02 | 0.01 |
November | 0.00 | 0.00 | 0.443683E+09 | 0.443683E+09 | 24618.16 | 01-NOV-15:00 | 24618.16 | 0.01 |
December | 0.00 | 0.00 | 29889424.99 | 29889424.99 | 5625.96 | 27-DEC-08:20 | 5625.96 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.368156E+12 | 0.292150E+12 | 0.17 | |||
Minimum of Months | 0.00 | 0.00 | 7632888.20 | 7632888.20 | 3987.55 | 3987.55 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.121069E+12 | 0.901913E+11 | 277290.80 | 103654.31 | 0.64 |
Report: CoilReportMonthly
For: VAV_MID WITH REHEAT COOLING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 1544876.73 | 1544876.73 | 459.60 | 27-JAN-13:10 | 459.60 | 0.00 |
February | 0.00 | 0.00 | 0.116206E+09 | 0.116206E+09 | 11481.26 | 08-FEB-14:00 | 11481.26 | 0.00 |
March | 0.00 | 0.00 | 0.152171E+09 | 0.152171E+09 | 28256.66 | 23-MAR-09:47 | 28256.66 | 0.00 |
April | 0.00 | 0.00 | 0.345965E+11 | 0.345965E+11 | 825591.51 | 23-APR-16:01 | 825591.51 | 0.01 |
May | 0.00 | 0.00 | 0.333085E+12 | 0.324811E+12 | 1265105.07 | 26-MAY-11:00 | 826727.40 | 0.17 |
June | 0.00 | 0.00 | 0.756544E+12 | 0.603393E+12 | 2248250.81 | 30-JUN-05:03 | 1433316.31 | 0.38 |
July | 0.00 | 0.00 | 0.969724E+12 | 0.742572E+12 | 2435409.55 | 05-JUL-10:35 | 865115.16 | 0.54 |
August | 0.00 | 0.00 | 0.731377E+12 | 0.556437E+12 | 1817441.51 | 31-AUG-12:50 | 823803.05 | 0.54 |
September | 0.00 | 0.00 | 0.165043E+12 | 0.148679E+12 | 1305593.53 | 01-SEP-12:20 | 896826.14 | 0.11 |
October | 0.00 | 0.00 | 0.286663E+11 | 0.286663E+11 | 617765.41 | 19-OCT-15:00 | 617765.41 | 0.01 |
November | 0.00 | 0.00 | 0.299395E+10 | 0.299395E+10 | 170758.86 | 01-NOV-15:00 | 170758.86 | 0.01 |
December | 0.00 | 0.00 | 2385345.96 | 2385345.96 | 302.53 | 30-DEC-08:50 | 302.53 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.302230E+13 | 0.244242E+13 | 0.15 | |||
Minimum of Months | 0.00 | 0.00 | 1544876.73 | 1544876.73 | 302.53 | 302.53 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.969724E+12 | 0.742572E+12 | 2435409.55 | 1433316.31 | 0.54 |
Report: CoilReportMonthly
For: VAV_TOP WITH REHEAT COOLING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 492153.63 | 492153.63 | 1893.40 | 24-JAN-05:51 | 1893.40 | 0.00 |
February | 0.00 | 0.00 | 6264841.43 | 6264841.43 | 1251.90 | 08-FEB-13:10 | 1251.90 | 0.00 |
March | 0.00 | 0.00 | 27947230.70 | 27947230.70 | 1704.86 | 28-MAR-15:50 | 1704.86 | 0.00 |
April | 0.00 | 0.00 | 0.320805E+10 | 0.320805E+10 | 92079.39 | 23-APR-15:51 | 92079.39 | 0.01 |
May | 0.00 | 0.00 | 0.354253E+11 | 0.345371E+11 | 141092.51 | 25-MAY-16:00 | 124206.22 | 0.17 |
June | 0.00 | 0.00 | 0.799198E+11 | 0.641583E+11 | 239595.05 | 30-JUN-05:03 | 149508.22 | 0.38 |
July | 0.00 | 0.00 | 0.103774E+12 | 0.794686E+11 | 247584.77 | 05-JUL-10:35 | 87923.37 | 0.54 |
August | 0.00 | 0.00 | 0.757541E+11 | 0.576696E+11 | 204143.50 | 29-AUG-15:40 | 118096.17 | 0.53 |
September | 0.00 | 0.00 | 0.155332E+11 | 0.140083E+11 | 150609.78 | 01-SEP-14:00 | 114345.72 | 0.11 |
October | 0.00 | 0.00 | 0.251675E+10 | 0.251675E+10 | 60717.96 | 19-OCT-15:00 | 60717.96 | 0.01 |
November | 0.00 | 0.00 | 0.261298E+09 | 0.261298E+09 | 14194.10 | 01-NOV-15:00 | 14194.10 | 0.01 |
December | 0.00 | 0.00 | 308613.59 | 308613.59 | 1060.07 | 15-DEC-04:42 | 1060.07 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.316427E+12 | 0.255863E+12 | 0.15 | |||
Minimum of Months | 0.00 | 0.00 | 308613.59 | 308613.59 | 1060.07 | 1060.07 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.103774E+12 | 0.794686E+11 | 247584.77 | 149508.22 | 0.54 |
Report: CoilReportMonthly
For: CAV_BAS COOLING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 28581521.05 | 28581521.05 | 6440.71 | 31-JAN-19:00 | 6440.71 | 0.00 |
February | 0.00 | 0.00 | 42141558.90 | 42141558.90 | 19797.47 | 13-FEB-11:00 | 19797.47 | 0.00 |
March | 0.00 | 0.00 | 27748330.04 | 27748330.04 | 5864.57 | 15-MAR-06:40 | 5864.57 | 0.00 |
April | 0.00 | 0.00 | 0.723343E+09 | 0.723343E+09 | 25909.14 | 13-APR-16:00 | 25909.14 | 0.00 |
May | 0.00 | 0.00 | 0.183804E+11 | 0.182400E+11 | 80258.35 | 26-MAY-04:02 | 54706.81 | 0.15 |
June | 0.00 | 0.00 | 0.415781E+11 | 0.353558E+11 | 185856.39 | 30-JUN-03:02 | 74075.49 | 0.30 |
July | 0.00 | 0.00 | 0.553168E+11 | 0.454479E+11 | 165160.68 | 05-JUL-10:10 | 60915.03 | 0.43 |
August | 0.00 | 0.00 | 0.449551E+11 | 0.361195E+11 | 116299.03 | 09-AUG-03:02 | 50865.07 | 0.42 |
September | 0.00 | 0.00 | 0.833262E+10 | 0.777328E+10 | 83563.97 | 01-SEP-03:52 | 31229.63 | 0.07 |
October | 0.00 | 0.00 | 0.112250E+10 | 0.112250E+10 | 43987.43 | 19-OCT-15:00 | 43987.43 | 0.00 |
November | 0.00 | 0.00 | 0.158960E+09 | 0.157626E+09 | 13322.08 | 21-NOV-06:03 | 8016.44 | 0.01 |
December | 0.00 | 0.00 | 56930004.98 | 56930004.98 | 26701.47 | 18-DEC-16:30 | 26701.47 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.170723E+12 | 0.145095E+12 | 0.12 | |||
Minimum of Months | 0.00 | 0.00 | 27748330.04 | 27748330.04 | 5864.57 | 5864.57 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.553168E+11 | 0.454479E+11 | 185856.39 | 74075.49 | 0.43 |
Report: CoilReportMonthly
For: AIRLOOP DATACENTER BASEMENT COOLING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.308505E+12 | 0.308499E+12 | 124662.62 | 20-JAN-22:10 | 124662.62 | 0.00 |
February | 0.00 | 0.00 | 0.503923E+12 | 0.503923E+12 | 216420.11 | 22-FEB-22:10 | 216420.11 | 0.00 |
March | 0.00 | 0.00 | 0.806810E+12 | 0.806810E+12 | 395074.20 | 31-MAR-24:00 | 395074.20 | 0.00 |
April | 0.00 | 0.00 | 0.102578E+13 | 0.102578E+13 | 403884.58 | 23-APR-20:03 | 403884.58 | 0.00 |
May | 0.00 | 0.00 | 0.334445E+12 | 0.333146E+12 | 212009.76 | 31-MAY-24:00 | 212009.76 | 0.00 |
June | 0.00 | 0.00 | 0.566959E+12 | 0.561818E+12 | 305731.19 | 30-JUN-24:00 | 304778.14 | 0.00 |
July | 0.00 | 0.00 | 0.835293E+12 | 0.828757E+12 | 396893.33 | 31-JUL-24:00 | 396893.33 | 0.00 |
August | 0.00 | 0.00 | 0.107892E+13 | 0.107292E+13 | 417656.46 | 25-AUG-19:00 | 406101.92 | 0.00 |
September | 0.00 | 0.00 | 0.325809E+12 | 0.324275E+12 | 212604.82 | 30-SEP-24:00 | 212604.82 | 0.00 |
October | 0.00 | 0.00 | 0.574629E+12 | 0.574514E+12 | 303991.45 | 31-OCT-24:00 | 303991.45 | 0.00 |
November | 0.00 | 0.00 | 0.788135E+12 | 0.787998E+12 | 312382.01 | 21-NOV-14:10 | 307151.65 | 0.00 |
December | 0.00 | 0.00 | 0.104947E+13 | 0.104947E+13 | 401388.80 | 08-DEC-22:02 | 401388.80 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.819868E+13 | 0.817792E+13 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.308505E+12 | 0.308499E+12 | 124662.62 | 124662.62 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.107892E+13 | 0.107292E+13 | 417656.46 | 406101.92 | 0.00 |
Report: CoilReportMonthly
For: AIRLOOP DATACENTER BOT COOLING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.195333E+10 | 0.195331E+10 | 1958.26 | 20-JAN-16:30 | 1958.26 | 0.00 |
February | 0.00 | 0.00 | 0.753800E+10 | 0.753800E+10 | 4416.73 | 20-FEB-16:45 | 4416.73 | 0.00 |
March | 0.00 | 0.00 | 0.143917E+11 | 0.143917E+11 | 7653.38 | 31-MAR-24:00 | 7653.38 | 0.00 |
April | 0.00 | 0.00 | 0.197991E+11 | 0.197991E+11 | 8801.65 | 16-APR-18:03 | 8801.65 | 0.00 |
May | 0.00 | 0.00 | 0.589576E+10 | 0.584964E+10 | 3878.16 | 31-MAY-24:00 | 3878.16 | 0.00 |
June | 0.00 | 0.00 | 0.109648E+11 | 0.107624E+11 | 5996.22 | 30-JUN-23:03 | 5943.05 | 0.00 |
July | 0.00 | 0.00 | 0.165799E+11 | 0.163071E+11 | 7840.36 | 31-JUL-23:42 | 7840.36 | 0.00 |
August | 0.00 | 0.00 | 0.214782E+11 | 0.212062E+11 | 8956.87 | 25-AUG-18:20 | 8702.33 | 0.00 |
September | 0.00 | 0.00 | 0.548185E+10 | 0.542338E+10 | 3912.08 | 30-SEP-24:00 | 3912.08 | 0.00 |
October | 0.00 | 0.00 | 0.101025E+11 | 0.100967E+11 | 5455.69 | 31-OCT-24:00 | 5455.69 | 0.00 |
November | 0.00 | 0.00 | 0.140289E+11 | 0.140237E+11 | 6381.18 | 12-NOV-15:54 | 6381.18 | 0.00 |
December | 0.00 | 0.00 | 0.184210E+11 | 0.184210E+11 | 7772.57 | 10-DEC-15:53 | 7772.57 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.146635E+12 | 0.145772E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.195333E+10 | 0.195331E+10 | 1958.26 | 1958.26 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.214782E+11 | 0.212062E+11 | 8956.87 | 8801.65 | 0.00 |
Report: CoilReportMonthly
For: AIRLOOP DATACENTER MID COOLING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.216893E+10 | 0.216893E+10 | 14788.09 | 20-JAN-16:30 | 14788.09 | 0.00 |
February | 0.00 | 0.00 | 0.478589E+11 | 0.478589E+11 | 39265.14 | 08-FEB-17:00 | 39265.14 | 0.00 |
March | 0.00 | 0.00 | 0.117370E+12 | 0.117370E+12 | 68899.94 | 31-MAR-23:30 | 68899.94 | 0.00 |
April | 0.00 | 0.00 | 0.176203E+12 | 0.176203E+12 | 83362.73 | 21-APR-18:10 | 83362.73 | 0.00 |
May | 0.00 | 0.00 | 0.516839E+11 | 0.512300E+11 | 34672.67 | 31-MAY-24:00 | 34672.67 | 0.00 |
June | 0.00 | 0.00 | 0.101645E+12 | 0.996409E+11 | 58589.68 | 30-JUN-24:00 | 58347.36 | 0.00 |
July | 0.00 | 0.00 | 0.157439E+12 | 0.154724E+12 | 74897.24 | 31-JUL-23:55 | 74897.24 | 0.00 |
August | 0.00 | 0.00 | 0.202604E+12 | 0.199890E+12 | 85518.78 | 25-AUG-18:20 | 82996.17 | 0.00 |
September | 0.00 | 0.00 | 0.451456E+11 | 0.445810E+11 | 34440.44 | 30-SEP-23:50 | 34440.44 | 0.00 |
October | 0.00 | 0.00 | 0.813543E+11 | 0.812969E+11 | 44888.32 | 31-OCT-24:00 | 44888.32 | 0.00 |
November | 0.00 | 0.00 | 0.110173E+12 | 0.110121E+12 | 56339.68 | 17-NOV-16:10 | 56339.68 | 0.00 |
December | 0.00 | 0.00 | 0.143349E+12 | 0.143349E+12 | 65975.71 | 08-DEC-15:50 | 65975.71 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.123700E+13 | 0.122843E+13 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.216893E+10 | 0.216893E+10 | 14788.09 | 14788.09 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.202604E+12 | 0.199890E+12 | 85518.78 | 83362.73 | 0.00 |
Report: CoilReportMonthly
For: AIRLOOP DATACENTER TOP COOLING COIL
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 66495916.64 | 66495916.64 | 1237.03 | 20-JAN-16:30 | 1237.03 | 0.00 |
February | 0.00 | 0.00 | 0.309261E+10 | 0.309261E+10 | 3839.27 | 08-FEB-17:00 | 3839.27 | 0.00 |
March | 0.00 | 0.00 | 0.989801E+10 | 0.989801E+10 | 6426.44 | 31-MAR-23:20 | 6426.44 | 0.00 |
April | 0.00 | 0.00 | 0.162555E+11 | 0.162555E+11 | 8313.66 | 21-APR-18:10 | 8313.66 | 0.00 |
May | 0.00 | 0.00 | 0.468971E+10 | 0.464434E+10 | 3290.20 | 25-MAY-18:40 | 3147.27 | 0.00 |
June | 0.00 | 0.00 | 0.993960E+10 | 0.973964E+10 | 5799.86 | 30-JUN-24:00 | 5775.61 | 0.00 |
July | 0.00 | 0.00 | 0.156509E+11 | 0.153797E+11 | 7409.80 | 31-JUL-23:55 | 7409.80 | 0.00 |
August | 0.00 | 0.00 | 0.200852E+11 | 0.198140E+11 | 8624.10 | 25-AUG-18:20 | 8371.60 | 0.00 |
September | 0.00 | 0.00 | 0.386866E+10 | 0.381335E+10 | 3176.07 | 03-SEP-17:43 | 3161.20 | 0.00 |
October | 0.00 | 0.00 | 0.653324E+10 | 0.652762E+10 | 4485.46 | 19-OCT-16:40 | 4423.81 | 0.00 |
November | 0.00 | 0.00 | 0.901172E+10 | 0.900662E+10 | 5490.16 | 17-NOV-16:00 | 5490.16 | 0.00 |
December | 0.00 | 0.00 | 0.125139E+11 | 0.125139E+11 | 6277.05 | 28-DEC-15:30 | 6277.05 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.111606E+12 | 0.110752E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 66495916.64 | 66495916.64 | 1237.03 | 1237.03 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.200852E+11 | 0.198140E+11 | 8624.10 | 8371.60 | 0.00 |
Report: PlantLoopDemandReportMonthly
For: HEATSYS1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:01 | 398880.13 | 2932018.98 | 09-JAN-07:02 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 203518.46 | 2613590.94 | 14-FEB-07:03 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 86814.33 | 1890457.93 | 15-MAR-06:53 |
April | 0.00 | 0.00 | 01-APR-00:10 | 24930.35 | 1599543.07 | 10-APR-04:01 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 1758.70 | 417584.55 | 02-MAY-06:10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 88.70 | 103021.68 | 03-JUN-06:10 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.65 | 456.63 | 18-JUL-06:10 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 87.77 | 105376.01 | 19-AUG-06:13 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 2541.47 | 354752.20 | 06-SEP-06:10 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 25072.58 | 1604183.06 | 30-OCT-04:01 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 87538.56 | 2135164.95 | 27-NOV-05:11 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 295406.17 | 2575060.47 | 26-DEC-07:03 |
Annual Sum or Average | 0.00 | 93698.96 | ||||
Minimum of Months | 0.00 | 0.00 | 0.65 | 456.63 | ||
Maximum of Months | 0.00 | 0.00 | 398880.13 | 2932018.98 |
Report: PlantLoopDemandReportMonthly
For: COOLSYS1_SUPPLY
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 5165.06 | 28714.76 | 19-JAN-07:20 | 0.00 | 0.00 | 01-JAN-00:01 |
February | 6141.75 | 36135.83 | 13-FEB-11:00 | 0.00 | 0.00 | 01-FEB-00:03 |
March | 6570.06 | 62493.33 | 27-MAR-13:50 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 37643.50 | 1220854.84 | 13-APR-15:20 | 0.00 | 0.00 | 01-APR-00:10 |
May | 244402.27 | 1597391.89 | 26-MAY-11:00 | 18.01 | 147566.04 | 29-MAY-12:32 |
June | 519311.93 | 2421629.00 | 30-JUN-05:03 | 7.76 | 64350.57 | 04-JUN-19:33 |
July | 636516.18 | 5459282.62 | 05-JUL-11:00 | 33.17 | 110791.60 | 12-JUL-23:32 |
August | 505956.63 | 2299141.97 | 31-AUG-12:50 | 0.97 | 6771.05 | 21-AUG-23:32 |
September | 144765.73 | 1686810.95 | 07-SEP-14:10 | 27.77 | 131397.02 | 25-SEP-03:02 |
October | 28219.55 | 1374045.18 | 19-OCT-13:50 | 17.75 | 119052.27 | 01-OCT-10:08 |
November | 6975.89 | 473592.46 | 01-NOV-15:00 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 6208.27 | 50944.36 | 18-DEC-16:30 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 180430.30 | 8.86 | ||||
Minimum of Months | 5165.06 | 28714.76 | 0.00 | 0.00 | ||
Maximum of Months | 636516.18 | 5459282.62 | 33.17 | 147566.04 |
Report: PlantLoopDemandReportMonthly
For: COOLSYS1_DEMAND
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.85 | 615.25 | 31-JAN-19:00 | 0.00 | 0.00 | 01-JAN-00:01 |
February | 47.56 | 8425.01 | 08-FEB-14:10 | 0.00 | 0.00 | 01-FEB-00:03 |
March | 143.60 | 36114.73 | 31-MAR-10:45 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 20947.96 | 1417520.36 | 23-APR-14:42 | 0.00 | 0.00 | 01-APR-00:10 |
