Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:41
Tabular Output Report in Format: HTML
Building: RetailStripmall
Environment: RUNPERIOD 1 ** International Falls Intl Ap MN USA TMY3 WMO#=727470
Simulation Timestamp: 2023-10-16 08:41:09
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1859.70 | 889.67 | 889.67 |
Net Site Energy | 1859.70 | 889.67 | 889.67 |
Total Source Energy | 3918.85 | 1874.76 | 1874.76 |
Net Source Energy | 3918.85 | 1874.76 | 1874.76 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 1.200 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil No 1 | 1.050 |
Fuel Oil No 2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2090.32 |
Net Conditioned Building Area | 2090.32 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 946.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 56.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 441.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 100.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 128.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 109.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 9.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 67.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 913.55 | 946.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 946.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 56.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 441.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 100.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 128.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 109.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 9.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 67.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Unassigned | 0.00 | 946.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | Unassigned | 56.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GENERAL | 441.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | Unassigned | 100.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | GENERAL | 128.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Unassigned | 109.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | Unassigned | 9.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Unassigned | 67.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 259.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 112.00 | 452.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
Other | 65.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 437.04 | 452.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 259.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 112.00 | 452.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
Other | 65.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 437.04 | 452.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 913.552 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 913.552 | 100.00 |
Total On-Site and Utility Electric Sources | 913.552 | 100.00 |
Total Electricity End Uses | 913.552 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | 0.00 |
Air to Air Heat Recovery for Cooling | 7.60 | 4.07 |
Air to Air Heat Recovery for Heating | 179.25 | 95.93 |
High-Temperature Geothermal* | 0.00 | 0.00 |
Solar Water Thermal | 0.00 | 0.00 |
Solar Air Thermal | 0.00 | 0.00 |
Total On-Site Thermal Sources | 186.85 | 100.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 87.30 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 87.30 | 100.00 |
Total Water End Uses | 87.30 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 0.17 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 3193.00 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTRIPMALL
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 7
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MN_INTERNATIONALFALLS
| Environment |ZoneCoolingSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ZoneHeatingSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ZoneElectricSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |SpaceGainsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |PeakSpaceGainsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |SpaceGainComponentsAtCoolingPeakMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ComfortReportSimple55Monthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |OccupantComfortDataSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |DXReportMonthly
| PSZ-AC_1:1 COOLING COIL | PSZ-AC_2:2 COOLING COIL | PSZ-AC_3:3 COOLING COIL | PSZ-AC_4:4 COOLING COIL | PSZ-AC_5:5 COOLING COIL | PSZ-AC_6:6 COOLING COIL | PSZ-AC_7:7 COOLING COIL | PSZ-AC_8:8 COOLING COIL | PSZ-AC_9:9 COOLING COIL | PSZ-AC_10:10 COOLING COIL |WindowReportMonthly
| LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR |WindowEnergyReportMonthly
| LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR |WindowZoneSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |WindowEnergyZoneSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK1 | GAS TANK2 | GAS TANK3 | GAS TANK4 | GAS TANK5 | GAS TANK6 | GAS TANK7 |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC_1:1 HEATING COIL | PSZ-AC_2:2 HEATING COIL | PSZ-AC_3:3 HEATING COIL | PSZ-AC_4:4 HEATING COIL | PSZ-AC_5:5 HEATING COIL | PSZ-AC_6:6 HEATING COIL | PSZ-AC_7:7 HEATING COIL | PSZ-AC_8:8 HEATING COIL | PSZ-AC_9:9 HEATING COIL | PSZ-AC_10:10 HEATING COIL | PSZ-AC_1:1 COOLING COIL | PSZ-AC_2:2 COOLING COIL | PSZ-AC_3:3 COOLING COIL | PSZ-AC_4:4 COOLING COIL | PSZ-AC_5:5 COOLING COIL | PSZ-AC_6:6 COOLING COIL | PSZ-AC_7:7 COOLING COIL | PSZ-AC_8:8 COOLING COIL | PSZ-AC_9:9 COOLING COIL | PSZ-AC_10:10 COOLING COIL |FanReportMonthly
| PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |MechanicalVentilationLoadsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
GeneralValue | |
Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:41 |
RunPeriod | RUNPERIOD 1 |
Weather File | International Falls Intl Ap MN USA TMY3 WMO#=727470 |
Latitude [deg] | 48.57 |
Longitude [deg] | -93.4 |
Elevation [m] | 359.00 |
Time Zone | -6.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Above Ground Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Window Opening Area [m2] | 124.40 | 0.00 | 0.00 | 124.40 | 0.00 |
Gross Window-Wall Ratio [%] | 10.51 | 0.00 | 0.00 | 26.26 | 0.00 |
Above Ground Window-Wall Ratio [%] | 10.51 | 0.00 | 0.00 | 26.26 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Above Ground Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Window Opening Area [m2] | 124.40 | 0.00 | 0.00 | 124.40 | 0.00 |
Gross Window-Wall Ratio [%] | 10.51 | 0.00 | 0.00 | 26.26 | 0.00 |
Above Ground Window-Wall Ratio [%] | 10.51 | 0.00 | 0.00 | 26.26 | 0.00 |
Total | |
Gross Roof Area [m2] | 2090.32 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
LGSTORE1 | 348.39 | Yes | Yes | 1805.20 | 1.00 | 276.30 | 0.00 | 20.77 | 20.77 | 17.8770 | 6.19 | 4.3000 |
SMSTORE1 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.38 | 10.38 | 19.3382 | 6.19 | 4.3000 |
SMSTORE2 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.36 | 10.36 | 17.3739 | 6.19 | 4.3000 |
SMSTORE3 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.36 | 10.36 | 17.3739 | 6.19 | 4.3000 |
SMSTORE4 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.36 | 10.36 | 17.3739 | 6.19 | 4.3000 |
LGSTORE2 | 348.39 | Yes | Yes | 1805.20 | 1.00 | 157.89 | 0.00 | 20.72 | 20.72 | 13.1675 | 6.19 | 4.3000 |
SMSTORE5 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.36 | 10.36 | 13.3365 | 6.19 | 4.3000 |
SMSTORE6 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.36 | 10.36 | 13.3365 | 6.19 | 4.3000 |
SMSTORE7 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.36 | 10.36 | 13.3365 | 6.19 | 4.3000 |
SMSTORE8 | 174.19 | Yes | Yes | 902.60 | 1.00 | 197.36 | 0.00 | 10.36 | 10.36 | 13.3365 | 6.19 | 4.3000 |
Total | 2090.32 | 10831.20 | 1184.15 | 0.00 | 124.40 | 124.40 | 15.5746 | 6.19 | 4.3000 | |||
Conditioned Total | 2090.32 | 10831.20 | 1184.15 | 0.00 | 124.40 | 124.40 | 15.5746 | 6.19 | 4.3000 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
LGSTORE1 | 348.39 | Yes | Yes | 1.00 | LGSTORE1 | GENERAL | LGSTORE1 | 17.8770 | 6.19 | 4.3000 | |
SMSTORE1 | 174.19 | Yes | Yes | 1.00 | SMSTORE1 | GENERAL | SMSTORE1 | 19.3382 | 6.19 | 4.3000 | |
SMSTORE2 | 174.19 | Yes | Yes | 1.00 | SMSTORE2 | GENERAL | SMSTORE2 | 17.3739 | 6.19 | 4.3000 | |
SMSTORE3 | 174.19 | Yes | Yes | 1.00 | SMSTORE3 | GENERAL | SMSTORE3 | 17.3739 | 6.19 | 4.3000 | |
SMSTORE4 | 174.19 | Yes | Yes | 1.00 | SMSTORE4 | GENERAL | SMSTORE4 | 17.3739 | 6.19 | 4.3000 | |
LGSTORE2 | 348.39 | Yes | Yes | 1.00 | LGSTORE2 | GENERAL | LGSTORE2 | 13.1675 | 6.19 | 4.3000 | |
SMSTORE5 | 174.19 | Yes | Yes | 1.00 | SMSTORE5 | GENERAL | SMSTORE5 | 13.3365 | 6.19 | 4.3000 | |
SMSTORE6 | 174.19 | Yes | Yes | 1.00 | SMSTORE6 | GENERAL | SMSTORE6 | 13.3365 | 6.19 | 4.3000 | |
SMSTORE7 | 174.19 | Yes | Yes | 1.00 | SMSTORE7 | GENERAL | SMSTORE7 | 13.3365 | 6.19 | 4.3000 | |
SMSTORE8 | 174.19 | Yes | Yes | 1.00 | SMSTORE8 | GENERAL | SMSTORE8 | 13.3365 | 6.19 | 4.3000 | |
Total | 2090.32 | 15.5746 | 3.10 | 4.3000 | |||||||
Conditioned Total | 2090.32 | 15.5746 | 3.10 | 4.3000 | |||||||
Unconditioned Total | 0.00 | 0.0000 | 0.00 | 0.0000 | |||||||
Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
GENERAL | 2090.32 | 2090.32 | 0.00 | 0.00 | 15.5746 | 6.19 | 4.3000 |
Total | 2090.32 | 2090.32 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
End UsesElectricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 29-JUN-16:30 | 06-JAN-09:09 | - | - | - | - | - | - | - | - | - | - | 06-JAN-13:09 |
Heating | 0.00 | 371004.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 43714.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 27522.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 7988.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 690.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 9690.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 97695.45 | 371004.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 371004.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 43714.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 27522.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 7988.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 690.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 9690.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 1025.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 179.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1398.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 316.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 407.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 347.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 29.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 213.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 2893.22 | 1025.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 490.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 86.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 668.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 151.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 166.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 13.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 102.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1384.10 | 490.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 490.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 86.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 668.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 151.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 166.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 13.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 102.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1384.10 | 490.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
AirTerminal:SingleDuct:ConstantVolume:NoReheatDesign Size Maximum Air Flow Rate [m3/s] | |
LGSTORE1 DIRECT AIR | 2.03 |
SMSTORE1 DIRECT AIR | 1.07 |
SMSTORE2 DIRECT AIR | 1.07 |
SMSTORE3 DIRECT AIR | 1.07 |
SMSTORE4 DIRECT AIR | 1.07 |
LGSTORE2 DIRECT AIR | 1.97 |
SMSTORE5 DIRECT AIR | 1.02 |
SMSTORE6 DIRECT AIR | 1.01 |
SMSTORE7 DIRECT AIR | 1.01 |
SMSTORE8 DIRECT AIR | 1.24 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC_1:1 | 2.03 | 2.03 | 2.03 | 2.03 | 2.03 | 2.03 | 1.00 | 1.00 | 2.03 |
PSZ-AC_2:2 | 1.07 | 1.07 | 1.07 | 1.07 | 1.07 | 1.07 | 1.00 | 1.00 | 1.07 |
PSZ-AC_3:3 | 1.07 | 1.07 | 1.07 | 1.07 | 1.07 | 1.07 | 1.00 | 1.00 | 1.07 |
PSZ-AC_4:4 | 1.07 | 1.07 | 1.07 | 1.07 | 1.07 | 1.07 | 1.00 | 1.00 | 1.07 |
PSZ-AC_5:5 | 1.07 | 1.07 | 1.07 | 1.07 | 1.07 | 1.07 | 1.00 | 1.00 | 1.07 |
PSZ-AC_6:6 | 1.97 | 1.97 | 1.97 | 1.97 | 1.97 | 1.97 | 1.00 | 1.00 | 1.97 |
PSZ-AC_7:7 | 1.02 | 1.02 | 1.02 | 1.02 | 1.02 | 1.02 | 1.00 | 0.997380 | 1.02 |
PSZ-AC_8:8 | 1.01 | 1.01 | 1.01 | 1.01 | 1.02 | 1.02 | 1.00 | 0.997008 | 1.02 |
PSZ-AC_9:9 | 1.01 | 1.01 | 1.01 | 1.01 | 1.01 | 1.01 | 1.00 | 1.00 | 1.01 |
PSZ-AC_10:10 | 1.24 | 1.24 | 1.24 | 1.24 | 1.24 | 1.24 | 1.00 | 1.00 | 1.24 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC_1:1_OA_CONTROLLER | 2.03 | 0.411479 |
PSZ-AC_2:2_OA_CONTROLLER | 1.07 | 0.205739 |
PSZ-AC_3:3_OA_CONTROLLER | 1.07 | 0.205739 |
PSZ-AC_4:4_OA_CONTROLLER | 1.07 | 0.205739 |
PSZ-AC_5:5_OA_CONTROLLER | 1.07 | 0.205739 |
PSZ-AC_6:6_OA_CONTROLLER | 1.97 | 0.411479 |
PSZ-AC_7:7_OA_CONTROLLER | 1.02 | 0.205739 |
PSZ-AC_8:8_OA_CONTROLLER | 1.02 | 0.205739 |
PSZ-AC_9:9_OA_CONTROLLER | 1.01 | 0.205739 |
PSZ-AC_10:10_OA_CONTROLLER | 1.24 | 0.205739 |
Design Size Nominal Supply Air Flow Rate [m3/s] | |
PSZ-AC_1:1 OA HEAT RECOVERY | 0.411479 |
PSZ-AC_6:6 OA HEAT RECOVERY | 0.411479 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | 2.03 | 2169.92 |
PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | 1.07 | 1185.94 |
PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.07 | 1184.25 |
PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | 1.07 | 1188.06 |
PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | 1.07 | 1183.34 |
PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | 1.97 | 2109.25 |
PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | 1.02 | 1132.07 |
PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | 1.02 | 1126.24 |
PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | 1.01 | 1122.49 |
PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | 1.24 | 1372.63 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC_1:1_UNITARY_PACKAGE_DX | 2.03 | 2.03 | 2.03 | 1.34 | 41181.84 | 70101.09 | 40.00 | 1.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_DX | 1.07 | 1.07 | 1.07 | 0.706962 | 21514.43 | 36304.10 | 40.00 | 1.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_DX | 1.07 | 1.07 | 1.07 | 0.705955 | 21490.52 | 36270.68 | 40.00 | 1.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_DX | 1.07 | 1.07 | 1.07 | 0.708225 | 21544.55 | 36346.02 | 40.00 | 1.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_DX | 1.07 | 1.07 | 1.07 | 0.705413 | 21477.64 | 36252.68 | 40.00 | 1.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_DX | 1.97 | 1.97 | 1.97 | 1.30 | 40165.33 | 68858.05 | 40.00 | 1.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_DX | 1.02 | 1.02 | 1.02 | 0.674848 | 20751.85 | 35179.30 | 40.00 | 1.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_DX | 1.02 | 1.02 | 1.02 | 0.671374 | 20672.17 | 35056.00 | 40.00 | 1.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_DX | 1.01 | 1.01 | 1.01 | 0.669140 | 20622.29 | 35048.53 | 40.00 | 1.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_DX | 1.24 | 1.24 | 1.24 | 0.818252 | 24839.41 | 39999.27 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | User-Specified Speed 2 Rated Sensible Heat Ratio | User-Specified Speed 1 Rated Sensible Heat Ratio | |
PSZ-AC_1:1 COOLING COIL | 2.03 | 1.01 | 1.35 | 41181.84 | 20590.92 | 0.770690 | 0.770690 |
PSZ-AC_2:2 COOLING COIL | 1.07 | 0.535577 | 0.714100 | 21514.43 | 10757.22 | 0.774010 | 0.774010 |
PSZ-AC_3:3 COOLING COIL | 1.07 | 0.534814 | 0.713087 | 21490.52 | 10745.26 | 0.773910 | 0.773910 |
PSZ-AC_4:4 COOLING COIL | 1.07 | 0.536534 | 0.715380 | 21544.55 | 10772.27 | 0.775120 | 0.775120 |
PSZ-AC_5:5 COOLING COIL | 1.07 | 0.534404 | 0.712540 | 21477.64 | 10738.82 | 0.773860 | 0.773860 |
PSZ-AC_6:6 COOLING COIL | 1.97 | 0.985587 | 1.31 | 40165.33 | 20082.67 | 0.768680 | 0.768680 |
PSZ-AC_7:7 COOLING COIL | 1.02 | 0.511248 | 0.681667 | 20751.85 | 10375.92 | 0.770870 | 0.770870 |
PSZ-AC_8:8 COOLING COIL | 1.02 | 0.508617 | 0.678153 | 20672.17 | 10336.08 | 0.769480 | 0.769480 |
PSZ-AC_9:9 COOLING COIL | 1.01 | 0.506924 | 0.675900 | 20622.29 | 10311.15 | 0.769200 | 0.769200 |
PSZ-AC_10:10 COOLING COIL | 1.24 | 0.619888 | 0.826520 | 24839.41 | 12419.70 | 0.775760 | 0.775760 |
Design Size Nominal Capacity [W] | |
PSZ-AC_1:1 HEATING COIL | 70101.09 |
PSZ-AC_2:2 HEATING COIL | 36304.10 |
PSZ-AC_3:3 HEATING COIL | 36270.68 |
PSZ-AC_4:4 HEATING COIL | 36346.02 |
PSZ-AC_5:5 HEATING COIL | 36252.68 |
PSZ-AC_6:6 HEATING COIL | 68858.05 |
PSZ-AC_7:7 HEATING COIL | 35179.30 |
PSZ-AC_8:8 HEATING COIL | 35056.00 |
PSZ-AC_9:9 HEATING COIL | 35048.53 |
PSZ-AC_10:10 HEATING COIL | 39999.27 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
LGSTORE1_WALL_3 | LGSTORE1_WALL_3_DOOR_1 | LGSTORE1_WALL_3_DOOR_2 | |
LGSTORE1_WALL_1 | LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | |
SMSTORE1_WALL_1 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | |
SMSTORE1_WALL_3 | SMSTORE1_WALL_3_DOOR | |
SMSTORE2_WALL_1 | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | |
SMSTORE2_WALL_3 | SMSTORE2_WALL_3_DOOR | |
SMSTORE3_WALL_1 | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | |
SMSTORE3_WALL_3 | SMSTORE3_WALL_3_DOOR | |
SMSTORE4_WALL_1 | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | |
SMSTORE4_WALL_3 | SMSTORE4_WALL_3_DOOR | |
LGSTORE2_WALL_3 | LGSTORE2_WALL_3_DOOR_1 | LGSTORE2_WALL_3_DOOR_2 | |
LGSTORE2_WALL_1 | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | |
SMSTORE5_WALL_1 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | |
SMSTORE5_WALL_3 | SMSTORE5_WALL_3_DOOR | |
SMSTORE6_WALL_1 | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | |
SMSTORE6_WALL_3 | SMSTORE6_WALL_3_DOOR | |
SMSTORE7_WALL_1 | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | |
SMSTORE7_WALL_3 | SMSTORE7_WALL_3_DOOR | |
SMSTORE8_WALL_1 | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR | |
SMSTORE8_WALL_3 | SMSTORE8_WALL_3_DOOR | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
VersionVersion ID | |
1 | 22.1 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 5.40 | -2.00 | -14.60 | -16.90 | -11.50 | -6.20 | 4.00 | 13.40 | 18.00 | 19.70 | 17.90 | 12.30 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | International Falls Intl Ap MN USA TMY3 WMO#=727470 | 48.57 | -93.40 | -6.00 | 359.00 | 97086 | 1.1539 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 3.29 | 36.60 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStripmall | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 10 | 118 | 48 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | LGSTORE1 | 0.0 | 0.00 | 0.00 | 0.00 | 7.62 | 11.43 | 2.59 | 1 | 1 | 1 | 0.00 | 15.24 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 1805.20 | TARP | TARP | 348.39 | 276.30 | 247.74 | 20.77 | 6 | 8 | 0 | Yes |
2 | SMSTORE1 | 0.0 | 0.00 | 0.00 | 0.00 | 19.05 | 11.43 | 2.59 | 1 | 1 | 1 | 15.24 | 22.86 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.66 | 10.38 | 6 | 4 | 0 | Yes |
3 | SMSTORE2 | 0.0 | 0.00 | 0.00 | 0.00 | 26.67 | 11.43 | 2.59 | 1 | 1 | 1 | 22.86 | 30.48 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.36 | 6 | 4 | 0 | Yes |
4 | SMSTORE3 | 0.0 | 0.00 | 0.00 | 0.00 | 34.29 | 11.43 | 2.59 | 1 | 1 | 1 | 30.48 | 38.10 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.36 | 6 | 4 | 0 | Yes |
5 | SMSTORE4 | 0.0 | 0.00 | 0.00 | 0.00 | 41.91 | 11.43 | 2.59 | 1 | 1 | 1 | 38.10 | 45.72 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.36 | 6 | 4 | 0 | Yes |
6 | LGSTORE2 | 0.0 | 0.00 | 0.00 | 0.00 | 53.34 | 11.43 | 2.59 | 1 | 1 | 1 | 45.72 | 60.96 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 1805.20 | TARP | TARP | 348.39 | 157.89 | 129.41 | 20.72 | 6 | 8 | 0 | Yes |
7 | SMSTORE5 | 0.0 | 0.00 | 0.00 | 0.00 | 64.77 | 11.43 | 2.59 | 1 | 1 | 1 | 60.96 | 68.58 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.36 | 6 | 4 | 0 | Yes |
8 | SMSTORE6 | 0.0 | 0.00 | 0.00 | 0.00 | 72.39 | 11.43 | 2.59 | 1 | 1 | 1 | 68.58 | 76.20 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.36 | 6 | 4 | 0 | Yes |
9 | SMSTORE7 | 0.0 | 0.00 | 0.00 | 0.00 | 80.01 | 11.43 | 2.59 | 1 | 1 | 1 | 76.20 | 83.82 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.36 | 6 | 4 | 0 | Yes |
10 | SMSTORE8 | 0.0 | 0.00 | 0.00 | 0.00 | 87.63 | 11.43 | 2.59 | 1 | 1 | 1 | 83.82 | 91.44 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 197.36 | 183.12 | 10.36 | 6 | 4 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | LGSTORE1 | 348.39 | 56.3 | 6.193 | 0.161 | 17.877 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.177 | No |
2 | SMSTORE1 | 174.19 | 28.1 | 6.194 | 0.161 | 19.338 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 23.638 | No |
3 | SMSTORE2 | 174.19 | 28.1 | 6.194 | 0.161 | 17.374 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 21.674 | No |
4 | SMSTORE3 | 174.19 | 28.1 | 6.194 | 0.161 | 17.374 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 21.674 | No |
5 | SMSTORE4 | 174.19 | 28.1 | 6.194 | 0.161 | 17.374 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 21.674 | No |
6 | LGSTORE2 | 348.39 | 56.3 | 6.193 | 0.161 | 13.168 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 17.468 | No |
7 | SMSTORE5 | 174.19 | 28.1 | 6.194 | 0.161 | 13.336 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 17.636 | No |
8 | SMSTORE6 | 174.19 | 28.1 | 6.194 | 0.161 | 13.336 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 17.636 | No |
9 | SMSTORE7 | 174.19 | 28.1 | 6.194 | 0.161 | 13.336 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 17.636 | No |
10 | SMSTORE8 | 174.19 | 28.1 | 6.194 | 0.161 | 13.336 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 17.636 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | Cooling Effect Calculation | Ankle Draft Calculation | |
1 | LGSTORE1 | TYPE1_OCC_SCH | LGSTORE1 | 348.39 | 56.3 | 56.3 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 56 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
2 | SMSTORE1 | TYPE1_OCC_SCH | SMSTORE1 | 174.19 | 28.1 | 28.1 | 0.161 | 6.194 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 28 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
3 | SMSTORE2 | TYPE2_OCC_SCH | SMSTORE2 | 174.19 | 28.1 | 28.1 | 0.161 | 6.194 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 28 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
4 | SMSTORE3 | TYPE2_OCC_SCH | SMSTORE3 | 174.19 | 28.1 | 28.1 | 0.161 | 6.194 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 28 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
5 | SMSTORE4 | TYPE2_OCC_SCH | SMSTORE4 | 174.19 | 28.1 | 28.1 | 0.161 | 6.194 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 28 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
