Table of Contents

Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:05

Tabular Output Report in Format: HTML

Building: OfficeLarge

Environment: RUNPERIOD 1 ** Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190

Simulation Timestamp: 2023-10-16 09:05:17


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 32392.04 699.30 699.30
Net Site Energy 32392.04 699.30 699.30
Total Source Energy 85309.86 1841.73 1841.73
Net Source Energy 85309.86 1841.73 1841.73


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 1.200
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil No 1 1.050
Fuel Oil No 2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 46320.38
Net Conditioned Building Area 46320.38
Unconditioned Building Area 0.00


End Uses

Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 0.00 375.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 1574.96 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 7163.44 0.00 0.00
Interior Lighting 2029.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 327.97 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 14676.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 3258.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 1159.91 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 647.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 475.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 6675.52
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 45.36 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 657.70 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2280.17
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total End Uses 24195.80 1032.81 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 7163.44 0.00 8955.68
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Boiler 0.00 375.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 1574.96 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 7163.44 0.00 0.00
Interior Lighting LightsWired 2029.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 327.97 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 5334.97 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  DataCenterPlugLoads 9341.42 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment Transformer 54.48 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ComputerHVAC 1349.07 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ElevatorLift 1848.78 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ElevatorLightsFan 5.83 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans General 1159.91 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps General 647.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 475.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 6675.52
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 45.36 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2280.17
  Water Heater 0.00 657.70 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


End Uses By Space Type

Space Type Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Unassigned 0.00 375.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling Unassigned 1574.96 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 7163.44 0.00 0.00
Interior Lighting GENERAL 2029.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting Unassigned 327.97 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment GENERAL 14676.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment Unassigned 3258.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans Unassigned 1159.91 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps Unassigned 647.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection Unassigned 475.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 6675.52
Humidification Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery Unassigned 45.36 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Unassigned 0.00 657.70 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2280.17
Refrigeration Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Gasoline Intensity [MJ/m2] Diesel Intensity [MJ/m2] Coal Intensity [MJ/m2] Fuel Oil No 1 Intensity [MJ/m2] Fuel Oil No 2 Intensity [MJ/m2] Propane Intensity [MJ/m2] Other Fuel 1 Intensity [MJ/m2] Other Fuel 2 Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 50.89 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
HVAC 83.30 22.30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 154.65 0.00 0.19
Other 388.16 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total 522.36 22.30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 154.65 0.00 0.19


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Gasoline Intensity [MJ/m2] Diesel Intensity [MJ/m2] Coal Intensity [MJ/m2] Fuel Oil No 1 Intensity [MJ/m2] Fuel Oil No 2 Intensity [MJ/m2] Propane Intensity [MJ/m2] Other Fuel 1 Intensity [MJ/m2] Other Fuel 2 Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 50.89 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
HVAC 83.30 22.30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 154.65 0.00 0.19
Other 388.16 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total 522.36 22.30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 154.65 0.00 0.19


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.000 0.00
High Temperature Geothermal* 0.000 0.00
Photovoltaic Power 0.000 0.00
Wind Power 0.000 0.00
Power Conversion 0.000 0.00
Net Decrease in On-Site Storage 0.000 0.00
Total On-Site Electric Sources 0.000 0.00
     
Electricity Coming From Utility 24195.798 100.00
Surplus Electricity Going To Utility 0.000 0.00
Net Electricity From Utility 24195.798 100.00
     
Total On-Site and Utility Electric Sources 24195.798 100.00
Total Electricity End Uses 24195.798 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00 0.00
Air to Air Heat Recovery for Cooling 812.27 66.86
Air to Air Heat Recovery for Heating 402.59 33.14
High-Temperature Geothermal* 0.00 0.00
Solar Water Thermal 0.00 0.00
Solar Air Thermal 0.00 0.00
Total On-Site Thermal Sources 1214.86 100.00


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 8955.68 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 8955.68 100.00
Total Water End Uses 8955.68 100.00


Setpoint Not Met Criteria

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.56
Tolerance for Zone Cooling Setpoint Not Met Time 0.56


Comfort and Setpoint Not Met Summary

Facility [Hours]
Time Setpoint Not Met During Occupied Heating 27.33
Time Setpoint Not Met During Occupied Cooling 143.50
Time Not Comfortable Based on Simple ASHRAE 55-2004 5943.00


Note 1: An asterisk (*) indicates that the feature is not yet implemented.

Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Adaptive Comfort Summary
Initialization Summary
Annual Heat Emissions Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
Coil Sizing Details
System Summary
Outdoor Air Summary
Outdoor Air Details
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary
Annual Thermal Resilience Summary
Annual CO2 Resilience Summary
Annual Visual Resilience Summary

NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODENAME IECC

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2021

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND

| Environment |

NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICELARGE

| Environment |

NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL

| Environment |

NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL

| Environment |

NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3A

| Environment |

NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_GA_ATLANTA

| Environment |

ZoneCoolingSummaryMonthly

| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |

ZoneHeatingSummaryMonthly

| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |

ZoneElectricSummaryMonthly

| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |

SpaceGainsMonthly

| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM |

PeakSpaceGainsMonthly

| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM |

SpaceGainComponentsAtCoolingPeakMonthly

| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |

EnergyConsumptionElectricityNaturalGasMonthly

| Meter |

EnergyConsumptionDistrictHeatingCoolingMonthly

| Meter |

EndUseEnergyConsumptionElectricityMonthly

| Meter |

EndUseEnergyConsumptionNaturalGasMonthly

| Meter |

PeakEnergyEndUseElectricityPart1Monthly

| Meter |

PeakEnergyEndUseElectricityPart2Monthly

| Meter |

ElectricComponentsOfPeakDemandMonthly

| Meter |

PeakEnergyEndUseNaturalGasMonthly

| Meter |

SetpointsNotMetWithTemperaturesMonthly

| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |

ComfortReportSimple55Monthly

| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |

OccupantComfortDataSummaryMonthly

| DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 | BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 |

ChillerReportMonthly

| COOLSYS1 CHILLER1 | COOLSYS1 CHILLER2 |

TowerReportMonthly

| CENTRAL TOWER | TOWERWATERSYS COOLTOWER 1 | TOWERWATERSYS COOLTOWER 2 |

BoilerReportMonthly

| HEATSYS1 BOILER | CENTRAL BOILER |

DXReportMonthly

| VAV_BOT WITH REHEAT COOLING COIL | VAV_MID WITH REHEAT COOLING COIL | VAV_TOP WITH REHEAT COOLING COIL | CAV_BAS COOLING COIL | AIRLOOP DATACENTER BOT COOLING COIL | AIRLOOP DATACENTER MID COOLING COIL | AIRLOOP DATACENTER TOP COOLING COIL |

WindowReportMonthly

| PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW |

WindowEnergyReportMonthly

| PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW |

WindowZoneSummaryMonthly

| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |

WindowEnergyZoneSummaryMonthly

| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |

AverageOutdoorConditionsMonthly

| Environment |

OutdoorConditionsMaximumDryBulbMonthly

| Environment |

OutdoorConditionsMinimumDryBulbMonthly

| Environment |

OutdoorConditionsMaximumWetBulbMonthly

| Environment |

OutdoorConditionsMaximumDewPointMonthly

| Environment |

OutdoorGroundConditionsMonthly

| Environment |

WaterHeaterReportMonthly

| SWHSYS1 WATER HEATER |

DaylightingReportMonthly

| PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_4_DAYLCTRL |

CoilReportMonthly

| VAV_BOT WITH REHEAT HEATING COIL | CORE_BOTTOM VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | VAV_MID WITH REHEAT HEATING COIL | CORE_MID VAV BOX REHEAT COIL | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | VAV_TOP WITH REHEAT HEATING COIL | CORE_TOP VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | CAV_BAS HEATING COIL | AIRLOOP DATACENTER BOT HEATING COIL | AIRLOOP DATACENTER MID HEATING COIL | AIRLOOP DATACENTER TOP HEATING COIL | AIRLOOP DATACENTER BOT_SUPPHEATCOIL | AIRLOOP DATACENTER MID_SUPPHEATCOIL | AIRLOOP DATACENTER TOP_SUPPHEATCOIL | VAV_BOT WITH REHEAT COOLING COIL | VAV_MID WITH REHEAT COOLING COIL | VAV_TOP WITH REHEAT COOLING COIL | CAV_BAS COOLING COIL | AIRLOOP DATACENTER BOT COOLING COIL | AIRLOOP DATACENTER MID COOLING COIL | AIRLOOP DATACENTER TOP COOLING COIL |

PlantLoopDemandReportMonthly

| HEATSYS1 | COOLSYS1_SUPPLY | COOLSYS1_DEMAND | SINGLE WATER PLANT LOOP | SWHSYS1 | TOWERWATERSYS |

FanReportMonthly

| CAV_BAS FAN | VAV_BOT WITH REHEAT FAN | VAV_MID WITH REHEAT FAN | VAV_TOP WITH REHEAT FAN | AIRLOOP DATACENTER BOT SUPPLY FAN | AIRLOOP DATACENTER MID SUPPLY FAN | AIRLOOP DATACENTER TOP SUPPLY FAN |

PumpReportMonthly

| HEATSYS1 PUMP | COOLSYS1 PUMP SECONDARY | COOLSYS1 PUMP | PLANT CIRC PUMP | SWHSYS1 PUMP | TOWERWATERSYS PUMP |

CondLoopDemandReportMonthly

| HEATSYS1 | COOLSYS1_SUPPLY | COOLSYS1_DEMAND | SINGLE WATER PLANT LOOP | SWHSYS1 | TOWERWATERSYS |

ZoneTemperatureOscillationReportMonthly

| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | GROUNDFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |

AirLoopSystemEnergyAndWaterUseMonthly

| VAV_BOT WITH REHEAT | VAV_MID WITH REHEAT | VAV_TOP WITH REHEAT | CAV_BAS | AIRLOOP DATACENTER BOT | AIRLOOP DATACENTER MID | AIRLOOP DATACENTER TOP |

AirLoopSystemComponentLoadsMonthly

| VAV_BOT WITH REHEAT | VAV_MID WITH REHEAT | VAV_TOP WITH REHEAT | CAV_BAS | AIRLOOP DATACENTER BOT | AIRLOOP DATACENTER MID | AIRLOOP DATACENTER TOP |

AirLoopSystemComponentEnergyUseMonthly

| VAV_BOT WITH REHEAT | VAV_MID WITH REHEAT | VAV_TOP WITH REHEAT | CAV_BAS | AIRLOOP DATACENTER BOT | AIRLOOP DATACENTER MID | AIRLOOP DATACENTER TOP |

MechanicalVentilationLoadsMonthly

| BASEMENT | CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | DATACENTER_BOT_ZN_6 | DATACENTER_MID_ZN_6 | DATACENTER_TOP_ZN_6 | DATACENTER_BASEMENT_ZN_6 |

HeatEmissionsReportMonthly

| Environment |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

General

Value
Program Version and Build EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 09:05
RunPeriod RUNPERIOD 1
Weather File Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190
Latitude [deg] 33.63
Longitude [deg] -84.4
Elevation [m] 308.00
Time Zone -5.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 12183.89 3655.17 2436.78 3655.17 2436.78
Above Ground Wall Area [m2] 11589.54 3476.86 2317.91 3476.86 2317.91
Window Opening Area [m2] 3476.85 1043.06 695.37 1043.06 695.37
Gross Window-Wall Ratio [%] 28.54 28.54 28.54 28.54 28.54
Above Ground Window-Wall Ratio [%] 30.00 30.00 30.00 30.00 30.00


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 12183.89 3655.17 2436.78 3655.17 2436.78
Above Ground Wall Area [m2] 11589.54 3476.86 2317.91 3476.86 2317.91
Window Opening Area [m2] 3476.85 1043.06 695.37 1043.06 695.37
Gross Window-Wall Ratio [%] 28.54 28.54 28.54 28.54 28.54
Above Ground Window-Wall Ratio [%] 30.00 30.00 30.00 30.00 30.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 3563.11
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Above Ground Gross Wall Area [m2] Underground Gross Wall Area [m2] Window Glass Area [m2] Opening Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
BASEMENT 2779.43 Yes Yes 6779.02 1.00 0.00 397.05 0.00 0.00 5.8895 18.58 4.8418
CORE_BOTTOM 2496.12 Yes Yes 6849.35 1.00 0.00 0.00 0.00 0.00 5.8895 18.58 8.0697
CORE_MID 2496.12 Yes Yes 6849.35 10.00 0.00 0.00 0.00 0.00 5.8895 18.58 8.0696
CORE_TOP 2496.12 Yes Yes 6849.35 1.00 0.00 0.00 0.00 0.00 5.8895 18.58 8.0696
PERIMETER_BOT_ZN_3 313.41 Yes Yes 860.00 1.00 200.61 0.00 86.92 86.92 5.8895 18.58 8.0700
PERIMETER_BOT_ZN_2 201.98 Yes Yes 554.22 1.00 133.74 0.00 57.95 57.95 5.8895 18.58 8.0700
PERIMETER_BOT_ZN_1 313.42 Yes Yes 860.02 1.00 200.61 0.00 86.92 86.92 5.8895 18.58 8.0699
PERIMETER_BOT_ZN_4 201.98 Yes Yes 554.22 1.00 133.74 0.00 57.95 57.95 5.8895 18.58 8.0699
PERIMETER_MID_ZN_3 313.41 Yes Yes 860.00 10.00 200.61 0.00 86.92 86.92 5.8895 18.58 8.0700
PERIMETER_MID_ZN_2 201.98 Yes Yes 554.22 10.00 133.74 0.00 57.95 57.95 5.8895 18.58 8.0700
PERIMETER_MID_ZN_1 313.42 Yes Yes 860.02 10.00 200.61 0.00 86.92 86.92 5.8895 18.58 8.0699
PERIMETER_MID_ZN_4 201.98 Yes Yes 554.22 10.00 133.74 0.00 57.95 57.95 5.8895 18.58 8.0699
PERIMETER_TOP_ZN_3 313.41 Yes Yes 860.00 1.00 200.61 0.00 86.92 86.92 5.8895 18.58 8.0700
PERIMETER_TOP_ZN_2 201.98 Yes Yes 554.22 1.00 133.74 0.00 57.95 57.95 5.8895 18.58 8.0700
PERIMETER_TOP_ZN_1 313.42 Yes Yes 860.02 1.00 200.61 0.00 86.92 86.92 5.8895 18.58 8.0699
PERIMETER_TOP_ZN_4 201.98 Yes Yes 554.22 1.00 133.74 0.00 57.95 57.95 5.8895 18.58 8.0699
GROUNDFLOOR_PLENUM 3563.11 Yes No 4344.14 1.00 297.11 0.00 0.00 0.00 0.0000   0.0000
MIDFLOOR_PLENUM 3563.11 Yes No 4344.14 10.00 297.11 0.00 0.00 0.00 0.0000   0.0000
TOPFLOOR_PLENUM 3563.11 Yes No 4344.14 1.00 297.11 0.00 0.00 0.00 0.0000   0.0000
DATACENTER_BOT_ZN_6 36.20 Yes Yes 99.34 1.00 0.00 0.00 0.00 0.00 8.8011 18.58 215.2992
DATACENTER_MID_ZN_6 36.20 Yes Yes 99.34 10.00 0.00 0.00 0.00 0.00 8.8011 18.58 215.2992
DATACENTER_TOP_ZN_6 36.20 Yes Yes 99.34 1.00 0.00 0.00 0.00 0.00 8.8011 18.58 215.2992
DATACENTER_BASEMENT_ZN_6 783.68 Yes Yes 1911.37 1.00 0.00 197.31 0.00 0.00 5.8895 18.58 484.4232
Total 46320.38     126016.35   8024.24 594.36 3476.85 3476.85 5.9168 18.58 17.8789
Conditioned Total 46320.38     126016.35   8024.24 594.36 3476.85 3476.85 5.9168 18.58 17.8789
Unconditioned Total 0.00     0.00   0.00 0.00 0.00 0.00      
Not Part of Total 42757.27     52129.67   3565.29 0.00 0.00 0.00 0.0000   0.0000


Space Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Multipliers Zone Name Space Type Radiant/Solar Enclosure Name Lighting [W/m2] People [m2 per person] Plug and Process [W/m2] Tags
BASEMENT 2779.43 Yes Yes 1.00 BASEMENT GENERAL BASEMENT 5.8895 18.58 4.8418  
CORE_BOTTOM 2496.12 Yes Yes 1.00 CORE_BOTTOM GENERAL CORE_BOTTOM 5.8895 18.58 8.0697  
CORE_MID 2496.12 Yes Yes 10.00 CORE_MID GENERAL CORE_MID 5.8895 18.58 8.0696  
CORE_TOP 2496.12 Yes Yes 1.00 CORE_TOP GENERAL CORE_TOP 5.8895 18.58 8.0696  
PERIMETER_BOT_ZN_3 313.41 Yes Yes 1.00 PERIMETER_BOT_ZN_3 GENERAL PERIMETER_BOT_ZN_3 5.8895 18.58 8.0700  
PERIMETER_BOT_ZN_2 201.98 Yes Yes 1.00 PERIMETER_BOT_ZN_2 GENERAL PERIMETER_BOT_ZN_2 5.8895 18.58 8.0700  
PERIMETER_BOT_ZN_1 313.42 Yes Yes 1.00 PERIMETER_BOT_ZN_1 GENERAL PERIMETER_BOT_ZN_1 5.8895 18.58 8.0699  
PERIMETER_BOT_ZN_4 201.98 Yes Yes 1.00 PERIMETER_BOT_ZN_4 GENERAL PERIMETER_BOT_ZN_4 5.8895 18.58 8.0699  
PERIMETER_MID_ZN_3 313.41 Yes Yes 10.00 PERIMETER_MID_ZN_3 GENERAL PERIMETER_MID_ZN_3 5.8895 18.58 8.0700  
PERIMETER_MID_ZN_2 201.98 Yes Yes 10.00 PERIMETER_MID_ZN_2 GENERAL PERIMETER_MID_ZN_2 5.8895 18.58 8.0700  
PERIMETER_MID_ZN_1 313.42 Yes Yes 10.00 PERIMETER_MID_ZN_1 GENERAL PERIMETER_MID_ZN_1 5.8895 18.58 8.0699  
PERIMETER_MID_ZN_4 201.98 Yes Yes 10.00 PERIMETER_MID_ZN_4 GENERAL PERIMETER_MID_ZN_4 5.8895 18.58 8.0699  
PERIMETER_TOP_ZN_3 313.41 Yes Yes 1.00 PERIMETER_TOP_ZN_3 GENERAL PERIMETER_TOP_ZN_3 5.8895 18.58 8.0700  
PERIMETER_TOP_ZN_2 201.98 Yes Yes 1.00 PERIMETER_TOP_ZN_2 GENERAL PERIMETER_TOP_ZN_2 5.8895 18.58 8.0700  
PERIMETER_TOP_ZN_1 313.42 Yes Yes 1.00 PERIMETER_TOP_ZN_1 GENERAL PERIMETER_TOP_ZN_1 5.8895 18.58 8.0699  
PERIMETER_TOP_ZN_4 201.98 Yes Yes 1.00 PERIMETER_TOP_ZN_4 GENERAL PERIMETER_TOP_ZN_4 5.8895 18.58 8.0699  
GROUNDFLOOR_PLENUM 3563.11 Yes No 1.00 GROUNDFLOOR_PLENUM GENERAL GROUNDFLOOR_PLENUM 0.0000 0.00 0.0000  
MIDFLOOR_PLENUM 3563.11 Yes No 10.00 MIDFLOOR_PLENUM GENERAL MIDFLOOR_PLENUM 0.0000 0.00 0.0000  
TOPFLOOR_PLENUM 3563.11 Yes No 1.00 TOPFLOOR_PLENUM GENERAL TOPFLOOR_PLENUM 0.0000 0.00 0.0000  
DATACENTER_BOT_ZN_6 36.20 Yes Yes 1.00 DATACENTER_BOT_ZN_6 GENERAL DATACENTER_BOT_ZN_6 8.8011 18.58 215.2992  
DATACENTER_MID_ZN_6 36.20 Yes Yes 10.00 DATACENTER_MID_ZN_6 GENERAL DATACENTER_MID_ZN_6 8.8011 18.58 215.2992  
DATACENTER_TOP_ZN_6 36.20 Yes Yes 1.00 DATACENTER_TOP_ZN_6 GENERAL DATACENTER_TOP_ZN_6 8.8011 18.58 215.2992  
DATACENTER_BASEMENT_ZN_6 783.68 Yes Yes 1.00 DATACENTER_BASEMENT_ZN_6 GENERAL DATACENTER_BASEMENT_ZN_6 5.8895 18.58 484.4232  
Total 46320.38             5.9168 9.29 17.8789  
Conditioned Total 46320.38             5.9168 9.29 17.8789  
Unconditioned Total 0.00             0.0000 0.00 0.0000  
Not Part of Total 42757.27             0.0000 0.00 0.0000  


Space Type Summary

Total Area [m2] Conditioned Area [m2] Unconditioned Area [m2] Not Part of Total Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
GENERAL 46320.38 46320.38 0.00 42757.27 1.8190 60.38 10.8345
Total 46320.38 46320.38 0.00 42757.27      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

End Uses

Electricity [W] Natural Gas [W] Gasoline [W] Diesel [W] Coal [W] Fuel Oil No 1 [W] Fuel Oil No 2 [W] Propane [W] Other Fuel 1 [W] Other Fuel 2 [W] District Cooling [W] District Heating [W] Water [m3/s]
Time of Peak 12-APR-15:20 09-JAN-07:10 - - - - - - - - 07-AUG-13:00 30-JUN-23:30 14-APR-12:39
Heating 0.00 1079376.27 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 15.01 0.00
Cooling 254536.16 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 369582.79 0.00 0.00
Interior Lighting 171235.93 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 778371.69 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 151141.29 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 202658.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 62236.66 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 32456.83 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 29124.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total End Uses 1652636.69 1108500.87 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 369582.79 15.01 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Gasoline [W] Diesel [W] Coal [W] Fuel Oil No 1 [W] Fuel Oil No 2 [W] Propane [W] Other Fuel 1 [W] Other Fuel 2 [W] District Cooling [W] District Heating [W] Water [m3/s]
Heating General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 15.01 0.00
  Boiler 0.00 1079376.27 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 254536.16 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 369582.79 0.00 0.00
Interior Lighting LightsWired 171235.93 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 305206.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  DataCenterPlugLoads 473165.59 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment Transformer 3372.84 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ComputerHVAC 68333.87 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ElevatorLift 79171.38 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ElevatorLightsFan 263.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans General 202658.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps General 62236.66 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 32456.83 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Water Heater 0.00 29124.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Gasoline [GJ] Source Diesel [GJ] Source Coal [GJ] Source Fuel Oil No 1 [GJ] Source Fuel Oil No 2 [GJ] Source Propane [GJ] Source Other Fuel 1 [GJ] Source Other Fuel 2 [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 0.00 406.61 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01
Cooling 4987.89 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 7562.20 0.00
Interior Lighting 6426.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 1038.68 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 46480.15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 10318.63 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 3673.44 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 2051.59 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 1507.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 143.66 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 712.95 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 76628.09 1119.56 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 7562.20 0.01


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Gasoline [MJ/m2] Source Diesel [MJ/m2] Source Coal [MJ/m2] Source Fuel Oil No 1 [MJ/m2] Source Fuel Oil No 2 [MJ/m2] Source Propane [MJ/m2] Source Other Fuel 1 [MJ/m2] Source Other Fuel 2 [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 8.78 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 107.68 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 163.26 0.00
Interior Lighting 138.75 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 22.42 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1003.45 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 222.77 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 79.31 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 44.29 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 32.54 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 3.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 15.39 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 1654.31 24.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 163.26 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Gasoline [MJ/m2] Source Diesel [MJ/m2] Source Coal [MJ/m2] Source Fuel Oil No 1 [MJ/m2] Source Fuel Oil No 2 [MJ/m2] Source Propane [MJ/m2] Source Other Fuel 1 [MJ/m2] Source Other Fuel 2 [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 8.78 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 107.68 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 163.26 0.00
Interior Lighting 138.75 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 22.42 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1003.45 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 222.77 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 79.31 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 44.29 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 32.54 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 3.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 15.39 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 1654.31 24.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 163.26 0.00



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

AirTerminal:SingleDuct:ConstantVolume:NoReheat

Design Size Maximum Air Flow Rate [m3/s]
BASEMENT DIRECT AIR 4.95
DATACENTER_BOT_ZN_6 DIRECT AIR 0.473781
DATACENTER_MID_ZN_6 DIRECT AIR 4.50
DATACENTER_TOP_ZN_6 DIRECT AIR 0.457306
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirTerminal:SingleDuct:VAV:Reheat

Design Size Maximum Air Flow Rate [m3/s] Design Size Constant Minimum Air Flow Fraction User-Specified Constant Minimum Air Flow Fraction Design Size Minimum Air Flow Rate [m3/s] Design Size Maximum Flow Fraction during Reheat [] User-Specified Maximum Flow Fraction during Reheat [] Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] Design Size Maximum Reheat Water Flow Rate [m3/s] Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] Design Size Reheat Coil Sizing Inlet Air Temperature [C] Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir]
CORE_BOTTOM VAV BOX COMPONENT 5.41 0.351697 0.346000 1.87 0.937859 0.500000 0.001083 0.000159 1.87 12.80 0.008000
CORE_MID VAV BOX COMPONENT 50.79 0.374515 0.359000 18.23 0.998707 0.500000 0.001017 0.003657 18.23 12.80 0.008000
CORE_TOP VAV BOX COMPONENT 5.04 0.377426 0.370000 1.86 1.00 0.500000 0.001009 0.000730 2.58 12.80 0.008000
PERIMETER_BOT_ZN_3 VAV BOX COMPONENT 0.873138 0.273520 0.269000 0.234874 0.729387 0.500000 0.001393 0.000097 0.341672 12.80 0.008000
PERIMETER_BOT_ZN_2 VAV BOX COMPONENT 0.878522 0.175186 0.200000 0.175704 0.467164 0.500000 0.002175 0.000067 0.238007 12.80 0.008000
PERIMETER_BOT_ZN_1 VAV BOX COMPONENT 1.02 0.234457 0.230000 0.234286 0.625218 0.500000 0.001625 0.000114 0.402196 12.80 0.008000
PERIMETER_BOT_ZN_4 VAV BOX COMPONENT 1.15 0.134094 0.200000 0.229548 0.357585 0.500000 0.002841 0.000053 0.229548 12.80 0.008000
PERIMETER_MID_ZN_3 VAV BOX COMPONENT 8.15 0.292984 0.281000 2.29 0.781291 0.500000 0.001300 0.001718 6.07 12.80 0.008000
PERIMETER_MID_ZN_2 VAV BOX COMPONENT 9.04 0.170300 0.200000 1.81 0.454133 0.500000 0.002237 0.001127 3.98 12.80 0.008000
PERIMETER_MID_ZN_1 VAV BOX COMPONENT 9.46 0.252413 0.242000 2.29 0.673101 0.500000 0.001509 0.001698 6.00 12.80 0.008000
PERIMETER_MID_ZN_4 VAV BOX COMPONENT 9.52 0.161719 0.200000 1.90 0.431252 0.500000 0.002356 0.001074 3.80 12.80 0.008000
PERIMETER_TOP_ZN_3 VAV BOX COMPONENT 0.933212 0.255912 0.251000 0.234236 0.682433 0.500000 0.001489 0.000227 0.803344 12.80 0.008000
PERIMETER_TOP_ZN_2 VAV BOX COMPONENT 0.926908 0.166041 0.200000 0.185382 0.442777 0.500000 0.002295 0.000148 0.524104 12.80 0.008000
PERIMETER_TOP_ZN_1 VAV BOX COMPONENT 1.07 0.224009 0.220000 0.234552 0.597357 0.500000 0.001701 0.000225 0.794702 12.80 0.008000
PERIMETER_TOP_ZN_4 VAV BOX COMPONENT 1.04 0.148089 0.200000 0.207855 0.394904 0.500000 0.002573 0.000145 0.512101 12.80 0.008000
User-Specified values were used. Design Size values were used if no User-Specified values were provided. Design Size values may be derived from alternate User-Specified values.

Coil:Heating:Water

Design Size Rated Capacity [W] Design Size Maximum Water Flow Rate [m3/s] Design Size U-Factor Times Area Value [W/K]
CORE_BOTTOM VAV BOX REHEAT COIL 18165.30 0.000159 366.20
CORE_MID VAV BOX REHEAT COIL 418017.04 0.003657 9750.67
CORE_TOP VAV BOX REHEAT COIL 83477.02 0.000730 2203.93
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL 11065.20 0.000097 292.07
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL 7705.64 0.000067 203.37
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL 13018.23 0.000114 343.54
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL 6029.76 0.000053 146.62
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL 196410.77 0.001718 5180.58
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL 128817.45 0.001127 3397.66
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL 194062.32 0.001698 5118.70
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL 122814.77 0.001074 3239.48
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL 25960.82 0.000227 684.58
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL 16936.53 0.000148 446.61
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL 25682.01 0.000225 677.24
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL 16549.16 0.000145 436.40
VAV_BOT WITH REHEAT HEATING COIL 56676.84 0.000496 919.09
VAV_MID WITH REHEAT HEATING COIL 534071.93 0.004672 8644.99
VAV_TOP WITH REHEAT HEATING COIL 56240.19 0.000492 912.07
CAV_BAS HEATING COIL 239673.49 0.002097 5305.82
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

ZoneHVAC:IdealLoadsAirSystem

Design Size Maximum Heating Air Flow Rate [m3/s] Design Size Maximum Cooling Air Flow Rate [m3/s]
AIRLOOP DATACENTER BASEMENT 0.338402 21.96
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC

Sum of Air Terminal Maximum Heating Flow Rates [m3/s] Sum of Air Terminal Minimum Heating Flow Rates [m3/s] Sum of Air Terminal Maximum Flow Rates [m3/s] Adjusted Heating Design Air Flow Rate [m3/s] Adjusted Cooling Design Air Flow Rate [m3/s] Adjusted Main Design Air Flow Rate [m3/s] User Heating Air Flow Ratio [] Calculated Heating Air Flow Ratio [] Design Supply Air Flow Rate [m3/s]
VAV_BOT WITH REHEAT 4.66 2.75 9.33 2.75 8.63 8.63 0.300000 0.318109 8.63
VAV_MID WITH REHEAT 43.48 26.52 86.95 30.64 79.89 79.89 0.300000 0.383468 79.89
VAV_TOP WITH REHEAT 4.50 2.73 9.01 5.21 8.57 8.57 0.300000 0.607934 8.57
CAV_BAS 4.95 4.95 4.95 4.95 4.95 4.95 1.00 1.00 4.95
AIRLOOP DATACENTER BOT 0.473781 0.473781 0.473781 0.473781 0.473781 0.473781 1.00 1.00 0.473781
AIRLOOP DATACENTER MID 4.50 4.50 4.50 4.50 4.50 4.50 1.00 1.00 4.50
AIRLOOP DATACENTER TOP 0.457306 0.457306 0.457306 0.457306 0.457306 0.457306 1.00 1.00 0.457306
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
VAV_BOT WITH REHEAT_OA_CONTROLLER 8.63  
VAV_MID WITH REHEAT_OA_CONTROLLER 79.89  
VAV_TOP WITH REHEAT_OA_CONTROLLER 8.57  
CAV_BAS_OA_CONTROLLER 4.95  
AIRLOOP DATACENTER BOT_OA_CONTROLLER 0.473781 0.015633
AIRLOOP DATACENTER MID_OA_CONTROLLER 4.50 0.156328
AIRLOOP DATACENTER TOP_OA_CONTROLLER 0.457306 0.015633
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

HeatExchanger:AirToAir:SensibleAndLatent

Design Size Nominal Supply Air Flow Rate [m3/s]
VAV_BOT WITH REHEAT OA HEAT RECOVERY 2.54
VAV_MID WITH REHEAT OA HEAT RECOVERY 25.38
VAV_TOP WITH REHEAT OA HEAT RECOVERY 2.54
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Cooling:Water

Design Size Design Inlet Air Temperature [C] Design Size Design Inlet Water Temperature [C] Design Size Design Outlet Air Temperature [C] Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] Design Size Design Coil Load [W] Design Size Design Water Flow Rate [m3/s] Design Size Design Air Flow Rate [m3/s]
VAV_BOT WITH REHEAT COOLING COIL 27.24 6.67 10.88 0.010643 0.008500 222106.69 0.009449 8.63
VAV_MID WITH REHEAT COOLING COIL 27.66 6.67 10.88 0.010916 0.008500 2160566.93 0.091916 79.89
VAV_TOP WITH REHEAT COOLING COIL 27.10 6.67 10.88 0.010573 0.008500 217377.98 0.009248 8.57
CAV_BAS COOLING COIL 26.47 6.67 11.37 0.010531 0.008500 118266.12 0.005031 4.95
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Fan:VariableVolume

Design Size Maximum Flow Rate [m3/s]
VAV_BOT WITH REHEAT FAN 8.63
VAV_MID WITH REHEAT FAN 79.89
VAV_TOP WITH REHEAT FAN 8.57
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Controller:WaterCoil

Maximum Actuated Flow [m3/s] Controller Convergence Tolerance
VAV_BOT WITH REHEAT_COOLC_CONTROLLER 0.009449 0.000050
VAV_BOT WITH REHEAT_HEATC_CONTROLLER 0.000496  
VAV_MID WITH REHEAT_COOLC_CONTROLLER 0.091916 0.000005
VAV_MID WITH REHEAT_HEATC_CONTROLLER 0.004672  
VAV_TOP WITH REHEAT_COOLC_CONTROLLER 0.009248 0.000051
VAV_TOP WITH REHEAT_HEATC_CONTROLLER 0.000492  
CAV_BAS_COOLC_CONTROLLER 0.005031 0.000095
CAV_BAS_HEATC_CONTROLLER 0.002097  
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Fan:ConstantVolume

Design Size Maximum Flow Rate [m3/s]
CAV_BAS FAN 4.95
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT

Design Size Rated Air Flow Rate [m3/s] Design Size Rated Total Cooling Capacity [W] Design Size Rated Sensible Cooling Capacity [W] Design Size Rated Water Flow Rate [m3/s]
AIRLOOP DATACENTER BOT COOLING COIL 0.473781 9347.24 6482.34 0.000229
AIRLOOP DATACENTER MID COOLING COIL 4.50 89037.51 61684.77 0.002181
AIRLOOP DATACENTER TOP COOLING COIL 0.457306 9033.64 6260.53 0.000221
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC:UnitaryHeatPump:WaterToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
AIRLOOP DATACENTER BOT DXAC HEAT PUMP 0.473781 0.473781 0.473781 0.473781 9347.24 9347.24 844.40 1.00
AIRLOOP DATACENTER MID DXAC HEAT PUMP 4.50 4.50 4.50 4.50 89037.51 89037.51 8443.96 1.00
AIRLOOP DATACENTER TOP DXAC HEAT PUMP 0.457306 0.457306 0.457306 0.457306 9033.64 9033.64 844.40 1.00
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Fan:OnOff

Design Size Maximum Flow Rate [m3/s]
AIRLOOP DATACENTER BOT SUPPLY FAN 0.473781
AIRLOOP DATACENTER MID SUPPLY FAN 4.50
AIRLOOP DATACENTER TOP SUPPLY FAN 0.457306
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT

Design Size Rated Air Flow Rate [m3/s] Design Size Rated Heating Capacity [W] Design Size Rated Water Flow Rate [m3/s]
AIRLOOP DATACENTER BOT HEATING COIL 0.473781 9347.24 0.000229
AIRLOOP DATACENTER MID HEATING COIL 4.50 89037.51 0.002181
AIRLOOP DATACENTER TOP HEATING COIL 0.457306 9033.64 0.000221
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Heating:Electric

Design Size Nominal Capacity [W]
AIRLOOP DATACENTER BOT_SUPPHEATCOIL 844.40
AIRLOOP DATACENTER MID_SUPPHEATCOIL 8443.96
AIRLOOP DATACENTER TOP_SUPPHEATCOIL 844.40
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Pump:VariableSpeed

Design Flow Rate [m3/s] Design Power Consumption [W] Design Minimum Flow Rate [m3/s]
COOLSYS1 PUMP SECONDARY 0.115644 23593.90  
HEATSYS1 PUMP 0.018996 5664.16 0.000000
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
COOLSYS1_DEMAND 0.115644 13.88
HEATSYS1 0.018996 2.28
COOLSYS1_SUPPLY 0.115644 13.88
SINGLE WATER PLANT LOOP 0.002631 0.315680
SWHSYS1 0.000440 0.052800
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

HeatExchanger:FluidToFluid

Loop Supply Side Design Fluid Flow Rate [m3/s] Loop Demand Side Design Fluid Flow Rate [m3/s] Heat Exchanger U-Factor Times Area Value [W/C] Loop-to-loop Temperature Difference Used to Size Heat Exchanger U-Factor Times Area Value [C]
BYPASS HEAT EXCHANGER 0.115644 0.115644 485413.88 5.60
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Boiler:HotWater

Design Size Nominal Capacity [W] User-Specified Nominal Capacity [W] Design Size Design Water Flow Rate [m3/s]
HEATSYS1 BOILER 2171374.48 2171374.48 0.018996
CENTRAL BOILER 108361.02 108361.02 0.002631
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Pump:ConstantSpeed

Design Flow Rate [m3/s] Design Power Consumption [W]
COOLSYS1 PUMP 0.115644 16334.86
PLANT CIRC PUMP 0.002631 664.31
SWHSYS1 PUMP 0.000440 5.96
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Chiller:Electric:ReformulatedEIR

Design Size Reference Chilled Water Flow Rate [m3/s] User-Specified Reference Chilled Water Flow Rate [m3/s] Design Size Reference Capacity [W] User-Specified Reference Capacity [W] Design Size Reference Condenser Water Flow Rate [m3/s]
COOLSYS1 CHILLER1 0.115644 0.058070 1368347.06 1374850.56 0.068036
COOLSYS1 CHILLER2 0.115644 0.058070 1368347.06 1374850.56 0.068036
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

FluidCooler:TwoSpeed

Design Water Flow Rate [m3/s] Air Flow Rate at High Fan Speed [m3/s] Fluid cooler UA value at high fan speed based on nominal capacity input [W/K] Air Flow Rate at Low Fan Speed [m3/s] Fan Power at Low Fan Speed [W] U-factor Times Area Value at Low Fan Speed [W/C]
CENTRAL TOWER 0.002631 35644.39 22092.84 17822.20 1996.20 5895.73
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

WaterHeater:Mixed

Use Side Design Flow Rate [m3/s]
SWHSYS1 WATER HEATER 0.000440
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

CondenserLoop

Maximum Loop Flow Rate [m3/s] Condenser Loop Volume [m3]
TOWERWATERSYS 0.136073 16.33
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

HeaderedPumps:VariableSpeed

Design Flow Rate [m3/s] Design Power Consumption [W]
TOWERWATERSYS PUMP 0.136073 40576.32
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

CoolingTower:VariableSpeed

Design Air Flow Rate [m3/s] Nominal Capacity [W] Air Flow Rate in free convection regime [m3/s] Tower capacity in free convection regime at design conditions [W]
TOWERWATERSYS COOLTOWER 1 54.54 1631210.05 10.91 203901.26
TOWERWATERSYS COOLTOWER 2 54.54 1631210.05 10.91 203901.26
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

PlantEquipmentOperation:ComponentSetPoint

Design Water Flow Rate [m3/s] Equipment # 45
WSHPPLANT OPERATION SCHEME 0.070667
User-Specified values were used. Design Size values were used if no User-Specified values were provided.


Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
PERIMETER_BOT_ZN_3_WALL_NORTH PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR3 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR4 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 |
PERIMETER_BOT_ZN_2_WALL_EAST PERIMETER_BOT_ZN_2_WALL_EAST_DOOR1 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 |
PERIMETER_BOT_ZN_1_WALL_SOUTH PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR3 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR4 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 |
PERIMETER_BOT_ZN_4_WALL_WEST PERIMETER_BOT_ZN_4_WALL_WEST_DOOR1 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR2 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 |
PERIMETER_MID_ZN_3_WALL_NORTH PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW |
PERIMETER_MID_ZN_2_WALL_EAST PERIMETER_MID_ZN_2_WALL_EAST_WINDOW |
PERIMETER_MID_ZN_1_WALL_SOUTH PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW |
PERIMETER_MID_ZN_4_WALL_WEST PERIMETER_MID_ZN_4_WALL_WEST_WINDOW |
PERIMETER_TOP_ZN_3_WALL_NORTH PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW |
PERIMETER_TOP_ZN_2_WALL_EAST PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW |
PERIMETER_TOP_ZN_1_WALL_SOUTH PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW |
PERIMETER_TOP_ZN_4_WALL_WEST PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: Initialization Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Version

Version ID
1 22.1.0


Timesteps per Hour

#TimeSteps Minutes per TimeStep {minutes}
1 6 10


System Convergence Limits

Minimum System TimeStep {minutes} Max HVAC Iterations Minimum Plant Iterations Maximum Plant Iterations
1 1 20 2 8


Simulation Control

Do Zone Sizing Do System Sizing Do Plant Sizing Do Design Days Do Weather Simulation Do HVAC Sizing Simulation
1 Yes Yes Yes No Yes No


Performance Precision Tradeoffs

Use Coil Direct Simulation Zone Radiant Exchange Algorithm Override Mode Number of Timestep In Hour Force Euler Method Minimum Number of Warmup Days Force Suppress All Begin Environment Resets Minimum System Timestep MaxZoneTempDiff MaxAllowedDelTemp
1 No ScriptF Normal 6 No 1 No 1.0 0.300 2.0000E-003


Output Reporting Tolerances

Tolerance for Time Heating Setpoint Not Met Tolerance for Zone Cooling Setpoint Not Met Time
1 0.556 0.556


Site:GroundTemperature:BuildingSurface

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00


Site:GroundTemperature:FCfactorMethod

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 16.00 11.90 7.70 4.00 7.90 13.80 17.20 20.80 24.80 26.10 26.50 22.50


Site:GroundTemperature:Shallow

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00


Site:GroundTemperature:Deep

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00


Site:GroundReflectance

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Site:GroundReflectance:SnowModifier

Normal Daylighting {dimensionless}
1 1.000 1.000


Site:GroundReflectance:Snow

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Site:GroundReflectance:Snow:Daylighting

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Environment:Weather Station

Wind Sensor Height Above Ground {m} Wind Speed Profile Exponent {} Wind Speed Profile Boundary Layer Thickness {m} Air Temperature Sensor Height Above Ground {m} Wind Speed Modifier Coefficient-Internal Temperature Modifier Coefficient-Internal
1 10.000 0.140 270.000 1.500 1.586 9.750E-003


Site:Location

Location Name Latitude {N+/S- Deg} Longitude {E+/W- Deg} Time Zone Number {GMT+/-} Elevation {m} Standard Pressure at Elevation {Pa} Standard RhoAir at Elevation
1 Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190 33.63 -84.43 -5.00 308.00 97679 1.1610


Site Water Mains Temperature Information

Calculation Method{} Water Mains Temperature Schedule Name{} Annual Average Outdoor Air Temperature{C} Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} Fixed Default Water Mains Temperature{C}
1 Correlation NA 16.60 22.50 NA


Building Information

Building Name North Axis {deg} Terrain Loads Convergence Tolerance Value Temperature Convergence Tolerance Value Solar Distribution Maximum Number of Warmup Days Minimum Number of Warmup Days
1 OfficeLarge 0.000 City 4.00000E-002 0.20000 FullInteriorAndExterior 25 6


Inside Convection Algorithm

Algorithm {Simple
TARP
CeilingDiffuser
AdaptiveConvectionAlgorithm}
1 TARP


Outside Convection Algorithm

Algorithm {SimpleCombined
TARP
MoWitt
DOE-2
AdaptiveConvectionAlgorithm}
1 TARP


Sky Radiance Distribution

Value {Anisotropic}
1 Anisotropic


Zone Air Solution Algorithm

Value {ThirdOrderBackwardDifference
AnalyticalSolution
EulerMethod}
1 ThirdOrderBackwardDifference


Zone Air Carbon Dioxide Balance Simulation

Simulation {Yes/No} Carbon Dioxide Concentration
1 No N/A


Zone Air Generic Contaminant Balance Simulation

Simulation {Yes/No} Generic Contaminant Concentration
1 No N/A


Zone Air Mass Flow Balance Simulation

Enforce Mass Balance



Adjust Zone Mixing and Return {AdjustMixingOnly
AdjustReturnOnly
AdjustMixingThenReturn
AdjustReturnThenMixing
None}
Adjust Zone Infiltration {AddInfiltration
AdjustInfiltration
None}

Infiltration Zones {MixingSourceZonesOnly
AllZones}


1 No N/A N/A N/A


HVACSystemRootFindingAlgorithm

Value {RegulaFalsi
Bisection
BisectionThenRegulaFalsi
RegulaFalsiThenBisection}
1 RegulaFalsi


Environment:Site Atmospheric Variation

Wind Speed Profile Exponent {} Wind Speed Profile Boundary Layer Thickness {m} Air Temperature Gradient Coefficient {K/m}
1 0.330 460.000 6.500000E-003


Surface Geometry

Starting Corner Vertex Input Direction Coordinate System Daylight Reference Point Coordinate System Rectangular (Simple) Surface Coordinate System
1 UpperLeftCorner Counterclockwise RelativeCoordinateSystem RelativeCoordinateSystem RelativeToZoneOrigin


Surface Heat Transfer Algorithm

Value {CTF - ConductionTransferFunction
EMPD - MoisturePenetrationDepthConductionTransferFunction
CondFD - ConductionFiniteDifference
HAMT - CombinedHeatAndMoistureFiniteElement} - Description
Inside Surface Max Temperature Limit{C}


Surface Convection Coefficient Lower Limit {W/m2-K}


Surface Convection Coefficient Upper Limit {W/m2-K}


1 CTF - ConductionTransferFunction 200 0.10 1000.0


Shading Summary

Number of Fixed Detached Shades Number of Building Detached Shades Number of Attached Shades
1 0 0 0


Zone Summary

Number of Zones Number of Zone Surfaces Number of SubSurfaces
1 23 221 36


Zone Information

Zone Name North Axis {deg} Origin X-Coordinate {m} Origin Y-Coordinate {m} Origin Z-Coordinate {m} Centroid X-Coordinate {m} Centroid Y-Coordinate {m} Centroid Z-Coordinate {m} Type Zone Multiplier Zone List Multiplier Minimum X {m} Maximum X {m} Minimum Y {m} Maximum Y {m} Minimum Z {m} Maximum Z {m} Ceiling Height {m} Volume {m3} Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} Floor Area {m2} Exterior Gross Wall Area {m2} Exterior Net Wall Area {m2} Exterior Window Area {m2} Number of Surfaces Number of SubSurfaces Number of Shading SubSurfaces Part of Total Building Area
1 BASEMENT 0.0 0.00 0.00 0.00 44.59 24.37 -1.22 1 1 1 16.08 73.11 0.00 48.74 -2.44 0.00 2.44 6779.02 TARP TARP 2779.43 0.00 0.00 0.00 9 0 0 Yes
2 CORE_BOTTOM 0.0 0.00 0.00 0.00 37.01 24.37 1.37 1 1 1 5.49 68.53 4.57 44.17 0.00 2.74 2.74 6849.35 TARP TARP 2496.12 0.00 0.00 0.00 7 0 0 Yes
3 CORE_MID 0.0 0.00 0.00 0.00 37.01 24.37 18.14 1 10 1 5.49 68.53 4.57 44.17 16.77 19.51 2.74 6849.35 TARP TARP 2496.12 0.00 0.00 0.00 6 0 0 Yes
4 CORE_TOP 0.0 0.00 0.00 0.00 37.01 24.37 34.91 1 1 1 5.49 68.53 4.57 44.17 33.54 36.28 2.74 6849.35 TARP TARP 2496.12 0.00 0.00 0.00 6 0 0 Yes
5 PERIMETER_BOT_ZN_3 0.0 0.00 0.00 0.00 36.55 46.54 1.37 1 1 1 0.00 73.11 44.17 48.74 0.00 2.74 2.74 860.00 TARP TARP 313.41 200.61 105.88 86.92 8 9 0 Yes
6 PERIMETER_BOT_ZN_2 0.0 0.00 0.00 0.00 70.95 24.37 1.37 1 1 1 68.53 73.11 0.00 48.74 0.00 2.74 2.74 554.22 TARP TARP 201.98 133.74 71.89 57.95 6 5 0 Yes
7 PERIMETER_BOT_ZN_1 0.0 0.00 0.00 0.00 36.55 2.20 1.37 1 1 1 0.00 73.11 0.00 4.57 0.00 2.74 2.74 860.02 TARP TARP 313.42 200.61 105.88 86.92 8 9 0 Yes
8 PERIMETER_BOT_ZN_4 0.0 0.00 0.00 0.00 2.16 24.37 1.37 1 1 1 0.00 4.57 0.00 48.74 0.00 2.74 2.74 554.22 TARP TARP 201.98 133.74 71.89 57.95 6 5 0 Yes
9 PERIMETER_MID_ZN_3 0.0 0.00 0.00 0.00 36.55 46.54 18.14 1 10 1 0.00 73.11 44.17 48.74 16.77 19.51 2.74 860.00 TARP TARP 313.41 200.61 113.68 86.92 7 1 0 Yes
10 PERIMETER_MID_ZN_2 0.0 0.00 0.00 0.00 70.95 24.37 18.14 1 10 1 68.53 73.11 0.00 48.74 16.77 19.51 2.74 554.22 TARP TARP 201.98 133.74 75.79 57.95 6 1 0 Yes
11 PERIMETER_MID_ZN_1 0.0 0.00 0.00 0.00 36.55 2.20 18.14 1 10 1 0.00 73.11 0.00 4.57 16.77 19.51 2.74 860.02 TARP TARP 313.42 200.61 113.68 86.92 7 1 0 Yes
12 PERIMETER_MID_ZN_4 0.0 0.00 0.00 0.00 2.16 24.37 18.14 1 10 1 0.00 4.57 0.00 48.74 16.77 19.51 2.74 554.22 TARP TARP 201.98 133.74 75.79 57.95 6 1 0 Yes
13 PERIMETER_TOP_ZN_3 0.0 0.00 0.00 0.00 36.55 46.54 34.91 1 1 1 0.00 73.11 44.17 48.74 33.54 36.28 2.74 860.00 TARP TARP 313.41 200.61 113.68 86.92 7 1 0 Yes
14 PERIMETER_TOP_ZN_2 0.0 0.00 0.00 0.00 70.95 24.37 34.91 1 1 1 68.53 73.11 0.00 48.74 33.54 36.28 2.74 554.22 TARP TARP 201.98 133.74 75.79 57.95 6 1 0 Yes
15 PERIMETER_TOP_ZN_1 0.0 0.00 0.00 0.00 36.55 2.20 34.91 1 1 1 0.00 73.11 0.00 4.57 33.54 36.28 2.74 860.02 TARP TARP 313.42 200.61 113.68 86.92 7 1 0 Yes
16 PERIMETER_TOP_ZN_4 0.0 0.00 0.00 0.00 2.16 24.37 34.91 1 1 1 0.00 4.57 0.00 48.74 33.54 36.28 2.74 554.22 TARP TARP 201.98 133.74 75.79 57.95 6 1 0 Yes
17 GROUNDFLOOR_PLENUM 0.0 0.00 0.00 0.00 36.55 24.37 3.35 1 1 1 0.00 73.11 0.00 48.74 2.74 3.96 1.22 4344.14 TARP TARP 3563.11 297.11 297.11 0.00 11 0 0 No
18 MIDFLOOR_PLENUM 0.0 0.00 0.00 0.00 36.55 24.37 20.12 1 10 1 0.00 73.11 0.00 48.74 19.51 20.73 1.22 4344.14 TARP TARP 3563.11 297.11 297.11 0.00 11 0 0 No
19 TOPFLOOR_PLENUM 0.0 0.00 0.00 0.00 36.55 24.37 36.89 1 1 1 0.00 73.11 0.00 48.74 36.28 37.50 1.22 4344.14 TARP TARP 3563.11 297.11 297.11 0.00 11 0 0 No
20 DATACENTER_BOT_ZN_6 0.0 5.49 44.17 0.00 5.03 24.37 1.37 1 1 1 4.57 5.49 4.57 44.17 0.00 2.74 2.74 99.34 TARP TARP 36.20 0.00 0.00 0.00 6 0 0 Yes
21 DATACENTER_MID_ZN_6 0.0 4.57 4.57 16.77 5.03 24.37 18.14 1 10 1 4.57 5.49 4.57 44.17 16.77 19.51 2.74 99.34 TARP TARP 36.20 0.00 0.00 0.00 6 0 0 Yes
22 DATACENTER_TOP_ZN_6 0.0 4.57 4.57 33.54 5.03 24.37 34.91 1 1 1 4.57 5.49 4.57 44.17 33.54 36.28 2.74 99.34 TARP TARP 36.20 0.00 0.00 0.00 6 0 0 Yes
23 DATACENTER_BASEMENT_ZN_6 0.0 16.08 0.00 -2.44 8.04 24.37 -1.22 1 1 1 0.00 16.08 0.00 48.74 -2.44 0.00 2.44 1911.37 TARP TARP 783.68 0.00 0.00 0.00 10 0 0 Yes


Zone Internal Gains Nominal

Zone Name Floor Area {m2} # Occupants Area per Occupant {m2/person} Occupant per Area {person/m2} Interior Lighting {W/m2} Electric Load {W/m2} Gas Load {W/m2} Other Load {W/m2} Hot Water Eq {W/m2} Steam Equipment {W/m2} Sum Loads per Area {W/m2} Outdoor Controlled Baseboard Heat
1 BASEMENT 2779.43 149.6 18.579 5.382E-002 5.889 4.842 0.000 0.000 0.000 0.000 10.731 No
2 CORE_BOTTOM 2496.12 134.4 18.579 5.382E-002 5.889 8.070 0.000 0.000 0.000 0.000 13.959 No
3 CORE_MID 2496.12 134.4 18.579 5.382E-002 5.889 8.070 0.000 0.000 0.000 0.000 13.959 No
4 CORE_TOP 2496.12 134.4 18.579 5.382E-002 5.889 8.070 0.000 0.000 0.000 0.000 13.959 No
5 PERIMETER_BOT_ZN_3 313.41 16.9 18.579 5.382E-002 5.889 8.070 0.000 0.000 0.000 0.000 13.959 No
6 PERIMETER_BOT_ZN_2 201.98 10.9 18.579 5.382E-002 5.889 8.070 0.000 0.000 0.000 0.000 13.959 No
7 PERIMETER_BOT_ZN_1 313.42 16.9 18.579 5.382E-002 5.889 8.070 0.000 0.000 0.000 0.000 13.959 No
8 PERIMETER_BOT_ZN_4 201.98 10.9 18.579 5.382E-002 5.889 8.070 0.000 0.000 0.000 0.000 13.959 No
9 PERIMETER_MID_ZN_3 313.41 16.9 18.579 5.382E-002 5.889 8.070 0.000 0.000 0.000 0.000 13.959 No
10 PERIMETER_MID_ZN_2 201.98 10.9 18.579 5.382E-002 5.889 8.070 0.000 0.000 0.000 0.000 13.959 No
11 PERIMETER_MID_ZN_1 313.42 16.9 18.579 5.382E-002 5.889 8.070 0.000 0.000 0.000 0.000 13.959 No
12 PERIMETER_MID_ZN_4 201.98 10.9 18.579 5.382E-002 5.889 8.070 0.000 0.000 0.000 0.000 13.959 No
13 PERIMETER_TOP_ZN_3 313.41 16.9 18.579 5.382E-002 5.889 8.070 0.000 0.000 0.000 0.000 13.959 No
14 PERIMETER_TOP_ZN_2 201.98 10.9 18.579 5.382E-002 5.889 8.070 0.000 0.000 0.000 0.000 13.959 No
15 PERIMETER_TOP_ZN_1 313.42 16.9 18.579 5.382E-002 5.889 8.070 0.000 0.000 0.000 0.000 13.959 No
16 PERIMETER_TOP_ZN_4 201.98 10.9 18.579 5.382E-002 5.889 8.070 0.000 0.000 0.000 0.000 13.959 No
17 GROUNDFLOOR_PLENUM 3563.11 0.0 N/A 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 No
18 MIDFLOOR_PLENUM 3563.11 0.0 N/A 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 No
19 TOPFLOOR_PLENUM 3563.11 0.0 N/A 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 No
20 DATACENTER_BOT_ZN_6 36.20 1.9 18.579 5.382E-002 8.801 215.299 0.000 0.000 0.000 0.000 224.100 No
21 DATACENTER_MID_ZN_6 36.20 1.9 18.579 5.382E-002 8.801 215.299 0.000 0.000 0.000 0.000 224.100 No
22 DATACENTER_TOP_ZN_6 36.20 1.9 18.579 5.382E-002 8.801 215.299 0.000 0.000 0.000 0.000 224.100 No
23 DATACENTER_BASEMENT_ZN_6 783.68 42.2 18.579 5.382E-002 5.889 484.423 0.000 0.000 0.000 0.000 490.313 No


People Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Number of People {} People/Floor Area {person/m2} Floor Area per person {m2/person} Fraction Radiant Fraction Convected Sensible Fraction Calculation Activity level ASHRAE 55 Warnings Carbon Dioxide Generation Rate Nominal Minimum Number of People Nominal Maximum Number of People MRT Calculation Type Work Efficiency Clothing Insulation Calculation Method Clothing Insulation Calculation Method Schedule Clothing Air Velocity Fanger Calculation Pierce Calculation KSU Calculation Cooling Effect Calculation Ankle Draft Calculation
1 DATACENTER_BOT_ZN_6 BLDG_OCC_SCH_WO_SB DATACENTER_BOT_ZN_6 36.20 1.9 1.9 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 2 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
2 DATACENTER_MID_ZN_6 BLDG_OCC_SCH_WO_SB DATACENTER_MID_ZN_6 36.20 1.9 1.9 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 2 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
3 DATACENTER_TOP_ZN_6 BLDG_OCC_SCH_WO_SB DATACENTER_TOP_ZN_6 36.20 1.9 1.9 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 2 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
4 DATACENTER_BASEMENT_ZN_6 BLDG_OCC_SCH_WO_SB DATACENTER_BASEMENT_ZN_6 783.68 42.2 42.2 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 42 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
5 BASEMENT BLDG_OCC_SCH_WO_SB BASEMENT 2779.43 149.6 149.6 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 150 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
6 CORE_BOTTOM BLDG_OCC_SCH_WO_SB CORE_BOTTOM 2496.12 134.4 134.4 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 134 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
7 CORE_MID BLDG_OCC_SCH_WO_SB CORE_MID 2496.12 134.4 134.4 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 134 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
8 CORE_TOP BLDG_OCC_SCH_WO_SB CORE_TOP 2496.12 134.4 134.4 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 134 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
9 PERIMETER_BOT_ZN_3 BLDG_OCC_SCH_WO_SB PERIMETER_BOT_ZN_3 313.41 16.9 16.9 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 17 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
10 PERIMETER_BOT_ZN_2 BLDG_OCC_SCH_WO_SB PERIMETER_BOT_ZN_2 201.98 10.9 10.9 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 11 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
11 PERIMETER_BOT_ZN_1 BLDG_OCC_SCH_WO_SB PERIMETER_BOT_ZN_1 313.42 16.9 16.9 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 17 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
12 PERIMETER_BOT_ZN_4 BLDG_OCC_SCH_WO_SB PERIMETER_BOT_ZN_4 201.98 10.9 10.9 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 11 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
13 PERIMETER_MID_ZN_3 BLDG_OCC_SCH_WO_SB PERIMETER_MID_ZN_3 313.41 16.9 16.9 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 17 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
14 PERIMETER_MID_ZN_2 BLDG_OCC_SCH_W_SB PERIMETER_MID_ZN_2 201.98 10.9 10.9 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 11 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
15 PERIMETER_MID_ZN_1 BLDG_OCC_SCH_WO_SB PERIMETER_MID_ZN_1 313.42 16.9 16.9 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 17 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
16 PERIMETER_MID_ZN_4 BLDG_OCC_SCH_WO_SB PERIMETER_MID_ZN_4 201.98 10.9 10.9 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 11 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
17 PERIMETER_TOP_ZN_3 BLDG_OCC_SCH_WO_SB PERIMETER_TOP_ZN_3 313.41 16.9 16.9 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 17 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
18 PERIMETER_TOP_ZN_2 BLDG_OCC_SCH_WO_SB PERIMETER_TOP_ZN_2 201.98 10.9 10.9 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 11 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
19 PERIMETER_TOP_ZN_1 BLDG_OCC_SCH_WO_SB PERIMETER_TOP_ZN_1 313.42 16.9 16.9 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 17 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No
20 PERIMETER_TOP_ZN_4 BLDG_OCC_SCH_WO_SB PERIMETER_TOP_ZN_4 201.98 10.9 10.9 5.382E-002 18.579 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 11 Zone Averaged WORK_EFF_SCH Clothing Insulation Schedule N/A CLOTHING_SCH AIR_VELO_SCH Yes No No No No


Lights Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Lighting Level {W} Lights/Floor Area {W/m2} Lights per person {W/person} Fraction Return Air Fraction Radiant Fraction Short Wave Fraction Convected Fraction Replaceable End-Use Category Nominal Minimum Lighting Level {W} Nominal Maximum Lighting Level {W}
1 BASEMENT_LIGHTS LTG_SCH_OFFICE BASEMENT 2779.43 149.6 16369.361 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 16369.361
2 CORE_BOTTOM_LIGHTS LTG_SCH_OFFICE CORE_BOTTOM 2496.12 134.4 14700.837 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 14700.837
3 CORE_MID_LIGHTS LTG_SCH_OFFICE CORE_MID 2496.12 134.4 14700.837 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 14700.837
4 CORE_TOP_LIGHTS LTG_SCH_OFFICE CORE_TOP 2496.12 134.4 14700.837 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 14700.837
5 PERIMETER_BOT_ZN_3_LIGHTS LTG_SCH_OFFICE PERIMETER_BOT_ZN_3 313.41 16.9 1845.837 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1845.837
6 PERIMETER_BOT_ZN_2_LIGHTS LTG_SCH_OFFICE PERIMETER_BOT_ZN_2 201.98 10.9 1189.527 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1189.527
7 PERIMETER_BOT_ZN_1_LIGHTS LTG_SCH_OFFICE PERIMETER_BOT_ZN_1 313.42 16.9 1845.877 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1845.877
8 PERIMETER_BOT_ZN_4_LIGHTS LTG_SCH_OFFICE PERIMETER_BOT_ZN_4 201.98 10.9 1189.527 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1189.527
9 PERIMETER_MID_ZN_3_LIGHTS LTG_SCH_OFFICE PERIMETER_MID_ZN_3 313.41 16.9 1845.837 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1845.837
10 PERIMETER_MID_ZN_2_LIGHTS LTG_SCH_OFFICE PERIMETER_MID_ZN_2 201.98 10.9 1189.527 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1189.527
11 PERIMETER_MID_ZN_1_LIGHTS LTG_SCH_OFFICE PERIMETER_MID_ZN_1 313.42 16.9 1845.877 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1845.877
12 PERIMETER_MID_ZN_4_LIGHTS LTG_SCH_OFFICE PERIMETER_MID_ZN_4 201.98 10.9 1189.527 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1189.527
13 PERIMETER_TOP_ZN_3_LIGHTS LTG_SCH_OFFICE PERIMETER_TOP_ZN_3 313.41 16.9 1845.837 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1845.837
14 PERIMETER_TOP_ZN_2_LIGHTS LTG_SCH_OFFICE PERIMETER_TOP_ZN_2 201.98 10.9 1189.527 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1189.527
15 PERIMETER_TOP_ZN_1_LIGHTS LTG_SCH_OFFICE PERIMETER_TOP_ZN_1 313.42 16.9 1845.877 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1845.877
16 PERIMETER_TOP_ZN_4_LIGHTS LTG_SCH_OFFICE PERIMETER_TOP_ZN_4 201.98 10.9 1189.527 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1189.527
17 DATACENTER_BASEMENT_LIGHTS LTG_SCH_OFFICE DATACENTER_BASEMENT_ZN_6 783.68 42.2 4615.459 5.889 109.419 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 4615.459
18 DATACENTER_BOT_LIGHTS LTG_SCH_DATACENTER DATACENTER_BOT_ZN_6 36.20 1.9 318.624 8.801 163.514 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 318.624
19 DATACENTER_MID_LIGHTS LTG_SCH_DATACENTER DATACENTER_MID_ZN_6 36.20 1.9 318.624 8.801 163.514 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 318.624
20 DATACENTER_TOP_LIGHTS LTG_SCH_DATACENTER DATACENTER_TOP_ZN_6 36.20 1.9 318.624 8.801 163.514 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 318.624


ElectricEquipment Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Equipment Level {W} Equipment/Floor Area {W/m2} Equipment per person {W/person} Fraction Latent Fraction Radiant Fraction Lost Fraction Convected End-Use SubCategory Nominal Minimum Equipment Level {W} Nominal Maximum Equipment Level {W}
1 BASEMENT_MISCPLUG_EQUIP ALWAYS_ON BASEMENT 2779.43 149.6 13457.544 4.842 89.956 0.000 0.500 0.000 0.500 MiscPlug 13457.544 13457.544
2 CORE_BOTTOM_MISCPLUG_EQUIP BLDG_EQUIP_SCH CORE_BOTTOM 2496.12 134.4 20142.877 8.070 149.925 0.000 0.500 0.000 0.500 MiscPlug 0.000 20142.877
3 CORE_MID_MISCPLUG_EQUIP BLDG_EQUIP_SCH CORE_MID 2496.12 134.4 20142.800 8.070 149.924 0.000 0.500 0.000 0.500 MiscPlug 0.000 20142.800
4 CORE_TOP_MISCPLUG_EQUIP BLDG_EQUIP_SCH CORE_TOP 2496.12 134.4 20142.800 8.070 149.924 0.000 0.500 0.000 0.500 MiscPlug 0.000 20142.800
5 PERIMETER_BOT_ZN_3_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_BOT_ZN_3 313.41 16.9 2529.242 8.070 149.931 0.000 0.500 0.000 0.500 MiscPlug 0.000 2529.242
6 PERIMETER_BOT_ZN_2_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_BOT_ZN_2 201.98 10.9 1629.940 8.070 149.931 0.000 0.500 0.000 0.500 MiscPlug 0.000 1629.940
7 PERIMETER_BOT_ZN_1_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_BOT_ZN_1 313.42 16.9 2529.281 8.070 149.930 0.000 0.500 0.000 0.500 MiscPlug 0.000 2529.281
8 PERIMETER_BOT_ZN_4_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_BOT_ZN_4 201.98 10.9 1629.929 8.070 149.930 0.000 0.500 0.000 0.500 MiscPlug 0.000 1629.929
9 PERIMETER_MID_ZN_3_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_MID_ZN_3 313.41 16.9 2529.242 8.070 149.931 0.000 0.500 0.000 0.500 MiscPlug 0.000 2529.242
10 PERIMETER_MID_ZN_2_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_MID_ZN_2 201.98 10.9 1629.940 8.070 149.931 0.000 0.500 0.000 0.500 MiscPlug 0.000 1629.940
11 PERIMETER_MID_ZN_1_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_MID_ZN_1 313.42 16.9 2529.281 8.070 149.930 0.000 0.500 0.000 0.500 MiscPlug 0.000 2529.281
12 PERIMETER_MID_ZN_4_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_MID_ZN_4 201.98 10.9 1629.929 8.070 149.930 0.000 0.500 0.000 0.500 MiscPlug 0.000 1629.929
13 PERIMETER_TOP_ZN_3_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_TOP_ZN_3 313.41 16.9 2529.242 8.070 149.931 0.000 0.500 0.000 0.500 MiscPlug 0.000 2529.242
14 PERIMETER_TOP_ZN_2_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_TOP_ZN_2 201.98 10.9 1629.940 8.070 149.931 0.000 0.500 0.000 0.500 MiscPlug 0.000 1629.940
15 PERIMETER_TOP_ZN_1_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_TOP_ZN_1 313.42 16.9 2529.281 8.070 149.930 0.000 0.500 0.000 0.500 MiscPlug 0.000 2529.281
16 PERIMETER_TOP_ZN_4_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_TOP_ZN_4 201.98 10.9 1629.929 8.070 149.930 0.000 0.500 0.000 0.500 MiscPlug 0.000 1629.929
17 DATACENTER_BASEMENT_MISCPLUG_EQUIP DATACENTER_EQUIP_SCH DATACENTER_BASEMENT_ZN_6 783.68 42.2 379632.522 484.423 9000.000 0.000 0.100 0.000 0.900 DataCenterPlugLoads 94908.130 379632.522
18 DATACENTER_BOT_MISCPLUG_EQUIP DATACENTER_EQUIP_SCH DATACENTER_BOT_ZN_6 36.20 1.9 7794.422 215.299 4000.000 0.000 0.100 0.000 0.900 DataCenterPlugLoads 1948.606 7794.422
19 DATACENTER_MID_MISCPLUG_EQUIP DATACENTER_EQUIP_SCH DATACENTER_MID_ZN_6 36.20 1.9 7794.422 215.299 4000.000 0.000 0.100 0.000 0.900 DataCenterPlugLoads 1948.606 7794.422
20 DATACENTER_TOP_MISCPLUG_EQUIP DATACENTER_EQUIP_SCH DATACENTER_TOP_ZN_6 36.20 1.9 7794.422 215.299 4000.000 0.000 0.100 0.000 0.900 DataCenterPlugLoads 1948.606 7794.422


Construction CTF

Construction Name Index #Layers #CTFs Time Step {hours} ThermalConductance {w/m2-K} OuterThermalAbsorptance InnerThermalAbsorptance OuterSolarAbsorptance InnerSolarAbsorptance Roughness
1 SWINGING DOOR_CON 1 1 1 0.167 2.101 0.900 0.900 0.700 0.700 MediumRough
2 INTERIORFURNISHINGS 2 1 9 0.167 0.8000 0.900 0.900 0.700 0.700 MediumSmooth
3 DROPCEILING 4 1 3 0.167 4.488 0.900 0.900 0.700 0.700 MediumSmooth
4 INT_WALL 7 2 4 0.167 6.299 0.900 0.900 0.700 0.700 Smooth
5 EXT_SLAB_8IN_WITH_CARPET 8 2 7 0.167 3.285 0.900 0.900 0.700 0.700 MediumRough
6 INT_SLAB_FLOOR 12 2 7 0.167 3.839 0.900 0.900 0.700 0.700 MediumRough
7 INT_SLAB_CEILING 13 2 7 0.167 3.839 0.900 0.900 0.700 0.700 VeryRough
8 NONRES_ROOF 17 3 3 0.167 0.2284 0.750 0.900 0.450 0.700 Rough
9 NONRES_EXT_WALL_GRD 20 3 9 0.167 1.498 0.900 0.900 0.700 0.700 MediumRough
10 NONRES_EXT_WALL_MID 21 3 9 0.167 1.416 0.900 0.900 0.700 0.700 MediumRough
11 NONRES_EXT_WALL_TOP 22 3 9 0.167 1.867 0.900 0.900 0.700 0.700 MediumRough
12 BASEMENT_WALL_EAST_CFACTOR 39 2 7 0.167 0.9401 0.000 0.900 0.000 0.700 MediumRough
13 BASEMENT_WALL_SOUTH_CFACTOR 40 2 7 0.167 0.9401 0.000 0.900 0.000 0.700 MediumRough
14 BASEMENT_WALL_NORTH_CFACTOR 41 2 7 0.167 0.9401 0.000 0.900 0.000 0.700 MediumRough
15 DATACENTER_BASEMENT_ZN_6_WALL_NORTH_CFACTOR 42 2 7 0.167 0.9401 0.000 0.900 0.000 0.700 MediumRough
16 DATACENTER_BASEMENT_ZN_6_WALL_SOUTH_CFACTOR 43 2 7 0.167 0.9401 0.000 0.900 0.000 0.700 MediumRough
17 DATACENTER_BASEMENT_ZN_6_WALL_WEST_CFACTOR 44 2 7 0.167 0.9401 0.000 0.900 0.000 0.700 MediumRough


Material CTF Summary

Material Name Thickness {m} Conductivity {w/m-K} Density {kg/m3} Specific Heat {J/kg-K} ThermalResistance {m2-K/w}
1 OPAQUE DOOR PANEL_CON 0.0000 0.000 0.000 0.000 0.4760
2 STD WOOD 6INCH 0.1500 0.120 540.000 1210.000 1.250
3 AC02 ACOUSTIC CEILING 0.0127 0.057 288.000 1339.000 0.2228
4 G01 13MM GYPSUM BOARD 0.0127 0.160 800.000 1090.000 0.7937E-01
5 G01 13MM GYPSUM BOARD 0.0127 0.160 800.000 1090.000 0.7937E-01
6 200MM NORMALWEIGHT CONCRETE FLOOR 0.2032 2.310 2322.000 832.000 0.8797E-01
7 CP02 CARPET PAD 0.0000 0.000 0.000 0.000 0.2165
8 100MM NORMALWEIGHT CONCRETE FLOOR 0.1016 2.310 2322.000 832.000 0.4398E-01
9 CP02 CARPET PAD 0.0000 0.000 0.000 0.000 0.2165
10 CP02 CARPET PAD 0.0000 0.000 0.000 0.000 0.2165
11 100MM NORMALWEIGHT CONCRETE FLOOR 0.1016 2.310 2322.000 832.000 0.4398E-01
12 F13 BUILT-UP ROOFING 0.0095 0.160 1120.000 1460.000 0.5938E-01
13 NONRES_ROOF_INSULATION 0.0000 0.000 0.000 0.000 4.319
14 F08 METAL SURFACE 0.0008 45.280 7824.000 500.000 0.1767E-04
15 200MM NORMALWEIGHT CONCRETE WALL 0.2032 2.310 2322.000 832.000 0.8797E-01
16 NONRES_EXTERIOR_WALL_INSULATION_GRD 0.0000 0.000 0.000 0.000 0.5004
17 G01 13MM GYPSUM BOARD 0.0127 0.160 800.000 1090.000 0.7937E-01
18 200MM NORMALWEIGHT CONCRETE WALL 0.2032 2.310 2322.000 832.000 0.8797E-01
19 NONRES_EXTERIOR_WALL_INSULATION_MID 0.0000 0.000 0.000 0.000 0.5391
20 G01 13MM GYPSUM BOARD 0.0127 0.160 800.000 1090.000 0.7937E-01
21 200MM NORMALWEIGHT CONCRETE WALL 0.2032 2.310 2322.000 832.000 0.8797E-01
22 NONRES_EXTERIOR_WALL_INSULATION_TOP 0.0000 0.000 0.000 0.000 0.3683
23 G01 13MM GYPSUM BOARD 0.0127 0.160 800.000 1090.000 0.7937E-01
24 ~FC_Insulation_1 0.0000 0.000 0.000 0.000 0.9868
25 ~FC_Concrete 0.1500 1.950 2240.000 900.000 0.7692E-01
26 ~FC_Insulation_2 0.0000 0.000 0.000 0.000 0.9868
27 ~FC_Concrete 0.1500 1.950 2240.000 900.000 0.7692E-01
28 ~FC_Insulation_3 0.0000 0.000 0.000 0.000 0.9868
29 ~FC_Concrete 0.1500 1.950 2240.000 900.000 0.7692E-01
30 ~FC_Insulation_4 0.0000 0.000 0.000 0.000 0.9868
31 ~FC_Concrete 0.1500 1.950 2240.000 900.000 0.7692E-01
32 ~FC_Insulation_5 0.0000 0.000 0.000 0.000 0.9868
33 ~FC_Concrete 0.1500 1.950 2240.000 900.000 0.7692E-01
34 ~FC_Insulation_6 0.0000 0.000 0.000 0.000 0.9868
35 ~FC_Concrete 0.1500 1.950 2240.000 900.000 0.7692E-01


CTF

Time Outside Cross Inside Flux (except final one)
1 1 0.0000000 0.0000000 -0.0000000 -0.0000000
2 0 2.1009573 2.1009573 2.1009573  
3 9 -0.27580628E-02 0.97439125E-12 -0.27580628E-02 0.28516790E-03
4 8 0.73590997E-01 0.21837543E-08 0.73590997E-01 -0.77836043E-02
5 7 -0.82599318 0.23162835E-06 -0.82599318 0.89703933E-01
6 6 5.1113916 0.48671053E-05 5.1113916 -0.57224845
7 5 -19.214933 0.30163627E-04 -19.214933 2.2266322
8 4 45.557404 0.63181060E-04 45.557404 -5.4853312
9 3 -68.275533 0.44785456E-04 -68.275533 8.5710568
10 2 62.555368 0.93952058E-05 62.555368 -8.2111738
11 1 -31.904423 0.39200004E-06 -31.904423 4.3886678
12 0 6.9260389 0.77047546E-09 6.9260389  
13 3 -0.21589802E-09 0.15643069E-09 -0.21589802E-09 0.12999471E-21
14 2 0.50772448E-02 0.30006816E-02 0.50772448E-02 -0.13693132E-08
15 1 -2.5944910 1.4597758 -2.5944910 0.76344767E-02
16 0 7.0433378 2.9911476 7.0433378  
17 4 0.68458728E-09 0.26079551E-09 0.68458728E-09 -0.34507121E-18
18 3 -0.72180374E-03 0.24295686E-03 -0.72180374E-03 0.69691454E-09
19 2 0.83054762 0.27682775 0.83054762 -0.35168967E-03
20 1 -12.650482 3.3590720 -12.650482 0.19281313
21 0 16.907513 1.4507143 16.907513  
22 7 -0.18651654E-16 -0.16428647E-15 -0.26578847E-08 -0.25364002E-17
23 6 0.67402962E-01 0.99142722E-07 0.38101547E-02 -0.76639482E-03
24 5 -1.8580732 0.49502125E-04 -0.10651409 0.21891119E-01
25 4 18.220105 0.12801333E-02 1.0775450 -0.22586539
26 3 -79.928293 0.66708484E-02 -4.9803755 1.0625663
27 2 166.43177 0.75131194E-02 11.128837 -2.4125483
28 1 -159.97298 0.18548900E-02 -11.587784 2.5494418
29 0 57.057412 0.52755123E-04 4.4818272  
30 7 0.43260499E-16 0.34524919E-16 0.52793240E-17 0.0000000
31 6 0.69434179E-09 0.98085174E-11 0.18162501E-10 -0.40870994E-12
32 5 -0.12888762E-04 0.28373718E-06 -0.16918523E-06 0.92361873E-08
33 4 0.25174112E-01 0.33697681E-03 0.22646198E-03 -0.31467795E-04
34 3 -3.7600775 0.27170599E-01 -0.48495626E-01 0.94171705E-02
35 2 51.553741 0.22121684 1.2284947 -0.25833933
36 1 -128.86110 0.21944682 -5.1479470 1.1228340
37 0 81.526494 0.16043334E-01 4.4519351  
38 7 0.52793240E-17 0.34524919E-16 0.43260499E-16 0.0000000
39 6 0.18162501E-10 0.98085174E-11 0.69434179E-09 -0.40870994E-12
40 5 -0.16918523E-06 0.28373718E-06 -0.12888762E-04 0.92361873E-08
41 4 0.22646198E-03 0.33697681E-03 0.25174112E-01 -0.31467795E-04
42 3 -0.48495626E-01 0.27170599E-01 -3.7600775 0.94171705E-02
43 2 1.2284947 0.22121684 51.553741 -0.25833933
44 1 -5.1479470 0.21944682 -128.86110 1.1228340
45 0 4.4519351 0.16043334E-01 81.526494  
46 3 -0.62451068E-06 0.10350887E-08 -0.38276125E-05 0.11995084E-16
47 2 0.77976586 0.13989883E-02 1.0579789 -0.73382352E-06
48 1 -21.958702 0.93426804E-01 -6.3215779 0.20283230
49 0 21.361010 0.87247630E-01 5.4456762  
50 9 0.14091426E-14 0.48101397E-16 -0.12271849E-09 -0.49605034E-17
51 8 0.18065296E-07 0.19413100E-12 0.33649602E-03 -0.20540863E-09
52 7 -0.11004888E-01 0.10546945E-07 -0.21303752E-01 0.12512956E-03
53 6 0.37174157 0.37425545E-05 0.44335749 -0.43515980E-02
54 5 -4.8625044 0.14213861E-03 -4.2200868 0.59116134E-01
55 4 31.551289 0.11806248E-02 20.574731 -0.40285082
56 3 -108.13650 0.26081321E-02 -53.912227 1.4705586
57 2 194.06739 0.14847903E-02 76.306869 -2.8520668
58 1 -170.03224 0.16027253E-03 -54.802483 2.7257428
59 0 57.057407 0.92345258E-06 15.636386  
60 9 0.11726792E-14 0.46876770E-16 -0.12664795E-09 -0.40425794E-17
61 8 0.18621286E-07 0.18477046E-12 0.34269676E-03 -0.21173044E-09
62 7 -0.11191167E-01 0.99660246E-08 -0.21572393E-01 0.12724763E-03
63 6 0.37680492 0.35261678E-05 0.44770143 -0.44112820E-02
64 5 -4.9119389 0.13358806E-03 -4.2535898 0.59729078E-01
65 4 31.770087 0.11071467E-02 20.706000 -0.40575564
66 3 -108.60241 0.24410452E-02 -54.171883 1.4772891
67 2 194.52961 0.13872791E-02 76.544434 -2.8594062
68 1 -170.20315 0.14950961E-03 -54.870487 2.7287383
69 0 57.057407 0.85997654E-06 15.624277  
70 9 0.98458787E-15 0.55454857E-16 -0.10492535E-09 -0.15601002E-17
71 8 0.15540463E-07 0.23311053E-12 0.30746206E-03 -0.17670042E-09
72 7 -0.10129638E-01 0.13130386E-07 -0.20040359E-01 0.11517765E-03
73 6 0.34794661 0.47273228E-05 0.42286390 -0.40711180E-02
74 5 -4.6301347 0.18177508E-03 -4.0616887 0.56235001E-01
75 4 30.522476 0.15264987E-02 19.953355 -0.38919251
76 3 -105.94476 0.34047073E-02 -52.682811 1.4388992
77 2 191.89184 0.19546755E-02 75.183526 -2.8175246
78 1 -169.22736 0.21263380E-03 -54.483619 2.7116363
79 0 57.057407 0.12355163E-05 15.695393  
80 7 -0.41493644E-09 0.26375357E-16 0.26213203E-14 -0.63268016E-17
81 6 0.27465604E-04 0.18700671E-07 0.31288692E-02 -0.26247577E-04
82 5 -0.19935291E-02 0.11146933E-04 -0.22025565 0.19255324E-02
83 4 0.45890804E-01 0.50864553E-03 4.7717348 -0.44709298E-01
84 3 -0.40280019 0.40571884E-02 -37.694667 0.39504237
85 2 1.4296488 0.67623010E-02 115.84777 -1.4094303
86 1 -2.0629154 0.20697549E-02 -143.53273 2.0428830
87 0 1.0055995 0.48413807E-04 60.838472  
88 7 -0.41493644E-09 0.26375357E-16 0.26213203E-14 -0.63268016E-17
89 6 0.27465604E-04 0.18700671E-07 0.31288692E-02 -0.26247577E-04
90 5 -0.19935291E-02 0.11146933E-04 -0.22025565 0.19255324E-02
91 4 0.45890804E-01 0.50864553E-03 4.7717348 -0.44709298E-01
92 3 -0.40280019 0.40571884E-02 -37.694667 0.39504237
93 2 1.4296488 0.67623010E-02 115.84777 -1.4094303
94 1 -2.0629154 0.20697549E-02 -143.53273 2.0428830
95 0 1.0055995 0.48413807E-04 60.838472  
96 7 -0.41493644E-09 0.26375357E-16 0.26213203E-14 -0.63268016E-17
97 6 0.27465604E-04 0.18700671E-07 0.31288692E-02 -0.26247577E-04
98 5 -0.19935291E-02 0.11146933E-04 -0.22025565 0.19255324E-02
99 4 0.45890804E-01 0.50864553E-03 4.7717348 -0.44709298E-01
100 3 -0.40280019 0.40571884E-02 -37.694667 0.39504237
101 2 1.4296488 0.67623010E-02 115.84777 -1.4094303
102 1 -2.0629154 0.20697549E-02 -143.53273 2.0428830
103 0 1.0055995 0.48413807E-04 60.838472  
104 7 -0.41493644E-09 0.26375357E-16 0.26213203E-14 -0.63268016E-17
105 6 0.27465604E-04 0.18700671E-07 0.31288692E-02 -0.26247577E-04
106 5 -0.19935291E-02 0.11146933E-04 -0.22025565 0.19255324E-02
107 4 0.45890804E-01 0.50864553E-03 4.7717348 -0.44709298E-01
108 3 -0.40280019 0.40571884E-02 -37.694667 0.39504237
109 2 1.4296488 0.67623010E-02 115.84777 -1.4094303
110 1 -2.0629154 0.20697549E-02 -143.53273 2.0428830
111 0 1.0055995 0.48413807E-04 60.838472  
112 7 -0.41493644E-09 0.26375357E-16 0.26213203E-14 -0.63268016E-17
113 6 0.27465604E-04 0.18700671E-07 0.31288692E-02 -0.26247577E-04
114 5 -0.19935291E-02 0.11146933E-04 -0.22025565 0.19255324E-02
115 4 0.45890804E-01 0.50864553E-03 4.7717348 -0.44709298E-01
116 3 -0.40280019 0.40571884E-02 -37.694667 0.39504237
117 2 1.4296488 0.67623010E-02 115.84777 -1.4094303
118 1 -2.0629154 0.20697549E-02 -143.53273 2.0428830
119 0 1.0055995 0.48413807E-04 60.838472  
120 7 -0.41493644E-09 0.26375357E-16 0.26213203E-14 -0.63268016E-17
121 6 0.27465604E-04 0.18700671E-07 0.31288692E-02 -0.26247577E-04
122 5 -0.19935291E-02 0.11146933E-04 -0.22025565 0.19255324E-02
123 4 0.45890804E-01 0.50864553E-03 4.7717348 -0.44709298E-01
124 3 -0.40280019 0.40571884E-02 -37.694667 0.39504237
125 2 1.4296488 0.67623010E-02 115.84777 -1.4094303
126 1 -2.0629154 0.20697549E-02 -143.53273 2.0428830
127 0 1.0055995 0.48413807E-04 60.838472  


WindowConstruction

Construction Name Index #Layers Roughness Conductance {W/m2-K} Conductance (Before Adjusted) {W/m2-K} Convection Coefficient Adjustment Ratio SHGC Solar Transmittance at Normal Incidence Visible Transmittance at Normal Incidence
1 WINDOW_U_0.4237_SHGC_EAST_0.25 35 1 VerySmooth 2.408 2.408 1.000 0.251    
2 WINDOW_U_0.4237_SHGC_SOUTH_0.25 36 1 VerySmooth 2.408 2.408 1.000 0.251    
3 WINDOW_U_0.4237_SHGC_WEST_0.25 37 1 VerySmooth 2.408 2.408 1.000 0.251    
4 WINDOW_U_0.4237_SHGC_NORTH_0.25 38 1 VerySmooth 2.408 2.408 1.000 0.251    


WindowMaterial:Glazing

Material Name Optical Data Type Spectral Data Set Name Thickness {m} Solar Transmittance Front Solar Reflectance Back Solar Reflectance Visible Transmittance Front Visible Reflectance Back Visible Reflectance Infrared Transmittance Front Thermal Emissivity Back Thermal Emissivity Conductivity {W/m-K} Dirt Factor Solar Diffusing
1 GLAZING LAYER EAST SpectralAverage   2.98522E-002 0.16139 0.62038 0.62038 0.25000 0.16143 0.23877 0.00000 0.84000 0.84000 0.12245 1.00000 No
2 GLAZING LAYER SOUTH SpectralAverage   2.98522E-002 0.16139 0.62038 0.62038 0.25000 0.16143 0.23877 0.00000 0.84000 0.84000 0.12245 1.00000 No
3 GLAZING LAYER WEST SpectralAverage   2.98522E-002 0.16139 0.62038 0.62038 0.25000 0.16143 0.23877 0.00000 0.84000 0.84000 0.12245 1.00000 No
4 GLAZING LAYER NORTH SpectralAverage   2.98522E-002 0.16139 0.62038 0.62038 0.25000 0.16143 0.23877 0.00000 0.84000 0.84000 0.12245 1.00000 No


Shadowing/Sun Position Calculations Annual Simulations

Shading Calculation Method Shading Calculation Update Frequency Method Shading Calculation Update Frequency {days} Maximum Figures in Shadow Overlap Calculations {} Polygon Clipping Algorithm Pixel Counting Resolution Sky Diffuse Modeling Algorithm Output External Shading Calculation Results Disable Self-Shading Within Shading Zone Groups Disable Self-Shading From Shading Zone Groups to Other Zones
1 PolygonClipping Periodic 30 15000 SutherlandHodgman 512 SimpleSkyDiffuseModeling No No No


Enclosure/Window Adjacency Daylighting Counts

Enclosure Name Number of Exterior Windows Number of Exterior Windows in Adjacent Enclosures
1 PERIMETER_BOT_ZN_3 5 0
2 PERIMETER_BOT_ZN_2 3 0
3 PERIMETER_BOT_ZN_1 5 0
4 PERIMETER_BOT_ZN_4 3 0
5 PERIMETER_MID_ZN_3 1 0
6 PERIMETER_MID_ZN_2 1 0
7 PERIMETER_MID_ZN_1 1 0
8 PERIMETER_MID_ZN_4 1 0
9 PERIMETER_TOP_ZN_3 1 0
10 PERIMETER_TOP_ZN_2 1 0
11 PERIMETER_TOP_ZN_1 1 0
12 PERIMETER_TOP_ZN_4 1 0


Enclosure/Window Adjacency Daylighting Matrix

Enclosure Name Number of Adjacent Enclosures with Windows Adjacent Enclosure Names - 1st 100 (max)
1 PERIMETER_BOT_ZN_3 0  
2 PERIMETER_BOT_ZN_2 0  
3 PERIMETER_BOT_ZN_1 0  
4 PERIMETER_BOT_ZN_4 0  
5 PERIMETER_MID_ZN_3 0  
6 PERIMETER_MID_ZN_2 0  
7 PERIMETER_MID_ZN_1 0  
8 PERIMETER_MID_ZN_4 0  
9 PERIMETER_TOP_ZN_3 0  
10 PERIMETER_TOP_ZN_2 0  
11 PERIMETER_TOP_ZN_1 0  
12 PERIMETER_TOP_ZN_4 0  


Water Heater Information

Type Name Volume {m3} Maximum Capacity {W} Standard Rated Recovery Efficiency Standard Rated Energy Factor
1 WaterHeater:Mixed SWHSYS1 WATER HEATER 1.1356 87921.3 0.496 7.5104E-002


Surface Convection Parameters

Surface Name Outside Model Assignment Outside Area [m2] Outside Perimeter [m] Outside Height [m] Inside Model Assignment Inside Height [m] Inside Perimeter Envelope [m] Inside Hydraulic Diameter [m] Window Wall Ratio Window Location Near Radiant {Yes/No} Has Active HVAC {Yes/No}
1 BASEMENT_WALL_EAST 0 0.00 0.00 0.00 0 2.44 0.00 52.56 -999.00 0 No No
2 BASEMENT_WALL_SOUTH 0 0.00 0.00 0.00 0 2.44 0.00 52.56 -999.00 0 No No
3 BASEMENT_WALL_NORTH 0 0.00 0.00 0.00 0 2.44 0.00 52.56 -999.00 0 No No
4 BASEMENT_WALL_WEST 0 0.00 0.00 0.00 0 2.44 0.00 52.56 -999.00 0 No No
5 BASEMENT_FLOOR 0 0.00 0.00 0.00 0 2.44 0.00 52.56 -999.00 0 No No
6 PERIMETER_BOT_ZN_2_FLOOR-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.44 0.00 52.56 -999.00 0 No No
7 PERIMETER_BOT_ZN_1_FLOOR-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.44 0.00 52.56 -999.00 0 No No
8 CORE_BOT_ZN_5_FLOOR-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.44 0.00 52.56 -999.00 0 No No
9 PERIMETER_BOT_ZN_3_FLOOR-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.44 0.00 52.56 -999.00 0 No No
10 BASEMENT_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.44 0.00 52.56 -999.00 0 No No
11 CORE_BOT_ZN_5_WALL_SOUTH 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
12 CORE_BOT_ZN_5_WALL_WEST 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
13 CORE_BOT_ZN_5_WALL_NORTH 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
14 CORE_BOT_ZN_5_WALL_EAST 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
15 DATACENTER_BASEMENT_ZN_6_CEILING-CORE_BOT_ZN_5-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
16 CORE_BOT_ZN_5_FLOOR 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
17 CORE_BOT_ZN_5_CEILING 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
18 CORE_BOTTOM_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
19 CORE_MID_ZN_5_WALL_SOUTH 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
20 CORE_MID_ZN_5_WALL_WEST 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
21 CORE_MID_ZN_5_WALL_NORTH 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
22 CORE_MID_ZN_5_WALL_EAST 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
23 CORE_MID_ZN_5_FLOOR 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
24 CORE_MID_ZN_5_CEILING 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
25 CORE_MID_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
26 CORE_TOP_ZN_5_WALL_SOUTH 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
27 CORE_TOP_ZN_5_WALL_WEST 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
28 CORE_TOP_ZN_5_WALL_NORTH 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
29 CORE_TOP_ZN_5_WALL_EAST 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
30 CORE_TOP_ZN_5_FLOOR 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
31 CORE_TOP_ZN_5_CEILING 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
32 CORE_TOP_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.74 0.00 48.64 -999.00 0 No No
33 PERIMETER_BOT_ZN_3_WALL_NORTH 0 869.22 250.73 37.50 0 2.74 73.11 8.07 0.43 3 No No
34 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 0 869.22 250.73 37.50 0 2.74 73.11 8.07 0.43 2 No No
35 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 0 869.22 250.73 37.50 0 2.74 73.11 8.07 0.43 2 No No
36 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 0 869.22 250.73 37.50 0 2.74 73.11 8.07 0.43 2 No No
37 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 0 869.22 250.73 37.50 0 2.74 73.11 8.07 0.43 2 No No
38 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 0 869.22 250.73 37.50 0 2.74 73.11 8.07 0.43 2 No No
39 PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 0 869.22 250.73 37.50 0 2.74 73.11 8.07 0.43 0 No No
40 PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 0 869.22 250.73 37.50 0 2.74 73.11 8.07 0.43 0 No No
41 PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR3 0 869.22 250.73 37.50 0 2.74 73.11 8.07 0.43 0 No No
42 PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR4 0 869.22 250.73 37.50 0 2.74 73.11 8.07 0.43 0 No No
43 PERIMETER_BOT_ZN_3_WALL_WEST 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
44 CORE_BOT_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
45 PERIMETER_BOT_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
46 DATACENTER_BOT_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
47 PERIMETER_BOT_ZN_3_FLOOR 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
48 DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_3-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
49 PERIMETER_BOT_ZN_3_CEILING 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
50 PERIMETER_BOT_ZN_3_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
51 PERIMETER_BOT_ZN_2_WALL_EAST 0 579.48 250.73 37.50 0 2.74 48.74 7.58 0.43 3 No No
52 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 0 579.48 250.73 37.50 0 2.74 48.74 7.58 0.43 2 No No
53 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 0 579.48 250.73 37.50 0 2.74 48.74 7.58 0.43 2 No No
54 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 0 579.48 250.73 37.50 0 2.74 48.74 7.58 0.43 2 No No
55 PERIMETER_BOT_ZN_2_WALL_EAST_DOOR1 0 579.48 250.73 37.50 0 2.74 48.74 7.58 0.43 0 No No
56 PERIMETER_BOT_ZN_2_WALL_EAST_DOOR2 0 579.48 250.73 37.50 0 2.74 48.74 7.58 0.43 0 No No
57 PERIMETER_BOT_ZN_2_WALL_NORTH 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
58 CORE_BOT_ZN_5_WALL_EAST-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
59 PERIMETER_BOT_ZN_1_WALL_EAST-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
60 PERIMETER_BOT_ZN_2_FLOOR 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
61 PERIMETER_BOT_ZN_2_CEILING 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
62 PERIMETER_BOT_ZN_2_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
63 PERIMETER_BOT_ZN_1_WALL_SOUTH 0 869.22 221.21 37.50 0 2.74 73.11 8.07 0.43 3 No No
64 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 0 869.22 221.21 37.50 0 2.74 73.11 8.07 0.43 2 No No
65 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 0 869.22 221.21 37.50 0 2.74 73.11 8.07 0.43 2 No No
66 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 0 869.22 221.21 37.50 0 2.74 73.11 8.07 0.43 2 No No
67 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 0 869.22 221.21 37.50 0 2.74 73.11 8.07 0.43 2 No No
68 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 0 869.22 221.21 37.50 0 2.74 73.11 8.07 0.43 2 No No
69 PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 0 869.22 221.21 37.50 0 2.74 73.11 8.07 0.43 0 No No
70 PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 0 869.22 221.21 37.50 0 2.74 73.11 8.07 0.43 0 No No
71 PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR3 0 869.22 221.21 37.50 0 2.74 73.11 8.07 0.43 0 No No
72 PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR4 0 869.22 221.21 37.50 0 2.74 73.11 8.07 0.43 0 No No
73 PERIMETER_BOT_ZN_1_WALL_EAST 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
74 DATACENTER_BOT_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
75 PERIMETER_BOT_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
76 CORE_BOT_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
77 DATACENTER_BASEMENT_ZN_6-PERIMETER_BOT_ZN_1-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
78 PERIMETER_BOT_ZN_1_FLOOR 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
79 PERIMETER_BOT_ZN_1_CEILING 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
80 PERIMETER_BOT_ZN_1_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
81 PERIMETER_BOT_ZN_4_WALL_WEST 0 579.48 172.48 37.50 0 2.74 48.74 7.58 0.43 3 No No
82 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 0 579.48 172.48 37.50 0 2.74 48.74 7.58 0.43 2 No No
83 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 0 579.48 172.48 37.50 0 2.74 48.74 7.58 0.43 2 No No
84 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 0 579.48 172.48 37.50 0 2.74 48.74 7.58 0.43 2 No No
85 PERIMETER_BOT_ZN_4_WALL_WEST_DOOR1 0 579.48 172.48 37.50 0 2.74 48.74 7.58 0.43 0 No No
86 PERIMETER_BOT_ZN_4_WALL_WEST_DOOR2 0 579.48 172.48 37.50 0 2.74 48.74 7.58 0.43 0 No No
87 PERIMETER_BOT_ZN_4_WALL_SOUTH 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
88 DATACENTER_BOT_ZN_6_WALL_WEST-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
89 PERIMETER_BOT_ZN_3_WALL_WEST-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
90 PERIMETER_BOT_ZN_4_FLOOR 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
91 PERIMETER_BOT_ZN_4_CEILING 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
92 PERIMETER_BOT_ZN_4_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
93 PERIMETER_MID_ZN_3_WALL_NORTH 0 869.22 250.73 37.50 0 2.74 73.11 8.07 0.43 3 No No
94 PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW 0 869.22 250.73 37.50 0 2.74 73.11 8.07 0.43 2 No No
95 PERIMETER_MID_ZN_3_WALL_WEST 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
96 CORE_MID_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
97 PERIMETER_MID_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
98 DATACENTER_MID_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
99 PERIMETER_MID_ZN_3_FLOOR 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
100 PERIMETER_MID_ZN_3_CEILING 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
101 PERIMETER_MID_ZN_3_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
102 PERIMETER_MID_ZN_2_WALL_EAST 0 579.48 250.73 37.50 0 2.74 48.74 7.58 0.43 3 No No
103 PERIMETER_MID_ZN_2_WALL_EAST_WINDOW 0 579.48 250.73 37.50 0 2.74 48.74 7.58 0.43 2 No No
104 PERIMETER_MID_ZN_2_WALL_NORTH 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
105 CORE_MID_ZN_5_WALL_EAST-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
106 PERIMETER_MID_ZN_1_WALL_EAST-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
107 PERIMETER_MID_ZN_2_FLOOR 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
108 PERIMETER_MID_ZN_2_CEILING 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
109 PERIMETER_MID_ZN_2_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
110 PERIMETER_MID_ZN_1_WALL_EAST 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
111 PERIMETER_MID_ZN_1_WALL_SOUTH 0 869.22 221.21 37.50 0 2.74 73.11 8.07 0.43 3 No No
112 PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW 0 869.22 221.21 37.50 0 2.74 73.11 8.07 0.43 2 No No
113 DATACENTER_MID_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
114 PERIMETER_MID_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
115 CORE_MID_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
116 PERIMETER_MID_ZN_1_FLOOR 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
117 PERIMETER_MID_ZN_1_CEILING 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
118 PERIMETER_MID_ZN_1_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
119 PERIMETER_MID_ZN_4_WALL_WEST 0 579.48 172.48 37.50 0 2.74 48.74 7.58 0.43 3 No No
120 PERIMETER_MID_ZN_4_WALL_WEST_WINDOW 0 579.48 172.48 37.50 0 2.74 48.74 7.58 0.43 2 No No
121 PERIMETER_MID_ZN_4_WALL_SOUTH 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
122 DATACENTER_MID_ZN_6_WALL_WEST-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
123 PERIMETER_MID_ZN_3_WALL_WEST-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
124 PERIMETER_MID_ZN_4_FLOOR 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
125 PERIMETER_MID_ZN_4_CEILING 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
126 PERIMETER_MID_ZN_4_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
127 PERIMETER_TOP_ZN_3_WALL_NORTH 0 869.22 250.73 37.50 0 2.74 73.11 8.07 0.43 3 No No
128 PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW 0 869.22 250.73 37.50 0 2.74 73.11 8.07 0.43 2 No No
129 PERIMETER_TOP_ZN_3_WALL_WEST 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
130 CORE_TOP_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
131 PERIMETER_TOP_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
132 DATACENTER_TOP_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
133 PERIMETER_TOP_ZN_3_FLOOR 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
134 PERIMETER_TOP_ZN_3_CEILING 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
135 PERIMETER_TOP_ZN_3_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
136 PERIMETER_TOP_ZN_2_WALL_EAST 0 579.48 250.73 37.50 0 2.74 48.74 7.58 0.43 3 No No
137 PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW 0 579.48 250.73 37.50 0 2.74 48.74 7.58 0.43 2 No No
138 PERIMETER_TOP_ZN_2_WALL_NORTH 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
139 CORE_TOP_ZN_5_WALL_EAST-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
140 INT-PER3S-NE-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
141 PERIMETER_TOP_ZN_2_FLOOR 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
142 PERIMETER_TOP_ZN_2_CEILING 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
143 PERIMETER_TOP_ZN_2_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
144 PERIMETER_TOP_ZN_1_WALL_SOUTH 0 869.22 221.21 37.50 0 2.74 73.11 8.07 0.43 3 No No
145 PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW 0 869.22 221.21 37.50 0 2.74 73.11 8.07 0.43 2 No No
146 INT-PER3S-NE 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
147 DATACENTER_TOP_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
148 PERIMETER_TOP_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
149 CORE_TOP_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
150 PERIMETER_TOP_ZN_1_FLOOR 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
151 PERIMETER_TOP_ZN_1_CEILING 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
152 PERIMETER_TOP_ZN_1_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.74 73.11 8.07 0.43 0 No No
153 PERIMETER_TOP_ZN_4_WALL_WEST 0 579.48 172.48 37.50 0 2.74 48.74 7.58 0.43 3 No No
154 PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW 0 579.48 172.48 37.50 0 2.74 48.74 7.58 0.43 2 No No
155 PERIMETER_TOP_ZN_4_WALL_SOUTH 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
156 DATACENTER_TOP_ZN_6_WALL_WEST-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
157 PERIMETER_TOP_ZN_3_WALL_WEST-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
158 PERIMETER_TOP_ZN_4_FLOOR 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
159 PERIMETER_TOP_ZN_4_CEILING 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
160 PERIMETER_TOP_ZN_4_INTERNALMASS_1 0 0.00 0.00 0.00 0 2.74 48.74 7.58 0.43 0 No No
161 GROUNDFLOOR_PLENUM_WALL_NORTH 0 869.22 250.73 37.50 0 1.22 243.69 58.49 0.00 0 No No
162 GROUNDFLOOR_PLENUM_WEST 0 579.48 172.48 37.50 0 1.22 243.69 58.49 0.00 0 No No
163 GROUNDFLOOR_PLENUM_WALL_SOUTH 0 869.22 221.21 37.50 0 1.22 243.69 58.49 0.00 0 No No
164 GROUNDFLOOR_PLENUM_WALL_EAST 0 579.48 250.73 37.50 0 1.22 243.69 58.49 0.00 0 No No
165 iz-CORE_BOT_ZN_5_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
166 iz-PERIMETER_BOT_ZN_3_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
167 iz-PERIMETER_BOT_ZN_2_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
168 iz-PERIMETER_BOT_ZN_1_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
169 iz-PERIMETER_BOT_ZN_4_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
170 iz-DATACENTER_BOT_ZN_6_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
171 GROUNDFLOOR_PLENUM_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
172 MIDFLOOR_PLENUM_WALL_NORTH 0 869.22 250.73 37.50 0 1.22 243.69 58.49 0.00 0 No No
173 MIDFLOOR_PLENUM_WALL_WEST 0 579.48 172.48 37.50 0 1.22 243.69 58.49 0.00 0 No No
174 MIDFLOOR_PLENUM_WALL_SOUTH 0 869.22 221.21 37.50 0 1.22 243.69 58.49 0.00 0 No No
175 MIDFLOOR_PLENUM_WALL_EAST 0 579.48 250.73 37.50 0 1.22 243.69 58.49 0.00 0 No No
176 iz-CORE_MID_ZN_5_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
177 iz-PERIMETER_MID_ZN_3_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
178 iz-PERIMETER_MID_ZN_2_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
179 iz-PERIMETER_MID_ZN_1_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
180 iz-PERIMETER_MID_ZN_4_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
181 iz-DATACENTER_MID_ZN_6_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
182 MIDFLOOR_PLENUM_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
183 TOPFLOOR_PLENUM_WALL_NORTH 0 869.22 221.21 37.50 0 1.22 243.69 58.49 0.00 0 No No
184 TOPFLOOR_PLENUM_WALL_EAST 0 579.48 250.73 37.50 0 1.22 243.69 58.49 0.00 0 No No
185 TOPFLOOR_PLENUM_WALL_WEST 0 579.48 172.48 37.50 0 1.22 243.69 58.49 0.00 0 No No
186 TOPFLOOR_PLENUM_WALL_SOUTH 0 869.22 250.73 37.50 0 1.22 243.69 58.49 0.00 0 No No
187 iz-CORE_TOP_ZN_5_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
188 iz-PERIMETER_TOP_ZN_3_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
189 iz-PERIMETER_TOP_ZN_2_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
190 iz-PERIMETER_TOP_ZN_1_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
191 iz-PERIMETER_TOP_ZN_4_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
192 iz-DATACENTER_TOP_ZN_6_CEILING 0 0.00 0.00 0.00 0 1.22 243.69 58.49 0.00 0 No No
193 BUILDING_ROOF 0 3563.11 268.06 0.00 0 1.22 243.69 58.49 0.00 0 No No
194 DATACENTER_BOT_ZN_6_WALL_NORTH 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
195 DATACENTER_BOT_ZN_6_WALL_SOUTH 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
196 DATACENTER_BOT_ZN_6_WALL_EAST-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
197 DATACENTER_BOT_ZN_6_WALL_WEST 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
198 DATACENTER_BOT_ZN_6_FLOOR 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
199 DATACENTER_BOT_ZN_6_CEILING 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
200 DATACENTER_MID_ZN_6_WALL_WEST 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
201 DATACENTER_MID_ZN_6_WALL_SOUTH 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
202 DATACENTER_MID_ZN_6_WALL_EAST 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
203 DATACENTER_MID_ZN_6_WALL_NORTH 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
204 DATACENTER_MID_ZN_6_FLOOR 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
205 DATACENTER_MID_ZN_6_CEILING 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
206 DATACENTER_TOP_ZN_6_WALL_EAST 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
207 DATACENTER_TOP_ZN_6_WALL_WEST 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
208 DATACENTER_TOP_ZN_6_WALL_SOUTH 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
209 DATACENTER_TOP_ZN_6_WALL_NORTH 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
210 DATACENTER_TOP_ZN_6_FLOOR 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
211 DATACENTER_TOP_ZN_6_CEILING 0 0.00 0.00 0.00 0 2.74 0.00 1.79 -999.00 0 No No
212 DATACENTER_BASEMENT_ZN_6_WALL_NORTH 0 0.00 0.00 0.00 0 2.44 0.00 24.18 -999.00 0 No No
213 DATACENTER_BASEMENT_ZN_6_WALL_SOUTH 0 0.00 0.00 0.00 0 2.44 0.00 24.18 -999.00 0 No No
214 DATACENTER_BASEMENT_ZN_6_WALL_WEST 0 0.00 0.00 0.00 0 2.44 0.00 24.18 -999.00 0 No No
215 DATACENTER_BASEMENT_ZN_6_WALL_EAST 0 0.00 0.00 0.00 0 2.44 0.00 24.18 -999.00 0 No No
216 DATACENTER_BASEMENT_ZN_6_FLOOR 0 0.00 0.00 0.00 0 2.44 0.00 24.18 -999.00 0 No No
217 DATACENTER_BOT_ZN_6_FLOOR-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.44 0.00 24.18 -999.00 0 No No
218 DATACENTER_BASEMENT_ZN_6_CEILING-CORE_BOT_ZN_5 0 0.00 0.00 0.00 0 2.44 0.00 24.18 -999.00 0 No No
219 PERIMETER_BOT_ZN_4_FLOOR-PPAUTOCREATEOTHER 0 0.00 0.00 0.00 0 2.44 0.00 24.18 -999.00 0 No No
220 DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_1 0 0.00 0.00 0.00 0 2.44 0.00 24.18 -999.00 0 No No
221 DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_3 0 0.00 0.00 0.00 0 2.44 0.00 24.18 -999.00 0 No No


ZoneInfiltration Airflow Stats Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Design Volume Flow Rate {m3/s} Volume Flow Rate/Floor Area {m3/s-m2} Volume Flow Rate/Exterior Surface Area {m3/s-m2} ACH - Air Changes per Hour Equation A - Constant Term Coefficient {} Equation B - Temperature Term Coefficient {1/C} Equation C - Velocity Term Coefficient {s/m} Equation D - Velocity Squared Term Coefficient {s2/m2}
1 PERIMETER_BOT_ZN_3_INFILTRATION INFIL_SCH_PNNL PERIMETER_BOT_ZN_3 313.41 16.9 2.856E-002 9.114E-005 1.371E-004 0.120 0.000 0.000 0.224 0.000
2 PERIMETER_BOT_ZN_2_INFILTRATION INFIL_SCH_PNNL PERIMETER_BOT_ZN_2 201.98 10.9 1.904E-002 9.429E-005 1.384E-004 0.124 0.000 0.000 0.224 0.000
3 PERIMETER_BOT_ZN_1_INFILTRATION INFIL_SCH_PNNL PERIMETER_BOT_ZN_1 313.42 16.9 2.856E-002 9.114E-005 1.371E-004 0.120 0.000 0.000 0.224 0.000
4 PERIMETER_BOT_ZN_4_INFILTRATION INFIL_SCH_PNNL PERIMETER_BOT_ZN_4 201.98 10.9 1.904E-002 9.429E-005 1.384E-004 0.124 0.000 0.000 0.224 0.000
5 PERIMETER_MID_ZN_3_INFILTRATION INFIL_SCH_PNNL PERIMETER_MID_ZN_3 313.41 16.9 2.856E-002 9.114E-005 1.424E-004 0.120 0.000 0.000 0.224 0.000
6 PERIMETER_MID_ZN_2_INFILTRATION INFIL_SCH_PNNL PERIMETER_MID_ZN_2 201.98 10.9 1.904E-002 9.429E-005 1.424E-004 0.124 0.000 0.000 0.224 0.000
7 PERIMETER_MID_ZN_1_INFILTRATION INFIL_SCH_PNNL PERIMETER_MID_ZN_1 313.42 16.9 2.856E-002 9.114E-005 1.424E-004 0.120 0.000 0.000 0.224 0.000
8 PERIMETER_MID_ZN_4_INFILTRATION INFIL_SCH_PNNL PERIMETER_MID_ZN_4 201.98 10.9 1.904E-002 9.429E-005 1.424E-004 0.124 0.000 0.000 0.224 0.000
9 PERIMETER_TOP_ZN_3_INFILTRATION INFIL_SCH_PNNL PERIMETER_TOP_ZN_3 313.41 16.9 2.856E-002 9.114E-005 1.424E-004 0.120 0.000 0.000 0.224 0.000
10 PERIMETER_TOP_ZN_2_INFILTRATION INFIL_SCH_PNNL PERIMETER_TOP_ZN_2 201.98 10.9 1.904E-002 9.429E-005 1.424E-004 0.124 0.000 0.000 0.224 0.000
11 PERIMETER_TOP_ZN_1_INFILTRATION INFIL_SCH_PNNL PERIMETER_TOP_ZN_1 313.42 16.9 2.856E-002 9.114E-005 1.424E-004 0.120 0.000 0.000 0.224 0.000
12 PERIMETER_TOP_ZN_4_INFILTRATION INFIL_SCH_PNNL PERIMETER_TOP_ZN_4 201.98 10.9 1.904E-002 9.429E-005 1.424E-004 0.124 0.000 0.000 0.224 0.000
13 GROUNDFLOOR_PLENUM_INFILTRATION INFIL_SCH_PNNL GROUNDFLOOR_PLENUM 3563.11 0.0 4.231E-002 1.187E-005 1.424E-004 3.506E-002 0.000 0.000 0.224 0.000
14 MIDFLOOR_PLENUM_INFILTRATION INFIL_SCH_PNNL MIDFLOOR_PLENUM 3563.11 0.0 4.231E-002 1.187E-005 1.424E-004 3.506E-002 0.000 0.000 0.224 0.000
15 TOPFLOOR_PLENUM_INFILTRATION INFIL_SCH_PNNL TOPFLOOR_PLENUM 3563.11 0.0 4.231E-002 1.187E-005 1.096E-005 3.506E-002 0.000 0.000 0.224 0.000


AirFlow Model

Simple
1 Simple


RoomAir Model

Zone Name Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined
1 BASEMENT Mixing/Well-Stirred
2 CORE_BOTTOM Mixing/Well-Stirred
3 CORE_MID Mixing/Well-Stirred
4 CORE_TOP Mixing/Well-Stirred
5 PERIMETER_BOT_ZN_3 Mixing/Well-Stirred
6 PERIMETER_BOT_ZN_2 Mixing/Well-Stirred
7 PERIMETER_BOT_ZN_1 Mixing/Well-Stirred
8 PERIMETER_BOT_ZN_4 Mixing/Well-Stirred
9 PERIMETER_MID_ZN_3 Mixing/Well-Stirred
10 PERIMETER_MID_ZN_2 Mixing/Well-Stirred
11 PERIMETER_MID_ZN_1 Mixing/Well-Stirred
12 PERIMETER_MID_ZN_4 Mixing/Well-Stirred
13 PERIMETER_TOP_ZN_3 Mixing/Well-Stirred
14 PERIMETER_TOP_ZN_2 Mixing/Well-Stirred
15 PERIMETER_TOP_ZN_1 Mixing/Well-Stirred
16 PERIMETER_TOP_ZN_4 Mixing/Well-Stirred
17 GROUNDFLOOR_PLENUM Mixing/Well-Stirred
18 MIDFLOOR_PLENUM Mixing/Well-Stirred
19 TOPFLOOR_PLENUM Mixing/Well-Stirred
20 DATACENTER_BOT_ZN_6 Mixing/Well-Stirred
21 DATACENTER_MID_ZN_6 Mixing/Well-Stirred
22 DATACENTER_TOP_ZN_6 Mixing/Well-Stirred
23 DATACENTER_BASEMENT_ZN_6 Mixing/Well-Stirred


AirflowNetwork Model:Control

No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation
1 NoMultizoneOrDistribution


Zone Volume Capacitance Multiplier

Sensible Heat Capacity Multiplier Moisture Capacity Multiplier Carbon Dioxide Capacity Multiplier Generic Contaminant Capacity Multiplier
1 1.000 1.000 1.000 1.000


Load Timesteps in Zone Design Calculation Averaging Window

Value
1 6


Heating Sizing Factor Information

Sizing Factor ID Value
1 Global 1.0000


Cooling Sizing Factor Information

Sizing Factor ID Value
1 Global 1.0000


Sky Daylight Factors

Sky Type MonthAndDay Daylighting Control Name Enclosure Name Window Name Reference Point Daylight Factor
1 Clear Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 PERIMETER_BOT_ZN_1_DAYLREFPT1 2.8576E-003
2 Clear Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 PERIMETER_BOT_ZN_1_DAYLREFPT2 2.8588E-003
3 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 PERIMETER_BOT_ZN_1_DAYLREFPT1 3.0627E-003
4 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 PERIMETER_BOT_ZN_1_DAYLREFPT2 3.0636E-003
5 Intermediate Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 PERIMETER_BOT_ZN_1_DAYLREFPT1 2.1965E-003
6 Intermediate Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 PERIMETER_BOT_ZN_1_DAYLREFPT2 2.1972E-003
7 Overcast Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 PERIMETER_BOT_ZN_1_DAYLREFPT1 1.2447E-003
8 Overcast Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 PERIMETER_BOT_ZN_1_DAYLREFPT2 1.2452E-003
9 Clear Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 PERIMETER_BOT_ZN_1_DAYLREFPT1 2.8841E-003
10 Clear Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 PERIMETER_BOT_ZN_1_DAYLREFPT2 2.9574E-003
11 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 PERIMETER_BOT_ZN_1_DAYLREFPT1 3.0842E-003
12 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 PERIMETER_BOT_ZN_1_DAYLREFPT2 3.1455E-003
13 Intermediate Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 PERIMETER_BOT_ZN_1_DAYLREFPT1 2.2138E-003
14 Intermediate Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 PERIMETER_BOT_ZN_1_DAYLREFPT2 2.2647E-003
15 Overcast Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 PERIMETER_BOT_ZN_1_DAYLREFPT1 1.2574E-003
16 Overcast Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 PERIMETER_BOT_ZN_1_DAYLREFPT2 1.2891E-003
17 Clear Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 PERIMETER_BOT_ZN_1_DAYLREFPT1 7.9514E-002
18 Clear Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 PERIMETER_BOT_ZN_1_DAYLREFPT2 3.5821E-002
19 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 PERIMETER_BOT_ZN_1_DAYLREFPT1 8.9420E-002
20 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 PERIMETER_BOT_ZN_1_DAYLREFPT2 3.9097E-002
21 Intermediate Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 PERIMETER_BOT_ZN_1_DAYLREFPT1 6.1838E-002
22 Intermediate Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 PERIMETER_BOT_ZN_1_DAYLREFPT2 2.3924E-002
23 Overcast Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 PERIMETER_BOT_ZN_1_DAYLREFPT1 2.6042E-002
24 Overcast Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 PERIMETER_BOT_ZN_1_DAYLREFPT2 9.1095E-003
25 Clear Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 PERIMETER_BOT_ZN_1_DAYLREFPT1 2.8923E-003
26 Clear Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 PERIMETER_BOT_ZN_1_DAYLREFPT2 2.9988E-003
27 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 PERIMETER_BOT_ZN_1_DAYLREFPT1 3.0932E-003
28 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 PERIMETER_BOT_ZN_1_DAYLREFPT2 3.1909E-003
29 Intermediate Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 PERIMETER_BOT_ZN_1_DAYLREFPT1 2.2216E-003
30 Intermediate Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 PERIMETER_BOT_ZN_1_DAYLREFPT2 2.2944E-003
31 Overcast Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 PERIMETER_BOT_ZN_1_DAYLREFPT1 1.2577E-003
32 Overcast Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 PERIMETER_BOT_ZN_1_DAYLREFPT2 1.2900E-003
33 Clear Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 PERIMETER_BOT_ZN_1_DAYLREFPT1 2.8576E-003
34 Clear Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 PERIMETER_BOT_ZN_1_DAYLREFPT2 2.8591E-003
35 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 PERIMETER_BOT_ZN_1_DAYLREFPT1 3.0626E-003
36 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 PERIMETER_BOT_ZN_1_DAYLREFPT2 3.0639E-003
37 Intermediate Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 PERIMETER_BOT_ZN_1_DAYLREFPT1 2.1965E-003
38 Intermediate Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 PERIMETER_BOT_ZN_1_DAYLREFPT2 2.1974E-003
39 Overcast Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 PERIMETER_BOT_ZN_1_DAYLREFPT1 1.2447E-003
40 Overcast Sky 01/21 PERIMETER_BOT_ZN_1_DAYLCTRL PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 PERIMETER_BOT_ZN_1_DAYLREFPT2 1.2451E-003
41 Clear Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 PERIMETER_BOT_ZN_2_DAYLREFPT1 2.9893E-003
42 Clear Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 PERIMETER_BOT_ZN_2_DAYLREFPT2 3.1535E-003
43 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 PERIMETER_BOT_ZN_2_DAYLREFPT1 2.9090E-003
44 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 PERIMETER_BOT_ZN_2_DAYLREFPT2 3.0865E-003
45 Intermediate Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 PERIMETER_BOT_ZN_2_DAYLREFPT1 2.6660E-003
46 Intermediate Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 PERIMETER_BOT_ZN_2_DAYLREFPT2 2.7416E-003
47 Overcast Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 PERIMETER_BOT_ZN_2_DAYLREFPT1 2.1302E-003
48 Overcast Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 PERIMETER_BOT_ZN_2_DAYLREFPT2 2.1521E-003
49 Clear Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 PERIMETER_BOT_ZN_2_DAYLREFPT1 3.6649E-002
50 Clear Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 PERIMETER_BOT_ZN_2_DAYLREFPT2 1.7784E-002
51 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 PERIMETER_BOT_ZN_2_DAYLREFPT1 3.5899E-002
52 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 PERIMETER_BOT_ZN_2_DAYLREFPT2 1.6705E-002
53 Intermediate Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 PERIMETER_BOT_ZN_2_DAYLREFPT1 3.6669E-002
54 Intermediate Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 PERIMETER_BOT_ZN_2_DAYLREFPT2 1.5111E-002
55 Overcast Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 PERIMETER_BOT_ZN_2_DAYLREFPT1 2.6787E-002
56 Overcast Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 PERIMETER_BOT_ZN_2_DAYLREFPT2 9.9865E-003
57 Clear Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 PERIMETER_BOT_ZN_2_DAYLREFPT1 2.9489E-003
58 Clear Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 PERIMETER_BOT_ZN_2_DAYLREFPT2 3.0027E-003
59 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 PERIMETER_BOT_ZN_2_DAYLREFPT1 2.8579E-003
60 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 PERIMETER_BOT_ZN_2_DAYLREFPT2 2.8975E-003
61 Intermediate Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 PERIMETER_BOT_ZN_2_DAYLREFPT1 2.6437E-003
62 Intermediate Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 PERIMETER_BOT_ZN_2_DAYLREFPT2 2.6612E-003
63 Overcast Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 PERIMETER_BOT_ZN_2_DAYLREFPT1 2.1303E-003
64 Overcast Sky 01/21 PERIMETER_BOT_ZN_2_DAYLCTRL PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 PERIMETER_BOT_ZN_2_DAYLREFPT2 2.1525E-003
65 Clear Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 PERIMETER_BOT_ZN_3_DAYLREFPT1 1.2519E-003
66 Clear Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 PERIMETER_BOT_ZN_3_DAYLREFPT2 1.2531E-003
67 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 PERIMETER_BOT_ZN_3_DAYLREFPT1 1.0708E-003
68 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 PERIMETER_BOT_ZN_3_DAYLREFPT2 1.0718E-003
69 Intermediate Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 PERIMETER_BOT_ZN_3_DAYLREFPT1 9.5534E-004
70 Intermediate Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 PERIMETER_BOT_ZN_3_DAYLREFPT2 9.5613E-004
71 Overcast Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 PERIMETER_BOT_ZN_3_DAYLREFPT1 1.2447E-003
72 Overcast Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 PERIMETER_BOT_ZN_3_DAYLREFPT2 1.2452E-003
73 Clear Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 PERIMETER_BOT_ZN_3_DAYLREFPT1 1.2802E-003
74 Clear Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 PERIMETER_BOT_ZN_3_DAYLREFPT2 1.3489E-003
75 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 PERIMETER_BOT_ZN_3_DAYLREFPT1 1.0943E-003
76 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 PERIMETER_BOT_ZN_3_DAYLREFPT2 1.1498E-003
77 Intermediate Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 PERIMETER_BOT_ZN_3_DAYLREFPT1 9.7508E-004
78 Intermediate Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 PERIMETER_BOT_ZN_3_DAYLREFPT2 1.0180E-003
79 Overcast Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 PERIMETER_BOT_ZN_3_DAYLREFPT1 1.2577E-003
80 Overcast Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 PERIMETER_BOT_ZN_3_DAYLREFPT2 1.2900E-003
81 Clear Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 PERIMETER_BOT_ZN_3_DAYLREFPT1 1.9763E-002
82 Clear Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 PERIMETER_BOT_ZN_3_DAYLREFPT2 1.1285E-002
83 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 PERIMETER_BOT_ZN_3_DAYLREFPT1 1.5382E-002
84 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 PERIMETER_BOT_ZN_3_DAYLREFPT2 8.6054E-003
85 Intermediate Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 PERIMETER_BOT_ZN_3_DAYLREFPT1 1.5549E-002
86 Intermediate Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 PERIMETER_BOT_ZN_3_DAYLREFPT2 6.1673E-003
87 Overcast Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 PERIMETER_BOT_ZN_3_DAYLREFPT1 2.6042E-002
88 Overcast Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 PERIMETER_BOT_ZN_3_DAYLREFPT2 9.1067E-003
89 Clear Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 PERIMETER_BOT_ZN_3_DAYLREFPT1 1.2777E-003
90 Clear Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 PERIMETER_BOT_ZN_3_DAYLREFPT2 1.3470E-003
91 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 PERIMETER_BOT_ZN_3_DAYLREFPT1 1.0909E-003
92 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 PERIMETER_BOT_ZN_3_DAYLREFPT2 1.1437E-003
93 Intermediate Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 PERIMETER_BOT_ZN_3_DAYLREFPT1 9.6906E-004
94 Intermediate Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 PERIMETER_BOT_ZN_3_DAYLREFPT2 9.9954E-004
95 Overcast Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 PERIMETER_BOT_ZN_3_DAYLREFPT1 1.2574E-003
96 Overcast Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 PERIMETER_BOT_ZN_3_DAYLREFPT2 1.2891E-003
97 Clear Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 PERIMETER_BOT_ZN_3_DAYLREFPT1 1.2518E-003
98 Clear Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 PERIMETER_BOT_ZN_3_DAYLREFPT2 1.2530E-003
99 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 PERIMETER_BOT_ZN_3_DAYLREFPT1 1.0707E-003
100 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 PERIMETER_BOT_ZN_3_DAYLREFPT2 1.0716E-003
101 Intermediate Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 PERIMETER_BOT_ZN_3_DAYLREFPT1 9.5522E-004
102 Intermediate Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 PERIMETER_BOT_ZN_3_DAYLREFPT2 9.5579E-004
103 Overcast Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 PERIMETER_BOT_ZN_3_DAYLREFPT1 1.2447E-003
104 Overcast Sky 01/21 PERIMETER_BOT_ZN_3_DAYLCTRL PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 PERIMETER_BOT_ZN_3_DAYLREFPT2 1.2451E-003
105 Clear Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 PERIMETER_BOT_ZN_4_DAYLREFPT1 2.3645E-003
106 Clear Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 PERIMETER_BOT_ZN_4_DAYLREFPT2 2.4222E-003
107 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 PERIMETER_BOT_ZN_4_DAYLREFPT1 2.1390E-003
108 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 PERIMETER_BOT_ZN_4_DAYLREFPT2 2.1805E-003
109 Intermediate Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 PERIMETER_BOT_ZN_4_DAYLREFPT1 2.1397E-003
110 Intermediate Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 PERIMETER_BOT_ZN_4_DAYLREFPT2 2.1547E-003
111 Overcast Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 PERIMETER_BOT_ZN_4_DAYLREFPT1 2.1303E-003
112 Overcast Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 PERIMETER_BOT_ZN_4_DAYLREFPT2 2.1525E-003
113 Clear Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 PERIMETER_BOT_ZN_4_DAYLREFPT1 2.5180E-002
114 Clear Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 PERIMETER_BOT_ZN_4_DAYLREFPT2 1.3326E-002
115 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 PERIMETER_BOT_ZN_4_DAYLREFPT1 2.1920E-002
116 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 PERIMETER_BOT_ZN_4_DAYLREFPT2 1.1281E-002
117 Intermediate Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 PERIMETER_BOT_ZN_4_DAYLREFPT1 2.6222E-002
118 Intermediate Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 PERIMETER_BOT_ZN_4_DAYLREFPT2 1.1005E-002
119 Overcast Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 PERIMETER_BOT_ZN_4_DAYLREFPT1 2.6787E-002
120 Overcast Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 PERIMETER_BOT_ZN_4_DAYLREFPT2 9.9865E-003
121 Clear Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 PERIMETER_BOT_ZN_4_DAYLREFPT1 2.3925E-003
122 Clear Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 PERIMETER_BOT_ZN_4_DAYLREFPT2 2.4998E-003
123 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 PERIMETER_BOT_ZN_4_DAYLREFPT1 2.1750E-003
124 Clear Turbid Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 PERIMETER_BOT_ZN_4_DAYLREFPT2 2.2820E-003
125 Intermediate Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 PERIMETER_BOT_ZN_4_DAYLREFPT1 2.1598E-003
126 Intermediate Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 PERIMETER_BOT_ZN_4_DAYLREFPT2 2.2218E-003
127 Overcast Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 PERIMETER_BOT_ZN_4_DAYLREFPT1 2.1302E-003
128 Overcast Sky 01/21 PERIMETER_BOT_ZN_4_DAYLCTRL PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 PERIMETER_BOT_ZN_4_DAYLREFPT2 2.1521E-003
129 Clear Sky 01/21 PERIMETER_MID_ZN_1_DAYLCTRL PERIMETER_MID_ZN_1 PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW PERIMETER_MID_ZN_1_DAYLREFPT1 8.0715E-002
130 Clear Sky 01/21 PERIMETER_MID_ZN_1_DAYLCTRL PERIMETER_MID_ZN_1 PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW PERIMETER_MID_ZN_1_DAYLREFPT2 4.7955E-002
131 Clear Turbid Sky 01/21 PERIMETER_MID_ZN_1_DAYLCTRL PERIMETER_MID_ZN_1 PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW PERIMETER_MID_ZN_1_DAYLREFPT1 8.9227E-002
132 Clear Turbid Sky 01/21 PERIMETER_MID_ZN_1_DAYLCTRL PERIMETER_MID_ZN_1 PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW PERIMETER_MID_ZN_1_DAYLREFPT2 5.2135E-002
133 Intermediate Sky 01/21 PERIMETER_MID_ZN_1_DAYLCTRL PERIMETER_MID_ZN_1 PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW PERIMETER_MID_ZN_1_DAYLREFPT1 6.5812E-002
134 Intermediate Sky 01/21 PERIMETER_MID_ZN_1_DAYLCTRL PERIMETER_MID_ZN_1 PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW PERIMETER_MID_ZN_1_DAYLREFPT2 3.3388E-002
135 Overcast Sky 01/21 PERIMETER_MID_ZN_1_DAYLCTRL PERIMETER_MID_ZN_1 PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW PERIMETER_MID_ZN_1_DAYLREFPT1 3.0133E-002
136 Overcast Sky 01/21 PERIMETER_MID_ZN_1_DAYLCTRL PERIMETER_MID_ZN_1 PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW PERIMETER_MID_ZN_1_DAYLREFPT2 1.4574E-002
137 Clear Sky 01/21 PERIMETER_MID_ZN_2_DAYLCTRL PERIMETER_MID_ZN_2 PERIMETER_MID_ZN_2_WALL_EAST_WINDOW PERIMETER_MID_ZN_2_DAYLREFPT1 4.1810E-002
138 Clear Sky 01/21 PERIMETER_MID_ZN_2_DAYLCTRL PERIMETER_MID_ZN_2 PERIMETER_MID_ZN_2_WALL_EAST_WINDOW PERIMETER_MID_ZN_2_DAYLREFPT2 2.4404E-002
139 Clear Turbid Sky 01/21 PERIMETER_MID_ZN_2_DAYLCTRL PERIMETER_MID_ZN_2 PERIMETER_MID_ZN_2_WALL_EAST_WINDOW PERIMETER_MID_ZN_2_DAYLREFPT1 4.0992E-002
140 Clear Turbid Sky 01/21 PERIMETER_MID_ZN_2_DAYLCTRL PERIMETER_MID_ZN_2 PERIMETER_MID_ZN_2_WALL_EAST_WINDOW PERIMETER_MID_ZN_2_DAYLREFPT2 2.3184E-002
141 Intermediate Sky 01/21 PERIMETER_MID_ZN_2_DAYLCTRL PERIMETER_MID_ZN_2 PERIMETER_MID_ZN_2_WALL_EAST_WINDOW PERIMETER_MID_ZN_2_DAYLREFPT1 4.1418E-002
142 Intermediate Sky 01/21 PERIMETER_MID_ZN_2_DAYLCTRL PERIMETER_MID_ZN_2 PERIMETER_MID_ZN_2_WALL_EAST_WINDOW PERIMETER_MID_ZN_2_DAYLREFPT2 2.1001E-002
143 Overcast Sky 01/21 PERIMETER_MID_ZN_2_DAYLCTRL PERIMETER_MID_ZN_2 PERIMETER_MID_ZN_2_WALL_EAST_WINDOW PERIMETER_MID_ZN_2_DAYLREFPT1 3.0820E-002
144 Overcast Sky 01/21 PERIMETER_MID_ZN_2_DAYLCTRL PERIMETER_MID_ZN_2 PERIMETER_MID_ZN_2_WALL_EAST_WINDOW PERIMETER_MID_ZN_2_DAYLREFPT2 1.4729E-002
145 Clear Sky 01/21 PERIMETER_MID_ZN_3_DAYLCTRL PERIMETER_MID_ZN_3 PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW PERIMETER_MID_ZN_3_DAYLREFPT1 2.3737E-002
146 Clear Sky 01/21 PERIMETER_MID_ZN_3_DAYLCTRL PERIMETER_MID_ZN_3 PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW PERIMETER_MID_ZN_3_DAYLREFPT2 1.6608E-002
147 Clear Turbid Sky 01/21 PERIMETER_MID_ZN_3_DAYLCTRL PERIMETER_MID_ZN_3 PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW PERIMETER_MID_ZN_3_DAYLREFPT1 1.8955E-002
148 Clear Turbid Sky 01/21 PERIMETER_MID_ZN_3_DAYLCTRL PERIMETER_MID_ZN_3 PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW PERIMETER_MID_ZN_3_DAYLREFPT2 1.3196E-002
149 Intermediate Sky 01/21 PERIMETER_MID_ZN_3_DAYLCTRL PERIMETER_MID_ZN_3 PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW PERIMETER_MID_ZN_3_DAYLREFPT1 1.9079E-002
150 Intermediate Sky 01/21 PERIMETER_MID_ZN_3_DAYLCTRL PERIMETER_MID_ZN_3 PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW PERIMETER_MID_ZN_3_DAYLREFPT2 1.0403E-002
151 Overcast Sky 01/21 PERIMETER_MID_ZN_3_DAYLCTRL PERIMETER_MID_ZN_3 PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW PERIMETER_MID_ZN_3_DAYLREFPT1 3.0133E-002
152 Overcast Sky 01/21 PERIMETER_MID_ZN_3_DAYLCTRL PERIMETER_MID_ZN_3 PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW PERIMETER_MID_ZN_3_DAYLREFPT2 1.4571E-002
153 Clear Sky 01/21 PERIMETER_MID_ZN_4_DAYLCTRL PERIMETER_MID_ZN_4 PERIMETER_MID_ZN_4_WALL_WEST_WINDOW PERIMETER_MID_ZN_4_DAYLREFPT1 2.9382E-002
154 Clear Sky 01/21 PERIMETER_MID_ZN_4_DAYLCTRL PERIMETER_MID_ZN_4 PERIMETER_MID_ZN_4_WALL_WEST_WINDOW PERIMETER_MID_ZN_4_DAYLREFPT2 1.8591E-002
155 Clear Turbid Sky 01/21 PERIMETER_MID_ZN_4_DAYLCTRL PERIMETER_MID_ZN_4 PERIMETER_MID_ZN_4_WALL_WEST_WINDOW PERIMETER_MID_ZN_4_DAYLREFPT1 2.5823E-002
156 Clear Turbid Sky 01/21 PERIMETER_MID_ZN_4_DAYLCTRL PERIMETER_MID_ZN_4 PERIMETER_MID_ZN_4_WALL_WEST_WINDOW PERIMETER_MID_ZN_4_DAYLREFPT2 1.6090E-002
157 Intermediate Sky 01/21 PERIMETER_MID_ZN_4_DAYLCTRL PERIMETER_MID_ZN_4 PERIMETER_MID_ZN_4_WALL_WEST_WINDOW PERIMETER_MID_ZN_4_DAYLREFPT1 3.0182E-002
158 Intermediate Sky 01/21 PERIMETER_MID_ZN_4_DAYLCTRL PERIMETER_MID_ZN_4 PERIMETER_MID_ZN_4_WALL_WEST_WINDOW PERIMETER_MID_ZN_4_DAYLREFPT2 1.5792E-002
159 Overcast Sky 01/21 PERIMETER_MID_ZN_4_DAYLCTRL PERIMETER_MID_ZN_4 PERIMETER_MID_ZN_4_WALL_WEST_WINDOW PERIMETER_MID_ZN_4_DAYLREFPT1 3.0820E-002
160 Overcast Sky 01/21 PERIMETER_MID_ZN_4_DAYLCTRL PERIMETER_MID_ZN_4 PERIMETER_MID_ZN_4_WALL_WEST_WINDOW PERIMETER_MID_ZN_4_DAYLREFPT2 1.4729E-002
161 Clear Sky 01/21 PERIMETER_TOP_ZN_1_DAYLCTRL PERIMETER_TOP_ZN_1 PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW PERIMETER_TOP_ZN_1_DAYLREFPT1 8.0678E-002
162 Clear Sky 01/21 PERIMETER_TOP_ZN_1_DAYLCTRL PERIMETER_TOP_ZN_1 PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW PERIMETER_TOP_ZN_1_DAYLREFPT2 4.8033E-002
163 Clear Turbid Sky 01/21 PERIMETER_TOP_ZN_1_DAYLCTRL PERIMETER_TOP_ZN_1 PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW PERIMETER_TOP_ZN_1_DAYLREFPT1 8.9195E-002
164 Clear Turbid Sky 01/21 PERIMETER_TOP_ZN_1_DAYLCTRL PERIMETER_TOP_ZN_1 PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW PERIMETER_TOP_ZN_1_DAYLREFPT2 5.2230E-002
165 Intermediate Sky 01/21 PERIMETER_TOP_ZN_1_DAYLCTRL PERIMETER_TOP_ZN_1 PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW PERIMETER_TOP_ZN_1_DAYLREFPT1 6.5838E-002
166 Intermediate Sky 01/21 PERIMETER_TOP_ZN_1_DAYLCTRL PERIMETER_TOP_ZN_1 PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW PERIMETER_TOP_ZN_1_DAYLREFPT2 3.3458E-002
167 Overcast Sky 01/21 PERIMETER_TOP_ZN_1_DAYLCTRL PERIMETER_TOP_ZN_1 PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW PERIMETER_TOP_ZN_1_DAYLREFPT1 3.0168E-002
168 Overcast Sky 01/21 PERIMETER_TOP_ZN_1_DAYLCTRL PERIMETER_TOP_ZN_1 PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW PERIMETER_TOP_ZN_1_DAYLREFPT2 1.4602E-002
169 Clear Sky 01/21 PERIMETER_TOP_ZN_2_DAYLCTRL PERIMETER_TOP_ZN_2 PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW PERIMETER_TOP_ZN_2_DAYLREFPT1 4.1798E-002
170 Clear Sky 01/21 PERIMETER_TOP_ZN_2_DAYLCTRL PERIMETER_TOP_ZN_2 PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW PERIMETER_TOP_ZN_2_DAYLREFPT2 2.4428E-002
171 Clear Turbid Sky 01/21 PERIMETER_TOP_ZN_2_DAYLCTRL PERIMETER_TOP_ZN_2 PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW PERIMETER_TOP_ZN_2_DAYLREFPT1 4.0990E-002
172 Clear Turbid Sky 01/21 PERIMETER_TOP_ZN_2_DAYLCTRL PERIMETER_TOP_ZN_2 PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW PERIMETER_TOP_ZN_2_DAYLREFPT2 2.3211E-002
173 Intermediate Sky 01/21 PERIMETER_TOP_ZN_2_DAYLCTRL PERIMETER_TOP_ZN_2 PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW PERIMETER_TOP_ZN_2_DAYLREFPT1 4.1435E-002
174 Intermediate Sky 01/21 PERIMETER_TOP_ZN_2_DAYLCTRL PERIMETER_TOP_ZN_2 PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW PERIMETER_TOP_ZN_2_DAYLREFPT2 2.1038E-002
175 Overcast Sky 01/21 PERIMETER_TOP_ZN_2_DAYLCTRL PERIMETER_TOP_ZN_2 PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW PERIMETER_TOP_ZN_2_DAYLREFPT1 3.0854E-002
176 Overcast Sky 01/21 PERIMETER_TOP_ZN_2_DAYLCTRL PERIMETER_TOP_ZN_2 PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW PERIMETER_TOP_ZN_2_DAYLREFPT2 1.4757E-002
177 Clear Sky 01/21 PERIMETER_TOP_ZN_3_DAYLCTRL PERIMETER_TOP_ZN_3 PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW PERIMETER_TOP_ZN_3_DAYLREFPT1 2.3708E-002
178 Clear Sky 01/21 PERIMETER_TOP_ZN_3_DAYLCTRL PERIMETER_TOP_ZN_3 PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW PERIMETER_TOP_ZN_3_DAYLREFPT2 1.6614E-002
179 Clear Turbid Sky 01/21 PERIMETER_TOP_ZN_3_DAYLCTRL PERIMETER_TOP_ZN_3 PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW PERIMETER_TOP_ZN_3_DAYLREFPT1 1.8936E-002
180 Clear Turbid Sky 01/21 PERIMETER_TOP_ZN_3_DAYLCTRL PERIMETER_TOP_ZN_3 PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW PERIMETER_TOP_ZN_3_DAYLREFPT2 1.3202E-002
181 Intermediate Sky 01/21 PERIMETER_TOP_ZN_3_DAYLCTRL PERIMETER_TOP_ZN_3 PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW PERIMETER_TOP_ZN_3_DAYLREFPT1 1.9089E-002
182 Intermediate Sky 01/21 PERIMETER_TOP_ZN_3_DAYLCTRL PERIMETER_TOP_ZN_3 PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW PERIMETER_TOP_ZN_3_DAYLREFPT2 1.0418E-002
183 Overcast Sky 01/21 PERIMETER_TOP_ZN_3_DAYLCTRL PERIMETER_TOP_ZN_3 PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW PERIMETER_TOP_ZN_3_DAYLREFPT1 3.0168E-002
184 Overcast Sky 01/21 PERIMETER_TOP_ZN_3_DAYLCTRL PERIMETER_TOP_ZN_3 PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW PERIMETER_TOP_ZN_3_DAYLREFPT2 1.4599E-002
185 Clear Sky 01/21 PERIMETER_TOP_ZN_4_DAYLCTRL PERIMETER_TOP_ZN_4 PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW PERIMETER_TOP_ZN_4_DAYLREFPT1 2.9362E-002
186 Clear Sky 01/21 PERIMETER_TOP_ZN_4_DAYLCTRL PERIMETER_TOP_ZN_4 PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW PERIMETER_TOP_ZN_4_DAYLREFPT2 1.8605E-002
187 Clear Turbid Sky 01/21 PERIMETER_TOP_ZN_4_DAYLCTRL PERIMETER_TOP_ZN_4 PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW PERIMETER_TOP_ZN_4_DAYLREFPT1 2.5810E-002
188 Clear Turbid Sky 01/21 PERIMETER_TOP_ZN_4_DAYLCTRL PERIMETER_TOP_ZN_4 PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW PERIMETER_TOP_ZN_4_DAYLREFPT2 1.6103E-002
189 Intermediate Sky 01/21 PERIMETER_TOP_ZN_4_DAYLCTRL PERIMETER_TOP_ZN_4 PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW PERIMETER_TOP_ZN_4_DAYLREFPT1 3.0194E-002
190 Intermediate Sky 01/21 PERIMETER_TOP_ZN_4_DAYLCTRL PERIMETER_TOP_ZN_4 PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW PERIMETER_TOP_ZN_4_DAYLREFPT2 1.5817E-002
191 Overcast Sky 01/21 PERIMETER_TOP_ZN_4_DAYLCTRL PERIMETER_TOP_ZN_4 PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW PERIMETER_TOP_ZN_4_DAYLREFPT1 3.0854E-002
192 Overcast Sky 01/21 PERIMETER_TOP_ZN_4_DAYLCTRL PERIMETER_TOP_ZN_4 PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW PERIMETER_TOP_ZN_4_DAYLREFPT2 1.4757E-002