May | 191151.47 | 1902516.89 | 26-MAY-05:03 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 435288.69 | 3743330.09 | 30-JUN-05:03 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 552059.58 | 5623783.04 | 05-JUL-11:00 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 419190.91 | 2968928.29 | 09-AUG-03:02 | 0.00 | 0.00 | 01-AUG-00:03 |
September | 101076.21 | 1779786.75 | 19-SEP-05:03 | 0.00 | 0.00 | 01-SEP-00:03 |
October | 17205.91 | 977749.51 | 19-OCT-14:00 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 2101.11 | 309370.26 | 01-NOV-15:00 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 26.32 | 19988.86 | 18-DEC-16:30 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 146183.26 | 0.00 | ||||
Minimum of Months | 0.85 | 615.25 | 0.00 | 0.00 | ||
Maximum of Months | 552059.58 | 5623783.04 | 0.00 | 0.00 |
Report: PlantLoopDemandReportMonthly
For: SINGLE WATER PLANT LOOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 150028.33 | 296611.85 | 25-JAN-15:43 | 0.00 | 0.00 | 01-JAN-00:01 |
February | 293909.57 | 412781.96 | 22-FEB-16:00 | 0.00 | 0.00 | 01-FEB-00:03 |
March | 443705.32 | 594808.65 | 31-MAR-24:00 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 621097.98 | 1399092.15 | 23-APR-16:00 | 0.00 | 0.00 | 01-APR-00:10 |
May | 267419.46 | 904144.67 | 25-MAY-18:00 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 551963.69 | 1475360.49 | 29-JUN-16:00 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 815115.49 | 1467549.18 | 15-JUL-14:40 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 922643.26 | 1660578.45 | 08-AUG-16:00 | 0.00 | 0.00 | 01-AUG-00:03 |
September | 215981.92 | 734940.74 | 01-SEP-16:00 | 0.00 | 0.00 | 01-SEP-00:03 |
October | 323135.21 | 712787.94 | 19-OCT-15:00 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 446877.54 | 702506.31 | 01-NOV-15:00 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 569598.78 | 594128.28 | 14-DEC-13:03 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 469994.86 | 0.00 | ||||
Minimum of Months | 150028.33 | 296611.85 | 0.00 | 0.00 | ||
Maximum of Months | 922643.26 | 1660578.45 | 0.00 | 0.00 |
Report: PlantLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:01 | 18370.14 | 62713.90 | 31-JAN-12:40 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 18862.74 | 63343.77 | 24-FEB-12:10 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 19880.52 | 63281.93 | 01-MAR-12:30 |
April | 0.00 | 0.00 | 01-APR-00:10 | 18198.48 | 62040.70 | 03-APR-11:50 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 17892.96 | 59652.86 | 01-MAY-11:40 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 17285.79 | 56296.47 | 01-JUN-11:50 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15251.48 | 52971.21 | 03-JUL-12:00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 16128.02 | 50944.40 | 01-AUG-11:20 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 15283.30 | 51365.12 | 29-SEP-11:30 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 15803.41 | 54021.31 | 31-OCT-12:00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 16858.26 | 57284.30 | 30-NOV-12:30 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 17192.01 | 60312.65 | 29-DEC-13:00 |
Annual Sum or Average | 0.00 | 17241.11 | ||||
Minimum of Months | 0.00 | 0.00 | 15251.48 | 50944.40 | ||
Maximum of Months | 0.00 | 0.00 | 19880.52 | 63343.77 |
Report: PlantLoopDemandReportMonthly
For: TOWERWATERSYS
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 529.80 | 29653.99 | 10-JAN-19:20 | 4609.19 | 149394.77 | 21-JAN-07:30 |
February | 564.29 | 29738.34 | 14-FEB-20:40 | 5910.30 | 150482.62 | 28-FEB-06:50 |
March | 540.88 | 30213.41 | 28-MAR-13:20 | 6743.09 | 149223.15 | 21-MAR-12:13 |
April | 20198.57 | 715828.54 | 13-APR-15:20 | 3156.16 | 151256.84 | 19-APR-08:00 |
May | 216932.59 | 3230060.16 | 25-MAY-16:00 | 666.71 | 111330.17 | 20-MAY-07:10 |
June | 682339.07 | 6291161.38 | 30-JUN-16:00 | 234.59 | 66338.02 | 02-JUN-15:50 |
July | 865647.56 | 7053767.69 | 05-JUL-11:00 | 175.40 | 37344.99 | 10-JUL-05:40 |
August | 598449.92 | 5482705.63 | 31-AUG-12:50 | 385.93 | 54421.40 | 05-AUG-20:50 |
September | 106153.65 | 2783541.01 | 01-SEP-12:20 | 764.54 | 109761.64 | 23-SEP-05:40 |
October | 16383.11 | 933971.54 | 19-OCT-14:30 | 2218.16 | 134227.99 | 30-OCT-06:20 |
November | 2273.39 | 306653.19 | 01-NOV-15:00 | 4058.89 | 148131.09 | 08-NOV-12:30 |
December | 611.96 | 29746.63 | 13-DEC-20:30 | 5739.91 | 150851.26 | 26-DEC-15:10 |
Annual Sum or Average | 211004.69 | 2872.89 | ||||
Minimum of Months | 529.80 | 29653.99 | 175.40 | 37344.99 | ||
Maximum of Months | 865647.56 | 7053767.69 | 6743.09 | 151256.84 |
Report: FanReportMonthly
For: CAV_BAS FAN
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.139205E+11 | 0.76 | 10020.67 | 02-JAN-06:01 | 1.43 |
February | 0.130681E+11 | 0.79 | 10020.67 | 01-FEB-06:03 | 1.46 |
March | 0.157664E+11 | 0.85 | 10020.67 | 01-MAR-05:01 | 1.46 |
April | 0.147374E+11 | 0.83 | 10020.67 | 01-APR-04:02 | 1.45 |
May | 0.160316E+11 | 0.86 | 10020.67 | 01-MAY-03:02 | 1.46 |
June | 0.157615E+11 | 0.87 | 10020.67 | 01-JUN-03:02 | 1.44 |
July | 0.155023E+11 | 0.83 | 10020.67 | 01-JUL-03:02 | 1.44 |
August | 0.171666E+11 | 0.92 | 10020.67 | 01-AUG-03:02 | 1.44 |
September | 0.159590E+11 | 0.89 | 10020.67 | 01-SEP-03:05 | 1.43 |
October | 0.157344E+11 | 0.85 | 10020.67 | 02-OCT-00:30 | 1.44 |
November | 0.147632E+11 | 0.83 | 10020.67 | 01-NOV-03:20 | 1.46 |
December | 0.143139E+11 | 0.78 | 10020.67 | 01-DEC-05:01 | 1.46 |
Annual Sum or Average | 0.182725E+12 | 0.84 | |||
Minimum of Months | 0.130681E+11 | 0.76 | 10020.67 | 1.43 | |
Maximum of Months | 0.171666E+11 | 0.92 | 10020.67 | 1.46 |
Report: FanReportMonthly
For: VAV_BOT WITH REHEAT FAN
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.404957E+10 | 0.34 | 16360.84 | 26-JAN-15:37 | 1.57 |
February | 0.462838E+10 | 0.36 | 22427.16 | 27-FEB-15:07 | 1.92 |
March | 0.702940E+10 | 0.43 | 22427.16 | 02-MAR-14:50 | 1.92 |
April | 0.892521E+10 | 0.50 | 21270.88 | 05-APR-10:30 | 1.86 |
May | 0.988380E+10 | 0.53 | 15859.61 | 18-MAY-14:50 | 1.52 |
June | 0.124480E+11 | 0.63 | 22956.73 | 27-JUN-05:03 | 1.93 |
July | 0.144340E+11 | 0.69 | 22956.73 | 05-JUL-10:40 | 1.91 |
August | 0.142665E+11 | 0.70 | 22956.73 | 01-AUG-05:03 | 1.92 |
September | 0.828192E+10 | 0.48 | 18565.21 | 01-SEP-15:50 | 1.68 |
October | 0.691455E+10 | 0.42 | 14561.53 | 17-OCT-17:40 | 1.46 |
November | 0.587275E+10 | 0.38 | 16360.84 | 07-NOV-10:10 | 1.57 |
December | 0.479042E+10 | 0.35 | 16360.84 | 01-DEC-10:30 | 1.57 |
Annual Sum or Average | 0.101525E+12 | 0.49 | |||
Minimum of Months | 0.404957E+10 | 0.34 | 14561.53 | 1.46 | |
Maximum of Months | 0.144340E+11 | 0.70 | 22956.73 | 1.93 |
Report: FanReportMonthly
For: VAV_MID WITH REHEAT FAN
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.498525E+11 | 0.44 | 56375.90 | 02-JAN-04:01 | 0.87 |
February | 0.408363E+11 | 0.40 | 56375.90 | 13-FEB-06:01 | 0.87 |
March | 0.458736E+11 | 0.38 | 214307.39 | 23-MAR-10:10 | 1.96 |
April | 0.527474E+11 | 0.39 | 187609.44 | 04-APR-15:10 | 1.80 |
May | 0.818606E+11 | 0.48 | 165870.83 | 18-MAY-14:40 | 1.64 |
June | 0.996686E+11 | 0.56 | 214307.39 | 30-JUN-05:03 | 1.94 |
July | 0.109703E+12 | 0.57 | 214307.39 | 05-JUL-10:40 | 1.92 |
August | 0.953079E+11 | 0.54 | 176509.01 | 08-AUG-15:20 | 1.71 |
September | 0.641107E+11 | 0.43 | 157190.84 | 01-SEP-16:00 | 1.59 |
October | 0.464184E+11 | 0.35 | 164954.52 | 25-OCT-09:57 | 1.65 |
November | 0.390560E+11 | 0.35 | 113056.95 | 03-NOV-11:00 | 1.31 |
December | 0.474005E+11 | 0.43 | 56375.90 | 04-DEC-05:01 | 0.87 |
Annual Sum or Average | 0.772836E+12 | 0.44 | |||
Minimum of Months | 0.390560E+11 | 0.35 | 56375.90 | 0.87 | |
Maximum of Months | 0.109703E+12 | 0.57 | 214307.39 | 1.96 |
Report: FanReportMonthly
For: VAV_TOP WITH REHEAT FAN
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.597878E+10 | 0.50 | 5537.24 | 02-JAN-04:01 | 0.83 |
February | 0.509526E+10 | 0.47 | 5537.24 | 01-FEB-05:01 | 0.83 |
March | 0.492887E+10 | 0.42 | 5537.24 | 01-MAR-06:01 | 0.83 |
April | 0.465357E+10 | 0.37 | 20055.47 | 20-APR-10:37 | 1.80 |
May | 0.732586E+10 | 0.43 | 19460.97 | 18-MAY-14:40 | 1.74 |
June | 0.967919E+10 | 0.52 | 22805.78 | 30-JUN-05:03 | 1.93 |
July | 0.107454E+11 | 0.53 | 22805.78 | 05-JUL-10:45 | 1.91 |
August | 0.882940E+10 | 0.49 | 19942.29 | 08-AUG-15:20 | 1.77 |
September | 0.527073E+10 | 0.37 | 17821.82 | 01-SEP-16:00 | 1.64 |
October | 0.413026E+10 | 0.34 | 8538.64 | 20-OCT-15:00 | 1.06 |
November | 0.478533E+10 | 0.42 | 5537.24 | 04-NOV-05:01 | 0.83 |
December | 0.576076E+10 | 0.48 | 5537.24 | 01-DEC-05:01 | 0.83 |
Annual Sum or Average | 0.771834E+11 | 0.45 | |||
Minimum of Months | 0.413026E+10 | 0.34 | 5537.24 | 0.83 | |
Maximum of Months | 0.107454E+11 | 0.53 | 22805.78 | 1.93 |
Report: FanReportMonthly
For: AIRLOOP DATACENTER BASEMENT SUPPLY FAN
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.984279E+11 | 1.40 | 36748.76 | 01-JAN-00:01 | 1.40 |
February | 0.889026E+11 | 1.40 | 36748.76 | 01-FEB-00:03 | 1.40 |
March | 0.984279E+11 | 1.40 | 36748.76 | 01-MAR-00:10 | 1.40 |
April | 0.952528E+11 | 1.40 | 36748.76 | 01-APR-00:10 | 1.40 |
May | 0.984279E+11 | 1.40 | 36748.76 | 01-MAY-00:10 | 1.40 |
June | 0.952528E+11 | 1.40 | 36748.76 | 01-JUN-00:10 | 1.40 |
July | 0.984279E+11 | 1.40 | 36748.76 | 01-JUL-00:10 | 1.40 |
August | 0.984279E+11 | 1.40 | 36748.76 | 01-AUG-00:03 | 1.40 |
September | 0.952528E+11 | 1.40 | 36748.76 | 01-SEP-00:03 | 1.40 |
October | 0.984279E+11 | 1.40 | 36748.76 | 01-OCT-00:10 | 1.40 |
November | 0.952528E+11 | 1.40 | 36748.76 | 01-NOV-00:10 | 1.40 |
December | 0.984279E+11 | 1.40 | 36748.76 | 01-DEC-00:10 | 1.40 |
Annual Sum or Average | 0.115891E+13 | 1.40 | |||
Minimum of Months | 0.889026E+11 | 1.40 | 36748.76 | 1.40 | |
Maximum of Months | 0.984279E+11 | 1.40 | 36748.76 | 1.40 |
Report: FanReportMonthly
For: AIRLOOP DATACENTER BOT SUPPLY FAN
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.157337E+10 | 0.96 | 587.43 | 01-JAN-00:01 | 0.95 |
February | 0.142110E+10 | 0.96 | 587.43 | 01-FEB-00:08 | 0.96 |
March | 0.157337E+10 | 0.96 | 587.43 | 01-MAR-00:10 | 0.96 |
April | 0.152261E+10 | 0.96 | 587.43 | 01-APR-00:10 | 0.96 |
May | 0.157337E+10 | 0.95 | 587.43 | 01-MAY-00:10 | 0.96 |
June | 0.152261E+10 | 0.95 | 587.43 | 01-JUN-00:10 | 0.95 |
July | 0.157337E+10 | 0.95 | 587.43 | 01-JUL-00:10 | 0.95 |
August | 0.157337E+10 | 0.95 | 587.43 | 01-AUG-00:03 | 0.95 |
September | 0.152261E+10 | 0.95 | 587.43 | 01-SEP-00:03 | 0.95 |
October | 0.157337E+10 | 0.96 | 587.43 | 01-OCT-00:10 | 0.95 |
November | 0.152261E+10 | 0.96 | 587.43 | 01-NOV-00:10 | 0.96 |
December | 0.157337E+10 | 0.96 | 587.43 | 01-DEC-00:10 | 0.96 |
Annual Sum or Average | 0.185251E+11 | 0.96 | |||
Minimum of Months | 0.142110E+10 | 0.95 | 587.43 | 0.95 | |
Maximum of Months | 0.157337E+10 | 0.96 | 587.43 | 0.96 |
Report: FanReportMonthly
For: AIRLOOP DATACENTER MID SUPPLY FAN
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.150825E+11 | 0.96 | 5631.17 | 01-JAN-00:01 | 0.96 |
February | 0.136229E+11 | 0.96 | 5631.17 | 01-FEB-00:03 | 0.96 |
March | 0.150825E+11 | 0.96 | 5631.17 | 01-MAR-00:10 | 0.96 |
April | 0.145960E+11 | 0.96 | 5631.17 | 01-APR-00:10 | 0.96 |
May | 0.150825E+11 | 0.95 | 5631.17 | 01-MAY-00:10 | 0.96 |
June | 0.145960E+11 | 0.95 | 5631.17 | 01-JUN-00:10 | 0.95 |
July | 0.150825E+11 | 0.95 | 5631.17 | 01-JUL-00:10 | 0.95 |
August | 0.150825E+11 | 0.95 | 5631.17 | 01-AUG-00:03 | 0.95 |
September | 0.145960E+11 | 0.95 | 5631.17 | 01-SEP-00:03 | 0.95 |
October | 0.150825E+11 | 0.96 | 5631.17 | 01-OCT-00:30 | 0.95 |
November | 0.145960E+11 | 0.96 | 5631.17 | 01-NOV-00:10 | 0.96 |
December | 0.150825E+11 | 0.96 | 5631.17 | 01-DEC-00:10 | 0.96 |
Annual Sum or Average | 0.177584E+12 | 0.96 | |||
Minimum of Months | 0.136229E+11 | 0.95 | 5631.17 | 0.95 | |
Maximum of Months | 0.150825E+11 | 0.96 | 5631.17 | 0.96 |
Report: FanReportMonthly
For: AIRLOOP DATACENTER TOP SUPPLY FAN
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.152966E+10 | 0.96 | 571.11 | 01-JAN-00:01 | 0.96 |
February | 0.138163E+10 | 0.96 | 571.11 | 01-FEB-00:03 | 0.96 |
March | 0.152966E+10 | 0.96 | 571.11 | 01-MAR-00:10 | 0.96 |
April | 0.148031E+10 | 0.96 | 571.11 | 01-APR-00:10 | 0.96 |
May | 0.152966E+10 | 0.95 | 571.11 | 01-MAY-00:10 | 0.96 |
June | 0.148031E+10 | 0.95 | 571.11 | 01-JUN-00:10 | 0.95 |
July | 0.152966E+10 | 0.95 | 571.11 | 01-JUL-00:10 | 0.95 |
August | 0.152966E+10 | 0.95 | 571.11 | 01-AUG-00:03 | 0.95 |
September | 0.148031E+10 | 0.95 | 571.11 | 01-SEP-00:03 | 0.95 |
October | 0.152966E+10 | 0.96 | 571.11 | 01-OCT-00:10 | 0.95 |
November | 0.148031E+10 | 0.96 | 571.11 | 01-NOV-00:10 | 0.96 |
December | 0.152966E+10 | 0.96 | 571.11 | 01-DEC-00:10 | 0.96 |
Annual Sum or Average | 0.180105E+11 | 0.96 | |||
Minimum of Months | 0.138163E+10 | 0.95 | 571.11 | 0.95 | |
Maximum of Months | 0.152966E+10 | 0.96 | 571.11 | 0.96 |
Report: PumpReportMonthly
For: HEATSYS1 PUMP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.454403E+10 | 0.408963E+10 | 7913.76 | 09-JAN-07:03 | 7122.38 | 7122.38 | 50.96 | 21.30 |
February | 0.212174E+10 | 0.190956E+10 | 7586.48 | 14-FEB-07:10 | 6827.83 | 6827.83 | 52.25 | 17.64 |
March | 0.101536E+10 | 0.913828E+09 | 6698.80 | 06-MAR-06:03 | 6028.92 | 6028.92 | 47.57 | 11.98 |
April | 0.289041E+09 | 0.260137E+09 | 5130.63 | 10-APR-05:01 | 4617.57 | 4617.57 | 37.14 | 7.34 |
May | 20303899.71 | 18273509.74 | 1719.45 | 02-MAY-06:10 | 1547.51 | 1547.51 | 28.55 | 1.91 |
June | 992373.01 | 893135.71 | 440.77 | 03-JUN-06:10 | 396.69 | 396.69 | 25.95 | 0.46 |
July | 7360.93 | 6624.84 | 1.94 | 18-JUL-06:10 | 1.75 | 1.75 | 24.23 | 0.00 |
August | 974071.98 | 876664.78 | 426.11 | 19-AUG-06:13 | 383.50 | 383.50 | 23.04 | 0.44 |
September | 27854964.60 | 25069468.14 | 1403.57 | 06-SEP-06:10 | 1263.21 | 1263.21 | 25.31 | 1.53 |
October | 0.292061E+09 | 0.262855E+09 | 5092.67 | 16-OCT-05:01 | 4583.40 | 4583.40 | 31.46 | 7.28 |
November | 0.100475E+10 | 0.904279E+09 | 6728.92 | 28-NOV-06:01 | 6056.03 | 6056.03 | 43.28 | 12.13 |
December | 0.340614E+10 | 0.306552E+10 | 7688.26 | 26-DEC-07:03 | 6919.43 | 6919.43 | 49.32 | 18.73 |
Annual Sum or Average | 0.127233E+11 | 0.114509E+11 | ||||||
Minimum of Months | 7360.93 | 6624.84 | 1.94 | 1.75 | 1.75 | 23.04 | 0.00 | |