6 | LGSTORE2 | TYPE3_OCC_SCH | LGSTORE2 | 348.39 | 56.3 | 56.3 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 56 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
7 | SMSTORE5 | TYPE3_OCC_SCH | SMSTORE5 | 174.19 | 28.1 | 28.1 | 0.161 | 6.194 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 28 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
8 | SMSTORE6 | TYPE3_OCC_SCH | SMSTORE6 | 174.19 | 28.1 | 28.1 | 0.161 | 6.194 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 28 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
9 | SMSTORE7 | TYPE3_OCC_SCH | SMSTORE7 | 174.19 | 28.1 | 28.1 | 0.161 | 6.194 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 28 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
10 | SMSTORE8 | TYPE3_OCC_SCH | SMSTORE8 | 174.19 | 28.1 | 28.1 | 0.161 | 6.194 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 28 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | LGSTORE1_LIGHTS | LTG_SCH_BASE_LPD1 | LGSTORE1 | 348.39 | 56.3 | 4596.695 | 13.194 | 81.718 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 4596.695 |
2 | LGSTORE1_LIGHTS_ALLOWANCE | LTG_SCH_DISPLAY_LPD_TYPE3_LGSTORE | LGSTORE1 | 348.39 | 56.3 | 1631.408 | 4.683 | 29.003 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1631.408 |
3 | SMSTORE1_LIGHTS | LTG_SCH_BASE_SMALL_LPD1 | SMSTORE1 | 174.19 | 28.1 | 2327.780 | 13.363 | 82.767 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2327.780 |
4 | SMSTORE1_LIGHTS_ALLOWANCE | LTG_SCH_DISPLAY_LPD_TYPE3_SMSTORE | SMSTORE1 | 174.19 | 28.1 | 1040.795 | 5.975 | 37.007 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1040.795 |
5 | SMSTORE2_LIGHTS | LTG_SCH_BASE_SMALL_LPD2_TYPE2 | SMSTORE2 | 174.19 | 28.1 | 2323.122 | 13.336 | 82.601 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2323.122 |
6 | SMSTORE2_LIGHTS_ALLOWANCE | LTG_SCH_DISPLAY_LPD_TYPE2_SMSTORE | SMSTORE2 | 174.19 | 28.1 | 703.295 | 4.037 | 25.007 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 703.295 |
7 | SMSTORE3_LIGHTS | LTG_SCH_BASE_SMALL_LPD2_TYPE2 | SMSTORE3 | 174.19 | 28.1 | 2323.122 | 13.336 | 82.601 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2323.122 |
8 | SMSTORE3_LIGHTS_ALLOWANCE | LTG_SCH_DISPLAY_LPD_TYPE2_SMSTORE | SMSTORE3 | 174.19 | 28.1 | 703.295 | 4.037 | 25.007 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 703.295 |
9 | SMSTORE4_LIGHTS | LTG_SCH_BASE_SMALL_LPD2_TYPE2 | SMSTORE4 | 174.19 | 28.1 | 2323.122 | 13.336 | 82.601 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2323.122 |
10 | SMSTORE4_LIGHTS_ALLOWANCE | LTG_SCH_DISPLAY_LPD_TYPE2_SMSTORE | SMSTORE4 | 174.19 | 28.1 | 703.295 | 4.037 | 25.007 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 703.295 |
11 | LGSTORE2_LIGHTS | LTG_SCH_BASE_LPD2 | LGSTORE2 | 348.39 | 56.3 | 4587.379 | 13.168 | 81.553 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 4587.379 |
12 | LGSTORE2_LIGHTS_ALLOWANCE | LTG_SCH_DISPLAY_LPD_TYPE1_LGSTORE | LGSTORE2 | 348.39 | 56.3 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
13 | SMSTORE5_LIGHTS | LTG_SCH_BASE_SMALL_LPD2_TYPE3 | SMSTORE5 | 174.19 | 28.1 | 2323.122 | 13.336 | 82.601 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2323.122 |
14 | SMSTORE5_LIGHTS_ALLOWANCE | LTG_SCH_DISPLAY_LPD_TYPE1_SMSTORE | SMSTORE5 | 174.19 | 28.1 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
15 | SMSTORE6_LIGHTS | LTG_SCH_BASE_SMALL_LPD2_TYPE3 | SMSTORE6 | 174.19 | 28.1 | 2323.122 | 13.336 | 82.601 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2323.122 |
16 | SMSTORE6_LIGHTS_ALLOWANCE | LTG_SCH_DISPLAY_LPD_TYPE1_SMSTORE | SMSTORE6 | 174.19 | 28.1 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
17 | SMSTORE7_LIGHTS | LTG_SCH_BASE_SMALL_LPD2_TYPE3 | SMSTORE7 | 174.19 | 28.1 | 2323.122 | 13.336 | 82.601 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2323.122 |
18 | SMSTORE7_LIGHTS_ALLOWANCE | LTG_SCH_DISPLAY_LPD_TYPE1_SMSTORE | SMSTORE7 | 174.19 | 28.1 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
19 | SMSTORE8_LIGHTS | LTG_SCH_BASE_SMALL_LPD2_TYPE3 | SMSTORE8 | 174.19 | 28.1 | 2323.122 | 13.336 | 82.601 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2323.122 |
20 | SMSTORE8_LIGHTS_ALLOWANCE | LTG_SCH_DISPLAY_LPD_TYPE1_SMSTORE | SMSTORE8 | 174.19 | 28.1 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | LGSTORE1_MISCPLUG_EQUIP | TYPE1_EQUIP_SCH | LGSTORE1 | 348.39 | 56.3 | 1498.062 | 4.300 | 26.632 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1498.062 |
2 | SMSTORE1_MISCPLUG_EQUIP | TYPE1_EQUIP_SCH | SMSTORE1 | 174.19 | 28.1 | 749.031 | 4.300 | 26.633 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
3 | SMSTORE2_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE2 | 174.19 | 28.1 | 749.031 | 4.300 | 26.633 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
4 | SMSTORE3_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE3 | 174.19 | 28.1 | 749.031 | 4.300 | 26.633 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
5 | SMSTORE4_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE4 | 174.19 | 28.1 | 749.031 | 4.300 | 26.633 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
6 | LGSTORE2_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | LGSTORE2 | 348.39 | 56.3 | 1498.062 | 4.300 | 26.632 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1498.062 |
7 | SMSTORE5_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE5 | 174.19 | 28.1 | 749.031 | 4.300 | 26.633 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
8 | SMSTORE6_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE6 | 174.19 | 28.1 | 749.031 | 4.300 | 26.633 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
9 | SMSTORE7_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE7 | 174.19 | 28.1 | 749.031 | 4.300 | 26.633 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
10 | SMSTORE8_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE8 | 174.19 | 28.1 | 749.031 | 4.300 | 26.633 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | INTERIORFURNISHINGS | 2 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
3 | INT_WALL | 7 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | NONRES_ROOF | 17 | 3 | 3 | 0.167 | 0.1625 | 0.900 | 0.900 | 0.770 | 0.700 | Rough |
5 | NONRES_EXT_WALL_GRD | 20 | 4 | 7 | 0.167 | 0.6641 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
6 | LGSTORE1_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.1078 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
7 | SMSTORE1_FLOOR_FFACTOR | 37 | 2 | 7 | 0.167 | 0.6115E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | SMSTORE2_FLOOR_FFACTOR | 38 | 2 | 7 | 0.167 | 0.6115E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | SMSTORE3_FLOOR_FFACTOR | 39 | 2 | 7 | 0.167 | 0.6115E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | SMSTORE4_FLOOR_FFACTOR | 40 | 2 | 7 | 0.167 | 0.6115E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | LGSTORE2_FLOOR_FFACTOR | 41 | 2 | 7 | 0.167 | 0.6115E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
12 | SMSTORE5_FLOOR_FFACTOR | 42 | 2 | 7 | 0.167 | 0.6115E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | SMSTORE6_FLOOR_FFACTOR | 43 | 2 | 7 | 0.167 | 0.6115E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | SMSTORE7_FLOOR_FFACTOR | 44 | 2 | 7 | 0.167 | 0.6115E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | SMSTORE8_FLOOR_FFACTOR | 45 | 2 | 7 | 0.167 | 0.1551 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
2 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
3 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
6 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 6.093 |
7 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
8 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
9 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 1.272 |
11 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 9.201 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 16.28 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 16.28 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 16.28 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 16.28 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
22 | ~FC_Insulation_6 | 0.0000 | 0.000 | 0.000 | 0.000 | 16.28 |
23 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
24 | ~FC_Insulation_7 | 0.0000 | 0.000 | 0.000 | 0.000 | 16.28 |
25 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
26 | ~FC_Insulation_8 | 0.0000 | 0.000 | 0.000 | 0.000 | 16.28 |
27 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
28 | ~FC_Insulation_9 | 0.0000 | 0.000 | 0.000 | 0.000 | 16.28 |
29 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
30 | ~FC_Insulation_10 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.371 |
31 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 2.1009573 | 2.1009573 | 2.1009573 | |
3 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
4 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
5 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
6 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
7 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
8 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
9 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
10 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
11 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
12 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
13 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
14 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
15 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
16 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
17 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
18 | 3 | -0.63083111E-06 | 0.74112372E-09 | -0.38647046E-05 | 0.15329585E-16 |
19 | 2 | 0.78415922 | 0.99752939E-03 | 1.0633801 | -0.74093433E-06 |
20 | 1 | -22.010056 | 0.66447931E-01 | -6.3131541 | 0.20386814 |
21 | 0 | 21.355302 | 0.61958938E-01 | 5.3791822 | |
22 | 7 | -0.32972738E-12 | 0.11763143E-14 | -0.10490290E-12 | 0.10060316E-15 |
23 | 6 | 0.30001920E-07 | 0.18927851E-09 | 0.68616814E-08 | -0.14235861E-12 |
24 | 5 | -0.19683904E-03 | 0.16062604E-05 | -0.10115234E-03 | 0.67789156E-08 |
25 | 4 | 0.29998857 | 0.77587294E-03 | 0.10250533 | -0.34681058E-04 |
26 | 3 | -7.4215481 | 0.23875067E-01 | -2.3849775 | 0.29769922E-01 |
27 | 2 | 41.382972 | 0.84366340E-01 | 15.453844 | -0.33904133 |
28 | 1 | -80.937908 | 0.37867119E-01 | -29.310851 | 1.0869756 |
29 | 0 | 46.824336 | 0.75775345E-03 | 16.287225 | |
30 | 7 | -0.39532248E-08 | -0.44064807E-14 | 0.10109291E-14 | -0.41601153E-16 |
31 | 6 | 0.32173895E-05 | 0.20629171E-08 | 0.31970178E-02 | -0.26819265E-04 |
32 | 5 | -0.22044530E-03 | 0.12181552E-05 | -0.22413079 | 0.19597358E-02 |
33 | 4 | 0.49988388E-02 | 0.55368910E-04 | 4.8363104 | -0.45330008E-01 |
34 | 3 | -0.43669331E-01 | 0.43971237E-03 | -38.059625 | 0.39907609 |
35 | 2 | 0.15474085 | 0.73065327E-03 | 116.55831 | -1.4189339 |
36 | 1 | -0.22313860 | 0.22222429E-03 | -143.95108 | 2.0497593 |
37 | 0 | 0.10874004 | 0.53957455E-05 | 60.838472 | |
38 | 7 | -0.70007713E-08 | -0.80410658E-14 | -0.90308164E-15 | 0.82137675E-17 |
39 | 6 | 0.21712725E-05 | 0.11838265E-08 | 0.32006334E-02 | -0.26849596E-04 |
40 | 5 | -0.13301509E-03 | 0.69458749E-06 | -0.22433613 | 0.19615483E-02 |
41 | 4 | 0.29052452E-02 | 0.31467785E-04 | 4.8397276 | -0.45362860E-01 |
42 | 3 | -0.25016136E-01 | 0.24921377E-03 | -38.078914 | 0.39928933 |
43 | 2 | 0.88121217E-01 | 0.41303221E-03 | 116.59583 | -1.4194359 |
44 | 1 | -0.12672960 | 0.12519520E-03 | -143.97316 | 2.0501223 |
45 | 0 | 0.61672764E-01 | 0.30323733E-05 | 60.838472 | |
46 | 7 | -0.70007713E-08 | -0.80410659E-14 | -0.90308145E-15 | 0.82137644E-17 |
47 | 6 | 0.21712725E-05 | 0.11838265E-08 | 0.32006334E-02 | -0.26849596E-04 |
48 | 5 | -0.13301509E-03 | 0.69458749E-06 | -0.22433613 | 0.19615483E-02 |
49 | 4 | 0.29052452E-02 | 0.31467785E-04 | 4.8397276 | -0.45362860E-01 |
50 | 3 | -0.25016136E-01 | 0.24921377E-03 | -38.078914 | 0.39928933 |
51 | 2 | 0.88121217E-01 | 0.41303221E-03 | 116.59583 | -1.4194359 |
52 | 1 | -0.12672960 | 0.12519520E-03 | -143.97316 | 2.0501223 |
53 | 0 | 0.61672764E-01 | 0.30323733E-05 | 60.838472 | |
54 | 7 | -0.70007713E-08 | -0.80410658E-14 | -0.90308157E-15 | 0.82137664E-17 |
55 | 6 | 0.21712725E-05 | 0.11838265E-08 | 0.32006334E-02 | -0.26849596E-04 |
56 | 5 | -0.13301509E-03 | 0.69458749E-06 | -0.22433613 | 0.19615483E-02 |
57 | 4 | 0.29052452E-02 | 0.31467785E-04 | 4.8397276 | -0.45362860E-01 |
58 | 3 | -0.25016136E-01 | 0.24921377E-03 | -38.078914 | 0.39928933 |
59 | 2 | 0.88121217E-01 | 0.41303221E-03 | 116.59583 | -1.4194359 |
60 | 1 | -0.12672960 | 0.12519520E-03 | -143.97316 | 2.0501223 |
61 | 0 | 0.61672764E-01 | 0.30323733E-05 | 60.838472 | |
62 | 7 | -0.70007713E-08 | -0.80410657E-14 | -0.90308142E-15 | 0.82137640E-17 |
63 | 6 | 0.21712725E-05 | 0.11838265E-08 | 0.32006334E-02 | -0.26849596E-04 |
64 | 5 | -0.13301509E-03 | 0.69458749E-06 | -0.22433613 | 0.19615483E-02 |
65 | 4 | 0.29052452E-02 | 0.31467785E-04 | 4.8397276 | -0.45362860E-01 |
66 | 3 | -0.25016136E-01 | 0.24921377E-03 | -38.078914 | 0.39928933 |
67 | 2 | 0.88121217E-01 | 0.41303221E-03 | 116.59583 | -1.4194359 |
68 | 1 | -0.12672960 | 0.12519520E-03 | -143.97316 | 2.0501223 |
69 | 0 | 0.61672764E-01 | 0.30323733E-05 | 60.838472 | |
70 | 7 | -0.70007713E-08 | -0.80410659E-14 | -0.90308145E-15 | 0.82137644E-17 |
71 | 6 | 0.21712725E-05 | 0.11838265E-08 | 0.32006334E-02 | -0.26849596E-04 |
72 | 5 | -0.13301509E-03 | 0.69458749E-06 | -0.22433613 | 0.19615483E-02 |
73 | 4 | 0.29052452E-02 | 0.31467785E-04 | 4.8397276 | -0.45362860E-01 |
74 | 3 | -0.25016136E-01 | 0.24921377E-03 | -38.078914 | 0.39928933 |
75 | 2 | 0.88121217E-01 | 0.41303221E-03 | 116.59583 | -1.4194359 |
76 | 1 | -0.12672960 | 0.12519520E-03 | -143.97316 | 2.0501223 |
77 | 0 | 0.61672764E-01 | 0.30323733E-05 | 60.838472 | |
78 | 7 | -0.70007713E-08 | -0.80410659E-14 | -0.90308158E-15 | 0.82137665E-17 |
79 | 6 | 0.21712725E-05 | 0.11838265E-08 | 0.32006334E-02 | -0.26849596E-04 |
80 | 5 | -0.13301509E-03 | 0.69458749E-06 | -0.22433613 | 0.19615483E-02 |
81 | 4 | 0.29052452E-02 | 0.31467785E-04 | 4.8397276 | -0.45362860E-01 |
82 | 3 | -0.25016136E-01 | 0.24921377E-03 | -38.078914 | 0.39928933 |
83 | 2 | 0.88121217E-01 | 0.41303221E-03 | 116.59583 | -1.4194359 |
84 | 1 | -0.12672960 | 0.12519520E-03 | -143.97316 | 2.0501223 |
85 | 0 | 0.61672764E-01 | 0.30323733E-05 | 60.838472 | |
86 | 7 | -0.70007713E-08 | -0.80410658E-14 | -0.90308164E-15 | 0.82137675E-17 |
87 | 6 | 0.21712725E-05 | 0.11838265E-08 | 0.32006334E-02 | -0.26849596E-04 |
88 | 5 | -0.13301509E-03 | 0.69458749E-06 | -0.22433613 | 0.19615483E-02 |
89 | 4 | 0.29052452E-02 | 0.31467785E-04 | 4.8397276 | -0.45362860E-01 |
90 | 3 | -0.25016136E-01 | 0.24921377E-03 | -38.078914 | 0.39928933 |
91 | 2 | 0.88121217E-01 | 0.41303221E-03 | 116.59583 | -1.4194359 |
92 | 1 | -0.12672960 | 0.12519520E-03 | -143.97316 | 2.0501223 |
93 | 0 | 0.61672764E-01 | 0.30323733E-05 | 60.838472 | |
94 | 7 | -0.70007713E-08 | -0.80410659E-14 | -0.90308145E-15 | 0.82137644E-17 |
95 | 6 | 0.21712725E-05 | 0.11838265E-08 | 0.32006334E-02 | -0.26849596E-04 |
96 | 5 | -0.13301509E-03 | 0.69458749E-06 | -0.22433613 | 0.19615483E-02 |
97 | 4 | 0.29052452E-02 | 0.31467785E-04 | 4.8397276 | -0.45362860E-01 |
98 | 3 | -0.25016136E-01 | 0.24921377E-03 | -38.078914 | 0.39928933 |
99 | 2 | 0.88121217E-01 | 0.41303221E-03 | 116.59583 | -1.4194359 |
100 | 1 | -0.12672960 | 0.12519520E-03 | -143.97316 | 2.0501223 |
101 | 0 | 0.61672764E-01 | 0.30323733E-05 | 60.838472 | |
102 | 7 | -0.27342154E-08 | -0.14755226E-14 | 0.78892317E-14 | -0.11406260E-15 |
103 | 6 | 0.44275096E-05 | 0.29655051E-08 | 0.31933384E-02 | -0.26788399E-04 |
104 | 5 | -0.31313574E-03 | 0.17544743E-05 | -0.22392171 | 0.19578903E-02 |
105 | 4 | 0.71689416E-02 | 0.79816958E-04 | 4.8328290 | -0.45296542E-01 |
106 | 3 | -0.62848542E-01 | 0.63438109E-03 | -38.039963 | 0.39885876 |
107 | 2 | 0.22301735 | 0.10548637E-02 | 116.52005 | -1.4184221 |
108 | 1 | -0.32179990 | 0.32117902E-03 | -143.92856 | 2.0493892 |
109 | 0 | 0.15687064 | 0.77839935E-05 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | Conductance (Before Adjusted) {W/m2-K} | Convection Coefficient Adjustment Ratio | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 35 | 1 | VerySmooth | 1.657 | 1.657 | 1.000 | 0.451 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 4.25070E-002 | 0.36619 | 0.44094 | 0.44094 | 0.45000 | 0.13324 | 0.16828 | 0.00000 | 0.84000 | 0.84000 | 9.90222E-002 | 1.00000 | No |
Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | PolygonClipping | Periodic | 30 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK1 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
2 | WaterHeater:Mixed | GAS TANK2 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
3 | WaterHeater:Mixed | GAS TANK3 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
4 | WaterHeater:Mixed | GAS TANK4 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
5 | WaterHeater:Mixed | GAS TANK5 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
6 | WaterHeater:Mixed | GAS TANK6 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
7 | WaterHeater:Mixed | GAS TANK7 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | LGSTORE1_WALL_2 | 0 | 118.41 | 56.08 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.52E-002 | 4 | No | No |
2 | LGSTORE1_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.52E-002 | 4 | No | No |
3 | LGSTORE1_WALL_3_DOOR_1 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.52E-002 | 0 | No | No |
4 | LGSTORE1_WALL_3_DOOR_2 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.52E-002 | 0 | No | No |
5 | LGSTORE1_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.52E-002 | 0 | No | No |
6 | LGSTORE1_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.52E-002 | 4 | No | No |
7 | LGSTORE1_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.52E-002 | 2 | No | No |
8 | LGSTORE1_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.52E-002 | 2 | No | No |
9 | LGSTORE1_WALL_1_WINDOW_3 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.52E-002 | 2 | No | No |
10 | LGSTORE1_WALL_1_WINDOW_4 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.52E-002 | 2 | No | No |
11 | LGSTORE1_WALL_1_DOOR_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.52E-002 | 1 | No | No |
12 | LGSTORE1_WALL_1_DOOR_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.52E-002 | 1 | No | No |
13 | LGSTORE1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.52E-002 | 0 | No | No |
14 | LGSTORE1_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.52E-002 | 0 | No | No |
15 | LGSTORE1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.52E-002 | 0 | No | No |
16 | SMSTORE1_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
17 | SMSTORE1_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 2 | No | No |
18 | SMSTORE1_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 2 | No | No |
19 | SMSTORE1_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
20 | SMSTORE1_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
21 | SMSTORE1_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
22 | SMSTORE1_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
23 | SMSTORE1_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
24 | SMSTORE1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
25 | SMSTORE1_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
26 | SMSTORE1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
27 | SMSTORE2_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
28 | SMSTORE2_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 2 | No | No |
29 | SMSTORE2_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 2 | No | No |
30 | SMSTORE2_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
31 | SMSTORE2_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
32 | SMSTORE2_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
33 | SMSTORE2_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
34 | SMSTORE2_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
35 | SMSTORE2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
36 | SMSTORE2_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
37 | SMSTORE2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
38 | SMSTORE3_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
39 | SMSTORE3_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 2 | No | No |
40 | SMSTORE3_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 2 | No | No |
41 | SMSTORE3_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
42 | SMSTORE3_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
43 | SMSTORE3_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
44 | SMSTORE3_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
45 | SMSTORE3_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
46 | SMSTORE3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
47 | SMSTORE3_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
48 | SMSTORE3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
49 | SMSTORE4_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
50 | SMSTORE4_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 2 | No | No |
51 | SMSTORE4_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 2 | No | No |
52 | SMSTORE4_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
53 | SMSTORE4_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
54 | SMSTORE4_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 3 | No | No |
55 | SMSTORE4_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
56 | SMSTORE4_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
57 | SMSTORE4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
58 | SMSTORE4_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
59 | SMSTORE4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
60 | LGSTORE2_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
61 | LGSTORE2_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 4 | No | No |
62 | LGSTORE2_WALL_3_DOOR_1 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
63 | LGSTORE2_WALL_3_DOOR_2 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
64 | LGSTORE2_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
65 | LGSTORE2_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 4 | No | No |
66 | LGSTORE2_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 2 | No | No |
67 | LGSTORE2_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 2 | No | No |
68 | LGSTORE2_WALL_1_WINDOW_3 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 2 | No | No |
69 | LGSTORE2_WALL_1_WINDOW_4 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 2 | No | No |
70 | LGSTORE2_WALL_1_DOOR_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
71 | LGSTORE2_WALL_1_DOOR_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
72 | LGSTORE2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
73 | LGSTORE2_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
74 | LGSTORE2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
75 | SMSTORE5_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
76 | SMSTORE5_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 2 | No | No |
77 | SMSTORE5_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 2 | No | No |
78 | SMSTORE5_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