Zone Sizing Information

Zone Name Load Type Calc Des Load {W} User Des Load {W} Calc Des Air Flow Rate {m3/s} User Des Air Flow Rate {m3/s} Design Day Name Date/Time of Peak Temperature at Peak {C} Humidity Ratio at Peak {kgWater/kgDryAir} Floor Area {m2} # Occupants Calc Outdoor Air Flow Rate {m3/s} Calc DOAS Heat Addition Rate {W}
1 BASEMENT Cooling 66277.48296 66277.48296 4.94705 4.94705 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 27.37000 1.44605E-002 2779.42662 149.60210 1.20019 0.00000
2 BASEMENT Heating 0.00000 0.00000 0.00000 1.20019 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:30:00 -6.30000 2.29779E-003 2779.42662 149.60210 1.20019 0.00000
3 CORE_BOTTOM Cooling 72448.23817 72448.23817 5.40819 5.40819 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 27.37000 1.44605E-002 2496.12046 134.35320 1.07782 0.00000
4 CORE_BOTTOM Heating 0.00000 0.00000 0.00000 1.07782 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 06:20:00 -6.30000 2.29779E-003 2496.12046 134.35320 1.07782 0.00000
5 CORE_MID Cooling 680540.15617 680540.15617 50.78684 50.78684 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 27.37000 1.44605E-002 2496.12046 134.35320 10.77825 0.00000
6 CORE_MID Heating 241022.24925 241022.24925 10.53194 10.77825 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 -6.30000 2.29779E-003 2496.12046 134.35320 10.77825 0.00000
7 CORE_TOP Cooling 67530.42472 67530.42472 5.03951 5.03951 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 27.37000 1.44605E-002 2496.12046 134.35320 1.07782 0.00000
8 CORE_TOP Heating 58466.64340 58466.64340 2.57635 2.57635 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 -6.30000 2.29779E-003 2496.12046 134.35320 1.07782 0.00000
9 PERIMETER_BOT_ZN_3 Cooling 11685.62599 11685.62599 0.87314 0.87314 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 27.37000 1.44605E-002 313.41284 16.86939 0.13533 0.00000
10 PERIMETER_BOT_ZN_3 Heating 7750.79874 7750.79874 0.34167 0.34167 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 -6.30000 2.29779E-003 313.41284 16.86939 0.13533 0.00000
11 PERIMETER_BOT_ZN_2 Cooling 11657.88190 11657.88190 0.87852 0.87852 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 09:50:00 30.52083 1.44662E-002 201.97515 10.87127 8.72129E-002 0.00000
12 PERIMETER_BOT_ZN_2 Heating 5396.63744 5396.63744 0.23801 0.23801 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 -6.30000 2.29779E-003 201.97515 10.87127 8.72129E-002 0.00000
13 PERIMETER_BOT_ZN_1 Cooling 13517.11727 13517.11727 1.01864 1.01864 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:50:00 34.32083 1.44731E-002 313.41969 16.86975 0.13533 0.00000
14 PERIMETER_BOT_ZN_1 Heating 9115.86371 9115.86371 0.40220 0.40220 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 -6.30000 2.29779E-003 313.41969 16.86975 0.13533 0.00000
15 PERIMETER_BOT_ZN_4 Cooling 15230.41218 15230.41218 1.14774 1.14774 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:10:00 32.91167 1.44705E-002 201.97515 10.87127 8.72129E-002 0.00000
16 PERIMETER_BOT_ZN_4 Heating 3804.06644 3804.06644 0.16733 0.16733 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 -6.30000 2.29779E-003 201.97515 10.87127 8.72129E-002 0.00000
17 PERIMETER_MID_ZN_3 Cooling 109114.89872 109114.89872 8.15131 8.15131 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 27.37000 1.44605E-002 313.41284 16.86939 1.35332 0.00000
18 PERIMETER_MID_ZN_3 Heating 137469.39816 137469.39816 6.07457 6.07457 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 -6.30000 2.29779E-003 313.41284 16.86939 1.35332 0.00000
19 PERIMETER_MID_ZN_2 Cooling 119922.26272 119922.26272 9.03731 9.03731 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:00:00 30.79000 1.44667E-002 201.97515 10.87127 0.87213 0.00000
20 PERIMETER_MID_ZN_2 Heating 90158.89053 90158.89053 3.98421 3.98421 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 -6.30000 2.29779E-003 201.97515 10.87127 0.87213 0.00000
21 PERIMETER_MID_ZN_1 Cooling 125553.29731 125553.29731 9.46171 9.46171 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 34.40000 1.44733E-002 313.41969 16.86975 1.35335 0.00000
22 PERIMETER_MID_ZN_1 Heating 135827.78976 135827.78976 6.00178 6.00178 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 -6.30000 2.29779E-003 313.41969 16.86975 1.35335 0.00000
23 PERIMETER_MID_ZN_4 Cooling 126285.02039 126285.02039 9.51680 9.51680 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:20:00 32.75333 1.44703E-002 201.97515 10.87127 0.87213 0.00000
24 PERIMETER_MID_ZN_4 Heating 85962.67608 85962.67608 3.79819 3.79819 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 -6.30000 2.29779E-003 201.97515 10.87127 0.87213 0.00000
25 PERIMETER_TOP_ZN_3 Cooling 12383.29773 12383.29773 0.93321 0.93321 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:30:00 34.11500 1.44727E-002 313.41284 16.86939 0.13533 0.00000
26 PERIMETER_TOP_ZN_3 Heating 18165.57428 18165.57428 0.80334 0.80334 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 -6.30000 2.29779E-003 313.41284 16.86939 0.13533 0.00000
27 PERIMETER_TOP_ZN_2 Cooling 12299.71558 12299.71558 0.92691 0.92691 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:20:00 31.26500 1.44675E-002 201.97515 10.87127 8.72129E-002 0.00000
28 PERIMETER_TOP_ZN_2 Heating 11850.93567 11850.93567 0.52410 0.52410 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 -6.30000 2.29779E-003 201.97515 10.87127 8.72129E-002 0.00000
29 PERIMETER_TOP_ZN_1 Cooling 14147.26960 14147.26960 1.06614 1.06614 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:20:00 34.40000 1.44733E-002 313.41969 16.86975 0.13533 0.00000
30 PERIMETER_TOP_ZN_1 Heating 17970.66285 17970.66285 0.79470 0.79470 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 -6.30000 2.29779E-003 313.41969 16.86975 0.13533 0.00000
31 PERIMETER_TOP_ZN_4 Cooling 13790.78937 13790.78937 1.03927 1.03927 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:20:00 32.75333 1.44703E-002 201.97515 10.87127 8.72129E-002 0.00000
32 PERIMETER_TOP_ZN_4 Heating 11580.08615 11580.08615 0.51210 0.51210 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 -6.30000 2.29779E-003 201.97515 10.87127 8.72129E-002 0.00000
33 DATACENTER_BOT_ZN_6 Cooling 7971.90558 7971.90558 0.47378 0.47378 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:20:00 24.96333 1.44561E-002 36.20274 1.94861 1.56328E-002 0.00000
34 DATACENTER_BOT_ZN_6 Heating 0.00000 0.00000 0.00000 1.56328E-002 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 06:20:00 -6.30000 2.29779E-003 36.20274 1.94861 1.56328E-002 0.00000
35 DATACENTER_MID_ZN_6 Cooling 75795.72127 75795.72127 4.50464 4.50464 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:20:00 24.96333 1.44561E-002 36.20274 1.94861 0.15633 0.00000
36 DATACENTER_MID_ZN_6 Heating 0.00000 0.00000 0.00000 0.15633 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 05:40:00 -6.30000 2.29779E-003 36.20274 1.94861 0.15633 0.00000
37 DATACENTER_TOP_ZN_6 Cooling 7693.75701 7693.75701 0.45731 0.45731 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.69500 1.44665E-002 36.20274 1.94861 1.56328E-002 0.00000
38 DATACENTER_TOP_ZN_6 Heating 0.00000 0.00000 0.00000 1.56328E-002 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 05:40:00 -6.30000 2.29779E-003 36.20274 1.94861 1.56328E-002 0.00000
39 DATACENTER_BASEMENT_ZN_6 Cooling 369399.38099 369399.38099 21.95600 21.95600 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 07:00:00 25.75500 1.44575E-002 783.67941 42.18139 0.33840 0.00000
40 DATACENTER_BASEMENT_ZN_6 Heating 0.00000 0.00000 0.00000 0.33840 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 03:40:00 -6.30000 2.29779E-003 783.67941 42.18139 0.33840 0.00000


System Sizing Information

System Name Load Type Peak Load Kind User Design Capacity Calc Des Air Flow Rate [m3/s] User Des Air Flow Rate [m3/s] Design Day Name Date/Time of Peak
1 VAV_BOT WITH REHEAT Cooling Sensible 137238.19 8.63114 8.63114 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 00:00:00
2 VAV_BOT WITH REHEAT Heating Sensible 49623.59 2.22703 2.22703 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00
3 VAV_MID WITH REHEAT Cooling Sensible 1249632.13 79.89447 79.89447 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 00:00:00
4 VAV_MID WITH REHEAT Heating Sensible 565526.55 30.63700 30.63700 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 14:40:00
5 VAV_TOP WITH REHEAT Cooling Sensible 141990.81 8.57101 8.57101 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 00:00:00
6 VAV_TOP WITH REHEAT Heating Sensible 56447.33 5.21061 5.21061 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 22:10:00
7 CAV_BAS Cooling Sensible 70882.29 4.94705 4.94705 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
8 CAV_BAS Heating Sensible 64827.56 1.20019 1.20019 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00
9 AIRLOOP DATACENTER BOT Cooling Sensible 7860.67 0.47378 0.47378 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
10 AIRLOOP DATACENTER BOT Heating Sensible 844.40 1.56328E-002 1.56328E-002 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00
11 AIRLOOP DATACENTER MID Cooling Sensible 74906.34 4.50464 4.50464 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
12 AIRLOOP DATACENTER MID Heating Sensible 8443.96 0.15633 0.15633 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00
13 AIRLOOP DATACENTER TOP Cooling Sensible 7642.21 0.45731 0.45731 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
14 AIRLOOP DATACENTER TOP Heating Sensible 844.40 1.56328E-002 1.56328E-002 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00


Component Sizing Information

Component Type Component Name Input Field Description Value
1 AirTerminal:SingleDuct:ConstantVolume:NoReheat BASEMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 4.94705
2 AirTerminal:SingleDuct:VAV:Reheat CORE_BOTTOM VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 5.40819
3 AirTerminal:SingleDuct:VAV:Reheat CORE_BOTTOM VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.35170
4 AirTerminal:SingleDuct:VAV:Reheat CORE_BOTTOM VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.34600
5 AirTerminal:SingleDuct:VAV:Reheat CORE_BOTTOM VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 1.87123
6 AirTerminal:SingleDuct:VAV:Reheat CORE_BOTTOM VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.93786
7 AirTerminal:SingleDuct:VAV:Reheat CORE_BOTTOM VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
8 AirTerminal:SingleDuct:VAV:Reheat CORE_BOTTOM VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 1.08332E-003
9 AirTerminal:SingleDuct:VAV:Reheat CORE_BOTTOM VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 1.58918E-004
10 AirTerminal:SingleDuct:VAV:Reheat CORE_BOTTOM VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 1.87123
11 AirTerminal:SingleDuct:VAV:Reheat CORE_BOTTOM VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 12.80000
12 AirTerminal:SingleDuct:VAV:Reheat CORE_BOTTOM VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
13 Coil:Heating:Water CORE_BOTTOM VAV BOX REHEAT COIL Design Size Rated Capacity [W] 18165.29953
14 Coil:Heating:Water CORE_BOTTOM VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 1.58918E-004
15 Coil:Heating:Water CORE_BOTTOM VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 366.19818
16 AirTerminal:SingleDuct:VAV:Reheat CORE_MID VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 50.78684
17 AirTerminal:SingleDuct:VAV:Reheat CORE_MID VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.37452
18 AirTerminal:SingleDuct:VAV:Reheat CORE_MID VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.35900
19 AirTerminal:SingleDuct:VAV:Reheat CORE_MID VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 18.23248
20 AirTerminal:SingleDuct:VAV:Reheat CORE_MID VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.99871
21 AirTerminal:SingleDuct:VAV:Reheat CORE_MID VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
22 AirTerminal:SingleDuct:VAV:Reheat CORE_MID VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 1.01732E-003
23 AirTerminal:SingleDuct:VAV:Reheat CORE_MID VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 3.65700E-003
24 AirTerminal:SingleDuct:VAV:Reheat CORE_MID VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 18.23248
25 AirTerminal:SingleDuct:VAV:Reheat CORE_MID VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 12.80000
26 AirTerminal:SingleDuct:VAV:Reheat CORE_MID VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
27 Coil:Heating:Water CORE_MID VAV BOX REHEAT COIL Design Size Rated Capacity [W] 418017.03534
28 Coil:Heating:Water CORE_MID VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 3.65700E-003
29 Coil:Heating:Water CORE_MID VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 9750.66957
30 AirTerminal:SingleDuct:VAV:Reheat CORE_TOP VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 5.03951
31 AirTerminal:SingleDuct:VAV:Reheat CORE_TOP VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.37743
32 AirTerminal:SingleDuct:VAV:Reheat CORE_TOP VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.37000
33 AirTerminal:SingleDuct:VAV:Reheat CORE_TOP VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 1.86462
34 AirTerminal:SingleDuct:VAV:Reheat CORE_TOP VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 1.00000
35 AirTerminal:SingleDuct:VAV:Reheat CORE_TOP VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
36 AirTerminal:SingleDuct:VAV:Reheat CORE_TOP VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 1.00947E-003
37 AirTerminal:SingleDuct:VAV:Reheat CORE_TOP VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 7.30293E-004
38 AirTerminal:SingleDuct:VAV:Reheat CORE_TOP VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 2.57635
39 AirTerminal:SingleDuct:VAV:Reheat CORE_TOP VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 12.80000
40 AirTerminal:SingleDuct:VAV:Reheat CORE_TOP VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
41 Coil:Heating:Water CORE_TOP VAV BOX REHEAT COIL Design Size Rated Capacity [W] 83477.02417
42 Coil:Heating:Water CORE_TOP VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 7.30293E-004
43 Coil:Heating:Water CORE_TOP VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 2203.93056
44 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_3 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 0.87314
45 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_3 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.27352
46 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_3 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.26900
47 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_3 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 0.23487
48 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_3 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.72939
49 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_3 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
50 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_3 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 1.39295E-003
51 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_3 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 9.68032E-005
52 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_3 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 0.34167
53 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_3 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 12.80000
54 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_3 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
55 Coil:Heating:Water PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 11065.20485
56 Coil:Heating:Water PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 9.68032E-005
57 Coil:Heating:Water PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 292.07438
58 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_2 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 0.87852
59 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_2 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.17519
60 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_2 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.20000
61 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_2 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 0.17570
62 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_2 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.46716
63 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_2 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
64 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_2 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 2.17483E-003
65 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_2 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 6.74123E-005
66 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_2 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 0.23801
67 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_2 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 12.80000
68 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_2 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
69 Coil:Heating:Water PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 7705.64208
70 Coil:Heating:Water PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 6.74123E-005
71 Coil:Heating:Water PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 203.36815
72 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_1 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 1.01864
73 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_1 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.23446
74 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_1 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.23000
75 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_1 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 0.23429
76 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_1 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.62522
77 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_1 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
78 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_1 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 1.62503E-003
79 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_1 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 1.13889E-004
80 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 0.40220
81 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 12.80000
82 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
83 Coil:Heating:Water PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 13018.23060
84 Coil:Heating:Water PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 1.13889E-004
85 Coil:Heating:Water PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 343.54040
86 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_4 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 1.14774
87 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_4 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.13409
88 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_4 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.20000
89 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_4 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 0.22955
90 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_4 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.35758
91 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_4 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
92 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_4 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 2.84128E-003
93 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_4 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 5.27509E-005
94 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_4 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 0.22955
95 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_4 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 12.80000
96 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_BOT_ZN_4 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
97 Coil:Heating:Water PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 6029.75767
98 Coil:Heating:Water PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 5.27509E-005
99 Coil:Heating:Water PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 146.62155
100 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_3 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 8.15131
101 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_3 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.29298
102 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_3 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.28100
103 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_3 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 2.29052
104 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_3 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.78129
105 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_3 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
106 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_3 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 1.30041E-003
107 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_3 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 1.71829E-003
108 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_3 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 6.07457
109 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_3 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 12.80000
110 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_3 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
111 Coil:Heating:Water PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 196410.77443
112 Coil:Heating:Water PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 1.71829E-003
113 Coil:Heating:Water PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 5180.58096
114 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_2 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 9.03731
115 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_2 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.17030
116 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_2 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.20000
117 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_2 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 1.80746
118 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_2 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.45413
119 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_2 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
120 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_2 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 2.23723E-003
121 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_2 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 1.12695E-003
122 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_2 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 3.98421
123 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_2 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 12.80000
124 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_2 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
125 Coil:Heating:Water PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 128817.44996
126 Coil:Heating:Water PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 1.12695E-003
127 Coil:Heating:Water PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 3397.65985
128 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_1 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 9.46171
129 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_1 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.25241
130 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_1 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.24200
131 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_1 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 2.28973
132 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_1 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.67310
133 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_1 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
134 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_1 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 1.50943E-003
135 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_1 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 1.69774E-003
136 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 6.00178
137 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 12.80000
138 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
139 Coil:Heating:Water PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 194062.31937
140 Coil:Heating:Water PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 1.69774E-003
141 Coil:Heating:Water PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 5118.70058
142 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_4 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 9.51680
143 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_4 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.16172
144 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_4 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.20000
145 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_4 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 1.90336
146 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_4 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.43125
147 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_4 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
148 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_4 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 2.35593E-003
149 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_4 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 1.07444E-003
150 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_4 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 3.79819
151 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_4 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 12.80000
152 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_MID_ZN_4 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
153 Coil:Heating:Water PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 122814.76572
154 Coil:Heating:Water PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 1.07444E-003
155 Coil:Heating:Water PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 3239.47637
156 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_3 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 0.93321
157 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_3 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.25591
158 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_3 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.25100
159 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_3 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 0.23424
160 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_3 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.68243
161 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_3 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
162 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_3 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 1.48879E-003
163 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_3 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 2.27117E-004
164 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_3 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 0.80334
165 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_3 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 12.80000
166 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_3 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
167 Coil:Heating:Water PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 25960.81687
168 Coil:Heating:Water PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 2.27117E-004
169 Coil:Heating:Water PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 684.58139
170 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_2 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 0.92691
171 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_2 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.16604
172 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_2 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.20000
173 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_2 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 0.18538
174 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_2 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.44278
175 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_2 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
176 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_2 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 2.29461E-003
177 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_2 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 1.48168E-004
178 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_2 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 0.52410
179 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_2 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 12.80000
180 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_2 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
181 Coil:Heating:Water PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 16936.52801
182 Coil:Heating:Water PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 1.48168E-004
183 Coil:Heating:Water PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 446.60816
184 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_1 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 1.06614
185 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_1 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.22401
186 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_1 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.22000
187 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_1 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 0.23455
188 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_1 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.59736
189 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_1 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
190 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_1 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 1.70082E-003
191 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_1 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 2.24677E-004
192 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 0.79470
193 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 12.80000
194 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_1 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
195 Coil:Heating:Water PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 25682.01350
196 Coil:Heating:Water PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 2.24677E-004
197 Coil:Heating:Water PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 677.23519
198 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_4 VAV BOX COMPONENT Design Size Maximum Air Flow Rate [m3/s] 1.03927
199 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_4 VAV BOX COMPONENT Design Size Constant Minimum Air Flow Fraction 0.14809
200 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_4 VAV BOX COMPONENT User-Specified Constant Minimum Air Flow Fraction 0.20000
201 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_4 VAV BOX COMPONENT Design Size Minimum Air Flow Rate [m3/s] 0.20785
202 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_4 VAV BOX COMPONENT Design Size Maximum Flow Fraction during Reheat [] 0.39490
203 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_4 VAV BOX COMPONENT User-Specified Maximum Flow Fraction during Reheat [] 0.50000
204 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_4 VAV BOX COMPONENT Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] 2.57278E-003
205 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_4 VAV BOX COMPONENT Design Size Maximum Reheat Water Flow Rate [m3/s] 1.44779E-004
206 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_4 VAV BOX COMPONENT Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] 0.51210
207 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_4 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Temperature [C] 12.80000
208 AirTerminal:SingleDuct:VAV:Reheat PERIMETER_TOP_ZN_4 VAV BOX COMPONENT Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] 8.00000E-003
209 Coil:Heating:Water PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL Design Size Rated Capacity [W] 16549.15744
210 Coil:Heating:Water PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL Design Size Maximum Water Flow Rate [m3/s] 1.44779E-004
211 Coil:Heating:Water PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL Design Size U-Factor Times Area Value [W/K] 436.39945
212 AirTerminal:SingleDuct:ConstantVolume:NoReheat DATACENTER_BOT_ZN_6 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.47378
213 AirTerminal:SingleDuct:ConstantVolume:NoReheat DATACENTER_MID_ZN_6 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 4.50464
214 AirTerminal:SingleDuct:ConstantVolume:NoReheat DATACENTER_TOP_ZN_6 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.45731
215 ZoneHVAC:IdealLoadsAirSystem AIRLOOP DATACENTER BASEMENT Design Size Maximum Heating Air Flow Rate [m3/s] 0.33840
216 ZoneHVAC:IdealLoadsAirSystem AIRLOOP DATACENTER BASEMENT Design Size Maximum Cooling Air Flow Rate [m3/s] 21.95600
217 AirLoopHVAC VAV_BOT WITH REHEAT Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 4.66311
218 AirLoopHVAC VAV_BOT WITH REHEAT Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 2.74565
219 AirLoopHVAC VAV_BOT WITH REHEAT Sum of Air Terminal Maximum Flow Rates [m3/s] 9.32622
220 AirLoopHVAC VAV_BOT WITH REHEAT Adjusted Heating Design Air Flow Rate [m3/s] 2.74565
221 AirLoopHVAC VAV_BOT WITH REHEAT Adjusted Cooling Design Air Flow Rate [m3/s] 8.63114
222 AirLoopHVAC VAV_BOT WITH REHEAT Adjusted Main Design Air Flow Rate [m3/s] 8.63114
223 AirLoopHVAC VAV_BOT WITH REHEAT User Heating Air Flow Ratio [] 0.30000
224 AirLoopHVAC VAV_BOT WITH REHEAT Calculated Heating Air Flow Ratio [] 0.31811
225 AirLoopHVAC VAV_MID WITH REHEAT Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 43.47698
226 AirLoopHVAC VAV_MID WITH REHEAT Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 26.52355
227 AirLoopHVAC VAV_MID WITH REHEAT Sum of Air Terminal Maximum Flow Rates [m3/s] 86.95397
228 AirLoopHVAC VAV_MID WITH REHEAT Adjusted Heating Design Air Flow Rate [m3/s] 30.63700
229 AirLoopHVAC VAV_MID WITH REHEAT Adjusted Cooling Design Air Flow Rate [m3/s] 79.89447
230 AirLoopHVAC VAV_MID WITH REHEAT Adjusted Main Design Air Flow Rate [m3/s] 79.89447
231 AirLoopHVAC VAV_MID WITH REHEAT User Heating Air Flow Ratio [] 0.30000
232 AirLoopHVAC VAV_MID WITH REHEAT Calculated Heating Air Flow Ratio [] 0.38347
233 AirLoopHVAC VAV_TOP WITH REHEAT Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 4.50252
234 AirLoopHVAC VAV_TOP WITH REHEAT Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 2.72664
235 AirLoopHVAC VAV_TOP WITH REHEAT Sum of Air Terminal Maximum Flow Rates [m3/s] 9.00505
236 AirLoopHVAC VAV_TOP WITH REHEAT Adjusted Heating Design Air Flow Rate [m3/s] 5.21061
237 AirLoopHVAC VAV_TOP WITH REHEAT Adjusted Cooling Design Air Flow Rate [m3/s] 8.57101
238 AirLoopHVAC VAV_TOP WITH REHEAT Adjusted Main Design Air Flow Rate [m3/s] 8.57101
239 AirLoopHVAC VAV_TOP WITH REHEAT User Heating Air Flow Ratio [] 0.30000
240 AirLoopHVAC VAV_TOP WITH REHEAT Calculated Heating Air Flow Ratio [] 0.60793
241 AirLoopHVAC CAV_BAS Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 4.94705
242 AirLoopHVAC CAV_BAS Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 4.94705
243 AirLoopHVAC CAV_BAS Sum of Air Terminal Maximum Flow Rates [m3/s] 4.94705
244 AirLoopHVAC CAV_BAS Adjusted Heating Design Air Flow Rate [m3/s] 4.94705
245 AirLoopHVAC CAV_BAS Adjusted Cooling Design Air Flow Rate [m3/s] 4.94705
246 AirLoopHVAC CAV_BAS Adjusted Main Design Air Flow Rate [m3/s] 4.94705
247 AirLoopHVAC CAV_BAS User Heating Air Flow Ratio [] 1.00000
248 AirLoopHVAC CAV_BAS Calculated Heating Air Flow Ratio [] 1.00000
249 AirLoopHVAC AIRLOOP DATACENTER BOT Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.47378
250 AirLoopHVAC AIRLOOP DATACENTER BOT Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.47378
251 AirLoopHVAC AIRLOOP DATACENTER BOT Sum of Air Terminal Maximum Flow Rates [m3/s] 0.47378
252 AirLoopHVAC AIRLOOP DATACENTER BOT Adjusted Heating Design Air Flow Rate [m3/s] 0.47378
253 AirLoopHVAC AIRLOOP DATACENTER BOT Adjusted Cooling Design Air Flow Rate [m3/s] 0.47378
254 AirLoopHVAC AIRLOOP DATACENTER BOT Adjusted Main Design Air Flow Rate [m3/s] 0.47378
255 AirLoopHVAC AIRLOOP DATACENTER BOT User Heating Air Flow Ratio [] 1.00000
256 AirLoopHVAC AIRLOOP DATACENTER BOT Calculated Heating Air Flow Ratio [] 1.00000
257 AirLoopHVAC AIRLOOP DATACENTER MID Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 4.50464
258 AirLoopHVAC AIRLOOP DATACENTER MID Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 4.50464
259 AirLoopHVAC AIRLOOP DATACENTER MID Sum of Air Terminal Maximum Flow Rates [m3/s] 4.50464
260 AirLoopHVAC AIRLOOP DATACENTER MID Adjusted Heating Design Air Flow Rate [m3/s] 4.50464
261 AirLoopHVAC AIRLOOP DATACENTER MID Adjusted Cooling Design Air Flow Rate [m3/s] 4.50464
262 AirLoopHVAC AIRLOOP DATACENTER MID Adjusted Main Design Air Flow Rate [m3/s] 4.50464
263 AirLoopHVAC AIRLOOP DATACENTER MID User Heating Air Flow Ratio [] 1.00000
264 AirLoopHVAC AIRLOOP DATACENTER MID Calculated Heating Air Flow Ratio [] 1.00000
265 AirLoopHVAC AIRLOOP DATACENTER TOP Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.45731
266 AirLoopHVAC AIRLOOP DATACENTER TOP Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.45731
267 AirLoopHVAC AIRLOOP DATACENTER TOP Sum of Air Terminal Maximum Flow Rates [m3/s] 0.45731
268 AirLoopHVAC AIRLOOP DATACENTER TOP Adjusted Heating Design Air Flow Rate [m3/s] 0.45731
269 AirLoopHVAC AIRLOOP DATACENTER TOP Adjusted Cooling Design Air Flow Rate [m3/s] 0.45731
270 AirLoopHVAC AIRLOOP DATACENTER TOP Adjusted Main Design Air Flow Rate [m3/s] 0.45731
271 AirLoopHVAC AIRLOOP DATACENTER TOP User Heating Air Flow Ratio [] 1.00000
272 AirLoopHVAC AIRLOOP DATACENTER TOP Calculated Heating Air Flow Ratio [] 1.00000
273 AirLoopHVAC VAV_BOT WITH REHEAT Design Supply Air Flow Rate [m3/s] 8.63114
274 AirLoopHVAC VAV_MID WITH REHEAT Design Supply Air Flow Rate [m3/s] 79.89447
275 AirLoopHVAC VAV_TOP WITH REHEAT Design Supply Air Flow Rate [m3/s] 8.57101
276 AirLoopHVAC CAV_BAS Design Supply Air Flow Rate [m3/s] 4.94705
277 AirLoopHVAC AIRLOOP DATACENTER BOT Design Supply Air Flow Rate [m3/s] 0.47378
278 AirLoopHVAC AIRLOOP DATACENTER MID Design Supply Air Flow Rate [m3/s] 4.50464
279 AirLoopHVAC AIRLOOP DATACENTER TOP Design Supply Air Flow Rate [m3/s] 0.45731
280 Controller:OutdoorAir VAV_BOT WITH REHEAT_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 8.63114
281 HeatExchanger:AirToAir:SensibleAndLatent VAV_BOT WITH REHEAT OA HEAT RECOVERY Design Size Nominal Supply Air Flow Rate [m3/s] 2.53819
282 Coil:Cooling:Water VAV_BOT WITH REHEAT COOLING COIL Design Size Design Inlet Air Temperature [C] 27.23917
283 Coil:Cooling:Water VAV_BOT WITH REHEAT COOLING COIL Design Size Design Inlet Water Temperature [C] 6.67000
284 Coil:Cooling:Water VAV_BOT WITH REHEAT COOLING COIL Design Size Design Outlet Air Temperature [C] 10.88020
285 Coil:Cooling:Water VAV_BOT WITH REHEAT COOLING COIL Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] 1.06432E-002
286 Coil:Cooling:Water VAV_BOT WITH REHEAT COOLING COIL Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] 8.50000E-003
287 Coil:Cooling:Water VAV_BOT WITH REHEAT COOLING COIL Design Size Design Coil Load [W] 222106.68517
288 Coil:Cooling:Water VAV_BOT WITH REHEAT COOLING COIL Design Size Design Water Flow Rate [m3/s] 9.44893E-003
289 Coil:Cooling:Water VAV_BOT WITH REHEAT COOLING COIL Design Size Design Air Flow Rate [m3/s] 8.63114
290 Coil:Heating:Water VAV_BOT WITH REHEAT HEATING COIL Design Size Rated Capacity [W] 56676.83969
291 Coil:Heating:Water VAV_BOT WITH REHEAT HEATING COIL Design Size Maximum Water Flow Rate [m3/s] 4.95834E-004
292 Coil:Heating:Water VAV_BOT WITH REHEAT HEATING COIL Design Size U-Factor Times Area Value [W/K] 919.08614
293 Fan:VariableVolume VAV_BOT WITH REHEAT FAN Design Size Maximum Flow Rate [m3/s] 8.63114
294 Controller:WaterCoil VAV_BOT WITH REHEAT_COOLC_CONTROLLER Maximum Actuated Flow [m3/s] 9.44893E-003
295 Controller:WaterCoil VAV_BOT WITH REHEAT_COOLC_CONTROLLER Controller Convergence Tolerance 5.03962E-005
296 Controller:WaterCoil VAV_BOT WITH REHEAT_HEATC_CONTROLLER Maximum Actuated Flow [m3/s] 4.95834E-004
297 Controller:OutdoorAir VAV_MID WITH REHEAT_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 79.89447
298 HeatExchanger:AirToAir:SensibleAndLatent VAV_MID WITH REHEAT OA HEAT RECOVERY Design Size Nominal Supply Air Flow Rate [m3/s] 25.38195
299 Coil:Cooling:Water VAV_MID WITH REHEAT COOLING COIL Design Size Design Inlet Air Temperature [C] 27.66151
300 Coil:Cooling:Water VAV_MID WITH REHEAT COOLING COIL Design Size Design Inlet Water Temperature [C] 6.67000
301 Coil:Cooling:Water VAV_MID WITH REHEAT COOLING COIL Design Size Design Outlet Air Temperature [C] 10.88115
302 Coil:Cooling:Water VAV_MID WITH REHEAT COOLING COIL Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] 1.09160E-002
303 Coil:Cooling:Water VAV_MID WITH REHEAT COOLING COIL Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] 8.50000E-003
304 Coil:Cooling:Water VAV_MID WITH REHEAT COOLING COIL Design Size Design Coil Load [W] 2160566.93182
305 Coil:Cooling:Water VAV_MID WITH REHEAT COOLING COIL Design Size Design Water Flow Rate [m3/s] 9.19155E-002
306 Coil:Cooling:Water VAV_MID WITH REHEAT COOLING COIL Design Size Design Air Flow Rate [m3/s] 79.89447
307 Coil:Heating:Water VAV_MID WITH REHEAT HEATING COIL Design Size Rated Capacity [W] 534071.93268
308 Coil:Heating:Water VAV_MID WITH REHEAT HEATING COIL Design Size Maximum Water Flow Rate [m3/s] 4.67229E-003
309 Coil:Heating:Water VAV_MID WITH REHEAT HEATING COIL Design Size U-Factor Times Area Value [W/K] 8644.99008
310 Fan:VariableVolume VAV_MID WITH REHEAT FAN Design Size Maximum Flow Rate [m3/s] 79.89447
311 Controller:WaterCoil VAV_MID WITH REHEAT_COOLC_CONTROLLER Maximum Actuated Flow [m3/s] 9.19155E-002
312 Controller:WaterCoil VAV_MID WITH REHEAT_COOLC_CONTROLLER Controller Convergence Tolerance 5.18074E-006
313 Controller:WaterCoil VAV_MID WITH REHEAT_HEATC_CONTROLLER Maximum Actuated Flow [m3/s] 4.67229E-003
314 Controller:OutdoorAir VAV_TOP WITH REHEAT_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 8.57101
315 HeatExchanger:AirToAir:SensibleAndLatent VAV_TOP WITH REHEAT OA HEAT RECOVERY Design Size Nominal Supply Air Flow Rate [m3/s] 2.53819
316 Coil:Cooling:Water VAV_TOP WITH REHEAT COOLING COIL Design Size Design Inlet Air Temperature [C] 27.10057
317 Coil:Cooling:Water VAV_TOP WITH REHEAT COOLING COIL Design Size Design Inlet Water Temperature [C] 6.67000
318 Coil:Cooling:Water VAV_TOP WITH REHEAT COOLING COIL Design Size Design Outlet Air Temperature [C] 10.87996
319 Coil:Cooling:Water VAV_TOP WITH REHEAT COOLING COIL Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] 1.05734E-002
320 Coil:Cooling:Water VAV_TOP WITH REHEAT COOLING COIL Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] 8.50000E-003
321 Coil:Cooling:Water VAV_TOP WITH REHEAT COOLING COIL Design Size Design Coil Load [W] 217377.97565
322 Coil:Cooling:Water VAV_TOP WITH REHEAT COOLING COIL Design Size Design Water Flow Rate [m3/s] 9.24776E-003
323 Coil:Cooling:Water VAV_TOP WITH REHEAT COOLING COIL Design Size Design Air Flow Rate [m3/s] 8.57101
324 Coil:Heating:Water VAV_TOP WITH REHEAT HEATING COIL Design Size Rated Capacity [W] 56240.19418
325 Coil:Heating:Water VAV_TOP WITH REHEAT HEATING COIL Design Size Maximum Water Flow Rate [m3/s] 4.92014E-004
326 Coil:Heating:Water VAV_TOP WITH REHEAT HEATING COIL Design Size U-Factor Times Area Value [W/K] 912.06909
327 Fan:VariableVolume VAV_TOP WITH REHEAT FAN Design Size Maximum Flow Rate [m3/s] 8.57101
328 Controller:WaterCoil VAV_TOP WITH REHEAT_COOLC_CONTROLLER Maximum Actuated Flow [m3/s] 9.24776E-003
329 Controller:WaterCoil VAV_TOP WITH REHEAT_COOLC_CONTROLLER Controller Convergence Tolerance 5.14925E-005
330 Controller:WaterCoil VAV_TOP WITH REHEAT_HEATC_CONTROLLER Maximum Actuated Flow [m3/s] 4.92014E-004
331 Controller:OutdoorAir CAV_BAS_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 4.94705
332 Coil:Cooling:Water CAV_BAS COOLING COIL Design Size Design Inlet Air Temperature [C] 26.47466
333 Coil:Cooling:Water CAV_BAS COOLING COIL Design Size Design Inlet Water Temperature [C] 6.67000
334 Coil:Cooling:Water CAV_BAS COOLING COIL Design Size Design Outlet Air Temperature [C] 11.37427
335 Coil:Cooling:Water CAV_BAS COOLING COIL Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] 1.05311E-002
336 Coil:Cooling:Water CAV_BAS COOLING COIL Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] 8.50000E-003
337 Coil:Cooling:Water CAV_BAS COOLING COIL Design Size Design Coil Load [W] 118266.11561
338 Coil:Cooling:Water CAV_BAS COOLING COIL Design Size Design Water Flow Rate [m3/s] 5.03131E-003
339 Coil:Cooling:Water CAV_BAS COOLING COIL Design Size Design Air Flow Rate [m3/s] 4.94705
340 Coil:Heating:Water CAV_BAS HEATING COIL Design Size Rated Capacity [W] 239673.48975
341 Coil:Heating:Water CAV_BAS HEATING COIL Design Size Maximum Water Flow Rate [m3/s] 2.09677E-003
342 Coil:Heating:Water CAV_BAS HEATING COIL Design Size U-Factor Times Area Value [W/K] 5305.81857
343 Fan:ConstantVolume CAV_BAS FAN Design Size Maximum Flow Rate [m3/s] 4.94705
344 Controller:WaterCoil CAV_BAS_COOLC_CONTROLLER Maximum Actuated Flow [m3/s] 5.03131E-003
345 Controller:WaterCoil CAV_BAS_COOLC_CONTROLLER Controller Convergence Tolerance 9.46454E-005
346 Controller:WaterCoil CAV_BAS_HEATC_CONTROLLER Maximum Actuated Flow [m3/s] 2.09677E-003
347 Controller:OutdoorAir AIRLOOP DATACENTER BOT_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.47378
348 Controller:OutdoorAir AIRLOOP DATACENTER BOT_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 1.56328E-002
349 COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER BOT COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.47378
350 COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER BOT COOLING COIL Design Size Rated Total Cooling Capacity [W] 9347.23775
351 COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER BOT COOLING COIL Design Size Rated Sensible Cooling Capacity [W] 6482.34042
352 COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER BOT COOLING COIL Design Size Rated Water Flow Rate [m3/s] 2.28913E-004
353 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER BOT DXAC HEAT PUMP Supply Air Flow Rate [m3/s] 0.47378
354 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER BOT DXAC HEAT PUMP Supply Air Flow Rate During Heating Operation [m3/s] 0.47378
355 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER BOT DXAC HEAT PUMP Supply Air Flow Rate During Cooling Operation [m3/s] 0.47378
356 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER BOT DXAC HEAT PUMP Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.47378
357 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER BOT DXAC HEAT PUMP Nominal Heating Capacity [W] 9347.23775
358 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER BOT DXAC HEAT PUMP Nominal Cooling Capacity [W] 9347.23775
359 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER BOT DXAC HEAT PUMP Supplemental Heating Coil Nominal Capacity [W] 844.39557
360 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER BOT DXAC HEAT PUMP Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
361 Fan:OnOff AIRLOOP DATACENTER BOT SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.47378
362 COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER BOT HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.47378
363 COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER BOT HEATING COIL Design Size Rated Heating Capacity [W] 9347.23775
364 COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER BOT HEATING COIL Design Size Rated Water Flow Rate [m3/s] 2.28913E-004
365 Coil:Heating:Electric AIRLOOP DATACENTER BOT_SUPPHEATCOIL Design Size Nominal Capacity [W] 844.39557
366 Controller:OutdoorAir AIRLOOP DATACENTER MID_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 4.50464
367 Controller:OutdoorAir AIRLOOP DATACENTER MID_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 0.15633
368 COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER MID COOLING COIL Design Size Rated Air Flow Rate [m3/s] 4.50464
369 COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER MID COOLING COIL Design Size Rated Total Cooling Capacity [W] 89037.50847
370 COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER MID COOLING COIL Design Size Rated Sensible Cooling Capacity [W] 61684.77012
371 COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER MID COOLING COIL Design Size Rated Water Flow Rate [m3/s] 2.18052E-003
372 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER MID DXAC HEAT PUMP Supply Air Flow Rate [m3/s] 4.50464
373 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER MID DXAC HEAT PUMP Supply Air Flow Rate During Heating Operation [m3/s] 4.50464
374 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER MID DXAC HEAT PUMP Supply Air Flow Rate During Cooling Operation [m3/s] 4.50464
375 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER MID DXAC HEAT PUMP Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 4.50464
376 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER MID DXAC HEAT PUMP Nominal Heating Capacity [W] 89037.50847
377 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER MID DXAC HEAT PUMP Nominal Cooling Capacity [W] 89037.50847
378 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER MID DXAC HEAT PUMP Supplemental Heating Coil Nominal Capacity [W] 8443.95567
379 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER MID DXAC HEAT PUMP Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
380 Fan:OnOff AIRLOOP DATACENTER MID SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 4.50464
381 COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER MID HEATING COIL Design Size Rated Air Flow Rate [m3/s] 4.50464
382 COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER MID HEATING COIL Design Size Rated Heating Capacity [W] 89037.50847
383 COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER MID HEATING COIL Design Size Rated Water Flow Rate [m3/s] 2.18052E-003
384 Coil:Heating:Electric AIRLOOP DATACENTER MID_SUPPHEATCOIL Design Size Nominal Capacity [W] 8443.95567
385 Controller:OutdoorAir AIRLOOP DATACENTER TOP_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.45731
386 Controller:OutdoorAir AIRLOOP DATACENTER TOP_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 1.56328E-002
387 COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER TOP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.45731
388 COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER TOP COOLING COIL Design Size Rated Total Cooling Capacity [W] 9033.63895
389 COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER TOP COOLING COIL Design Size Rated Sensible Cooling Capacity [W] 6260.53242
390 COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER TOP COOLING COIL Design Size Rated Water Flow Rate [m3/s] 2.21233E-004
391 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER TOP DXAC HEAT PUMP Supply Air Flow Rate [m3/s] 0.45731
392 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER TOP DXAC HEAT PUMP Supply Air Flow Rate During Heating Operation [m3/s] 0.45731
393 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER TOP DXAC HEAT PUMP Supply Air Flow Rate During Cooling Operation [m3/s] 0.45731
394 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER TOP DXAC HEAT PUMP Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.45731
395 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER TOP DXAC HEAT PUMP Nominal Heating Capacity [W] 9033.63895
396 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER TOP DXAC HEAT PUMP Nominal Cooling Capacity [W] 9033.63895
397 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER TOP DXAC HEAT PUMP Supplemental Heating Coil Nominal Capacity [W] 844.39557
398 AirLoopHVAC:UnitaryHeatPump:WaterToAir AIRLOOP DATACENTER TOP DXAC HEAT PUMP Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
399 Fan:OnOff AIRLOOP DATACENTER TOP SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.45731
400 COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER TOP HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.45731
401 COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER TOP HEATING COIL Design Size Rated Heating Capacity [W] 9033.63895
402 COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT AIRLOOP DATACENTER TOP HEATING COIL Design Size Rated Water Flow Rate [m3/s] 2.21233E-004
403 Coil:Heating:Electric AIRLOOP DATACENTER TOP_SUPPHEATCOIL Design Size Nominal Capacity [W] 844.39557
404 Pump:VariableSpeed COOLSYS1 PUMP SECONDARY Design Flow Rate [m3/s] 0.11564
405 Pump:VariableSpeed COOLSYS1 PUMP SECONDARY Design Power Consumption [W] 23593.90412
406 PlantLoop COOLSYS1_DEMAND Maximum Loop Flow Rate [m3/s] 0.11564
407 PlantLoop COOLSYS1_DEMAND Plant Loop Volume [m3] 13.87722
408 HeatExchanger:FluidToFluid BYPASS HEAT EXCHANGER Loop Supply Side Design Fluid Flow Rate [m3/s] 0.11564
409 HeatExchanger:FluidToFluid BYPASS HEAT EXCHANGER Loop Demand Side Design Fluid Flow Rate [m3/s] 0.11564
410 HeatExchanger:FluidToFluid BYPASS HEAT EXCHANGER Heat Exchanger U-Factor Times Area Value [W/C] 485413.87647
411 HeatExchanger:FluidToFluid BYPASS HEAT EXCHANGER Loop-to-loop Temperature Difference Used to Size Heat Exchanger U-Factor Times Area Value [C] 5.60000
412 PlantLoop HEATSYS1 Maximum Loop Flow Rate [m3/s] 1.89961E-002
413 PlantLoop HEATSYS1 Plant Loop Volume [m3] 2.27954
414 Pump:VariableSpeed HEATSYS1 PUMP Design Flow Rate [m3/s] 1.89961E-002
415 Pump:VariableSpeed HEATSYS1 PUMP Design Power Consumption [W] 5664.15890
416 Pump:VariableSpeed HEATSYS1 PUMP Design Minimum Flow Rate [m3/s] 0.00000
417 Boiler:HotWater HEATSYS1 BOILER Design Size Nominal Capacity [W] 2171374.47584
418 Boiler:HotWater HEATSYS1 BOILER User-Specified Nominal Capacity [W] 2171374.48000
419 Boiler:HotWater HEATSYS1 BOILER Design Size Design Water Flow Rate [m3/s] 1.89961E-002
420 PlantLoop COOLSYS1_SUPPLY Maximum Loop Flow Rate [m3/s] 0.11564
421 PlantLoop COOLSYS1_SUPPLY Plant Loop Volume [m3] 13.87722
422 Pump:ConstantSpeed COOLSYS1 PUMP Design Flow Rate [m3/s] 0.11564
423 Pump:ConstantSpeed COOLSYS1 PUMP Design Power Consumption [W] 16334.85570
424 Chiller:Electric:ReformulatedEIR COOLSYS1 CHILLER1 Design Size Reference Chilled Water Flow Rate [m3/s] 0.11564
425 Chiller:Electric:ReformulatedEIR COOLSYS1 CHILLER1 User-Specified Reference Chilled Water Flow Rate [m3/s] 5.80700E-002
426 Chiller:Electric:ReformulatedEIR COOLSYS1 CHILLER1 Design Size Reference Capacity [W] 1368347.06005
427 Chiller:Electric:ReformulatedEIR COOLSYS1 CHILLER1 User-Specified Reference Capacity [W] 1374850.56500
428 Chiller:Electric:ReformulatedEIR COOLSYS1 CHILLER1 Design Size Reference Condenser Water Flow Rate [m3/s] 6.80363E-002
429 Chiller:Electric:ReformulatedEIR COOLSYS1 CHILLER2 Design Size Reference Chilled Water Flow Rate [m3/s] 0.11564
430 Chiller:Electric:ReformulatedEIR COOLSYS1 CHILLER2 User-Specified Reference Chilled Water Flow Rate [m3/s] 5.80700E-002
431 Chiller:Electric:ReformulatedEIR COOLSYS1 CHILLER2 Design Size Reference Capacity [W] 1368347.06005
432 Chiller:Electric:ReformulatedEIR COOLSYS1 CHILLER2 User-Specified Reference Capacity [W] 1374850.56500
433 Chiller:Electric:ReformulatedEIR COOLSYS1 CHILLER2 Design Size Reference Condenser Water Flow Rate [m3/s] 6.80363E-002
434 PlantLoop SINGLE WATER PLANT LOOP Maximum Loop Flow Rate [m3/s] 2.63067E-003
435 PlantLoop SINGLE WATER PLANT LOOP Plant Loop Volume [m3] 0.31568
436 Pump:ConstantSpeed PLANT CIRC PUMP Design Flow Rate [m3/s] 2.63067E-003
437 Pump:ConstantSpeed PLANT CIRC PUMP Design Power Consumption [W] 664.30914
438 FluidCooler:TwoSpeed CENTRAL TOWER Design Water Flow Rate [m3/s] 2.63067E-003
439 FluidCooler:TwoSpeed CENTRAL TOWER Air Flow Rate at High Fan Speed [m3/s] 35644.39112
440 FluidCooler:TwoSpeed CENTRAL TOWER Fluid cooler UA value at high fan speed based on nominal capacity input [W/K] 22092.84435
441 FluidCooler:TwoSpeed CENTRAL TOWER Air Flow Rate at Low Fan Speed [m3/s] 17822.19556
442 FluidCooler:TwoSpeed CENTRAL TOWER Fan Power at Low Fan Speed [W] 1996.19659
443 FluidCooler:TwoSpeed CENTRAL TOWER U-factor Times Area Value at Low Fan Speed [W/C] 5895.73276
444 Boiler:HotWater CENTRAL BOILER Design Size Nominal Capacity [W] 108361.02391
445 Boiler:HotWater CENTRAL BOILER User-Specified Nominal Capacity [W] 108361.02000
446 Boiler:HotWater CENTRAL BOILER Design Size Design Water Flow Rate [m3/s] 2.63067E-003
447 PlantLoop SWHSYS1 Maximum Loop Flow Rate [m3/s] 4.40000E-004
448 PlantLoop SWHSYS1 Plant Loop Volume [m3] 5.28000E-002
449 Pump:ConstantSpeed SWHSYS1 PUMP Design Flow Rate [m3/s] 4.40000E-004
450 Pump:ConstantSpeed SWHSYS1 PUMP Design Power Consumption [W] 5.95776
451 WaterHeater:Mixed SWHSYS1 WATER HEATER Use Side Design Flow Rate [m3/s] 4.40000E-004
452 CondenserLoop TOWERWATERSYS Maximum Loop Flow Rate [m3/s] 0.13607
453 CondenserLoop TOWERWATERSYS Condenser Loop Volume [m3] 16.32870
454 HeaderedPumps:VariableSpeed TOWERWATERSYS PUMP Design Flow Rate [m3/s] 0.13607
455 HeaderedPumps:VariableSpeed TOWERWATERSYS PUMP Design Power Consumption [W] 40576.31774
456 CoolingTower:VariableSpeed TOWERWATERSYS COOLTOWER 1 Design Air Flow Rate [m3/s] 54.54304
457 CoolingTower:VariableSpeed TOWERWATERSYS COOLTOWER 1 Nominal Capacity [W] 1631210.05056
458 CoolingTower:VariableSpeed TOWERWATERSYS COOLTOWER 1 Air Flow Rate in free convection regime [m3/s] 10.90861
459 CoolingTower:VariableSpeed TOWERWATERSYS COOLTOWER 1 Tower capacity in free convection regime at design conditions [W] 203901.25632
460 CoolingTower:VariableSpeed TOWERWATERSYS COOLTOWER 2 Design Air Flow Rate [m3/s] 54.54304
461 CoolingTower:VariableSpeed TOWERWATERSYS COOLTOWER 2 Nominal Capacity [W] 1631210.05056
462 CoolingTower:VariableSpeed TOWERWATERSYS COOLTOWER 2 Air Flow Rate in free convection regime [m3/s] 10.90861
463 CoolingTower:VariableSpeed TOWERWATERSYS COOLTOWER 2 Tower capacity in free convection regime at design conditions [W] 203901.25632
464 PlantEquipmentOperation:ComponentSetPoint WSHPPLANT OPERATION SCHEME Design Water Flow Rate [m3/s] Equipment # 45 7.06675E-002
465 PlantEquipmentOperation:ComponentSetPoint WSHPPLANT OPERATION SCHEME Design Water Flow Rate [m3/s] Equipment # 45 7.06675E-002


Water Heating Coil Capacity Information

Component Type Name Nominal Total Capacity {W}
1 Coil:Heating:Water CORE_BOTTOM VAV BOX REHEAT COIL 17224.72
2 Coil:Heating:Water CORE_MID VAV BOX REHEAT COIL 396068.07
3 Coil:Heating:Water CORE_TOP VAV BOX REHEAT COIL 79110.21
4 Coil:Heating:Water PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL 10485.93
5 Coil:Heating:Water PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL 7302.06
6 Coil:Heating:Water PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL 12336.14
7 Coil:Heating:Water PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL 5712.20
8 Coil:Heating:Water PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL 186102.81
9 Coil:Heating:Water PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL 122056.48
10 Coil:Heating:Water PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL 183878.03
11 Coil:Heating:Water PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL 116369.80
12 Coil:Heating:Water PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL 24597.22
13 Coil:Heating:Water PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL 16046.90
14 Coil:Heating:Water PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL 24333.10
15 Coil:Heating:Water PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL 15679.92
16 Coil:Heating:Water VAV_BOT WITH REHEAT HEATING COIL 42306.86
17 Coil:Heating:Water VAV_MID WITH REHEAT HEATING COIL 397145.33
18 Coil:Heating:Water VAV_TOP WITH REHEAT HEATING COIL 41987.38
19 Coil:Heating:Water CAV_BAS HEATING COIL 188700.33


Water Cooling Coil Capacity Information

Component Type Name Nominal Total Capacity {W} Nominal Sensible Capacity {W} Nominal Latent Capacity {W} Nominal Sensible Heat Ratio Nominal Coil UA Value {W/C} Nominal Coil Surface Area {m2}
1 Coil:Cooling:Water VAV_BOT WITH REHEAT COOLING COIL 234749.86 155263.27 79486.59 0.66 25110.49 254.68
2 Coil:Cooling:Water VAV_MID WITH REHEAT COOLING COIL 2212547.11 1455239.90 757307.21 0.66 237192.67 2405.74
3 Coil:Cooling:Water VAV_TOP WITH REHEAT COOLING COIL 231878.11 153620.05 78258.06 0.66 24794.24 251.48
4 Coil:Cooling:Water CAV_BAS COOLING COIL 129098.21 86396.10 42702.11 0.67 13461.75 136.54


Chiller Standard Rating Information

Component Type Component Name IPLV in SI Units {W/W} IPLV in IP Units {Btu/W-h}
1 Chiller:Electric:ReformulatedEIR COOLSYS1 CHILLER1 6.84 23.33
2 Chiller:Electric:ReformulatedEIR COOLSYS1 CHILLER2 6.84 23.33


Zone Surfaces

Zone Name # Surfaces
1 BASEMENT 10
2 CORE_BOTTOM 8
3 CORE_MID 7
4 CORE_TOP 7
5 PERIMETER_BOT_ZN_3 18
6 PERIMETER_BOT_ZN_2 12
7 PERIMETER_BOT_ZN_1 18
8 PERIMETER_BOT_ZN_4 12
9 PERIMETER_MID_ZN_3 9
10 PERIMETER_MID_ZN_2 8
11 PERIMETER_MID_ZN_1 9
12 PERIMETER_MID_ZN_4 8
13 PERIMETER_TOP_ZN_3 9
14 PERIMETER_TOP_ZN_2 8
15 PERIMETER_TOP_ZN_1 9
16 PERIMETER_TOP_ZN_4 8
17 GROUNDFLOOR_PLENUM 11
18 MIDFLOOR_PLENUM 11
19 TOPFLOOR_PLENUM 11
20 DATACENTER_BOT_ZN_6 6
21 DATACENTER_MID_ZN_6 6
22 DATACENTER_TOP_ZN_6 6
23 DATACENTER_BASEMENT_ZN_6 10


HeatTransfer Surface

Surface Name Surface Class Base Surface Heat Transfer Algorithm Construction Nominal U (w/o film coefs) {W/m2-K} Nominal U (with film coefs) {W/m2-K} Solar Diffusing Area (Net) {m2} Area (Gross) {m2} Area (Sunlit Calc) {m2} Azimuth {deg} Tilt {deg} ~Width {m} ~Height {m} Reveal {m} ExtBoundCondition ExtConvCoeffCalc IntConvCoeffCalc SunExposure WindExposure ViewFactorToGround ViewFactorToSky ViewFactorToGround-IR ViewFactorToSky-IR #Sides
1 BASEMENT_WALL_EAST Wall   CTF - ConductionTransferFunction BASEMENT_WALL_EAST_CFACTOR 0.940 0.824   118.87 118.87 118.87 90.00 90.00 48.74 2.44 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
2 BASEMENT_WALL_SOUTH Wall   CTF - ConductionTransferFunction BASEMENT_WALL_SOUTH_CFACTOR 0.940 0.824   139.09 139.09 139.09 180.00 90.00 57.03 2.44 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
3 BASEMENT_WALL_NORTH Wall   CTF - ConductionTransferFunction BASEMENT_WALL_NORTH_CFACTOR 0.940 0.824   139.09 139.09 139.09 0.00 90.00 57.03 2.44 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
4 BASEMENT_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   118.87 118.87 118.87 270.00 90.00 48.74 2.44 0.00 DATACENTER_BASEMENT_ZN_6_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
5 BASEMENT_FLOOR Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   2779.43 2779.43 2779.43 0.00 180.00 57.03 48.74 0.00 BASEMENT_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.00 1.00 0.00 4
6 PERIMETER_BOT_ZN_2_FLOOR-PPAUTOCREATEOTHER Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   201.98 201.98 201.98 225.00 0.00 6.47 39.59 0.00 PERIMETER_BOT_ZN_2_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
7 PERIMETER_BOT_ZN_1_FLOOR-PPAUTOCREATEOTHER Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   250.34 250.34 250.34 180.00 0.00 57.03 4.57 0.00 PERIMETER_BOT_ZN_1_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
8 CORE_BOT_ZN_5_FLOOR-PPAUTOCREATEOTHER Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   2076.77 2076.77 2076.77 180.00 0.00 52.45 39.59 0.00 CORE_BOT_ZN_5_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
9 PERIMETER_BOT_ZN_3_FLOOR-PPAUTOCREATEOTHER Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   250.34 250.34 250.34 180.00 0.00 52.45 4.57 0.00 PERIMETER_BOT_ZN_3_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
10 BASEMENT_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   7126.21 7126.21 7126.21 0.00 90.00 7126.21 1.00 0.00 BASEMENT_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
11 CORE_BOT_ZN_5_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   173.00 173.00 173.00 180.00 90.00 63.05 2.74 0.00 CORE_BOT_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
12 CORE_BOT_ZN_5_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 270.00 90.00 39.59 2.74 0.00 DATACENTER_BOT_ZN_6_WALL_EAST-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
13 CORE_BOT_ZN_5_WALL_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   173.00 173.00 173.00 0.00 90.00 63.05 2.74 0.00 CORE_BOT_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
14 CORE_BOT_ZN_5_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 90.00 90.00 39.59 2.74 0.00 CORE_BOT_ZN_5_WALL_EAST-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
15 DATACENTER_BASEMENT_ZN_6_CEILING-CORE_BOT_ZN_5-PPAUTOCREATEOTHER Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   419.30 419.30 419.30 0.00 180.00 10.59 39.59 0.00 DATACENTER_BASEMENT_ZN_6_CEILING-CORE_BOT_ZN_5 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.00 1.00 0.00 4
16 CORE_BOT_ZN_5_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   2076.82 2076.82 2076.82 0.00 180.00 52.46 39.59 0.00 CORE_BOT_ZN_5_FLOOR-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.00 1.00 0.00 4
17 CORE_BOT_ZN_5_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   2496.12 2496.12 2496.12 180.00 0.00 63.05 39.59 0.00 iz-CORE_BOT_ZN_5_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
18 CORE_BOTTOM_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   5064.65 5064.65 5064.65 0.00 90.00 5064.65 1.00 0.00 CORE_BOTTOM_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
19 CORE_MID_ZN_5_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   173.00 173.00 173.00 180.00 90.00 63.05 2.74 0.00 CORE_MID_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
20 CORE_MID_ZN_5_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 270.00 90.00 39.59 2.74 0.00 DATACENTER_MID_ZN_6_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
21 CORE_MID_ZN_5_WALL_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   173.00 173.00 173.00 0.00 90.00 63.05 2.74 0.00 CORE_MID_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
22 CORE_MID_ZN_5_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 90.00 90.00 39.59 2.74 0.00 CORE_MID_ZN_5_WALL_EAST-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
23 CORE_MID_ZN_5_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   2496.12 2496.12 2496.12 0.00 180.00 63.05 39.59 0.00 CORE_MID_ZN_5_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
24 CORE_MID_ZN_5_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   2496.12 2496.12 2496.12 180.00 0.00 63.05 39.59 0.00 iz-CORE_MID_ZN_5_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
25 CORE_MID_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   5064.65 5064.65 5064.65 0.00 90.00 5064.65 1.00 0.00 CORE_MID_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
26 CORE_TOP_ZN_5_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   173.00 173.00 173.00 180.00 90.00 63.05 2.74 0.00 CORE_BOT_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
27 CORE_TOP_ZN_5_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 270.00 90.00 39.59 2.74 0.00 DATACENTER_TOP_ZN_6_WALL_WEST-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
28 CORE_TOP_ZN_5_WALL_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   173.00 173.00 173.00 0.00 90.00 63.05 2.74 0.00 CORE_TOP_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
29 CORE_TOP_ZN_5_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 90.00 90.00 39.59 2.74 0.00 CORE_TOP_ZN_5_WALL_EAST-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
30 CORE_TOP_ZN_5_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   2496.12 2496.12 2496.12 0.00 180.00 63.05 39.59 0.00 CORE_TOP_ZN_5_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
31 CORE_TOP_ZN_5_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   2496.12 2496.12 2496.12 180.00 0.00 63.05 39.59 0.00 iz-CORE_TOP_ZN_5_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
32 CORE_TOP_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   5064.65 5064.65 5064.65 0.00 90.00 5064.65 1.00 0.00 CORE_TOP_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
33 PERIMETER_BOT_ZN_3_WALL_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 1.498 1.223   105.88 200.61 105.88 0.00 90.00 73.11 2.74 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
34 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 Window PERIMETER_BOT_ZN_3_WALL_NORTH Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_NORTH_0.25 N/A 2.408 No 17.38 17.38 17.38 0.00 90.00 13.65 1.27 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
35 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 Window PERIMETER_BOT_ZN_3_WALL_NORTH Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_NORTH_0.25 N/A 2.408 No 17.38 17.38 17.38 0.00 90.00 13.65 1.27 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
36 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 Window PERIMETER_BOT_ZN_3_WALL_NORTH Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_NORTH_0.25 N/A 2.408 No 17.38 17.38 17.38 0.00 90.00 13.65 1.27 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
37 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 Window PERIMETER_BOT_ZN_3_WALL_NORTH Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_NORTH_0.25 N/A 2.408 No 17.38 17.38 17.38 0.00 90.00 13.65 1.27 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
38 PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 Window PERIMETER_BOT_ZN_3_WALL_NORTH Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_NORTH_0.25 N/A 2.408 No 17.38 17.38 17.38 0.00 90.00 13.65 1.27 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
39 PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 Door PERIMETER_BOT_ZN_3_WALL_NORTH CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 0.00 90.00 0.91 2.13 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
40 PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 Door PERIMETER_BOT_ZN_3_WALL_NORTH CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 0.00 90.00 0.91 2.13 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
41 PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR3 Door PERIMETER_BOT_ZN_3_WALL_NORTH CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 0.00 90.00 0.91 2.13 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
42 PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR4 Door PERIMETER_BOT_ZN_3_WALL_NORTH CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 0.00 90.00 0.91 2.13 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
43 PERIMETER_BOT_ZN_3_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 225.00 90.00 6.47 2.74 0.00 PERIMETER_BOT_ZN_3_WALL_WEST-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
44 CORE_BOT_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   173.00 173.00 173.00 180.00 90.00 63.05 2.74 0.00 CORE_BOT_ZN_5_WALL_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
45 PERIMETER_BOT_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 135.00 90.00 6.47 2.74 0.00 PERIMETER_BOT_ZN_2_WALL_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
46 DATACENTER_BOT_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   2.51 2.51 2.51 180.00 90.00 0.91 2.74 0.00 DATACENTER_BOT_ZN_6_WALL_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
47 PERIMETER_BOT_ZN_3_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   250.34 250.34 250.34 0.00 180.00 52.46 6.47 0.00 PERIMETER_BOT_ZN_3_FLOOR-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
48 DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_3-PPAUTOCREATEOTHER Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   63.07 63.07 63.07 0.00 180.00 11.51 4.57 0.00 DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_3 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.00 1.00 0.00 4
49 PERIMETER_BOT_ZN_3_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   313.41 313.41 313.41 180.00 0.00 63.96 6.47 0.00 iz-PERIMETER_BOT_ZN_3_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
50 PERIMETER_BOT_ZN_3_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   626.83 626.83 626.83 0.00 90.00 626.83 1.00 0.00 PERIMETER_BOT_ZN_3_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
51 PERIMETER_BOT_ZN_2_WALL_EAST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 1.498 1.223   71.89 133.74 71.89 90.00 90.00 48.74 2.74 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
52 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 Window PERIMETER_BOT_ZN_2_WALL_EAST Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_EAST_0.25 N/A 2.408 No 19.32 19.32 19.32 90.00 90.00 15.43 1.25 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
53 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 Window PERIMETER_BOT_ZN_2_WALL_EAST Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_EAST_0.25 N/A 2.408 No 19.32 19.32 19.32 90.00 90.00 15.43 1.25 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
54 PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 Window PERIMETER_BOT_ZN_2_WALL_EAST Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_EAST_0.25 N/A 2.408 No 19.32 19.32 19.32 90.00 90.00 15.43 1.25 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
55 PERIMETER_BOT_ZN_2_WALL_EAST_DOOR1 Door PERIMETER_BOT_ZN_2_WALL_EAST CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 90.00 90.00 0.91 2.13 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
56 PERIMETER_BOT_ZN_2_WALL_EAST_DOOR2 Door PERIMETER_BOT_ZN_2_WALL_EAST CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 90.00 90.00 0.91 2.13 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
57 PERIMETER_BOT_ZN_2_WALL_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 315.00 90.00 6.47 2.74 0.00 PERIMETER_BOT_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
58 CORE_BOT_ZN_5_WALL_EAST-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 270.00 90.00 39.59 2.74 0.00 CORE_BOT_ZN_5_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
59 PERIMETER_BOT_ZN_1_WALL_EAST-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 225.00 90.00 6.47 2.74 0.00 PERIMETER_BOT_ZN_1_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
60 PERIMETER_BOT_ZN_2_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   201.98 201.98 201.98 45.00 180.00 6.47 48.74 0.00 PERIMETER_BOT_ZN_2_FLOOR-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
61 PERIMETER_BOT_ZN_2_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   201.98 201.98 201.98 225.00 0.00 6.47 39.59 0.00 iz-PERIMETER_BOT_ZN_2_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
62 PERIMETER_BOT_ZN_2_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   403.95 403.95 403.95 0.00 90.00 403.95 1.00 0.00 PERIMETER_BOT_ZN_2_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
63 PERIMETER_BOT_ZN_1_WALL_SOUTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 1.498 1.223   105.88 200.61 105.88 180.00 90.00 73.11 2.74 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
64 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 Window PERIMETER_BOT_ZN_1_WALL_SOUTH Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_SOUTH_0.25 N/A 2.408 No 17.38 17.38 17.38 180.00 90.00 13.65 1.27 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
65 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 Window PERIMETER_BOT_ZN_1_WALL_SOUTH Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_SOUTH_0.25 N/A 2.408 No 17.38 17.38 17.38 180.00 90.00 13.65 1.27 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
66 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 Window PERIMETER_BOT_ZN_1_WALL_SOUTH Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_SOUTH_0.25 N/A 2.408 No 17.38 17.38 17.38 180.00 90.00 13.65 1.27 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
67 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 Window PERIMETER_BOT_ZN_1_WALL_SOUTH Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_SOUTH_0.25 N/A 2.408 No 17.38 17.38 17.38 180.00 90.00 13.65 1.27 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
68 PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 Window PERIMETER_BOT_ZN_1_WALL_SOUTH Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_SOUTH_0.25 N/A 2.408 No 17.38 17.38 17.38 180.00 90.00 13.65 1.27 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
69 PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 Door PERIMETER_BOT_ZN_1_WALL_SOUTH CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 180.00 90.00 0.91 2.13 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
70 PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 Door PERIMETER_BOT_ZN_1_WALL_SOUTH CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 180.00 90.00 0.91 2.13 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
71 PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR3 Door PERIMETER_BOT_ZN_1_WALL_SOUTH CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 180.00 90.00 0.91 2.13 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
72 PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR4 Door PERIMETER_BOT_ZN_1_WALL_SOUTH CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 180.00 90.00 0.91 2.13 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
73 PERIMETER_BOT_ZN_1_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 45.00 90.00 6.47 2.74 0.00 PERIMETER_BOT_ZN_1_WALL_EAST-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
74 DATACENTER_BOT_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   2.51 2.51 2.51 0.00 90.00 0.91 2.74 0.00 DATACENTER_BOT_ZN_6_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
75 PERIMETER_BOT_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 315.00 90.00 6.47 2.74 0.00 PERIMETER_BOT_ZN_4_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
76 CORE_BOT_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   173.00 173.00 173.00 0.00 90.00 63.05 2.74 0.00 CORE_BOT_ZN_5_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
77 DATACENTER_BASEMENT_ZN_6-PERIMETER_BOT_ZN_1-PPAUTOCREATEOTHER Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   63.07 63.07 63.07 0.00 180.00 16.08 4.57 0.00 DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.00 1.00 0.00 4
78 PERIMETER_BOT_ZN_1_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   250.35 250.35 250.35 0.00 180.00 57.03 6.47 0.00 PERIMETER_BOT_ZN_1_FLOOR-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.00 1.00 0.00 4
79 PERIMETER_BOT_ZN_1_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   313.42 313.42 313.42 180.00 0.00 73.11 6.47 0.00 iz-PERIMETER_BOT_ZN_1_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
80 PERIMETER_BOT_ZN_1_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   626.84 626.84 626.84 0.00 90.00 626.84 1.00 0.00 PERIMETER_BOT_ZN_1_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
81 PERIMETER_BOT_ZN_4_WALL_WEST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 1.498 1.223   71.89 133.74 71.89 270.00 90.00 48.74 2.74 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
82 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 Window PERIMETER_BOT_ZN_4_WALL_WEST Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_WEST_0.25 N/A 2.408 No 19.32 19.32 19.32 270.00 90.00 15.43 1.25 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
83 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 Window PERIMETER_BOT_ZN_4_WALL_WEST Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_WEST_0.25 N/A 2.408 No 19.32 19.32 19.32 270.00 90.00 15.43 1.25 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
84 PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 Window PERIMETER_BOT_ZN_4_WALL_WEST Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_WEST_0.25 N/A 2.408 No 19.32 19.32 19.32 270.00 90.00 15.43 1.25 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
85 PERIMETER_BOT_ZN_4_WALL_WEST_DOOR1 Door PERIMETER_BOT_ZN_4_WALL_WEST CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 270.00 90.00 0.91 2.13 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
86 PERIMETER_BOT_ZN_4_WALL_WEST_DOOR2 Door PERIMETER_BOT_ZN_4_WALL_WEST CTF - ConductionTransferFunction SWINGING DOOR_CON 2.101 2.101   1.95 1.95 1.95 270.00 90.00 0.91 2.13 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
87 PERIMETER_BOT_ZN_4_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 135.00 90.00 6.47 2.74 0.00 PERIMETER_BOT_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
88 DATACENTER_BOT_ZN_6_WALL_WEST-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 90.00 90.00 39.59 2.74 0.00 DATACENTER_BOT_ZN_6_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
89 PERIMETER_BOT_ZN_3_WALL_WEST-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 45.00 90.00 6.47 2.74 0.00 PERIMETER_BOT_ZN_3_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
90 PERIMETER_BOT_ZN_4_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   201.98 201.98 201.98 315.00 180.00 6.47 39.59 0.00 PERIMETER_BOT_ZN_4_FLOOR-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.00 1.00 0.00 4
91 PERIMETER_BOT_ZN_4_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   201.98 201.98 201.98 135.00 0.00 6.47 48.74 0.00 iz-PERIMETER_BOT_ZN_4_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
92 PERIMETER_BOT_ZN_4_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   403.95 403.95 403.95 0.00 90.00 403.95 1.00 0.00 PERIMETER_BOT_ZN_4_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
93 PERIMETER_MID_ZN_3_WALL_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_MID 1.416 1.168   113.68 200.61 113.68 0.00 90.00 73.11 2.74 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
94 PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW Window PERIMETER_MID_ZN_3_WALL_NORTH Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_NORTH_0.25 N/A 2.408 No 86.92 86.92 86.92 0.00 90.00 73.11 1.19 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
95 PERIMETER_MID_ZN_3_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 225.00 90.00 6.47 2.74 0.00 PERIMETER_MID_ZN_3_WALL_WEST-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
96 CORE_MID_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   173.00 173.00 173.00 180.00 90.00 63.05 2.74 0.00 CORE_MID_ZN_5_WALL_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
97 PERIMETER_MID_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 135.00 90.00 6.47 2.74 0.00 PERIMETER_MID_ZN_2_WALL_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
98 DATACENTER_MID_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   2.51 2.51 2.51 180.00 90.00 0.91 2.74 0.00 DATACENTER_MID_ZN_6_WALL_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
99 PERIMETER_MID_ZN_3_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   313.41 313.41 313.41 0.00 180.00 63.96 6.47 0.00 PERIMETER_MID_ZN_3_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
100 PERIMETER_MID_ZN_3_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   313.41 313.41 313.41 180.00 0.00 63.96 6.47 0.00 iz-PERIMETER_MID_ZN_3_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
101 PERIMETER_MID_ZN_3_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   626.83 626.83 626.83 0.00 90.00 626.83 1.00 0.00 PERIMETER_MID_ZN_3_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
102 PERIMETER_MID_ZN_2_WALL_EAST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_MID 1.416 1.168   75.79 133.74 75.79 90.00 90.00 48.74 2.74 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
103 PERIMETER_MID_ZN_2_WALL_EAST_WINDOW Window PERIMETER_MID_ZN_2_WALL_EAST Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_EAST_0.25 N/A 2.408 No 57.95 57.95 57.95 90.00 90.00 48.74 1.19 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
104 PERIMETER_MID_ZN_2_WALL_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 315.00 90.00 6.47 2.74 0.00 PERIMETER_MID_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
105 CORE_MID_ZN_5_WALL_EAST-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 270.00 90.00 39.59 2.74 0.00 CORE_MID_ZN_5_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
106 PERIMETER_MID_ZN_1_WALL_EAST-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 225.00 90.00 6.47 2.74 0.00 PERIMETER_MID_ZN_1_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
107 PERIMETER_MID_ZN_2_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   201.98 201.98 201.98 45.00 180.00 6.47 48.74 0.00 PERIMETER_MID_ZN_2_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
108 PERIMETER_MID_ZN_2_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   201.98 201.98 201.98 225.00 0.00 6.47 39.59 0.00 iz-PERIMETER_MID_ZN_2_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
109 PERIMETER_MID_ZN_2_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   403.95 403.95 403.95 0.00 90.00 403.95 1.00 0.00 PERIMETER_MID_ZN_2_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
110 PERIMETER_MID_ZN_1_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 45.00 90.00 6.47 2.74 0.00 PERIMETER_MID_ZN_1_WALL_EAST-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
111 PERIMETER_MID_ZN_1_WALL_SOUTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_MID 1.416 1.168   113.68 200.61 113.68 180.00 90.00 73.11 2.74 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
112 PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW Window PERIMETER_MID_ZN_1_WALL_SOUTH Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_SOUTH_0.25 N/A 2.408 No 86.92 86.92 86.92 180.00 90.00 73.11 1.19 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
113 DATACENTER_MID_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   2.51 2.51 2.51 0.00 90.00 0.91 2.74 0.00 DATACENTER_MID_ZN_6_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
114 PERIMETER_MID_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 315.00 90.00 6.47 2.74 0.00 PERIMETER_MID_ZN_4_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
115 CORE_MID_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   173.00 173.00 173.00 0.00 90.00 63.05 2.74 0.00 CORE_MID_ZN_5_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
116 PERIMETER_MID_ZN_1_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   313.42 313.42 313.42 0.00 180.00 73.11 6.47 0.00 PERIMETER_MID_ZN_1_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
117 PERIMETER_MID_ZN_1_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   313.42 313.42 313.42 180.00 0.00 73.11 6.47 0.00 iz-PERIMETER_MID_ZN_1_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
118 PERIMETER_MID_ZN_1_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   626.84 626.84 626.84 0.00 90.00 626.84 1.00 0.00 PERIMETER_MID_ZN_1_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
119 PERIMETER_MID_ZN_4_WALL_WEST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_MID 1.416 1.168   75.79 133.74 75.79 270.00 90.00 48.74 2.74 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
120 PERIMETER_MID_ZN_4_WALL_WEST_WINDOW Window PERIMETER_MID_ZN_4_WALL_WEST Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_WEST_0.25 N/A 2.408 No 57.95 57.95 57.95 270.00 90.00 48.74 1.19 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
121 PERIMETER_MID_ZN_4_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 135.00 90.00 6.47 2.74 0.00 PERIMETER_MID_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
122 DATACENTER_MID_ZN_6_WALL_WEST-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 90.00 90.00 39.59 2.74 0.00 DATACENTER_MID_ZN_6_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
123 PERIMETER_MID_ZN_3_WALL_WEST-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 45.00 90.00 6.47 2.74 0.00 PERIMETER_MID_ZN_3_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
124 PERIMETER_MID_ZN_4_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   201.98 201.98 201.98 315.00 180.00 6.47 39.59 0.00 PERIMETER_MID_ZN_4_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
125 PERIMETER_MID_ZN_4_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   201.98 201.98 201.98 135.00 0.00 6.47 48.74 0.00 iz-PERIMETER_MID_ZN_4_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
126 PERIMETER_MID_ZN_4_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   403.95 403.95 403.95 0.00 90.00 403.95 1.00 0.00 PERIMETER_MID_ZN_4_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
127 PERIMETER_TOP_ZN_3_WALL_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 1.867 1.459   113.68 200.61 113.68 0.00 90.00 73.11 2.74 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
128 PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW Window PERIMETER_TOP_ZN_3_WALL_NORTH Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_NORTH_0.25 N/A 2.408 No 86.92 86.92 86.92 0.00 90.00 73.11 1.19 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
129 PERIMETER_TOP_ZN_3_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 225.00 90.00 6.47 2.74 0.00 PERIMETER_TOP_ZN_3_WALL_WEST-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
130 CORE_TOP_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   173.00 173.00 173.00 180.00 90.00 63.05 2.74 0.00 CORE_TOP_ZN_5_WALL_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
131 PERIMETER_TOP_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 135.00 90.00 6.47 2.74 0.00 PERIMETER_TOP_ZN_2_WALL_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
132 DATACENTER_TOP_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   2.51 2.51 2.51 180.00 90.00 0.91 2.74 0.00 DATACENTER_TOP_ZN_6_WALL_NORTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
133 PERIMETER_TOP_ZN_3_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   313.41 313.41 313.41 0.00 180.00 63.96 6.47 0.00 PERIMETER_TOP_ZN_3_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
134 PERIMETER_TOP_ZN_3_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   313.41 313.41 313.41 180.00 0.00 63.96 6.47 0.00 iz-PERIMETER_TOP_ZN_3_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
135 PERIMETER_TOP_ZN_3_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   626.83 626.83 626.83 0.00 90.00 626.83 1.00 0.00 PERIMETER_TOP_ZN_3_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
136 PERIMETER_TOP_ZN_2_WALL_EAST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 1.867 1.459   75.79 133.74 75.79 90.00 90.00 48.74 2.74 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
137 PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW Window PERIMETER_TOP_ZN_2_WALL_EAST Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_EAST_0.25 N/A 2.408 No 57.95 57.95 57.95 90.00 90.00 48.74 1.19 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
138 PERIMETER_TOP_ZN_2_WALL_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 315.00 90.00 6.47 2.74 0.00 PERIMETER_TOP_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
139 CORE_TOP_ZN_5_WALL_EAST-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 270.00 90.00 39.59 2.74 0.00 CORE_TOP_ZN_5_WALL_EAST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
140 INT-PER3S-NE-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 225.00 90.00 6.47 2.74 0.00 INT-PER3S-NE Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
141 PERIMETER_TOP_ZN_2_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   201.98 201.98 201.98 45.00 180.00 6.47 48.74 0.00 PERIMETER_TOP_ZN_2_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
142 PERIMETER_TOP_ZN_2_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   201.98 201.98 201.98 225.00 0.00 6.47 39.59 0.00 iz-PERIMETER_TOP_ZN_2_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
143 PERIMETER_TOP_ZN_2_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   403.95 403.95 403.95 0.00 90.00 403.95 1.00 0.00 PERIMETER_TOP_ZN_2_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
144 PERIMETER_TOP_ZN_1_WALL_SOUTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 1.867 1.459   113.68 200.61 113.68 180.00 90.00 73.11 2.74 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
145 PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW Window PERIMETER_TOP_ZN_1_WALL_SOUTH Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_SOUTH_0.25 N/A 2.408 No 86.92 86.92 86.92 180.00 90.00 73.11 1.19 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
146 INT-PER3S-NE Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 45.00 90.00 6.47 2.74 0.00 INT-PER3S-NE-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
147 DATACENTER_TOP_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   2.51 2.51 2.51 0.00 90.00 0.91 2.74 0.00 DATACENTER_TOP_ZN_6_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
148 PERIMETER_TOP_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 315.00 90.00 6.47 2.74 0.00 PERIMETER_TOP_ZN_4_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
149 CORE_TOP_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   173.00 173.00 173.00 0.00 90.00 63.05 2.74 0.00 CORE_TOP_ZN_5_WALL_SOUTH Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
150 PERIMETER_TOP_ZN_1_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   313.42 313.42 313.42 0.00 180.00 73.11 6.47 0.00 PERIMETER_TOP_ZN_1_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
151 PERIMETER_TOP_ZN_1_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   313.42 313.42 313.42 180.00 0.00 73.11 6.47 0.00 iz-PERIMETER_TOP_ZN_1_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
152 PERIMETER_TOP_ZN_1_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   626.84 626.84 626.84 0.00 90.00 626.84 1.00 0.00 PERIMETER_TOP_ZN_1_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
153 PERIMETER_TOP_ZN_4_WALL_WEST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 1.867 1.459   75.79 133.74 75.79 270.00 90.00 48.74 2.74 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
154 PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW Window PERIMETER_TOP_ZN_4_WALL_WEST Window5 Detailed Fenestration WINDOW_U_0.4237_SHGC_WEST_0.25 N/A 2.408 No 57.95 57.95 57.95 270.00 90.00 48.74 1.19 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
155 PERIMETER_TOP_ZN_4_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 135.00 90.00 6.47 2.74 0.00 PERIMETER_TOP_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
156 DATACENTER_TOP_ZN_6_WALL_WEST-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 90.00 90.00 39.59 2.74 0.00 DATACENTER_TOP_ZN_6_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
157 PERIMETER_TOP_ZN_3_WALL_WEST-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   17.75 17.75 17.75 45.00 90.00 6.47 2.74 0.00 PERIMETER_TOP_ZN_3_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
158 PERIMETER_TOP_ZN_4_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   201.98 201.98 201.98 315.00 180.00 6.47 39.59 0.00 PERIMETER_TOP_ZN_4_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
159 PERIMETER_TOP_ZN_4_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   201.98 201.98 201.98 135.00 0.00 6.47 48.74 0.00 iz-PERIMETER_TOP_ZN_4_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
160 PERIMETER_TOP_ZN_4_INTERNALMASS_1 Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   403.95 403.95 403.95 0.00 90.00 403.95 1.00 0.00 PERIMETER_TOP_ZN_4_INTERNALMASS_1 Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
161 GROUNDFLOOR_PLENUM_WALL_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 1.498 1.223   89.13 89.13 89.13 0.00 90.00 73.11 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
162 GROUNDFLOOR_PLENUM_WEST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 1.498 1.223   59.42 59.42 59.42 270.00 90.00 48.74 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
163 GROUNDFLOOR_PLENUM_WALL_SOUTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 1.498 1.223   89.13 89.13 89.13 180.00 90.00 73.11 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
164 GROUNDFLOOR_PLENUM_WALL_EAST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 1.498 1.223   59.42 59.42 59.42 90.00 90.00 48.74 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
165 iz-CORE_BOT_ZN_5_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   2496.12 2496.12 2496.12 0.00 180.00 63.05 39.59 0.00 CORE_BOT_ZN_5_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
166 iz-PERIMETER_BOT_ZN_3_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   313.41 313.41 313.41 0.00 180.00 63.96 6.47 0.00 PERIMETER_BOT_ZN_3_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
167 iz-PERIMETER_BOT_ZN_2_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   201.98 201.98 201.98 45.00 180.00 6.47 48.74 0.00 PERIMETER_BOT_ZN_2_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
168 iz-PERIMETER_BOT_ZN_1_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   313.42 313.42 313.42 0.00 180.00 73.11 6.47 0.00 PERIMETER_BOT_ZN_1_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
169 iz-PERIMETER_BOT_ZN_4_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   201.98 201.98 201.98 315.00 180.00 6.47 39.59 0.00 PERIMETER_BOT_ZN_4_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
170 iz-DATACENTER_BOT_ZN_6_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   36.20 36.20 36.20 0.00 180.00 0.91 39.59 0.00 DATACENTER_BOT_ZN_6_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
171 GROUNDFLOOR_PLENUM_CEILING Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   3563.11 3563.11 3563.11 180.00 0.00 73.11 48.74 0.00 GROUNDFLOOR_PLENUM_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
172 MIDFLOOR_PLENUM_WALL_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_MID 1.416 1.168   89.13 89.13 89.13 0.00 90.00 73.11 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
173 MIDFLOOR_PLENUM_WALL_WEST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_MID 1.416 1.168   59.42 59.42 59.42 270.00 90.00 48.74 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
174 MIDFLOOR_PLENUM_WALL_SOUTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_MID 1.416 1.168   89.13 89.13 89.13 180.00 90.00 73.11 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
175 MIDFLOOR_PLENUM_WALL_EAST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_MID 1.416 1.168   59.42 59.42 59.42 90.00 90.00 48.74 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
176 iz-CORE_MID_ZN_5_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   2496.12 2496.12 2496.12 0.00 180.00 63.05 39.59 0.00 CORE_MID_ZN_5_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
177 iz-PERIMETER_MID_ZN_3_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   313.41 313.41 313.41 0.00 180.00 63.96 6.47 0.00 PERIMETER_MID_ZN_3_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
178 iz-PERIMETER_MID_ZN_2_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   201.98 201.98 201.98 45.00 180.00 6.47 48.74 0.00 PERIMETER_MID_ZN_2_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
179 iz-PERIMETER_MID_ZN_1_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   313.42 313.42 313.42 0.00 180.00 73.11 6.47 0.00 PERIMETER_MID_ZN_1_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
180 iz-PERIMETER_MID_ZN_4_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   201.98 201.98 201.98 315.00 180.00 6.47 39.59 0.00 PERIMETER_MID_ZN_4_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
181 iz-DATACENTER_MID_ZN_6_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   36.20 36.20 36.20 0.00 180.00 0.91 39.59 0.00 DATACENTER_MID_ZN_6_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
182 MIDFLOOR_PLENUM_CEILING Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   3563.11 3563.11 3563.11 180.00 0.00 73.11 48.74 0.00 MIDFLOOR_PLENUM_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
183 TOPFLOOR_PLENUM_WALL_NORTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 1.867 1.459   89.13 89.13 89.13 180.00 90.00 73.11 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
184 TOPFLOOR_PLENUM_WALL_EAST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 1.867 1.459   59.42 59.42 59.42 90.00 90.00 48.74 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
185 TOPFLOOR_PLENUM_WALL_WEST Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 1.867 1.459   59.42 59.42 59.42 270.00 90.00 48.74 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
186 TOPFLOOR_PLENUM_WALL_SOUTH Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 1.867 1.459   89.13 89.13 89.13 0.00 90.00 73.11 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
187 iz-CORE_TOP_ZN_5_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   2496.12 2496.12 2496.12 0.00 180.00 63.05 39.59 0.00 CORE_TOP_ZN_5_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
188 iz-PERIMETER_TOP_ZN_3_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   313.41 313.41 313.41 0.00 180.00 63.96 6.47 0.00 PERIMETER_TOP_ZN_3_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
189 iz-PERIMETER_TOP_ZN_2_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   201.98 201.98 201.98 45.00 180.00 6.47 48.74 0.00 PERIMETER_TOP_ZN_2_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
190 iz-PERIMETER_TOP_ZN_1_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   313.42 313.42 313.42 0.00 180.00 73.11 6.47 0.00 PERIMETER_TOP_ZN_1_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
191 iz-PERIMETER_TOP_ZN_4_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   201.98 201.98 201.98 315.00 180.00 6.47 39.59 0.00 PERIMETER_TOP_ZN_4_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
192 iz-DATACENTER_TOP_ZN_6_CEILING Floor   CTF - ConductionTransferFunction DROPCEILING 4.488 2.147   36.20 36.20 36.20 0.00 180.00 0.91 39.59 0.00 DATACENTER_TOP_ZN_6_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
193 BUILDING_ROOF Roof   CTF - ConductionTransferFunction NONRES_ROOF 0.228 0.219   3563.11 3563.11 3563.11 180.00 0.00 73.11 48.74 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 4
194 DATACENTER_BOT_ZN_6_WALL_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   2.51 2.51 2.51 0.00 90.00 0.91 2.74 0.00 DATACENTER_BOT_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
195 DATACENTER_BOT_ZN_6_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   2.51 2.51 2.51 180.00 90.00 0.91 2.74 0.00 DATACENTER_BOT_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
196 DATACENTER_BOT_ZN_6_WALL_EAST-PPAUTOCREATEOTHER Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 90.00 90.00 39.59 2.74 0.00 CORE_BOT_ZN_5_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
197 DATACENTER_BOT_ZN_6_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 270.00 90.00 39.59 2.74 0.00 DATACENTER_BOT_ZN_6_WALL_WEST-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
198 DATACENTER_BOT_ZN_6_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   36.20 36.20 36.20 0.00 180.00 0.91 39.59 0.00 DATACENTER_BOT_ZN_6_FLOOR-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.00 1.00 0.00 4
199 DATACENTER_BOT_ZN_6_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   36.20 36.20 36.20 180.00 0.00 0.91 39.59 0.00 iz-DATACENTER_BOT_ZN_6_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
200 DATACENTER_MID_ZN_6_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 270.00 90.00 39.59 2.74 0.00 DATACENTER_MID_ZN_6_WALL_WEST-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
201 DATACENTER_MID_ZN_6_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   2.51 2.51 2.51 180.00 90.00 0.91 2.74 0.00 DATACENTER_MID_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
202 DATACENTER_MID_ZN_6_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 90.00 90.00 39.59 2.74 0.00 CORE_MID_ZN_5_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
203 DATACENTER_MID_ZN_6_WALL_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   2.51 2.51 2.51 0.00 90.00 0.91 2.74 0.00 DATACENTER_MID_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
204 DATACENTER_MID_ZN_6_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   36.20 36.20 36.20 0.00 180.00 0.91 39.59 0.00 DATACENTER_MID_ZN_6_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.00 1.00 0.00 4
205 DATACENTER_MID_ZN_6_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   36.20 36.20 36.20 180.00 0.00 0.91 39.59 0.00 iz-DATACENTER_MID_ZN_6_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
206 DATACENTER_TOP_ZN_6_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 90.00 90.00 39.59 2.74 0.00 CORE_TOP_ZN_5_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
207 DATACENTER_TOP_ZN_6_WALL_WEST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   108.64 108.64 108.64 270.00 90.00 39.59 2.74 0.00 DATACENTER_TOP_ZN_6_WALL_WEST-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
208 DATACENTER_TOP_ZN_6_WALL_SOUTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   2.51 2.51 2.51 180.00 90.00 0.91 2.74 0.00 DATACENTER_TOP_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
209 DATACENTER_TOP_ZN_6_WALL_NORTH Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   2.51 2.51 2.51 0.00 90.00 0.91 2.74 0.00 DATACENTER_TOP_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
210 DATACENTER_TOP_ZN_6_FLOOR Floor   CTF - ConductionTransferFunction INT_SLAB_FLOOR 3.839 1.986   36.20 36.20 36.20 0.00 180.00 0.91 39.59 0.00 DATACENTER_TOP_ZN_6_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.00 1.00 0.00 4
211 DATACENTER_TOP_ZN_6_CEILING Roof   CTF - ConductionTransferFunction DROPCEILING 4.488 2.432   36.20 36.20 36.20 180.00 0.00 0.91 39.59 0.00 iz-DATACENTER_TOP_ZN_6_CEILING Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
212 DATACENTER_BASEMENT_ZN_6_WALL_NORTH Wall   CTF - ConductionTransferFunction DATACENTER_BASEMENT_ZN_6_WALL_NORTH_CFACTOR 0.940 0.824   39.22 39.22 39.22 0.00 90.00 16.08 2.44 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
213 DATACENTER_BASEMENT_ZN_6_WALL_SOUTH Wall   CTF - ConductionTransferFunction DATACENTER_BASEMENT_ZN_6_WALL_SOUTH_CFACTOR 0.940 0.824   39.22 39.22 39.22 180.00 90.00 16.08 2.44 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
214 DATACENTER_BASEMENT_ZN_6_WALL_WEST Wall   CTF - ConductionTransferFunction DATACENTER_BASEMENT_ZN_6_WALL_WEST_CFACTOR 0.940 0.824   118.87 118.87 118.87 270.00 90.00 48.74 2.44 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
215 DATACENTER_BASEMENT_ZN_6_WALL_EAST Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   118.87 118.87 118.87 90.00 90.00 48.74 2.44 0.00 BASEMENT_WALL_WEST Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 0.50 0.50 4
216 DATACENTER_BASEMENT_ZN_6_FLOOR Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   783.68 783.68 783.68 0.00 180.00 16.08 48.74 0.00 DATACENTER_BASEMENT_ZN_6_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.00 1.00 0.00 4
217 DATACENTER_BOT_ZN_6_FLOOR-PPAUTOCREATEOTHER Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   36.20 36.20 36.20 180.00 0.00 0.91 39.59 0.00 DATACENTER_BOT_ZN_6_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
218 DATACENTER_BASEMENT_ZN_6_CEILING-CORE_BOT_ZN_5 Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   419.35 419.35 419.35 180.00 0.00 10.59 39.59 0.00 DATACENTER_BASEMENT_ZN_6_CEILING-CORE_BOT_ZN_5-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
219 PERIMETER_BOT_ZN_4_FLOOR-PPAUTOCREATEOTHER Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   201.98 201.98 201.98 135.00 0.00 6.47 48.74 0.00 PERIMETER_BOT_ZN_4_FLOOR Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
220 DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_1 Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   63.08 63.08 63.08 180.00 0.00 16.08 6.47 0.00 DATACENTER_BASEMENT_ZN_6-PERIMETER_BOT_ZN_1-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
221 DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_3 Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   63.07 63.07 63.07 180.00 0.00 11.51 6.47 0.00 DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_3-PPAUTOCREATEOTHER Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4


Environment

Environment Name Environment Type Start Date End Date Start DayOfWeek Duration {#days} Source:Start DayOfWeek Use Daylight Saving Use Holidays Apply Weekend Holiday Rule Use Rain Values Use Snow Values Sky Temperature Model
1 RUNPERIOD 1 WeatherFileRunPeriod 01/01/2017 12/31/2017 Sunday 365 Use RunPeriod Specified Day No No No Yes Yes Clark and Allen


Environment:Special Days

Special Day Name Special Day Type Source Start Date Duration {#days}
1 NEW YEARS DAY Holiday InputFile 01/01 1Environment:Special Days


Environment:Daylight Saving

Daylight Saving Indicator Source Start Date End Date
1 Yes InputFile 03/12 11/05


Tabular Report

Style Unit Conversion
1 Commaandhtml commaandhtml


Warmup Convergence Information

Zone Name Environment Type/Name Average Warmup Temperature Difference {deltaC} Std Dev Warmup Temperature Difference {deltaC} Max Temperature Pass/Fail Convergence Min Temperature Pass/Fail Convergence Average Warmup Load Difference {W} Std Dev Warmup Load Difference {W} Heating Load Pass/Fail Convergence Cooling Load Pass/Fail Convergence
1 BASEMENT RunPeriod: RUNPERIOD 1 0.3441377129 0.2767571170 Pass Pass 1.2843180464 2.3143958439 Fail Fail
2 CORE_BOTTOM RunPeriod: RUNPERIOD 1 3.1423724014E-003 5.4258405557E-003 Pass Pass 0.0000000000 0.0000000000 Pass Pass
3 CORE_MID RunPeriod: RUNPERIOD 1 3.9112503505E-003 5.9776342284E-003 Pass Pass 0.0000000000 0.0000000000 Pass Pass
4 CORE_TOP RunPeriod: RUNPERIOD 1 1.8086222144E-002 2.2480899878E-002 Pass Pass 3.0005310094E-002 0.1614021399 Pass Pass
5 PERIMETER_BOT_ZN_3 RunPeriod: RUNPERIOD 1 1.9367665206E-002 1.7871174999E-002 Pass Pass 0.0000000000 0.0000000000 Pass Pass
6 PERIMETER_BOT_ZN_2 RunPeriod: RUNPERIOD 1 1.9719773266E-002 1.9122147973E-002 Pass Pass 0.0000000000 0.0000000000 Pass Pass
7 PERIMETER_BOT_ZN_1 RunPeriod: RUNPERIOD 1 1.9747720327E-002 1.8256970867E-002 Pass Pass 0.0000000000 0.0000000000 Pass Pass
8 PERIMETER_BOT_ZN_4 RunPeriod: RUNPERIOD 1 1.9634633841E-002 1.7981485914E-002 Pass Pass 0.0000000000 0.0000000000 Pass Pass
9 PERIMETER_MID_ZN_3 RunPeriod: RUNPERIOD 1 2.2168052804E-002 1.9044146272E-002 Pass Pass 0.0000000000 0.0000000000 Pass Pass
10 PERIMETER_MID_ZN_2 RunPeriod: RUNPERIOD 1 2.2923970959E-002 2.0435462880E-002 Pass Pass 0.0000000000 0.0000000000 Pass Pass
11 PERIMETER_MID_ZN_1 RunPeriod: RUNPERIOD 1 2.3796186077E-002 2.1417687955E-002 Pass Pass 0.0000000000 0.0000000000 Pass Pass
12 PERIMETER_MID_ZN_4 RunPeriod: RUNPERIOD 1 2.3157890412E-002 1.9371364425E-002 Pass Pass 0.0000000000 0.0000000000 Pass Pass
13 PERIMETER_TOP_ZN_3 RunPeriod: RUNPERIOD 1 5.5141413442E-002 9.9175440785E-002 Pass Pass 2.1387008868 25.0368391802 Fail Pass
14 PERIMETER_TOP_ZN_2 RunPeriod: RUNPERIOD 1 5.3708098498E-002 9.2688913150E-002 Pass Pass 1.8643786393 21.7722673283 Fail Pass
15 PERIMETER_TOP_ZN_1 RunPeriod: RUNPERIOD 1 4.7498767699E-002 7.3432842118E-002 Pass Pass 3.0282762933 35.7097724943 Fail Pass
16 PERIMETER_TOP_ZN_4 RunPeriod: RUNPERIOD 1 2.6945362166E-002 2.0474938841E-002 Pass Pass 3.1321586453E-002 0.1730611317 Pass Pass
17 GROUNDFLOOR_PLENUM RunPeriod: RUNPERIOD 1 2.1909561472E-003 1.7041293308E-003 Pass Pass 0.0000000000 0.0000000000 Pass Pass
18 MIDFLOOR_PLENUM RunPeriod: RUNPERIOD 1 2.6631228437E-003 2.0057118855E-003 Pass Pass 0.0000000000 0.0000000000 Pass Pass
19 TOPFLOOR_PLENUM RunPeriod: RUNPERIOD 1 3.9890317391E-002 3.9917809089E-002 Pass Pass 3.2891892825E-002 0.1792248980 Pass Pass
20 DATACENTER_BOT_ZN_6 RunPeriod: RUNPERIOD 1 8.1571152989E-006 9.3592756515E-006 Pass Pass 1.6958215708E-003 1.1316666102E-003 Pass Pass
21 DATACENTER_MID_ZN_6 RunPeriod: RUNPERIOD 1 6.9775744406E-006 6.5520202010E-006 Pass Pass 1.2015819367E-002 8.7322767917E-003 Pass Pass
22 DATACENTER_TOP_ZN_6 RunPeriod: RUNPERIOD 1 1.4187410421E-002 1.0478536317E-002 Pass Pass 3.5129563330E-003 4.0563863563E-003 Pass Pass
23 DATACENTER_BASEMENT_ZN_6 RunPeriod: RUNPERIOD 1 2.5411771453E-015 2.6034115468E-015 Pass Pass 3.4201012850E-005 1.0643366373E-004 Pass Pass



Table of Contents

Report: Annual Heat Emissions Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Heat Emission by Components

Envelope Convection Zone Exfiltration Zone Exhaust Air HVAC Relief Air HVAC Reject Heat Total
Heat Emissions [GJ] 5614.95 28.38 0.00 10781.89 12096.94 28522.14



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB -6.30 0.00 -6.30 Wetbulb [C] 5.30 320.00
ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 34.40 9.50 23.50 Wetbulb [C] 4.00 300.00


Monthly Precipitation Summary

Monthly Total Precipitation from .epw [mm] Monthly Total Hours of Rain from .epw Monthly Total Precipitation in Site:Precipitation [mm] Monthly Total Roof Irrigation Depth [mm] Monthly Total Rain Collection Volume [m3]
Jan 0.00 0      
Feb 0.00 0      
Mar 0.00 0      
Apr 0.00 0      
May 0.00 0      
Jun 0.00 0      
Jul 0.00 0      
Aug 0.00 0      
Sep 90.00 25      
Oct 0.00 0      
Nov 0.00 0      
Dec 0.00 0      


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Net Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
BASEMENT_WALL_EAST BASEMENT_WALL_EAST_CFACTOR 1.00 0.845 0.940 118.87 118.87 90.00 90.00 E
BASEMENT_WALL_SOUTH BASEMENT_WALL_SOUTH_CFACTOR 1.00 0.845 0.940 139.09 139.09 180.00 90.00 S
BASEMENT_WALL_NORTH BASEMENT_WALL_NORTH_CFACTOR 1.00 0.845 0.940 139.09 139.09 0.00 90.00 N
PERIMETER_BOT_ZN_3_WALL_NORTH NONRES_EXT_WALL_GRD 0.30 1.223 1.498 200.61 105.88 0.00 90.00 N
PERIMETER_BOT_ZN_2_WALL_EAST NONRES_EXT_WALL_GRD 0.30 1.223 1.498 133.74 71.89 90.00 90.00 E
PERIMETER_BOT_ZN_1_WALL_SOUTH NONRES_EXT_WALL_GRD 0.30 1.223 1.498 200.61 105.88 180.00 90.00 S
PERIMETER_BOT_ZN_4_WALL_WEST NONRES_EXT_WALL_GRD 0.30 1.223 1.498 133.74 71.89 270.00 90.00 W
PERIMETER_MID_ZN_3_WALL_NORTH NONRES_EXT_WALL_MID 0.30 1.168 1.416 2006.06 1136.85 0.00 90.00 N
PERIMETER_MID_ZN_2_WALL_EAST NONRES_EXT_WALL_MID 0.30 1.168 1.416 1337.37 757.90 90.00 90.00 E
PERIMETER_MID_ZN_1_WALL_SOUTH NONRES_EXT_WALL_MID 0.30 1.168 1.416 2006.06 1136.85 180.00 90.00 S
PERIMETER_MID_ZN_4_WALL_WEST NONRES_EXT_WALL_MID 0.30 1.168 1.416 1337.37 757.90 270.00 90.00 W
PERIMETER_TOP_ZN_3_WALL_NORTH NONRES_EXT_WALL_TOP 0.30 1.459 1.867 200.61 113.68 0.00 90.00 N
PERIMETER_TOP_ZN_2_WALL_EAST NONRES_EXT_WALL_TOP 0.30 1.459 1.867 133.74 75.79 90.00 90.00 E
PERIMETER_TOP_ZN_1_WALL_SOUTH NONRES_EXT_WALL_TOP 0.30 1.459 1.867 200.61 113.68 180.00 90.00 S
PERIMETER_TOP_ZN_4_WALL_WEST NONRES_EXT_WALL_TOP 0.30 1.459 1.867 133.74 75.79 270.00 90.00 W
GROUNDFLOOR_PLENUM_WALL_NORTH NONRES_EXT_WALL_GRD 0.30 1.223 1.498 89.13 89.13 0.00 90.00 N
GROUNDFLOOR_PLENUM_WEST NONRES_EXT_WALL_GRD 0.30 1.223 1.498 59.42 59.42 270.00 90.00 W
GROUNDFLOOR_PLENUM_WALL_SOUTH NONRES_EXT_WALL_GRD 0.30 1.223 1.498 89.13 89.13 180.00 90.00 S
GROUNDFLOOR_PLENUM_WALL_EAST NONRES_EXT_WALL_GRD 0.30 1.223 1.498 59.42 59.42 90.00 90.00 E
MIDFLOOR_PLENUM_WALL_NORTH NONRES_EXT_WALL_MID 0.30 1.168 1.416 891.32 891.32 0.00 90.00 N
MIDFLOOR_PLENUM_WALL_WEST NONRES_EXT_WALL_MID 0.30 1.168 1.416 594.21 594.21 270.00 90.00 W
MIDFLOOR_PLENUM_WALL_SOUTH NONRES_EXT_WALL_MID 0.30 1.168 1.416 891.32 891.32 180.00 90.00 S
MIDFLOOR_PLENUM_WALL_EAST NONRES_EXT_WALL_MID 0.30 1.168 1.416 594.21 594.21 90.00 90.00 E
TOPFLOOR_PLENUM_WALL_NORTH NONRES_EXT_WALL_TOP 0.30 1.459 1.867 89.13 89.13 180.00 90.00 S
TOPFLOOR_PLENUM_WALL_EAST NONRES_EXT_WALL_TOP 0.30 1.459 1.867 59.42 59.42 90.00 90.00 E
TOPFLOOR_PLENUM_WALL_WEST NONRES_EXT_WALL_TOP 0.30 1.459 1.867 59.42 59.42 270.00 90.00 W
TOPFLOOR_PLENUM_WALL_SOUTH NONRES_EXT_WALL_TOP 0.30 1.459 1.867 89.13 89.13 0.00 90.00 N
BUILDING_ROOF NONRES_ROOF 0.55 0.221 0.228 3563.11 3563.11 180.00 0.00  
DATACENTER_BASEMENT_ZN_6_WALL_NORTH DATACENTER_BASEMENT_ZN_6_WALL_NORTH_CFACTOR 1.00 0.845 0.940 39.22 39.22 0.00 90.00 N
DATACENTER_BASEMENT_ZN_6_WALL_SOUTH DATACENTER_BASEMENT_ZN_6_WALL_SOUTH_CFACTOR 1.00 0.845 0.940 39.22 39.22 180.00 90.00 S
DATACENTER_BASEMENT_ZN_6_WALL_WEST DATACENTER_BASEMENT_ZN_6_WALL_WEST_CFACTOR 1.00 0.845 0.940 118.87 118.87 270.00 90.00 W


Opaque Interior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Net Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
BASEMENT_WALL_WEST INT_WALL 0.30 2.511 6.299 118.87 118.87 270.00 90.00 W
BASEMENT_FLOOR EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 2779.43 2779.43 0.00 180.00  
PERIMETER_BOT_ZN_2_FLOOR-PPAUTOCREATEOTHER INT_SLAB_CEILING 0.30 1.887 3.839 201.98 201.98 225.00 0.00  
PERIMETER_BOT_ZN_1_FLOOR-PPAUTOCREATEOTHER INT_SLAB_CEILING 0.30 1.887 3.839 250.34 250.34 180.00 0.00  
CORE_BOT_ZN_5_FLOOR-PPAUTOCREATEOTHER INT_SLAB_CEILING 0.30 1.887 3.839 2076.77 2076.77 180.00 0.00  
PERIMETER_BOT_ZN_3_FLOOR-PPAUTOCREATEOTHER INT_SLAB_CEILING 0.30 1.887 3.839 250.34 250.34 180.00 0.00  
CORE_BOT_ZN_5_WALL_SOUTH INT_WALL 0.30 2.511 6.299 173.00 173.00 180.00 90.00 S
CORE_BOT_ZN_5_WALL_WEST INT_WALL 0.30 2.511 6.299 108.64 108.64 270.00 90.00 W
CORE_BOT_ZN_5_WALL_NORTH INT_WALL 0.30 2.511 6.299 173.00 173.00 0.00 90.00 N
CORE_BOT_ZN_5_WALL_EAST INT_WALL 0.30 2.511 6.299 108.64 108.64 90.00 90.00 E
DATACENTER_BASEMENT_ZN_6_CEILING-CORE_BOT_ZN_5-PPAUTOCREATEOTHER INT_SLAB_FLOOR 0.30 1.887 3.839 419.30 419.30 0.00 180.00  
CORE_BOT_ZN_5_FLOOR INT_SLAB_FLOOR 0.30 1.887 3.839 2076.82 2076.82 0.00 180.00  
CORE_BOT_ZN_5_CEILING DROPCEILING 0.30 2.031 4.488 2496.12 2496.12 180.00 0.00  
CORE_MID_ZN_5_WALL_SOUTH INT_WALL 0.30 2.511 6.299 1729.99 1729.99 180.00 90.00 S
CORE_MID_ZN_5_WALL_WEST INT_WALL 0.30 2.511 6.299 1086.40 1086.40 270.00 90.00 W
CORE_MID_ZN_5_WALL_NORTH INT_WALL 0.30 2.511 6.299 1729.99 1729.99 0.00 90.00 N
CORE_MID_ZN_5_WALL_EAST INT_WALL 0.30 2.511 6.299 1086.40 1086.40 90.00 90.00 E
CORE_MID_ZN_5_FLOOR INT_SLAB_FLOOR 0.30 1.711 3.839 24961.20 24961.20 0.00 180.00  
CORE_MID_ZN_5_CEILING DROPCEILING 0.30 2.031 4.488 24961.20 24961.20 180.00 0.00  
CORE_TOP_ZN_5_WALL_SOUTH INT_WALL 0.30 2.511 6.299 173.00 173.00 180.00 90.00 S
CORE_TOP_ZN_5_WALL_WEST INT_WALL 0.30 2.511 6.299 108.64 108.64 270.00 90.00 W
CORE_TOP_ZN_5_WALL_NORTH INT_WALL 0.30 2.511 6.299 173.00 173.00 0.00 90.00 N
CORE_TOP_ZN_5_WALL_EAST INT_WALL 0.30 2.511 6.299 108.64 108.64 90.00 90.00 E
CORE_TOP_ZN_5_FLOOR INT_SLAB_FLOOR 0.30 1.711 3.839 2496.12 2496.12 0.00 180.00  
CORE_TOP_ZN_5_CEILING DROPCEILING 0.30 2.031 4.488 2496.12 2496.12 180.00 0.00  
PERIMETER_BOT_ZN_3_WALL_WEST INT_WALL 0.30 2.511 6.299 17.75 17.75 225.00 90.00 W
CORE_BOT_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 173.00 173.00 180.00 90.00 S
PERIMETER_BOT_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 17.75 17.75 135.00 90.00 S
DATACENTER_BOT_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 2.51 2.51 180.00 90.00 S
PERIMETER_BOT_ZN_3_FLOOR INT_SLAB_FLOOR 0.30 1.887 3.839 250.34 250.34 0.00 180.00  
DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_3-PPAUTOCREATEOTHER INT_SLAB_FLOOR 0.30 1.887 3.839 63.07 63.07 0.00 180.00  
PERIMETER_BOT_ZN_3_CEILING DROPCEILING 0.30 2.031 4.488 313.41 313.41 180.00 0.00  
PERIMETER_BOT_ZN_2_WALL_NORTH INT_WALL 0.30 2.511 6.299 17.75 17.75 315.00 90.00 N
CORE_BOT_ZN_5_WALL_EAST-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 108.64 108.64 270.00 90.00 W
PERIMETER_BOT_ZN_1_WALL_EAST-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 17.75 17.75 225.00 90.00 W
PERIMETER_BOT_ZN_2_FLOOR INT_SLAB_FLOOR 0.30 1.887 3.839 201.98 201.98 45.00 180.00  
PERIMETER_BOT_ZN_2_CEILING DROPCEILING 0.30 2.031 4.488 201.98 201.98 225.00 0.00  
PERIMETER_BOT_ZN_1_WALL_EAST INT_WALL 0.30 2.511 6.299 17.75 17.75 45.00 90.00 E
DATACENTER_BOT_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 2.51 2.51 0.00 90.00 N
PERIMETER_BOT_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 17.75 17.75 315.00 90.00 N
CORE_BOT_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 173.00 173.00 0.00 90.00 N
DATACENTER_BASEMENT_ZN_6-PERIMETER_BOT_ZN_1-PPAUTOCREATEOTHER INT_SLAB_FLOOR 0.30 1.887 3.839 63.07 63.07 0.00 180.00  
PERIMETER_BOT_ZN_1_FLOOR INT_SLAB_FLOOR 0.30 1.887 3.839 250.35 250.35 0.00 180.00  
PERIMETER_BOT_ZN_1_CEILING DROPCEILING 0.30 2.031 4.488 313.42 313.42 180.00 0.00  
PERIMETER_BOT_ZN_4_WALL_SOUTH INT_WALL 0.30 2.511 6.299 17.75 17.75 135.00 90.00 S
DATACENTER_BOT_ZN_6_WALL_WEST-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 108.64 108.64 90.00 90.00 E
PERIMETER_BOT_ZN_3_WALL_WEST-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 17.75 17.75 45.00 90.00 E
PERIMETER_BOT_ZN_4_FLOOR INT_SLAB_FLOOR 0.30 1.887 3.839 201.98 201.98 315.00 180.00  
PERIMETER_BOT_ZN_4_CEILING DROPCEILING 0.30 2.031 4.488 201.98 201.98 135.00 0.00  
PERIMETER_MID_ZN_3_WALL_WEST INT_WALL 0.30 2.511 6.299 177.47 177.47 225.00 90.00 W
CORE_MID_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 1729.99 1729.99 180.00 90.00 S
PERIMETER_MID_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 177.47 177.47 135.00 90.00 S
DATACENTER_MID_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 25.09 25.09 180.00 90.00 S
PERIMETER_MID_ZN_3_FLOOR INT_SLAB_FLOOR 0.30 1.711 3.839 3134.13 3134.13 0.00 180.00  
PERIMETER_MID_ZN_3_CEILING DROPCEILING 0.30 2.031 4.488 3134.13 3134.13 180.00 0.00  
PERIMETER_MID_ZN_2_WALL_NORTH INT_WALL 0.30 2.511 6.299 177.47 177.47 315.00 90.00 N
CORE_MID_ZN_5_WALL_EAST-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 1086.40 1086.40 270.00 90.00 W
PERIMETER_MID_ZN_1_WALL_EAST-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 177.47 177.47 225.00 90.00 W
PERIMETER_MID_ZN_2_FLOOR INT_SLAB_FLOOR 0.30 1.711 3.839 2019.75 2019.75 45.00 180.00  
PERIMETER_MID_ZN_2_CEILING DROPCEILING 0.30 2.031 4.488 2019.75 2019.75 225.00 0.00  
PERIMETER_MID_ZN_1_WALL_EAST INT_WALL 0.30 2.511 6.299 177.47 177.47 45.00 90.00 E
DATACENTER_MID_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 25.09 25.09 0.00 90.00 N
PERIMETER_MID_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 177.47 177.47 315.00 90.00 N
CORE_MID_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 1729.99 1729.99 0.00 90.00 N
PERIMETER_MID_ZN_1_FLOOR INT_SLAB_FLOOR 0.30 1.711 3.839 3134.20 3134.20 0.00 180.00  
PERIMETER_MID_ZN_1_CEILING DROPCEILING 0.30 2.031 4.488 3134.20 3134.20 180.00 0.00  
PERIMETER_MID_ZN_4_WALL_SOUTH INT_WALL 0.30 2.511 6.299 177.47 177.47 135.00 90.00 S
DATACENTER_MID_ZN_6_WALL_WEST-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 1086.40 1086.40 90.00 90.00 E
PERIMETER_MID_ZN_3_WALL_WEST-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 177.47 177.47 45.00 90.00 E
PERIMETER_MID_ZN_4_FLOOR INT_SLAB_FLOOR 0.30 1.711 3.839 2019.75 2019.75 315.00 180.00  
PERIMETER_MID_ZN_4_CEILING DROPCEILING 0.30 2.031 4.488 2019.75 2019.75 135.00 0.00  
PERIMETER_TOP_ZN_3_WALL_WEST INT_WALL 0.30 2.511 6.299 17.75 17.75 225.00 90.00 W
CORE_TOP_ZN_5_WALL_NORTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 173.00 173.00 180.00 90.00 S
PERIMETER_TOP_ZN_2_WALL_NORTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 17.75 17.75 135.00 90.00 S
DATACENTER_TOP_ZN_6_WALL_NORTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 2.51 2.51 180.00 90.00 S
PERIMETER_TOP_ZN_3_FLOOR INT_SLAB_FLOOR 0.30 1.711 3.839 313.41 313.41 0.00 180.00  
PERIMETER_TOP_ZN_3_CEILING DROPCEILING 0.30 2.031 4.488 313.41 313.41 180.00 0.00  
PERIMETER_TOP_ZN_2_WALL_NORTH INT_WALL 0.30 2.511 6.299 17.75 17.75 315.00 90.00 N
CORE_TOP_ZN_5_WALL_EAST-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 108.64 108.64 270.00 90.00 W
INT-PER3S-NE-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 17.75 17.75 225.00 90.00 W
PERIMETER_TOP_ZN_2_FLOOR INT_SLAB_FLOOR 0.30 1.711 3.839 201.98 201.98 45.00 180.00  
PERIMETER_TOP_ZN_2_CEILING DROPCEILING 0.30 2.031 4.488 201.98 201.98 225.00 0.00  
INT-PER3S-NE INT_WALL 0.30 2.511 6.299 17.75 17.75 45.00 90.00 E
DATACENTER_TOP_ZN_6_WALL_SOUTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 2.51 2.51 0.00 90.00 N
PERIMETER_TOP_ZN_4_WALL_SOUTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 17.75 17.75 315.00 90.00 N
CORE_TOP_ZN_5_WALL_SOUTH-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 173.00 173.00 0.00 90.00 N
PERIMETER_TOP_ZN_1_FLOOR INT_SLAB_FLOOR 0.30 1.711 3.839 313.42 313.42 0.00 180.00  
PERIMETER_TOP_ZN_1_CEILING DROPCEILING 0.30 2.031 4.488 313.42 313.42 180.00 0.00  
PERIMETER_TOP_ZN_4_WALL_SOUTH INT_WALL 0.30 2.511 6.299 17.75 17.75 135.00 90.00 S
DATACENTER_TOP_ZN_6_WALL_WEST-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 108.64 108.64 90.00 90.00 E
PERIMETER_TOP_ZN_3_WALL_WEST-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 17.75 17.75 45.00 90.00 E
PERIMETER_TOP_ZN_4_FLOOR INT_SLAB_FLOOR 0.30 1.711 3.839 201.98 201.98 315.00 180.00  
PERIMETER_TOP_ZN_4_CEILING DROPCEILING 0.30 2.031 4.488 201.98 201.98 135.00 0.00  
iz-CORE_BOT_ZN_5_CEILING DROPCEILING 0.30 2.031 4.488 2496.12 2496.12 0.00 180.00  
iz-PERIMETER_BOT_ZN_3_CEILING DROPCEILING 0.30 2.031 4.488 313.41 313.41 0.00 180.00  
iz-PERIMETER_BOT_ZN_2_CEILING DROPCEILING 0.30 2.031 4.488 201.98 201.98 45.00 180.00  
iz-PERIMETER_BOT_ZN_1_CEILING DROPCEILING 0.30 2.031 4.488 313.42 313.42 0.00 180.00  
iz-PERIMETER_BOT_ZN_4_CEILING DROPCEILING 0.30 2.031 4.488 201.98 201.98 315.00 180.00  
iz-DATACENTER_BOT_ZN_6_CEILING DROPCEILING 0.30 2.031 4.488 36.20 36.20 0.00 180.00  
GROUNDFLOOR_PLENUM_CEILING INT_SLAB_CEILING 0.30 2.104 3.839 3563.11 3563.11 180.00 0.00  
iz-CORE_MID_ZN_5_CEILING DROPCEILING 0.30 2.031 4.488 24961.20 24961.20 0.00 180.00  
iz-PERIMETER_MID_ZN_3_CEILING DROPCEILING 0.30 2.031 4.488 3134.13 3134.13 0.00 180.00  
iz-PERIMETER_MID_ZN_2_CEILING DROPCEILING 0.30 2.031 4.488 2019.75 2019.75 45.00 180.00  
iz-PERIMETER_MID_ZN_1_CEILING DROPCEILING 0.30 2.031 4.488 3134.20 3134.20 0.00 180.00  
iz-PERIMETER_MID_ZN_4_CEILING DROPCEILING 0.30 2.031 4.488 2019.75 2019.75 315.00 180.00  
iz-DATACENTER_MID_ZN_6_CEILING DROPCEILING 0.30 2.031 4.488 362.03 362.03 0.00 180.00  
MIDFLOOR_PLENUM_CEILING INT_SLAB_CEILING 0.30 2.104 3.839 35631.06 35631.06 180.00 0.00  
iz-CORE_TOP_ZN_5_CEILING DROPCEILING 0.30 2.031 4.488 2496.12 2496.12 0.00 180.00  
iz-PERIMETER_TOP_ZN_3_CEILING DROPCEILING 0.30 2.031 4.488 313.41 313.41 0.00 180.00  
iz-PERIMETER_TOP_ZN_2_CEILING DROPCEILING 0.30 2.031 4.488 201.98 201.98 45.00 180.00  
iz-PERIMETER_TOP_ZN_1_CEILING DROPCEILING 0.30 2.031 4.488 313.42 313.42 0.00 180.00  
iz-PERIMETER_TOP_ZN_4_CEILING DROPCEILING 0.30 2.031 4.488 201.98 201.98 315.00 180.00  
iz-DATACENTER_TOP_ZN_6_CEILING DROPCEILING 0.30 2.031 4.488 36.20 36.20 0.00 180.00  
DATACENTER_BOT_ZN_6_WALL_NORTH INT_WALL 0.30 2.511 6.299 2.51 2.51 0.00 90.00 N
DATACENTER_BOT_ZN_6_WALL_SOUTH INT_WALL 0.30 2.511 6.299 2.51 2.51 180.00 90.00 S
DATACENTER_BOT_ZN_6_WALL_EAST-PPAUTOCREATEOTHER INT_WALL 0.30 2.511 6.299 108.64 108.64 90.00 90.00 E
DATACENTER_BOT_ZN_6_WALL_WEST INT_WALL 0.30 2.511 6.299 108.64 108.64 270.00 90.00 W
DATACENTER_BOT_ZN_6_FLOOR INT_SLAB_FLOOR 0.30 1.887 3.839 36.20 36.20 0.00 180.00  
DATACENTER_BOT_ZN_6_CEILING DROPCEILING 0.30 2.031 4.488 36.20 36.20 180.00 0.00  
DATACENTER_MID_ZN_6_WALL_WEST INT_WALL 0.30 2.511 6.299 1086.40 1086.40 270.00 90.00 W
DATACENTER_MID_ZN_6_WALL_SOUTH INT_WALL 0.30 2.511 6.299 25.09 25.09 180.00 90.00 S
DATACENTER_MID_ZN_6_WALL_EAST INT_WALL 0.30 2.511 6.299 1086.40 1086.40 90.00 90.00 E
DATACENTER_MID_ZN_6_WALL_NORTH INT_WALL 0.30 2.511 6.299 25.09 25.09 0.00 90.00 N
DATACENTER_MID_ZN_6_FLOOR INT_SLAB_FLOOR 0.30 1.711 3.839 362.03 362.03 0.00 180.00  
DATACENTER_MID_ZN_6_CEILING DROPCEILING 0.30 2.031 4.488 362.03 362.03 180.00 0.00  
DATACENTER_TOP_ZN_6_WALL_EAST INT_WALL 0.30 2.511 6.299 108.64 108.64 90.00 90.00 E
DATACENTER_TOP_ZN_6_WALL_WEST INT_WALL 0.30 2.511 6.299 108.64 108.64 270.00 90.00 W
DATACENTER_TOP_ZN_6_WALL_SOUTH INT_WALL 0.30 2.511 6.299 2.51 2.51 180.00 90.00 S
DATACENTER_TOP_ZN_6_WALL_NORTH INT_WALL 0.30 2.511 6.299 2.51 2.51 0.00 90.00 N
DATACENTER_TOP_ZN_6_FLOOR INT_SLAB_FLOOR 0.30 1.711 3.839 36.20 36.20 0.00 180.00  
DATACENTER_TOP_ZN_6_CEILING DROPCEILING 0.30 2.031 4.488 36.20 36.20 180.00 0.00  
DATACENTER_BASEMENT_ZN_6_WALL_EAST INT_WALL 0.30 2.511 6.299 118.87 118.87 90.00 90.00 E
DATACENTER_BASEMENT_ZN_6_FLOOR EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 783.68 783.68 0.00 180.00  
DATACENTER_BOT_ZN_6_FLOOR-PPAUTOCREATEOTHER INT_SLAB_CEILING 0.30 1.887 3.839 36.20 36.20 180.00 0.00  
DATACENTER_BASEMENT_ZN_6_CEILING-CORE_BOT_ZN_5 INT_SLAB_CEILING 0.30 1.887 3.839 419.35 419.35 180.00 0.00  
PERIMETER_BOT_ZN_4_FLOOR-PPAUTOCREATEOTHER INT_SLAB_CEILING 0.30 1.887 3.839 201.98 201.98 135.00 0.00  
DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_1 INT_SLAB_CEILING 0.30 1.887 3.839 63.08 63.08 180.00 0.00  
DATACENTER_BASEMENT_ZN_6_CEILING-PERIMETER_BOT_ZN_3 INT_SLAB_CEILING 0.30 1.887 3.839 63.07 63.07 180.00 0.00  
BASEMENT_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 7126.21   0.00 90.00 N
CORE_BOTTOM_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 5064.65   0.00 90.00 N
CORE_MID_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 50646.53   0.00 90.00 N
CORE_TOP_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 5064.65   0.00 90.00 N
PERIMETER_BOT_ZN_3_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 626.83   0.00 90.00 N
PERIMETER_BOT_ZN_2_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 403.95   0.00 90.00 N
PERIMETER_BOT_ZN_1_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 626.84   0.00 90.00 N
PERIMETER_BOT_ZN_4_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 403.95   0.00 90.00 N
PERIMETER_MID_ZN_3_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 6268.26   0.00 90.00 N
PERIMETER_MID_ZN_2_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 4039.50   0.00 90.00 N
PERIMETER_MID_ZN_1_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 6268.35   0.00 90.00 N
PERIMETER_MID_ZN_4_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 4039.48   0.00 90.00 N
PERIMETER_TOP_ZN_3_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 626.83   0.00 90.00 N
PERIMETER_TOP_ZN_2_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 403.95   0.00 90.00 N
PERIMETER_TOP_ZN_1_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 626.84   0.00 90.00 N
PERIMETER_TOP_ZN_4_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 403.95   0.00 90.00 N