Maximum of Months | 0.454403E+10 | 0.408963E+10 | 7913.76 | 7122.38 | 7122.38 | 52.25 | 21.30 |
Report: PumpReportMonthly
For: COOLSYS1 PUMP SECONDARY
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 3470.30 | 3123.27 | 0.51 | 27-JAN-15:27 | 0.46 | 0.46 | 6.83 | 0.12 |
February | 38558.22 | 34702.40 | 3.41 | 08-FEB-14:00 | 3.07 | 3.07 | 7.39 | 0.71 |
March | 61347.70 | 55212.93 | 6.73 | 31-MAR-10:45 | 6.06 | 6.06 | 8.35 | 1.29 |
April | 24633236.81 | 22169913.13 | 4575.33 | 23-APR-15:22 | 4117.80 | 4117.80 | 7.65 | 57.48 |
May | 0.529659E+09 | 0.476693E+09 | 5465.54 | 26-MAY-05:03 | 4918.98 | 4918.98 | 8.09 | 61.98 |
June | 0.120269E+10 | 0.108242E+10 | 21903.62 | 30-JUN-05:03 | 19713.26 | 19713.26 | 7.34 | 108.99 |
July | 0.200995E+10 | 0.180895E+10 | 23053.48 | 05-JUL-10:35 | 20748.13 | 20748.13 | 10.47 | 111.21 |
August | 0.118899E+10 | 0.107009E+10 | 11366.53 | 09-AUG-05:03 | 10229.88 | 10229.88 | 8.38 | 83.89 |
September | 0.236206E+09 | 0.212585E+09 | 5697.48 | 01-SEP-12:20 | 5127.73 | 5127.73 | 7.12 | 63.08 |
October | 24117533.17 | 21705779.85 | 1006.05 | 22-OCT-13:02 | 905.44 | 905.44 | 8.35 | 29.14 |
November | 2379822.52 | 2141840.27 | 164.47 | 01-NOV-15:00 | 148.02 | 148.02 | 8.48 | 11.53 |
December | 11049.35 | 9944.42 | 3.34 | 18-DEC-16:30 | 3.01 | 3.01 | 8.42 | 0.70 |
Annual Sum or Average | 0.521874E+10 | 0.469687E+10 | ||||||
Minimum of Months | 3470.30 | 3123.27 | 0.51 | 0.46 | 0.46 | 6.83 | 0.12 | |
Maximum of Months | 0.200995E+10 | 0.180895E+10 | 23053.48 | 20748.13 | 20748.13 | 10.47 | 111.21 |
Report: PumpReportMonthly
For: COOLSYS1 PUMP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.773353E+10 | 0.696018E+10 | 15867.08 | 02-JAN-15:10 | 14280.38 | 14280.38 | 8.42 | 111.21 |
February | 0.823867E+10 | 0.741480E+10 | 15867.08 | 01-FEB-07:03 | 14280.38 | 14280.38 | 8.43 | 111.21 |
March | 0.950998E+10 | 0.855898E+10 | 15867.08 | 01-MAR-07:40 | 14280.38 | 14280.38 | 8.43 | 111.21 |
April | 0.650430E+10 | 0.585387E+10 | 15867.08 | 03-APR-04:01 | 14280.38 | 14280.38 | 8.44 | 111.21 |
May | 0.141418E+11 | 0.127277E+11 | 15867.08 | 01-MAY-06:05 | 14280.38 | 14280.38 | 8.43 | 111.21 |
June | 0.232658E+11 | 0.209392E+11 | 15867.08 | 01-JUN-04:02 | 14280.38 | 14280.38 | 9.25 | 111.21 |
July | 0.287737E+11 | 0.258963E+11 | 15867.08 | 01-JUL-00:22 | 14280.38 | 14280.38 | 8.29 | 111.21 |
August | 0.277405E+11 | 0.249664E+11 | 15867.08 | 01-AUG-01:02 | 14280.38 | 14280.38 | 8.25 | 111.21 |
September | 0.110942E+11 | 0.998480E+10 | 15867.08 | 01-SEP-00:03 | 14280.38 | 14280.38 | 7.96 | 111.21 |
October | 0.512523E+10 | 0.461270E+10 | 15867.08 | 01-OCT-10:08 | 14280.38 | 14280.38 | 8.11 | 111.21 |
November | 0.574674E+10 | 0.517207E+10 | 15867.08 | 01-NOV-04:01 | 14280.38 | 14280.38 | 8.55 | 111.21 |
December | 0.922900E+10 | 0.830610E+10 | 15867.08 | 01-DEC-07:05 | 14280.38 | 14280.38 | 8.43 | 111.21 |
Annual Sum or Average | 0.157104E+12 | 0.141393E+12 | ||||||
Minimum of Months | 0.512523E+10 | 0.461270E+10 | 15867.08 | 14280.38 | 14280.38 | 7.96 | 111.21 | |
Maximum of Months | 0.287737E+11 | 0.258963E+11 | 15867.08 | 14280.38 | 14280.38 | 9.25 | 111.21 |
Report: PumpReportMonthly
For: PLANT CIRC PUMP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.925800E+10 | 0.833220E+10 | 3456.54 | 01-JAN-00:01 | 3110.89 | 3110.89 | 21.35 | 14.44 |
February | 0.836206E+10 | 0.752586E+10 | 3456.54 | 01-FEB-00:03 | 3110.89 | 3110.89 | 23.20 | 14.44 |
March | 0.925800E+10 | 0.833220E+10 | 3456.54 | 01-MAR-00:10 | 3110.89 | 3110.89 | 26.87 | 14.44 |
April | 0.895935E+10 | 0.806342E+10 | 3456.54 | 01-APR-00:10 | 3110.89 | 3110.89 | 30.09 | 14.44 |
May | 0.925800E+10 | 0.833220E+10 | 3456.54 | 01-MAY-00:10 | 3110.89 | 3110.89 | 22.27 | 14.44 |
June | 0.895935E+10 | 0.806342E+10 | 3456.54 | 01-JUN-00:10 | 3110.89 | 3110.89 | 24.68 | 14.44 |
July | 0.925800E+10 | 0.833220E+10 | 3456.54 | 01-JUL-00:10 | 3110.89 | 3110.89 | 29.65 | 14.44 |
August | 0.925800E+10 | 0.833220E+10 | 3456.54 | 01-AUG-00:03 | 3110.89 | 3110.89 | 34.88 | 14.44 |
September | 0.895935E+10 | 0.806342E+10 | 3456.54 | 01-SEP-00:03 | 3110.89 | 3110.89 | 26.13 | 14.44 |
October | 0.925800E+10 | 0.833220E+10 | 3456.54 | 01-OCT-00:10 | 3110.89 | 3110.89 | 24.68 | 14.44 |
November | 0.895935E+10 | 0.806342E+10 | 3456.54 | 01-NOV-00:10 | 3110.89 | 3110.89 | 27.22 | 14.44 |
December | 0.925800E+10 | 0.833220E+10 | 3456.54 | 01-DEC-00:10 | 3110.89 | 3110.89 | 29.60 | 14.44 |
Annual Sum or Average | 0.109005E+12 | 0.981049E+11 | ||||||
Minimum of Months | 0.836206E+10 | 0.752586E+10 | 3456.54 | 3110.89 | 3110.89 | 21.35 | 14.44 | |
Maximum of Months | 0.925800E+10 | 0.833220E+10 | 3456.54 | 3110.89 | 3110.89 | 34.88 | 14.44 |
Report: PumpReportMonthly
For: SWHSYS1 PUMP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 11967951.72 | 3590385.52 | 5.96 | 01-JAN-06:01 | 1.79 | 1.79 | 56.19 | 0.44 |
February | 10809762.85 | 3242928.85 | 5.96 | 01-FEB-06:03 | 1.79 | 1.79 | 55.31 | 0.44 |
March | 11967951.72 | 3590385.52 | 5.96 | 01-MAR-06:01 | 1.79 | 1.79 | 55.30 | 0.44 |
April | 11581888.76 | 3474566.63 | 5.96 | 01-APR-05:03 | 1.79 | 1.79 | 54.78 | 0.44 |
May | 11967951.72 | 3590385.52 | 5.96 | 01-MAY-05:03 | 1.79 | 1.79 | 56.03 | 0.44 |
June | 11581888.76 | 3474566.63 | 5.96 | 01-JUN-05:03 | 1.79 | 1.79 | 55.92 | 0.44 |
July | 11967951.72 | 3590385.52 | 5.96 | 01-JUL-05:02 | 1.79 | 1.79 | 55.83 | 0.44 |
August | 11967951.72 | 3590385.52 | 5.96 | 01-AUG-05:03 | 1.79 | 1.79 | 55.55 | 0.44 |
September | 11581888.76 | 3474566.63 | 5.96 | 01-SEP-05:03 | 1.79 | 1.79 | 56.85 | 0.44 |
October | 11967951.72 | 3590385.52 | 5.96 | 01-OCT-05:10 | 1.79 | 1.79 | 55.34 | 0.44 |
November | 11581888.76 | 3474566.63 | 5.96 | 01-NOV-05:03 | 1.79 | 1.79 | 55.86 | 0.44 |
December | 11967951.72 | 3590385.52 | 5.96 | 01-DEC-06:01 | 1.79 | 1.79 | 55.37 | 0.44 |
Annual Sum or Average | 0.140913E+09 | 42273893.99 | ||||||
Minimum of Months | 10809762.85 | 3242928.85 | 5.96 | 1.79 | 1.79 | 54.78 | 0.44 | |
Maximum of Months | 11967951.72 | 3590385.52 | 5.96 | 1.79 | 1.79 | 56.85 | 0.44 |
Report: PumpReportMonthly
For: TOWERWATERSYS PUMP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.954399E+10 | 0.858959E+10 | 19584.34 | 10-JAN-19:20 | 17625.90 | 17625.90 | 21.21 | 65.24 |
February | 0.101673E+11 | 0.915058E+10 | 19584.34 | 14-FEB-20:40 | 17625.91 | 17625.91 | 21.21 | 65.24 |
March | 0.117332E+11 | 0.105599E+11 | 19584.37 | 28-MAR-13:20 | 17625.93 | 17625.93 | 21.21 | 65.24 |
April | 0.802290E+10 | 0.722061E+10 | 19619.81 | 13-APR-15:20 | 17657.83 | 17657.83 | 23.73 | 65.24 |
May | 0.200139E+11 | 0.180125E+11 | 39342.45 | 25-MAY-16:00 | 35408.20 | 35408.20 | 27.02 | 130.48 |
June | 0.347478E+11 | 0.312731E+11 | 39401.43 | 19-JUN-13:50 | 35461.29 | 35461.29 | 28.82 | 130.48 |
July | 0.442484E+11 | 0.398236E+11 | 39401.43 | 03-JUL-12:50 | 35461.29 | 35461.29 | 29.30 | 130.48 |
August | 0.405121E+11 | 0.364609E+11 | 39401.43 | 07-AUG-15:40 | 35461.29 | 35461.29 | 29.09 | 130.48 |
September | 0.144165E+11 | 0.129749E+11 | 39315.44 | 01-SEP-12:20 | 35383.90 | 35383.90 | 26.20 | 130.48 |
October | 0.640339E+10 | 0.576305E+10 | 39212.05 | 19-OCT-14:10 | 35290.84 | 35290.84 | 22.74 | 130.48 |
November | 0.709226E+10 | 0.638304E+10 | 19598.65 | 01-NOV-15:00 | 17638.78 | 17638.78 | 22.22 | 65.24 |
December | 0.113895E+11 | 0.102506E+11 | 19584.34 | 13-DEC-20:30 | 17625.91 | 17625.91 | 21.21 | 65.24 |
Annual Sum or Average | 0.218291E+12 | 0.196462E+12 | ||||||
Minimum of Months | 0.640339E+10 | 0.576305E+10 | 19584.34 | 17625.90 | 17625.90 | 21.21 | 65.24 | |
Maximum of Months | 0.442484E+11 | 0.398236E+11 | 39401.43 | 35461.29 | 35461.29 | 29.30 | 130.48 |
Report: CondLoopDemandReportMonthly
For: HEATSYS1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:01 | 38.86 | 38.86 | 398880.13 | 2932018.98 | 09-JAN-07:02 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 47.80 | 47.80 | 203518.46 | 2613590.94 | 14-FEB-07:03 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 24.35 | 24.35 | 86814.33 | 1890457.93 | 15-MAR-06:53 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.21 | 23.21 | 24930.35 | 1599543.07 | 10-APR-04:01 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 22.39 | 22.39 | 1758.70 | 417584.55 | 02-MAY-06:10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 26.35 | 26.35 | 88.70 | 103021.68 | 03-JUN-06:10 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 24.26 | 24.26 | 0.65 | 456.63 | 18-JUL-06:10 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 24.23 | 24.23 | 87.77 | 105376.01 | 19-AUG-06:13 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 24.28 | 24.28 | 2541.47 | 354752.20 | 06-SEP-06:10 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 21.54 | 21.54 | 25072.58 | 1604183.06 | 30-OCT-04:01 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 23.39 | 23.39 | 87538.56 | 2135164.95 | 27-NOV-05:11 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 24.86 | 24.86 | 295406.17 | 2575060.47 | 26-DEC-07:03 |
Annual Sum or Average | 0.00 | 93698.96 | ||||||
Minimum of Months | 0.00 | 0.00 | 21.54 | 21.54 | 0.65 | 456.63 | ||
Maximum of Months | 0.00 | 0.00 | 47.80 | 47.80 | 398880.13 | 2932018.98 |
Report: CondLoopDemandReportMonthly
For: COOLSYS1_SUPPLY
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 5165.06 | 28714.76 | 19-JAN-07:20 | 8.43 | 8.40 | 0.00 | 0.00 | 01-JAN-00:01 |
February | 6141.75 | 36135.83 | 13-FEB-11:00 | 8.45 | 8.41 | 0.00 | 0.00 | 01-FEB-00:03 |
March | 6570.06 | 62493.33 | 27-MAR-13:50 | 8.50 | 8.44 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 37643.50 | 1220854.84 | 13-APR-15:20 | 10.33 | 9.01 | 0.00 | 0.00 | 01-APR-00:10 |
May | 244402.27 | 1597391.89 | 26-MAY-11:00 | 10.52 | 7.09 | 18.01 | 147566.04 | 29-MAY-12:32 |
June | 519311.93 | 2421629.00 | 30-JUN-05:03 | 11.97 | 6.78 | 7.76 | 64350.57 | 04-JUN-19:33 |
July | 636516.18 | 5459282.62 | 05-JUL-11:00 | 18.78 | 13.09 | 33.17 | 110791.60 | 12-JUL-23:32 |
August | 505956.63 | 2299141.97 | 31-AUG-12:50 | 11.99 | 7.05 | 0.97 | 6771.05 | 21-AUG-23:32 |
September | 144765.73 | 1686810.95 | 07-SEP-14:10 | 10.74 | 8.52 | 27.77 | 131397.02 | 25-SEP-03:02 |
October | 28219.55 | 1374045.18 | 19-OCT-13:50 | 10.43 | 8.89 | 17.75 | 119052.27 | 01-OCT-10:08 |
November | 6975.89 | 473592.46 | 01-NOV-15:00 | 8.98 | 8.47 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 6208.27 | 50944.36 | 18-DEC-16:30 | 8.48 | 8.42 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 180430.30 | 8.86 | ||||||
Minimum of Months | 5165.06 | 28714.76 | 8.43 | 6.78 | 0.00 | 0.00 | ||
Maximum of Months | 636516.18 | 5459282.62 | 18.78 | 13.09 | 33.17 | 147566.04 |
Report: CondLoopDemandReportMonthly
For: COOLSYS1_DEMAND
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.85 | 615.25 | 31-JAN-19:00 | 7.93 | 8.40 | 0.00 | 0.00 | 01-JAN-00:01 |
February | 47.56 | 8425.01 | 08-FEB-14:10 | 9.56 | 8.41 | 0.00 | 0.00 | 01-FEB-00:03 |
March | 143.60 | 36114.73 | 31-MAR-10:45 | 13.39 | 8.43 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 20947.96 | 1417520.36 | 23-APR-14:42 | 13.29 | 7.54 | 0.00 | 0.00 | 01-APR-00:10 |
May | 191151.47 | 1902516.89 | 26-MAY-05:03 | 14.03 | 8.84 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 435288.69 | 3743330.09 | 30-JUN-05:03 | 14.91 | 6.86 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 552059.58 | 5623783.04 | 05-JUL-11:00 | 18.79 | 13.05 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 419190.91 | 2968928.29 | 09-AUG-03:02 | 15.35 | 7.78 | 0.00 | 0.00 | 01-AUG-00:03 |
September | 101076.21 | 1779786.75 | 19-SEP-05:03 | 13.85 | 9.05 | 0.00 | 0.00 | 01-SEP-00:03 |
October | 17205.91 | 977749.51 | 19-OCT-14:00 | 15.05 | 8.85 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 2101.11 | 309370.26 | 01-NOV-15:00 | 13.11 | 8.47 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 26.32 | 19988.86 | 18-DEC-16:30 | 13.50 | 8.42 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 146183.26 | 0.00 | ||||||
Minimum of Months | 0.85 | 615.25 | 7.93 | 6.86 | 0.00 | 0.00 | ||
Maximum of Months | 552059.58 | 5623783.04 | 18.79 | 13.05 | 0.00 | 0.00 |
Report: CondLoopDemandReportMonthly
For: SINGLE WATER PLANT LOOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 150028.33 | 296611.85 | 25-JAN-15:43 | 24.23 | 18.33 | 0.00 | 0.00 | 01-JAN-00:01 |
February | 293909.57 | 412781.96 | 22-FEB-16:00 | 26.52 | 18.33 | 0.00 | 0.00 | 01-FEB-00:03 |
March | 443705.32 | 594808.65 | 31-MAR-24:00 | 30.09 | 18.33 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 621097.98 | 1399092.15 | 23-APR-16:00 | 45.60 | 32.77 | 0.00 | 0.00 | 01-APR-00:10 |
May | 267419.46 | 904144.67 | 25-MAY-18:00 | 36.11 | 31.53 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 551963.69 | 1475360.49 | 29-JUN-16:00 | 47.05 | 38.88 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 815115.49 | 1467549.18 | 15-JUL-14:40 | 46.90 | 36.18 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 922643.26 | 1660578.45 | 08-AUG-16:00 | 50.54 | 37.04 | 0.00 | 0.00 | 01-AUG-00:03 |
September | 215981.92 | 734940.74 | 01-SEP-16:00 | 32.83 | 28.23 | 0.00 | 0.00 | 01-SEP-00:03 |
October | 323135.21 | 712787.94 | 19-OCT-15:00 | 32.40 | 25.43 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 446877.54 | 702506.31 | 01-NOV-15:00 | 32.20 | 22.70 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 569598.78 | 594128.28 | 14-DEC-13:03 | 30.08 | 18.33 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 469994.86 | 0.00 | ||||||
Minimum of Months | 150028.33 | 296611.85 | 24.23 | 18.33 | 0.00 | 0.00 | ||
Maximum of Months | 922643.26 | 1660578.45 | 50.54 | 38.88 | 0.00 | 0.00 |
Report: CondLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:01 | 57.23 | 57.23 | 18370.14 | 62713.90 | 31-JAN-12:40 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 56.14 | 56.14 | 18862.74 | 63343.77 | 24-FEB-12:10 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 55.85 | 55.85 | 19880.52 | 63281.93 | 01-MAR-12:30 |
April | 0.00 | 0.00 | 01-APR-00:10 | 55.61 | 55.61 | 18198.48 | 62040.70 | 03-APR-11:50 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 57.09 | 57.09 | 17892.96 | 59652.86 | 01-MAY-11:40 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 56.62 | 56.62 | 17285.79 | 56296.47 | 01-JUN-11:50 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 56.38 | 56.38 | 15251.48 | 52971.21 | 03-JUL-12:00 |