79 | SMSTORE5_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
80 | SMSTORE5_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
81 | SMSTORE5_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
82 | SMSTORE5_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
83 | SMSTORE5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
84 | SMSTORE5_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
85 | SMSTORE5_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
86 | SMSTORE6_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
87 | SMSTORE6_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 2 | No | No |
88 | SMSTORE6_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 2 | No | No |
89 | SMSTORE6_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
90 | SMSTORE6_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
91 | SMSTORE6_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
92 | SMSTORE6_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
93 | SMSTORE6_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
94 | SMSTORE6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
95 | SMSTORE6_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
96 | SMSTORE6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
97 | SMSTORE7_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
98 | SMSTORE7_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 2 | No | No |
99 | SMSTORE7_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 2 | No | No |
100 | SMSTORE7_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
101 | SMSTORE7_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
102 | SMSTORE7_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 3 | No | No |
103 | SMSTORE7_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
104 | SMSTORE7_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
105 | SMSTORE7_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
106 | SMSTORE7_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
107 | SMSTORE7_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
108 | SMSTORE8_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 4 | No | No |
109 | SMSTORE8_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 2 | No | No |
110 | SMSTORE8_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 2 | No | No |
111 | SMSTORE8_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
112 | SMSTORE8_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
113 | SMSTORE8_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 3 | No | No |
114 | SMSTORE8_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
115 | SMSTORE8_WALL_4 | 0 | 118.41 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 3 | No | No |
116 | SMSTORE8_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
117 | SMSTORE8_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
118 | SMSTORE8_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | LGSTORE1_INFILTRATION | TYPE1_INFIL_SCH | LGSTORE1 | 348.39 | 56.3 | 0.157 | 4.517E-004 | 2.488E-004 | 0.314 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | LGSTORE1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | LGSTORE1 | 348.39 | 56.3 | 0.241 | 6.922E-004 | 3.813E-004 | 0.481 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | SMSTORE1_INFILTRATION | TYPE1_INFIL_SCH | SMSTORE1 | 174.19 | 28.1 | 4.496E-002 | 2.581E-004 | 1.749E-004 | 0.179 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | SMSTORE1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE1 | 174.19 | 28.1 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
5 | SMSTORE2_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE2 | 174.19 | 28.1 | 4.496E-002 | 2.581E-004 | 1.749E-004 | 0.179 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | SMSTORE2_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE2 | 174.19 | 28.1 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
7 | SMSTORE3_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE3 | 174.19 | 28.1 | 4.496E-002 | 2.581E-004 | 1.749E-004 | 0.179 | 0.000 | 0.000 | 0.224 | 0.000 |
8 | SMSTORE3_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE3 | 174.19 | 28.1 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | SMSTORE4_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE4 | 174.19 | 28.1 | 4.496E-002 | 2.581E-004 | 1.749E-004 | 0.179 | 0.000 | 0.000 | 0.224 | 0.000 |
10 | SMSTORE4_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE4 | 174.19 | 28.1 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
11 | LGSTORE2_INFILTRATION | TYPE3_INFIL_SCH | LGSTORE2 | 348.39 | 56.3 | 8.993E-002 | 2.581E-004 | 1.749E-004 | 0.179 | 0.000 | 0.000 | 0.224 | 0.000 |
12 | LGSTORE2_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | LGSTORE2 | 348.39 | 56.3 | 0.241 | 6.922E-004 | 4.692E-004 | 0.481 | 1.000 | 0.000 | 0.000 | 0.000 |
13 | SMSTORE5_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE5 | 174.19 | 28.1 | 4.496E-002 | 2.581E-004 | 1.749E-004 | 0.179 | 0.000 | 0.000 | 0.224 | 0.000 |
14 | SMSTORE5_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE5 | 174.19 | 28.1 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
15 | SMSTORE6_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE6 | 174.19 | 28.1 | 4.496E-002 | 2.581E-004 | 1.749E-004 | 0.179 | 0.000 | 0.000 | 0.224 | 0.000 |
16 | SMSTORE6_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE6 | 174.19 | 28.1 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
17 | SMSTORE7_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE7 | 174.19 | 28.1 | 4.496E-002 | 2.581E-004 | 1.749E-004 | 0.179 | 0.000 | 0.000 | 0.224 | 0.000 |
18 | SMSTORE7_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE7 | 174.19 | 28.1 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
19 | SMSTORE8_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE8 | 174.19 | 28.1 | 0.112 | 6.453E-004 | 2.994E-004 | 0.448 | 0.000 | 0.000 | 0.224 | 0.000 |
20 | SMSTORE8_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE8 | 174.19 | 28.1 | 0.135 | 7.722E-004 | 3.583E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | LGSTORE1 | Mixing/Well-Stirred |
2 | SMSTORE1 | Mixing/Well-Stirred |
3 | SMSTORE2 | Mixing/Well-Stirred |
4 | SMSTORE3 | Mixing/Well-Stirred |
5 | SMSTORE4 | Mixing/Well-Stirred |
6 | LGSTORE2 | Mixing/Well-Stirred |
7 | SMSTORE5 | Mixing/Well-Stirred |
8 | SMSTORE6 | Mixing/Well-Stirred |
9 | SMSTORE7 | Mixing/Well-Stirred |
10 | SMSTORE8 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone LGSTORE1 | 1.2000 |
3 | Zone SMSTORE1 | 1.2000 |
4 | Zone SMSTORE2 | 1.2000 |
5 | Zone SMSTORE3 | 1.2000 |
6 | Zone SMSTORE4 | 1.2000 |
7 | Zone LGSTORE2 | 1.2000 |
8 | Zone SMSTORE5 | 1.2000 |
9 | Zone SMSTORE6 | 1.2000 |
10 | Zone SMSTORE7 | 1.2000 |
11 | Zone SMSTORE8 | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone LGSTORE1 | 1.2000 |
3 | Zone SMSTORE1 | 1.2000 |
4 | Zone SMSTORE2 | 1.2000 |
5 | Zone SMSTORE3 | 1.2000 |
6 | Zone SMSTORE4 | 1.2000 |
7 | Zone LGSTORE2 | 1.2000 |
8 | Zone SMSTORE5 | 1.2000 |
9 | Zone SMSTORE6 | 1.2000 |
10 | Zone SMSTORE7 | 1.2000 |
11 | Zone SMSTORE8 | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | LGSTORE1 | Cooling | 22063.62379 | 26476.34855 | 1.68990 | 2.02788 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 30.10000 | 1.27259E-002 | 348.38640 | 56.25053 | 0.41148 | 0.00000 |
2 | LGSTORE1 | Heating | 37518.61487 | 45022.33785 | 1.68750 | 2.02500 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -32.70000 | 1.83376E-004 | 348.38640 | 56.25053 | 0.41148 | 0.00000 |
3 | SMSTORE1 | Cooling | 11654.46265 | 13985.35517 | 0.89263 | 1.07115 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 30.10000 | 1.27259E-002 | 174.19320 | 28.12446 | 0.20574 | 0.00000 |
4 | SMSTORE1 | Heating | 17872.06977 | 21446.48373 | 0.80385 | 0.96461 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -32.70000 | 1.83376E-004 | 174.19320 | 28.12446 | 0.20574 | 0.00000 |
5 | SMSTORE2 | Cooling | 11637.87061 | 13965.44473 | 0.89136 | 1.06963 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 30.10000 | 1.27259E-002 | 174.19320 | 28.12446 | 0.20574 | 0.00000 |
6 | SMSTORE2 | Heating | 17996.29083 | 21595.54899 | 0.80943 | 0.97132 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -32.70000 | 1.83376E-004 | 174.19320 | 28.12446 | 0.20574 | 0.00000 |
7 | SMSTORE3 | Cooling | 11675.28911 | 14010.34693 | 0.89422 | 1.07307 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 30.10000 | 1.27259E-002 | 174.19320 | 28.12446 | 0.20574 | 0.00000 |
8 | SMSTORE3 | Heating | 18053.55745 | 21664.26894 | 0.81201 | 0.97441 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -32.70000 | 1.83376E-004 | 174.19320 | 28.12446 | 0.20574 | 0.00000 |
9 | SMSTORE4 | Cooling | 11628.94238 | 13954.73086 | 0.89067 | 1.06881 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 30.10000 | 1.27259E-002 | 174.19320 | 28.12446 | 0.20574 | 0.00000 |
10 | SMSTORE4 | Heating | 18189.54461 | 21827.45354 | 0.81813 | 0.98175 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -32.70000 | 1.83376E-004 | 174.19320 | 28.12446 | 0.20574 | 0.00000 |
11 | LGSTORE2 | Cooling | 21447.02163 | 25736.42595 | 1.64264 | 1.97117 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 29.99667 | 1.27257E-002 | 348.38640 | 56.25053 | 0.41148 | 0.00000 |
12 | LGSTORE2 | Heating | 34475.86986 | 41371.04383 | 1.55068 | 1.86081 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -32.70000 | 1.83376E-004 | 348.38640 | 56.25053 | 0.41148 | 0.00000 |
13 | SMSTORE5 | Cooling | 11420.22282 | 13704.26738 | 0.84985 | 1.01982 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:00:00 | 25.38800 | 1.27176E-002 | 174.19320 | 28.12446 | 0.20574 | 0.00000 |
14 | SMSTORE5 | Heating | 18529.40823 | 22235.28987 | 0.83341 | 1.00010 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -32.70000 | 1.83376E-004 | 174.19320 | 28.12446 | 0.20574 | 0.00000 |
15 | SMSTORE6 | Cooling | 11358.65031 | 13630.38038 | 0.84516 | 1.01419 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:00:00 | 25.38800 | 1.27176E-002 | 174.19320 | 28.12446 | 0.20574 | 0.00000 |
16 | SMSTORE6 | Heating | 18515.77887 | 22218.93465 | 0.83280 | 0.99936 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -32.70000 | 1.83376E-004 | 174.19320 | 28.12446 | 0.20574 | 0.00000 |
17 | SMSTORE7 | Cooling | 11269.66208 | 13523.59449 | 0.83840 | 1.00608 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:00:00 | 25.38800 | 1.27176E-002 | 174.19320 | 28.12446 | 0.20574 | 0.00000 |
18 | SMSTORE7 | Heating | 18784.20979 | 22541.05175 | 0.84487 | 1.01385 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -32.70000 | 1.83376E-004 | 174.19320 | 28.12446 | 0.20574 | 0.00000 |
19 | SMSTORE8 | Cooling | 11957.03597 | 14348.44316 | 0.89098 | 1.06918 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:00:00 | 25.38800 | 1.27176E-002 | 174.19320 | 28.12446 | 0.20574 | 0.00000 |
20 | SMSTORE8 | Heating | 22970.94731 | 27565.13677 | 1.03315 | 1.23978 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -32.70000 | 1.83376E-004 | 174.19320 | 28.12446 | 0.20574 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC_1:1 | Cooling | Sensible | 29031.88 | 2.02788 | 2.02788 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
2 | PSZ-AC_1:1 | Heating | Sensible | 70038.12 | 2.02500 | 2.02500 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
3 | PSZ-AC_2:2 | Cooling | Sensible | 15251.54 | 1.07115 | 1.07115 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
4 | PSZ-AC_2:2 | Heating | Sensible | 33969.89 | 0.96461 | 0.96461 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
5 | PSZ-AC_3:3 | Cooling | Sensible | 15231.94 | 1.06963 | 1.06963 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
6 | PSZ-AC_3:3 | Heating | Sensible | 34116.78 | 0.97132 | 0.97132 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
7 | PSZ-AC_4:4 | Cooling | Sensible | 15276.14 | 1.07307 | 1.07307 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
8 | PSZ-AC_4:4 | Heating | Sensible | 34184.50 | 0.97441 | 0.97441 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
9 | PSZ-AC_5:5 | Cooling | Sensible | 15221.39 | 1.06881 | 1.06881 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
10 | PSZ-AC_5:5 | Heating | Sensible | 34345.31 | 0.98175 | 0.98175 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
11 | PSZ-AC_6:6 | Cooling | Sensible | 28301.68 | 1.97117 | 1.97117 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
12 | PSZ-AC_6:6 | Heating | Sensible | 66440.21 | 1.86081 | 1.86081 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
13 | PSZ-AC_7:7 | Cooling | Sensible | 14616.37 | 1.02250 | 1.02250 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
14 | PSZ-AC_7:7 | Heating | Sensible | 34747.22 | 1.00010 | 1.00010 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
15 | PSZ-AC_8:8 | Cooling | Sensible | 14539.04 | 1.01723 | 1.01723 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
16 | PSZ-AC_8:8 | Heating | Sensible | 34731.10 | 0.99936 | 0.99936 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
17 | PSZ-AC_9:9 | Cooling | Sensible | 14485.44 | 1.01167 | 1.01167 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
18 | PSZ-AC_9:9 | Heating | Sensible | 35048.53 | 1.01385 | 1.01385 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
19 | PSZ-AC_10:10 | Cooling | Sensible | 15271.54 | 1.08362 | 1.08362 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
20 | PSZ-AC_10:10 | Heating | Sensible | 39999.27 | 1.23978 | 1.23978 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | LGSTORE1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 2.02788 |
2 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | SMSTORE1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.07115 |
3 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | SMSTORE2 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.06963 |
4 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | SMSTORE3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.07307 |
5 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | SMSTORE4 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.06881 |
6 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | LGSTORE2 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.97117 |
7 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | SMSTORE5 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.01982 |
8 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | SMSTORE6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.01419 |
9 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | SMSTORE7 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.01385 |
10 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | SMSTORE8 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.23978 |
11 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.02788 |
12 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.02788 |
13 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.02788 |
14 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 2.02788 |
15 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.02788 |
16 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Main Design Air Flow Rate [m3/s] | 2.02788 |
17 | AirLoopHVAC | PSZ-AC_1:1 | User Heating Air Flow Ratio [] | 1.00000 |
18 | AirLoopHVAC | PSZ-AC_1:1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
19 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.07115 |
20 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.07115 |
21 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.07115 |
22 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.07115 |
23 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.07115 |
24 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Main Design Air Flow Rate [m3/s] | 1.07115 |
25 | AirLoopHVAC | PSZ-AC_2:2 | User Heating Air Flow Ratio [] | 1.00000 |
26 | AirLoopHVAC | PSZ-AC_2:2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
27 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.06963 |
28 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.06963 |
29 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.06963 |
30 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.06963 |
31 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.06963 |
32 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.06963 |
33 | AirLoopHVAC | PSZ-AC_3:3 | User Heating Air Flow Ratio [] | 1.00000 |
34 | AirLoopHVAC | PSZ-AC_3:3 | Calculated Heating Air Flow Ratio [] | 1.00000 |
35 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.07307 |
36 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.07307 |
37 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.07307 |
38 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.07307 |
39 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.07307 |
40 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Main Design Air Flow Rate [m3/s] | 1.07307 |
41 | AirLoopHVAC | PSZ-AC_4:4 | User Heating Air Flow Ratio [] | 1.00000 |
42 | AirLoopHVAC | PSZ-AC_4:4 | Calculated Heating Air Flow Ratio [] | 1.00000 |
43 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.06881 |
44 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.06881 |
45 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.06881 |
46 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.06881 |
47 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.06881 |
48 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Main Design Air Flow Rate [m3/s] | 1.06881 |
49 | AirLoopHVAC | PSZ-AC_5:5 | User Heating Air Flow Ratio [] | 1.00000 |
50 | AirLoopHVAC | PSZ-AC_5:5 | Calculated Heating Air Flow Ratio [] | 1.00000 |
51 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.97117 |
52 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.97117 |
53 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.97117 |
54 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.97117 |
55 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.97117 |
56 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Main Design Air Flow Rate [m3/s] | 1.97117 |
57 | AirLoopHVAC | PSZ-AC_6:6 | User Heating Air Flow Ratio [] | 1.00000 |
58 | AirLoopHVAC | PSZ-AC_6:6 | Calculated Heating Air Flow Ratio [] | 1.00000 |
59 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.01982 |
60 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.01982 |
61 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.01982 |
62 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.01982 |
63 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.02250 |
64 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Main Design Air Flow Rate [m3/s] | 1.02250 |
65 | AirLoopHVAC | PSZ-AC_7:7 | User Heating Air Flow Ratio [] | 1.00000 |
66 | AirLoopHVAC | PSZ-AC_7:7 | Calculated Heating Air Flow Ratio [] | 0.99738 |
67 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.01419 |
68 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.01419 |
69 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.01419 |
70 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.01419 |
71 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.01723 |
72 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Main Design Air Flow Rate [m3/s] | 1.01723 |
73 | AirLoopHVAC | PSZ-AC_8:8 | User Heating Air Flow Ratio [] | 1.00000 |
74 | AirLoopHVAC | PSZ-AC_8:8 | Calculated Heating Air Flow Ratio [] | 0.99701 |
75 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.01385 |
76 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.01385 |
77 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.01385 |
78 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.01385 |
79 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.01385 |
80 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Main Design Air Flow Rate [m3/s] | 1.01385 |
81 | AirLoopHVAC | PSZ-AC_9:9 | User Heating Air Flow Ratio [] | 1.00000 |
82 | AirLoopHVAC | PSZ-AC_9:9 | Calculated Heating Air Flow Ratio [] | 1.00000 |
83 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.23978 |
84 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.23978 |
85 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.23978 |
86 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.23978 |
87 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.23978 |
88 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Main Design Air Flow Rate [m3/s] | 1.23978 |
89 | AirLoopHVAC | PSZ-AC_10:10 | User Heating Air Flow Ratio [] | 1.00000 |
90 | AirLoopHVAC | PSZ-AC_10:10 | Calculated Heating Air Flow Ratio [] | 1.00000 |
91 | AirLoopHVAC | PSZ-AC_1:1 | Design Supply Air Flow Rate [m3/s] | 2.02788 |
92 | AirLoopHVAC | PSZ-AC_2:2 | Design Supply Air Flow Rate [m3/s] | 1.07115 |
93 | AirLoopHVAC | PSZ-AC_3:3 | Design Supply Air Flow Rate [m3/s] | 1.06963 |
94 | AirLoopHVAC | PSZ-AC_4:4 | Design Supply Air Flow Rate [m3/s] | 1.07307 |
95 | AirLoopHVAC | PSZ-AC_5:5 | Design Supply Air Flow Rate [m3/s] | 1.06881 |
96 | AirLoopHVAC | PSZ-AC_6:6 | Design Supply Air Flow Rate [m3/s] | 1.97117 |
97 | AirLoopHVAC | PSZ-AC_7:7 | Design Supply Air Flow Rate [m3/s] | 1.02250 |
98 | AirLoopHVAC | PSZ-AC_8:8 | Design Supply Air Flow Rate [m3/s] | 1.01723 |
99 | AirLoopHVAC | PSZ-AC_9:9 | Design Supply Air Flow Rate [m3/s] | 1.01385 |
100 | AirLoopHVAC | PSZ-AC_10:10 | Design Supply Air Flow Rate [m3/s] | 1.23978 |
101 | Controller:OutdoorAir | PSZ-AC_1:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.02788 |
102 | Controller:OutdoorAir | PSZ-AC_1:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.41148 |
103 | HeatExchanger:AirToAir:SensibleAndLatent | PSZ-AC_1:1 OA HEAT RECOVERY | Design Size Nominal Supply Air Flow Rate [m3/s] | 0.41148 |
104 | Fan:SystemModel | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 2.02788 |
105 | Fan:SystemModel | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2169.92306 |
106 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 2.02788 |
107 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 2.02788 |
108 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.02788 |
109 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.33840 |
110 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1 COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 2.02788 |
111 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1 COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.01394 |
112 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1 COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.35192 |
113 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1 COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 41181.84000 |
114 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1 COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 20590.92000 |
115 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1 COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.77069 |
116 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1 COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.77069 |
117 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 41181.84000 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 70101.08754 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
121 | Coil:Heating:Fuel | PSZ-AC_1:1 HEATING COIL | Design Size Nominal Capacity [W] | 70101.08754 |