Exterior Fenestration

Construction Frame and Divider Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] NFRC Product Type Assembly U-Factor [W/m2-K] Assembly SHGC Assembly Visible Transmittance Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 WINDOW_U_0.4237_SHGC_NORTH_0.25   17.38 0.00 0.00 17.38 17.38 2.408 0.251 0.251             No PERIMETER_BOT_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 WINDOW_U_0.4237_SHGC_NORTH_0.25   17.38 0.00 0.00 17.38 17.38 2.408 0.251 0.251             No PERIMETER_BOT_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 WINDOW_U_0.4237_SHGC_NORTH_0.25   17.38 0.00 0.00 17.38 17.38 2.408 0.251 0.251             No PERIMETER_BOT_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 WINDOW_U_0.4237_SHGC_NORTH_0.25   17.38 0.00 0.00 17.38 17.38 2.408 0.251 0.251             No PERIMETER_BOT_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 WINDOW_U_0.4237_SHGC_NORTH_0.25   17.38 0.00 0.00 17.38 17.38 2.408 0.251 0.251             No PERIMETER_BOT_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 WINDOW_U_0.4237_SHGC_EAST_0.25   19.32 0.00 0.00 19.32 19.32 2.408 0.251 0.251             No PERIMETER_BOT_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 WINDOW_U_0.4237_SHGC_EAST_0.25   19.32 0.00 0.00 19.32 19.32 2.408 0.251 0.251             No PERIMETER_BOT_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 WINDOW_U_0.4237_SHGC_EAST_0.25   19.32 0.00 0.00 19.32 19.32 2.408 0.251 0.251             No PERIMETER_BOT_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 WINDOW_U_0.4237_SHGC_SOUTH_0.25   17.38 0.00 0.00 17.38 17.38 2.408 0.251 0.251             No PERIMETER_BOT_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 WINDOW_U_0.4237_SHGC_SOUTH_0.25   17.38 0.00 0.00 17.38 17.38 2.408 0.251 0.251             No PERIMETER_BOT_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 WINDOW_U_0.4237_SHGC_SOUTH_0.25   17.38 0.00 0.00 17.38 17.38 2.408 0.251 0.251             No PERIMETER_BOT_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 WINDOW_U_0.4237_SHGC_SOUTH_0.25   17.38 0.00 0.00 17.38 17.38 2.408 0.251 0.251             No PERIMETER_BOT_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 WINDOW_U_0.4237_SHGC_SOUTH_0.25   17.38 0.00 0.00 17.38 17.38 2.408 0.251 0.251             No PERIMETER_BOT_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 WINDOW_U_0.4237_SHGC_WEST_0.25   19.32 0.00 0.00 19.32 19.32 2.408 0.251 0.251             No PERIMETER_BOT_ZN_4_WALL_WEST 270.00 90.00 W
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 WINDOW_U_0.4237_SHGC_WEST_0.25   19.32 0.00 0.00 19.32 19.32 2.408 0.251 0.251             No PERIMETER_BOT_ZN_4_WALL_WEST 270.00 90.00 W
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 WINDOW_U_0.4237_SHGC_WEST_0.25   19.32 0.00 0.00 19.32 19.32 2.408 0.251 0.251             No PERIMETER_BOT_ZN_4_WALL_WEST 270.00 90.00 W
PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW WINDOW_U_0.4237_SHGC_NORTH_0.25   86.92 0.00 0.00 86.92 869.21 2.408 0.251 0.251             No PERIMETER_MID_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_MID_ZN_2_WALL_EAST_WINDOW WINDOW_U_0.4237_SHGC_EAST_0.25   57.95 0.00 0.00 57.95 579.48 2.408 0.251 0.251             No PERIMETER_MID_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW WINDOW_U_0.4237_SHGC_SOUTH_0.25   86.92 0.00 0.00 86.92 869.21 2.408 0.251 0.251             No PERIMETER_MID_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_MID_ZN_4_WALL_WEST_WINDOW WINDOW_U_0.4237_SHGC_WEST_0.25   57.95 0.00 0.00 57.95 579.48 2.408 0.251 0.251             No PERIMETER_MID_ZN_4_WALL_WEST 270.00 90.00 W
PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW WINDOW_U_0.4237_SHGC_NORTH_0.25   86.92 0.00 0.00 86.92 86.92 2.408 0.251 0.251             No PERIMETER_TOP_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW WINDOW_U_0.4237_SHGC_EAST_0.25   57.95 0.00 0.00 57.95 57.95 2.408 0.251 0.251             No PERIMETER_TOP_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW WINDOW_U_0.4237_SHGC_SOUTH_0.25   86.92 0.00 0.00 86.92 86.92 2.408 0.251 0.251             No PERIMETER_TOP_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW WINDOW_U_0.4237_SHGC_WEST_0.25   57.95 0.00 0.00 57.95 57.95 2.408 0.251 0.251             No PERIMETER_TOP_ZN_4_WALL_WEST 270.00 90.00 W
Total or Average             3476.85 2.408 0.251 0.251                      
North Total or Average             1043.06 2.408 0.251 0.251                      
Non-North Total or Average             2433.80 2.408 0.251 0.251                      


Exterior Fenestration Shaded State

Frame and Divider Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance NFRC Product Type Assembly U-Factor [W/m2-K] Assembly SHGC Assembly Visible Transmittance
None                


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance
Total or Average     0.00 - - -


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_BOT_ZN_3_WALL_NORTH
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_BOT_ZN_3_WALL_NORTH
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR3 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_BOT_ZN_3_WALL_NORTH
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR4 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_BOT_ZN_3_WALL_NORTH
PERIMETER_BOT_ZN_2_WALL_EAST_DOOR1 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_BOT_ZN_2_WALL_EAST
PERIMETER_BOT_ZN_2_WALL_EAST_DOOR2 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_BOT_ZN_2_WALL_EAST
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_BOT_ZN_1_WALL_SOUTH
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_BOT_ZN_1_WALL_SOUTH
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR3 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_BOT_ZN_1_WALL_SOUTH
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR4 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_BOT_ZN_1_WALL_SOUTH
PERIMETER_BOT_ZN_4_WALL_WEST_DOOR1 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_BOT_ZN_4_WALL_WEST
PERIMETER_BOT_ZN_4_WALL_WEST_DOOR2 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_BOT_ZN_4_WALL_WEST


Interior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_MID_ZN_2_WALL_EAST_WINDOW 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
PERIMETER_MID_ZN_4_WALL_WEST_WINDOW 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Interior Lighting

Zone Name Space Name Space Type Lighting Power Density [W/m2] Space Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
BASEMENT_LIGHTS BASEMENT BASEMENT GENERAL 5.8895 2779.43 16369.36 LightsWired LTG_SCH_OFFICE 45.29 168.00 44.12 0.0000 Y 135.58
CORE_BOTTOM_LIGHTS CORE_BOTTOM CORE_BOTTOM GENERAL 5.8895 2496.12 14700.84 LightsWired LTG_SCH_OFFICE 45.29 168.00 44.12 0.0000 Y 121.76
CORE_MID_LIGHTS CORE_MID CORE_MID GENERAL 5.8895 24961.20 147008.37 LightsWired LTG_SCH_OFFICE 45.29 168.00 44.12 0.0000 Y 1217.57
CORE_TOP_LIGHTS CORE_TOP CORE_TOP GENERAL 5.8895 2496.12 14700.84 LightsWired LTG_SCH_OFFICE 45.29 168.00 44.12 0.0000 Y 121.76
PERIMETER_BOT_ZN_3_LIGHTS PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3 GENERAL 5.8895 313.41 1845.84 LightsWired LTG_SCH_OFFICE 45.29 168.00 26.40 0.0000 Y 9.15
PERIMETER_BOT_ZN_2_LIGHTS PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2 GENERAL 5.8895 201.98 1189.53 LightsWired LTG_SCH_OFFICE 45.29 168.00 25.86 0.0000 Y 5.77
PERIMETER_BOT_ZN_1_LIGHTS PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1 GENERAL 5.8895 313.42 1845.88 LightsWired LTG_SCH_OFFICE 45.29 168.00 25.54 0.0000 Y 8.85
PERIMETER_BOT_ZN_4_LIGHTS PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4 GENERAL 5.8895 201.98 1189.53 LightsWired LTG_SCH_OFFICE 45.29 168.00 26.13 0.0000 Y 5.83
PERIMETER_MID_ZN_3_LIGHTS PERIMETER_MID_ZN_3 PERIMETER_MID_ZN_3 GENERAL 5.8895 3134.13 18458.37 LightsWired LTG_SCH_OFFICE 45.29 168.00 26.40 0.0000 Y 91.47
PERIMETER_MID_ZN_2_LIGHTS PERIMETER_MID_ZN_2 PERIMETER_MID_ZN_2 GENERAL 5.8895 2019.75 11895.27 LightsWired LTG_SCH_OFFICE 45.29 168.00 25.85 0.0000 Y 57.72
PERIMETER_MID_ZN_1_LIGHTS PERIMETER_MID_ZN_1 PERIMETER_MID_ZN_1 GENERAL 5.8895 3134.20 18458.77 LightsWired LTG_SCH_OFFICE 45.29 168.00 25.56 0.0000 Y 88.55
PERIMETER_MID_ZN_4_LIGHTS PERIMETER_MID_ZN_4 PERIMETER_MID_ZN_4 GENERAL 5.8895 2019.75 11895.27 LightsWired LTG_SCH_OFFICE 45.29 168.00 26.11 0.0000 Y 58.30
PERIMETER_TOP_ZN_3_LIGHTS PERIMETER_TOP_ZN_3 PERIMETER_TOP_ZN_3 GENERAL 5.8895 313.41 1845.84 LightsWired LTG_SCH_OFFICE 45.29 168.00 26.40 0.0000 Y 9.15
PERIMETER_TOP_ZN_2_LIGHTS PERIMETER_TOP_ZN_2 PERIMETER_TOP_ZN_2 GENERAL 5.8895 201.98 1189.53 LightsWired LTG_SCH_OFFICE 45.29 168.00 25.85 0.0000 Y 5.77
PERIMETER_TOP_ZN_1_LIGHTS PERIMETER_TOP_ZN_1 PERIMETER_TOP_ZN_1 GENERAL 5.8895 313.42 1845.88 LightsWired LTG_SCH_OFFICE 45.29 168.00 25.56 0.0000 Y 8.86
PERIMETER_TOP_ZN_4_LIGHTS PERIMETER_TOP_ZN_4 PERIMETER_TOP_ZN_4 GENERAL 5.8895 201.98 1189.53 LightsWired LTG_SCH_OFFICE 45.29 168.00 26.11 0.0000 Y 5.83
DATACENTER_BASEMENT_LIGHTS DATACENTER_BASEMENT_ZN_6 DATACENTER_BASEMENT_ZN_6 GENERAL 5.8895 783.68 4615.46 LightsWired LTG_SCH_OFFICE 45.29 168.00 44.12 0.0000 Y 38.23
DATACENTER_BOT_LIGHTS DATACENTER_BOT_ZN_6 DATACENTER_BOT_ZN_6 GENERAL 8.8011 36.20 318.62 LightsWired LTG_SCH_DATACENTER 56.02 168.00 54.57 0.0000 Y 3.26
DATACENTER_MID_LIGHTS DATACENTER_MID_ZN_6 DATACENTER_MID_ZN_6 GENERAL 8.8011 362.03 3186.24 LightsWired LTG_SCH_DATACENTER 56.02 168.00 54.57 0.0000 Y 32.64
DATACENTER_TOP_LIGHTS DATACENTER_TOP_ZN_6 DATACENTER_TOP_ZN_6 GENERAL 8.8011 36.20 318.62 LightsWired LTG_SCH_DATACENTER 56.02 168.00 54.57 0.0000 Y 3.26
Interior Lighting Total       5.9168 46320.38 274067.57               637.68


Daylighting

Zone Control Name Daylighting Method Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
PERIMETER_BOT_ZN_1_DAYLREFPT1 PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_DAYLCTRL SplitFlux Continuous/Off 0.39 1845.88 711.95
PERIMETER_BOT_ZN_1_DAYLREFPT2 PERIMETER_BOT_ZN_1 PERIMETER_BOT_ZN_1_DAYLCTRL SplitFlux Continuous/Off 0.14 1845.88 255.65
PERIMETER_BOT_ZN_2_DAYLREFPT1 PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_DAYLCTRL SplitFlux Continuous/Off 0.39 1189.53 458.80
PERIMETER_BOT_ZN_2_DAYLREFPT2 PERIMETER_BOT_ZN_2 PERIMETER_BOT_ZN_2_DAYLCTRL SplitFlux Continuous/Off 0.14 1189.53 164.75
PERIMETER_BOT_ZN_3_DAYLREFPT1 PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_DAYLCTRL SplitFlux Continuous/Off 0.39 1845.84 711.94
PERIMETER_BOT_ZN_3_DAYLREFPT2 PERIMETER_BOT_ZN_3 PERIMETER_BOT_ZN_3_DAYLCTRL SplitFlux Continuous/Off 0.14 1845.84 255.65
PERIMETER_BOT_ZN_4_DAYLREFPT1 PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_DAYLCTRL SplitFlux Continuous/Off 0.39 1189.53 458.80
PERIMETER_BOT_ZN_4_DAYLREFPT2 PERIMETER_BOT_ZN_4 PERIMETER_BOT_ZN_4_DAYLCTRL SplitFlux Continuous/Off 0.14 1189.53 164.75
PERIMETER_MID_ZN_1_DAYLREFPT1 PERIMETER_MID_ZN_1 PERIMETER_MID_ZN_1_DAYLCTRL SplitFlux Continuous/Off 0.39 1845.88 711.95
PERIMETER_MID_ZN_1_DAYLREFPT2 PERIMETER_MID_ZN_1 PERIMETER_MID_ZN_1_DAYLCTRL SplitFlux Continuous/Off 0.14 1845.88 255.65
PERIMETER_MID_ZN_2_DAYLREFPT1 PERIMETER_MID_ZN_2 PERIMETER_MID_ZN_2_DAYLCTRL SplitFlux Continuous/Off 0.39 1189.53 458.80
PERIMETER_MID_ZN_2_DAYLREFPT2 PERIMETER_MID_ZN_2 PERIMETER_MID_ZN_2_DAYLCTRL SplitFlux Continuous/Off 0.14 1189.53 164.75
PERIMETER_MID_ZN_3_DAYLREFPT1 PERIMETER_MID_ZN_3 PERIMETER_MID_ZN_3_DAYLCTRL SplitFlux Continuous/Off 0.39 1845.84 711.94
PERIMETER_MID_ZN_3_DAYLREFPT2 PERIMETER_MID_ZN_3 PERIMETER_MID_ZN_3_DAYLCTRL SplitFlux Continuous/Off 0.14 1845.84 255.65
PERIMETER_MID_ZN_4_DAYLREFPT1 PERIMETER_MID_ZN_4 PERIMETER_MID_ZN_4_DAYLCTRL SplitFlux Continuous/Off 0.39 1189.53 458.80
PERIMETER_MID_ZN_4_DAYLREFPT2 PERIMETER_MID_ZN_4 PERIMETER_MID_ZN_4_DAYLCTRL SplitFlux Continuous/Off 0.14 1189.53 164.75
PERIMETER_TOP_ZN_1_DAYLREFPT1 PERIMETER_TOP_ZN_1 PERIMETER_TOP_ZN_1_DAYLCTRL SplitFlux Continuous/Off 0.39 1845.88 711.95
PERIMETER_TOP_ZN_1_DAYLREFPT2 PERIMETER_TOP_ZN_1 PERIMETER_TOP_ZN_1_DAYLCTRL SplitFlux Continuous/Off 0.14 1845.88 255.65
PERIMETER_TOP_ZN_2_DAYLREFPT1 PERIMETER_TOP_ZN_2 PERIMETER_TOP_ZN_2_DAYLCTRL SplitFlux Continuous/Off 0.39 1189.53 458.80
PERIMETER_TOP_ZN_2_DAYLREFPT2 PERIMETER_TOP_ZN_2 PERIMETER_TOP_ZN_2_DAYLCTRL SplitFlux Continuous/Off 0.14 1189.53 164.75
PERIMETER_TOP_ZN_3_DAYLREFPT1 PERIMETER_TOP_ZN_3 PERIMETER_TOP_ZN_3_DAYLCTRL SplitFlux Continuous/Off 0.39 1845.84 711.94
PERIMETER_TOP_ZN_3_DAYLREFPT2 PERIMETER_TOP_ZN_3 PERIMETER_TOP_ZN_3_DAYLCTRL SplitFlux Continuous/Off 0.14 1845.84 255.65
PERIMETER_TOP_ZN_4_DAYLREFPT1 PERIMETER_TOP_ZN_4 PERIMETER_TOP_ZN_4_DAYLCTRL SplitFlux Continuous/Off 0.39 1189.53 458.80
PERIMETER_TOP_ZN_4_DAYLREFPT2 PERIMETER_TOP_ZN_4 PERIMETER_TOP_ZN_4_DAYLCTRL SplitFlux Continuous/Off 0.14 1189.53 164.75


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
EXTERIOR_LIGHTS_A 9973.05 AstronomicalClock -   41.77 41.77 78.20
EXTERIOR_LIGHTS_B 991.40 AstronomicalClock -   83.77 62.77 11.68
EXTERIOR_LIGHTS_C 26646.63 AstronomicalClock -   83.77 47.60 238.09
Exterior Lighting Total 37611.08           327.97



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Central Plant

Type Reference Capacity [W] Reference Efficiency [W/W] Rated Capacity [W] Rated Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
BYPASS HEAT EXCHANGER HeatExchanger:FluidToFluid 2712066.38          
HEATSYS1 BOILER Boiler:HotWater 2171374.48 0.81        
COOLSYS1 CHILLER1 Chiller:Electric:ReformulatedEIR 1374850.56 6.28 1315909.90 5.98 6.84 23.33
COOLSYS1 CHILLER2 Chiller:Electric:ReformulatedEIR 1374850.56 6.28 1315909.90 5.98 6.84 23.33
CENTRAL TOWER FluidCooler:TwoSpeed 148548.00          
CENTRAL BOILER Boiler:HotWater 108361.02 0.80        
TOWERWATERSYS COOLTOWER 1 CoolingTower:VariableSpeed 1631210.05          
TOWERWATERSYS COOLTOWER 2 CoolingTower:VariableSpeed 1631210.05          


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
VAV_BOT WITH REHEAT COOLING COIL Coil:Cooling:Water 222106.69 234749.86 155263.27 79486.59 0.66 - 25110.49 254.68
VAV_MID WITH REHEAT COOLING COIL Coil:Cooling:Water 2160566.93 2212547.11 1455239.90 757307.21 0.66 - 237192.67 2405.74
VAV_TOP WITH REHEAT COOLING COIL Coil:Cooling:Water 217377.98 231878.11 153620.05 78258.06 0.66 - 24794.24 251.48
CAV_BAS COOLING COIL Coil:Cooling:Water 118266.12 129098.21 86396.10 42702.11 0.67 - 13461.75 136.54
AIRLOOP DATACENTER BOT COOLING COIL Coil:Cooling:WaterToAirHeatPump:EquationFit   9347.24 6482.34 2864.90 0.69 0.00    
AIRLOOP DATACENTER MID COOLING COIL Coil:Cooling:WaterToAirHeatPump:EquationFit   89037.51 61684.77 27352.74 0.69 0.00    
AIRLOOP DATACENTER TOP COOLING COIL Coil:Cooling:WaterToAirHeatPump:EquationFit   9033.64 6260.53 2773.11 0.69 0.00    
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.

DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER User [Btu/W-h] SEER Standard [Btu/W-h] IEER [Btu/W-h]
None              


DX Cooling Coil ASHRAE 127 Standard Ratings Report

DX Cooling Coil Type Rated Net Cooling Capacity Test A [W] Rated Electric Power Test A [W] Rated Net Cooling Capacity Test B [W] Rated Electric Power Test B [W] Rated Net Cooling Capacity Test C [W] Rated Electric Power Test C [W] Rated Net Cooling Capacity Test D [W] Rated Electric Power Test D [W]
None                  


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
CORE_BOTTOM VAV BOX REHEAT COIL Coil:Heating:Water 18165.30 17224.72 -
CORE_MID VAV BOX REHEAT COIL Coil:Heating:Water 418017.04 396068.07 -
CORE_TOP VAV BOX REHEAT COIL Coil:Heating:Water 83477.02 79110.21 -
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL Coil:Heating:Water 11065.20 10485.93 -
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL Coil:Heating:Water 7705.64 7302.06 -
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL Coil:Heating:Water 13018.23 12336.14 -
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL Coil:Heating:Water 6029.76 5712.20 -
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL Coil:Heating:Water 196410.77 186102.81 -
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL Coil:Heating:Water 128817.45 122056.48 -
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL Coil:Heating:Water 194062.32 183878.03 -
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL Coil:Heating:Water 122814.77 116369.80 -
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL Coil:Heating:Water 25960.82 24597.22 -
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL Coil:Heating:Water 16936.53 16046.90 -
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL Coil:Heating:Water 25682.01 24333.10 -
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL Coil:Heating:Water 16549.16 15679.92 -
VAV_BOT WITH REHEAT HEATING COIL Coil:Heating:Water 56676.84 42306.86 -
VAV_MID WITH REHEAT HEATING COIL Coil:Heating:Water 534071.93 397145.33 -
VAV_TOP WITH REHEAT HEATING COIL Coil:Heating:Water 56240.19 41987.38 -
CAV_BAS HEATING COIL Coil:Heating:Water 239673.49 188700.33 -
AIRLOOP DATACENTER BOT HEATING COIL Coil:Heating:WaterToAirHeatPump:EquationFit   9347.24 0.00
AIRLOOP DATACENTER MID HEATING COIL Coil:Heating:WaterToAirHeatPump:EquationFit   89037.51 0.00
AIRLOOP DATACENTER TOP HEATING COIL Coil:Heating:WaterToAirHeatPump:EquationFit   9033.64 0.00
AIRLOOP DATACENTER BOT_SUPPHEATCOIL Coil:Heating:Electric   844.40 1.00
AIRLOOP DATACENTER MID_SUPPHEATCOIL Coil:Heating:Electric   8443.96 1.00
AIRLOOP DATACENTER TOP_SUPPHEATCOIL Coil:Heating:Electric   844.40 1.00
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.

Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electricity Rate [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction Fan Energy Index End Use Subcategory Design Day Name for Fan Sizing Peak Date/Time for Fan Sizing Peak
VAV_BOT WITH REHEAT FAN Fan:VariableVolume 0.61 1389.42 8.63 19711.17 2283.73 1.00 1.12 General ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00
VAV_MID WITH REHEAT FAN Fan:VariableVolume 0.61 1389.42 79.89 182457.23 2283.73 1.00 1.07 General ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00
VAV_TOP WITH REHEAT FAN Fan:VariableVolume 0.61 1389.42 8.57 19573.85 2283.73 1.00 1.12 General ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 16:00:00
CAV_BAS FAN Fan:ConstantVolume 0.60 1018.41 4.95 8388.48 1695.65 1.00 1.16 General ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00
AIRLOOP DATACENTER BOT SUPPLY FAN Fan:OnOff 0.56 622.50 0.47 530.69 1120.11 1.00 1.63 General ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00
AIRLOOP DATACENTER MID SUPPLY FAN Fan:OnOff 0.56 622.50 4.50 5045.68 1120.11 1.00 1.16 General ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00
AIRLOOP DATACENTER TOP SUPPLY FAN Fan:OnOff 0.56 622.50 0.46 512.23 1120.11 1.00 1.65 General ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00


Pumps

Type Control Head [pa] Water Flow [m3/s] Electricity Rate [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W] End Use Subcategory
COOLSYS1 PUMP SECONDARY Pump:VariableSpeed Intermittent 133527.72 0.115644 23593.90 204022.71 0.91 General
HEATSYS1 PUMP Pump:VariableSpeed Intermittent 180705.70 0.018996 5664.16 298174.34 0.91 General
COOLSYS1 PUMP Pump:ConstantSpeed Intermittent 92445.74 0.115644 16334.86 141251.81 0.91 General
PLANT CIRC PUMP Pump:ConstantSpeed Intermittent 179045.11 0.002631 664.31 252524.76 0.91 General
SWHSYS1 PUMP Pump:ConstantSpeed Intermittent 3168.45 0.000440 5.96 13540.37 0.30 General
TOWERWATERSYS PUMP HeaderedPumps:VariableSpeed Intermittent 180718.98 0.136073 40576.32 298196.27 0.91 General


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SWHSYS1 WATER HEATER WaterHeater:Mixed 1.14 87921.32 0.80 0.50 0.08



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Zone Sensible Cooling

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
BASEMENT 66277.48 66277.48 23.85 4.947 4.947 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 24.00 24.00 0.00903 27.37 0.01446 1.200 0.00
CORE_BOTTOM 72448.24 72448.24 29.02 5.408 5.408 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 24.00 24.00 0.00893 27.37 0.01446 1.078 0.00
CORE_MID 680540.16 680540.16 272.64 50.787 50.787 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 24.00 24.00 0.00896 27.37 0.01446 10.778 0.00
CORE_TOP 67530.42 67530.42 27.05 5.040 5.040 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 24.00 24.00 0.00896 27.37 0.01446 1.078 0.00
PERIMETER_BOT_ZN_3 11685.63 11685.63 37.29 0.873 0.873 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 24.00 24.00 0.00887 27.37 0.01446 0.135 0.00
PERIMETER_BOT_ZN_2 11657.88 11657.88 57.72 0.879 0.879 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 09:50:00 24.00 24.00 0.00874 30.52 0.01447 0.087 0.00
PERIMETER_BOT_ZN_1 13517.12 13517.12 43.13 1.019 1.019 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:50:00 24.00 24.00 0.00881 34.32 0.01447 0.135 0.00
PERIMETER_BOT_ZN_4 15230.41 15230.41 75.41 1.148 1.148 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:10:00 24.00 24.00 0.00868 32.91 0.01447 0.087 0.00
PERIMETER_MID_ZN_3 109114.90 109114.90 348.15 8.151 8.151 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 24.00 24.00 0.00895 27.37 0.01446 1.353 0.00
PERIMETER_MID_ZN_2 119922.26 119922.26 593.75 9.037 9.037 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:00:00 24.00 24.00 0.00876 30.79 0.01447 0.872 0.00
PERIMETER_MID_ZN_1 125553.30 125553.30 400.59 9.462 9.462 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 24.00 24.00 0.00888 34.40 0.01447 1.353 0.00
PERIMETER_MID_ZN_4 126285.02 126285.02 625.25 9.517 9.517 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:20:00 24.00 24.00 0.00875 32.75 0.01447 0.872 0.00
PERIMETER_TOP_ZN_3 12383.30 12383.30 39.51 0.933 0.933 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:30:00 24.00 24.00 0.00890 34.12 0.01447 0.135 0.00
PERIMETER_TOP_ZN_2 12299.72 12299.72 60.90 0.927 0.927 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:20:00 24.00 24.00 0.00877 31.26 0.01447 0.087 0.00
PERIMETER_TOP_ZN_1 14147.27 14147.27 45.14 1.066 1.066 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:20:00 24.00 24.00 0.00886 34.40 0.01447 0.135 0.00
PERIMETER_TOP_ZN_4 13790.79 13790.79 68.28 1.039 1.039 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:20:00 24.00 24.00 0.00874 32.75 0.01447 0.087 0.00
DATACENTER_BOT_ZN_6 7971.91 7971.91 220.20 0.474 0.474 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:20:00 27.00 27.00 0.00850 24.96 0.01446 0.016 0.00
DATACENTER_MID_ZN_6 75795.72 75795.72 2093.65 4.505 4.505 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:20:00 27.00 27.00 0.00850 24.96 0.01446 0.156 0.00
DATACENTER_TOP_ZN_6 7693.76 7693.76 212.52 0.457 0.457 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 27.00 27.00 0.00859 30.70 0.01447 0.016 0.00
DATACENTER_BASEMENT_ZN_6 369399.38 369399.38 471.37 21.956 21.956 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 07:00:00 27.00 27.00 0.00854 25.75 0.01446 0.338 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

Zone Sensible Heating

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
BASEMENT 0.00 0.00 0.00 0.000 1.200 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:30:00 21.00 23.75 0.00230 -6.30 0.00230 1.200 0.00
CORE_BOTTOM 0.00 0.00 0.00 0.000 1.078 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 06:20:00 19.60 21.40 0.00230 -6.30 0.00230 1.078 0.00
CORE_MID 241022.25 241022.25 96.56 10.532 10.778 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 21.00 21.00 0.00800 -6.30 0.00230 10.778 0.00
CORE_TOP 58466.64 58466.64 23.42 2.576 2.576 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 21.00 21.00 0.00800 -6.30 0.00230 1.078 0.00
PERIMETER_BOT_ZN_3 7750.80 7750.80 24.73 0.342 0.342 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 21.00 21.00 0.00766 -6.30 0.00230 0.135 0.00
PERIMETER_BOT_ZN_2 5396.64 5396.64 26.72 0.238 0.238 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 21.00 21.00 0.00771 -6.30 0.00230 0.087 0.00
PERIMETER_BOT_ZN_1 9115.86 9115.86 29.09 0.402 0.402 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 21.00 21.00 0.00777 -6.30 0.00230 0.135 0.00
PERIMETER_BOT_ZN_4 3804.07 3804.07 18.83 0.167 0.167 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 21.00 21.00 0.00742 -6.30 0.00230 0.087 0.00
PERIMETER_MID_ZN_3 137469.40 137469.40 438.62 6.075 6.075 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 21.00 21.00 0.00779 -6.30 0.00230 1.353 0.00
PERIMETER_MID_ZN_2 90158.89 90158.89 446.39 3.984 3.984 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 21.00 21.00 0.00779 -6.30 0.00230 0.872 0.00
PERIMETER_MID_ZN_1 135827.79 135827.79 433.37 6.002 6.002 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 21.00 21.00 0.00779 -6.30 0.00230 1.353 0.00
PERIMETER_MID_ZN_4 85962.68 85962.68 425.61 3.798 3.798 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 21.00 21.00 0.00777 -6.30 0.00230 0.872 0.00
PERIMETER_TOP_ZN_3 18165.57 18165.57 57.96 0.803 0.803 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 21.00 21.00 0.00782 -6.30 0.00230 0.135 0.00
PERIMETER_TOP_ZN_2 11850.94 11850.94 58.68 0.524 0.524 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 21.00 21.00 0.00782 -6.30 0.00230 0.087 0.00
PERIMETER_TOP_ZN_1 17970.66 17970.66 57.34 0.795 0.795 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 21.00 21.00 0.00782 -6.30 0.00230 0.135 0.00
PERIMETER_TOP_ZN_4 11580.09 11580.09 57.33 0.512 0.512 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 21.00 21.00 0.00781 -6.30 0.00230 0.087 0.00
DATACENTER_BOT_ZN_6 0.00 0.00 0.00 0.000 0.016 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 06:20:00 18.00 25.90 0.00847 -6.30 0.00230 0.016 0.00
DATACENTER_MID_ZN_6 0.00 0.00 0.00 0.000 0.156 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 05:40:00 18.00 23.13 0.00452 -6.30 0.00230 0.156 0.00
DATACENTER_TOP_ZN_6 0.00 0.00 0.00 0.000 0.016 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 05:40:00 18.00 21.19 0.00275 -6.30 0.00230 0.016 0.00
DATACENTER_BASEMENT_ZN_6 0.00 0.00 0.00 0.000 0.338 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 03:40:00 18.00 27.00 0.00850 -6.30 0.00230 0.338 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s] Adjusted cooling [m3/s] Adjusted heating [m3/s] Adjusted main [m3/s] Calculated Heating Air Flow Ratio [] User Heating Air Flow Ratio []
VAV_BOT WITH REHEAT 8.63 8.63 2.23 2.23 8.6311 2.7456 8.6311 0.3181 0.3000
VAV_MID WITH REHEAT 79.89 79.89 30.64 30.64 79.8945 30.6370 79.8945 0.3835 0.3000
VAV_TOP WITH REHEAT 8.57 8.57 5.21 5.21 8.5710 5.2106 8.5710 0.6079 0.3000
CAV_BAS 4.95 4.95 1.20 1.20 4.9470 4.9470 4.9470 1.0000 1.0000
AIRLOOP DATACENTER BOT 0.47 0.47 0.02 0.02 0.4738 0.4738 0.4738 1.0000 1.0000
AIRLOOP DATACENTER MID 4.50 4.50 0.16 0.16 4.5046 4.5046 4.5046 1.0000 1.0000
AIRLOOP DATACENTER TOP 0.46 0.46 0.02 0.02 0.4573 0.4573 0.4573 1.0000 1.0000


Plant Loop Coincident Design Fluid Flow Rate Adjustments

Previous Design Volume Flow Rate [m3/s] Algorithm Volume Flow Rate [m3/s] Coincident Design Volume Flow Rate [m3/s] Coincident Size Adjusted Peak Sizing Period Name Peak Day into Period {TIMESTAMP}[day] Peak Hour Of Day {TIMESTAMP}[hr] Peak Step Start Minute {TIMESTAMP}[min]
None                


Coil Sizing Summary

Coil Type HVAC Type HVAC Name Coil Final Gross Total Capacity [W] Coil Final Gross Sensible Capacity [W] Coil Final Reference Air Volume Flow Rate [m3/s] Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] Coil U-value Times Area Value [W/K] Design Day Name at Sensible Ideal Loads Peak Date/Time at Sensible Ideal Loads Peak Design Day Name at Air Flow Ideal Loads Peak Date/Time at Air Flow Ideal Loads Peak Coil Total Capacity at Ideal Loads Peak [W] Coil Sensible Capacity at Ideal Loads Peak [W] Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] Coil Entering Air Drybulb at Ideal Loads Peak [C] Coil Entering Air Wetbulb at Ideal Loads Peak [C] Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Leaving Air Drybulb at Ideal Loads Peak [C] Coil Leaving Air Wetbulb at Ideal Loads Peak [C] Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Drybulb at Ideal Loads Peak [C] Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Wetbulb at Ideal Loads Peak [C] Outdoor Air Flow Percentage at Ideal Loads Peak [%] Zone Air Drybulb at Ideal Loads Peak [C] Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Relative Humidity at Ideal Loads Peak [%] Zone Sensible Heat Gain at Ideal Loads Peak [W] Zone Latent Heat Gain at Ideal Loads Peak [W] Coil Total Capacity at Rating Conditions [W] Coil Sensible Capacity at Rating Conditions [W]
CORE_BOTTOM VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT CORE_BOTTOM VAV BOX 18165.300 18165.300 1.871233 0.00015892 366.198 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 06:20:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 06:20:00 18165.30 18165.30 1.871233 12.80 11.27 0.00800000 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 0.0000 21.00 0.00800000 49.8624 0.00 0.00 18232.28 18232.28
CORE_MID VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT CORE_MID VAV BOX 418017.035 418017.035 18.232477 0.00365700 9750.670 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 418017.04 418017.04 18.232477 12.80 11.27 0.00800000 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 0.0000 21.00 0.00800000 49.8624 241022.25 0.00 419392.73 419392.73
CORE_TOP VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT CORE_TOP VAV BOX 83477.024 83477.024 2.576355 0.00073029 2203.931 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 83477.02 83477.02 2.576355 12.80 11.27 0.00800000 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 0.0000 21.00 0.00800000 49.8624 58466.64 0.00 83768.31 83768.31
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_BOT_ZN_3 VAV BOX 11065.205 11065.205 0.341672 0.00009680 292.074 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 11065.20 11065.20 0.341672 12.80 11.27 0.00800000 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 0.0000 21.00 0.00766072 47.7762 7750.80 0.00 11103.35 11103.35
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_BOT_ZN_2 VAV BOX 7705.642 7705.642 0.238007 0.00006741 203.368 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 7705.64 7705.64 0.238007 12.80 11.27 0.00800000 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 0.0000 21.00 0.00770559 48.0524 5396.64 0.00 7732.00 7732.00
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_BOT_ZN_1 VAV BOX 13018.231 13018.231 0.402196 0.00011389 343.540 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 13018.23 13018.23 0.402196 12.80 11.27 0.00800000 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 0.0000 21.00 0.00776621 48.4254 9115.86 0.00 13062.49 13062.49
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_BOT_ZN_4 VAV BOX 6029.758 6029.758 0.229548 0.00005275 146.622 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 6029.76 6029.76 0.229548 12.80 11.27 0.00800000 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 0.0000 21.00 0.00742132 46.3015 3804.07 0.00 6049.21 6049.21
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_MID_ZN_3 VAV BOX 196410.774 196410.774 6.074573 0.00171829 5180.581 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 196410.77 196410.77 6.074573 12.80 11.27 0.00800000 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 0.0000 21.00 0.00779134 48.5805 137469.40 0.00 197060.29 197060.29
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_MID_ZN_2 VAV BOX 128817.450 128817.450 3.984213 0.00112695 3397.660 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 128817.45 128817.45 3.984213 12.80 11.27 0.00800000 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 0.0000 21.00 0.00779019 48.5735 90158.89 0.00 129242.99 129242.99
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_MID_ZN_1 VAV BOX 194062.319 194062.319 6.001779 0.00169774 5118.701 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 194062.32 194062.32 6.001779 12.80 11.27 0.00800000 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 0.0000 21.00 0.00778711 48.5545 135827.79 0.00 194704.53 194704.53
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_MID_ZN_4 VAV BOX 122814.766 122814.766 3.798191 0.00107444 3239.476 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 122814.77 122814.77 3.798191 12.80 11.27 0.00800000 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 0.0000 21.00 0.00777160 48.4591 85962.68 0.00 123221.50 123221.50
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_TOP_ZN_3 VAV BOX 25960.817 25960.817 0.803344 0.00022712 684.581 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 25960.82 25960.82 0.803344 12.80 11.27 0.00800000 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 0.0000 21.00 0.00782209 48.7699 18165.57 0.00 26045.46 26045.46
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_TOP_ZN_2 VAV BOX 16936.528 16936.528 0.524104 0.00014817 446.608 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 16936.53 16936.53 0.524104 12.80 11.27 0.00800000 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 0.0000 21.00 0.00781855 48.7481 11850.94 0.00 16991.71 16991.71
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_TOP_ZN_1 VAV BOX 25682.013 25682.013 0.794702 0.00022468 677.235 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 25682.01 25682.01 0.794702 12.80 11.27 0.00800000 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 0.0000 21.00 0.00782000 48.7570 17970.66 0.00 25765.79 25765.79
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL COIL:HEATING:WATER ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_TOP_ZN_4 VAV BOX 16549.157 16549.157 0.512101 0.00014478 436.399 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 16549.16 16549.16 0.512101 12.80 11.27 0.00800000 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 0.0000 21.00 0.00781366 48.7181 11580.09 0.00 16603.13 16603.13
VAV_BOT WITH REHEAT COOLING COIL Coil:Cooling:Water AirLoopHVAC VAV_BOT WITH REHEAT 222106.685 -999.000 8.631138 0.00944893 -999.000 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 222106.69 166884.01 8.631138 27.24 18.82 0.01064318 10.88 10.88 0.00850000 34.40 0.01447326 23.54 29.4074 24.00 0.00890997 46.2163 108110.70 0.00 227294.50 162939.65
VAV_BOT WITH REHEAT HEATING COIL Coil:Heating:Water AirLoopHVAC VAV_BOT WITH REHEAT 56676.840 56676.840 2.589342 0.00049583 919.086 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 56676.84 56676.84 2.589342 -5.96 -5.98 0.00235258 12.80 11.27 0.00800000 -6.30 0.00229779 -6.30 98.0245 21.15 0.00593439 36.7801 26067.37 0.00 51170.61 51170.61
VAV_MID WITH REHEAT COOLING COIL Coil:Cooling:Water AirLoopHVAC VAV_MID WITH REHEAT 2160566.932 -999.000 79.894474 0.09191551 -999.000 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 2160566.93 1584400.13 79.894474 27.66 19.16 0.01091595 10.88 10.88 0.00850000 34.40 0.01447326 23.54 31.7693 24.00 0.00898227 46.5863 956425.83 0.00 2209621.06 1551361.11
VAV_MID WITH REHEAT HEATING COIL Coil:Heating:Water AirLoopHVAC VAV_MID WITH REHEAT 534071.933 534071.933 23.968342 0.00467229 8644.990 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 14:40:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 534071.93 534071.93 23.968342 -6.30 -6.30 0.00229779 12.80 11.27 0.00800000 -6.30 0.00229779 -6.30 105.8978 21.00 0.00782917 48.8125 482353.39 0.00 480337.15 480337.15
VAV_TOP WITH REHEAT COOLING COIL Coil:Cooling:Water AirLoopHVAC VAV_TOP WITH REHEAT 217377.976 -999.000 8.571009 0.00924776 -999.000 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 16:00:00 217377.98 164323.41 8.571009 27.10 18.73 0.01057343 10.88 10.88 0.00850000 34.40 0.01447326 23.54 29.6137 24.00 0.00891616 46.2483 112937.67 0.00 222498.34 160310.88
VAV_TOP WITH REHEAT HEATING COIL Coil:Heating:Water AirLoopHVAC VAV_TOP WITH REHEAT 56240.194 56240.194 2.571303 0.00049201 912.069 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 22:10:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 56240.19 56240.19 2.571303 -5.95 -5.95 0.00236904 12.80 11.27 0.00800000 -6.30 0.00229779 -6.30 98.7122 19.79 0.00782922 52.5840 56966.15 0.00 50784.45 50784.45
CAV_BAS COOLING COIL Coil:Cooling:Water AirLoopHVAC CAV_BAS 118266.116 -999.000 4.947048 0.00503131 -999.000 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 12:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 118266.12 88991.94 4.947048 26.47 18.49 0.01053108 11.37 11.18 0.00850000 33.16 0.01447100 23.21 24.2607 24.00 0.00907295 47.0498 58959.59 0.00 121144.80 87315.66
CAV_BAS HEATING COIL Coil:Heating:Water AirLoopHVAC CAV_BAS 239673.490 239673.490 4.947048 0.00209677 5305.819 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 239673.49 239673.49 4.947048 -1.53 -3.37 0.00229779 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 24.2607 23.83 0.00229779 12.1691 0.00 0.00 199329.20 199329.20
AIRLOOP DATACENTER BOT COOLING COIL COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AirLoopHVAC AIRLOOP DATACENTER BOT 9347.238 6482.340 0.473781 0.00022891 -999.000 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:20:00 8657.96 8308.65 -999.0 28.10 17.65 0.00878663 12.80 11.77 0.00850000 30.70 0.01446650 22.54 -999.0000 27.00 0.00859143 37.3108 7915.65 0.00 -999.00 -999.00
AIRLOOP DATACENTER MID COOLING COIL COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AirLoopHVAC AIRLOOP DATACENTER MID 89037.508 61684.770 4.504638 0.00218052 -999.000 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:10:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:20:00 82497.15 79012.00 -999.0 28.10 17.66 0.00880072 12.80 11.77 0.00850000 30.52 0.01446618 22.49 -999.0000 27.00 0.00859605 37.3309 75430.30 0.00 -999.00 -999.00
AIRLOOP DATACENTER TOP COOLING COIL COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AirLoopHVAC AIRLOOP DATACENTER TOP 9033.639 6260.532 0.457306 0.00022123 -999.000 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 8369.26 8022.37 -999.0 28.11 17.66 0.00879486 12.80 11.77 0.00850000 30.70 0.01446650 22.54 -999.0000 27.00 0.00859412 37.3225 7693.76 0.00 -999.00 -999.00
AIRLOOP DATACENTER BOT HEATING COIL COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT AirLoopHVAC AIRLOOP DATACENTER BOT 9347.238 9347.238 0.473781 0.00022891 -999.000 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 9347.24 9347.24 0.473781 -6.30 -6.30 0.00229779 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 3.2996 26.33 0.00846714 38.2503 0.00 0.00 -999.00 -999.00
AIRLOOP DATACENTER MID HEATING COIL COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT AirLoopHVAC AIRLOOP DATACENTER MID 89037.508 89037.508 4.504638 0.00218052 -999.000 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 89037.51 89037.51 4.504638 -6.30 -6.30 0.00229779 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 3.4704 24.34 0.00452197 23.1462 0.00 0.00 -999.00 -999.00
AIRLOOP DATACENTER TOP HEATING COIL COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT AirLoopHVAC AIRLOOP DATACENTER TOP 9033.639 9033.639 0.457306 0.00022123 -999.000 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 9033.64 9033.64 0.457306 -6.30 -6.30 0.00229779 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 3.4184 23.07 0.00275464 15.2608 0.00 0.00 -999.00 -999.00
AIRLOOP DATACENTER BOT_SUPPHEATCOIL Coil:Heating:Electric AirLoopHVAC AIRLOOP DATACENTER BOT 844.396 844.396 -999.0 -999.0 -999.000 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 844.40 844.40 0.473781 -0.21 -0.21 0.00826357 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 3.2996 26.33 0.00846714 38.2503 0.00 0.00 -999.00 -999.00
AIRLOOP DATACENTER MID_SUPPHEATCOIL Coil:Heating:Electric AirLoopHVAC AIRLOOP DATACENTER MID 8443.956 8443.956 -999.0 -999.0 -999.000 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 8443.96 8443.96 4.504638 -0.22 -0.22 0.00444478 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 3.4704 24.34 0.00452197 23.1462 0.00 0.00 -999.00 -999.00
AIRLOOP DATACENTER TOP_SUPPHEATCOIL Coil:Heating:Electric AirLoopHVAC AIRLOOP DATACENTER TOP 844.396 844.396 -999.0 -999.0 -999.000 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 844.40 844.40 0.457306 -0.22 -1.90 0.00273902 40.00 20.76 0.00800000 -6.30 0.00229779 -6.30 3.4184 23.07 0.00275464 15.2608 0.00 0.00 -999.00 -999.00



Table of Contents

Report: Coil Sizing Details

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Coils

Coil Type Coil Location HVAC Type HVAC Name Zone Name(s) System Sizing Method Concurrence System Sizing Method Capacity System Sizing Method Air Flow Autosized Coil Capacity? Autosized Coil Airflow? Autosized Coil Water Flow? OA Pretreated prior to coil inlet? Coil Final Gross Total Capacity [W] Coil Final Gross Sensible Capacity [W] Coil Final Reference Air Volume Flow Rate [m3/s] Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] Coil U-value Times Area Value [W/K] Terminal Unit Reheat Coil Multiplier DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio Moist Air Heat Capacity [J/kg-K] Dry Air Heat Capacity [J/kg-K] Standard Air Density Adjusted for Elevation [kg/m3] Supply Fan Name for Coil Supply Fan Type for Coil Supply Fan Maximum Air Volume Flow Rate [m3/s] Supply Fan Maximum Air Mass Flow Rate [kg/s] Plant Name for Coil Plant Fluid Specific Heat Capacity [J/kg-K] Plant Fluid Density [kg/m3] Plant Maximum Fluid Mass Flow Rate [kg/s] Plant Design Fluid Return Temperature [C] Plant Design Fluid Supply Temperature [C] Plant Design Fluid Temperature Difference [deltaC] Plant Design Capacity [W] Coil Capacity Percentage of Plant Design Capacity [%] Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] Design Day Name at Sensible Ideal Loads Peak Date/Time at Sensible Ideal Loads Peak Design Day Name at Total Ideal Loads Peak Date/Time at Total Ideal Loads Peak Design Day Name at Air Flow Ideal Loads Peak Date/Time at Air Flow Ideal Loads Peak Peak Load Type to Size On Coil Total Capacity at Ideal Loads Peak [W] Coil Sensible Capacity at Ideal Loads Peak [W] Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] Coil Entering Air Drybulb at Ideal Loads Peak [C] Coil Entering Air Wetbulb at Ideal Loads Peak [C] Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] Coil Leaving Air Drybulb at Ideal Loads Peak [C] Coil Leaving Air Wetbulb at Ideal Loads Peak [C] Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] Supply Fan Air Heat Gain at Ideal Loads Peak [W] Coil and Fan Net Total Capacity at Ideal Loads Peak [W] Outdoor Air Drybulb at Ideal Loads Peak [C] Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Wetbulb at Ideal Loads Peak [C] Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] Outdoor Air Flow Percentage at Ideal Loads Peak [%] System Return Air Drybulb at Ideal Loads Peak [C] System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Drybulb at Ideal Loads Peak [C] Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Relative Humidity at Ideal Loads Peak [%] Zone Sensible Heat Gain at Ideal Loads Peak [W] Zone Latent Heat Gain at Ideal Loads Peak [W] Coil Total Capacity at Rating Conditions [W] Coil Sensible Capacity at Rating Conditions [W] Coil Air Mass Flow Rate at Rating Conditions [kg/s] Coil Entering Air Drybulb at Rating Conditions [C] Coil Entering Air Wetbulb at Rating Conditions [C] Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] Coil Leaving Air Drybulb at Rating Conditions [C] Coil Leaving Air Wetbulb at Rating Conditions [C] Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K]
CORE_BOTTOM VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT CORE_BOTTOM VAV BOX CORE_BOTTOM N/A N/A N/A Yes Yes Yes No 18165.300 18165.300 1.871233 0.00015892 366.198 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 0.8201 0.836581 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 06:20:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 06:20:00 Sensible 18165.30 18165.30 1.0000 2.17245781 1.871233 12.80 11.27 0.00800000 33059.8 40.00 20.76 0.00800000 60796.0 0.15890175 60.00 32.22 27.78 0.000 18165.30 -6.30 0.00229779 -6.30 0.00000000 0.0000 21.00 0.00800000 21.00 0.00800000 49.8624 0.00 0.00 18232.28 18232.28 2.17245781 12.80 11.60 0.00800000 33059.8 21.03 14.86 0.00800000 41452.3
CORE_MID VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT CORE_MID VAV BOX CORE_MID N/A N/A N/A Yes Yes Yes No 418017.035 418017.035 18.232477 0.00365700 9750.670 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 18.8715 19.251264 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 418017.04 418017.04 1.0000 21.16747830 18.232477 12.80 11.27 0.00800000 33059.8 40.00 20.76 0.00800000 60796.0 3.65662233 60.00 32.22 27.78 0.000 418017.04 -6.30 0.00229779 -6.30 0.00000000 0.0000 20.85 0.00800000 21.00 0.00800000 49.8624 241022.25 0.00 419392.73 419392.73 21.16747830 12.80 11.60 0.00800000 33059.8 32.23 18.77 0.00800000 52872.9
CORE_TOP VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT CORE_TOP VAV BOX CORE_TOP N/A N/A N/A Yes Yes Yes No 83477.024 83477.024 2.576355 0.00073029 2203.931 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 3.7686 3.844432 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 83477.02 83477.02 1.0000 2.99108732 2.576355 12.80 11.27 0.00800000 33059.8 40.00 20.76 0.00800000 60796.0 0.73021893 60.00 32.22 27.78 0.000 83477.02 -6.30 0.00229779 -6.30 0.00000000 0.0000 20.91 0.00800000 21.00 0.00800000 49.8624 58466.64 0.00 83768.31 83768.31 2.99108732 12.80 11.60 0.00800000 33059.8 40.26 21.26 0.00800000 61065.8
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_BOT_ZN_3 VAV BOX PERIMETER_BOT_ZN_3 N/A N/A N/A Yes Yes Yes No 11065.205 11065.205 0.341672 0.00009680 292.074 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 0.4995 0.509594 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 11065.20 11065.20 1.0000 0.39667322 0.341672 12.80 11.27 0.00800000 33059.8 40.00 20.76 0.00800000 60796.0 0.09679336 60.00 32.22 27.78 0.000 11065.20 -6.30 0.00229779 -6.30 0.00000000 0.0000 20.91 0.00766072 21.00 0.00766072 47.7762 7750.80 0.00 11103.35 11103.35 0.39667322 12.80 11.60 0.00800000 33059.8 40.25 21.26 0.00800000 61051.0
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_BOT_ZN_2 VAV BOX PERIMETER_BOT_ZN_2 N/A N/A N/A Yes Yes Yes No 7705.642 7705.642 0.238007 0.00006741 203.368 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 0.3479 0.354874 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 7705.64 7705.64 1.0000 0.27632037 0.238007 12.80 11.27 0.00800000 33059.8 40.00 20.76 0.00800000 60796.0 0.06740544 60.00 32.22 27.78 0.000 7705.64 -6.30 0.00229779 -6.30 0.00000000 0.0000 20.91 0.00770559 21.00 0.00770559 48.0524 5396.64 0.00 7732.00 7732.00 0.27632037 12.80 11.60 0.00800000 33059.8 40.24 21.25 0.00800000 61041.9
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_BOT_ZN_1 VAV BOX PERIMETER_BOT_ZN_1 N/A N/A N/A Yes Yes Yes No 13018.231 13018.231 0.402196 0.00011389 343.540 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 0.5877 0.599539 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 13018.23 13018.23 1.0000 0.46694023 0.402196 12.80 11.27 0.00800000 33059.8 40.00 20.76 0.00800000 60796.0 0.11387754 60.00 32.22 27.78 0.000 13018.23 -6.30 0.00229779 -6.30 0.00000000 0.0000 20.91 0.00776621 21.00 0.00776621 48.4254 9115.86 0.00 13062.49 13062.49 0.46694023 12.80 11.60 0.00800000 33059.8 40.23 21.25 0.00800000 61034.5
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_BOT_ZN_4 VAV BOX PERIMETER_BOT_ZN_4 N/A N/A N/A Yes Yes Yes No 6029.758 6029.758 0.229548 0.00005275 146.622 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 0.2722 0.277693 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 6029.76 6029.76 1.0000 0.26649929 0.229548 12.80 11.27 0.00800000 33059.8 40.00 20.76 0.00800000 60796.0 0.05274557 60.00 32.22 27.78 0.000 6029.76 -6.30 0.00229779 -6.30 0.00000000 0.0000 20.92 0.00742132 21.00 0.00742132 46.3015 3804.07 0.00 6049.21 6049.21 0.26649929 12.80 11.60 0.00800000 33059.8 35.06 19.68 0.00800000 55758.6
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_MID_ZN_3 VAV BOX PERIMETER_MID_ZN_3 N/A N/A N/A Yes Yes Yes No 196410.774 196410.774 6.074573 0.00171829 5180.581 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 8.8670 9.045458 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 196410.77 196410.77 1.0000 7.05243671 6.074573 12.80 11.27 0.00800000 33059.8 40.00 20.76 0.00800000 60796.0 1.71811185 60.00 32.22 27.78 0.000 196410.77 -6.30 0.00229779 -6.30 0.00000000 0.0000 20.95 0.00779134 21.00 0.00779134 48.5805 137469.40 0.00 197060.29 197060.29 7.05243671 12.80 11.60 0.00800000 33059.8 40.20 21.24 0.00800000 61002.0
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_MID_ZN_2 VAV BOX PERIMETER_MID_ZN_2 N/A N/A N/A Yes Yes Yes No 128817.450 128817.450 3.984213 0.00112695 3397.660 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 5.8155 5.932530 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 128817.45 128817.45 1.0000 4.62557770 3.984213 12.80 11.27 0.00800000 33059.8 40.00 20.76 0.00800000 60796.0 1.12683629 60.00 32.22 27.78 0.000 128817.45 -6.30 0.00229779 -6.30 0.00000000 0.0000 20.95 0.00779019 21.00 0.00779019 48.5735 90158.89 0.00 129242.99 129242.99 4.62557770 12.80 11.60 0.00800000 33059.8 40.20 21.24 0.00800000 61000.8
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_MID_ZN_1 VAV BOX PERIMETER_MID_ZN_1 N/A N/A N/A Yes Yes Yes No 194062.319 194062.319 6.001779 0.00169774 5118.701 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 8.7610 8.937303 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 194062.32 194062.32 1.0000 6.96792406 6.001779 12.80 11.27 0.00800000 33059.8 40.00 20.76 0.00800000 60796.0 1.69756864 60.00 32.22 27.78 0.000 194062.32 -6.30 0.00229779 -6.30 0.00000000 0.0000 20.95 0.00778711 21.00 0.00778711 48.5545 135827.79 0.00 194704.53 194704.53 6.96792406 12.80 11.60 0.00800000 33059.8 40.20 21.24 0.00800000 61002.8
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_MID_ZN_4 VAV BOX PERIMETER_MID_ZN_4 N/A N/A N/A Yes Yes Yes No 122814.766 122814.766 3.798191 0.00107444 3239.476 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 5.5445 5.656084 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 122814.77 122814.77 1.0000 4.40961085 3.798191 12.80 11.27 0.00800000 33059.8 40.00 20.76 0.00800000 60796.0 1.07432754 60.00 32.22 27.78 0.000 122814.77 -6.30 0.00229779 -6.30 0.00000000 0.0000 20.95 0.00777160 21.00 0.00777160 48.4591 85962.68 0.00 123221.50 123221.50 4.40961085 12.80 11.60 0.00800000 33059.8 40.20 21.24 0.00800000 61003.7
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_TOP_ZN_3 VAV BOX PERIMETER_TOP_ZN_3 N/A N/A N/A Yes Yes Yes No 25960.817 25960.817 0.803344 0.00022712 684.581 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 1.1720 1.195594 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 25960.82 25960.82 1.0000 0.93266349 0.803344 12.80 11.27 0.00800000 33059.8 40.00 20.76 0.00800000 60796.0 0.22709338 60.00 32.22 27.78 0.000 25960.82 -6.30 0.00229779 -6.30 0.00000000 0.0000 20.95 0.00782209 21.00 0.00782209 48.7699 18165.57 0.00 26045.46 26045.46 0.93266349 12.80 11.60 0.00800000 33059.8 40.19 21.24 0.00800000 60985.7
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_TOP_ZN_2 VAV BOX PERIMETER_TOP_ZN_2 N/A N/A N/A Yes Yes Yes No 16936.528 16936.528 0.524104 0.00014817 446.608 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 0.7646 0.779991 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 16936.53 16936.53 1.0000 0.60847224 0.524104 12.80 11.27 0.00800000 33059.8 40.00 20.76 0.00800000 60796.0 0.14815302 60.00 32.22 27.78 0.000 16936.53 -6.30 0.00229779 -6.30 0.00000000 0.0000 20.95 0.00781855 21.00 0.00781855 48.7481 11850.94 0.00 16991.71 16991.71 0.60847224 12.80 11.60 0.00800000 33059.8 40.19 21.24 0.00800000 60985.0
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_TOP_ZN_1 VAV BOX PERIMETER_TOP_ZN_1 N/A N/A N/A Yes Yes Yes No 25682.013 25682.013 0.794702 0.00022468 677.235 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 1.1594 1.182754 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 25682.01 25682.01 1.0000 0.92263000 0.794702 12.80 11.27 0.00800000 33059.8 40.00 20.76 0.00800000 60796.0 0.22465454 60.00 32.22 27.78 0.000 25682.01 -6.30 0.00229779 -6.30 0.00000000 0.0000 20.95 0.00782000 21.00 0.00782000 48.7570 17970.66 0.00 25765.79 25765.79 0.92263000 12.80 11.60 0.00800000 33059.8 40.19 21.24 0.00800000 60986.3
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL COIL:HEATING:WATER Zone Equipment ZONEHVAC:AIRDISTRIBUTIONUNIT PERIMETER_TOP_ZN_4 VAV BOX PERIMETER_TOP_ZN_4 N/A N/A N/A Yes Yes Yes No 16549.157 16549.157 0.512101 0.00014478 436.399 1.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 0.7471 0.762151 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 16549.16 16549.16 1.0000 0.59453726 0.512101 12.80 11.27 0.00800000 33059.8 40.00 20.76 0.00800000 60796.0 0.14476448 60.00 32.22 27.78 0.000 16549.16 -6.30 0.00229779 -6.30 0.00000000 0.0000 20.95 0.00781366 21.00 0.00781366 48.7181 11580.09 0.00 16603.13 16603.13 0.59453726 12.80 11.60 0.00800000 33059.8 40.19 21.24 0.00800000 60986.0
VAV_BOT WITH REHEAT COOLING COIL Coil:Cooling:Water AirLoop AirLoopHVAC VAV_BOT WITH REHEAT CORE_BOTTOM; PERIMETER_BOT_ZN_3; PERIMETER_BOT_ZN_2; PERIMETER_BOT_ZN_1; PERIMETER_BOT_ZN_4; Coincident CoolingDesignCapacity N/A Yes Yes Yes No 222106.685 -999.000 8.631138 0.00944893 -999.000 -999.0000 1.00000 1.00000 1024.6251 1004.8586 1.1610 VAV_BOT WITH REHEAT FAN Fan:VariableVolume 8.631138 10.02054927   4197.9300 999.8980 115.63172241 12.27 6.67 5.60 2718317.71 8.1707 8.170740 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 Sensible 222106.69 166884.01 1.0000 10.02054927 8.631138 27.24 18.82 0.01064318 54527.9 10.88 10.88 0.00850000 32362.8 9.44796794 6.67 12.27 5.60 19711.171 202395.51 34.40 0.01447326 23.54 2.53819000 29.4074 24.00 0.00890997 24.00 0.00890997 46.2163 108110.70 0.00 227294.50 162939.65 10.02054927 27.24 19.23 0.01064318 54527.9 11.37 11.09 0.00809675 31845.1
VAV_BOT WITH REHEAT HEATING COIL Coil:Heating:Water AirLoop AirLoopHVAC VAV_BOT WITH REHEAT CORE_BOTTOM; PERIMETER_BOT_ZN_3; PERIMETER_BOT_ZN_2; PERIMETER_BOT_ZN_1; PERIMETER_BOT_ZN_4; Coincident HeatingDesignCapacity N/A Yes Yes Yes No 56676.840 56676.840 2.589342 0.00049583 919.086 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 VAV_BOT WITH REHEAT FAN Fan:VariableVolume 8.631138 10.02054927   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 2.5587 2.610183 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 56676.84 56676.84 1.0000 3.00616478 2.589342 -5.96 -5.98 0.00235258 -133.7 12.80 11.27 0.00800000 33059.8 0.49578314 60.00 32.22 27.78 0.000 56676.84 -6.30 0.00229779 -6.30 2.53819000 98.0245 10.79 0.00507106 21.15 0.00593439 36.7801 26067.37 0.00 51170.61 51170.61 3.00616478 2.80 -0.64 0.00235258 8709.5 19.67 8.51 0.00235258 25731.3
VAV_MID WITH REHEAT COOLING COIL Coil:Cooling:Water AirLoop AirLoopHVAC VAV_MID WITH REHEAT CORE_MID; PERIMETER_MID_ZN_3; PERIMETER_MID_ZN_2; PERIMETER_MID_ZN_1; PERIMETER_MID_ZN_4; Coincident CoolingDesignCapacity N/A Yes Yes Yes No 2160566.932 -999.000 79.894474 0.09191551 -999.000 -999.0000 1.00000 1.00000 1025.1322 1004.8586 1.1610 VAV_MID WITH REHEAT FAN Fan:VariableVolume 79.894474 92.75560954   4197.9300 999.8980 115.63172241 12.27 6.67 5.60 2718317.71 79.4818 79.481766 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 Sensible 2160566.93 1584400.13 1.0000 92.75560954 79.894474 27.66 19.16 0.01091595 55656.9 10.88 10.88 0.00850000 32363.7 91.90613553 6.67 12.27 5.60 182457.231 1978109.70 34.40 0.01447326 23.54 25.38195000 31.7693 24.00 0.00898227 24.00 0.00898227 46.5863 956425.83 0.00 2209621.06 1551361.11 92.75560954 27.66 19.57 0.01091595 55656.9 11.35 11.08 0.00810207 31834.9
VAV_MID WITH REHEAT HEATING COIL Coil:Heating:Water AirLoop AirLoopHVAC VAV_MID WITH REHEAT CORE_MID; PERIMETER_MID_ZN_3; PERIMETER_MID_ZN_2; PERIMETER_MID_ZN_1; PERIMETER_MID_ZN_4; Coincident HeatingDesignCapacity N/A Yes Yes Yes No 534071.933 534071.933 23.968342 0.00467229 8644.990 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 VAV_MID WITH REHEAT FAN Fan:VariableVolume 79.894474 92.75560954   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 24.1108 24.596031 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 14:40:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 534071.93 534071.93 1.0000 27.82668286 23.968342 -6.30 -6.30 0.00229779 -610.8 12.80 11.27 0.00800000 33059.8 4.67181763 60.00 32.22 27.78 0.000 534071.93 -6.30 0.00229779 -6.30 25.38195000 105.8978 21.00 0.00785571 21.00 0.00782917 48.8125 482353.39 0.00 480337.15 480337.15 27.82668286 2.80 -0.72 0.00229779 8572.2 19.91 8.56 0.00229779 25833.9
VAV_TOP WITH REHEAT COOLING COIL Coil:Cooling:Water AirLoop AirLoopHVAC VAV_TOP WITH REHEAT CORE_TOP; PERIMETER_TOP_ZN_3; PERIMETER_TOP_ZN_2; PERIMETER_TOP_ZN_1; PERIMETER_TOP_ZN_4; Coincident CoolingDesignCapacity N/A Yes Yes Yes No 217377.976 -999.000 8.571009 0.00924776 -999.000 -999.0000 1.00000 1.00000 1024.4955 1004.8586 1.1610 VAV_TOP WITH REHEAT FAN Fan:VariableVolume 8.571009 9.95074027   4197.9300 999.8980 115.63172241 12.27 6.67 5.60 2718317.71 7.9968 7.996783 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 16:00:00 Sensible 217377.98 164323.41 1.0000 9.95074027 8.571009 27.10 18.73 0.01057343 54207.9 10.88 10.88 0.00850000 32362.5 9.24681823 6.67 12.27 5.60 19573.851 197804.12 34.40 0.01447326 23.54 2.53819000 29.6137 24.00 0.00891616 24.00 0.00891616 46.2483 112937.67 0.00 222498.34 160310.88 9.95074027 27.10 19.13 0.01057343 54207.9 11.38 11.09 0.00809551 31848.0
VAV_TOP WITH REHEAT HEATING COIL Coil:Heating:Water AirLoop AirLoopHVAC VAV_TOP WITH REHEAT CORE_TOP; PERIMETER_TOP_ZN_3; PERIMETER_TOP_ZN_2; PERIMETER_TOP_ZN_1; PERIMETER_TOP_ZN_4; Coincident HeatingDesignCapacity N/A Yes Yes Yes No 56240.194 56240.194 2.571303 0.00049201 912.069 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 VAV_TOP WITH REHEAT FAN Fan:VariableVolume 8.571009 9.95074027   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 2.5390 2.590073 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 22:10:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 08:00:00 Sensible 56240.19 56240.19 1.0000 2.98522208 2.571303 -5.95 -5.95 0.00236904 -78.6 12.80 11.27 0.00800000 33059.8 0.49196356 60.00 32.22 27.78 0.000 56240.19 -6.30 0.00229779 -6.30 2.53819000 98.7122 21.00 0.00783037 19.79 0.00782922 52.5840 56966.15 0.00 50784.45 50784.45 2.98522208 2.80 -0.61 0.00236904 8750.7 19.66 8.53 0.00236904 25762.7
CAV_BAS COOLING COIL Coil:Cooling:Water AirLoop AirLoopHVAC CAV_BAS BASEMENT Coincident CoolingDesignCapacity N/A Yes Yes Yes No 118266.116 -999.000 4.947048 0.00503131 -999.000 -999.0000 1.00000 1.00000 1024.4167 1004.8586 1.1610 CAV_BAS FAN Fan:ConstantVolume 4.947048 5.74340666   4197.9300 999.8980 115.63172241 12.27 6.67 5.60 2718317.71 4.3507 4.350710 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 12:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 12:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 08:00:00 Sensible 118266.12 88991.94 1.0000 5.74340666 4.947048 26.47 18.49 0.01053108 53458.7 11.37 11.18 0.00850000 32867.0 5.03080071 6.67 12.27 5.60 8388.483 109877.63 33.16 0.01447100 23.21 1.20019084 24.2607 24.00 0.00907295 24.00 0.00907295 47.0498 58959.59 0.00 121144.80 87315.66 5.74340666 26.47 18.89 0.01053108 53458.7 11.63 11.30 0.00819612 32365.8
CAV_BAS HEATING COIL Coil:Heating:Water AirLoop AirLoopHVAC CAV_BAS BASEMENT Coincident HeatingDesignCapacity N/A Yes Yes Yes No 239673.490 239673.490 4.947048 0.00209677 5305.819 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 CAV_BAS FAN Fan:ConstantVolume 4.947048 5.74340666   4197.9300 999.8980 18.99419335 54.44 82.22 27.78 2215074.25 10.8201 11.037870 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 Sensible 239673.49 239673.49 1.0000 5.74340666 4.947048 -1.53 -3.37 0.00229779 4204.3 40.00 20.76 0.00800000 60796.0 2.09655435 60.00 32.22 27.78 0.000 239673.49 -6.30 0.00229779 -6.30 1.20019084 24.2607 0.00 0.00229779 23.83 0.00229779 12.1691 0.00 0.00 199329.20 199329.20 5.74340666 12.80 5.08 0.00229779 18663.3 47.19 19.08 0.00229779 53369.0
AIRLOOP DATACENTER BOT COOLING COIL COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AirLoop AirLoopHVAC AIRLOOP DATACENTER BOT DATACENTER_BOT_ZN_6 Coincident CoolingDesignCapacity N/A Yes No unknown No 9347.238 6482.340 0.473781 0.00022891 -999.000 -999.0000 -999.00000 -999.00000 1021.1739 1004.8586 1.1610 unknown unknown -999.0 -999.0   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:20:00 Sensible 8657.96 8308.65 0.9263 -999.0 -999.0 28.10 17.65 0.00878663 50672.4 12.80 11.77 0.00850000 34322.2 -999.0 -999.00 -999.00 -999.00 0.000 8657.96 30.70 0.01446650 22.54 0.01563279 -999.0000 27.00 0.00859143 27.00 0.00859143 37.3108 7915.65 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
AIRLOOP DATACENTER MID COOLING COIL COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AirLoop AirLoopHVAC AIRLOOP DATACENTER MID DATACENTER_MID_ZN_6 Coincident CoolingDesignCapacity N/A Yes No unknown No 89037.508 61684.770 4.504638 0.00218052 -999.000 -999.0000 -999.00000 -999.00000 1021.2001 1004.8586 1.1610 unknown unknown -999.0 -999.0   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:10:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:10:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:20:00 Sensible 82497.15 79012.00 0.9265 -999.0 -999.0 28.10 17.66 0.00880072 50708.2 12.80 11.77 0.00850000 34322.2 -999.0 -999.00 -999.00 -999.00 0.000 82497.15 30.52 0.01446618 22.49 0.15632792 -999.0000 27.00 0.00859605 27.00 0.00859605 37.3309 75430.30 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
AIRLOOP DATACENTER TOP COOLING COIL COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT AirLoop AirLoopHVAC AIRLOOP DATACENTER TOP DATACENTER_TOP_ZN_6 Coincident CoolingDesignCapacity N/A Yes No unknown No 9033.639 6260.532 0.457306 0.00022123 -999.000 -999.0000 -999.00000 -999.00000 1021.1892 1004.8586 1.1610 unknown unknown -999.0 -999.0   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 8369.26 8022.37 0.9265 -999.0 -999.0 28.11 17.66 0.00879486 50697.0 12.80 11.77 0.00850000 34322.2 -999.0 -999.00 -999.00 -999.00 0.000 8369.26 30.70 0.01446650 22.54 0.01563279 -999.0000 27.00 0.00859412 27.00 0.00859412 37.3225 7693.76 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
AIRLOOP DATACENTER BOT HEATING COIL COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT AirLoop AirLoopHVAC AIRLOOP DATACENTER BOT DATACENTER_BOT_ZN_6 Coincident HeatingDesignCapacity N/A Yes No unknown No 9347.238 9347.238 0.473781 0.00022891 -999.000 -999.0000 -999.00000 -999.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 Sensible 9347.24 9347.24 1.0000 0.55004822 0.473781 -6.30 -6.30 0.00229779 -610.8 40.00 20.76 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 9347.24 -6.30 0.00229779 -6.30 0.01563279 3.2996 0.00 0.00846714 26.33 0.00846714 38.2503 0.00 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
AIRLOOP DATACENTER MID HEATING COIL COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT AirLoop AirLoopHVAC AIRLOOP DATACENTER MID DATACENTER_MID_ZN_6 Coincident HeatingDesignCapacity N/A Yes No unknown No 89037.508 89037.508 4.504638 0.00218052 -999.000 -999.0000 -999.00000 -999.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 Sensible 89037.51 89037.51 1.0000 5.22977860 4.504638 -6.30 -6.30 0.00229779 -610.8 40.00 20.76 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 89037.51 -6.30 0.00229779 -6.30 0.15632792 3.4704 0.00 0.00452197 24.34 0.00452197 23.1462 0.00 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
AIRLOOP DATACENTER TOP HEATING COIL COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT AirLoop AirLoopHVAC AIRLOOP DATACENTER TOP DATACENTER_TOP_ZN_6 Coincident HeatingDesignCapacity N/A Yes No unknown No 9033.639 9033.639 0.457306 0.00022123 -999.000 -999.0000 -999.00000 -999.00000 1019.7116 1004.8586 1.1610 unknown unknown -999.0 -999.0   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 Sensible 9033.64 9033.64 1.0000 0.53092206 0.457306 -6.30 -6.30 0.00229779 -610.8 40.00 20.76 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 9033.64 -6.30 0.00229779 -6.30 0.01563279 3.4184 0.00 0.00275464 23.07 0.00275464 15.2608 0.00 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
AIRLOOP DATACENTER BOT_SUPPHEATCOIL Coil:Heating:Electric AirLoop AirLoopHVAC AIRLOOP DATACENTER BOT DATACENTER_BOT_ZN_6 Coincident HeatingDesignCapacity N/A Yes No unknown No 844.396 844.396 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 AIRLOOP DATACENTER BOT SUPPLY FAN Fan:OnOff 0.473781 0.55004822   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 Sensible 844.40 844.40 1.0000 0.55004822 0.473781 -0.21 -0.21 0.00826357 20454.6 40.00 20.76 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 844.40 -6.30 0.00229779 -6.30 0.01563279 3.2996 0.00 0.00846714 26.33 0.00846714 38.2503 0.00 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
AIRLOOP DATACENTER MID_SUPPHEATCOIL Coil:Heating:Electric AirLoop AirLoopHVAC AIRLOOP DATACENTER MID DATACENTER_MID_ZN_6 Coincident HeatingDesignCapacity N/A Yes No unknown No 8443.956 8443.956 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 AIRLOOP DATACENTER MID SUPPLY FAN Fan:OnOff 4.504638 5.22977860   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 Sensible 8443.96 8443.96 1.0000 5.22977860 4.504638 -0.22 -0.22 0.00444478 10894.6 40.00 20.76 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 8443.96 -6.30 0.00229779 -6.30 0.15632792 3.4704 0.00 0.00452197 24.34 0.00452197 23.1462 0.00 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
AIRLOOP DATACENTER TOP_SUPPHEATCOIL Coil:Heating:Electric AirLoop AirLoopHVAC AIRLOOP DATACENTER TOP DATACENTER_TOP_ZN_6 Coincident HeatingDesignCapacity N/A Yes No unknown No 844.396 844.396 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1610 AIRLOOP DATACENTER TOP SUPPLY FAN Fan:OnOff 0.457306 0.53092206   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 unknown unknown ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB 1/21 00:10:00 Sensible 844.40 844.40 1.0000 0.53092206 0.457306 -0.22 -1.90 0.00273902 6632.6 40.00 20.76 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 844.40 -6.30 0.00229779 -6.30 0.01563279 3.4184 0.00 0.00275464 23.07 0.00275464 15.2608 0.00 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
VAV_BOT WITH REHEAT_OA_CONTROLLER DifferentialEnthalpy 0.00 8.63 -      
VAV_MID WITH REHEAT_OA_CONTROLLER DifferentialEnthalpy 0.00 79.89 -      
VAV_TOP WITH REHEAT_OA_CONTROLLER DifferentialEnthalpy 0.00 8.57 -      
CAV_BAS_OA_CONTROLLER DifferentialEnthalpy 0.00 4.95 -      


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Outdoor Air Per Zone [m3/s] Outdoor Air ACH [ach] Outdoor Air Method Outdoor Air Schedule Name Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule Name
BASEMENT BASEMENT_DCV 0.002360 0.000305 0.000000 0.000000 Sum   1.00 1.00  
CORE_BOTTOM VAV_BOT WITH REHEAT_DCV 0.000000 0.000432 0.000000 0.000000 Flow/Area   1.00 1.00  
CORE_MID VAV_MID WITH REHEAT_DCV 0.000000 0.000432 0.000000 0.000000 Flow/Area   1.00 1.00  
CORE_TOP VAV_TOP WITH REHEAT_DCV 0.000000 0.000432 0.000000 0.000000 Flow/Area   1.00 1.00  
PERIMETER_BOT_ZN_3 VAV_BOT WITH REHEAT_DCV 0.000000 0.000432 0.000000 0.000000 Flow/Area   1.00 1.00  
PERIMETER_BOT_ZN_2 VAV_BOT WITH REHEAT_DCV 0.000000 0.000432 0.000000 0.000000 Flow/Area   1.00 1.00  
PERIMETER_BOT_ZN_1 VAV_BOT WITH REHEAT_DCV 0.000000 0.000432 0.000000 0.000000 Flow/Area   1.00 1.00  
PERIMETER_BOT_ZN_4 VAV_BOT WITH REHEAT_DCV 0.000000 0.000432 0.000000 0.000000 Flow/Area   1.00 1.00  
PERIMETER_MID_ZN_3 VAV_MID WITH REHEAT_DCV 0.000000 0.000432 0.000000 0.000000 Flow/Area   1.00 1.00  
PERIMETER_MID_ZN_2 VAV_MID WITH REHEAT_DCV 0.000000 0.000432 0.000000 0.000000 Flow/Area   1.00 1.00  
PERIMETER_MID_ZN_1 VAV_MID WITH REHEAT_DCV 0.000000 0.000432 0.000000 0.000000 Flow/Area   1.00 1.00  
PERIMETER_MID_ZN_4 VAV_MID WITH REHEAT_DCV 0.000000 0.000432 0.000000 0.000000 Flow/Area   1.00 1.00  
PERIMETER_TOP_ZN_3 VAV_TOP WITH REHEAT_DCV 0.000000 0.000432 0.000000 0.000000 Flow/Area   1.00 1.00  
PERIMETER_TOP_ZN_2 VAV_TOP WITH REHEAT_DCV 0.000000 0.000432 0.000000 0.000000 Flow/Area   1.00 1.00  
PERIMETER_TOP_ZN_1 VAV_TOP WITH REHEAT_DCV 0.000000 0.000432 0.000000 0.000000 Flow/Area   1.00 1.00  
PERIMETER_TOP_ZN_4 VAV_TOP WITH REHEAT_DCV 0.000000 0.000432 0.000000 0.000000 Flow/Area   1.00 1.00  


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
BASEMENT 3646.33 1820.33 1157.50
CORE_BOTTOM 3538.33 822.17 32.67
CORE_MID 2900.33 2203.17 66.50
CORE_TOP 3120.83 2834.17 536.67
PERIMETER_BOT_ZN_3 3085.17 2360.33 207.00
PERIMETER_BOT_ZN_2 3113.33 2337.33 250.33
PERIMETER_BOT_ZN_1 3346.17 1869.00 224.83
PERIMETER_BOT_ZN_4 3904.17 1340.50 369.50
PERIMETER_MID_ZN_3 3342.00 3155.67 923.67
PERIMETER_MID_ZN_2 2867.50 2560.67 783.17
PERIMETER_MID_ZN_1 3268.50 2316.33 452.33
PERIMETER_MID_ZN_4 3427.00 2763.50 687.00
PERIMETER_TOP_ZN_3 3740.50 3358.67 1485.83
PERIMETER_TOP_ZN_2 3758.00 3130.83 1327.50
PERIMETER_TOP_ZN_1 3512.83 2767.17 895.17
PERIMETER_TOP_ZN_4 3665.50 3048.83 1129.33
DATACENTER_BOT_ZN_6 5940.50 674.67 674.67
DATACENTER_MID_ZN_6 5710.67 53.00 35.83
DATACENTER_TOP_ZN_6 5354.50 333.50 134.00
DATACENTER_BASEMENT_ZN_6 5943.00 5875.50 5875.50
GROUNDFLOOR_PLENUM 0.00 0.00 0.00
MIDFLOOR_PLENUM 0.00 0.00 0.00
TOPFLOOR_PLENUM 0.00 0.00 0.00
Facility 5943.00 5943.00 5943.00
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
BASEMENT 0.00 89.50 0.00 8.00
CORE_BOTTOM 0.00 0.83 0.00 0.00
CORE_MID 0.00 0.00 0.00 0.00
CORE_TOP 5.67 0.00 0.83 0.00
PERIMETER_BOT_ZN_3 0.00 2.33 0.00 1.00
PERIMETER_BOT_ZN_2 0.00 21.83 0.00 21.67
PERIMETER_BOT_ZN_1 0.17 26.67 0.00 24.67
PERIMETER_BOT_ZN_4 0.00 149.83 0.00 48.00
PERIMETER_MID_ZN_3 8.83 0.00 1.00 0.00
PERIMETER_MID_ZN_2 5.17 25.83 0.17 25.67
PERIMETER_MID_ZN_1 2.00 19.67 0.17 19.67
PERIMETER_MID_ZN_4 3.00 38.50 0.17 18.17
PERIMETER_TOP_ZN_3 74.83 4.83 27.33 3.00
PERIMETER_TOP_ZN_2 34.33 38.33 3.83 32.17
PERIMETER_TOP_ZN_1 29.00 27.33 5.00 23.00
PERIMETER_TOP_ZN_4 22.33 46.00 2.00 20.33
DATACENTER_BOT_ZN_6 0.00 0.00 0.00 0.00
DATACENTER_MID_ZN_6 0.00 3.17 0.00 3.17
DATACENTER_TOP_ZN_6 0.00 2.67 0.00 2.67
DATACENTER_BASEMENT_ZN_6 0.00 0.00 0.00 0.00
GROUNDFLOOR_PLENUM 0.00 0.00 0.00 0.00
MIDFLOOR_PLENUM 0.00 0.00 0.00 0.00
TOPFLOOR_PLENUM 0.00 0.00 0.00 0.00
Facility 76.83 344.67 27.33 143.50
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
BASEMENT 60.99 149.60 6779.02 1.069 0.000 0.000 0.000
CORE_BOTTOM 54.77 134.35 6849.35 0.801 0.000 0.000 0.000
CORE_MID 54.77 134.35 6849.35 0.640 0.000 0.000 0.000
CORE_TOP 54.77 134.35 6849.35 0.607 0.000 0.000 0.000
PERIMETER_BOT_ZN_3 6.88 16.87 860.00 0.740 0.011 0.000 0.000
PERIMETER_BOT_ZN_2 4.43 10.87 554.22 0.948 0.011 0.000 0.000
PERIMETER_BOT_ZN_1 6.88 16.87 860.02 1.007 0.011 0.000 0.000
PERIMETER_BOT_ZN_4 4.43 10.87 554.22 1.501 0.011 0.000 0.000
PERIMETER_MID_ZN_3 6.88 16.87 860.00 0.653 0.025 0.000 0.000
PERIMETER_MID_ZN_2 3.86 10.87 554.22 0.850 0.028 0.000 0.000
PERIMETER_MID_ZN_1 6.88 16.87 860.02 0.921 0.025 0.000 0.000
PERIMETER_MID_ZN_4 4.43 10.87 554.22 0.983 0.026 0.000 0.000
PERIMETER_TOP_ZN_3 6.88 16.87 860.00 0.652 0.031 0.000 0.000
PERIMETER_TOP_ZN_2 4.43 10.87 554.22 0.927 0.033 0.000 0.000
PERIMETER_TOP_ZN_1 6.88 16.87 860.02 0.867 0.032 0.000 0.000
PERIMETER_TOP_ZN_4 4.43 10.87 554.22 0.988 0.033 0.000 0.000
DATACENTER_BOT_ZN_6 0.79 1.95 99.34 0.427 0.000 0.000 0.000
DATACENTER_MID_ZN_6 0.79 1.95 99.34 0.427 0.000 0.000 0.000
DATACENTER_TOP_ZN_6 0.79 1.95 99.34 0.426 0.000 0.000 0.000
DATACENTER_BASEMENT_ZN_6 17.20 42.18 1911.37 0.000 0.000 0.000 0.000
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
BASEMENT 60.99 149.60 6779.02 0.000 0.000 0.000 0.000
CORE_BOTTOM 54.77 134.35 6849.35 0.000 0.000 0.000 0.000
CORE_MID 54.77 134.35 6849.35 0.000 0.000 0.000 0.000
CORE_TOP 54.77 134.35 6849.35 0.000 0.000 0.000 0.000
PERIMETER_BOT_ZN_3 6.88 16.87 860.00 0.000 0.000 0.000 0.000
PERIMETER_BOT_ZN_2 4.43 10.87 554.22 0.000 0.000 0.000 0.000
PERIMETER_BOT_ZN_1 6.88 16.87 860.02 0.000 0.000 0.000 0.000
PERIMETER_BOT_ZN_4 4.43 10.87 554.22 0.000 0.000 0.000 0.000
PERIMETER_MID_ZN_3 6.88 16.87 860.00 0.000 0.000 0.000 0.000
PERIMETER_MID_ZN_2 3.86 10.87 554.22 0.000 0.000 0.000 0.000
PERIMETER_MID_ZN_1 6.88 16.87 860.02 0.000 0.000 0.000 0.000
PERIMETER_MID_ZN_4 4.43 10.87 554.22 0.000 0.000 0.000 0.000
PERIMETER_TOP_ZN_3 6.88 16.87 860.00 0.000 0.000 0.000 0.000
PERIMETER_TOP_ZN_2 4.43 10.87 554.22 0.000 0.000 0.000 0.000
PERIMETER_TOP_ZN_1 6.88 16.87 860.02 0.000 0.000 0.000 0.000
PERIMETER_TOP_ZN_4 4.43 10.87 554.22 0.000 0.000 0.000 0.000
DATACENTER_BOT_ZN_6 0.79 1.95 99.34 0.000 0.000 0.000 0.000
DATACENTER_MID_ZN_6 0.79 1.95 99.34 0.000 0.000 0.000 0.000
DATACENTER_TOP_ZN_6 0.79 1.95 99.34 0.000 0.000 0.000 0.000
DATACENTER_BASEMENT_ZN_6 17.20 42.18 1911.37 0.000 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Outdoor Air Details

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Mechanical Ventilation Parameters by Zone

AirLoop Name Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Zone Area [m2] Design Zone Outdoor Airflow - Voz [m3/s] Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s]
BASEMENT CAV_BAS 60.99 149.60 6779.02 2779.43 1.2002 0.847
CORE_BOTTOM VAV_BOT WITH REHEAT 54.77 134.35 6849.35 2496.12 0.0000 1.078
CORE_MID VAV_MID WITH REHEAT 54.77 134.35 6849.35 2496.12 0.0000 10.778
CORE_TOP VAV_TOP WITH REHEAT 54.77 134.35 6849.35 2496.12 0.0000 1.078
PERIMETER_BOT_ZN_3 VAV_BOT WITH REHEAT 6.88 16.87 860.00 313.41 0.0000 0.135
PERIMETER_BOT_ZN_2 VAV_BOT WITH REHEAT 4.43 10.87 554.22 201.98 0.0000 0.087
PERIMETER_BOT_ZN_1 VAV_BOT WITH REHEAT 6.88 16.87 860.02 313.42 0.0000 0.135
PERIMETER_BOT_ZN_4 VAV_BOT WITH REHEAT 4.43 10.87 554.22 201.98 0.0000 0.087
PERIMETER_MID_ZN_3 VAV_MID WITH REHEAT 6.88 16.87 860.00 313.41 0.0000 1.353
PERIMETER_MID_ZN_2 VAV_MID WITH REHEAT 3.86 10.87 554.22 201.98 0.0000 0.872
PERIMETER_MID_ZN_1 VAV_MID WITH REHEAT 6.88 16.87 860.02 313.42 0.0000 1.353
PERIMETER_MID_ZN_4 VAV_MID WITH REHEAT 4.43 10.87 554.22 201.98 0.0000 0.872
PERIMETER_TOP_ZN_3 VAV_TOP WITH REHEAT 6.88 16.87 860.00 313.41 0.0000 0.135
PERIMETER_TOP_ZN_2 VAV_TOP WITH REHEAT 4.43 10.87 554.22 201.98 0.0000 0.087
PERIMETER_TOP_ZN_1 VAV_TOP WITH REHEAT 6.88 16.87 860.02 313.42 0.0000 0.135
PERIMETER_TOP_ZN_4 VAV_TOP WITH REHEAT 4.43 10.87 554.22 201.98 0.0000 0.087
DATACENTER_BOT_ZN_6 AIRLOOP DATACENTER BOT 0.79 1.95 99.34 36.20 0.0156 0.011
DATACENTER_MID_ZN_6 AIRLOOP DATACENTER MID 0.79 1.95 99.34 36.20 0.1563 0.110
DATACENTER_TOP_ZN_6 AIRLOOP DATACENTER TOP 0.79 1.95 99.34 36.20 0.0156 0.011
DATACENTER_BASEMENT_ZN_6   17.20 42.18 1911.37 783.68   0.239
Total Facility   1010.73 2493.19 126016.35 46320.38 1.3878 157.549


Total Outdoor Air by Zone

Mechanical Ventilation [m3] Natural Ventilation [m3] Total Ventilation [m3] Infiltration [m3] Total Ventilation and Infiltration [m3] Dynamic Target Ventilation - Voz-dyn [m3] Time Below Voz-dyn [hr] Time At Voz-dyn [hr] Time Above Voz-dyn [hr] Time Above Zero When Unoccupied [hr]
BASEMENT 44446527.53 0.00 44446527.53 0.00 44446527.53 29876159.83 3964.19 1717.57 3078.24 295.77
CORE_BOTTOM 33800492.83 0.00 33800492.83 0.00 33800492.83 33990283.35 5418.09 225.60 3116.31 303.14
CORE_MID 0.26E+09 0.00 0.26E+09 0.00 0.26E+09 0.34E+09 5772.67 633.40 2353.93 94.62
CORE_TOP 24605539.25 0.00 24605539.25 0.00 24605539.25 33990283.35 6044.82 597.51 2117.67 180.36
PERIMETER_BOT_ZN_3 3925186.97 0.00 3925186.97 109831.58 4035018.55 4267819.30 4582.68 264.80 3912.52 303.14
PERIMETER_BOT_ZN_2 3226847.23 0.00 3226847.23 73221.00 3300068.23 2750345.05 4052.26 58.55 4649.19 303.14
PERIMETER_BOT_ZN_1 5268888.36 0.00 5268888.36 109831.58 5378719.94 4267912.63 4420.60 227.10 4112.30 303.14
PERIMETER_BOT_ZN_4 5082825.15 0.00 5082825.15 73221.00 5156046.15 2750345.05 3804.73 0.81 4954.46 303.14
PERIMETER_MID_ZN_3 33299349.16 0.00 33299349.16 257583.37 33556932.52 42678193.03 4621.38 649.62 3489.01 94.62
PERIMETER_MID_ZN_2 30492204.54 0.00 30492204.54 171722.13 30663926.66 27503450.52 4176.67 9.08 4574.26 1003.62
PERIMETER_MID_ZN_1 46696731.67 0.00 46696731.67 257583.37 46954315.04 42679126.28 4413.93 630.74 3715.33 94.62
PERIMETER_MID_ZN_4 32228897.70 0.00 32228897.70 171722.13 32400619.83 27503450.52 4148.84 3.27 4607.88 94.62
PERIMETER_TOP_ZN_3 3322409.89 0.00 3322409.89 319814.16 3642224.05 4267819.30 4763.70 604.00 3392.29 180.36
PERIMETER_TOP_ZN_2 3031875.85 0.00 3031875.85 213209.30 3245085.15 2750345.05 4231.31 7.28 4521.41 180.36
PERIMETER_TOP_ZN_1 4392975.25 0.00 4392975.25 319814.16 4712789.41 4267912.63 4586.91 664.57 3508.52 180.36
PERIMETER_TOP_ZN_4 3236991.73 0.00 3236991.73 213209.30 3450201.02 2750345.05 4211.40 3.22 4545.37 180.36
DATACENTER_BOT_ZN_6 244303.03 0.00 244303.03 0.00 244303.03 389144.62 4419.00 504.00 3837.00 0.00
DATACENTER_MID_ZN_6 2443030.26 0.00 2443030.26 0.00 2443030.26 3891446.16 4419.00 504.00 3837.00 0.00
DATACENTER_TOP_ZN_6 244303.03 0.00 244303.03 0.00 244303.03 389144.62 4419.00 504.00 3837.00 0.00
DATACENTER_BASEMENT_ZN_6 0.00 0.00 0.00 0.00 0.00 8423799.00 8760.00 0.00 0.00 0.00
Total Facility 0.42E+10 0.00 0.42E+10 10018261.95 0.42E+10 0.50E+10 8760.00 2728.04 5151.99 1496.40


Average Outdoor Air During Occupancy by Zone - Flow Rates

Mechanical Ventilation [m3/s] Natural Ventilation [m3/s] Total Ventilation [m3/s] Infiltration [m3/s] Total Ventilation and Infiltration [m3/s] Dynamic Target Ventilation - Voz-dyn [m3/s] Time Below Voz-dyn [hr] Time At Voz-dyn [hr] Time Above Voz-dyn [hr]
BASEMENT 1.9704 0.0000 1.9704 0.0000 1.9704 0.9949 1369.07 1716.22 2857.70
CORE_BOTTOM 1.4928 0.0000 1.4928 0.0000 1.4928 1.0778 2869.58 223.70 2849.73
CORE_MID 11.9345 0.0000 11.9345 0.0000 11.9345 10.7782 3010.98 633.40 2298.62
CORE_TOP 1.1330 0.0000 1.1330 0.0000 1.1330 1.0778 3262.00 597.18 2083.82
PERIMETER_BOT_ZN_3 0.1731 0.0000 0.1731 0.0025 0.1756 0.1353 2030.25 262.57 3650.18
PERIMETER_BOT_ZN_2 0.1431 0.0000 0.1431 0.0017 0.1448 0.0872 1516.99 56.24 4369.77
PERIMETER_BOT_ZN_1 0.2359 0.0000 0.2359 0.0025 0.2384 0.1353 1867.96 224.95 3850.09
PERIMETER_BOT_ZN_4 0.2263 0.0000 0.2263 0.0017 0.2280 0.0872 1286.22 0.76 4656.02
PERIMETER_MID_ZN_3 1.5308 0.0000 1.5308 0.0060 1.5368 1.3533 1860.37 649.49 3433.13
PERIMETER_MID_ZN_2 1.2838 0.0000 1.2838 0.0042 1.2880 0.8721 1405.59 6.35 3622.06
PERIMETER_MID_ZN_1 2.1571 0.0000 2.1571 0.0060 2.1630 1.3533 1652.46 630.69 3659.84
PERIMETER_MID_ZN_4 1.4841 0.0000 1.4841 0.0040 1.4881 0.8721 1389.14 3.27 4550.59
PERIMETER_TOP_ZN_3 0.1531 0.0000 0.1531 0.0074 0.1605 0.1353 1981.78 603.72 3357.51
PERIMETER_TOP_ZN_2 0.1400 0.0000 0.1400 0.0049 0.1449 0.0872 1452.05 7.17 4483.78
PERIMETER_TOP_ZN_1 0.2031 0.0000 0.2031 0.0074 0.2105 0.1353 1804.58 664.32 3474.11
PERIMETER_TOP_ZN_4 0.1493 0.0000 0.1493 0.0049 0.1542 0.0872 1432.43 2.29 4508.28
DATACENTER_BOT_ZN_6 0.0114 0.0000 0.0114 0.0000 0.0114 0.0130 1602.00 504.00 3837.00
DATACENTER_MID_ZN_6 0.1142 0.0000 0.1142 0.0000 0.1142 0.1296 1602.00 504.00 3837.00
DATACENTER_TOP_ZN_6 0.0114 0.0000 0.0114 0.0000 0.0114 0.0130 1602.00 504.00 3837.00
DATACENTER_BASEMENT_ZN_6 0.0000 0.0000 0.0000 0.0000 0.0000 0.2805 5943.00 0.00 0.00
Total Facility 191.0875 0.0000 191.0875 0.2346 191.3220 157.9346 5943.00 2720.60 4718.56


Total Outdoor Air by AirLoop

Mechanical Ventilation [m3] Natural Ventilation [m3/s] Total Ventilation [m3/s] Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] Time Below Voz-sum-dyn [hr] Time At Voz-sum-dyn [hr] Time Above Voz-sum-dyn [hr] Time Above Zero When Unoccupied [hr]
VAV_BOT WITH REHEAT 69140792.42 0.00 69140792.42 48026705.38 3808.33 2.07 4949.60 303.14
VAV_MID WITH REHEAT 0.54E+09 0.00 0.54E+09 0.48E+09 4136.62 3.86 4619.52 94.62
VAV_TOP WITH REHEAT 52003237.70 0.00 52003237.70 48026705.38 4211.36 3.01 4545.64 180.20
CAV_BAS 59907986.72 0.00 59907986.72 29876159.83 3936.41 1.74 4821.85 295.77
AIRLOOP DATACENTER BOT 329287.87 0.00 329287.87 389144.62 4419.00 0.00 4341.00 0.00
AIRLOOP DATACENTER MID 3292878.72 0.00 3292878.72 3891446.16 4419.00 0.00 4341.00 0.00
AIRLOOP DATACENTER TOP 329287.87 0.00 329287.87 389144.62 4419.00 0.00 4341.00 0.00


Average Outdoor Air During Occupancy by AirLoop

Mechanical Ventilation [m3/s] Natural Ventilation [m3/s] Total Ventilation [m3/s] Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] Time Below Voz-sum-dyn [hr] Time At Voz-sum-dyn [hr] Time Above Voz-sum-dyn [hr]
VAV_BOT WITH REHEAT 3.0607 0.0000 3.0607 1.5229 1287.72 1.88 4653.39
VAV_MID WITH REHEAT 24.9503 0.0000 24.9503 15.2292 1376.69 3.51 4562.81
VAV_TOP WITH REHEAT 2.3966 0.0000 2.3966 1.5229 1432.38 1.96 4508.66
CAV_BAS 2.6558 0.0000 2.6558 0.9949 1362.35 0.12 4580.52
AIRLOOP DATACENTER BOT 0.0154 0.0000 0.0154 0.0130 1602.00 0.00 4341.00
AIRLOOP DATACENTER MID 0.1539 0.0000 0.1539 0.1296 1602.00 0.00 4341.00
AIRLOOP DATACENTER TOP 0.0154 0.0000 0.0154 0.0130 1602.00 0.00 4341.00


Outdoor Air Controller Limiting Factors by AirLoop

No Limiting Factor [hr] Limits and Scheduled Limits [hr] Economizer [hr] Exhaust Flow [hr] Mixed Air Flow [hr] High Humidity [hr] Demand Controlled Ventilation [hr] Night Ventilation [hr] Demand Limiting [hr] Energy Management System [hr]
VAV_BOT WITH REHEAT 0.00 1.29 2980.47 0.00 0.00 0.00 2004.53 0.00 0.00 0.00
VAV_MID WITH REHEAT 0.00 0.37 2537.32 0.00 0.00 0.00 2178.14 0.00 0.00 0.00
VAV_TOP WITH REHEAT 0.00 0.71 2402.69 0.00 0.00 0.00 2397.32 0.00 0.00 0.00
CAV_BAS 0.00 0.00 3174.69 0.00 0.00 0.00 1711.86 0.00 0.00 0.00
AIRLOOP DATACENTER BOT 0.00 4341.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
AIRLOOP DATACENTER MID 0.00 4341.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
AIRLOOP DATACENTER TOP 0.00 4341.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Average Outdoor Air for Limiting Factors During Occupancy

No Limiting Factor [m3/s] Limits and Scheduled Limits [m3/s] Economizer [m3/s] Exhaust Flow [m3/s] Mixed Air Flow [m3/s] High Humidity [m3/s] Demand Controlled Ventilation [m3/s] Night Ventilation [m3/s] Demand Limiting [m3/s] Energy Management System [m3/s]
VAV_BOT WITH REHEAT 0.0000 14.6067 5.1329 0.0000 0.0000 0.0000 2.2126 0.0000 0.0000 0.0000
VAV_MID WITH REHEAT 0.0000 0.0000 41.0093 0.0000 0.0000 0.0000 22.0824 0.0000 0.0000 0.0000
VAV_TOP WITH REHEAT 0.0000 0.0000 4.0601 0.0000 0.0000 0.0000 2.1748 0.0000 0.0000 0.0000
CAV_BAS 0.0000 0.0000 4.6548 0.0000 0.0000 0.0000 1.3951 0.0000 0.0000 0.0000
AIRLOOP DATACENTER BOT 0.0000 0.0211 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
AIRLOOP DATACENTER MID 0.0000 0.2108 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
AIRLOOP DATACENTER TOP 0.0000 0.0211 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000



Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Surfaces by Class

Total Outdoors
Wall 98 30
Floor 41 0
Roof 30 1
Internal Mass 16 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 24 24
Door 12 12
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 7
Conditioned Zones 23
Unconditioned Zones 0
Supply Plenums 0
Return Plenums 3


Input Fields

Count
IDF Objects 1358
Defaulted Fields 1168
Fields with Defaults 3880
Autosized Fields 316
Autosizable Fields 394
Autocalculated Fields 226
Autocalculatable Fields 473



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Electricity Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
Electricity:Facility 24195.80 284399.12 08-JAN-04:00 1652636.69 12-APR-15:20
Electricity:Building 16705.72 216770.18 29-MAY-17:10 973173.63 06-DEC-08:10
Electricity:Zone:BASEMENT 559.97 14115.26 01-JAN-00:10 25295.37 02-JAN-08:10
Electricity:SpaceType:GENERAL 16705.72 216770.18 29-MAY-17:10 973173.63 06-DEC-08:10
InteriorLights:Electricity 2029.32 9514.02 01-JAN-11:30 198743.45 30-OCT-07:10
InteriorLights:Electricity:Zone:BASEMENT 135.58 657.72 01-JAN-00:10 11837.83 02-JAN-08:10
InteriorLights:Electricity:SpaceType:GENERAL 2029.32 9514.02 01-JAN-11:30 198743.45 30-OCT-07:10
LightsWired:InteriorLights:Electricity 2029.32 9514.02 01-JAN-11:30 198743.45 30-OCT-07:10
LightsWired:InteriorLights:Electricity:Zone:BASEMENT 135.58 657.72 01-JAN-00:10 11837.83 02-JAN-08:10
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL 2029.32 9514.02 01-JAN-11:30 198743.45 30-OCT-07:10
Electricity:Zone:CORE_BOTTOM 411.37 5043.91 01-JAN-00:10 27837.83 02-JAN-08:10
InteriorLights:Electricity:Zone:CORE_BOTTOM 121.76 590.68 01-JAN-00:10 10631.20 02-JAN-08:10
LightsWired:InteriorLights:Electricity:Zone:CORE_BOTTOM 121.76 590.68 01-JAN-00:10 10631.20 02-JAN-08:10
Electricity:Zone:CORE_MID 4113.71 50438.97 01-JAN-00:10 278377.67 02-JAN-08:10
InteriorLights:Electricity:Zone:CORE_MID 1217.58 5906.80 01-JAN-00:10 106312.04 02-JAN-08:10
LightsWired:InteriorLights:Electricity:Zone:CORE_MID 1217.58 5906.80 01-JAN-00:10 106312.04 02-JAN-08:10
Electricity:Zone:CORE_TOP 411.37 5043.90 01-JAN-00:10 27837.77 02-JAN-08:10
InteriorLights:Electricity:Zone:CORE_TOP 121.76 590.68 01-JAN-00:10 10631.20 02-JAN-08:10
LightsWired:InteriorLights:Electricity:Zone:CORE_TOP 121.76 590.68 01-JAN-00:10 10631.20 02-JAN-08:10
Electricity:Zone:PERIMETER_BOT_ZN_3 45.51 594.46 16-APR-17:10 3492.62 30-OCT-07:10
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_3 9.15 35.29 01-JAN-11:30 1332.07 30-OCT-07:10
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_3 9.15 35.29 01-JAN-11:30 1332.07 30-OCT-07:10
Electricity:Zone:PERIMETER_BOT_ZN_2 29.21 383.09 29-MAY-17:10 2250.78 30-OCT-07:10
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_2 5.77 22.74 01-JAN-09:20 858.43 30-OCT-07:10
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_2 5.77 22.74 01-JAN-09:20 858.43 30-OCT-07:10
Electricity:Zone:PERIMETER_BOT_ZN_1 45.21 594.47 12-MAR-17:10 3492.68 30-OCT-07:10
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_1 8.85 35.29 01-JAN-09:20 1332.10 30-OCT-07:10
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_1 8.85 35.29 01-JAN-09:20 1332.10 30-OCT-07:10
Electricity:Zone:PERIMETER_BOT_ZN_4 29.27 383.09 05-MAR-18:10 2250.77 30-OCT-07:10
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_4 5.83 22.74 01-JAN-11:10 858.43 30-OCT-07:10
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_4 5.83 22.74 01-JAN-11:10 858.43 30-OCT-07:10
Electricity:Zone:PERIMETER_MID_ZN_3 455.12 5944.59 16-APR-17:10 34926.80 30-OCT-07:10
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_3 91.47 352.88 01-JAN-11:30 13321.29 30-OCT-07:10
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_3 91.47 352.88 01-JAN-11:30 13321.29 30-OCT-07:10
Electricity:Zone:PERIMETER_MID_ZN_2 292.08 3830.92 21-MAY-17:10 22507.79 30-OCT-07:10
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_2 57.72 227.41 01-JAN-09:20 8584.37 30-OCT-07:10
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_2 57.72 227.41 01-JAN-09:20 8584.37 30-OCT-07:10
Electricity:Zone:PERIMETER_MID_ZN_1 452.21 5944.68 12-MAR-17:10 34927.43 30-OCT-07:10
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_1 88.55 352.89 01-JAN-09:20 13321.58 30-OCT-07:10
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_1 88.55 352.89 01-JAN-09:20 13321.58 30-OCT-07:10
Electricity:Zone:PERIMETER_MID_ZN_4 292.65 3830.90 12-MAR-17:10 22507.70 30-OCT-07:10
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_4 58.30 227.41 01-JAN-11:10 8584.37 30-OCT-07:10
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_4 58.30 227.41 01-JAN-11:10 8584.37 30-OCT-07:10
Electricity:Zone:PERIMETER_TOP_ZN_3 45.51 594.46 16-APR-17:10 3492.68 30-OCT-07:10
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_3 9.15 35.29 01-JAN-11:30 1332.13 30-OCT-07:10
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_3 9.15 35.29 01-JAN-11:30 1332.13 30-OCT-07:10
Electricity:Zone:PERIMETER_TOP_ZN_2 29.21 383.09 21-MAY-17:10 2250.78 30-OCT-07:10
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_2 5.77 22.74 01-JAN-09:20 858.44 30-OCT-07:10
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_2 5.77 22.74 01-JAN-09:20 858.44 30-OCT-07:10
Electricity:Zone:PERIMETER_TOP_ZN_1 45.22 594.47 12-MAR-17:10 3492.74 30-OCT-07:10
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_1 8.86 35.29 01-JAN-09:20 1332.15 30-OCT-07:10
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_1 8.86 35.29 01-JAN-09:20 1332.15 30-OCT-07:10
Electricity:Zone:PERIMETER_TOP_ZN_4 29.27 383.09 12-MAR-17:10 2250.77 30-OCT-07:10
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_4 5.83 22.74 01-JAN-11:10 858.44 30-OCT-07:10
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_4 5.83 22.74 01-JAN-11:10 858.44 30-OCT-07:10
Electricity:Zone:DATACENTER_BASEMENT_ZN_6 7533.08 95093.58 01-JAN-00:10 382970.28 03-APR-07:10
InteriorLights:Electricity:Zone:DATACENTER_BASEMENT_ZN_6 38.23 185.45 01-JAN-00:10 3337.76 02-JAN-08:10
LightsWired:InteriorLights:Electricity:Zone:DATACENTER_BASEMENT_ZN_6 38.23 185.45 01-JAN-00:10 3337.76 02-JAN-08:10
Electricity:Zone:DATACENTER_BOT_ZN_6 157.14 1964.44 01-JAN-00:10 8079.39 03-APR-07:10
InteriorLights:Electricity:Zone:DATACENTER_BOT_ZN_6 3.26 15.83 01-JAN-00:10 284.97 02-JAN-08:10
LightsWired:InteriorLights:Electricity:Zone:DATACENTER_BOT_ZN_6 3.26 15.83 01-JAN-00:10 284.97 02-JAN-08:10
Electricity:Zone:DATACENTER_MID_ZN_6 1571.44 19644.38 01-JAN-00:10 80793.90 03-APR-07:10
InteriorLights:Electricity:Zone:DATACENTER_MID_ZN_6 32.64 158.32 01-JAN-00:10 2849.68 02-JAN-08:10
LightsWired:InteriorLights:Electricity:Zone:DATACENTER_MID_ZN_6 32.64 158.32 01-JAN-00:10 2849.68 02-JAN-08:10
Electricity:Zone:DATACENTER_TOP_ZN_6 157.14 1964.44 01-JAN-00:10 8079.39 03-APR-07:10
InteriorLights:Electricity:Zone:DATACENTER_TOP_ZN_6 3.26 15.83 01-JAN-00:10 284.97 02-JAN-08:10
LightsWired:InteriorLights:Electricity:Zone:DATACENTER_TOP_ZN_6 3.26 15.83 01-JAN-00:10 284.97 02-JAN-08:10
InteriorEquipment:Electricity 14676.40 207256.16 01-JAN-00:10 778371.69 03-APR-07:10
InteriorEquipment:Electricity:Zone:BASEMENT 424.40 13457.54 01-JAN-00:10 13457.54 01-JAN-00:10
InteriorEquipment:Electricity:SpaceType:GENERAL 14676.40 207256.16 01-JAN-00:10 778371.69 03-APR-07:10
MiscPlug:InteriorEquipment:Electricity 5334.97 88964.76 01-JAN-00:10 305206.10 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:BASEMENT 424.40 13457.54 01-JAN-00:10 13457.54 01-JAN-00:10
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL 5334.97 88964.76 01-JAN-00:10 305206.10 02-JAN-08:10
InteriorEquipment:Electricity:Zone:CORE_BOTTOM 289.61 4453.23 01-JAN-00:10 17206.63 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_BOTTOM 289.61 4453.23 01-JAN-00:10 17206.63 02-JAN-08:10
InteriorEquipment:Electricity:Zone:CORE_MID 2896.13 44532.17 01-JAN-00:10 172065.63 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_MID 2896.13 44532.17 01-JAN-00:10 172065.63 02-JAN-08:10
InteriorEquipment:Electricity:Zone:CORE_TOP 289.61 4453.22 01-JAN-00:10 17206.56 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_TOP 289.61 4453.22 01-JAN-00:10 17206.56 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_3 36.37 559.17 01-JAN-00:10 2160.55 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_3 36.37 559.17 01-JAN-00:10 2160.55 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_2 23.44 360.35 01-JAN-00:10 1392.34 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_2 23.44 360.35 01-JAN-00:10 1392.34 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_1 36.37 559.18 01-JAN-00:10 2160.58 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_1 36.37 559.18 01-JAN-00:10 2160.58 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_4 23.44 360.35 01-JAN-00:10 1392.33 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_4 23.44 360.35 01-JAN-00:10 1392.33 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_3 363.65 5591.71 01-JAN-00:10 21605.52 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_3 363.65 5591.71 01-JAN-00:10 21605.52 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_2 234.35 3603.51 01-JAN-00:10 13923.42 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_2 234.35 3603.51 01-JAN-00:10 13923.42 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_1 363.66 5591.79 01-JAN-00:10 21605.85 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_1 363.66 5591.79 01-JAN-00:10 21605.85 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_4 234.35 3603.49 01-JAN-00:10 13923.33 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_4 234.35 3603.49 01-JAN-00:10 13923.33 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_3 36.37 559.17 01-JAN-00:10 2160.55 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_3 36.37 559.17 01-JAN-00:10 2160.55 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_2 23.44 360.35 01-JAN-00:10 1392.34 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_2 23.44 360.35 01-JAN-00:10 1392.34 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_1 36.37 559.18 01-JAN-00:10 2160.58 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_1 36.37 559.18 01-JAN-00:10 2160.58 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_4 23.44 360.35 01-JAN-00:10 1392.33 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_4 23.44 360.35 01-JAN-00:10 1392.33 02-JAN-08:10
InteriorEquipment:Electricity:Zone:DATACENTER_BASEMENT_ZN_6 7494.86 94908.13 01-JAN-00:10 379632.52 31-MAR-23:10
DataCenterPlugLoads:InteriorEquipment:Electricity 9341.42 118291.40 01-JAN-00:10 473165.59 31-MAR-23:10
DataCenterPlugLoads:InteriorEquipment:Electricity:Zone:DATACENTER_BASEMENT_ZN_6 7494.86 94908.13 01-JAN-00:10 379632.52 31-MAR-23:10
DataCenterPlugLoads:InteriorEquipment:Electricity:SpaceType:GENERAL 9341.42 118291.40 01-JAN-00:10 473165.59 31-MAR-23:10
InteriorEquipment:Electricity:Zone:DATACENTER_BOT_ZN_6 153.88 1948.61 01-JAN-00:10 7794.42 31-MAR-23:10
DataCenterPlugLoads:InteriorEquipment:Electricity:Zone:DATACENTER_BOT_ZN_6 153.88 1948.61 01-JAN-00:10 7794.42 31-MAR-23:10
InteriorEquipment:Electricity:Zone:DATACENTER_MID_ZN_6 1538.81 19486.06 01-JAN-00:10 77944.22 31-MAR-23:10
DataCenterPlugLoads:InteriorEquipment:Electricity:Zone:DATACENTER_MID_ZN_6 1538.81 19486.06 01-JAN-00:10 77944.22 31-MAR-23:10
InteriorEquipment:Electricity:Zone:DATACENTER_TOP_ZN_6 153.88 1948.61 01-JAN-00:10 7794.42 31-MAR-23:10
DataCenterPlugLoads:InteriorEquipment:Electricity:Zone:DATACENTER_TOP_ZN_6 153.88 1948.61 01-JAN-00:10 7794.42 31-MAR-23:10
Electricity:Plant 2302.54 697.09 08-JAN-04:40 364530.09 15-MAY-16:00
HeatRejection:Electricity 475.90 21.87 07-JAN-18:00 52437.43 30-MAR-13:10
General:HeatRejection:Electricity 475.90 21.87 07-JAN-18:00 52437.43 30-MAR-13:10
Electricity:HVAC 1655.88 7309.11 08-JAN-06:00 244227.45 15-MAY-16:00
ExteriorEquipment:Electricity 3258.17 45245.36 01-JAN-00:10 185197.08 06-DEC-08:20
Transformer:ExteriorEquipment:Electricity 54.48 979.82 01-JAN-00:10 3387.33 30-OCT-07:20
ElectricityPurchased:Facility 24195.80 284399.12 08-JAN-04:00 1652636.69 12-APR-15:20
ElectricityPurchased:Plant 24195.80 284399.12 08-JAN-04:00 1652636.69 12-APR-15:20
Cogeneration:ElectricityPurchased 24195.80 284399.12 08-JAN-04:00 1652636.69 12-APR-15:20
General:Cogeneration:ElectricityPurchased 24195.80 284399.12 08-JAN-04:00 1652636.69 12-APR-15:20
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricityNet:Facility 24195.80 284399.12 08-JAN-04:00 1652636.69 12-APR-15:20
ElectricityNet:Plant 24195.80 284399.12 08-JAN-04:00 1652636.69 12-APR-15:20
Cogeneration:ElectricityNet 24195.80 284399.12 08-JAN-04:00 1652636.69 12-APR-15:20
General:Cogeneration:ElectricityNet 24195.80 284399.12 08-JAN-04:00 1652636.69 12-APR-15:20
Fans:Electricity 1159.91 6088.60 01-JAN-01:00 232032.16 15-MAY-16:00
General:Fans:Electricity 1159.91 6088.60 01-JAN-01:00 232032.16 15-MAY-16:00
ExteriorLights:Electricity 327.97 0.00 01-JAN-07:50 37611.08 01-JAN-06:10
General:ExteriorLights:Electricity 327.97 0.00 01-JAN-07:50 37611.08 01-JAN-06:10
ComputerHVAC:ExteriorEquipment:Electricity 1349.07 17083.47 01-JAN-00:10 68333.87 31-MAR-23:10
ElevatorLift:ExteriorEquipment:Electricity 1848.78 27144.47 01-JAN-00:10 113101.96 01-JAN-07:10
ElevatorLightsFan:ExteriorEquipment:Electricity 5.83 37.60 01-JAN-00:10 376.00 01-JAN-07:10
HeatRecovery:Electricity 45.36 0.00 01-JAN-00:10 5613.48 02-JAN-07:10
General:HeatRecovery:Electricity 45.36 0.00 01-JAN-00:10 5613.48 02-JAN-07:10
Cooling:Electricity 1574.96 109.44 09-JAN-07:10 261918.69 02-AUG-12:10
General:Cooling:Electricity 1574.96 109.44 09-JAN-07:10 261918.69 02-AUG-12:10
Heating:Electricity 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Heating:Electricity 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Boiler Parasitic:Heating:Electricity 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Pumps:Electricity 647.80 664.31 17-JAN-04:30 62594.34 15-MAY-16:00
General:Pumps:Electricity 647.80 664.31 17-JAN-04:30 62594.34 15-MAY-16:00
WIRED_LTG_ELECTRICITY 57.02 0.00 01-JAN-00:10 5584.69 30-OCT-07:20
WIRED_INT_EQUIP 5334.97 88964.76 31-MAR-23:10 305206.10 03-APR-07:10


Annual and Peak Values - Natural Gas

Natural Gas Annual Value [GJ] Natural Gas Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Natural Gas Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
NaturalGas:Facility 1032.81 5695.87 01-JAN-00:10 1108500.87 09-JAN-07:10
NaturalGas:Plant 1032.81 5695.87 01-JAN-00:10 1108500.87 09-JAN-07:10
Heating:NaturalGas 375.10 0.00 01-JAN-00:10 1079376.27 09-JAN-07:10
Boiler:Heating:NaturalGas 375.10 0.00 01-JAN-00:10 1079376.27 09-JAN-07:10
WaterSystems:NaturalGas 657.70 5695.87 09-JAN-04:10 79713.29 02-FEB-13:00
Water Heater:WaterSystems:NaturalGas 657.70 5695.87 09-JAN-04:10 79713.29 02-FEB-13:00


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Cooling Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
PlantLoopCoolingDemand:Facility 10093.21 473.20 09-JAN-07:10 1731322.24 25-AUG-14:00
PlantLoopCoolingDemand:HVAC 10093.21 473.20 09-JAN-07:10 1731322.24 25-AUG-14:00
CoolingCoils:PlantLoopCoolingDemand 10093.21 473.20 09-JAN-07:10 1731322.24 25-AUG-14:00
DistrictCooling:Facility 7163.44 85039.05 09-JAN-05:00 369582.79 07-AUG-14:00
DistrictCooling:HVAC 7163.44 85039.05 09-JAN-05:00 369582.79 07-AUG-14:00
Cooling:DistrictCooling 7163.44 85039.05 09-JAN-05:00 369582.79 07-AUG-14:00
General:Cooling:DistrictCooling 7163.44 85039.05 09-JAN-05:00 369582.79 07-AUG-14:00


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [m3/s] Timestamp of Maximum {TIMESTAMP}
Water:Facility 8955.68 0.00 01-JAN-00:10 0.00 14-APR-12:40
Water:Plant 8955.68 0.00 01-JAN-00:10 0.00 14-APR-12:40
WaterSystems:Water 2280.17 0.00 01-JAN-00:10 0.00 02-JAN-12:10
WaterUse:WaterSystems:Water 2280.17 0.00 01-JAN-00:10 0.00 02-JAN-12:10
MainsWater:Facility 8955.68 0.00 01-JAN-00:10 0.00 14-APR-12:40
MainsWater:Plant 8955.68 0.00 01-JAN-00:10 0.00 14-APR-12:40
WaterSystems:MainsWater 2280.17 0.00 01-JAN-00:10 0.00 02-JAN-12:10
WaterUse:WaterSystems:MainsWater 2280.17 0.00 01-JAN-00:10 0.00 02-JAN-12:10
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
HeatRejection:Water 6675.52 0.00 01-JAN-00:10 0.00 17-APR-14:10
General:HeatRejection:Water 6675.52 0.00 01-JAN-00:10 0.00 17-APR-14:10
HeatRejection:MainsWater 6675.52 0.00 01-JAN-00:10 0.00 17-APR-14:10
General:HeatRejection:MainsWater 6675.52 0.00 01-JAN-00:10 0.00 17-APR-14:10


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [kg/s] Timestamp of Maximum {TIMESTAMP}
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:10 0.000 01-JAN-00:10
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:10 0.000 01-JAN-00:10