August | 0.00 | 0.00 | 01-AUG-00:03 | 56.15 | 56.15 | 16128.02 | 50944.40 | 01-AUG-11:20 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 57.36 | 57.36 | 15283.30 | 51365.12 | 29-SEP-11:30 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 56.24 | 56.24 | 15803.41 | 54021.31 | 31-OCT-12:00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 56.57 | 56.57 | 16858.26 | 57284.30 | 30-NOV-12:30 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 55.89 | 55.89 | 17192.01 | 60312.65 | 29-DEC-13:00 |
Annual Sum or Average | 0.00 | 17241.11 | ||||||
Minimum of Months | 0.00 | 0.00 | 55.61 | 55.61 | 15251.48 | 50944.40 | ||
Maximum of Months | 0.00 | 0.00 | 57.36 | 57.36 | 19880.52 | 63343.77 |
Report: CondLoopDemandReportMonthly
For: TOWERWATERSYS
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 529.80 | 29653.99 | 10-JAN-19:20 | 21.21 | 20.33 | 4609.19 | 149394.77 | 21-JAN-07:30 |
February | 564.29 | 29738.34 | 14-FEB-20:40 | 21.21 | 20.33 | 5910.30 | 150482.62 | 28-FEB-06:50 |
March | 540.88 | 30213.41 | 28-MAR-13:20 | 21.21 | 20.45 | 6743.09 | 149223.15 | 21-MAR-12:13 |
April | 20198.57 | 715828.54 | 13-APR-15:20 | 23.73 | 21.10 | 3156.16 | 151256.84 | 19-APR-08:00 |
May | 216932.59 | 3230060.16 | 25-MAY-16:00 | 27.02 | 23.69 | 666.71 | 111330.17 | 20-MAY-07:10 |
June | 682339.07 | 6291161.38 | 30-JUN-16:00 | 32.64 | 28.45 | 234.59 | 66338.02 | 02-JUN-15:50 |
July | 865647.56 | 7053767.69 | 05-JUL-11:00 | 34.03 | 28.47 | 175.40 | 37344.99 | 10-JUL-05:40 |
August | 598449.92 | 5482705.63 | 31-AUG-12:50 | 31.15 | 26.43 | 385.93 | 54421.40 | 05-AUG-20:50 |
September | 106153.65 | 2783541.01 | 01-SEP-12:20 | 26.20 | 22.68 | 764.54 | 109761.64 | 23-SEP-05:40 |
October | 16383.11 | 933971.54 | 19-OCT-14:30 | 24.53 | 21.10 | 2218.16 | 134227.99 | 30-OCT-06:20 |
November | 2273.39 | 306653.19 | 01-NOV-15:00 | 22.22 | 21.10 | 4058.89 | 148131.09 | 08-NOV-12:30 |
December | 611.96 | 29746.63 | 13-DEC-20:30 | 21.21 | 20.33 | 5739.91 | 150851.26 | 26-DEC-15:10 |
Annual Sum or Average | 211004.69 | 2872.89 | ||||||
Minimum of Months | 529.80 | 29653.99 | 21.21 | 20.33 | 175.40 | 37344.99 | ||
Maximum of Months | 865647.56 | 7053767.69 | 34.03 | 28.47 | 6743.09 | 151256.84 |
Report: ZoneTemperatureOscillationReportMonthly
For: BASEMENT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_MID
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_TOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: GROUNDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: DATACENTER_BOT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: DATACENTER_MID_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: DATACENTER_TOP_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: DATACENTER_BASEMENT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: VAV_BOT WITH REHEAT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.526824E+11 | 0.00 | 7632888.20 | 0.404957E+10 | 0.00 | 0.00 |
February | 0.189350E+11 | 0.00 | 34631270.58 | 0.462838E+10 | 0.00 | 0.00 |
March | 0.629037E+10 | 0.00 | 0.126098E+09 | 0.702940E+10 | 0.00 | 0.00 |
April | 0.176453E+10 | 0.00 | 0.469924E+10 | 0.892521E+10 | 0.00 | 0.00 |
May | 0.132595E+09 | 0.00 | 0.368903E+11 | 0.988380E+10 | 0.00 | 0.00 |
June | 1059873.33 | 0.00 | 0.880316E+11 | 0.124480E+11 | 0.00 | 0.00 |
July | 0.88 | 0.00 | 0.121069E+12 | 0.144340E+11 | 0.00 | 0.00 |
August | 1253577.46 | 0.00 | 0.946235E+11 | 0.142665E+11 | 0.00 | 0.00 |
September | 0.119634E+09 | 0.00 | 0.189854E+11 | 0.828192E+10 | 0.00 | 0.00 |
October | 0.111267E+10 | 0.00 | 0.321494E+10 | 0.691455E+10 | 0.00 | 0.00 |
November | 0.389626E+10 | 0.00 | 0.443683E+09 | 0.587275E+10 | 0.00 | 0.00 |
December | 0.270233E+11 | 0.00 | 29889424.99 | 0.479042E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.111959E+12 | 0.00 | 0.368156E+12 | 0.101525E+12 | 0.00 | 0.00 |
Minimum of Months | 0.88 | 0.00 | 7632888.20 | 0.404957E+10 | 0.00 | 0.00 |
Maximum of Months | 0.526824E+11 | 0.00 | 0.121069E+12 | 0.144340E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: VAV_MID WITH REHEAT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.885344E+12 | 0.00 | 1544876.73 | 0.498525E+11 | 0.00 | 0.00 |
February | 0.401112E+12 | 0.00 | 0.116206E+09 | 0.408363E+11 | 0.00 | 0.00 |
March | 0.185368E+12 | 0.00 | 0.152171E+09 | 0.458736E+11 | 0.00 | 0.00 |
April | 0.504873E+11 | 0.00 | 0.345965E+11 | 0.527474E+11 | 0.00 | 0.00 |
May | 0.349991E+10 | 0.00 | 0.333085E+12 | 0.818606E+11 | 0.00 | 0.00 |
June | 0.128131E+09 | 0.00 | 0.756544E+12 | 0.996686E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.969724E+12 | 0.109703E+12 | 0.00 | 0.00 |
August | 0.104968E+09 | 0.00 | 0.731377E+12 | 0.953079E+11 | 0.00 | 0.00 |
September | 0.473308E+10 | 0.00 | 0.165043E+12 | 0.641107E+11 | 0.00 | 0.00 |
October | 0.525469E+11 | 0.00 | 0.286663E+11 | 0.464184E+11 | 0.00 | 0.00 |
November | 0.182658E+12 | 0.00 | 0.299395E+10 | 0.390560E+11 | 0.00 | 0.00 |
December | 0.655671E+12 | 0.00 | 2385345.96 | 0.474005E+11 | 0.00 | 0.00 |
Annual Sum or Average | 0.242165E+13 | 0.00 | 0.302230E+13 | 0.772836E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 1544876.73 | 0.390560E+11 | 0.00 | 0.00 |
Maximum of Months | 0.885344E+12 | 0.00 | 0.969724E+12 | 0.109703E+12 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: VAV_TOP WITH REHEAT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.138524E+12 | 0.00 | 492153.63 | 0.597878E+10 | 0.00 | 0.00 |
February | 0.769080E+11 | 0.00 | 6264841.43 | 0.509526E+10 | 0.00 | 0.00 |
March | 0.429836E+11 | 0.00 | 27947230.70 | 0.492887E+10 | 0.00 | 0.00 |
April | 0.129598E+11 | 0.00 | 0.320805E+10 | 0.465357E+10 | 0.00 | 0.00 |
May | 0.109343E+10 | 0.00 | 0.354253E+11 | 0.732586E+10 | 0.00 | 0.00 |
June | 0.121144E+09 | 0.00 | 0.799198E+11 | 0.967919E+10 | 0.00 | 0.00 |
July | 1985407.39 | 0.00 | 0.103774E+12 | 0.107454E+11 | 0.00 | 0.00 |
August | 0.130473E+09 | 0.00 | 0.757541E+11 | 0.882940E+10 | 0.00 | 0.00 |
September | 0.181610E+10 | 0.00 | 0.155332E+11 | 0.527073E+10 | 0.00 | 0.00 |
October | 0.140614E+11 | 0.00 | 0.251675E+10 | 0.413026E+10 | 0.00 | 0.00 |
November | 0.423888E+11 | 0.00 | 0.261298E+09 | 0.478533E+10 | 0.00 | 0.00 |
December | 0.115537E+12 | 0.00 | 308613.59 | 0.576076E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.446526E+12 | 0.00 | 0.316427E+12 | 0.771834E+11 | 0.00 | 0.00 |
Minimum of Months | 1985407.39 | 0.00 | 308613.59 | 0.413026E+10 | 0.00 | 0.00 |
Maximum of Months | 0.138524E+12 | 0.00 | 0.103774E+12 | 0.107454E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: CAV_BAS
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.110074E+10 | 0.00 | 28581521.05 | 0.139205E+11 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 42141558.90 | 0.130681E+11 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 27748330.04 | 0.157664E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.723343E+09 | 0.147374E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.183804E+11 | 0.160316E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.415781E+11 | 0.157615E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.553168E+11 | 0.155023E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.449551E+11 | 0.171666E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.833262E+10 | 0.159590E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.112250E+10 | 0.157344E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.158960E+09 | 0.147632E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 56930004.98 | 0.143139E+11 | 0.00 | 0.00 |
Annual Sum or Average | 0.110074E+10 | 0.00 | 0.170723E+12 | 0.182725E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 27748330.04 | 0.130681E+11 | 0.00 | 0.00 |
Maximum of Months | 0.110074E+10 | 0.00 | 0.553168E+11 | 0.171666E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: AIRLOOP DATACENTER BASEMENT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.386860E+12 | 0.182794E+12 | 0.00 | 2.24 |
February | 0.00 | 0.00 | 0.625246E+12 | 0.215329E+12 | 0.00 | 1.90 |
March | 0.00 | 0.00 | 0.992838E+12 | 0.289366E+12 | 0.00 | 1.83 |
April | 0.00 | 0.00 | 0.125718E+13 | 0.330311E+12 | 0.00 | 1.36 |
May | 0.00 | 0.00 | 0.422602E+12 | 0.187569E+12 | 0.00 | 0.37 |
June | 0.00 | 0.00 | 0.719857E+12 | 0.248287E+12 | 0.00 | 0.05 |
July | 0.00 | 0.00 | 0.106488E+13 | 0.328015E+12 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.135945E+13 | 0.378961E+12 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.408485E+12 | 0.178078E+12 | 0.00 | 0.06 |
October | 0.00 | 0.00 | 0.712637E+12 | 0.237629E+12 | 0.00 | 0.44 |
November | 0.00 | 0.00 | 0.969566E+12 | 0.280204E+12 | 0.00 | 1.31 |
December | 0.00 | 0.00 | 0.128274E+13 | 0.337229E+12 | 0.00 | 2.06 |
Annual Sum or Average | 0.00 | 0.00 | 0.102024E+14 | 0.319377E+13 | 0.00 | 11.60 |
Minimum of Months | 0.00 | 0.00 | 0.386860E+12 | 0.178078E+12 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.135945E+13 | 0.378961E+12 | 0.00 | 2.24 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: AIRLOOP DATACENTER BOT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.254080E+10 | 0.216084E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.954532E+10 | 0.342842E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.179510E+11 | 0.513262E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.244860E+11 | 0.620953E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.746379E+10 | 0.314139E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.138908E+11 | 0.444864E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.210707E+11 | 0.606412E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.270072E+11 | 0.710240E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.686861E+10 | 0.290938E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.125492E+11 | 0.402012E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.174517E+11 | 0.494550E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.229220E+11 | 0.607434E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.183747E+12 | 0.556373E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.254080E+10 | 0.216084E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.270072E+11 | 0.710240E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: AIRLOOP DATACENTER MID
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.289191E+10 | 0.158055E+11 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.610234E+11 | 0.267874E+11 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.146902E+12 | 0.446149E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.218376E+12 | 0.567688E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.655543E+11 | 0.289529E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.128910E+12 | 0.418606E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.200150E+12 | 0.577931E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.254900E+12 | 0.673786E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.567162E+11 | 0.261666E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.101372E+12 | 0.351003E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.137611E+12 | 0.420339E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.179296E+12 | 0.510289E+11 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.155370E+13 | 0.494291E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.289191E+10 | 0.158055E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.254900E+12 | 0.673786E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: AIRLOOP DATACENTER TOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 88084169.31 | 0.155125E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.396249E+10 | 0.225150E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.124284E+11 | 0.406006E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.201950E+11 | 0.541975E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.596260E+10 | 0.280255E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.126225E+11 | 0.416319E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.199138E+11 | 0.579251E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.252907E+11 | 0.673514E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.487465E+10 | 0.248631E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.816916E+10 | 0.316557E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.112957E+11 | 0.376433E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.157000E+11 | 0.471584E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.140503E+12 | 0.469080E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 88084169.31 | 0.155125E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.252907E+11 | 0.673514E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: VAV_BOT WITH REHEAT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.404957E+10 | 7632888.20 | 0.526824E+11 | 0.810612E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.462838E+10 | 34631270.58 | 0.189350E+11 | 0.631067E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.702940E+10 | 0.126098E+09 | 0.629037E+10 | 0.500597E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.892521E+10 | 0.469924E+10 | 0.176453E+10 | 0.102177E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.988380E+10 | 0.368903E+11 | 0.132595E+09 | 0.145835E+10 | 0.262695E+09 | 0.00 | 0.00 | 0.00 |
June | 0.124480E+11 | 0.880316E+11 | 1059873.33 | 55922669.58 | 0.532700E+10 | 0.00 | 0.00 | 0.00 |
July | 0.144340E+11 | 0.121069E+12 | 0.88 | 86563631.38 | 0.649606E+10 | 0.00 | 0.00 | 0.00 |
August | 0.142665E+11 | 0.946235E+11 | 1253577.46 | 14524488.14 | 0.334597E+10 | 0.00 | 0.00 | 0.00 |
September | 0.828192E+10 | 0.189854E+11 | 0.119634E+09 | 0.108342E+10 | 53199045.45 | 0.00 | 0.00 | 0.00 |