122 | Controller:OutdoorAir | PSZ-AC_2:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.07115 |
123 | Controller:OutdoorAir | PSZ-AC_2:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20574 |
124 | Fan:SystemModel | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.07115 |
125 | Fan:SystemModel | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1185.93762 |
126 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.07115 |
127 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.07115 |
128 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.07115 |
129 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.70696 |
130 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2 COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.07115 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2 COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.53558 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2 COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.71410 |
133 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2 COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 21514.43000 |
134 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2 COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 10757.21500 |
135 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2 COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.77401 |
136 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2 COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.77401 |
137 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 21514.43000 |
138 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 36304.09539 |
139 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
140 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
141 | Coil:Heating:Fuel | PSZ-AC_2:2 HEATING COIL | Design Size Nominal Capacity [W] | 36304.09539 |
142 | Controller:OutdoorAir | PSZ-AC_3:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.06963 |
143 | Controller:OutdoorAir | PSZ-AC_3:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20574 |
144 | Fan:SystemModel | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.06963 |
145 | Fan:SystemModel | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1184.24883 |
146 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.06963 |
147 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.06963 |
148 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.06963 |
149 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.70595 |
150 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3 COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.06963 |
151 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3 COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.53481 |
152 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3 COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.71309 |
153 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3 COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 21490.52000 |
154 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3 COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 10745.26000 |
155 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3 COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.77391 |
156 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3 COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.77391 |
157 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 21490.52000 |
158 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 36270.67503 |
159 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
160 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
161 | Coil:Heating:Fuel | PSZ-AC_3:3 HEATING COIL | Design Size Nominal Capacity [W] | 36270.67503 |
162 | Controller:OutdoorAir | PSZ-AC_4:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.07307 |
163 | Controller:OutdoorAir | PSZ-AC_4:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20574 |
164 | Fan:SystemModel | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.07307 |
165 | Fan:SystemModel | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1188.05645 |
166 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.07307 |
167 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.07307 |
168 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.07307 |
169 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.70822 |
170 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4 COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.07307 |
171 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4 COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.53653 |
172 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4 COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.71538 |
173 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4 COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 21544.55000 |
174 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4 COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 10772.27500 |
175 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4 COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.77512 |
176 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4 COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.77512 |
177 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 21544.55000 |
178 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 36346.02199 |
179 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
180 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
181 | Coil:Heating:Fuel | PSZ-AC_4:4 HEATING COIL | Design Size Nominal Capacity [W] | 36346.02199 |
182 | Controller:OutdoorAir | PSZ-AC_5:5_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.06881 |
183 | Controller:OutdoorAir | PSZ-AC_5:5_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20574 |
184 | Fan:SystemModel | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.06881 |
185 | Fan:SystemModel | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1183.34004 |
186 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.06881 |
187 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.06881 |
188 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.06881 |
189 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.70541 |
190 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5 COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.06881 |
191 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5 COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.53440 |
192 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5 COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.71254 |
193 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5 COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 21477.64000 |
194 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5 COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 10738.82000 |
195 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5 COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.77386 |
196 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5 COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.77386 |
197 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 21477.64000 |
198 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 36252.68318 |
199 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
200 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
201 | Coil:Heating:Fuel | PSZ-AC_5:5 HEATING COIL | Design Size Nominal Capacity [W] | 36252.68318 |
202 | Controller:OutdoorAir | PSZ-AC_6:6_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.97117 |
203 | Controller:OutdoorAir | PSZ-AC_6:6_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.41148 |
204 | HeatExchanger:AirToAir:SensibleAndLatent | PSZ-AC_6:6 OA HEAT RECOVERY | Design Size Nominal Supply Air Flow Rate [m3/s] | 0.41148 |
205 | Fan:SystemModel | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.97117 |
206 | Fan:SystemModel | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2109.24889 |
207 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.97117 |
208 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.97117 |
209 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.97117 |
210 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.30097 |
211 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6 COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.97117 |
212 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6 COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.98559 |
213 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6 COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.31411 |
214 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6 COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 40165.33000 |
215 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6 COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 20082.66500 |
216 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6 COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.76868 |
217 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6 COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.76868 |
218 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 40165.33000 |
219 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 68858.04575 |
220 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
221 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
222 | Coil:Heating:Fuel | PSZ-AC_6:6 HEATING COIL | Design Size Nominal Capacity [W] | 68858.04575 |
223 | Controller:OutdoorAir | PSZ-AC_7:7_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.02250 |
224 | Controller:OutdoorAir | PSZ-AC_7:7_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20574 |
225 | Fan:SystemModel | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.02250 |
226 | Fan:SystemModel | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1132.06621 |
227 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.02250 |
228 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.02250 |
229 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.02250 |
230 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.67485 |
231 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7 COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.02250 |
232 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7 COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.51125 |
233 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7 COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.68167 |
234 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7 COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 20751.85000 |
235 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7 COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 10375.92500 |
236 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7 COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.77087 |
237 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7 COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.77087 |
238 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 20751.85000 |
239 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 35179.29968 |
240 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
241 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
242 | Coil:Heating:Fuel | PSZ-AC_7:7 HEATING COIL | Design Size Nominal Capacity [W] | 35179.29968 |
243 | Controller:OutdoorAir | PSZ-AC_8:8_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.01723 |
244 | Controller:OutdoorAir | PSZ-AC_8:8_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20574 |
245 | Fan:SystemModel | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.01723 |
246 | Fan:SystemModel | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1126.23920 |
247 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.01723 |
248 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.01723 |
249 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.01723 |
250 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.67137 |
251 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8 COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.01723 |
252 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8 COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.50862 |
253 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8 COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.67815 |
254 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8 COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 20672.17000 |
255 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8 COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 10336.08500 |
256 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8 COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.76948 |
257 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8 COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.76948 |
258 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 20672.17000 |
259 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 35056.00199 |
260 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
261 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
262 | Coil:Heating:Fuel | PSZ-AC_8:8 HEATING COIL | Design Size Nominal Capacity [W] | 35056.00199 |
263 | Controller:OutdoorAir | PSZ-AC_9:9_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.01385 |
264 | Controller:OutdoorAir | PSZ-AC_9:9_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20574 |
265 | Fan:SystemModel | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.01385 |
266 | Fan:SystemModel | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1122.49176 |
267 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.01385 |
268 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.01385 |
269 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.01385 |
270 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.66914 |
271 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9 COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.01385 |
272 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9 COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.50692 |
273 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9 COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.67590 |
274 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9 COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 20622.29000 |
275 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9 COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 10311.14500 |
276 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9 COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.76920 |
277 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9 COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.76920 |
278 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 20622.29000 |
279 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 35048.52909 |
280 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
281 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
282 | Coil:Heating:Fuel | PSZ-AC_9:9 HEATING COIL | Design Size Nominal Capacity [W] | 35048.52909 |
283 | Controller:OutdoorAir | PSZ-AC_10:10_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.23978 |
284 | Controller:OutdoorAir | PSZ-AC_10:10_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20574 |
285 | Fan:SystemModel | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.23978 |
286 | Fan:SystemModel | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1372.62930 |
287 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.23978 |
288 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.23978 |
289 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.23978 |
290 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.81825 |
291 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10 COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.23978 |
292 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10 COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.61989 |
293 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10 COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.82652 |
294 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10 COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 24839.41000 |
295 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10 COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 12419.70500 |
296 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10 COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.77576 |
297 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10 COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.77576 |
298 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 24839.41000 |
299 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 39999.27070 |
300 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
301 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
302 | Coil:Heating:Fuel | PSZ-AC_10:10 HEATING COIL | Design Size Nominal Capacity [W] | 39999.27070 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1 COOLING COIL | 39587.8 | 11.39 | 11.39 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2 COOLING COIL | 20672.6 | 11.54 | 11.54 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3 COOLING COIL | 20649.9 | 11.54 | 11.54 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4 COOLING COIL | 20701.2 | 11.54 | 11.54 | |||
5 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5 COOLING COIL | 20637.6 | 11.54 | 11.54 | |||
6 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6 COOLING COIL | 38615.8 | 11.40 | 11.40 | |||
7 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7 COOLING COIL | 19948.1 | 11.56 | 11.56 | |||
8 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8 COOLING COIL | 19872.5 | 11.56 | 11.56 | |||
9 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9 COOLING COIL | 19825.3 | 11.56 | 11.56 | |||
10 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10 COOLING COIL | 23865.1 | 11.53 | 11.53 |
Zone Name | # Surfaces | |
1 | LGSTORE1 | 15 |
2 | SMSTORE1 | 11 |
3 | SMSTORE2 | 11 |
4 | SMSTORE3 | 11 |
5 | SMSTORE4 | 11 |
6 | LGSTORE2 | 15 |
7 | SMSTORE5 | 11 |
8 | SMSTORE6 | 11 |
9 | SMSTORE7 | 11 |
10 | SMSTORE8 | 11 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | LGSTORE1_WALL_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | LGSTORE1_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 71.15 | 78.94 | 71.15 | 0.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | LGSTORE1_WALL_3_DOOR_1 | Door | LGSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
4 | LGSTORE1_WALL_3_DOOR_2 | Door | LGSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | LGSTORE1_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE1_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
6 | LGSTORE1_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 58.18 | 78.94 | 58.18 | 180.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
7 | LGSTORE1_WALL_1_WINDOW_1 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
8 | LGSTORE1_WALL_1_WINDOW_2 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
9 | LGSTORE1_WALL_1_WINDOW_3 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
10 | LGSTORE1_WALL_1_WINDOW_4 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
11 | LGSTORE1_WALL_1_DOOR_1 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
12 | LGSTORE1_WALL_1_DOOR_2 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
13 | LGSTORE1_FLOOR | Floor | CTF - ConductionTransferFunction | LGSTORE1_FLOOR_FFACTOR | 0.108 | 0.105 | 348.39 | 348.39 | 348.39 | 270.00 | 180.00 | 22.86 | 15.24 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
14 | LGSTORE1_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.163 | 0.158 | 348.39 | 348.39 | 348.39 | 270.00 | 0.00 | 22.86 | 15.24 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
15 | LGSTORE1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 696.77 | 696.77 | 696.77 | 0.00 | 90.00 | 696.77 | 1.00 | 0.00 | LGSTORE1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
16 | SMSTORE1_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 29.09 | 39.47 | 29.09 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | SMSTORE1_WALL_1_WINDOW_1 | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
18 | SMSTORE1_WALL_1_WINDOW_2 | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
19 | SMSTORE1_WALL_1_DOOR | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
20 | SMSTORE1_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE1_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | SMSTORE1_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 35.57 | 39.47 | 35.57 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
22 | SMSTORE1_WALL_3_DOOR | Door | SMSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | SMSTORE1_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE2_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
24 | SMSTORE1_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE1_FLOOR_FFACTOR | 6.115E-002 | 6.026E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
25 | SMSTORE1_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.163 | 0.158 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
26 | SMSTORE1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
27 | SMSTORE2_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 29.11 | 39.47 | 29.11 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
28 | SMSTORE2_WALL_1_WINDOW_1 | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
29 | SMSTORE2_WALL_1_WINDOW_2 | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
30 | SMSTORE2_WALL_1_DOOR | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
31 | SMSTORE2_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE1_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
32 | SMSTORE2_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | SMSTORE2_WALL_3_DOOR | Door | SMSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
34 | SMSTORE2_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE3_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | SMSTORE2_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE2_FLOOR_FFACTOR | 6.115E-002 | 6.026E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
36 | SMSTORE2_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.163 | 0.158 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
37 | SMSTORE2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
38 | SMSTORE3_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 29.11 | 39.47 | 29.11 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
39 | SMSTORE3_WALL_1_WINDOW_1 | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
40 | SMSTORE3_WALL_1_WINDOW_2 | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
41 | SMSTORE3_WALL_1_DOOR | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
42 | SMSTORE3_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE2_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
43 | SMSTORE3_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
44 | SMSTORE3_WALL_3_DOOR | Door | SMSTORE3_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
45 | SMSTORE3_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE4_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