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [m3/s] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum {TIMESTAMP} Maximum Value [L] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
EnergyTransfer:Facility 54623.07 91980.32 09-JAN-04:40 8442034.73 15-MAY-16:00
EnergyTransfer:Building 18030.78 87730.38 14-JAN-19:50 1465579.91 02-AUG-15:40
EnergyTransfer:Zone:BASEMENT 593.08 0.00 01-JAN-00:10 71386.80 13-NOV-06:20
Heating:EnergyTransfer 206.77 0.00 19-JAN-19:20 631681.98 09-JAN-06:10
Heating:EnergyTransfer:Zone:BASEMENT 4.82 0.00 01-JAN-00:10 17878.35 08-JUL-16:10
General:Heating:EnergyTransfer 206.77 0.00 19-JAN-19:20 631681.98 09-JAN-06:10
General:Heating:EnergyTransfer:Zone:BASEMENT 4.82 0.00 01-JAN-00:10 17878.35 08-JUL-16:10
Cooling:EnergyTransfer 17824.00 85474.86 09-JAN-04:40 1465579.91 02-AUG-15:40
Cooling:EnergyTransfer:Zone:BASEMENT 588.27 0.00 01-JAN-00:10 71386.80 13-NOV-06:20
General:Cooling:EnergyTransfer 17824.00 85474.86 09-JAN-04:40 1465579.91 02-AUG-15:40
General:Cooling:EnergyTransfer:Zone:BASEMENT 588.27 0.00 01-JAN-00:10 71386.80 13-NOV-06:20
EnergyTransfer:Zone:CORE_BOTTOM 595.79 0.00 01-JAN-00:10 48482.29 07-AUG-09:20
Heating:EnergyTransfer:Zone:CORE_BOTTOM 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Heating:EnergyTransfer:Zone:CORE_BOTTOM 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cooling:EnergyTransfer:Zone:CORE_BOTTOM 595.79 0.00 01-JAN-00:10 48482.29 07-AUG-09:20
General:Cooling:EnergyTransfer:Zone:CORE_BOTTOM 595.79 0.00 01-JAN-00:10 48482.29 07-AUG-09:20
EnergyTransfer:Zone:CORE_MID 4229.45 0.00 01-JAN-00:10 418584.15 16-MAY-14:00
Heating:EnergyTransfer:Zone:CORE_MID 0.27 0.00 01-JAN-00:10 112100.68 09-JAN-06:10
General:Heating:EnergyTransfer:Zone:CORE_MID 0.27 0.00 01-JAN-00:10 112100.68 09-JAN-06:10
Cooling:EnergyTransfer:Zone:CORE_MID 4229.18 0.00 01-JAN-00:10 418584.15 16-MAY-14:00
General:Cooling:EnergyTransfer:Zone:CORE_MID 4229.18 0.00 01-JAN-00:10 418584.15 16-MAY-14:00
EnergyTransfer:Zone:CORE_TOP 405.83 0.00 01-JAN-00:10 62398.78 09-JAN-05:10
Heating:EnergyTransfer:Zone:CORE_TOP 7.06 0.00 01-JAN-00:10 62398.78 09-JAN-05:10
General:Heating:EnergyTransfer:Zone:CORE_TOP 7.06 0.00 01-JAN-00:10 62398.78 09-JAN-05:10
Cooling:EnergyTransfer:Zone:CORE_TOP 398.77 0.00 01-JAN-00:10 47343.25 18-MAY-14:40
General:Cooling:EnergyTransfer:Zone:CORE_TOP 398.77 0.00 01-JAN-00:10 47343.25 18-MAY-14:40
EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 74.05 0.00 01-JAN-00:10 9244.08 09-AUG-14:40
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 0.13 0.00 01-JAN-00:10 3931.11 13-FEB-06:10
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 0.13 0.00 01-JAN-00:10 3931.11 13-FEB-06:10
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 73.92 0.00 01-JAN-00:10 9244.08 09-AUG-14:40
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 73.92 0.00 01-JAN-00:10 9244.08 09-AUG-14:40
EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 59.53 0.00 01-JAN-00:10 10091.33 07-JUL-09:20
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 0.10 0.00 01-JAN-00:10 2761.17 13-FEB-06:10
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 0.10 0.00 01-JAN-00:10 2761.17 13-FEB-06:10
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 59.43 0.00 01-JAN-00:10 10091.33 07-JUL-09:20
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 59.43 0.00 01-JAN-00:10 10091.33 07-JUL-09:20
EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 94.17 0.00 01-JAN-00:10 14017.31 10-OCT-13:40
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 0.19 0.00 01-JAN-00:10 6130.60 09-JAN-06:10
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 0.19 0.00 01-JAN-00:10 6130.60 09-JAN-06:10
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 93.99 0.00 01-JAN-00:10 14017.31 10-OCT-13:40
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 93.99 0.00 01-JAN-00:10 14017.31 10-OCT-13:40
EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 95.01 0.00 01-JAN-00:10 13356.36 02-AUG-16:00
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 0.00 0.00 01-JAN-00:10 1535.36 09-JAN-06:10
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 0.00 0.00 01-JAN-00:10 1535.36 09-JAN-06:10
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 95.01 0.00 01-JAN-00:10 13356.36 02-AUG-16:00
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 95.01 0.00 01-JAN-00:10 13356.36 02-AUG-16:00
EnergyTransfer:Zone:PERIMETER_MID_ZN_3 563.85 0.00 01-JAN-00:10 100508.15 13-FEB-05:10
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 38.11 0.00 01-JAN-00:10 100508.15 13-FEB-05:10
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 38.11 0.00 01-JAN-00:10 100508.15 13-FEB-05:10
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 525.73 0.00 01-JAN-00:10 84803.57 14-JUL-15:00
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 525.73 0.00 01-JAN-00:10 84803.57 14-JUL-15:00
EnergyTransfer:Zone:PERIMETER_MID_ZN_2 514.57 0.00 01-JAN-00:10 104780.01 07-JUL-09:00
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 18.33 0.00 01-JAN-00:10 82827.31 09-JAN-06:20
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 18.33 0.00 01-JAN-00:10 82827.31 09-JAN-06:20
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 496.24 0.00 01-JAN-00:10 104780.01 07-JUL-09:00
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 496.24 0.00 01-JAN-00:10 104780.01 07-JUL-09:00
EnergyTransfer:Zone:PERIMETER_MID_ZN_1 775.22 0.00 01-JAN-00:10 132367.02 10-OCT-13:40
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 14.08 0.00 01-JAN-00:10 108040.52 09-JAN-06:20
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 14.08 0.00 01-JAN-00:10 108040.52 09-JAN-06:20
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 761.14 0.00 01-JAN-00:10 132367.02 10-OCT-13:40
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 761.14 0.00 01-JAN-00:10 132367.02 10-OCT-13:40
EnergyTransfer:Zone:PERIMETER_MID_ZN_4 545.51 0.00 01-JAN-00:10 106002.42 02-AUG-16:00
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 12.13 0.00 01-JAN-00:10 70493.17 09-JAN-06:20
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 12.13 0.00 01-JAN-00:10 70493.17 09-JAN-06:20
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 533.37 0.00 01-JAN-00:10 106002.42 02-AUG-16:00
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 533.37 0.00 01-JAN-00:10 106002.42 02-AUG-16:00
EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 65.06 0.00 01-JAN-00:10 12829.41 13-FEB-04:10
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 13.77 0.00 01-JAN-00:10 12829.41 13-FEB-04:10
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 13.77 0.00 01-JAN-00:10 12829.41 13-FEB-04:10
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 51.29 0.00 01-JAN-00:10 9654.50 14-JUL-15:00
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 51.29 0.00 01-JAN-00:10 9654.50 14-JUL-15:00
EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 56.00 0.00 01-JAN-00:10 11380.09 09-JAN-05:10
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 6.61 0.00 01-JAN-00:10 11380.09 09-JAN-05:10
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 6.61 0.00 01-JAN-00:10 11380.09 09-JAN-05:10
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 49.39 0.00 01-JAN-00:10 10927.90 07-JUL-09:40
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 49.39 0.00 01-JAN-00:10 10927.90 07-JUL-09:40
EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 78.95 0.00 01-JAN-00:10 14502.86 10-OCT-13:50
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 6.54 0.00 01-JAN-00:10 13502.16 09-JAN-05:10
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 6.54 0.00 01-JAN-00:10 13502.16 09-JAN-05:10
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 72.41 0.00 01-JAN-00:10 14502.86 10-OCT-13:50
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 72.41 0.00 01-JAN-00:10 14502.86 10-OCT-13:50
EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 58.01 0.00 01-JAN-00:10 11674.63 09-JAN-06:20
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 4.99 0.00 01-JAN-00:10 11674.63 09-JAN-06:20
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 4.99 0.00 01-JAN-00:10 11674.63 09-JAN-06:20
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 53.02 0.00 01-JAN-00:10 11447.77 02-AUG-16:00
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 53.02 0.00 01-JAN-00:10 11447.77 02-AUG-16:00
EnergyTransfer:Zone:GROUNDFLOOR_PLENUM 62.69 0.00 01-JAN-00:10 9141.71 07-AUG-07:10
Heating:EnergyTransfer:Zone:GROUNDFLOOR_PLENUM 1.78 0.00 01-JAN-00:10 3723.15 29-JAN-12:50
General:Heating:EnergyTransfer:Zone:GROUNDFLOOR_PLENUM 1.78 0.00 01-JAN-00:10 3723.15 29-JAN-12:50
Cooling:EnergyTransfer:Zone:GROUNDFLOOR_PLENUM 60.92 0.00 01-JAN-00:10 9141.71 07-AUG-07:10
General:Cooling:EnergyTransfer:Zone:GROUNDFLOOR_PLENUM 60.92 0.00 01-JAN-00:10 9141.71 07-AUG-07:10
EnergyTransfer:Zone:MIDFLOOR_PLENUM 453.55 0.00 01-JAN-00:10 64186.42 05-JUL-16:00
Heating:EnergyTransfer:Zone:MIDFLOOR_PLENUM 50.00 0.00 01-JAN-00:10 48676.95 10-JAN-15:00
General:Heating:EnergyTransfer:Zone:MIDFLOOR_PLENUM 50.00 0.00 01-JAN-00:10 48676.95 10-JAN-15:00
Cooling:EnergyTransfer:Zone:MIDFLOOR_PLENUM 403.55 0.00 01-JAN-00:10 64186.42 05-JUL-16:00
General:Cooling:EnergyTransfer:Zone:MIDFLOOR_PLENUM 403.55 0.00 01-JAN-00:10 64186.42 05-JUL-16:00
EnergyTransfer:Zone:TOPFLOOR_PLENUM 89.91 0.00 01-JAN-00:10 21454.61 13-FEB-05:30
Heating:EnergyTransfer:Zone:TOPFLOOR_PLENUM 24.84 0.00 01-JAN-00:10 21454.61 13-FEB-05:30
General:Heating:EnergyTransfer:Zone:TOPFLOOR_PLENUM 24.84 0.00 01-JAN-00:10 21454.61 13-FEB-05:30
Cooling:EnergyTransfer:Zone:TOPFLOOR_PLENUM 65.07 0.00 01-JAN-00:10 19506.40 07-JUL-15:10
General:Cooling:EnergyTransfer:Zone:TOPFLOOR_PLENUM 65.07 0.00 01-JAN-00:10 19506.40 07-JUL-15:10
EnergyTransfer:Zone:DATACENTER_BOT_ZN_6 138.13 359.00 09-JAN-06:30 7858.10 13-AUG-18:40
Heating:EnergyTransfer:Zone:DATACENTER_BOT_ZN_6 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Heating:EnergyTransfer:Zone:DATACENTER_BOT_ZN_6 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cooling:EnergyTransfer:Zone:DATACENTER_BOT_ZN_6 138.13 359.00 09-JAN-06:30 7858.10 13-AUG-18:40
General:Cooling:EnergyTransfer:Zone:DATACENTER_BOT_ZN_6 138.13 359.00 09-JAN-06:30 7858.10 13-AUG-18:40
EnergyTransfer:Zone:DATACENTER_MID_ZN_6 1227.49 2.93 05-JAN-07:20 73984.37 13-AUG-18:40
Heating:EnergyTransfer:Zone:DATACENTER_MID_ZN_6 2.29 0.00 02-JAN-09:30 5148.52 08-JAN-19:10
General:Heating:EnergyTransfer:Zone:DATACENTER_MID_ZN_6 2.29 0.00 02-JAN-09:30 5148.52 08-JAN-19:10
Cooling:EnergyTransfer:Zone:DATACENTER_MID_ZN_6 1225.20 0.00 01-JAN-00:10 73984.37 13-AUG-18:40
General:Cooling:EnergyTransfer:Zone:DATACENTER_MID_ZN_6 1225.20 0.00 01-JAN-00:10 73984.37 13-AUG-18:40
EnergyTransfer:Zone:DATACENTER_TOP_ZN_6 116.05 0.02 28-JAN-09:00 7647.39 13-AUG-19:10
Heating:EnergyTransfer:Zone:DATACENTER_TOP_ZN_6 0.72 0.00 02-JAN-14:50 565.76 22-JAN-18:50
General:Heating:EnergyTransfer:Zone:DATACENTER_TOP_ZN_6 0.72 0.00 02-JAN-14:50 565.76 22-JAN-18:50
Cooling:EnergyTransfer:Zone:DATACENTER_TOP_ZN_6 115.32 0.00 01-JAN-00:10 7647.39 13-AUG-19:10
General:Cooling:EnergyTransfer:Zone:DATACENTER_TOP_ZN_6 115.32 0.00 01-JAN-00:10 7647.39 13-AUG-19:10
EnergyTransfer:Zone:DATACENTER_BASEMENT_ZN_6 7138.86 85039.05 09-JAN-05:00 366909.35 07-AUG-16:00
Heating:EnergyTransfer:Zone:DATACENTER_BASEMENT_ZN_6 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Heating:EnergyTransfer:Zone:DATACENTER_BASEMENT_ZN_6 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cooling:EnergyTransfer:Zone:DATACENTER_BASEMENT_ZN_6 7138.86 85039.05 09-JAN-05:00 366909.35 07-AUG-16:00
General:Cooling:EnergyTransfer:Zone:DATACENTER_BASEMENT_ZN_6 7138.86 85039.05 09-JAN-05:00 366909.35 07-AUG-16:00
PlantLoopHeatingDemand:Facility 637.10 0.00 01-JAN-00:10 947425.08 09-JAN-07:10
PlantLoopHeatingDemand:Plant 371.93 0.00 01-JAN-00:10 47929.09 31-JAN-12:20
WaterSystems:PlantLoopHeatingDemand 371.93 0.00 01-JAN-00:10 47929.09 31-JAN-12:20
General:WaterSystems:PlantLoopHeatingDemand 371.93 0.00 01-JAN-00:10 47929.09 31-JAN-12:20
EnergyTransfer:HVAC 11177.12 892.99 08-JAN-06:00 1962452.00 10-AUG-16:00
HeatingCoils:EnergyTransfer 265.17 0.00 01-JAN-00:10 931698.48 09-JAN-07:10
PlantLoopHeatingDemand:HVAC 265.17 0.00 01-JAN-00:10 931698.48 09-JAN-07:10
HeatingCoils:PlantLoopHeatingDemand 265.17 0.00 01-JAN-00:10 931698.48 09-JAN-07:10
CoolingCoils:EnergyTransfer 9697.09 363.76 09-JAN-07:10 1703624.76 25-AUG-14:00
DistrictHeating:Facility 0.00 0.00 01-JAN-00:10 15.01 30-JUN-23:30
DistrictHeating:HVAC 0.00 0.00 01-JAN-00:10 15.01 30-JUN-23:30
Heating:DistrictHeating 0.00 0.00 01-JAN-00:10 15.01 30-JUN-23:30
General:Heating:DistrictHeating 0.00 0.00 01-JAN-00:10 15.01 30-JUN-23:30
HeatRecoveryForHeating:EnergyTransfer 402.59 0.00 01-JAN-00:10 472880.74 03-FEB-07:20
HeatRecoveryForCooling:EnergyTransfer 812.27 0.00 01-JAN-00:10 410580.08 08-JUL-14:00
EnergyTransfer:Plant 25415.18 0.00 01-JAN-00:10 5875253.83 15-MAY-16:00
LoopToLoop:EnergyTransfer 8476.79 -6242.88 19-JAN-06:10 1829859.74 15-MAY-16:00
WaterSystems:EnergyTransfer 371.93 0.00 01-JAN-00:10 47929.09 31-JAN-12:20
WaterUse:WaterSystems:EnergyTransfer 371.93 0.00 01-JAN-00:10 47929.09 31-JAN-12:20
Boilers:EnergyTransfer 262.63 0.00 01-JAN-00:10 902081.88 09-JAN-07:10
Chillers:EnergyTransfer 7562.50 0.00 01-JAN-00:10 1855755.14 15-MAY-16:00
HeatRejection:EnergyTransfer 8741.33 0.00 01-JAN-00:10 2105253.46 15-MAY-16:00
General:HeatRejection:EnergyTransfer 8741.33 0.00 01-JAN-00:10 2105253.46 15-MAY-16:00
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Annual Building Sensible Heat Gain Components

HVAC Zone Eq & Other Sensible Air Heating [GJ] HVAC Zone Eq & Other Sensible Air Cooling [GJ] HVAC Terminal Unit Sensible Air Heating [GJ] HVAC Terminal Unit Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
BASEMENT 0.000 0.000 4.817 -588.267 0.000 0.000 92.663 135.577 424.397 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 -69.188
CORE_BOTTOM 0.000 0.000 0.000 -595.792 0.000 0.000 83.475 121.758 289.614 0.000 0.000 0.000 100.946 0.000 0.000 0.000 0.000 -0.004
CORE_MID 0.000 0.000 0.270 -4229.162 0.000 0.000 846.005 1217.578 2896.128 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 -730.819
CORE_TOP 0.000 0.000 7.061 -398.763 0.000 0.000 87.089 121.758 289.613 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 -106.758
PERIMETER_BOT_ZN_3 0.000 0.000 0.130 -73.917 0.000 0.000 10.726 9.148 36.365 23.112 0.000 0.057 35.521 0.000 -39.877 0.000 -1.265 0.000
PERIMETER_BOT_ZN_2 0.000 0.000 0.097 -59.434 0.000 0.000 6.897 5.775 23.435 38.390 0.000 0.037 9.544 0.000 -23.903 0.000 -0.837 0.000
PERIMETER_BOT_ZN_1 0.000 0.000 0.186 -93.984 0.000 0.000 10.633 8.849 36.366 67.689 0.000 0.054 7.417 0.000 -35.923 0.000 -1.287 -0.001
PERIMETER_BOT_ZN_4 0.000 0.000 0.002 -95.011 0.000 0.000 6.802 5.834 23.435 37.727 0.000 0.033 51.092 0.000 -28.966 0.000 -0.950 0.000
PERIMETER_MID_ZN_3 0.000 0.000 38.111 -525.730 0.000 0.000 111.229 91.469 363.654 239.183 0.000 1.356 64.318 0.000 -357.345 0.000 -26.245 -0.012
PERIMETER_MID_ZN_2 0.000 0.000 18.335 -496.235 0.000 0.000 52.138 57.723 234.352 385.094 0.000 0.826 0.004 0.000 -223.039 0.000 -18.126 -11.069
PERIMETER_MID_ZN_1 0.000 0.000 14.085 -761.127 0.000 0.000 107.717 88.551 363.660 676.562 0.000 1.240 0.019 0.000 -346.469 0.000 -28.889 -115.330
PERIMETER_MID_ZN_4 0.000 0.000 12.132 -533.369 0.000 0.000 70.802 58.304 234.351 387.045 0.000 0.791 37.180 0.000 -248.259 0.000 -18.977 0.000
PERIMETER_TOP_ZN_3 0.000 0.000 13.771 -51.288 0.000 0.000 11.303 9.147 36.365 24.131 0.000 0.159 0.000 0.000 -33.263 0.000 -3.014 -7.311
PERIMETER_TOP_ZN_2 0.000 0.000 6.606 -49.393 0.000 0.000 7.183 5.772 23.435 38.753 0.000 0.098 0.000 0.000 -20.913 0.000 -2.091 -9.450
PERIMETER_TOP_ZN_1 0.000 0.000 6.542 -72.408 0.000 0.000 10.947 8.856 36.366 68.084 0.000 0.144 0.000 0.000 -32.508 0.000 -3.327 -22.697
PERIMETER_TOP_ZN_4 0.000 0.000 4.992 -53.021 0.000 0.000 7.203 5.830 23.435 38.820 0.000 0.095 0.000 0.000 -23.381 0.000 -2.202 -1.771
DATACENTER_BOT_ZN_6 0.000 0.000 0.000 -138.132 0.000 0.000 0.950 3.264 153.881 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 -19.963
DATACENTER_MID_ZN_6 0.000 0.000 2.294 -1225.201 0.000 0.000 9.500 32.637 1538.806 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 -358.036
DATACENTER_TOP_ZN_6 0.000 0.000 0.722 -115.324 0.000 0.000 0.954 3.264 153.881 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 -43.496
DATACENTER_BASEMENT_ZN_6 0.000 -7138.860 0.000 0.000 0.000 0.000 20.569 38.227 7494.857 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 -414.793
GROUNDFLOOR_PLENUM 1.776 -60.918 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.102 61.762 0.000 0.000 0.000 -2.723 0.000
MIDFLOOR_PLENUM 50.004 -403.547 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.909 397.241 0.000 0.000 0.000 -45.607 -0.005
TOPFLOOR_PLENUM 24.842 -65.068 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.162 44.712 0.000 0.000 0.000 -4.648 -0.008
Total Facility 76.622 -7668.393 130.153 -10155.560 0.000 0.000 1554.784 2029.321 14676.396 2024.589 0.000 7.065 809.757 0.000 -1413.844 0.000 -160.188 -1910.708


Peak Cooling Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [W] HVAC Zone Eq & Other Sensible Air Cooling [W] HVAC Terminal Unit Sensible Air Heating [W] HVAC Terminal Unit Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
BASEMENT 26-DEC-04:01 0.00 0.00 0.00 -98194.20 0.00 0.00 0.00 657.72 13457.54 0.00 0.00 0.00 84078.93 0.00 -0.00 0.00 0.00 0.00
CORE_BOTTOM 13-NOV-04:02 0.00 0.00 0.00 -83782.25 0.00 0.00 0.00 590.68 5937.65 0.00 0.00 0.00 77253.93 0.00 -0.00 0.00 0.00 0.00
CORE_MID 01-JUL-05:04 0.00 0.00 0.00 -726334.41 0.00 0.00 8677.82 11812.12 76473.61 0.00 0.00 0.00 629370.86 0.00 -0.00 0.00 0.00 0.00
CORE_TOP 02-SEP-05:04 0.00 0.00 0.00 -73070.46 0.00 0.00 839.84 1181.21 7647.36 0.00 0.00 0.00 63402.05 0.00 -0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_3 16-JUL-16:21 0.00 0.00 0.00 -14501.73 0.00 0.00 42.74 35.29 720.18 3639.33 0.00 25.81 10038.38 0.00 -0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_2 27-AUG-09:42 0.00 0.00 0.00 -15296.56 0.00 0.00 24.43 22.74 464.11 9859.54 0.00 0.00 4926.72 0.00 -0.00 0.00 -0.99 0.00
PERIMETER_BOT_ZN_1 09-OCT-14:12 0.00 0.00 0.00 -18033.86 0.00 0.00 37.93 35.29 720.19 12015.92 0.00 0.00 5227.45 0.00 -0.00 0.00 -2.91 0.00
PERIMETER_BOT_ZN_4 16-JUL-16:21 0.00 0.00 0.00 -21293.30 0.00 0.00 20.43 22.74 464.11 9418.17 0.00 12.45 11355.40 0.00 -0.00 0.00 0.00 0.00
PERIMETER_MID_ZN_3 04-AUG-03:02 0.00 0.00 0.00 -112089.75 0.00 0.00 0.00 741.66 7455.61 0.00 0.00 0.00 108046.48 0.00 -4090.36 0.00 -63.64 0.00
PERIMETER_MID_ZN_2 27-AUG-08:32 0.00 0.00 0.00 -154786.85 0.00 0.00 246.93 227.41 4641.14 107046.93 0.00 0.00 42682.34 0.00 -0.00 0.00 -57.89 0.00
PERIMETER_MID_ZN_1 09-OCT-14:22 0.00 0.00 0.00 -169508.26 0.00 0.00 378.59 352.89 7201.95 117556.40 0.00 0.00 44103.11 0.00 -0.00 0.00 -84.67 0.00
PERIMETER_MID_ZN_4 13-AUG-16:51 0.00 0.00 0.00 -179398.70 0.00 0.00 210.62 227.41 4641.11 105441.01 0.00 198.62 68679.93 0.00 -0.00 0.00 0.00 0.00
PERIMETER_TOP_ZN_3 13-AUG-16:51 0.00 0.00 0.00 -15369.62 0.00 0.00 43.37 35.29 720.18 2309.45 0.00 68.38 12192.96 0.00 -0.00 0.00 0.00 0.00
PERIMETER_TOP_ZN_2 27-AUG-08:32 0.00 0.00 0.00 -15841.86 0.00 0.00 24.69 22.74 464.11 10676.41 0.00 0.00 4661.26 0.00 -0.00 0.00 -7.36 0.00
PERIMETER_TOP_ZN_1 09-OCT-13:53 0.00 0.00 0.00 -18602.75 0.00 0.00 38.43 35.29 720.19 12223.97 0.00 0.00 5595.14 0.00 -0.00 0.00 -10.28 0.00
PERIMETER_TOP_ZN_4 13-AUG-16:51 0.00 0.00 0.00 -19807.64 0.00 0.00 19.77 22.74 464.11 10461.87 0.00 19.82 8819.32 0.00 -0.00 0.00 0.00 0.00
DATACENTER_BOT_ZN_6 13-AUG-18:40 0.00 0.00 0.00 -7858.10 0.00 0.00 0.00 15.83 7794.42 0.00 0.00 0.00 47.85 0.00 -0.00 0.00 0.00 0.00
DATACENTER_MID_ZN_6 13-AUG-18:40 0.00 0.00 0.00 -73984.37 0.00 0.00 0.00 158.32 77944.22 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 -4118.17
DATACENTER_TOP_ZN_6 13-AUG-19:10 0.00 0.00 0.00 -7648.82 0.00 0.00 0.00 15.83 7794.42 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 -161.44
DATACENTER_BASEMENT_ZN_6 07-AUG-16:00 0.00 -366909.35 0.00 0.00 0.00 0.00 2183.10 3337.76 379632.52 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 -18244.04
GROUNDFLOOR_PLENUM 17-JUL-05:15 0.00 -13048.47 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 13050.08 0.00 -0.00 0.00 -1.61 0.00
MIDFLOOR_PLENUM 11-AUG-05:03 0.00 -77699.70 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 77855.54 0.00 -0.00 0.00 -155.84 0.00
TOPFLOOR_PLENUM 07-JUL-15:10 0.00 -19505.81 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 28.57 19477.24 0.00 -0.00 0.00 0.00 0.00
Total Facility 28-AUG-05:02 0.00 -419282.84 0.00 -1397624.61 0.00 0.00 16136.83 22094.05 616289.16 0.00 0.00 0.00 1205511.67 0.00 -42641.66 0.00 -482.60 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [W] HVAC Zone Eq & Other Sensible Air Cooling [W] HVAC Terminal Unit Sensible Air Heating [W] HVAC Terminal Unit Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
BASEMENT 08-JUL-15:02 0.00 0.00 19397.59 0.00 0.00 0.00 1040.25 1973.00 13457.54 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 -35868.38
CORE_BOTTOM - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
CORE_MID 09-JAN-06:01 0.00 0.00 324966.82 0.00 0.00 0.00 11487.56 11812.12 76473.61 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 -424740.10
CORE_TOP 09-JAN-04:01 0.00 0.00 70484.48 0.00 0.00 0.00 0.00 590.68 5937.62 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 -77012.78
PERIMETER_BOT_ZN_3 13-FEB-06:01 0.00 0.00 9719.14 0.00 0.00 0.00 146.02 148.31 960.25 0.00 0.00 0.00 0.00 0.00 -4927.33 0.00 -92.28 -5954.11
PERIMETER_BOT_ZN_2 13-FEB-06:01 0.00 0.00 7532.11 0.00 0.00 0.00 93.98 95.58 618.82 0.00 0.00 0.00 0.00 0.00 -3283.07 0.00 -61.58 -4995.85
PERIMETER_BOT_ZN_1 09-JAN-05:01 0.00 0.00 12134.64 0.00 0.00 0.00 0.00 148.32 745.57 0.00 0.00 0.00 0.00 0.00 -3735.64 0.00 -224.00 -9068.89
PERIMETER_BOT_ZN_4 09-JAN-06:01 0.00 0.00 5274.95 0.00 0.00 0.00 94.15 95.58 618.81 0.00 0.00 0.00 0.00 0.00 -2814.90 0.00 -37.40 -3231.19
PERIMETER_MID_ZN_3 13-FEB-04:01 0.00 0.00 115589.26 0.00 0.00 0.00 0.00 741.66 7455.61 0.00 0.00 0.00 0.00 0.00 -40799.41 0.00 -8522.53 -74464.59
PERIMETER_MID_ZN_2 09-JAN-04:01 0.00 0.00 126500.44 0.00 0.00 0.00 0.00 477.95 4804.68 0.00 0.00 0.00 0.00 0.00 -21630.93 0.00 -2821.91 -107330.23
PERIMETER_MID_ZN_1 09-JAN-04:01 0.00 0.00 130785.36 0.00 0.00 0.00 0.00 741.67 7455.72 0.00 0.00 0.00 0.00 0.00 -33318.57 0.00 -4301.47 -101362.72
PERIMETER_MID_ZN_4 09-JAN-04:01 0.00 0.00 124451.27 0.00 0.00 0.00 0.00 477.95 4804.65 0.00 0.00 0.00 0.00 0.00 -23273.70 0.00 -2943.08 -103517.09
PERIMETER_TOP_ZN_3 12-FEB-05:53 0.00 0.00 14043.71 0.00 0.00 0.00 0.00 74.17 559.17 0.00 0.00 0.00 0.00 0.00 -5078.25 0.00 -1275.97 -8322.83
PERIMETER_TOP_ZN_2 12-FEB-05:53 0.00 0.00 13656.16 0.00 0.00 0.00 0.00 47.80 360.35 0.00 0.00 0.00 0.00 0.00 -3270.81 0.00 -867.10 -9926.40
PERIMETER_TOP_ZN_1 12-FEB-05:53 0.00 0.00 15778.47 0.00 0.00 0.00 0.00 74.17 559.18 0.00 0.00 0.00 0.00 0.00 -4954.30 0.00 -1296.29 -10161.23
PERIMETER_TOP_ZN_4 09-JAN-04:01 0.00 0.00 14913.51 0.00 0.00 0.00 0.00 47.80 480.46 0.00 0.00 0.00 0.00 0.00 -2072.74 0.00 -340.91 -13028.12
DATACENTER_BOT_ZN_6 - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
DATACENTER_MID_ZN_6 08-JAN-19:10 0.00 0.00 5148.52 0.00 0.00 0.00 0.00 158.32 19486.06 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 -24792.90
DATACENTER_TOP_ZN_6 22-JAN-18:50 0.00 0.00 565.76 0.00 0.00 0.00 0.00 15.83 1948.61 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 -2530.20
DATACENTER_BASEMENT_ZN_6 - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GROUNDFLOOR_PLENUM 26-DEC-04:01 11118.03 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 -457.12 -10660.90
MIDFLOOR_PLENUM 01-NOV-05:02 56368.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 -1628.08 -54740.38
TOPFLOOR_PLENUM 13-FEB-05:22 22086.28 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 -1245.10 -20841.18
Total Facility 09-JAN-06:01 -159260.37 101512.70 941732.49 -101512.70 0.00 0.00 21392.12 22094.05 261414.96 0.00 0.00 0.00 0.00 0.00 -147653.22 0.00 -6853.60 -932866.43



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Origin of D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Calculation Method for Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA Environment Name of Peak System Population - Ps Date and Time of Last Peak System Population - Ps
VAV_BOT WITH REHEAT 9.3262 0.0000 0.0000 1.0000 Calculated from schedules 0.0000 8.6311 0.0000 1.0000 Not calculated 0.0000 0.0000    
VAV_MID WITH REHEAT 86.9540 0.0000 0.0000 1.0000 Calculated from schedules 0.0000 79.8945 0.0000 1.0000 Not calculated 0.0000 0.0000    
VAV_TOP WITH REHEAT 9.0050 0.0000 0.0000 1.0000 Calculated from schedules 0.0000 8.5710 0.0000 1.0000 Not calculated 0.0000 0.0000    
CAV_BAS 4.9470 0.0000 149.6021 1.0000 Calculated from schedules 1.2002 4.9470 0.2426 1.0000 Not calculated 1.2002 0.2426    
AIRLOOP DATACENTER BOT 0.4738 0.0000 1.9486 1.0000 Calculated from schedules 0.0156 0.4738 0.0330 1.0000 Not calculated 0.0156 0.0330    
AIRLOOP DATACENTER MID 4.5046 0.0000 19.4861 1.0000 Calculated from schedules 0.1563 4.5046 0.0347 1.0000 Not calculated 0.1563 0.0347    
AIRLOOP DATACENTER TOP 0.4573 0.0000 1.9486 1.0000 Calculated from schedules 0.0156 0.4573 0.0342 1.0000 Not calculated 0.0156 0.0342    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Origin of D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Calculation Method for Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA Environment Name of Peak System Population - Ps Date and Time of Last Peak System Population - Ps
VAV_BOT WITH REHEAT 4.6631 0.0000 0.0000 1.0000 Calculated from schedules 0.0000 2.7456 0.0000 1.0000 Not calculated 0.0000 0.0000    
VAV_MID WITH REHEAT 43.4770 0.0000 0.0000 1.0000 Calculated from schedules 0.0000 26.5235 0.0000 1.0000 Not calculated 0.0000 0.0000    
VAV_TOP WITH REHEAT 4.5025 0.0000 0.0000 1.0000 Calculated from schedules 0.0000 2.7266 0.0000 1.0000 Not calculated 0.0000 0.0000    
CAV_BAS 4.9470 0.0000 149.6021 1.0000 Calculated from schedules 1.2002 4.9470 1.0000 1.0000 Not calculated 1.2002 0.2426    
AIRLOOP DATACENTER BOT 0.4738 0.0000 1.9486 1.0000 Calculated from schedules 0.0156 0.4738 1.0000 1.0000 Not calculated 0.0156 0.0330    
AIRLOOP DATACENTER MID 4.5046 0.0000 19.4861 1.0000 Calculated from schedules 0.1563 4.5046 1.0000 1.0000 Not calculated 0.1563 0.0347    
AIRLOOP DATACENTER TOP 0.4573 0.0000 1.9486 1.0000 Calculated from schedules 0.0156 0.4573 1.0000 1.0000 Not calculated 0.0156 0.0342    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
BASEMENT CAV_BAS 0.002360 149.6021 0.000305 2779.43 1.2002 1.0000 1.2002 1.000 1.2002
CORE_BOTTOM VAV_BOT WITH REHEAT 0.000000 134.3532 0.000432 2496.12 0.0000 1.0000 0.0000 1.000 0.0000
CORE_MID VAV_MID WITH REHEAT 0.000000 1343.5320 0.000432 24961.20 0.0000 1.0000 0.0000 1.000 0.0000
CORE_TOP VAV_TOP WITH REHEAT 0.000000 134.3532 0.000432 2496.12 0.0000 1.0000 0.0000 1.000 0.0000
PERIMETER_BOT_ZN_3 VAV_BOT WITH REHEAT 0.000000 16.8694 0.000432 313.41 0.0000 1.0000 0.0000 1.000 0.0000
PERIMETER_BOT_ZN_2 VAV_BOT WITH REHEAT 0.000000 10.8713 0.000432 201.98 0.0000 1.0000 0.0000 1.000 0.0000
PERIMETER_BOT_ZN_1 VAV_BOT WITH REHEAT 0.000000 16.8698 0.000432 313.42 0.0000 1.0000 0.0000 1.000 0.0000
PERIMETER_BOT_ZN_4 VAV_BOT WITH REHEAT 0.000000 10.8713 0.000432 201.98 0.0000 1.0000 0.0000 1.000 0.0000
PERIMETER_MID_ZN_3 VAV_MID WITH REHEAT 0.000000 168.6939 0.000432 3134.13 0.0000 1.0000 0.0000 1.000 0.0000
PERIMETER_MID_ZN_2 VAV_MID WITH REHEAT 0.000000 108.7127 0.000432 2019.75 0.0000 1.0000 0.0000 1.000 0.0000
PERIMETER_MID_ZN_1 VAV_MID WITH REHEAT 0.000000 168.6975 0.000432 3134.20 0.0000 1.0000 0.0000 1.000 0.0000
PERIMETER_MID_ZN_4 VAV_MID WITH REHEAT 0.000000 108.7127 0.000432 2019.75 0.0000 1.0000 0.0000 1.000 0.0000
PERIMETER_TOP_ZN_3 VAV_TOP WITH REHEAT 0.000000 16.8694 0.000432 313.41 0.0000 1.0000 0.0000 1.000 0.0000
PERIMETER_TOP_ZN_2 VAV_TOP WITH REHEAT 0.000000 10.8713 0.000432 201.98 0.0000 1.0000 0.0000 1.000 0.0000
PERIMETER_TOP_ZN_1 VAV_TOP WITH REHEAT 0.000000 16.8698 0.000432 313.42 0.0000 1.0000 0.0000 1.000 0.0000
PERIMETER_TOP_ZN_4 VAV_TOP WITH REHEAT 0.000000 10.8713 0.000432 201.98 0.0000 1.0000 0.0000 1.000 0.0000
DATACENTER_BOT_ZN_6 AIRLOOP DATACENTER BOT 0.002360 1.9486 0.000305 36.20 0.0156 1.0000 0.0156 1.000 0.0156
DATACENTER_MID_ZN_6 AIRLOOP DATACENTER MID 0.002360 19.4861 0.000305 362.03 0.1563 1.0000 0.1563 1.000 0.1563
DATACENTER_TOP_ZN_6 AIRLOOP DATACENTER TOP 0.002360 1.9486 0.000305 36.20 0.0156 1.0000 0.0156 1.000 0.0156


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
VAV_BOT WITH REHEAT   0.00 0.000432 3526.9033 0.0000 0.0000 0.0000
VAV_MID WITH REHEAT   0.00 0.000432 35269.0328 0.0000 0.0000 0.0000
VAV_TOP WITH REHEAT   0.00 0.000432 3526.9033 0.0000 0.0000 0.0000
CAV_BAS 0.002360 149.60 0.000305 2779.4266 1.2002 1.2002 1.2002
AIRLOOP DATACENTER BOT 0.002360 1.95 0.000305 36.2027 0.0156 0.0156 0.0156
AIRLOOP DATACENTER MID 0.002360 19.49 0.000305 362.0274 0.1563 0.1563 0.1563
AIRLOOP DATACENTER TOP 0.002360 1.95 0.000305 36.2027 0.0156 0.0156 0.0156


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
BASEMENT CAV_BAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 4.9470 4.9470 4.9470 No 1.2002 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
CORE_BOTTOM VAV_BOT WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 5.4082 5.4082 1.8712 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
CORE_MID VAV_MID WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 50.7868 50.7868 18.2325 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
CORE_TOP VAV_TOP WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 5.0395 5.0395 1.8646 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_BOT_ZN_3 VAV_BOT WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.8731 0.8731 0.2349 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_BOT_ZN_2 VAV_BOT WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.8785 0.8785 0.1757 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_BOT_ZN_1 VAV_BOT WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 1.0186 1.0186 0.2343 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_BOT_ZN_4 VAV_BOT WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 1.1477 1.1477 0.2295 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_MID_ZN_3 VAV_MID WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 8.1513 8.1513 2.2905 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_MID_ZN_2 VAV_MID WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 9.0373 9.0373 1.8075 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_MID_ZN_1 VAV_MID WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 9.4617 9.4617 2.2897 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_MID_ZN_4 VAV_MID WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 9.5168 9.5168 1.9034 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_TOP_ZN_3 VAV_TOP WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.9332 0.9332 0.2342 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_TOP_ZN_2 VAV_TOP WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.9269 0.9269 0.1854 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_TOP_ZN_1 VAV_TOP WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 1.0661 1.0661 0.2346 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_TOP_ZN_4 VAV_TOP WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 1.0393 1.0393 0.2079 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
DATACENTER_BOT_ZN_6 AIRLOOP DATACENTER BOT AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4738 0.4738 0.4738 No 0.0156 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
DATACENTER_MID_ZN_6 AIRLOOP DATACENTER MID AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 4.5046 4.5046 4.5046 No 0.1563 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
DATACENTER_TOP_ZN_6 AIRLOOP DATACENTER TOP AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4573 0.4573 0.4573 No 0.0156 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
VAV_BOT WITH REHEAT 9.3262 8.6311 9.3262 2.7456 0.0000 1.0000
VAV_MID WITH REHEAT 86.9540 79.8945 86.9540 26.5235 0.0000 1.0000
VAV_TOP WITH REHEAT 9.0050 8.5710 9.0050 2.7266 0.0000 1.0000
CAV_BAS 4.9470 4.9470 4.9470 4.9470 1.2002 1.0000
AIRLOOP DATACENTER BOT 0.4738 0.4738 0.4738 0.4738 0.0156 1.0000
AIRLOOP DATACENTER MID 4.5046 4.5046 4.5046 4.5046 0.1563 1.0000
AIRLOOP DATACENTER TOP 0.4573 0.4573 0.4573 0.4573 0.0156 1.0000


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
BASEMENT CAV_BAS AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 4.9470 4.9470 4.9470 No 1.2002 1.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
CORE_BOTTOM VAV_BOT WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 2.7041 2.7041 1.8712 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
CORE_MID VAV_MID WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 25.3934 25.3934 18.2325 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
CORE_TOP VAV_TOP WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 2.5198 2.5198 1.8646 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_BOT_ZN_3 VAV_BOT WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.4366 0.4366 0.2349 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_BOT_ZN_2 VAV_BOT WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.4393 0.4393 0.1757 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_BOT_ZN_1 VAV_BOT WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.5093 0.5093 0.2343 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_BOT_ZN_4 VAV_BOT WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.5739 0.5739 0.2295 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_MID_ZN_3 VAV_MID WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 4.0757 4.0757 2.2905 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_MID_ZN_2 VAV_MID WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 4.5187 4.5187 1.8075 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_MID_ZN_1 VAV_MID WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 4.7309 4.7309 2.2897 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_MID_ZN_4 VAV_MID WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 4.7584 4.7584 1.9034 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_TOP_ZN_3 VAV_TOP WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.4666 0.4666 0.2342 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_TOP_ZN_2 VAV_TOP WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.4635 0.4635 0.1854 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_TOP_ZN_1 VAV_TOP WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.5331 0.5331 0.2346 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_TOP_ZN_4 VAV_TOP WITH REHEAT AIRTERMINAL:SINGLEDUCT:VAV:REHEAT 0.5196 0.5196 0.2079 No 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000
DATACENTER_BOT_ZN_6 AIRLOOP DATACENTER BOT AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4738 0.4738 0.4738 No 0.0156 1.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
DATACENTER_MID_ZN_6 AIRLOOP DATACENTER MID AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 4.5046 4.5046 4.5046 No 0.1563 1.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
DATACENTER_TOP_ZN_6 AIRLOOP DATACENTER TOP AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4573 0.4573 0.4573 No 0.0156 1.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
VAV_BOT WITH REHEAT 4.6631 2.7456 2.7456 2.7456 0.0000 1.0000
VAV_MID WITH REHEAT 43.4770 26.5235 26.5235 26.5235 0.0000 1.0000
VAV_TOP WITH REHEAT 4.5025 2.7266 2.7266 2.7266 0.0000 1.0000
CAV_BAS 4.9470 4.9470 4.9470 4.9470 1.2002 1.0000
AIRLOOP DATACENTER BOT 0.4738 0.4738 0.4738 0.4738 0.0156 1.0000
AIRLOOP DATACENTER MID 4.5046 4.5046 4.5046 4.5046 0.1563 1.0000
AIRLOOP DATACENTER TOP 0.4573 0.4573 0.4573 0.4573 0.0156 1.0000



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Sec1.1A-General Information

Data
Weather File RUNPERIOD 1 ** Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190
Total gross floor area [m2] 46320.38
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
BASEMENT 2779.43 2779.43 0.00 113.98
CORE_BOTTOM 2496.12 2496.12 0.00 113.98
CORE_MID 2496.12 2496.12 0.00 113.98
CORE_TOP 2496.12 2496.12 0.00 113.98
PERIMETER_BOT_ZN_3 313.41 313.41 0.00 113.98
PERIMETER_BOT_ZN_2 201.98 201.98 0.00 113.98
PERIMETER_BOT_ZN_1 313.42 313.42 0.00 113.98
PERIMETER_BOT_ZN_4 201.98 201.98 0.00 113.98
PERIMETER_MID_ZN_3 313.41 313.41 0.00 113.98
PERIMETER_MID_ZN_2 201.98 201.98 0.00 96.54
PERIMETER_MID_ZN_1 313.42 313.42 0.00 113.98
PERIMETER_MID_ZN_4 201.98 201.98 0.00 113.98
PERIMETER_TOP_ZN_3 313.41 313.41 0.00 113.98
PERIMETER_TOP_ZN_2 201.98 201.98 0.00 113.98
PERIMETER_TOP_ZN_1 313.42 313.42 0.00 113.98
PERIMETER_TOP_ZN_4 201.98 201.98 0.00 113.98
DATACENTER_BOT_ZN_6 36.20 36.20 0.00 113.98
DATACENTER_MID_ZN_6 36.20 36.20 0.00 113.98
DATACENTER_TOP_ZN_6 36.20 36.20 0.00 113.98
DATACENTER_BASEMENT_ZN_6 783.68 783.68 0.00 113.98
GROUNDFLOOR_PLENUM 3563.11 3563.11 0.00 0.00
MIDFLOOR_PLENUM 3563.11 3563.11 0.00 0.00
TOPFLOOR_PLENUM 3563.11 3563.11 0.00 0.00
Totals 46320.38 46320.38 0.00  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 27.33
Number of hours cooling loads not met 143.50
Number of hours not met 170.83


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electricity Energy Use [GJ] Electricity Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Gasoline Use [GJ] Gasoline Demand [W] Diesel Use [GJ] Diesel Demand [W] Coal Use [GJ] Coal Demand [W] Fuel Oil No 1 Use [GJ] Fuel Oil No 1 Demand [W] Fuel Oil No 2 Use [GJ] Fuel Oil No 2 Demand [W] Propane Use [GJ] Propane Demand [W] Other Fuel 1 Use [GJ] Other Fuel 1 Demand [W] Other Fuel 2 Use [GJ] Other Fuel 2 Demand [W] District Cooling Use [GJ] District Cooling Demand [W] District Heating Use [GJ] District Heating Demand [W]
Heating -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 15.01
Heating -- Boiler 0.00 0.00 375.10 1079376.27 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heating -- Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling -- General 1574.96 261918.69 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 7163.44 369582.79 0.00 0.00
Interior Lighting -- LightsWired 2029.32 198743.45 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting -- General 327.97 37611.08 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment -- MiscPlug 5334.97 305206.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment -- DataCenterPlugLoads 9341.42 473165.59 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment -- Transformer 54.48 3387.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment -- ComputerHVAC 1349.07 68333.87 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment -- ElevatorLift 1848.78 113101.96 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment -- ElevatorLightsFan 5.83 376.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans -- General 1159.91 232032.16 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps -- General 647.80 62594.34 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection -- General 475.90 52437.43 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery -- General 45.36 5613.48 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- Water Heater 0.00 0.00 657.70 79713.29 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 14676.40 24195.80
Natural Gas 0.00 1032.81
Additional 0.00 7163.44
Total 14676.40 32392.04


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting (All) 43.81
Space Heating 0.00
Space Cooling 34.00
Fans (All) 25.04
Service Water Heating 0.00
Receptacle Equipment 316.85
Miscellaneous (All) 522.36
Subtotal 522.36


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 8.10
Service Water Heating 14.20
Miscellaneous (All) 22.30
Subtotal 22.30


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Subtotal 0.00
Miscellaneous 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting (All) 6.26
Space Heating 1.16
Space Cooling 26.98
Fans (All) 3.58
Service Water Heating 2.03
Receptacle Equipment 45.31
Miscellaneous 14.68


Schedules-Equivalent Full Load Hours (Schedule Type=Fraction)

Equivalent Full Load Hours of Operation Per Year [hr] Hours > 1% [hr]
EXTERIOR_LIGHTING_SCHEDULE_A 6570. 6570.
EXTERIOR_LIGHTING_SCHEDULE_B 8103. 8760.
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 4472. 4472.
EXTERIOR_LIGHTING_SCHEDULE_B_2016 7665. 8760.
EXTERIOR_LIGHTING_SCHEDULE_C_2016 6752. 8760.
ALWAYS_ON 8760. 8760.
EXTERIOR_LGT_ALWAYS_ON 8760. 8760.
EXTERIOR_LGT_189_1 6828. 8760.
ALWAYS_OFF 0. 0.
LTG_SCH_OFFICE 2362. 8760.
LTG_SCH_DATACENTER 2921. 8760.
EXTERIOR_LIGHT_SCH 4380. 4380.
BLDG_EQUIP_SCH 4049. 8760.
DATACENTER_EQUIP_SCH 5478. 8760.
BLDG_OCC_SCH 2528. 5992.
BLDG_OCC_SCH_W_SB 1878. 5056.
BLDG_OCC_SCH_WO_SB 2557. 5992.
BLDG_ELEVATORS 2270. 8760.
ELEV_LIGHT_FAN_SCH_24_7 8760. 8760.
ELEV_LIGHT_FAN_SCH_ADD_DF 2154. 8760.
BLDG_SWH_SCH 1474. 6570.
WORK_EFF_SCH 0. 0.
INFIL_SCH 3976. 3976.
INFIL_SCH_PNNL 5172. 8760.
INFIL_HALF_ON_SCH 6368. 8760.
FAN_SCH 8760. 8760.
REHEATCOILAVAILSCHED 8760. 8760.
COOLINGCOILAVAILSCHED 8760. 8760.
MINOA_MOTORIZEDDAMPER_SCHED 4472. 4472.
MINOA_SCHED 8760. 8760.
CORE_BOTTOM SUB CAT LATENT FRACT SCHED 438. 8760.
CORE_BOTTOM SUB CAT SENSIBLE FRACT SCHED 1752. 8760.
CORE_MID SUB CAT LATENT FRACT SCHED 438. 8760.
CORE_MID SUB CAT SENSIBLE FRACT SCHED 1752. 8760.
CORE_TOP SUB CAT LATENT FRACT SCHED 438. 8760.
CORE_TOP SUB CAT SENSIBLE FRACT SCHED 1752. 8760.
SUPPLYFANSCH 8760. 8760.
PERIMETER_MID_ZN_2_MDP_SCH 1565. 7824.


Schedules-SetPoints (Schedule Type=Temperature)

First Object Used Month Assumed 11am First Wednesday [C] Days with Same 11am Value 11pm First Wednesday [C] Days with Same 11pm Value
HTGSETP_DC_SCH DATACENTER COOLING SETPOINTS DUAL SP CONTROL January 18.00 365 18.00 365
CLGSETP_DC_SCH DATACENTER COOLING SETPOINTS DUAL SP CONTROL July 27.00 365 27.00 365
HTGSETP_SCH_YES_OPTIMUM_STARTSTOP CORE_BOTTOM DUAL SP CONTROL January 21.00 365 15.60 365
CLGSETP_SCH_YES_OPTIMUM_STARTSTOP CORE_BOTTOM DUAL SP CONTROL July 24.00 365 26.70 365



Table of Contents

Report: Annual Thermal Resilience Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Heat Index Hours

Safe (≤ 26.7°C) [hr] Caution (> 26.7, ≤ 32.2°C) [hr] Extreme Caution (> 32.2, ≤ 39.4°C) [hr] Danger (> 39.4, ≤ 51.7°C) [hr] Extreme Danger (> 51.7°C) [hr]
BASEMENT 8109.67 650.33 0.00 0.00 0.00
CORE_BOTTOM 8721.50 38.50 0.00 0.00 0.00
CORE_MID 8760.00 0.00 0.00 0.00 0.00
CORE_TOP 8760.00 0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_3 8745.83 14.17 0.00 0.00 0.00
PERIMETER_BOT_ZN_2 8684.00 76.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_1 8698.33 61.67 0.00 0.00 0.00
PERIMETER_BOT_ZN_4 7977.50 782.50 0.00 0.00 0.00
PERIMETER_MID_ZN_3 8753.00 7.00 0.00 0.00 0.00
PERIMETER_MID_ZN_2 8636.17 123.83 0.00 0.00 0.00
PERIMETER_MID_ZN_1 8698.33 61.67 0.00 0.00 0.00
PERIMETER_MID_ZN_4 8285.33 474.67 0.00 0.00 0.00
PERIMETER_TOP_ZN_3 8729.83 30.17 0.00 0.00 0.00
PERIMETER_TOP_ZN_2 8573.17 186.83 0.00 0.00 0.00
PERIMETER_TOP_ZN_1 8650.17 109.83 0.00 0.00 0.00
PERIMETER_TOP_ZN_4 8272.33 487.67 0.00 0.00 0.00
DATACENTER_BOT_ZN_6 7108.17 1651.83 0.00 0.00 0.00
DATACENTER_MID_ZN_6 7073.33 1686.67 0.00 0.00 0.00
DATACENTER_TOP_ZN_6 7048.33 1711.67 0.00 0.00 0.00
DATACENTER_BASEMENT_ZN_6 0.00 8760.00 0.00 0.00 0.00
GROUNDFLOOR_PLENUM 8760.00 0.00 0.00 0.00 0.00
MIDFLOOR_PLENUM 8760.00 0.00 0.00 0.00 0.00
TOPFLOOR_PLENUM 8599.33 160.67 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00
Max 8760.00 8760.00 0.00 0.00 0.00
Average 8017.58 742.42 0.00 0.00 0.00
Sum 184404.33 17075.67 0.00 0.00 0.00


Heat Index OccupantHours

Safe (≤ 26.7°C) [hr] Caution (> 26.7, ≤ 32.2°C) [hr] Extreme Caution (> 32.2, ≤ 39.4°C) [hr] Danger (> 39.4, ≤ 51.7°C) [hr] Extreme Danger (> 51.7°C) [hr]
BASEMENT 366663.00 1953.00 0.00 0.00 0.00
CORE_BOTTOM 330723.00 90.00 0.00 0.00 0.00
CORE_MID 330813.00 0.00 0.00 0.00 0.00
CORE_TOP 330813.00 0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_3 38925.00 0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_2 24909.00 0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_1 38925.00 0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_4 24909.00 0.00 0.00 0.00 0.00
PERIMETER_MID_ZN_3 38925.00 0.00 0.00 0.00 0.00
PERIMETER_MID_ZN_2 18354.00 0.00 0.00 0.00 0.00
PERIMETER_MID_ZN_1 38925.00 0.00 0.00 0.00 0.00
PERIMETER_MID_ZN_4 24909.00 0.00 0.00 0.00 0.00
PERIMETER_TOP_ZN_3 38925.00 0.00 0.00 0.00 0.00
PERIMETER_TOP_ZN_2 24909.00 0.00 0.00 0.00 0.00
PERIMETER_TOP_ZN_1 38925.00 0.00 0.00 0.00 0.00
PERIMETER_TOP_ZN_4 24909.00 0.00 0.00 0.00 0.00
DATACENTER_BOT_ZN_6 1351.83 916.17 0.00 0.00 0.00
DATACENTER_MID_ZN_6 1335.17 932.83 0.00 0.00 0.00
DATACENTER_TOP_ZN_6 1324.83 943.17 0.00 0.00 0.00
DATACENTER_BASEMENT_ZN_6 0.00 103395.00 0.00 0.00 0.00
GROUNDFLOOR_PLENUM 0.00 0.00 0.00 0.00 0.00
MIDFLOOR_PLENUM 0.00 0.00 0.00 0.00 0.00
TOPFLOOR_PLENUM 0.00 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00
Max 366663.00 103395.00 0.00 0.00 0.00
Average 75629.25 4705.66 0.00 0.00 0.00
Sum 1739472.83 108230.17 0.00 0.00 0.00


Humidex Hours

Little to no Discomfort (≤ 29) [hr] Some Discomfort (> 29, ≤ 40) [hr] Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] Dangerous (> 45, ≤ 50) [hr] Heat Stroke Quite Possible (> 50) [hr]
BASEMENT 6304.17 2455.83 0.00 0.00 0.00
CORE_BOTTOM 7744.00 1016.00 0.00 0.00 0.00
CORE_MID 7598.67 1161.33 0.00 0.00 0.00
CORE_TOP 7713.17 1046.83 0.00 0.00 0.00
PERIMETER_BOT_ZN_3 7594.67 1165.33 0.00 0.00 0.00
PERIMETER_BOT_ZN_2 7823.83 936.17 0.00 0.00 0.00
PERIMETER_BOT_ZN_1 7488.67 1271.33 0.00 0.00 0.00
PERIMETER_BOT_ZN_4 7025.50 1734.50 0.00 0.00 0.00
PERIMETER_MID_ZN_3 7525.67 1234.33 0.00 0.00 0.00
PERIMETER_MID_ZN_2 7452.00 1308.00 0.00 0.00 0.00
PERIMETER_MID_ZN_1 7383.00 1377.00 0.00 0.00 0.00
PERIMETER_MID_ZN_4 7270.00 1490.00 0.00 0.00 0.00
PERIMETER_TOP_ZN_3 7521.33 1238.67 0.00 0.00 0.00
PERIMETER_TOP_ZN_2 7462.83 1297.17 0.00 0.00 0.00
PERIMETER_TOP_ZN_1 7409.17 1350.83 0.00 0.00 0.00
PERIMETER_TOP_ZN_4 7328.33 1431.67 0.00 0.00 0.00
DATACENTER_BOT_ZN_6 7679.83 1080.17 0.00 0.00 0.00
DATACENTER_MID_ZN_6 7625.00 1135.00 0.00 0.00 0.00
DATACENTER_TOP_ZN_6 7609.00 1151.00 0.00 0.00 0.00
DATACENTER_BASEMENT_ZN_6 0.00 8760.00 0.00 0.00 0.00
GROUNDFLOOR_PLENUM 7147.00 1613.00 0.00 0.00 0.00
MIDFLOOR_PLENUM 7331.00 1429.00 0.00 0.00 0.00
TOPFLOOR_PLENUM 6547.83 2212.17 0.00 0.00 0.00
Min 0.00 936.17 0.00 0.00 0.00
Max 7823.83 8760.00 0.00 0.00 0.00
Average 7068.90 1691.10 0.00 0.00 0.00
Sum 162584.67 38895.33 0.00 0.00 0.00


Humidex OccupantHours

Little to no Discomfort (≤ 29) [hr] Some Discomfort (> 29, ≤ 40) [hr] Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] Dangerous (> 45, ≤ 50) [hr] Heat Stroke Quite Possible (> 50) [hr]
BASEMENT 345620.83 22995.17 0.00 0.00 0.00
CORE_BOTTOM 328811.17 2001.83 0.00 0.00 0.00
CORE_MID 328786.33 2026.67 0.00 0.00 0.00
CORE_TOP 328480.17 2332.83 0.00 0.00 0.00
PERIMETER_BOT_ZN_3 38925.00 0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_2 24909.00 0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_1 38925.00 0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_4 24907.83 1.17 0.00 0.00 0.00
PERIMETER_MID_ZN_3 38924.33 0.67 0.00 0.00 0.00
PERIMETER_MID_ZN_2 18354.00 0.00 0.00 0.00 0.00
PERIMETER_MID_ZN_1 38924.50 0.50 0.00 0.00 0.00
PERIMETER_MID_ZN_4 24908.17 0.83 0.00 0.00 0.00
PERIMETER_TOP_ZN_3 38924.17 0.83 0.00 0.00 0.00
PERIMETER_TOP_ZN_2 24908.33 0.67 0.00 0.00 0.00
PERIMETER_TOP_ZN_1 38924.00 1.00 0.00 0.00 0.00
PERIMETER_TOP_ZN_4 24908.17 0.83 0.00 0.00 0.00
DATACENTER_BOT_ZN_6 1596.17 671.83 0.00 0.00 0.00
DATACENTER_MID_ZN_6 1570.67 697.33 0.00 0.00 0.00
DATACENTER_TOP_ZN_6 1558.83 709.17 0.00 0.00 0.00
DATACENTER_BASEMENT_ZN_6 0.00 103395.00 0.00 0.00 0.00
GROUNDFLOOR_PLENUM 0.00 0.00 0.00 0.00 0.00
MIDFLOOR_PLENUM 0.00 0.00 0.00 0.00 0.00
TOPFLOOR_PLENUM 0.00 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00
Max 345620.83 103395.00 0.00 0.00 0.00
Average 74472.46 5862.45 0.00 0.00 0.00
Sum 1712866.67 134836.33 0.00 0.00 0.00


Heating SET Hours

SET ≤ 12.2°C Hours (°C) SET ≤ 12.2°C OccupantHours (°C) Longest SET ≤ 12.2°C Duration [hr] Start Time of the Longest SET ≤ 12.2°C Duration
None        


Cooling SET Hours

SET > 30°C Hours (°C) SET > 30°C OccupantHours (°C) Longest SET > 30°C Duration [hr] Start Time of the Longest SET > 30°C Duration
None        



Table of Contents

Report: Annual CO2 Resilience Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

CO2 Level Hours

Safe (<= 1000 ppm) [hr] Caution (> 1000, <= 5000 ppm) [hr] Hazard (> 5000 ppm) [hr]
None      


CO2 Level OccupantHours

Safe (<= 1000 ppm) [hr] Caution (> 1000, <= 5000 ppm) [hr] Hazard (> 5000 ppm) [hr]
None      



Table of Contents

Report: Annual Visual Resilience Summary

For: Entire Facility

Timestamp: 2023-10-16 09:05:17

Illuminance Level Hours

A Bit Dark (<= 100 lux) [hr] Dim (> 100, <= 300 lux) [hr] Adequate (> 300, <= 500 lux) [hr] Bright (>500 lux) [hr]
BASEMENT 0.00 0.00 0.00 0.00
CORE_BOTTOM 0.00 0.00 0.00 0.00
CORE_MID 0.00 0.00 0.00 0.00
CORE_TOP 0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_3 0.00 0.00 8760.00 0.00
PERIMETER_BOT_ZN_2 0.00 0.00 8760.00 0.00
PERIMETER_BOT_ZN_1 0.00 0.00 8760.00 0.00
PERIMETER_BOT_ZN_4 0.00 0.00 8760.00 0.00
PERIMETER_MID_ZN_3 0.00 0.00 8760.00 0.00
PERIMETER_MID_ZN_2 0.00 0.00 8760.00 0.00
PERIMETER_MID_ZN_1 0.00 0.00 8760.00 0.00
PERIMETER_MID_ZN_4 0.00 0.00 8760.00 0.00
PERIMETER_TOP_ZN_3 0.00 0.00 8760.00 0.00
PERIMETER_TOP_ZN_2 0.00 0.00 8760.00 0.00
PERIMETER_TOP_ZN_1 0.00 0.00 8760.00 0.00
PERIMETER_TOP_ZN_4 0.00 0.00 8760.00 0.00
DATACENTER_BOT_ZN_6 0.00 0.00 0.00 0.00
DATACENTER_MID_ZN_6 0.00 0.00 0.00 0.00
DATACENTER_TOP_ZN_6 0.00 0.00 0.00 0.00
DATACENTER_BASEMENT_ZN_6 0.00 0.00 0.00 0.00
GROUNDFLOOR_PLENUM 0.00 0.00 0.00 0.00
MIDFLOOR_PLENUM 0.00 0.00 0.00 0.00
TOPFLOOR_PLENUM 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00
Max 0.00 0.00 8760.00 0.00
Average 0.00 0.00 4570.43 0.00
Sum 0.00 0.00 105120.00 0.00


Illuminance Level OccupantHours

A Bit Dark (<= 100 lux) [hr] Dim (> 100, <= 300 lux) [hr] Adequate (> 300, <= 500 lux) [hr] Bright (>500 lux) [hr]
BASEMENT 0.00 0.00 0.00 0.00
CORE_BOTTOM 0.00 0.00 0.00 0.00
CORE_MID 0.00 0.00 0.00 0.00
CORE_TOP 0.00 0.00 0.00 0.00
PERIMETER_BOT_ZN_3 0.00 0.00 38925.00 0.00
PERIMETER_BOT_ZN_2 0.00 0.00 24909.00 0.00
PERIMETER_BOT_ZN_1 0.00 0.00 38925.00 0.00
PERIMETER_BOT_ZN_4 0.00 0.00 24909.00 0.00
PERIMETER_MID_ZN_3 0.00 0.00 38925.00 0.00
PERIMETER_MID_ZN_2 0.00 0.00 18354.00 0.00
PERIMETER_MID_ZN_1 0.00 0.00 38925.00 0.00
PERIMETER_MID_ZN_4 0.00 0.00 24909.00 0.00
PERIMETER_TOP_ZN_3 0.00 0.00 38925.00 0.00
PERIMETER_TOP_ZN_2 0.00 0.00 24909.00 0.00
PERIMETER_TOP_ZN_1 0.00 0.00 38925.00 0.00
PERIMETER_TOP_ZN_4 0.00 0.00 24909.00 0.00
DATACENTER_BOT_ZN_6 0.00 0.00 0.00 0.00
DATACENTER_MID_ZN_6 0.00 0.00 0.00 0.00
DATACENTER_TOP_ZN_6 0.00 0.00 0.00 0.00
DATACENTER_BASEMENT_ZN_6 0.00 0.00 0.00 0.00
GROUNDFLOOR_PLENUM 0.00 0.00 0.00 0.00
MIDFLOOR_PLENUM 0.00 0.00 0.00 0.00
TOPFLOOR_PLENUM 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00
Max 0.00 0.00 38925.00 0.00
Average 0.00 0.00 16367.35 0.00
Sum 0.00 0.00 376449.00 0.00



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR

For: Environment

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 3.965
February 7.937
March 13.764
April 17.213
May 20.837
June 24.797
July 26.063
August 26.547
September 22.525
October 16.026
November 11.940
December 7.696
   
Annual Sum or Average 16.653
Minimum of Months 3.965
Maximum of Months 26.547



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC

For: Environment

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 3.965
February 7.937
March 13.764
April 17.213
May 20.837
June 24.797
July 26.063
August 26.547
September 22.525
October 16.026
November 11.940
December 7.696
   
Annual Sum or Average 16.653
Minimum of Months 3.965
Maximum of Months 26.547



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2021

For: Environment

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 3.965
February 7.937
March 13.764
April 17.213
May 20.837
June 24.797
July 26.063
August 26.547
September 22.525
October 16.026
November 11.940
December 7.696
   
Annual Sum or Average 16.653
Minimum of Months 3.965
Maximum of Months 26.547



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND

For: Environment

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 3.965
February 7.937
March 13.764
April 17.213
May 20.837
June 24.797
July 26.063
August 26.547
September 22.525
October 16.026
November 11.940
December 7.696
   
Annual Sum or Average 16.653
Minimum of Months 3.965
Maximum of Months 26.547



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICELARGE

For: Environment

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 3.965
February 7.937
March 13.764
April 17.213
May 20.837
June 24.797
July 26.063
August 26.547
September 22.525
October 16.026
November 11.940
December 7.696
   
Annual Sum or Average 16.653
Minimum of Months 3.965
Maximum of Months 26.547



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL

For: Environment

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 3.965
February 7.937
March 13.764
April 17.213
May 20.837
June 24.797
July 26.063
August 26.547
September 22.525
October 16.026
November 11.940
December 7.696
   
Annual Sum or Average 16.653
Minimum of Months 3.965
Maximum of Months 26.547



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL

For: Environment

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 3.965
February 7.937
March 13.764
April 17.213
May 20.837
June 24.797
July 26.063
August 26.547
September 22.525
October 16.026
November 11.940
December 7.696
   
Annual Sum or Average 16.653
Minimum of Months 3.965
Maximum of Months 26.547



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3A

For: Environment

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 3.965
February 7.937
March 13.764
April 17.213
May 20.837
June 24.797
July 26.063
August 26.547
September 22.525
October 16.026
November 11.940
December 7.696
   
Annual Sum or Average 16.653
Minimum of Months 3.965
Maximum of Months 26.547



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_GA_ATLANTA

For: Environment

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 3.965
February 7.937
March 13.764
April 17.213
May 20.837
June 24.797
July 26.063
August 26.547
September 22.525
October 16.026
November 11.940
December 7.696
   
Annual Sum or Average 16.653
Minimum of Months 3.965
Maximum of Months 26.547



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: BASEMENT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.390431E+11 91435.55 23-JAN-05:01 -1.7 -3.5 0.565306E+10 7499.14 31-JAN-10:39 13.30 11.14
February 0.366701E+11 94143.23 21-FEB-04:03 6.70 4.44 0.513551E+10 7499.15 28-FEB-14:20 25.00 13.71
March 0.468193E+11 91400.92 27-MAR-03:02 10.50 5.44 0.613612E+10 7499.46 08-MAR-10:20 10.50 5.44
April 0.422073E+11 88155.65 11-APR-04:12 11.83 9.23 0.545090E+10 7499.25 03-APR-09:20 11.83 9.23
May 0.462499E+11 87863.66 10-MAY-04:03 8.90 4.54 0.590470E+10 7499.39 11-MAY-09:00 17.20 13.27
June 0.504484E+11 85670.03 09-JUN-04:03 14.32 9.21 0.588692E+10 7499.13 02-JUN-13:09 14.32 9.21
July 0.523869E+11 80181.04 03-JUL-03:02 17.80 16.72 0.547879E+10 7498.76 28-JUL-09:20 19.40 19.40
August 0.595988E+11 71182.15 14-AUG-03:02 25.40 20.64 0.614453E+10 7499.02 25-AUG-09:50 27.23 18.71
September 0.545898E+11 87711.09 29-SEP-04:02 11.78 11.10 0.546001E+10 7499.14 20-SEP-13:20 11.78 11.10
October 0.561316E+11 93418.51 30-OCT-03:13 8.90 8.90 0.567733E+10 7498.94 31-OCT-09:50 10.13 8.85
November 0.543395E+11 94806.51 13-NOV-04:02 5.40 2.09 0.562124E+10 7499.35 16-NOV-10:20 10.77 10.06
December 0.497822E+11 98197.18 26-DEC-04:01 3.90 2.94 0.547519E+10 7499.16 12-DEC-10:20 3.90 2.94
                     
Annual Sum or Average 0.588267E+12         0.680243E+11        
Minimum of Months 0.366701E+11 71182.15   -1.7 -3.5 0.513551E+10 7498.76   3.90 2.94
Maximum of Months 0.595988E+11 98197.18   25.40 20.64 0.614453E+10 7499.46   27.23 19.40



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: CORE_BOTTOM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.311923E+11 81106.41 02-JAN-05:01 3.30 2.57 0.503219E+10 6745.02 27-JAN-14:39 3.53 -2.0
February 0.336022E+11 76674.03 28-FEB-05:03 10.60 5.93 0.458647E+10 6738.30 13-FEB-14:20 10.60 5.93
March 0.497850E+11 77387.91 14-MAR-03:02 14.90 11.88 0.549821E+10 6735.18 08-MAR-10:09 14.90 11.88
April 0.538928E+11 77837.70 04-APR-03:02 15.10 14.40 0.488002E+10 6771.18 17-APR-13:50 28.72 16.68
May 0.492632E+11 78119.10 22-MAY-03:02 17.70 16.67 0.528580E+10 6735.15 19-MAY-13:09 17.70 16.67
June 0.575099E+11 74638.12 19-JUN-05:04 21.02 20.20 0.526769E+10 6734.82 09-JUN-09:00 21.02 20.20
July 0.633628E+11 77136.42 03-JUL-05:04 17.88 16.41 0.489335E+10 6734.61 17-JUL-09:00 27.80 22.02
August 0.702116E+11 70752.83 28-AUG-05:04 21.60 20.47 0.549446E+10 6734.62 25-AUG-13:50 21.60 20.47
September 0.498395E+11 81262.16 18-SEP-03:02 15.00 14.25 0.488366E+10 6734.82 22-SEP-13:39 26.50 17.31
October 0.485984E+11 80411.14 02-OCT-03:02 19.82 19.54 0.507962E+10 6734.68 30-OCT-09:00 11.10 11.10
November 0.462235E+11 83792.51 13-NOV-04:02 5.40 2.09 0.503036E+10 6735.72 22-NOV-10:20 4.07 0.68
December 0.423124E+11 82309.90 26-DEC-04:01 3.90 2.94 0.490164E+10 6746.45 18-DEC-10:20 3.90 2.94
                     
Annual Sum or Average 0.595794E+12         0.608335E+11        
Minimum of Months 0.311923E+11 70752.83   3.30 2.09 0.458647E+10 6734.61   3.53 -2.0
Maximum of Months 0.702116E+11 83792.51   21.60 20.47 0.549821E+10 6771.18   28.72 22.02



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: CORE_MID

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.213143E+11 21330.00 31-JAN-17:00 19.40 13.37 0.455992E+10 6734.26 31-JAN-14:20 19.40 13.37
February 0.226824E+11 68184.15 28-FEB-06:02 10.78 5.86 0.434031E+10 6734.75 22-FEB-14:09 10.78 5.86
March 0.345385E+11 71687.85 15-MAR-05:02 8.22 4.19 0.545500E+10 6744.83 23-MAR-09:30 9.15 7.98
April 0.355774E+11 72587.25 04-APR-05:02 15.60 14.96 0.486292E+10 6757.55 11-APR-13:09 26.70 16.01
May 0.416979E+11 71652.87 13-MAY-05:02 13.03 9.59 0.527612E+10 6735.11 11-MAY-09:00 13.03 9.59
June 0.449628E+11 72217.58 07-JUN-04:03 15.32 12.58 0.526377E+10 6734.80 09-JUN-09:00 24.40 15.46
July 0.453298E+11 72658.43 01-JUL-05:04 21.78 20.52 0.488981E+10 6734.60 05-JUL-09:20 28.87 23.62
August 0.487620E+11 72247.67 31-AUG-05:04 21.70 20.81 0.549141E+10 6734.61 10-AUG-13:50 21.70 20.81
September 0.402763E+11 71114.08 18-SEP-04:03 14.90 13.95 0.487315E+10 6734.80 22-SEP-13:50 26.60 17.45
October 0.346677E+11 72152.68 05-OCT-05:02 12.52 11.43 0.504371E+10 6734.87 26-OCT-09:09 8.95 6.10
November 0.289070E+11 69334.62 06-NOV-06:03 9.32 8.73 0.496498E+10 6734.93 16-NOV-10:09 10.68 10.03
December 0.242017E+11 66368.82 13-DEC-06:02 16.70 15.65 0.468690E+10 6736.01 15-DEC-10:09 6.47 3.46
                     
Annual Sum or Average 0.422918E+12         0.597080E+11        
Minimum of Months 0.213143E+11 21330.00   8.22 4.19 0.434031E+10 6734.26   6.47 3.46
Maximum of Months 0.487620E+11 72658.43   21.78 20.81 0.549141E+10 6757.55   28.87 23.62



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: CORE_TOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.150010E+11 18890.02 20-JAN-17:00 16.70 11.48 0.401981E+10 6552.93 20-JAN-14:00 16.70 11.48
February 0.176558E+11 30210.25 28-FEB-17:00 23.90 12.94 0.391958E+10 6734.71 22-FEB-14:00 23.90 12.94
March 0.287517E+11 70494.39 31-MAR-05:04 16.78 15.18 0.522022E+10 6734.67 14-MAR-09:09 16.78 15.18
April 0.326145E+11 70178.30 19-APR-05:02 16.02 14.35 0.478302E+10 6734.84 12-APR-13:39 16.02 14.35
May 0.423622E+11 70338.42 09-MAY-05:02 16.02 14.34 0.526345E+10 6761.93 19-MAY-13:50 30.50 18.50
June 0.489551E+11 72696.20 19-JUN-03:02 20.60 19.79 0.526374E+10 6734.76 09-JUN-09:00 20.60 19.79
July 0.505467E+11 72472.86 27-JUL-05:04 22.12 22.12 0.489123E+10 6734.51 27-JUL-09:09 21.10 20.75
August 0.539585E+11 72821.55 08-AUG-05:04 20.60 20.18 0.549461E+10 6734.58 25-AUG-13:09 30.18 18.86
September 0.398443E+11 73098.60 02-SEP-05:04 20.10 18.59 0.485583E+10 6734.69 15-SEP-13:30 28.05 18.25
October 0.294491E+11 68260.30 11-OCT-05:03 18.72 16.68 0.486332E+10 6734.61 12-OCT-09:09 13.58 9.42
November 0.218744E+11 45105.36 04-NOV-05:03 16.60 15.28 0.455037E+10 6734.64 03-NOV-09:00 16.60 15.28
December 0.177527E+11 26802.25 13-DEC-17:00 16.70 16.70 0.409408E+10 6734.47 14-DEC-14:00 15.00 10.54
                     
Annual Sum or Average 0.398766E+12         0.572193E+11        
Minimum of Months 0.150010E+11 18890.02   16.02 11.48 0.391958E+10 6552.93   13.58 9.42
Maximum of Months 0.539585E+11 73098.60   23.90 22.12 0.549461E+10 6761.93   30.50 20.75



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_BOT_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.216326E+10 3160.46 31-JAN-15:00 21.10 12.97 0.535376E+09 845.60 19-JAN-14:39 21.10 12.97
February 0.273430E+10 5312.33 28-FEB-15:00 25.00 13.71 0.518431E+09 845.64 22-FEB-14:09 25.00 13.71
March 0.482489E+10 6551.65 30-MAR-14:00 27.80 17.87 0.676406E+09 845.65 08-MAR-10:30 27.80 17.87
April 0.630680E+10 7285.06 19-APR-05:02 16.02 14.35 0.607567E+09 850.70 17-APR-13:50 16.02 14.35
May 0.702385E+10 10663.23 19-MAY-14:07 30.60 18.53 0.663116E+09 845.78 19-MAY-13:09 30.60 18.53
June 0.972282E+10 10595.77 16-JUN-05:03 20.68 19.81 0.662493E+09 845.64 02-JUN-13:00 20.68 19.81
July 0.107586E+11 14504.03 16-JUL-16:21 33.05 22.55 0.616134E+09 846.66 17-JUL-13:20 29.40 22.12
August 0.116387E+11 12918.85 06-AUG-17:42 32.20 22.79 0.691260E+09 845.82 10-AUG-13:39 30.77 23.76
September 0.680807E+10 10805.02 25-SEP-05:03 19.40 17.11 0.612483E+09 845.65 22-SEP-13:39 19.40 17.11
October 0.493713E+10 10451.67 02-OCT-05:03 18.22 18.22 0.626971E+09 845.61 16-OCT-13:00 25.00 19.11
November 0.386885E+10 4993.90 02-NOV-13:50 23.30 17.15 0.610759E+09 845.63 16-NOV-10:50 11.02 10.17
December 0.313044E+10 4874.81 13-DEC-12:00 20.00 17.41 0.572285E+09 845.63 11-DEC-10:00 20.00 17.41
                     
Annual Sum or Average 0.739178E+11         0.739328E+10        
Minimum of Months 0.216326E+10 3160.46   16.02 12.97 0.518431E+09 845.60   11.02 10.17
Maximum of Months 0.116387E+11 14504.03   33.05 22.79 0.691260E+09 850.70   30.77 23.76



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_BOT_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.168669E+10 2472.48 31-JAN-10:30 12.75 10.76 0.354373E+09 545.52 23-JAN-10:50 12.75 10.76
February 0.226990E+10 6111.45 27-FEB-09:40 12.23 5.46 0.338763E+09 544.96 28-FEB-10:00 20.60 11.95
March 0.393293E+10 6762.15 14-MAR-09:30 16.95 13.93 0.435554E+09 545.00 08-MAR-10:09 16.95 13.93
April 0.526334E+10 10712.24 16-APR-09:43 22.02 14.52 0.391939E+09 548.73 17-APR-13:50 28.72 16.68
May 0.617607E+10 14851.42 07-MAY-08:43 22.93 19.01 0.427748E+09 545.18 30-MAY-09:00 27.80 21.16
June 0.783962E+10 15069.06 04-JUN-08:53 24.40 18.28 0.427070E+09 545.24 05-JUN-09:00 28.90 20.65
July 0.842905E+10 15041.53 09-JUL-09:02 25.55 22.40 0.397034E+09 545.97 17-JUL-09:50 27.52 21.93
August 0.872597E+10 15302.35 27-AUG-09:42 26.83 21.78 0.445399E+09 545.61 14-AUG-09:50 26.83 21.78
September 0.579686E+10 14691.60 24-SEP-09:53 26.10 18.37 0.394567E+09 545.69 11-SEP-09:00 26.10 18.37
October 0.414348E+10 9665.96 09-OCT-09:33 21.83 17.14 0.403952E+09 544.95 16-OCT-13:00 25.00 19.11
November 0.290557E+10 5683.29 06-NOV-09:30 13.30 11.71 0.394443E+09 544.96 06-NOV-10:09 14.87 12.62
December 0.226517E+10 3190.90 11-DEC-10:30 13.35 10.86 0.369059E+09 544.97 11-DEC-10:00 15.00 12.11
                     
Annual Sum or Average 0.594347E+11         0.477990E+10        
Minimum of Months 0.168669E+10 2472.48   12.23 5.46 0.338763E+09 544.95   12.75 10.76
Maximum of Months 0.872597E+10 15302.35   26.83 22.40 0.445399E+09 548.73   28.90 21.93



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_BOT_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.341168E+10 8514.63 23-JAN-14:30 9.70 3.32 0.574932E+09 847.97 27-JAN-14:39 3.53 -2.0
February 0.437591E+10 17299.89 26-FEB-13:53 24.40 12.54 0.537543E+09 854.74 21-FEB-14:39 24.40 12.54
March 0.715278E+10 12981.49 30-MAR-13:30 27.25 18.02 0.679374E+09 847.11 30-MAR-13:30 27.25 18.02
April 0.790033E+10 12850.77 12-APR-13:20 28.17 16.72 0.608421E+09 877.64 12-APR-13:39 28.53 16.91
May 0.773731E+10 13017.00 19-MAY-14:07 30.60 18.53 0.662946E+09 867.69 15-MAY-13:20 30.60 18.53
June 0.987746E+10 12102.57 24-JUN-05:02 21.20 19.96 0.662445E+09 845.67 02-JUN-13:00 21.20 19.96
July 0.111066E+11 16938.91 16-JUL-15:02 33.30 22.53 0.616336E+09 846.06 31-JUL-13:00 30.60 24.81
August 0.132373E+11 17057.58 27-AUG-13:02 31.70 22.66 0.691894E+09 846.47 28-AUG-13:20 28.30 22.11
September 0.908760E+10 17490.52 24-SEP-12:32 28.70 19.86 0.613431E+09 846.42 08-SEP-13:39 28.70 19.86
October 0.825228E+10 18033.72 09-OCT-14:12 27.40 19.48 0.629606E+09 878.12 10-OCT-13:50 29.22 21.00
November 0.652643E+10 17711.08 11-NOV-13:53 21.10 11.67 0.620531E+09 860.39 06-NOV-14:09 21.10 11.67
December 0.531945E+10 17001.28 10-DEC-14:02 16.97 7.96 0.589442E+09 846.68 18-DEC-10:20 1.50 -2.3
                     
Annual Sum or Average 0.939852E+11         0.748690E+10        
Minimum of Months 0.341168E+10 8514.63   9.70 3.32 0.537543E+09 845.67   1.50 -2.3
Maximum of Months 0.132373E+11 18033.72   33.30 22.66 0.691894E+09 878.12   30.60 24.81



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_BOT_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.268835E+10 4634.21 23-JAN-16:30 10.00 3.54 0.365934E+09 544.94 30-JAN-14:00 16.70 10.51
February 0.367086E+10 15748.19 26-FEB-15:53 24.40 12.35 0.355732E+09 544.96 22-FEB-14:09 24.40 12.35
March 0.747081E+10 17806.43 26-MAR-18:03 19.82 9.28 0.445590E+09 544.99 08-MAR-10:09 19.82 9.28
April 0.990049E+10 19414.22 09-APR-16:52 21.70 10.78 0.396958E+09 550.73 14-APR-15:39 27.20 15.71
May 0.792349E+10 19821.88 21-MAY-17:32 25.97 19.50 0.428990E+09 545.20 19-MAY-13:09 25.97 19.50
June 0.108917E+11 19323.97 25-JUN-16:02 33.22 22.10 0.428177E+09 544.98 02-JUN-13:00 33.22 22.10
July 0.127930E+11 21299.66 16-JUL-16:21 33.05 22.55 0.398358E+09 544.95 17-JUL-09:00 27.80 22.02
August 0.148229E+11 20475.59 06-AUG-17:42 32.20 22.79 0.446833E+09 544.95 28-AUG-13:20 28.30 22.11
September 0.761137E+10 18259.41 03-SEP-15:32 29.80 23.28 0.396264E+09 544.98 22-SEP-13:39 26.50 17.31
October 0.652506E+10 19026.28 08-OCT-15:13 27.20 18.90 0.410981E+09 544.95 16-OCT-13:00 25.00 19.11
November 0.571114E+10 18739.24 11-NOV-15:53 21.70 11.60 0.405926E+09 544.98 16-NOV-10:09 10.68 10.03
December 0.500175E+10 15799.51 13-DEC-04:02 17.20 15.19 0.394709E+09 544.97 11-DEC-10:00 17.20 15.19
                     
Annual Sum or Average 0.950110E+11         0.487445E+10        
Minimum of Months 0.268835E+10 4634.21   10.00 3.54 0.355732E+09 544.94   10.68 9.28
Maximum of Months 0.148229E+11 21299.66   33.22 23.28 0.446833E+09 550.73   33.22 22.11



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_MID_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.648909E+09 2038.35 31-JAN-17:00 19.40 13.37 0.476543E+09 771.57 31-JAN-14:00 19.40 13.37
February 0.136411E+10 3558.94 28-FEB-15:00 25.00 13.71 0.458914E+09 845.61 28-FEB-14:09 25.00 13.71
March 0.317511E+10 5534.11 30-MAR-15:50 27.80 17.41 0.626167E+09 845.60 28-MAR-13:09 27.80 17.41
April 0.389276E+10 6119.35 19-APR-05:02 16.02 14.35 0.588554E+09 848.14 11-APR-13:09 16.02 14.35
May 0.584231E+10 9745.97 19-MAY-05:02 16.60 15.60 0.659494E+09 845.66 19-MAY-13:39 30.40 18.50
June 0.800433E+10 10900.18 26-JUN-05:02 23.30 21.67 0.662073E+09 846.56 02-JUN-13:39 23.30 21.67
July 0.835208E+10 10781.67 17-JUL-03:02 22.80 19.76 0.615845E+09 845.82 21-JUL-13:50 32.80 23.28
August 0.872268E+10 11212.61 04-AUG-03:02 24.82 22.98 0.691152E+09 845.61 10-AUG-13:39 30.77 23.76
September 0.545016E+10 9964.62 28-SEP-05:03 21.10 19.49 0.608802E+09 845.64 22-SEP-13:50 21.10 19.49
October 0.342505E+10 9702.37 19-OCT-05:02 20.92 20.92 0.589057E+09 845.61 05-OCT-13:09 20.92 20.92
November 0.230700E+10 3129.59 03-NOV-14:00 21.70 17.40 0.539746E+09 845.60 03-NOV-13:30 21.70 17.40
December 0.138897E+10 2622.04 13-DEC-06:02 16.70 15.65 0.480111E+09 845.55 13-DEC-14:00 18.30 16.86
                     
Annual Sum or Average 0.525735E+11         0.699646E+10        
Minimum of Months 0.648909E+09 2038.35   16.02 13.37 0.458914E+09 771.57   16.02 13.37
Maximum of Months 0.872268E+10 11212.61   27.80 22.98 0.691152E+09 848.14   32.80 23.76



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_MID_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.749990E+09 1605.71 31-JAN-16:50 19.50 13.40 0.228087E+09 478.73 31-JAN-16:00 19.40 13.37
February 0.136801E+10 4493.65 27-FEB-10:00 12.80 5.65 0.225275E+09 521.21 28-FEB-11:09 20.87 12.02
March 0.299453E+10 5431.13 14-MAR-10:10 18.27 14.61 0.306802E+09 521.30 20-MAR-08:00 8.30 3.51
April 0.415769E+10 11616.28 16-APR-09:23 21.65 14.38 0.285761E+09 523.48 12-APR-12:20 21.65 14.38
May 0.575933E+10 15376.59 07-MAY-08:53 23.30 19.24 0.313674E+09 533.62 15-MAY-15:00 28.90 17.26
June 0.730794E+10 15356.71 25-JUN-09:23 28.05 22.40 0.314187E+09 522.64 02-JUN-15:09 28.05 22.40
July 0.761695E+10 15352.80 02-JUL-10:13 26.47 22.31 0.293186E+09 521.69 07-JUL-10:00 32.20 24.14
August 0.773893E+10 15486.08 27-AUG-08:32 24.27 21.30 0.327841E+09 521.84 01-AUG-10:00 24.27 21.30
September 0.524465E+10 11462.83 24-SEP-09:23 24.70 18.53 0.288921E+09 521.28 11-SEP-08:00 24.70 18.53
October 0.330232E+10 6385.82 11-OCT-10:10 23.27 19.04 0.285344E+09 521.21 16-OCT-14:20 25.00 19.11
November 0.204080E+10 3914.93 06-NOV-09:40 13.67 11.97 0.265073E+09 521.21 02-NOV-10:20 13.67 11.97
December 0.134269E+10 2070.41 13-DEC-06:02 16.70 15.65 0.233809E+09 510.45 13-DEC-13:39 19.07 17.05
                     
Annual Sum or Average 0.496238E+11         0.336796E+10        
Minimum of Months 0.749990E+09 1605.71   12.80 5.65 0.225275E+09 478.73   8.30 3.51
Maximum of Months 0.773893E+10 15486.08   28.05 22.40 0.327841E+09 533.62   32.20 24.14



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_MID_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.258009E+10 9232.68 29-JAN-14:03 15.10 6.30 0.545708E+09 845.63 24-JAN-14:09 15.10 6.30
February 0.346163E+10 15730.06 26-FEB-12:43 23.72 12.50 0.511907E+09 863.56 21-FEB-14:39 23.72 12.50
March 0.571971E+10 12364.68 30-MAR-13:40 27.43 17.97 0.664116E+09 846.60 30-MAR-13:00 27.80 17.87
April 0.573574E+10 11340.11 17-APR-14:50 28.90 16.45 0.600886E+09 872.25 17-APR-13:00 28.90 16.45
May 0.676388E+10 11384.05 19-MAY-05:02 16.60 15.60 0.660532E+09 852.51 19-MAY-13:30 30.30 18.50
June 0.823048E+10 12600.40 26-JUN-05:02 23.30 21.67 0.661945E+09 848.23 02-JUN-13:39 23.30 21.67
July 0.877322E+10 12316.09 17-JUL-05:02 21.70 19.38 0.616170E+09 845.93 31-JUL-13:00 30.60 24.81
August 0.104745E+11 15719.92 13-AUG-16:51 31.10 22.45 0.692057E+09 858.38 25-AUG-13:00 31.10 18.60
September 0.810931E+10 15837.03 24-SEP-12:03 28.40 19.81 0.611831E+09 854.66 22-SEP-13:39 28.40 19.81
October 0.712000E+10 16950.48 09-OCT-14:22 27.50 19.51 0.619224E+09 893.36 10-OCT-13:50 29.22 21.00
November 0.524209E+10 16627.35 11-NOV-13:43 21.10 11.67 0.604378E+09 871.43 06-NOV-14:20 21.10 11.67
December 0.390322E+10 15538.89 10-DEC-14:53 18.30 8.64 0.559352E+09 849.16 19-DEC-10:50 6.73 1.51
                     
Annual Sum or Average 0.761138E+11         0.734811E+10        
Minimum of Months 0.258009E+10 9232.68   15.10 6.30 0.511907E+09 845.63   6.73 1.51
Maximum of Months 0.104745E+11 16950.48   31.10 22.45 0.692057E+09 893.36   31.10 24.81



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_MID_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.977862E+09 2015.37 20-JAN-16:30 16.95 12.13 0.317702E+09 521.16 20-JAN-16:49 16.78 11.69
February 0.161957E+10 6263.30 27-FEB-17:00 22.20 11.44 0.307215E+09 544.96 22-FEB-14:09 22.20 11.44
March 0.359400E+10 9886.81 30-MAR-05:02 17.80 16.10 0.416744E+09 544.95 13-MAR-13:00 17.80 16.10
April 0.456880E+10 14543.65 09-APR-16:52 21.70 10.78 0.386193E+09 547.09 11-APR-13:09 26.70 16.01
May 0.589981E+10 16555.12 21-MAY-17:02 26.52 19.80 0.426670E+09 546.83 15-MAY-15:00 26.52 19.80
June 0.741227E+10 16103.07 25-JUN-16:42 32.88 22.29 0.427459E+09 544.97 02-JUN-13:00 32.88 22.29
July 0.782073E+10 16685.26 02-JUL-18:12 29.83 21.48 0.397655E+09 544.95 05-JUL-09:20 28.87 23.62
August 0.840482E+10 17944.76 13-AUG-16:51 31.10 22.45 0.446390E+09 544.95 10-AUG-13:39 31.10 22.45
September 0.542008E+10 16100.02 04-SEP-16:33 28.13 22.40 0.393519E+09 544.97 22-SEP-13:50 26.60 17.45
October 0.359502E+10 14639.62 09-OCT-16:23 27.25 19.48 0.387858E+09 544.94 16-OCT-13:00 25.00 19.11
November 0.240241E+10 5962.62 06-NOV-16:00 20.60 10.48 0.363451E+09 544.94 03-NOV-13:30 20.60 10.48
December 0.162198E+10 3185.76 11-DEC-15:40 21.10 15.44 0.325758E+09 544.94 13-DEC-14:09 18.30 16.86
                     
Annual Sum or Average 0.533373E+11         0.459661E+10        
Minimum of Months 0.977862E+09 2015.37   16.95 10.48 0.307215E+09 521.16   16.78 10.48
Maximum of Months 0.840482E+10 17944.76   32.88 22.45 0.446390E+09 547.09   32.88 23.62



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_TOP_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.333101E+09 2035.64 20-JAN-16:40 16.87 11.91 0.468945E+09 751.58 20-JAN-14:00 16.87 11.91
February 0.890642E+09 2989.47 28-FEB-15:40 23.87 12.92 0.443423E+09 845.60 28-FEB-14:39 23.87 12.92
March 0.262832E+10 6245.04 30-MAR-15:50 27.80 17.41 0.589032E+09 845.60 28-MAR-13:09 27.80 17.41
April 0.364039E+10 6536.07 19-APR-14:30 26.15 17.54 0.569316E+09 845.64 12-APR-13:39 26.15 17.54
May 0.595698E+10 11259.01 19-MAY-05:02 16.60 15.60 0.654049E+09 845.64 15-MAY-13:09 16.60 15.60
June 0.861095E+10 13026.47 18-JUN-16:03 31.13 23.88 0.661611E+09 845.63 02-JUN-13:09 31.13 23.88
July 0.916109E+10 15153.30 02-JUL-18:12 29.83 21.48 0.615847E+09 845.60 17-JUL-13:09 29.40 22.24
August 0.950895E+10 15371.86 13-AUG-16:51 31.10 22.45 0.691425E+09 845.61 25-AUG-13:09 30.18 18.86
September 0.544835E+10 11363.00 27-SEP-05:03 22.80 20.09 0.602737E+09 845.62 15-SEP-13:30 22.80 20.09
October 0.286056E+10 9466.67 19-OCT-05:02 20.92 20.92 0.559609E+09 845.60 19-OCT-13:09 22.48 19.30
November 0.158308E+10 2712.77 03-NOV-15:40 21.30 17.04 0.500404E+09 845.60 03-NOV-13:00 21.30 17.04
December 0.666552E+09 2264.48 13-DEC-15:10 18.12 16.87 0.460126E+09 821.27 13-DEC-14:00 18.12 16.87
                     
Annual Sum or Average 0.512890E+11         0.681652E+10        
Minimum of Months 0.333101E+09 2035.64   16.60 11.91 0.443423E+09 751.58   16.60 11.91
Maximum of Months 0.950895E+10 15371.86   31.13 23.88 0.691425E+09 845.64   31.13 23.88



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_TOP_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.401738E+09 1561.33 20-JAN-16:40 16.87 11.91 0.303365E+09 476.21 31-JAN-14:00 21.10 12.97
February 0.971406E+09 3023.00 28-FEB-15:00 25.00 13.71 0.298500E+09 544.95 28-FEB-10:00 25.00 13.71
March 0.255716E+10 5122.67 30-MAR-11:00 22.20 17.83 0.405043E+09 544.99 08-MAR-10:09 22.20 17.83
April 0.397321E+10 9768.45 16-APR-11:13 26.47 15.53 0.384687E+09 544.98 12-APR-13:39 26.47 15.53
May 0.598725E+10 15766.00 07-MAY-09:43 24.72 19.90 0.425424E+09 545.19 30-MAY-09:00 27.80 21.16
June 0.795829E+10 15812.50 25-JUN-09:23 28.05 22.40 0.427352E+09 545.19 05-JUN-09:00 28.05 22.40
July 0.842636E+10 15829.49 02-JUL-10:13 26.47 22.31 0.397296E+09 545.62 17-JUL-09:50 27.52 21.93
August 0.852662E+10 15849.48 27-AUG-08:32 24.27 21.30 0.446051E+09 545.26 07-AUG-09:00 24.27 21.30
September 0.540146E+10 10801.39 07-SEP-05:02 22.20 21.11 0.390448E+09 545.32 08-SEP-09:00 27.20 22.45
October 0.289981E+10 6150.07 11-OCT-10:20 23.73 19.29 0.377866E+09 544.95 16-OCT-09:09 17.15 16.25
November 0.152902E+10 2460.62 06-NOV-10:50 16.73 12.97 0.336617E+09 544.94 03-NOV-13:39 16.73 12.97
December 0.761593E+09 1758.50 13-DEC-15:10 18.12 16.87 0.301643E+09 522.27 13-DEC-14:00 18.12 16.87
                     
Annual Sum or Average 0.493939E+11         0.449429E+10        
Minimum of Months 0.401738E+09 1561.33   16.73 11.91 0.298500E+09 476.21   16.73 12.97
Maximum of Months 0.852662E+10 15849.48   28.05 22.40 0.446051E+09 545.62   28.05 22.45



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_TOP_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.173640E+10 6630.73 11-JAN-14:40 6.70 2.05 0.523979E+09 845.96 23-JAN-14:39 9.80 3.43
February 0.258371E+10 15913.68 26-FEB-14:53 25.00 12.75 0.491877E+09 845.67 21-FEB-14:00 25.00 12.75
March 0.481315E+10 13022.00 30-MAR-13:50 27.62 17.92 0.636647E+09 845.72 30-MAR-13:00 27.80 17.87
April 0.539606E+10 14488.82 16-APR-13:53 28.90 16.19 0.586689E+09 858.21 17-APR-13:09 27.98 16.86
May 0.691313E+10 15323.54 29-MAY-15:32 29.80 20.59 0.655907E+09 858.73 19-MAY-13:50 29.80 20.59
June 0.887410E+10 14858.16 18-JUN-16:03 31.13 23.88 0.661135E+09 845.65 02-JUN-13:09 31.13 23.88
July 0.962848E+10 17154.00 02-JUL-18:12 29.83 21.48 0.616093E+09 845.87 14-JUL-13:20 34.07 24.24
August 0.113969E+11 18050.51 13-AUG-16:51 31.10 22.45 0.692256E+09 864.18 25-AUG-13:30 30.55 18.76
September 0.818382E+10 18471.12 24-SEP-14:23 28.60 20.22 0.607927E+09 847.86 22-SEP-13:00 28.60 20.22
October 0.627850E+10 18602.10 09-OCT-13:53 27.20 19.44 0.600503E+09 867.63 10-OCT-13:00 29.40 21.05
November 0.398099E+10 16275.35 11-NOV-14:12 21.10 11.73 0.570128E+09 845.78 07-NOV-14:50 21.10 11.73
December 0.262446E+10 9222.88 08-DEC-14:30 12.80 5.48 0.529214E+09 845.62 11-DEC-14:09 21.10 15.67
                     
Annual Sum or Average 0.724097E+11         0.717236E+10        
Minimum of Months 0.173640E+10 6630.73   6.70 2.05 0.491877E+09 845.62   9.80 3.43
Maximum of Months 0.113969E+11 18602.10   31.13 23.88 0.692256E+09 867.63   34.07 24.24



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_TOP_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.653486E+09 2024.58 20-JAN-16:40 16.87 11.91 0.308497E+09 512.58 20-JAN-16:49 16.78 11.69
February 0.126184E+10 5915.94 27-FEB-17:00 22.20 11.44 0.295161E+09 544.94 28-FEB-14:09 25.00 13.72
March 0.321911E+10 10541.48 31-MAR-05:02 16.78 15.18 0.393847E+09 544.94 27-MAR-13:00 16.78 15.18
April 0.442076E+10 12981.69 15-APR-17:05 26.42 15.32 0.375022E+09 544.98 12-APR-13:39 26.42 15.32
May 0.607950E+10 17199.16 29-MAY-15:32 29.80 20.59 0.423098E+09 547.73 16-MAY-15:00 29.80 20.59
June 0.793278E+10 18642.81 11-JUN-16:32 32.40 21.14 0.426914E+09 544.96 02-JUN-13:09 32.40 21.14
July 0.853577E+10 18168.59 02-JUL-18:12 29.83 21.48 0.397412E+09 544.94 17-JUL-13:09 29.40 22.24
August 0.910557E+10 19812.96 13-AUG-16:51 31.10 22.45 0.446389E+09 544.94 25-AUG-13:09 30.18 18.86
September 0.551288E+10 17402.89 04-SEP-16:42 28.22 22.25 0.389823E+09 544.95 15-SEP-13:30 28.05 18.25
October 0.327885E+10 9821.20 09-OCT-17:13 25.93 19.24 0.370470E+09 544.94 19-OCT-13:09 22.48 19.30
November 0.192469E+10 5518.71 06-NOV-16:00 20.60 10.48 0.338495E+09 544.94 03-NOV-13:00 20.60 10.48
December 0.109651E+10 2327.25 12-DEC-14:40 22.80 16.47 0.308730E+09 544.91 12-DEC-14:00 22.80 16.17
                     
Annual Sum or Average 0.530217E+11         0.447386E+10        
Minimum of Months 0.653486E+09 2024.58   16.78 10.48 0.295161E+09 512.58   16.78 10.48
Maximum of Months 0.910557E+10 19812.96   32.40 22.45 0.446389E+09 547.73   32.40 22.24



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: GROUNDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.590226E+09 3692.82 02-JAN-06:08 3.30 2.54 0.00 0.00 01-JAN-00:10 3.30 2.54
February 0.139940E+10 5107.41 28-FEB-06:15 10.97 5.96 0.00 0.00 01-FEB-00:10 10.97 5.96
March 0.395426E+10 5269.85 13-MAR-05:15 6.70 2.88 0.00 0.00 01-MAR-00:10 6.70 2.88
April 0.521784E+10 7251.29 17-APR-14:00 28.90 16.63 0.00 0.00 01-APR-00:10 28.90 16.63
May 0.603270E+10 7845.13 30-MAY-05:25 19.45 17.67 0.00 0.00 01-MAY-00:10 19.45 17.67
June 0.810728E+10 9395.53 19-JUN-05:15 20.93 20.12 0.00 0.00 01-JUN-00:10 20.93 20.12
July 0.911154E+10 13050.14 17-JUL-05:15 21.70 19.38 0.00 0.00 01-JUL-00:10 21.70 19.38
August 0.102194E+11 12436.74 07-AUG-05:15 23.13 22.40 0.00 0.00 01-AUG-00:10 23.13 22.40
September 0.654066E+10 10807.73 11-SEP-05:15 20.20 19.05 0.00 0.00 01-SEP-00:10 20.20 19.05
October 0.466492E+10 9941.55 10-OCT-05:15 15.73 14.81 0.00 0.00 01-OCT-00:10 15.73 14.81
November 0.323604E+10 7116.26 06-NOV-06:15 9.23 8.65 0.00 0.00 01-NOV-00:10 9.23 8.65
December 0.184349E+10 4119.48 13-DEC-06:15 16.70 15.65 0.00 0.00 01-DEC-00:10 16.70 15.65
                     
Annual Sum or Average 0.609177E+11         0.00        
Minimum of Months 0.590226E+09 3692.82   3.30 2.54 0.00 0.00   3.30 2.54
Maximum of Months 0.102194E+11 13050.14   28.90 22.40 0.00 0.00   28.90 22.40



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: MIDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.140575E+09 3716.30 09-JAN-04:01 -1.8 -2.4 0.00 0.00 01-JAN-00:10 -1.8 -2.4
February 0.492201E+09 4277.65 03-FEB-05:01 -7.9 -9.5 0.00 0.00 01-FEB-00:10 -7.9 -9.5
March 0.186711E+10 3690.30 15-MAR-05:10 8.22 4.19 0.00 0.00 01-MAR-00:10 8.22 4.19
April 0.309585E+10 5485.66 17-APR-15:30 28.90 16.41 0.00 0.00 01-APR-00:10 28.90 16.41
May 0.461371E+10 6768.45 30-MAY-05:02 18.68 17.36 0.00 0.00 01-MAY-00:10 18.68 17.36
June 0.640100E+10 7457.02 15-JUN-05:02 22.20 18.53 0.00 0.00 01-JUN-00:10 22.20 18.53
July 0.689599E+10 6820.57 01-JUL-05:15 21.87 20.54 0.00 0.00 01-JUL-00:10 21.87 20.54
August 0.749244E+10 7770.16 11-AUG-05:03 22.80 22.07 0.00 0.00 01-AUG-00:10 22.80 22.07
September 0.500491E+10 6937.05 11-SEP-05:02 20.40 19.24 0.00 0.00 01-SEP-00:10 20.40 19.24
October 0.264817E+10 4391.37 11-OCT-05:15 18.53 16.62 0.00 0.00 01-OCT-00:10 18.53 16.62
November 0.114165E+10 4624.88 21-NOV-06:01 -2.8 -3.9 0.00 0.00 01-NOV-00:10 -2.8 -3.9
December 0.561296E+09 4352.96 01-DEC-06:01 -3.9 -4.8 0.00 0.00 01-DEC-00:10 -3.9 -4.8
                     
Annual Sum or Average 0.403549E+11         0.00        
Minimum of Months 0.140575E+09 3690.30   -7.9 -9.5 0.00 0.00   -7.9 -9.5
Maximum of Months 0.749244E+10 7770.16   28.90 22.07 0.00 0.00   28.90 22.07



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: TOPFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 45881411.19 1382.41 31-JAN-13:10 19.60 13.60 0.00 0.00 01-JAN-00:10 19.60 13.60
February 0.515924E+09 5659.70 28-FEB-16:00 23.30 12.53 0.00 0.00 01-FEB-00:10 23.30 12.53
March 0.233836E+10 12720.67 30-MAR-15:30 27.80 17.27 0.00 0.00 01-MAR-00:10 27.80 17.27
April 0.491356E+10 17321.53 17-APR-15:00 28.90 16.41 0.00 0.00 01-APR-00:10 28.90 16.41
May 0.836817E+10 17626.10 19-MAY-13:35 30.40 18.50 0.00 0.00 01-MAY-00:10 30.40 18.50
June 0.119766E+11 17453.75 13-JUN-13:50 33.80 22.33 0.00 0.00 01-JUN-00:10 33.80 22.33
July 0.127457E+11 19506.40 07-JUL-15:10 35.10 23.86 0.00 0.00 01-JUL-00:10 35.10 23.86
August 0.133098E+11 18229.44 01-AUG-14:20 34.27 23.72 0.00 0.00 01-AUG-00:10 34.27 23.72
September 0.701048E+10 14891.74 06-SEP-14:50 29.68 22.88 0.00 0.00 01-SEP-00:10 29.68 22.88
October 0.299673E+10 10450.82 10-OCT-15:20 29.27 20.62 0.00 0.00 01-OCT-00:10 29.27 20.62
November 0.743262E+09 4404.87 05-NOV-14:30 23.60 18.49 0.00 0.00 01-NOV-00:10 23.60 18.49
December 0.105248E+09 2119.04 12-DEC-13:10 21.38 16.69 0.00 0.00 01-DEC-00:10 21.38 16.69
                     
Annual Sum or Average 0.650696E+11         0.00        
Minimum of Months 45881411.19 1382.41   19.60 12.53 0.00 0.00   19.60 12.53
Maximum of Months 0.133098E+11 19506.40   35.10 23.86 0.00 0.00   35.10 23.86



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: DATACENTER_BOT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.281110E+10 1739.54 23-JAN-17:00 10.00 3.54 95230839.70 126.84 20-JAN-10:00 10.00 3.54
February 0.769934E+10 3909.31 20-FEB-17:50 17.38 9.48 86397299.03 126.84 17-FEB-14:00 17.38 9.48
March 0.143063E+11 7149.51 31-MAR-24:00 12.10 7.93 0.103239E+09 126.84 31-MAR-09:00 12.10 7.93
April 0.188072E+11 7854.47 09-APR-18:23 19.15 10.75 91606460.19 126.83 03-APR-09:39 19.15 10.75
May 0.438743E+10 3458.30 31-MAY-24:00 21.00 18.72 99239586.62 126.85 22-MAY-13:00 21.00 18.72
June 0.925333E+10 5329.73 30-JUN-24:00 22.30 21.46 98975385.10 126.86 26-JUN-09:00 22.30 21.46
July 0.146485E+11 7233.00 31-JUL-23:57 25.20 21.98 91893821.53 126.85 26-JUL-09:09 25.20 21.98
August 0.196807E+11 7858.10 13-AUG-18:40 30.37 21.91 0.103478E+09 129.20 02-AUG-13:00 30.37 21.91
September 0.432810E+10 3244.74 30-SEP-24:00 16.80 15.75 91610533.68 126.85 25-SEP-09:00 16.80 15.75
October 0.934656E+10 5155.81 31-OCT-24:00 9.70 6.26 95238551.89 126.86 18-OCT-13:00 9.70 6.26
November 0.137940E+11 5820.53 11-NOV-16:55 19.40 10.60 94302255.92 126.84 27-NOV-14:00 22.20 17.55
December 0.190688E+11 7561.67 10-DEC-17:00 17.20 8.59 91881438.61 126.83 13-DEC-14:30 18.30 16.86
                     
Annual Sum or Average 0.138131E+12         0.114309E+10        
Minimum of Months 0.281110E+10 1739.54   9.70 3.54 86397299.03 126.83   9.70 3.54
Maximum of Months 0.196807E+11 7858.10   30.37 21.98 0.103478E+09 129.20   30.37 21.98



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: DATACENTER_MID_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.728679E+09 1395.33 26-JAN-17:00 2.20 -2.8 94931609.36 126.83 20-JAN-14:00 2.20 -2.8
February 0.575232E+10 3514.92 24-FEB-17:50 15.18 6.70 86397260.74 126.84 17-FEB-14:00 15.18 6.70
March 0.128955E+11 6720.55 31-MAR-24:00 12.10 7.93 0.103239E+09 126.84 31-MAR-09:00 12.10 7.93
April 0.176720E+11 7303.13 09-APR-18:27 19.15 10.75 91606377.77 126.83 03-APR-09:50 19.15 10.75
May 0.392709E+10 3266.89 31-MAY-24:00 21.00 18.72 99237603.35 126.84 04-MAY-13:09 21.00 18.72
June 0.873293E+10 5108.79 30-JUN-24:00 22.30 21.46 98974330.78 126.86 23-JUN-09:00 22.30 21.46
July 0.139227E+11 6984.12 31-JUL-23:57 25.20 21.98 91892973.17 126.85 26-JUL-09:09 25.20 21.98
August 0.187717E+11 7398.44 13-AUG-18:40 30.37 21.91 0.103653E+09 130.68 02-AUG-13:00 30.37 21.91
September 0.381053E+10 2774.88 30-SEP-24:00 16.80 15.75 91609105.30 126.84 18-SEP-13:00 16.80 15.75
October 0.814021E+10 4482.49 31-OCT-24:00 9.70 6.26 95237957.36 126.86 18-OCT-13:39 9.70 6.26
November 0.119749E+11 5391.13 06-NOV-17:00 18.90 9.61 94302073.71 126.84 27-NOV-10:00 19.40 16.85
December 0.161914E+11 6994.97 08-DEC-17:00 11.10 4.72 91881443.97 126.83 13-DEC-14:20 18.30 16.86
                     
Annual Sum or Average 0.122520E+12         0.114296E+10        
Minimum of Months 0.728679E+09 1395.33   2.20 -2.8 86397260.74 126.83   2.20 -2.8
Maximum of Months 0.187717E+11 7398.44   30.37 21.98 0.103653E+09 130.68   30.37 21.98



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: DATACENTER_TOP_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.244052E+09 1324.89 20-JAN-17:00 16.70 11.48 91254093.58 128.16 23-JAN-14:20 9.60 3.21
February 0.437769E+10 3501.14 28-FEB-17:00 23.90 12.94 86397282.05 126.84 17-FEB-14:00 23.90 12.94
March 0.120121E+11 6485.82 31-MAR-23:30 12.20 7.91 0.103239E+09 126.84 31-MAR-09:00 12.20 7.91
April 0.172751E+11 7355.06 09-APR-18:16 19.80 10.92 91606534.27 126.83 04-APR-09:50 19.80 10.92
May 0.386319E+10 3233.58 31-MAY-24:00 21.00 18.72 99237993.65 126.85 04-MAY-13:39 21.00 18.72
June 0.880673E+10 5093.05 30-JUN-24:00 22.30 21.46 98975159.30 126.86 26-JUN-13:00 22.30 21.46
July 0.140219E+11 7025.16 31-JUL-23:57 25.20 21.98 91893653.32 126.85 26-JUL-09:09 25.20 21.98
August 0.188751E+11 7648.82 13-AUG-19:10 29.90 21.88 0.103558E+09 130.25 01-AUG-13:00 29.90 21.88
September 0.367978E+10 2306.31 30-SEP-24:00 16.80 15.75 91608914.50 126.84 25-SEP-13:09 16.80 15.75
October 0.734053E+10 3953.36 31-OCT-23:30 9.65 5.98 95237980.58 126.86 18-OCT-13:00 9.65 5.98
November 0.105838E+11 5369.06 06-NOV-17:00 18.90 9.61 94302119.21 126.84 27-NOV-10:00 19.40 16.85
December 0.142437E+11 6841.67 13-DEC-16:30 16.95 16.79 91881522.66 126.83 13-DEC-10:09 16.95 16.79
                     
Annual Sum or Average 0.115324E+12         0.113919E+10        
Minimum of Months 0.244052E+09 1324.89   9.65 5.98 86397282.05 126.83   9.60 3.21
Maximum of Months 0.188751E+11 7648.82   29.90 21.98 0.103558E+09 130.25   29.90 21.98



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: DATACENTER_BASEMENT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.234340E+12 90170.26 02-JAN-17:00 8.30 5.05 0.206144E+10 2745.29 03-JAN-10:09 1.70 1.25
February 0.431856E+12 181752.05 21-FEB-17:00 21.70 10.37 0.187022E+10 2745.29 02-FEB-10:00 21.70 10.37
March 0.724712E+12 357204.03 31-MAR-24:00 12.10 7.93 0.223475E+10 2745.29 09-MAR-10:30 12.10 7.93
April 0.936785E+12 364243.34 17-APR-15:55 28.90 16.41 0.198297E+10 2745.29 06-APR-13:09 28.90 16.41
May 0.237294E+12 174536.61 31-MAY-24:00 21.00 18.72 0.214810E+10 2745.29 12-MAY-09:00 21.00 18.72
June 0.467224E+12 266538.74 30-JUN-24:00 22.30 21.46 0.214213E+10 2745.29 01-JUN-13:20 22.30 21.46
July 0.729190E+12 358893.96 31-JUL-23:53 25.20 21.98 0.198894E+10 2745.29 24-JUL-09:09 25.20 21.98
August 0.975426E+12 366909.35 07-AUG-16:00 31.70 25.05 0.223475E+10 2745.29 08-AUG-13:09 31.60 24.22
September 0.234792E+12 175371.16 30-SEP-24:00 16.80 15.75 0.198297E+10 2745.29 12-SEP-13:20 16.80 15.75
October 0.486126E+12 267538.44 31-OCT-24:00 9.70 6.26 0.206144E+10 2745.29 11-OCT-09:09 9.70 6.26
November 0.707244E+12 275646.64 06-NOV-17:00 18.90 9.61 0.204131E+10 2745.29 30-NOV-10:09 5.68 5.68
December 0.973873E+12 366485.48 11-DEC-17:00 20.60 15.75 0.198894E+10 2745.29 06-DEC-14:20 20.60 15.75
                     
Annual Sum or Average 0.713886E+13         0.247380E+11        
Minimum of Months 0.234340E+12 90170.26   8.30 5.05 0.187022E+10 2745.29   1.70 1.25
Maximum of Months 0.975426E+12 366909.35   31.70 25.05 0.223475E+10 2745.29   31.60 24.22



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: BASEMENT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.381981E+09 9642.99 20-JAN-05:17 12.80
February 0.115944E+09 9990.35 27-FEB-04:07 11.20
March 0.201622E+09 10035.55 13-MAR-03:07 7.70
April 0.300298E+09 10745.20 15-APR-15:02 27.88
May 0.324039E+09 12073.56 06-MAY-16:03 29.63
June 0.373448E+09 15650.81 24-JUN-15:02 32.88
July 0.456938E+09 19397.22 08-JUL-15:02 36.70
August 0.475624E+09 15844.44 19-AUG-15:02 33.22
September 0.627728E+09 12079.68 04-SEP-14:03 26.47
October 0.619454E+09 11978.54 09-OCT-11:03 24.32
November 0.548180E+09 11540.57 12-NOV-15:32 19.60
December 0.392145E+09 9808.45 27-DEC-04:05 2.20
         
Annual Sum or Average 0.481740E+10      
Minimum of Months 0.115944E+09 9642.99   2.20
Maximum of Months 0.627728E+09 19397.22   36.70



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: CORE_BOTTOM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:10 5.70
February 0.00 0.00 01-FEB-00:10 9.92
March 0.00 0.00 01-MAR-00:10 15.32
April 0.00 0.00 01-APR-00:10 12.05
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 0.00 0.00 01-OCT-00:10 16.85
November 0.00 0.00 01-NOV-00:10 9.70
December 0.00 0.00 01-DEC-00:10 1.80
         
Annual Sum or Average 0.00      
Minimum of Months 0.00 0.00   1.80
Maximum of Months 0.00 0.00   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: CORE_MID

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 24334022.38 32495.26 09-JAN-06:01 -2.4
February 2702361.53 31527.55 13-FEB-06:01 -5.6
March 0.00 0.00 01-MAR-00:10 15.32
April 0.00 0.00 01-APR-00:10 12.05
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 0.00 0.00 01-OCT-00:10 16.85
November 0.00 0.00 01-NOV-00:10 9.70
December 0.00 0.00 01-DEC-00:10 1.80
         
Annual Sum or Average 27036383.91      
Minimum of Months 0.00 0.00   -5.6
Maximum of Months 24334022.38 32495.26   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: CORE_TOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.376884E+10 70484.51 09-JAN-04:01 -1.8
February 0.163976E+10 69175.31 13-FEB-04:01 -5.0
March 9531891.30 42033.69 20-MAR-05:03 5.00
April 0.00 0.00 01-APR-00:10 12.05
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 9985189.34 44419.25 30-OCT-05:03 8.90
November 0.124662E+09 57840.47 22-NOV-06:01 -3.3
December 0.150852E+10 66764.48 04-DEC-04:01 -2.3
         
Annual Sum or Average 0.706130E+10      
Minimum of Months 0.00 0.00   -5.0
Maximum of Months 0.376884E+10 70484.51   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_BOT_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 96116907.50 9629.10 10-JAN-06:01 -4.4
February 34049218.62 9718.92 13-FEB-06:01 -5.6
March 0.00 0.00 01-MAR-00:10 15.32
April 0.00 0.00 01-APR-00:10 12.05
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 0.00 0.00 01-OCT-00:10 16.85
November 0.00 0.00 01-NOV-00:10 9.70
December 0.00 0.00 01-DEC-00:10 1.80
         
Annual Sum or Average 0.130166E+09      
Minimum of Months 0.00 0.00   -5.6
Maximum of Months 96116907.50 9718.92   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_BOT_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 74889333.72 7518.07 10-JAN-06:01 -4.4
February 22270908.25 7531.86 13-FEB-06:01 -5.6
March 0.00 0.00 01-MAR-00:10 15.32
April 0.00 0.00 01-APR-00:10 12.05
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 0.00 0.00 01-OCT-00:10 16.85
November 0.00 0.00 01-NOV-00:10 9.70
December 36197.98 172.50 01-DEC-06:03 -3.9
         
Annual Sum or Average 97196439.96      
Minimum of Months 0.00 0.00   -5.6
Maximum of Months 74889333.72 7531.86   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_BOT_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.139057E+09 12134.76 09-JAN-05:01 -2.2
February 45075023.33 11634.14 13-FEB-05:01 -5.1
March 0.00 0.00 01-MAR-00:10 15.32
April 0.00 0.00 01-APR-00:10 12.05
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 0.00 0.00 01-OCT-00:10 16.85
November 0.00 0.00 01-NOV-00:10 9.70
December 1614777.68 6682.61 26-DEC-06:01 3.30
         
Annual Sum or Average 0.185747E+09      
Minimum of Months 0.00 0.00   -5.1
Maximum of Months 0.139057E+09 12134.76   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_BOT_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 2130613.01 5275.06 09-JAN-06:01 -2.4
February 0.00 0.00 01-FEB-00:10 9.92
March 0.00 0.00 01-MAR-00:10 15.32
April 0.00 0.00 01-APR-00:10 12.05
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 0.00 0.00 01-OCT-00:10 16.85
November 0.00 0.00 01-NOV-00:10 9.70
December 0.00 0.00 01-DEC-00:10 1.80
         
Annual Sum or Average 2130613.01      
Minimum of Months 0.00 0.00   -2.4
Maximum of Months 2130613.01 5275.06   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_MID_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.211569E+10 11544.37 09-JAN-04:01 -1.8
February 0.937265E+09 11558.59 13-FEB-04:01 -5.0
March 7225040.49 5264.25 23-MAR-05:03 6.10
April 17583.07 117.22 07-APR-05:05 3.22
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 4954728.29 6245.53 26-OCT-05:03 2.20
November 95704350.65 9938.99 22-NOV-05:01 -2.9
December 0.650197E+09 10648.78 04-DEC-05:01 -2.8
         
Annual Sum or Average 0.381106E+10      
Minimum of Months 0.00 0.00   -5.0
Maximum of Months 0.211569E+10 11558.59   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_MID_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.108448E+10 12650.06 09-JAN-04:01 -1.8
February 0.423489E+09 12375.93 13-FEB-04:01 -5.0
March 3646925.13 4896.17 23-MAR-05:03 6.10
April 28221.63 188.14 06-APR-05:05 0.18
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 2539792.31 3138.71 26-OCT-05:03 2.20
November 33684192.39 10662.54 22-NOV-05:01 -2.9
December 0.285614E+09 11482.07 04-DEC-05:01 -2.8
         
Annual Sum or Average 0.183349E+10      
Minimum of Months 0.00 0.00   -5.0
Maximum of Months 0.108448E+10 12650.06   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_MID_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.875456E+09 13078.56 09-JAN-04:01 -1.8
February 0.330289E+09 12031.25 13-FEB-05:01 -5.1
March 1349594.91 2835.85 23-MAR-05:03 6.10
April 0.00 0.00 01-APR-00:10 12.05
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 0.00 0.00 01-OCT-00:10 16.85
November 22150598.49 10864.33 21-NOV-06:01 -2.8
December 0.179210E+09 11703.86 26-DEC-05:01 3.80
         
Annual Sum or Average 0.140845E+10      
Minimum of Months 0.00 0.00   -5.1
Maximum of Months 0.875456E+09 13078.56   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_MID_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.734326E+09 12445.16 09-JAN-04:01 -1.8
February 0.281374E+09 11672.63 13-FEB-05:01 -5.1
March 18982.40 126.55 23-MAR-05:05 6.10
April 0.00 0.00 01-APR-00:10 12.05
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 0.00 0.00 01-OCT-00:10 16.85
November 30181616.68 10409.98 22-NOV-06:01 -3.3
December 0.167270E+09 11102.75 18-DEC-05:01 -5.0
         
Annual Sum or Average 0.121317E+10      
Minimum of Months 0.00 0.00   -5.1
Maximum of Months 0.734326E+09 12445.16   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_TOP_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.589730E+10 13658.24 09-JAN-04:01 -1.8
February 0.319374E+10 14044.20 12-FEB-05:53 -12.2
March 0.342918E+09 11608.86 20-MAR-04:02 6.42
April 87919482.82 10889.23 07-APR-04:03 3.80
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 0.160402E+09 11450.19 26-OCT-04:02 2.70
November 0.993640E+09 12603.57 22-NOV-04:02 -2.8
December 0.309486E+10 13476.66 26-DEC-04:01 3.90
         
Annual Sum or Average 0.137708E+11      
Minimum of Months 0.00 0.00   -12.2
Maximum of Months 0.589730E+10 14044.20   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_TOP_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.300645E+10 13431.92 09-JAN-04:01 -1.8
February 0.153863E+10 13656.38 12-FEB-05:53 -12.2
March 0.139630E+09 11374.98 23-MAR-04:02 5.18
April 28114274.15 9177.96 06-APR-05:03 0.18
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 89573846.57 11079.61 26-OCT-04:02 2.70
November 0.386354E+09 12111.78 22-NOV-04:02 -2.8
December 0.141719E+10 13268.71 26-DEC-04:01 3.90
         
Annual Sum or Average 0.660594E+10      
Minimum of Months 0.00 0.00   -12.2
Maximum of Months 0.300645E+10 13656.38   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_TOP_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.302667E+10 15502.71 09-JAN-04:01 -1.8
February 0.158205E+10 15778.82 12-FEB-05:53 -12.2
March 0.135302E+09 13032.24 23-MAR-04:02 5.18
April 43978072.70 12033.87 06-APR-05:03 0.18
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 98463520.91 12373.71 31-OCT-04:03 8.80
November 0.336256E+09 13567.97 21-NOV-05:01 -2.3
December 0.131916E+10 15283.88 26-DEC-04:01 3.90
         
Annual Sum or Average 0.654187E+10      
Minimum of Months 0.00 0.00   -12.2
Maximum of Months 0.302667E+10 15778.82   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_TOP_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.245554E+10 14913.49 09-JAN-04:01 -1.8
February 0.112541E+10 14425.17 12-FEB-07:53 -12.2
March 53465365.27 9567.08 23-MAR-04:02 5.18
April 14371916.57 8694.00 06-APR-05:03 0.18
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 41298245.14 10631.25 31-OCT-05:02 8.30
November 0.290899E+09 13073.74 22-NOV-05:01 -2.9
December 0.101099E+10 14372.34 18-DEC-04:01 -4.1
         
Annual Sum or Average 0.499198E+10      
Minimum of Months 0.00 0.00   -12.2
Maximum of Months 0.245554E+10 14913.49   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: GROUNDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.669155E+09 9343.97 17-JAN-06:02 4.72
February 0.390777E+09 9973.39 14-FEB-06:01 1.10
March 88054500.47 7970.03 24-MAR-04:03 11.20
April 0.105402E+09 8378.67 04-APR-03:02 15.10
May 49514094.24 5264.41 01-MAY-03:02 16.27
June 52702071.38 5413.37 16-JUN-03:02 21.02
July 59235564.89 6913.28 29-JUL-03:02 17.70
August 37915250.25 5618.07 06-AUG-16:21 32.50
September 54269349.93 5894.06 16-SEP-03:02 22.70
October 79248593.96 9682.99 02-OCT-03:02 19.82
November 0.103635E+09 10066.26 27-NOV-04:02 14.50
December 85587153.70 11114.26 26-DEC-04:01 3.90
         
Annual Sum or Average 0.177550E+10      
Minimum of Months 37915250.25 5264.41   1.10
Maximum of Months 0.669155E+09 11114.26   32.50



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: MIDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.225981E+10 4963.22 09-JAN-06:08 -2.4
February 0.110995E+10 4913.44 22-FEB-06:03 12.02
March 0.100835E+09 5321.22 22-MAR-05:03 6.02
April 32707542.74 4985.14 03-APR-04:03 20.22
May 35670579.53 4620.57 01-MAY-04:03 16.10
June 27694285.26 4943.00 14-JUN-03:02 22.62
July 32923697.63 4748.63 14-JUL-03:02 23.22
August 29067995.77 5086.82 04-AUG-03:02 24.82
September 31352193.68 4509.81 05-SEP-03:02 22.02
October 89125221.30 4905.41 25-OCT-05:02 9.90
November 0.230621E+09 5636.81 01-NOV-05:02 10.00
December 0.102053E+10 5524.42 13-DEC-06:02 16.70
         
Annual Sum or Average 0.500028E+10      
Minimum of Months 27694285.26 4509.81   -2.4
Maximum of Months 0.225981E+10 5636.81   24.82



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: TOPFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.817894E+10 21021.78 09-JAN-05:33 -2.2
February 0.497361E+10 22086.30 13-FEB-05:22 -5.3
March 0.155584E+10 11404.81 14-MAR-05:02 13.30
April 0.801160E+09 13331.66 11-APR-05:02 11.10
May 0.236255E+09 12690.13 12-MAY-05:03 11.60
June 0.112505E+09 12906.02 08-JUN-05:03 11.70
July 45763330.17 9322.35 03-JUL-03:02 17.80
August 39555254.13 8218.61 28-AUG-03:02 21.60
September 0.213378E+09 12366.44 14-SEP-05:02 12.20
October 0.122667E+10 13637.95 12-OCT-05:03 9.22
November 0.244044E+10 14148.43 22-NOV-06:13 -3.3
December 0.501780E+10 20396.32 18-DEC-06:15 -5.0
         
Annual Sum or Average 0.248419E+11      
Minimum of Months 39555254.13 8218.61   -5.3
Maximum of Months 0.817894E+10 22086.30   21.60



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: DATACENTER_BOT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:10 5.70
February 0.00 0.00 01-FEB-00:10 9.92
March 0.00 0.00 01-MAR-00:10 15.32
April 0.00 0.00 01-APR-00:10 12.05
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 0.00 0.00 01-OCT-00:10 16.85
November 0.00 0.00 01-NOV-00:10 9.70
December 0.00 0.00 01-DEC-00:10 1.80
         
Annual Sum or Average 0.00      
Minimum of Months 0.00 0.00   1.80
Maximum of Months 0.00 0.00   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: DATACENTER_MID_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.229377E+09 514.85 08-JAN-19:10 -0.6
February 0.00 0.00 01-FEB-00:10 9.92
March 0.00 0.00 01-MAR-00:10 15.32
April 0.00 0.00 01-APR-00:10 12.05
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 0.00 0.00 01-OCT-00:10 16.85
November 0.00 0.00 01-NOV-00:10 9.70
December 0.00 0.00 01-DEC-00:10 1.80
         
Annual Sum or Average 0.229377E+09      
Minimum of Months 0.00 0.00   -0.6
Maximum of Months 0.229377E+09 514.85   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: DATACENTER_TOP_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.686221E+09 565.76 22-JAN-18:50 1.38
February 35335809.59 519.86 13-FEB-03:40 -4.6
March 0.00 0.00 01-MAR-00:10 15.32
April 0.00 0.00 01-APR-00:10 12.05
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 0.00 0.00 01-OCT-00:10 16.85
November 0.00 0.00 01-NOV-00:10 9.70
December 0.00 0.00 01-DEC-00:10 1.80
         
Annual Sum or Average 0.721557E+09      
Minimum of Months 0.00 0.00   -4.6
Maximum of Months 0.686221E+09 565.76   25.13



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: DATACENTER_BASEMENT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:10 5.70
February 0.00 0.00 01-FEB-00:10 9.92
March 0.00 0.00 01-MAR-00:10 15.32
April 0.00 0.00 01-APR-00:10 12.05
May 0.00 0.00 01-MAY-00:03 16.68
June 0.00 0.00 01-JUN-00:10 20.93
July 0.00 0.00 01-JUL-00:10 22.28
August 0.00 0.00 01-AUG-00:05 25.13
September 0.00 0.00 01-SEP-00:10 21.40
October 0.00 0.00 01-OCT-00:10 16.85
November 0.00 0.00 01-NOV-00:10 9.70
December 0.00 0.00 01-DEC-00:10 1.80
         
Annual Sum or Average 0.00      
Minimum of Months 0.00 0.00   1.80
Maximum of Months 0.00 0.00   25.13



Table of Contents

Report: ZoneElectricSummaryMonthly

For: BASEMENT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.113123E+11 11837.83 02-JAN-08:09 0.360447E+11 13457.54 01-JAN-00:10
February 0.102611E+11 11837.83 01-FEB-08:09 0.325565E+11 13457.54 01-FEB-00:10
March 0.121930E+11 11837.83 01-MAR-08:09 0.360447E+11 13457.54 01-MAR-00:10
April 0.108909E+11 11837.83 03-APR-07:10 0.348820E+11 13457.54 01-APR-00:10
May 0.117527E+11 11837.83 01-MAY-07:10 0.360447E+11 13457.54 01-MAY-00:10
June 0.116958E+11 11837.83 01-JUN-07:10 0.348820E+11 13457.54 01-JUN-00:10
July 0.109477E+11 11837.83 03-JUL-07:10 0.360447E+11 13457.54 01-JUL-00:10
August 0.121930E+11 11837.83 01-AUG-07:10 0.360447E+11 13457.54 01-AUG-00:10
September 0.108909E+11 11837.83 01-SEP-07:10 0.348820E+11 13457.54 01-SEP-00:10
October 0.113123E+11 11837.83 02-OCT-07:10 0.360447E+11 13457.54 01-OCT-00:10
November 0.111797E+11 11837.83 01-NOV-07:10 0.348820E+11 13457.54 01-NOV-00:10
December 0.109477E+11 11837.83 01-DEC-08:09 0.360447E+11 13457.54 01-DEC-00:10
             
Annual Sum or Average 0.135577E+12     0.424397E+12    
Minimum of Months 0.102611E+11 11837.83   0.325565E+11 13457.54  
Maximum of Months 0.121930E+11 11837.83   0.360447E+11 13457.54  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: CORE_BOTTOM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.101592E+11 10631.20 02-JAN-08:09 0.243681E+11 17206.63 02-JAN-08:09
February 0.921518E+10 10631.20 01-FEB-08:09 0.220609E+11 17206.63 01-FEB-08:09
March 0.109502E+11 10631.20 01-MAR-08:09 0.253549E+11 17206.63 01-MAR-08:09
April 0.978077E+10 10631.20 03-APR-07:10 0.235306E+11 17206.63 03-APR-07:10
May 0.105547E+11 10631.20 01-MAY-07:10 0.248615E+11 17206.63 01-MAY-07:10
June 0.105037E+11 10631.20 01-JUN-07:10 0.244160E+11 17206.63 01-JUN-07:10
July 0.983180E+10 10631.20 03-JUL-07:10 0.239708E+11 17206.63 03-JUL-07:10
August 0.109502E+11 10631.20 01-AUG-07:10 0.253549E+11 17206.63 01-AUG-07:10
September 0.978077E+10 10631.20 01-SEP-07:10 0.235199E+11 17206.63 01-SEP-07:10
October 0.101592E+11 10631.20 02-OCT-07:10 0.243735E+11 17206.63 02-OCT-07:10
November 0.100402E+11 10631.20 01-NOV-07:10 0.238373E+11 17206.63 01-NOV-07:10
December 0.983180E+10 10631.20 01-DEC-08:09 0.239654E+11 17206.63 01-DEC-08:09
             
Annual Sum or Average 0.121758E+12     0.289614E+12    
Minimum of Months 0.921518E+10 10631.20   0.220609E+11 17206.63  
Maximum of Months 0.109502E+11 10631.20   0.253549E+11 17206.63  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: CORE_MID

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.101592E+11 10631.20 02-JAN-08:09 0.243680E+11 17206.56 02-JAN-08:09
February 0.921518E+10 10631.20 01-FEB-08:09 0.220609E+11 17206.56 01-FEB-08:09
March 0.109502E+11 10631.20 01-MAR-08:09 0.253548E+11 17206.56 01-MAR-08:09
April 0.978077E+10 10631.20 03-APR-07:10 0.235305E+11 17206.56 03-APR-07:10
May 0.105547E+11 10631.20 01-MAY-07:10 0.248614E+11 17206.56 01-MAY-07:10
June 0.105037E+11 10631.20 01-JUN-07:10 0.244159E+11 17206.56 01-JUN-07:10
July 0.983180E+10 10631.20 03-JUL-07:10 0.239707E+11 17206.56 03-JUL-07:10
August 0.109502E+11 10631.20 01-AUG-07:10 0.253548E+11 17206.56 01-AUG-07:10
September 0.978077E+10 10631.20 01-SEP-07:10 0.235198E+11 17206.56 01-SEP-07:10
October 0.101592E+11 10631.20 02-OCT-07:10 0.243734E+11 17206.56 02-OCT-07:10
November 0.100402E+11 10631.20 01-NOV-07:10 0.238372E+11 17206.56 01-NOV-07:10
December 0.983180E+10 10631.20 01-DEC-08:09 0.239653E+11 17206.56 01-DEC-08:09
             
Annual Sum or Average 0.121758E+12     0.289613E+12    
Minimum of Months 0.921518E+10 10631.20   0.220609E+11 17206.56  
Maximum of Months 0.109502E+11 10631.20   0.253548E+11 17206.56  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: CORE_TOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.101592E+11 10631.20 02-JAN-08:09 0.243680E+11 17206.56 02-JAN-08:09
February 0.921518E+10 10631.20 01-FEB-08:09 0.220609E+11 17206.56 01-FEB-08:09
March 0.109502E+11 10631.20 01-MAR-08:09 0.253548E+11 17206.56 01-MAR-08:09
April 0.978077E+10 10631.20 03-APR-07:10 0.235305E+11 17206.56 03-APR-07:10
May 0.105547E+11 10631.20 01-MAY-07:10 0.248614E+11 17206.56 01-MAY-07:10
June 0.105037E+11 10631.20 01-JUN-07:10 0.244159E+11 17206.56 01-JUN-07:10
July 0.983180E+10 10631.20 03-JUL-07:10 0.239707E+11 17206.56 03-JUL-07:10
August 0.109502E+11 10631.20 01-AUG-07:10 0.253548E+11 17206.56 01-AUG-07:10
September 0.978077E+10 10631.20 01-SEP-07:10 0.235198E+11 17206.56 01-SEP-07:10
October 0.101592E+11 10631.20 02-OCT-07:10 0.243734E+11 17206.56 02-OCT-07:10
November 0.100402E+11 10631.20 01-NOV-07:10 0.238372E+11 17206.56 01-NOV-07:10
December 0.983180E+10 10631.20 01-DEC-08:09 0.239653E+11 17206.56 01-DEC-08:09
             
Annual Sum or Average 0.121758E+12     0.289613E+12    
Minimum of Months 0.921518E+10 10631.20   0.220609E+11 17206.56  
Maximum of Months 0.109502E+11 10631.20   0.253548E+11 17206.56  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_BOT_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.852571E+09 1236.29 03-JAN-08:09 0.305979E+10 2160.55 02-JAN-08:09
February 0.767253E+09 1303.01 01-FEB-08:09 0.277008E+10 2160.55 01-FEB-08:09
March 0.808139E+09 1244.84 21-MAR-07:10 0.318369E+10 2160.55 01-MAR-08:09
April 0.690440E+09 1144.53 03-APR-07:10 0.295462E+10 2160.55 03-APR-07:10
May 0.716123E+09 842.12 24-MAY-07:10 0.312174E+10 2160.55 01-MAY-07:10
June 0.702793E+09 736.24 23-JUN-07:10 0.306580E+10 2160.55 01-JUN-07:10
July 0.668316E+09 938.49 27-JUL-07:10 0.300989E+10 2160.55 03-JUL-07:10
August 0.757895E+09 1098.41 24-AUG-07:10 0.318369E+10 2160.55 01-AUG-07:10
September 0.716158E+09 1187.12 29-SEP-07:10 0.295328E+10 2160.55 01-SEP-07:10
October 0.816125E+09 1332.07 30-OCT-07:10 0.306046E+10 2160.55 02-OCT-07:10
November 0.819184E+09 1318.01 01-NOV-07:10 0.299314E+10 2160.55 01-NOV-07:10
December 0.833495E+09 1239.01 06-DEC-08:09 0.300922E+10 2160.55 01-DEC-08:09
             
Annual Sum or Average 0.914849E+10     0.363654E+11    
Minimum of Months 0.668316E+09 736.24   0.277008E+10 2160.55  
Maximum of Months 0.852571E+09 1332.07   0.318369E+10 2160.55  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_BOT_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.524330E+09 783.06 03-JAN-08:09 0.197184E+10 1392.34 02-JAN-08:09
February 0.473477E+09 839.68 01-FEB-08:09 0.178515E+10 1392.34 01-FEB-08:09
March 0.510573E+09 795.51 21-MAR-07:10 0.205169E+10 1392.34 01-MAR-08:09
April 0.442677E+09 712.41 03-APR-07:10 0.190407E+10 1392.34 03-APR-07:10
May 0.465293E+09 455.86 02-MAY-07:10 0.201177E+10 1392.34 01-MAY-07:10
June 0.457746E+09 431.18 26-JUN-07:10 0.197572E+10 1392.34 01-JUN-07:10
July 0.433600E+09 547.55 27-JUL-07:10 0.193969E+10 1392.34 03-JUL-07:10
August 0.489431E+09 680.18 24-AUG-07:10 0.205169E+10 1392.34 01-AUG-07:10
September 0.454501E+09 747.96 29-SEP-07:10 0.190321E+10 1392.34 01-SEP-07:10
October 0.501265E+09 858.43 30-OCT-07:10 0.197228E+10 1392.34 02-OCT-07:10
November 0.510783E+09 843.53 01-NOV-07:10 0.192889E+10 1392.34 01-NOV-07:10
December 0.511088E+09 784.99 06-DEC-08:09 0.193926E+10 1392.34 01-DEC-08:09
             