October | 0.691455E+10 | 0.321494E+10 | 0.111267E+10 | 0.887477E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.587275E+10 | 0.443683E+09 | 0.389626E+10 | 0.308387E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.479042E+10 | 29889424.99 | 0.270233E+11 | 0.758986E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.101525E+12 | 0.368156E+12 | 0.111959E+12 | 0.322756E+12 | 0.154849E+11 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.404957E+10 | 7632888.20 | 0.88 | 14524488.14 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.144340E+11 | 0.121069E+12 | 0.526824E+11 | 0.810612E+11 | 0.649606E+10 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: VAV_MID WITH REHEAT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.498525E+11 | 1544876.73 | 0.885344E+12 | 0.808348E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.408363E+11 | 0.116206E+09 | 0.401112E+12 | 0.724164E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.458736E+11 | 0.154770E+09 | 0.185368E+12 | 0.694771E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.527474E+11 | 0.345965E+11 | 0.504873E+11 | 0.209480E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.818606E+11 | 0.333085E+12 | 0.349991E+10 | 0.255351E+11 | 0.284737E+10 | 0.00 | 0.00 | 0.00 |
June | 0.996686E+11 | 0.756544E+12 | 0.128131E+09 | 0.963070E+09 | 0.538488E+11 | 0.00 | 0.00 | 0.00 |
July | 0.109703E+12 | 0.969724E+12 | 0.00 | 0.105106E+10 | 0.639390E+11 | 0.00 | 0.00 | 0.00 |
August | 0.953079E+11 | 0.731377E+12 | 0.104968E+09 | 0.908177E+09 | 0.324927E+11 | 0.00 | 0.00 | 0.00 |
September | 0.641107E+11 | 0.165043E+12 | 0.473308E+10 | 0.222667E+11 | 0.685976E+09 | 0.00 | 0.00 | 0.00 |
October | 0.464184E+11 | 0.286663E+11 | 0.525469E+11 | 0.179888E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.390560E+11 | 0.299395E+10 | 0.182658E+12 | 0.462455E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.474005E+11 | 2385345.96 | 0.655671E+12 | 0.845304E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.772836E+12 | 0.302231E+13 | 0.242165E+13 | 0.397513E+13 | 0.153814E+12 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.390560E+11 | 1544876.73 | 0.00 | 0.908177E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.109703E+12 | 0.969724E+12 | 0.885344E+12 | 0.845304E+12 | 0.639390E+11 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: VAV_TOP WITH REHEAT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.597878E+10 | 492153.63 | 0.138524E+12 | 0.779392E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.509526E+10 | 6264841.43 | 0.769080E+11 | 0.700074E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.492887E+10 | 27947230.70 | 0.429836E+11 | 0.715544E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.465357E+10 | 0.320805E+10 | 0.129598E+11 | 0.263411E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.732586E+10 | 0.354253E+11 | 0.109343E+10 | 0.374532E+10 | 0.221030E+09 | 0.00 | 0.00 | 0.00 |
June | 0.967919E+10 | 0.799198E+11 | 0.121144E+09 | 97775293.71 | 0.500637E+10 | 0.00 | 0.00 | 0.00 |
July | 0.107454E+11 | 0.103774E+12 | 1985407.39 | 50717018.83 | 0.558461E+10 | 0.00 | 0.00 | 0.00 |
August | 0.882940E+10 | 0.757541E+11 | 0.130473E+09 | 0.119283E+09 | 0.259485E+10 | 0.00 | 0.00 | 0.00 |
September | 0.527073E+10 | 0.155332E+11 | 0.181610E+10 | 0.386265E+10 | 28127140.93 | 0.00 | 0.00 | 0.00 |
October | 0.413026E+10 | 0.251675E+10 | 0.140614E+11 | 0.243948E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.478533E+10 | 0.261298E+09 | 0.423888E+11 | 0.499361E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.576076E+10 | 308613.59 | 0.115537E+12 | 0.807265E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.771834E+11 | 0.316427E+12 | 0.446526E+12 | 0.408775E+12 | 0.134350E+11 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.413026E+10 | 308613.59 | 1985407.39 | 50717018.83 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.107454E+11 | 0.103774E+12 | 0.138524E+12 | 0.807265E+11 | 0.558461E+10 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: CAV_BAS
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.139205E+11 | 28581521.05 | 0.110074E+10 | 0.252333E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.130681E+11 | 42141558.90 | 0.00 | 0.133795E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.157664E+11 | 27748330.04 | 0.00 | 0.585887E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.147374E+11 | 0.723343E+09 | 0.00 | 0.503313E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.160316E+11 | 0.183804E+11 | 0.00 | 0.524049E+09 | 57842377.65 | 0.00 | 0.00 | 0.00 |
June | 0.157615E+11 | 0.415781E+11 | 0.00 | 0.138320E+09 | 0.206942E+10 | 0.00 | 0.00 | 0.00 |
July | 0.155023E+11 | 0.553168E+11 | 0.00 | 0.193769E+09 | 0.230654E+10 | 0.00 | 0.00 | 0.00 |
August | 0.171666E+11 | 0.449551E+11 | 0.00 | 0.112072E+09 | 0.128822E+10 | 0.00 | 0.00 | 0.00 |
September | 0.159590E+11 | 0.833262E+10 | 0.00 | 0.178334E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.157344E+11 | 0.112250E+10 | 0.00 | 0.229560E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.147632E+11 | 0.158960E+09 | 0.00 | 0.157427E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.143139E+11 | 56930004.98 | 0.00 | 0.140855E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.182725E+12 | 0.170723E+12 | 0.110074E+10 | 0.620107E+11 | 0.572202E+10 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.130681E+11 | 27748330.04 | 0.00 | 0.112072E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.171666E+11 | 0.553168E+11 | 0.110074E+10 | 0.252333E+11 | 0.230654E+10 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: AIRLOOP DATACENTER BASEMENT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.984279E+11 | 0.308505E+12 | 0.00 | 0.00 | 0.00 | 0.598381E+10 | 0.00 | 0.00 |
February | 0.889026E+11 | 0.503923E+12 | 0.00 | 0.00 | 0.00 | 0.507994E+10 | 0.00 | 0.00 |
March | 0.984279E+11 | 0.806810E+12 | 0.00 | 0.00 | 0.00 | 0.488844E+10 | 0.00 | 0.00 |
April | 0.952528E+11 | 0.102578E+13 | 0.00 | 0.00 | 0.00 | 0.364031E+10 | 0.00 | 0.00 |
May | 0.984279E+11 | 0.334445E+12 | 0.00 | 0.00 | 0.00 | 0.980032E+09 | 0.00 | 0.00 |
June | 0.952528E+11 | 0.566959E+12 | 0.00 | 0.00 | 0.00 | 0.135893E+09 | 0.00 | 0.00 |
July | 0.984279E+11 | 0.835293E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.984279E+11 | 0.107892E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.952528E+11 | 0.325809E+12 | 0.00 | 0.00 | 0.00 | 0.148223E+09 | 0.00 | 0.00 |
October | 0.984279E+11 | 0.574629E+12 | 0.00 | 0.00 | 0.00 | 0.118740E+10 | 0.00 | 0.00 |
November | 0.952528E+11 | 0.788135E+12 | 0.00 | 0.00 | 0.00 | 0.350466E+10 | 0.00 | 0.00 |
December | 0.984279E+11 | 0.104947E+13 | 0.00 | 0.00 | 0.00 | 0.550285E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.115891E+13 | 0.819868E+13 | 0.00 | 0.00 | 0.00 | 0.310516E+11 | 0.00 | 0.00 |
Minimum of Months | 0.889026E+11 | 0.308505E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.984279E+11 | 0.107892E+13 | 0.00 | 0.00 | 0.00 | 0.598381E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: AIRLOOP DATACENTER BOT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.157337E+10 | 0.195333E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.142110E+10 | 0.753800E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.157337E+10 | 0.143917E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.152261E+10 | 0.197991E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.157337E+10 | 0.589576E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.152261E+10 | 0.109648E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.157337E+10 | 0.165799E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.157337E+10 | 0.214782E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.152261E+10 | 0.548185E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.157337E+10 | 0.101025E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.152261E+10 | 0.140289E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.157337E+10 | 0.184210E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.185251E+11 | 0.146635E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.142110E+10 | 0.195333E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.157337E+10 | 0.214782E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: AIRLOOP DATACENTER MID
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.150825E+11 | 0.216893E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.136229E+11 | 0.478589E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.150825E+11 | 0.117370E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.145960E+11 | 0.176203E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.150825E+11 | 0.516839E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.145960E+11 | 0.101645E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.150825E+11 | 0.157439E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.150825E+11 | 0.202604E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.145960E+11 | 0.451456E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.150825E+11 | 0.813543E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.145960E+11 | 0.110173E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.150825E+11 | 0.143349E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.177584E+12 | 0.123700E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.136229E+11 | 0.216893E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.150825E+11 | 0.202604E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: AIRLOOP DATACENTER TOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.152966E+10 | 66495916.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.138163E+10 | 0.309261E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.152966E+10 | 0.989801E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.148031E+10 | 0.162555E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.152966E+10 | 0.468971E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.148031E+10 | 0.993960E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.152966E+10 | 0.156509E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.152966E+10 | 0.200852E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.148031E+10 | 0.386866E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.152966E+10 | 0.653324E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.148031E+10 | 0.901172E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.152966E+10 | 0.125139E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.180105E+11 | 0.111606E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.138163E+10 | 66495916.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.152966E+10 | 0.200852E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: VAV_BOT WITH REHEAT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.404957E+10 | 0.526824E+11 | 7632888.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.462838E+10 | 0.189350E+11 | 34631270.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.702940E+10 | 0.629037E+10 | 0.126098E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.892521E+10 | 0.176453E+10 | 0.469924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.988380E+10 | 0.132595E+09 | 0.368903E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.124480E+11 | 1059873.33 | 0.880316E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.144340E+11 | 0.88 | 0.121069E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.142665E+11 | 1253577.46 | 0.946235E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.828192E+10 | 0.119634E+09 | 0.189854E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.691455E+10 | 0.111267E+10 | 0.321494E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.587275E+10 | 0.389626E+10 | 0.443683E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.479042E+10 | 0.270233E+11 | 29889424.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.101525E+12 | 0.111959E+12 | 0.368156E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.404957E+10 | 0.88 | 7632888.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.144340E+11 | 0.526824E+11 | 0.121069E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: VAV_MID WITH REHEAT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.498525E+11 | 0.885344E+12 | 1544876.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.408363E+11 | 0.401112E+12 | 0.116206E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.458736E+11 | 0.185368E+12 | 0.152171E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.527474E+11 | 0.504873E+11 | 0.345965E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.818606E+11 | 0.349991E+10 | 0.333085E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.996686E+11 | 0.128131E+09 | 0.756544E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.109703E+12 | 0.00 | 0.969724E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.953079E+11 | 0.104968E+09 | 0.731377E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.641107E+11 | 0.473308E+10 | 0.165043E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.464184E+11 | 0.525469E+11 | 0.286663E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.390560E+11 | 0.182658E+12 | 0.299395E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.474005E+11 | 0.655671E+12 | 2385345.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.772836E+12 | 0.242165E+13 | 0.302230E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.390560E+11 | 0.00 | 1544876.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.109703E+12 | 0.885344E+12 | 0.969724E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: VAV_TOP WITH REHEAT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.597878E+10 | 0.138524E+12 | 492153.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.509526E+10 | 0.769080E+11 | 6264841.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.492887E+10 | 0.429836E+11 | 27947230.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.465357E+10 | 0.129598E+11 | 0.320805E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.732586E+10 | 0.109343E+10 | 0.354253E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.967919E+10 | 0.121144E+09 | 0.799198E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.107454E+11 | 1985407.39 | 0.103774E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.882940E+10 | 0.130473E+09 | 0.757541E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.527073E+10 | 0.181610E+10 | 0.155332E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.413026E+10 | 0.140614E+11 | 0.251675E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.478533E+10 | 0.423888E+11 | 0.261298E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.576076E+10 | 0.115537E+12 | 308613.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.771834E+11 | 0.446526E+12 | 0.316427E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.413026E+10 | 1985407.39 | 308613.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.107454E+11 | 0.138524E+12 | 0.103774E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: CAV_BAS