46 | SMSTORE3_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE3_FLOOR_FFACTOR | 6.115E-002 | 6.026E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
47 | SMSTORE3_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.163 | 0.158 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
48 | SMSTORE3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
49 | SMSTORE4_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 29.11 | 39.47 | 29.11 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | SMSTORE4_WALL_1_WINDOW_1 | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
51 | SMSTORE4_WALL_1_WINDOW_2 | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
52 | SMSTORE4_WALL_1_DOOR | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
53 | SMSTORE4_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE3_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | SMSTORE4_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | SMSTORE4_WALL_3_DOOR | Door | SMSTORE4_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
56 | SMSTORE4_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE2_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | SMSTORE4_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE4_FLOOR_FFACTOR | 6.115E-002 | 6.026E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
58 | SMSTORE4_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.163 | 0.158 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
59 | SMSTORE4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
60 | LGSTORE2_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE4_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | LGSTORE2_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 71.19 | 78.94 | 71.19 | 0.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
62 | LGSTORE2_WALL_3_DOOR_1 | Door | LGSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
63 | LGSTORE2_WALL_3_DOOR_2 | Door | LGSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
64 | LGSTORE2_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE5_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | LGSTORE2_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 58.22 | 78.94 | 58.22 | 180.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
66 | LGSTORE2_WALL_1_WINDOW_1 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
67 | LGSTORE2_WALL_1_WINDOW_2 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
68 | LGSTORE2_WALL_1_WINDOW_3 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
69 | LGSTORE2_WALL_1_WINDOW_4 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | LGSTORE2_WALL_1_DOOR_1 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
71 | LGSTORE2_WALL_1_DOOR_2 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
72 | LGSTORE2_FLOOR | Floor | CTF - ConductionTransferFunction | LGSTORE2_FLOOR_FFACTOR | 6.115E-002 | 6.026E-002 | 348.39 | 348.39 | 348.39 | 270.00 | 180.00 | 22.86 | 15.24 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
73 | LGSTORE2_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.163 | 0.158 | 348.39 | 348.39 | 348.39 | 270.00 | 0.00 | 22.86 | 15.24 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
74 | LGSTORE2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 696.77 | 696.77 | 696.77 | 0.00 | 90.00 | 696.77 | 1.00 | 0.00 | LGSTORE2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
75 | SMSTORE5_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 29.11 | 39.47 | 29.11 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
76 | SMSTORE5_WALL_1_WINDOW_1 | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
77 | SMSTORE5_WALL_1_WINDOW_2 | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
78 | SMSTORE5_WALL_1_DOOR | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
79 | SMSTORE5_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE2_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | SMSTORE5_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 35.59 | 39.47 | 35.59 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | SMSTORE5_WALL_3_DOOR | Door | SMSTORE5_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
82 | SMSTORE5_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE6_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
83 | SMSTORE5_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE5_FLOOR_FFACTOR | 6.115E-002 | 6.026E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
84 | SMSTORE5_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.163 | 0.158 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
85 | SMSTORE5_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE5_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
86 | SMSTORE6_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 29.11 | 39.47 | 29.11 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | SMSTORE6_WALL_1_WINDOW_1 | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
88 | SMSTORE6_WALL_1_WINDOW_2 | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
89 | SMSTORE6_WALL_1_DOOR | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
90 | SMSTORE6_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE5_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
91 | SMSTORE6_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
92 | SMSTORE6_WALL_3_DOOR | Door | SMSTORE6_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
93 | SMSTORE6_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE7_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
94 | SMSTORE6_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE6_FLOOR_FFACTOR | 6.115E-002 | 6.026E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
95 | SMSTORE6_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.163 | 0.158 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
96 | SMSTORE6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
97 | SMSTORE7_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 29.11 | 39.47 | 29.11 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
98 | SMSTORE7_WALL_1_WINDOW_1 | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
99 | SMSTORE7_WALL_1_WINDOW_2 | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
100 | SMSTORE7_WALL_1_DOOR | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
101 | SMSTORE7_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE6_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
102 | SMSTORE7_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 35.59 | 39.47 | 35.59 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
103 | SMSTORE7_WALL_3_DOOR | Door | SMSTORE7_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
104 | SMSTORE7_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE8_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | SMSTORE7_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE7_FLOOR_FFACTOR | 6.115E-002 | 6.026E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
106 | SMSTORE7_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.163 | 0.158 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
107 | SMSTORE7_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE7_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
108 | SMSTORE8_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 29.11 | 39.47 | 29.11 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | SMSTORE8_WALL_1_WINDOW_1 | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
110 | SMSTORE8_WALL_1_WINDOW_2 | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
111 | SMSTORE8_WALL_1_DOOR | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.2917_SHGC_0.45 | N/A | 1.657 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
112 | SMSTORE8_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE7_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
113 | SMSTORE8_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
114 | SMSTORE8_WALL_3_DOOR | Door | SMSTORE8_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
115 | SMSTORE8_WALL_4 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.664 | 0.604 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
116 | SMSTORE8_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE8_FLOOR_FFACTOR | 0.155 | 0.149 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
117 | SMSTORE8_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.163 | 0.158 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
118 | SMSTORE8_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE8_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1Environment:Special Days |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | LGSTORE1 | RunPeriod: RUNPERIOD 1 | 0.1196233329 | 0.3591457374 | Pass | Pass | 0.1501209150 | 0.4226311948 | Pass | Pass |
2 | SMSTORE1 | RunPeriod: RUNPERIOD 1 | 7.5517473063E-002 | 0.3101414840 | Pass | Pass | 0.1129923200 | 0.5555503073 | Pass | Pass |
3 | SMSTORE2 | RunPeriod: RUNPERIOD 1 | 0.1047550833 | 0.3392637708 | Pass | Pass | 6.2212951166E-002 | 0.1742689141 | Pass | Pass |
4 | SMSTORE3 | RunPeriod: RUNPERIOD 1 | 0.1242464830 | 0.3505466724 | Pass | Pass | 0.1319422096 | 0.3910335580 | Pass | Pass |
5 | SMSTORE4 | RunPeriod: RUNPERIOD 1 | 0.1348582661 | 0.3391211398 | Pass | Pass | 0.2996888505 | 0.9411609881 | Pass | Pass |
6 | LGSTORE2 | RunPeriod: RUNPERIOD 1 | 0.1677315614 | 0.3735063398 | Pass | Pass | 0.2287362388 | 0.6856367607 | Pass | Pass |
7 | SMSTORE5 | RunPeriod: RUNPERIOD 1 | 0.1677319984 | 0.3569350042 | Pass | Pass | 0.2867147673 | 0.6588590334 | Pass | Pass |
8 | SMSTORE6 | RunPeriod: RUNPERIOD 1 | 0.1698828283 | 0.3577484729 | Pass | Pass | 0.3059598882 | 0.7407357744 | Pass | Pass |
9 | SMSTORE7 | RunPeriod: RUNPERIOD 1 | 0.1909643001 | 0.3672389539 | Pass | Pass | 0.3307982305 | 0.7370633310 | Pass | Pass |
10 | SMSTORE8 | RunPeriod: RUNPERIOD 1 | 0.4033071583 | 0.5642447232 | Pass | Pass | 0.2684939399 | 0.4474872674 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Heat Emission by ComponentsEnvelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
Heat Emissions [GJ] | 3631.13 | 350.27 | 0.00 | 820.16 | 475.52 | 5277.10 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | -32.70 | 0.00 | -32.70 | Wetbulb [C] | 2.40 | 210.00 |
INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 30.10 | 12.40 | 21.10 | Wetbulb [C] | 4.70 | 200.00 |
Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
Jan | 0.00 | 0 | |||
Feb | 0.00 | 0 | |||
Mar | 12.00 | 13 | |||
Apr | 16.00 | 23 | |||
May | 0.00 | 0 | |||
Jun | 190.00 | 53 | |||
Jul | 136.00 | 41 | |||
Aug | 87.00 | 42 | |||
Sep | 0.00 | 0 | |||
Oct | 0.00 | 0 | |||
Nov | 0.00 | 0 | |||
Dec | 0.00 | 0 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_2 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 118.41 | 118.41 | 270.00 | 90.00 | W |
LGSTORE1_WALL_3 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 78.94 | 71.15 | 0.00 | 90.00 | N |
LGSTORE1_WALL_1 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 78.94 | 58.18 | 180.00 | 90.00 | S |
LGSTORE1_FLOOR | LGSTORE1_FLOOR_FFACTOR | 1.00 | 0.106 | 0.108 | 348.39 | 348.39 | 270.00 | 180.00 | |
LGSTORE1_ROOF | NONRES_ROOF | 0.23 | 0.159 | 0.163 | 348.39 | 348.39 | 270.00 | 0.00 | |
SMSTORE1_WALL_1 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 39.47 | 29.09 | 180.00 | 90.00 | S |
SMSTORE1_WALL_3 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 39.47 | 35.57 | 0.00 | 90.00 | N |
SMSTORE1_FLOOR | SMSTORE1_FLOOR_FFACTOR | 1.00 | 0.061 | 0.061 | 174.19 | 174.19 | 270.00 | 180.00 | |
SMSTORE1_ROOF | NONRES_ROOF | 0.23 | 0.159 | 0.163 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE2_WALL_1 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 39.47 | 29.11 | 180.00 | 90.00 | S |
SMSTORE2_WALL_3 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE2_FLOOR | SMSTORE2_FLOOR_FFACTOR | 1.00 | 0.061 | 0.061 | 174.19 | 174.19 | 270.00 | 180.00 | |
SMSTORE2_ROOF | NONRES_ROOF | 0.23 | 0.159 | 0.163 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE3_WALL_1 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 39.47 | 29.11 | 180.00 | 90.00 | S |
SMSTORE3_WALL_3 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE3_FLOOR | SMSTORE3_FLOOR_FFACTOR | 1.00 | 0.061 | 0.061 | 174.19 | 174.19 | 270.00 | 180.00 | |
SMSTORE3_ROOF | NONRES_ROOF | 0.23 | 0.159 | 0.163 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE4_WALL_1 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 39.47 | 29.11 | 180.00 | 90.00 | S |
SMSTORE4_WALL_3 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE4_FLOOR | SMSTORE4_FLOOR_FFACTOR | 1.00 | 0.061 | 0.061 | 174.19 | 174.19 | 270.00 | 180.00 | |
SMSTORE4_ROOF | NONRES_ROOF | 0.23 | 0.159 | 0.163 | 174.19 | 174.19 | 270.00 | 0.00 | |
LGSTORE2_WALL_3 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 78.94 | 71.19 | 0.00 | 90.00 | N |
LGSTORE2_WALL_1 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 78.94 | 58.22 | 180.00 | 90.00 | S |
LGSTORE2_FLOOR | LGSTORE2_FLOOR_FFACTOR | 1.00 | 0.061 | 0.061 | 348.39 | 348.39 | 270.00 | 180.00 | |
LGSTORE2_ROOF | NONRES_ROOF | 0.23 | 0.159 | 0.163 | 348.39 | 348.39 | 270.00 | 0.00 | |
SMSTORE5_WALL_1 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 39.47 | 29.11 | 180.00 | 90.00 | S |
SMSTORE5_WALL_3 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE5_FLOOR | SMSTORE5_FLOOR_FFACTOR | 1.00 | 0.061 | 0.061 | 174.19 | 174.19 | 270.00 | 180.00 | |
SMSTORE5_ROOF | NONRES_ROOF | 0.23 | 0.159 | 0.163 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE6_WALL_1 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 39.47 | 29.11 | 180.00 | 90.00 | S |
SMSTORE6_WALL_3 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE6_FLOOR | SMSTORE6_FLOOR_FFACTOR | 1.00 | 0.061 | 0.061 | 174.19 | 174.19 | 270.00 | 180.00 | |
SMSTORE6_ROOF | NONRES_ROOF | 0.23 | 0.159 | 0.163 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE7_WALL_1 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 39.47 | 29.11 | 180.00 | 90.00 | S |
SMSTORE7_WALL_3 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE7_FLOOR | SMSTORE7_FLOOR_FFACTOR | 1.00 | 0.061 | 0.061 | 174.19 | 174.19 | 270.00 | 180.00 | |
SMSTORE7_ROOF | NONRES_ROOF | 0.23 | 0.159 | 0.163 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE8_WALL_1 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 39.47 | 29.11 | 180.00 | 90.00 | S |
SMSTORE8_WALL_3 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE8_WALL_4 | NONRES_EXT_WALL_GRD | 0.30 | 0.604 | 0.664 | 118.41 | 118.41 | 90.00 | 90.00 | E |
SMSTORE8_FLOOR | SMSTORE8_FLOOR_FFACTOR | 1.00 | 0.151 | 0.155 | 174.19 | 174.19 | 270.00 | 180.00 | |
SMSTORE8_ROOF | NONRES_ROOF | 0.23 | 0.159 | 0.163 | 174.19 | 174.19 | 270.00 | 0.00 |
Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_4 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 90.00 | 90.00 | E |
SMSTORE1_WALL_2 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 270.00 | 90.00 | W |
SMSTORE1_WALL_4 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 90.00 | 90.00 | E |
SMSTORE2_WALL_2 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 270.00 | 90.00 | W |
SMSTORE2_WALL_4 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 90.00 | 90.00 | E |
SMSTORE3_WALL_2 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 270.00 | 90.00 | W |
SMSTORE3_WALL_4 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 90.00 | 90.00 | E |
SMSTORE4_WALL_2 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 270.00 | 90.00 | W |
SMSTORE4_WALL_4 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 90.00 | 90.00 | E |
LGSTORE2_WALL_2 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 270.00 | 90.00 | W |
LGSTORE2_WALL_4 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 90.00 | 90.00 | E |
SMSTORE5_WALL_2 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 270.00 | 90.00 | W |
SMSTORE5_WALL_4 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 90.00 | 90.00 | E |
SMSTORE6_WALL_2 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 270.00 | 90.00 | W |
SMSTORE6_WALL_4 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 90.00 | 90.00 | E |
SMSTORE7_WALL_2 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 270.00 | 90.00 | W |
SMSTORE7_WALL_4 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 90.00 | 90.00 | E |
SMSTORE8_WALL_2 | INT_WALL | 0.30 | 2.511 | 6.299 | 118.41 | 118.41 | 270.00 | 90.00 | W |
LGSTORE1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 696.77 | 0.00 | 90.00 | N | ||
SMSTORE1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 348.39 | 0.00 | 90.00 | N | ||
SMSTORE2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 348.39 | 0.00 | 90.00 | N | ||
SMSTORE3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 348.39 | 0.00 | 90.00 | N | ||
SMSTORE4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 348.39 | 0.00 | 90.00 | N | ||
LGSTORE2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 696.77 | 0.00 | 90.00 | N | ||
SMSTORE5_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 348.39 | 0.00 | 90.00 | N | ||
SMSTORE6_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 348.39 | 0.00 | 90.00 | N | ||
SMSTORE7_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 348.39 | 0.00 | 90.00 | N | ||
SMSTORE8_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 348.39 | 0.00 | 90.00 | N |
Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | |||||||
LGSTORE1_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | |||||||
LGSTORE1_WALL_1_WINDOW_3 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | |||||||
LGSTORE1_WALL_1_WINDOW_4 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | |||||||
LGSTORE1_WALL_1_DOOR_1 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 1.657 | 0.451 | 0.452 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | |||||||
LGSTORE1_WALL_1_DOOR_2 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 1.657 | 0.451 | 0.452 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE1_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE1_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE1_WALL_1_DOOR | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 1.657 | 0.451 | 0.452 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE2_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE2_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE2_WALL_1_DOOR | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 1.657 | 0.451 | 0.452 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE3_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE3_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE3_WALL_1_DOOR | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 1.657 | 0.451 | 0.452 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE4_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE4_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE4_WALL_1_DOOR | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 1.657 | 0.451 | 0.452 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | |||||||
LGSTORE2_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | |||||||
LGSTORE2_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | |||||||
LGSTORE2_WALL_1_WINDOW_3 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | |||||||
LGSTORE2_WALL_1_WINDOW_4 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | |||||||
LGSTORE2_WALL_1_DOOR_1 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 1.657 | 0.451 | 0.452 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | |||||||
LGSTORE2_WALL_1_DOOR_2 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 1.657 | 0.451 | 0.452 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE5_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE5_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE5_WALL_1_DOOR | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 1.657 | 0.451 | 0.452 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE6_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE6_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE6_WALL_1_DOOR | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 1.657 | 0.451 | 0.452 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE7_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE7_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE7_WALL_1_DOOR | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 1.657 | 0.451 | 0.452 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE8_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE8_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 1.657 | 0.451 | 0.452 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | |||||||
SMSTORE8_WALL_1_DOOR | NONRESWINDOW_U_0.2917_SHGC_0.45 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 1.657 | 0.451 | 0.452 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | |||||||
Total or Average | 124.40 | 1.657 | 0.451 | 0.452 | |||||||||||||||||
North Total or Average | 0.00 | - | - | - | |||||||||||||||||
Non-North Total or Average | 124.40 | 1.657 | 0.451 | 0.452 |
Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
None |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
LGSTORE1_WALL_3_DOOR_1 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.90 | LGSTORE1_WALL_3 |
LGSTORE1_WALL_3_DOOR_2 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.90 | LGSTORE1_WALL_3 |
SMSTORE1_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.90 | SMSTORE1_WALL_3 |
SMSTORE2_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE2_WALL_3 |
SMSTORE3_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE3_WALL_3 |
SMSTORE4_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE4_WALL_3 |
LGSTORE2_WALL_3_DOOR_1 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | LGSTORE2_WALL_3 |
LGSTORE2_WALL_3_DOOR_2 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | LGSTORE2_WALL_3 |
SMSTORE5_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE5_WALL_3 |
SMSTORE6_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE6_WALL_3 |
SMSTORE7_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE7_WALL_3 |
SMSTORE8_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE8_WALL_3 |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
LGSTORE1_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_DOOR_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_DOOR_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_DOOR_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_DOOR_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Interior LightingZone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LGSTORE1_LIGHTS | LGSTORE1 | LGSTORE1 | GENERAL | 13.1942 | 348.39 | 4596.69 | LightsWired | LTG_SCH_BASE_LPD1 | 84.21 | 168.00 | 84.19 | 0.0000 | Y | 72.65 |
LGSTORE1_LIGHTS_ALLOWANCE | LGSTORE1 | LGSTORE1 | GENERAL | 4.6828 | 348.39 | 1631.41 | LightsWired | LTG_SCH_DISPLAY_LPD_TYPE3_LGSTORE | 97.50 | 168.00 | 97.48 | 0.0000 | Y | 29.85 |
SMSTORE1_LIGHTS | SMSTORE1 | SMSTORE1 | GENERAL | 13.3632 | 174.19 | 2327.78 | LightsWired | LTG_SCH_BASE_SMALL_LPD1 | 85.70 | 168.00 | 85.69 | 0.0000 | Y | 37.44 |
SMSTORE1_LIGHTS_ALLOWANCE | SMSTORE1 | SMSTORE1 | GENERAL | 5.9749 | 174.19 | 1040.80 | LightsWired | LTG_SCH_DISPLAY_LPD_TYPE3_SMSTORE | 97.50 | 168.00 | 97.48 | 0.0000 | Y | 19.04 |
SMSTORE2_LIGHTS | SMSTORE2 | SMSTORE2 | GENERAL | 13.3365 | 174.19 | 2323.12 | LightsWired | LTG_SCH_BASE_SMALL_LPD2_TYPE2 | 68.73 | 168.00 | 68.21 | 0.0000 | Y | 29.75 |
SMSTORE2_LIGHTS_ALLOWANCE | SMSTORE2 | SMSTORE2 | GENERAL | 4.0374 | 174.19 | 703.30 | LightsWired | LTG_SCH_DISPLAY_LPD_TYPE2_SMSTORE | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 10.29 |