Annual Sum or Average 0.577476E+10     0.234352E+11    
Minimum of Months 0.433600E+09 431.18   0.178515E+10 1392.34  
Maximum of Months 0.524330E+09 858.43   0.205169E+10 1392.34  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_BOT_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.778966E+09 1222.01 03-JAN-08:09 0.305983E+10 2160.58 02-JAN-08:09
February 0.714015E+09 1303.03 01-FEB-08:09 0.277013E+10 2160.58 01-FEB-08:09
March 0.790470E+09 1243.37 21-MAR-07:10 0.318374E+10 2160.58 01-MAR-08:09
April 0.691683E+09 1148.30 03-APR-07:10 0.295467E+10 2160.58 03-APR-07:10
May 0.726632E+09 922.37 24-MAY-07:10 0.312179E+10 2160.58 01-MAY-07:10
June 0.714550E+09 847.34 23-JUN-07:10 0.306585E+10 2160.58 01-JUN-07:10
July 0.679090E+09 984.04 27-JUL-07:10 0.300994E+10 2160.58 03-JUL-07:10
August 0.762696E+09 1109.07 24-AUG-07:10 0.318374E+10 2160.58 01-AUG-07:10
September 0.706300E+09 1178.61 29-SEP-07:10 0.295333E+10 2160.58 01-SEP-07:10
October 0.763480E+09 1332.10 30-OCT-07:10 0.306051E+10 2160.58 02-OCT-07:10
November 0.763572E+09 1312.26 01-NOV-07:10 0.299318E+10 2160.58 01-NOV-07:10
December 0.757589E+09 1223.40 06-DEC-08:09 0.300927E+10 2160.58 01-DEC-08:09
             
Annual Sum or Average 0.884904E+10     0.363660E+11    
Minimum of Months 0.679090E+09 847.34   0.277013E+10 2160.58  
Maximum of Months 0.790470E+09 1332.10   0.318374E+10 2160.58  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_BOT_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.524342E+09 799.48 03-JAN-08:09 0.197183E+10 1392.33 02-JAN-08:09
February 0.481218E+09 839.68 01-FEB-08:09 0.178514E+10 1392.33 01-FEB-08:09
March 0.520245E+09 806.10 21-MAR-07:10 0.205168E+10 1392.33 01-MAR-08:09
April 0.449014E+09 755.02 03-APR-07:10 0.190406E+10 1392.33 03-APR-07:10
May 0.469250E+09 686.56 24-MAY-07:30 0.201175E+10 1392.33 01-MAY-07:10
June 0.460101E+09 591.29 23-JUN-07:10 0.197570E+10 1392.33 01-JUN-07:10
July 0.438272E+09 662.34 27-JUL-07:10 0.193968E+10 1392.33 03-JUL-07:10
August 0.494345E+09 729.62 24-AUG-07:10 0.205168E+10 1392.33 01-AUG-07:10
September 0.463274E+09 772.43 29-SEP-07:10 0.190319E+10 1392.33 01-SEP-07:10
October 0.516101E+09 858.43 30-OCT-07:10 0.197226E+10 1392.33 02-OCT-07:10
November 0.507091E+09 850.56 01-NOV-07:10 0.192888E+10 1392.33 01-NOV-07:10
December 0.511073E+09 800.49 06-DEC-08:09 0.193924E+10 1392.33 01-DEC-08:09
             
Annual Sum or Average 0.583433E+10     0.234351E+11    
Minimum of Months 0.438272E+09 591.29   0.178514E+10 1392.33  
Maximum of Months 0.524342E+09 858.43   0.205168E+10 1392.33  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_MID_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.852301E+09 1238.36 03-JAN-08:09 0.305979E+10 2160.55 02-JAN-08:09
February 0.767412E+09 1303.69 01-FEB-08:09 0.277008E+10 2160.55 01-FEB-08:09
March 0.807836E+09 1246.79 21-MAR-07:10 0.318369E+10 2160.55 01-MAR-08:09
April 0.690350E+09 1148.64 03-APR-07:10 0.295462E+10 2160.55 03-APR-07:10
May 0.716187E+09 852.04 24-MAY-07:10 0.312174E+10 2160.55 01-MAY-07:10
June 0.702425E+09 734.24 23-JUN-07:10 0.306580E+10 2160.55 01-JUN-07:10
July 0.668539E+09 947.03 27-JUL-07:10 0.300989E+10 2160.55 03-JUL-07:10
August 0.758150E+09 1103.52 24-AUG-07:10 0.318369E+10 2160.55 01-AUG-07:10
September 0.716014E+09 1190.30 29-SEP-07:10 0.295328E+10 2160.55 01-SEP-07:10
October 0.815120E+09 1332.13 30-OCT-07:10 0.306046E+10 2160.55 02-OCT-07:10
November 0.818768E+09 1318.35 01-NOV-07:10 0.299314E+10 2160.55 01-NOV-07:10
December 0.833811E+09 1241.01 06-DEC-08:09 0.300922E+10 2160.55 01-DEC-08:09
             
Annual Sum or Average 0.914691E+10     0.363654E+11    
Minimum of Months 0.668539E+09 734.24   0.277008E+10 2160.55  
Maximum of Months 0.852301E+09 1332.13   0.318369E+10 2160.55  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_MID_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.524257E+09 783.60 03-JAN-08:09 0.197184E+10 1392.34 02-JAN-08:09
February 0.473151E+09 839.72 01-FEB-08:09 0.178515E+10 1392.34 01-FEB-08:09
March 0.510390E+09 795.90 21-MAR-07:10 0.205169E+10 1392.34 01-MAR-08:09
April 0.442572E+09 713.91 03-APR-07:10 0.190407E+10 1392.34 03-APR-07:10
May 0.465130E+09 454.38 02-MAY-07:10 0.201177E+10 1392.34 01-MAY-07:10
June 0.457587E+09 429.34 26-JUN-07:10 0.197572E+10 1392.34 01-JUN-07:10
July 0.433524E+09 550.44 27-JUL-07:10 0.193969E+10 1392.34 03-JUL-07:10
August 0.489360E+09 681.81 24-AUG-07:10 0.205169E+10 1392.34 01-AUG-07:10
September 0.454359E+09 748.74 29-SEP-07:10 0.190321E+10 1392.34 01-SEP-07:10
October 0.500749E+09 858.44 30-OCT-07:10 0.197228E+10 1392.34 02-OCT-07:10
November 0.510493E+09 843.71 01-NOV-07:10 0.192889E+10 1392.34 01-NOV-07:10
December 0.510760E+09 785.50 06-DEC-08:09 0.193926E+10 1392.34 01-DEC-08:09
             
Annual Sum or Average 0.577233E+10     0.234352E+11    
Minimum of Months 0.433524E+09 429.34   0.178515E+10 1392.34  
Maximum of Months 0.524257E+09 858.44   0.205169E+10 1392.34  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_MID_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.781030E+09 1224.65 03-JAN-08:09 0.305983E+10 2160.58 02-JAN-08:09
February 0.714748E+09 1303.71 01-FEB-08:09 0.277013E+10 2160.58 01-FEB-08:09
March 0.790803E+09 1245.37 21-MAR-07:10 0.318374E+10 2160.58 01-MAR-08:09
April 0.691759E+09 1152.28 03-APR-07:10 0.295467E+10 2160.58 03-APR-07:10
May 0.726889E+09 930.16 24-MAY-07:10 0.312179E+10 2160.58 01-MAY-07:10
June 0.714546E+09 856.93 23-JUN-07:10 0.306585E+10 2160.58 01-JUN-07:10
July 0.679279E+09 991.19 27-JUL-07:10 0.300994E+10 2160.58 03-JUL-07:10
August 0.762900E+09 1113.82 24-AUG-07:10 0.318374E+10 2160.58 01-AUG-07:10
September 0.706376E+09 1182.09 29-SEP-07:10 0.295333E+10 2160.58 01-SEP-07:10
October 0.764814E+09 1332.16 30-OCT-07:10 0.306051E+10 2160.58 02-OCT-07:10
November 0.762947E+09 1312.81 01-NOV-07:10 0.299318E+10 2160.58 01-NOV-07:10
December 0.759052E+09 1226.02 06-DEC-08:09 0.300927E+10 2160.58 01-DEC-08:09
             
Annual Sum or Average 0.885514E+10     0.363660E+11    
Minimum of Months 0.679279E+09 856.93   0.277013E+10 2160.58  
Maximum of Months 0.790803E+09 1332.16   0.318374E+10 2160.58  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_MID_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.523737E+09 799.62 03-JAN-08:09 0.197183E+10 1392.33 02-JAN-08:09
February 0.480525E+09 839.72 01-FEB-08:09 0.178514E+10 1392.33 01-FEB-08:09
March 0.520062E+09 806.21 21-MAR-07:10 0.205168E+10 1392.33 01-MAR-08:09
April 0.448772E+09 755.22 03-APR-07:10 0.190406E+10 1392.33 03-APR-07:10
May 0.469055E+09 686.49 24-MAY-07:30 0.201175E+10 1392.33 01-MAY-07:10
June 0.459967E+09 591.68 23-JUN-07:10 0.197570E+10 1392.33 01-JUN-07:10
July 0.438119E+09 662.70 27-JUL-07:10 0.193968E+10 1392.33 03-JUL-07:10
August 0.494170E+09 729.86 24-AUG-07:10 0.205168E+10 1392.33 01-AUG-07:10
September 0.463130E+09 772.60 29-SEP-07:10 0.190319E+10 1392.33 01-SEP-07:10
October 0.515440E+09 858.44 30-OCT-07:10 0.197226E+10 1392.33 02-OCT-07:10
November 0.506725E+09 850.59 01-NOV-07:10 0.192888E+10 1392.33 01-NOV-07:10
December 0.510682E+09 800.63 06-DEC-08:09 0.193924E+10 1392.33 01-DEC-08:09
             
Annual Sum or Average 0.583038E+10     0.234351E+11    
Minimum of Months 0.438119E+09 591.68   0.178514E+10 1392.33  
Maximum of Months 0.523737E+09 858.44   0.205168E+10 1392.33  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_TOP_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.852249E+09 1238.26 03-JAN-08:09 0.305979E+10 2160.55 02-JAN-08:09
February 0.767358E+09 1303.65 01-FEB-08:09 0.277008E+10 2160.55 01-FEB-08:09
March 0.807787E+09 1246.69 21-MAR-07:10 0.318369E+10 2160.55 01-MAR-08:09
April 0.690337E+09 1148.46 03-APR-07:10 0.295462E+10 2160.55 03-APR-07:10
May 0.716168E+09 851.76 24-MAY-07:10 0.312174E+10 2160.55 01-MAY-07:10
June 0.702418E+09 734.09 23-JUN-07:10 0.306580E+10 2160.55 01-JUN-07:10
July 0.668526E+09 946.69 27-JUL-07:10 0.300989E+10 2160.55 03-JUL-07:10
August 0.758115E+09 1103.28 24-AUG-07:10 0.318369E+10 2160.55 01-AUG-07:10
September 0.715977E+09 1190.14 29-SEP-07:10 0.295328E+10 2160.55 01-SEP-07:10
October 0.815046E+09 1332.13 30-OCT-07:10 0.306046E+10 2160.55 02-OCT-07:10
November 0.818691E+09 1318.33 01-NOV-07:10 0.299314E+10 2160.55 01-NOV-07:10
December 0.833829E+09 1240.90 06-DEC-08:09 0.300922E+10 2160.55 01-DEC-08:09
             
Annual Sum or Average 0.914650E+10     0.363654E+11    
Minimum of Months 0.668526E+09 734.09   0.277008E+10 2160.55  
Maximum of Months 0.852249E+09 1332.13   0.318369E+10 2160.55  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_TOP_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.524230E+09 783.54 03-JAN-08:09 0.197184E+10 1392.34 02-JAN-08:09
February 0.473124E+09 839.70 01-FEB-08:09 0.178515E+10 1392.34 01-FEB-08:09
March 0.510383E+09 795.84 21-MAR-07:10 0.205169E+10 1392.34 01-MAR-08:09
April 0.442550E+09 713.81 03-APR-07:10 0.190407E+10 1392.34 03-APR-07:10
May 0.465117E+09 454.25 02-MAY-07:10 0.201177E+10 1392.34 01-MAY-07:10
June 0.457578E+09 429.16 26-JUN-07:10 0.197572E+10 1392.34 01-JUN-07:10
July 0.433511E+09 550.28 27-JUL-07:10 0.193969E+10 1392.34 03-JUL-07:10
August 0.489346E+09 681.68 24-AUG-07:10 0.205169E+10 1392.34 01-AUG-07:10
September 0.454355E+09 748.66 29-SEP-07:10 0.190321E+10 1392.34 01-SEP-07:10
October 0.500728E+09 858.44 30-OCT-07:10 0.197228E+10 1392.34 02-OCT-07:10
November 0.510468E+09 843.71 01-NOV-07:10 0.192889E+10 1392.34 01-NOV-07:10
December 0.510725E+09 785.45 06-DEC-08:09 0.193926E+10 1392.34 01-DEC-08:09
             
Annual Sum or Average 0.577212E+10     0.234352E+11    
Minimum of Months 0.433511E+09 429.16   0.178515E+10 1392.34  
Maximum of Months 0.524230E+09 858.44   0.205169E+10 1392.34  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_TOP_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.780953E+09 1224.55 03-JAN-08:09 0.305983E+10 2160.58 02-JAN-08:09
February 0.715684E+09 1303.67 01-FEB-08:09 0.277013E+10 2160.58 01-FEB-08:09
March 0.790772E+09 1245.27 21-MAR-07:10 0.318374E+10 2160.58 01-MAR-08:09
April 0.691748E+09 1152.10 03-APR-07:10 0.295467E+10 2160.58 03-APR-07:10
May 0.726872E+09 929.90 24-MAY-07:10 0.312179E+10 2160.58 01-MAY-07:10
June 0.714532E+09 856.48 23-JUN-07:10 0.306585E+10 2160.58 01-JUN-07:10
July 0.679260E+09 990.86 27-JUL-07:10 0.300994E+10 2160.58 03-JUL-07:10
August 0.762881E+09 1113.59 24-AUG-07:10 0.318374E+10 2160.58 01-AUG-07:10
September 0.706348E+09 1181.94 29-SEP-07:10 0.295333E+10 2160.58 01-SEP-07:10
October 0.764786E+09 1332.15 30-OCT-07:10 0.306051E+10 2160.58 02-OCT-07:10
November 0.762979E+09 1312.80 01-NOV-07:10 0.299318E+10 2160.58 01-NOV-07:10
December 0.759020E+09 1225.92 06-DEC-08:09 0.300927E+10 2160.58 01-DEC-08:09
             
Annual Sum or Average 0.885583E+10     0.363660E+11    
Minimum of Months 0.679260E+09 856.48   0.277013E+10 2160.58  
Maximum of Months 0.790772E+09 1332.15   0.318374E+10 2160.58  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_TOP_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.523720E+09 799.55 03-JAN-08:09 0.197183E+10 1392.33 02-JAN-08:09
February 0.480506E+09 839.70 01-FEB-08:09 0.178514E+10 1392.33 01-FEB-08:09
March 0.520052E+09 806.15 21-MAR-07:10 0.205168E+10 1392.33 01-MAR-08:09
April 0.448811E+09 755.10 03-APR-07:10 0.190406E+10 1392.33 03-APR-07:10
May 0.469046E+09 686.39 24-MAY-07:30 0.201175E+10 1392.33 01-MAY-07:10
June 0.459969E+09 591.42 23-JUN-07:10 0.197570E+10 1392.33 01-JUN-07:10
July 0.438111E+09 662.50 27-JUL-07:10 0.193968E+10 1392.33 03-JUL-07:10
August 0.494175E+09 729.72 24-AUG-07:10 0.205168E+10 1392.33 01-AUG-07:10
September 0.463241E+09 772.51 29-SEP-07:10 0.190319E+10 1392.33 01-SEP-07:10
October 0.515418E+09 858.44 30-OCT-07:10 0.197226E+10 1392.33 02-OCT-07:10
November 0.506744E+09 850.58 01-NOV-07:10 0.192888E+10 1392.33 01-NOV-07:10
December 0.510673E+09 800.56 06-DEC-08:09 0.193924E+10 1392.33 01-DEC-08:09
             
Annual Sum or Average 0.583047E+10     0.234351E+11    
Minimum of Months 0.438111E+09 591.42   0.178514E+10 1392.33  
Maximum of Months 0.523720E+09 858.44   0.205168E+10 1392.33  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: DATACENTER_BOT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.272315E+09 284.97 02-JAN-08:09 0.521915E+10 1948.61 01-JAN-00:10
February 0.247010E+09 284.97 01-FEB-08:09 0.942813E+10 3897.21 01-FEB-00:10
March 0.293517E+09 284.97 01-MAR-08:09 0.156645E+11 7794.42 31-MAR-23:10
April 0.262171E+09 284.97 03-APR-07:10 0.201821E+11 7794.42 01-APR-00:10
May 0.282916E+09 284.97 01-MAY-07:10 0.522616E+10 3897.21 31-MAY-23:10
June 0.281548E+09 284.97 01-JUN-07:10 0.101086E+11 5845.82 30-JUN-23:10
July 0.263538E+09 284.97 03-JUL-07:10 0.156645E+11 7794.42 31-JUL-23:10
August 0.293517E+09 284.97 01-AUG-07:10 0.208555E+11 7794.42 01-AUG-00:10
September 0.262171E+09 284.97 01-SEP-07:10 0.505780E+10 3897.21 30-SEP-23:10
October 0.272315E+09 284.97 02-OCT-07:10 0.104453E+11 5845.82 31-OCT-23:10
November 0.269124E+09 284.97 01-NOV-07:10 0.151524E+11 5845.82 01-NOV-00:10
December 0.263538E+09 284.97 01-DEC-08:09 0.208766E+11 7794.42 01-DEC-00:10
             
Annual Sum or Average 0.326368E+10     0.153881E+12    
Minimum of Months 0.247010E+09 284.97   0.505780E+10 1948.61  
Maximum of Months 0.293517E+09 284.97   0.208766E+11 7794.42  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: DATACENTER_MID_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.272315E+09 284.97 02-JAN-08:09 0.521915E+10 1948.61 01-JAN-00:10
February 0.247010E+09 284.97 01-FEB-08:09 0.942813E+10 3897.21 01-FEB-00:10
March 0.293517E+09 284.97 01-MAR-08:09 0.156645E+11 7794.42 31-MAR-23:10
April 0.262171E+09 284.97 03-APR-07:10 0.201821E+11 7794.42 01-APR-00:10
May 0.282916E+09 284.97 01-MAY-07:10 0.522616E+10 3897.21 31-MAY-23:10
June 0.281548E+09 284.97 01-JUN-07:10 0.101086E+11 5845.82 30-JUN-23:10
July 0.263538E+09 284.97 03-JUL-07:10 0.156645E+11 7794.42 31-JUL-23:10
August 0.293517E+09 284.97 01-AUG-07:10 0.208555E+11 7794.42 01-AUG-00:10
September 0.262171E+09 284.97 01-SEP-07:10 0.505780E+10 3897.21 30-SEP-23:10
October 0.272315E+09 284.97 02-OCT-07:10 0.104453E+11 5845.82 31-OCT-23:10
November 0.269124E+09 284.97 01-NOV-07:10 0.151524E+11 5845.82 01-NOV-00:10
December 0.263538E+09 284.97 01-DEC-08:09 0.208766E+11 7794.42 01-DEC-00:10
             
Annual Sum or Average 0.326368E+10     0.153881E+12    
Minimum of Months 0.247010E+09 284.97   0.505780E+10 1948.61  
Maximum of Months 0.293517E+09 284.97   0.208766E+11 7794.42  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: DATACENTER_TOP_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.272315E+09 284.97 02-JAN-08:09 0.521915E+10 1948.61 01-JAN-00:10
February 0.247010E+09 284.97 01-FEB-08:09 0.942813E+10 3897.21 01-FEB-00:10
March 0.293517E+09 284.97 01-MAR-08:09 0.156645E+11 7794.42 31-MAR-23:10
April 0.262171E+09 284.97 03-APR-07:10 0.201821E+11 7794.42 01-APR-00:10
May 0.282916E+09 284.97 01-MAY-07:10 0.522616E+10 3897.21 31-MAY-23:10
June 0.281548E+09 284.97 01-JUN-07:10 0.101086E+11 5845.82 30-JUN-23:10
July 0.263538E+09 284.97 03-JUL-07:10 0.156645E+11 7794.42 31-JUL-23:10
August 0.293517E+09 284.97 01-AUG-07:10 0.208555E+11 7794.42 01-AUG-00:10
September 0.262171E+09 284.97 01-SEP-07:10 0.505780E+10 3897.21 30-SEP-23:10
October 0.272315E+09 284.97 02-OCT-07:10 0.104453E+11 5845.82 31-OCT-23:10
November 0.269124E+09 284.97 01-NOV-07:10 0.151524E+11 5845.82 01-NOV-00:10
December 0.263538E+09 284.97 01-DEC-08:09 0.208766E+11 7794.42 01-DEC-00:10
             
Annual Sum or Average 0.326368E+10     0.153881E+12    
Minimum of Months 0.247010E+09 284.97   0.505780E+10 1948.61  
Maximum of Months 0.293517E+09 284.97   0.208766E+11 7794.42  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: DATACENTER_BASEMENT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.318958E+10 3337.76 02-JAN-08:09 0.254202E+12 94908.13 01-JAN-00:10
February 0.289319E+10 3337.76 01-FEB-08:09 0.459203E+12 189816.26 01-FEB-00:10
March 0.343791E+10 3337.76 01-MAR-08:09 0.762947E+12 379632.52 31-MAR-23:10
April 0.307076E+10 3337.76 03-APR-07:10 0.982982E+12 379632.52 01-APR-00:10
May 0.331375E+10 3337.76 01-MAY-07:10 0.254544E+12 189816.26 31-MAY-23:10
June 0.329773E+10 3337.76 01-JUN-07:10 0.492345E+12 284724.39 30-JUN-23:10
July 0.308678E+10 3337.76 03-JUL-07:10 0.762947E+12 379632.52 31-JUL-23:10
August 0.343791E+10 3337.76 01-AUG-07:10 0.101578E+13 379632.52 01-AUG-00:10
September 0.307076E+10 3337.76 01-SEP-07:10 0.246344E+12 189816.26 30-SEP-23:10
October 0.318958E+10 3337.76 02-OCT-07:10 0.508746E+12 284724.39 31-OCT-23:10
November 0.315220E+10 3337.76 01-NOV-07:10 0.738006E+12 284724.39 01-NOV-00:10
December 0.308678E+10 3337.76 01-DEC-08:09 0.101681E+13 379632.52 01-DEC-00:10
             
Annual Sum or Average 0.382269E+11     0.749486E+13    
Minimum of Months 0.289319E+10 3337.76   0.246344E+12 94908.13  
Maximum of Months 0.343791E+10 3337.76   0.101681E+13 379632.52  



Table of Contents

Report: SpaceGainsMonthly

For: BASEMENT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 0.133902E+11 0.113123E+11 0.360447E+11 0.00 0.00 0.00 0.00 0.00 0.00
February 0.121482E+11 0.102611E+11 0.325565E+11 0.00 0.00 0.00 0.00 0.00 0.00
March 0.145160E+11 0.121930E+11 0.360447E+11 0.00 0.00 0.00 0.00 0.00 0.00
April 0.128805E+11 0.108909E+11 0.348820E+11 0.00 0.00 0.00 0.00 0.00 0.00
May 0.139531E+11 0.117527E+11 0.360447E+11 0.00 0.00 0.00 0.00 0.00 0.00
June 0.139143E+11 0.116958E+11 0.348820E+11 0.00 0.00 0.00 0.00 0.00 0.00
July 0.129193E+11 0.109477E+11 0.360447E+11 0.00 0.00 0.00 0.00 0.00 0.00
August 0.145160E+11 0.121930E+11 0.360447E+11 0.00 0.00 0.00 0.00 0.00 0.00
September 0.128805E+11 0.108909E+11 0.348820E+11 0.00 0.00 0.00 0.00 0.00 0.00
October 0.133902E+11 0.113123E+11 0.360447E+11 0.00 0.00 0.00 0.00 0.00 0.00
November 0.132595E+11 0.111797E+11 0.348820E+11 0.00 0.00 0.00 0.00 0.00 0.00
December 0.129193E+11 0.109477E+11 0.360447E+11 0.00 0.00 0.00 0.00 0.00 0.00
                   
Annual Sum or Average 0.160687E+12 0.135577E+12 0.424397E+12 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.121482E+11 0.102611E+11 0.325565E+11 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.145160E+11 0.121930E+11 0.360447E+11 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainsMonthly

For: CORE_BOTTOM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 0.120254E+11 0.101592E+11 0.243681E+11 0.00 0.00 0.00 0.00 0.00 0.00
February 0.109099E+11 0.921518E+10 0.220609E+11 0.00 0.00 0.00 0.00 0.00 0.00
March 0.130364E+11 0.109502E+11 0.253549E+11 0.00 0.00 0.00 0.00 0.00 0.00
April 0.115676E+11 0.978077E+10 0.235306E+11 0.00 0.00 0.00 0.00 0.00 0.00
May 0.125309E+11 0.105547E+11 0.248615E+11 0.00 0.00 0.00 0.00 0.00 0.00
June 0.124961E+11 0.105037E+11 0.244160E+11 0.00 0.00 0.00 0.00 0.00 0.00
July 0.116025E+11 0.983180E+10 0.239708E+11 0.00 0.00 0.00 0.00 0.00 0.00
August 0.130364E+11 0.109502E+11 0.253549E+11 0.00 0.00 0.00 0.00 0.00 0.00
September 0.115676E+11 0.978077E+10 0.235199E+11 0.00 0.00 0.00 0.00 0.00 0.00
October 0.120254E+11 0.101592E+11 0.243735E+11 0.00 0.00 0.00 0.00 0.00 0.00
November 0.119080E+11 0.100402E+11 0.238373E+11 0.00 0.00 0.00 0.00 0.00 0.00
December 0.116025E+11 0.983180E+10 0.239654E+11 0.00 0.00 0.00 0.00 0.00 0.00
                   
Annual Sum or Average 0.144308E+12 0.121758E+12 0.289614E+12 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.109099E+11 0.921518E+10 0.220609E+11 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.130364E+11 0.109502E+11 0.253549E+11 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainsMonthly

For: CORE_MID

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 0.120254E+11 0.101592E+11 0.243680E+11 0.00 0.00 0.00 0.00 0.00 0.00
February 0.109099E+11 0.921518E+10 0.220609E+11 0.00 0.00 0.00 0.00 0.00 0.00
March 0.130364E+11 0.109502E+11 0.253548E+11 0.00 0.00 0.00 0.00 0.00 0.00
April 0.115676E+11 0.978077E+10 0.235305E+11 0.00 0.00 0.00 0.00 0.00 0.00
May 0.125309E+11 0.105547E+11 0.248614E+11 0.00 0.00 0.00 0.00 0.00 0.00
June 0.124961E+11 0.105037E+11 0.244159E+11 0.00 0.00 0.00 0.00 0.00 0.00
July 0.116025E+11 0.983180E+10 0.239707E+11 0.00 0.00 0.00 0.00 0.00 0.00
August 0.130364E+11 0.109502E+11 0.253548E+11 0.00 0.00 0.00 0.00 0.00 0.00
September 0.115676E+11 0.978077E+10 0.235198E+11 0.00 0.00 0.00 0.00 0.00 0.00
October 0.120254E+11 0.101592E+11 0.243734E+11 0.00 0.00 0.00 0.00 0.00 0.00
November 0.119080E+11 0.100402E+11 0.238372E+11 0.00 0.00 0.00 0.00 0.00 0.00
December 0.116025E+11 0.983180E+10 0.239653E+11 0.00 0.00 0.00 0.00 0.00 0.00
                   
Annual Sum or Average 0.144308E+12 0.121758E+12 0.289613E+12 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.109099E+11 0.921518E+10 0.220609E+11 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.130364E+11 0.109502E+11 0.253548E+11 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainsMonthly

For: CORE_TOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 0.120254E+11 0.101592E+11 0.243680E+11 0.00 0.00 0.00 0.00 0.00 0.00
February 0.109099E+11 0.921518E+10 0.220609E+11 0.00 0.00 0.00 0.00 0.00 0.00
March 0.130364E+11 0.109502E+11 0.253548E+11 0.00 0.00 0.00 0.00 0.00 0.00
April 0.115676E+11 0.978077E+10 0.235305E+11 0.00 0.00 0.00 0.00 0.00 0.00
May 0.125309E+11 0.105547E+11 0.248614E+11 0.00 0.00 0.00 0.00 0.00 0.00
June 0.124961E+11 0.105037E+11 0.244159E+11 0.00 0.00 0.00 0.00 0.00 0.00
July 0.116025E+11 0.983180E+10 0.239707E+11 0.00 0.00 0.00 0.00 0.00 0.00
August 0.130364E+11 0.109502E+11 0.253548E+11 0.00 0.00 0.00 0.00 0.00 0.00
September 0.115676E+11 0.978077E+10 0.235198E+11 0.00 0.00 0.00 0.00 0.00 0.00
October 0.120254E+11 0.101592E+11 0.243734E+11 0.00 0.00 0.00 0.00 0.00 0.00
November 0.119080E+11 0.100402E+11 0.238372E+11 0.00 0.00 0.00 0.00 0.00 0.00
December 0.116025E+11 0.983180E+10 0.239653E+11 0.00 0.00 0.00 0.00 0.00 0.00
                   
Annual Sum or Average 0.144308E+12 0.121758E+12 0.289613E+12 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.109099E+11 0.921518E+10 0.220609E+11 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.130364E+11 0.109502E+11 0.253548E+11 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_BOT_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.150991E+10 0.852571E+09 0.305979E+10 0.00 0.00 0.00 0.00 0.00 0.246228E+09
February 0.136985E+10 0.767253E+09 0.277008E+10 0.00 0.00 0.00 0.00 89040.48 0.210481E+09
March 0.163685E+10 0.808139E+09 0.318369E+10 0.00 0.00 0.00 0.00 395717.32 0.136922E+09
April 0.145243E+10 0.690440E+09 0.295462E+10 0.00 0.00 0.00 0.00 1154537.11 80297235.55
May 0.157338E+10 0.716123E+09 0.312174E+10 0.00 0.00 0.00 0.00 3458254.55 51311152.15
June 0.156900E+10 0.702793E+09 0.306580E+10 0.00 0.00 0.00 0.00 14733059.65 22671953.99
July 0.145680E+10 0.668316E+09 0.300989E+10 0.00 0.00 0.00 0.00 16215289.52 13935761.70
August 0.163685E+10 0.757895E+09 0.318369E+10 0.00 0.00 0.00 0.00 15584014.79 6984616.31
September 0.145243E+10 0.716158E+09 0.295328E+10 0.00 0.00 0.00 0.00 4304022.29 26787925.63
October 0.150991E+10 0.816125E+09 0.306046E+10 0.00 0.00 0.00 0.00 972341.48 92869191.31
November 0.149516E+10 0.819184E+09 0.299314E+10 0.00 0.00 0.00 0.00 3285.74 0.136943E+09
December 0.145680E+10 0.833495E+09 0.300922E+10 0.00 0.00 0.00 0.00 0.00 0.239970E+09
                   
Annual Sum or Average 0.181194E+11 0.914849E+10 0.363654E+11 0.00 0.00 0.00 0.00 56909562.93 0.126540E+10
Minimum of Months 0.136985E+10 0.668316E+09 0.277008E+10 0.00 0.00 0.00 0.00 0.00 6984616.31
Maximum of Months 0.163685E+10 0.852571E+09 0.318369E+10 0.00 0.00 0.00 0.00 16215289.52 0.246228E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_BOT_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.973041E+09 0.524330E+09 0.197184E+10 0.00 0.00 0.00 0.00 0.00 0.165301E+09
February 0.882782E+09 0.473477E+09 0.178515E+10 0.00 0.00 0.00 0.00 20950.93 0.140715E+09
March 0.105485E+10 0.510573E+09 0.205169E+10 0.00 0.00 0.00 0.00 275252.58 90616108.93
April 0.936002E+09 0.442677E+09 0.190407E+10 0.00 0.00 0.00 0.00 718691.67 52108481.92
May 0.101394E+10 0.465293E+09 0.201177E+10 0.00 0.00 0.00 0.00 2112218.77 35046135.23
June 0.101113E+10 0.457746E+09 0.197572E+10 0.00 0.00 0.00 0.00 9666204.64 14762211.12
July 0.938820E+09 0.433600E+09 0.193969E+10 0.00 0.00 0.00 0.00 10771386.80 8715480.91
August 0.105485E+10 0.489431E+09 0.205169E+10 0.00 0.00 0.00 0.00 10572382.45 3825685.45
September 0.936002E+09 0.454501E+09 0.190321E+10 0.00 0.00 0.00 0.00 2742000.22 17636539.72
October 0.973041E+09 0.501265E+09 0.197228E+10 0.00 0.00 0.00 0.00 564558.50 61560269.97
November 0.963541E+09 0.510783E+09 0.192889E+10 0.00 0.00 0.00 0.00 13105.15 90374399.26
December 0.938820E+09 0.511088E+09 0.193926E+10 0.00 0.00 0.00 0.00 0.00 0.156799E+09
                   
Annual Sum or Average 0.116768E+11 0.577476E+10 0.234352E+11 0.00 0.00 0.00 0.00 37456751.71 0.837461E+09
Minimum of Months 0.882782E+09 0.433600E+09 0.178515E+10 0.00 0.00 0.00 0.00 0.00 3825685.45
Maximum of Months 0.105485E+10 0.524330E+09 0.205169E+10 0.00 0.00 0.00 0.00 10771386.80 0.165301E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_BOT_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.150994E+10 0.778966E+09 0.305983E+10 0.00 0.00 0.00 0.00 0.00 0.249667E+09
February 0.136988E+10 0.714015E+09 0.277013E+10 0.00 0.00 0.00 0.00 23885.12 0.214739E+09
March 0.163688E+10 0.790470E+09 0.318374E+10 0.00 0.00 0.00 0.00 374085.13 0.141907E+09
April 0.145246E+10 0.691683E+09 0.295467E+10 0.00 0.00 0.00 0.00 943422.22 81221405.37
May 0.157341E+10 0.726632E+09 0.312179E+10 0.00 0.00 0.00 0.00 3223413.48 51717764.72
June 0.156904E+10 0.714550E+09 0.306585E+10 0.00 0.00 0.00 0.00 14552951.00 22663560.67
July 0.145684E+10 0.679090E+09 0.300994E+10 0.00 0.00 0.00 0.00 15854491.69 13996415.26
August 0.163688E+10 0.762696E+09 0.318374E+10 0.00 0.00 0.00 0.00 14839253.71 7668592.15
September 0.145246E+10 0.706300E+09 0.295333E+10 0.00 0.00 0.00 0.00 3688127.67 27548922.82
October 0.150994E+10 0.763480E+09 0.306051E+10 0.00 0.00 0.00 0.00 606610.42 96064330.40
November 0.149520E+10 0.763572E+09 0.299318E+10 0.00 0.00 0.00 0.00 0.00 0.140922E+09
December 0.145684E+10 0.757589E+09 0.300927E+10 0.00 0.00 0.00 0.00 0.00 0.238732E+09
                   
Annual Sum or Average 0.181198E+11 0.884904E+10 0.363660E+11 0.00 0.00 0.00 0.00 54106240.45 0.128685E+10
Minimum of Months 0.136988E+10 0.679090E+09 0.277013E+10 0.00 0.00 0.00 0.00 0.00 7668592.15
Maximum of Months 0.163688E+10 0.790470E+09 0.318374E+10 0.00 0.00 0.00 0.00 15854491.69 0.249667E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_BOT_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.973041E+09 0.524342E+09 0.197183E+10 0.00 0.00 0.00 0.00 0.00 0.173967E+09
February 0.882782E+09 0.481218E+09 0.178514E+10 0.00 0.00 0.00 0.00 15929.18 0.153902E+09
March 0.105485E+10 0.520245E+09 0.205168E+10 0.00 0.00 0.00 0.00 248959.45 0.105649E+09
April 0.936002E+09 0.449014E+09 0.190406E+10 0.00 0.00 0.00 0.00 611214.91 63549002.33
May 0.101394E+10 0.469250E+09 0.201175E+10 0.00 0.00 0.00 0.00 1969180.02 39016636.79
June 0.101113E+10 0.460101E+09 0.197570E+10 0.00 0.00 0.00 0.00 8987189.82 18705856.26
July 0.938820E+09 0.438272E+09 0.193968E+10 0.00 0.00 0.00 0.00 9482972.48 12352252.04
August 0.105485E+10 0.494345E+09 0.205168E+10 0.00 0.00 0.00 0.00 9031664.53 8178642.40
September 0.936002E+09 0.463274E+09 0.190319E+10 0.00 0.00 0.00 0.00 2504650.01 20911693.87
October 0.973041E+09 0.516101E+09 0.197226E+10 0.00 0.00 0.00 0.00 418750.92 70229465.11
November 0.963541E+09 0.507091E+09 0.192888E+10 0.00 0.00 0.00 0.00 0.00 0.103028E+09
December 0.938820E+09 0.511073E+09 0.193924E+10 0.00 0.00 0.00 0.00 0.00 0.180143E+09
                   
Annual Sum or Average 0.116768E+11 0.583433E+10 0.234351E+11 0.00 0.00 0.00 0.00 33270511.32 0.949633E+09
Minimum of Months 0.882782E+09 0.438272E+09 0.178514E+10 0.00 0.00 0.00 0.00 0.00 8178642.40
Maximum of Months 0.105485E+10 0.524342E+09 0.205168E+10 0.00 0.00 0.00 0.00 9482972.48 0.180143E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_MID_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.150991E+10 0.852301E+09 0.305979E+10 0.00 0.00 0.00 0.00 0.00 0.503422E+09
February 0.136985E+10 0.767412E+09 0.277008E+10 0.00 0.00 0.00 0.00 897169.53 0.429853E+09
March 0.163685E+10 0.807836E+09 0.318369E+10 0.00 0.00 0.00 0.00 1116173.44 0.285220E+09
April 0.145243E+10 0.690350E+09 0.295462E+10 0.00 0.00 0.00 0.00 3086241.42 0.178435E+09
May 0.157338E+10 0.716187E+09 0.312174E+10 0.00 0.00 0.00 0.00 8287483.83 0.115636E+09
June 0.156900E+10 0.702425E+09 0.306580E+10 0.00 0.00 0.00 0.00 34157539.37 57112250.19
July 0.145680E+10 0.668539E+09 0.300989E+10 0.00 0.00 0.00 0.00 37416406.15 36710095.88
August 0.163685E+10 0.758150E+09 0.318369E+10 0.00 0.00 0.00 0.00 36680026.84 22146766.00
September 0.145243E+10 0.716014E+09 0.295328E+10 0.00 0.00 0.00 0.00 10575103.88 58869324.37
October 0.150991E+10 0.815120E+09 0.306046E+10 0.00 0.00 0.00 0.00 3243793.84 0.192196E+09
November 0.149516E+10 0.818768E+09 0.299314E+10 0.00 0.00 0.00 0.00 151577.16 0.275088E+09
December 0.145680E+10 0.833811E+09 0.300922E+10 0.00 0.00 0.00 0.00 0.00 0.469826E+09
                   
Annual Sum or Average 0.181194E+11 0.914691E+10 0.363654E+11 0.00 0.00 0.00 0.00 0.135612E+09 0.262451E+10
Minimum of Months 0.136985E+10 0.668539E+09 0.277008E+10 0.00 0.00 0.00 0.00 0.00 22146766.00
Maximum of Months 0.163685E+10 0.852301E+09 0.318369E+10 0.00 0.00 0.00 0.00 37416406.15 0.503422E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_MID_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.715730E+09 0.524257E+09 0.197184E+10 0.00 0.00 0.00 0.00 0.00 0.342982E+09
February 0.649041E+09 0.473151E+09 0.178515E+10 0.00 0.00 0.00 0.00 136849.09 0.296115E+09
March 0.773965E+09 0.510390E+09 0.205169E+10 0.00 0.00 0.00 0.00 694417.35 0.200294E+09
April 0.688021E+09 0.442572E+09 0.190407E+10 0.00 0.00 0.00 0.00 1527889.90 0.124541E+09
May 0.744847E+09 0.465130E+09 0.201177E+10 0.00 0.00 0.00 0.00 4686928.67 82135098.55
June 0.742030E+09 0.457587E+09 0.197572E+10 0.00 0.00 0.00 0.00 21563054.79 40168996.90
July 0.690839E+09 0.433524E+09 0.193969E+10 0.00 0.00 0.00 0.00 23318673.62 26024123.72
August 0.773965E+09 0.489360E+09 0.205169E+10 0.00 0.00 0.00 0.00 22946197.06 16021357.91
September 0.688021E+09 0.454359E+09 0.190321E+10 0.00 0.00 0.00 0.00 6283830.48 40545462.22
October 0.715730E+09 0.500749E+09 0.197228E+10 0.00 0.00 0.00 0.00 1408361.58 0.133883E+09
November 0.708685E+09 0.510493E+09 0.192889E+10 0.00 0.00 0.00 0.00 53020.12 0.190859E+09
December 0.690839E+09 0.510760E+09 0.193926E+10 0.00 0.00 0.00 0.00 0.00 0.319029E+09
                   
Annual Sum or Average 0.858171E+10 0.577233E+10 0.234352E+11 0.00 0.00 0.00 0.00 82619222.64 0.181260E+10
Minimum of Months 0.649041E+09 0.433524E+09 0.178515E+10 0.00 0.00 0.00 0.00 0.00 16021357.91
Maximum of Months 0.773965E+09 0.524257E+09 0.205169E+10 0.00 0.00 0.00 0.00 23318673.62 0.342982E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_MID_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.150994E+10 0.781030E+09 0.305983E+10 0.00 0.00 0.00 0.00 0.00 0.553020E+09
February 0.136988E+10 0.714748E+09 0.277013E+10 0.00 0.00 0.00 0.00 47923.50 0.474727E+09
March 0.163688E+10 0.790803E+09 0.318374E+10 0.00 0.00 0.00 0.00 820995.37 0.321532E+09
April 0.145246E+10 0.691759E+09 0.295467E+10 0.00 0.00 0.00 0.00 2090908.62 0.189151E+09
May 0.157341E+10 0.726889E+09 0.312179E+10 0.00 0.00 0.00 0.00 7402724.92 0.118928E+09
June 0.156904E+10 0.714546E+09 0.306585E+10 0.00 0.00 0.00 0.00 33710882.80 57188546.16
July 0.145684E+10 0.679279E+09 0.300994E+10 0.00 0.00 0.00 0.00 36381815.30 37132439.56
August 0.163688E+10 0.762900E+09 0.318374E+10 0.00 0.00 0.00 0.00 34014325.67 24517737.89
September 0.145246E+10 0.706376E+09 0.295333E+10 0.00 0.00 0.00 0.00 8295642.52 63741759.09
October 0.150994E+10 0.764814E+09 0.306051E+10 0.00 0.00 0.00 0.00 1282066.57 0.217292E+09
November 0.149520E+10 0.762947E+09 0.299318E+10 0.00 0.00 0.00 0.00 0.00 0.316503E+09
December 0.145684E+10 0.759052E+09 0.300927E+10 0.00 0.00 0.00 0.00 0.00 0.515136E+09
                   
Annual Sum or Average 0.181198E+11 0.885514E+10 0.363660E+11 0.00 0.00 0.00 0.00 0.124047E+09 0.288887E+10
Minimum of Months 0.136988E+10 0.679279E+09 0.277013E+10 0.00 0.00 0.00 0.00 0.00 24517737.89
Maximum of Months 0.163688E+10 0.790803E+09 0.318374E+10 0.00 0.00 0.00 0.00 36381815.30 0.553020E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_MID_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.973041E+09 0.523737E+09 0.197183E+10 0.00 0.00 0.00 0.00 0.00 0.353894E+09
February 0.882782E+09 0.480525E+09 0.178514E+10 0.00 0.00 0.00 0.00 222293.88 0.305050E+09
March 0.105485E+10 0.520062E+09 0.205168E+10 0.00 0.00 0.00 0.00 553239.68 0.213533E+09
April 0.936002E+09 0.448772E+09 0.190406E+10 0.00 0.00 0.00 0.00 1501537.77 0.132451E+09
May 0.101394E+10 0.469055E+09 0.201175E+10 0.00 0.00 0.00 0.00 4590584.63 85703388.98
June 0.101113E+10 0.459967E+09 0.197570E+10 0.00 0.00 0.00 0.00 21051573.93 43325590.31
July 0.938820E+09 0.438119E+09 0.193968E+10 0.00 0.00 0.00 0.00 22602284.42 28164702.99
August 0.105485E+10 0.494170E+09 0.205168E+10 0.00 0.00 0.00 0.00 21462481.39 19830292.10
September 0.936002E+09 0.463130E+09 0.190319E+10 0.00 0.00 0.00 0.00 5996187.66 43941485.80
October 0.973041E+09 0.515440E+09 0.197226E+10 0.00 0.00 0.00 0.00 1147446.54 0.141071E+09
November 0.963541E+09 0.506725E+09 0.192888E+10 0.00 0.00 0.00 0.00 0.00 0.199372E+09
December 0.938820E+09 0.510682E+09 0.193924E+10 0.00 0.00 0.00 0.00 0.00 0.331322E+09
                   
Annual Sum or Average 0.116768E+11 0.583038E+10 0.234351E+11 0.00 0.00 0.00 0.00 79127629.90 0.189766E+10
Minimum of Months 0.882782E+09 0.438119E+09 0.178514E+10 0.00 0.00 0.00 0.00 0.00 19830292.10
Maximum of Months 0.105485E+10 0.523737E+09 0.205168E+10 0.00 0.00 0.00 0.00 22602284.42 0.353894E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_TOP_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.150991E+10 0.852249E+09 0.305979E+10 0.00 0.00 0.00 0.00 0.00 0.579053E+09
February 0.136985E+10 0.767358E+09 0.277008E+10 0.00 0.00 0.00 0.00 1703802.17 0.499269E+09
March 0.163685E+10 0.807787E+09 0.318369E+10 0.00 0.00 0.00 0.00 1507118.29 0.325019E+09
April 0.145243E+10 0.690337E+09 0.295462E+10 0.00 0.00 0.00 0.00 3707770.00 0.209599E+09
May 0.157338E+10 0.716168E+09 0.312174E+10 0.00 0.00 0.00 0.00 9281733.33 0.142786E+09
June 0.156900E+10 0.702418E+09 0.306580E+10 0.00 0.00 0.00 0.00 39778424.39 72891818.47
July 0.145680E+10 0.668526E+09 0.300989E+10 0.00 0.00 0.00 0.00 42876457.31 47067560.63
August 0.163685E+10 0.758115E+09 0.318369E+10 0.00 0.00 0.00 0.00 41988338.05 29387399.34
September 0.145243E+10 0.715977E+09 0.295328E+10 0.00 0.00 0.00 0.00 12316422.91 70411394.33
October 0.150991E+10 0.815046E+09 0.306046E+10 0.00 0.00 0.00 0.00 4551630.73 0.217072E+09
November 0.149516E+10 0.818691E+09 0.299314E+10 0.00 0.00 0.00 0.00 1061055.62 0.302293E+09
December 0.145680E+10 0.833829E+09 0.300922E+10 0.00 0.00 0.00 0.00 0.00 0.519243E+09
                   
Annual Sum or Average 0.181194E+11 0.914650E+10 0.363654E+11 0.00 0.00 0.00 0.00 0.158773E+09 0.301409E+10
Minimum of Months 0.136985E+10 0.668526E+09 0.277008E+10 0.00 0.00 0.00 0.00 0.00 29387399.34
Maximum of Months 0.163685E+10 0.852249E+09 0.318369E+10 0.00 0.00 0.00 0.00 42876457.31 0.579053E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_TOP_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.973041E+09 0.524230E+09 0.197184E+10 0.00 0.00 0.00 0.00 0.00 0.393122E+09
February 0.882782E+09 0.473124E+09 0.178515E+10 0.00 0.00 0.00 0.00 365544.60 0.342686E+09
March 0.105485E+10 0.510383E+09 0.205169E+10 0.00 0.00 0.00 0.00 899425.02 0.231697E+09
April 0.936002E+09 0.442550E+09 0.190407E+10 0.00 0.00 0.00 0.00 1724409.95 0.148603E+09
May 0.101394E+10 0.465117E+09 0.201177E+10 0.00 0.00 0.00 0.00 5284570.99 0.102475E+09
June 0.101113E+10 0.457578E+09 0.197572E+10 0.00 0.00 0.00 0.00 25507775.22 51446854.20
July 0.938820E+09 0.433511E+09 0.193969E+10 0.00 0.00 0.00 0.00 27391598.15 33319345.77
August 0.105485E+10 0.489346E+09 0.205169E+10 0.00 0.00 0.00 0.00 26828263.71 21165749.67
September 0.936002E+09 0.454355E+09 0.190321E+10 0.00 0.00 0.00 0.00 7285975.85 48952419.07
October 0.973041E+09 0.500728E+09 0.197228E+10 0.00 0.00 0.00 0.00 1765508.29 0.153741E+09
November 0.963541E+09 0.510468E+09 0.192889E+10 0.00 0.00 0.00 0.00 536444.37 0.211387E+09
December 0.938820E+09 0.510725E+09 0.193926E+10 0.00 0.00 0.00 0.00 0.00 0.352102E+09
                   
Annual Sum or Average 0.116768E+11 0.577212E+10 0.234352E+11 0.00 0.00 0.00 0.00 97589516.16 0.209070E+10
Minimum of Months 0.882782E+09 0.433511E+09 0.178515E+10 0.00 0.00 0.00 0.00 0.00 21165749.67
Maximum of Months 0.105485E+10 0.524230E+09 0.205169E+10 0.00 0.00 0.00 0.00 27391598.15 0.393122E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_TOP_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.150994E+10 0.780953E+09 0.305983E+10 0.00 0.00 0.00 0.00 0.00 0.627911E+09
February 0.136988E+10 0.715684E+09 0.277013E+10 0.00 0.00 0.00 0.00 50307.87 0.545365E+09
March 0.163688E+10 0.790772E+09 0.318374E+10 0.00 0.00 0.00 0.00 961919.55 0.374478E+09
April 0.145246E+10 0.691748E+09 0.295467E+10 0.00 0.00 0.00 0.00 2427856.77 0.224729E+09
May 0.157341E+10 0.726872E+09 0.312179E+10 0.00 0.00 0.00 0.00 8349657.91 0.147483E+09
June 0.156904E+10 0.714532E+09 0.306585E+10 0.00 0.00 0.00 0.00 39432104.01 73017578.31
July 0.145684E+10 0.679260E+09 0.300994E+10 0.00 0.00 0.00 0.00 42080599.95 47594286.65
August 0.163688E+10 0.762881E+09 0.318374E+10 0.00 0.00 0.00 0.00 39827445.89 32506442.15
September 0.145246E+10 0.706348E+09 0.295333E+10 0.00 0.00 0.00 0.00 9704852.89 77176374.26
October 0.150994E+10 0.764786E+09 0.306051E+10 0.00 0.00 0.00 0.00 1499629.05 0.252444E+09
November 0.149520E+10 0.762979E+09 0.299318E+10 0.00 0.00 0.00 0.00 0.00 0.355675E+09
December 0.145684E+10 0.759020E+09 0.300927E+10 0.00 0.00 0.00 0.00 0.00 0.568701E+09
                   
Annual Sum or Average 0.181198E+11 0.885583E+10 0.363660E+11 0.00 0.00 0.00 0.00 0.144334E+09 0.332708E+10
Minimum of Months 0.136988E+10 0.679260E+09 0.277013E+10 0.00 0.00 0.00 0.00 0.00 32506442.15
Maximum of Months 0.163688E+10 0.790772E+09 0.318374E+10 0.00 0.00 0.00 0.00 42080599.95 0.627911E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_TOP_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.973041E+09 0.523720E+09 0.197183E+10 0.00 0.00 0.00 0.00 0.00 0.405385E+09
February 0.882782E+09 0.480506E+09 0.178514E+10 0.00 0.00 0.00 0.00 408309.25 0.354330E+09
March 0.105485E+10 0.520052E+09 0.205168E+10 0.00 0.00 0.00 0.00 667999.27 0.249198E+09
April 0.936002E+09 0.448811E+09 0.190406E+10 0.00 0.00 0.00 0.00 1779134.76 0.158109E+09
May 0.101394E+10 0.469046E+09 0.201175E+10 0.00 0.00 0.00 0.00 5475875.35 0.106029E+09
June 0.101113E+10 0.459969E+09 0.197570E+10 0.00 0.00 0.00 0.00 25312233.45 54659671.09
July 0.938820E+09 0.438111E+09 0.193968E+10 0.00 0.00 0.00 0.00 27086693.96 35378697.28
August 0.105485E+10 0.494175E+09 0.205168E+10 0.00 0.00 0.00 0.00 25738505.97 25413994.92
September 0.936002E+09 0.463241E+09 0.190319E+10 0.00 0.00 0.00 0.00 7172640.52 53030750.42
October 0.973041E+09 0.515418E+09 0.197226E+10 0.00 0.00 0.00 0.00 1460233.06 0.163395E+09
November 0.963541E+09 0.506744E+09 0.192888E+10 0.00 0.00 0.00 0.00 2123.44 0.224891E+09
December 0.938820E+09 0.510673E+09 0.193924E+10 0.00 0.00 0.00 0.00 0.00 0.372679E+09
                   
Annual Sum or Average 0.116768E+11 0.583047E+10 0.234351E+11 0.00 0.00 0.00 0.00 95103749.03 0.220250E+10
Minimum of Months 0.882782E+09 0.438111E+09 0.178514E+10 0.00 0.00 0.00 0.00 0.00 25413994.92
Maximum of Months 0.105485E+10 0.523720E+09 0.205168E+10 0.00 0.00 0.00 0.00 27086693.96 0.405385E+09



Table of Contents

Report: SpaceGainsMonthly

For: DATACENTER_BOT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 0.174411E+09 0.272315E+09 0.521915E+10 0.00 0.00 0.00 0.00 0.00 0.00
February 0.158233E+09 0.247010E+09 0.942813E+10 0.00 0.00 0.00 0.00 0.00 0.00
March 0.189074E+09 0.293517E+09 0.156645E+11 0.00 0.00 0.00 0.00 0.00 0.00
April 0.167772E+09 0.262171E+09 0.201821E+11 0.00 0.00 0.00 0.00 0.00 0.00
May 0.181743E+09 0.282916E+09 0.522616E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.181238E+09 0.281548E+09 0.101086E+11 0.00 0.00 0.00 0.00 0.00 0.00
July 0.168277E+09 0.263538E+09 0.156645E+11 0.00 0.00 0.00 0.00 0.00 0.00
August 0.189074E+09 0.293517E+09 0.208555E+11 0.00 0.00 0.00 0.00 0.00 0.00
September 0.167772E+09 0.262171E+09 0.505780E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.174411E+09 0.272315E+09 0.104453E+11 0.00 0.00 0.00 0.00 0.00 0.00
November 0.172708E+09 0.269124E+09 0.151524E+11 0.00 0.00 0.00 0.00 0.00 0.00
December 0.168277E+09 0.263538E+09 0.208766E+11 0.00 0.00 0.00 0.00 0.00 0.00
                   
Annual Sum or Average 0.209299E+10 0.326368E+10 0.153881E+12 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.158233E+09 0.247010E+09 0.505780E+10 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.189074E+09 0.293517E+09 0.208766E+11 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainsMonthly

For: DATACENTER_MID_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 0.174411E+09 0.272315E+09 0.521915E+10 0.00 0.00 0.00 0.00 0.00 0.00
February 0.158233E+09 0.247010E+09 0.942813E+10 0.00 0.00 0.00 0.00 0.00 0.00
March 0.189074E+09 0.293517E+09 0.156645E+11 0.00 0.00 0.00 0.00 0.00 0.00
April 0.167772E+09 0.262171E+09 0.201821E+11 0.00 0.00 0.00 0.00 0.00 0.00
May 0.181743E+09 0.282916E+09 0.522616E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.181238E+09 0.281548E+09 0.101086E+11 0.00 0.00 0.00 0.00 0.00 0.00
July 0.168277E+09 0.263538E+09 0.156645E+11 0.00 0.00 0.00 0.00 0.00 0.00
August 0.189074E+09 0.293517E+09 0.208555E+11 0.00 0.00 0.00 0.00 0.00 0.00
September 0.167772E+09 0.262171E+09 0.505780E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.174411E+09 0.272315E+09 0.104453E+11 0.00 0.00 0.00 0.00 0.00 0.00
November 0.172708E+09 0.269124E+09 0.151524E+11 0.00 0.00 0.00 0.00 0.00 0.00
December 0.168277E+09 0.263538E+09 0.208766E+11 0.00 0.00 0.00 0.00 0.00 0.00
                   
Annual Sum or Average 0.209299E+10 0.326368E+10 0.153881E+12 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.158233E+09 0.247010E+09 0.505780E+10 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.189074E+09 0.293517E+09 0.208766E+11 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainsMonthly

For: DATACENTER_TOP_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 0.174411E+09 0.272315E+09 0.521915E+10 0.00 0.00 0.00 0.00 0.00 0.00
February 0.158233E+09 0.247010E+09 0.942813E+10 0.00 0.00 0.00 0.00 0.00 0.00
March 0.189074E+09 0.293517E+09 0.156645E+11 0.00 0.00 0.00 0.00 0.00 0.00
April 0.167772E+09 0.262171E+09 0.201821E+11 0.00 0.00 0.00 0.00 0.00 0.00
May 0.181743E+09 0.282916E+09 0.522616E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.181238E+09 0.281548E+09 0.101086E+11 0.00 0.00 0.00 0.00 0.00 0.00
July 0.168277E+09 0.263538E+09 0.156645E+11 0.00 0.00 0.00 0.00 0.00 0.00
August 0.189074E+09 0.293517E+09 0.208555E+11 0.00 0.00 0.00 0.00 0.00 0.00
September 0.167772E+09 0.262171E+09 0.505780E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.174411E+09 0.272315E+09 0.104453E+11 0.00 0.00 0.00 0.00 0.00 0.00
November 0.172708E+09 0.269124E+09 0.151524E+11 0.00 0.00 0.00 0.00 0.00 0.00
December 0.168277E+09 0.263538E+09 0.208766E+11 0.00 0.00 0.00 0.00 0.00 0.00
                   
Annual Sum or Average 0.209299E+10 0.326368E+10 0.153881E+12 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.158233E+09 0.247010E+09 0.505780E+10 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.189074E+09 0.293517E+09 0.208766E+11 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainsMonthly

For: DATACENTER_BASEMENT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 0.377547E+10 0.318958E+10 0.254202E+12 0.00 0.00 0.00 0.00 0.00 0.00
February 0.342526E+10 0.289319E+10 0.459203E+12 0.00 0.00 0.00 0.00 0.00 0.00
March 0.409289E+10 0.343791E+10 0.762947E+12 0.00 0.00 0.00 0.00 0.00 0.00
April 0.363176E+10 0.307076E+10 0.982982E+12 0.00 0.00 0.00 0.00 0.00 0.00
May 0.393418E+10 0.331375E+10 0.254544E+12 0.00 0.00 0.00 0.00 0.00 0.00
June 0.392325E+10 0.329773E+10 0.492345E+12 0.00 0.00 0.00 0.00 0.00 0.00
July 0.364269E+10 0.308678E+10 0.762947E+12 0.00 0.00 0.00 0.00 0.00 0.00
August 0.409289E+10 0.343791E+10 0.101578E+13 0.00 0.00 0.00 0.00 0.00 0.00
September 0.363176E+10 0.307076E+10 0.246344E+12 0.00 0.00 0.00 0.00 0.00 0.00
October 0.377547E+10 0.318958E+10 0.508746E+12 0.00 0.00 0.00 0.00 0.00 0.00
November 0.373861E+10 0.315220E+10 0.738006E+12 0.00 0.00 0.00 0.00 0.00 0.00
December 0.364269E+10 0.308678E+10 0.101681E+13 0.00 0.00 0.00 0.00 0.00 0.00
                   
Annual Sum or Average 0.453069E+11 0.382269E+11 0.749486E+13 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.342526E+10 0.289319E+10 0.246344E+12 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.409289E+10 0.343791E+10 0.101681E+13 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainsMonthly

For: GROUNDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.533425E+09
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 21252.22 0.454717E+09
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 526480.93 0.293649E+09
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1623002.29 0.172654E+09
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5753066.65 0.107163E+09
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 26965627.20 49041202.36
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 30773146.20 31443341.22
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 28342795.08 18490074.87
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 7092244.50 56803677.60
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1212331.35 0.198540E+09
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.294240E+09
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.512443E+09
                   
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.102310E+09 0.272261E+10
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 18490074.87
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 30773146.20 0.533425E+09



Table of Contents

Report: SpaceGainsMonthly

For: MIDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.875406E+09
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 310807.08 0.754543E+09
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1106893.90 0.499794E+09
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 3336871.25 0.300409E+09
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 11081639.29 0.188884E+09
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 49216823.59 88589550.27
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 56676961.01 56821554.53
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 52518738.17 34261258.67
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 13692856.23 98700087.51
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2901464.08 0.337185E+09
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 100728.65 0.490848E+09
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.835289E+09
                   
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.190944E+09 0.456073E+10
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 34261258.67
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 56676961.01 0.875406E+09



Table of Contents

Report: SpaceGainsMonthly

For: TOPFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.867287E+09
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 341277.77 0.760706E+09
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 727031.54 0.523484E+09
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1537756.55 0.327705E+09
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 6739787.82 0.216978E+09
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 43224985.85 0.103701E+09
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 49123321.69 68344770.17
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 46861800.23 42675287.80
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 10602411.75 0.106453E+09
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1900845.86 0.346976E+09
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 573197.95 0.481346E+09
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.802046E+09
                   
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.161632E+09 0.464770E+10
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 42675287.80
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 49123321.69 0.867287E+09



Table of Contents

Report: PeakSpaceGainsMonthly

For: BASEMENT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 17832.21 02-JAN-10:09 11837.83 02-JAN-08:09 13457.54 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00 0.00
February 17832.21 01-FEB-10:09 11837.83 01-FEB-08:09 13457.54 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00 0.00
March 17832.21 01-MAR-10:09 11837.83 01-MAR-08:09 13457.54 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00 0.00
April 17832.21 03-APR-09:09 11837.83 03-APR-07:10 13457.54 01-APR-00:10 0.00 0.00 0.00 0.00 0.00 0.00
May 17832.21 01-MAY-09:09 11837.83 01-MAY-07:10 13457.54 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00 0.00
June 17832.21 01-JUN-09:09 11837.83 01-JUN-07:10 13457.54 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00 0.00
July 17832.21 03-JUL-09:09 11837.83 03-JUL-07:10 13457.54 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00 0.00
August 17832.21 01-AUG-09:09 11837.83 01-AUG-07:10 13457.54 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00 0.00
September 17832.21 01-SEP-09:09 11837.83 01-SEP-07:10 13457.54 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00 0.00
October 17832.21 02-OCT-09:09 11837.83 02-OCT-07:10 13457.54 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00 0.00
November 17832.21 01-NOV-09:09 11837.83 01-NOV-07:10 13457.54 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00 0.00
December 17832.21 01-DEC-10:09 11837.83 01-DEC-08:09 13457.54 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average             0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 17832.21   11837.83   13457.54   0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 17832.21   11837.83   13457.54   0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: PeakSpaceGainsMonthly

For: CORE_BOTTOM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 16014.58 02-JAN-10:09 10631.20 02-JAN-08:09 17206.63 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 0.00
February 16014.58 01-FEB-10:09 10631.20 01-FEB-08:09 17206.63 01-FEB-08:09 0.00 0.00 0.00 0.00 0.00 0.00
March 16014.58 01-MAR-10:09 10631.20 01-MAR-08:09 17206.63 01-MAR-08:09 0.00 0.00 0.00 0.00 0.00 0.00
April 16014.58 03-APR-09:09 10631.20 03-APR-07:10 17206.63 03-APR-07:10 0.00 0.00 0.00 0.00 0.00 0.00
May 16014.58 01-MAY-09:09 10631.20 01-MAY-07:10 17206.63 01-MAY-07:10 0.00 0.00 0.00 0.00 0.00 0.00
June 16014.58 01-JUN-09:09 10631.20 01-JUN-07:10 17206.63 01-JUN-07:10 0.00 0.00 0.00 0.00 0.00 0.00
July 16014.58 03-JUL-09:09 10631.20 03-JUL-07:10 17206.63 03-JUL-07:10 0.00 0.00 0.00 0.00 0.00 0.00
August 16014.58 01-AUG-09:09 10631.20 01-AUG-07:10 17206.63 01-AUG-07:10 0.00 0.00 0.00 0.00 0.00 0.00
September 16014.58 01-SEP-09:09 10631.20 01-SEP-07:10 17206.63 01-SEP-07:10 0.00 0.00 0.00 0.00 0.00 0.00
October 16014.58 02-OCT-09:09 10631.20 02-OCT-07:10 17206.63 02-OCT-07:10 0.00 0.00 0.00 0.00 0.00 0.00
November 16014.58 01-NOV-09:09 10631.20 01-NOV-07:10 17206.63 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 0.00
December 16014.58 01-DEC-10:09 10631.20 01-DEC-08:09 17206.63 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average             0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 16014.58   10631.20   17206.63   0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 16014.58   10631.20   17206.63   0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: PeakSpaceGainsMonthly

For: CORE_MID

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 16014.58 02-JAN-10:09 10631.20 02-JAN-08:09 17206.56 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 0.00
February 16014.58 01-FEB-10:09 10631.20 01-FEB-08:09 17206.56 01-FEB-08:09 0.00 0.00 0.00 0.00 0.00 0.00
March 16014.58 01-MAR-10:09 10631.20 01-MAR-08:09 17206.56 01-MAR-08:09 0.00 0.00 0.00 0.00 0.00 0.00
April 16014.58 03-APR-09:09 10631.20 03-APR-07:10 17206.56 03-APR-07:10 0.00 0.00 0.00 0.00 0.00 0.00
May 16014.58 01-MAY-09:09 10631.20 01-MAY-07:10 17206.56 01-MAY-07:10 0.00 0.00 0.00 0.00 0.00 0.00
June 16014.58 01-JUN-09:09 10631.20 01-JUN-07:10 17206.56 01-JUN-07:10 0.00 0.00 0.00 0.00 0.00 0.00
July 16014.58 03-JUL-09:09 10631.20 03-JUL-07:10 17206.56 03-JUL-07:10 0.00 0.00 0.00 0.00 0.00 0.00
August 16014.58 01-AUG-09:09 10631.20 01-AUG-07:10 17206.56 01-AUG-07:10 0.00 0.00 0.00 0.00 0.00 0.00
September 16014.58 01-SEP-09:09 10631.20 01-SEP-07:10 17206.56 01-SEP-07:10 0.00 0.00 0.00 0.00 0.00 0.00
October 16014.58 02-OCT-09:09 10631.20 02-OCT-07:10 17206.56 02-OCT-07:10 0.00 0.00 0.00 0.00 0.00 0.00
November 16014.58 01-NOV-09:09 10631.20 01-NOV-07:10 17206.56 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 0.00
December 16014.58 01-DEC-10:09 10631.20 01-DEC-08:09 17206.56 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average             0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 16014.58   10631.20   17206.56   0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 16014.58   10631.20   17206.56   0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: PeakSpaceGainsMonthly

For: CORE_TOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 16014.58 02-JAN-10:09 10631.20 02-JAN-08:09 17206.56 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 0.00
February 16014.58 01-FEB-10:09 10631.20 01-FEB-08:09 17206.56 01-FEB-08:09 0.00 0.00 0.00 0.00 0.00 0.00
March 16014.58 01-MAR-10:09 10631.20 01-MAR-08:09 17206.56 01-MAR-08:09 0.00 0.00 0.00 0.00 0.00 0.00
April 16014.58 03-APR-09:09 10631.20 03-APR-07:10 17206.56 03-APR-07:10 0.00 0.00 0.00 0.00 0.00 0.00
May 16014.58 01-MAY-09:09 10631.20 01-MAY-07:10 17206.56 01-MAY-07:10 0.00 0.00 0.00 0.00 0.00 0.00
June 16014.58 01-JUN-09:09 10631.20 01-JUN-07:10 17206.56 01-JUN-07:10 0.00 0.00 0.00 0.00 0.00 0.00
July 16014.58 03-JUL-09:09 10631.20 03-JUL-07:10 17206.56 03-JUL-07:10 0.00 0.00 0.00 0.00 0.00 0.00
August 16014.58 01-AUG-09:09 10631.20 01-AUG-07:10 17206.56 01-AUG-07:10 0.00 0.00 0.00 0.00 0.00 0.00
September 16014.58 01-SEP-09:09 10631.20 01-SEP-07:10 17206.56 01-SEP-07:10 0.00 0.00 0.00 0.00 0.00 0.00
October 16014.58 02-OCT-09:09 10631.20 02-OCT-07:10 17206.56 02-OCT-07:10 0.00 0.00 0.00 0.00 0.00 0.00
November 16014.58 01-NOV-09:09 10631.20 01-NOV-07:10 17206.56 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 0.00
December 16014.58 01-DEC-10:09 10631.20 01-DEC-08:09 17206.56 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average             0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 16014.58   10631.20   17206.56   0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 16014.58   10631.20   17206.56   0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_BOT_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 2010.79 02-JAN-10:09 1236.29 03-JAN-08:09 2160.55 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 438.84 07-JAN-18:10
February 2010.79 01-FEB-10:09 1303.01 01-FEB-08:09 2160.55 01-FEB-08:09 0.00 0.00 0.00 0.00 8.81 26-FEB-15:00 549.58 12-FEB-01:00
March 2010.79 01-MAR-10:09 1244.84 21-MAR-07:10 2160.55 01-MAR-08:09 0.00 0.00 0.00 0.00 11.61 30-MAR-16:00 363.08 22-MAR-03:00
April 2010.79 03-APR-09:09 1144.53 03-APR-07:10 2160.55 03-APR-07:10 0.00 0.00 0.00 0.00 19.79 16-APR-11:53 180.88 05-APR-05:00
May 2010.79 01-MAY-09:09 842.12 24-MAY-07:10 2160.55 01-MAY-07:10 0.00 0.00 0.00 0.00 24.74 07-MAY-12:17 141.95 10-MAY-04:00
June 2010.79 01-JUN-09:09 736.24 23-JUN-07:10 2160.55 01-JUN-07:10 0.00 0.00 0.00 0.00 79.11 11-JUN-15:00 102.50 07-JUN-03:00
July 2010.79 03-JUL-09:09 938.49 27-JUL-07:10 2160.55 03-JUL-07:10 0.00 0.00 0.00 0.00 74.80 08-JUL-18:53 76.17 28-JUL-22:00
August 2010.79 01-AUG-09:09 1098.41 24-AUG-07:10 2160.55 01-AUG-07:10 0.00 0.00 0.00 0.00 77.87 06-AUG-14:00 39.24 25-AUG-04:55
September 2010.79 01-SEP-09:09 1187.12 29-SEP-07:10 2160.55 01-SEP-07:10 0.00 0.00 0.00 0.00 29.06 17-SEP-15:00 97.90 30-SEP-19:00
October 2010.79 02-OCT-09:09 1332.07 30-OCT-07:10 2160.55 02-OCT-07:10 0.00 0.00 0.00 0.00 22.52 08-OCT-14:00 212.36 28-OCT-04:00
November 2010.79 01-NOV-09:09 1318.01 01-NOV-07:10 2160.55 01-NOV-07:10 0.00 0.00 0.00 0.00 4.47 19-NOV-15:00 305.45 07-NOV-02:00
December 2010.79 01-DEC-10:09 1239.01 06-DEC-08:09 2160.55 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 543.02 17-DEC-04:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 2010.79   736.24   2160.55   0.00 0.00 0.00 0.00 0.00   39.24  
Maximum of Months 2010.79   1332.07   2160.55   0.00 0.00 0.00 0.00 79.11   549.58  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_BOT_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 1295.83 02-JAN-10:09 783.06 03-JAN-08:09 1392.34 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 289.68 07-JAN-18:10
February 1295.83 01-FEB-10:09 839.68 01-FEB-08:09 1392.34 01-FEB-08:09 0.00 0.00 0.00 0.00 3.09 28-FEB-15:00 362.10 12-FEB-01:00
March 1295.83 01-MAR-10:09 795.51 21-MAR-07:10 1392.34 01-MAR-08:09 0.00 0.00 0.00 0.00 7.74 30-MAR-16:00 234.51 22-MAR-03:00
April 1295.83 03-APR-09:09 712.41 03-APR-07:10 1392.34 03-APR-07:10 0.00 0.00 0.00 0.00 9.59 16-APR-13:53 115.63 05-APR-05:00
May 1295.83 01-MAY-09:09 455.86 02-MAY-07:10 1392.34 01-MAY-07:10 0.00 0.00 0.00 0.00 14.18 29-MAY-18:00 94.67 10-MAY-04:00
June 1295.83 01-JUN-09:09 431.18 26-JUN-07:10 1392.34 01-JUN-07:10 0.00 0.00 0.00 0.00 47.92 11-JUN-15:00 67.85 07-JUN-03:00
July 1295.83 03-JUL-09:09 547.55 27-JUL-07:10 1392.34 03-JUL-07:10 0.00 0.00 0.00 0.00 49.97 08-JUL-18:53 47.50 28-JUL-22:00
August 1295.83 01-AUG-09:09 680.18 24-AUG-07:10 1392.34 01-AUG-07:10 0.00 0.00 0.00 0.00 50.36 06-AUG-13:57 23.10 25-AUG-04:55
September 1295.83 01-SEP-09:09 747.96 29-SEP-07:10 1392.34 01-SEP-07:10 0.00 0.00 0.00 0.00 20.15 17-SEP-15:00 62.91 29-SEP-05:00
October 1295.83 02-OCT-09:09 858.43 30-OCT-07:10 1392.34 02-OCT-07:10 0.00 0.00 0.00 0.00 12.33 09-OCT-15:43 138.35 28-OCT-04:00
November 1295.83 01-NOV-09:09 843.53 01-NOV-07:10 1392.34 01-NOV-07:10 0.00 0.00 0.00 0.00 6.70 19-NOV-15:00 201.23 07-NOV-02:00
December 1295.83 01-DEC-10:09 784.99 06-DEC-08:09 1392.34 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 352.60 17-DEC-04:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 1295.83   431.18   1392.34   0.00 0.00 0.00 0.00 0.00   23.10  
Maximum of Months 1295.83   858.43   1392.34   0.00 0.00 0.00 0.00 50.36   362.10  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_BOT_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 2010.83 02-JAN-10:09 1222.01 03-JAN-08:09 2160.58 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 434.38 07-JAN-18:10
February 2010.83 01-FEB-10:09 1303.03 01-FEB-08:09 2160.58 01-FEB-08:09 0.00 0.00 0.00 0.00 4.64 28-FEB-15:00 541.66 11-FEB-19:00
March 2010.83 01-MAR-10:09 1243.37 21-MAR-07:10 2160.58 01-MAR-08:09 0.00 0.00 0.00 0.00 11.58 30-MAR-16:00 352.71 22-MAR-03:00
April 2010.83 03-APR-09:09 1148.30 03-APR-07:10 2160.58 03-APR-07:10 0.00 0.00 0.00 0.00 9.73 16-APR-13:53 178.82 05-APR-05:00
May 2010.83 01-MAY-09:09 922.37 24-MAY-07:10 2160.58 01-MAY-07:10 0.00 0.00 0.00 0.00 20.76 29-MAY-18:00 141.59 10-MAY-04:00
June 2010.83 01-JUN-09:09 847.34 23-JUN-07:10 2160.58 01-JUN-07:10 0.00 0.00 0.00 0.00 76.12 11-JUN-15:00 103.17 07-JUN-03:00
July 2010.83 03-JUL-09:09 984.04 27-JUL-07:10 2160.58 03-JUL-07:10 0.00 0.00 0.00 0.00 72.40 08-JUL-18:53 75.51 28-JUL-22:00
August 2010.83 01-AUG-09:09 1109.07 24-AUG-07:10 2160.58 01-AUG-07:10 0.00 0.00 0.00 0.00 73.72 06-AUG-13:53 40.05 25-AUG-04:55
September 2010.83 01-SEP-09:09 1178.61 29-SEP-07:10 2160.58 01-SEP-07:10 0.00 0.00 0.00 0.00 20.25 17-SEP-15:18 94.35 29-SEP-05:00
October 2010.83 02-OCT-09:09 1332.10 30-OCT-07:10 2160.58 02-OCT-07:10 0.00 0.00 0.00 0.00 10.45 09-OCT-15:35 214.03 28-OCT-04:00
November 2010.83 01-NOV-09:09 1312.26 01-NOV-07:10 2160.58 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 315.79 07-NOV-02:00
December 2010.83 01-DEC-10:09 1223.40 06-DEC-08:09 2160.58 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 526.87 17-DEC-04:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 2010.83   847.34   2160.58   0.00 0.00 0.00 0.00 0.00   40.05  
Maximum of Months 2010.83   1332.10   2160.58   0.00 0.00 0.00 0.00 76.12   541.66  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_BOT_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 1295.83 02-JAN-10:09 799.48 03-JAN-08:09 1392.33 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 303.06 07-JAN-18:20
February 1295.83 01-FEB-10:09 839.68 01-FEB-08:09 1392.33 01-FEB-08:09 0.00 0.00 0.00 0.00 3.09 28-FEB-15:00 389.03 11-FEB-19:00
March 1295.83 01-MAR-10:09 806.10 21-MAR-07:10 1392.33 01-MAR-08:09 0.00 0.00 0.00 0.00 7.74 30-MAR-16:00 269.54 22-MAR-03:00
April 1295.83 03-APR-09:09 755.02 03-APR-07:10 1392.33 03-APR-07:10 0.00 0.00 0.00 0.00 6.48 16-APR-13:53 137.32 05-APR-05:00
May 1295.83 01-MAY-09:09 686.56 24-MAY-07:30 1392.33 01-MAY-07:10 0.00 0.00 0.00 0.00 15.43 29-MAY-17:57 102.86 10-MAY-04:00
June 1295.83 01-JUN-09:09 591.29 23-JUN-07:10 1392.33 01-JUN-07:10 0.00 0.00 0.00 0.00 46.01 25-JUN-16:04 79.42 07-JUN-03:00
July 1295.83 03-JUL-09:09 662.34 27-JUL-07:10 1392.33 03-JUL-07:10 0.00 0.00 0.00 0.00 46.72 08-JUL-19:10 60.60 28-JUL-22:00
August 1295.83 01-AUG-09:09 729.62 24-AUG-07:10 1392.33 01-AUG-07:10 0.00 0.00 0.00 0.00 49.16 06-AUG-13:53 38.29 29-AUG-02:00
September 1295.83 01-SEP-09:09 772.43 29-SEP-07:10 1392.33 01-SEP-07:10 0.00 0.00 0.00 0.00 14.65 24-SEP-13:00 73.24 30-SEP-19:00
October 1295.83 02-OCT-09:09 858.43 30-OCT-07:10 1392.33 02-OCT-07:10 0.00 0.00 0.00 0.00 6.75 09-OCT-15:35 158.98 28-OCT-04:00
November 1295.83 01-NOV-09:09 850.56 01-NOV-07:10 1392.33 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 229.45 07-NOV-02:00
December 1295.83 01-DEC-10:09 800.49 06-DEC-08:09 1392.33 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 401.00 17-DEC-04:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 1295.83   591.29   1392.33   0.00 0.00 0.00 0.00 0.00   38.29  
Maximum of Months 1295.83   858.43   1392.33   0.00 0.00 0.00 0.00 49.16   401.00  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_MID_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 2010.79 02-JAN-10:09 1238.36 03-JAN-08:09 2160.55 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 957.39 07-JAN-18:05
February 2010.79 01-FEB-10:09 1303.69 01-FEB-08:09 2160.55 01-FEB-08:09 0.00 0.00 0.00 0.00 52.90 26-FEB-13:10 1148.56 11-FEB-19:00
March 2010.79 01-MAR-10:09 1246.79 21-MAR-07:10 2160.55 01-MAR-08:09 0.00 0.00 0.00 0.00 32.18 11-MAR-16:00 747.00 22-MAR-03:00
April 2010.79 03-APR-09:09 1148.64 03-APR-07:10 2160.55 03-APR-07:10 0.00 0.00 0.00 0.00 51.72 16-APR-11:53 397.61 05-APR-05:00
May 2010.79 01-MAY-09:09 852.04 24-MAY-07:10 2160.55 01-MAY-07:10 0.00 0.00 0.00 0.00 66.46 07-MAY-11:53 317.17 10-MAY-04:00
June 2010.79 01-JUN-09:09 734.24 23-JUN-07:10 2160.55 01-JUN-07:10 0.00 0.00 0.00 0.00 197.50 11-JUN-15:00 232.86 07-JUN-03:00
July 2010.79 03-JUL-09:09 947.03 27-JUL-07:10 2160.55 03-JUL-07:10 0.00 0.00 0.00 0.00 177.62 08-JUL-18:53 163.65 28-JUL-22:00
August 2010.79 01-AUG-09:09 1103.52 24-AUG-07:10 2160.55 01-AUG-07:10 0.00 0.00 0.00 0.00 197.33 06-AUG-14:00 106.05 25-AUG-04:55
September 2010.79 01-SEP-09:09 1190.30 29-SEP-07:10 2160.55 01-SEP-07:10 0.00 0.00 0.00 0.00 80.93 17-SEP-15:00 210.65 29-SEP-05:00
October 2010.79 02-OCT-09:09 1332.13 30-OCT-07:10 2160.55 02-OCT-07:10 0.00 0.00 0.00 0.00 82.99 08-OCT-13:53 434.60 28-OCT-04:00
November 2010.79 01-NOV-09:09 1318.35 01-NOV-07:10 2160.55 01-NOV-07:10 0.00 0.00 0.00 0.00 33.27 19-NOV-15:00 634.56 07-NOV-02:00
December 2010.79 01-DEC-10:09 1241.01 06-DEC-08:09 2160.55 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 1084.65 17-DEC-04:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 2010.79   734.24   2160.55   0.00 0.00 0.00 0.00 0.00   106.05  
Maximum of Months 2010.79   1332.13   2160.55   0.00 0.00 0.00 0.00 197.50   1148.56  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_MID_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 1239.33 02-JAN-08:09 783.60 03-JAN-08:09 1392.34 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 635.79 07-JAN-18:05
February 1239.33 01-FEB-08:09 839.72 01-FEB-08:09 1392.34 01-FEB-08:09 0.00 0.00 0.00 0.00 14.87 26-FEB-14:53 766.86 11-FEB-19:00
March 1239.33 01-MAR-08:09 795.90 21-MAR-07:10 1392.34 01-MAR-08:09 0.00 0.00 0.00 0.00 18.41 11-MAR-16:00 494.16 22-MAR-03:00
April 1239.33 03-APR-07:10 713.91 03-APR-07:10 1392.34 03-APR-07:10 0.00 0.00 0.00 0.00 17.64 08-APR-17:02 264.60 05-APR-05:00
May 1239.33 01-MAY-07:10 454.38 02-MAY-07:10 1392.34 01-MAY-07:10 0.00 0.00 0.00 0.00 33.00 29-MAY-17:50 214.86 10-MAY-04:00
June 1239.33 01-JUN-07:10 429.34 26-JUN-07:10 1392.34 01-JUN-07:10 0.00 0.00 0.00 0.00 110.44 11-JUN-15:00 160.79 07-JUN-03:00
July 1239.33 03-JUL-07:10 550.44 27-JUL-07:10 1392.34 03-JUL-07:10 0.00 0.00 0.00 0.00 112.64 08-JUL-18:53 109.73 01-JUL-19:53
August 1239.33 01-AUG-07:10 681.81 24-AUG-07:10 1392.34 01-AUG-07:10 0.00 0.00 0.00 0.00 119.37 06-AUG-14:00 70.41 25-AUG-04:55
September 1239.33 01-SEP-07:10 748.74 29-SEP-07:10 1392.34 01-SEP-07:10 0.00 0.00 0.00 0.00 52.42 17-SEP-15:00 139.38 29-SEP-05:00
October 1239.33 02-OCT-07:10 858.44 30-OCT-07:10 1392.34 02-OCT-07:10 0.00 0.00 0.00 0.00 33.36 09-OCT-16:00 292.77 28-OCT-04:00
November 1239.33 01-NOV-07:10 843.71 01-NOV-07:10 1392.34 01-NOV-07:10 0.00 0.00 0.00 0.00 14.63 19-NOV-15:00 434.24 07-NOV-02:00
December 1239.33 01-DEC-08:09 785.50 06-DEC-08:09 1392.34 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 724.70 17-DEC-04:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 1239.33   429.34   1392.34   0.00 0.00 0.00 0.00 0.00   70.41  
Maximum of Months 1239.33   858.44   1392.34   0.00 0.00 0.00 0.00 119.37   766.86  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_MID_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 2010.83 02-JAN-10:09 1224.65 03-JAN-08:09 2160.58 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 971.08 07-JAN-18:05
February 2010.83 01-FEB-10:09 1303.71 01-FEB-08:09 2160.58 01-FEB-08:09 0.00 0.00 0.00 0.00 9.69 28-FEB-15:00 1201.77 11-FEB-19:00
March 2010.83 01-MAR-10:09 1245.37 21-MAR-07:10 2160.58 01-MAR-08:09 0.00 0.00 0.00 0.00 26.42 30-MAR-16:00 759.43 22-MAR-03:00
April 2010.83 03-APR-09:09 1152.28 03-APR-07:10 2160.58 03-APR-07:10 0.00 0.00 0.00 0.00 19.52 16-APR-14:10 400.32 05-APR-05:00
May 2010.83 01-MAY-09:09 930.16 24-MAY-07:10 2160.58 01-MAY-07:10 0.00 0.00 0.00 0.00 52.66 07-MAY-11:53 323.22 10-MAY-04:00
June 2010.83 01-JUN-09:09 856.93 23-JUN-07:10 2160.58 01-JUN-07:10 0.00 0.00 0.00 0.00 186.56 11-JUN-15:00 234.93 07-JUN-03:00
July 2010.83 03-JUL-09:09 991.19 27-JUL-07:10 2160.58 03-JUL-07:10 0.00 0.00 0.00 0.00 172.29 08-JUL-18:53 164.59 28-JUL-22:00
August 2010.83 01-AUG-09:09 1113.82 24-AUG-07:10 2160.58 01-AUG-07:10 0.00 0.00 0.00 0.00 175.25 06-AUG-13:57 109.27 25-AUG-04:55
September 2010.83 01-SEP-09:09 1182.09 29-SEP-07:10 2160.58 01-SEP-07:10 0.00 0.00 0.00 0.00 44.73 17-SEP-15:00 212.08 29-SEP-05:00
October 2010.83 02-OCT-09:09 1332.16 30-OCT-07:10 2160.58 02-OCT-07:10 0.00 0.00 0.00 0.00 20.92 10-OCT-16:00 467.60 28-OCT-04:00
November 2010.83 01-NOV-09:09 1312.81 01-NOV-07:10 2160.58 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 699.06 07-NOV-02:00
December 2010.83 01-DEC-10:09 1226.02 06-DEC-08:09 2160.58 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 1129.86 17-DEC-04:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 2010.83   856.93   2160.58   0.00 0.00 0.00 0.00 0.00   109.27  
Maximum of Months 2010.83   1332.16   2160.58   0.00 0.00 0.00 0.00 186.56   1201.77  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_MID_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 1295.83 02-JAN-10:09 799.62 03-JAN-08:09 1392.33 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 651.48 07-JAN-18:05
February 1295.83 01-FEB-10:09 839.72 01-FEB-08:09 1392.33 01-FEB-08:09 0.00 0.00 0.00 0.00 26.51 26-FEB-13:10 819.79 11-FEB-18:05
March 1295.83 01-MAR-10:09 806.21 21-MAR-07:10 1392.33 01-MAR-08:09 0.00 0.00 0.00 0.00 17.63 30-MAR-16:00 515.37 22-MAR-03:00
April 1295.83 03-APR-09:09 755.22 03-APR-07:10 1392.33 03-APR-07:10 0.00 0.00 0.00 0.00 27.78 16-APR-12:10 271.46 05-APR-05:00
May 1295.83 01-MAY-09:09 686.49 24-MAY-07:30 1392.33 01-MAY-07:10 0.00 0.00 0.00 0.00 40.90 07-MAY-11:53 223.29 10-MAY-04:00
June 1295.83 01-JUN-09:09 591.68 23-JUN-07:10 1392.33 01-JUN-07:10 0.00 0.00 0.00 0.00 104.55 11-JUN-14:57 167.14 07-JUN-03:00
July 1295.83 03-JUL-09:09 662.70 27-JUL-07:10 1392.33 03-JUL-07:10 0.00 0.00 0.00 0.00 105.72 08-JUL-19:10 114.37 28-JUL-22:00
August 1295.83 01-AUG-09:09 729.86 24-AUG-07:10 1392.33 01-AUG-07:10 0.00 0.00 0.00 0.00 119.79 06-AUG-14:00 77.89 25-AUG-04:55
September 1295.83 01-SEP-09:09 772.60 29-SEP-07:10 1392.33 01-SEP-07:10 0.00 0.00 0.00 0.00 41.24 24-SEP-12:50 141.73 29-SEP-05:00
October 1295.83 02-OCT-09:09 858.44 30-OCT-07:10 1392.33 02-OCT-07:10 0.00 0.00 0.00 0.00 31.32 08-OCT-13:53 306.31 28-OCT-04:00
November 1295.83 01-NOV-09:09 850.59 01-NOV-07:10 1392.33 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 450.32 07-NOV-02:00
December 1295.83 01-DEC-10:09 800.63 06-DEC-08:09 1392.33 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 746.74 17-DEC-04:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 1295.83   591.68   1392.33   0.00 0.00 0.00 0.00 0.00   77.89  
Maximum of Months 1295.83   858.44   1392.33   0.00 0.00 0.00 0.00 119.79   819.79  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_TOP_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 2010.79 02-JAN-10:09 1238.26 03-JAN-08:09 2160.55 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 1138.91 07-JAN-18:05
February 2010.79 01-FEB-10:09 1303.65 01-FEB-08:09 2160.55 01-FEB-08:09 0.00 0.00 0.00 0.00 100.36 26-FEB-13:10 1381.89 12-FEB-01:00
March 2010.79 01-MAR-10:09 1246.69 21-MAR-07:10 2160.55 01-MAR-08:09 0.00 0.00 0.00 0.00 44.15 11-MAR-16:00 843.55 22-MAR-04:55
April 2010.79 03-APR-09:09 1148.46 03-APR-07:10 2160.55 03-APR-07:10 0.00 0.00 0.00 0.00 66.62 16-APR-12:00 486.47 05-APR-04:53
May 2010.79 01-MAY-09:09 851.76 24-MAY-07:10 2160.55 01-MAY-07:10 0.00 0.00 0.00 0.00 75.12 07-MAY-11:57 369.21 10-MAY-04:00
June 2010.79 01-JUN-09:09 734.09 23-JUN-07:10 2160.55 01-JUN-07:10 0.00 0.00 0.00 0.00 223.61 11-JUN-15:00 290.37 07-JUN-03:00
July 2010.79 03-JUL-09:09 946.69 27-JUL-07:10 2160.55 03-JUL-07:10 0.00 0.00 0.00 0.00 191.19 08-JUL-18:53 203.61 01-JUL-19:53
August 2010.79 01-AUG-09:09 1103.28 24-AUG-07:10 2160.55 01-AUG-07:10 0.00 0.00 0.00 0.00 217.76 06-AUG-14:00 131.03 25-AUG-05:00
September 2010.79 01-SEP-09:09 1190.14 29-SEP-07:10 2160.55 01-SEP-07:10 0.00 0.00 0.00 0.00 89.58 17-SEP-15:00 240.14 29-SEP-05:00
October 2010.79 02-OCT-09:09 1332.13 30-OCT-07:10 2160.55 02-OCT-07:10 0.00 0.00 0.00 0.00 111.66 08-OCT-13:53 488.98 28-OCT-04:00
November 2010.79 01-NOV-09:09 1318.33 01-NOV-07:10 2160.55 01-NOV-07:10 0.00 0.00 0.00 0.00 112.68 19-NOV-15:00 751.01 30-NOV-22:05
December 2010.79 01-DEC-10:09 1240.90 06-DEC-08:09 2160.55 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 1159.00 17-DEC-04:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 2010.79   734.09   2160.55   0.00 0.00 0.00 0.00 0.00   131.03  
Maximum of Months 2010.79   1332.13   2160.55   0.00 0.00 0.00 0.00 223.61   1381.89  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_TOP_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 1295.83 02-JAN-10:09 783.54 03-JAN-08:09 1392.34 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 773.04 07-JAN-05:09
February 1295.83 01-FEB-10:09 839.70 01-FEB-08:09 1392.34 01-FEB-08:09 0.00 0.00 0.00 0.00 29.67 26-FEB-15:20 921.21 12-FEB-01:00
March 1295.83 01-MAR-10:09 795.84 21-MAR-07:10 1392.34 01-MAR-08:09 0.00 0.00 0.00 0.00 24.90 11-MAR-16:00 562.33 22-MAR-04:55
April 1295.83 03-APR-09:09 713.81 03-APR-07:10 1392.34 03-APR-07:10 0.00 0.00 0.00 0.00 23.61 16-APR-14:00 325.61 05-APR-04:53
May 1295.83 01-MAY-09:09 454.25 02-MAY-07:10 1392.34 01-MAY-07:10 0.00 0.00 0.00 0.00 35.51 29-MAY-17:42 251.42 10-MAY-04:00
June 1295.83 01-JUN-09:09 429.16 26-JUN-07:10 1392.34 01-JUN-07:10 0.00 0.00 0.00 0.00 136.78 25-JUN-16:06 201.26 07-JUN-03:00
July 1295.83 03-JUL-09:09 550.28 27-JUL-07:10 1392.34 03-JUL-07:10 0.00 0.00 0.00 0.00 130.43 08-JUL-19:10 147.36 01-JUL-19:53
August 1295.83 01-AUG-09:09 681.68 24-AUG-07:10 1392.34 01-AUG-07:10 0.00 0.00 0.00 0.00 146.78 06-AUG-14:00 87.43 25-AUG-05:00
September 1295.83 01-SEP-09:09 748.66 29-SEP-07:10 1392.34 01-SEP-07:10 0.00 0.00 0.00 0.00 58.19 17-SEP-15:00 159.62 29-SEP-05:00
October 1295.83 02-OCT-09:09 858.44 30-OCT-07:10 1392.34 02-OCT-07:10 0.00 0.00 0.00 0.00 42.70 09-OCT-16:00 331.26 28-OCT-04:00
November 1295.83 01-NOV-09:09 843.71 01-NOV-07:10 1392.34 01-NOV-07:10 0.00 0.00 0.00 0.00 65.48 19-NOV-15:00 500.15 30-NOV-22:05
December 1295.83 01-DEC-10:09 785.45 06-DEC-08:09 1392.34 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 774.89 17-DEC-04:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 1295.83   429.16   1392.34   0.00 0.00 0.00 0.00 0.00   87.43  
Maximum of Months 1295.83   858.44   1392.34   0.00 0.00 0.00 0.00 146.78   921.21  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_TOP_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 2010.83 02-JAN-10:09 1224.55 03-JAN-08:09 2160.58 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 1159.53 07-JAN-05:10
February 2010.83 01-FEB-10:09 1303.67 01-FEB-08:09 2160.58 01-FEB-08:09 0.00 0.00 0.00 0.00 10.56 28-FEB-15:00 1417.24 11-FEB-18:05
March 2010.83 01-MAR-10:09 1245.27 21-MAR-07:10 2160.58 01-MAR-08:09 0.00 0.00 0.00 0.00 31.63 30-MAR-16:00 843.54 22-MAR-05:00
April 2010.83 03-APR-09:09 1152.10 03-APR-07:10 2160.58 03-APR-07:10 0.00 0.00 0.00 0.00 33.16 16-APR-14:00 489.95 05-APR-04:53
May 2010.83 01-MAY-09:09 929.90 24-MAY-07:10 2160.58 01-MAY-07:10 0.00 0.00 0.00 0.00 57.41 07-MAY-12:00 378.03 10-MAY-04:00
June 2010.83 01-JUN-09:09 856.48 23-JUN-07:10 2160.58 01-JUN-07:10 0.00 0.00 0.00 0.00 211.24 11-JUN-15:00 293.35 07-JUN-03:00
July 2010.83 03-JUL-09:09 990.86 27-JUL-07:10 2160.58 03-JUL-07:10 0.00 0.00 0.00 0.00 186.81 08-JUL-19:10 205.16 01-JUL-19:53
August 2010.83 01-AUG-09:09 1113.59 24-AUG-07:10 2160.58 01-AUG-07:10 0.00 0.00 0.00 0.00 214.54 06-AUG-13:57 136.14 25-AUG-05:00
September 2010.83 01-SEP-09:09 1181.94 29-SEP-07:10 2160.58 01-SEP-07:10 0.00 0.00 0.00 0.00 49.99 17-SEP-15:00 242.25 29-SEP-05:00
October 2010.83 02-OCT-09:09 1332.15 30-OCT-07:10 2160.58 02-OCT-07:10 0.00 0.00 0.00 0.00 25.52 10-OCT-16:00 536.70 28-OCT-04:00
November 2010.83 01-NOV-09:09 1312.80 01-NOV-07:10 2160.58 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 814.48 07-NOV-02:00
December 2010.83 01-DEC-10:09 1225.92 06-DEC-08:09 2160.58 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 1209.78 17-DEC-04:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 2010.83   856.48   2160.58   0.00 0.00 0.00 0.00 0.00   136.14  
Maximum of Months 2010.83   1332.15   2160.58   0.00 0.00 0.00 0.00 214.54   1417.24  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_TOP_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 1295.83 02-JAN-10:09 799.55 03-JAN-08:09 1392.33 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 776.66 07-JAN-18:05
February 1295.83 01-FEB-10:09 839.70 01-FEB-08:09 1392.33 01-FEB-08:09 0.00 0.00 0.00 0.00 48.98 26-FEB-13:10 983.49 11-FEB-18:05
March 1295.83 01-MAR-10:09 806.15 21-MAR-07:10 1392.33 01-MAR-08:09 0.00 0.00 0.00 0.00 21.24 30-MAR-16:00 581.08 22-MAR-03:00
April 1295.83 03-APR-09:09 755.10 03-APR-07:10 1392.33 03-APR-07:10 0.00 0.00 0.00 0.00 36.23 16-APR-12:00 335.00 05-APR-04:53
May 1295.83 01-MAY-09:09 686.39 24-MAY-07:30 1392.33 01-MAY-07:10 0.00 0.00 0.00 0.00 49.40 07-MAY-11:57 263.04 10-MAY-04:00
June 1295.83 01-JUN-09:09 591.42 23-JUN-07:10 1392.33 01-JUN-07:10 0.00 0.00 0.00 0.00 126.11 11-JUN-15:14 208.36 07-JUN-03:00
July 1295.83 03-JUL-09:09 662.50 27-JUL-07:10 1392.33 03-JUL-07:10 0.00 0.00 0.00 0.00 134.68 08-JUL-19:10 142.60 01-JUL-19:53
August 1295.83 01-AUG-09:09 729.72 24-AUG-07:10 1392.33 01-AUG-07:10 0.00 0.00 0.00 0.00 149.41 06-AUG-14:00 99.50 29-AUG-01:53
September 1295.83 01-SEP-09:09 772.51 29-SEP-07:10 1392.33 01-SEP-07:10 0.00 0.00 0.00 0.00 48.74 24-SEP-12:43 164.09 29-SEP-05:00
October 1295.83 02-OCT-09:09 858.44 30-OCT-07:10 1392.33 02-OCT-07:10 0.00 0.00 0.00 0.00 41.60 08-OCT-13:53 352.63 28-OCT-04:00
November 1295.83 01-NOV-09:09 850.58 01-NOV-07:10 1392.33 01-NOV-07:10 0.00 0.00 0.00 0.00 2.82 19-NOV-15:00 521.86 07-NOV-02:00
December 1295.83 01-DEC-10:09 800.56 06-DEC-08:09 1392.33 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 822.17 17-DEC-04:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 1295.83   591.42   1392.33   0.00 0.00 0.00 0.00 0.00   99.50  
Maximum of Months 1295.83   858.44   1392.33   0.00 0.00 0.00 0.00 149.41   983.49  



Table of Contents

Report: PeakSpaceGainsMonthly

For: DATACENTER_BOT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 232.27 02-JAN-10:09 284.97 02-JAN-08:09 1948.61 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00 0.00
February 232.27 01-FEB-10:09 284.97 01-FEB-08:09 3897.21 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00 0.00
March 232.27 01-MAR-10:09 284.97 01-MAR-08:09 7794.42 31-MAR-23:10 0.00 0.00 0.00 0.00 0.00 0.00
April 232.27 03-APR-09:09 284.97 03-APR-07:10 7794.42 01-APR-00:10 0.00 0.00 0.00 0.00 0.00 0.00
May 232.27 01-MAY-09:09 284.97 01-MAY-07:10 3897.21 31-MAY-23:10 0.00 0.00 0.00 0.00 0.00 0.00
June 232.27 01-JUN-09:09 284.97 01-JUN-07:10 5845.82 30-JUN-23:10 0.00 0.00 0.00 0.00 0.00 0.00
July 232.27 03-JUL-09:09 284.97 03-JUL-07:10 7794.42 31-JUL-23:10 0.00 0.00 0.00 0.00 0.00 0.00
August 232.27 01-AUG-09:09 284.97 01-AUG-07:10 7794.42 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00 0.00
September 232.27 01-SEP-09:09 284.97 01-SEP-07:10 3897.21 30-SEP-23:10 0.00 0.00 0.00 0.00 0.00 0.00
October 232.27 02-OCT-09:09 284.97 02-OCT-07:10 5845.82 31-OCT-23:10 0.00 0.00 0.00 0.00 0.00 0.00
November 232.27 01-NOV-09:09 284.97 01-NOV-07:10 5845.82 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00 0.00
December 232.27 01-DEC-10:09 284.97 01-DEC-08:09 7794.42 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average             0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 232.27   284.97   1948.61   0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 232.27   284.97   7794.42   0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: PeakSpaceGainsMonthly

For: DATACENTER_MID_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 232.27 02-JAN-10:09 284.97 02-JAN-08:09 1948.61 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00 0.00
February 232.27 01-FEB-10:09 284.97 01-FEB-08:09 3897.21 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00 0.00
March 232.27 01-MAR-10:09 284.97 01-MAR-08:09 7794.42 31-MAR-23:10 0.00 0.00 0.00 0.00 0.00 0.00
April 232.27 03-APR-09:09 284.97 03-APR-07:10 7794.42 01-APR-00:10 0.00 0.00 0.00 0.00 0.00 0.00
May 232.27 01-MAY-09:09 284.97 01-MAY-07:10 3897.21 31-MAY-23:10 0.00 0.00 0.00 0.00 0.00 0.00
June 232.27 01-JUN-09:09 284.97 01-JUN-07:10 5845.82 30-JUN-23:10 0.00 0.00 0.00 0.00 0.00 0.00
July 232.27 03-JUL-09:09 284.97 03-JUL-07:10 7794.42 31-JUL-23:10 0.00 0.00 0.00 0.00 0.00 0.00
August 232.27 01-AUG-09:09 284.97 01-AUG-07:10 7794.42 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00 0.00
September 232.27 01-SEP-09:09 284.97 01-SEP-07:10 3897.21 30-SEP-23:10 0.00 0.00 0.00 0.00 0.00 0.00
October 232.27 02-OCT-09:09 284.97 02-OCT-07:10 5845.82 31-OCT-23:10 0.00 0.00 0.00 0.00 0.00 0.00
November 232.27 01-NOV-09:09 284.97 01-NOV-07:10 5845.82 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00 0.00
December 232.27 01-DEC-10:09 284.97 01-DEC-08:09 7794.42 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average             0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 232.27   284.97   1948.61   0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 232.27   284.97   7794.42   0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: PeakSpaceGainsMonthly

For: DATACENTER_TOP_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 232.27 02-JAN-10:09 284.97 02-JAN-08:09 1948.61 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00 0.00
February 232.27 01-FEB-10:09 284.97 01-FEB-08:09 3897.21 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00 0.00
March 232.27 01-MAR-10:09 284.97 01-MAR-08:09 7794.42 31-MAR-23:10 0.00 0.00 0.00 0.00 0.00 0.00
April 232.27 03-APR-09:09 284.97 03-APR-07:10 7794.42 01-APR-00:10 0.00 0.00 0.00 0.00 0.00 0.00
May 232.27 01-MAY-09:09 284.97 01-MAY-07:10 3897.21 31-MAY-23:10 0.00 0.00 0.00 0.00 0.00 0.00
June 232.27 01-JUN-09:09 284.97 01-JUN-07:10 5845.82 30-JUN-23:10 0.00 0.00 0.00 0.00 0.00 0.00
July 232.27 03-JUL-09:09 284.97 03-JUL-07:10 7794.42 31-JUL-23:10 0.00 0.00 0.00 0.00 0.00 0.00
August 232.27 01-AUG-09:09 284.97 01-AUG-07:10 7794.42 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00 0.00
September 232.27 01-SEP-09:09 284.97 01-SEP-07:10 3897.21 30-SEP-23:10 0.00 0.00 0.00 0.00 0.00 0.00
October 232.27 02-OCT-09:09 284.97 02-OCT-07:10 5845.82 31-OCT-23:10 0.00 0.00 0.00 0.00 0.00 0.00
November 232.27 01-NOV-09:09 284.97 01-NOV-07:10 5845.82 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00 0.00
December 232.27 01-DEC-10:09 284.97 01-DEC-08:09 7794.42 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average             0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 232.27   284.97   1948.61   0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 232.27   284.97   7794.42   0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: PeakSpaceGainsMonthly

For: DATACENTER_BASEMENT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 5027.92 02-JAN-10:09 3337.76 02-JAN-08:09 94908.13 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00 0.00
February 5027.92 01-FEB-10:09 3337.76 01-FEB-08:09 189816.26 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00 0.00
March 5027.92 01-MAR-10:09 3337.76 01-MAR-08:09 379632.52 31-MAR-23:10 0.00 0.00 0.00 0.00 0.00 0.00
April 5027.92 03-APR-09:09 3337.76 03-APR-07:10 379632.52 01-APR-00:10 0.00 0.00 0.00 0.00 0.00 0.00
May 5027.92 01-MAY-09:09 3337.76 01-MAY-07:10 189816.26 31-MAY-23:10 0.00 0.00 0.00 0.00 0.00 0.00
June 5027.92 01-JUN-09:09 3337.76 01-JUN-07:10 284724.39 30-JUN-23:10 0.00 0.00 0.00 0.00 0.00 0.00
July 5027.92 03-JUL-09:09 3337.76 03-JUL-07:10 379632.52 31-JUL-23:10 0.00 0.00 0.00 0.00 0.00 0.00
August 5027.92 01-AUG-09:09 3337.76 01-AUG-07:10 379632.52 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00 0.00
September 5027.92 01-SEP-09:09 3337.76 01-SEP-07:10 189816.26 30-SEP-23:10 0.00 0.00 0.00 0.00 0.00 0.00
October 5027.92 02-OCT-09:09 3337.76 02-OCT-07:10 284724.39 31-OCT-23:10 0.00 0.00 0.00 0.00 0.00 0.00
November 5027.92 01-NOV-09:09 3337.76 01-NOV-07:10 284724.39 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00 0.00
December 5027.92 01-DEC-10:09 3337.76 01-DEC-08:09 379632.52 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average             0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 5027.92   3337.76   94908.13   0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5027.92   3337.76   379632.52   0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: PeakSpaceGainsMonthly

For: GROUNDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 954.91 07-JAN-18:10
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4.45 28-FEB-15:00 1199.73 12-FEB-01:00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 19.22 30-MAR-16:00 770.91 22-MAR-03:00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 30.66 16-APR-14:00 381.63 05-APR-05:00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 48.62 07-MAY-11:53 304.23 10-MAY-04:00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 159.69 11-JUN-15:00 206.40 07-JUN-03:00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 155.70 08-JUL-18:53 148.82 28-JUL-24:00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 165.44 06-AUG-14:00 92.38 25-AUG-04:55
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 55.96 17-SEP-15:00 208.73 29-SEP-05:00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 30.81 09-OCT-16:00 448.17 28-OCT-04:00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 655.84 07-NOV-02:00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 1168.27 17-DEC-04:00
                       
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00        
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00   92.38  
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 165.44   1199.73  



Table of Contents

Report: PeakSpaceGainsMonthly

For: MIDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 1629.85 07-JAN-18:05
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 30.04 26-FEB-15:00 2050.93 12-FEB-01:00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 36.01 11-MAR-16:00 1316.51 22-MAR-03:00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 62.42 16-APR-11:53 671.11 05-APR-05:00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 97.50 07-MAY-12:00 542.10 10-MAY-04:00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 302.18 11-JUN-15:00 368.92 07-JUN-03:00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 290.06 08-JUL-18:53 261.74 28-JUL-24:00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 308.88 06-AUG-13:53 173.26 25-AUG-05:00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 114.25 17-SEP-15:00 370.26 29-SEP-05:00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 77.83 09-OCT-16:00 764.31 28-OCT-04:00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 35.19 19-NOV-15:00 1126.88 21-NOV-04:00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 1964.99 17-DEC-04:00
                       
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00        
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00   173.26  
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 308.88   2050.93  



Table of Contents

Report: PeakSpaceGainsMonthly

For: TOPFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 1768.66 07-JAN-18:05
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 33.50 26-FEB-14:40 2108.93 11-FEB-18:05
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 30.80 11-MAR-16:00 1302.75 22-MAR-03:00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 31.83 16-APR-14:00 729.54 05-APR-04:53
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 57.25 29-MAY-18:00 546.36 10-MAY-04:00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 245.72 11-JUN-15:00 422.90 07-JUN-03:00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 253.10 08-JUL-18:53 305.28 01-JUL-19:53
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 245.15 06-AUG-14:00 182.50 25-AUG-04:55
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 68.42 17-SEP-15:00 350.87 29-SEP-05:00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 59.31 08-OCT-13:53 776.64 28-OCT-04:00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 104.12 19-NOV-15:00 1140.75 30-NOV-22:05
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 1823.88 17-DEC-04:00
                       
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00        
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00   182.50  
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 253.10   2108.93  



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: BASEMENT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 91435.55 23-JAN-05:01 0.00 13152.78 134575.44 0.00 0.00 0.00 0.00 0.00 0.00
February 94143.23 21-FEB-04:03 0.00 1973.16 40372.63 0.00 0.00 0.00 0.00 0.00 0.00
March 91400.92 27-MAR-03:02 0.00 2630.88 53830.18 0.00 0.00 0.00 0.00 0.00 0.00
April 88155.65 11-APR-04:12 0.00 5261.11 53830.18 0.00 0.00 0.00 0.00 0.00 0.00
May 87863.66 10-MAY-04:03 0.00 5261.11 53830.18 0.00 0.00 0.00 0.00 0.00 0.00
June 85670.03 09-JUN-04:03 0.00 5261.11 53830.18 0.00 0.00 0.00 0.00 0.00 0.00
July 80181.04 03-JUL-03:02 0.00 2630.88 53830.18 0.00 0.00 0.00 0.00 0.00 0.00
August 71182.15 14-AUG-03:02 0.00 3946.33 80745.26 0.00 0.00 0.00 0.00 0.00 0.00
September 87711.09 29-SEP-04:02 0.00 6576.39 67287.72 0.00 0.00 0.00 0.00 0.00 0.00
October 93418.51 30-OCT-03:13 0.00 1973.16 40372.63 0.00 0.00 0.00 0.00 0.00 0.00
November 94806.51 13-NOV-04:02 0.00 3288.60 67287.72 0.00 0.00 0.00 0.00 0.00 0.00
December 98197.18 26-DEC-04:01 0.00 5919.49 121117.90 0.00 0.00 0.00 0.00 0.00 0.00
                       
Annual Sum or Average           0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 71182.15   0.00 1973.16 40372.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 98197.18   0.00 13152.78 134575.44 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: CORE_BOTTOM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 81106.41 02-JAN-05:01 0.00 9449.70 47501.16 0.00 0.00 0.00 0.00 0.00 0.00
February 76674.03 28-FEB-05:03 0.00 4724.85 23750.58 0.00 0.00 0.00 0.00 0.00 0.00
March 77387.91 14-MAR-03:02 0.00 2953.40 29688.23 0.00 0.00 0.00 0.00 0.00 0.00
April 77837.70 04-APR-03:02 0.00 2953.40 29688.23 0.00 0.00 0.00 0.00 0.00 0.00
May 78119.10 22-MAY-03:02 0.00 2953.40 29688.23 0.00 0.00 0.00 0.00 0.00 0.00
June 74638.12 19-JUN-05:04 8061.19 5906.06 38236.95 0.00 0.00 0.00 0.00 0.00 0.00
July 77136.42 03-JUL-05:04 8061.19 5906.06 38236.95 0.00 0.00 0.00 0.00 0.00 0.00
August 70752.83 28-AUG-05:04 8061.19 5906.06 38236.95 0.00 0.00 0.00 0.00 0.00 0.00
September 81262.16 18-SEP-03:02 0.00 2362.72 23750.58 0.00 0.00 0.00 0.00 0.00 0.00
October 80411.14 02-OCT-03:02 0.00 3544.08 35625.87 0.00 0.00 0.00 0.00 0.00 0.00
November 83792.51 13-NOV-04:02 0.00 2953.40 29688.23 0.00 0.00 0.00 0.00 0.00 0.00
December 82309.90 26-DEC-04:01 0.00 5316.12 53438.81 0.00 0.00 0.00 0.00 0.00 0.00
                       
Annual Sum or Average           0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 70752.83   0.00 2362.72 23750.58 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 83792.51   8061.19 9449.70 53438.81 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: CORE_MID

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 21330.00 31-JAN-17:00 15316.26 10631.20 17206.56 0.00 0.00 0.00 0.00 0.00 0.00
February 68184.15 28-FEB-06:02 8061.19 5906.06 38236.81 0.00 0.00 0.00 0.00 0.00 0.00
March 71687.85 15-MAR-05:02 8061.19 5906.06 38236.81 0.00 0.00 0.00 0.00 0.00 0.00
April 72587.25 04-APR-05:02 8061.19 5906.06 38236.81 0.00 0.00 0.00 0.00 0.00 0.00
May 71652.87 13-MAY-05:02 8061.19 5906.06 38236.81 0.00 0.00 0.00 0.00 0.00 0.00
June 72217.58 07-JUN-04:03 0.00 4724.85 23750.49 0.00 0.00 0.00 0.00 0.00 0.00
July 72658.43 01-JUL-05:04 8061.19 5906.06 38236.81 0.00 0.00 0.00 0.00 0.00 0.00
August 72247.67 31-AUG-05:04 8061.19 5906.06 38236.81 0.00 0.00 0.00 0.00 0.00 0.00
September 71114.08 18-SEP-04:03 0.00 3543.64 17812.87 0.00 0.00 0.00 0.00 0.00 0.00
October 72152.68 05-OCT-05:02 8061.19 5906.06 38236.81 0.00 0.00 0.00 0.00 0.00 0.00
November 69334.62 06-NOV-06:03 6448.95 4724.85 30589.44 0.00 0.00 0.00 0.00 0.00 0.00
December 66368.82 13-DEC-06:02 8061.19 5906.06 38236.81 0.00 0.00 0.00 0.00 0.00 0.00
                       
Annual Sum or Average           0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 21330.00   0.00 3543.64 17206.56 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 72658.43   15316.26 10631.20 38236.81 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: CORE_TOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 18890.02 20-JAN-17:00 15316.26 10631.20 17206.56 0.00 0.00 0.00 0.00 0.00 0.00
February 30210.25 28-FEB-17:00 15316.26 10631.20 17206.56 0.00 0.00 0.00 0.00 0.00 0.00
March 70494.39 31-MAR-05:04 8061.19 5906.06 38236.81 0.00 0.00 0.00 0.00 0.00 0.00
April 70178.30 19-APR-05:02 8061.19 5906.06 38236.81 0.00 0.00 0.00 0.00 0.00 0.00
May 70338.42 09-MAY-05:02 8061.19 5906.06 38236.81 0.00 0.00 0.00 0.00 0.00 0.00
June 72696.20 19-JUN-03:02 0.00 2953.40 29688.11 0.00 0.00 0.00 0.00 0.00 0.00
July 72472.86 27-JUL-05:04 8061.19 5906.06 38236.81 0.00 0.00 0.00 0.00 0.00 0.00
August 72821.55 08-AUG-05:04 8061.19 5906.06 38236.81 0.00 0.00 0.00 0.00 0.00 0.00
September 73098.60 02-SEP-05:04 8061.19 5906.06 38236.81 0.00 0.00 0.00 0.00 0.00 0.00
October 68260.30 11-OCT-05:03 6448.95 4724.85 30589.44 0.00 0.00 0.00 0.00 0.00 0.00
November 45105.36 04-NOV-05:03 6448.95 4724.85 30589.44 0.00 0.00 0.00 0.00 0.00 0.00
December 26802.25 13-DEC-17:00 15316.26 10631.20 17206.56 0.00 0.00 0.00 0.00 0.00 0.00
                       
Annual Sum or Average           0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 18890.02   0.00 2953.40 17206.56 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 73098.60   15316.26 10631.20 38236.81 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_BOT_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 3160.46 31-JAN-15:00 2010.79 687.31 2160.55 0.00 0.00 0.00 0.00 0.00 7.24
February 5312.33 28-FEB-15:00 2010.79 635.12 2160.55 0.00 0.00 0.00 0.00 4.64 0.00
March 6551.65 30-MAR-14:00 2010.79 635.12 2160.55 0.00 0.00 0.00 0.00 9.19 0.00
April 7285.06 19-APR-05:02 1012.16 741.56 4801.23 0.00 0.00 0.00 0.00 0.00 8.94
May 10663.23 19-MAY-14:07 5769.33 1905.37 6481.66 0.00 0.00 0.00 0.00 12.32 0.00
June 10595.77 16-JUN-05:03 809.73 593.25 3840.98 0.00 0.00 0.00 0.00 0.00 5.97
July 14504.03 16-JUL-16:21 708.51 247.02 5041.29 0.00 0.00 0.00 0.00 25.81 0.00
August 12918.85 06-AUG-17:42 0.00 211.73 3355.02 0.00 0.00 0.00 0.00 40.99 0.00
September 10805.02 25-SEP-05:03 809.73 593.25 3840.98 0.00 0.00 0.00 0.00 0.00 0.00
October 10451.67 02-OCT-05:03 809.73 593.25 3840.98 0.00 0.00 0.00 0.00 0.00 9.51
November 4993.90 02-NOV-13:50 2010.79 635.12 2160.55 0.00 0.00 0.00 0.00 0.00 1.83
December 4874.81 13-DEC-12:00 1923.11 671.64 2160.55 0.00 0.00 0.00 0.00 0.00 7.19
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 3160.46   0.00 211.73 2160.55 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 14504.03   5769.33 1905.37 6481.66 0.00 0.00 0.00 0.00 40.99 9.51



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_BOT_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 2472.48 31-JAN-10:30 2591.66 818.60 2784.68 0.00 0.00 0.00 0.00 0.00 13.94
February 6111.45 27-FEB-09:40 1239.33 409.30 1392.34 0.00 0.00 0.00 0.00 0.00 15.81
March 6762.15 14-MAR-09:30 1295.83 409.30 1392.34 0.00 0.00 0.00 0.00 0.00 9.02
April 10712.24 16-APR-09:43 195.68 68.22 1392.34 0.00 0.00 0.00 0.00 0.00 15.36
May 14851.42 07-MAY-08:43 260.91 90.96 1856.46 0.00 0.00 0.00 0.00 0.00 19.82
June 15069.06 04-JUN-08:53 260.91 90.96 1856.46 0.00 0.00 0.00 0.00 0.00 6.97
July 15041.53 09-JUL-09:02 260.91 90.96 1856.46 0.00 0.00 0.00 0.00 0.00 9.11
August 15302.35 27-AUG-09:42 326.14 113.70 2320.57 0.00 0.00 0.00 0.00 0.00 0.99
September 14691.60 24-SEP-09:53 260.91 90.96 1856.46 0.00 0.00 0.00 0.00 0.00 2.80
October 9665.96 09-OCT-09:33 195.68 68.22 1392.34 0.00 0.00 0.00 0.00 0.00 19.67
November 5683.29 06-NOV-09:30 1239.33 409.30 1392.34 0.00 0.00 0.00 0.00 0.00 15.60
December 3190.90 11-DEC-10:30 1295.83 409.30 1392.34 0.00 0.00 0.00 0.00 0.00 11.53
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 2472.48   195.68 68.22 1392.34 0.00 0.00 0.00 0.00 0.00 0.99
Maximum of Months 15302.35   2591.66 818.60 2784.68 0.00 0.00 0.00 0.00 0.00 19.82



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_BOT_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 8514.63 23-JAN-14:30 2010.83 635.14 2160.58 0.00 0.00 0.00 0.00 0.00 46.46
February 17299.89 26-FEB-13:53 404.87 141.16 2880.78 0.00 0.00 0.00 0.00 0.00 25.68
March 12981.49 30-MAR-13:30 2010.83 635.14 2160.58 0.00 0.00 0.00 0.00 7.87 0.00
April 12850.77 12-APR-13:20 4021.67 1270.27 4321.17 0.00 0.00 0.00 0.00 5.22 0.00
May 13017.00 19-MAY-14:07 5769.46 1905.41 6481.75 0.00 0.00 0.00 0.00 12.13 0.00
June 12102.57 24-JUN-05:02 1012.19 741.58 4801.30 0.00 0.00 0.00 0.00 0.00 5.20
July 16938.91 16-JUL-15:02 607.31 211.73 4321.17 0.00 0.00 0.00 0.00 39.80 0.00
August 17057.58 27-AUG-13:02 404.87 141.16 2880.78 0.00 0.00 0.00 0.00 36.70 0.00
September 17490.52 24-SEP-12:32 404.87 141.16 2880.78 0.00 0.00 0.00 0.00 9.53 0.00
October 18033.72 09-OCT-14:12 506.09 176.44 3600.97 0.00 0.00 0.00 0.00 0.00 2.91
November 17711.08 11-NOV-13:53 404.87 141.16 2880.78 0.00 0.00 0.00 0.00 0.00 58.77
December 17001.28 10-DEC-14:02 404.87 141.16 2880.78 0.00 0.00 0.00 0.00 0.00 39.14
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 8514.63   404.87 141.16 2160.58 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 18033.72   5769.46 1905.41 6481.75 0.00 0.00 0.00 0.00 39.80 58.77



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_BOT_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 4634.21 23-JAN-16:30 1239.33 409.30 1392.33 0.00 0.00 0.00 0.00 0.00 26.07
February 15748.19 26-FEB-15:53 260.91 90.96 1856.44 0.00 0.00 0.00 0.00 0.00 15.76
March 17806.43 26-MAR-18:03 0.00 90.96 1441.39 0.00 0.00 0.00 0.00 0.00 36.74
April 19414.22 09-APR-16:52 326.14 113.70 2320.55 0.00 0.00 0.00 0.00 0.00 9.68
May 19821.88 21-MAY-17:32 0.00 113.70 1801.74 0.00 0.00 0.00 0.00 0.00 10.76
June 19323.97 25-JUN-16:02 326.14 113.70 2320.55 0.00 0.00 0.00 0.00 42.30 0.00
July 21299.66 16-JUL-16:21 456.59 159.19 3248.78 0.00 0.00 0.00 0.00 12.45 0.00
August 20475.59 06-AUG-17:42 0.00 136.45 2162.09 0.00 0.00 0.00 0.00 20.24 0.00
September 18259.41 03-SEP-15:32 260.91 90.96 1856.44 0.00 0.00 0.00 0.00 6.23 0.00
October 19026.28 08-OCT-15:13 260.91 90.96 1856.44 0.00 0.00 0.00 0.00 1.02 0.00
November 18739.24 11-NOV-15:53 260.91 90.96 1856.44 0.00 0.00 0.00 0.00 0.00 24.51
December 15799.51 13-DEC-04:02 0.00 238.98 2402.32 0.00 0.00 0.00 0.00 0.00 49.87
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 4634.21   0.00 90.96 1392.33 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 21299.66   1239.33 409.30 3248.78 0.00 0.00 0.00 0.00 42.30 49.87



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_MID_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 2038.35 31-JAN-17:00 1923.11 921.05 2160.55 0.00 0.00 0.00 0.00 0.00 14.24
February 3558.94 28-FEB-15:00 2010.79 635.12 2160.55 0.00 0.00 0.00 0.00 9.69 0.00
March 5534.11 30-MAR-15:50 1923.11 635.12 2160.55 0.00 0.00 0.00 0.00 26.14 0.00
April 6119.35 19-APR-05:02 1012.16 741.56 4801.23 0.00 0.00 0.00 0.00 0.00 21.25
May 9745.97 19-MAY-05:02 1012.16 741.56 4801.23 0.00 0.00 0.00 0.00 0.00 0.00
June 10900.18 26-JUN-05:02 1012.16 741.56 4801.23 0.00 0.00 0.00 0.00 0.00 4.50
July 10781.67 17-JUL-03:02 0.00 370.83 3727.80 0.00 0.00 0.00 0.00 0.00 37.22
August 11212.61 04-AUG-03:02 0.00 370.83 3727.80 0.00 0.00 0.00 0.00 0.00 6.36
September 9964.62 28-SEP-05:03 809.73 593.25 3840.98 0.00 0.00 0.00 0.00 0.00 9.72
October 9702.37 19-OCT-05:02 1012.16 741.56 4801.23 0.00 0.00 0.00 0.00 0.00 16.85
November 3129.59 03-NOV-14:00 2010.79 670.14 2160.55 0.00 0.00 0.00 0.00 0.00 7.64
December 2622.04 13-DEC-06:02 1012.16 741.56 4801.23 0.00 0.00 0.00 0.00 0.00 27.09
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 2038.35   0.00 370.83 2160.55 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 11212.61   2010.79 921.05 4801.23 0.00 0.00 0.00 0.00 26.14 37.22



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_MID_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 1605.71 31-JAN-16:50 1239.33 577.97 1392.34 0.00 0.00 0.00 0.00 0.00 10.54
February 4493.65 27-FEB-10:00 1239.33 409.30 1392.34 0.00 0.00 0.00 0.00 0.00 32.65
March 5431.13 14-MAR-10:10 1239.33 409.30 1392.34 0.00 0.00 0.00 0.00 0.00 18.13
April 11616.28 16-APR-09:23 195.68 68.22 1392.34 0.00 0.00 0.00 0.00 0.00 44.54
May 15376.59 07-MAY-08:53 260.91 90.96 1856.46 0.00 0.00 0.00 0.00 0.00 43.71
June 15356.71 25-JUN-09:23 260.91 90.96 1856.46 0.00 0.00 0.00 0.00 6.89 0.00
July 15352.80 02-JUL-10:13 260.91 90.96 1856.46 0.00 0.00 0.00 0.00 0.00 4.58
August 15486.08 27-AUG-08:32 260.91 90.96 1856.46 0.00 0.00 0.00 0.00 0.00 5.79
September 11462.83 24-SEP-09:23 195.68 68.22 1392.34 0.00 0.00 0.00 0.00 0.00 17.07
October 6385.82 11-OCT-10:10 1239.33 409.30 1392.34 0.00 0.00 0.00 0.00 0.00 3.36
November 3914.93 06-NOV-09:40 1239.33 409.30 1392.34 0.00 0.00 0.00 0.00 0.00 37.59
December 2070.41 13-DEC-06:02 652.28 477.89 3094.09 0.00 0.00 0.00 0.00 0.00 18.08
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 1605.71   195.68 68.22 1392.34 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 15486.08   1239.33 577.97 3094.09 0.00 0.00 0.00 0.00 6.89 44.54



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_MID_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 9232.68 29-JAN-14:03 303.66 105.87 2160.58 0.00 0.00 0.00 0.00 0.00 286.34
February 15730.06 26-FEB-12:43 303.66 105.87 2160.58 0.00 0.00 0.00 0.00 0.00 90.35
March 12364.68 30-MAR-13:40 2010.83 635.14 2160.58 0.00 0.00 0.00 0.00 18.88 0.00
April 11340.11 17-APR-14:50 3846.30 1270.27 4321.17 0.00 0.00 0.00 0.00 13.43 0.00
May 11384.05 19-MAY-05:02 1012.19 741.58 4801.30 0.00 0.00 0.00 0.00 0.00 0.00
June 12600.40 26-JUN-05:02 1012.19 741.58 4801.30 0.00 0.00 0.00 0.00 0.00 4.33
July 12316.09 17-JUL-05:02 1012.19 741.58 4801.30 0.00 0.00 0.00 0.00 0.00 0.73
August 15719.92 13-AUG-16:51 809.75 282.31 5761.56 0.00 0.00 0.00 0.00 56.68 0.00
September 15837.03 24-SEP-12:03 303.66 105.87 2160.58 0.00 0.00 0.00 0.00 20.10 0.00
October 16950.48 09-OCT-14:22 506.09 176.44 3600.97 0.00 0.00 0.00 0.00 0.00 8.47
November 16627.35 11-NOV-13:43 404.87 141.16 2880.78 0.00 0.00 0.00 0.00 0.00 143.00
December 15538.89 10-DEC-14:53 303.66 105.87 2160.58 0.00 0.00 0.00 0.00 0.00 93.19
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 9232.68   303.66 105.87 2160.58 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 16950.48   3846.30 1270.27 5761.56 0.00 0.00 0.00 0.00 56.68 286.34



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_MID_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 2015.37 20-JAN-16:30 1239.33 409.30 1392.33 0.00 0.00 0.00 0.00 0.00 26.50
February 6263.30 27-FEB-17:00 1239.33 409.30 1392.33 0.00 0.00 0.00 0.00 0.00 2.72
March 9886.81 30-MAR-05:02 652.28 477.89 3094.07 0.00 0.00 0.00 0.00 0.00 18.01
April 14543.65 09-APR-16:52 326.14 113.70 2320.55 0.00 0.00 0.00 0.00 0.00 21.48
May 16555.12 21-MAY-17:02 0.00 113.70 1801.74 0.00 0.00 0.00 0.00 0.00 20.93
June 16103.07 25-JUN-16:42 326.14 113.70 2320.55 0.00 0.00 0.00 0.00 86.19 0.00
July 16685.26 02-JUL-18:12 0.00 136.45 2162.09 0.00 0.00 0.00 0.00 18.20 0.00
August 17944.76 13-AUG-16:51 521.82 181.93 3712.89 0.00 0.00 0.00 0.00 19.86 0.00
September 16100.02 04-SEP-16:33 260.91 90.96 1856.44 0.00 0.00 0.00 0.00 6.78 0.00
October 14639.62 09-OCT-16:23 260.91 90.96 1856.44 0.00 0.00 0.00 0.00 3.47 0.00
November 5962.62 06-NOV-16:00 1239.33 409.30 1392.33 0.00 0.00 0.00 0.00 0.00 19.48
December 3185.76 11-DEC-15:40 1239.33 409.30 1392.33 0.00 0.00 0.00 0.00 0.00 8.45
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 2015.37   0.00 90.96 1392.33 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 17944.76   1239.33 477.89 3712.89 0.00 0.00 0.00 0.00 86.19 26.50



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_TOP_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 2035.64 20-JAN-16:40 1923.11 725.06 2160.55 0.00 0.00 0.00 0.00 0.00 41.19
February 2989.47 28-FEB-15:40 1923.11 635.12 2160.55 0.00 0.00 0.00 0.00 0.00 3.68
March 6245.04 30-MAR-15:50 1923.11 635.12 2160.55 0.00 0.00 0.00 0.00 31.49 0.00
April 6536.07 19-APR-14:30 1923.11 635.12 2160.55 0.00 0.00 0.00 0.00 14.37 0.00
May 11259.01 19-MAY-05:02 1012.16 741.56 4801.23 0.00 0.00 0.00 0.00 0.00 0.00
June 13026.47 18-JUN-16:03 404.87 141.15 2880.74 0.00 0.00 0.00 0.00 87.97 0.00
July 15153.30 02-JUL-18:12 0.00 211.73 3355.02 0.00 0.00 0.00 0.00 44.14 0.00
August 15371.86 13-AUG-16:51 809.73 282.30 5761.47 0.00 0.00 0.00 0.00 68.38 0.00
September 11363.00 27-SEP-05:03 809.73 593.25 3840.98 0.00 0.00 0.00 0.00 0.00 6.76
October 9466.67 19-OCT-05:02 1012.16 741.56 4801.23 0.00 0.00 0.00 0.00 0.00 21.11
November 2712.77 03-NOV-15:40 1923.11 719.70 2160.55 0.00 0.00 0.00 0.00 0.00 21.02
December 2264.48 13-DEC-15:10 1923.11 735.42 2160.55 0.00 0.00 0.00 0.00 0.00 22.48
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 2035.64   0.00 141.15 2160.55 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 15371.86   1923.11 741.56 5761.47 0.00 0.00 0.00 0.00 87.97 41.19