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.139205E+11 | 0.110074E+10 | 28581521.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.130681E+11 | 0.00 | 42141558.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.157664E+11 | 0.00 | 27748330.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.147374E+11 | 0.00 | 0.723343E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.160316E+11 | 0.00 | 0.183804E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.157615E+11 | 0.00 | 0.415781E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.155023E+11 | 0.00 | 0.553168E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.171666E+11 | 0.00 | 0.449551E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.159590E+11 | 0.00 | 0.833262E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.157344E+11 | 0.00 | 0.112250E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.147632E+11 | 0.00 | 0.158960E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.143139E+11 | 0.00 | 56930004.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.182725E+12 | 0.110074E+10 | 0.170723E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.130681E+11 | 0.00 | 27748330.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.171666E+11 | 0.110074E+10 | 0.553168E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: AIRLOOP DATACENTER BASEMENT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.984279E+11 | 0.00 | 0.386860E+12 | 0.00 | 0.783549E+11 | 0.00 | 0.00 | 0.00 | 0.601074E+10 | 0.00 | 0.00 | 0.00 |
February | 0.889026E+11 | 0.00 | 0.625246E+12 | 0.00 | 0.121323E+12 | 0.00 | 0.00 | 0.00 | 0.510281E+10 | 0.00 | 0.00 | 0.00 |
March | 0.984279E+11 | 0.00 | 0.992838E+12 | 0.00 | 0.186028E+12 | 0.00 | 0.00 | 0.00 | 0.491044E+10 | 0.00 | 0.00 | 0.00 |
April | 0.952528E+11 | 0.00 | 0.125718E+13 | 0.00 | 0.231402E+12 | 0.00 | 0.00 | 0.00 | 0.365670E+10 | 0.00 | 0.00 | 0.00 |
May | 0.984279E+11 | 0.00 | 0.422602E+12 | 0.00 | 0.881570E+11 | 0.00 | 0.00 | 0.00 | 0.984444E+09 | 0.00 | 0.00 | 0.00 |
June | 0.952528E+11 | 0.00 | 0.719857E+12 | 0.00 | 0.152898E+12 | 0.00 | 0.00 | 0.00 | 0.136505E+09 | 0.00 | 0.00 | 0.00 |
July | 0.984279E+11 | 0.00 | 0.106488E+13 | 0.00 | 0.229587E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.984279E+11 | 0.00 | 0.135945E+13 | 0.00 | 0.280533E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.952528E+11 | 0.00 | 0.408485E+12 | 0.00 | 0.826760E+11 | 0.00 | 0.00 | 0.00 | 0.148890E+09 | 0.00 | 0.00 | 0.00 |
October | 0.984279E+11 | 0.00 | 0.712637E+12 | 0.00 | 0.138008E+12 | 0.00 | 0.00 | 0.00 | 0.119275E+10 | 0.00 | 0.00 | 0.00 |
November | 0.952528E+11 | 0.00 | 0.969566E+12 | 0.00 | 0.181431E+12 | 0.00 | 0.00 | 0.00 | 0.352043E+10 | 0.00 | 0.00 | 0.00 |
December | 0.984279E+11 | 0.00 | 0.128274E+13 | 0.00 | 0.233274E+12 | 0.00 | 0.00 | 0.00 | 0.552762E+10 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.115891E+13 | 0.00 | 0.102024E+14 | 0.00 | 0.200367E+13 | 0.00 | 0.00 | 0.00 | 0.311913E+11 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.889026E+11 | 0.00 | 0.386860E+12 | 0.00 | 0.783549E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.984279E+11 | 0.00 | 0.135945E+13 | 0.00 | 0.280533E+12 | 0.00 | 0.00 | 0.00 | 0.601074E+10 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: AIRLOOP DATACENTER BOT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.157337E+10 | 0.00 | 0.254080E+10 | 0.00 | 0.587470E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.142110E+10 | 0.00 | 0.954532E+10 | 0.00 | 0.200731E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.157337E+10 | 0.00 | 0.179510E+11 | 0.00 | 0.355926E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.152261E+10 | 0.00 | 0.244860E+11 | 0.00 | 0.468692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.157337E+10 | 0.00 | 0.746379E+10 | 0.00 | 0.156803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.152261E+10 | 0.00 | 0.138908E+11 | 0.00 | 0.292603E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.157337E+10 | 0.00 | 0.210707E+11 | 0.00 | 0.449075E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.157337E+10 | 0.00 | 0.270072E+11 | 0.00 | 0.552903E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.152261E+10 | 0.00 | 0.686861E+10 | 0.00 | 0.138677E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.157337E+10 | 0.00 | 0.125492E+11 | 0.00 | 0.244676E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.152261E+10 | 0.00 | 0.174517E+11 | 0.00 | 0.342289E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.157337E+10 | 0.00 | 0.229220E+11 | 0.00 | 0.450098E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.185251E+11 | 0.00 | 0.183747E+12 | 0.00 | 0.371122E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.142110E+10 | 0.00 | 0.254080E+10 | 0.00 | 0.587470E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.157337E+10 | 0.00 | 0.270072E+11 | 0.00 | 0.552903E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: AIRLOOP DATACENTER MID
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.150825E+11 | 0.00 | 0.289191E+10 | 0.00 | 0.722976E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.136229E+11 | 0.00 | 0.610234E+11 | 0.00 | 0.131645E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.150825E+11 | 0.00 | 0.146902E+12 | 0.00 | 0.295324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.145960E+11 | 0.00 | 0.218376E+12 | 0.00 | 0.421728E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.150825E+11 | 0.00 | 0.655543E+11 | 0.00 | 0.138704E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.145960E+11 | 0.00 | 0.128910E+12 | 0.00 | 0.272647E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.150825E+11 | 0.00 | 0.200150E+12 | 0.00 | 0.427105E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.150825E+11 | 0.00 | 0.254900E+12 | 0.00 | 0.522961E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.145960E+11 | 0.00 | 0.567162E+11 | 0.00 | 0.115706E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.150825E+11 | 0.00 | 0.101372E+12 | 0.00 | 0.200178E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.145960E+11 | 0.00 | 0.137611E+12 | 0.00 | 0.274379E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.150825E+11 | 0.00 | 0.179296E+12 | 0.00 | 0.359464E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.177584E+12 | 0.00 | 0.155370E+13 | 0.00 | 0.316707E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.136229E+11 | 0.00 | 0.289191E+10 | 0.00 | 0.722976E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.150825E+11 | 0.00 | 0.254900E+12 | 0.00 | 0.522961E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: AIRLOOP DATACENTER TOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.152966E+10 | 0.00 | 88084169.31 | 0.00 | 21588252.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.138163E+10 | 0.00 | 0.396249E+10 | 0.00 | 0.869873E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.152966E+10 | 0.00 | 0.124284E+11 | 0.00 | 0.253040E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.148031E+10 | 0.00 | 0.201950E+11 | 0.00 | 0.393943E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.152966E+10 | 0.00 | 0.596260E+10 | 0.00 | 0.127289E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.148031E+10 | 0.00 | 0.126225E+11 | 0.00 | 0.268288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.152966E+10 | 0.00 | 0.199138E+11 | 0.00 | 0.426285E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.152966E+10 | 0.00 | 0.252907E+11 | 0.00 | 0.520548E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.148031E+10 | 0.00 | 0.487465E+10 | 0.00 | 0.100600E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.152966E+10 | 0.00 | 0.816916E+10 | 0.00 | 0.163592E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.148031E+10 | 0.00 | 0.112957E+11 | 0.00 | 0.228402E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.152966E+10 | 0.00 | 0.157000E+11 | 0.00 | 0.318618E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.180105E+11 | 0.00 | 0.140503E+12 | 0.00 | 0.288975E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.138163E+10 | 0.00 | 88084169.31 | 0.00 | 21588252.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.152966E+10 | 0.00 | 0.252907E+11 | 0.00 | 0.520548E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: BASEMENT
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.207472E+11 | 0.00 | 0.00 | 52561884.30 | 0.00 | 0.00 | 0.381071E+11 | 0.00 | 0.32 |
February | 0.515178E+10 | 0.00 | 0.00 | 85699425.01 | 0.00 | 0.00 | 0.521142E+11 | 0.00 | 0.37 |
March | 0.232885E+09 | 0.00 | 0.00 | 0.125918E+09 | 0.00 | 0.00 | 0.704477E+11 | 0.00 | 0.44 |
April | 0.170141E+09 | 0.00 | 0.00 | 0.116668E+09 | 0.00 | 0.00 | 0.697122E+11 | 0.00 | 0.74 |
May | 0.138493E+09 | 6363957.97 | 0.00 | 0.114614E+09 | 0.00 | 0.00 | 0.594857E+11 | 0.00 | 1.13 |
June | 77919788.72 | 0.289413E+10 | 0.00 | 98436101.56 | 34965128.14 | 0.00 | 0.414749E+11 | 0.00 | 1.39 |
July | 0.112124E+09 | 0.464358E+10 | 0.00 | 94337629.17 | 84526668.10 | 0.00 | 0.308195E+11 | 0.00 | 1.22 |
August | 0.117327E+09 | 0.299103E+10 | 0.00 | 0.120653E+09 | 1316829.33 | 0.00 | 0.492596E+11 | 0.00 | 1.53 |
September | 0.250304E+09 | 0.00 | 0.00 | 0.128017E+09 | 0.00 | 0.00 | 0.719746E+11 | 0.00 | 1.23 |
October | 0.286908E+09 | 0.00 | 0.00 | 0.128627E+09 | 0.00 | 0.00 | 0.780953E+11 | 0.00 | 0.79 |
November | 0.246526E+09 | 0.00 | 0.00 | 0.125378E+09 | 0.00 | 0.00 | 0.722675E+11 | 0.00 | 0.56 |
December | 0.847086E+10 | 0.00 | 0.00 | 95870818.24 | 0.00 | 0.00 | 0.574322E+11 | 0.00 | 0.34 |
Annual Sum or Average | 0.360025E+11 | 0.105351E+11 | 0.00 | 0.128678E+10 | 0.120809E+09 | 0.00 | 0.691190E+12 | 0.00 | 0.84 |
Minimum of Months | 77919788.72 | 0.00 | 0.00 | 52561884.30 | 0.00 | 0.00 | 0.308195E+11 | 0.00 | 0.32 |
Maximum of Months | 0.207472E+11 | 0.464358E+10 | 0.00 | 0.128627E+09 | 84526668.10 | 0.00 | 0.780953E+11 | 0.00 | 1.53 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.266699E+11 | 0.00 | 0.00 | 24625181.79 | 0.00 | 4397713.66 | 0.224142E+11 | 0.00 | 0.38 |
February | 0.984518E+10 | 0.00 | 0.00 | 50221454.95 | 0.00 | 0.00 | 0.322131E+11 | 0.00 | 0.41 |
March | 0.295480E+10 | 0.00 | 0.00 | 96450973.64 | 0.00 | 0.00 | 0.512021E+11 | 0.00 | 0.47 |
April | 0.383140E+10 | 0.00 | 0.00 | 0.103769E+09 | 35925910.45 | 0.00 | 0.573723E+11 | 0.00 | 0.67 |
May | 0.514732E+10 | 0.137194E+09 | 0.00 | 91950657.23 | 0.00 | 0.00 | 0.435948E+11 | 0.00 | 0.86 |
June | 0.422485E+10 | 0.473398E+10 | 0.00 | 78158914.21 | 0.496423E+09 | 0.00 | 0.291971E+11 | 0.00 | 1.07 |
July | 0.794996E+10 | 0.716674E+10 | 0.00 | 58690638.24 | 0.185490E+10 | 0.00 | 0.191585E+11 | 0.00 | 1.07 |
August | 0.102466E+11 | 0.474700E+10 | 0.00 | 79784581.72 | 88589601.15 | 0.00 | 0.319549E+11 | 0.00 | 1.27 |
September | 0.452009E+10 | 91876037.81 | 0.00 | 87715620.05 | 0.00 | 0.00 | 0.487843E+11 | 0.00 | 0.87 |
October | 0.330557E+10 | 0.00 | 0.00 | 90964880.60 | 0.00 | 0.00 | 0.533985E+11 | 0.00 | 0.59 |
November | 0.198714E+10 | 0.00 | 0.00 | 82590780.14 | 0.00 | 0.00 | 0.471382E+11 | 0.00 | 0.48 |
December | 0.789450E+10 | 0.00 | 0.00 | 54422062.69 | 0.00 | 0.00 | 0.406091E+11 | 0.00 | 0.40 |
Annual Sum or Average | 0.885772E+11 | 0.168768E+11 | 0.00 | 0.899345E+09 | 0.247583E+10 | 4397713.66 | 0.477037E+12 | 0.00 | 0.71 |
Minimum of Months | 0.198714E+10 | 0.00 | 0.00 | 24625181.79 | 0.00 | 0.00 | 0.191585E+11 | 0.00 | 0.38 |
Maximum of Months | 0.266699E+11 | 0.716674E+10 | 0.00 | 0.103769E+09 | 0.185490E+10 | 4397713.66 | 0.573723E+11 | 0.00 | 1.27 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_MID
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.425085E+12 | 0.00 | 0.00 | 5849125.10 | 0.00 | 0.179234E+11 | 0.724954E+10 | 0.00 | 0.37 |
February | 0.281461E+12 | 0.00 | 0.00 | 31924366.27 | 0.00 | 0.245332E+10 | 0.324808E+11 | 0.00 | 0.38 |
March | 0.197113E+12 | 0.00 | 0.00 | 0.214425E+09 | 0.00 | 0.349399E+09 | 0.140117E+12 | 0.00 | 0.41 |
April | 0.860207E+11 | 0.00 | 0.00 | 0.431341E+09 | 0.820441E+09 | 0.00 | 0.290100E+12 | 0.00 | 0.49 |
May | 0.396593E+11 | 0.138487E+10 | 0.00 | 0.707778E+09 | 0.00 | 0.00 | 0.344340E+12 | 0.00 | 0.72 |
June | 0.207800E+11 | 0.401364E+11 | 0.00 | 0.620538E+09 | 0.372490E+10 | 0.00 | 0.233494E+12 | 0.00 | 0.87 |
July | 0.290639E+11 | 0.594655E+11 | 0.00 | 0.502891E+09 | 0.654257E+10 | 0.00 | 0.157943E+12 | 0.00 | 0.80 |
August | 0.287921E+11 | 0.342524E+11 | 0.00 | 0.612410E+09 | 0.608900E+09 | 0.00 | 0.243481E+12 | 0.00 | 0.90 |
September | 0.441194E+11 | 0.974926E+09 | 0.00 | 0.607772E+09 | 0.00 | 0.00 | 0.364867E+12 | 0.00 | 0.70 |
October | 0.994774E+11 | 0.00 | 0.00 | 0.394628E+09 | 0.00 | 0.00 | 0.272702E+12 | 0.00 | 0.46 |
November | 0.165902E+12 | 0.00 | 0.00 | 0.163266E+09 | 0.00 | 0.112587E+10 | 0.124952E+12 | 0.00 | 0.39 |
December | 0.345051E+12 | 0.00 | 0.00 | 10337306.44 | 0.00 | 0.110737E+11 | 0.108267E+11 | 0.00 | 0.37 |
Annual Sum or Average | 0.176252E+13 | 0.136214E+12 | 0.00 | 0.430316E+10 | 0.116968E+11 | 0.329257E+11 | 0.222255E+13 | 0.00 | 0.57 |
Minimum of Months | 0.207800E+11 | 0.00 | 0.00 | 5849125.10 | 0.00 | 0.00 | 0.724954E+10 | 0.00 | 0.37 |
Maximum of Months | 0.425085E+12 | 0.594655E+11 | 0.00 | 0.707778E+09 | 0.654257E+10 | 0.179234E+11 | 0.364867E+12 | 0.00 | 0.90 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_TOP
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.266905E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110721E+11 | 0.00 | 0.00 | 0.34 |
February | 0.201118E+11 | 0.00 | 0.00 | 91607.99 | 0.00 | 0.537295E+10 | 0.242555E+09 | 0.00 | 0.35 |
March | 0.219519E+11 | 0.00 | 0.00 | 2177302.64 | 0.00 | 0.171681E+10 | 0.226938E+10 | 0.00 | 0.38 |
April | 0.145407E+11 | 0.00 | 0.00 | 16931638.78 | 92762463.72 | 0.358580E+09 | 0.141015E+11 | 0.00 | 0.44 |
May | 0.751387E+10 | 0.142900E+09 | 0.00 | 53289196.47 | 0.00 | 1776872.01 | 0.250723E+11 | 0.00 | 0.68 |
June | 0.316602E+10 | 0.404147E+10 | 0.00 | 52988078.11 | 0.504438E+09 | 0.00 | 0.205937E+11 | 0.00 | 0.86 |
July | 0.284276E+10 | 0.620222E+10 | 0.00 | 45032505.79 | 0.817317E+09 | 0.00 | 0.143377E+11 | 0.00 | 0.81 |