SMSTORE3_LIGHTS | SMSTORE3 | SMSTORE3 | GENERAL | 13.3365 | 174.19 | 2323.12 | LightsWired | LTG_SCH_BASE_SMALL_LPD2_TYPE2 | 68.73 | 168.00 | 68.21 | 0.0000 | Y | 29.75 |
SMSTORE3_LIGHTS_ALLOWANCE | SMSTORE3 | SMSTORE3 | GENERAL | 4.0374 | 174.19 | 703.30 | LightsWired | LTG_SCH_DISPLAY_LPD_TYPE2_SMSTORE | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 10.29 |
SMSTORE4_LIGHTS | SMSTORE4 | SMSTORE4 | GENERAL | 13.3365 | 174.19 | 2323.12 | LightsWired | LTG_SCH_BASE_SMALL_LPD2_TYPE2 | 68.73 | 168.00 | 68.21 | 0.0000 | Y | 29.75 |
SMSTORE4_LIGHTS_ALLOWANCE | SMSTORE4 | SMSTORE4 | GENERAL | 4.0374 | 174.19 | 703.30 | LightsWired | LTG_SCH_DISPLAY_LPD_TYPE2_SMSTORE | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 10.29 |
LGSTORE2_LIGHTS | LGSTORE2 | LGSTORE2 | GENERAL | 13.1675 | 348.39 | 4587.38 | LightsWired | LTG_SCH_BASE_LPD2 | 62.11 | 168.00 | 61.60 | 0.0000 | Y | 53.05 |
LGSTORE2_LIGHTS_ALLOWANCE | LGSTORE2 | LGSTORE2 | GENERAL | 0.0000 | 348.39 | 0.00 | LightsWired | LTG_SCH_DISPLAY_LPD_TYPE1_LGSTORE | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE5_LIGHTS | SMSTORE5 | SMSTORE5 | GENERAL | 13.3365 | 174.19 | 2323.12 | LightsWired | LTG_SCH_BASE_SMALL_LPD2_TYPE3 | 63.22 | 168.00 | 62.70 | 0.0000 | Y | 27.34 |
SMSTORE5_LIGHTS_ALLOWANCE | SMSTORE5 | SMSTORE5 | GENERAL | 0.0000 | 174.19 | 0.00 | LightsWired | LTG_SCH_DISPLAY_LPD_TYPE1_SMSTORE | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE6_LIGHTS | SMSTORE6 | SMSTORE6 | GENERAL | 13.3365 | 174.19 | 2323.12 | LightsWired | LTG_SCH_BASE_SMALL_LPD2_TYPE3 | 63.22 | 168.00 | 62.70 | 0.0000 | Y | 27.34 |
SMSTORE6_LIGHTS_ALLOWANCE | SMSTORE6 | SMSTORE6 | GENERAL | 0.0000 | 174.19 | 0.00 | LightsWired | LTG_SCH_DISPLAY_LPD_TYPE1_SMSTORE | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE7_LIGHTS | SMSTORE7 | SMSTORE7 | GENERAL | 13.3365 | 174.19 | 2323.12 | LightsWired | LTG_SCH_BASE_SMALL_LPD2_TYPE3 | 63.22 | 168.00 | 62.70 | 0.0000 | Y | 27.34 |
SMSTORE7_LIGHTS_ALLOWANCE | SMSTORE7 | SMSTORE7 | GENERAL | 0.0000 | 174.19 | 0.00 | LightsWired | LTG_SCH_DISPLAY_LPD_TYPE1_SMSTORE | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE8_LIGHTS | SMSTORE8 | SMSTORE8 | GENERAL | 13.3365 | 174.19 | 2323.12 | LightsWired | LTG_SCH_BASE_SMALL_LPD2_TYPE3 | 63.22 | 168.00 | 62.70 | 0.0000 | Y | 27.34 |
SMSTORE8_LIGHTS_ALLOWANCE | SMSTORE8 | SMSTORE8 | GENERAL | 0.0000 | 174.19 | 0.00 | LightsWired | LTG_SCH_DISPLAY_LPD_TYPE1_SMSTORE | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
Interior Lighting Total | 7.7873 | 4180.64 | 32555.80 | 441.52 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 345.19 | AstronomicalClock | - | 42.55 | 42.55 | 2.76 | |
EXTERIOR_LIGHTS_B | 7274.32 | AstronomicalClock | - | 83.52 | 71.23 | 97.26 | |
Exterior Lighting Total | 7619.51 | 100.02 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Central PlantType | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC_1:1 COOLING COIL | Coil:Cooling:DX:MultiSpeed | 41181.84 | 31738.43 | 9443.41 | 0.77 | 3.73 | |||
PSZ-AC_2:2 COOLING COIL | Coil:Cooling:DX:MultiSpeed | 21514.43 | 16652.38 | 4862.05 | 0.77 | 3.80 | |||
PSZ-AC_3:3 COOLING COIL | Coil:Cooling:DX:MultiSpeed | 21490.52 | 16631.73 | 4858.79 | 0.77 | 3.80 | |||
PSZ-AC_4:4 COOLING COIL | Coil:Cooling:DX:MultiSpeed | 21544.55 | 16699.61 | 4844.94 | 0.78 | 3.80 | |||
PSZ-AC_5:5 COOLING COIL | Coil:Cooling:DX:MultiSpeed | 21477.64 | 16620.69 | 4856.95 | 0.77 | 3.80 | |||
PSZ-AC_6:6 COOLING COIL | Coil:Cooling:DX:MultiSpeed | 40165.33 | 30874.29 | 9291.04 | 0.77 | 3.73 | |||
PSZ-AC_7:7 COOLING COIL | Coil:Cooling:DX:MultiSpeed | 20751.85 | 15996.98 | 4754.87 | 0.77 | 3.80 | |||
PSZ-AC_8:8 COOLING COIL | Coil:Cooling:DX:MultiSpeed | 20672.17 | 15906.82 | 4765.35 | 0.77 | 3.80 | |||
PSZ-AC_9:9 COOLING COIL | Coil:Cooling:DX:MultiSpeed | 20622.29 | 15862.67 | 4759.62 | 0.77 | 3.80 | |||
PSZ-AC_10:10 COOLING COIL | Coil:Cooling:DX:MultiSpeed | 24839.41 | 19269.42 | 5569.99 | 0.78 | 3.80 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC_1:1 COOLING COIL | 39587.8 | 11.39 | 11.39 | ||||
PSZ-AC_2:2 COOLING COIL | 20672.6 | 11.54 | 11.54 | ||||
PSZ-AC_3:3 COOLING COIL | 20649.9 | 11.54 | 11.54 | ||||
PSZ-AC_4:4 COOLING COIL | 20701.2 | 11.54 | 11.54 | ||||
PSZ-AC_5:5 COOLING COIL | 20637.6 | 11.54 | 11.54 | ||||
PSZ-AC_6:6 COOLING COIL | 38615.8 | 11.40 | 11.40 | ||||
PSZ-AC_7:7 COOLING COIL | 19948.1 | 11.56 | 11.56 | ||||
PSZ-AC_8:8 COOLING COIL | 19872.5 | 11.56 | 11.56 | ||||
PSZ-AC_9:9 COOLING COIL | 19825.3 | 11.56 | 11.56 | ||||
PSZ-AC_10:10 COOLING COIL | 23865.1 | 11.53 | 11.53 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC_1:1 COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_2:2 COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_3:3 COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_4:4 COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_5:5 COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_6:6 COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_7:7 COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_8:8 COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_9:9 COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_10:10 COOLING COIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
PSZ-AC_1:1 HEATING COIL | Coil:Heating:Fuel | 70101.09 | 0.80 | |
PSZ-AC_2:2 HEATING COIL | Coil:Heating:Fuel | 36304.10 | 0.80 | |
PSZ-AC_3:3 HEATING COIL | Coil:Heating:Fuel | 36270.68 | 0.80 | |
PSZ-AC_4:4 HEATING COIL | Coil:Heating:Fuel | 36346.02 | 0.80 | |
PSZ-AC_5:5 HEATING COIL | Coil:Heating:Fuel | 36252.68 | 0.80 | |
PSZ-AC_6:6 HEATING COIL | Coil:Heating:Fuel | 68858.05 | 0.80 | |
PSZ-AC_7:7 HEATING COIL | Coil:Heating:Fuel | 35179.30 | 0.80 | |
PSZ-AC_8:8 HEATING COIL | Coil:Heating:Fuel | 35056.00 | 0.80 | |
PSZ-AC_9:9 HEATING COIL | Coil:Heating:Fuel | 35048.53 | 0.80 | |
PSZ-AC_10:10 HEATING COIL | Coil:Heating:Fuel | 39999.27 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 2.03 | 2169.92 | 1070.05 | 1.00 | 1.31 | General | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.07 | 1185.94 | 1107.16 | 1.00 | 1.39 | General | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.07 | 1184.25 | 1107.16 | 1.00 | 1.39 | General | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.07 | 1188.06 | 1107.16 | 1.00 | 1.39 | General | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.07 | 1183.34 | 1107.16 | 1.00 | 1.39 | General | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 1.97 | 2109.25 | 1070.05 | 1.00 | 1.32 | General | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.02 | 1132.07 | 1107.16 | 1.00 | 1.40 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:20:00 |
PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.02 | 1126.24 | 1107.16 | 1.00 | 1.40 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:20:00 |
PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.01 | 1122.49 | 1107.16 | 1.00 | 1.40 | General | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.24 | 1372.63 | 1107.16 | 1.00 | 1.35 | General | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK1 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK2 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK3 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK4 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK5 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK6 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK7 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
LGSTORE1 | 22063.62 | 26476.35 | 76.00 | 1.690 | 2.028 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 23.89 | 23.89 | 0.00958 | 30.10 | 0.01273 | 0.411 | 0.00 |
SMSTORE1 | 11654.46 | 13985.36 | 80.29 | 0.893 | 1.071 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 23.89 | 23.89 | 0.00954 | 30.10 | 0.01273 | 0.206 | 0.00 |
SMSTORE2 | 11637.87 | 13965.44 | 80.17 | 0.891 | 1.070 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 23.89 | 23.89 | 0.00954 | 30.10 | 0.01273 | 0.206 | 0.00 |
SMSTORE3 | 11675.29 | 14010.35 | 80.43 | 0.894 | 1.073 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 23.89 | 23.89 | 0.00954 | 30.10 | 0.01273 | 0.206 | 0.00 |
SMSTORE4 | 11628.94 | 13954.73 | 80.11 | 0.891 | 1.069 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 23.89 | 23.89 | 0.00954 | 30.10 | 0.01273 | 0.206 | 0.00 |
LGSTORE2 | 21447.02 | 25736.43 | 73.87 | 1.643 | 1.971 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 23.89 | 23.89 | 0.00957 | 30.00 | 0.01273 | 0.411 | 0.00 |
SMSTORE5 | 11420.22 | 13704.27 | 78.67 | 0.850 | 1.020 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:00:00 | 23.89 | 23.89 | 0.00940 | 25.39 | 0.01272 | 0.206 | 0.00 |
SMSTORE6 | 11358.65 | 13630.38 | 78.25 | 0.845 | 1.014 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:00:00 | 23.89 | 23.89 | 0.00942 | 25.39 | 0.01272 | 0.206 | 0.00 |
SMSTORE7 | 11269.66 | 13523.59 | 77.64 | 0.838 | 1.006 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:00:00 | 23.89 | 23.89 | 0.00945 | 25.39 | 0.01272 | 0.206 | 0.00 |
SMSTORE8 | 11957.04 | 14348.44 | 82.37 | 0.891 | 1.069 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:00:00 | 23.89 | 23.89 | 0.00945 | 25.39 | 0.01272 | 0.206 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
LGSTORE1 | 37518.61 | 45022.34 | 129.23 | 1.688 | 2.025 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00677 | -32.70 | 0.00018 | 0.411 | 0.00 |
SMSTORE1 | 17872.07 | 21446.48 | 123.12 | 0.804 | 0.965 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00665 | -32.70 | 0.00018 | 0.206 | 0.00 |
SMSTORE2 | 17996.29 | 21595.55 | 123.97 | 0.809 | 0.971 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00666 | -32.70 | 0.00018 | 0.206 | 0.00 |
SMSTORE3 | 18053.56 | 21664.27 | 124.37 | 0.812 | 0.974 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00666 | -32.70 | 0.00018 | 0.206 | 0.00 |
SMSTORE4 | 18189.54 | 21827.45 | 125.31 | 0.818 | 0.982 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00667 | -32.70 | 0.00018 | 0.206 | 0.00 |
LGSTORE2 | 34475.87 | 41371.04 | 118.75 | 1.551 | 1.861 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00673 | -32.70 | 0.00018 | 0.411 | 0.00 |
SMSTORE5 | 18529.41 | 22235.29 | 127.65 | 0.833 | 1.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00669 | -32.70 | 0.00018 | 0.206 | 0.00 |
SMSTORE6 | 18515.78 | 22218.93 | 127.55 | 0.833 | 0.999 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00669 | -32.70 | 0.00018 | 0.206 | 0.00 |
SMSTORE7 | 18784.21 | 22541.05 | 129.40 | 0.845 | 1.014 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00670 | -32.70 | 0.00018 | 0.206 | 0.00 |
SMSTORE8 | 22970.95 | 27565.14 | 158.24 | 1.033 | 1.240 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00682 | -32.70 | 0.00018 | 0.206 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC_1:1 | 2.03 | 2.03 | 2.03 | 2.03 | 2.0279 | 2.0279 | 2.0279 | 1.0000 | 1.0000 |
PSZ-AC_2:2 | 1.07 | 1.07 | 0.96 | 0.96 | 1.0712 | 1.0712 | 1.0712 | 1.0000 | 1.0000 |
PSZ-AC_3:3 | 1.07 | 1.07 | 0.97 | 0.97 | 1.0696 | 1.0696 | 1.0696 | 1.0000 | 1.0000 |
PSZ-AC_4:4 | 1.07 | 1.07 | 0.97 | 0.97 | 1.0731 | 1.0731 | 1.0731 | 1.0000 | 1.0000 |
PSZ-AC_5:5 | 1.07 | 1.07 | 0.98 | 0.98 | 1.0688 | 1.0688 | 1.0688 | 1.0000 | 1.0000 |
PSZ-AC_6:6 | 1.97 | 1.97 | 1.86 | 1.86 | 1.9712 | 1.9712 | 1.9712 | 1.0000 | 1.0000 |
PSZ-AC_7:7 | 1.02 | 1.02 | 1.00 | 1.00 | 1.0225 | 1.0198 | 1.0225 | 0.9974 | 1.0000 |
PSZ-AC_8:8 | 1.02 | 1.02 | 1.00 | 1.00 | 1.0172 | 1.0142 | 1.0172 | 0.9970 | 1.0000 |
PSZ-AC_9:9 | 1.01 | 1.01 | 1.01 | 1.01 | 1.0138 | 1.0138 | 1.0138 | 1.0000 | 1.0000 |
PSZ-AC_10:10 | 1.08 | 1.08 | 1.24 | 1.24 | 1.2398 | 1.2398 | 1.2398 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
PSZ-AC_1:1 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_1:1 | 41181.840 | 31738.432 | 2.027880 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 20590.92 | 16039.94 | 1.351920 | 26.05 | 18.05 | 0.01021483 | 12.80 | 11.72 | 0.00850000 | 30.10 | 0.01272586 | 21.13 | 30.4366 | 23.89 | 0.00957561 | 49.6511 | 22063.62 | 0.00 | -999.00 | -999.00 |
PSZ-AC_1:1 HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_1:1 | 70101.088 | 70101.088 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 70101.09 | 70101.09 | 2.027876 | 10.19 | 7.29 | 0.00542990 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 20.2911 | 21.10 | 0.00676549 | 41.7311 | 37518.61 | 0.00 | -999.00 | -999.00 |
PSZ-AC_2:2 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_2:2 | 21514.430 | 16652.384 | 1.071150 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 10757.22 | 8446.80 | 0.714100 | 26.02 | 17.98 | 0.01014930 | 12.80 | 11.72 | 0.00850000 | 30.10 | 0.01272586 | 21.13 | 28.8110 | 23.89 | 0.00953676 | 49.4524 | 11654.46 | 0.00 | -999.00 | -999.00 |
PSZ-AC_2:2 HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_2:2 | 36304.095 | 36304.095 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 36304.10 | 36304.10 | 1.071154 | 10.77 | 7.54 | 0.00540769 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 19.2073 | 21.10 | 0.00664969 | 41.0248 | 17872.07 | 0.00 | -999.00 | -999.00 |
PSZ-AC_3:3 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_3:3 | 21490.520 | 16631.728 | 1.069630 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 10745.26 | 8435.50 | 0.713087 | 26.02 | 17.99 | 0.01015122 | 12.80 | 11.72 | 0.00850000 | 30.10 | 0.01272586 | 21.13 | 28.8520 | 23.89 | 0.00953806 | 49.4590 | 11637.87 | 0.00 | -999.00 | -999.00 |
PSZ-AC_3:3 HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_3:3 | 36270.675 | 36270.675 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 36270.68 | 36270.68 | 1.069629 | 10.76 | 7.53 | 0.00541157 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 19.2347 | 21.10 | 0.00665669 | 41.0675 | 17996.29 | 0.00 | -999.00 | -999.00 |
PSZ-AC_4:4 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_4:4 | 21544.550 | 16699.612 | 1.073070 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 10772.27 | 8460.97 | 0.715380 | 26.01 | 17.98 | 0.01014694 | 12.80 | 11.72 | 0.00850000 | 30.10 | 0.01272586 | 21.13 | 28.7595 | 23.89 | 0.00953519 | 49.4444 | 11675.29 | 0.00 | -999.00 | -999.00 |
PSZ-AC_4:4 HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_4:4 | 36346.022 | 36346.022 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 36346.02 | 36346.02 | 1.073068 | 10.79 | 7.56 | 0.00541815 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 19.1730 | 21.10 | 0.00665990 | 41.0871 | 18053.56 | 0.00 | -999.00 | -999.00 |
PSZ-AC_5:5 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_5:5 | 21477.640 | 16620.686 | 1.068810 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 10738.82 | 8429.43 | 0.712540 | 26.02 | 17.99 | 0.01015225 | 12.80 | 11.72 | 0.00850000 | 30.10 | 0.01272586 | 21.13 | 28.8741 | 23.89 | 0.00953875 | 49.4626 | 11628.94 | 0.00 | -999.00 | -999.00 |
PSZ-AC_5:5 HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_5:5 | 36252.683 | 36252.683 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 36252.68 | 36252.68 | 1.068808 | 10.75 | 7.54 | 0.00541933 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 19.2494 | 21.10 | 0.00666748 | 41.1334 | 18189.54 | 0.00 | -999.00 | -999.00 |
PSZ-AC_6:6 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_6:6 | 40165.330 | 30874.286 | 1.971170 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 20082.67 | 15623.61 | 1.314113 | 26.09 | 18.07 | 0.01022908 | 12.80 | 11.72 | 0.00850000 | 30.10 | 0.01272586 | 21.13 | 31.3123 | 23.89 | 0.00957033 | 49.6238 | 21445.63 | 0.00 | -999.00 | -999.00 |
PSZ-AC_6:6 HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_6:6 | 68858.046 | 68858.046 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 68858.05 | 68858.05 | 1.971174 | 9.87 | 7.06 | 0.00536377 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 20.8748 | 21.10 | 0.00673046 | 41.5163 | 34475.87 | 0.00 | -999.00 | -999.00 |
PSZ-AC_7:7 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_7:7 | 20751.850 | 15996.979 | 1.022500 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:20:00 | 10375.92 | 8086.83 | 0.681667 | 26.07 | 18.05 | 0.01021328 | 12.80 | 11.72 | 0.00850000 | 30.10 | 0.01272586 | 21.13 | 30.1818 | 23.89 | 0.00957978 | 49.6721 | 11116.85 | 0.00 | -999.00 | -999.00 |
PSZ-AC_7:7 HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_7:7 | 35179.300 | 35179.300 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 35179.30 | 35179.30 | 1.022497 | 10.28 | 7.27 | 0.00537759 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 20.1213 | 21.10 | 0.00668600 | 41.2464 | 18529.41 | 0.00 | -999.00 | -999.00 |
PSZ-AC_8:8 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_8:8 | 20672.170 | 15906.821 | 1.017230 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:20:00 | 10336.08 | 8048.23 | 0.678153 | 26.08 | 18.06 | 0.01022140 | 12.80 | 11.72 | 0.00850000 | 30.10 | 0.01272586 | 21.13 | 30.3382 | 23.89 | 0.00958525 | 49.7000 | 11051.39 | 0.00 | -999.00 | -999.00 |
PSZ-AC_8:8 HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_8:8 | 35056.002 | 35056.002 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 35056.00 | 35056.00 | 1.017234 | 10.22 | 7.23 | 0.00537023 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 20.2254 | 21.10 | 0.00668526 | 41.2419 | 18515.78 | 0.00 | -999.00 | -999.00 |
PSZ-AC_9:9 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_9:9 | 20622.290 | 15862.665 | 1.013850 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 10311.15 | 8023.55 | 0.675900 | 26.09 | 18.07 | 0.01022707 | 12.80 | 11.72 | 0.00850000 | 30.10 | 0.01272586 | 21.13 | 30.4393 | 23.89 | 0.00958908 | 49.7196 | 11006.03 | 0.00 | -999.00 | -999.00 |
PSZ-AC_9:9 HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_9:9 | 35048.529 | 35048.529 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 35048.53 | 35048.53 | 1.013849 | 10.19 | 7.23 | 0.00537723 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 20.2929 | 21.10 | 0.00669956 | 41.3292 | 18784.21 | 0.00 | -999.00 | -999.00 |
PSZ-AC_10:10 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_10:10 | 24839.410 | 19269.421 | 1.239780 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:00:00 | 12419.70 | 9697.36 | 0.826520 | 25.93 | 17.98 | 0.01018286 | 12.80 | 11.72 | 0.00850000 | 29.69 | 0.01272514 | 21.01 | 24.8922 | 23.89 | 0.00958485 | 49.6985 | 11754.88 | 0.00 | -999.00 | -999.00 |
PSZ-AC_10:10 HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_10:10 | 39999.271 | 39999.271 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 39999.27 | 39999.27 | 1.239776 | 12.18 | 8.53 | 0.00571683 | 40.00 | 20.69 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 16.5949 | 21.10 | 0.00681780 | 42.0525 | 22970.95 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
PSZ-AC_1:1 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_1:1 | LGSTORE1 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 41181.840 | 31738.432 | 2.027880 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.8289 | 1004.8586 | 1.1539 | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 2.027876 | 2.34001639 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | Sensible | 20590.92 | 16039.94 | 1.0000 | 1.56001409 | 1.351920 | 26.05 | 18.05 | 0.01021483 | 52219.9 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 20590.92 | 30.10 | 0.01272586 | 21.13 | 0.41147883 | 30.4366 | 23.89 | 0.00957561 | 23.89 | 0.00957561 | 49.6511 | 22063.62 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_1:1 HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_1:1 | LGSTORE1 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 70101.088 | 70101.088 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 2.027876 | 2.34001639 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | Sensible | 70101.09 | 70101.09 | 1.0000 | 2.34001639 | 2.027876 | 10.19 | 7.29 | 0.00542990 | 23919.3 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 70101.09 | -32.70 | 0.00018338 | -32.70 | 0.41147883 | 20.2911 | 21.10 | 0.00676549 | 21.10 | 0.00676549 | 41.7311 | 37518.61 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_2:2 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_2:2 | SMSTORE1 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 21514.430 | 16652.384 | 1.071150 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.7070 | 1004.8586 | 1.1539 | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.071154 | 1.23603134 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | Sensible | 10757.22 | 8446.80 | 1.0000 | 0.82401774 | 0.714100 | 26.02 | 17.98 | 0.01014930 | 52016.3 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10757.22 | 30.10 | 0.01272586 | 21.13 | 0.20573941 | 28.8110 | 23.89 | 0.00953676 | 23.89 | 0.00953676 | 49.4524 | 11654.46 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_2:2 HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_2:2 | SMSTORE1 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 36304.095 | 36304.095 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.071154 | 1.23603134 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | Sensible | 36304.10 | 36304.10 | 1.0000 | 1.23603134 | 1.071154 | 10.77 | 7.54 | 0.00540769 | 24455.2 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 36304.10 | -32.70 | 0.00018338 | -32.70 | 0.20573941 | 19.2073 | 21.10 | 0.00664969 | 21.10 | 0.00664969 | 41.0248 | 17872.07 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_3:3 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_3:3 | SMSTORE2 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 21490.520 | 16631.728 | 1.069630 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.7106 | 1004.8586 | 1.1539 | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.069629 | 1.23427122 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | Sensible | 10745.26 | 8435.50 | 1.0000 | 0.82284843 | 0.713087 | 26.02 | 17.99 | 0.01015122 | 52022.9 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10745.26 | 30.10 | 0.01272586 | 21.13 | 0.20573941 | 28.8520 | 23.89 | 0.00953806 | 23.89 | 0.00953806 | 49.4590 | 11637.87 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_3:3 HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_3:3 | SMSTORE2 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 36270.675 | 36270.675 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.069629 | 1.23427122 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | Sensible | 36270.68 | 36270.68 | 1.0000 | 1.23427122 | 1.069629 | 10.76 | 7.53 | 0.00541157 | 24450.1 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 36270.68 | -32.70 | 0.00018338 | -32.70 | 0.20573941 | 19.2347 | 21.10 | 0.00665669 | 21.10 | 0.00665669 | 41.0675 | 17996.29 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_4:4 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_4:4 | SMSTORE3 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 21544.550 | 16699.612 | 1.073070 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.7026 | 1004.8586 | 1.1539 | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.073068 | 1.23823967 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | Sensible | 10772.27 | 8460.97 | 1.0000 | 0.82549476 | 0.715380 | 26.01 | 17.98 | 0.01014694 | 52008.1 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10772.27 | 30.10 | 