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_TOP_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 1561.33 20-JAN-16:40 1239.33 532.16 1392.34 0.00 0.00 0.00 0.00 0.00 26.48
February 3023.00 28-FEB-15:00 1295.83 409.30 1392.34 0.00 0.00 0.00 0.00 7.04 0.00
March 5122.67 30-MAR-11:00 1239.33 409.30 1392.34 0.00 0.00 0.00 0.00 0.00 9.67
April 9768.45 16-APR-11:13 195.68 68.22 1392.34 0.00 0.00 0.00 0.00 0.00 5.86
May 15766.00 07-MAY-09:43 260.91 90.96 1856.46 0.00 0.00 0.00 0.00 0.00 43.96
June 15812.50 25-JUN-09:23 260.91 90.96 1856.46 0.00 0.00 0.00 0.00 6.94 0.00
July 15829.49 02-JUL-10:13 260.91 90.96 1856.46 0.00 0.00 0.00 0.00 0.00 7.03
August 15849.48 27-AUG-08:32 260.91 90.96 1856.46 0.00 0.00 0.00 0.00 0.00 7.36
September 10801.39 07-SEP-05:02 652.28 477.89 3094.09 0.00 0.00 0.00 0.00 0.00 4.85
October 6150.07 11-OCT-10:20 1239.33 409.30 1392.34 0.00 0.00 0.00 0.00 0.00 2.29
November 2460.62 06-NOV-10:50 1295.83 409.30 1392.34 0.00 0.00 0.00 0.00 0.00 49.83
December 1758.50 13-DEC-15:10 1239.33 471.34 1392.34 0.00 0.00 0.00 0.00 0.00 14.60
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 1561.33   195.68 68.22 1392.34 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 15849.48   1295.83 532.16 3094.09 0.00 0.00 0.00 0.00 7.04 49.83



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_TOP_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 6630.73 11-JAN-14:40 2010.83 635.14 2160.58 0.00 0.00 0.00 0.00 0.00 49.39
February 15913.68 26-FEB-14:53 303.66 105.87 2160.58 0.00 0.00 0.00 0.00 0.00 41.04
March 13022.00 30-MAR-13:50 2010.83 635.14 2160.58 0.00 0.00 0.00 0.00 23.95 0.00
April 14488.82 16-APR-13:53 303.66 105.87 2160.58 0.00 0.00 0.00 0.00 24.32 0.00
May 15323.54 29-MAY-15:32 404.87 141.16 2880.78 0.00 0.00 0.00 0.00 19.41 0.00
June 14858.16 18-JUN-16:03 404.87 141.16 2880.78 0.00 0.00 0.00 0.00 88.34 0.00
July 17154.00 02-JUL-18:12 0.00 227.57 3355.08 0.00 0.00 0.00 0.00 46.12 0.00
August 18050.51 13-AUG-16:51 809.75 282.31 5761.56 0.00 0.00 0.00 0.00 61.48 0.00
September 18471.12 24-SEP-14:23 404.87 141.16 2880.78 0.00 0.00 0.00 0.00 17.50 0.00
October 18602.10 09-OCT-13:53 404.87 141.16 2880.78 0.00 0.00 0.00 0.00 0.00 10.28
November 16275.35 11-NOV-14:12 506.09 176.44 3600.97 0.00 0.00 0.00 0.00 0.00 149.07
December 9222.88 08-DEC-14:30 2010.83 635.14 2160.58 0.00 0.00 0.00 0.00 0.00 127.52
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 6630.73   0.00 105.87 2160.58 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 18602.10   2010.83 635.14 5761.56 0.00 0.00 0.00 0.00 88.34 149.07



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_TOP_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 2024.58 20-JAN-16:40 1239.33 409.30 1392.33 0.00 0.00 0.00 0.00 0.00 31.35
February 5915.94 27-FEB-17:00 1239.33 409.30 1392.33 0.00 0.00 0.00 0.00 0.00 3.57
March 10541.48 31-MAR-05:02 652.28 477.89 3094.07 0.00 0.00 0.00 0.00 0.00 39.78
April 12981.69 15-APR-17:05 391.37 136.45 2784.67 0.00 0.00 0.00 0.00 0.00 5.66
May 17199.16 29-MAY-15:32 260.91 90.96 1856.44 0.00 0.00 0.00 0.00 12.08 0.00
June 18642.81 11-JUN-16:32 391.37 136.45 2784.67 0.00 0.00 0.00 0.00 60.30 0.00
July 18168.59 02-JUL-18:12 0.00 136.45 2162.09 0.00 0.00 0.00 0.00 18.15 0.00
August 19812.96 13-AUG-16:51 521.82 181.93 3712.89 0.00 0.00 0.00 0.00 19.82 0.00
September 17402.89 04-SEP-16:42 260.91 90.96 1856.44 0.00 0.00 0.00 0.00 8.31 0.00
October 9821.20 09-OCT-17:13 0.00 68.22 1081.05 0.00 0.00 0.00 0.00 0.00 9.91
November 5518.71 06-NOV-16:00 1239.33 409.30 1392.33 0.00 0.00 0.00 0.00 0.00 24.94
December 2327.25 12-DEC-14:40 1295.83 409.30 1392.33 0.00 0.00 0.00 0.00 0.00 6.22
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 2024.58   0.00 68.22 1081.05 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 19812.96   1295.83 477.89 3712.89 0.00 0.00 0.00 0.00 60.30 39.78



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: GROUNDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 3692.82 02-JAN-06:08 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 62.09
February 5107.41 28-FEB-06:15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 52.98
March 5269.85 13-MAR-05:15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 24.70
April 7251.29 17-APR-14:00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5.29 0.00
May 7845.13 30-MAY-05:25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 10.33
June 9395.53 19-JUN-05:15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 10.28
July 13050.14 17-JUL-05:15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.61
August 12436.74 07-AUG-05:15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5.46
September 10807.73 11-SEP-05:15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 3.09
October 9941.55 10-OCT-05:15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 24.68
November 7116.26 06-NOV-06:15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 58.06
December 4119.48 13-DEC-06:15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 28.94
                       
Annual Sum or Average     0.00 0.00 0.00 0.00 0.00 0.00 0.00    
Minimum of Months 3692.82   0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 13050.14   0.00 0.00 0.00 0.00 0.00 0.00 0.00 5.29 62.09



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: MIDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 3716.30 09-JAN-04:01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 756.95
February 4277.65 03-FEB-05:01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 987.21
March 3690.30 15-MAR-05:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 162.70
April 5485.66 17-APR-15:30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 16.61 0.00
May 6768.45 30-MAY-05:02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 17.45
June 7457.02 15-JUN-05:02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 24.31
July 6820.57 01-JUL-05:15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 24.40
August 7770.16 11-AUG-05:03 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 15.58
September 6937.05 11-SEP-05:02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2.72
October 4391.37 11-OCT-05:15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 41.48
November 4624.88 21-NOV-06:01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 205.67
December 4352.96 01-DEC-06:01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 167.58
                       
Annual Sum or Average     0.00 0.00 0.00 0.00 0.00 0.00 0.00    
Minimum of Months 3690.30   0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 7770.16   0.00 0.00 0.00 0.00 0.00 0.00 0.00 16.61 987.21



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: TOPFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 1382.41 31-JAN-13:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 40.79
February 5659.70 28-FEB-16:00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 25.58
March 12720.67 30-MAR-15:30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 26.76 0.00
April 17321.53 17-APR-15:00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 17.10 0.00
May 17626.10 19-MAY-13:35 0.00 0.00 0.00 0.00 0.00 0.00 0.00 42.33 0.00
June 17453.75 13-JUN-13:50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 22.43 0.00
July 19506.40 07-JUL-15:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 28.57 0.00
August 18229.44 01-AUG-14:20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 47.54 0.00
September 14891.74 06-SEP-14:50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 26.69 0.00
October 10450.82 10-OCT-15:20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20.58 0.00
November 4404.87 05-NOV-14:30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 15.95
December 2119.04 12-DEC-13:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 32.60
                       
Annual Sum or Average     0.00 0.00 0.00 0.00 0.00 0.00 0.00    
Minimum of Months 1382.41   0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 19506.40   0.00 0.00 0.00 0.00 0.00 0.00 0.00 47.54 40.79



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: DATACENTER_BOT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 1739.54 23-JAN-17:00 222.14 284.97 1948.61 0.00 0.00 0.00 0.00 0.00 0.00
February 3909.31 20-FEB-17:50 23.38 31.66 7794.42 0.00 0.00 0.00 0.00 0.00 0.00
March 7149.51 31-MAR-24:00 0.00 15.83 7794.42 0.00 0.00 0.00 0.00 0.00 0.00
April 7854.47 09-APR-18:23 0.00 47.50 23383.27 0.00 0.00 0.00 0.00 0.00 0.00
May 3458.30 31-MAY-24:00 0.00 15.83 3897.21 0.00 0.00 0.00 0.00 0.00 0.00
June 5329.73 30-JUN-24:00 0.00 15.83 5845.82 0.00 0.00 0.00 0.00 0.00 0.00
July 7233.00 31-JUL-23:57 0.00 47.50 23383.27 0.00 0.00 0.00 0.00 0.00 0.00
August 7858.10 13-AUG-18:40 0.00 31.66 15588.84 0.00 0.00 0.00 0.00 0.00 0.00
September 3244.74 30-SEP-24:00 0.00 15.83 3897.21 0.00 0.00 0.00 0.00 0.00 0.00
October 5155.81 31-OCT-24:00 0.00 15.83 5845.82 0.00 0.00 0.00 0.00 0.00 0.00
November 5820.53 11-NOV-16:55 23.38 31.66 11691.63 0.00 0.00 0.00 0.00 0.00 0.00
December 7561.67 10-DEC-17:00 23.38 31.66 15588.84 0.00 0.00 0.00 0.00 0.00 0.00
                       
Annual Sum or Average           0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 1739.54   0.00 15.83 1948.61 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 7858.10   222.14 284.97 23383.27 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: DATACENTER_MID_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 1395.33 26-JAN-17:00 222.14 284.97 1948.61 0.00 0.00 0.00 0.00 0.00 0.00
February 3514.92 24-FEB-17:50 70.15 158.31 3897.21 0.00 0.00 0.00 0.00 0.00 0.00
March 6720.55 31-MAR-24:00 0.00 15.83 7794.42 0.00 0.00 0.00 0.00 0.00 0.00
April 7303.13 09-APR-18:27 0.00 47.50 23383.27 0.00 0.00 0.00 0.00 0.00 0.00
May 3266.89 31-MAY-24:00 0.00 15.83 3897.21 0.00 0.00 0.00 0.00 0.00 0.00
June 5108.79 30-JUN-24:00 0.00 15.83 5845.82 0.00 0.00 0.00 0.00 0.00 0.00
July 6984.12 31-JUL-23:57 0.00 47.50 23383.27 0.00 0.00 0.00 0.00 0.00 0.00
August 7398.44 13-AUG-18:40 0.00 31.66 15588.84 0.00 0.00 0.00 0.00 0.00 0.00
September 2774.88 30-SEP-24:00 0.00 15.83 3897.21 0.00 0.00 0.00 0.00 0.00 0.00
October 4482.49 31-OCT-24:00 0.00 15.83 5845.82 0.00 0.00 0.00 0.00 0.00 0.00
November 5391.13 06-NOV-17:00 222.14 284.97 5845.82 0.00 0.00 0.00 0.00 0.00 0.00
December 6994.97 08-DEC-17:00 222.14 284.97 7794.42 0.00 0.00 0.00 0.00 0.00 0.00
                       
Annual Sum or Average           0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 1395.33   0.00 15.83 1948.61 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 7398.44   222.14 284.97 23383.27 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: DATACENTER_TOP_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 1324.89 20-JAN-17:00 222.14 284.97 1948.61 0.00 0.00 0.00 0.00 0.00 0.00
February 3501.14 28-FEB-17:00 222.14 284.97 3897.21 0.00 0.00 0.00 0.00 0.00 0.00
March 6485.82 31-MAR-23:30 0.00 15.83 7794.42 0.00 0.00 0.00 0.00 0.00 0.00
April 7355.06 09-APR-18:16 0.00 79.16 38972.11 0.00 0.00 0.00 0.00 0.00 0.00
May 3233.58 31-MAY-24:00 0.00 15.83 3897.21 0.00 0.00 0.00 0.00 0.00 0.00
June 5093.05 30-JUN-24:00 0.00 15.83 5845.82 0.00 0.00 0.00 0.00 0.00 0.00
July 7025.16 31-JUL-23:57 0.00 47.50 23383.27 0.00 0.00 0.00 0.00 0.00 0.00
August 7648.82 13-AUG-19:10 0.00 79.16 38972.11 0.00 0.00 0.00 0.00 0.00 0.00
September 2306.31 30-SEP-24:00 0.00 15.83 3897.21 0.00 0.00 0.00 0.00 0.00 0.00
October 3953.36 31-OCT-23:30 0.00 15.83 5845.82 0.00 0.00 0.00 0.00 0.00 0.00
November 5369.06 06-NOV-17:00 222.14 284.97 5845.82 0.00 0.00 0.00 0.00 0.00 0.00
December 6841.67 13-DEC-16:30 222.14 284.97 7794.42 0.00 0.00 0.00 0.00 0.00 0.00
                       
Annual Sum or Average           0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 1324.89   0.00 15.83 1948.61 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 7648.82   222.14 284.97 38972.11 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: DATACENTER_BASEMENT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 90170.26 02-JAN-17:00 4808.68 3337.76 94908.13 0.00 0.00 0.00 0.00 0.00 0.00
February 181752.05 21-FEB-17:00 4808.68 3337.76 189816.26 0.00 0.00 0.00 0.00 0.00 0.00
March 357204.03 31-MAR-24:00 0.00 185.45 379632.52 0.00 0.00 0.00 0.00 0.00 0.00
April 364243.34 17-APR-15:55 9617.36 6675.52 759265.04 0.00 0.00 0.00 0.00 0.00 0.00
May 174536.61 31-MAY-24:00 0.00 185.45 189816.26 0.00 0.00 0.00 0.00 0.00 0.00
June 266538.74 30-JUN-24:00 0.00 185.45 284724.39 0.00 0.00 0.00 0.00 0.00 0.00
July 358893.96 31-JUL-23:53 0.00 556.35 1138897.57 0.00 0.00 0.00 0.00 0.00 0.00
August 366909.35 07-AUG-16:00 4808.68 3337.76 379632.52 0.00 0.00 0.00 0.00 0.00 0.00
September 175371.16 30-SEP-24:00 0.00 185.45 189816.26 0.00 0.00 0.00 0.00 0.00 0.00
October 267538.44 31-OCT-24:00 0.00 185.45 284724.39 0.00 0.00 0.00 0.00 0.00 0.00
November 275646.64 06-NOV-17:00 4808.68 3337.76 284724.39 0.00 0.00 0.00 0.00 0.00 0.00
December 366485.48 11-DEC-17:00 4808.68 3337.76 379632.52 0.00 0.00 0.00 0.00 0.00 0.00
                       
Annual Sum or Average           0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 90170.26   0.00 185.45 94908.13 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 366909.35   9617.36 6675.52 1138897.57 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: EnergyConsumptionElectricityNaturalGasMonthly

For: Meter

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum} [W] ELECTRICITY:FACILITY {TIMESTAMP} NATURALGAS:FACILITY [J] NATURALGAS:FACILITY {Maximum} [W] NATURALGAS:FACILITY {TIMESTAMP}
January 0.127067E+13 849908.76 31-JAN-16:00 0.238892E+12 1108500.87 09-JAN-07:10
February 0.151374E+13 1079053.61 28-FEB-16:30 0.143143E+12 1029005.12 13-FEB-07:10
March 0.214227E+13 1389371.50 30-MAR-15:30 0.692481E+11 266539.86 18-MAR-06:10
April 0.247870E+13 1652636.69 12-APR-15:20 0.584236E+11 306980.48 06-APR-06:10
May 0.154895E+13 1300009.00 15-MAY-15:00 0.578322E+11 193583.74 15-MAY-14:39
June 0.203285E+13 1369789.69 02-JUN-15:09 0.523012E+11 139647.44 02-JUN-14:20
July 0.249190E+13 1503967.45 07-JUL-15:09 0.483358E+11 66997.16 03-JUL-11:30
August 0.296676E+13 1637780.83 10-AUG-15:00 0.513547E+11 112954.88 25-AUG-11:30
September 0.153335E+13 1190596.60 05-SEP-15:39 0.494148E+11 121127.92 14-SEP-15:50
October 0.178793E+13 1259955.62 10-OCT-15:50 0.569681E+11 318600.37 26-OCT-06:10
November 0.202807E+13 1194715.46 08-NOV-16:30 0.754208E+11 596977.23 22-NOV-07:10
December 0.240063E+13 1312133.44 12-DEC-16:00 0.131473E+12 745959.71 18-DEC-07:10
             
Annual Sum or Average 0.241958E+14     0.103281E+13    
Minimum of Months 0.127067E+13 849908.76   0.483358E+11 66997.16  
Maximum of Months 0.296676E+13 1652636.69   0.238892E+12 1108500.87  



Table of Contents

Report: EnergyConsumptionDistrictHeatingCoolingMonthly

For: Meter

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

DISTRICTCOOLING:FACILITY [J] DISTRICTCOOLING:FACILITY {Maximum} [W] DISTRICTCOOLING:FACILITY {TIMESTAMP} DISTRICTHEATING:FACILITY [J] DISTRICTHEATING:FACILITY {Maximum} [W] DISTRICTHEATING:FACILITY {TIMESTAMP}
January 0.236388E+12 92846.09 02-JAN-14:00 136471.51 8.58 16-JAN-18:40
February 0.433715E+12 184351.09 21-FEB-16:00 162087.27 13.45 01-FEB-00:40
March 0.726938E+12 357204.92 31-MAR-23:00 182411.67 11.12 31-MAR-23:30
April 0.938759E+12 366842.26 17-APR-15:00 103258.02 10.65 24-APR-23:30
May 0.239428E+12 174540.12 31-MAY-23:00 119227.74 13.36 31-MAY-23:40
June 0.469346E+12 266540.47 30-JUN-23:00 47169.49 15.01 30-JUN-23:30
July 0.731159E+12 358894.15 31-JUL-23:00 68931.84 9.37 31-JUL-23:19
August 0.977639E+12 369582.79 07-AUG-13:00 86780.73 7.17 25-AUG-23:19
September 0.236761E+12 175371.16 30-SEP-23:00 108610.28 5.37 25-SEP-23:40
October 0.488178E+12 267540.18 31-OCT-23:00 165925.90 11.07 31-OCT-23:30
November 0.709276E+12 278255.62 06-NOV-14:00 182551.21 7.65 17-NOV-00:30
December 0.975851E+12 369132.77 12-DEC-14:00 203590.02 11.13 01-DEC-00:30
             
Annual Sum or Average 0.716344E+13     1567015.67    
Minimum of Months 0.236388E+12 92846.09   47169.49 5.37  
Maximum of Months 0.977639E+12 369582.79   203590.02 15.01  



Table of Contents

Report: EndUseEnergyConsumptionElectricityMonthly

For: Meter

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

INTERIORLIGHTS:ELECTRICITY [J] EXTERIORLIGHTS:ELECTRICITY [J] INTERIOREQUIPMENT:ELECTRICITY [J] EXTERIOREQUIPMENT:ELECTRICITY [J] FANS:ELECTRICITY [J] PUMPS:ELECTRICITY [J] HEATING:ELECTRICITY [J] COOLING:ELECTRICITY [J] HEATREJECTION:ELECTRICITY [J] HUMIDIFIER:ELECTRICITY [] HEATRECOVERY:ELECTRICITY [J] WATERSYSTEMS:ELECTRICITY [] COGENERATION:ELECTRICITY []
January 0.171855E+12 0.351723E+11 0.766053E+12 0.207862E+12 0.620197E+11 0.119566E+11 0.00 0.856692E+10 0.186220E+10 0.00 0.531877E+10 0.00 0.00
February 0.155932E+12 0.288582E+11 0.978954E+12 0.229082E+12 0.598214E+11 0.182124E+11 0.00 0.322555E+11 0.745600E+10 0.00 0.316656E+10 0.00 0.00
March 0.182105E+12 0.283728E+11 0.141687E+13 0.299605E+12 0.821771E+11 0.368350E+11 0.00 0.754683E+11 0.197489E+11 0.00 0.109032E+10 0.00 0.00
April 0.161759E+12 0.240267E+11 0.165903E+13 0.333797E+12 0.923156E+11 0.561264E+11 0.00 0.120934E+12 0.295807E+11 0.00 0.113467E+10 0.00 0.00
May 0.173645E+12 0.217141E+11 0.774844E+12 0.208007E+12 0.112028E+12 0.679812E+11 0.00 0.141834E+12 0.458384E+11 0.00 0.305635E+10 0.00 0.00
June 0.172431E+12 0.198022E+11 0.106252E+13 0.245640E+12 0.135161E+12 0.877857E+11 0.00 0.231722E+12 0.715591E+11 0.00 0.622722E+10 0.00 0.00
July 0.161812E+12 0.210531E+11 0.139340E+13 0.299361E+12 0.138433E+12 0.102533E+12 0.00 0.278259E+12 0.900881E+11 0.00 0.695397E+10 0.00 0.00
August 0.180610E+12 0.235546E+11 0.173200E+13 0.345115E+12 0.149785E+12 0.110251E+12 0.00 0.318910E+12 0.988150E+11 0.00 0.772134E+10 0.00 0.00
September 0.162556E+12 0.258751E+11 0.740713E+12 0.201201E+12 0.107999E+12 0.710802E+11 0.00 0.162463E+12 0.571660E+11 0.00 0.429309E+10 0.00 0.00
October 0.170835E+12 0.302716E+11 0.108340E+13 0.253680E+12 0.848499E+11 0.436311E+11 0.00 0.917436E+11 0.275425E+11 0.00 0.197295E+10 0.00 0.00
November 0.169232E+12 0.330601E+11 0.135889E+13 0.289765E+12 0.701707E+11 0.282431E+11 0.00 0.615455E+11 0.156248E+11 0.00 0.153398E+10 0.00 0.00
December 0.166549E+12 0.362104E+11 0.170972E+13 0.345057E+12 0.651515E+11 0.131685E+11 0.00 0.512540E+11 0.106222E+11 0.00 0.289375E+10 0.00 0.00
                           
Annual Sum or Average 0.202932E+13 0.327971E+12 0.146764E+14 0.325817E+13 0.115991E+13 0.647804E+12 0.00 0.157496E+13 0.475904E+12 0.00 0.453630E+11 0.00 0.00
Minimum of Months 0.155932E+12 0.198022E+11 0.740713E+12 0.201201E+12 0.598214E+11 0.119566E+11 0.00 0.856692E+10 0.186220E+10 0.00 0.109032E+10 0.00 0.00
Maximum of Months 0.182105E+12 0.362104E+11 0.173200E+13 0.345115E+12 0.149785E+12 0.110251E+12 0.00 0.318910E+12 0.988150E+11 0.00 0.772134E+10 0.00 0.00



Table of Contents

Report: EndUseEnergyConsumptionNaturalGasMonthly

For: Meter

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

INTERIOREQUIPMENT:NATURALGAS [] EXTERIOREQUIPMENT:NATURALGAS [] HEATING:NATURALGAS [J] COOLING:NATURALGAS [] WATERSYSTEMS:NATURALGAS [J] COGENERATION:NATURALGAS [] HUMIDIFIER:NATURALGAS []
January 0.00 0.00 0.177552E+12 0.00 0.613398E+11 0.00 0.00
February 0.00 0.00 0.874052E+11 0.00 0.557378E+11 0.00 0.00
March 0.00 0.00 0.633634E+10 0.00 0.629117E+11 0.00 0.00
April 0.00 0.00 0.306058E+10 0.00 0.553631E+11 0.00 0.00
May 0.00 0.00 0.263672E+10 0.00 0.551955E+11 0.00 0.00
June 0.00 0.00 0.103781E+10 0.00 0.512634E+11 0.00 0.00
July 0.00 0.00 2675.90 0.00 0.483358E+11 0.00 0.00
August 0.00 0.00 0.124096E+09 0.00 0.512306E+11 0.00 0.00
September 0.00 0.00 0.401542E+09 0.00 0.490132E+11 0.00 0.00
October 0.00 0.00 0.357409E+10 0.00 0.533940E+11 0.00 0.00
November 0.00 0.00 0.200430E+11 0.00 0.553778E+11 0.00 0.00
December 0.00 0.00 0.729329E+11 0.00 0.585399E+11 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.375104E+12 0.00 0.657703E+12 0.00 0.00
Minimum of Months 0.00 0.00 2675.90 0.00 0.483358E+11 0.00 0.00
Maximum of Months 0.00 0.00 0.177552E+12 0.00 0.629117E+11 0.00 0.00



Table of Contents

Report: PeakEnergyEndUseElectricityPart1Monthly

For: Meter

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

INTERIORLIGHTS:ELECTRICITY {Maximum} [W] INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} EXTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] EXTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} FANS:ELECTRICITY {Maximum} [W] FANS:ELECTRICITY {TIMESTAMP} PUMPS:ELECTRICITY {Maximum} [W] PUMPS:ELECTRICITY {TIMESTAMP} HEATING:ELECTRICITY {Maximum} [W] HEATING:ELECTRICITY {TIMESTAMP}
January 194718.61 03-JAN-08:09 37611.08 01-JAN-06:10 423497.50 02-JAN-08:09 133946.64 03-JAN-08:20 47378.51 09-JAN-06:10 40536.72 09-JAN-06:19 0.00 01-JAN-00:10
February 197610.22 01-FEB-08:09 37611.08 01-FEB-06:10 541788.89 01-FEB-08:09 151031.63 01-FEB-08:20 91280.07 28-FEB-16:10 57747.73 28-FEB-14:00 0.00 01-FEB-00:10
March 195296.00 21-MAR-07:10 37611.08 01-MAR-06:10 660080.29 01-MAR-08:09 168113.88 21-MAR-07:19 121840.15 29-MAR-15:39 61144.74 30-MAR-14:00 0.00 01-MAR-00:10
April 191399.93 03-APR-07:10 37611.08 01-APR-05:10 778371.69 03-APR-07:10 185195.29 03-APR-07:19 202658.14 12-APR-15:20 62442.80 17-APR-14:39 0.00 01-APR-00:10
May 180478.78 24-MAY-07:10 37611.08 01-MAY-05:10 423497.50 01-MAY-07:10 133939.14 24-MAY-07:19 232032.16 15-MAY-15:00 62594.34 15-MAY-15:00 0.00 01-MAY-00:10
June 177494.54 23-JUN-07:10 37611.08 01-JUN-05:10 541788.89 01-JUN-07:10 151021.03 23-JUN-07:19 220520.16 02-JUN-14:00 60091.53 02-JUN-13:00 0.00 01-JUN-00:10
July 183966.14 27-JUL-07:10 37611.08 01-JUL-05:10 660080.29 03-JUL-07:10 168107.91 27-JUL-07:19 171370.89 07-JUL-15:09 59824.80 07-JUL-09:09 0.00 01-JUL-00:10
August 189705.33 24-AUG-07:10 37611.08 01-AUG-05:10 778371.69 01-AUG-07:10 185194.40 24-AUG-07:19 167600.10 16-AUG-15:50 60265.78 25-AUG-13:00 0.00 01-AUG-00:10
September 192886.36 29-SEP-07:10 37611.08 01-SEP-05:10 423497.50 01-SEP-07:10 133945.67 29-SEP-07:19 183095.78 14-SEP-15:20 61133.51 14-SEP-15:39 0.00 01-SEP-00:10
October 198743.45 30-OCT-07:10 37611.08 01-OCT-05:10 541788.89 02-OCT-07:10 151032.23 30-OCT-07:19 112174.14 02-OCT-15:00 61047.84 10-OCT-15:09 0.00 01-OCT-00:10
November 198074.02 01-NOV-07:10 37611.08 01-NOV-05:10 660080.29 01-NOV-07:10 168115.34 01-NOV-07:19 90360.37 06-NOV-16:40 38520.17 06-NOV-12:50 0.00 01-NOV-00:10
December 194801.94 06-DEC-08:09 37611.08 01-DEC-06:10 778371.69 01-DEC-08:09 185197.08 06-DEC-08:20 62707.14 12-DEC-14:30 39265.44 04-DEC-06:10 0.00 01-DEC-00:10
                             
Annual Sum or Average                            
Minimum of Months 177494.54   37611.08   423497.50   133939.14   47378.51   38520.17   0.00  
Maximum of Months 198743.45   37611.08   778371.69   185197.08   232032.16   62594.34   0.00  



Table of Contents

Report: PeakEnergyEndUseElectricityPart2Monthly

For: Meter

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

COOLING:ELECTRICITY {Maximum} [W] COOLING:ELECTRICITY {TIMESTAMP} HEATREJECTION:ELECTRICITY {Maximum} [W] HEATREJECTION:ELECTRICITY {TIMESTAMP} HUMIDIFIER:ELECTRICITY [] HEATRECOVERY:ELECTRICITY {Maximum} [W] HEATRECOVERY:ELECTRICITY {TIMESTAMP} WATERSYSTEMS:ELECTRICITY [] COGENERATION:ELECTRICITY []
January 68204.88 31-JAN-15:50 13551.78 19-JAN-21:00 0.00 5613.48 02-JAN-07:10 0.00 0.00
February 112799.07 28-FEB-14:00 14384.65 28-FEB-14:39 0.00 5613.48 01-FEB-07:10 0.00 0.00
March 229927.76 30-MAR-14:00 52437.43 30-MAR-13:09 0.00 5613.48 03-MAR-07:10 0.00 0.00
April 254536.16 12-APR-15:20 52437.43 11-APR-15:30 0.00 5613.48 04-APR-09:09 0.00 0.00
May 258320.77 15-MAY-15:00 52437.43 08-MAY-09:00 0.00 5613.48 02-MAY-15:00 0.00 0.00
June 242837.95 23-JUN-10:20 52437.43 01-JUN-13:20 0.00 5613.48 01-JUN-06:40 0.00 0.00
July 256695.03 07-JUL-15:50 52437.43 01-JUL-06:49 0.00 5613.48 01-JUL-06:10 0.00 0.00
August 261918.69 02-AUG-12:09 52437.43 01-AUG-06:00 0.00 5613.48 01-AUG-06:10 0.00 0.00
September 242404.94 06-SEP-12:09 52437.43 01-SEP-12:20 0.00 5613.48 01-SEP-06:10 0.00 0.00
October 235726.43 11-OCT-12:09 52437.43 02-OCT-10:50 0.00 5613.48 02-OCT-08:39 0.00 0.00
November 104124.52 02-NOV-13:00 16277.12 27-NOV-16:00 0.00 5613.48 07-NOV-07:10 0.00 0.00
December 101326.23 12-DEC-14:30 15279.79 13-DEC-10:00 0.00 5613.48 01-DEC-07:10 0.00 0.00
                   
Annual Sum or Average         0.00     0.00 0.00
Minimum of Months 68204.88   13551.78   0.00 5613.48   0.00 0.00
Maximum of Months 261918.69   52437.43   0.00 5613.48   0.00 0.00



Table of Contents

Report: ElectricComponentsOfPeakDemandMonthly

For: Meter

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ELECTRICITY:FACILITY {Maximum} [W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W]
January 849908.76 31-JAN-16:00 178339.76 423497.50 0.00 99893.65 41252.42 37312.90 0.00 56816.61 12795.92
February 1079053.61 28-FEB-16:30 172014.68 541788.89 0.00 116974.36 90021.63 37543.02 0.00 107034.26 13676.75
March 1389371.50 30-MAR-15:30 171235.93 660080.29 0.00 134057.82 102220.01 60377.24 0.00 227072.23 32456.83
April 1652636.69 12-APR-15:20 171235.93 778371.69 0.00 151141.29 202658.14 62236.66 0.00 254536.16 32456.83
May 1300009.00 15-MAY-15:00 171235.93 423497.50 0.00 99890.88 232032.16 62594.34 0.00 258320.77 52437.43
June 1369789.69 02-JUN-15:09 171235.93 541788.89 0.00 116974.35 206186.67 59849.54 0.00 219445.71 52437.43
July 1503967.45 07-JUL-15:09 171235.93 660080.29 0.00 134057.82 171370.89 59411.85 0.00 249759.77 52437.43
August 1637780.83 10-AUG-15:00 171235.93 778371.69 0.00 151141.29 160406.84 59401.27 0.00 259172.91 52437.43
September 1190596.60 05-SEP-15:39 171235.93 423497.50 0.00 99890.88 150927.06 59451.29 0.00 227543.04 52437.43
October 1259955.62 10-OCT-15:50 171897.83 541788.89 0.00 116974.36 81807.32 60884.33 0.00 228551.98 52437.43
November 1194715.46 08-NOV-16:30 177122.32 660080.29 0.00 134060.57 80129.97 37405.61 0.00 93120.80 12795.92
December 1312133.44 12-DEC-16:00 187728.31 778371.69 0.00 151148.63 54544.10 37422.64 0.00 88649.39 14268.69
                       
Annual Sum or Average                      
Minimum of Months 849908.76   171235.93 423497.50 0.00 99890.88 41252.42 37312.90 0.00 56816.61 12795.92
Maximum of Months 1652636.69   187728.31 778371.69 0.00 151148.63 232032.16 62594.34 0.00 259172.91 52437.43



Table of Contents

Report: PeakEnergyEndUseNaturalGasMonthly

For: Meter

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

INTERIOREQUIPMENT:NATURALGAS [] EXTERIOREQUIPMENT:NATURALGAS [] HEATING:NATURALGAS {Maximum} [W] HEATING:NATURALGAS {TIMESTAMP} COOLING:NATURALGAS [] WATERSYSTEMS:NATURALGAS {Maximum} [W] WATERSYSTEMS:NATURALGAS {TIMESTAMP} COGENERATION:NATURALGAS []
January 0.00 0.00 1079376.27 09-JAN-07:10 0.00 79706.68 30-JAN-12:50 0.00
February 0.00 0.00 999841.21 13-FEB-07:10 0.00 79713.29 02-FEB-12:00 0.00
March 0.00 0.00 260843.99 18-MAR-06:10 0.00 79100.58 01-MAR-12:30 0.00
April 0.00 0.00 278151.95 06-APR-06:10 0.00 76927.28 04-APR-11:50 0.00
May 0.00 0.00 160511.73 15-MAY-14:39 0.00 74147.16 01-MAY-11:20 0.00
June 0.00 0.00 108025.69 02-JUN-14:20 0.00 69894.53 05-JUN-11:30 0.00
July 0.00 0.00 4.46 26-JUL-10:09 0.00 66997.16 03-JUL-11:30 0.00
August 0.00 0.00 73814.36 25-AUG-11:30 0.00 66412.30 25-AUG-11:39 0.00
September 0.00 0.00 86931.35 14-SEP-15:50 0.00 69723.21 29-SEP-11:39 0.00
October 0.00 0.00 293786.61 26-OCT-06:10 0.00 73485.73 30-OCT-11:39 0.00
November 0.00 0.00 568232.11 22-NOV-07:10 0.00 76481.76 27-NOV-12:00 0.00
December 0.00 0.00 716979.11 18-DEC-07:10 0.00 78756.43 28-DEC-12:00 0.00
                 
Annual Sum or Average 0.00 0.00     0.00     0.00
Minimum of Months 0.00 0.00 4.46   0.00 66412.30   0.00
Maximum of Months 0.00 0.00 1079376.27   0.00 79713.29   0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: BASEMENT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 9.00 27.12 3.83 27.22
February 0.00 0.00 0.00 0.00 2.33 25.93 0.00 25.93
March 0.00 0.00 0.00 0.00 3.17 25.82 0.00 25.82
April 0.00 0.00 0.00 0.00 4.33 25.86 0.00 25.86
May 0.00 0.00 0.00 0.00 2.50 25.96 0.00 25.96
June 0.00 0.00 0.00 0.00 3.50 25.78 0.33 25.68
July 0.00 0.00 0.00 0.00 4.00 25.97 0.00 25.97
August 0.00 0.00 0.00 0.00 6.00 26.34 0.00 26.34
September 0.00 0.00 0.00 0.00 12.83 26.73 0.00 26.73
October 0.00 0.00 0.00 0.00 15.50 26.81 0.00 26.81
November 0.00 0.00 0.00 0.00 15.67 26.72 1.83 26.78
December 0.00 0.00 0.00 0.00 10.67 26.67 2.00 26.79
                 
Annual Sum or Average 0.00   0.00   89.50 26.56 8.00 26.62
Minimum of Months 0.00 0.00 0.00 0.00 2.33 25.78 0.00 25.68
Maximum of Months 0.00 0.00 0.00 0.00 15.67 27.12 3.83 27.22



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: CORE_BOTTOM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.33 25.60 0.00 25.60
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.50 25.81 0.00 25.81
                 
Annual Sum or Average 0.00   0.00   0.83 25.72 0.00 25.72
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.50 25.81 0.00 25.81



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: CORE_MID

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: CORE_TOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 3.00 18.92 0.67 19.12 0.00 19.12 0.00 19.12
February 1.33 18.93 0.17 19.07 0.00 19.07 0.00 19.07
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 1.33 19.06 0.00 19.06 0.00 19.06 0.00 19.06
                 
Annual Sum or Average 5.67 18.95 0.83 19.09 0.00 19.09 0.00 19.09
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 3.00 19.06 0.67 19.12 0.00 19.12 0.00 19.12



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_BOT_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 1.67 26.81 1.00 27.00
August 0.00 0.00 0.00 0.00 0.67 25.65 0.00 25.65
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   2.33 26.48 1.00 26.73
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 1.67 26.81 1.00 27.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_BOT_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.17 27.35 0.17 27.35
March 0.00 0.00 0.00 0.00 0.17 27.29 0.17 27.29
April 0.00 0.00 0.00 0.00 1.17 27.44 1.17 27.44
May 0.00 0.00 0.00 0.00 2.67 27.50 2.67 27.50
June 0.00 0.00 0.00 0.00 3.33 27.70 3.33 27.70
July 0.00 0.00 0.00 0.00 6.67 27.55 6.67 27.55
August 0.00 0.00 0.00 0.00 5.17 27.47 5.00 27.50
September 0.00 0.00 0.00 0.00 2.00 27.53 2.00 27.53
October 0.00 0.00 0.00 0.00 0.50 27.43 0.50 27.43
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   21.83 27.54 21.67 27.54
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 6.67 27.70 6.67 27.70



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_BOT_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.17 19.40 0.00 19.40 0.17 23.35 0.17 24.67
February 0.00 0.00 0.00 0.00 2.17 27.56 2.17 27.56
March 0.00 0.00 0.00 0.00 0.83 27.34 0.83 27.34
April 0.00 0.00 0.00 0.00 1.00 27.40 1.00 27.40
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 2.83 27.05 2.17 27.19
August 0.00 0.00 0.00 0.00 6.67 27.16 5.33 27.30
September 0.00 0.00 0.00 0.00 2.67 27.45 2.67 27.45
October 0.00 0.00 0.00 0.00 5.33 27.67 5.33 27.67
November 0.00 0.00 0.00 0.00 4.00 27.61 4.00 27.61
December 0.00 0.00 0.00 0.00 1.00 27.46 1.00 27.46
                 
Annual Sum or Average 0.17 19.40 0.00 19.40 26.67 27.36 24.67 27.44
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.17 19.40 0.00 19.40 6.67 27.67 5.33 27.67



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_BOT_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 1.33 27.71 1.17 27.73
March 0.00 0.00 0.00 0.00 6.33 27.47 3.50 27.60
April 0.00 0.00 0.00 0.00 18.00 26.99 5.33 27.18
May 0.00 0.00 0.00 0.00 5.67 27.30 1.83 27.44
June 0.00 0.00 0.00 0.00 22.83 27.01 5.50 27.18
July 0.00 0.00 0.00 0.00 35.67 27.35 10.00 27.49
August 0.00 0.00 0.00 0.00 40.33 27.40 10.00 27.52
September 0.00 0.00 0.00 0.00 9.33 27.03 4.00 27.22
October 0.00 0.00 0.00 0.00 6.17 27.27 3.33 27.47
November 0.00 0.00 0.00 0.00 3.00 27.66 2.67 27.68
December 0.00 0.00 0.00 0.00 1.17 26.88 0.67 27.14
                 
Annual Sum or Average 0.00   0.00   149.83 27.25 48.00 27.41
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 40.33 27.71 10.00 27.73



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_MID_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 5.00 19.05 0.50 19.12 0.00 19.12 0.00 19.12
February 3.00 18.94 0.50 19.09 0.00 19.09 0.00 19.09
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.83 19.18 0.00 19.18 0.00 19.18 0.00 19.18
                 
Annual Sum or Average 8.83 19.03 1.00 19.11 0.00 19.11 0.00 19.11
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5.00 19.18 0.50 19.18 0.00 19.18 0.00 19.18



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_MID_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 3.33 18.98 0.17 19.04 0.00 19.04 0.00 19.04
February 1.33 18.73 0.00 18.73 0.00 18.73 0.00 18.73
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.67 27.63 0.67 27.63
May 0.00 0.00 0.00 0.00 2.67 27.56 2.67 27.56
June 0.00 0.00 0.00 0.00 5.00 27.70 5.00 27.70
July 0.00 0.00 0.00 0.00 9.83 27.64 9.67 27.64
August 0.00 0.00 0.00 0.00 6.50 27.61 6.50 27.61
September 0.00 0.00 0.00 0.00 1.17 27.62 1.17 27.62
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.50 19.24 0.00 19.24 0.00 19.24 0.00 19.24
                 
Annual Sum or Average 5.17 18.94 0.17 18.98 25.83 26.15 25.67 26.82
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 3.33 19.24 0.17 19.24 9.83 27.70 9.67 27.70



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_MID_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 1.67 18.87 0.17 18.97 0.00 18.97 0.00 18.97
February 0.33 18.86 0.00 18.86 2.17 26.40 2.17 26.93
March 0.00 0.00 0.00 0.00 0.50 27.29 0.50 27.29
April 0.00 0.00 0.00 0.00 0.67 27.36 0.67 27.36
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.33 27.36 0.33 27.36
August 0.00 0.00 0.00 0.00 4.00 27.39 4.00 27.39
September 0.00 0.00 0.00 0.00 2.00 27.49 2.00 27.49
October 0.00 0.00 0.00 0.00 6.00 27.32 6.00 27.32
November 0.00 0.00 0.00 0.00 3.17 27.65 3.17 27.65
December 0.00 0.00 0.00 0.00 0.83 27.45 0.83 27.45
                 
Annual Sum or Average 2.00 18.87 0.17 18.95 19.67 26.60 19.67 27.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 1.67 18.87 0.17 18.97 6.00 27.65 6.00 27.65



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_MID_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 2.17 19.05 0.17 19.15 0.00 19.15 0.00 19.15
February 0.83 19.12 0.00 19.12 0.00 19.12 0.00 19.12
March 0.00 0.00 0.00 0.00 0.17 27.33 0.17 27.33
April 0.00 0.00 0.00 0.00 2.83 27.59 1.83 27.59
May 0.00 0.00 0.00 0.00 3.33 27.70 1.67 27.71
June 0.00 0.00 0.00 0.00 6.83 27.61 3.17 27.68
July 0.00 0.00 0.00 0.00 11.67 27.61 4.83 27.70
August 0.00 0.00 0.00 0.00 9.50 27.29 3.67 27.47
September 0.00 0.00 0.00 0.00 3.00 27.59 2.00 27.59
October 0.00 0.00 0.00 0.00 1.17 27.51 0.83 27.55
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 3.00 19.07 0.17 19.14 38.50 26.89 18.17 27.17
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 2.17 19.12 0.17 19.15 11.67 27.70 4.83 27.71



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_TOP_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 36.17 17.71 13.50 17.96 0.00 17.96 0.00 17.96
February 20.83 17.38 8.50 17.59 0.00 17.59 0.00 17.59
March 0.33 19.37 0.00 19.37 0.00 19.37 0.00 19.37
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 1.33 27.34 0.83 27.33
July 0.00 0.00 0.00 0.00 3.33 27.43 2.00 27.43
August 0.00 0.00 0.00 0.00 0.17 27.26 0.17 27.26
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.17 19.41 0.00 19.41 0.00 19.41 0.00 19.41
November 2.00 18.88 0.17 18.99 0.00 18.99 0.00 18.99
December 15.33 18.35 5.17 18.65 0.00 18.65 0.00 18.65
                 
Annual Sum or Average 74.83 17.79 27.33 18.02 4.83 18.45 3.00 18.69
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 36.17 19.41 13.50 19.41 3.33 27.43 2.00 27.43



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_TOP_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 17.17 16.68 2.00 16.63 0.00 16.63 0.00 16.63
February 9.83 16.64 1.67 16.68 0.00 16.68 0.00 16.68
March 0.17 19.38 0.00 19.38 0.00 19.38 0.00 19.38
April 0.00 0.00 0.00 0.00 0.50 27.54 0.50 27.54
May 0.00 0.00 0.00 0.00 3.67 27.53 3.67 27.53
June 0.00 0.00 0.00 0.00 8.67 27.69 7.17 27.71
July 0.00 0.00 0.00 0.00 14.17 27.74 11.33 27.77
August 0.00 0.00 0.00 0.00 9.83 27.65 8.00 27.69
September 0.00 0.00 0.00 0.00 1.50 27.52 1.50 27.52
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 1.17 18.81 0.00 18.81 0.00 18.81 0.00 18.81
December 6.00 18.06 0.17 18.13 0.00 18.13 0.00 18.13
                 
Annual Sum or Average 34.33 17.00 3.83 16.96 38.33 22.33 32.17 23.93
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 17.17 19.38 2.00 19.38 14.17 27.74 11.33 27.77



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_TOP_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 15.50 17.45 2.50 17.61 0.00 17.61 0.00 17.61
February 7.67 17.65 2.00 17.78 0.67 18.41 0.67 18.96
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.83 27.41 0.83 27.41
May 0.00 0.00 0.00 0.00 1.00 27.33 1.00 27.33
June 0.00 0.00 0.00 0.00 2.33 27.41 1.83 27.41
July 0.00 0.00 0.00 0.00 6.83 27.44 5.17 27.44
August 0.00 0.00 0.00 0.00 7.33 27.51 5.33 27.56
September 0.00 0.00 0.00 0.00 2.67 27.54 2.67 27.54
October 0.00 0.00 0.00 0.00 4.17 27.62 4.00 27.63
November 0.83 18.85 0.00 18.85 1.50 24.40 1.50 25.61
December 5.00 18.63 0.50 18.78 0.00 18.78 0.00 18.78
                 
Annual Sum or Average 29.00 17.75 5.00 17.88 27.33 22.16 23.00 23.62
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 15.50 18.85 2.50 18.85 7.33 27.62 5.33 27.63



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_TOP_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 11.83 17.13 1.00 17.03 0.00 17.03 0.00 17.03
February 5.50 17.06 1.00 16.71 0.00 16.71 0.00 16.71
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 2.67 27.67 1.67 27.69
May 0.00 0.00 0.00 0.00 3.50 27.86 1.50 27.88
June 0.00 0.00 0.00 0.00 8.67 27.75 3.67 27.81
July 0.00 0.00 0.00 0.00 14.50 27.74 5.67 27.84
August 0.00 0.00 0.00 0.00 11.67 27.54 4.50 27.68
September 0.00 0.00 0.00 0.00 4.00 27.53 2.67 27.58
October 0.00 0.00 0.00 0.00 1.00 27.48 0.67 27.49
November 0.83 18.81 0.00 18.81 0.00 18.81 0.00 18.81
December 4.17 18.41 0.00 18.41 0.00 18.41 0.00 18.41
                 
Annual Sum or Average 22.33 17.42 2.00 17.24 46.00 24.06 20.33 24.93
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 11.83 18.81 1.00 18.81 14.50 27.86 5.67 27.88



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: GROUNDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: MIDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: TOPFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: DATACENTER_BOT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: DATACENTER_MID_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 3.17 27.61 3.17 27.61
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   3.17 27.61 3.17 27.61
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 3.17 27.61 3.17 27.61



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: DATACENTER_TOP_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 2.67 27.61 2.67 27.61
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   2.67 27.61 2.67 27.61
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 2.67 27.61 2.67 27.61



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: DATACENTER_BASEMENT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: ComfortReportSimple55Monthly

For: BASEMENT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 238.50 23.99 69.67 24.31 0.00 24.31
February 169.83 24.21 90.17 24.60 12.67 24.70
March 84.67 24.00 171.17 24.65 2.67 24.65
April 67.83 24.45 255.33 24.77 35.83 24.78
May 151.17 24.66 431.50 24.59 143.83 24.61
June 238.50 24.61 450.00 24.56 238.50 24.57
July 277.33 25.15 497.00 24.83 277.33 24.91
August 234.67 25.15 514.00 24.73 234.67 24.83
September 151.17 25.38 473.67 24.81 151.17 24.92
October 40.33 25.56 316.83 25.07 37.50 25.13
November 53.50 24.85 210.67 25.28 22.17 25.34
December 112.83 24.00 166.33 24.90 1.17 24.90
             
Annual Sum or Average 1820.33 24.67 3646.33 24.74 1157.50 24.80
Minimum of Months 40.33 23.99 69.67 24.31 0.00 24.31
Maximum of Months 277.33 25.56 514.00 25.28 277.33 25.34



Table of Contents

Report: ComfortReportSimple55Monthly

For: CORE_BOTTOM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 344.83 23.86 43.50 23.96 14.33 24.02
February 194.83 23.91 65.50 24.15 5.00 24.18
March 57.00 23.98 172.17 24.44 0.00 24.44
April 10.67 24.02 267.50 24.40 0.00 24.40
May 8.67 23.96 437.17 24.30 0.00 24.30
June 0.00 0.00 451.33 24.22 0.00 24.22
July 0.00 0.00 497.00 24.23 0.00 24.23
August 0.00 0.00 514.00 24.18 0.00 24.18
September 2.33 26.36 471.17 24.34 2.33 24.35
October 16.00 25.37 293.33 24.66 10.50 24.71
November 59.50 24.01 191.00 24.66 0.50 24.67
December 128.33 23.99 134.67 24.55 0.00 24.55
             
Annual Sum or Average 822.17 23.95 3538.33 24.31 32.67 24.32
Minimum of Months 0.00 0.00 43.50 23.96 0.00 24.02
Maximum of Months 344.83 26.36 514.00 24.66 14.33 24.71



Table of Contents

Report: ComfortReportSimple55Monthly

For: CORE_MID

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 493.67 22.50 21.67 22.48 21.67 22.46
February 414.17 23.04 21.50 23.07 13.83 23.09
March 259.83 23.67 102.50 23.84 0.00 23.84
April 97.17 23.69 191.17 24.16 0.00 24.16
May 18.67 23.76 403.50 24.18 0.00 24.18
June 11.83 23.73 435.17 24.19 0.00 24.19
July 0.00 0.00 493.33 24.20 0.00 24.20
August 0.00 0.00 513.83 24.16 0.00 24.16
September 10.50 24.91 439.50 24.25 7.00 24.28
October 132.33 23.63 194.50 24.04 14.50 24.07
November 323.83 23.67 58.83 23.76 9.50 23.77
December 441.17 23.16 24.83 23.21 0.00 23.21
             
Annual Sum or Average 2203.17 23.19 2900.33 23.77 66.50 23.76
Minimum of Months 0.00 0.00 21.50 22.48 0.00 22.46
Maximum of Months 493.67 24.91 513.83 24.25 21.67 24.28



Table of Contents

Report: ComfortReportSimple55Monthly

For: CORE_TOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 500.50 20.97 224.33 20.68 224.33 20.53
February 440.17 21.79 100.67 21.51 100.00 21.32
March 376.17 22.94 84.67 23.08 11.00 23.04
April 189.50 23.30 158.00 23.74 4.00 23.74
May 40.50 23.61 395.50 24.14 0.67 24.14
June 16.67 23.66 434.67 24.22 0.00 24.22
July 3.83 23.14 485.50 24.26 0.00 24.26
August 0.00 0.00 514.00 24.21 0.00 24.21
September 38.00 23.55 403.67 24.17 9.83 24.19
October 300.67 22.96 130.33 23.26 19.67 23.27
November 443.50 22.47 53.50 22.45 34.83 22.38
December 484.67 21.53 136.00 21.32 132.33 21.18
             
Annual Sum or Average 2834.17 22.15 3120.83 22.90 536.67 22.71
Minimum of Months 0.00 0.00 53.50 20.68 0.00 20.53
Maximum of Months 500.50 23.66 514.00 24.26 224.33 24.26



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_BOT_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 476.83 21.77 122.00 21.59 119.83 21.46
February 402.83 22.43 66.50 22.28 55.50 22.11
March 304.17 23.42 96.33 23.61 0.00 23.61
April 119.00 23.54 206.67 24.02 0.00 24.02
May 28.00 23.76 411.17 24.30 0.00 24.30
June 4.50 23.93 454.00 24.36 0.33 24.36
July 8.67 26.72 497.00 24.48 8.67 24.52
August 5.50 26.70 514.00 24.37 5.50 24.39
September 22.00 25.09 428.83 24.41 14.50 24.46
October 202.83 23.40 181.50 23.83 0.33 23.83
November 352.83 23.31 71.00 23.46 0.00 23.46
December 433.17 22.83 36.17 22.91 2.33 22.90
             
Annual Sum or Average 2360.33 22.84 3085.17 23.58 207.00 23.51
Minimum of Months 4.50 21.77 36.17 21.59 0.00 21.46
Maximum of Months 476.83 26.72 514.00 24.48 119.83 24.52



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_BOT_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 476.33 21.99 85.33 21.80 85.33 21.65
February 373.50 22.40 39.00 22.40 25.67 22.30
March 264.17 23.26 110.33 23.59 0.00 23.59
April 110.67 23.35 240.33 23.99 1.00 24.00
May 34.67 25.39 431.33 24.52 19.33 24.61
June 21.67 26.32 466.33 24.48 18.17 24.57
July 41.17 26.75 493.17 24.64 41.17 24.79
August 27.00 26.75 514.00 24.45 27.00 24.56
September 46.33 24.90 430.83 24.47 25.17 24.56
October 166.50 23.20 211.00 23.90 1.67 23.91
November 327.67 23.19 63.83 23.40 0.00 23.40
December 447.67 22.70 27.83 22.74 5.83 22.72
             
Annual Sum or Average 2337.33 22.94 3113.33 23.70 250.33 23.71
Minimum of Months 21.67 21.99 27.83 21.80 0.00 21.65
Maximum of Months 476.33 26.75 514.00 24.64 85.33 24.79



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_BOT_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 413.00 22.15 91.83 22.04 75.50 21.87
February 325.50 22.59 53.50 22.71 23.17 22.61
March 198.17 23.36 153.17 23.90 0.50 23.90
April 95.83 23.51 262.83 24.16 1.17 24.18
May 31.33 24.00 417.83 24.35 3.67 24.37
June 13.17 24.95 446.83 24.39 5.83 24.42
July 25.00 26.70 497.00 24.57 25.00 24.67
August 24.33 26.81 514.00 24.51 24.33 24.61
September 44.33 25.73 444.00 24.60 34.83 24.72
October 132.67 23.69 271.17 24.28 18.33 24.40
November 230.83 23.44 132.67 23.92 7.67 23.98
December 334.83 22.86 61.33 23.11 4.83 23.08
             
Annual Sum or Average 1869.00 23.08 3346.17 23.90 224.83 23.90
Minimum of Months 13.17 22.15 53.50 22.04 0.50 21.87
Maximum of Months 413.00 26.81 514.00 24.60 75.50 24.72



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_BOT_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 427.83 22.37 41.67 22.43 17.17 22.37
February 255.83 23.03 84.50 23.45 7.00 23.46
March 43.83 24.37 266.33 24.75 7.83 24.81
April 40.00 26.52 399.83 24.92 34.50 25.06
May 24.50 26.18 470.83 24.63 19.50 24.72
June 43.17 26.92 484.17 24.76 43.17 24.92
July 81.33 26.80 497.00 24.98 81.33 25.20
August 87.33 26.76 514.00 24.90 87.33 25.13
September 47.17 26.73 478.33 24.75 46.00 24.92
October 43.17 24.89 326.00 24.79 17.00 24.88
November 98.50 23.98 208.00 24.66 8.33 24.72
December 147.83 23.78 133.50 24.41 0.33 24.42
             
Annual Sum or Average 1340.50 23.97 3904.17 24.48 369.50 24.62
Minimum of Months 24.50 22.37 41.67 22.43 0.33 22.37
Maximum of Months 427.83 26.92 514.00 24.98 87.33 25.20



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_MID_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 502.00 20.51 360.83 20.37 360.83 20.31
February 451.67 21.21 164.00 20.92 164.00 20.75
March 433.83 22.45 86.00 22.54 28.00 22.46
April 243.00 22.97 133.67 23.43 1.50 23.43
May 63.83 23.51 369.00 24.15 2.67 24.16
June 18.67 24.76 433.83 24.37 8.83 24.41
July 23.83 25.57 491.50 24.50 21.67 24.55
August 12.17 25.97 514.00 24.38 12.17 24.42
September 75.67 24.01 383.17 24.24 28.50 24.32
October 369.17 22.63 107.83 22.96 10.00 22.99
November 467.67 21.99 65.50 21.90 55.00 21.78
December 494.17 21.01 232.67 20.83 230.50 20.73
             
Annual Sum or Average 3155.67 21.84 3342.00 22.60 923.67 22.37
Minimum of Months 12.17 20.51 65.50 20.37 1.50 20.31
Maximum of Months 502.00 25.97 514.00 24.50 360.83 24.55



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_MID_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 427.00 20.67 269.83 20.49 269.83 20.41
February 365.50 21.44 129.67 21.19 124.83 21.00
March 308.50 22.72 62.00 22.93 5.50 22.90
April 135.50 23.09 170.83 23.90 2.67 23.93
May 58.00 24.72 337.67 24.56 23.50 24.69
June 35.67 26.32 390.67 24.70 31.17 24.84
July 67.67 26.41 413.33 24.92 63.83 25.12
August 42.17 26.67 433.00 24.72 42.17 24.88
September 73.83 24.49 337.50 24.49 36.33 24.62
October 244.00 22.67 131.83 23.28 9.67 23.31
November 385.33 22.29 38.83 22.28 22.33 22.19
December 417.50 21.18 152.33 20.98 151.33 20.85
             
Annual Sum or Average 2560.67 22.20 2867.50 22.99 783.17 22.86
Minimum of Months 35.67 20.67 38.83 20.49 2.67 20.41
Maximum of Months 427.00 26.67 433.00 24.92 269.83 25.12



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_MID_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 439.67 21.53 168.83 21.28 159.33 21.08
February 364.67 21.99 84.67 21.94 65.50 21.76
March 263.17 22.96 127.83 23.49 0.00 23.49
April 147.50 23.15 211.17 23.93 2.67 23.95
May 49.17 23.63 382.83 24.25 4.00 24.27
June 27.33 24.93 434.00 24.40 13.67 24.46
July 34.83 26.02 491.83 24.58 33.17 24.68
August 32.33 26.52 514.00 24.56 32.33 24.67
September 73.67 24.86 429.00 24.52 41.00 24.65
October 194.83 23.23 233.67 23.96 26.00 24.08
November 303.50 22.98 94.67 23.40 13.67 23.43
December 385.67 22.00 96.00 22.00 61.00 21.83
             
Annual Sum or Average 2316.33 22.61 3268.50 23.49 452.33 23.41
Minimum of Months 27.33 21.53 84.67 21.28 0.00 21.08
Maximum of Months 439.67 26.52 514.00 24.58 159.33 24.68



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_MID_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 500.50 20.99 256.83 20.77 256.83 20.66
February 424.50 21.59 117.67 21.38 110.83 21.19
March 322.33 22.81 117.83 23.24 0.00 23.24
April 138.33 23.33 262.67 24.10 6.50 24.15
May 38.83 24.59 424.83 24.43 14.67 24.50
June 32.50 25.97 460.33 24.60 25.00 24.70
July 50.83 26.60 492.67 24.77 50.83 24.93
August 37.00 26.82 514.00 24.67 37.00 24.80
September 73.83 24.68 423.67 24.49 38.17 24.61
October 261.83 22.85 169.67 23.46 11.50 23.51
November 403.50 22.39 58.00 22.49 20.17 22.43
December 479.50 21.52 128.83 21.39 115.50 21.26
             
Annual Sum or Average 2763.50 22.27 3427.00 23.17 687.00 23.05
Minimum of Months 32.50 20.99 58.00 20.77 0.00 20.66
Maximum of Months 500.50 26.82 514.00 24.77 256.83 24.93



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_TOP_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 502.00 20.01 425.00 19.89 425.00 19.85
February 454.00 20.74 259.50 20.50 259.50 20.38
March 447.50 21.77 132.67 21.78 81.33 21.60
April 278.33 22.50 130.83 22.91 20.17 22.83
May 95.50 23.18 352.83 24.04 5.67 24.05
June 34.67 24.83 432.50 24.43 16.83 24.50
July 45.50 25.74 484.67 24.60 40.00 24.71
August 25.33 26.31 512.83 24.48 25.33 24.56
September 104.50 23.47 342.83 24.10 29.83 24.18
October 395.67 21.95 110.67 22.28 32.00 22.27
November 480.00 21.18 193.83 20.95 187.83 20.80
December 495.67 20.32 362.33 20.15 362.33 20.09
             
Annual Sum or Average 3358.67 21.36 3740.50 22.11 1485.83 21.83
Minimum of Months 25.33 20.01 110.67 19.89 5.67 19.85
Maximum of Months 502.00 26.31 512.83 24.60 425.00 24.71



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_TOP_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 502.00 20.19 400.50 20.06 400.50 20.01
February 447.00 21.11 208.50 20.77 208.50 20.60
March 403.00 22.33 102.33 22.44 36.00 22.31
April 177.00 22.73 207.17 23.57 8.00 23.55
May 86.00 24.41 401.33 24.45 32.33 24.59
June 42.67 26.18 463.83 24.63 35.50 24.77
July 73.83 26.21 480.67 24.82 65.83 25.01
August 46.33 26.73 513.00 24.66 46.33 24.82
September 92.67 23.90 389.83 24.31 37.83 24.43
October 301.50 22.11 147.83 22.68 24.83 22.64
November 466.00 21.54 131.83 21.35 120.67 21.18
December 492.83 20.50 311.17 20.28 311.17 20.18
             
Annual Sum or Average 3130.83 21.72 3758.00 22.51 1327.50 22.29
Minimum of Months 42.67 20.19 102.33 20.06 8.00 20.01
Maximum of Months 502.00 26.73 513.00 24.82 400.50 25.01



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_TOP_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 482.00 20.98 261.33 20.61 260.67 20.42
February 392.50 21.42 168.00 21.22 152.67 21.00
March 318.83 22.38 138.83 22.74 34.33 22.59
April 202.67 22.76 204.83 23.51 14.00 23.47
May 84.33 23.46 369.00 24.18 10.67 24.22
June 44.33 24.84 432.67 24.45 21.00 24.54
July 53.17 25.97 485.00 24.66 47.83 24.79
August 35.83 26.59 514.00 24.60 35.83 24.72
September 97.50 24.32 412.50 24.43 45.00 24.57
October 243.00 22.52 209.83 23.37 30.67 23.43
November 368.00 22.16 115.67 22.27 63.83 22.10
December 445.00 21.32 201.17 21.03 178.67 20.78
             
Annual Sum or Average 2767.17 22.11 3512.83 22.93 895.17 22.74
Minimum of Months 35.83 20.98 115.67 20.61 10.67 20.42
Maximum of Months 482.00 26.59 514.00 24.66 260.67 24.79



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_TOP_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 501.33 20.40 346.33 20.20 346.33 20.11
February 435.17 21.11 178.67 20.84 175.83 20.68
March 358.67 22.14 129.50 22.46 34.33 22.34
April 189.33 22.83 234.33 23.68 13.83 23.69
May 72.67 23.89 397.33 24.34 18.33 24.42
June 40.83 25.67 455.17 24.60 28.50 24.72
July 60.50 26.29 486.83 24.77 55.67 24.94
August 44.33 26.81 514.00 24.70 44.33 24.85
September 99.17 24.01 395.50 24.36 39.17 24.49
October 315.17 22.25 150.67 22.89 16.67 22.92
November 446.50 21.70 117.83 21.56 101.00 21.39
December 485.17 20.80 259.33 20.57 255.33 20.45
             
Annual Sum or Average 3048.83 21.78 3665.50 22.65 1129.33 22.45
Minimum of Months 40.83 20.40 117.83 20.20 13.83 20.11
Maximum of Months 501.33 26.81 514.00 24.77 346.33 24.94



Table of Contents

Report: ComfortReportSimple55Monthly

For: GROUNDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00
             
Annual Sum or Average 0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: ComfortReportSimple55Monthly

For: MIDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00
             
Annual Sum or Average 0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: ComfortReportSimple55Monthly

For: TOPFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00
             
Annual Sum or Average 0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: ComfortReportSimple55Monthly

For: DATACENTER_BOT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 499.50 27.00 0.00 27.00
February 1.00 27.00 454.00 27.00 1.00 27.00
March 7.83 27.00 514.00 27.00 7.83 27.00
April 84.83 27.00 485.00 27.00 84.83 27.00
May 0.00 0.00 508.00 27.00 0.00 27.00
June 12.83 27.00 496.00 27.00 12.83 27.00
July 170.17 27.00 497.00 27.00 170.17 27.00
August 382.00 27.02 514.00 27.02 382.00 27.02
September 1.33 27.00 485.00 27.00 1.33 27.00
October 4.50 27.00 502.00 27.00 4.50 27.00
November 8.33 27.00 489.00 27.00 8.33 27.00
December 1.83 27.00 497.00 27.00 1.83 27.00
             
Annual Sum or Average 674.67 27.01 5940.50 27.00 674.67 27.00
Minimum of Months 0.00 0.00 454.00 27.00 0.00 27.00
Maximum of Months 382.00 27.02 514.00 27.02 382.00 27.02



Table of Contents

Report: ComfortReportSimple55Monthly

For: DATACENTER_MID_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 17.17 26.09 343.83 26.95 0.00 26.95
February 0.00 0.00 391.50 27.00 0.00 27.00
March 0.00 0.00 514.00 27.00 0.00 27.00
April 0.50 27.00 485.00 27.00 0.50 27.00
May 0.00 0.00 508.00 27.00 0.00 27.00
June 0.00 0.00 496.00 27.00 0.00 27.00
July 0.00 0.00 497.00 27.00 0.00 27.00
August 35.33 27.36 514.00 27.05 35.33 27.07
September 0.00 0.00 485.00 27.00 0.00 27.00
October 0.00 0.00 502.00 27.00 0.00 27.00
November 0.00 0.00 489.00 27.00 0.00 27.00
December 0.00 0.00 485.33 27.00 0.00 27.00
             
Annual Sum or Average 53.00 26.94 5710.67 27.00 35.83 27.00
Minimum of Months 0.00 0.00 343.83 26.95 0.00 26.95
Maximum of Months 35.33 27.36 514.00 27.05 35.33 27.07



Table of Contents

Report: ComfortReportSimple55Monthly

For: DATACENTER_TOP_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 184.00 24.92 206.33 25.80 19.83 25.65
February 26.00 27.00 327.00 27.00 0.00 27.00
March 0.00 0.00 492.33 27.00 0.00 27.00
April 2.17 27.00 485.00 27.00 2.17 27.00
May 0.00 0.00 508.00 27.00 0.00 27.00
June 4.67 27.00 496.00 27.00 4.67 27.00
July 28.67 27.00 497.00 27.00 28.67 27.00
August 77.83 27.16 514.00 27.04 77.83 27.06
September 0.83 27.00 485.00 27.00 0.83 27.00
October 0.00 0.00 502.00 27.00 0.00 27.00
November 0.00 0.00 446.67 27.00 0.00 27.00
December 9.33 27.00 395.17 27.00 0.00 27.00
             
Annual Sum or Average 333.50 25.89 5354.50 26.92 134.00 26.91
Minimum of Months 0.00 0.00 206.33 25.80 0.00 25.65
Maximum of Months 184.00 27.16 514.00 27.04 77.83 27.06



Table of Contents

Report: ComfortReportSimple55Monthly

For: DATACENTER_BASEMENT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 434.50 27.00 502.00 27.00 434.50 27.00
February 454.00 27.00 454.00 27.00 454.00 27.00
March 514.00 27.00 514.00 27.00 514.00 27.00
April 485.00 27.00 485.00 27.00 485.00 27.00
May 508.00 27.00 508.00 27.00 508.00 27.00
June 496.00 27.00 496.00 27.00 496.00 27.00
July 497.00 27.00 497.00 27.00 497.00 27.00
August 514.00 27.00 514.00 27.00 514.00 27.00
September 485.00 27.00 485.00 27.00 485.00 27.00
October 502.00 27.00 502.00 27.00 502.00 27.00
November 489.00 27.00 489.00 27.00 489.00 27.00
December 497.00 27.00 497.00 27.00 497.00 27.00
             
Annual Sum or Average 5875.50 27.00 5943.00 27.00 5875.50 27.00
Minimum of Months 434.50 27.00 454.00 27.00 434.50 27.00
Maximum of Months 514.00 27.00 514.00 27.00 514.00 27.00



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: DATACENTER_BOT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 27.00007 21.58591 0.71881 16.07338
February 454.00000 27.00011 24.11929 0.80596 18.86996
March 514.00000 27.00021 28.77272 0.91957 22.94670
April 485.00000 27.00013 32.13839 0.99233 25.83940
May 508.00000 27.00067 36.40282 0.26524 6.51062
June 496.00000 27.00159 36.98100 0.33317 7.34863
July 497.00000 27.00121 37.20550 0.38751 8.16181
August 514.00000 27.01858 37.05546 0.43601 9.00628
September 485.00000 27.00059 38.19849 0.29113 6.81050
October 502.00000 27.00070 33.44250 0.93718 23.58909
November 489.00000 27.00018 27.27255 0.90340 22.32380
December 497.00000 27.00005 24.71947 0.89230 21.91606
           
Annual Sum or Average 5943.00000 27.00207 31.54496 0.65527 15.74186
Minimum of Months 454.00000 27.00005 21.58591 0.26524 6.51062
Maximum of Months 514.00000 27.01858 38.19849 0.99233 25.83940



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: DATACENTER_MID_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 26.94598 21.75740 0.58356 12.45410
February 454.00000 27.00011 24.11888 0.67562 14.84641
March 514.00000 27.00019 28.74069 0.81502 19.15627
April 485.00000 27.00012 32.10187 0.89276 21.90253
May 508.00000 27.00050 36.55603 0.21043 5.98475
June 496.00000 27.00153 37.03093 0.26029 6.45852
July 497.00000 27.00114 37.22867 0.29052 6.79341
August 514.00000 27.03230 37.04604 0.32348 7.23644
September 485.00000 27.00043 38.42682 0.22764 6.14486
October 502.00000 27.00066 33.47603 0.84894 20.28415
November 489.00000 27.00017 27.24555 0.77209 17.70425
December 497.00000 27.00005 24.69416 0.70591 15.64522
           
Annual Sum or Average 5943.00000 26.99864 31.58918 0.54908 12.85492
Minimum of Months 454.00000 26.94598 21.75740 0.21043 5.98475
Maximum of Months 514.00000 27.03230 38.42682 0.89276 21.90253



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: DATACENTER_TOP_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 26.16980 23.02673 0.36667 10.00724
February 454.00000 27.00020 24.15172 0.60957 13.19418
March 514.00000 27.00020 28.76344 0.76845 17.72782
April 485.00000 27.00013 32.12266 0.87075 21.17417
May 508.00000 27.00055 36.52819 0.21060 6.06202
June 496.00000 27.00159 37.01983 0.27582 6.68528
July 497.00000 27.00119 37.23928 0.30940 7.08614
August 514.00000 27.02549 37.06740 0.34114 7.52180
September 485.00000 27.00042 38.48057 0.22075 6.15609
October 502.00000 27.00066 33.54528 0.80718 18.91751
November 489.00000 27.00018 27.27844 0.69898 15.54576
December 497.00000 27.00006 24.71333 0.61940 13.33156
           
Annual Sum or Average 5943.00000 26.93251 31.71654 0.50697 11.92811
Minimum of Months 454.00000 26.16980 23.02673 0.21060 6.06202
Maximum of Months 514.00000 27.02549 38.48057 0.87075 21.17417



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: DATACENTER_BASEMENT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 27.00000 39.75035 1.07825 29.54055
February 454.00000 27.00000 39.48044 1.24589 37.52673
March 514.00000 27.00000 39.36472 1.40095 45.56356
April 485.00000 27.00000 39.36650 1.52917 52.48691
May 508.00000 27.00000 39.52657 0.50180 10.29540
June 496.00000 27.00000 39.31768 0.75067 16.87612
July 497.00000 27.00000 39.37192 0.96791 24.79655
August 514.00000 27.00000 39.27191 1.17143 33.86718
September 485.00000 27.00000 39.41023 0.59272 12.39064
October 502.00000 27.00000 39.37277 1.31660 41.12855
November 489.00000 27.00000 39.33440 1.45194 48.29863
December 497.00000 27.00000 39.43336 1.56391 54.37951
           
Annual Sum or Average 5943.00000 27.00000 39.41640 1.12985 33.88443
Minimum of Months 454.00000 27.00000 39.27191 0.50180 10.29540
Maximum of Months 514.00000 27.00000 39.75035 1.56391 54.37951



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: BASEMENT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 24.40813 23.07229 0.31227 7.54602
February 454.00000 24.43743 26.49332 0.34873 8.23703
March 514.00000 24.42238 32.65369 0.40006 8.78225
April 485.00000 24.48815 39.88507 0.46330 10.03337
May 508.00000 24.50340 52.93231 -0.2981 7.86896
June 496.00000 24.49153 56.65865 -0.2581 7.32730
July 497.00000 24.64472 61.97162 -0.1624 7.03923
August 514.00000 24.53645 60.90385 -0.1906 7.05376
September 485.00000 24.61422 56.50057 -0.2012 7.46574
October 502.00000 24.64692 41.77471 0.54052 11.99707
November 489.00000 24.64582 30.13632 0.45517 10.18769
December 497.00000 24.59618 26.50099 0.40739 9.26256
           
Annual Sum or Average 5943.00000 24.53639 42.59072 0.14911 8.56345
Minimum of Months 454.00000 24.40813 23.07229 -0.2981 7.03923
Maximum of Months 514.00000 24.64692 61.97162 0.54052 11.99707



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: CORE_BOTTOM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 23.98366 28.21401 0.24780 7.16868
February 454.00000 24.13636 28.53052 0.30311 7.40357
March 514.00000 24.26073 33.32717 0.39452 8.59719
April 485.00000 24.25322 40.16946 0.45189 9.54811
May 508.00000 24.27045 51.29224 -0.3443 7.95112
June 496.00000 24.20236 52.41179 -0.3372 7.60948
July 497.00000 24.22921 55.83629 -0.2935 6.97431
August 514.00000 24.18153 55.45634 -0.2989 6.99025
September 485.00000 24.32511 54.05562 -0.2968 7.38779
October 502.00000 24.37090 42.62763 0.48873 10.45215
November 489.00000 24.38808 31.41302 0.40874 8.95547
December 497.00000 24.38449 28.38508 0.37498 8.52909
           
Annual Sum or Average 5943.00000 24.24907 41.91838 0.08917 8.13236
Minimum of Months 454.00000 23.98366 28.21401 -0.3443 6.97431
Maximum of Months 514.00000 24.38808 55.83629 0.48873 10.45215



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: CORE_MID

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 22.52633 31.73830 -0.1210 6.22113
February 454.00000 23.12949 31.96348 0.04371 6.06859
March 514.00000 23.91041 34.92907 0.28546 7.13998
April 485.00000 24.10664 41.39040 0.38854 8.53604
May 508.00000 24.15101 51.98429 -0.4045 8.78524
June 496.00000 24.16461 53.18934 -0.3782 8.34293
July 497.00000 24.19293 56.93195 -0.3430 7.72445
August 514.00000 24.16080 56.72954 -0.3497 7.77151
September 485.00000 24.19229 54.94681 -0.3670 8.21739
October 502.00000 24.01836 44.29292 0.37977 8.34596
November 489.00000 23.82343 33.77145 0.24305 6.68738
December 497.00000 23.25184 32.46651 0.07540 5.80631
           
Annual Sum or Average 5943.00000 23.80681 43.79108 -0.0471 7.48000
Minimum of Months 454.00000 22.52633 31.73830 -0.4045 5.80631
Maximum of Months 514.00000 24.19293 56.93195 0.38854 8.78524



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: CORE_TOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 20.97750 33.02193 -0.5200 13.54653
February 454.00000 21.85421 34.45823 -0.2756 9.48203
March 514.00000 23.23523 36.92264 0.11494 6.79931
April 485.00000 23.80430 42.32547 0.31225 7.83426
May 508.00000 24.11364 51.93258 -0.4113 9.06412
June 496.00000 24.20586 52.70927 -0.3500 8.01076
July 497.00000 24.24273 56.44261 -0.3088 7.35316
August 514.00000 24.21306 56.29825 -0.3150 7.32466
September 485.00000 24.10604 55.40419 -0.3942 8.83530
October 502.00000 23.39257 46.51948 0.22242 7.08686
November 489.00000 22.60951 36.71412 -0.0608 6.83524
December 497.00000 21.58864 35.66408 -0.3389 9.58380
           
Annual Sum or Average 5943.00000 23.20555 44.95104 -0.1937 8.47136
Minimum of Months 454.00000 20.97750 33.02193 -0.5200 6.79931
Maximum of Months 514.00000 24.24273 56.44261 0.31225 13.54653



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_BOT_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 21.88024 28.05288 -0.2874 8.63458
February 454.00000 22.61883 29.57664 -0.0873 7.39147
March 514.00000 23.70236 33.83212 0.22556 6.92174
April 485.00000 24.03297 40.05792 0.37393 8.55569
May 508.00000 24.26612 50.44290 -0.3513 8.33625
June 496.00000 24.33577 51.15075 -0.2665 7.07100
July 497.00000 24.43939 54.46506 -0.1941 6.53741
August 514.00000 24.34077 54.22611 -0.2201 6.56139
September 485.00000 24.30627 53.58545 -0.3158 7.90775
October 502.00000 23.88481 43.40844 0.34006 8.13360
November 489.00000 23.54181 32.54437 0.16604 6.64521
December 497.00000 22.98395 29.61705 0.00110 6.23994
           
Annual Sum or Average 5943.00000 23.70197 41.84404 -0.0517 7.40877
Minimum of Months 454.00000 21.88024 28.05288 -0.3513 6.23994
Maximum of Months 514.00000 24.43939 54.46506 0.37393 8.63458



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_BOT_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 22.09935 27.63235 -0.2319 7.97240
February 454.00000 22.74199 29.20384 -0.0460 7.24204
March 514.00000 23.70918 33.57877 0.24813 7.27101
April 485.00000 23.98721 39.91632 0.39364 8.99072
May 508.00000 24.35853 49.89204 -0.2697 7.94291
June 496.00000 24.36964 50.85796 -0.2090 6.87013
July 497.00000 24.45254 54.25372 -0.1475 6.73560
August 514.00000 24.33334 54.10046 -0.1893 6.65627
September 485.00000 24.32462 53.23348 -0.2646 7.75360
October 502.00000 23.91153 42.99761 0.36950 8.88768
November 489.00000 23.51889 32.39653 0.17246 6.77184
December 497.00000 22.83875 29.69762 -0.0246 6.22453
           
Annual Sum or Average 5943.00000 23.72765 41.57765 -0.0170 7.44177
Minimum of Months 454.00000 22.09935 27.63235 -0.2697 6.22453
Maximum of Months 514.00000 24.45254 54.25372 0.39364 8.99072



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_BOT_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 22.55439 27.05378 -0.1212 8.08733
February 454.00000 23.09737 28.69772 0.04396 7.63429
March 514.00000 23.95418 32.95231 0.31569 8.27170
April 485.00000 24.12611 39.56693 0.41858 9.50173
May 508.00000 24.29111 50.25784 -0.3289 8.23315
June 496.00000 24.33980 51.11757 -0.2631 7.19225
July 497.00000 24.46258 54.36650 -0.1804 6.62579
August 514.00000 24.39938 53.90099 -0.1708 6.46729
September 485.00000 24.41327 52.97901 -0.2328 7.47998
October 502.00000 24.13589 42.23185 0.44435 10.39752
November 489.00000 23.92452 31.21112 0.29106 8.35097
December 497.00000 23.33085 28.62548 0.10829 6.93739
           
Annual Sum or Average 5943.00000 23.92477 41.17989 0.02619 7.93062
Minimum of Months 454.00000 22.55439 27.05378 -0.3289 6.46729
Maximum of Months 514.00000 24.46258 54.36650 0.44435 10.39752



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_BOT_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 22.66384 26.19423 -0.0794 6.97081
February 454.00000 23.62269 27.09726 0.18722 7.58562
March 514.00000 24.43518 31.58625 0.48263 10.76787
April 485.00000 24.62401 38.08077 0.62834 14.31953
May 508.00000 24.50993 49.29544 -0.1709 6.97140
June 496.00000 24.55148 50.17754 -0.0703 6.49913
July 497.00000 24.67898 53.32587 0.03046 6.80061
August 514.00000 24.58236 53.01607 0.03736 6.65403
September 485.00000 24.54570 52.36229 -0.1388 6.97952
October 502.00000 24.48016 41.14519 0.54638 12.20843
November 489.00000 24.40765 29.99989 0.43279 9.97762
December 497.00000 24.30788 26.48193 0.36423 8.62026
           
Annual Sum or Average 5943.00000 24.28802 40.00027 0.18681 8.69342
Minimum of Months 454.00000 22.66384 26.19423 -0.1709 6.49913
Maximum of Months 514.00000 24.67898 53.32587 0.62834 14.31953



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_MID_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 20.51032 30.84679 -0.6699 16.64764
February 454.00000 21.22565 32.31459 -0.4526 12.25054
March 514.00000 22.69601 36.24450 -0.0245 6.93521
April 485.00000 23.55593 41.87662 0.23954 7.58217
May 508.00000 24.10506 51.38845 -0.4242 9.61900
June 496.00000 24.31558 51.99514 -0.2965 7.55868
July 497.00000 24.43472 55.78077 -0.2239 6.86392
August 514.00000 24.34573 55.70784 -0.2532 6.89685
September 485.00000 24.12293 55.05555 -0.3973 9.24330
October 502.00000 22.98810 46.35318 0.11679 6.79319
November 489.00000 22.07116 36.04797 -0.1928 7.59721
December 497.00000 21.02225 33.30532 -0.4904 11.92447
           
Annual Sum or Average 5943.00000 22.96267 44.00117 -0.2548 9.13470
Minimum of Months 454.00000 20.51032 30.84679 -0.6699 6.79319
Maximum of Months 514.00000 24.43472 55.78077 0.23954 16.64764



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_MID_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 427.00000 20.66561 29.42389 -0.6213 14.94697
February 385.00000 21.59867 30.93779 -0.3509 10.80234
March 433.00000 23.13791 34.26519 0.09194 6.90504
April 410.00000 23.90757 40.25764 0.34932 8.89137
May 430.00000 24.34978 50.00890 -0.2981 8.81009
June 418.00000 24.51687 51.07892 -0.1846 7.18091
July 422.00000 24.65302 54.81204 -0.1045 7.22581
August 433.00000 24.53255 54.88278 -0.1489 6.91437
September 410.00000 24.28330 54.14894 -0.3028 8.79554
October 427.00000 23.34636 44.51625 0.21680 7.84265
November 417.00000 22.43154 34.26846 -0.1004 6.91541
December 422.00000 21.21136 32.00975 -0.4350 10.58359
           
Annual Sum or Average 5034.00000 23.22911 42.62511 -0.1566 8.80309
Minimum of Months 385.00000 20.66561 29.42389 -0.6213 6.90504
Maximum of Months 433.00000 24.65302 54.88278 0.34932 14.94697



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_MID_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 21.90414 28.82279 -0.2948 10.74909
February 454.00000 22.47341 30.24729 -0.1179 8.91800
March 514.00000 23.62674 34.00563 0.22692 7.88400
April 485.00000 23.93801 40.57438 0.35579 8.92786
May 508.00000 24.18468 50.96470 -0.3790 9.04274
June 496.00000 24.32256 51.94146 -0.2903 7.63049
July 497.00000 24.47074 55.61812 -0.2042 6.90200
August 514.00000 24.43552 55.20503 -0.1896 6.71029
September 485.00000 24.33921 53.90689 -0.2697 8.08497
October 502.00000 23.85941 43.41716 0.37050 9.75304
November 489.00000 23.49811 32.75868 0.18158 7.97452
December 497.00000 22.51900 30.63473 -0.0966 8.21048
           
Annual Sum or Average 5943.00000 23.63940 42.43885 -0.0592 8.39347
Minimum of Months 454.00000 21.90414 28.82279 -0.3790 6.71029
Maximum of Months 514.00000 24.47074 55.61812 0.37050 10.74909



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_MID_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 21.00002 29.68307 -0.5248 12.83783
February 454.00000 21.77348 30.92767 -0.2961 9.94814
March 514.00000 23.35389 34.37735 0.16217 7.44584
April 485.00000 24.03688 40.27011 0.39903 9.68876
May 508.00000 24.31441 50.37876 -0.2897 8.08987
June 496.00000 24.45903 51.31624 -0.1837 7.02476
July 497.00000 24.56976 55.03933 -0.1124 6.85248
August 514.00000 24.51359 54.78366 -0.1201 6.68333
September 485.00000 24.31138 54.02485 -0.2735 8.21581
October 502.00000 23.50904 44.43950 0.26793 8.19312
November 489.00000 22.70565 34.23037 -0.0234 7.01385
December 497.00000 21.60318 31.89238 -0.3302 9.15845
           
Annual Sum or Average 5943.00000 23.35788 42.70595 -0.1095 8.41347
Minimum of Months 454.00000 21.00002 29.68307 -0.5248 6.68333
Maximum of Months 514.00000 24.56976 55.03933 0.39903 12.83783



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_TOP_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 20.00871 32.57281 -0.8400 23.29341
February 454.00000 20.74395 33.94942 -0.6090 16.07809
March 514.00000 22.05703 37.65871 -0.1901 8.87347
April 485.00000 23.18332 42.75720 0.14717 7.70147
May 508.00000 24.01124 51.54630 -0.4505 10.75160
June 496.00000 24.33127 51.69461 -0.2780 7.71357
July 497.00000 24.45904 55.53585 -0.1984 7.03504
August 514.00000 24.38271 55.45708 -0.2245 6.87017
September 485.00000 23.99081 55.72135 -0.4385 10.65338
October 502.00000 22.38118 48.26721 -0.0374 7.56580
November 489.00000 21.22746 38.00642 -0.4221 11.40558
December 497.00000 20.32835 35.15049 -0.7042 18.64255
           
Annual Sum or Average 5943.00000 22.60685 44.94374 -0.3522 11.34308
Minimum of Months 454.00000 20.00871 32.57281 -0.8400 6.87017
Maximum of Months 514.00000 24.45904 55.72135 0.14717 23.29341



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_TOP_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 20.18833 31.97943 -0.7743 20.59727
February 454.00000 21.15356 33.00099 -0.4878 13.87733
March 514.00000 22.69920 36.13944 -0.0180 7.62418
April 485.00000 23.67627 41.20245 0.30161 8.77110
May 508.00000 24.24983 50.38051 -0.3045 9.11384
June 496.00000 24.44895 50.97268 -0.1672 7.07936
July 497.00000 24.55248 54.79327 -0.0948 7.27571
August 514.00000 24.46879 54.73208 -0.1286 6.78540
September 485.00000 24.12574 54.70059 -0.3322 9.71259
October 502.00000 22.91470 46.36421 0.11135 8.00329
November 489.00000 21.64932 36.82280 -0.3033 9.36912
December 497.00000 20.52477 34.47181 -0.6342 16.39393
           
Annual Sum or Average 5943.00000 22.90178 43.87998 -0.2343 10.35090
Minimum of Months 454.00000 20.18833 31.97943 -0.7743 6.78540
Maximum of Months 514.00000 24.55248 54.79327 0.30161 20.59727



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_TOP_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 21.11717 30.90835 -0.5189 15.58003
February 454.00000 21.84639 32.05890 -0.2992 11.70189
March 514.00000 23.11291 35.31606 0.08967 8.32068
April 485.00000 23.63501 41.38640 0.27914 8.76694
May 508.00000 24.10331 51.10204 -0.4004 10.05278
June 496.00000 24.33014 51.66092 -0.2736 7.84077
July 497.00000 24.48377 55.40619 -0.1814 7.09658
August 514.00000 24.45661 54.99983 -0.1637 6.73192
September 485.00000 24.24093 54.44886 -0.2984 9.14943
October 502.00000 23.42123 45.00691 0.25327 9.49840
November 489.00000 22.71583 34.71383 -0.0294 8.64408
December 497.00000 21.62361 32.85014 -0.3451 12.21052
           
Annual Sum or Average 5943.00000 23.26817 43.41053 -0.1568 9.61584
Minimum of Months 454.00000 21.11717 30.90835 -0.5189 6.73192
Maximum of Months 514.00000 24.48377 55.40619 0.27914 15.58003



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_TOP_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%]
January 502.00000 20.40356 31.40068 -0.7077 18.77733
February 454.00000 21.24551 32.53114 -0.4503 12.98362
March 514.00000 22.77070 35.65601 0.01535 8.18448
April 485.00000 23.71067 41.03430 0.31963 9.36201
May 508.00000 24.20764 50.57281 -0.3168 9.04813
June 496.00000 24.44351 51.11059 -0.1736 7.27540
July 497.00000 24.55238 54.92494 -0.0984 7.07908
August 514.00000 24.51562 54.63301 -0.1006 6.75427
September 485.00000 24.17753 54.64987 -0.3121 9.42865
October 502.00000 22.96954 46.11778 0.13371 8.14023
November 489.00000 21.91407 35.99194 -0.2304 8.92089
December 497.00000 20.87089 33.62263 -0.5381 13.91899
           
Annual Sum or Average 5943.00000 22.99554 43.60573 -0.2034 9.96173
Minimum of Months 454.00000 20.40356 31.40068 -0.7077 6.75427
Maximum of Months 514.00000 24.55238 54.92494 0.31963 18.77733



Table of Contents

Report: ChillerReportMonthly

For: COOLSYS1 CHILLER1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

CHILLER ELECTRICITY ENERGY [J] CHILLER ELECTRICITY RATE {Maximum} [W] CHILLER ELECTRICITY RATE {TIMESTAMP} CHILLER ELECTRICITY ENERGY {HOURS NON-ZERO} [HOURS] CHILLER EVAPORATOR COOLING ENERGY [J] CHILLER EVAPORATOR COOLING RATE [] CHILLER CONDENSER HEAT TRANSFER ENERGY [J] CHILLER COP [W/W] CHILLER COP {Maximum} [W/W] CHILLER COP {TIMESTAMP} CHILLER PART LOAD RATIO [] CHILLER PART LOAD RATIO []
January 0.392243E+10 63386.54 31-JAN-15:50 72.73 0.179617E+11 0.00 0.218842E+11 0.44 6.18 31-JAN-15:50 0.00 0.00
February 0.136650E+11 100138.25 28-FEB-15:00 123.14 0.744382E+11 0.00 0.881032E+11 0.90 7.23 28-FEB-16:00 0.00 0.00
March 0.383374E+11 112317.77 30-MAR-12:50 262.51 0.223174E+12 0.00 0.261511E+12 1.84 7.31 30-MAR-11:00 0.00 0.00
April 0.681676E+11 122440.38 14-APR-13:40 399.43 0.419819E+12 0.00 0.487987E+12 3.04 7.38 14-APR-13:45 0.00 0.00
May 0.114447E+12 135247.60 31-MAY-05:03 474.18 0.735331E+12 0.00 0.849778E+12 3.86 7.76 31-MAY-05:03 0.00 0.00
June 0.151828E+12 161200.03 20-JUN-05:04 564.24 0.990923E+12 0.00 0.114275E+13 4.82 7.76 22-JUN-05:02 0.00 0.00
July 0.169625E+12 191574.98 27-JUL-05:04 655.92 0.108891E+13 0.00 0.125854E+13 5.26 7.71 24-JUL-05:03 0.00 0.00
August 0.182221E+12 177999.44 08-AUG-05:04 692.60 0.116792E+13 0.00 0.135014E+13 5.53 7.72 08-AUG-05:02 0.00 0.00
September 0.122729E+12 153711.93 07-SEP-05:02 479.25 0.795582E+12 0.00 0.918312E+12 4.06 7.75 11-SEP-05:02 0.00 0.00
October 0.608033E+11 134928.78 19-OCT-05:02 305.25 0.373414E+12 0.00 0.434217E+12 2.30 7.70 18-OCT-05:03 0.00 0.00
November 0.274277E+11 87172.14 02-NOV-14:00 200.78 0.150946E+12 0.00 0.178373E+12 1.41 7.03 02-NOV-14:00 0.00 0.00
December 0.769079E+10 80166.26 12-DEC-14:30 84.77 0.416589E+11 0.00 0.493497E+11 0.56 6.84 12-DEC-14:30 0.00 0.00
                         
Annual Sum or Average 0.960866E+12     4314.78 0.608008E+13 0.00 0.704094E+13 2.85     0.00 0.00
Minimum of Months 0.392243E+10 63386.54   72.73 0.179617E+11 0.00 0.218842E+11 0.44 6.18   0.00 0.00
Maximum of Months 0.182221E+12 191574.98   692.60 0.116792E+13 0.00 0.135014E+13 5.53 7.76   0.00 0.00



Table of Contents

Report: ChillerReportMonthly

For: COOLSYS1 CHILLER2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

CHILLER ELECTRICITY ENERGY [J] CHILLER ELECTRICITY RATE {Maximum} [W] CHILLER ELECTRICITY RATE {TIMESTAMP} CHILLER ELECTRICITY ENERGY {HOURS NON-ZERO} [HOURS] CHILLER EVAPORATOR COOLING ENERGY [J] CHILLER EVAPORATOR COOLING RATE [] CHILLER CONDENSER HEAT TRANSFER ENERGY [J] CHILLER COP [W/W] CHILLER COP {Maximum} [W/W] CHILLER COP {TIMESTAMP} CHILLER PART LOAD RATIO [] CHILLER PART LOAD RATIO []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 0.00 0.00
March 0.303504E+09 105034.65 30-MAR-15:00 0.83 0.217376E+10 0.00 0.247727E+10 0.01 7.25 30-MAR-15:00 0.00 0.00
April 0.343044E+10 120448.37 17-APR-15:47 9.36 0.245288E+11 0.00 0.279592E+11 0.09 7.38 14-APR-13:45 0.00 0.00
May 0.107787E+11 135247.60 31-MAY-05:03 28.94 0.755439E+11 0.00 0.863226E+11 0.27 7.76 31-MAY-05:03 0.00 0.00
June 0.463139E+11 161200.03 20-JUN-05:04 121.31 0.315263E+12 0.00 0.361577E+12 1.15 7.76 22-JUN-05:02 0.00 0.00
July 0.580351E+11 191574.98 27-JUL-05:04 151.06 0.393804E+12 0.00 0.451839E+12 1.38 7.71 24-JUL-05:03 0.00 0.00
August 0.713024E+11 177999.44 08-AUG-05:04 184.79 0.480071E+12 0.00 0.551373E+12 1.67 7.72 08-AUG-05:02 0.00 0.00
September 0.227739E+11 153711.93 07-SEP-05:02 59.84 0.155928E+12 0.00 0.178702E+12 0.57 7.75 11-SEP-05:02 0.00 0.00
October 0.503279E+10 134928.78 19-OCT-05:02 13.40 0.351052E+11 0.00 0.401380E+11 0.13 7.70 18-OCT-05:03 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 0.00 0.00
                         
Annual Sum or Average 0.217971E+12     569.54 0.148242E+13 0.00 0.170039E+13 0.44     0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00 0.00   0.00 0.00
Maximum of Months 0.713024E+11 191574.98   184.79 0.480071E+12 0.00 0.551373E+12 1.67 7.76   0.00 0.00



Table of Contents

Report: TowerReportMonthly

For: CENTRAL TOWER

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

COOLING TOWER FAN ELECTRICITY ENERGY [J] COOLING TOWER FAN ELECTRICITY ENERGY {HOURS NON-ZERO} [HOURS] COOLING TOWER FAN ELECTRICITY RATE {Maximum} [W] COOLING TOWER FAN ELECTRICITY RATE {TIMESTAMP} COOLING TOWER HEAT TRANSFER RATE {Maximum} [W] COOLING TOWER HEAT TRANSFER RATE {TIMESTAMP} COOLING TOWER INLET TEMPERATURE [C] COOLING TOWER OUTLET TEMPERATURE [C] COOLING TOWER MASS FLOW RATE [kg/s]
January 0.182366E+10 744.00 12476.23 19-JAN-14:40 29852.09 27-JAN-16:50 19.29 18.35 2.79
February 0.738653E+10 672.00 12476.23 16-FEB-13:40 60777.68 26-FEB-18:05 22.91 18.62 2.79
March 0.185342E+11 744.00 12476.23 03-MAR-12:50 106142.40 31-MAR-24:00 27.20 19.22 2.80
April 0.258269E+11 720.00 12476.23 01-APR-14:00 122650.99 17-APR-15:47 31.81 20.76 2.80
May 0.279210E+11 744.00 12476.23 01-MAY-11:10 58580.12 16-MAY-15:20 25.23 21.93 2.78
June 0.313941E+11 720.00 12476.23 01-JUN-00:10 85411.57 30-JUN-24:00 32.08 25.72 2.80
July 0.334129E+11 744.00 12476.23 01-JUL-00:10 115473.10 31-JUL-23:53 36.42 27.17 2.80
August 0.334163E+11 744.00 12476.23 01-AUG-00:05 131537.90 11-AUG-16:10 40.08 28.00 2.80
September 0.294859E+11 720.00 12476.23 01-SEP-00:10 48889.94 30-SEP-24:00 26.52 23.23 2.80
October 0.195472E+11 744.00 12476.23 01-OCT-03:50 74042.50 31-OCT-24:00 25.33 19.91 2.80
November 0.151595E+11 720.00 12476.23 01-NOV-11:50 87858.65 02-NOV-15:10 26.52 18.86 2.80
December 0.104652E+11 744.00 12476.23 05-DEC-15:00 113249.91 12-DEC-15:10 28.15 18.44 2.80
                   
Annual Sum or Average 0.254373E+12 8760.00         28.50 21.70 2.80
Minimum of Months 0.182366E+10 672.00 12476.23   29852.09   19.29 18.35 2.78
Maximum of Months 0.334163E+11 744.00 12476.23   131537.90   40.08 28.00 2.80



Table of Contents

Report: TowerReportMonthly

For: TOWERWATERSYS COOLTOWER 1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

COOLING TOWER FAN ELECTRICITY ENERGY [J] COOLING TOWER FAN ELECTRICITY ENERGY {HOURS NON-ZERO} [HOURS] COOLING TOWER FAN ELECTRICITY RATE {Maximum} [W] COOLING TOWER FAN ELECTRICITY RATE {TIMESTAMP} COOLING TOWER HEAT TRANSFER RATE {Maximum} [W] COOLING TOWER HEAT TRANSFER RATE {TIMESTAMP} COOLING TOWER INLET TEMPERATURE [C] COOLING TOWER OUTLET TEMPERATURE [C] COOLING TOWER MASS FLOW RATE [kg/s]
January 38546092.96 21.72 1075.55 19-JAN-22:00 448850.48 31-JAN-15:50 21.05 21.02 3.29
February 69472727.76 58.87 1908.42 28-FEB-14:40 977237.28 28-FEB-15:40 21.20 21.05 8.96
March 0.119070E+10 158.96 19980.60 29-MAR-13:40 1049706.55 30-MAR-14:20 21.44 21.07 19.95
April 0.352012E+10 286.42 19980.60 04-APR-08:50 1323332.21 12-APR-14:30 21.87 21.12 33.78
May 0.159063E+11 445.59 19980.60 01-MAY-13:30 1075480.80 15-MAY-13:50 22.92 21.71 42.58
June 0.295855E+11 546.23 19980.60 01-JUN-05:03 1165508.46 08-JUN-16:00 24.42 22.77 52.24
July 0.422332E+11 654.03 19980.60 01-JUL-00:43 1085968.35 27-JUL-05:04 25.33 23.59 58.61
August 0.478121E+11 692.52 19980.60 01-AUG-00:05 1038339.71 08-AUG-05:06 26.05 24.19 61.60
September 0.227998E+11 461.60 19980.60 01-SEP-04:07 1201973.67 13-SEP-15:30 23.95 22.60 44.59
October 0.680812E+10 254.32 19980.60 02-OCT-05:03 1068390.55 11-OCT-16:10 22.09 21.48 26.19
November 0.465369E+09 132.98 3800.89 27-NOV-17:00 717332.13 02-NOV-14:10 21.38 21.12 16.19
December 0.156970E+09 36.66 2803.57 13-DEC-11:00 646483.47 12-DEC-14:30 21.07 21.00 4.90
                   
Annual Sum or Average 0.170586E+12 3749.91         22.74 21.90 31.19
Minimum of Months 38546092.96 21.72 1075.55   448850.48   21.05 21.00 3.29
Maximum of Months 0.478121E+11 692.52 19980.60   1323332.21   26.05 24.19 61.60



Table of Contents

Report: TowerReportMonthly

For: TOWERWATERSYS COOLTOWER 2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

COOLING TOWER FAN ELECTRICITY ENERGY [J] COOLING TOWER FAN ELECTRICITY ENERGY {HOURS NON-ZERO} [HOURS] COOLING TOWER FAN ELECTRICITY RATE {Maximum} [W] COOLING TOWER FAN ELECTRICITY RATE {TIMESTAMP} COOLING TOWER HEAT TRANSFER RATE {Maximum} [W] COOLING TOWER HEAT TRANSFER RATE {TIMESTAMP} COOLING TOWER INLET TEMPERATURE [C] COOLING TOWER OUTLET TEMPERATURE [C] COOLING TOWER MASS FLOW RATE [kg/s]
January 0.00 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10 21.05 21.05 0.00
February 0.00 0.00 0.00 01-FEB-00:10 0.00 01-FEB-00:10 21.20 21.20 0.00
March 23976720.90 0.33 19980.60 30-MAR-13:10 1049706.55 30-MAR-14:20 21.44 21.44 0.03
April 0.233753E+09 4.14 19980.60 11-APR-15:30 1261163.74 13-APR-14:45 21.87 21.85 0.39
May 0.201105E+10 27.96 19980.60 08-MAY-10:00 1075480.80 15-MAY-13:50 22.92 22.80 2.55
June 0.105795E+11 147.08 19980.60 01-JUN-05:05 1089273.31 02-JUN-14:00 24.42 23.81 13.38
July 0.144420E+11 200.78 19980.60 01-JUL-05:02 1085968.35 27-JUL-05:04 25.33 24.54 17.17
August 0.175865E+11 244.49 19980.60 01-AUG-05:03 1022665.36 08-AUG-05:04 26.05 25.10 20.79
September 0.488034E+10 67.99 19980.60 01-SEP-05:05 1194266.72 13-SEP-15:00 23.95 23.67 6.28
October 0.118725E+10 16.51 19980.60 02-OCT-10:50 913879.89 11-OCT-12:20 22.09 22.03 1.41
November 0.00 0.00 0.00 01-NOV-00:10 0.00 01-NOV-00:10 21.38 21.38 0.00
December 0.00 0.00 0.00 01-DEC-00:10 0.00 01-DEC-00:10 21.07 21.07 0.00
                   
Annual Sum or Average 0.509444E+11 709.28         22.74 22.50 5.21
Minimum of Months 0.00 0.00 0.00   0.00   21.05 21.05 0.00
Maximum of Months 0.175865E+11 244.49 19980.60   1261163.74   26.05 25.10 20.79



Table of Contents

Report: BoilerReportMonthly

For: HEATSYS1 BOILER

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

BOILER HEATING ENERGY [J] BOILER GAS CONSUMPTION [] BOILER HEATING ENERGY {HOURS NON-ZERO} [HOURS] BOILER HEATING RATE {Maximum} [W] BOILER HEATING RATE {TIMESTAMP} BOILER GAS CONSUMPTION RATE [] BOILER INLET TEMPERATURE [C] BOILER OUTLET TEMPERATURE [C] BOILER MASS FLOW RATE [kg/s] BOILER ANCILLARY ELECTRICITY RATE [W] BOILER PART LOAD RATIO [] BOILER PART LOAD RATIO {Maximum} [] BOILER PART LOAD RATIO {TIMESTAMP}
January 0.126629E+12 0.00 440.94 1340943.21 10-JAN-06:01 0.00 31.29 60.46 0.26 0.00 0.02 0.62 10-JAN-06:01
February 0.611619E+11 0.00 303.84 1235016.66 13-FEB-06:01 0.00 26.72 49.86 0.14 0.00 0.01 0.57 13-FEB-06:01
March 0.412496E+10 0.00 104.97 354705.16 23-MAR-05:03 0.00 27.34 34.83 0.01 0.00 0.00 0.16 23-MAR-05:03
April 0.201084E+10 0.00 46.11 206070.15 06-APR-06:10 0.00 40.43 43.01 0.01 0.00 0.00 0.09 06-APR-06:10
May 0.172582E+10 0.00 27.11 102840.24 15-MAY-14:40 0.00 40.74 41.93 0.01 0.00 0.00 0.05 15-MAY-14:40
June 0.681928E+09 0.00 11.33 69212.31 02-JUN-14:20 0.00 47.32 47.94 0.00 0.00 0.00 0.03 02-JUN-14:20
July 2174.17 0.00 0.17 3.62 26-JUL-10:10 0.00 51.47 51.48 0.00 0.00 0.00 0.00 26-JUL-10:10
August 82358662.77 0.00 1.83 47293.03 25-AUG-11:30 0.00 51.34 51.41 0.00 0.00 0.00 0.02 25-AUG-11:30
September 0.269511E+09 0.00 7.57 55697.11 14-SEP-15:50 0.00 49.67 49.98 0.00 0.00 0.00 0.03 14-SEP-15:50
October 0.232347E+10 0.00 90.70 296521.76 26-OCT-05:03 0.00 33.27 39.53 0.00 0.00 0.00 0.14 26-OCT-05:03
November 0.134640E+11 0.00 180.62 959573.26 21-NOV-06:01 0.00 24.94 38.10 0.03 0.00 0.00 0.44 21-NOV-06:01
December 0.501585E+11 0.00 349.69 1061633.25 26-DEC-05:01 0.00 25.40 50.23 0.09 0.00 0.01 0.49 26-DEC-05:01
                           
Annual Sum or Average 0.262633E+12 0.00 1564.89     0.00 37.55 46.56 0.04 0.00 0.00    
Minimum of Months 2174.17 0.00 0.17 3.62   0.00 24.94 34.83 0.00 0.00 0.00 0.00  
Maximum of Months 0.126629E+12 0.00 440.94 1340943.21   0.00 51.47 60.46 0.26 0.00 0.02 0.62  



Table of Contents

Report: BoilerReportMonthly

For: CENTRAL BOILER

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

BOILER HEATING ENERGY [J] BOILER GAS CONSUMPTION [] BOILER HEATING ENERGY {HOURS NON-ZERO} [HOURS] BOILER HEATING RATE {Maximum} [W] BOILER HEATING RATE {TIMESTAMP} BOILER GAS CONSUMPTION RATE [] BOILER INLET TEMPERATURE [C] BOILER OUTLET TEMPERATURE [C] BOILER MASS FLOW RATE [kg/s] BOILER ANCILLARY ELECTRICITY RATE [W] BOILER PART LOAD RATIO [] BOILER PART LOAD RATIO []
January 0.00 0.00 0.00 0.00 01-JAN-00:10 0.00 19.29 19.29 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 01-FEB-00:10 0.00 22.91 22.91 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 01-MAR-00:10 0.00 27.20 27.20 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 01-APR-00:10 0.00 31.81 31.81 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 01-MAY-00:03 0.00 25.23 25.23 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 01-JUN-00:10 0.00 32.08 32.08 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 01-JUL-00:10 0.00 36.42 36.42 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 01-AUG-00:05 0.00 40.08 40.08 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 01-SEP-00:10 0.00 26.52 26.52 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 01-OCT-00:10 0.00 25.33 25.33 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 01-NOV-00:10 0.00 26.52 26.52 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 01-DEC-00:10 0.00 28.15 28.15 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.00 0.00 0.00     0.00 28.50 28.50 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00   0.00 19.29 19.29 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00   0.00 40.08 40.08 0.00 0.00 0.00 0.00



Table of Contents

Report: DXReportMonthly

For: VAV_BOT WITH REHEAT COOLING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION [] COOLING COIL RUNTIME FRACTION [] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE [] COOLING COIL ELECTRICITY RATE [] COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.155745E+10 0.00 65.11 0.148014E+10 0.00 0.00 0.00 0.00 34511.59 31-JAN-15:00 34511.59 31-JAN-15:00 0.00 0.00 0.00
February 0.744007E+10 0.00 110.58 0.743343E+10 0.00 0.00 0.00 0.00 81310.94 28-FEB-15:00 81310.94 28-FEB-15:00 0.00 0.00 0.00
March 0.238177E+11 0.00 251.24 0.229906E+11 0.00 0.00 0.00 0.00 111096.78 30-MAR-15:20 111096.78 30-MAR-15:20 0.00 0.00 0.00
April 0.525315E+11 0.00 390.63 0.501302E+11 0.00 0.00 0.00 0.00 145242.79 17-APR-14:15 145242.79 17-APR-14:15 0.00 0.00 0.00
May 0.823595E+11 0.00 455.71 0.706935E+11 0.00 0.00 0.00 0.00 201384.27 19-MAY-14:07 189661.86 19-MAY-14:07 0.00 0.00 0.00
June 0.127376E+12 0.00 544.47 0.110059E+12 0.00 0.00 0.00 0.00 199716.30 26-JUN-05:02 140792.35 26-JUN-05:02 0.00 0.00 0.00
July 0.152814E+12 0.00 620.16 0.127561E+12 0.00 0.00 0.00 0.00 199463.71 06-JUL-05:03 143386.41 17-JUL-05:02 0.00 0.00 0.00
August 0.174329E+12 0.00 658.47 0.145017E+12 0.00 0.00 0.00 0.00 201716.85 10-AUG-05:03 145288.87 14-AUG-05:03 0.00 0.00 0.00
September 0.960391E+11 0.00 454.73 0.805194E+11 0.00 0.00 0.00 0.00 200171.35 27-SEP-05:03 140446.47 11-SEP-03:02 0.00 0.00 0.00
October 0.449671E+11 0.00 283.04 0.376853E+11 0.00 0.00 0.00 0.00 199546.82 19-OCT-05:02 134566.80 19-OCT-05:02 0.00 0.00 0.00
November 0.165685E+11 0.00 180.42 0.153046E+11 0.00 0.00 0.00 0.00 105029.68 27-NOV-06:02 105029.68 27-NOV-06:02 0.00 0.00 0.00
December 0.500693E+10 0.00 61.46 0.419463E+10 0.00 0.00 0.00 0.00 92243.74 13-DEC-06:02 66470.34 12-DEC-14:30 0.00 0.00 0.00
                               
Annual Sum or Average 0.784806E+12 0.00 4076.02 0.673069E+12 0.00 0.00 0.00 0.00         0.00 0.00 0.00
Minimum of Months 0.155745E+10 0.00 61.46 0.148014E+10 0.00 0.00 0.00 0.00 34511.59   34511.59   0.00 0.00 0.00
Maximum of Months 0.174329E+12 0.00 658.47 0.145017E+12 0.00 0.00 0.00 0.00 201716.85   189661.86   0.00 0.00 0.00



Table of Contents

Report: DXReportMonthly

For: VAV_MID WITH REHEAT COOLING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION [] COOLING COIL RUNTIME FRACTION [] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE [] COOLING COIL ELECTRICITY RATE [] COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.110100E+11 0.00 51.12 0.104593E+11 0.00 0.00 0.00 0.00 212809.01 31-JAN-15:00 212809.01 31-JAN-15:00 0.00 0.00 0.00
February 0.537523E+11 0.00 97.00 0.537523E+11 0.00 0.00 0.00 0.00 612224.96 28-FEB-15:00 612224.96 28-FEB-15:00 0.00 0.00 0.00
March 0.170511E+12 0.00 228.01 0.165781E+12 0.00 0.00 0.00 0.00 985515.94 30-MAR-15:20 985515.94 30-MAR-15:20 0.00 0.00 0.00
April 0.368030E+12 0.00 306.69 0.353681E+12 0.00 0.00 0.00 0.00 1212118.64 17-APR-15:47 1212118.64 17-APR-15:47 0.00 0.00 0.00
May 0.709177E+12 0.00 432.94 0.608298E+12 0.00 0.00 0.00 0.00 1865222.04 31-MAY-05:03 1346888.27 19-MAY-13:20 0.00 0.00 0.00
June 0.105066E+13 0.00 468.58 0.881341E+12 0.00 0.00 0.00 0.00 1879977.23 24-JUN-05:02 1279424.89 29-JUN-05:02 0.00 0.00 0.00
July 0.117963E+13 0.00 496.49 0.936349E+12 0.00 0.00 0.00 0.00 1921395.48 27-JUL-05:02 1308247.08 15-JUL-05:03 0.00 0.00 0.00
August 0.131391E+13 0.00 519.09 0.102876E+13 0.00 0.00 0.00 0.00 1929683.50 05-AUG-05:03 1314492.63 10-AUG-05:03 0.00 0.00 0.00
September 0.800945E+12 0.00 421.28 0.655171E+12 0.00 0.00 0.00 0.00 1910219.85 27-SEP-05:03 1278445.20 27-SEP-05:03 0.00 0.00 0.00
October 0.336012E+12 0.00 259.85 0.273714E+12 0.00 0.00 0.00 0.00 1952997.21 19-OCT-05:02 1213663.77 19-OCT-05:02 0.00 0.00 0.00
November 0.104791E+12 0.00 162.83 0.989651E+11 0.00 0.00 0.00 0.00 614706.35 04-NOV-05:03 449461.62 02-NOV-14:10 0.00 0.00 0.00
December 0.267407E+11 0.00 57.99 0.230094E+11 0.00 0.00 0.00 0.00 659859.82 13-DEC-06:02 391929.10 12-DEC-14:10 0.00 0.00 0.00
                               
Annual Sum or Average 0.612517E+13 0.00 3501.87 0.508928E+13 0.00 0.00 0.00 0.00         0.00 0.00 0.00
Minimum of Months 0.110100E+11 0.00 51.12 0.104593E+11 0.00 0.00 0.00 0.00 212809.01   212809.01   0.00 0.00 0.00
Maximum of Months 0.131391E+13 0.00 519.09 0.102876E+13 0.00 0.00 0.00 0.00 1952997.21   1346888.27   0.00 0.00 0.00



Table of Contents

Report: DXReportMonthly

For: VAV_TOP WITH REHEAT COOLING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION [] COOLING COIL RUNTIME FRACTION [] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE [] COOLING COIL ELECTRICITY RATE [] COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.108223E+10 0.00 52.89 0.102578E+10 0.00 0.00 0.00 0.00 19832.13 31-JAN-15:00 19832.13 31-JAN-15:00 0.00 0.00 0.00
February 0.457326E+10 0.00 98.06 0.457326E+10 0.00 0.00 0.00 0.00 55955.64 28-FEB-15:00 55955.64 28-FEB-15:00 0.00 0.00 0.00
March 0.162257E+11 0.00 221.51 0.158725E+11 0.00 0.00 0.00 0.00 110203.12 30-MAR-15:40 110203.12 30-MAR-15:40 0.00 0.00 0.00
April 0.379464E+11 0.00 301.17 0.364837E+11 0.00 0.00 0.00 0.00 142488.44 17-APR-15:40 142488.44 17-APR-15:40 0.00 0.00 0.00
May 0.778574E+11 0.00 429.57 0.675624E+11 0.00 0.00 0.00 0.00 189327.60 31-MAY-05:03 156751.91 19-MAY-13:40 0.00 0.00 0.00
June 0.118888E+12 0.00 473.73 0.101316E+12 0.00 0.00 0.00 0.00 196117.40 26-JUN-05:02 135729.67 26-JUN-05:02 0.00 0.00 0.00
July 0.133940E+12 0.00 510.76 0.109011E+12 0.00 0.00 0.00 0.00 200608.40 27-JUL-05:02 136782.11 15-JUL-05:03 0.00 0.00 0.00
August 0.147295E+12 0.00 532.53 0.118235E+12 0.00 0.00 0.00 0.00 206814.05 23-AUG-03:02 150568.34 25-AUG-14:00 0.00 0.00 0.00
September 0.835004E+11 0.00 418.98 0.692100E+11 0.00 0.00 0.00 0.00 198829.93 27-SEP-05:03 132854.85 27-SEP-05:03 0.00 0.00 0.00
October 0.325709E+11 0.00 251.69 0.263161E+11 0.00 0.00 0.00 0.00 189472.39 19-OCT-05:02 114821.85 19-OCT-05:02 0.00 0.00 0.00
November 0.866288E+10 0.00 163.99 0.815712E+10 0.00 0.00 0.00 0.00 41801.82 02-NOV-14:30 41801.82 02-NOV-14:30 0.00 0.00 0.00
December 0.229870E+10 0.00 64.42 0.197643E+10 0.00 0.00 0.00 0.00 31217.48 12-DEC-14:00 31217.48 12-DEC-14:00 0.00 0.00 0.00
                               
Annual Sum or Average 0.664841E+12 0.00 3519.28 0.559740E+12 0.00 0.00 0.00 0.00         0.00 0.00 0.00
Minimum of Months 0.108223E+10 0.00 52.89 0.102578E+10 0.00 0.00 0.00 0.00 19832.13   19832.13   0.00 0.00 0.00
Maximum of Months 0.147295E+12 0.00 532.53 0.118235E+12 0.00 0.00 0.00 0.00 206814.05   156751.91   0.00 0.00 0.00



Table of Contents

Report: DXReportMonthly

For: CAV_BAS COOLING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION [] COOLING COIL RUNTIME FRACTION [] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE [] COOLING COIL ELECTRICITY RATE [] COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.515848E+09 0.00 18.63 0.505796E+09 0.00 0.00 0.00 0.00 48413.56 19-JAN-06:03 26111.06 31-JAN-15:00 0.00 0.00 0.00
February 0.371315E+10 0.00 45.64 0.369812E+10 0.00 0.00 0.00 0.00 52205.37 28-FEB-14:10 52205.37 28-FEB-14:10 0.00 0.00 0.00
March 0.111314E+11 0.00 143.24 0.110818E+11 0.00 0.00 0.00 0.00 74611.02 29-MAR-04:12 66173.05 30-MAR-14:20 0.00 0.00 0.00
April 0.236136E+11 0.00 214.36 0.231914E+11 0.00 0.00 0.00 0.00 81252.03 03-APR-03:03 81252.03 03-APR-03:03 0.00 0.00 0.00
May 0.432706E+11 0.00 335.13 0.390764E+11 0.00 0.00 0.00 0.00 114911.65 31-MAY-03:02 78648.32 19-MAY-13:00 0.00 0.00 0.00
June 0.751714E+11 0.00 390.52 0.624147E+11 0.00 0.00 0.00 0.00 137095.96 26-JUN-03:02 93684.63 12-JUN-03:02 0.00 0.00 0.00
July 0.870862E+11 0.00 402.77 0.681352E+11 0.00 0.00 0.00 0.00 140854.16 07-JUL-03:02 83622.44 05-JUL-03:02 0.00 0.00 0.00
August 0.104170E+12 0.00 459.89 0.800542E+11 0.00 0.00 0.00 0.00 144952.15 04-AUG-03:02 85311.47 13-AUG-20:30 0.00 0.00 0.00
September 0.654298E+11 0.00 367.98 0.546189E+11 0.00 0.00 0.00 0.00 135147.04 04-SEP-10:40 84052.13 05-SEP-03:13 0.00 0.00 0.00
October 0.294703E+11 0.00 220.61 0.246184E+11 0.00 0.00 0.00 0.00 133346.69 19-OCT-03:02 86273.56 09-OCT-14:12 0.00 0.00 0.00
November 0.974296E+10 0.00 118.14 0.889942E+10 0.00 0.00 0.00 0.00 72417.65 27-NOV-06:02 68341.18 20-NOV-01:53 0.00 0.00 0.00
December 0.284879E+10 0.00 38.88 0.258534E+10 0.00 0.00 0.00 0.00 69467.61 13-DEC-06:02 43946.68 12-DEC-14:10 0.00 0.00 0.00
                               
Annual Sum or Average 0.456164E+12 0.00 2755.80 0.378880E+12 0.00 0.00 0.00 0.00         0.00 0.00 0.00
Minimum of Months 0.515848E+09 0.00 18.63 0.505796E+09 0.00 0.00 0.00 0.00 48413.56   26111.06   0.00 0.00 0.00
Maximum of Months 0.104170E+12 0.00 459.89 0.800542E+11 0.00 0.00 0.00 0.00 144952.15   93684.63   0.00 0.00 0.00



Table of Contents

Report: DXReportMonthly

For: AIRLOOP DATACENTER BOT COOLING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.373338E+10 0.923067E+09 744.00 0.371512E+10 18257602.06 0.00 0.29 15-JAN-17:40 0.06 09-JAN-07:10 2162.98 22-JAN-17:40 2162.98 22-JAN-17:40 216.72 19-JAN-17:00 518.86 15-JAN-17:40 0.00
February 0.861959E+10 0.196724E+10 672.00 0.859988E+10 19717453.00 0.00 0.58 26-FEB-17:35 0.34 13-FEB-07:10 4463.74 20-FEB-17:45 4440.12 20-FEB-17:50 217.31 17-FEB-17:00 1195.41 26-FEB-17:23 0.00
March 0.154884E+11 0.335711E+10 744.00 0.154245E+11 63897314.92 0.00 0.86 31-MAR-24:00 0.61 22-MAR-07:00 7680.19 31-MAR-24:00 7680.19 31-MAR-24:00 302.01 31-MAR-11:30 1735.20 30-MAR-16:00 0.00
April 0.200925E+11 0.434530E+10 720.00 0.199983E+11 94163894.72 0.00 0.97 08-APR-18:10 0.30 30-APR-24:00 8385.16 09-APR-18:23 8385.16 09-APR-18:23 343.04 04-APR-10:00 2270.86 16-APR-14:00 0.00
May 0.592302E+10 0.149833E+10 744.00 0.570568E+10 0.217338E+09 0.00 0.49 31-MAY-23:30 0.21 11-MAY-06:10 4044.62 31-MAY-23:20 3989.30 31-MAY-24:00 330.17 31-MAY-13:50 962.89 31-MAY-23:20 0.00
June 0.109921E+11 0.293676E+10 720.00 0.106324E+11 0.359678E+09 0.00 0.69 30-JUN-24:00 0.44 10-JUN-06:50 5877.30 30-JUN-24:00 5860.47 30-JUN-24:00 481.85 26-JUN-16:20 1558.97 06-JUN-15:00 0.00
July 0.165690E+11 0.440686E+10 744.00 0.160958E+11 0.473208E+09 0.00 0.90 31-JUL-23:43 0.66 29-JUL-06:10 7790.18 31-JUL-23:53 7763.75 31-JUL-23:57 550.04 26-JUL-10:40 2244.03 07-JUL-16:00 0.00
August 0.217033E+11 0.568377E+10 744.00 0.211361E+11 0.567207E+09 0.00 1.00 01-AUG-12:20 0.31 31-AUG-24:00 8621.54 21-AUG-15:50 8388.79 13-AUG-18:40 593.64 11-AUG-17:00 2678.59 01-AUG-16:10 0.00
September 0.592792E+10 0.154818E+10 720.00 0.563021E+10 0.297717E+09 0.00 0.45 30-SEP-24:00 0.21 29-SEP-07:00 3778.05 30-SEP-24:00 3775.45 30-SEP-24:00 408.30 05-SEP-11:00 919.96 07-SEP-16:00 0.00
October 0.106771E+11 0.241900E+10 744.00 0.105328E+11 0.144323E+09 0.00 0.68 31-OCT-24:00 0.41 26-OCT-07:00 5686.49 31-OCT-24:00 5686.49 31-OCT-24:00 499.42 18-OCT-16:00 1380.68 10-OCT-16:00 0.00
November 0.149045E+11 0.321030E+10 720.00 0.148509E+11 53576087.52 0.00 0.78 19-NOV-17:00 0.61 30-NOV-22:00 6351.18 11-NOV-16:55 6351.18 11-NOV-16:55 282.23 27-NOV-17:10 1633.47 19-NOV-15:03 0.00
December 0.201190E+11 0.417009E+10 744.00 0.200865E+11 32523048.05 0.00 0.97 10-DEC-16:33 0.78 01-DEC-07:10 8092.36 10-DEC-17:00 8092.36 10-DEC-17:00 337.66 13-DEC-16:00 1878.43 12-DEC-14:50 0.00
                                       
Annual Sum or Average 0.154750E+12 0.364660E+11 8760.00 0.152408E+12 0.234161E+10 0.00                         0.00
Minimum of Months 0.373338E+10 0.923067E+09 672.00 0.371512E+10 18257602.06 0.00 0.29   0.06   2162.98   2162.98   216.72   518.86   0.00
Maximum of Months 0.217033E+11 0.568377E+10 744.00 0.211361E+11 0.567207E+09 0.00 1.00   0.78   8621.54   8388.79   593.64   2678.59   0.00



Table of Contents

Report: DXReportMonthly

For: AIRLOOP DATACENTER MID COOLING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.135072E+11 0.360514E+10 651.67 0.133462E+11 0.161006E+09 0.00 0.23 20-JAN-17:00 0.00 02-JAN-03:35 17428.35 20-JAN-17:00 16479.75 20-JAN-17:00 2010.66 19-JAN-17:00 4417.82 27-JAN-16:40 0.00
February 0.660915E+11 0.153912E+11 672.00 0.658973E+11 0.194154E+09 0.00 0.54 26-FEB-17:43 0.19 13-FEB-07:10 39326.17 28-FEB-17:00 39326.17 28-FEB-17:00 2134.20 17-FEB-17:00 10484.73 28-FEB-15:00 0.00
March 0.140079E+12 0.305754E+11 744.00 0.139438E+12 0.641256E+09 0.00 0.85 31-MAR-24:00 0.55 23-MAR-07:00 72251.17 31-MAR-24:00 72251.17 31-MAR-24:00 2996.51 31-MAR-11:30 16729.25 30-MAR-14:20 0.00
April 0.188899E+12 0.409543E+11 720.00 0.187954E+12 0.944991E+09 0.00 0.96 17-APR-16:00 0.27 30-APR-24:00 78131.02 04-APR-15:30 78076.94 09-APR-18:27 3434.01 04-APR-10:00 21648.23 17-APR-16:00 0.00
May 0.538918E+11 0.137435E+11 744.00 0.517531E+11 0.213871E+10 0.00 0.49 31-MAY-23:20 0.18 11-MAY-06:30 38329.03 31-MAY-23:20 37717.99 31-MAY-24:00 3280.11 31-MAY-13:50 9125.39 31-MAY-23:20 0.00
June 0.104026E+12 0.278300E+11 720.00 0.100443E+12 0.358276E+10 0.00 0.70 30-JUN-24:00 0.42 10-JUN-06:50 56309.72 30-JUN-24:00 56134.12 30-JUN-24:00 4786.26 26-JUN-16:20 14888.53 06-JUN-15:00 0.00
July 0.157724E+12 0.419568E+11 744.00 0.153000E+12 0.472324E+10 0.00 0.91 31-JUL-23:53 0.64 29-JUL-06:10 75147.16 31-JUL-23:53 74887.55 31-JUL-23:57 5502.09 26-JUL-10:40 21467.95 07-JUL-16:00 0.00
August 0.207235E+12 0.542374E+11 744.00 0.201567E+12 0.566831E+10 0.00 1.00 01-AUG-11:00 0.27 31-AUG-24:00 82371.93 04-AUG-14:40 79030.05 13-AUG-18:40 5954.67 11-AUG-17:00 25521.49 01-AUG-16:10 0.00
September 0.533788E+11 0.140291E+11 720.00 0.504487E+11 0.293017E+10 0.00 0.42 30-SEP-24:00 0.18 29-SEP-07:00 32889.84 30-SEP-24:00 32795.31 30-SEP-24:00 4044.81 06-SEP-14:30 8749.90 07-SEP-16:00 0.00
October 0.939982E+11 0.214946E+11 744.00 0.925652E+11 0.143297E+10 0.00 0.63 31-OCT-24:00 0.33 31-OCT-07:00 49870.54 31-OCT-24:00 49870.54 31-OCT-24:00 4968.97 18-OCT-16:00 13049.91 10-OCT-16:00 0.00
November 0.130176E+12 0.283394E+11 720.00 0.129641E+12 0.535463E+09 0.00 0.74 19-NOV-17:03 0.53 22-NOV-07:10 57785.84 03-NOV-15:20 57456.86 06-NOV-17:00 2797.35 27-NOV-17:00 14577.23 19-NOV-16:45 0.00
December 0.171720E+12 0.361342E+11 744.00 0.171392E+12 0.327090E+09 0.00 0.90 19-DEC-17:00 0.67 26-DEC-07:30 75448.36 13-DEC-16:00 73249.32 11-DEC-17:00 3363.86 13-DEC-16:00 17595.65 12-DEC-15:00 0.00
                                       
Annual Sum or Average 0.138073E+13 0.328291E+12 8667.67 0.135745E+13 0.232801E+11 0.00                         0.00
Minimum of Months 0.135072E+11 0.360514E+10 651.67 0.133462E+11 0.161006E+09 0.00 0.23   0.00   17428.35   16479.75   2010.66   4417.82   0.00
Maximum of Months 0.207235E+12 0.542374E+11 744.00 0.201567E+12 0.566831E+10 0.00 1.00   0.67   82371.93   79030.05   5954.67   25521.49   0.00



Table of Contents

Report: DXReportMonthly

For: AIRLOOP DATACENTER TOP COOLING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.437924E+09 0.116290E+09 245.42 0.423553E+09 14371032.66 0.00 0.23 20-JAN-17:00 0.00 01-JAN-00:10 1746.90 20-JAN-17:00 1647.75 20-JAN-17:00 206.45 19-JAN-16:30 395.79 20-JAN-17:00 0.00
February 0.521747E+10 0.123207E+10 666.38 0.519844E+10 19035872.77 0.00 0.52 27-FEB-17:00 0.00 05-FEB-05:55 3955.90 28-FEB-17:00 3955.90 28-FEB-17:00 211.74 17-FEB-17:00 1047.03 28-FEB-17:00 0.00
March 0.131447E+11 0.289482E+10 744.00 0.130810E+11 63737066.86 0.00 0.82 31-MAR-23:30 0.44 23-MAR-06:10 6998.05 31-MAR-23:30 6998.05 31-MAR-23:30 299.89 31-MAR-11:30 1679.76 30-MAR-16:00 0.00
April 0.185126E+11 0.403642E+10 720.00 0.184184E+11 94186420.19 0.00 0.95 17-APR-16:00 0.25 30-APR-24:00 7867.29 09-APR-18:18 7867.29 09-APR-18:16 343.66 04-APR-10:00 2189.88 17-APR-16:00 0.00
May 0.534649E+10 0.136699E+10 744.00 0.513196E+10 0.214534E+09 0.00 0.48 31-MAY-23:20 0.12 11-MAY-07:00 3813.05 31-MAY-23:20 3746.16 31-MAY-24:00 332.52 31-MAY-13:40 909.52 31-MAY-23:20 0.00
June 0.104965E+11 0.281265E+10 720.00 0.101380E+11 0.358538E+09 0.00 0.69 30-JUN-24:00 0.39 08-JUN-06:50 5623.15 30-JUN-24:00 5605.34 30-JUN-24:00 480.22 26-JUN-16:20 1520.13 06-JUN-15:00 0.00
July 0.158919E+11 0.423508E+10 744.00 0.154198E+11 0.472161E+09 0.00 0.91 31-JUL-23:53 0.62 29-JUL-07:00 7563.56 31-JUL-23:53 7537.45 31-JUL-23:57 551.04 26-JUL-10:40 2184.80 07-JUL-16:00 0.00
August 0.208474E+11 0.546546E+10 744.00 0.202808E+11 0.566617E+09 0.00 1.00 01-AUG-12:10 0.26 31-AUG-24:00 8321.39 04-AUG-14:30 8167.57 13-AUG-19:04 591.52 11-AUG-17:00 2589.37 01-AUG-16:10 0.00
September 0.522606E+10 0.138260E+10 720.00 0.493398E+10 0.292073E+09 0.00 0.38 07-SEP-16:00 0.11 29-SEP-07:00 2846.69 30-SEP-23:30 2818.77 30-SEP-24:00 408.86 06-SEP-14:30 902.91 07-SEP-16:00 0.00
October 0.861980E+10 0.199391E+10 744.00 0.847739E+10 0.142417E+09 0.00 0.57 10-OCT-16:00 0.23 30-OCT-06:10 4465.59 31-OCT-23:30 4465.59 31-OCT-23:30 497.48 18-OCT-16:00 1324.88 10-OCT-16:00 0.00
November 0.116459E+11 0.256814E+10 720.00 0.115929E+11 53012791.77 0.00 0.72 08-NOV-17:00 0.40 22-NOV-07:10 5793.91 02-NOV-16:00 5731.30 06-NOV-17:00 278.52 27-NOV-17:00 1403.78 02-NOV-14:00 0.00
December 0.152446E+11 0.325890E+10 744.00 0.152122E+11 32445055.71 0.00 0.87 12-DEC-15:30 0.51 18-DEC-04:17 7507.77 13-DEC-16:00 7233.66 12-DEC-17:00 335.91 13-DEC-16:00 1742.33 12-DEC-15:00 0.00
                                       