August | 0.348296E+10 | 0.366965E+10 | 0.00 | 51317649.28 | 29782075.10 | 0.00 | 0.204881E+11 | 0.00 | 0.87 |
September | 0.908121E+10 | 75627487.29 | 0.00 | 36959201.11 | 0.00 | 0.00 | 0.234965E+11 | 0.00 | 0.61 |
October | 0.168660E+11 | 0.00 | 0.00 | 10669831.46 | 0.00 | 0.350079E+09 | 0.921573E+10 | 0.00 | 0.41 |
November | 0.180986E+11 | 0.00 | 0.00 | 1358888.83 | 292338.35 | 0.182972E+10 | 0.188901E+10 | 0.00 | 0.37 |
December | 0.200173E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.978423E+10 | 0.00 | 0.00 | 0.34 |
Annual Sum or Average | 0.164364E+12 | 0.141319E+11 | 0.00 | 0.270816E+09 | 0.144459E+10 | 0.304863E+11 | 0.131706E+12 | 0.00 | 0.54 |
Minimum of Months | 0.284276E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.34 |
Maximum of Months | 0.266905E+11 | 0.620222E+10 | 0.00 | 53289196.47 | 0.817317E+09 | 0.110721E+11 | 0.250723E+11 | 0.00 | 0.87 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.152733E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.536191E+10 | 0.00 | 0.00 | 0.41 |
February | 0.295872E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188690E+10 | 0.00 | 0.00 | 0.38 |
March | 0.448070E+10 | 0.00 | 0.00 | 605917.03 | 0.00 | 0.252467E+09 | 0.601706E+09 | 0.00 | 0.39 |
April | 0.292937E+10 | 0.00 | 0.00 | 3708248.82 | 5337857.20 | 0.00 | 0.306016E+10 | 0.00 | 0.55 |
May | 0.139727E+10 | 24988885.32 | 0.00 | 9696692.98 | 0.00 | 0.00 | 0.476994E+10 | 0.00 | 0.94 |
June | 0.781659E+09 | 0.872958E+09 | 0.00 | 10413473.95 | 72744077.86 | 0.00 | 0.402836E+10 | 0.00 | 1.33 |
July | 0.128369E+10 | 0.124131E+10 | 0.00 | 8146070.07 | 0.275653E+09 | 0.00 | 0.273270E+10 | 0.00 | 1.35 |
August | 0.171488E+10 | 0.753444E+09 | 0.00 | 9037664.71 | 13200371.81 | 0.00 | 0.372797E+10 | 0.00 | 1.40 |
September | 0.197289E+10 | 13995995.45 | 0.00 | 6101934.90 | 0.00 | 0.00 | 0.406420E+10 | 0.00 | 0.82 |
October | 0.328288E+10 | 0.00 | 0.00 | 2575763.60 | 0.00 | 0.00 | 0.217775E+10 | 0.00 | 0.47 |
November | 0.381171E+10 | 0.00 | 0.00 | 473459.72 | 0.00 | 0.152952E+09 | 0.645437E+09 | 0.00 | 0.38 |
December | 0.291867E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.259301E+10 | 0.00 | 0.00 | 0.36 |
Annual Sum or Average | 0.290598E+11 | 0.290669E+10 | 0.00 | 50759225.79 | 0.366935E+09 | 0.102472E+11 | 0.258082E+11 | 0.00 | 0.73 |
Minimum of Months | 0.781659E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
Maximum of Months | 0.448070E+10 | 0.124131E+10 | 0.00 | 10413473.95 | 0.275653E+09 | 0.536191E+10 | 0.476994E+10 | 0.00 | 1.40 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.319429E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.590420E+10 | 0.00 | 0.00 | 0.84 |
February | 0.432935E+10 | 0.00 | 0.00 | 168598.05 | 0.00 | 0.200375E+10 | 0.124613E+09 | 0.00 | 0.78 |
March | 0.546019E+10 | 0.00 | 0.00 | 2151349.31 | 0.00 | 0.471415E+09 | 0.137421E+10 | 0.00 | 0.82 |
April | 0.428520E+10 | 0.00 | 0.00 | 5772730.78 | 7112034.58 | 3615234.14 | 0.402882E+10 | 0.00 | 1.14 |
May | 0.257499E+10 | 17736579.10 | 0.00 | 9022950.91 | 0.00 | 0.00 | 0.464481E+10 | 0.00 | 1.61 |
June | 0.146291E+10 | 0.682099E+09 | 0.00 | 9526894.82 | 94711194.46 | 0.00 | 0.414715E+10 | 0.00 | 2.13 |
July | 0.203168E+10 | 0.108946E+10 | 0.00 | 7118892.80 | 0.359649E+09 | 0.00 | 0.271177E+10 | 0.00 | 2.24 |
August | 0.325106E+10 | 0.544747E+09 | 0.00 | 6955490.48 | 70271502.54 | 0.00 | 0.276015E+10 | 0.00 | 2.19 |
September | 0.365636E+10 | 11841985.13 | 0.00 | 5068494.15 | 0.00 | 0.00 | 0.365667E+10 | 0.00 | 1.48 |
October | 0.590356E+10 | 0.00 | 0.00 | 1214467.68 | 0.00 | 639017.13 | 0.112326E+10 | 0.00 | 0.93 |
November | 0.556740E+10 | 0.00 | 0.00 | 195857.47 | 0.00 | 0.380450E+09 | 0.171601E+09 | 0.00 | 0.77 |
December | 0.390760E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.343067E+10 | 0.00 | 0.00 | 0.75 |
Annual Sum or Average | 0.456246E+11 | 0.234589E+10 | 0.00 | 47195726.44 | 0.531744E+09 | 0.121947E+11 | 0.247431E+11 | 0.00 | 1.31 |
Minimum of Months | 0.146291E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.75 |
Maximum of Months | 0.590356E+10 | 0.108946E+10 | 0.00 | 9526894.82 | 0.359649E+09 | 0.590420E+10 | 0.464481E+10 | 0.00 | 2.24 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.468457E+10 | 0.00 | 0.00 | 2255156.48 | 0.00 | 0.518103E+10 | 0.196983E+10 | 0.00 | 0.71 |
February | 0.401850E+10 | 0.00 | 0.00 | 6061475.17 | 0.00 | 0.198549E+10 | 0.351003E+10 | 0.00 | 0.73 |
March | 0.532497E+10 | 0.00 | 0.00 | 9124919.22 | 0.00 | 0.576311E+09 | 0.502232E+10 | 0.00 | 0.77 |
April | 0.462616E+10 | 11780894.51 | 0.00 | 10291692.36 | 750958.83 | 28020570.49 | 0.744638E+10 | 0.00 | 1.15 |
May | 0.318858E+10 | 32354338.89 | 0.00 | 12384514.06 | 0.00 | 0.00 | 0.598898E+10 | 0.00 | 1.40 |
June | 0.226450E+10 | 0.100566E+10 | 0.00 | 10135402.88 | 0.120392E+09 | 0.00 | 0.387911E+10 | 0.00 | 1.70 |
July | 0.261458E+10 | 0.157739E+10 | 0.00 | 8700364.23 | 0.455561E+09 | 0.00 | 0.285935E+10 | 0.00 | 1.81 |
August | 0.349093E+10 | 0.108025E+10 | 0.00 | 12061328.34 | 19807401.58 | 0.00 | 0.430187E+10 | 0.00 | 2.05 |
September | 0.363984E+10 | 38847292.91 | 0.00 | 12379736.90 | 0.00 | 0.00 | 0.703058E+10 | 0.00 | 1.53 |
October | 0.568303E+10 | 0.00 | 0.00 | 8926210.25 | 0.00 | 49021163.37 | 0.473775E+10 | 0.00 | 0.97 |
November | 0.567615E+10 | 0.00 | 0.00 | 4343976.40 | 0.00 | 0.477725E+09 | 0.273151E+10 | 0.00 | 0.70 |
December | 0.497560E+10 | 0.00 | 0.00 | 1976117.43 | 0.00 | 0.324636E+10 | 0.120558E+10 | 0.00 | 0.63 |
Annual Sum or Average | 0.501874E+11 | 0.374629E+10 | 0.00 | 98640893.73 | 0.596511E+09 | 0.115440E+11 | 0.506833E+11 | 0.00 | 1.18 |
Minimum of Months | 0.226450E+10 | 0.00 | 0.00 | 1976117.43 | 0.00 | 0.00 | 0.120558E+10 | 0.00 | 0.63 |
Maximum of Months | 0.568303E+10 | 0.157739E+10 | 0.00 | 12384514.06 | 0.455561E+09 | 0.518103E+10 | 0.744638E+10 | 0.00 | 2.05 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.585461E+10 | 0.00 | 0.00 | 55570.25 | 0.00 | 0.501488E+10 | 0.138683E+09 | 0.00 | 1.02 |
February | 0.631454E+10 | 0.00 | 0.00 | 1111448.24 | 0.00 | 0.589872E+09 | 0.105478E+10 | 0.00 | 0.96 |
March | 0.555534E+10 | 0.00 | 0.00 | 5483617.97 | 0.00 | 3989242.15 | 0.384625E+10 | 0.00 | 1.06 |
April | 0.193291E+10 | 4865321.72 | 0.00 | 12819543.38 | 4470057.43 | 0.00 | 0.912265E+10 | 0.00 | 1.60 |
May | 0.217835E+10 | 28388704.94 | 0.00 | 13483340.02 | 0.00 | 0.00 | 0.628939E+10 | 0.00 | 1.98 |
June | 0.121885E+10 | 0.985935E+09 | 0.00 | 12755128.07 | 97173508.43 | 0.00 | 0.478408E+10 | 0.00 | 2.59 |
July | 0.176758E+10 | 0.165487E+10 | 0.00 | 13551613.62 | 0.374746E+09 | 0.00 | 0.365534E+10 | 0.00 | 2.81 |
August | 0.222050E+10 | 0.100701E+10 | 0.00 | 17394458.65 | 10285372.23 | 0.00 | 0.567941E+10 | 0.00 | 3.12 |
September | 0.327143E+10 | 15919037.63 | 0.00 | 7644765.19 | 0.00 | 0.00 | 0.531220E+10 | 0.00 | 1.81 |
October | 0.457511E+10 | 0.00 | 0.00 | 4234565.34 | 0.00 | 0.00 | 0.425287E+10 | 0.00 | 1.20 |
November | 0.506108E+10 | 0.00 | 0.00 | 1783243.57 | 0.00 | 2565603.15 | 0.244935E+10 | 0.00 | 0.95 |
December | 0.824937E+10 | 0.00 | 0.00 | 172078.61 | 0.00 | 0.199560E+09 | 0.428824E+09 | 0.00 | 0.91 |
Annual Sum or Average | 0.481997E+11 | 0.369698E+10 | 0.00 | 90489372.92 | 0.486675E+09 | 0.581086E+10 | 0.470138E+11 | 0.00 | 1.67 |
Minimum of Months | 0.121885E+10 | 0.00 | 0.00 | 55570.25 | 0.00 | 0.00 | 0.138683E+09 | 0.00 | 0.91 |
Maximum of Months | 0.824937E+10 | 0.165487E+10 | 0.00 | 17394458.65 | 0.374746E+09 | 0.501488E+10 | 0.912265E+10 | 0.00 | 3.12 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.130381E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.737116E+11 | 0.00 | 0.00 | 0.47 |
February | 0.564819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.426915E+11 | 0.00 | 0.00 | 0.44 |
March | 0.200513E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.254044E+11 | 0.00 | 0.00 | 0.44 |
April | 0.324321E+11 | 0.00 | 0.00 | 5720069.83 | 0.115688E+09 | 0.475619E+10 | 0.512740E+10 | 0.00 | 0.44 |
May | 0.172842E+11 | 0.259007E+09 | 0.00 | 67118269.98 | 0.00 | 8798830.91 | 0.296224E+11 | 0.00 | 0.77 |
June | 0.515245E+10 | 0.777152E+10 | 0.00 | 78752548.48 | 0.523219E+09 | 0.00 | 0.304967E+11 | 0.00 | 1.08 |
July | 0.579049E+10 | 0.107913E+11 | 0.00 | 64380104.29 | 0.918325E+09 | 0.00 | 0.213693E+11 | 0.00 | 1.03 |
August | 0.106783E+11 | 0.555125E+10 | 0.00 | 53544618.42 | 87799906.82 | 0.00 | 0.222984E+11 | 0.00 | 0.97 |
September | 0.249410E+11 | 0.148048E+09 | 0.00 | 29922850.43 | 0.00 | 0.00 | 0.193710E+11 | 0.00 | 0.63 |
October | 0.378457E+11 | 0.00 | 0.00 | 1373552.50 | 0.00 | 0.336561E+10 | 0.175083E+10 | 0.00 | 0.43 |
November | 0.201579E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192809E+11 | 0.00 | 0.00 | 0.42 |
December | 0.222189E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.569192E+11 | 0.00 | 0.00 | 0.44 |
Annual Sum or Average | 0.183507E+12 | 0.245211E+11 | 0.00 | 0.300812E+09 | 0.164503E+10 | 0.226138E+12 | 0.130036E+12 | 0.00 | 0.63 |
Minimum of Months | 0.130381E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 0.378457E+11 | 0.107913E+11 | 0.00 | 78752548.48 | 0.918325E+09 | 0.737116E+11 | 0.304967E+11 | 0.00 | 1.08 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.652705E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.892254E+11 | 0.00 | 0.00 | 0.97 |
February | 0.179599E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.490655E+11 | 0.00 | 0.00 | 0.98 |
March | 0.369372E+11 | 0.00 | 0.00 | 7445469.21 | 0.00 | 0.267197E+11 | 0.383496E+10 | 0.00 | 1.02 |
April | 0.383070E+11 | 0.00 | 0.00 | 38833802.24 | 0.173850E+09 | 0.495699E+10 | 0.273914E+11 | 0.00 | 1.13 |
May | 0.304137E+11 | 0.197020E+09 | 0.00 | 74712846.45 | 0.00 | 0.00 | 0.361148E+11 | 0.00 | 1.57 |
June | 0.126602E+11 | 0.670710E+10 | 0.00 | 90854694.01 | 0.976043E+09 | 0.00 | 0.379599E+11 | 0.00 | 2.04 |
July | 0.110842E+11 | 0.105842E+11 | 0.00 | 72189022.51 | 0.172692E+10 | 0.00 | 0.271798E+11 | 0.00 | 1.99 |
August | 0.248089E+11 | 0.472467E+10 | 0.00 | 60029591.31 | 0.926999E+09 | 0.00 | 0.206375E+11 | 0.00 | 1.89 |
September | 0.450675E+11 | 0.150718E+09 | 0.00 | 35180160.41 | 0.00 | 6891194.57 | 0.226380E+11 | 0.00 | 1.44 |
October | 0.558348E+11 | 0.00 | 0.00 | 5251063.26 | 0.00 | 0.518524E+10 | 0.392064E+10 | 0.00 | 1.01 |
November | 0.319002E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.264360E+11 | 0.00 | 0.00 | 0.97 |
December | 0.520870E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.728767E+11 | 0.00 | 0.00 | 0.97 |
Annual Sum or Average | 0.316709E+12 | 0.223637E+11 | 0.00 | 0.384497E+09 | 0.380382E+10 | 0.274472E+12 | 0.179677E+12 | 0.00 | 1.33 |
Minimum of Months | 0.520870E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.97 |
Maximum of Months | 0.558348E+11 | 0.105842E+11 | 0.00 | 90854694.01 | 0.172692E+10 | 0.892254E+11 | 0.379599E+11 | 0.00 | 2.04 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.325669E+11 | 0.00 | 0.00 | 16695471.34 | 0.00 | 0.727498E+11 | 0.133880E+11 | 0.00 | 0.78 |
February | 0.287221E+11 | 0.00 | 0.00 | 44688193.63 | 0.00 | 0.389113E+11 | 0.224674E+11 | 0.00 | 0.86 |
March | 0.377299E+11 | 0.00 | 0.00 | 76265928.82 | 0.00 | 0.217381E+11 | 0.373736E+11 | 0.00 | 0.91 |
April | 0.395049E+11 | 0.254155E+09 | 0.00 | 83885259.25 | 26365086.76 | 0.475888E+10 | 0.581304E+11 | 0.00 | 1.11 |
May | 0.326865E+11 | 0.354534E+09 | 0.00 | 0.110938E+09 | 0.00 | 0.00 | 0.489471E+11 | 0.00 | 1.32 |
June | 0.207910E+11 | 0.944427E+10 | 0.00 | 86244865.46 | 0.110405E+10 | 0.00 | 0.311595E+11 | 0.00 | 1.54 |
July | 0.160288E+11 | 0.148731E+11 | 0.00 | 77884907.88 | 0.183158E+10 | 0.00 | 0.244193E+11 | 0.00 | 1.50 |
August | 0.242249E+11 | 0.925848E+10 | 0.00 | 91067197.44 | 0.232587E+09 | 0.00 | 0.315777E+11 | 0.00 | 1.68 |
September | 0.396011E+11 | 0.477286E+09 | 0.00 | 0.113402E+09 | 0.00 | 0.00 | 0.581175E+11 | 0.00 | 1.48 |
October | 0.537061E+11 | 0.00 | 0.00 | 82407299.87 | 0.00 | 0.419513E+10 | 0.365889E+11 | 0.00 | 1.01 |
November | 0.393075E+11 | 0.00 | 0.00 | 30250714.27 | 0.00 | 0.213851E+11 | 0.177726E+11 | 0.00 | 0.82 |
December | 0.224077E+11 | 0.00 | 0.00 | 6067124.19 | 0.00 | 0.672323E+11 | 0.469464E+10 | 0.00 | 0.75 |
Annual Sum or Average | 0.387277E+12 | 0.346618E+11 | 0.00 | 0.819797E+09 | 0.319457E+10 | 0.230971E+12 | 0.384637E+12 | 0.00 | 1.15 |
Minimum of Months | 0.160288E+11 | 0.00 | 0.00 | 6067124.19 | 0.00 | 0.00 | 0.469464E+10 | 0.00 | 0.75 |
Maximum of Months | 0.537061E+11 | 0.148731E+11 | 0.00 | 0.113402E+09 | 0.183158E+10 | 0.727498E+11 | 0.581304E+11 | 0.00 | 1.68 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.101472E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.905294E+11 | 0.00 | 0.00 | 1.02 |
February | 0.205556E+11 | 0.00 | 0.00 | 1321551.26 | 0.00 | 0.487453E+11 | 0.123742E+10 | 0.00 | 1.03 |
March | 0.416175E+11 | 0.00 | 0.00 | 10396445.51 | 0.00 | 0.233037E+11 | 0.755405E+10 | 0.00 | 1.09 |
April | 0.475002E+11 | 2924445.21 | 0.00 | 34059149.90 | 0.181010E+09 | 0.315384E+10 | 0.239776E+11 | 0.00 | 1.23 |
May | 0.318212E+11 | 0.287459E+09 | 0.00 | 90245667.14 | 0.00 | 0.00 | 0.357367E+11 | 0.00 | 1.68 |
June | 0.175619E+11 | 0.775480E+10 | 0.00 | 71212247.74 | 0.803298E+09 | 0.00 | 0.258184E+11 | 0.00 | 1.99 |
July | 0.120336E+11 | 0.122145E+11 | 0.00 | 70350911.72 | 0.118694E+10 | 0.00 | 0.211027E+11 | 0.00 | 1.90 |
August | 0.240559E+11 | 0.605933E+10 | 0.00 | 53532904.32 | 0.359967E+09 | 0.00 | 0.208901E+11 | 0.00 | 1.94 |
September | 0.500236E+11 | 0.175987E+09 | 0.00 | 33778658.47 | 0.00 | 5872295.56 | 0.193294E+11 | 0.00 | 1.51 |
October | 0.587372E+11 | 0.00 | 0.00 | 9419736.35 | 0.00 | 0.414588E+10 | 0.629778E+10 | 0.00 | 1.08 |
November | 0.393919E+11 | 0.00 | 0.00 | 150593.02 | 0.00 | 0.215978E+11 | 0.425464E+09 | 0.00 | 1.02 |
December | 0.106004E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.714919E+11 | 0.00 | 0.00 | 1.02 |
Annual Sum or Average | 0.364046E+12 | 0.264950E+11 | 0.00 | 0.374468E+09 | 0.253122E+10 | 0.262974E+12 | 0.162370E+12 | 0.00 | 1.38 |
Minimum of Months | 0.101472E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.02 |