0.01272586 | 21.13 | 0.20573941 | 28.7595 | 23.89 | 0.00953519 | 23.89 | 0.00953519 | 49.4444 | 11675.29 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_4:4 HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_4:4 | SMSTORE3 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 36346.022 | 36346.022 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.073068 | 1.23823967 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | Sensible | 36346.02 | 36346.02 | 1.0000 | 1.23823967 | 1.073068 | 10.79 | 7.56 | 0.00541815 | 24500.3 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 36346.02 | -32.70 | 0.00018338 | -32.70 | 0.20573941 | 19.1730 | 21.10 | 0.00665990 | 21.10 | 0.00665990 | 41.0871 | 18053.56 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_5:5 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_5:5 | SMSTORE4 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 21477.640 | 16620.686 | 1.068810 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.7125 | 1004.8586 | 1.1539 | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.068808 | 1.23332404 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | Sensible | 10738.82 | 8429.43 | 1.0000 | 0.82221762 | 0.712540 | 26.02 | 17.99 | 0.01015225 | 52026.5 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10738.82 | 30.10 | 0.01272586 | 21.13 | 0.20573941 | 28.8741 | 23.89 | 0.00953875 | 23.89 | 0.00953875 | 49.4626 | 11628.94 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_5:5 HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_5:5 | SMSTORE4 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 36252.683 | 36252.683 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.068808 | 1.23332404 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | Sensible | 36252.68 | 36252.68 | 1.0000 | 1.23332404 | 1.068808 | 10.75 | 7.54 | 0.00541933 | 24461.5 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 36252.68 | -32.70 | 0.00018338 | -32.70 | 0.20573941 | 19.2494 | 21.10 | 0.00666748 | 21.10 | 0.00666748 | 41.1334 | 18189.54 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_6:6 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_6:6 | LGSTORE2 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 40165.330 | 30874.286 | 1.971170 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.8554 | 1004.8586 | 1.1539 | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.971174 | 2.27458617 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | Sensible | 20082.67 | 15623.61 | 1.0000 | 1.51638804 | 1.314113 | 26.09 | 18.07 | 0.01022908 | 52293.6 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 20082.67 | 30.10 | 0.01272586 | 21.13 | 0.41147883 | 31.3123 | 23.89 | 0.00957033 | 23.89 | 0.00957033 | 49.6238 | 21445.63 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_6:6 HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_6:6 | LGSTORE2 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 68858.046 | 68858.046 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.971174 | 2.27458617 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | Sensible | 68858.05 | 68858.05 | 1.0000 | 2.27458617 | 1.971174 | 9.87 | 7.06 | 0.00536377 | 23434.3 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 68858.05 | -32.70 | 0.00018338 | -32.70 | 0.41147883 | 20.8748 | 21.11 | 0.00673046 | 21.10 | 0.00673046 | 41.5163 | 34475.87 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_7:7 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_7:7 | SMSTORE5 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 20751.850 | 15996.979 | 1.022500 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.8260 | 1004.8586 | 1.1539 | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.022497 | 1.17988441 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:20:00 | Sensible | 10375.92 | 8086.83 | 1.0000 | 0.78659211 | 0.681667 | 26.07 | 18.05 | 0.01021328 | 52238.4 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10375.92 | 30.10 | 0.01272586 | 21.13 | 0.20573941 | 30.1818 | 23.89 | 0.00957978 | 23.89 | 0.00957978 | 49.6721 | 11116.85 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_7:7 HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_7:7 | SMSTORE5 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 35179.300 | 35179.300 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.022497 | 1.17988441 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | Sensible | 35179.30 | 35179.30 | 1.0000 | 1.17988441 | 1.022497 | 10.28 | 7.27 | 0.00537759 | 23880.3 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 35179.30 | -32.70 | 0.00018338 | -32.70 | 0.20573941 | 20.1213 | 21.11 | 0.00668600 | 21.10 | 0.00668600 | 41.2464 | 18529.41 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_8:8 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_8:8 | SMSTORE6 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 20672.170 | 15906.821 | 1.017230 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.8411 | 1004.8586 | 1.1539 | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.017234 | 1.17381127 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:20:00 | Sensible | 10336.08 | 8048.23 | 1.0000 | 0.78253799 | 0.678153 | 26.08 | 18.06 | 0.01022140 | 52266.6 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10336.08 | 30.10 | 0.01272586 | 21.13 | 0.20573941 | 30.3382 | 23.89 | 0.00958525 | 23.89 | 0.00958525 | 49.7000 | 11051.39 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_8:8 HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_8:8 | SMSTORE6 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 35056.002 | 35056.002 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.017234 | 1.17381127 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | Sensible | 35056.00 | 35056.00 | 1.0000 | 1.17381127 | 1.017234 | 10.22 | 7.23 | 0.00537023 | 23804.9 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 35056.00 | -32.70 | 0.00018338 | -32.70 | 0.20573941 | 20.2254 | 21.11 | 0.00668526 | 21.10 | 0.00668526 | 41.2419 | 18515.78 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_9:9 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_9:9 | SMSTORE7 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 20622.290 | 15862.665 | 1.013850 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.8516 | 1004.8586 | 1.1539 | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.013849 | 1.16990554 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | Sensible | 10311.15 | 8023.55 | 1.0000 | 0.77993781 | 0.675900 | 26.09 | 18.07 | 0.01022707 | 52286.4 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10311.15 | 30.10 | 0.01272586 | 21.13 | 0.20573941 | 30.4393 | 23.89 | 0.00958908 | 23.89 | 0.00958908 | 49.7196 | 11006.03 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_9:9 HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_9:9 | SMSTORE7 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 35048.529 | 35048.529 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.013849 | 1.16990554 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | Sensible | 35048.53 | 35048.53 | 1.0000 | 1.16990554 | 1.013849 | 10.19 | 7.23 | 0.00537723 | 23785.7 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 35048.53 | -32.70 | 0.00018338 | -32.70 | 0.20573941 | 20.2929 | 21.11 | 0.00669956 | 21.10 | 0.00669956 | 41.3292 | 18784.21 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_10:10 COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_10:10 | SMSTORE8 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 24839.410 | 19269.421 | 1.239780 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.7694 | 1004.8586 | 1.1539 | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.239776 | 1.43060883 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:00:00 | Sensible | 12419.70 | 9697.36 | 1.0000 | 0.95374197 | 0.826520 | 25.93 | 17.98 | 0.01018286 | 52010.9 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12419.70 | 29.69 | 0.01272514 | 21.01 | 0.20573941 | 24.8922 | 23.89 | 0.00958485 | 23.89 | 0.00958485 | 49.6985 | 11754.88 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_10:10 HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_10:10 | SMSTORE8 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 39999.271 | 39999.271 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.239776 | 1.43060883 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | Sensible | 39999.27 | 39999.27 | 1.0000 | 1.43060883 | 1.239776 | 12.18 | 8.53 | 0.00571683 | 26661.3 | 40.00 | 20.69 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 39999.27 | -32.70 | 0.00018338 | -32.70 | 0.20573941 | 16.5949 | 21.10 | 0.00681780 | 21.10 | 0.00681780 | 42.0525 | 22970.95 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-AC_1:1_OA_CONTROLLER | DifferentialDryBulb | 0.41 | 2.03 | - | |||
PSZ-AC_2:2_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.07 | - | |||
PSZ-AC_3:3_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.07 | - | |||
PSZ-AC_4:4_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.07 | - | |||
PSZ-AC_5:5_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.07 | - | |||
PSZ-AC_6:6_OA_CONTROLLER | DifferentialDryBulb | 0.41 | 1.97 | - | |||
PSZ-AC_7:7_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.02 | - | |||
PSZ-AC_8:8_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.02 | - | |||
PSZ-AC_9:9_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.01 | - | |||
PSZ-AC_10:10_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.24 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
LGSTORE1 | 3784.00 | 3953.33 | 2529.33 |
SMSTORE1 | 3266.33 | 3928.50 | 1969.33 |
SMSTORE2 | 2700.50 | 3118.50 | 1786.83 |
SMSTORE3 | 2737.50 | 3143.67 | 1835.17 |
SMSTORE4 | 2779.67 | 3161.50 | 1898.17 |
LGSTORE2 | 2624.33 | 2762.33 | 1762.50 |
SMSTORE5 | 2609.67 | 2961.83 | 1881.33 |
SMSTORE6 | 2619.67 | 3007.17 | 1922.33 |
SMSTORE7 | 2681.33 | 3074.33 | 2028.50 |
SMSTORE8 | 2853.17 | 3174.67 | 2275.83 |
Facility | 4407.17 | 4570.17 | 3193.00 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
LGSTORE1 | 11.67 | 0.00 | 0.00 | 0.00 |
SMSTORE1 | 6.33 | 0.00 | 0.00 | 0.00 |
SMSTORE2 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE3 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE4 | 0.00 | 0.00 | 0.00 | 0.00 |
LGSTORE2 | 1.00 | 0.17 | 0.00 | 0.17 |
SMSTORE5 | 0.67 | 0.00 | 0.00 | 0.00 |
SMSTORE6 | 0.83 | 0.00 | 0.00 | 0.00 |
SMSTORE7 | 3.33 | 0.00 | 0.00 | 0.00 |
SMSTORE8 | 130.67 | 0.00 | 0.00 | 0.00 |
Facility | 146.50 | 0.17 | 0.00 | 0.17 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
LGSTORE1 | 16.92 | 56.25 | 1805.20 | 0.997 | 0.237 | 0.000 | 0.000 |
SMSTORE1 | 8.46 | 28.12 | 902.60 | 0.853 | 0.252 | 0.000 | 0.000 |
SMSTORE2 | 7.10 | 28.12 | 902.60 | 1.036 | 0.329 | 0.000 | 0.000 |
SMSTORE3 | 7.10 | 28.12 | 902.60 | 1.034 | 0.329 | 0.000 | 0.000 |
SMSTORE4 | 7.10 | 28.12 | 902.60 | 1.029 | 0.329 | 0.000 | 0.000 |
LGSTORE2 | 24.82 | 56.25 | 1805.20 | 1.018 | 0.317 | 0.000 | 0.000 |
SMSTORE5 | 12.41 | 28.12 | 902.60 | 1.023 | 0.351 | 0.000 | 0.000 |
SMSTORE6 | 12.41 | 28.12 | 902.60 | 1.016 | 0.351 | 0.000 | 0.000 |
SMSTORE7 | 12.41 | 28.12 | 902.60 | 1.004 | 0.351 | 0.000 | 0.000 |
SMSTORE8 | 12.41 | 28.12 | 902.60 | 1.040 | 0.372 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
LGSTORE1 | 16.92 | 56.25 | 1805.20 | 0.000 | 0.000 | 0.000 | 0.000 |
SMSTORE1 | 8.46 | 28.12 | 902.60 | 0.000 | 0.000 | 0.000 | 0.000 |
SMSTORE2 | 7.10 | 28.12 | 902.60 | 0.797 | 0.000 | 0.000 | 0.000 |
SMSTORE3 | 7.10 | 28.12 | 902.60 | 0.797 | 0.000 | 0.000 | 0.000 |
SMSTORE4 | 7.10 | 28.12 | 902.60 | 0.797 | 0.000 | 0.000 | 0.000 |
LGSTORE2 | 24.82 | 56.25 | 1805.20 | 0.797 | 0.000 | 0.000 | 0.000 |
SMSTORE5 | 12.41 | 28.12 | 902.60 | 0.797 | 0.000 | 0.000 | 0.000 |
SMSTORE6 | 12.41 | 28.12 | 902.60 | 0.797 | 0.000 | 0.000 | 0.000 |
SMSTORE7 | 12.41 | 28.12 | 902.60 | 0.797 | 0.000 | 0.000 | 0.000 |
SMSTORE8 | 12.41 | 28.12 | 902.60 | 0.797 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Mechanical Ventilation Parameters by ZoneAirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
LGSTORE1 | PSZ-AC_1:1 | 16.92 | 56.25 | 1805.20 | 348.39 | 0.4115 | 0.411 |
SMSTORE1 | PSZ-AC_2:2 | 8.46 | 28.12 | 902.60 | 174.19 | 0.2057 | 0.206 |
SMSTORE2 | PSZ-AC_3:3 | 7.10 | 28.12 | 902.60 | 174.19 | 0.2057 | 0.206 |
SMSTORE3 | PSZ-AC_4:4 | 7.10 | 28.12 | 902.60 | 174.19 | 0.2057 | 0.206 |
SMSTORE4 | PSZ-AC_5:5 | 7.10 | 28.12 | 902.60 | 174.19 | 0.2057 | 0.206 |
LGSTORE2 | PSZ-AC_6:6 | 24.82 | 56.25 | 1805.20 | 348.39 | 0.4115 | 0.411 |
SMSTORE5 | PSZ-AC_7:7 | 12.41 | 28.12 | 902.60 | 174.19 | 0.2057 | 0.206 |
SMSTORE6 | PSZ-AC_8:8 | 12.41 | 28.12 | 902.60 | 174.19 | 0.2057 | 0.206 |
SMSTORE7 | PSZ-AC_9:9 | 12.41 | 28.12 | 902.60 | 174.19 | 0.2057 | 0.206 |
SMSTORE8 | PSZ-AC_10:10 | 12.41 | 28.12 | 902.60 | 174.19 | 0.2057 | 0.206 |
Total Facility | 121.13 | 337.50 | 10831.20 | 2090.32 | 2.4689 | 2.469 |
Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
LGSTORE1 | 10328871.46 | 0.00 | 10328871.46 | 2824003.76 | 13152875.22 | 12976396.34 | 3179.36 | 4211.30 | 1369.34 | 0.00 |
SMSTORE1 | 4420184.97 | 0.00 | 4420184.97 | 1417423.17 | 5837608.14 | 6488198.17 | 4348.71 | 3103.54 | 1307.75 | 0.00 |
SMSTORE2 | 4044203.69 | 0.00 | 4044203.69 | 1450589.24 | 5494792.93 | 6488198.17 | 4365.00 | 3508.57 | 886.43 | 0.00 |
SMSTORE3 | 4037802.08 | 0.00 | 4037802.08 | 1450589.24 | 5488391.32 | 6488198.17 | 4365.00 | 3523.35 | 871.65 | 0.00 |
SMSTORE4 | 4016153.86 | 0.00 | 4016153.86 | 1450589.24 | 5466743.10 | 6488198.17 | 4365.00 | 3539.27 | 855.73 | 0.00 |
LGSTORE2 | 7283019.40 | 0.00 | 7283019.40 | 2662612.36 | 9945631.76 | 12976396.34 | 4730.00 | 3179.94 | 850.06 | 0.00 |
SMSTORE5 | 3660492.37 | 0.00 | 3660492.37 | 1460886.51 | 5121378.88 | 6488198.17 | 4730.00 | 3225.82 | 804.18 | 0.00 |
SMSTORE6 | 3636067.85 | 0.00 | 3636067.85 | 1460886.51 | 5096954.36 | 6488198.17 | 4730.00 | 3247.25 | 782.75 | 0.00 |
SMSTORE7 | 3594443.06 | 0.00 | 3594443.06 | 1460886.51 | 5055329.57 | 6488198.17 | 4730.00 | 3284.09 | 745.91 | 0.00 |
SMSTORE8 | 3724076.76 | 0.00 | 3724076.76 | 1774399.60 | 5498476.35 | 6488198.17 | 4730.00 | 3344.74 | 685.26 | 0.00 |
Total Facility | 48745315.49 | 0.00 | 48745315.49 | 17412866.15 | 66158181.64 | 77858378.04 | 4730.00 | 4788.82 | 1537.45 | 0.00 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
LGSTORE1 | 0.4913 | 0.0000 | 0.4913 | 0.1172 | 0.6085 | 0.4115 | 259.36 | 4211.30 | 1369.34 |
SMSTORE1 | 0.2102 | 0.0000 | 0.2102 | 0.0624 | 0.2726 | 0.2057 | 1428.71 | 3103.54 | 1307.75 |
SMSTORE2 | 0.2556 | 0.0000 | 0.2556 | 0.0815 | 0.3371 | 0.2057 | 0.00 | 3508.57 | 886.43 |
SMSTORE3 | 0.2552 | 0.0000 | 0.2552 | 0.0815 | 0.3367 | 0.2057 | 0.00 | 3523.35 | 871.65 |
SMSTORE4 | 0.2538 | 0.0000 | 0.2538 | 0.0815 | 0.3353 | 0.2057 | 0.00 | 3539.27 | 855.73 |
LGSTORE2 | 0.5020 | 0.0000 | 0.5020 | 0.1564 | 0.6584 | 0.4115 | 0.00 | 3179.94 | 850.06 |
SMSTORE5 | 0.2523 | 0.0000 | 0.2523 | 0.0869 | 0.3392 | 0.2057 | 0.00 | 3225.82 | 804.18 |
SMSTORE6 | 0.2506 | 0.0000 | 0.2506 | 0.0869 | 0.3375 | 0.2057 | 0.00 | 3247.25 | 782.75 |
SMSTORE7 | 0.2478 | 0.0000 | 0.2478 | 0.0869 | 0.3346 | 0.2057 | 0.00 | 3284.09 | 745.91 |
SMSTORE8 | 0.2567 | 0.0000 | 0.2567 | 0.0919 | 0.3486 | 0.2057 | 0.00 | 3344.74 | 685.26 |
Total Facility | 2.9756 | 0.0000 | 2.9756 | 0.9329 | 3.9084 | 2.4689 | 1533.63 | 4788.82 | 1537.45 |
Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
PSZ-AC_1:1 | 13753151.68 | 0.00 | 13753151.68 | 12976396.34 | 3178.70 | 0.00 | 5581.30 | 0.00 |
PSZ-AC_2:2 | 5885960.69 | 0.00 | 5885960.69 | 6488198.17 | 4288.85 | 3.17 | 4467.98 | 0.00 |
PSZ-AC_3:3 | 5385328.47 | 0.00 | 5385328.47 | 6488198.17 | 4365.00 | 0.00 | 4395.00 | 0.00 |
PSZ-AC_4:4 | 5376795.01 | 0.00 | 5376795.01 | 6488198.17 | 4365.00 | 0.00 | 4395.00 | 0.00 |
PSZ-AC_5:5 | 5347964.68 | 0.00 | 5347964.68 | 6488198.17 | 4365.00 | 0.00 | 4395.00 | 0.00 |
PSZ-AC_6:6 | 9697533.57 | 0.00 | 9697533.57 | 12976396.34 | 4730.00 | 0.00 | 4030.00 | 0.00 |
PSZ-AC_7:7 | 4874366.39 | 0.00 | 4874366.39 | 6488198.17 | 4730.00 | 0.00 | 4030.00 | 0.00 |
PSZ-AC_8:8 | 4841835.21 | 0.00 | 4841835.21 | 6488198.17 | 4730.00 | 0.00 | 4030.00 | 0.00 |
PSZ-AC_9:9 | 4786391.01 | 0.00 | 4786391.01 | 6488198.17 | 4730.00 | 0.00 | 4030.00 | 0.00 |
PSZ-AC_10:10 | 4958885.09 | 0.00 | 4958885.09 | 6488198.17 | 4730.00 | 0.00 | 4030.00 | 0.00 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
PSZ-AC_1:1 | 0.6542 | 0.0000 | 0.6542 | 0.4115 | 258.70 | 0.00 | 5581.30 |
PSZ-AC_2:2 | 0.2800 | 0.0000 | 0.2800 | 0.2057 | 1368.85 | 3.17 | 4467.98 |
PSZ-AC_3:3 | 0.3404 | 0.0000 | 0.3404 | 0.2057 | 0.00 | 0.00 | 4395.00 |
PSZ-AC_4:4 | 0.3398 | 0.0000 | 0.3398 | 0.2057 | 0.00 | 0.00 | 4395.00 |
PSZ-AC_5:5 | 0.3380 | 0.0000 | 0.3380 | 0.2057 | 0.00 | 0.00 | 4395.00 |
PSZ-AC_6:6 | 0.6684 | 0.0000 | 0.6684 | 0.4115 | 0.00 | 0.00 | 4030.00 |
PSZ-AC_7:7 | 0.3360 | 0.0000 | 0.3360 | 0.2057 | 0.00 | 0.00 | 4030.00 |
PSZ-AC_8:8 | 0.3337 | 0.0000 | 0.3337 | 0.2057 | 0.00 | 0.00 | 4030.00 |
PSZ-AC_9:9 | 0.3299 | 0.0000 | 0.3299 | 0.2057 | 0.00 | 0.00 | 4030.00 |
PSZ-AC_10:10 | 0.3418 | 0.0000 | 0.3418 | 0.2057 | 0.00 | 0.00 | 4030.00 |
No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
PSZ-AC_1:1 | 0.00 | 5074.71 | 517.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PSZ-AC_2:2 | 0.00 | 4265.73 | 716.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PSZ-AC_3:3 | 0.00 | 4138.26 | 256.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PSZ-AC_4:4 | 0.00 | 4142.65 | 252.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PSZ-AC_5:5 | 0.00 | 4143.37 | 251.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PSZ-AC_6:6 | 0.00 | 3787.99 | 242.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PSZ-AC_7:7 | 0.00 | 3814.22 | 215.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PSZ-AC_8:8 | 0.00 | 3820.08 | 209.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PSZ-AC_9:9 | 0.00 | 3816.83 | 213.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PSZ-AC_10:10 | 0.00 | 3787.83 | 242.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
PSZ-AC_1:1 | 0.0000 | 0.6683 | 0.8302 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
PSZ-AC_2:2 | 0.0000 | 0.3235 | 0.3564 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
PSZ-AC_3:3 | 0.0000 | 0.3327 | 0.4652 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
PSZ-AC_4:4 | 0.0000 | 0.3321 | 0.4684 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
PSZ-AC_5:5 | 0.0000 | 0.3303 | 0.4674 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
PSZ-AC_6:6 | 0.0000 | 0.6555 | 0.8732 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
PSZ-AC_7:7 | 0.0000 | 0.3291 | 0.4604 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
PSZ-AC_8:8 | 0.0000 | 0.3269 | 0.4597 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
PSZ-AC_9:9 | 0.0000 | 0.3231 | 0.4537 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
PSZ-AC_10:10 | 0.0000 | 0.3314 | 0.5055 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Surfaces by ClassTotal | Outdoors | |
Wall | 40 | 22 |
Floor | 10 | 10 |
Roof | 10 | 10 |
Internal Mass | 10 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 36 | 36 |
Door | 12 | 12 |
Glass Door | 12 | 12 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 10 |
Conditioned Zones | 10 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 763 |
Defaulted Fields | 823 |
Fields with Defaults | 2721 |
Autosized Fields | 186 |
Autosizable Fields | 460 |
Autocalculated Fields | 128 |
Autocalculatable Fields | 256 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 913.55 | 3115.94 | 05-FEB-07:50 | 97695.45 | 29-JUN-16:30 |
Electricity:Building | 570.24 | 1897.94 | 01-JAN-00:10 | 35612.10 | 01-JAN-11:10 |
Electricity:Zone:LGSTORE1 | 128.86 | 354.96 | 01-JAN-00:10 | 6669.68 | 01-JAN-10:10 |
Electricity:SpaceType:GENERAL | 570.24 | 1897.94 | 01-JAN-00:10 | 35612.10 | 01-JAN-11:10 |
InteriorLights:Electricity | 441.52 | 1448.52 | 01-JAN-00:10 | 27522.57 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:LGSTORE1 | 102.50 | 280.06 | 01-JAN-00:10 | 5321.43 | 01-JAN-10:10 |
InteriorLights:Electricity:SpaceType:GENERAL | 441.52 | 1448.52 | 01-JAN-00:10 | 27522.57 | 01-JAN-11:10 |
LightsWired:InteriorLights:Electricity | 441.52 | 1448.52 | 01-JAN-00:10 | 27522.57 | 01-JAN-11:10 |
LightsWired:InteriorLights:Electricity:Zone:LGSTORE1 | 102.50 | 280.06 | 01-JAN-00:10 | 5321.43 | 01-JAN-10:10 |
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 441.52 | 1448.52 | 01-JAN-00:10 | 27522.57 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE1 | 69.66 | 191.80 | 01-JAN-00:10 | 3606.70 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE1 | 56.49 | 154.35 | 01-JAN-00:10 | 2932.57 | 01-JAN-10:10 |
LightsWired:InteriorLights:Electricity:Zone:SMSTORE1 | 56.49 | 154.35 | 01-JAN-00:10 | 2932.57 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE2 | 50.51 | 174.25 | 01-JAN-00:10 | 3273.35 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE2 | 40.04 | 136.80 | 01-JAN-00:10 | 2599.23 | 01-JAN-10:10 |
LightsWired:InteriorLights:Electricity:Zone:SMSTORE2 | 40.04 | 136.80 | 01-JAN-00:10 | 2599.23 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE3 | 50.51 | 174.25 | 01-JAN-00:10 | 3273.35 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE3 | 40.04 | 136.80 | 01-JAN-00:10 | 2599.23 | 01-JAN-10:10 |
LightsWired:InteriorLights:Electricity:Zone:SMSTORE3 | 40.04 | 136.80 | 01-JAN-00:10 | 2599.23 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE4 | 50.51 | 174.25 | 01-JAN-00:10 | 3273.35 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE4 | 40.04 | 136.80 | 01-JAN-00:10 | 2599.23 | 01-JAN-10:10 |
LightsWired:InteriorLights:Electricity:Zone:SMSTORE4 | 40.04 | 136.80 | 01-JAN-00:10 | 2599.23 | 01-JAN-10:10 |
Electricity:Zone:LGSTORE2 | 72.31 | 272.07 | 01-JAN-00:10 | 5094.77 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:LGSTORE2 | 53.05 | 197.17 | 01-JAN-00:10 | 3746.51 | 01-JAN-11:10 |
LightsWired:InteriorLights:Electricity:Zone:LGSTORE2 | 53.05 | 197.17 | 01-JAN-00:10 | 3746.51 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE5 | 36.97 | 139.09 | 01-JAN-00:10 | 2605.22 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE5 | 27.34 | 101.64 | 01-JAN-00:10 | 1931.10 | 01-JAN-11:10 |
LightsWired:InteriorLights:Electricity:Zone:SMSTORE5 | 27.34 | 101.64 | 01-JAN-00:10 | 1931.10 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE6 | 36.97 | 139.09 | 01-JAN-00:10 | 2605.22 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE6 | 27.34 | 101.64 | 01-JAN-00:10 | 1931.10 | 01-JAN-11:10 |
LightsWired:InteriorLights:Electricity:Zone:SMSTORE6 | 27.34 | 101.64 | 01-JAN-00:10 | 1931.10 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE7 | 36.97 | 139.09 | 01-JAN-00:10 | 2605.22 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE7 | 27.34 | 101.64 | 01-JAN-00:10 | 1931.10 | 01-JAN-11:10 |
LightsWired:InteriorLights:Electricity:Zone:SMSTORE7 | 27.34 | 101.64 | 01-JAN-00:10 | 1931.10 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE8 | 36.97 | 139.09 | 01-JAN-00:10 | 2605.22 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE8 | 27.34 | 101.64 | 01-JAN-00:10 | 1931.10 | 01-JAN-11:10 |
LightsWired:InteriorLights:Electricity:Zone:SMSTORE8 | 27.34 | 101.64 | 01-JAN-00:10 | 1931.10 | 01-JAN-11:10 |