Annual Sum or Average 0.130631E+12 0.313633E+11 8255.80 0.128308E+12 0.232313E+10 0.00                         0.00
Minimum of Months 0.437924E+09 0.116290E+09 245.42 0.423553E+09 14371032.66 0.00 0.23   0.00   1746.90   1647.75   206.45   395.79   0.00
Maximum of Months 0.208474E+11 0.546546E+10 744.00 0.202808E+11 0.566617E+09 0.00 1.00   0.62   8321.39   8167.57   591.52   2589.37   0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 74.22 0.00 74.22 7.46 548.16 0.00 0.00 0.00
February 82.27 0.00 82.27 29.04 453.61 0.00 0.00 0.00
March 115.50 0.00 115.50 72.25 286.50 0.00 0.00 0.00
April 139.70 0.62 139.08 149.17 216.51 0.00 0.00 0.00
May 167.08 5.33 161.75 234.49 134.75 0.00 0.00 0.00
June 183.88 12.14 171.74 334.87 81.55 0.00 0.00 0.00
July 173.49 8.43 165.06 333.93 57.76 0.00 0.00 0.00
August 154.29 1.68 152.61 303.90 47.77 0.00 0.00 0.00
September 116.63 0.02 116.62 173.94 116.98 0.00 0.00 0.00
October 88.68 0.00 88.68 73.04 261.25 0.00 0.00 0.00
November 79.36 0.00 79.36 32.23 364.82 0.00 0.00 0.00
December 68.61 0.00 68.61 6.55 477.10 0.00 0.00 0.00
                 
Annual Sum or Average 120.52 2.36 118.16 146.58 252.90 0.00 0.00 0.00
Minimum of Months 68.61 0.00 68.61 6.55 47.77 0.00 0.00 0.00
Maximum of Months 183.88 12.14 171.74 334.87 548.16 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 74.22 0.00 74.22 7.46 548.16 0.00 0.00 0.00
February 82.26 0.00 82.26 29.04 453.61 0.00 0.00 0.00
March 115.49 0.00 115.49 72.25 286.50 0.00 0.00 0.00
April 139.70 0.62 139.08 149.17 216.51 0.00 0.00 0.00
May 167.08 5.33 161.75 234.49 134.75 0.00 0.00 0.00
June 183.88 12.14 171.74 334.87 81.55 0.00 0.00 0.00
July 173.49 8.43 165.06 333.92 57.76 0.00 0.00 0.00
August 154.29 1.68 152.61 303.90 47.77 0.00 0.00 0.00
September 116.63 0.02 116.61 173.94 116.98 0.00 0.00 0.00
October 88.68 0.00 88.68 73.04 261.25 0.00 0.00 0.00
November 79.36 0.00 79.36 32.23 364.82 0.00 0.00 0.00
December 68.61 0.00 68.61 6.55 477.10 0.00 0.00 0.00
                 
Annual Sum or Average 120.52 2.36 118.15 146.57 252.90 0.00 0.00 0.00
Minimum of Months 68.61 0.00 68.61 6.55 47.77 0.00 0.00 0.00
Maximum of Months 183.88 12.14 171.74 334.87 548.16 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 74.22 0.00 74.22 7.46 548.16 0.00 0.00 0.00
February 82.26 0.00 82.26 29.04 453.61 0.00 0.00 0.00
March 115.50 0.00 115.50 72.25 286.50 0.00 0.00 0.00
April 139.70 0.62 139.08 149.17 216.51 0.00 0.00 0.00
May 167.08 5.33 161.75 234.49 134.75 0.00 0.00 0.00
June 183.88 12.14 171.74 334.87 81.55 0.00 0.00 0.00
July 173.49 8.43 165.06 333.92 57.76 0.00 0.00 0.00
August 154.29 1.68 152.61 303.90 47.77 0.00 0.00 0.00
September 116.63 0.02 116.61 173.94 116.98 0.00 0.00 0.00
October 88.68 0.00 88.68 73.04 261.25 0.00 0.00 0.00
November 79.36 0.00 79.36 32.23 364.82 0.00 0.00 0.00
December 68.61 0.00 68.61 6.55 477.10 0.00 0.00 0.00
                 
Annual Sum or Average 120.52 2.36 118.15 146.57 252.90 0.00 0.00 0.00
Minimum of Months 68.61 0.00 68.61 6.55 47.77 0.00 0.00 0.00
Maximum of Months 183.88 12.14 171.74 334.87 548.16 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 74.22 0.00 74.22 7.46 548.16 0.00 0.00 0.00
February 82.26 0.00 82.26 29.04 453.61 0.00 0.00 0.00
March 115.49 0.00 115.49 72.25 286.50 0.00 0.00 0.00
April 139.70 0.62 139.08 149.17 216.51 0.00 0.00 0.00
May 167.08 5.33 161.75 234.49 134.75 0.00 0.00 0.00
June 183.88 12.14 171.74 334.87 81.55 0.00 0.00 0.00
July 173.49 8.43 165.06 333.92 57.76 0.00 0.00 0.00
August 154.29 1.68 152.61 303.90 47.77 0.00 0.00 0.00
September 116.63 0.02 116.61 173.94 116.98 0.00 0.00 0.00
October 88.68 0.00 88.68 73.04 261.25 0.00 0.00 0.00
November 79.36 0.00 79.36 32.23 364.82 0.00 0.00 0.00
December 68.61 0.00 68.61 6.55 477.10 0.00 0.00 0.00
                 
Annual Sum or Average 120.52 2.36 118.15 146.57 252.90 0.00 0.00 0.00
Minimum of Months 68.61 0.00 68.61 6.55 47.77 0.00 0.00 0.00
Maximum of Months 183.88 12.14 171.74 334.87 548.16 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 74.22 0.00 74.22 7.46 548.14 0.00 0.00 0.00
February 82.26 0.00 82.26 29.04 453.59 0.00 0.00 0.00
March 115.49 0.00 115.49 72.24 286.49 0.00 0.00 0.00
April 139.70 0.62 139.08 149.16 216.50 0.00 0.00 0.00
May 167.07 5.33 161.74 234.48 134.75 0.00 0.00 0.00
June 183.87 12.14 171.73 334.85 81.55 0.00 0.00 0.00
July 173.48 8.43 165.05 333.91 57.76 0.00 0.00 0.00
August 154.29 1.68 152.61 303.89 47.76 0.00 0.00 0.00
September 116.63 0.02 116.61 173.93 116.98 0.00 0.00 0.00
October 88.67 0.00 88.67 73.04 261.24 0.00 0.00 0.00
November 79.36 0.00 79.36 32.22 364.81 0.00 0.00 0.00
December 68.61 0.00 68.61 6.55 477.08 0.00 0.00 0.00
                 
Annual Sum or Average 120.51 2.36 118.15 146.57 252.89 0.00 0.00 0.00
Minimum of Months 68.61 0.00 68.61 6.55 47.76 0.00 0.00 0.00
Maximum of Months 183.87 12.14 171.73 334.85 548.14 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 181.11 81.69 99.42 119.36 544.26 0.00 0.00 0.00
February 228.32 122.67 105.65 214.57 448.19 0.00 0.00 0.00
March 287.25 130.77 156.49 322.86 284.58 0.00 0.00 0.00
April 347.36 158.39 188.97 481.49 218.62 0.00 0.00 0.00
May 381.43 161.30 220.13 588.74 147.14 0.00 0.00 0.00
June 394.91 165.52 229.39 694.50 88.62 0.00 0.00 0.00
July 385.05 161.88 223.17 699.90 60.99 0.00 0.00 0.00
August 352.20 139.73 212.47 651.76 48.21 0.00 0.00 0.00
September 289.46 128.25 161.21 463.72 124.12 0.00 0.00 0.00
October 246.93 128.48 118.45 314.62 263.55 0.00 0.00 0.00
November 197.42 89.39 108.03 186.17 355.55 0.00 0.00 0.00
December 171.01 77.95 93.06 119.69 459.79 0.00 0.00 0.00
                 
Annual Sum or Average 288.83 128.81 160.01 405.78 252.66 0.00 0.00 0.00
Minimum of Months 171.01 77.95 93.06 119.36 48.21 0.00 0.00 0.00
Maximum of Months 394.91 165.52 229.39 699.90 544.26 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 181.11 81.69 99.42 119.36 544.26 0.00 0.00 0.00
February 228.32 122.67 105.65 214.57 448.19 0.00 0.00 0.00
March 287.25 130.77 156.49 322.86 284.58 0.00 0.00 0.00
April 347.36 158.39 188.97 481.49 218.62 0.00 0.00 0.00
May 381.43 161.30 220.13 588.74 147.14 0.00 0.00 0.00
June 394.91 165.52 229.39 694.50 88.62 0.00 0.00 0.00
July 385.05 161.88 223.17 699.90 60.99 0.00 0.00 0.00
August 352.20 139.73 212.47 651.76 48.21 0.00 0.00 0.00
September 289.46 128.25 161.21 463.72 124.12 0.00 0.00 0.00
October 246.93 128.48 118.45 314.62 263.55 0.00 0.00 0.00
November 197.42 89.39 108.03 186.17 355.55 0.00 0.00 0.00
December 171.01 77.95 93.06 119.69 459.79 0.00 0.00 0.00
                 
Annual Sum or Average 288.83 128.81 160.01 405.78 252.66 0.00 0.00 0.00
Minimum of Months 171.01 77.95 93.06 119.36 48.21 0.00 0.00 0.00
Maximum of Months 394.91 165.52 229.39 699.90 544.26 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 181.10 81.69 99.42 119.36 544.25 0.00 0.00 0.00
February 228.32 122.67 105.64 214.57 448.18 0.00 0.00 0.00
March 287.25 130.76 156.48 322.85 284.58 0.00 0.00 0.00
April 347.36 158.39 188.97 481.48 218.62 0.00 0.00 0.00
May 381.42 161.30 220.12 588.73 147.14 0.00 0.00 0.00
June 394.90 165.51 229.39 694.48 88.62 0.00 0.00 0.00
July 385.04 161.88 223.17 699.88 60.99 0.00 0.00 0.00
August 352.19 139.73 212.46 651.74 48.21 0.00 0.00 0.00
September 289.45 128.25 161.20 463.71 124.12 0.00 0.00 0.00
October 246.93 128.48 118.44 314.62 263.55 0.00 0.00 0.00
November 197.42 89.39 108.03 186.17 355.54 0.00 0.00 0.00
December 171.00 77.95 93.05 119.69 459.78 0.00 0.00 0.00
                 
Annual Sum or Average 288.82 128.81 160.01 405.77 252.66 0.00 0.00 0.00
Minimum of Months 171.00 77.95 93.05 119.36 48.21 0.00 0.00 0.00
Maximum of Months 394.90 165.51 229.39 699.88 544.25 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 396.93 276.74 120.19 448.69 444.63 0.00 0.00 0.00
February 370.47 248.33 122.13 456.63 387.17 0.00 0.00 0.00
March 333.18 173.63 159.55 446.93 269.89 0.00 0.00 0.00
April 249.53 81.23 168.30 371.97 219.83 0.00 0.00 0.00
May 201.61 23.43 178.18 319.35 143.02 0.00 0.00 0.00
June 186.41 10.37 176.04 350.50 87.77 0.00 0.00 0.00
July 188.46 14.05 174.40 371.71 60.78 0.00 0.00 0.00
August 225.00 42.03 182.97 452.19 51.34 0.00 0.00 0.00
September 247.45 92.04 155.41 424.95 119.68 0.00 0.00 0.00
October 358.73 232.38 126.34 530.69 245.53 0.00 0.00 0.00
November 385.92 256.09 129.83 509.47 321.38 0.00 0.00 0.00
December 391.26 275.26 116.01 469.04 393.03 0.00 0.00 0.00
                 
Annual Sum or Average 294.25 143.31 150.94 429.28 227.82 0.00 0.00 0.00
Minimum of Months 186.41 10.37 116.01 319.35 51.34 0.00 0.00 0.00
Maximum of Months 396.93 276.74 182.97 530.69 444.63 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 396.93 276.74 120.19 448.69 444.63 0.00 0.00 0.00
February 370.47 248.33 122.13 456.62 387.17 0.00 0.00 0.00
March 333.18 173.63 159.55 446.92 269.89 0.00 0.00 0.00
April 249.53 81.23 168.30 371.96 219.83 0.00 0.00 0.00
May 201.61 23.43 178.18 319.35 143.02 0.00 0.00 0.00
June 186.41 10.37 176.04 350.50 87.77 0.00 0.00 0.00
July 188.46 14.05 174.40 371.71 60.78 0.00 0.00 0.00
August 225.00 42.03 182.97 452.19 51.34 0.00 0.00 0.00
September 247.45 92.04 155.41 424.95 119.68 0.00 0.00 0.00
October 358.72 232.38 126.34 530.69 245.53 0.00 0.00 0.00
November 385.92 256.09 129.83 509.47 321.38 0.00 0.00 0.00
December 391.26 275.25 116.01 469.03 393.02 0.00 0.00 0.00
                 
Annual Sum or Average 294.25 143.31 150.94 429.28 227.82 0.00 0.00 0.00
Minimum of Months 186.41 10.37 116.01 319.35 51.34 0.00 0.00 0.00
Maximum of Months 396.93 276.74 182.97 530.69 444.63 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 396.93 276.74 120.19 448.69 444.63 0.00 0.00 0.00
February 370.47 248.33 122.13 456.63 387.17 0.00 0.00 0.00
March 333.18 173.63 159.55 446.93 269.89 0.00 0.00 0.00
April 249.53 81.23 168.30 371.97 219.83 0.00 0.00 0.00
May 201.61 23.43 178.18 319.35 143.02 0.00 0.00 0.00
June 186.41 10.37 176.04 350.50 87.77 0.00 0.00 0.00
July 188.46 14.05 174.40 371.71 60.78 0.00 0.00 0.00
August 225.00 42.03 182.97 452.19 51.34 0.00 0.00 0.00
September 247.45 92.04 155.41 424.95 119.68 0.00 0.00 0.00
October 358.73 232.38 126.34 530.69 245.53 0.00 0.00 0.00
November 385.92 256.09 129.83 509.47 321.38 0.00 0.00 0.00
December 391.26 275.26 116.01 469.04 393.03 0.00 0.00 0.00
                 
Annual Sum or Average 294.25 143.31 150.94 429.28 227.82 0.00 0.00 0.00
Minimum of Months 186.41 10.37 116.01 319.35 51.34 0.00 0.00 0.00
Maximum of Months 396.93 276.74 182.97 530.69 444.63 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 396.93 276.74 120.19 448.69 444.63 0.00 0.00 0.00
February 370.47 248.33 122.13 456.62 387.17 0.00 0.00 0.00
March 333.18 173.63 159.55 446.92 269.89 0.00 0.00 0.00
April 249.53 81.23 168.30 371.96 219.83 0.00 0.00 0.00
May 201.61 23.43 178.18 319.35 143.02 0.00 0.00 0.00
June 186.41 10.37 176.04 350.50 87.77 0.00 0.00 0.00
July 188.46 14.05 174.40 371.71 60.78 0.00 0.00 0.00
August 225.00 42.03 182.97 452.19 51.34 0.00 0.00 0.00
September 247.45 92.04 155.41 424.95 119.68 0.00 0.00 0.00
October 358.72 232.38 126.34 530.69 245.53 0.00 0.00 0.00
November 385.92 256.09 129.83 509.47 321.38 0.00 0.00 0.00
December 391.26 275.25 116.01 469.03 393.02 0.00 0.00 0.00
                 
Annual Sum or Average 294.25 143.31 150.94 429.28 227.82 0.00 0.00 0.00
Minimum of Months 186.41 10.37 116.01 319.35 51.34 0.00 0.00 0.00
Maximum of Months 396.93 276.74 182.97 530.69 444.63 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 396.91 276.73 120.19 448.67 444.61 0.00 0.00 0.00
February 370.45 248.32 122.13 456.60 387.16 0.00 0.00 0.00
March 333.16 173.62 159.54 446.91 269.88 0.00 0.00 0.00
April 249.52 81.22 168.29 371.95 219.82 0.00 0.00 0.00
May 201.60 23.43 178.17 319.34 143.02 0.00 0.00 0.00
June 186.40 10.37 176.03 350.48 87.77 0.00 0.00 0.00
July 188.45 14.05 174.40 371.70 60.78 0.00 0.00 0.00
August 224.99 42.03 182.96 452.17 51.33 0.00 0.00 0.00
September 247.44 92.03 155.40 424.93 119.67 0.00 0.00 0.00
October 358.71 232.37 126.34 530.67 245.52 0.00 0.00 0.00
November 385.91 256.08 129.83 509.45 321.36 0.00 0.00 0.00
December 391.25 275.24 116.00 469.02 393.01 0.00 0.00 0.00
                 
Annual Sum or Average 294.24 143.30 150.94 429.27 227.81 0.00 0.00 0.00
Minimum of Months 186.40 10.37 116.00 319.34 51.33 0.00 0.00 0.00
Maximum of Months 396.91 276.73 182.96 530.67 444.61 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 186.02 86.29 99.73 136.18 594.41 0.00 0.00 0.00
February 213.55 99.85 113.70 205.08 520.37 0.00 0.00 0.00
March 314.76 152.10 162.66 374.08 352.00 0.00 0.00 0.00
April 354.10 162.04 192.07 486.51 281.84 0.00 0.00 0.00
May 355.89 134.83 221.05 551.12 176.35 0.00 0.00 0.00
June 374.26 143.98 230.28 652.95 117.47 0.00 0.00 0.00
July 353.01 130.89 222.13 632.72 89.07 0.00 0.00 0.00
August 345.90 129.35 216.55 624.87 81.59 0.00 0.00 0.00
September 281.82 117.39 164.43 447.50 148.82 0.00 0.00 0.00
October 251.06 130.33 120.73 330.73 319.97 0.00 0.00 0.00
November 200.37 89.94 110.43 206.73 437.85 0.00 0.00 0.00
December 165.30 72.30 93.00 124.47 567.29 0.00 0.00 0.00
                 
Annual Sum or Average 283.36 120.86 162.50 398.77 306.17 0.00 0.00 0.00
Minimum of Months 165.30 72.30 93.00 124.47 81.59 0.00 0.00 0.00
Maximum of Months 374.26 162.04 230.28 652.95 594.41 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 186.02 86.29 99.73 136.18 594.41 0.00 0.00 0.00
February 213.55 99.85 113.70 205.08 520.37 0.00 0.00 0.00
March 314.76 152.10 162.66 374.08 352.00 0.00 0.00 0.00
April 354.10 162.04 192.07 486.51 281.84 0.00 0.00 0.00
May 355.89 134.83 221.05 551.12 176.35 0.00 0.00 0.00
June 374.26 143.98 230.28 652.95 117.47 0.00 0.00 0.00
July 353.01 130.89 222.13 632.72 89.07 0.00 0.00 0.00
August 345.90 129.35 216.55 624.87 81.59 0.00 0.00 0.00
September 281.82 117.39 164.43 447.50 148.82 0.00 0.00 0.00
October 251.06 130.33 120.73 330.73 319.97 0.00 0.00 0.00
November 200.37 89.94 110.43 206.73 437.85 0.00 0.00 0.00
December 165.30 72.30 93.00 124.47 567.29 0.00 0.00 0.00
                 
Annual Sum or Average 283.36 120.86 162.50 398.77 306.17 0.00 0.00 0.00
Minimum of Months 165.30 72.30 93.00 124.47 81.59 0.00 0.00 0.00
Maximum of Months 374.26 162.04 230.28 652.95 594.41 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 186.02 86.29 99.73 136.18 594.40 0.00 0.00 0.00
February 213.55 99.85 113.70 205.07 520.36 0.00 0.00 0.00
March 314.76 152.10 162.66 374.08 351.99 0.00 0.00 0.00
April 354.10 162.03 192.06 486.51 281.83 0.00 0.00 0.00
May 355.88 134.83 221.05 551.11 176.35 0.00 0.00 0.00
June 374.25 143.97 230.28 652.93 117.46 0.00 0.00 0.00
July 353.01 130.88 222.12 632.71 89.07 0.00 0.00 0.00
August 345.90 129.35 216.54 624.85 81.59 0.00 0.00 0.00
September 281.81 117.39 164.42 447.49 148.81 0.00 0.00 0.00
October 251.06 130.33 120.73 330.72 319.96 0.00 0.00 0.00
November 200.36 89.93 110.43 206.73 437.84 0.00 0.00 0.00
December 165.30 72.30 93.00 124.47 567.28 0.00 0.00 0.00
                 
Annual Sum or Average 283.35 120.86 162.49 398.77 306.16 0.00 0.00 0.00
Minimum of Months 165.30 72.30 93.00 124.47 81.59 0.00 0.00 0.00
Maximum of Months 374.25 162.03 230.28 652.93 594.40 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 371.10 0.00 371.10 55.86 2428.25 0.00 0.00 0.00
February 411.33 0.00 411.33 180.61 2005.50 0.00 0.00 0.00
March 577.48 0.00 577.48 403.39 1287.29 0.00 0.00 0.00
April 698.52 3.10 695.42 776.55 1017.97 0.00 0.00 0.00
May 835.42 26.66 808.75 1181.78 652.15 0.00 0.00 0.00
June 919.41 60.70 858.71 1683.41 406.04 0.00 0.00 0.00
July 867.47 42.17 825.30 1683.06 287.72 0.00 0.00 0.00
August 771.47 8.40 763.07 1538.56 234.13 0.00 0.00 0.00
September 583.16 0.08 583.08 884.76 551.38 0.00 0.00 0.00
October 443.39 0.00 443.39 402.16 1171.04 0.00 0.00 0.00
November 396.82 0.00 396.82 212.06 1596.84 0.00 0.00 0.00
December 343.05 0.00 343.05 60.10 2012.72 0.00 0.00 0.00
                 
Annual Sum or Average 602.59 11.81 590.78 758.44 1133.13 0.00 0.00 0.00
Minimum of Months 343.05 0.00 343.05 55.86 234.13 0.00 0.00 0.00
Maximum of Months 919.41 60.70 858.71 1683.41 2428.25 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_MID_ZN_2_WALL_EAST_WINDOW

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 543.32 245.06 298.25 384.66 1462.10 0.00 0.00 0.00
February 684.95 368.02 316.93 665.66 1222.61 0.00 0.00 0.00
March 861.75 392.29 469.46 974.57 808.41 0.00 0.00 0.00
April 1042.08 475.16 566.92 1435.01 653.82 0.00 0.00 0.00
May 1144.28 483.90 660.38 1752.07 439.52 0.00 0.00 0.00
June 1184.71 496.54 688.17 2067.99 279.00 0.00 0.00 0.00
July 1155.14 485.64 669.50 2084.01 199.69 0.00 0.00 0.00
August 1056.57 419.18 637.39 1941.79 162.83 0.00 0.00 0.00
September 868.36 384.75 483.61 1386.12 364.52 0.00 0.00 0.00
October 740.78 385.45 355.34 951.07 739.35 0.00 0.00 0.00
November 592.26 268.17 324.09 586.60 974.64 0.00 0.00 0.00
December 513.01 233.85 279.16 389.27 1212.43 0.00 0.00 0.00
                 
Annual Sum or Average 866.47 386.44 480.03 1221.13 707.25 0.00 0.00 0.00
Minimum of Months 513.01 233.85 279.16 384.66 162.83 0.00 0.00 0.00
Maximum of Months 1184.71 496.54 688.17 2084.01 1462.10 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 1984.69 1383.72 600.97 2246.81 2127.56 0.00 0.00 0.00
February 1852.38 1241.70 610.68 2281.73 1849.32 0.00 0.00 0.00
March 1665.92 868.18 797.74 2221.78 1307.76 0.00 0.00 0.00
April 1247.66 406.14 841.52 1855.31 1075.75 0.00 0.00 0.00
May 1008.06 117.16 890.89 1593.93 702.63 0.00 0.00 0.00
June 932.06 51.87 880.19 1758.85 436.84 0.00 0.00 0.00
July 942.29 70.26 872.03 1868.13 303.75 0.00 0.00 0.00
August 1125.03 210.16 914.87 2267.25 256.88 0.00 0.00 0.00
September 1237.25 460.19 777.06 2117.60 586.98 0.00 0.00 0.00
October 1793.66 1161.94 631.73 2639.19 1190.38 0.00 0.00 0.00
November 1929.66 1280.49 649.17 2542.61 1548.82 0.00 0.00 0.00
December 1956.35 1376.31 580.04 2354.45 1845.66 0.00 0.00 0.00
                 
Annual Sum or Average 1471.29 716.57 754.72 2145.36 1098.65 0.00 0.00 0.00
Minimum of Months 932.06 51.87 580.04 1593.93 256.88 0.00 0.00 0.00
Maximum of Months 1984.69 1383.72 914.87 2639.19 2127.56 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_MID_ZN_4_WALL_WEST_WINDOW

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 558.06 258.87 299.19 440.00 1566.62 0.00 0.00 0.00
February 640.65 299.54 341.11 654.36 1334.40 0.00 0.00 0.00
March 944.28 456.30 487.98 1158.02 907.80 0.00 0.00 0.00
April 1062.30 486.10 576.20 1497.54 742.53 0.00 0.00 0.00
May 1067.64 404.49 663.16 1661.48 496.23 0.00 0.00 0.00
June 1122.77 431.92 690.84 1975.70 323.31 0.00 0.00 0.00
July 1059.03 392.65 666.38 1928.96 230.64 0.00 0.00 0.00
August 1037.70 388.06 649.64 1910.67 199.75 0.00 0.00 0.00
September 845.44 352.16 493.28 1356.00 404.37 0.00 0.00 0.00
October 753.19 390.99 362.20 1019.49 831.23 0.00 0.00 0.00
November 601.10 269.80 331.29 668.56 1098.43 0.00 0.00 0.00
December 495.90 216.91 278.99 420.49 1345.61 0.00 0.00 0.00
                 
Annual Sum or Average 850.07 362.58 487.49 1227.31 787.22 0.00 0.00 0.00
Minimum of Months 495.90 216.91 278.99 420.49 199.75 0.00 0.00 0.00
Maximum of Months 1122.77 486.10 690.84 1975.70 1566.62 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 371.10 0.00 371.10 70.50 2249.87 0.00 0.00 0.00
February 411.33 0.00 411.33 200.04 1860.77 0.00 0.00 0.00
March 577.48 0.00 577.48 435.31 1181.35 0.00 0.00 0.00
April 698.52 3.10 695.42 792.17 969.37 0.00 0.00 0.00
May 835.42 26.66 808.75 1173.13 646.22 0.00 0.00 0.00
June 919.41 60.70 858.71 1661.47 415.24 0.00 0.00 0.00
July 867.47 42.17 825.30 1657.08 298.23 0.00 0.00 0.00
August 771.47 8.40 763.07 1513.74 245.59 0.00 0.00 0.00
September 583.16 0.08 583.08 881.52 536.54 0.00 0.00 0.00
October 443.39 0.00 443.39 427.88 1070.68 0.00 0.00 0.00
November 396.82 0.00 396.82 253.40 1431.09 0.00 0.00 0.00
December 343.05 0.00 343.05 78.52 1802.08 0.00 0.00 0.00
                 
Annual Sum or Average 602.59 11.81 590.78 765.20 1054.75 0.00 0.00 0.00
Minimum of Months 343.05 0.00 343.05 70.50 245.59 0.00 0.00 0.00
Maximum of Months 919.41 60.70 858.71 1661.47 2249.87 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 543.32 245.06 298.25 408.69 1351.71 0.00 0.00 0.00
February 684.95 368.02 316.93 688.30 1135.01 0.00 0.00 0.00
March 861.75 392.29 469.46 996.91 753.31 0.00 0.00 0.00
April 1042.08 475.16 566.92 1440.92 631.50 0.00 0.00 0.00
May 1144.28 483.90 660.38 1742.50 439.76 0.00 0.00 0.00
June 1184.71 496.54 688.17 2051.83 286.42 0.00 0.00 0.00
July 1155.14 485.64 669.50 2065.83 206.81 0.00 0.00 0.00
August 1056.57 419.18 637.39 1924.02 170.78 0.00 0.00 0.00
September 868.36 384.75 483.61 1381.32 358.38 0.00 0.00 0.00
October 740.78 385.45 355.34 967.95 687.66 0.00 0.00 0.00
November 592.26 268.17 324.09 626.09 880.42 0.00 0.00 0.00
December 513.01 233.85 279.16 418.49 1085.71 0.00 0.00 0.00
                 
Annual Sum or Average 866.47 386.44 480.03 1228.86 663.15 0.00 0.00 0.00
Minimum of Months 513.01 233.85 279.16 408.69 170.78 0.00 0.00 0.00
Maximum of Months 1184.71 496.54 688.17 2065.83 1351.71 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 1984.69 1383.72 600.97 2304.22 1955.31 0.00 0.00 0.00
February 1852.38 1241.70 610.68 2322.82 1711.94 0.00 0.00 0.00
March 1665.92 868.18 797.74 2247.62 1222.23 0.00 0.00 0.00
April 1247.66 406.14 841.52 1862.93 1033.13 0.00 0.00 0.00
May 1008.06 117.16 890.89 1582.00 697.53 0.00 0.00 0.00
June 932.06 51.87 880.19 1737.13 445.89 0.00 0.00 0.00
July 942.29 70.26 872.03 1842.58 314.43 0.00 0.00 0.00
August 1125.03 210.16 914.87 2242.21 269.35 0.00 0.00 0.00
September 1237.25 460.19 777.06 2109.17 577.22 0.00 0.00 0.00
October 1793.66 1161.94 631.73 2655.09 1113.23 0.00 0.00 0.00
November 1929.66 1280.49 649.17 2592.83 1413.67 0.00 0.00 0.00
December 1956.35 1376.31 580.04 2413.74 1660.63 0.00 0.00 0.00
                 
Annual Sum or Average 1471.29 716.57 754.72 2158.94 1030.81 0.00 0.00 0.00
Minimum of Months 932.06 51.87 580.04 1582.00 269.35 0.00 0.00 0.00
Maximum of Months 1984.69 1383.72 914.87 2655.09 1955.31 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 558.06 258.87 299.19 458.49 1452.81 0.00 0.00 0.00
February 640.65 299.54 341.11 668.50 1247.66 0.00 0.00 0.00
March 944.28 456.30 487.98 1172.18 848.58 0.00 0.00 0.00
April 1062.30 486.10 576.20 1501.25 715.06 0.00 0.00 0.00
May 1067.64 404.49 663.16 1653.20 492.52 0.00 0.00 0.00
June 1122.77 431.92 690.84 1960.26 327.29 0.00 0.00 0.00
July 1059.03 392.65 666.38 1913.59 235.27 0.00 0.00 0.00
August 1037.70 388.06 649.64 1895.28 205.52 0.00 0.00 0.00
September 845.44 352.16 493.28 1351.52 396.29 0.00 0.00 0.00
October 753.19 390.99 362.20 1030.13 775.63 0.00 0.00 0.00
November 601.10 269.80 331.29 692.90 1006.55 0.00 0.00 0.00
December 495.90 216.91 278.99 438.55 1225.85 0.00 0.00 0.00
                 
Annual Sum or Average 850.07 362.58 487.49 1230.96 741.40 0.00 0.00 0.00
Minimum of Months 495.90 216.91 278.99 438.55 205.52 0.00 0.00 0.00
Maximum of Months 1122.77 486.10 690.84 1960.26 1452.81 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.198791E+09 0.00 0.198791E+09 19989291.73 0.146820E+10
February 0.199017E+09 0.00 0.199017E+09 70250336.16 0.109738E+10
March 0.309346E+09 0.00 0.309346E+09 0.193509E+09 0.767356E+09
April 0.362112E+09 1606061.20 0.360506E+09 0.386646E+09 0.561196E+09
May 0.447516E+09 14282166.31 0.433234E+09 0.628061E+09 0.360918E+09
June 0.476624E+09 31468210.52 0.445155E+09 0.867984E+09 0.211389E+09
July 0.464685E+09 22588531.99 0.442097E+09 0.894390E+09 0.154704E+09
August 0.413261E+09 4501801.68 0.408759E+09 0.813975E+09 0.127935E+09
September 0.302309E+09 42556.45 0.302267E+09 0.450862E+09 0.303213E+09
October 0.237518E+09 0.00 0.237518E+09 0.195641E+09 0.699722E+09
November 0.205713E+09 0.00 0.205713E+09 83531057.94 0.945618E+09
December 0.183767E+09 0.00 0.183767E+09 17552864.17 0.127786E+10
           
Annual Sum or Average 0.380066E+10 74489328.14 0.372617E+10 0.462239E+10 0.797549E+10
Minimum of Months 0.183767E+09 0.00 0.183767E+09 17552864.17 0.127935E+09
Maximum of Months 0.476624E+09 31468210.52 0.445155E+09 0.894390E+09 0.146820E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.198788E+09 0.00 0.198788E+09 19988553.83 0.146820E+10
February 0.199014E+09 0.00 0.199014E+09 70248681.68 0.109738E+10
March 0.309342E+09 0.00 0.309342E+09 0.193505E+09 0.767355E+09
April 0.362107E+09 1606025.89 0.360501E+09 0.386640E+09 0.561194E+09
May 0.447510E+09 14281852.33 0.433228E+09 0.628052E+09 0.360917E+09
June 0.476617E+09 31467518.73 0.445149E+09 0.867974E+09 0.211387E+09
July 0.464678E+09 22588035.41 0.442090E+09 0.894380E+09 0.154703E+09
August 0.413255E+09 4501702.71 0.408754E+09 0.813966E+09 0.127934E+09
September 0.302305E+09 42555.51 0.302263E+09 0.450856E+09 0.303212E+09
October 0.237515E+09 0.00 0.237515E+09 0.195638E+09 0.699721E+09
November 0.205710E+09 0.00 0.205710E+09 83528711.63 0.945617E+09
December 0.183765E+09 0.00 0.183765E+09 17551946.39 0.127786E+10
           
Annual Sum or Average 0.380061E+10 74487690.58 0.372612E+10 0.462233E+10 0.797548E+10
Minimum of Months 0.183765E+09 0.00 0.183765E+09 17551946.39 0.127934E+09
Maximum of Months 0.476617E+09 31467518.73 0.445149E+09 0.894380E+09 0.146820E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.198789E+09 0.00 0.198789E+09 19988799.80 0.146820E+10
February 0.199015E+09 0.00 0.199015E+09 70249233.17 0.109738E+10
March 0.309343E+09 0.00 0.309343E+09 0.193507E+09 0.767355E+09
April 0.362109E+09 1606037.66 0.360502E+09 0.386642E+09 0.561195E+09
May 0.447512E+09 14281956.99 0.433230E+09 0.628055E+09 0.360918E+09
June 0.476619E+09 31467749.32 0.445151E+09 0.867978E+09 0.211388E+09
July 0.464681E+09 22588200.93 0.442092E+09 0.894384E+09 0.154703E+09
August 0.413257E+09 4501735.70 0.408755E+09 0.813969E+09 0.127934E+09
September 0.302307E+09 42555.83 0.302264E+09 0.450858E+09 0.303212E+09
October 0.237516E+09 0.00 0.237516E+09 0.195639E+09 0.699721E+09
November 0.205711E+09 0.00 0.205711E+09 83529493.73 0.945617E+09
December 0.183766E+09 0.00 0.183766E+09 17552252.32 0.127786E+10
           
Annual Sum or Average 0.380062E+10 74488236.43 0.372613E+10 0.462235E+10 0.797548E+10
Minimum of Months 0.183766E+09 0.00 0.183766E+09 17552252.32 0.127934E+09
Maximum of Months 0.476619E+09 31467749.32 0.445151E+09 0.894384E+09 0.146820E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.198788E+09 0.00 0.198788E+09 19988553.83 0.146820E+10
February 0.199014E+09 0.00 0.199014E+09 70248681.68 0.109738E+10
March 0.309342E+09 0.00 0.309342E+09 0.193505E+09 0.767355E+09
April 0.362107E+09 1606025.89 0.360501E+09 0.386640E+09 0.561194E+09
May 0.447510E+09 14281852.33 0.433228E+09 0.628052E+09 0.360917E+09
June 0.476617E+09 31467518.73 0.445149E+09 0.867974E+09 0.211387E+09
July 0.464678E+09 22588035.41 0.442090E+09 0.894380E+09 0.154703E+09
August 0.413255E+09 4501702.71 0.408754E+09 0.813966E+09 0.127934E+09
September 0.302305E+09 42555.51 0.302263E+09 0.450856E+09 0.303212E+09
October 0.237515E+09 0.00 0.237515E+09 0.195638E+09 0.699721E+09
November 0.205710E+09 0.00 0.205710E+09 83528711.63 0.945617E+09
December 0.183765E+09 0.00 0.183765E+09 17551946.39 0.127786E+10
           
Annual Sum or Average 0.380061E+10 74487690.58 0.372612E+10 0.462233E+10 0.797548E+10
Minimum of Months 0.183765E+09 0.00 0.183765E+09 17551946.39 0.127934E+09
Maximum of Months 0.476617E+09 31467518.73 0.445149E+09 0.894380E+09 0.146820E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW5

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.198780E+09 0.00 0.198780E+09 19987871.18 0.146814E+10
February 0.199007E+09 0.00 0.199007E+09 70246126.08 0.109734E+10
March 0.309330E+09 0.00 0.309330E+09 0.193498E+09 0.767324E+09
April 0.362093E+09 1605967.04 0.360487E+09 0.386625E+09 0.561172E+09
May 0.447493E+09 14281329.04 0.433212E+09 0.628028E+09 0.360903E+09
June 0.476599E+09 31466365.74 0.445132E+09 0.867941E+09 0.211379E+09
July 0.464661E+09 22587207.77 0.442074E+09 0.894346E+09 0.154697E+09
August 0.413240E+09 4501537.77 0.408738E+09 0.813935E+09 0.127929E+09
September 0.302294E+09 42553.96 0.302251E+09 0.450839E+09 0.303200E+09
October 0.237506E+09 0.00 0.237506E+09 0.195631E+09 0.699693E+09
November 0.205702E+09 0.00 0.205702E+09 83525736.09 0.945579E+09
December 0.183758E+09 0.00 0.183758E+09 17551391.93 0.127781E+10
           
Annual Sum or Average 0.380046E+10 74484961.31 0.372598E+10 0.462215E+10 0.797516E+10
Minimum of Months 0.183758E+09 0.00 0.183758E+09 17551391.93 0.127929E+09
Maximum of Months 0.476599E+09 31466365.74 0.445132E+09 0.894346E+09 0.146814E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.485078E+09 0.218795E+09 0.266283E+09 0.319705E+09 0.145774E+10
February 0.552351E+09 0.296774E+09 0.255577E+09 0.519086E+09 0.108427E+10
March 0.769377E+09 0.350243E+09 0.419134E+09 0.864736E+09 0.762231E+09
April 0.900364E+09 0.410543E+09 0.489821E+09 0.124802E+10 0.566661E+09
May 0.102162E+10 0.432029E+09 0.589593E+09 0.157688E+10 0.394102E+09
June 0.102360E+10 0.429017E+09 0.594585E+09 0.180014E+10 0.229706E+09
July 0.103132E+10 0.433583E+09 0.597740E+09 0.187461E+10 0.163360E+09
August 0.943319E+09 0.374248E+09 0.569071E+09 0.174566E+10 0.129120E+09
September 0.750271E+09 0.332425E+09 0.417845E+09 0.120197E+10 0.321714E+09
October 0.661379E+09 0.344132E+09 0.317248E+09 0.842690E+09 0.705896E+09
November 0.511721E+09 0.231705E+09 0.280016E+09 0.482557E+09 0.921586E+09
December 0.458024E+09 0.208785E+09 0.249239E+09 0.320588E+09 0.123149E+10
           
Annual Sum or Average 0.910843E+10 0.406228E+10 0.504615E+10 0.127966E+11 0.796788E+10
Minimum of Months 0.458024E+09 0.208785E+09 0.249239E+09 0.319705E+09 0.129120E+09
Maximum of Months 0.103132E+10 0.433583E+09 0.597740E+09 0.187461E+10 0.145774E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.485078E+09 0.218795E+09 0.266283E+09 0.319705E+09 0.145774E+10
February 0.552351E+09 0.296774E+09 0.255577E+09 0.519086E+09 0.108427E+10
March 0.769377E+09 0.350243E+09 0.419134E+09 0.864736E+09 0.762231E+09
April 0.900364E+09 0.410543E+09 0.489821E+09 0.124802E+10 0.566661E+09
May 0.102162E+10 0.432029E+09 0.589593E+09 0.157688E+10 0.394102E+09
June 0.102360E+10 0.429017E+09 0.594585E+09 0.180014E+10 0.229706E+09
July 0.103132E+10 0.433583E+09 0.597740E+09 0.187461E+10 0.163360E+09
August 0.943319E+09 0.374248E+09 0.569071E+09 0.174566E+10 0.129120E+09
September 0.750271E+09 0.332425E+09 0.417845E+09 0.120197E+10 0.321714E+09
October 0.661379E+09 0.344132E+09 0.317248E+09 0.842690E+09 0.705896E+09
November 0.511721E+09 0.231705E+09 0.280016E+09 0.482557E+09 0.921586E+09
December 0.458024E+09 0.208785E+09 0.249239E+09 0.320588E+09 0.123149E+10
           
Annual Sum or Average 0.910843E+10 0.406228E+10 0.504615E+10 0.127966E+11 0.796788E+10
Minimum of Months 0.458024E+09 0.208785E+09 0.249239E+09 0.319705E+09 0.129120E+09
Maximum of Months 0.103132E+10 0.433583E+09 0.597740E+09 0.187461E+10 0.145774E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.485069E+09 0.218791E+09 0.266279E+09 0.319699E+09 0.145771E+10
February 0.552341E+09 0.296769E+09 0.255572E+09 0.519076E+09 0.108425E+10
March 0.769363E+09 0.350237E+09 0.419127E+09 0.864720E+09 0.762217E+09
April 0.900347E+09 0.410535E+09 0.489812E+09 0.124799E+10 0.566651E+09
May 0.102160E+10 0.432021E+09 0.589582E+09 0.157685E+10 0.394094E+09
June 0.102358E+10 0.429009E+09 0.594575E+09 0.180010E+10 0.229702E+09
July 0.103130E+10 0.433575E+09 0.597729E+09 0.187457E+10 0.163357E+09
August 0.943302E+09 0.374241E+09 0.569060E+09 0.174563E+10 0.129117E+09
September 0.750257E+09 0.332419E+09 0.417838E+09 0.120195E+10 0.321708E+09
October 0.661367E+09 0.344126E+09 0.317242E+09 0.842674E+09 0.705884E+09
November 0.511712E+09 0.231701E+09 0.280011E+09 0.482549E+09 0.921569E+09
December 0.458016E+09 0.208781E+09 0.249234E+09 0.320583E+09 0.123147E+10
           
Annual Sum or Average 0.910827E+10 0.406221E+10 0.504606E+10 0.127964E+11 0.796773E+10
Minimum of Months 0.458016E+09 0.208781E+09 0.249234E+09 0.319699E+09 0.129117E+09
Maximum of Months 0.103130E+10 0.433575E+09 0.597729E+09 0.187457E+10 0.145771E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.106314E+10 0.741215E+09 0.321924E+09 0.120177E+10 0.119088E+10
February 0.896239E+09 0.600772E+09 0.295467E+09 0.110467E+10 0.936649E+09
March 0.892383E+09 0.465055E+09 0.427328E+09 0.119705E+10 0.722874E+09
April 0.646778E+09 0.210538E+09 0.436239E+09 0.964134E+09 0.569805E+09
May 0.539991E+09 62760903.20 0.477230E+09 0.855352E+09 0.383071E+09
June 0.483173E+09 26886366.83 0.456287E+09 0.908487E+09 0.227497E+09
July 0.504761E+09 37637437.05 0.467123E+09 0.995596E+09 0.162792E+09
August 0.602647E+09 0.112576E+09 0.490071E+09 0.121115E+10 0.137498E+09
September 0.641382E+09 0.238559E+09 0.402823E+09 0.110146E+10 0.310204E+09
October 0.960813E+09 0.622414E+09 0.338400E+09 0.142141E+10 0.657630E+09
November 0.100032E+10 0.663792E+09 0.336525E+09 0.132056E+10 0.833010E+09
December 0.104796E+10 0.737246E+09 0.310714E+09 0.125627E+10 0.105268E+10
           
Annual Sum or Average 0.927958E+10 0.451945E+10 0.476013E+10 0.135379E+11 0.718459E+10
Minimum of Months 0.483173E+09 26886366.83 0.295467E+09 0.855352E+09 0.137498E+09
Maximum of Months 0.106314E+10 0.741215E+09 0.490071E+09 0.142141E+10 0.119088E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.106313E+10 0.741209E+09 0.321922E+09 0.120176E+10 0.119088E+10
February 0.896233E+09 0.600768E+09 0.295465E+09 0.110466E+10 0.936649E+09
March 0.892377E+09 0.465052E+09 0.427325E+09 0.119704E+10 0.722873E+09
April 0.646774E+09 0.210537E+09 0.436237E+09 0.964128E+09 0.569804E+09
May 0.539988E+09 62760443.29 0.477227E+09 0.855347E+09 0.383071E+09
June 0.483171E+09 26886169.80 0.456284E+09 0.908483E+09 0.227496E+09
July 0.504758E+09 37637161.24 0.467121E+09 0.995592E+09 0.162792E+09
August 0.602644E+09 0.112575E+09 0.490069E+09 0.121114E+10 0.137497E+09
September 0.641378E+09 0.238558E+09 0.402821E+09 0.110146E+10 0.310204E+09
October 0.960807E+09 0.622409E+09 0.338398E+09 0.142140E+10 0.657630E+09
November 0.100031E+10 0.663787E+09 0.336523E+09 0.132054E+10 0.833010E+09
December 0.104795E+10 0.737241E+09 0.310712E+09 0.125626E+10 0.105268E+10
           
Annual Sum or Average 0.927952E+10 0.451942E+10 0.476010E+10 0.135378E+11 0.718459E+10
Minimum of Months 0.483171E+09 26886169.80 0.295465E+09 0.855347E+09 0.137497E+09
Maximum of Months 0.106313E+10 0.741209E+09 0.490069E+09 0.142140E+10 0.119088E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.106314E+10 0.741215E+09 0.321924E+09 0.120177E+10 0.119088E+10
February 0.896239E+09 0.600772E+09 0.295467E+09 0.110467E+10 0.936649E+09
March 0.892383E+09 0.465055E+09 0.427328E+09 0.119705E+10 0.722874E+09
April 0.646778E+09 0.210538E+09 0.436239E+09 0.964134E+09 0.569805E+09
May 0.539991E+09 62760903.20 0.477230E+09 0.855352E+09 0.383071E+09
June 0.483173E+09 26886366.83 0.456287E+09 0.908487E+09 0.227497E+09
July 0.504761E+09 37637437.05 0.467123E+09 0.995596E+09 0.162792E+09
August 0.602647E+09 0.112576E+09 0.490071E+09 0.121115E+10 0.137498E+09
September 0.641382E+09 0.238559E+09 0.402823E+09 0.110146E+10 0.310204E+09
October 0.960813E+09 0.622414E+09 0.338400E+09 0.142141E+10 0.657630E+09
November 0.100032E+10 0.663792E+09 0.336525E+09 0.132056E+10 0.833010E+09
December 0.104796E+10 0.737246E+09 0.310714E+09 0.125627E+10 0.105268E+10
           
Annual Sum or Average 0.927958E+10 0.451945E+10 0.476013E+10 0.135379E+11 0.718459E+10
Minimum of Months 0.483173E+09 26886366.83 0.295467E+09 0.855352E+09 0.137498E+09
Maximum of Months 0.106314E+10 0.741215E+09 0.490071E+09 0.142141E+10 0.119088E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.106313E+10 0.741209E+09 0.321922E+09 0.120176E+10 0.119088E+10
February 0.896233E+09 0.600768E+09 0.295465E+09 0.110466E+10 0.936649E+09
March 0.892377E+09 0.465052E+09 0.427325E+09 0.119704E+10 0.722873E+09
April 0.646774E+09 0.210537E+09 0.436237E+09 0.964128E+09 0.569804E+09
May 0.539988E+09 62760443.29 0.477227E+09 0.855347E+09 0.383071E+09
June 0.483171E+09 26886169.80 0.456284E+09 0.908483E+09 0.227496E+09
July 0.504758E+09 37637161.24 0.467121E+09 0.995592E+09 0.162792E+09
August 0.602644E+09 0.112575E+09 0.490069E+09 0.121114E+10 0.137497E+09
September 0.641378E+09 0.238558E+09 0.402821E+09 0.110146E+10 0.310204E+09
October 0.960807E+09 0.622409E+09 0.338398E+09 0.142140E+10 0.657630E+09
November 0.100031E+10 0.663787E+09 0.336523E+09 0.132054E+10 0.833010E+09
December 0.104795E+10 0.737241E+09 0.310712E+09 0.125626E+10 0.105268E+10
           
Annual Sum or Average 0.927952E+10 0.451942E+10 0.476010E+10 0.135378E+11 0.718459E+10
Minimum of Months 0.483171E+09 26886169.80 0.295465E+09 0.855347E+09 0.137497E+09
Maximum of Months 0.106313E+10 0.741209E+09 0.490069E+09 0.142140E+10 0.119088E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW5

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.106309E+10 0.741182E+09 0.321910E+09 0.120172E+10 0.119084E+10
February 0.896200E+09 0.600746E+09 0.295454E+09 0.110462E+10 0.936611E+09
March 0.892344E+09 0.465035E+09 0.427309E+09 0.119700E+10 0.722844E+09
April 0.646750E+09 0.210529E+09 0.436221E+09 0.964092E+09 0.569781E+09
May 0.539967E+09 62758143.71 0.477209E+09 0.855315E+09 0.383056E+09
June 0.483152E+09 26885184.68 0.456267E+09 0.908448E+09 0.227487E+09
July 0.504739E+09 37635782.20 0.467103E+09 0.995554E+09 0.162785E+09
August 0.602621E+09 0.112571E+09 0.490050E+09 0.121110E+10 0.137492E+09
September 0.641354E+09 0.238549E+09 0.402805E+09 0.110142E+10 0.310191E+09
October 0.960772E+09 0.622387E+09 0.338385E+09 0.142134E+10 0.657604E+09
November 0.100027E+10 0.663763E+09 0.336510E+09 0.132050E+10 0.832976E+09
December 0.104791E+10 0.737214E+09 0.310700E+09 0.125622E+10 0.105264E+10
           
Annual Sum or Average 0.927918E+10 0.451925E+10 0.475992E+10 0.135373E+11 0.718430E+10
Minimum of Months 0.483152E+09 26885184.68 0.295454E+09 0.855315E+09 0.137492E+09
Maximum of Months 0.106309E+10 0.741182E+09 0.490050E+09 0.142134E+10 0.119084E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.498243E+09 0.231120E+09 0.267123E+09 0.364753E+09 0.159208E+10
February 0.516627E+09 0.241554E+09 0.275072E+09 0.496120E+09 0.125888E+10
March 0.843065E+09 0.407388E+09 0.435677E+09 0.100194E+10 0.942785E+09
April 0.917838E+09 0.419999E+09 0.497839E+09 0.126105E+10 0.730517E+09
May 0.953203E+09 0.361131E+09 0.592072E+09 0.147612E+10 0.472343E+09
June 0.970082E+09 0.373186E+09 0.596896E+09 0.169244E+10 0.304474E+09
July 0.945509E+09 0.350563E+09 0.594946E+09 0.169469E+10 0.238567E+09
August 0.926464E+09 0.346461E+09 0.580003E+09 0.167364E+10 0.218541E+09
September 0.730466E+09 0.304271E+09 0.426195E+09 0.115992E+10 0.385730E+09
October 0.672451E+09 0.349076E+09 0.323375E+09 0.885826E+09 0.857007E+09
November 0.519353E+09 0.233112E+09 0.286240E+09 0.535841E+09 0.113491E+10
December 0.442744E+09 0.193657E+09 0.249087E+09 0.333389E+09 0.151944E+10
           
Annual Sum or Average 0.893604E+10 0.381152E+10 0.512453E+10 0.125757E+11 0.965528E+10
Minimum of Months 0.442744E+09 0.193657E+09 0.249087E+09 0.333389E+09 0.218541E+09
Maximum of Months 0.970082E+09 0.419999E+09 0.596896E+09 0.169469E+10 0.159208E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.498243E+09 0.231120E+09 0.267123E+09 0.364753E+09 0.159208E+10
February 0.516627E+09 0.241554E+09 0.275072E+09 0.496120E+09 0.125888E+10
March 0.843065E+09 0.407388E+09 0.435677E+09 0.100194E+10 0.942785E+09
April 0.917838E+09 0.419999E+09 0.497839E+09 0.126105E+10 0.730517E+09
May 0.953203E+09 0.361131E+09 0.592072E+09 0.147612E+10 0.472343E+09
June 0.970082E+09 0.373186E+09 0.596896E+09 0.169244E+10 0.304474E+09
July 0.945509E+09 0.350563E+09 0.594946E+09 0.169469E+10 0.238567E+09
August 0.926464E+09 0.346461E+09 0.580003E+09 0.167364E+10 0.218541E+09
September 0.730466E+09 0.304271E+09 0.426195E+09 0.115992E+10 0.385730E+09
October 0.672451E+09 0.349076E+09 0.323375E+09 0.885826E+09 0.857007E+09
November 0.519353E+09 0.233112E+09 0.286240E+09 0.535841E+09 0.113491E+10
December 0.442744E+09 0.193657E+09 0.249087E+09 0.333389E+09 0.151944E+10
           
Annual Sum or Average 0.893604E+10 0.381152E+10 0.512453E+10 0.125757E+11 0.965528E+10
Minimum of Months 0.442744E+09 0.193657E+09 0.249087E+09 0.333389E+09 0.218541E+09
Maximum of Months 0.970082E+09 0.419999E+09 0.596896E+09 0.169469E+10 0.159208E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.498234E+09 0.231116E+09 0.267118E+09 0.364746E+09 0.159205E+10
February 0.516617E+09 0.241550E+09 0.275067E+09 0.496111E+09 0.125886E+10
March 0.843049E+09 0.407380E+09 0.435669E+09 0.100192E+10 0.942768E+09
April 0.917821E+09 0.419991E+09 0.497830E+09 0.126102E+10 0.730504E+09
May 0.953186E+09 0.361124E+09 0.592061E+09 0.147610E+10 0.472335E+09
June 0.970064E+09 0.373179E+09 0.596885E+09 0.169240E+10 0.304468E+09
July 0.945492E+09 0.350556E+09 0.594936E+09 0.169466E+10 0.238563E+09
August 0.926447E+09 0.346455E+09 0.579993E+09 0.167361E+10 0.218537E+09
September 0.730453E+09 0.304266E+09 0.426187E+09 0.115989E+10 0.385723E+09
October 0.672438E+09 0.349069E+09 0.323369E+09 0.885810E+09 0.856992E+09
November 0.519343E+09 0.233108E+09 0.286235E+09 0.535832E+09 0.113489E+10
December 0.442736E+09 0.193653E+09 0.249083E+09 0.333383E+09 0.151941E+10
           
Annual Sum or Average 0.893588E+10 0.381145E+10 0.512443E+10 0.125755E+11 0.965510E+10
Minimum of Months 0.442736E+09 0.193653E+09 0.249083E+09 0.333383E+09 0.218537E+09
Maximum of Months 0.970064E+09 0.419991E+09 0.596885E+09 0.169466E+10 0.159205E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.993954E+09 0.00 0.993954E+09 0.149610E+09 0.650383E+10
February 0.995084E+09 0.00 0.995084E+09 0.436921E+09 0.485172E+10
March 0.154673E+10 0.00 0.154673E+10 0.108044E+10 0.344788E+10
April 0.181056E+10 8030357.15 0.180253E+10 0.201283E+10 0.263858E+10
May 0.223758E+10 71411286.64 0.216617E+10 0.316527E+10 0.174671E+10
June 0.238312E+10 0.157342E+09 0.222578E+10 0.436340E+10 0.105245E+10
July 0.232342E+10 0.112943E+09 0.221048E+10 0.450790E+10 0.770630E+09
August 0.206630E+10 22509151.83 0.204380E+10 0.412087E+10 0.627088E+09
September 0.151155E+10 212783.61 0.151133E+10 0.229329E+10 0.142918E+10
October 0.118759E+10 0.00 0.118759E+10 0.107714E+10 0.313651E+10
November 0.102856E+10 0.00 0.102856E+10 0.549672E+09 0.413902E+10
December 0.918837E+09 0.00 0.918837E+09 0.160960E+09 0.539086E+10
           
Annual Sum or Average 0.190033E+11 0.372449E+09 0.186308E+11 0.239183E+11 0.357345E+11
Minimum of Months 0.918837E+09 0.00 0.918837E+09 0.149610E+09 0.627088E+09
Maximum of Months 0.238312E+10 0.157342E+09 0.222578E+10 0.450790E+10 0.650383E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_MID_ZN_2_WALL_EAST_WINDOW

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.145522E+10 0.656378E+09 0.798842E+09 0.103027E+10 0.391609E+10
February 0.165704E+10 0.890313E+09 0.766723E+09 0.161036E+10 0.295774E+10
March 0.230811E+10 0.105072E+10 0.125739E+10 0.261030E+10 0.216525E+10
April 0.270106E+10 0.123161E+10 0.146945E+10 0.371954E+10 0.169471E+10
May 0.306484E+10 0.129607E+10 0.176876E+10 0.469276E+10 0.117722E+10
June 0.307078E+10 0.128704E+10 0.178374E+10 0.536023E+10 0.723162E+09
July 0.309394E+10 0.130073E+10 0.179320E+10 0.558182E+10 0.534844E+09
August 0.282993E+10 0.112273E+10 0.170720E+10 0.520088E+10 0.436126E+09
September 0.225079E+10 0.997266E+09 0.125352E+10 0.359282E+10 0.944838E+09
October 0.198412E+10 0.103239E+10 0.951733E+09 0.254734E+10 0.198028E+10
November 0.153515E+10 0.695109E+09 0.840039E+09 0.152046E+10 0.252625E+10
December 0.137406E+10 0.626349E+09 0.747709E+09 0.104263E+10 0.324737E+10
           
Annual Sum or Average 0.273250E+11 0.121867E+11 0.151383E+11 0.385094E+11 0.223039E+11
Minimum of Months 0.137406E+10 0.626349E+09 0.747709E+09 0.103027E+10 0.436126E+09
Maximum of Months 0.309394E+10 0.130073E+10 0.179320E+10 0.558182E+10 0.391609E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.531579E+10 0.370615E+10 0.160964E+10 0.601786E+10 0.569845E+10
February 0.448128E+10 0.300392E+10 0.147735E+10 0.551997E+10 0.447388E+10
March 0.446199E+10 0.232533E+10 0.213666E+10 0.595083E+10 0.350271E+10
April 0.323393E+10 0.105271E+10 0.218122E+10 0.480896E+10 0.278833E+10
May 0.269998E+10 0.313811E+09 0.238617E+10 0.426919E+10 0.188191E+10
June 0.241589E+10 0.134435E+09 0.228145E+10 0.455895E+10 0.113229E+10
July 0.252383E+10 0.188191E+09 0.233564E+10 0.500361E+10 0.813558E+09
August 0.301327E+10 0.562890E+09 0.245038E+10 0.607260E+10 0.688025E+09
September 0.320696E+10 0.119282E+10 0.201414E+10 0.548881E+10 0.152145E+10
October 0.480415E+10 0.311213E+10 0.169202E+10 0.706881E+10 0.318832E+10
November 0.500168E+10 0.331903E+10 0.168265E+10 0.659045E+10 0.401454E+10
December 0.523990E+10 0.368631E+10 0.155359E+10 0.630616E+10 0.494341E+10
           
Annual Sum or Average 0.463986E+11 0.225977E+11 0.238009E+11 0.676562E+11 0.346469E+11
Minimum of Months 0.241589E+10 0.134435E+09 0.147735E+10 0.426919E+10 0.688025E+09
Maximum of Months 0.531579E+10 0.370615E+10 0.245038E+10 0.706881E+10 0.569845E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_MID_ZN_4_WALL_WEST_WINDOW

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.149471E+10 0.693353E+09 0.801361E+09 0.117851E+10 0.419604E+10
February 0.154986E+10 0.724655E+09 0.825209E+09 0.158302E+10 0.322817E+10
March 0.252917E+10 0.122215E+10 0.130702E+10 0.310165E+10 0.243145E+10
April 0.275349E+10 0.125998E+10 0.149350E+10 0.388163E+10 0.192463E+10
May 0.285958E+10 0.108338E+10 0.177620E+10 0.445012E+10 0.132909E+10
June 0.291021E+10 0.111955E+10 0.179067E+10 0.512100E+10 0.838023E+09
July 0.283650E+10 0.105168E+10 0.178482E+10 0.516654E+10 0.617750E+09
August 0.277936E+10 0.103937E+10 0.173999E+10 0.511754E+10 0.535012E+09
September 0.219138E+10 0.912804E+09 0.127857E+10 0.351474E+10 0.104813E+10
October 0.201733E+10 0.104722E+10 0.970115E+09 0.273061E+10 0.222636E+10
November 0.155804E+10 0.699329E+09 0.858712E+09 0.173290E+10 0.284713E+10
December 0.132822E+10 0.580965E+09 0.747255E+09 0.112625E+10 0.360408E+10
           
Annual Sum or Average 0.268079E+11 0.114344E+11 0.153734E+11 0.387045E+11 0.248259E+11
Minimum of Months 0.132822E+10 0.580965E+09 0.747255E+09 0.112625E+10 0.535012E+09
Maximum of Months 0.291021E+10 0.125998E+10 0.179067E+10 0.516654E+10 0.419604E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.993954E+09 0.00 0.993954E+09 0.188840E+09 0.602606E+10
February 0.995084E+09 0.00 0.995084E+09 0.483931E+09 0.450158E+10
March 0.154673E+10 0.00 0.154673E+10 0.116593E+10 0.316413E+10
April 0.181056E+10 8030357.15 0.180253E+10 0.205330E+10 0.251260E+10
May 0.223758E+10 71411286.64 0.216617E+10 0.314211E+10 0.173082E+10
June 0.238312E+10 0.157342E+09 0.222578E+10 0.430654E+10 0.107631E+10
July 0.232342E+10 0.112943E+09 0.221048E+10 0.443831E+10 0.798775E+09
August 0.206630E+10 22509151.83 0.204380E+10 0.405441E+10 0.657787E+09
September 0.151155E+10 212783.61 0.151133E+10 0.228489E+10 0.139071E+10
October 0.118759E+10 0.00 0.118759E+10 0.114604E+10 0.286770E+10
November 0.102856E+10 0.00 0.102856E+10 0.656804E+09 0.370938E+10
December 0.918837E+09 0.00 0.918837E+09 0.210297E+09 0.482670E+10
           
Annual Sum or Average 0.190033E+11 0.372449E+09 0.186308E+11 0.241314E+11 0.332626E+11
Minimum of Months 0.918837E+09 0.00 0.918837E+09 0.188840E+09 0.657787E+09
Maximum of Months 0.238312E+10 0.157342E+09 0.222578E+10 0.443831E+10 0.602606E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.145522E+10 0.656378E+09 0.798842E+09 0.109463E+10 0.362043E+10
February 0.165704E+10 0.890313E+09 0.766723E+09 0.166514E+10 0.274582E+10
March 0.230811E+10 0.105072E+10 0.125739E+10 0.267013E+10 0.201766E+10
April 0.270106E+10 0.123161E+10 0.146945E+10 0.373486E+10 0.163684E+10
May 0.306484E+10 0.129607E+10 0.176876E+10 0.466712E+10 0.117785E+10
June 0.307078E+10 0.128704E+10 0.178374E+10 0.531834E+10 0.742396E+09
July 0.309394E+10 0.130073E+10 0.179320E+10 0.553313E+10 0.553908E+09
August 0.282993E+10 0.112273E+10 0.170720E+10 0.515330E+10 0.457423E+09
September 0.225079E+10 0.997266E+09 0.125352E+10 0.358038E+10 0.928924E+09
October 0.198412E+10 0.103239E+10 0.951733E+09 0.259256E+10 0.184183E+10
November 0.153515E+10 0.695109E+09 0.840039E+09 0.162282E+10 0.228205E+10
December 0.137406E+10 0.626349E+09 0.747709E+09 0.112089E+10 0.290798E+10
           
Annual Sum or Average 0.273250E+11 0.121867E+11 0.151383E+11 0.387533E+11 0.209131E+11
Minimum of Months 0.137406E+10 0.626349E+09 0.747709E+09 0.109463E+10 0.457423E+09
Maximum of Months 0.309394E+10 0.130073E+10 0.179320E+10 0.553313E+10 0.362043E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.531579E+10 0.370615E+10 0.160964E+10 0.617162E+10 0.523711E+10
February 0.448128E+10 0.300392E+10 0.147735E+10 0.561935E+10 0.414152E+10
March 0.446199E+10 0.232533E+10 0.213666E+10 0.602003E+10 0.327363E+10
April 0.323393E+10 0.105271E+10 0.218122E+10 0.482871E+10 0.267788E+10
May 0.269998E+10 0.313811E+09 0.238617E+10 0.423724E+10 0.186827E+10
June 0.241589E+10 0.134435E+09 0.228145E+10 0.450265E+10 0.115575E+10
July 0.252383E+10 0.188191E+09 0.233564E+10 0.493517E+10 0.842167E+09
August 0.301327E+10 0.562890E+09 0.245038E+10 0.600553E+10 0.721437E+09
September 0.320696E+10 0.119282E+10 0.201414E+10 0.546697E+10 0.149616E+10
October 0.480415E+10 0.311213E+10 0.169202E+10 0.711139E+10 0.298167E+10
November 0.500168E+10 0.331903E+10 0.168265E+10 0.672061E+10 0.366423E+10
December 0.523990E+10 0.368631E+10 0.155359E+10 0.646495E+10 0.444784E+10
           
Annual Sum or Average 0.463986E+11 0.225977E+11 0.238009E+11 0.680842E+11 0.325077E+11
Minimum of Months 0.241589E+10 0.134435E+09 0.147735E+10 0.423724E+10 0.721437E+09
Maximum of Months 0.531579E+10 0.370615E+10 0.245038E+10 0.711139E+10 0.523711E+10



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.149471E+10 0.693353E+09 0.801361E+09 0.122803E+10 0.389120E+10
February 0.154986E+10 0.724655E+09 0.825209E+09 0.161724E+10 0.301834E+10
March 0.252917E+10 0.122215E+10 0.130702E+10 0.313956E+10 0.227283E+10
April 0.275349E+10 0.125998E+10 0.149350E+10 0.389124E+10 0.185343E+10
May 0.285958E+10 0.108338E+10 0.177620E+10 0.442793E+10 0.131915E+10
June 0.291021E+10 0.111955E+10 0.179067E+10 0.508098E+10 0.848346E+09
July 0.283650E+10 0.105168E+10 0.178482E+10 0.512536E+10 0.630142E+09
August 0.277936E+10 0.103937E+10 0.173999E+10 0.507631E+10 0.550466E+09
September 0.219138E+10 0.912804E+09 0.127857E+10 0.350315E+10 0.102718E+10
October 0.201733E+10 0.104722E+10 0.970115E+09 0.275911E+10 0.207745E+10
November 0.155804E+10 0.699329E+09 0.858712E+09 0.179601E+10 0.260897E+10
December 0.132822E+10 0.580965E+09 0.747255E+09 0.117461E+10 0.328333E+10
           
Annual Sum or Average 0.268079E+11 0.114344E+11 0.153734E+11 0.388195E+11 0.233808E+11
Minimum of Months 0.132822E+10 0.580965E+09 0.747255E+09 0.117461E+10 0.550466E+09
Maximum of Months 0.291021E+10 0.125998E+10 0.179067E+10 0.512536E+10 0.389120E+10



Table of Contents

Report: WindowZoneSummaryMonthly

For: BASEMENT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: CORE_BOTTOM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: CORE_MID

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: CORE_TOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_BOT_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 37.31 2740.79 371.09 0.00 371.09 0.00 0.00
February 145.19 2268.04 411.32 0.00 411.32 0.00 0.00
March 361.23 1432.48 577.47 0.00 577.47 0.00 0.00
April 745.83 1082.54 698.51 3.10 695.41 0.00 0.00
May 1172.43 673.75 835.40 26.66 808.74 0.00 0.00
June 1674.33 407.77 919.40 60.70 858.70 0.00 0.00
July 1669.61 288.80 867.45 42.17 825.28 0.00 0.00
August 1519.49 238.82 771.46 8.40 763.05 0.00 0.00
September 869.70 584.90 583.15 0.08 583.07 0.00 0.00
October 365.21 1306.22 443.39 0.00 443.39 0.00 0.00
November 161.13 1824.09 396.82 0.00 396.82 0.00 0.00
December 32.77 2385.47 343.05 0.00 343.05 0.00 0.00
               
Annual Sum or Average 732.86 1264.49 602.58 11.81 590.77 0.00 0.00
Minimum of Months 32.77 238.82 343.05 0.00 343.05 0.00 0.00
Maximum of Months 1674.33 2740.79 919.40 60.70 858.70 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_BOT_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 358.09 1632.77 543.32 245.06 298.25 0.00 0.00
February 643.70 1344.57 684.95 368.02 316.93 0.00 0.00
March 968.56 853.75 861.75 392.29 469.46 0.00 0.00
April 1444.46 655.85 1042.08 475.16 566.92 0.00 0.00
May 1766.21 441.42 1144.28 483.90 660.38 0.00 0.00
June 2083.48 265.86 1184.72 496.54 688.17 0.00 0.00
July 2099.68 182.97 1155.15 485.64 669.51 0.00 0.00
August 1955.25 144.62 1056.58 419.18 637.40 0.00 0.00
September 1391.16 372.35 868.36 384.75 483.61 0.00 0.00
October 943.87 790.65 740.79 385.45 355.34 0.00 0.00
November 558.51 1066.64 592.27 268.18 324.09 0.00 0.00
December 359.08 1379.35 513.02 233.85 279.16 0.00 0.00
               
Annual Sum or Average 1217.33 757.97 866.47 386.44 480.03 0.00 0.00
Minimum of Months 358.09 144.62 513.02 233.85 279.16 0.00 0.00
Maximum of Months 2099.68 1632.77 1184.72 496.54 688.17 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_BOT_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 2243.42 2223.11 1984.63 1383.67 600.96 0.00 0.00
February 2283.10 1935.85 1852.32 1241.66 610.66 0.00 0.00
March 2234.61 1349.44 1665.87 868.15 797.72 0.00 0.00
April 1859.81 1099.15 1247.63 406.13 841.50 0.00 0.00
May 1596.74 715.11 1008.04 117.16 890.88 0.00 0.00
June 1752.46 438.84 932.04 51.86 880.17 0.00 0.00
July 1858.55 303.90 942.27 70.26 872.01 0.00 0.00
August 2260.93 256.68 1125.00 210.15 914.85 0.00 0.00
September 2124.72 598.38 1237.22 460.18 777.04 0.00 0.00
October 2653.43 1227.65 1793.61 1161.90 631.71 0.00 0.00
November 2547.34 1606.87 1929.60 1280.45 649.15 0.00 0.00
December 2345.16 1965.11 1956.29 1376.26 580.03 0.00 0.00
               
Annual Sum or Average 2146.40 1139.10 1471.25 716.55 754.71 0.00 0.00
Minimum of Months 1596.74 256.68 932.04 51.86 580.03 0.00 0.00
Maximum of Months 2653.43 2223.11 1984.63 1383.67 914.85 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_BOT_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 408.55 1783.23 558.06 258.87 299.19 0.00 0.00
February 615.22 1561.11 640.65 299.54 341.11 0.00 0.00
March 1122.24 1055.98 944.29 456.30 487.99 0.00 0.00
April 1459.54 845.50 1062.31 486.11 576.20 0.00 0.00
May 1653.35 529.06 1067.65 404.49 663.16 0.00 0.00
June 1958.83 352.40 1122.77 431.93 690.85 0.00 0.00
July 1898.16 267.21 1059.03 392.65 666.38 0.00 0.00
August 1874.59 244.78 1037.70 388.06 649.64 0.00 0.00
September 1342.49 446.44 845.44 352.16 493.28 0.00 0.00
October 992.18 959.90 753.19 390.99 362.20 0.00 0.00
November 620.18 1313.54 601.10 269.80 331.29 0.00 0.00
December 373.42 1701.87 495.90 216.91 278.99 0.00 0.00
               
Annual Sum or Average 1196.31 918.49 850.08 362.59 487.49 0.00 0.00
Minimum of Months 373.42 244.78 495.90 216.91 278.99 0.00 0.00
Maximum of Months 1958.83 1783.23 1122.77 486.11 690.85 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_MID_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 55.86 2428.25 371.10 0.00 371.10 0.00 0.00
February 180.61 2005.50 411.33 0.00 411.33 0.00 0.00
March 403.39 1287.29 577.48 0.00 577.48 0.00 0.00
April 776.55 1017.97 698.52 3.10 695.42 0.00 0.00
May 1181.78 652.15 835.42 26.66 808.75 0.00 0.00
June 1683.41 406.04 919.41 60.70 858.71 0.00 0.00
July 1683.06 287.72 867.47 42.17 825.30 0.00 0.00
August 1538.56 234.13 771.47 8.40 763.07 0.00 0.00
September 884.76 551.38 583.16 0.08 583.08 0.00 0.00
October 402.16 1171.04 443.39 0.00 443.39 0.00 0.00
November 212.06 1596.84 396.82 0.00 396.82 0.00 0.00
December 60.10 2012.72 343.05 0.00 343.05 0.00 0.00
               
Annual Sum or Average 758.44 1133.13 602.59 11.81 590.78 0.00 0.00
Minimum of Months 55.86 234.13 343.05 0.00 343.05 0.00 0.00
Maximum of Months 1683.41 2428.25 919.41 60.70 858.71 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_MID_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 384.66 1462.10 543.32 245.06 298.25 0.00 0.00
February 665.66 1222.61 684.95 368.02 316.93 0.00 0.00
March 974.57 808.41 861.75 392.29 469.46 0.00 0.00
April 1435.01 653.82 1042.08 475.16 566.92 0.00 0.00
May 1752.07 439.52 1144.28 483.90 660.38 0.00 0.00
June 2067.99 279.00 1184.71 496.54 688.17 0.00 0.00
July 2084.01 199.69 1155.14 485.64 669.50 0.00 0.00
August 1941.79 162.83 1056.57 419.18 637.39 0.00 0.00
September 1386.12 364.52 868.36 384.75 483.61 0.00 0.00
October 951.07 739.35 740.78 385.45 355.34 0.00 0.00
November 586.60 974.64 592.26 268.17 324.09 0.00 0.00
December 389.27 1212.43 513.01 233.85 279.16 0.00 0.00
               
Annual Sum or Average 1221.13 707.25 866.47 386.44 480.03 0.00 0.00
Minimum of Months 384.66 162.83 513.01 233.85 279.16 0.00 0.00
Maximum of Months 2084.01 1462.10 1184.71 496.54 688.17 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_MID_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 2246.81 2127.56 1984.69 1383.72 600.97 0.00 0.00
February 2281.73 1849.32 1852.38 1241.70 610.68 0.00 0.00
March 2221.78 1307.76 1665.92 868.18 797.74 0.00 0.00
April 1855.31 1075.75 1247.66 406.14 841.52 0.00 0.00
May 1593.93 702.63 1008.06 117.16 890.89 0.00 0.00
June 1758.85 436.84 932.06 51.87 880.19 0.00 0.00
July 1868.13 303.75 942.29 70.26 872.03 0.00 0.00
August 2267.25 256.88 1125.03 210.16 914.87 0.00 0.00
September 2117.60 586.98 1237.25 460.19 777.06 0.00 0.00
October 2639.19 1190.38 1793.66 1161.94 631.73 0.00 0.00
November 2542.61 1548.82 1929.66 1280.49 649.17 0.00 0.00
December 2354.45 1845.66 1956.35 1376.31 580.04 0.00 0.00
               
Annual Sum or Average 2145.36 1098.65 1471.29 716.57 754.72 0.00 0.00
Minimum of Months 1593.93 256.88 932.06 51.87 580.04 0.00 0.00
Maximum of Months 2639.19 2127.56 1984.69 1383.72 914.87 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_MID_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 440.00 1566.62 558.06 258.87 299.19 0.00 0.00
February 654.36 1334.40 640.65 299.54 341.11 0.00 0.00
March 1158.02 907.80 944.28 456.30 487.98 0.00 0.00
April 1497.54 742.53 1062.30 486.10 576.20 0.00 0.00
May 1661.48 496.23 1067.64 404.49 663.16 0.00 0.00
June 1975.70 323.31 1122.77 431.92 690.84 0.00 0.00
July 1928.96 230.64 1059.03 392.65 666.38 0.00 0.00
August 1910.67 199.75 1037.70 388.06 649.64 0.00 0.00
September 1356.00 404.37 845.44 352.16 493.28 0.00 0.00
October 1019.49 831.23 753.19 390.99 362.20 0.00 0.00
November 668.56 1098.43 601.10 269.80 331.29 0.00 0.00
December 420.49 1345.61 495.90 216.91 278.99 0.00 0.00
               
Annual Sum or Average 1227.31 787.22 850.07 362.58 487.49 0.00 0.00
Minimum of Months 420.49 199.75 495.90 216.91 278.99 0.00 0.00
Maximum of Months 1975.70 1566.62 1122.77 486.10 690.84 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_TOP_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 70.50 2249.87 371.10 0.00 371.10 0.00 0.00
February 200.04 1860.77 411.33 0.00 411.33 0.00 0.00
March 435.31 1181.35 577.48 0.00 577.48 0.00 0.00
April 792.17 969.37 698.52 3.10 695.42 0.00 0.00
May 1173.13 646.22 835.42 26.66 808.75 0.00 0.00
June 1661.47 415.24 919.41 60.70 858.71 0.00 0.00
July 1657.08 298.23 867.47 42.17 825.30 0.00 0.00
August 1513.74 245.59 771.47 8.40 763.07 0.00 0.00
September 881.52 536.54 583.16 0.08 583.08 0.00 0.00
October 427.88 1070.68 443.39 0.00 443.39 0.00 0.00
November 253.40 1431.09 396.82 0.00 396.82 0.00 0.00
December 78.52 1802.08 343.05 0.00 343.05 0.00 0.00
               
Annual Sum or Average 765.20 1054.75 602.59 11.81 590.78 0.00 0.00
Minimum of Months 70.50 245.59 343.05 0.00 343.05 0.00 0.00
Maximum of Months 1661.47 2249.87 919.41 60.70 858.71 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_TOP_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 408.69 1351.71 543.32 245.06 298.25 0.00 0.00
February 688.30 1135.01 684.95 368.02 316.93 0.00 0.00
March 996.91 753.31 861.75 392.29 469.46 0.00 0.00
April 1440.92 631.50 1042.08 475.16 566.92 0.00 0.00
May 1742.50 439.76 1144.28 483.90 660.38 0.00 0.00
June 2051.83 286.42 1184.71 496.54 688.17 0.00 0.00
July 2065.83 206.81 1155.14 485.64 669.50 0.00 0.00
August 1924.02 170.78 1056.57 419.18 637.39 0.00 0.00
September 1381.32 358.38 868.36 384.75 483.61 0.00 0.00
October 967.95 687.66 740.78 385.45 355.34 0.00 0.00
November 626.09 880.42 592.26 268.17 324.09 0.00 0.00
December 418.49 1085.71 513.01 233.85 279.16 0.00 0.00
               
Annual Sum or Average 1228.86 663.15 866.47 386.44 480.03 0.00 0.00
Minimum of Months 408.69 170.78 513.01 233.85 279.16 0.00 0.00
Maximum of Months 2065.83 1351.71 1184.71 496.54 688.17 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_TOP_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 2304.22 1955.31 1984.69 1383.72 600.97 0.00 0.00
February 2322.82 1711.94 1852.38 1241.70 610.68 0.00 0.00
March 2247.62 1222.23 1665.92 868.18 797.74 0.00 0.00
April 1862.93 1033.13 1247.66 406.14 841.52 0.00 0.00
May 1582.00 697.53 1008.06 117.16 890.89 0.00 0.00
June 1737.13 445.89 932.06 51.87 880.19 0.00 0.00
July 1842.58 314.43 942.29 70.26 872.03 0.00 0.00
August 2242.21 269.35 1125.03 210.16 914.87 0.00 0.00
September 2109.17 577.22 1237.25 460.19 777.06 0.00 0.00
October 2655.09 1113.23 1793.66 1161.94 631.73 0.00 0.00
November 2592.83 1413.67 1929.66 1280.49 649.17 0.00 0.00
December 2413.74 1660.63 1956.35 1376.31 580.04 0.00 0.00
               
Annual Sum or Average 2158.94 1030.81 1471.29 716.57 754.72 0.00 0.00
Minimum of Months 1582.00 269.35 932.06 51.87 580.04 0.00 0.00
Maximum of Months 2655.09 1955.31 1984.69 1383.72 914.87 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_TOP_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 458.49 1452.81 558.06 258.87 299.19 0.00 0.00
February 668.50 1247.66 640.65 299.54 341.11 0.00 0.00
March 1172.18 848.58 944.28 456.30 487.98 0.00 0.00
April 1501.25 715.06 1062.30 486.10 576.20 0.00 0.00
May 1653.20 492.52 1067.64 404.49 663.16 0.00 0.00
June 1960.26 327.29 1122.77 431.92 690.84 0.00 0.00
July 1913.59 235.27 1059.03 392.65 666.38 0.00 0.00
August 1895.28 205.52 1037.70 388.06 649.64 0.00 0.00
September 1351.52 396.29 845.44 352.16 493.28 0.00 0.00
October 1030.13 775.63 753.19 390.99 362.20 0.00 0.00
November 692.90 1006.55 601.10 269.80 331.29 0.00 0.00
December 438.55 1225.85 495.90 216.91 278.99 0.00 0.00
               
Annual Sum or Average 1230.96 741.40 850.07 362.58 487.49 0.00 0.00
Minimum of Months 438.55 205.52 495.90 216.91 278.99 0.00 0.00
Maximum of Months 1960.26 1452.81 1122.77 486.10 690.84 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: GROUNDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: MIDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: TOPFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: DATACENTER_BOT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: DATACENTER_MID_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: DATACENTER_TOP_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: DATACENTER_BASEMENT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: BASEMENT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: CORE_BOTTOM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: CORE_MID

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: CORE_TOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_BOT_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 99943070.37 0.734094E+10 0.993936E+09 0.00 0.993936E+09 0.00 0.00
February 0.351243E+09 0.548685E+10 0.995068E+09 0.00 0.995068E+09 0.00 0.00
March 0.967524E+09 0.383675E+10 0.154670E+10 0.00 0.154670E+10 0.00 0.00
April 0.193319E+10 0.280595E+10 0.181053E+10 8030117.67 0.180250E+10 0.00 0.00
May 0.314025E+10 0.180457E+10 0.223754E+10 71409157.01 0.216613E+10 0.00 0.00
June 0.433985E+10 0.105693E+10 0.238307E+10 0.157337E+09 0.222574E+10 0.00 0.00
July 0.447188E+10 0.773510E+09 0.232338E+10 0.112940E+09 0.221044E+10 0.00 0.00
August 0.406981E+10 0.639666E+09 0.206627E+10 22508480.56 0.204376E+10 0.00 0.00
September 0.225427E+10 0.151605E+10 0.151152E+10 212777.26 0.151131E+10 0.00 0.00
October 0.978189E+09 0.349858E+10 0.118757E+10 0.00 0.118757E+10 0.00 0.00
November 0.417644E+09 0.472805E+10 0.102854E+10 0.00 0.102854E+10 0.00 0.00
December 87760401.20 0.638923E+10 0.918820E+09 0.00 0.918820E+09 0.00 0.00
               
Annual Sum or Average 0.231116E+11 0.398771E+11 0.190030E+11 0.372438E+09 0.186305E+11 0.00 0.00
Minimum of Months 87760401.20 0.639666E+09 0.918820E+09 0.00 0.918820E+09 0.00 0.00
Maximum of Months 0.447188E+10 0.734094E+10 0.238307E+10 0.157337E+09 0.222574E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_BOT_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.959110E+09 0.437320E+10 0.145523E+10 0.656381E+09 0.798846E+09 0.00 0.00
February 0.155725E+10 0.325279E+10 0.165704E+10 0.890317E+09 0.766726E+09 0.00 0.00
March 0.259419E+10 0.228668E+10 0.230812E+10 0.105072E+10 0.125740E+10 0.00 0.00
April 0.374403E+10 0.169997E+10 0.270108E+10 0.123162E+10 0.146946E+10 0.00 0.00
May 0.473062E+10 0.118230E+10 0.306485E+10 0.129608E+10 0.176877E+10 0.00 0.00
June 0.540038E+10 0.689115E+09 0.307079E+10 0.128704E+10 0.178375E+10 0.00 0.00
July 0.562378E+10 0.490076E+09 0.309395E+10 0.130074E+10 0.179321E+10 0.00 0.00
August 0.523695E+10 0.387356E+09 0.282994E+10 0.112274E+10 0.170720E+10 0.00 0.00
September 0.360589E+10 0.965136E+09 0.225080E+10 0.997270E+09 0.125353E+10 0.00 0.00
October 0.252805E+10 0.211768E+10 0.198413E+10 0.103239E+10 0.951737E+09 0.00 0.00
November 0.144766E+10 0.276474E+10 0.153515E+10 0.695112E+09 0.840042E+09 0.00 0.00
December 0.961759E+09 0.369445E+10 0.137406E+10 0.626351E+09 0.747712E+09 0.00 0.00
               
Annual Sum or Average 0.383897E+11 0.239035E+11 0.273251E+11 0.121868E+11 0.151384E+11 0.00 0.00
Minimum of Months 0.959110E+09 0.387356E+09 0.137406E+10 0.626351E+09 0.747712E+09 0.00 0.00
Maximum of Months 0.562378E+10 0.437320E+10 0.309395E+10 0.130074E+10 0.179321E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_BOT_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.600878E+10 0.595437E+10 0.531563E+10 0.370603E+10 0.160960E+10 0.00 0.00
February 0.552327E+10 0.468321E+10 0.448114E+10 0.300382E+10 0.147732E+10 0.00 0.00
March 0.598519E+10 0.361434E+10 0.446186E+10 0.232525E+10 0.213662E+10 0.00 0.00
April 0.482062E+10 0.284900E+10 0.323385E+10 0.105268E+10 0.218117E+10 0.00 0.00
May 0.427671E+10 0.191534E+10 0.269992E+10 0.313801E+09 0.238612E+10 0.00 0.00
June 0.454239E+10 0.113747E+10 0.241584E+10 0.134430E+09 0.228141E+10 0.00 0.00
July 0.497793E+10 0.813953E+09 0.252378E+10 0.188185E+09 0.233559E+10 0.00 0.00
August 0.605568E+10 0.687481E+09 0.301320E+10 0.562872E+09 0.245033E+10 0.00 0.00
September 0.550726E+10 0.155101E+10 0.320688E+10 0.119278E+10 0.201409E+10 0.00 0.00
October 0.710695E+10 0.328812E+10 0.480401E+10 0.311203E+10 0.169198E+10 0.00 0.00
November 0.660270E+10 0.416502E+10 0.500153E+10 0.331892E+10 0.168261E+10 0.00 0.00
December 0.628129E+10 0.526335E+10 0.523974E+10 0.368619E+10 0.155355E+10 0.00 0.00
               
Annual Sum or Average 0.676887E+11 0.359227E+11 0.463974E+11 0.225970E+11 0.238004E+11 0.00 0.00
Minimum of Months 0.427671E+10 0.687481E+09 0.241584E+10 0.134430E+09 0.147732E+10 0.00 0.00
Maximum of Months 0.710695E+10 0.595437E+10 0.531563E+10 0.370603E+10 0.245033E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_BOT_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.109425E+10 0.477620E+10 0.149472E+10 0.693356E+09 0.801364E+09 0.00 0.00
February 0.148835E+10 0.377663E+10 0.154987E+10 0.724658E+09 0.825212E+09 0.00 0.00
March 0.300581E+10 0.282834E+10 0.252918E+10 0.122216E+10 0.130702E+10 0.00 0.00
April 0.378311E+10 0.219154E+10 0.275350E+10 0.125999E+10 0.149351E+10 0.00 0.00
May 0.442834E+10 0.141702E+10 0.285959E+10 0.108339E+10 0.177621E+10 0.00 0.00
June 0.507728E+10 0.913416E+09 0.291023E+10 0.111955E+10 0.179068E+10 0.00 0.00
July 0.508403E+10 0.715697E+09 0.283651E+10 0.105168E+10 0.178483E+10 0.00 0.00
August 0.502089E+10 0.655620E+09 0.277938E+10 0.103938E+10 0.174000E+10 0.00 0.00
September 0.347973E+10 0.115718E+10 0.219139E+10 0.912808E+09 0.127858E+10 0.00 0.00
October 0.265746E+10 0.257101E+10 0.201734E+10 0.104722E+10 0.970119E+09 0.00 0.00
November 0.160751E+10 0.340470E+10 0.155805E+10 0.699332E+09 0.858716E+09 0.00 0.00
December 0.100016E+10 0.455829E+10 0.132823E+10 0.580967E+09 0.747258E+09 0.00 0.00
               
Annual Sum or Average 0.377269E+11 0.289656E+11 0.268080E+11 0.114345E+11 0.153735E+11 0.00 0.00
Minimum of Months 0.100016E+10 0.655620E+09 0.132823E+10 0.580967E+09 0.747258E+09 0.00 0.00
Maximum of Months 0.508403E+10 0.477620E+10 0.291023E+10 0.125999E+10 0.179068E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_MID_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.149610E+09 0.650383E+10 0.993954E+09 0.00 0.993954E+09 0.00 0.00
February 0.436921E+09 0.485172E+10 0.995084E+09 0.00 0.995084E+09 0.00 0.00
March 0.108044E+10 0.344788E+10 0.154673E+10 0.00 0.154673E+10 0.00 0.00
April 0.201283E+10 0.263858E+10 0.181056E+10 8030357.15 0.180253E+10 0.00 0.00
May 0.316527E+10 0.174671E+10 0.223758E+10 71411286.64 0.216617E+10 0.00 0.00
June 0.436340E+10 0.105245E+10 0.238312E+10 0.157342E+09 0.222578E+10 0.00 0.00
July 0.450790E+10 0.770630E+09 0.232342E+10 0.112943E+09 0.221048E+10 0.00 0.00
August 0.412087E+10 0.627088E+09 0.206630E+10 22509151.83 0.204380E+10 0.00 0.00
September 0.229329E+10 0.142918E+10 0.151155E+10 212783.61 0.151133E+10 0.00 0.00
October 0.107714E+10 0.313651E+10 0.118759E+10 0.00 0.118759E+10 0.00 0.00
November 0.549672E+09 0.413902E+10 0.102856E+10 0.00 0.102856E+10 0.00 0.00
December 0.160960E+09 0.539086E+10 0.918837E+09 0.00 0.918837E+09 0.00 0.00
               
Annual Sum or Average 0.239183E+11 0.357345E+11 0.190033E+11 0.372449E+09 0.186308E+11 0.00 0.00
Minimum of Months 0.149610E+09 0.627088E+09 0.918837E+09 0.00 0.918837E+09 0.00 0.00
Maximum of Months 0.450790E+10 0.650383E+10 0.238312E+10 0.157342E+09 0.222578E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_MID_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.103027E+10 0.391609E+10 0.145522E+10 0.656378E+09 0.798842E+09 0.00 0.00
February 0.161036E+10 0.295774E+10 0.165704E+10 0.890313E+09 0.766723E+09 0.00 0.00
March 0.261030E+10 0.216525E+10 0.230811E+10 0.105072E+10 0.125739E+10 0.00 0.00
April 0.371954E+10 0.169471E+10 0.270106E+10 0.123161E+10 0.146945E+10 0.00 0.00
May 0.469276E+10 0.117722E+10 0.306484E+10 0.129607E+10 0.176876E+10 0.00 0.00
June 0.536023E+10 0.723162E+09 0.307078E+10 0.128704E+10 0.178374E+10 0.00 0.00
July 0.558182E+10 0.534844E+09 0.309394E+10 0.130073E+10 0.179320E+10 0.00 0.00
August 0.520088E+10 0.436126E+09 0.282993E+10 0.112273E+10 0.170720E+10 0.00 0.00
September 0.359282E+10 0.944838E+09 0.225079E+10 0.997266E+09 0.125352E+10 0.00 0.00
October 0.254734E+10 0.198028E+10 0.198412E+10 0.103239E+10 0.951733E+09 0.00 0.00
November 0.152046E+10 0.252625E+10 0.153515E+10 0.695109E+09 0.840039E+09 0.00 0.00
December 0.104263E+10 0.324737E+10 0.137406E+10 0.626349E+09 0.747709E+09 0.00 0.00
               
Annual Sum or Average 0.385094E+11 0.223039E+11 0.273250E+11 0.121867E+11 0.151383E+11 0.00 0.00
Minimum of Months 0.103027E+10 0.436126E+09 0.137406E+10 0.626349E+09 0.747709E+09 0.00 0.00
Maximum of Months 0.558182E+10 0.391609E+10 0.309394E+10 0.130073E+10 0.179320E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_MID_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.601786E+10 0.569845E+10 0.531579E+10 0.370615E+10 0.160964E+10 0.00 0.00
February 0.551997E+10 0.447388E+10 0.448128E+10 0.300392E+10 0.147735E+10 0.00 0.00
March 0.595083E+10 0.350271E+10 0.446199E+10 0.232533E+10 0.213666E+10 0.00 0.00
April 0.480896E+10 0.278833E+10 0.323393E+10 0.105271E+10 0.218122E+10 0.00 0.00
May 0.426919E+10 0.188191E+10 0.269998E+10 0.313811E+09 0.238617E+10 0.00 0.00
June 0.455895E+10 0.113229E+10 0.241589E+10 0.134435E+09 0.228145E+10 0.00 0.00
July 0.500361E+10 0.813558E+09 0.252383E+10 0.188191E+09 0.233564E+10 0.00 0.00
August 0.607260E+10 0.688025E+09 0.301327E+10 0.562890E+09 0.245038E+10 0.00 0.00
September 0.548881E+10 0.152145E+10 0.320696E+10 0.119282E+10 0.201414E+10 0.00 0.00
October 0.706881E+10 0.318832E+10 0.480415E+10 0.311213E+10 0.169202E+10 0.00 0.00
November 0.659045E+10 0.401454E+10 0.500168E+10 0.331903E+10 0.168265E+10 0.00 0.00
December 0.630616E+10 0.494341E+10 0.523990E+10 0.368631E+10 0.155359E+10 0.00 0.00
               
Annual Sum or Average 0.676562E+11 0.346469E+11 0.463986E+11 0.225977E+11 0.238009E+11 0.00 0.00
Minimum of Months 0.426919E+10 0.688025E+09 0.241589E+10 0.134435E+09 0.147735E+10 0.00 0.00
Maximum of Months 0.706881E+10 0.569845E+10 0.531579E+10 0.370615E+10 0.245038E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_MID_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.117851E+10 0.419604E+10 0.149471E+10 0.693353E+09 0.801361E+09 0.00 0.00
February 0.158302E+10 0.322817E+10 0.154986E+10 0.724655E+09 0.825209E+09 0.00 0.00
March 0.310165E+10 0.243145E+10 0.252917E+10 0.122215E+10 0.130702E+10 0.00 0.00
April 0.388163E+10 0.192463E+10 0.275349E+10 0.125998E+10 0.149350E+10 0.00 0.00
May 0.445012E+10 0.132909E+10 0.285958E+10 0.108338E+10 0.177620E+10 0.00 0.00
June 0.512100E+10 0.838023E+09 0.291021E+10 0.111955E+10 0.179067E+10 0.00 0.00
July 0.516654E+10 0.617750E+09 0.283650E+10 0.105168E+10 0.178482E+10 0.00 0.00
August 0.511754E+10 0.535012E+09 0.277936E+10 0.103937E+10 0.173999E+10 0.00 0.00
September 0.351474E+10 0.104813E+10 0.219138E+10 0.912804E+09 0.127857E+10 0.00 0.00
October 0.273061E+10 0.222636E+10 0.201733E+10 0.104722E+10 0.970115E+09 0.00 0.00
November 0.173290E+10 0.284713E+10 0.155804E+10 0.699329E+09 0.858712E+09 0.00 0.00
December 0.112625E+10 0.360408E+10 0.132822E+10 0.580965E+09 0.747255E+09 0.00 0.00
               
Annual Sum or Average 0.387045E+11 0.248259E+11 0.268079E+11 0.114344E+11 0.153734E+11 0.00 0.00
Minimum of Months 0.112625E+10 0.535012E+09 0.132822E+10 0.580965E+09 0.747255E+09 0.00 0.00
Maximum of Months 0.516654E+10 0.419604E+10 0.291021E+10 0.125998E+10 0.179067E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_TOP_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.188840E+09 0.602606E+10 0.993954E+09 0.00 0.993954E+09 0.00 0.00
February 0.483931E+09 0.450158E+10 0.995084E+09 0.00 0.995084E+09 0.00 0.00
March 0.116593E+10 0.316413E+10 0.154673E+10 0.00 0.154673E+10 0.00 0.00
April 0.205330E+10 0.251260E+10 0.181056E+10 8030357.15 0.180253E+10 0.00 0.00
May 0.314211E+10 0.173082E+10 0.223758E+10 71411286.64 0.216617E+10 0.00 0.00
June 0.430654E+10 0.107631E+10 0.238312E+10 0.157342E+09 0.222578E+10 0.00 0.00
July 0.443831E+10 0.798775E+09 0.232342E+10 0.112943E+09 0.221048E+10 0.00 0.00
August 0.405441E+10 0.657787E+09 0.206630E+10 22509151.83 0.204380E+10 0.00 0.00
September 0.228489E+10 0.139071E+10 0.151155E+10 212783.61 0.151133E+10 0.00 0.00
October 0.114604E+10 0.286770E+10 0.118759E+10 0.00 0.118759E+10 0.00 0.00
November 0.656804E+09 0.370938E+10 0.102856E+10 0.00 0.102856E+10 0.00 0.00
December 0.210297E+09 0.482670E+10 0.918837E+09 0.00 0.918837E+09 0.00 0.00
               
Annual Sum or Average 0.241314E+11 0.332626E+11 0.190033E+11 0.372449E+09 0.186308E+11 0.00 0.00
Minimum of Months 0.188840E+09 0.657787E+09 0.918837E+09 0.00 0.918837E+09 0.00 0.00
Maximum of Months 0.443831E+10 0.602606E+10 0.238312E+10 0.157342E+09 0.222578E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_TOP_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.109463E+10 0.362043E+10 0.145522E+10 0.656378E+09 0.798842E+09 0.00 0.00
February 0.166514E+10 0.274582E+10 0.165704E+10 0.890313E+09 0.766723E+09 0.00 0.00
March 0.267013E+10 0.201766E+10 0.230811E+10 0.105072E+10 0.125739E+10 0.00 0.00
April 0.373486E+10 0.163684E+10 0.270106E+10 0.123161E+10 0.146945E+10 0.00 0.00
May 0.466712E+10 0.117785E+10 0.306484E+10 0.129607E+10 0.176876E+10 0.00 0.00
June 0.531834E+10 0.742396E+09 0.307078E+10 0.128704E+10 0.178374E+10 0.00 0.00
July 0.553313E+10 0.553908E+09 0.309394E+10 0.130073E+10 0.179320E+10 0.00 0.00
August 0.515330E+10 0.457423E+09 0.282993E+10 0.112273E+10 0.170720E+10 0.00 0.00
September 0.358038E+10 0.928924E+09 0.225079E+10 0.997266E+09 0.125352E+10 0.00 0.00
October 0.259256E+10 0.184183E+10 0.198412E+10 0.103239E+10 0.951733E+09 0.00 0.00
November 0.162282E+10 0.228205E+10 0.153515E+10 0.695109E+09 0.840039E+09 0.00 0.00
December 0.112089E+10 0.290798E+10 0.137406E+10 0.626349E+09 0.747709E+09 0.00 0.00
               
Annual Sum or Average 0.387533E+11 0.209131E+11 0.273250E+11 0.121867E+11 0.151383E+11 0.00 0.00
Minimum of Months 0.109463E+10 0.457423E+09 0.137406E+10 0.626349E+09 0.747709E+09 0.00 0.00
Maximum of Months 0.553313E+10 0.362043E+10 0.309394E+10 0.130073E+10 0.179320E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_TOP_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.617162E+10 0.523711E+10 0.531579E+10 0.370615E+10 0.160964E+10 0.00 0.00
February 0.561935E+10 0.414152E+10 0.448128E+10 0.300392E+10 0.147735E+10 0.00 0.00
March 0.602003E+10 0.327363E+10 0.446199E+10 0.232533E+10 0.213666E+10 0.00 0.00
April 0.482871E+10 0.267788E+10 0.323393E+10 0.105271E+10 0.218122E+10 0.00 0.00
May 0.423724E+10 0.186827E+10 0.269998E+10 0.313811E+09 0.238617E+10 0.00 0.00
June 0.450265E+10 0.115575E+10 0.241589E+10 0.134435E+09 0.228145E+10 0.00 0.00
July 0.493517E+10 0.842167E+09 0.252383E+10 0.188191E+09 0.233564E+10 0.00 0.00
August 0.600553E+10 0.721437E+09 0.301327E+10 0.562890E+09 0.245038E+10 0.00 0.00
September 0.546697E+10 0.149616E+10 0.320696E+10 0.119282E+10 0.201414E+10 0.00 0.00
October 0.711139E+10 0.298167E+10 0.480415E+10 0.311213E+10 0.169202E+10 0.00 0.00
November 0.672061E+10 0.366423E+10 0.500168E+10 0.331903E+10 0.168265E+10 0.00 0.00
December 0.646495E+10 0.444784E+10 0.523990E+10 0.368631E+10 0.155359E+10 0.00 0.00
               
Annual Sum or Average 0.680842E+11 0.325077E+11 0.463986E+11 0.225977E+11 0.238009E+11 0.00 0.00
Minimum of Months 0.423724E+10 0.721437E+09 0.241589E+10 0.134435E+09 0.147735E+10 0.00 0.00
Maximum of Months 0.711139E+10 0.523711E+10 0.531579E+10 0.370615E+10 0.245038E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_TOP_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.122803E+10 0.389120E+10 0.149471E+10 0.693353E+09 0.801361E+09 0.00 0.00
February 0.161724E+10 0.301834E+10 0.154986E+10 0.724655E+09 0.825209E+09 0.00 0.00
March 0.313956E+10 0.227283E+10 0.252917E+10 0.122215E+10 0.130702E+10 0.00 0.00
April 0.389124E+10 0.185343E+10 0.275349E+10 0.125998E+10 0.149350E+10 0.00 0.00
May 0.442793E+10 0.131915E+10 0.285958E+10 0.108338E+10 0.177620E+10 0.00 0.00
June 0.508098E+10 0.848346E+09 0.291021E+10 0.111955E+10 0.179067E+10 0.00 0.00
July 0.512536E+10 0.630142E+09 0.283650E+10 0.105168E+10 0.178482E+10 0.00 0.00
August 0.507631E+10 0.550466E+09 0.277936E+10 0.103937E+10 0.173999E+10 0.00 0.00
September 0.350315E+10 0.102718E+10 0.219138E+10 0.912804E+09 0.127857E+10 0.00 0.00
October 0.275911E+10 0.207745E+10 0.201733E+10 0.104722E+10 0.970115E+09 0.00 0.00
November 0.179601E+10 0.260897E+10 0.155804E+10 0.699329E+09 0.858712E+09 0.00 0.00
December 0.117461E+10 0.328333E+10 0.132822E+10 0.580965E+09 0.747255E+09 0.00 0.00
               
Annual Sum or Average 0.388195E+11 0.233808E+11 0.268079E+11 0.114344E+11 0.153734E+11 0.00 0.00
Minimum of Months 0.117461E+10 0.550466E+09 0.132822E+10 0.580965E+09 0.747255E+09 0.00 0.00
Maximum of Months 0.512536E+10 0.389120E+10 0.291021E+10 0.125998E+10 0.179067E+10 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: GROUNDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: MIDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: TOPFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: DATACENTER_BOT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: DATACENTER_MID_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: DATACENTER_TOP_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: DATACENTER_BASEMENT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AverageOutdoorConditionsMonthly

For: Environment

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] SITE OUTDOOR AIR WETBULB TEMPERATURE [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] SITE WIND SPEED [m/s] SITE SKY TEMPERATURE [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] SITE RAIN STATUS []
January 3.96 1.39 -3.0 4.56 -7.8 48.74 150.20 0.00
February 7.94 4.18 -1.3 5.19 -4.0 51.84 169.20 0.00
March 13.76 8.97 3.80 4.89 2.25 76.95 193.22 0.00
April 17.21 12.54 8.82 3.95 6.45 95.37 211.82 0.00
May 20.84 16.44 13.69 3.50 11.46 117.34 200.00 0.00
June 24.80 19.35 16.45 3.85 15.08 121.81 213.08 0.00
July 26.06 21.68 19.85 3.24 17.64 119.92 194.46 0.00
August 26.55 22.42 20.72 3.39 18.21 115.12 179.15 0.00
September 22.53 18.74 16.82 3.06 13.44 83.74 156.58 0.02
October 16.03 13.02 10.77 4.05 5.85 53.01 190.38 0.00
November 11.94 8.22 4.17 4.16 0.30 52.20 150.38 0.00
December 7.70 4.64 0.26 4.69 -4.1 44.81 142.03 0.00
                 
Annual Sum or Average 16.65 12.68 9.31 4.04 6.29 81.91 179.25 0.00
Minimum of Months 3.96 1.39 -3.0 3.06 -7.8 44.81 142.03 0.00
Maximum of Months 26.55 22.42 20.72 5.19 18.21 121.81 213.08 0.02



Table of Contents

Report: OutdoorConditionsMaximumDryBulbMonthly

For: Environment

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January 21.10 31-JAN-14:00 12.97 6.70 5.70 12.22 200.50 90.50
February 25.00 26-FEB-14:00 12.75 1.70 4.10 8.15 91.50 816.00
March 27.80 30-MAR-13:00 17.87 12.20 5.70 16.30 231.50 710.50
April 28.90 17-APR-14:20 16.56 8.13 2.03 13.35 125.83 887.67
May 30.60 19-MAY-13:00 18.49 11.70 4.60 15.76 140.00 875.50
June 34.40 06-JUN-14:00 22.39 17.20 8.20 22.13 251.00 561.00
July 36.70 08-JUL-14:00 23.91 18.90 2.10 24.66 274.00 567.00
August 35.00 01-AUG-14:00 23.84 19.40 2.60 26.15 306.00 508.00
September 31.70 07-SEP-15:09 23.05 19.60 4.02 22.55 218.67 591.33
October 30.00 10-OCT-15:00 20.56 16.10 3.60 17.57 97.00 561.00
November 24.40 05-NOV-15:00 17.95 14.40 2.10 14.10 117.50 361.50
December 22.80 12-DEC-14:20 16.78 13.33 5.20 13.35 144.17 433.83
                 
Annual Sum or Average                
Minimum of Months 21.10   12.75 1.70 2.03 8.15 91.50 90.50
Maximum of Months 36.70   23.91 19.60 8.20 26.15 306.00 887.67



Table of Contents

Report: OutdoorConditionsMinimumDryBulbMonthly

For: Environment

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January -6.7 14-JAN-06:10 -7.8 -10.6 4.95 -24.7 0.00 0.00
February -12.8 12-FEB-06:00 -13.8 -18.3 7.20 -30.1 0.00 0.00
March 1.10 19-MAR-06:00 -1.5 -6.1 0.00 -16.2 17.00 290.50
April 0.00 06-APR-04:00 -1.1 -2.8 3.10 -16.5 0.00 0.00
May 7.80 11-MAY-05:00 5.45 2.80 4.10 -7.8 21.50 204.50
June 11.10 10-JUN-04:00 8.73 6.70 0.00 -2.5 0.00 0.00
July 17.20 28-JUL-22:00 16.88 16.70 4.10 14.28 0.00 0.00
August 18.30 25-AUG-05:00 17.20 16.70 3.60 5.13 0.00 0.00
September 11.70 29-SEP-03:00 11.07 10.60 2.60 -2.3 0.00 0.00
October 2.20 26-OCT-04:00 1.95 1.70 3.10 -13.4 0.00 0.00
November -3.3 22-NOV-05:00 -4.0 -5.6 5.20 -20.2 0.00 0.00
December -5.6 18-DEC-07:00 -7.3 -11.7 2.60 -22.7 17.00 320.50
                 
Annual Sum or Average                
Minimum of Months -12.8   -13.8 -18.3 0.00 -30.1 0.00 0.00
Maximum of Months 18.30   17.20 16.70 7.20 14.28 21.50 320.50



Table of Contents

Report: OutdoorConditionsMaximumWetBulbMonthly

For: Environment

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January 16.51 19-JAN-21:00 18.30 15.60 8.80 15.21 0.00 0.00
February 15.81 18-FEB-15:00 17.20 15.00 5.20 13.91 73.00 1.00
March 18.16 30-MAR-12:30 25.85 13.85 5.45 15.39 323.00 600.00
April 20.01 04-APR-13:00 25.00 17.80 9.30 18.64 307.00 197.50
May 22.34 30-MAY-17:00 27.80 20.00 4.10 21.96 97.50 79.50
June 24.32 23-JUN-11:39 31.13 21.87 4.83 22.98 338.17 565.17
July 25.06 07-JUL-11:00 33.30 22.20 3.60 20.75 116.50 900.00
August 25.13 19-AUG-16:00 30.00 23.30 3.10 23.66 197.00 136.50
September 24.10 09-SEP-10:00 30.60 21.70 2.60 21.27 236.00 482.00
October 23.20 18-OCT-15:00 25.60 22.20 5.70 23.82 159.00 2.00
November 18.88 19-NOV-14:00 24.40 16.10 8.20 13.91 143.00 384.50
December 17.57 13-DEC-10:00 19.40 16.70 4.60 14.47 227.50 77.00
                 
Annual Sum or Average                
Minimum of Months 15.81   17.20 13.85 2.60 13.91 0.00 0.00
Maximum of Months 25.13   33.30 23.30 9.30 23.82 338.17 900.00



Table of Contents

Report: OutdoorConditionsMaximumDewPointMonthly

For: Environment

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January 15.60 19-JAN-17:00 17.20 16.13 6.70 14.10 0.00 0.00
February 15.00 18-FEB-16:19 17.20 15.81 5.53 13.91 50.33 1.00
March 16.10 31-MAR-10:00 21.70 18.06 13.90 18.64 268.00 8.00
April 17.80 04-APR-09:20 20.77 18.74 7.53 16.79 242.00 111.50
May 20.60 30-MAY-19:00 25.00 21.79 2.60 12.41 0.00 0.00
June 22.80 18-JUN-16:00 28.30 24.23 0.00 24.66 140.50 115.50
July 23.30 26-JUL-09:00 26.10 24.10 3.60 24.66 338.00 251.50
August 23.90 08-AUG-19:00 26.10 24.51 1.50 24.83 0.00 0.00
September 23.30 16-SEP-16:00 25.60 23.89 2.10 22.13 108.00 57.50
October 22.20 18-OCT-14:00 25.00 23.04 4.60 23.32 234.50 2.00
November 17.20 04-NOV-13:00 17.80 17.48 3.60 15.02 276.50 2.50
December 16.70 13-DEC-16:19 17.03 16.82 2.93 14.10 54.00 4.50
                 
Annual Sum or Average                
Minimum of Months 15.00   17.03 15.81 0.00 12.41 0.00 0.00
Maximum of Months 23.90   28.30 24.51 13.90 24.83 338.00 251.50



Table of Contents

Report: OutdoorGroundConditionsMonthly

For: Environment

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE GROUND TEMPERATURE [C] SITE SURFACE GROUND TEMPERATURE [C] SITE DEEP GROUND TEMPERATURE [C] SITE MAINS WATER TEMPERATURE [C] SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] SITE SNOW ON GROUND STATUS []
January 18.00 13.00 16.00 13.74 22.89 0.00
February 18.00 13.00 16.00 13.65 27.55 0.00
March 18.00 13.00 16.00 15.17 38.46 0.00
April 18.00 13.00 16.00 17.98 47.59 0.00
May 18.00 13.00 16.00 21.32 52.44 0.00
June 18.00 13.00 16.00 24.28 55.84 0.00
July 18.00 13.00 16.00 26.07 52.33 0.00
August 18.00 13.00 16.00 26.20 48.31 0.00
September 18.00 13.00 16.00 24.63 36.35 0.00
October 18.00 13.00 16.00 21.78 31.91 0.00
November 18.00 13.00 16.00 18.45 24.33 0.00
December 18.00 13.00 16.00 15.51 20.76 0.00
             
Annual Sum or Average 18.00 13.00 16.00 19.94 38.29 0.00
Minimum of Months 18.00 13.00 16.00 13.65 20.76 0.00
Maximum of Months 18.00 13.00 16.00 26.20 55.84 0.00



Table of Contents

Report: WaterHeaterReportMonthly

For: SWHSYS1 WATER HEATER

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] WATER HEATER BURNER HEATING ENERGY [] WATER HEATER GAS CONSUMPTION [] WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] WATER HEATER LOSS DEMAND ENERGY [] WATER HEATER HEAT LOSS ENERGY [J] WATER HEATER TANK TEMPERATURE [C] WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] WATER HEATER SOURCE ENERGY []
January 0.370520E+11 -0.360220E+11 0.00 0.00 744.00 0.00 -0.102996E+10 58.97 0.00 0.00
February 0.337321E+11 -0.328030E+11 0.00 0.00 672.00 0.00 -929103846.0 58.98 0.00 0.00
March 0.383089E+11 -0.372808E+11 0.00 0.00 744.00 0.00 -0.102814E+10 58.97 0.00 0.00
April 0.326409E+11 -0.316482E+11 0.00 0.00 720.00 0.00 -992688444.6 58.97 0.00 0.00
May 0.321099E+11 -0.310846E+11 0.00 0.00 744.00 0.00 -0.102528E+10 58.98 0.00 0.00
June 0.293462E+11 -0.283546E+11 0.00 0.00 720.00 0.00 -991548297.6 58.97 0.00 0.00
July 0.265865E+11 -0.255677E+11 0.00 0.00 744.00 0.00 -0.101879E+10 58.98 0.00 0.00
August 0.289265E+11 -0.279038E+11 0.00 0.00 744.00 0.00 -0.102266E+10 58.98 0.00 0.00
September 0.275321E+11 -0.265455E+11 0.00 0.00 720.00 0.00 -986592798.7 58.97 0.00 0.00
October 0.306573E+11 -0.296387E+11 0.00 0.00 744.00 0.00 -0.101865E+10 58.97 0.00 0.00
November 0.326499E+11 -0.316639E+11 0.00 0.00 720.00 0.00 -985997403.1 58.97 0.00 0.00
December 0.348010E+11 -0.337800E+11 0.00 0.00 744.00 0.00 -0.102099E+10 58.97 0.00 0.00
                     
Annual Sum or Average 0.384343E+12 -0.372293E+12 0.00 0.00 8760.00 0.00 -0.120504E+11 58.97 0.00 0.00
Minimum of Months 0.265865E+11 -0.372808E+11 0.00 0.00 672.00 0.00 -0.102996E+10 58.97 0.00 0.00
Maximum of Months 0.383089E+11 -0.255677E+11 0.00 0.00 744.00 0.00 -929103846.0 58.98 0.00 0.00



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_BOT_ZN_1_DAYLCTRL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 290.67 0.50 0.48 01-JAN-09:20 5135.26 32.94 258.50 264.50 1312.65 25.39 169.67 238.83
February 263.00 0.52 0.48 01-FEB-13:39 6070.35 32.98 229.00 235.83 860.67 20.49 86.33 208.17
March 351.67 0.52 0.48 01-MAR-08:00 1281.08 16.72 6.67 303.17 727.60 19.52 81.67 261.67
April 369.33 0.52 0.48 01-APR-09:00 1065.79 16.18 0.00 307.83 595.38 19.06 43.33 256.83
May 407.00 0.52 0.48 01-MAY-07:00 969.25 16.28 0.00 340.33 533.72 19.18 14.33 284.17
June 411.67 0.52 0.48 01-JUN-07:19 900.25 15.97 0.00 342.33 502.31 18.89 5.67 280.67
July 411.00 0.52 0.48 01-JUL-08:09 949.53 16.18 0.00 343.83 522.58 19.06 19.17 282.67
August 390.50 0.52 0.48 01-AUG-07:40 1160.38 16.90 0.00 337.17 623.04 19.77 73.67 287.50
September 298.50 0.52 0.48 01-SEP-07:49 1232.52 17.09 6.50 294.50 674.77 19.66 68.83 239.33
October 293.50 0.51 0.48 01-OCT-10:39 2333.42 22.85 116.50 283.83 793.20 18.88 57.83 232.67
November 299.00 0.51 0.48 01-NOV-08:30 5037.34 32.73 268.00 263.67 888.30 22.15 116.17 233.83
December 285.17 0.50 0.48 01-DEC-07:00 4771.83 32.10 248.33 255.67 1256.60 26.37 168.67 233.00
                         
Annual Sum or Average 4071.00 0.52     2324.11 21.44 1133.50 3572.67 742.80 20.48 905.33 3039.33
Minimum of Months 263.00 0.50 0.48   900.25 15.97 0.00 235.83 502.31 18.88 5.67 208.17
Maximum of Months 411.67 0.52 0.48   6070.35 32.98 268.00 343.83 1312.65 26.37 169.67 287.50



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_BOT_ZN_2_DAYLCTRL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 290.67 0.54 0.48 01-JAN-09:20 1150.59 18.53 70.33 215.50 567.26 19.86 65.00 138.17
February 263.00 0.55 0.48 01-FEB-13:39 1547.56 18.45 60.17 198.17 769.54 19.80 45.50 144.50
March 351.67 0.52 0.48 01-MAR-08:50 1758.97 18.35 79.50 286.00 688.23 20.27 63.33 231.50
April 369.33 0.52 0.48 01-APR-08:09 1720.30 18.18 74.00 305.83 929.61 21.42 83.83 255.33
May 407.00 0.51 0.48 01-MAY-07:19 1945.92 18.58 82.67 348.00 789.72 20.59 76.33 292.17
June 411.67 0.52 0.48 01-JUN-06:40 2057.22 19.88 109.50 350.83 800.40 20.53 79.00 298.33
July 411.00 0.52 0.48 01-JUL-06:10 1946.81 18.50 76.83 354.50 809.76 20.70 78.17 303.33
August 390.50 0.52 0.48 01-AUG-06:40 1800.03 19.00 83.50 335.17 945.55 22.06 95.17 285.33
September 298.50 0.53 0.48 01-SEP-07:19 1702.25 18.99 67.33 286.33 854.92 20.75 57.00 223.50
October 293.50 0.54 0.48 01-OCT-10:39 2100.80 20.23 90.50 240.50 728.49 20.01 58.50 172.50
November 299.00 0.54 0.48 01-NOV-08:20 1350.97 18.75 77.67 224.67 746.19 21.76 78.50 160.83
December 285.17 0.54 0.48 01-DEC-07:00 1182.96 19.09 72.33 212.67 589.97 20.39 53.50 140.83
                         
Annual Sum or Average 4071.00 0.53     1720.29 18.87 944.33 3358.17 777.69 20.72 833.83 2646.33
Minimum of Months 263.00 0.51 0.48   1150.59 18.18 60.17 198.17 567.26 19.80 45.50 138.17
Maximum of Months 411.67 0.55 0.48   2100.80 20.23 109.50 354.50 945.55 22.06 95.17 303.33



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_BOT_ZN_3_DAYLCTRL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 290.67 0.59 0.48 01-JAN-11:30 394.64 12.24 0.00 154.67 238.41 15.46 0.00 22.67
February 263.00 0.58 0.48 01-FEB-13:00 418.16 12.39 0.00 144.50 260.32 15.57 0.00 56.83
March 351.67 0.54 0.48 01-MAR-12:30 534.33 14.25 0.00 272.50 325.77 17.27 0.00 147.33
April 369.33 0.52 0.48 01-APR-10:39 640.11 15.25 0.00 308.33 382.25 18.13 0.00 222.33
May 407.00 0.50 0.48 01-MAY-07:49 792.30 16.43 1.17 365.33 467.79 21.26 51.83 317.83
June 411.67 0.50 0.48 01-JUN-06:00 865.26 18.17 37.00 376.00 502.46 20.88 41.00 339.83
July 411.00 0.51 0.48 01-JUL-06:30 878.77 17.80 27.33 373.83 488.83 20.52 29.50 328.17
August 390.50 0.51 0.48 01-AUG-07:19 781.93 16.34 0.00 349.67 454.17 19.18 0.00 290.50
September 298.50 0.53 0.48 01-SEP-07:00 591.65 14.99 0.00 282.17 358.67 17.88 0.00 161.83
October 293.50 0.57 0.48 01-OCT-10:50 435.87 12.83 0.00 181.67 280.35 16.05 0.00 74.83
November 299.00 0.58 0.48 01-NOV-10:09 407.13 12.56 0.00 185.33 247.91 15.70 0.00 23.50
December 285.17 0.59 0.48 01-DEC-10:39 380.11 12.29 0.00 147.33 230.80 15.56 0.00 2.50
                         
Annual Sum or Average 4071.00 0.54     621.19 14.94 65.50 3141.33 368.04 18.11 122.33 1988.17
Minimum of Months 263.00 0.50 0.48   380.11 12.24 0.00 144.50 230.80 15.46 0.00 2.50
Maximum of Months 411.67 0.59 0.48   878.77 18.17 37.00 376.00 502.46 21.26 51.83 339.83



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_BOT_ZN_4_DAYLCTRL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 290.67 0.54 0.48 01-JAN-11:09 1355.63 18.69 69.67 217.17 781.20 21.78 74.83 147.50
February 263.00 0.55 0.48 01-FEB-13:39 1344.91 18.47 63.67 185.00 674.52 19.87 67.83 137.33
March 351.67 0.52 0.48 01-MAR-11:00 1775.01 18.93 77.50 288.67 948.45 22.01 86.00 230.83
April 369.33 0.52 0.48 01-APR-10:39 1860.99 18.38 78.17 307.83 1056.72 20.37 63.50 259.67
May 407.00 0.52 0.48 01-MAY-08:50 1954.43 16.90 50.33 345.83 778.65 18.61 26.50 294.33
June 411.67 0.52 0.48 01-JUN-08:09 2044.68 14.77 1.67 350.17 838.62 18.56 30.50 300.33
July 411.00 0.52 0.48 01-JUL-08:30 2030.64 16.86 51.67 349.17 818.61 18.59 34.50 297.00
August 390.50 0.51 0.48 01-AUG-08:20 1988.68 19.07 86.50 338.33 819.73 19.28 57.17 289.67
September 298.50 0.52 0.48 01-SEP-09:09 1741.64 19.39 74.17 285.50 917.00 22.45 85.17 218.00
October 293.50 0.54 0.48 01-OCT-10:50 1840.40 18.46 72.33 231.67 701.56 20.07 59.00 172.83
November 299.00 0.54 0.48 01-NOV-10:09 1313.70 18.98 80.83 226.00 652.50 20.40 64.00 162.00
December 285.17 0.54 0.48 01-DEC-10:30 1143.04 18.80 72.83 209.67 577.15 20.23 58.50 139.00
                         
Annual Sum or Average 4071.00 0.53     1740.71 18.01 779.33 3335.00 807.25 20.06 707.50 2648.50
Minimum of Months 263.00 0.51 0.48   1143.04 14.77 1.67 185.00 577.15 18.56 26.50 137.33
Maximum of Months 411.67 0.55 0.48   2044.68 19.39 86.50 350.17 1056.72 22.45 86.00 300.33



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_MID_ZN_1_DAYLCTRL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 290.67 0.51 0.48 01-JAN-09:20 5045.08 30.47 233.00 259.83 1347.48 21.60 100.50 240.17
February 263.00 0.52 0.48 01-FEB-13:39 6053.42 32.50 227.50 234.00 895.79 15.72 25.83 208.67
March 351.67 0.52 0.48 01-MAR-08:00 1263.71 10.58 6.50 302.33 755.03 15.21 0.00 264.33
April 369.33 0.52 0.48 01-APR-09:50 1048.79 10.33 0.00 306.67 615.77 15.14 0.00 259.33
May 407.00 0.52 0.48 01-MAY-07:49 950.46 10.60 0.00 338.17 549.68 15.36 0.00 287.67
June 411.67 0.52 0.48 01-JUN-07:19 882.89 10.44 0.00 340.50 517.04 15.16 0.00 283.67
July 411.00 0.53 0.48 01-JUL-07:00 930.38 10.63 0.00 342.00 537.66 15.32 0.00 286.67
August 390.50 0.52 0.48 01-AUG-07:40 1135.99 11.29 0.00 335.17 641.03 15.98 0.00 290.33
September 298.50 0.52 0.48 01-SEP-07:49 1210.33 11.47 6.50 293.33 696.93 15.79 0.00 242.83
October 293.50 0.51 0.48 01-OCT-10:39 2321.95 18.72 115.00 281.33 832.05 14.36 2.00 236.00
November 299.00 0.51 0.48 01-NOV-08:30 5016.18 32.05 266.33 262.83 943.91 19.77 79.33 241.00
December 285.17 0.50 0.48 01-DEC-08:09 4747.47 31.25 241.33 254.67 1246.24 21.07 97.50 228.17
                         
Annual Sum or Average 4071.00 0.52     2299.92 17.13 1096.17 3550.83 765.89 16.51 305.17 3068.83
Minimum of Months 263.00 0.50 0.48   882.89 10.33 0.00 234.00 517.04 14.36 0.00 208.67
Maximum of Months 411.67 0.53 0.48   6053.42 32.50 266.33 342.00 1347.48 21.60 100.50 290.33



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_MID_ZN_2_DAYLCTRL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 290.67 0.54 0.48 01-JAN-09:20 1009.75 13.47 45.33 213.33 582.50 17.69 44.67 144.33
February 263.00 0.55 0.48 01-FEB-13:39 1552.29 15.46 59.50 198.00 790.91 17.38 37.33 149.67
March 351.67 0.52 0.48 01-MAR-08:39 1763.32 15.21 78.00 284.83 709.62 17.77 47.00 236.83
April 369.33 0.52 0.48 01-APR-08:09 1718.65 14.86 73.00 305.50 953.59 18.99 66.50 259.67
May 407.00 0.51 0.48 01-MAY-07:19 1930.85 15.11 79.83 347.17 815.20 17.89 49.17 298.67
June 411.67 0.52 0.48 01-JUN-06:30 1949.25 15.05 82.17 349.50 825.67 17.86 51.67 301.83
July 411.00 0.52 0.48 01-JUL-06:10 1931.72 15.12 76.17 353.50 834.79 18.03 51.17 307.50
August 390.50 0.52 0.48 01-AUG-06:40 1784.64 15.76 83.00 334.33 968.44 19.70 71.67 288.83
September 298.50 0.53 0.48 01-SEP-07:19 1705.07 15.75 65.83 285.00 878.49 18.26 43.83 227.83
October 293.50 0.53 0.48 01-OCT-10:39 1933.03 15.13 68.17 241.00 751.26 17.57 42.67 177.67
November 299.00 0.54 0.48 01-NOV-08:20 1348.79 15.94 77.00 224.33 762.09 19.82 69.83 167.50
December 285.17 0.54 0.48 01-DEC-07:00 1169.58 15.93 68.00 211.50 605.57 18.26 47.17 145.50
                         
Annual Sum or Average 4071.00 0.53     1682.35 15.22 856.00 3348.00 799.63 18.29 622.67 2705.83
Minimum of Months 263.00 0.51 0.48   1009.75 13.47 45.33 198.00 582.50 17.38 37.33 144.33
Maximum of Months 411.67 0.55 0.48   1949.25 15.94 83.00 353.50 968.44 19.82 71.67 307.50



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_MID_ZN_3_DAYLCTRL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 290.67 0.58 0.48 01-JAN-11:30 387.32 6.40 0.00 151.83 245.31 11.43 0.00 27.50
February 263.00 0.58 0.48 01-FEB-13:00 411.46 6.79 0.00 142.33 268.29 11.74 0.00 65.50
March 351.67 0.54 0.48 01-MAR-12:20 525.69 8.91 0.00 269.33 335.69 13.83 0.00 165.00
April 369.33 0.52 0.48 01-APR-10:39 630.18 9.95 0.00 307.00 394.14 14.83 0.00 229.67
May 407.00 0.50 0.48 01-MAY-07:49 778.83 10.91 1.17 364.17 481.55 18.38 52.33 323.33
June 411.67 0.50 0.48 01-JUN-06:49 850.86 13.15 36.67 375.33 524.92 19.23 67.33 349.83
July 411.00 0.51 0.48 01-JUL-06:19 863.87 12.74 27.00 372.67 502.95 17.30 27.67 331.50
August 390.50 0.51 0.48 01-AUG-07:10 764.99 11.10 0.00 346.17 467.03 15.88 0.00 296.17
September 298.50 0.53 0.48 01-SEP-07:00 581.54 9.97 0.00 280.17 369.13 14.76 0.00 170.17
October 293.50 0.57 0.48 01-OCT-10:50 429.84 7.46 0.00 181.33 289.21 12.56 0.00 81.67
November 299.00 0.58 0.48 01-NOV-10:09 399.32 6.93 0.00 181.50 254.89 11.84 0.00 33.17
December 285.17 0.59 0.48 01-DEC-10:30 372.42 6.39 0.00 144.00 237.17 11.49 0.00 8.33
                         
Annual Sum or Average 4071.00 0.54     610.36 9.56 64.83 3115.83 379.65 14.83 147.33 2081.83
Minimum of Months 263.00 0.50 0.48   372.42 6.39 0.00 142.33 237.17 11.43 0.00 8.33
Maximum of Months 411.67 0.59 0.48   863.87 13.15 36.67 375.33 524.92 19.23 67.33 349.83



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_MID_ZN_4_DAYLCTRL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 290.67 0.54 0.48 01-JAN-11:09 1354.76 15.74 68.00 216.67 797.92 19.83 65.83 152.83
February 263.00 0.55 0.48 01-FEB-13:39 1186.53 13.00 42.17 185.00 694.20 17.50 39.67 140.00
March 351.67 0.52 0.48 01-MAR-11:50 1780.49 15.70 76.33 288.00 910.80 18.10 51.00 233.67
April 369.33 0.52 0.48 01-APR-10:39 1859.15 15.08 76.83 307.50 1080.68 17.74 50.67 264.17
May 407.00 0.52 0.48 01-MAY-08:39 1848.58 13.09 49.67 344.83 802.13 15.42 0.00 299.00
June 411.67 0.52 0.48 01-JUN-07:00 2031.51 10.40 1.67 349.67 842.29 15.38 0.00 301.17
July 411.00 0.52 0.48 01-JUL-08:20 2006.01 13.14 51.33 348.67 825.82 15.42 0.00 299.17
August 390.50 0.51 0.48 01-AUG-08:20 1896.20 15.84 86.50 337.33 842.74 16.24 7.67 294.50
September 298.50 0.52 0.48 01-SEP-09:09 1745.67 16.35 74.17 284.83 940.03 20.19 62.67 223.67
October 293.50 0.54 0.48 01-OCT-10:50 1844.44 15.39 71.83 232.17 723.30 17.60 41.50 179.33
November 299.00 0.54 0.48 01-NOV-10:09 1311.61 16.16 80.33 225.67 668.62 18.19 52.17 167.33
December 285.17 0.54 0.48 01-DEC-10:20 1141.42 16.00 71.00 209.50 592.21 18.11 46.83 142.67
                         
Annual Sum or Average 4071.00 0.53     1707.77 14.51 749.83 3329.83 819.78 17.28 418.00 2697.50
Minimum of Months 263.00 0.51 0.48   1141.42 10.40 1.67 185.00 592.21 15.38 0.00 140.00
Maximum of Months 411.67 0.55 0.48   2031.51 16.35 86.50 349.67 1080.68 20.19 65.83 301.17



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_TOP_ZN_1_DAYLCTRL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 290.67 0.51 0.48 01-JAN-09:20 5044.69 30.46 233.00 259.83 1348.41 21.59 100.50 240.17
February 263.00 0.52 0.48 01-FEB-13:39 6018.43 31.23 217.00 230.17 896.64 15.70 25.83 208.67
March 351.67 0.52 0.48 01-MAR-08:00 1264.30 10.53 6.33 302.33 755.88 15.19 0.00 264.33
April 369.33 0.52 0.48 01-APR-09:50 1049.35 10.29 0.00 306.67 616.47 15.12 0.00 259.67
May 407.00 0.52 0.48 01-MAY-07:49 950.94 10.56 0.00 338.17 550.31 15.34 0.00 287.83
June 411.67 0.52 0.48 01-JUN-07:19 883.29 10.40 0.00 340.50 517.61 15.14 0.00 284.00
July 411.00 0.53 0.48 01-JUL-07:00 930.84 10.59 0.00 342.00 538.26 15.30 0.00 287.00
August 390.50 0.52 0.48 01-AUG-07:40 1136.63 11.25 0.00 335.17 641.82 15.96 0.00 290.33
September 298.50 0.52 0.48 01-SEP-07:49 1210.97 11.43 6.50 293.33 697.76 15.78 0.00 242.83
October 293.50 0.51 0.48 01-OCT-10:39 2322.34 18.69 115.00 281.33 832.83 14.34 2.00 236.33
November 299.00 0.51 0.48 01-NOV-08:30 5016.03 32.04 266.33 262.83 944.86 19.76 79.33 241.00
December 285.17 0.50 0.48 01-DEC-08:09 4746.91 31.24 241.17 254.67 1247.16 21.06 97.50 228.17
                         
Annual Sum or Average 4071.00 0.52     2297.95 17.02 1085.33 3547.00 766.65 16.50 305.17 3070.33
Minimum of Months 263.00 0.50 0.48   883.29 10.29 0.00 230.17 517.61 14.34 0.00 208.67
Maximum of Months 411.67 0.53 0.48   6018.43 32.04 266.33 342.00 1348.41 21.59 100.50 290.33