Maximum of Months | 0.587372E+11 | 0.122145E+11 | 0.00 | 90245667.14 | 0.118694E+10 | 0.905294E+11 | 0.357367E+11 | 0.00 | 1.99 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 39505292.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.858862E+10 | 0.00 | 0.00 | 0.57 |
February | 0.295841E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.506913E+10 | 0.00 | 0.00 | 0.54 |
March | 0.120762E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.364233E+10 | 0.00 | 0.00 | 0.56 |
April | 0.316296E+10 | 0.00 | 0.00 | 181673.84 | 16871355.78 | 0.138057E+10 | 0.200757E+09 | 0.00 | 0.57 |
May | 0.274341E+10 | 25871525.96 | 0.00 | 4942442.65 | 0.00 | 86848277.88 | 0.203514E+10 | 0.00 | 0.82 |
June | 0.107695E+10 | 0.758929E+09 | 0.00 | 6566971.06 | 93252165.10 | 0.00 | 0.254837E+10 | 0.00 | 1.11 |
July | 0.819194E+09 | 0.114343E+10 | 0.00 | 5467730.90 | 0.152917E+09 | 0.00 | 0.190675E+10 | 0.00 | 1.07 |
August | 0.181894E+10 | 0.577180E+09 | 0.00 | 3890245.93 | 19852548.80 | 0.00 | 0.162465E+10 | 0.00 | 1.03 |
September | 0.390797E+10 | 11157561.91 | 0.00 | 1124320.36 | 0.00 | 0.161857E+09 | 0.779102E+09 | 0.00 | 0.71 |
October | 0.314409E+10 | 0.00 | 0.00 | 2267.33 | 0.00 | 0.146613E+10 | 12820855.72 | 0.00 | 0.56 |
November | 0.103735E+10 | 0.00 | 14431.90 | 0.00 | 0.00 | 0.303292E+10 | 0.00 | 56083.47 | 0.54 |
December | 56027522.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.645410E+10 | 0.00 | 0.00 | 0.55 |
Annual Sum or Average | 0.193099E+11 | 0.251656E+10 | 14431.90 | 22175652.07 | 0.282893E+09 | 0.298825E+11 | 0.910759E+10 | 56083.47 | 0.72 |
Minimum of Months | 39505292.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.54 |
Maximum of Months | 0.390797E+10 | 0.114343E+10 | 14431.90 | 6566971.06 | 0.152917E+09 | 0.858862E+10 | 0.254837E+10 | 56083.47 | 1.11 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 45053314.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.787623E+10 | 0.00 | 0.00 | 0.88 |
February | 0.739343E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.463229E+10 | 0.00 | 0.00 | 0.90 |
March | 0.234336E+10 | 0.00 | 0.00 | 73267.44 | 0.00 | 0.293622E+10 | 89647901.43 | 0.00 | 0.97 |
April | 0.290035E+10 | 0.00 | 0.00 | 2664464.54 | 19272452.33 | 0.932017E+09 | 0.201655E+10 | 0.00 | 1.09 |
May | 0.287301E+10 | 19845993.63 | 0.00 | 6687858.86 | 0.00 | 53864195.36 | 0.305159E+10 | 0.00 | 1.53 |
June | 0.111103E+10 | 0.677486E+09 | 0.00 | 8693727.55 | 0.115226E+09 | 419697.03 | 0.369757E+10 | 0.00 | 2.04 |
July | 0.868168E+09 | 0.111377E+10 | 0.00 | 7347963.63 | 0.193720E+09 | 0.00 | 0.273759E+10 | 0.00 | 2.02 |
August | 0.226515E+10 | 0.498779E+09 | 0.00 | 5857554.25 | 83883813.59 | 1265312.92 | 0.192796E+10 | 0.00 | 1.88 |
September | 0.390690E+10 | 10596205.79 | 0.00 | 3022760.00 | 0.00 | 0.165553E+09 | 0.187372E+10 | 0.00 | 1.36 |
October | 0.354538E+10 | 0.00 | 0.00 | 289726.21 | 0.00 | 0.144863E+10 | 0.280192E+09 | 0.00 | 1.00 |
November | 0.164430E+10 | 0.00 | 19250.32 | 0.00 | 8979.91 | 0.289314E+10 | 0.00 | 41889.39 | 0.94 |
December | 0.138583E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.609656E+10 | 0.00 | 0.00 | 0.88 |
Annual Sum or Average | 0.223806E+11 | 0.232048E+10 | 19250.32 | 34637322.48 | 0.412111E+09 | 0.270362E+11 | 0.156748E+11 | 41889.39 | 1.29 |
Minimum of Months | 45053314.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.88 |
Maximum of Months | 0.390690E+10 | 0.111377E+10 | 19250.32 | 8693727.55 | 0.193720E+09 | 0.787623E+10 | 0.369757E+10 | 41889.39 | 2.04 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.241169E+10 | 0.00 | 0.00 | 774759.10 | 0.00 | 0.735286E+10 | 0.497186E+09 | 0.00 | 0.73 |
February | 0.195677E+10 | 0.00 | 0.00 | 2827500.94 | 0.00 | 0.408075E+10 | 0.141741E+10 | 0.00 | 0.80 |
March | 0.260009E+10 | 0.00 | 0.00 | 4144187.10 | 0.00 | 0.284002E+10 | 0.230018E+10 | 0.00 | 0.87 |
April | 0.310217E+10 | 24919083.31 | 0.00 | 6585245.05 | 5205580.39 | 0.111463E+10 | 0.481129E+10 | 0.00 | 1.09 |
May | 0.339909E+10 | 34065913.79 | 0.00 | 9592129.08 | 0.00 | 0.129129E+09 | 0.420749E+10 | 0.00 | 1.33 |
June | 0.209864E+10 | 0.917013E+09 | 0.00 | 8253356.63 | 0.156610E+09 | 0.00 | 0.311156E+10 | 0.00 | 1.57 |
July | 0.146258E+10 | 0.145990E+10 | 0.00 | 7666728.73 | 0.322842E+09 | 0.00 | 0.251928E+10 | 0.00 | 1.56 |
August | 0.260310E+10 | 0.965573E+09 | 0.00 | 9768190.97 | 36987764.74 | 771843.95 | 0.287355E+10 | 0.00 | 1.73 |
September | 0.402263E+10 | 35535971.45 | 0.00 | 9099827.84 | 0.00 | 0.192621E+09 | 0.484125E+10 | 0.00 | 1.43 |
October | 0.409767E+10 | 0.00 | 0.00 | 6115145.12 | 0.00 | 0.131017E+10 | 0.270006E+10 | 0.00 | 1.02 |
November | 0.245692E+10 | 0.00 | 21750.65 | 1943437.57 | 11371.12 | 0.263929E+10 | 0.109220E+10 | 55669.62 | 0.81 |
December | 0.131499E+10 | 0.00 | 0.00 | 116981.62 | 0.00 | 0.655625E+10 | 0.132059E+09 | 0.00 | 0.72 |
Annual Sum or Average | 0.315263E+11 | 0.343701E+10 | 21750.65 | 66887489.74 | 0.521657E+09 | 0.262165E+11 | 0.305035E+11 | 55669.62 | 1.14 |
Minimum of Months | 0.131499E+10 | 0.00 | 0.00 | 116981.62 | 0.00 | 0.00 | 0.132059E+09 | 0.00 | 0.72 |
Maximum of Months | 0.409767E+10 | 0.145990E+10 | 21750.65 | 9768190.97 | 0.322842E+09 | 0.735286E+10 | 0.484125E+10 | 55669.62 | 1.73 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.447056E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.823954E+10 | 0.00 | 0.00 | 0.96 |
February | 0.118135E+10 | 0.00 | 0.00 | 68974.41 | 0.00 | 0.462513E+10 | 0.105000E+09 | 0.00 | 0.99 |
March | 0.251089E+10 | 0.00 | 0.00 | 704667.91 | 0.00 | 0.300941E+10 | 0.516984E+09 | 0.00 | 1.09 |
April | 0.372532E+10 | 47835.67 | 0.00 | 2824442.14 | 21302492.59 | 0.846770E+09 | 0.214640E+10 | 0.00 | 1.26 |
May | 0.339605E+10 | 27103206.13 | 0.00 | 7989854.81 | 0.00 | 62919634.93 | 0.301492E+10 | 0.00 | 1.69 |
June | 0.183259E+10 | 0.749435E+09 | 0.00 | 6822918.15 | 0.128324E+09 | 0.00 | 0.250353E+10 | 0.00 | 2.04 |
July | 0.116623E+10 | 0.118599E+10 | 0.00 | 6446776.18 | 0.240525E+09 | 0.00 | 0.204838E+10 | 0.00 | 1.95 |
August | 0.254312E+10 | 0.650611E+09 | 0.00 | 5082460.60 | 46471784.39 | 0.00 | 0.182363E+10 | 0.00 | 2.00 |
September | 0.480254E+10 | 13289851.51 | 0.00 | 2805923.54 | 0.00 | 0.116308E+09 | 0.156271E+10 | 0.00 | 1.50 |
October | 0.428626E+10 | 0.00 | 0.00 | 730778.11 | 0.00 | 0.106520E+10 | 0.544180E+09 | 0.00 | 1.12 |
November | 0.217894E+10 | 0.00 | 22712.38 | 0.00 | 23804.07 | 0.283353E+10 | 0.00 | 31041.35 | 1.04 |
December | 0.378647E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.645471E+10 | 0.00 | 0.00 | 0.96 |
Annual Sum or Average | 0.284490E+11 | 0.262648E+10 | 22712.38 | 33476795.86 | 0.436647E+09 | 0.272535E+11 | 0.142657E+11 | 31041.35 | 1.39 |
Minimum of Months | 0.378647E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.96 |
Maximum of Months | 0.480254E+10 | 0.118599E+10 | 22712.38 | 7989854.81 | 0.240525E+09 | 0.823954E+10 | 0.301492E+10 | 31041.35 | 2.04 |
Report: MechanicalVentilationLoadsMonthly
For: DATACENTER_BOT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 40140662.46 | 0.00 | 0.00 | 2049949.06 | 0.00 | 0.00 | 0.109553E+10 | 0.00 | 0.28 |
February | 0.00 | 0.00 | 0.00 | 7611509.35 | 0.00 | 0.00 | 0.889471E+09 | 0.00 | 0.28 |
March | 0.00 | 0.00 | 0.00 | 16079930.23 | 0.00 | 0.00 | 0.889180E+09 | 0.00 | 0.30 |
April | 0.00 | 0.00 | 0.00 | 18648420.12 | 0.00 | 0.00 | 0.565258E+09 | 0.00 | 0.29 |
May | 0.00 | 4130969.57 | 0.00 | 3901611.42 | 0.00 | 0.00 | 0.329789E+09 | 0.00 | 0.29 |
June | 0.00 | 82074673.55 | 0.00 | 5465896.09 | 0.00 | 0.00 | 0.149854E+09 | 0.00 | 0.31 |
July | 0.00 | 0.115905E+09 | 0.00 | 5300127.94 | 0.00 | 0.00 | 59077938.75 | 0.00 | 0.28 |
August | 0.00 | 76028234.14 | 0.00 | 10018234.73 | 0.00 | 0.00 | 85608373.31 | 0.00 | 0.31 |
September | 0.00 | 1003142.71 | 0.00 | 3654273.16 | 0.00 | 0.00 | 0.353170E+09 | 0.00 | 0.29 |
October | 0.00 | 0.00 | 0.00 | 8342896.37 | 0.00 | 0.00 | 0.563773E+09 | 0.00 | 0.28 |
November | 0.00 | 0.00 | 0.00 | 12560257.69 | 0.00 | 0.00 | 0.695261E+09 | 0.00 | 0.28 |
December | 0.00 | 0.00 | 0.00 | 17077737.74 | 0.00 | 0.00 | 0.102175E+10 | 0.00 | 0.28 |
Annual Sum or Average | 40140662.46 | 0.279142E+09 | 0.00 | 0.110711E+09 | 0.00 | 0.00 | 0.669772E+10 | 0.00 | 0.29 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 2049949.06 | 0.00 | 0.00 | 59077938.75 | 0.00 | 0.28 |
Maximum of Months | 40140662.46 | 0.115905E+09 | 0.00 | 18648420.12 | 0.00 | 0.00 | 0.109553E+10 | 0.00 | 0.31 |
Report: MechanicalVentilationLoadsMonthly
For: DATACENTER_MID_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.665507E+10 | 0.00 | 0.00 | 5106392.11 | 0.00 | 0.00 | 0.448770E+10 | 0.00 | 0.28 |
February | 0.00 | 0.00 | 0.00 | 56017717.59 | 0.00 | 0.00 | 0.891444E+10 | 0.00 | 0.28 |
March | 0.00 | 0.00 | 0.00 | 0.136796E+09 | 0.00 | 0.00 | 0.891540E+10 | 0.00 | 0.30 |
April | 0.00 | 0.00 | 0.00 | 0.168736E+09 | 0.00 | 0.00 | 0.566962E+10 | 0.00 | 0.29 |
May | 0.00 | 40377630.19 | 0.00 | 33859832.96 | 0.00 | 0.00 | 0.330534E+10 | 0.00 | 0.29 |
June | 0.00 | 0.814513E+09 | 0.00 | 50821985.00 | 0.00 | 0.00 | 0.150281E+10 | 0.00 | 0.31 |
July | 0.00 | 0.115522E+10 | 0.00 | 50124972.35 | 0.00 | 0.00 | 0.593463E+09 | 0.00 | 0.28 |
August | 0.00 | 0.758316E+09 | 0.00 | 94217063.39 | 0.00 | 0.00 | 0.861613E+09 | 0.00 | 0.31 |
September | 0.00 | 8371893.57 | 0.00 | 29703792.50 | 0.00 | 0.00 | 0.354845E+10 | 0.00 | 0.29 |
October | 0.00 | 0.00 | 0.00 | 69353932.95 | 0.00 | 0.00 | 0.565031E+10 | 0.00 | 0.28 |
November | 0.00 | 0.00 | 0.00 | 0.104248E+09 | 0.00 | 0.00 | 0.697244E+10 | 0.00 | 0.28 |
December | 0.00 | 0.00 | 0.00 | 0.142627E+09 | 0.00 | 0.00 | 0.102448E+11 | 0.00 | 0.28 |
Annual Sum or Average | 0.665507E+10 | 0.277680E+10 | 0.00 | 0.941612E+09 | 0.00 | 0.00 | 0.606664E+11 | 0.00 | 0.29 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 5106392.11 | 0.00 | 0.00 | 0.593463E+09 | 0.00 | 0.28 |
Maximum of Months | 0.665507E+10 | 0.115522E+10 | 0.00 | 0.168736E+09 | 0.00 | 0.00 | 0.102448E+11 | 0.00 | 0.31 |
Report: MechanicalVentilationLoadsMonthly
For: DATACENTER_TOP_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.920956E+09 | 0.00 | 0.00 | 199794.11 | 0.00 | 0.00 | 0.167893E+09 | 0.00 | 0.28 |
February | 404194.08 | 0.00 | 0.00 | 4525008.39 | 0.00 | 0.00 | 0.892041E+09 | 0.00 | 0.28 |
March | 0.00 | 0.00 | 0.00 | 12293076.59 | 0.00 | 0.00 | 0.892940E+09 | 0.00 | 0.30 |
April | 0.00 | 0.00 | 0.00 | 15992584.24 | 0.00 | 0.00 | 0.567864E+09 | 0.00 | 0.29 |
May | 3104661.10 | 4076501.66 | 0.00 | 3084820.36 | 0.00 | 0.00 | 0.327700E+09 | 0.00 | 0.29 |
June | 0.00 | 81385173.22 | 0.00 | 4996848.94 | 0.00 | 0.00 | 0.150532E+09 | 0.00 | 0.31 |
July | 0.00 | 0.115514E+09 | 0.00 | 4964099.22 | 0.00 | 0.00 | 59470055.05 | 0.00 | 0.28 |
August | 0.00 | 75760907.26 | 0.00 | 9306432.39 | 0.00 | 0.00 | 86412521.20 | 0.00 | 0.31 |
September | 0.00 | 839404.55 | 0.00 | 2529388.30 | 0.00 | 0.00 | 0.356178E+09 | 0.00 | 0.29 |
October | 0.00 | 0.00 | 0.00 | 5959077.09 | 0.00 | 0.00 | 0.566148E+09 | 0.00 | 0.28 |
November | 0.00 | 0.00 | 0.00 | 9335957.63 | 0.00 | 0.00 | 0.698448E+09 | 0.00 | 0.28 |
December | 0.00 | 0.00 | 0.00 | 13249242.03 | 0.00 | 0.00 | 0.102552E+10 | 0.00 | 0.28 |
Annual Sum or Average | 0.924465E+09 | 0.277576E+09 | 0.00 | 86436329.29 | 0.00 | 0.00 | 0.579115E+10 | 0.00 | 0.29 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 199794.11 | 0.00 | 0.00 | 59470055.05 | 0.00 | 0.28 |
Maximum of Months | 0.920956E+09 | 0.115514E+09 | 0.00 | 15992584.24 | 0.00 | 0.00 | 0.102552E+10 | 0.00 | 0.31 |
Report: MechanicalVentilationLoadsMonthly
For: DATACENTER_BASEMENT_ZN_6
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.223749E+09 | 0.00 | 0.00 | 0.299850E+11 | 0.00 | 0.32 |
February | 0.00 | 0.00 | 0.00 | 0.446400E+09 | 0.00 | 0.00 | 0.238186E+11 | 0.00 | 0.32 |
March | 0.00 | 0.00 | 0.00 | 0.838663E+09 | 0.00 | 0.00 | 0.234077E+11 | 0.00 | 0.34 |
April | 0.00 | 0.00 | 0.00 | 0.929763E+09 | 0.00 | 0.00 | 0.151617E+11 | 0.00 | 0.32 |
May | 0.00 | 0.113593E+09 | 0.00 | 0.200920E+09 | 0.00 | 0.00 | 0.799641E+10 | 0.00 | 0.33 |
June | 0.00 | 0.190599E+10 | 0.00 | 0.265130E+09 | 0.00 | 0.00 | 0.320146E+10 | 0.00 | 0.34 |
July | 0.00 | 0.261352E+10 | 0.00 | 0.255693E+09 | 0.00 | 0.00 | 0.113356E+10 | 0.00 | 0.32 |
August | 0.00 | 0.146524E+10 | 0.00 | 0.472234E+09 | 0.00 | 0.00 | 0.160503E+10 | 0.00 | 0.35 |
September | 0.00 | 40944228.46 | 0.00 | 0.200607E+09 | 0.00 | 0.00 | 0.763113E+10 | 0.00 | 0.33 |
October | 0.00 | 0.00 | 0.00 | 0.444290E+09 | 0.00 | 0.00 | 0.130227E+11 | 0.00 | 0.32 |
November | 0.00 | 0.00 | 0.00 | 0.664456E+09 | 0.00 | 0.00 | 0.179630E+11 | 0.00 | 0.32 |
December | 0.00 | 0.00 | 0.00 | 0.913298E+09 | 0.00 | 0.00 | 0.267910E+11 | 0.00 | 0.31 |
Annual Sum or Average | 0.00 | 0.613928E+10 | 0.00 | 0.585520E+10 | 0.00 | 0.00 | 0.171717E+12 | 0.00 | 0.33 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.200607E+09 | 0.00 | 0.00 | 0.113356E+10 | 0.00 | 0.31 |
Maximum of Months | 0.00 | 0.261352E+10 | 0.00 | 0.929763E+09 | 0.00 | 0.00 | 0.299850E+11 | 0.00 | 0.35 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 09:03:35
Custom Monthly ReportSITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
January | 0.300240E+12 | 0.506645E+11 | 0.00 | 0.244539E+13 | 0.708259E+12 |
February | 0.413158E+12 | 0.445398E+11 | 0.00 | 0.217885E+13 | 0.902580E+12 |
March | 0.583280E+12 | 0.316022E+11 | 0.00 | 0.249871E+13 | 0.133075E+13 |
April | 0.717473E+12 | 0.286566E+11 | 0.00 | 0.223307E+13 | 0.170133E+13 |
May | 0.821236E+12 | 0.143925E+11 | 0.00 | 0.217988E+13 | 0.107644E+13 |
June | 0.833823E+12 | 0.539981E+10 | 0.00 | 0.134656E+13 | 0.209834E+13 |
July | 0.859141E+12 | 0.262216E+10 | 0.00 | 0.983853E+12 | 0.287896E+13 |
August | 0.718940E+12 | 0.683272E+10 | 0.00 | 0.151335E+13 | 0.292951E+13 |
September | 0.528414E+12 | 0.134026E+11 | 0.00 | 0.219159E+13 | 0.810356E+12 |
October | 0.318814E+12 | 0.206001E+11 | 0.00 | 0.234499E+13 | 0.964692E+12 |
November | 0.178187E+12 | 0.356510E+11 | 0.00 | 0.212963E+13 | 0.129164E+13 |
December | 0.225153E+12 | 0.546637E+11 | 0.00 | 0.237895E+13 | 0.180431E+13 |
Annual Sum or Average | 0.649786E+13 | 0.309028E+12 | 0.00 | 0.244248E+14 | 0.184972E+14 |
Minimum of Months | 0.178187E+12 | 0.262216E+10 | 0.00 | 0.983853E+12 | 0.708259E+12 |
Maximum of Months | 0.859141E+12 | 0.546637E+11 | 0.00 | 0.249871E+13 | 0.292951E+13 |