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_TOP_ZN_2_DAYLCTRL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 290.67 0.54 0.48 01-JAN-09:20 1009.65 13.42 45.33 213.33 582.94 17.67 44.67 144.83
February 263.00 0.55 0.48 01-FEB-13:39 1552.17 15.42 59.50 197.83 791.31 17.36 37.33 150.00
March 351.67 0.52 0.48 01-MAR-08:39 1763.27 15.17 78.00 284.83 710.18 17.75 47.00 236.83
April 369.33 0.52 0.48 01-APR-08:09 1718.74 14.82 73.00 305.50 954.22 18.97 66.50 259.83
May 407.00 0.51 0.48 01-MAY-07:19 1930.98 15.06 79.83 347.33 815.93 17.87 49.17 298.67
June 411.67 0.52 0.48 01-JUN-06:30 1949.34 15.01 82.17 349.33 826.41 17.84 51.67 301.83
July 411.00 0.52 0.48 01-JUL-06:10 1931.79 15.08 76.17 353.50 835.55 18.01 51.17 307.50
August 390.50 0.52 0.48 01-AUG-06:40 1784.78 15.72 83.00 334.33 969.22 19.68 71.67 289.17
September 298.50 0.53 0.48 01-SEP-07:19 1704.94 15.71 65.83 285.00 879.10 18.24 43.83 228.00
October 293.50 0.53 0.48 01-OCT-10:39 1932.81 15.09 68.17 241.00 751.69 17.55 42.67 177.83
November 299.00 0.54 0.48 01-NOV-08:20 1348.65 15.90 76.83 224.33 762.53 19.81 69.83 167.67
December 285.17 0.54 0.48 01-DEC-07:00 1169.44 15.89 68.00 211.50 605.97 18.24 47.17 145.67
                         
Annual Sum or Average 4071.00 0.53     1682.34 15.19 855.83 3347.83 800.23 18.27 622.67 2707.83
Minimum of Months 263.00 0.51 0.48   1009.65 13.42 45.33 197.83 582.94 17.36 37.33 144.83
Maximum of Months 411.67 0.55 0.48   1949.34 15.90 83.00 353.50 969.22 19.81 71.67 307.50



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_TOP_ZN_3_DAYLCTRL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 290.67 0.58 0.48 01-JAN-11:30 387.32 6.36 0.00 151.50 245.53 11.41 0.00 27.67
February 263.00 0.58 0.48 01-FEB-13:00 411.42 6.75 0.00 142.33 268.51 11.72 0.00 65.67
March 351.67 0.54 0.48 01-MAR-12:20 525.68 8.87 0.00 269.50 335.98 13.81 0.00 165.50
April 369.33 0.52 0.48 01-APR-10:39 630.24 9.91 0.00 307.00 394.51 14.81 0.00 229.67
May 407.00 0.50 0.48 01-MAY-07:49 778.97 10.87 1.17 364.17 482.03 18.37 52.33 323.67
June 411.67 0.50 0.48 01-JUN-06:49 851.03 13.11 36.67 375.33 525.44 19.21 67.33 349.83
July 411.00 0.51 0.48 01-JUL-06:19 864.03 12.70 27.00 372.67 503.46 17.28 27.67 331.50
August 390.50 0.51 0.48 01-AUG-07:10 765.08 11.06 0.00 346.33 467.50 15.87 0.00 296.33
September 298.50 0.53 0.48 01-SEP-07:00 581.51 9.93 0.00 280.00 369.45 14.74 0.00 170.33
October 293.50 0.57 0.48 01-OCT-10:50 429.76 7.42 0.00 181.50 289.42 12.54 0.00 81.67
November 299.00 0.58 0.48 01-NOV-10:09 399.29 6.89 0.00 181.50 255.12 11.82 0.00 33.17
December 285.17 0.59 0.48 01-DEC-10:30 372.39 6.34 0.00 143.67 237.38 11.47 0.00 8.33
                         
Annual Sum or Average 4071.00 0.54     610.41 9.52 64.83 3115.50 380.01 14.81 147.33 2083.33
Minimum of Months 263.00 0.50 0.48   372.39 6.34 0.00 142.33 237.38 11.41 0.00 8.33
Maximum of Months 411.67 0.59 0.48   864.03 13.11 36.67 375.33 525.44 19.21 67.33 349.83



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_TOP_ZN_4_DAYLCTRL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 290.67 0.54 0.48 01-JAN-11:09 1354.66 15.70 68.00 216.67 798.35 19.82 65.83 153.00
February 263.00 0.55 0.48 01-FEB-13:39 1186.37 12.96 42.17 185.00 694.68 17.48 39.67 140.00
March 351.67 0.52 0.48 01-MAR-11:50 1780.28 15.66 76.33 288.00 911.38 18.09 51.00 234.00
April 369.33 0.52 0.48 01-APR-10:39 1859.22 15.04 76.83 307.67 1081.34 17.72 50.67 264.33
May 407.00 0.52 0.48 01-MAY-08:39 1848.72 13.05 49.67 344.83 802.88 15.40 0.00 299.00
June 411.67 0.52 0.48 01-JUN-07:00 2031.61 10.35 1.67 349.67 843.04 15.36 0.00 301.33
July 411.00 0.52 0.48 01-JUL-08:20 2006.15 13.10 51.33 348.67 826.58 15.40 0.00 299.33
August 390.50 0.51 0.48 01-AUG-08:20 1896.36 15.80 86.50 337.33 839.50 16.05 5.33 294.50
September 298.50 0.52 0.48 01-SEP-09:09 1745.68 16.31 74.17 284.83 898.59 18.55 47.00 221.17
October 293.50 0.54 0.48 01-OCT-10:50 1844.23 15.35 71.83 232.17 723.76 17.59 41.50 179.33
November 299.00 0.54 0.48 01-NOV-10:09 1311.47 16.12 80.33 225.67 669.08 18.18 52.17 167.33
December 285.17 0.54 0.48 01-DEC-10:20 1141.29 15.97 71.00 209.17 592.62 18.09 46.83 143.17
                         
Annual Sum or Average 4071.00 0.53     1707.76 14.47 749.83 3329.67 816.93 17.13 400.00 2696.50
Minimum of Months 263.00 0.51 0.48   1141.29 10.35 1.67 185.00 592.62 15.36 0.00 140.00
Maximum of Months 411.67 0.55 0.48   2031.61 16.31 86.50 349.67 1081.34 19.82 65.83 301.33



Table of Contents

Report: CoilReportMonthly

For: VAV_BOT WITH REHEAT HEATING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.264833E+09 25260.46 06-JAN-07:10 0.00 0.00 0.00 0.00 0.00
February 0.216253E+09 32980.51 03-FEB-07:10 0.00 0.00 0.00 0.00 0.00
March 40577782.93 9970.30 18-MAR-06:10 0.00 0.00 0.00 0.00 0.00
April 0.148729E+09 15043.43 12-APR-15:40 0.00 0.00 0.00 0.00 0.00
May 0.186207E+09 11916.30 15-MAY-16:05 0.00 0.00 0.00 0.00 0.00
June 23895325.41 6149.54 02-JUN-14:00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 10137995.85 4808.95 25-AUG-11:20 0.00 0.00 0.00 0.00 0.00
September 34894515.19 8344.88 14-SEP-16:20 0.00 0.00 0.00 0.00 0.00
October 12625255.81 11066.23 26-OCT-06:10 0.00 0.00 0.00 0.00 0.00
November 71253101.54 21700.96 22-NOV-07:10 0.00 0.00 0.00 0.00 0.00
December 0.192232E+09 24741.22 18-DEC-07:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.120164E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.264833E+09 32980.51   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: CORE_BOTTOM VAV BOX REHEAT COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.393014E+09 12475.63 14-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 0.123612E+09 12508.42 03-FEB-06:01 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 694654.38 270.03 22-NOV-06:50 0.00 0.00 0.00 0.00 0.00
December 1164563.63 252.26 18-DEC-06:50 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.518486E+09     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.393014E+09 12508.42   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.268701E+09 10253.03 14-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 80168276.54 10280.94 03-FEB-06:01 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 2726077.59 1002.43 22-NOV-06:03 0.00 0.00 0.00 0.00 0.00
December 16768872.51 1867.30 01-DEC-06:03 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.368364E+09     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.268701E+09 10280.94   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.401918E+09 14611.66 14-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 0.136827E+09 14650.03 03-FEB-06:01 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 3678691.41 1007.87 22-NOV-06:06 0.00 0.00 0.00 0.00 0.00
December 26321388.48 9496.10 26-DEC-06:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.568745E+09     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.401918E+09 14650.03   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 59353899.57 8448.36 09-JAN-06:02 0.00 0.00 0.00 0.00 0.00
February 559780.59 195.37 13-FEB-06:50 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 59913680.16     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 59353899.57 8448.36   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: VAV_MID WITH REHEAT HEATING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.707458E+10 281022.76 09-JAN-07:10 0.00 0.00 0.00 0.00 0.00
February 0.496576E+10 351225.42 03-FEB-07:10 0.00 0.00 0.00 0.00 0.00
March 0.826116E+09 117984.76 18-MAR-06:10 0.00 0.00 0.00 0.00 0.00
April 0.112329E+10 145097.38 06-APR-06:10 0.00 0.00 0.00 0.00 0.00
May 0.138596E+10 100801.35 15-MAY-14:40 0.00 0.00 0.00 0.00 0.00
June 0.590359E+09 60646.39 02-JUN-14:20 0.00 0.00 0.00 0.00 0.00
July 5074.21 8.46 26-JUL-10:10 0.00 0.00 0.00 0.00 0.00
August 72894317.12 60482.17 25-AUG-11:20 0.00 0.00 0.00 0.00 0.00
September 0.250679E+09 38061.31 15-SEP-11:40 0.00 0.00 0.00 0.00 0.00
October 0.406503E+09 131366.53 26-OCT-06:10 0.00 0.00 0.00 0.00 0.00
November 0.263597E+10 239488.46 22-NOV-07:10 0.00 0.00 0.00 0.00 0.00
December 0.365460E+10 282386.55 18-DEC-07:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.229867E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 5074.21 8.46   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.707458E+10 351225.42   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: CORE_MID VAV BOX REHEAT COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.213059E+10 468394.04 10-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 0.379326E+09 470182.69 13-FEB-06:01 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.250992E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.213059E+10 470182.69   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.360648E+11 118557.39 02-JAN-06:04 0.00 0.00 0.00 0.00 0.00
February 0.172418E+11 117541.33 11-FEB-06:03 0.00 0.00 0.00 0.00 0.00
March 0.777762E+09 66756.81 23-MAR-05:03 0.00 0.00 0.00 0.00 0.00
April 0.170315E+09 17345.42 07-APR-05:05 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.288616E+09 87448.67 26-OCT-05:03 0.00 0.00 0.00 0.00 0.00
November 0.317756E+10 117186.25 21-NOV-06:03 0.00 0.00 0.00 0.00 0.00
December 0.144634E+11 117831.30 07-DEC-06:03 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.721842E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.360648E+11 118557.39   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.203322E+11 130231.17 09-JAN-06:04 0.00 0.00 0.00 0.00 0.00
February 0.932529E+10 129717.86 13-FEB-06:03 0.00 0.00 0.00 0.00 0.00
March 0.374360E+09 62093.17 23-MAR-05:03 0.00 0.00 0.00 0.00 0.00
April 54591697.88 14618.15 06-APR-05:05 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.266459E+09 47578.29 26-OCT-05:03 0.00 0.00 0.00 0.00 0.00
November 0.124717E+10 129170.87 22-NOV-05:01 0.00 0.00 0.00 0.00 0.00
December 0.720137E+10 129578.70 04-DEC-05:02 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.388015E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.203322E+11 130231.17   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.153325E+11 136368.69 04-JAN-05:03 0.00 0.00 0.00 0.00 0.00
February 0.670129E+10 135964.45 13-FEB-06:03 0.00 0.00 0.00 0.00 0.00
March 0.163768E+09 42151.33 23-MAR-05:03 0.00 0.00 0.00 0.00 0.00
April 27716709.59 5473.14 06-APR-06:00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.112931E+09 11806.47 31-OCT-05:06 0.00 0.00 0.00 0.00 0.00
November 0.638145E+09 135130.43 21-NOV-06:01 0.00 0.00 0.00 0.00 0.00
December 0.437149E+10 136512.44 26-DEC-06:02 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.273478E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.153325E+11 136512.44   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.159681E+11 133415.43 14-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 0.694803E+10 133422.60 03-FEB-06:01 0.00 0.00 0.00 0.00 0.00
March 93472455.30 14021.29 23-MAR-05:05 0.00 0.00 0.00 0.00 0.00
April 7076707.99 1975.97 06-APR-07:00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 98812562.23 9470.51 31-OCT-05:20 0.00 0.00 0.00 0.00 0.00
November 0.104174E+10 131880.66 22-NOV-06:01 0.00 0.00 0.00 0.00 0.00
December 0.517656E+10 132022.06 01-DEC-06:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.293338E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.159681E+11 133422.60   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: VAV_TOP WITH REHEAT HEATING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.678817E+09 33173.68 06-JAN-07:10 0.00 0.00 0.00 0.00 0.00
February 0.492117E+09 42978.80 03-FEB-07:10 0.00 0.00 0.00 0.00 0.00
March 74301729.63 16164.33 18-MAR-06:10 0.00 0.00 0.00 0.00 0.00
April 0.124322E+09 19263.90 06-APR-06:10 0.00 0.00 0.00 0.00 0.00
May 0.123999E+09 11314.52 16-MAY-16:20 0.00 0.00 0.00 0.00 0.00
June 32905417.21 5379.56 02-JUN-14:30 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 3222952.21 4058.42 25-AUG-11:30 0.00 0.00 0.00 0.00 0.00
September 16377797.87 2406.14 22-SEP-14:40 0.00 0.00 0.00 0.00 0.00
October 44700087.14 17768.48 26-OCT-06:10 0.00 0.00 0.00 0.00 0.00
November 0.146105E+09 29853.20 22-NOV-07:10 0.00 0.00 0.00 0.00 0.00
December 0.300699E+09 35013.72 18-DEC-07:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.203757E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.678817E+09 42978.80   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: CORE_TOP VAV BOX REHEAT COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.847502E+10 72967.05 02-JAN-05:05 0.00 0.00 0.00 0.00 0.00
February 0.388762E+10 72381.96 07-FEB-06:03 0.00 0.00 0.00 0.00 0.00
March 94862666.70 53774.66 20-MAR-05:03 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 87532387.01 56514.11 30-OCT-05:03 0.00 0.00 0.00 0.00 0.00
November 0.712196E+09 72196.57 22-NOV-06:03 0.00 0.00 0.00 0.00 0.00
December 0.413808E+10 72865.58 26-DEC-05:06 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.173953E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.847502E+10 72967.05   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.795545E+10 13568.75 02-JAN-04:55 0.00 0.00 0.00 0.00 0.00
February 0.448864E+10 13537.41 08-FEB-06:05 0.00 0.00 0.00 0.00 0.00
March 0.735113E+09 13449.38 23-MAR-04:03 0.00 0.00 0.00 0.00 0.00
April 0.184904E+09 13402.90 27-APR-05:03 0.00 0.00 0.00 0.00 0.00
May 35845.81 44.79 11-MAY-05:40 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.460828E+09 13473.71 30-OCT-04:03 0.00 0.00 0.00 0.00 0.00
November 0.174284E+10 13489.13 25-NOV-06:04 0.00 0.00 0.00 0.00 0.00
December 0.469239E+10 13522.30 26-DEC-06:17 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.202602E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.795545E+10 13568.75   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.443743E+10 13397.38 18-JAN-05:03 0.00 0.00 0.00 0.00 0.00
February 0.239508E+10 13385.21 07-FEB-05:03 0.00 0.00 0.00 0.00 0.00
March 0.338018E+09 13293.81 06-MAR-06:02 0.00 0.00 0.00 0.00 0.00
April 64344547.69 11726.29 06-APR-05:03 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 5810.79 9.68 29-SEP-07:00 0.00 0.00 0.00 0.00 0.00
October 0.267215E+09 13358.24 25-OCT-05:02 0.00 0.00 0.00 0.00 0.00
November 0.788606E+09 13344.38 21-NOV-06:03 0.00 0.00 0.00 0.00 0.00
December 0.244383E+10 13395.76 01-DEC-06:03 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.107345E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.443743E+10 13397.38   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.422105E+10 15504.89 02-JAN-04:14 0.00 0.00 0.00 0.00 0.00
February 0.237508E+10 15423.13 07-FEB-06:04 0.00 0.00 0.00 0.00 0.00
March 0.341233E+09 15332.95 22-MAR-05:03 0.00 0.00 0.00 0.00 0.00
April 0.104411E+09 15246.77 06-APR-05:03 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.232356E+09 15381.34 30-OCT-05:03 0.00 0.00 0.00 0.00 0.00
November 0.618595E+09 15378.80 22-NOV-06:04 0.00 0.00 0.00 0.00 0.00
December 0.205069E+10 15443.92 26-DEC-05:24 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.994342E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.422105E+10 15504.89   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.384332E+10 15009.23 18-JAN-05:03 0.00 0.00 0.00 0.00 0.00
February 0.195830E+10 15006.86 07-FEB-05:03 0.00 0.00 0.00 0.00 0.00
March 0.238583E+09 12065.40 23-MAR-05:03 0.00 0.00 0.00 0.00 0.00
April 55004980.53 11107.89 06-APR-05:03 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.168982E+09 13566.66 31-OCT-05:02 0.00 0.00 0.00 0.00 0.00
November 0.696704E+09 14956.47 21-NOV-06:03 0.00 0.00 0.00 0.00 0.00
December 0.195937E+10 15014.19 01-DEC-06:03 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.892027E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.384332E+10 15014.19   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: CAV_BAS HEATING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: AIRLOOP DATACENTER BOT HEATING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: AIRLOOP DATACENTER MID HEATING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: AIRLOOP DATACENTER TOP HEATING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: AIRLOOP DATACENTER BOT_SUPPHEATCOIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: AIRLOOP DATACENTER MID_SUPPHEATCOIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: AIRLOOP DATACENTER TOP_SUPPHEATCOIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:05 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: VAV_BOT WITH REHEAT COOLING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.155745E+10 0.148014E+10 34511.59 31-JAN-15:00 34511.59 0.03
February 0.00 0.00 0.744007E+10 0.743343E+10 81310.94 28-FEB-15:00 81310.94 0.04
March 0.00 0.00 0.238177E+11 0.229906E+11 111096.78 30-MAR-15:20 111096.78 0.17
April 0.00 0.00 0.525315E+11 0.501302E+11 145242.79 17-APR-14:15 145242.79 0.39
May 0.00 0.00 0.823595E+11 0.706935E+11 201384.27 19-MAY-14:07 189661.86 0.57
June 0.00 0.00 0.127376E+12 0.110059E+12 199716.30 26-JUN-05:02 140792.35 0.68
July 0.00 0.00 0.152814E+12 0.127561E+12 199463.71 06-JUL-05:03 139891.14 0.83
August 0.00 0.00 0.174329E+12 0.145017E+12 201716.85 10-AUG-05:03 141659.91 0.89
September 0.00 0.00 0.960391E+11 0.805194E+11 200171.35 27-SEP-05:03 138430.00 0.63
October 0.00 0.00 0.449671E+11 0.376853E+11 199546.82 19-OCT-05:02 134566.80 0.24
November 0.00 0.00 0.165685E+11 0.153046E+11 105029.68 27-NOV-06:02 105029.68 0.12
December 0.00 0.00 0.500693E+10 0.419463E+10 92243.74 13-DEC-06:02 43831.44 0.05
                 
Annual Sum or Average 0.00 0.00 0.784806E+12 0.673069E+12       0.39
Minimum of Months 0.00 0.00 0.155745E+10 0.148014E+10 34511.59   34511.59 0.03
Maximum of Months 0.00 0.00 0.174329E+12 0.145017E+12 201716.85   189661.86 0.89



Table of Contents

Report: CoilReportMonthly

For: VAV_MID WITH REHEAT COOLING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.110100E+11 0.104593E+11 212809.01 31-JAN-15:00 212809.01 0.03
February 0.00 0.00 0.537523E+11 0.537523E+11 612224.96 28-FEB-15:00 612224.96 0.03
March 0.00 0.00 0.170511E+12 0.165781E+12 985515.94 30-MAR-15:20 985515.94 0.15
April 0.00 0.00 0.368030E+12 0.353681E+12 1212118.64 17-APR-15:47 1212118.64 0.28
May 0.00 0.00 0.709177E+12 0.608298E+12 1865222.04 31-MAY-05:03 1262770.02 0.54
June 0.00 0.00 0.105066E+13 0.881341E+12 1879977.23 24-JUN-05:02 1270787.45 0.59
July 0.00 0.00 0.117963E+13 0.936349E+12 1921395.48 27-JUL-05:02 1274250.77 0.67
August 0.00 0.00 0.131391E+13 0.102876E+13 1929683.50 05-AUG-05:03 1290924.79 0.70
September 0.00 0.00 0.800945E+12 0.655171E+12 1910219.85 27-SEP-05:03 1278445.20 0.58
October 0.00 0.00 0.336012E+12 0.273714E+12 1952997.21 19-OCT-05:02 1213663.77 0.21
November 0.00 0.00 0.104791E+12 0.989651E+11 614706.35 04-NOV-05:03 323789.37 0.11
December 0.00 0.00 0.267407E+11 0.230094E+11 659859.82 13-DEC-06:02 320322.30 0.05
                 
Annual Sum or Average 0.00 0.00 0.612517E+13 0.508928E+13       0.33
Minimum of Months 0.00 0.00 0.110100E+11 0.104593E+11 212809.01   212809.01 0.03
Maximum of Months 0.00 0.00 0.131391E+13 0.102876E+13 1952997.21   1290924.79 0.70



Table of Contents

Report: CoilReportMonthly

For: VAV_TOP WITH REHEAT COOLING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.108223E+10 0.102578E+10 19832.13 31-JAN-15:00 19832.13 0.03
February 0.00 0.00 0.457326E+10 0.457326E+10 55955.64 28-FEB-15:00 55955.64 0.03
March 0.00 0.00 0.162257E+11 0.158725E+11 110203.12 30-MAR-15:40 110203.12 0.15
April 0.00 0.00 0.379464E+11 0.364837E+11 142488.44 17-APR-15:40 142488.44 0.28
May 0.00 0.00 0.778574E+11 0.675624E+11 189327.60 31-MAY-05:03 126169.71 0.53
June 0.00 0.00 0.118888E+12 0.101316E+12 196117.40 26-JUN-05:02 135729.67 0.59
July 0.00 0.00 0.133940E+12 0.109011E+12 200608.40 27-JUL-05:02 132684.77 0.69
August 0.00 0.00 0.147295E+12 0.118235E+12 206814.05 23-AUG-03:02 139553.07 0.72
September 0.00 0.00 0.835004E+11 0.692100E+11 198829.93 27-SEP-05:03 132854.85 0.58
October 0.00 0.00 0.325709E+11 0.263161E+11 189472.39 19-OCT-05:02 114821.85 0.20
November 0.00 0.00 0.866288E+10 0.815712E+10 41801.82 02-NOV-14:30 41801.82 0.11
December 0.00 0.00 0.229870E+10 0.197643E+10 31217.48 12-DEC-14:00 31217.48 0.05
                 
Annual Sum or Average 0.00 0.00 0.664841E+12 0.559740E+12       0.33
Minimum of Months 0.00 0.00 0.108223E+10 0.102578E+10 19832.13   19832.13 0.03
Maximum of Months 0.00 0.00 0.147295E+12 0.118235E+12 206814.05   142488.44 0.72



Table of Contents

Report: CoilReportMonthly

For: CAV_BAS COOLING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.515848E+09 0.505796E+09 48413.56 19-JAN-06:03 20530.07 0.02
February 0.00 0.00 0.371315E+10 0.369812E+10 52205.37 28-FEB-14:10 52205.37 0.01
March 0.00 0.00 0.111314E+11 0.110818E+11 74611.02 29-MAR-04:12 41831.18 0.12
April 0.00 0.00 0.236136E+11 0.231914E+11 81252.03 03-APR-03:03 81252.03 0.21
May 0.00 0.00 0.432706E+11 0.390764E+11 114911.65 31-MAY-03:02 45708.33 0.42
June 0.00 0.00 0.751714E+11 0.624147E+11 137095.96 26-JUN-03:02 79292.06 0.50
July 0.00 0.00 0.870862E+11 0.681352E+11 140854.16 07-JUL-03:02 76866.69 0.54
August 0.00 0.00 0.104170E+12 0.800542E+11 144952.15 04-AUG-03:02 77290.97 0.62
September 0.00 0.00 0.654298E+11 0.546189E+11 135147.04 04-SEP-10:40 81222.60 0.51
October 0.00 0.00 0.294703E+11 0.246184E+11 133346.69 19-OCT-03:02 72649.68 0.19
November 0.00 0.00 0.974296E+10 0.889942E+10 72417.65 27-NOV-06:02 35838.98 0.08
December 0.00 0.00 0.284879E+10 0.258534E+10 69467.61 13-DEC-06:02 32595.51 0.04
                 
Annual Sum or Average 0.00 0.00 0.456164E+12 0.378880E+12       0.27
Minimum of Months 0.00 0.00 0.515848E+09 0.505796E+09 48413.56   20530.07 0.01
Maximum of Months 0.00 0.00 0.104170E+12 0.800542E+11 144952.15   81252.03 0.62



Table of Contents

Report: CoilReportMonthly

For: AIRLOOP DATACENTER BOT COOLING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.373338E+10 0.371512E+10 2162.98 22-JAN-17:40 2162.98 0.00
February 0.00 0.00 0.861959E+10 0.859988E+10 4463.74 20-FEB-17:45 4440.09 0.00
March 0.00 0.00 0.154884E+11 0.154245E+11 7680.19 31-MAR-24:00 7680.19 0.00
April 0.00 0.00 0.200925E+11 0.199983E+11 8385.16 09-APR-18:23 8385.16 0.00
May 0.00 0.00 0.592302E+10 0.570568E+10 4044.62 31-MAY-23:20 3955.19 0.00
June 0.00 0.00 0.109921E+11 0.106324E+11 5877.30 30-JUN-24:00 5860.47 0.00
July 0.00 0.00 0.165690E+11 0.160958E+11 7790.18 31-JUL-23:53 7763.56 0.00
August 0.00 0.00 0.217033E+11 0.211361E+11 8621.54 21-AUG-15:50 8125.21 0.00
September 0.00 0.00 0.592792E+10 0.563021E+10 3778.05 30-SEP-24:00 3775.45 0.00
October 0.00 0.00 0.106771E+11 0.105328E+11 5686.49 31-OCT-24:00 5686.49 0.00
November 0.00 0.00 0.149045E+11 0.148509E+11 6351.18 11-NOV-16:55 6351.18 0.00
December 0.00 0.00 0.201190E+11 0.200865E+11 8092.36 10-DEC-17:00 8092.36 0.00
                 
Annual Sum or Average 0.00 0.00 0.154750E+12 0.152408E+12       0.00
Minimum of Months 0.00 0.00 0.373338E+10 0.371512E+10 2162.98   2162.98 0.00
Maximum of Months 0.00 0.00 0.217033E+11 0.211361E+11 8621.54   8385.16 0.00



Table of Contents

Report: CoilReportMonthly

For: AIRLOOP DATACENTER MID COOLING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.135072E+11 0.133462E+11 17428.35 20-JAN-17:00 16479.75 0.00
February 0.00 0.00 0.660915E+11 0.658973E+11 39326.17 28-FEB-17:00 39326.17 0.00
March 0.00 0.00 0.140079E+12 0.139438E+12 72251.17 31-MAR-24:00 72251.17 0.00
April 0.00 0.00 0.188899E+12 0.187954E+12 78131.02 04-APR-15:30 75069.47 0.00
May 0.00 0.00 0.538918E+11 0.517531E+11 38329.03 31-MAY-23:20 37368.15 0.00
June 0.00 0.00 0.104026E+12 0.100443E+12 56309.72 30-JUN-24:00 56134.12 0.00
July 0.00 0.00 0.157724E+12 0.153000E+12 75147.16 31-JUL-23:53 74885.54 0.00
August 0.00 0.00 0.207235E+12 0.201567E+12 82371.93 04-AUG-14:40 76589.66 0.00
September 0.00 0.00 0.533788E+11 0.504487E+11 32889.84 30-SEP-24:00 32795.31 0.00
October 0.00 0.00 0.939982E+11 0.925652E+11 49870.54 31-OCT-24:00 49870.54 0.00
November 0.00 0.00 0.130176E+12 0.129641E+12 57785.84 03-NOV-15:20 55257.01 0.00
December 0.00 0.00 0.171720E+12 0.171392E+12 75448.36 13-DEC-16:00 72084.50 0.00
                 
Annual Sum or Average 0.00 0.00 0.138073E+13 0.135745E+13       0.00
Minimum of Months 0.00 0.00 0.135072E+11 0.133462E+11 17428.35   16479.75 0.00
Maximum of Months 0.00 0.00 0.207235E+12 0.201567E+12 82371.93   76589.66 0.00



Table of Contents

Report: CoilReportMonthly

For: AIRLOOP DATACENTER TOP COOLING COIL

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.437924E+09 0.423553E+09 1746.90 20-JAN-17:00 1647.75 0.00
February 0.00 0.00 0.521747E+10 0.519844E+10 3955.90 28-FEB-17:00 3955.90 0.00
March 0.00 0.00 0.131447E+11 0.130810E+11 6998.05 31-MAR-23:30 6998.05 0.00
April 0.00 0.00 0.185126E+11 0.184184E+11 7867.29 09-APR-18:18 7867.29 0.00
May 0.00 0.00 0.534649E+10 0.513196E+10 3813.05 31-MAY-23:20 3717.45 0.00
June 0.00 0.00 0.104965E+11 0.101380E+11 5623.15 30-JUN-24:00 5605.34 0.00
July 0.00 0.00 0.158919E+11 0.154198E+11 7563.56 31-JUL-23:53 7537.25 0.00
August 0.00 0.00 0.208474E+11 0.202808E+11 8321.39 04-AUG-14:30 7761.47 0.00
September 0.00 0.00 0.522606E+10 0.493398E+10 2846.69 30-SEP-23:30 2808.14 0.00
October 0.00 0.00 0.861980E+10 0.847739E+10 4465.59 31-OCT-23:30 4465.59 0.00
November 0.00 0.00 0.116459E+11 0.115929E+11 5793.91 02-NOV-16:00 5609.60 0.00
December 0.00 0.00 0.152446E+11 0.152122E+11 7507.77 13-DEC-16:00 7171.86 0.00
                 
Annual Sum or Average 0.00 0.00 0.130631E+12 0.128308E+12       0.00
Minimum of Months 0.00 0.00 0.437924E+09 0.423553E+09 1746.90   1647.75 0.00
Maximum of Months 0.00 0.00 0.208474E+11 0.202808E+11 8321.39   7867.29 0.00



Table of Contents

Report: PlantLoopDemandReportMonthly

For: HEATSYS1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 0.00 0.00 01-JAN-00:10 47277.95 1340943.21 10-JAN-06:01
February 0.00 0.00 01-FEB-00:10 25281.87 1235016.66 13-FEB-06:01
March 0.00 0.00 01-MAR-00:10 1540.08 354705.16 23-MAR-05:03
April 0.00 0.00 01-APR-00:10 775.79 206070.15 06-APR-06:10
May 0.00 0.00 01-MAY-00:03 644.35 102840.24 15-MAY-14:40
June 0.00 0.00 01-JUN-00:10 263.09 69212.31 02-JUN-14:20
July 0.00 0.00 01-JUL-00:10 0.00 3.62 26-JUL-10:10
August 0.00 0.00 01-AUG-00:05 30.75 47293.03 25-AUG-11:30
September 0.00 0.00 01-SEP-00:10 103.98 55697.11 14-SEP-15:50
October 0.00 0.00 01-OCT-00:10 867.48 296521.76 26-OCT-05:03
November 0.00 0.00 01-NOV-00:10 5194.45 959573.26 21-NOV-06:01
December 0.00 0.00 01-DEC-00:10 18727.03 1061633.25 26-DEC-05:01
             
Annual Sum or Average 0.00     8328.02    
Minimum of Months 0.00 0.00   0.00 3.62  
Maximum of Months 0.00 0.00   47277.95 1340943.21  



Table of Contents

Report: PlantLoopDemandReportMonthly

For: COOLSYS1_SUPPLY

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 13353.13 780238.46 31-JAN-15:50 0.00 0.00 01-JAN-00:10
February 61281.49 1447688.67 28-FEB-15:00 101.80 301104.89 27-FEB-04:03
March 165969.39 1633442.61 30-MAR-13:40 266.10 392454.35 05-MAR-12:03
April 322710.30 1785272.22 14-APR-13:40 14.50 32000.09 29-APR-01:03
May 547076.37 2099877.66 31-MAY-05:03 98.88 403106.38 15-MAY-03:03
June 762553.60 2466686.38 20-JUN-05:04 136.50 259011.54 03-JUN-03:02
July 811104.03 2790906.28 27-JUL-05:04 5.41 72454.02 01-JUL-19:43
August 870144.30 2675148.58 08-AUG-05:04 0.00 0.00 01-AUG-00:05
September 611862.80 2329927.05 08-SEP-05:03 5.65 25719.13 24-SEP-07:53
October 277779.66 2048038.75 19-OCT-05:02 197.08 275381.37 15-OCT-09:13
November 115966.67 1221037.79 02-NOV-14:00 5.82 60730.28 27-NOV-04:02
December 30974.34 1092022.54 12-DEC-14:30 0.00 0.00 01-DEC-00:10
             
Annual Sum or Average 384430.47     69.36    
Minimum of Months 13353.13 780238.46   0.00 0.00  
Maximum of Months 870144.30 2790906.28   266.10 403106.38  



Table of Contents

Report: PlantLoopDemandReportMonthly

For: COOLSYS1_DEMAND

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 6619.87 517029.10 31-JAN-15:50 0.00 0.00 01-JAN-00:10
February 34281.24 924231.40 28-FEB-15:20 0.00 0.00 01-FEB-00:10
March 101191.43 2018715.12 30-MAR-05:02 0.00 0.00 01-MAR-00:10
April 221646.83 2088327.15 03-APR-05:03 0.00 0.00 01-APR-00:10
May 402680.96 3742127.75 31-MAY-05:03 0.00 0.00 01-MAY-00:03
June 604213.49 3927319.29 19-JUN-05:02 0.00 0.00 01-JUN-00:10
July 652121.90 3927069.03 27-JUL-05:02 0.00 0.00 01-JUL-00:10
August 716653.58 3926068.50 08-AUG-05:02 0.00 0.00 01-AUG-00:05
September 471499.44 3855011.56 11-SEP-05:02 0.00 0.00 01-SEP-00:10
October 202170.95 3967514.01 19-OCT-05:02 0.00 0.00 01-OCT-00:10
November 67444.58 1376370.99 04-NOV-05:03 0.00 0.00 01-NOV-00:10
December 17345.90 1313763.44 13-DEC-06:02 0.00 0.00 01-DEC-00:10
             
Annual Sum or Average 293058.43     0.00    
Minimum of Months 6619.87 517029.10   0.00 0.00  
Maximum of Months 716653.58 3967514.01   0.00 0.00  



Table of Contents

Report: PlantLoopDemandReportMonthly

For: SINGLE WATER PLANT LOOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 9102.51 54427.24 31-JAN-15:00 0.00 0.00 01-JAN-00:10
February 44296.20 132164.26 28-FEB-15:00 0.00 0.00 01-FEB-00:10
March 86709.73 200508.26 30-MAR-14:30 0.00 0.00 01-MAR-00:10
April 132544.06 242508.83 17-APR-15:47 0.00 0.00 01-APR-00:10
May 65728.56 176745.34 19-MAY-13:20 0.00 0.00 01-MAY-00:03
June 134993.62 240766.23 06-JUN-15:00 0.00 0.00 01-JUN-00:10
July 178780.96 296395.27 08-JUL-16:00 0.00 0.00 01-JUL-00:10
August 215597.09 311902.50 01-AUG-16:10 0.00 0.00 01-AUG-00:05
September 80153.69 181720.20 07-SEP-16:00 0.00 0.00 01-SEP-00:10
October 68410.44 192541.01 10-OCT-16:00 0.00 0.00 01-OCT-00:10
November 79960.49 154706.01 05-NOV-16:00 0.00 0.00 01-NOV-00:10
December 96132.78 170649.61 12-DEC-15:00 0.00 0.00 01-DEC-00:10
             
Annual Sum or Average 99737.46     0.00    
Minimum of Months 9102.51 54427.24   0.00 0.00  
Maximum of Months 215597.09 311902.50   0.00 0.00  



Table of Contents

Report: PlantLoopDemandReportMonthly

For: SWHSYS1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 0.00 0.00 01-JAN-00:10 14862.00 49723.87 27-JAN-12:10
February 0.00 0.00 01-FEB-00:10 14972.78 49707.90 02-FEB-12:30
March 0.00 0.00 01-MAR-00:10 15327.88 48924.91 01-MAR-12:50
April 0.00 0.00 01-APR-00:10 13622.89 46288.32 03-APR-11:20
May 0.00 0.00 01-MAY-00:03 13023.65 43165.99 01-MAY-11:40
June 0.00 0.00 01-JUN-00:10 12357.14 39662.83 01-JUN-12:00
July 0.00 0.00 01-JUL-00:10 10969.79 36986.68 03-JUL-11:50
August 0.00 0.00 01-AUG-00:05 11839.39 36860.94 31-AUG-11:30
September 0.00 0.00 01-SEP-00:10 11664.77 39123.54 29-SEP-12:00
October 0.00 0.00 01-OCT-00:10 12488.16 42651.29 31-OCT-11:20
November 0.00 0.00 01-NOV-00:10 13633.59 46037.83 30-NOV-12:30
December 0.00 0.00 01-DEC-00:10 14031.15 48599.22 29-DEC-12:20
             
Annual Sum or Average 0.00     13222.99    
Minimum of Months 0.00 0.00   10969.79 36860.94  
Maximum of Months 0.00 0.00   15327.88 49723.87  



Table of Contents

Report: PlantLoopDemandReportMonthly

For: TOWERWATERSYS

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 6902.97 448850.48 31-JAN-15:50 1883.61 165345.23 14-JAN-10:00
February 35592.47 977237.28 28-FEB-15:40 2029.89 165059.28 03-FEB-08:50
March 100182.06 2577679.09 30-MAR-14:20 1518.81 108071.20 07-MAR-14:10
April 230323.22 2582771.55 18-APR-12:00 1124.98 116618.09 06-APR-09:40
May 491018.01 4016070.15 31-MAY-13:10 144.45 53197.12 10-MAY-09:50
June 1262015.93 4938643.53 23-JUN-12:30 98.70 57937.77 10-JUN-05:40
July 1619394.80 5264836.79 07-JUL-12:00 0.00 12.07 03-JUL-02:50
August 1953980.44 5368951.85 10-AUG-16:00 0.00 0.00 01-AUG-00:05
September 819274.24 4852998.71 06-SEP-12:10 77.03 43407.42 18-SEP-06:30
October 264032.27 4219990.70 18-OCT-13:30 617.48 101889.48 13-OCT-05:40
November 68776.93 717332.13 02-NOV-14:10 1378.55 124222.88 14-NOV-06:30
December 17458.42 646483.47 12-DEC-14:30 1721.43 143219.77 21-DEC-11:20
             
Annual Sum or Average 576576.27     875.82    
Minimum of Months 6902.97 448850.48   0.00 0.00  
Maximum of Months 1953980.44 5368951.85   2029.89 165345.23  



Table of Contents

Report: FanReportMonthly

For: CAV_BAS FAN

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.125995E+11 0.81 8388.48 01-JAN-00:30 1.44
February 0.111542E+11 0.79 8388.48 01-FEB-05:03 1.44
March 0.132672E+11 0.85 8388.48 01-MAR-05:03 1.44
April 0.121289E+11 0.80 8388.48 01-APR-04:05 1.44
May 0.128717E+11 0.82 8388.48 01-MAY-03:02 1.43
June 0.130491E+11 0.85 8388.48 01-JUN-04:03 1.43
July 0.127916E+11 0.81 8388.48 01-JUL-03:03 1.42
August 0.142566E+11 0.90 8388.48 01-AUG-03:02 1.43
September 0.135763E+11 0.89 8388.48 01-SEP-03:03 1.42
October 0.136573E+11 0.87 8388.48 02-OCT-00:20 1.42
November 0.131611E+11 0.87 8388.48 01-NOV-03:10 1.44
December 0.128403E+11 0.82 8388.48 01-DEC-04:03 1.44
           
Annual Sum or Average 0.155354E+12 0.84      
Minimum of Months 0.111542E+11 0.79 8388.48   1.42
Maximum of Months 0.142566E+11 0.90 8388.48   1.44



Table of Contents

Report: FanReportMonthly

For: VAV_BOT WITH REHEAT FAN

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.333624E+10 0.32 11284.73 06-JAN-06:01 1.37
February 0.404775E+10 0.37 11284.73 03-FEB-06:01 1.37
March 0.716876E+10 0.49 14398.68 30-MAR-05:02 1.58
April 0.873978E+10 0.58 19703.29 12-APR-13:15 1.93
May 0.832536E+10 0.52 19703.29 15-MAY-14:40 1.93
June 0.110673E+11 0.67 19703.29 02-JUN-14:00 1.93
July 0.125272E+11 0.73 19703.29 03-JUL-05:02 1.93
August 0.144843E+11 0.81 19703.29 01-AUG-05:03 1.93
September 0.848239E+10 0.54 19703.29 07-SEP-05:02 1.93
October 0.712904E+10 0.47 19703.29 10-OCT-05:02 1.93
November 0.618030E+10 0.44 11836.75 06-NOV-16:30 1.41
December 0.542430E+10 0.40 12052.66 13-DEC-06:02 1.41
           
Annual Sum or Average 0.969128E+11 0.53      
Minimum of Months 0.333624E+10 0.32 11284.73   1.37
Maximum of Months 0.144843E+11 0.81 19703.29   1.93



Table of Contents

Report: FanReportMonthly

For: VAV_MID WITH REHEAT FAN

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.265193E+11 0.31 39990.30 02-JAN-06:02 0.78
February 0.270100E+11 0.32 83203.12 25-FEB-06:03 1.19
March 0.418917E+11 0.38 126705.57 31-MAR-05:02 1.53
April 0.510955E+11 0.41 159952.33 14-APR-13:55 1.78
May 0.676127E+11 0.48 182384.25 15-MAY-16:00 1.93
June 0.857189E+11 0.57 182384.25 01-JUN-05:03 1.93
July 0.868326E+11 0.56 182384.25 01-JUL-05:02 1.93
August 0.940410E+11 0.60 182384.25 02-AUG-05:03 1.93
September 0.638207E+11 0.47 182384.25 02-SEP-05:02 1.92
October 0.439562E+11 0.37 180216.89 19-OCT-05:02 1.91
November 0.322927E+11 0.33 81661.97 01-NOV-05:02 1.17
December 0.276794E+11 0.31 81661.97 13-DEC-06:02 1.17
           
Annual Sum or Average 0.648471E+12 0.43      
Minimum of Months 0.265193E+11 0.31 39990.30   0.78
Maximum of Months 0.940410E+11 0.60 182384.25   1.93



Table of Contents

Report: FanReportMonthly

For: VAV_TOP WITH REHEAT FAN

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.325691E+10 0.37 3987.52 02-JAN-04:11 0.75
February 0.287987E+10 0.35 5178.04 28-FEB-16:20 0.86
March 0.354173E+10 0.35 13215.99 31-MAR-05:02 1.50
April 0.456974E+10 0.38 19566.02 12-APR-14:30 1.93
May 0.691097E+10 0.46 19566.02 15-MAY-15:50 1.93
June 0.954409E+10 0.58 19566.02 06-JUN-05:02 1.93
July 0.997398E+10 0.59 19566.02 01-JUL-05:02 1.93
August 0.106953E+11 0.63 19566.02 04-AUG-05:02 1.93
September 0.633761E+10 0.45 19566.02 07-SEP-05:02 1.93
October 0.379965E+10 0.34 14169.24 19-OCT-05:02 1.57
November 0.275489E+10 0.31 6443.21 04-NOV-05:03 0.97
December 0.289983E+10 0.33 3987.52 01-DEC-06:01 0.75
           
Annual Sum or Average 0.671646E+11 0.43      
Minimum of Months 0.275489E+10 0.31 3987.52   0.75
Maximum of Months 0.106953E+11 0.63 19566.02   1.93



Table of Contents

Report: FanReportMonthly

For: AIRLOOP DATACENTER BOT SUPPLY FAN

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.142139E+10 0.95 530.69 01-JAN-00:10 0.95
February 0.128383E+10 0.95 530.69 01-FEB-00:10 0.95
March 0.142139E+10 0.95 530.69 01-MAR-00:10 0.95
April 0.137554E+10 0.95 530.69 01-APR-00:10 0.95
May 0.142139E+10 0.95 530.69 01-MAY-00:03 0.95
June 0.137554E+10 0.95 530.69 01-JUN-00:10 0.95
July 0.142139E+10 0.95 530.69 01-JUL-00:10 0.95
August 0.142139E+10 0.95 530.69 01-AUG-00:05 0.95
September 0.137554E+10 0.95 530.69 01-SEP-00:10 0.95
October 0.142139E+10 0.95 530.69 01-OCT-00:10 0.95
November 0.137554E+10 0.95 530.69 01-NOV-00:10 0.95
December 0.142139E+10 0.95 530.69 01-DEC-00:10 0.95
           
Annual Sum or Average 0.167357E+11 0.95      
Minimum of Months 0.128383E+10 0.95 530.69   0.95
Maximum of Months 0.142139E+10 0.95 530.69   0.95



Table of Contents

Report: FanReportMonthly

For: AIRLOOP DATACENTER MID SUPPLY FAN

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.135144E+11 0.95 5045.68 01-JAN-00:10 0.95
February 0.122065E+11 0.95 5045.68 01-FEB-00:10 0.95
March 0.135144E+11 0.95 5045.68 01-MAR-00:10 0.95
April 0.130784E+11 0.95 5045.68 01-APR-00:10 0.95
May 0.135144E+11 0.95 5045.68 01-MAY-00:03 0.95
June 0.130784E+11 0.95 5045.68 01-JUN-00:10 0.95
July 0.135144E+11 0.95 5045.68 01-JUL-00:10 0.95
August 0.135144E+11 0.95 5045.68 01-AUG-00:05 0.95
September 0.130784E+11 0.95 5045.68 01-SEP-00:10 0.95
October 0.135144E+11 0.95 5045.68 01-OCT-00:10 0.95
November 0.130784E+11 0.95 5045.68 01-NOV-00:10 0.95
December 0.135144E+11 0.95 5045.68 01-DEC-00:10 0.95
           
Annual Sum or Average 0.159121E+12 0.95      
Minimum of Months 0.122065E+11 0.95 5045.68   0.95
Maximum of Months 0.135144E+11 0.95 5045.68   0.95



Table of Contents

Report: FanReportMonthly

For: AIRLOOP DATACENTER TOP SUPPLY FAN

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.137196E+10 0.95 512.23 01-JAN-00:10 0.94
February 0.123919E+10 0.95 512.23 01-FEB-00:10 0.95
March 0.137196E+10 0.95 512.23 01-MAR-00:10 0.95
April 0.132771E+10 0.95 512.23 01-APR-00:10 0.95
May 0.137196E+10 0.95 512.23 01-MAY-00:03 0.95
June 0.132771E+10 0.95 512.23 01-JUN-00:10 0.95
July 0.137196E+10 0.95 512.23 01-JUL-00:10 0.95
August 0.137196E+10 0.95 512.23 01-AUG-00:05 0.95
September 0.132771E+10 0.95 512.23 01-SEP-00:10 0.95
October 0.137196E+10 0.95 512.23 01-OCT-00:10 0.95
November 0.132771E+10 0.95 512.23 01-NOV-00:10 0.95
December 0.137196E+10 0.95 512.23 01-DEC-00:10 0.95
           
Annual Sum or Average 0.161538E+11 0.95      
Minimum of Months 0.123919E+10 0.95 512.23   0.94
Maximum of Months 0.137196E+10 0.95 512.23   0.95



Table of Contents

Report: PumpReportMonthly

For: HEATSYS1 PUMP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PUMP ELECTRICITY ENERGY [J] PUMP FLUID HEAT GAIN ENERGY [J] PUMP ELECTRICITY RATE {Maximum} [W] PUMP ELECTRICITY RATE {TIMESTAMP} PUMP SHAFT POWER {AT MAX/MIN} [W] PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s]
January 0.610311E+09 0.554773E+09 4228.82 09-JAN-06:02 3844.00 3844.00 49.70 9.04
February 0.288465E+09 0.262214E+09 4202.94 13-FEB-06:01 3820.47 3820.47 48.65 8.85
March 17925710.38 16294470.73 1469.63 23-MAR-05:03 1335.90 1335.90 31.00 1.73
April 13724414.53 12475492.81 916.91 06-APR-06:10 833.47 833.47 32.53 1.02
May 13132748.71 11937668.58 623.18 15-MAY-14:40 566.47 566.47 42.79 0.67
June 3968832.30 3607668.56 389.11 02-JUN-14:20 353.70 353.70 39.18 0.41
July 18.26 16.60 0.03 26-JUL-10:10 0.03 0.03 51.47 0.00
August 629278.80 572014.43 350.94 25-AUG-11:30 319.00 319.00 48.71 0.37
September 2278684.14 2071323.88 474.61 14-SEP-15:50 431.42 431.42 52.92 0.50
October 10144200.03 9221077.83 1202.01 26-OCT-05:03 1092.63 1092.63 29.17 1.38
November 62362252.91 56687287.89 3277.07 21-NOV-06:01 2978.86 2978.86 36.17 5.06
December 0.227404E+09 0.206710E+09 3372.09 26-DEC-06:01 3065.23 3065.23 40.14 5.31
                 
Annual Sum or Average 0.125035E+10 0.113656E+10            
Minimum of Months 18.26 16.60 0.03   0.03 0.03 29.17 0.00
Maximum of Months 0.610311E+09 0.554773E+09 4228.82   3844.00 3844.00 52.92 9.04



Table of Contents

Report: PumpReportMonthly

For: COOLSYS1 PUMP SECONDARY

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PUMP ELECTRICITY ENERGY [J] PUMP FLUID HEAT GAIN ENERGY [J] PUMP ELECTRICITY RATE {Maximum} [W] PUMP ELECTRICITY RATE {TIMESTAMP} PUMP SHAFT POWER {AT MAX/MIN} [W] PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s]
January 5041084.70 4582345.99 218.51 31-JAN-15:50 198.62 198.62 8.33 13.79
February 26389203.00 23987785.52 459.61 21-FEB-15:00 417.79 417.79 8.43 20.37
March 0.150494E+09 0.136799E+09 5562.19 30-MAR-05:02 5056.03 5056.03 8.37 64.13
April 0.519307E+09 0.472050E+09 7304.54 03-APR-05:03 6639.82 6639.82 8.56 71.89
May 0.820931E+09 0.746227E+09 23733.11 31-MAY-05:03 21573.40 21573.40 8.06 115.63
June 0.136445E+10 0.124029E+10 23733.11 16-JUN-05:03 21573.40 21573.40 7.92 115.63
July 0.153008E+10 0.139085E+10 23733.11 01-JUL-05:02 21573.40 21573.40 7.93 115.63
August 0.175988E+10 0.159973E+10 23733.11 04-AUG-05:02 21573.40 21573.40 7.56 115.63
September 0.111436E+10 0.101295E+10 23733.11 06-SEP-05:03 21573.40 21573.40 7.90 115.63
October 0.439979E+09 0.399941E+09 23531.02 19-OCT-05:02 21389.70 21389.70 7.93 115.23
November 69938204.03 63573827.46 2245.51 04-NOV-05:03 2041.17 2041.17 8.43 43.25
December 17586705.52 15986315.32 2411.46 13-DEC-06:02 2192.02 2192.02 8.37 44.65
                 
Annual Sum or Average 0.781844E+10 0.710696E+10            
Minimum of Months 5041084.70 4582345.99 218.51   198.62 198.62 7.56 13.79
Maximum of Months 0.175988E+10 0.159973E+10 23733.11   21573.40 21573.40 8.56 115.63



Table of Contents

Report: PumpReportMonthly

For: COOLSYS1 PUMP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PUMP ELECTRICITY ENERGY [J] PUMP FLUID HEAT GAIN ENERGY [J] PUMP ELECTRICITY RATE {Maximum} [W] PUMP ELECTRICITY RATE {TIMESTAMP} PUMP SHAFT POWER {AT MAX/MIN} [W] PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s]
January 0.427673E+10 0.388755E+10 16334.86 02-JAN-20:00 14848.38 14848.38 8.43 115.63
February 0.727554E+10 0.661347E+10 16334.86 01-FEB-14:40 14848.38 14848.38 8.44 115.63
March 0.155282E+11 0.141152E+11 16334.86 01-MAR-05:03 14848.38 14848.38 8.47 115.63
April 0.235362E+11 0.213944E+11 16334.86 01-APR-05:03 14848.38 14848.38 8.81 115.63
May 0.279300E+11 0.253884E+11 16334.86 01-MAY-00:13 14848.38 14848.38 8.33 115.63
June 0.332485E+11 0.302228E+11 16334.86 01-JUN-03:02 14848.38 14848.38 8.66 115.63
July 0.385749E+11 0.350646E+11 16334.86 01-JUL-00:43 14848.38 14848.38 7.57 115.63
August 0.407287E+11 0.370224E+11 16334.86 01-AUG-00:05 14848.38 14848.38 7.14 115.63
September 0.281958E+11 0.256299E+11 16334.86 01-SEP-00:13 14848.38 14848.38 7.71 115.63
October 0.180237E+11 0.163836E+11 16334.86 01-OCT-12:33 14848.38 14848.38 8.19 115.63
November 0.118120E+11 0.107371E+11 16334.86 01-NOV-04:02 14848.38 14848.38 8.72 115.63
December 0.498470E+10 0.453109E+10 16334.86 01-DEC-05:50 14848.38 14848.38 8.43 115.63
                 
Annual Sum or Average 0.254115E+12 0.230990E+12            
Minimum of Months 0.427673E+10 0.388755E+10 16334.86   14848.38 14848.38 7.14 115.63
Maximum of Months 0.407287E+11 0.370224E+11 16334.86   14848.38 14848.38 8.81 115.63



Table of Contents

Report: PumpReportMonthly

For: PLANT CIRC PUMP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PUMP ELECTRICITY ENERGY [J] PUMP FLUID HEAT GAIN ENERGY [J] PUMP ELECTRICITY RATE {Maximum} [W] PUMP ELECTRICITY RATE {TIMESTAMP} PUMP SHAFT POWER {AT MAX/MIN} [W] PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s]
January 0.177929E+10 0.161737E+10 664.31 01-JAN-00:10 603.86 603.86 18.72 2.80
February 0.160710E+10 0.146085E+10 664.31 01-FEB-00:10 603.86 603.86 22.65 2.80
March 0.177929E+10 0.161737E+10 664.31 01-MAR-00:10 603.86 603.86 26.10 2.80
April 0.172189E+10 0.156520E+10 664.31 01-APR-00:10 603.86 603.86 29.15 2.80
May 0.177929E+10 0.161737E+10 664.31 01-MAY-00:03 603.86 603.86 21.48 2.80
June 0.172189E+10 0.156520E+10 664.31 01-JUN-00:10 603.86 603.86 27.56 2.80
July 0.177929E+10 0.161737E+10 664.31 01-JUL-00:10 603.86 603.86 32.00 2.80
August 0.177929E+10 0.161737E+10 664.31 01-AUG-00:05 603.86 603.86 38.20 2.80
September 0.172189E+10 0.156520E+10 664.31 01-SEP-00:10 603.86 603.86 24.97 2.80
October 0.177929E+10 0.161737E+10 664.31 01-OCT-00:10 603.86 603.86 23.34 2.80
November 0.172189E+10 0.156520E+10 664.31 01-NOV-00:10 603.86 603.86 25.90 2.80
December 0.177929E+10 0.161737E+10 664.31 01-DEC-00:10 603.86 603.86 27.72 2.80
                 
Annual Sum or Average 0.209497E+11 0.190432E+11            
Minimum of Months 0.160710E+10 0.146085E+10 664.31   603.86 603.86 18.72 2.80
Maximum of Months 0.177929E+10 0.161737E+10 664.31   603.86 603.86 38.20 2.80



Table of Contents

Report: PumpReportMonthly

For: SWHSYS1 PUMP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PUMP ELECTRICITY ENERGY [J] PUMP FLUID HEAT GAIN ENERGY [J] PUMP ELECTRICITY RATE {Maximum} [W] PUMP ELECTRICITY RATE {TIMESTAMP} PUMP SHAFT POWER {AT MAX/MIN} [W] PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s]
January 11967951.72 3590385.52 5.96 01-JAN-06:10 1.79 1.79 55.91 0.44
February 10809762.85 3242928.85 5.96 01-FEB-06:02 1.79 1.79 56.60 0.44
March 11967951.72 3590385.52 5.96 01-MAR-06:03 1.79 1.79 56.46 0.44
April 11581888.76 3474566.63 5.96 01-APR-05:03 1.79 1.79 55.63 0.44
May 11967951.72 3590385.52 5.96 01-MAY-05:03 1.79 1.79 57.35 0.44
June 11581888.76 3474566.63 5.96 01-JUN-05:03 1.79 1.79 57.17 0.44
July 11967951.72 3590385.52 5.96 01-JUL-05:02 1.79 1.79 56.70 0.44
August 11967951.72 3590385.52 5.96 01-AUG-05:03 1.79 1.79 56.36 0.44
September 11581888.76 3474566.63 5.96 01-SEP-05:03 1.79 1.79 57.04 0.44
October 11967951.72 3590385.52 5.96 01-OCT-05:10 1.79 1.79 56.98 0.44
November 11581888.76 3474566.63 5.96 01-NOV-05:02 1.79 1.79 55.90 0.44
December 11967951.72 3590385.52 5.96 01-DEC-06:01 1.79 1.79 55.98 0.44
                 
Annual Sum or Average 0.140913E+09 42273893.99            
Minimum of Months 10809762.85 3242928.85 5.96   1.79 1.79 55.63 0.44
Maximum of Months 11967951.72 3590385.52 5.96   1.79 1.79 57.35 0.44



Table of Contents

Report: PumpReportMonthly

For: TOWERWATERSYS PUMP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PUMP ELECTRICITY ENERGY [J] PUMP FLUID HEAT GAIN ENERGY [J] PUMP ELECTRICITY RATE {Maximum} [W] PUMP ELECTRICITY RATE {TIMESTAMP} PUMP SHAFT POWER {AT MAX/MIN} [W] PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s]
January 0.527328E+10 0.479341E+10 20161.46 31-JAN-15:50 18326.77 18326.77 22.68 67.76
February 0.900405E+10 0.818468E+10 40324.78 28-FEB-15:00 36655.22 36655.22 22.74 135.52
March 0.193471E+11 0.175865E+11 40412.32 30-MAR-14:20 36734.80 36734.80 25.65 135.52
April 0.303237E+11 0.275642E+11 40412.63 18-APR-12:00 36735.08 36735.08 25.66 135.52
May 0.374259E+11 0.340201E+11 40498.51 31-MAY-13:10 36813.14 36813.14 28.19 135.52
June 0.514353E+11 0.467547E+11 40519.51 12-JUN-10:30 36832.24 36832.24 28.83 135.52
July 0.606365E+11 0.551186E+11 40519.51 05-JUL-08:00 36832.24 36832.24 28.83 135.52
August 0.659705E+11 0.599672E+11 40519.51 01-AUG-09:30 36832.24 36832.24 29.11 135.52
September 0.400343E+11 0.363912E+11 40519.51 05-SEP-12:30 36832.24 36832.24 28.84 135.52
October 0.233661E+11 0.212397E+11 40510.75 18-OCT-13:30 36824.27 36824.27 28.55 135.52
November 0.145653E+11 0.132399E+11 20175.21 02-NOV-14:10 18339.27 18339.27 23.63 67.76
December 0.614756E+10 0.558813E+10 20171.58 12-DEC-14:30 18335.97 18335.97 23.38 67.76
                 
Annual Sum or Average 0.363530E+12 0.330448E+12            
Minimum of Months 0.527328E+10 0.479341E+10 20161.46   18326.77 18326.77 22.68 67.76
Maximum of Months 0.659705E+11 0.599672E+11 40519.51   36832.24 36832.24 29.11 135.52



Table of Contents

Report: CondLoopDemandReportMonthly

For: HEATSYS1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 0.00 0.00 01-JAN-00:10 41.64 41.64 47277.95 1340943.21 10-JAN-06:01
February 0.00 0.00 01-FEB-00:10 23.36 23.36 25281.87 1235016.66 13-FEB-06:01
March 0.00 0.00 01-MAR-00:10 25.07 25.07 1540.08 354705.16 23-MAR-05:03
April 0.00 0.00 01-APR-00:10 38.86 38.86 775.79 206070.15 06-APR-06:10
May 0.00 0.00 01-MAY-00:03 31.93 31.93 644.35 102840.24 15-MAY-14:40
June 0.00 0.00 01-JUN-00:10 42.78 42.78 263.09 69212.31 02-JUN-14:20
July 0.00 0.00 01-JUL-00:10 51.47 51.47 0.00 3.62 26-JUL-10:10
August 0.00 0.00 01-AUG-00:05 51.47 51.47 30.75 47293.03 25-AUG-11:30
September 0.00 0.00 01-SEP-00:10 50.85 50.85 103.98 55697.11 14-SEP-15:50
October 0.00 0.00 01-OCT-00:10 44.75 44.75 867.48 296521.76 26-OCT-05:03
November 0.00 0.00 01-NOV-00:10 22.81 22.81 5194.45 959573.26 21-NOV-06:01
December 0.00 0.00 01-DEC-00:10 35.58 35.58 18727.03 1061633.25 26-DEC-05:01
                 
Annual Sum or Average 0.00         8328.02    
Minimum of Months 0.00 0.00   22.81 22.81 0.00 3.62  
Maximum of Months 0.00 0.00   51.47 51.47 47277.95 1340943.21  



Table of Contents

Report: CondLoopDemandReportMonthly

For: COOLSYS1_SUPPLY

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 13353.13 780238.46 31-JAN-15:50 9.29 8.48 0.00 0.00 01-JAN-00:10
February 61281.49 1447688.67 28-FEB-15:00 9.94 8.32 101.80 301104.89 27-FEB-04:03
March 165969.39 1633442.61 30-MAR-13:40 10.07 8.04 266.10 392454.35 05-MAR-12:03
April 322710.30 1785272.22 14-APR-13:40 10.38 8.12 14.50 32000.09 29-APR-01:03
May 547076.37 2099877.66 31-MAY-05:03 12.06 7.72 98.88 403106.38 15-MAY-03:03
June 762553.60 2466686.38 20-JUN-05:04 12.89 7.80 136.50 259011.54 03-JUN-03:02
July 811104.03 2790906.28 27-JUL-05:04 13.15 7.47 5.41 72454.02 01-JUL-19:43
August 870144.30 2675148.58 08-AUG-05:04 13.14 7.62 0.00 0.00 01-AUG-00:05
September 611862.80 2329927.05 08-SEP-05:03 12.35 7.54 5.65 25719.13 24-SEP-07:53
October 277779.66 2048038.75 19-OCT-05:02 11.80 7.57 197.08 275381.37 15-OCT-09:13
November 115966.67 1221037.79 02-NOV-14:00 9.73 8.47 5.82 60730.28 27-NOV-04:02
December 30974.34 1092022.54 12-DEC-14:30 9.54 8.41 0.00 0.00 01-DEC-00:10
                 
Annual Sum or Average 384430.47         69.36    
Minimum of Months 13353.13 780238.46   9.29 7.47 0.00 0.00  
Maximum of Months 870144.30 2790906.28   13.15 8.48 266.10 403106.38  



Table of Contents

Report: CondLoopDemandReportMonthly

For: COOLSYS1_DEMAND

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 6619.87 517029.10 31-JAN-15:50 15.66 8.46 0.00 0.00 01-JAN-00:10
February 34281.24 924231.40 28-FEB-15:20 17.71 8.37 0.00 0.00 01-FEB-00:10
March 101191.43 2018715.12 30-MAR-05:02 14.22 8.71 0.00 0.00 01-MAR-00:10
April 221646.83 2088327.15 03-APR-05:03 13.64 8.79 0.00 0.00 01-APR-00:10
May 402680.96 3742127.75 31-MAY-05:03 14.43 7.76 0.00 0.00 01-MAY-00:03
June 604213.49 3927319.29 19-JUN-05:02 14.82 7.96 0.00 0.00 01-JUN-00:10
July 652121.90 3927069.03 27-JUL-05:02 14.86 7.70 0.00 0.00 01-JUL-00:10
August 716653.58 3926068.50 08-AUG-05:02 14.81 7.89 0.00 0.00 01-AUG-00:05
September 471499.44 3855011.56 11-SEP-05:02 14.70 7.98 0.00 0.00 01-SEP-00:10
October 202170.95 3967514.01 19-OCT-05:02 14.93 7.59 0.00 0.00 01-OCT-00:10
November 67444.58 1376370.99 04-NOV-05:03 14.30 8.76 0.00 0.00 01-NOV-00:10
December 17345.90 1313763.44 13-DEC-06:02 13.73 8.61 0.00 0.00 01-DEC-00:10
                 
Annual Sum or Average 293058.43         0.00    
Minimum of Months 6619.87 517029.10   13.64 7.59 0.00 0.00  
Maximum of Months 716653.58 3967514.01   17.71 8.79 0.00 0.00  



Table of Contents

Report: CondLoopDemandReportMonthly

For: SINGLE WATER PLANT LOOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 9102.51 54427.24 31-JAN-15:00 23.91 21.39 0.00 0.00 01-JAN-00:10
February 44296.20 132164.26 28-FEB-15:00 31.78 25.72 0.00 0.00 01-FEB-00:10
March 86709.73 200508.26 30-MAR-14:30 38.60 28.96 0.00 0.00 01-MAR-00:10
April 132544.06 242508.83 17-APR-15:47 42.75 30.40 0.00 0.00 01-APR-00:10
May 65728.56 176745.34 19-MAY-13:20 36.24 30.84 0.00 0.00 01-MAY-00:03
June 134993.62 240766.23 06-JUN-15:00 42.58 35.28 0.00 0.00 01-JUN-00:10
July 178780.96 296395.27 08-JUL-16:00 48.02 37.94 0.00 0.00 01-JUL-00:10
August 215597.09 311902.50 01-AUG-16:10 49.53 36.59 0.00 0.00 01-AUG-00:05
September 80153.69 181720.20 07-SEP-16:00 36.73 32.24 0.00 0.00 01-SEP-00:10
October 68410.44 192541.01 10-OCT-16:00 37.81 30.84 0.00 0.00 01-OCT-00:10
November 79960.49 154706.01 05-NOV-16:00 34.04 25.42 0.00 0.00 01-NOV-00:10
December 96132.78 170649.61 12-DEC-15:00 35.63 24.17 0.00 0.00 01-DEC-00:10
                 
Annual Sum or Average 99737.46         0.00    
Minimum of Months 9102.51 54427.24   23.91 21.39 0.00 0.00  
Maximum of Months 215597.09 311902.50   49.53 37.94 0.00 0.00  



Table of Contents

Report: CondLoopDemandReportMonthly

For: SWHSYS1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 0.00 0.00 01-JAN-00:10 57.66 57.66 14862.00 49723.87 27-JAN-12:10
February 0.00 0.00 01-FEB-00:10 57.11 57.11 14972.78 49707.90 02-FEB-12:30
March 0.00 0.00 01-MAR-00:10 57.04 57.04 15327.88 48924.91 01-MAR-12:50
April 0.00 0.00 01-APR-00:10 56.21 56.21 13622.89 46288.32 03-APR-11:20
May 0.00 0.00 01-MAY-00:03 58.08 58.08 13023.65 43165.99 01-MAY-11:40
June 0.00 0.00 01-JUN-00:10 57.60 57.60 12357.14 39662.83 01-JUN-12:00
July 0.00 0.00 01-JUL-00:10 57.05 57.05 10969.79 36986.68 03-JUL-11:50
August 0.00 0.00 01-AUG-00:05 56.77 56.77 11839.39 36860.94 31-AUG-11:30
September 0.00 0.00 01-SEP-00:10 57.44 57.44 11664.77 39123.54 29-SEP-12:00
October 0.00 0.00 01-OCT-00:10 57.73 57.73 12488.16 42651.29 31-OCT-11:20
November 0.00 0.00 01-NOV-00:10 56.37 56.37 13633.59 46037.83 30-NOV-12:30
December 0.00 0.00 01-DEC-00:10 56.46 56.46 14031.15 48599.22 29-DEC-12:20
                 
Annual Sum or Average 0.00         13222.99    
Minimum of Months 0.00 0.00   56.21 56.21 10969.79 36860.94  
Maximum of Months 0.00 0.00   58.08 58.08 15327.88 49723.87  



Table of Contents

Report: CondLoopDemandReportMonthly

For: TOWERWATERSYS

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 6902.97 448850.48 31-JAN-15:50 22.68 21.10 1883.61 165345.23 14-JAN-10:00
February 35592.47 977237.28 28-FEB-15:40 24.55 21.10 2029.89 165059.28 03-FEB-08:50
March 100182.06 2577679.09 30-MAR-14:20 25.65 21.94 1518.81 108071.20 07-MAR-14:10
April 230323.22 2582771.55 18-APR-12:00 25.66 21.81 1124.98 116618.09 06-APR-09:40
May 491018.01 4016070.15 31-MAY-13:10 28.19 25.03 144.45 53197.12 10-MAY-09:50
June 1262015.93 4938643.53 23-JUN-12:30 29.82 26.75 98.70 57937.77 10-JUN-05:40
July 1619394.80 5264836.79 07-JUL-12:00 30.39 27.40 0.00 12.07 03-JUL-02:50
August 1953980.44 5368951.85 10-AUG-16:00 30.58 27.48 0.00 0.00 01-AUG-00:05
September 819274.24 4852998.71 06-SEP-12:10 29.67 26.46 77.03 43407.42 18-SEP-06:30
October 264032.27 4219990.70 18-OCT-13:30 28.55 25.36 617.48 101889.48 13-OCT-05:40
November 68776.93 717332.13 02-NOV-14:10 23.63 21.10 1378.55 124222.88 14-NOV-06:30
December 17458.42 646483.47 12-DEC-14:30 23.38 21.10 1721.43 143219.77 21-DEC-11:20
                 
Annual Sum or Average 576576.27         875.82    
Minimum of Months 6902.97 448850.48   22.68 21.10 0.00 0.00  
Maximum of Months 1953980.44 5368951.85   30.58 27.48 2029.89 165345.23  



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: BASEMENT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: CORE_BOTTOM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: CORE_MID

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: CORE_TOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_BOT_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_BOT_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_BOT_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_BOT_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_MID_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_MID_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_MID_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_MID_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_TOP_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_TOP_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_TOP_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_TOP_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: GROUNDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00 0.00
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: MIDFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00 0.00
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: TOPFLOOR_PLENUM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00 0.00
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: DATACENTER_BOT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: DATACENTER_MID_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: DATACENTER_TOP_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: DATACENTER_BASEMENT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: VAV_BOT WITH REHEAT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.138782E+10 0.00 0.155745E+10 0.333624E+10 0.00 0.00
February 0.557421E+09 0.00 0.744007E+10 0.404775E+10 0.00 0.00
March 40577782.93 0.00 0.238177E+11 0.716876E+10 0.00 0.00
April 0.148729E+09 0.00 0.525315E+11 0.873978E+10 0.00 0.00
May 0.186207E+09 0.00 0.823595E+11 0.832536E+10 0.00 0.00
June 23895325.41 0.00 0.127376E+12 0.110673E+11 0.00 0.00
July 0.00 0.00 0.152814E+12 0.125272E+11 0.00 0.00
August 10137995.85 0.00 0.174329E+12 0.144843E+11 0.00 0.00
September 34894515.19 0.00 0.960391E+11 0.848239E+10 0.00 0.00
October 12625255.81 0.00 0.449671E+11 0.712904E+10 0.00 0.00
November 78352524.92 0.00 0.165685E+11 0.618030E+10 0.00 0.00
December 0.236486E+09 0.00 0.500693E+10 0.542430E+10 0.00 0.00
             
Annual Sum or Average 0.271715E+10 0.00 0.784806E+12 0.969128E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.155745E+10 0.333624E+10 0.00 0.00
Maximum of Months 0.138782E+10 0.00 0.174329E+12 0.144843E+11 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: VAV_MID WITH REHEAT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.969027E+11 0.00 0.110100E+11 0.265193E+11 0.00 0.00
February 0.455615E+11 0.00 0.537523E+11 0.270100E+11 0.00 0.00
March 0.223548E+10 0.00 0.170511E+12 0.418917E+11 0.00 0.00
April 0.138299E+10 0.00 0.368030E+12 0.510955E+11 0.00 0.00
May 0.138596E+10 0.00 0.709177E+12 0.676127E+11 0.00 0.00
June 0.590359E+09 0.00 0.105066E+13 0.857189E+11 0.00 0.00
July 5074.21 0.00 0.117963E+13 0.868326E+11 0.00 0.00
August 72894317.12 0.00 0.131391E+13 0.940410E+11 0.00 0.00
September 0.250679E+09 0.00 0.800945E+12 0.638207E+11 0.00 0.00
October 0.117332E+10 0.00 0.336012E+12 0.439562E+11 0.00 0.00
November 0.874058E+10 0.00 0.104791E+12 0.322927E+11 0.00 0.00
December 0.348674E+11 0.00 0.267407E+11 0.276794E+11 0.00 0.00
             
Annual Sum or Average 0.193164E+12 0.00 0.612517E+13 0.648471E+12 0.00 0.00
Minimum of Months 5074.21 0.00 0.110100E+11 0.265193E+11 0.00 0.00
Maximum of Months 0.969027E+11 0.00 0.131391E+13 0.940410E+11 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: VAV_TOP WITH REHEAT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.296111E+11 0.00 0.108223E+10 0.325691E+10 0.00 0.00
February 0.155968E+11 0.00 0.457326E+10 0.287987E+10 0.00 0.00
March 0.182211E+10 0.00 0.162257E+11 0.354173E+10 0.00 0.00
April 0.532986E+09 0.00 0.379464E+11 0.456974E+10 0.00 0.00
May 0.124035E+09 0.00 0.778574E+11 0.691097E+10 0.00 0.00
June 32905417.21 0.00 0.118888E+12 0.954409E+10 0.00 0.00
July 0.00 0.00 0.133940E+12 0.997398E+10 0.00 0.00
August 3222952.21 0.00 0.147295E+12 0.106953E+11 0.00 0.00
September 16383608.66 0.00 0.835004E+11 0.633761E+10 0.00 0.00
October 0.126161E+10 0.00 0.325709E+11 0.379965E+10 0.00 0.00
November 0.470505E+10 0.00 0.866288E+10 0.275489E+10 0.00 0.00
December 0.155851E+11 0.00 0.229870E+10 0.289983E+10 0.00 0.00
             
Annual Sum or Average 0.692913E+11 0.00 0.664841E+12 0.671646E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.108223E+10 0.275489E+10 0.00 0.00
Maximum of Months 0.296111E+11 0.00 0.147295E+12 0.106953E+11 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: CAV_BAS

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.515848E+09 0.125995E+11 0.00 0.00
February 0.00 0.00 0.371315E+10 0.111542E+11 0.00 0.00
March 0.00 0.00 0.111314E+11 0.132672E+11 0.00 0.00
April 0.00 0.00 0.236136E+11 0.121289E+11 0.00 0.00
May 0.00 0.00 0.432706E+11 0.128717E+11 0.00 0.00
June 0.00 0.00 0.751714E+11 0.130491E+11 0.00 0.00
July 0.00 0.00 0.870862E+11 0.127916E+11 0.00 0.00
August 0.00 0.00 0.104170E+12 0.142566E+11 0.00 0.00
September 0.00 0.00 0.654298E+11 0.135763E+11 0.00 0.00
October 0.00 0.00 0.294703E+11 0.136573E+11 0.00 0.00
November 0.00 0.00 0.974296E+10 0.131611E+11 0.00 0.00
December 0.00 0.00 0.284879E+10 0.128403E+11 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.456164E+12 0.155354E+12 0.00 0.00
Minimum of Months 0.00 0.00 0.515848E+09 0.111542E+11 0.00 0.00
Maximum of Months 0.00 0.00 0.104170E+12 0.142566E+11 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: AIRLOOP DATACENTER BOT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.465644E+10 0.234445E+10 0.00 0.00
February 0.00 0.00 0.105868E+11 0.325108E+10 0.00 0.00
March 0.00 0.00 0.188455E+11 0.477850E+10 0.00 0.00
April 0.00 0.00 0.244378E+11 0.572084E+10 0.00 0.00
May 0.00 0.00 0.742135E+10 0.291972E+10 0.00 0.00
June 0.00 0.00 0.139289E+11 0.431230E+10 0.00 0.00
July 0.00 0.00 0.209759E+11 0.582825E+10 0.00 0.00
August 0.00 0.00 0.273871E+11 0.710516E+10 0.00 0.00
September 0.00 0.00 0.747611E+10 0.292372E+10 0.00 0.00
October 0.00 0.00 0.130961E+11 0.384039E+10 0.00 0.00
November 0.00 0.00 0.181148E+11 0.458584E+10 0.00 0.00
December 0.00 0.00 0.242891E+11 0.559148E+10 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.191216E+12 0.532017E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.465644E+10 0.234445E+10 0.00 0.00
Maximum of Months 0.00 0.00 0.273871E+11 0.710516E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: AIRLOOP DATACENTER MID

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.171124E+11 0.171195E+11 0.00 0.00
February 0.00 0.00 0.814827E+11 0.275977E+11 0.00 0.00
March 0.00 0.00 0.170654E+12 0.440898E+11 0.00 0.00
April 0.00 0.00 0.229854E+12 0.540327E+11 0.00 0.00
May 0.00 0.00 0.676353E+11 0.272579E+11 0.00 0.00
June 0.00 0.00 0.131856E+12 0.409084E+11 0.00 0.00
July 0.00 0.00 0.199680E+12 0.554711E+11 0.00 0.00
August 0.00 0.00 0.261472E+12 0.677517E+11 0.00 0.00
September 0.00 0.00 0.674079E+11 0.271075E+11 0.00 0.00
October 0.00 0.00 0.115493E+12 0.350089E+11 0.00 0.00
November 0.00 0.00 0.158516E+12 0.414178E+11 0.00 0.00
December 0.00 0.00 0.207854E+12 0.496485E+11 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.170902E+13 0.487412E+12 0.00 0.00
Minimum of Months 0.00 0.00 0.171124E+11 0.171195E+11 0.00 0.00
Maximum of Months 0.00 0.00 0.261472E+12 0.677517E+11 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: AIRLOOP DATACENTER TOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.554214E+09 0.148825E+10 0.00 0.00
February 0.00 0.00 0.644955E+10 0.247126E+10 0.00 0.00
March 0.00 0.00 0.160395E+11 0.426679E+10 0.00 0.00
April 0.00 0.00 0.225490E+11 0.536412E+10 0.00 0.00
May 0.00 0.00 0.671348E+10 0.273895E+10 0.00 0.00
June 0.00 0.00 0.133092E+11 0.414035E+10 0.00 0.00
July 0.00 0.00 0.201270E+11 0.560704E+10 0.00 0.00
August 0.00 0.00 0.263129E+11 0.683742E+10 0.00 0.00
September 0.00 0.00 0.660866E+10 0.271031E+10 0.00 0.00
October 0.00 0.00 0.106137E+11 0.336587E+10 0.00 0.00
November 0.00 0.00 0.142141E+11 0.389585E+10 0.00 0.00
December 0.00 0.00 0.185035E+11 0.463086E+10 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.161995E+12 0.475171E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.554214E+09 0.148825E+10 0.00 0.00
Maximum of Months 0.00 0.00 0.263129E+11 0.683742E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: VAV_BOT WITH REHEAT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.333624E+10 0.155745E+10 0.138782E+10 0.119102E+11 0.00 0.00 0.00 0.00
February 0.404775E+10 0.744007E+10 0.557421E+09 0.564972E+10 0.00 0.00 0.00 0.00
March 0.716876E+10 0.238177E+11 40577782.93 0.301248E+09 69769413.22 0.00 0.00 0.00
April 0.873978E+10 0.525315E+11 0.148729E+09 0.114653E+09 0.302895E+09 0.00 0.00 0.00
May 0.832536E+10 0.823595E+11 0.186207E+09 0.00 0.224772E+10 0.00 0.00 0.00
June 0.110673E+11 0.127376E+12 23895325.41 0.00 0.139677E+11 0.00 0.00 0.00
July 0.125272E+11 0.152814E+12 0.00 0.00 0.193707E+11 0.00 0.00 0.00
August 0.144843E+11 0.174329E+12 10137995.85 0.00 0.239541E+11 0.00 0.00 0.00
September 0.848239E+10 0.960391E+11 34894515.19 0.00 0.657625E+10 0.00 0.00 0.00
October 0.712904E+10 0.449671E+11 12625255.81 59727285.77 0.126921E+10 0.00 0.00 0.00
November 0.618030E+10 0.165685E+11 78352524.92 0.844752E+09 0.00 0.00 0.00 0.00
December 0.542430E+10 0.500693E+10 0.236486E+09 0.196427E+10 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.969128E+11 0.784806E+12 0.271715E+10 0.208446E+11 0.677584E+11 0.00 0.00 0.00
Minimum of Months 0.333624E+10 0.155745E+10 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.144843E+11 0.174329E+12 0.138782E+10 0.119102E+11 0.239541E+11 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: VAV_MID WITH REHEAT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.265193E+11 0.110100E+11 0.969027E+11 0.167186E+12 0.00 0.00 0.00 0.00
February 0.270100E+11 0.537523E+11 0.455615E+11 0.849248E+11 0.00 0.00 0.00 0.00
March 0.418917E+11 0.170511E+12 0.223548E+10 0.970738E+10 0.867523E+09 0.00 0.00 0.00
April 0.510955E+11 0.368030E+12 0.138299E+10 0.234682E+10 0.288158E+10 0.00 0.00 0.00
May 0.676127E+11 0.709177E+12 0.138596E+10 1368897.70 0.226828E+11 0.00 0.00 0.00
June 0.857189E+11 0.105066E+13 0.590359E+09 0.00 0.140208E+12 0.00 0.00 0.00
July 0.868326E+11 0.117963E+13 5074.21 0.00 0.194571E+12 0.00 0.00 0.00
August 0.940410E+11 0.131391E+13 72894317.12 0.00 0.239320E+12 0.00 0.00 0.00
September 0.638207E+11 0.800945E+12 0.250679E+09 0.00 0.678295E+11 0.00 0.00 0.00
October 0.439562E+11 0.336012E+12 0.117332E+10 0.243853E+10 0.131537E+11 0.00 0.00 0.00
November 0.322927E+11 0.104791E+12 0.874058E+10 0.204645E+11 0.00 0.00 0.00 0.00
December 0.276794E+11 0.267407E+11 0.348674E+11 0.506664E+11 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.648471E+12 0.612517E+13 0.193164E+12 0.337735E+12 0.681514E+12 0.00 0.00 0.00
Minimum of Months 0.265193E+11 0.110100E+11 5074.21 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.940410E+11 0.131391E+13 0.969027E+11 0.167186E+12 0.239320E+12 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: VAV_TOP WITH REHEAT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.325691E+10 0.108223E+10 0.296111E+11 0.195027E+11 0.00 0.00 0.00 0.00
February 0.287987E+10 0.457326E+10 0.155968E+11 0.104208E+11 0.00 0.00 0.00 0.00
March 0.354173E+10 0.162257E+11 0.182211E+10 0.190036E+10 58614210.24 0.00 0.00 0.00
April 0.456974E+10 0.379464E+11 0.532986E+09 0.459191E+09 0.148279E+09 0.00 0.00 0.00
May 0.691097E+10 0.778574E+11 0.124035E+09 8386659.66 0.167757E+10 0.00 0.00 0.00
June 0.954409E+10 0.118888E+12 32905417.21 0.00 0.128905E+11 0.00 0.00 0.00
July 0.997398E+10 0.133940E+12 0.00 0.00 0.183260E+11 0.00 0.00 0.00
August 0.106953E+11 0.147295E+12 3222952.21 0.00 0.226844E+11 0.00 0.00 0.00
September 0.633761E+10 0.835004E+11 16383608.66 0.00 0.626560E+10 0.00 0.00 0.00
October 0.379965E+10 0.325709E+11 0.126161E+10 0.722664E+09 0.945494E+09 0.00 0.00 0.00
November 0.275489E+10 0.866288E+10 0.470505E+10 0.363990E+10 0.00 0.00 0.00 0.00
December 0.289983E+10 0.229870E+10 0.155851E+11 0.735422E+10 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.671646E+11 0.664841E+12 0.692913E+11 0.440082E+11 0.629965E+11 0.00 0.00 0.00
Minimum of Months 0.275489E+10 0.108223E+10 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.106953E+11 0.147295E+12 0.296111E+11 0.195027E+11 0.226844E+11 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: CAV_BAS

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.125995E+11 0.515848E+09 0.00 0.00 0.00 0.00 0.00 0.00
February 0.111542E+11 0.371315E+10 0.00 0.00 0.00 0.00 0.00 0.00
March 0.132672E+11 0.111314E+11 0.00 0.00 0.00 0.00 0.00 0.00
April 0.121289E+11 0.236136E+11 0.00 0.00 0.00 0.00 0.00 0.00
May 0.128717E+11 0.432706E+11 0.00 0.00 0.00 0.00 0.00 0.00
June 0.130491E+11 0.751714E+11 0.00 0.00 0.00 0.00 0.00 0.00
July 0.127916E+11 0.870862E+11 0.00 0.00 0.00 0.00 0.00 0.00
August 0.142566E+11 0.104170E+12 0.00 0.00 0.00 0.00 0.00 0.00
September 0.135763E+11 0.654298E+11 0.00 0.00 0.00 0.00 0.00 0.00
October 0.136573E+11 0.294703E+11 0.00 0.00 0.00 0.00 0.00 0.00
November 0.131611E+11 0.974296E+10 0.00 0.00 0.00 0.00 0.00 0.00
December 0.128403E+11 0.284879E+10 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.155354E+12 0.456164E+12 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.111542E+11 0.515848E+09 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.142566E+11 0.104170E+12 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: AIRLOOP DATACENTER BOT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.142139E+10 0.373338E+10 0.00 0.00 0.00 0.00 0.00 0.00
February 0.128383E+10 0.861959E+10 0.00 0.00 0.00 0.00 0.00 0.00
March 0.142139E+10 0.154884E+11 0.00 0.00 0.00 0.00 0.00 0.00
April 0.137554E+10 0.200925E+11 0.00 0.00 0.00 0.00 0.00 0.00
May 0.142139E+10 0.592302E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.137554E+10 0.109921E+11 0.00 0.00 0.00 0.00 0.00 0.00
July 0.142139E+10 0.165690E+11 0.00 0.00 0.00 0.00 0.00 0.00
August 0.142139E+10 0.217033E+11 0.00 0.00 0.00 0.00 0.00 0.00
September 0.137554E+10 0.592792E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.142139E+10 0.106771E+11 0.00 0.00 0.00 0.00 0.00 0.00
November 0.137554E+10 0.149045E+11 0.00 0.00 0.00 0.00 0.00 0.00
December 0.142139E+10 0.201190E+11 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.167357E+11 0.154750E+12 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.128383E+10 0.373338E+10 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.142139E+10 0.217033E+11 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: AIRLOOP DATACENTER MID

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.135144E+11 0.135072E+11 0.00 0.00 0.00 0.00 0.00 0.00
February 0.122065E+11 0.660915E+11 0.00 0.00 0.00 0.00 0.00 0.00
March 0.135144E+11 0.140079E+12 0.00 0.00 0.00 0.00 0.00 0.00
April 0.130784E+11 0.188899E+12 0.00 0.00 0.00 0.00 0.00 0.00
May 0.135144E+11 0.538918E+11 0.00 0.00 0.00 0.00 0.00 0.00
June 0.130784E+11 0.104026E+12 0.00 0.00 0.00 0.00 0.00 0.00
July 0.135144E+11 0.157724E+12 0.00 0.00 0.00 0.00 0.00 0.00
August 0.135144E+11 0.207235E+12 0.00 0.00 0.00 0.00 0.00 0.00
September 0.130784E+11 0.533788E+11 0.00 0.00 0.00 0.00 0.00 0.00
October 0.135144E+11 0.939982E+11 0.00 0.00 0.00 0.00 0.00 0.00
November 0.130784E+11 0.130176E+12 0.00 0.00 0.00 0.00 0.00 0.00
December 0.135144E+11 0.171720E+12 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.159121E+12 0.138073E+13 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.122065E+11 0.135072E+11 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.135144E+11 0.207235E+12 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: AIRLOOP DATACENTER TOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.137196E+10 0.437924E+09 0.00 0.00 0.00 0.00 0.00 0.00
February 0.123919E+10 0.521747E+10 0.00 0.00 0.00 0.00 0.00 0.00
March 0.137196E+10 0.131447E+11 0.00 0.00 0.00 0.00 0.00 0.00
April 0.132771E+10 0.185126E+11 0.00 0.00 0.00 0.00 0.00 0.00
May 0.137196E+10 0.534649E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.132771E+10 0.104965E+11 0.00 0.00 0.00 0.00 0.00 0.00
July 0.137196E+10 0.158919E+11 0.00 0.00 0.00 0.00 0.00 0.00
August 0.137196E+10 0.208474E+11 0.00 0.00 0.00 0.00 0.00 0.00
September 0.132771E+10 0.522606E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.137196E+10 0.861980E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.132771E+10 0.116459E+11 0.00 0.00 0.00 0.00 0.00 0.00
December 0.137196E+10 0.152446E+11 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.161538E+11 0.130631E+12 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.123919E+10 0.437924E+09 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.137196E+10 0.208474E+11 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: VAV_BOT WITH REHEAT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.333624E+10 0.138782E+10 0.155745E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.404775E+10 0.557421E+09 0.744007E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.716876E+10 40577782.93 0.238177E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.873978E+10 0.148729E+09 0.525315E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.832536E+10 0.186207E+09 0.823595E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.110673E+11 23895325.41 0.127376E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.125272E+11 0.00 0.152814E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.144843E+11 10137995.85 0.174329E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.848239E+10 34894515.19 0.960391E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.712904E+10 12625255.81 0.449671E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.618030E+10 78352524.92 0.165685E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.542430E+10 0.236486E+09 0.500693E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.969128E+11 0.271715E+10 0.784806E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.333624E+10 0.00 0.155745E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.144843E+11 0.138782E+10 0.174329E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: VAV_MID WITH REHEAT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.265193E+11 0.969027E+11 0.110100E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.270100E+11 0.455615E+11 0.537523E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.418917E+11 0.223548E+10 0.170511E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.510955E+11 0.138299E+10 0.368030E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.676127E+11 0.138596E+10 0.709177E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.857189E+11 0.590359E+09 0.105066E+13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.868326E+11 5074.21 0.117963E+13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.940410E+11 72894317.12 0.131391E+13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.638207E+11 0.250679E+09 0.800945E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.439562E+11 0.117332E+10 0.336012E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.322927E+11 0.874058E+10 0.104791E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.276794E+11 0.348674E+11 0.267407E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.648471E+12 0.193164E+12 0.612517E+13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.265193E+11 5074.21 0.110100E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.940410E+11 0.969027E+11 0.131391E+13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: VAV_TOP WITH REHEAT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.325691E+10 0.296111E+11 0.108223E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.287987E+10 0.155968E+11 0.457326E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.354173E+10 0.182211E+10 0.162257E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.456974E+10 0.532986E+09 0.379464E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.691097E+10 0.124035E+09 0.778574E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.954409E+10 32905417.21 0.118888E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.997398E+10 0.00 0.133940E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.106953E+11 3222952.21 0.147295E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.633761E+10 16383608.66 0.835004E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.379965E+10 0.126161E+10 0.325709E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.275489E+10 0.470505E+10 0.866288E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.289983E+10 0.155851E+11 0.229870E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.671646E+11 0.692913E+11 0.664841E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.275489E+10 0.00 0.108223E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.106953E+11 0.296111E+11 0.147295E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: CAV_BAS

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.125995E+11 0.00 0.515848E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.111542E+11 0.00 0.371315E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.132672E+11 0.00 0.111314E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.121289E+11 0.00 0.236136E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.128717E+11 0.00 0.432706E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.130491E+11 0.00 0.751714E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.127916E+11 0.00 0.870862E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.142566E+11 0.00 0.104170E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.135763E+11 0.00 0.654298E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.136573E+11 0.00 0.294703E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.131611E+11 0.00 0.974296E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.128403E+11 0.00 0.284879E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.155354E+12 0.00 0.456164E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.111542E+11 0.00 0.515848E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.142566E+11 0.00 0.104170E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: AIRLOOP DATACENTER BOT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.142139E+10 0.00 0.465644E+10 0.00 0.923067E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.128383E+10 0.00 0.105868E+11 0.00 0.196724E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.142139E+10 0.00 0.188455E+11 0.00 0.335711E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.137554E+10 0.00 0.244378E+11 0.00 0.434530E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.142139E+10 0.00 0.742135E+10 0.00 0.149833E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.137554E+10 0.00 0.139289E+11 0.00 0.293676E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.142139E+10 0.00 0.209759E+11 0.00 0.440686E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.142139E+10 0.00 0.273871E+11 0.00 0.568377E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.137554E+10 0.00 0.747611E+10 0.00 0.154818E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.142139E+10 0.00 0.130961E+11 0.00 0.241900E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.137554E+10 0.00 0.181148E+11 0.00 0.321030E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.142139E+10 0.00 0.242891E+11 0.00 0.417009E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.167357E+11 0.00 0.191216E+12 0.00 0.364660E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.128383E+10 0.00 0.465644E+10 0.00 0.923067E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.142139E+10 0.00 0.273871E+11 0.00 0.568377E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: AIRLOOP DATACENTER MID

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.135144E+11 0.00 0.171124E+11 0.00 0.360514E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.122065E+11 0.00 0.814827E+11 0.00 0.153912E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.135144E+11 0.00 0.170654E+12 0.00 0.305754E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.130784E+11 0.00 0.229854E+12 0.00 0.409543E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.135144E+11 0.00 0.676353E+11 0.00 0.137435E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.130784E+11 0.00 0.131856E+12 0.00 0.278300E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.135144E+11 0.00 0.199680E+12 0.00 0.419568E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.135144E+11 0.00 0.261472E+12 0.00 0.542374E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.130784E+11 0.00 0.674079E+11 0.00 0.140291E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.135144E+11 0.00 0.115493E+12 0.00 0.214946E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.130784E+11 0.00 0.158516E+12 0.00 0.283394E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.135144E+11 0.00 0.207854E+12 0.00 0.361342E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.159121E+12 0.00 0.170902E+13 0.00 0.328291E+12 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.122065E+11 0.00 0.171124E+11 0.00 0.360514E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.135144E+11 0.00 0.261472E+12 0.00 0.542374E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: AIRLOOP DATACENTER TOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.137196E+10 0.00 0.554214E+09 0.00 0.116290E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.123919E+10 0.00 0.644955E+10 0.00 0.123207E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.137196E+10 0.00 0.160395E+11 0.00 0.289482E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.132771E+10 0.00 0.225490E+11 0.00 0.403642E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.137196E+10 0.00 0.671348E+10 0.00 0.136699E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.132771E+10 0.00 0.133092E+11 0.00 0.281265E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.137196E+10 0.00 0.201270E+11 0.00 0.423508E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.137196E+10 0.00 0.263129E+11 0.00 0.546546E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.132771E+10 0.00 0.660866E+10 0.00 0.138260E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.137196E+10 0.00 0.106137E+11 0.00 0.199391E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.132771E+10 0.00 0.142141E+11 0.00 0.256814E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.137196E+10 0.00 0.185035E+11 0.00 0.325890E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.161538E+11 0.00 0.161995E+12 0.00 0.313633E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.123919E+10 0.00 0.554214E+09 0.00 0.116290E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.137196E+10 0.00 0.263129E+11 0.00 0.546546E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: BASEMENT

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.196203E+10 0.00 0.00 83350019.36 0.00 0.00 0.544355E+11 0.00 0.53
February 0.129227E+10 160508.21 0.00 74052461.95 0.00 0.00 0.479455E+11 0.00 0.71
March 0.394378E+09 71047628.40 0.00 88916541.93 1149650.78 0.00 0.545570E+11 0.00 1.04
April 0.253530E+09 0.218781E+09 0.00 71616292.72 10360870.10 0.00 0.356019E+11 0.00 1.01
May 91387161.73 0.193124E+10 0.00 61947500.99 24120620.56 0.00 0.232312E+11 0.00 1.01
June 47297180.55 0.130272E+11 0.00 28691896.89 0.110776E+09 0.00 0.667012E+10 0.00 0.57
July 29618387.59 0.190747E+11 0.00 15008267.32 0.297184E+09 0.00 0.225957E+10 0.00 0.38
August 447667.80 0.252666E+11 0.00 4946482.59 0.319443E+09 0.00 0.748234E+09 0.00 0.34
September 0.170106E+09 0.804081E+10 0.00 53465534.28 81830112.38 0.00 0.155312E+11 0.00 0.80
October 0.285193E+09 0.241727E+10 0.00 93417209.42 7594438.01 0.00 0.477011E+11 0.00 0.98
November 0.459315E+09 8775339.39 0.00 0.113803E+09 0.00 0.00 0.622954E+11 0.00 1.04
December 0.817741E+09 0.00 0.00 0.109692E+09 0.00 0.00 0.640033E+11 0.00 0.78
                   
Annual Sum or Average 0.580332E+10 0.700565E+11 0.00 0.798908E+09 0.852458E+09 0.00 0.414980E+12 0.00 0.76
Minimum of Months 447667.80 0.00 0.00 4946482.59 0.00 0.00 0.748234E+09 0.00 0.34
Maximum of Months 0.196203E+10 0.252666E+11 0.00 0.113803E+09 0.319443E+09 0.00 0.640033E+11 0.00 1.04



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: CORE_BOTTOM

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.776427E+10 0.00 0.00 42509964.42 0.00 0.00 0.297717E+11 0.00 0.39
February 0.491445E+10 0.00 0.00 51168421.51 0.00 0.00 0.323289E+11 0.00 0.54
March 0.606846E+10 48657856.24 0.00 79081877.42 1870606.05 0.00 0.427924E+11 0.00 0.84
April 0.833508E+10 0.242395E+09 0.00 65421207.11 11135598.33 0.00 0.281255E+11 0.00 0.92
May 0.233735E+10 0.125700E+10 0.00 44404533.36 97510145.83 0.00 0.128762E+11 0.00 0.67
June 0.164162E+10 0.578228E+10 0.00 13273874.11 0.492446E+09 0.00 0.392351E+10 0.00 0.43
July 0.249733E+09 0.820498E+10 0.00 2695860.30 0.914322E+09 0.00 0.303971E+09 0.00 0.28
August 0.114528E+09 0.110666E+11 0.00 1731985.65 0.934626E+09 0.00 0.213141E+09 0.00 0.29
September 0.123402E+10 0.413479E+10 0.00 31500111.82 0.515634E+09 0.00 0.915028E+10 0.00 0.54
October 0.296916E+10 0.147465E+10 0.00 63007856.83 0.122559E+09 0.00 0.329395E+11 0.00 0.67
November 0.429632E+10 5286676.20 0.00 78480160.33 0.00 0.00 0.434426E+11 0.00 0.75
December 0.403031E+10 0.00 0.00 77948736.47 0.00 0.00 0.454755E+11 0.00 0.59
                   
Annual Sum or Average 0.439553E+11 0.322166E+11 0.00 0.551225E+09 0.309010E+10 0.00 0.281343E+12 0.00 0.58
Minimum of Months 0.114528E+09 0.00 0.00 1731985.65 0.00 0.00 0.213141E+09 0.00 0.28
Maximum of Months 0.833508E+10 0.110666E+11 0.00 79081877.42 0.934626E+09 0.00 0.454755E+11 0.00 0.92



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: CORE_MID

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.218648E+12 0.00 0.00 30368959.25 0.00 0.561666E+09 0.392022E+11 0.00 0.32
February 0.153662E+12 0.00 0.00 0.134095E+09 0.00 15420990.23 0.963029E+11 0.00 0.40
March 0.744865E+11 0.344518E+09 0.00 0.441781E+09 0.120966E+09 0.00 0.262146E+12 0.00 0.60
April 0.288371E+11 0.212111E+10 0.00 0.455678E+09 0.184029E+09 0.00 0.206879E+12 0.00 0.64
May 0.149393E+11 0.114263E+11 0.00 0.366600E+09 0.107314E+10 0.00 0.109891E+12 0.00 0.58
June 0.653958E+10 0.561094E+11 0.00 0.122484E+09 0.475803E+10 0.00 0.346943E+11 0.00 0.38
July 0.120349E+10 0.784791E+11 0.00 18594469.58 0.976798E+10 0.00 0.219122E+10 0.00 0.26
August 0.370619E+09 0.105949E+12 0.00 17450028.08 0.982516E+10 0.00 0.204634E+10 0.00 0.28
September 0.112581E+11 0.401737E+11 0.00 0.249888E+09 0.495622E+10 0.00 0.726721E+11 0.00 0.47
October 0.414909E+11 0.132255E+11 0.00 0.357154E+09 0.123647E+10 0.00 0.210308E+12 0.00 0.50
November 0.804892E+11 0.106021E+09 0.00 0.331725E+09 0.431592E+09 0.00 0.219006E+12 0.00 0.50
December 0.153834E+12 0.00 0.00 0.149391E+09 0.00 0.00 0.127554E+12 0.00 0.37
                   
Annual Sum or Average 0.785759E+12 0.307935E+12 0.00 0.267521E+10 0.323536E+11 0.577087E+09 0.138289E+13 0.00 0.44
Minimum of Months 0.370619E+09 0.00 0.00 17450028.08 0.00 0.00 0.204634E+10 0.00 0.26
Maximum of Months 0.218648E+12 0.105949E+12 0.00 0.455678E+09 0.982516E+10 0.561666E+09 0.262146E+12 0.00 0.64



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: CORE_TOP

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.178008E+11 0.00 0.00 266625.71 0.00 0.226034E+10 0.423979E+09 0.00 0.31
February 0.166132E+11 0.00 0.00 3750696.07 0.00 0.839200E+09 0.278518E+10 0.00 0.38
March 0.134299E+11 11243283.35 0.00 22019513.24 10601958.48 8133894.12 0.135069E+11 0.00 0.53
April 0.632675E+10 0.101488E+09 0.00 34324912.51 13234236.99 0.00 0.135620E+11 0.00 0.61
May 0.192787E+10 0.109191E+10 0.00 33979075.82 0.100011E+09 0.00 0.910820E+10 0.00 0.60
June 0.829639E+09 0.558047E+10 0.00 10649565.40 0.512140E+09 0.00 0.282482E+10 0.00 0.38
July 0.132983E+09 0.767569E+10 0.00 1317115.84 0.107361E+10 0.00 0.125628E+09 0.00 0.26
August 28983600.34 0.104518E+11 0.00 1623655.17 0.984277E+09 0.00 0.160033E+09 0.00 0.28
September 0.193210E+10 0.380080E+10 0.00 19464652.61 0.611669E+09 0.00 0.511434E+10 0.00 0.45
October 0.943584E+10 0.128703E+10 0.00 16586538.54 0.126641E+09 4441741.47 0.101642E+11 0.00 0.45
November 0.164182E+11 0.00 0.00 7579555.66 95348672.10 0.201094E+09 0.578599E+10 0.00 0.42
December 0.191603E+11 0.00 0.00 2106994.95 0.00 0.840746E+09 0.188130E+10 0.00 0.34
                   
Annual Sum or Average 0.104037E+12 0.300005E+11 0.00 0.153669E+09 0.352754E+10 0.415395E+10 0.654425E+11 0.00 0.42
Minimum of Months 28983600.34 0.00 0.00 266625.71 0.00 0.00 0.125628E+09 0.00 0.26
Maximum of Months 0.191603E+11 0.104518E+11 0.00 34324912.51 0.107361E+10 0.226034E+10 0.135620E+11 0.00 0.61



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_BOT_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.324425E+10 0.00 0.00 309557.49 0.00 0.262095E+09 0.272503E+09 0.00 0.31
February 0.273986E+10 0.00 0.00 1283170.36 0.00 73888523.58 0.753325E+09 0.00 0.43
March 0.199943E+10 6897577.73 0.00 4566497.50 234795.29 0.00 0.264705E+10 0.00 0.69
April 0.156865E+10 36739434.62 0.00 5617441.15 1040927.55 0.00 0.227931E+10 0.00 0.86
May 0.421976E+09 0.218583E+09 0.00 4651637.54 8096163.75 0.00 0.132088E+10 0.00 0.72
June 0.228348E+09 0.112666E+10 0.00 1676886.67 30534725.75 0.00 0.469311E+09 0.00 0.56
July 32405178.26 0.162443E+10 0.00 305674.47 54609287.48 0.00 36045313.21 0.00 0.39
August 14464531.10 0.204916E+10 0.00 222087.72 43948716.77 0.00 26470112.05 0.00 0.40
September 0.288529E+09 0.648446E+09 0.00 2858901.47 58102255.40 0.00 0.832048E+09 0.00 0.56
October 0.139051E+10 0.206135E+09 0.00 3016365.20 15383342.91 0.00 0.183290E+10 0.00 0.53
November 0.208118E+10 0.00 0.00 3214864.84 429884.11 0.00 0.201518E+10 0.00 0.54
December 0.303766E+10 0.00 0.00 1363521.00 0.00 0.00 0.104657E+10 0.00 0.40
                   
Annual Sum or Average 0.170473E+11 0.591705E+10 0.00 29086605.42 0.212380E+09 0.335984E+09 0.135316E+11 0.00 0.53
Minimum of Months 14464531.10 0.00 0.00 222087.72 0.00 0.00 26470112.05 0.00 0.31
Maximum of Months 0.324425E+10 0.204916E+10 0.00 5617441.15 58102255.40 0.262095E+09 0.264705E+10 0.00 0.86



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_BOT_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.233432E+10 0.00 0.00 308530.79 0.00 0.215453E+09 0.275652E+09 0.00 0.36
February 0.190180E+10 0.00 0.00 1529032.54 0.00 54225597.71 0.973272E+09 0.00 0.54
March 0.148025E+10 4602911.42 0.00 4203539.91 175645.49 0.00 0.246153E+10 0.00 0.86
April 0.124183E+10 24582025.40 0.00 5403249.85 804303.65 0.00 0.218524E+10 0.00 1.15
May 0.336156E+09 0.182840E+09 0.00 4570167.73 5031539.21 0.00 0.133235E+10 0.00 1.01
June 0.179442E+09 0.867688E+09 0.00 1775362.51 34500725.12 0.00 0.511690E+09 0.00 0.73
July 30865761.64 0.127509E+10 0.00 137189.80 49460193.29 0.00 17869477.03 0.00 0.47
August 11061304.66 0.148000E+10 0.00 157819.95 52194201.58 0.00 19514898.83 0.00 0.46
September 0.289097E+09 0.534455E+09 0.00 2776042.52 40480908.06 0.00 0.741288E+09 0.00 0.76
October 0.993791E+09 0.139964E+09 0.00 3310421.29 11507959.87 0.00 0.192931E+10 0.00 0.71
November 0.155913E+10 0.00 0.00 2469807.15 321587.39 0.00 0.161290E+10 0.00 0.63
December 0.220021E+10 0.00 0.00 1023285.15 0.00 683824.64 0.872808E+09 0.00 0.45
                   
Annual Sum or Average 0.125580E+11 0.450922E+10 0.00 27664449.19 0.194477E+09 0.270363E+09 0.129334E+11 0.00 0.68
Minimum of Months 11061304.66 0.00 0.00 137189.80 0.00 0.00 17869477.03 0.00 0.36
Maximum of Months 0.233432E+10 0.148000E+10 0.00 5403249.85 52194201.58 0.215453E+09 0.246153E+10 0.00 1.15



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_BOT_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.224029E+10 0.00 0.00 3256787.80 0.00 0.301324E+09 0.247673E+10 0.00 0.41
February 0.198306E+10 0.00 0.00 5091473.28 0.00 0.103942E+09 0.293852E+10 0.00 0.64
March 0.157192E+10 14095522.01 0.00 8998601.60 35347.72 0.00 0.487714E+10 0.00 1.01
April 0.152319E+10 46344356.95 0.00 7819294.92 927445.03 0.00 0.294993E+10 0.00 1.08
May 0.436513E+09 0.250757E+09 0.00 4932268.01 6565922.77 0.00 0.135698E+10 0.00 0.78
June 0.271769E+09 0.114605E+10 0.00 1565975.63 28009696.95 0.00 0.390476E+09 0.00 0.56
July 30995817.54 0.167232E+10 0.00 281734.25 58481568.99 0.00 35727896.43 0.00 0.40
August 13775763.98 0.232947E+10 0.00 242104.48 38907871.93 0.00 28486532.69 0.00 0.46
September 0.323827E+09 0.853438E+09 0.00 4204084.46 45267233.87 0.00 0.102018E+10 0.00 0.75
October 0.109804E+10 0.280416E+09 0.00 8215204.86 13556139.43 0.00 0.418620E+10 0.00 0.91
November 0.143868E+10 0.00 0.00 9586465.70 428808.07 0.00 0.510039E+10 0.00 0.91
December 0.203275E+10 0.00 0.00 6570475.80 0.00 12364517.32 0.454123E+10 0.00 0.66
                   
Annual Sum or Average 0.129648E+11 0.659289E+10 0.00 60764470.77 0.192180E+09 0.417630E+09 0.299020E+11 0.00 0.71
Minimum of Months 13775763.98 0.00 0.00 242104.48 0.00 0.00 28486532.69 0.00 0.40
Maximum of Months 0.224029E+10 0.232947E+10 0.00 9586465.70 58481568.99 0.301324E+09 0.510039E+10 0.00 1.08



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_BOT_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.279635E+10 0.00 0.00 1110542.28 0.00 14838384.95 0.102902E+10 0.00 0.50
February 0.166585E+10 0.00 0.00 3994208.11 0.00 0.00 0.241403E+10 0.00 0.79
March 0.433496E+09 14643477.71 0.00 12258300.26 27265.19 0.00 0.619807E+10 0.00 1.58
April 0.510636E+09 55602669.78 0.00 14342107.93 400210.60 0.00 0.521494E+10 0.00 2.03
May 0.220748E+09 0.234703E+09 0.00 6360093.76 1969341.30 0.00 0.173785E+10 0.00 1.27
June 0.117705E+09 0.122785E+10 0.00 2695443.78 9702262.39 0.00 0.682168E+09 0.00 0.99
July 6679394.49 0.190851E+10 0.00 733487.53 19731359.76 0.00 78728219.39 0.00 0.71
August 1813914.24 0.263675E+10 0.00 513181.21 6155021.01 0.00 55103446.78 0.00 0.79
September 0.133359E+09 0.732360E+09 0.00 3978134.95 19654005.11 0.00 0.105720E+10 0.00 0.97
October 0.366612E+09 0.241409E+09 0.00 7436173.30 2453621.37 0.00 0.382955E+10 0.00 1.10
November 0.615649E+09 603113.34 0.00 8965682.71 0.00 0.00 0.499334E+10 0.00 1.19
December 0.689740E+09 0.00 0.00 7731507.26 0.00 0.00 0.509228E+10 0.00 0.91
                   
Annual Sum or Average 0.755864E+10 0.705243E+10 0.00 70118863.08 60093086.74 14838384.95 0.323823E+11 0.00 1.07
Minimum of Months 1813914.24 0.00 0.00 513181.21 0.00 0.00 55103446.78 0.00 0.50
Maximum of Months 0.279635E+10 0.263675E+10 0.00 14342107.93 19731359.76 14838384.95 0.619807E+10 0.00 2.03



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_MID_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.138085E+11 0.00 0.00 0.00 0.00 0.191903E+11 0.00 0.00 0.32
February 0.193891E+11 0.00 0.00 1604247.12 0.00 0.103056E+11 0.497640E+09 0.00 0.38
March 0.279788E+11 36051401.96 0.00 12721378.21 28667034.50 0.400639E+09 0.649624E+10 0.00 0.51
April 0.145844E+11 0.305238E+09 0.00 27276852.49 18548665.79 3875395.17 0.965081E+10 0.00 0.58
May 0.514419E+10 0.197272E+10 0.00 32688375.35 0.122544E+09 0.00 0.865575E+10 0.00 0.61
June 0.154566E+10 0.112709E+11 0.00 14039037.46 0.476201E+09 0.00 0.345236E+10 0.00 0.52
July 0.253080E+09 0.163144E+11 0.00 1625681.58 0.842073E+09 0.00 0.188634E+09 0.00 0.40
August 51053575.57 0.203823E+11 0.00 1801542.18 0.922924E+09 0.00 0.235458E+09 0.00 0.41
September 0.434195E+10 0.618139E+10 0.00 19455546.56 0.621850E+09 0.00 0.468872E+10 0.00 0.48
October 0.212341E+11 0.173824E+10 0.00 7121107.38 0.180657E+09 0.163707E+09 0.416575E+10 0.00 0.42
November 0.284374E+11 0.00 0.00 2282551.11 67539492.57 0.198756E+10 0.168111E+10 0.00 0.42
December 0.248502E+11 0.00 0.00 760537.62 0.00 0.868129E+10 0.453836E+09 0.00 0.35
                   
Annual Sum or Average 0.161618E+12 0.582013E+11 0.00 0.121377E+09 0.328100E+10 0.407330E+11 0.401663E+11 0.00 0.45
Minimum of Months 51053575.57 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.32
Maximum of Months 0.284374E+11 0.203823E+11 0.00 32688375.35 0.922924E+09 0.191903E+11 0.965081E+10 0.00 0.61



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_MID_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.146199E+11 0.00 0.00 0.00 0.00 0.112204E+11 0.00 0.00 0.39
February 0.147382E+11 0.00 0.00 6777179.87 0.00 0.575320E+10 0.431584E+10 0.00 0.49
March 0.162944E+11 46164007.07 0.00 25486427.17 3017138.67 0.173591E+09 0.144805E+11 0.00 0.70
April 0.751586E+10 0.266515E+09 0.00 46126755.98 11964113.68 3151362.43 0.180565E+11 0.00 0.95
May 0.320596E+10 0.180517E+10 0.00 40919946.41 91487362.69 0.00 0.115983E+11 0.00 0.96
June 0.923393E+09 0.978376E+10 0.00 19150217.37 0.351491E+09 0.00 0.514979E+10 0.00 0.76
July 0.199981E+09 0.149763E+11 0.00 1321277.32 0.613656E+09 0.00 0.167888E+09 0.00 0.55
August 40151120.35 0.177276E+11 0.00 1943990.61 0.606662E+09 0.00 0.240366E+09 0.00 0.57
September 0.336477E+10 0.573289E+10 0.00 24018246.92 0.436001E+09 0.00 0.597081E+10 0.00 0.73
October 0.125267E+11 0.134334E+10 0.00 20326045.56 0.153130E+09 0.136171E+09 0.118012E+11 0.00 0.62
November 0.209137E+11 0.00 0.00 5669253.42 53295812.91 0.611881E+09 0.429702E+10 0.00 0.53
December 0.223778E+11 0.00 0.00 274652.33 0.00 0.409760E+10 0.285280E+09 0.00 0.43
                   
Annual Sum or Average 0.116721E+12 0.516817E+11 0.00 0.192014E+09 0.232070E+10 0.219960E+11 0.763636E+11 0.00 0.64
Minimum of Months 40151120.35 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.39
Maximum of Months 0.223778E+11 0.177276E+11 0.00 46126755.98 0.613656E+09 0.112204E+11 0.180565E+11 0.00 0.96



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_MID_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.167400E+11 0.00 0.00 24092382.41 0.00 0.754955E+10 0.166686E+11 0.00 0.39
February 0.167719E+11 0.00 0.00 37854791.66 0.00 0.378977E+10 0.207131E+11 0.00 0.57
March 0.155252E+11 0.144090E+09 0.00 67012236.60 1159292.67 0.144512E+09 0.354238E+11 0.00 0.83
April 0.106799E+11 0.476756E+09 0.00 57959433.38 13950985.03 0.00 0.201810E+11 0.00 0.83
May 0.487117E+10 0.236323E+10 0.00 39717833.75 0.107472E+09 0.00 0.101098E+11 0.00 0.70
June 0.164879E+10 0.115029E+11 0.00 13838306.93 0.472066E+09 0.00 0.325796E+10 0.00 0.53
July 0.249953E+09 0.171808E+11 0.00 1620544.56 0.750382E+09 0.00 0.189795E+09 0.00 0.41
August 46414009.78 0.244617E+11 0.00 2248730.69 0.694823E+09 0.00 0.265778E+09 0.00 0.50
September 0.364755E+10 0.887310E+10 0.00 38294972.40 0.465012E+09 0.00 0.817474E+10 0.00 0.71
October 0.116605E+11 0.274667E+10 0.00 69328337.22 0.147961E+09 0.00 0.335202E+11 0.00 0.82
November 0.143787E+11 0.00 0.00 74136327.15 67516373.45 0.544380E+09 0.377263E+11 0.00 0.75
December 0.187217E+11 0.00 0.00 43628427.54 0.00 0.287110E+10 0.289135E+11 0.00 0.54
                   
Annual Sum or Average 0.114942E+12 0.677492E+11 0.00 0.469732E+09 0.272034E+10 0.148993E+11 0.215145E+12 0.00 0.63
Minimum of Months 46414009.78 0.00 0.00 1620544.56 0.00 0.00 0.189795E+09 0.00 0.39
Maximum of Months 0.187217E+11 0.244617E+11 0.00 74136327.15 0.750382E+09 0.754955E+10 0.377263E+11 0.00 0.83



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_MID_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.172722E+11 0.00 0.00 431187.75 0.00 0.908878E+10 0.724534E+09 0.00 0.41
February 0.184831E+11 0.00 0.00 6668758.11 0.00 0.395426E+10 0.334547E+10 0.00 0.52
March 0.176143E+11 0.118442E+09 0.00 29554779.38 904954.52 3057286.86 0.156938E+11 0.00 0.82
April 0.813075E+10 0.395552E+09 0.00 47952937.72 8270667.14 0.00 0.162953E+11 0.00 1.01
May 0.313583E+10 0.195920E+10 0.00 38501938.92 28315103.44 0.00 0.100218E+11 0.00 0.96
June 0.859370E+09 0.102506E+11 0.00 15356314.03 0.195103E+09 0.00 0.356877E+10 0.00 0.76
July 0.133696E+09 0.150625E+11 0.00 2228859.91 0.408742E+09 0.00 0.270547E+09 0.00 0.57
August 35354590.44 0.201062E+11 0.00 1882230.83 0.241486E+09 0.00 0.228906E+09 0.00 0.62
September 0.314572E+10 0.610447E+10 0.00 23037896.32 0.340233E+09 0.00 0.490399E+10 0.00 0.74
October 0.137389E+11 0.159898E+10 0.00 21097739.87 0.129080E+09 0.00 0.106523E+11 0.00 0.66
November 0.211416E+11 0.00 0.00 11568910.95 56123509.08 0.582739E+09 0.661871E+10 0.00 0.60
December 0.228556E+11 0.00 0.00 3106791.32 0.00 0.336095E+10 0.215326E+10 0.00 0.45
                   
Annual Sum or Average 0.126546E+12 0.555959E+11 0.00 0.201388E+09 0.140826E+10 0.169898E+11 0.744774E+11 0.00 0.68
Minimum of Months 35354590.44 0.00 0.00 431187.75 0.00 0.00 0.228906E+09 0.00 0.41
Maximum of Months 0.228556E+11 0.201062E+11 0.00 47952937.72 0.408742E+09 0.908878E+10 0.162953E+11 0.00 1.01



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_TOP_ZN_3

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.630072E+09 0.00 0.00 0.00 0.00 0.213506E+10 0.00 0.00 0.34
February 0.129280E+10 0.00 0.00 67850.83 0.00 0.129841E+10 21453597.11 0.00 0.38
March 0.240681E+10 979240.51 0.00 1057617.28 1974212.45 0.346255E+09 0.456934E+09 0.00 0.50
April 0.144739E+10 13848402.75 0.00 2670440.65 1647460.27 63452227.51 0.749880E+09 0.00 0.58
May 0.554926E+09 0.182674E+09 0.00 3348670.24 12669835.75 0.00 0.723638E+09 0.00 0.64
June 0.155271E+09 0.109643E+10 0.00 1320620.04 39718288.77 0.00 0.304069E+09 0.00 0.51
July 18816647.86 0.156965E+10 0.00 144753.98 79784005.97 0.00 14523937.71 0.00 0.39
August 4101415.55 0.197498E+10 0.00 168293.58 80177304.06 0.00 19321648.46 0.00 0.40
September 0.438035E+09 0.589200E+09 0.00 1686646.84 65078271.72 0.00 0.381484E+09 0.00 0.47
October 0.185571E+10 0.165670E+09 0.00 421735.00 19628212.82 0.199543E+09 0.228370E+09 0.00 0.42
November 0.211658E+10 0.00 6078449.67 98285.36 5888221.09 0.613255E+09 52690597.81 11172.53 0.41
December 0.123181E+10 0.00 0.00 17142.99 0.00 0.156880E+10 24698179.06 0.00 0.35
                   
Annual Sum or Average 0.121523E+11 0.559343E+10 6078449.67 11002056.79 0.306566E+09 0.622478E+10 0.297706E+10 11172.53 0.45
Minimum of Months 4101415.55 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.34
Maximum of Months 0.240681E+10 0.197498E+10 6078449.67 3348670.24 80177304.06 0.213506E+10 0.749880E+09 11172.53 0.64



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_TOP_ZN_2

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.839590E+09 0.00 0.00 0.00 0.00 0.127083E+10 0.00 0.00 0.39
February 0.103607E+10 0.00 0.00 379114.83 0.00 0.782800E+09 0.233542E+09 0.00 0.47
March 0.146801E+10 1264627.06 0.00 1881567.79 1054053.41 0.159743E+09 0.107060E+10 0.00 0.66
April 0.696647E+09 13185697.76 0.00 4577294.32 729973.44 31786085.88 0.156258E+10 0.00 0.94
May 0.294515E+09 0.174572E+09 0.00 4379133.00 6561504.62 0.00 0.108987E+10 0.00 1.02
June 84772953.11 0.970148E+09 0.00 1884235.65 27456443.97 0.00 0.490520E+09 0.00 0.77
July 14794546.16 0.145471E+10 0.00 122932.88 65407564.32 0.00 12572083.64 0.00 0.55
August 4719244.53 0.174072E+10 0.00 212224.75 52536667.31 0.00 19513440.69 0.00 0.57
September 0.304220E+09 0.565217E+09 0.00 2347330.28 45445788.81 0.00 0.570226E+09 0.00 0.74
October 0.114227E+10 0.133388E+09 0.00 1573643.85 16322790.52 0.107275E+09 0.843776E+09 0.00 0.60
November 0.171709E+10 0.00 4815479.73 264353.52 4660115.15 0.282337E+09 0.200845E+09 4030.32 0.51
December 0.132642E+10 0.00 0.00 7184.02 0.00 0.852823E+09 19553264.73 0.00 0.42
                   
Annual Sum or Average 0.892912E+10 0.505321E+10 4815479.73 17629014.90 0.220175E+09 0.348759E+10 0.611360E+10 4030.32 0.64
Minimum of Months 4719244.53 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.39
Maximum of Months 0.171709E+10 0.174072E+10 4815479.73 4577294.32 65407564.32 0.127083E+10 0.156258E+10 4030.32 1.02



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_TOP_ZN_1

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.119740E+10 0.00 0.00 1172043.86 0.00 0.950701E+09 0.840381E+09 0.00 0.35
February 0.123496E+10 0.00 0.00 2555239.36 0.00 0.657788E+09 0.142202E+10 0.00 0.52
March 0.156187E+10 6328477.71 0.00 5282726.03 89518.41 0.170915E+09 0.270609E+10 0.00 0.75
April 0.104119E+10 22753050.63 0.00 5894723.20 883707.70 41464795.19 0.178409E+10 0.00 0.81
May 0.498417E+09 0.218649E+09 0.00 4217101.67 9064562.82 0.00 0.918954E+09 0.00 0.74
June 0.178096E+09 0.111407E+10 0.00 1344670.90 39457066.91 0.00 0.287653E+09 0.00 0.52
July 18591956.34 0.163831E+10 0.00 145814.16 75235428.06 0.00 14835381.11 0.00 0.40
August 3724130.94 0.235805E+10 0.00 239744.60 51328521.74 0.00 22055434.82 0.00 0.48
September 0.369442E+09 0.840040E+09 0.00 3712027.75 43873717.33 0.00 0.769293E+09 0.00 0.71
October 0.102664E+10 0.259752E+09 0.00 5586127.40 17328855.11 0.113997E+09 0.277509E+10 0.00 0.76
November 0.148990E+10 0.00 0.00 4595799.97 11993975.50 0.200713E+09 0.240926E+10 0.00 0.65
December 0.144907E+10 0.00 0.00 2426587.06 0.00 0.519082E+09 0.156205E+10 0.00 0.44
                   
Annual Sum or Average 0.100693E+11 0.645795E+10 0.00 37172605.96 0.249255E+09 0.265466E+10 0.155118E+11 0.00 0.59
Minimum of Months 3724130.94 0.00 0.00 145814.16 0.00 0.00 14835381.11 0.00 0.35
Maximum of Months 0.156187E+10 0.235805E+10 0.00 5894723.20 75235428.06 0.950701E+09 0.277509E+10 0.00 0.81



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_TOP_ZN_4

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.110287E+10 0.00 0.00 10880.19 0.00 0.119591E+10 18660897.51 0.00 0.44
February 0.139031E+10 0.00 0.00 458901.95 0.00 0.695059E+09 0.235941E+09 0.00 0.54
March 0.187130E+10 4438446.93 0.00 2464129.78 293972.91 0.124435E+09 0.118366E+10 0.00 0.81
April 0.940210E+09 20038663.21 0.00 4793757.15 523164.15 19077432.96 0.141233E+10 0.00 1.02
May 0.385432E+09 0.177762E+09 0.00 3972623.26 4531873.28 0.00 0.910273E+09 0.00 1.01
June 0.103142E+09 0.963680E+09 0.00 1502861.18 20164831.56 0.00 0.327108E+09 0.00 0.74
July 11506021.26 0.140577E+10 0.00 214309.45 47959002.71 0.00 19755301.66 0.00 0.54
August 3135813.48 0.190402E+10 0.00 191070.68 20830231.50 0.00 18163864.94 0.00 0.59
September 0.350405E+09 0.578424E+09 0.00 2141779.76 36691099.63 0.00 0.425717E+09 0.00 0.74
October 0.144022E+10 0.150675E+09 0.00 1527361.02 17645806.35 65660399.00 0.772566E+09 0.00 0.66
November 0.184075E+10 0.00 0.00 689077.07 10628803.15 0.283060E+09 0.429056E+09 0.00 0.60
December 0.168096E+10 0.00 0.00 113266.12 0.00 0.655235E+09 0.103137E+09 0.00 0.47
                   
Annual Sum or Average 0.111202E+11 0.520481E+10 0.00 18080017.59 0.159269E+09 0.303843E+10 0.585637E+10 0.00 0.68
Minimum of Months 3135813.48 0.00 0.00 10880.19 0.00 0.00 18163864.94 0.00 0.44
Maximum of Months 0.187130E+10 0.190402E+10 0.00 4793757.15 47959002.71 0.119591E+10 0.141233E+10 0.00 1.02



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: DATACENTER_BOT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.00 0.00 0.00 2742252.08 0.00 0.00 0.592323E+09 0.00 0.28
February 0.00 0.00 0.00 6980699.02 0.00 0.00 0.444605E+09 0.00 0.28
March 0.00 5269198.72 0.00 11995131.49 0.00 0.00 0.338260E+09 0.00 0.31
April 0.00 12994567.02 0.00 14122304.37 0.00 0.00 0.181712E+09 0.00 0.29
May 0.00 68533457.61 0.00 1353759.84 0.00 0.00 58524303.60 0.00 0.29
June 0.00 0.285331E+09 0.00 1309164.15 0.00 0.00 26613528.29 0.00 0.30
July 0.00 0.402199E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.28
August 0.00 0.499320E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.31
September 0.00 0.158494E+09 0.00 1212224.80 0.00 0.00 32733749.17 0.00 0.29
October 0.00 52348305.75 0.00 5991202.21 0.00 0.00 0.239052E+09 0.00 0.28
November 0.00 4289461.37 0.00 10904613.36 0.00 0.00 0.353738E+09 0.00 0.28
December 0.00 726617.79 0.00 16223923.69 0.00 0.00 0.447575E+09 0.00 0.28
                   
Annual Sum or Average 0.00 0.148951E+10 0.00 72835275.02 0.00 0.00 0.271514E+10 0.00 0.29
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.28
Maximum of Months 0.00 0.499320E+09 0.00 16223923.69 0.00 0.00 0.592323E+09 0.00 0.31



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: DATACENTER_MID_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.921393E+09 0.00 0.00 10447566.28 0.00 0.00 0.502837E+10 0.00 0.28
February 0.00 0.00 0.00 55021873.60 0.00 0.00 0.446352E+10 0.00 0.28
March 0.00 52152447.41 0.00 0.109096E+09 0.00 0.00 0.338955E+10 0.00 0.31
April 0.00 0.130235E+09 0.00 0.133194E+09 0.00 0.00 0.182135E+10 0.00 0.29
May 0.00 0.660742E+09 0.00 12659580.97 0.00 0.00 0.590626E+09 0.00 0.29
June 0.00 0.284124E+10 0.00 12294156.64 0.00 0.00 0.266036E+09 0.00 0.30
July 0.00 0.401574E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.28
August 0.00 0.498209E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.31
September 0.00 0.155511E+10 0.00 10796318.06 0.00 0.00 0.337807E+09 0.00 0.29
October 0.00 0.517095E+09 0.00 52582543.47 0.00 0.00 0.239901E+10 0.00 0.28
November 0.00 41614626.12 0.00 96787918.75 0.00 0.00 0.354705E+10 0.00 0.28
December 0.00 7146179.47 0.00 0.141642E+09 0.00 0.00 0.449361E+10 0.00 0.28
                   
Annual Sum or Average 0.921393E+09 0.148032E+11 0.00 0.634521E+09 0.00 0.00 0.263369E+11 0.00 0.29
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.28
Maximum of Months 0.921393E+09 0.498209E+10 0.00 0.141642E+09 0.00 0.00 0.502837E+10 0.00 0.31



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: DATACENTER_TOP_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.378980E+09 0.00 0.00 403018.03 0.00 0.00 0.207136E+09 0.00 0.28
February 0.00 0.00 0.00 4636950.32 0.00 0.00 0.447616E+09 0.00 0.28
March 0.00 5203960.68 0.00 10244982.27 0.00 0.00 0.339951E+09 0.00 0.31
April 0.00 12952956.65 0.00 13058356.51 0.00 0.00 0.182620E+09 0.00 0.29
May 0.00 66811597.78 0.00 1193376.79 0.00 0.00 59256295.74 0.00 0.29
June 0.00 0.284445E+09 0.00 1218431.00 0.00 0.00 26655222.57 0.00 0.30
July 0.00 0.401449E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.28
August 0.00 0.498409E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.31
September 0.00 0.155576E+09 0.00 1002010.06 0.00 0.00 34686379.67 0.00 0.29
October 0.00 51503511.38 0.00 4730961.12 0.00 0.00 0.241275E+09 0.00 0.28
November 0.00 4040854.42 0.00 8801618.97 0.00 0.00 0.355927E+09 0.00 0.28
December 0.00 693066.40 0.00 13019015.75 0.00 0.00 0.450751E+09 0.00 0.28
                   
Annual Sum or Average 0.378980E+09 0.148109E+10 0.00 58308720.81 0.00 0.00 0.234587E+10 0.00 0.29
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.28
Maximum of Months 0.378980E+09 0.498409E+09 0.00 13058356.51 0.00 0.00 0.450751E+09 0.00 0.31



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: DATACENTER_BASEMENT_ZN_6

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                   
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: HeatEmissionsReportMonthly

For: Environment

Timestamp: 2023-10-16 09:05:17

Custom Monthly Report

SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J]
January 0.348884E+12 0.775465E+10 0.00 0.154379E+13 0.102739E+12
February 0.350620E+12 0.698562E+10 0.00 0.153966E+13 0.230522E+12
March 0.513827E+12 0.443854E+10 0.00 0.168276E+13 0.512062E+12
April 0.576839E+12 0.226335E+10 0.00 0.133414E+13 0.881417E+12
May 0.635926E+12 0.102321E+10 0.00 0.779459E+12 0.113680E+13
June 0.618355E+12 -0.130151E+10 0.00 -0.344719E+10 0.185381E+13
July 0.596203E+12 -0.254255E+10 0.00 -0.408290E+12 0.216601E+13
August 0.554242E+12 -0.330204E+10 0.00 -0.547723E+12 0.245030E+13
September 0.428126E+12 -301153720.9 0.00 0.304157E+12 0.132935E+13
October 0.407108E+12 0.220000E+10 0.00 0.129176E+13 0.681979E+12
November 0.299590E+12 0.378999E+10 0.00 0.158441E+13 0.408013E+12
December 0.285234E+12 0.737052E+10 0.00 0.168083E+13 0.343924E+12
           
Annual Sum or Average 0.561495E+13 0.283786E+11 0.00 0.107815E+14 0.120969E+14
Minimum of Months 0.285234E+12 -0.330204E+10 0.00 -0.547723E+12 0.102739E+12
Maximum of Months 0.635926E+12 0.775465E+10 0.00 0.168276E+13 0.245030E+13