InteriorEquipment:Electricity | 128.72 | 449.42 | 01-JAN-00:10 | 8089.53 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:LGSTORE1 | 26.36 | 74.90 | 01-JAN-00:10 | 1348.26 | 01-JAN-10:10 |
InteriorEquipment:Electricity:SpaceType:GENERAL | 128.72 | 449.42 | 01-JAN-00:10 | 8089.53 | 01-JAN-11:10 |
MiscPlug:InteriorEquipment:Electricity | 128.72 | 449.42 | 01-JAN-00:10 | 8089.53 | 01-JAN-11:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:LGSTORE1 | 26.36 | 74.90 | 01-JAN-00:10 | 1348.26 | 01-JAN-10:10 |
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 128.72 | 449.42 | 01-JAN-00:10 | 8089.53 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE1 | 13.18 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:SMSTORE1 | 13.18 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE2 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:SMSTORE2 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE3 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:SMSTORE3 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE4 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:SMSTORE4 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:LGSTORE2 | 19.26 | 74.90 | 01-JAN-00:10 | 1348.26 | 01-JAN-11:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:LGSTORE2 | 19.26 | 74.90 | 01-JAN-00:10 | 1348.26 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE5 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:SMSTORE5 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE6 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:SMSTORE6 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE7 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:SMSTORE7 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE8 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:SMSTORE8 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
ElectricityPurchased:Facility | 913.55 | 3115.94 | 05-FEB-07:50 | 97695.45 | 29-JUN-16:30 |
ElectricityPurchased:Plant | 913.55 | 3115.94 | 05-FEB-07:50 | 97695.45 | 29-JUN-16:30 |
Cogeneration:ElectricityPurchased | 913.55 | 3115.94 | 05-FEB-07:50 | 97695.45 | 29-JUN-16:30 |
General:Cogeneration:ElectricityPurchased | 913.55 | 3115.94 | 05-FEB-07:50 | 97695.45 | 29-JUN-16:30 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 913.55 | 3115.94 | 05-FEB-07:50 | 97695.45 | 29-JUN-16:30 |
ElectricityNet:Plant | 913.55 | 3115.94 | 05-FEB-07:50 | 97695.45 | 29-JUN-16:30 |
Cogeneration:ElectricityNet | 913.55 | 3115.94 | 05-FEB-07:50 | 97695.45 | 29-JUN-16:30 |
General:Cogeneration:ElectricityNet | 913.55 | 3115.94 | 05-FEB-07:50 | 97695.45 | 29-JUN-16:30 |
Electricity:HVAC | 175.81 | 0.00 | 03-JAN-01:40 | 53626.20 | 29-JUN-16:10 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 56.78 | 0.00 | 01-JAN-00:10 | 44729.40 | 29-JUN-16:10 |
General:Cooling:Electricity | 56.78 | 0.00 | 01-JAN-00:10 | 44729.40 | 29-JUN-16:10 |
Fans:Electricity | 109.86 | 0.00 | 03-JAN-01:40 | 11214.04 | 06-JAN-09:10 |
General:Fans:Electricity | 109.86 | 0.00 | 03-JAN-01:40 | 11214.04 | 06-JAN-09:10 |
ExteriorLights:Electricity | 100.02 | 0.00 | 01-JAN-08:20 | 7619.51 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 100.02 | 0.00 | 01-JAN-08:20 | 7619.51 | 01-JAN-06:10 |
HeatRecovery:Electricity | 9.17 | 0.00 | 01-JAN-00:10 | 690.47 | 30-JAN-19:40 |
General:HeatRecovery:Electricity | 9.17 | 0.00 | 01-JAN-00:10 | 690.47 | 30-JAN-19:40 |
Electricity:Plant | 67.48 | 1218.00 | 01-JAN-08:10 | 13283.29 | 09-OCT-16:50 |
WaterSystems:Electricity | 67.48 | 1218.00 | 01-JAN-08:10 | 13283.29 | 09-OCT-16:50 |
Water Heater:WaterSystems:Electricity | 67.48 | 1218.00 | 01-JAN-08:10 | 13283.29 | 09-OCT-16:50 |
Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
NaturalGas:Facility | 946.15 | 0.00 | 03-JAN-01:40 | 371004.11 | 06-JAN-09:10 |
NaturalGas:HVAC | 946.15 | 0.00 | 03-JAN-01:40 | 371004.11 | 06-JAN-09:10 |
Heating:NaturalGas | 946.15 | 0.00 | 03-JAN-01:40 | 371004.11 | 06-JAN-09:10 |
General:Heating:NaturalGas | 946.15 | 0.00 | 03-JAN-01:40 | 371004.11 | 06-JAN-09:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water:Plant | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
WaterSystems:Water | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water Heater:WaterSystems:Water | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
MainsWater:Facility | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
MainsWater:Plant | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
WaterSystems:MainsWater | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water Heater:WaterSystems:MainsWater | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
EnergyTransfer:Facility | 1796.25 | 0.00 | 03-JAN-01:40 | 442519.17 | 06-JAN-09:10 |
EnergyTransfer:Building | 622.96 | 0.00 | 03-JAN-01:40 | 156073.49 | 09-JAN-08:10 |
EnergyTransfer:Zone:LGSTORE1 | 115.96 | 0.00 | 01-JAN-00:10 | 28049.75 | 14-JAN-09:10 |
Heating:EnergyTransfer | 345.80 | 0.00 | 03-JAN-01:40 | 156059.30 | 09-JAN-08:10 |
Heating:EnergyTransfer:Zone:LGSTORE1 | 58.80 | 0.00 | 01-JAN-00:10 | 27895.90 | 06-JAN-09:10 |
General:Heating:EnergyTransfer | 345.80 | 0.00 | 03-JAN-01:40 | 156059.30 | 09-JAN-08:10 |
General:Heating:EnergyTransfer:Zone:LGSTORE1 | 58.80 | 0.00 | 01-JAN-00:10 | 27895.90 | 06-JAN-09:10 |
Cooling:EnergyTransfer | 277.16 | 0.00 | 01-JAN-00:10 | 90932.20 | 30-JUN-13:00 |
Cooling:EnergyTransfer:Zone:LGSTORE1 | 57.16 | 0.00 | 01-JAN-00:10 | 21088.51 | 06-JAN-00:10 |
General:Cooling:EnergyTransfer | 277.16 | 0.00 | 01-JAN-00:10 | 90932.20 | 30-JUN-13:00 |
General:Cooling:EnergyTransfer:Zone:LGSTORE1 | 57.16 | 0.00 | 01-JAN-00:10 | 21088.51 | 06-JAN-00:10 |
EnergyTransfer:Zone:SMSTORE1 | 55.74 | 0.00 | 01-JAN-00:10 | 13006.96 | 25-DEC-09:10 |
Heating:EnergyTransfer:Zone:SMSTORE1 | 20.40 | 0.00 | 01-JAN-00:10 | 12348.29 | 25-DEC-09:10 |
General:Heating:EnergyTransfer:Zone:SMSTORE1 | 20.40 | 0.00 | 01-JAN-00:10 | 12348.29 | 25-DEC-09:10 |
Cooling:EnergyTransfer:Zone:SMSTORE1 | 35.34 | 0.00 | 01-JAN-00:10 | 9083.54 | 27-AUG-17:30 |
General:Cooling:EnergyTransfer:Zone:SMSTORE1 | 35.34 | 0.00 | 01-JAN-00:10 | 9083.54 | 27-AUG-17:30 |
EnergyTransfer:Zone:SMSTORE2 | 48.83 | 0.00 | 01-JAN-00:10 | 14676.42 | 09-JAN-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE2 | 23.79 | 0.00 | 01-JAN-00:10 | 14676.42 | 09-JAN-08:10 |
General:Heating:EnergyTransfer:Zone:SMSTORE2 | 23.79 | 0.00 | 01-JAN-00:10 | 14676.42 | 09-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE2 | 25.04 | 0.00 | 01-JAN-00:10 | 7728.28 | 30-JUN-13:00 |
General:Cooling:EnergyTransfer:Zone:SMSTORE2 | 25.04 | 0.00 | 01-JAN-00:10 | 7728.28 | 30-JUN-13:00 |
EnergyTransfer:Zone:SMSTORE3 | 49.48 | 0.00 | 01-JAN-00:10 | 14990.78 | 09-JAN-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE3 | 25.07 | 0.00 | 01-JAN-00:10 | 14990.78 | 09-JAN-08:10 |
General:Heating:EnergyTransfer:Zone:SMSTORE3 | 25.07 | 0.00 | 01-JAN-00:10 | 14990.78 | 09-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE3 | 24.41 | 0.00 | 01-JAN-00:10 | 7747.77 | 30-JUN-13:00 |
General:Cooling:EnergyTransfer:Zone:SMSTORE3 | 24.41 | 0.00 | 01-JAN-00:10 | 7747.77 | 30-JUN-13:00 |
EnergyTransfer:Zone:SMSTORE4 | 50.51 | 0.00 | 01-JAN-00:10 | 15360.69 | 09-JAN-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE4 | 26.91 | 0.00 | 01-JAN-00:10 | 15360.69 | 09-JAN-08:10 |
General:Heating:EnergyTransfer:Zone:SMSTORE4 | 26.91 | 0.00 | 01-JAN-00:10 | 15360.69 | 09-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE4 | 23.60 | 0.00 | 01-JAN-00:10 | 7640.04 | 30-JUN-13:00 |
General:Cooling:EnergyTransfer:Zone:SMSTORE4 | 23.60 | 0.00 | 01-JAN-00:10 | 7640.04 | 30-JUN-13:00 |
EnergyTransfer:Zone:LGSTORE2 | 86.00 | 0.00 | 01-JAN-00:10 | 27204.21 | 09-JAN-09:10 |
Heating:EnergyTransfer:Zone:LGSTORE2 | 49.82 | 0.00 | 01-JAN-00:10 | 27034.02 | 09-JAN-09:10 |
General:Heating:EnergyTransfer:Zone:LGSTORE2 | 49.82 | 0.00 | 01-JAN-00:10 | 27034.02 | 09-JAN-09:10 |
Cooling:EnergyTransfer:Zone:LGSTORE2 | 36.18 | 0.00 | 01-JAN-00:10 | 14535.47 | 30-JUN-14:50 |
General:Cooling:EnergyTransfer:Zone:LGSTORE2 | 36.18 | 0.00 | 01-JAN-00:10 | 14535.47 | 30-JUN-14:50 |
EnergyTransfer:Zone:SMSTORE5 | 48.52 | 0.00 | 01-JAN-00:10 | 14447.67 | 09-JAN-09:10 |
Heating:EnergyTransfer:Zone:SMSTORE5 | 27.62 | 0.00 | 01-JAN-00:10 | 14447.67 | 09-JAN-09:10 |
General:Heating:EnergyTransfer:Zone:SMSTORE5 | 27.62 | 0.00 | 01-JAN-00:10 | 14447.67 | 09-JAN-09:10 |
Cooling:EnergyTransfer:Zone:SMSTORE5 | 20.90 | 0.00 | 01-JAN-00:10 | 7586.69 | 30-JUN-15:00 |
General:Cooling:EnergyTransfer:Zone:SMSTORE5 | 20.90 | 0.00 | 01-JAN-00:10 | 7586.69 | 30-JUN-15:00 |
EnergyTransfer:Zone:SMSTORE6 | 48.12 | 0.00 | 01-JAN-00:10 | 14472.19 | 09-JAN-09:10 |
Heating:EnergyTransfer:Zone:SMSTORE6 | 28.14 | 0.00 | 01-JAN-00:10 | 14472.19 | 09-JAN-09:10 |
General:Heating:EnergyTransfer:Zone:SMSTORE6 | 28.14 | 0.00 | 01-JAN-00:10 | 14472.19 | 09-JAN-09:10 |
Cooling:EnergyTransfer:Zone:SMSTORE6 | 19.98 | 0.00 | 01-JAN-00:10 | 7526.96 | 30-JUN-15:00 |
General:Cooling:EnergyTransfer:Zone:SMSTORE6 | 19.98 | 0.00 | 01-JAN-00:10 | 7526.96 | 30-JUN-15:00 |
EnergyTransfer:Zone:SMSTORE7 | 49.45 | 0.00 | 01-JAN-00:10 | 14836.71 | 09-JAN-09:10 |
Heating:EnergyTransfer:Zone:SMSTORE7 | 31.09 | 0.00 | 01-JAN-00:10 | 14836.71 | 09-JAN-09:10 |
General:Heating:EnergyTransfer:Zone:SMSTORE7 | 31.09 | 0.00 | 01-JAN-00:10 | 14836.71 | 09-JAN-09:10 |
Cooling:EnergyTransfer:Zone:SMSTORE7 | 18.35 | 0.00 | 01-JAN-00:10 | 7455.94 | 30-JUN-15:00 |
General:Cooling:EnergyTransfer:Zone:SMSTORE7 | 18.35 | 0.00 | 01-JAN-00:10 | 7455.94 | 30-JUN-15:00 |
EnergyTransfer:Zone:SMSTORE8 | 70.36 | 0.00 | 01-JAN-00:40 | 18935.83 | 09-JAN-09:10 |
Heating:EnergyTransfer:Zone:SMSTORE8 | 54.16 | 0.00 | 01-JAN-00:40 | 18935.83 | 09-JAN-09:10 |
General:Heating:EnergyTransfer:Zone:SMSTORE8 | 54.16 | 0.00 | 01-JAN-00:40 | 18935.83 | 09-JAN-09:10 |
Cooling:EnergyTransfer:Zone:SMSTORE8 | 16.19 | 0.00 | 01-JAN-00:10 | 8022.29 | 30-JUN-13:00 |
General:Cooling:EnergyTransfer:Zone:SMSTORE8 | 16.19 | 0.00 | 01-JAN-00:10 | 8022.29 | 30-JUN-13:00 |
EnergyTransfer:HVAC | 1173.29 | 0.00 | 03-JAN-01:40 | 296803.29 | 06-JAN-09:10 |
HeatingCoils:EnergyTransfer | 756.92 | 0.00 | 03-JAN-01:40 | 296803.29 | 06-JAN-09:10 |
CoolingCoils:EnergyTransfer | 229.52 | 0.00 | 01-JAN-00:10 | 177384.87 | 30-JUN-13:00 |
HeatRecoveryForHeating:EnergyTransfer | 179.25 | 0.00 | 01-JAN-00:10 | 31318.00 | 27-JAN-20:50 |
HeatRecoveryForCooling:EnergyTransfer | 7.60 | 0.00 | 01-JAN-00:10 | 15510.23 | 29-JUN-16:00 |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
LGSTORE1 | 0.000 | 0.000 | 58.797 | -57.162 | 0.000 | 0.000 | 25.299 | 102.498 | 26.357 | 26.660 | 0.000 | 0.869 | 0.003 | 0.000 | -11.698 | 0.000 | -57.068 | -114.552 |
SMSTORE1 | 0.000 | 0.000 | 20.396 | -35.340 | 0.000 | 0.000 | 12.685 | 56.486 | 13.179 | 13.258 | 0.000 | 0.470 | 0.001 | 0.000 | -6.029 | 0.000 | -28.139 | -46.966 |
SMSTORE2 | 0.000 | 0.000 | 23.792 | -25.035 | 0.000 | 0.000 | 7.703 | 40.039 | 10.467 | 13.238 | 0.000 | 0.464 | 0.001 | 0.000 | -5.945 | 0.000 | -28.795 | -35.929 |
SMSTORE3 | 0.000 | 0.000 | 25.070 | -24.410 | 0.000 | 0.000 | 7.709 | 40.039 | 10.467 | 13.250 | 0.000 | 0.464 | 0.000 | 0.000 | -5.898 | 0.000 | -28.740 | -37.952 |
SMSTORE4 | 0.000 | 0.000 | 26.907 | -23.603 | 0.000 | 0.000 | 7.711 | 40.039 | 10.467 | 13.260 | 0.000 | 0.464 | 0.000 | 0.000 | -5.867 | 0.000 | -28.707 | -40.672 |
LGSTORE2 | 0.000 | 0.000 | 49.820 | -36.183 | 0.000 | 0.000 | 26.167 | 53.048 | 19.261 | 26.570 | 0.000 | 0.836 | 0.000 | 0.000 | -11.577 | 0.000 | -53.173 | -74.769 |
SMSTORE5 | 0.000 | 0.000 | 27.621 | -20.902 | 0.000 | 0.000 | 13.236 | 27.343 | 9.631 | 13.289 | 0.000 | 0.465 | 0.001 | 0.000 | -5.777 | 0.000 | -28.816 | -36.089 |
SMSTORE6 | 0.000 | 0.000 | 28.144 | -19.976 | 0.000 | 0.000 | 13.254 | 27.343 | 9.631 | 13.304 | 0.000 | 0.465 | 0.000 | 0.000 | -5.750 | 0.000 | -28.761 | -37.654 |
SMSTORE7 | 0.000 | 0.000 | 31.094 | -18.353 | 0.000 | 0.000 | 13.280 | 27.343 | 9.631 | 13.335 | 0.000 | 0.465 | 0.001 | 0.000 | -5.676 | 0.000 | -28.649 | -42.469 |
SMSTORE8 | 0.000 | 0.000 | 54.164 | -16.192 | 0.000 | 0.000 | 13.321 | 27.343 | 9.631 | 13.430 | 0.000 | 0.489 | 0.000 | 0.000 | -5.382 | 0.000 | -35.019 | -61.784 |
Total Facility | 0.000 | 0.000 | 345.804 | -277.155 | 0.000 | 0.000 | 140.365 | 441.522 | 128.721 | 159.593 | 0.000 | 5.451 | 0.007 | 0.000 | -69.600 | 0.000 | -345.867 | -528.835 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
LGSTORE1 | 06-JUL-08:62 | 0.00 | 0.00 | 0.00 | -36309.96 | 0.00 | 0.00 | 180.92 | 2800.74 | 749.03 | 1048.51 | 0.00 | 0.00 | 31882.75 | 0.00 | -0.00 | 0.00 | -351.98 | 0.00 |
SMSTORE1 | 07-JUN-08:62 | 0.00 | 0.00 | 0.00 | -22189.39 | 0.00 | 0.00 | 88.61 | 1543.46 | 374.52 | 516.51 | 0.00 | 0.00 | 19765.70 | 0.00 | -0.00 | 0.00 | -99.42 | 0.00 |
SMSTORE2 | 02-SEP-07:02 | 0.00 | 0.00 | 0.00 | -22040.70 | 0.00 | 0.00 | 87.61 | 1368.01 | 374.52 | 65.64 | 0.00 | 0.00 | 20380.70 | 0.00 | -0.00 | 0.00 | -235.78 | 0.00 |
SMSTORE3 | 02-SEP-07:02 | 0.00 | 0.00 | 0.00 | -22118.38 | 0.00 | 0.00 | 87.55 | 1368.01 | 374.52 | 65.51 | 0.00 | 0.00 | 20458.66 | 0.00 | -0.00 | 0.00 | -235.87 | 0.00 |
SMSTORE4 | 02-SEP-07:02 | 0.00 | 0.00 | 0.00 | -21920.30 | 0.00 | 0.00 | 88.31 | 1368.01 | 374.52 | 66.75 | 0.00 | 0.00 | 20256.51 | 0.00 | -0.00 | 0.00 | -233.81 | 0.00 |
LGSTORE2 | 01-JUL-08:62 | 0.00 | 0.00 | 0.00 | -36094.45 | 0.00 | 0.00 | 385.20 | 1971.84 | 749.03 | 843.71 | 0.00 | 0.00 | 32400.63 | 0.00 | -0.00 | 0.00 | -255.97 | 0.00 |
SMSTORE5 | 06-JUL-08:62 | 0.00 | 0.00 | 0.00 | -18464.44 | 0.00 | 0.00 | 196.74 | 1016.37 | 374.52 | 518.49 | 0.00 | 0.00 | 16524.22 | 0.00 | -0.00 | 0.00 | -165.88 | 0.00 |
SMSTORE6 | 06-JUL-08:62 | 0.00 | 0.00 | 0.00 | -18311.16 | 0.00 | 0.00 | 197.70 | 1016.37 | 374.52 | 519.42 | 0.00 | 0.00 | 16367.65 | 0.00 | -0.00 | 0.00 | -164.48 | 0.00 |
SMSTORE7 | 01-JUL-08:62 | 0.00 | 0.00 | 0.00 | -18068.09 | 0.00 | 0.00 | 197.72 | 1016.37 | 374.52 | 425.65 | 0.00 | 0.00 | 16189.45 | 0.00 | -0.00 | 0.00 | -135.61 | 0.00 |
SMSTORE8 | 24-JUL-08:61 | 0.00 | 0.00 | 0.00 | -17706.10 | 0.00 | 0.00 | 185.01 | 1016.37 | 374.52 | 440.75 | 0.00 | 0.00 | 15756.48 | 0.00 | -0.00 | 0.00 | -67.03 | 0.00 |
Total Facility | 01-JUL-08:62 | 0.00 | 0.00 | 0.00 | -171860.18 | 0.00 | 0.00 | 2032.07 | 18179.18 | 5393.02 | 5130.87 | 0.00 | 0.00 | 142715.53 | 0.00 | 0.00 | 0.00 | -1590.50 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
LGSTORE1 | 05-JAN-00:42 | 0.00 | 0.00 | 70374.75 | 0.00 | 0.00 | 0.00 | 0.00 | 280.06 | 74.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1487.57 | 0.00 | -3181.59 | -66060.56 |
SMSTORE1 | 21-DEC-08:61 | 0.00 | 0.00 | 36217.35 | 0.00 | 0.00 | 0.00 | 138.72 | 154.35 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -587.91 | 0.00 | -1162.04 | -34797.92 |
SMSTORE2 | 19-DEC-07:01 | 0.00 | 0.00 | 36141.75 | 0.00 | 0.00 | 0.00 | 0.00 | 136.80 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -624.97 | 0.00 | -194.88 | -35496.15 |
SMSTORE3 | 19-DEC-07:01 | 0.00 | 0.00 | 36215.19 | 0.00 | 0.00 | 0.00 | 0.00 | 136.80 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -620.31 | 0.00 | -193.52 | -35575.62 |
SMSTORE4 | 19-DEC-07:01 | 0.00 | 0.00 | 36151.28 | 0.00 | 0.00 | 0.00 | 0.00 | 136.80 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -623.34 | 0.00 | -195.93 | -35506.26 |
LGSTORE2 | 25-DEC-09:01 | 0.00 | 0.00 | 68915.50 | 0.00 | 0.00 | 0.00 | 0.00 | 197.17 | 74.90 | 1466.61 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -2223.20 | -68430.98 |
SMSTORE5 | 25-DEC-09:01 | 0.00 | 0.00 | 35228.46 | 0.00 | 0.00 | 0.00 | 0.00 | 101.64 | 37.45 | 729.35 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -1221.13 | -34875.77 |
SMSTORE6 | 25-DEC-09:01 | 0.00 | 0.00 | 35110.93 | 0.00 | 0.00 | 0.00 | 0.00 | 101.64 | 37.45 | 729.56 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -1221.04 | -34758.53 |
SMSTORE7 | 13-JAN-08:61 | 0.00 | 0.00 | 35072.14 | 0.00 | 0.00 | 0.00 | 0.00 | 101.64 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -32.87 | 0.00 | -1210.32 | -33968.04 |
SMSTORE8 | 25-DEC-09:01 | 0.00 | 0.00 | 40063.97 | 0.00 | 0.00 | 0.00 | 0.00 | 101.64 | 37.45 | 746.81 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -1460.09 | -39489.78 |
Total Facility | 27-DEC-08:61 | 0.00 | 0.00 | 407511.36 | 0.00 | 0.00 | 0.00 | 815.06 | 5142.15 | 1460.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -4649.04 | 0.00 | -9495.63 | -400784.52 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC_1:1 | 2.0279 | 0.0000 | 56.2505 | 1.0000 | Calculated from schedules | 0.4115 | 2.0279 | 0.2029 | 1.0000 | Not calculated | 0.4115 | 0.2029 | ||
PSZ-AC_2:2 | 1.0712 | 0.0000 | 28.1245 | 1.0000 | Calculated from schedules | 0.2057 | 1.0712 | 0.1921 | 1.0000 | Not calculated | 0.2057 | 0.1921 | ||
PSZ-AC_3:3 | 1.0696 | 0.0000 | 28.1245 | 1.0000 | Calculated from schedules | 0.2057 | 1.0696 | 0.1923 | 1.0000 | Not calculated | 0.2057 | 0.1923 | ||
PSZ-AC_4:4 | 1.0731 | 0.0000 | 28.1245 | 1.0000 | Calculated from schedules | 0.2057 | 1.0731 | 0.1917 | 1.0000 | Not calculated | 0.2057 | 0.1917 | ||
PSZ-AC_5:5 | 1.0688 | 0.0000 | 28.1245 | 1.0000 | Calculated from schedules | 0.2057 | 1.0688 | 0.1925 | 1.0000 | Not calculated | 0.2057 | 0.1925 | ||
PSZ-AC_6:6 | 1.9712 | 0.0000 | 56.2505 | 1.0000 | Calculated from schedules | 0.4115 | 1.9712 | 0.2087 | 1.0000 | Not calculated | 0.4115 | 0.2087 | ||
PSZ-AC_7:7 | 1.0198 | 0.0000 | 28.1245 | 1.0000 | Calculated from schedules | 0.2057 | 1.0225 | 0.2012 | 1.0000 | Not calculated | 0.2057 | 0.2012 | ||
PSZ-AC_8:8 | 1.0142 | 0.0000 | 28.1245 | 1.0000 | Calculated from schedules | 0.2057 | 1.0172 | 0.2023 | 1.0000 | Not calculated | 0.2057 | 0.2023 | ||
PSZ-AC_9:9 | 1.0138 | 0.0000 | 28.1245 | 1.0000 | Calculated from schedules | 0.2057 | 1.0138 | 0.2034 | 1.0000 | Not calculated | 0.2057 | 0.2029 | ||
PSZ-AC_10:10 | 1.2398 | 0.0000 | 28.1245 | 1.0000 | Calculated from schedules | 0.2057 | 1.2398 | 0.1899 | 1.0000 | Not calculated | 0.2057 | 0.1659 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC_1:1 | 2.0279 | 0.0000 | 56.2505 | 1.0000 | Calculated from schedules | 0.4115 | 2.0279 | 1.0000 | 1.0000 | Not calculated | 0.4115 | 0.2029 | ||
PSZ-AC_2:2 | 1.0712 | 0.0000 | 28.1245 | 1.0000 | Calculated from schedules | 0.2057 | 1.0712 | 1.0000 | 1.0000 | Not calculated | 0.2057 | 0.1921 | ||
PSZ-AC_3:3 | 1.0696 | 0.0000 | 28.1245 | 1.0000 | Calculated from schedules | 0.2057 | 1.0696 | 1.0000 | 1.0000 | Not calculated | 0.2057 | 0.1923 | ||
PSZ-AC_4:4 | 1.0731 | 0.0000 | 28.1245 | 1.0000 | Calculated from schedules | 0.2057 | 1.0731 | 1.0000 | 1.0000 | Not calculated | 0.2057 | 0.1917 | ||
PSZ-AC_5:5 | 1.0688 | 0.0000 | 28.1245 | 1.0000 | Calculated from schedules | 0.2057 | 1.0688 | 1.0000 | 1.0000 | Not calculated | 0.2057 | 0.1925 | ||
PSZ-AC_6:6 | 1.9712 | 0.0000 | 56.2505 | 1.0000 | Calculated from schedules | 0.4115 | 1.9712 | 1.0000 | 1.0000 | Not calculated | 0.4115 | 0.2087 | ||
PSZ-AC_7:7 | 1.0198 | 0.0000 | 28.1245 | 1.0000 | Calculated from schedules | 0.2057 | 1.0198 | 1.0000 | 1.0000 | Not calculated | 0.2057 | 0.2017 | ||
PSZ-AC_8:8 | 1.0142 | 0.0000 | 28.1245 | 1.0000 | Calculated from schedules | 0.2057 | 1.0142 | 1.0000 | 1.0000 | Not calculated | 0.2057 | 0.2029 | ||
PSZ-AC_9:9 | 1.0138 | 0.0000 | 28.1245 | 1.0000 | Calculated from schedules | 0.2057 | 1.0138 | 1.0000 | 1.0000 | Not calculated | 0.2057 | 0.2029 | ||
PSZ-AC_10:10 | 1.2398 | 0.0000 | 28.1245 | 1.0000 | Calculated from schedules | 0.2057 | 1.2398 | 1.0000 | 1.0000 | Not calculated | 0.2057 | 0.1659 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
LGSTORE1 | PSZ-AC_1:1 | 0.000000 | 56.2505 | 0.001181 | 348.39 | 0.4115 | 1.0000 | 0.4115 | 1.000 | 0.4115 |
SMSTORE1 | PSZ-AC_2:2 | 0.000000 | 28.1245 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE2 | PSZ-AC_3:3 | 0.000000 | 28.1245 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE3 | PSZ-AC_4:4 | 0.000000 | 28.1245 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE4 | PSZ-AC_5:5 | 0.000000 | 28.1245 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
LGSTORE2 | PSZ-AC_6:6 | 0.000000 | 56.2505 | 0.001181 | 348.39 | 0.4115 | 1.0000 | 0.4115 | 1.000 | 0.4115 |
SMSTORE5 | PSZ-AC_7:7 | 0.000000 | 28.1245 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE6 | PSZ-AC_8:8 | 0.000000 | 28.1245 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE7 | PSZ-AC_9:9 | 0.000000 | 28.1245 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE8 | PSZ-AC_10:10 | 0.000000 | 28.1245 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC_1:1 | 0.000000 | 56.25 | 0.001181 | 348.3864 | 0.4115 | 0.4115 | 0.4115 |
PSZ-AC_2:2 | 0.000000 | 28.12 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_3:3 | 0.000000 | 28.12 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_4:4 | 0.000000 | 28.12 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_5:5 | 0.000000 | 28.12 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_6:6 | 0.000000 | 56.25 | 0.001181 | 348.3864 | 0.4115 | 0.4115 | 0.4115 |
PSZ-AC_7:7 | 0.000000 | 28.12 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_8:8 | 0.000000 | 28.12 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_9:9 | 0.000000 | 28.12 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_10:10 | 0.000000 | 28.12 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
LGSTORE1 | PSZ-AC_1:1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 2.0279 | 2.0279 | 2.0279 | No | 0.4115 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
SMSTORE1 | PSZ-AC_2:2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0712 | 1.0712 | 1.0712 | No | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
SMSTORE2 | PSZ-AC_3:3 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0696 | 1.0696 | 1.0696 | No | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
SMSTORE3 | PSZ-AC_4:4 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0731 | 1.0731 | 1.0731 | No | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
SMSTORE4 | PSZ-AC_5:5 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0688 | 1.0688 | 1.0688 | No | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
LGSTORE2 | PSZ-AC_6:6 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.9712 | 1.9712 | 1.9712 | No | 0.4115 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
SMSTORE5 | PSZ-AC_7:7 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0198 | 1.0198 | 1.0198 | No | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
SMSTORE6 | PSZ-AC_8:8 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0142 | 1.0142 | 1.0142 | No | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
SMSTORE7 | PSZ-AC_9:9 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0138 | 1.0138 | 1.0138 | No | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
SMSTORE8 | PSZ-AC_10:10 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.2398 | 1.2398 | 1.2398 | No | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC_1:1 | 2.0279 | 2.0279 | 2.0279 | 2.0279 | 0.4115 | 1.0000 |
PSZ-AC_2:2 | 1.0712 | 1.0712 | 1.0712 | 1.0712 | 0.2057 | 1.0000 |
PSZ-AC_3:3 | 1.0696 | 1.0696 | 1.0696 | 1.0696 | 0.2057 | 1.0000 |
PSZ-AC_4:4 | 1.0731 | 1.0731 | 1.0731 | 1.0731 | 0.2057 | 1.0000 |
PSZ-AC_5:5 | 1.0688 | 1.0688 | 1.0688 | 1.0688 | 0.2057 | 1.0000 |
PSZ-AC_6:6 | 1.9712 | 1.9712 | 1.9712 | 1.9712 | 0.4115 | 1.0000 |
PSZ-AC_7:7 | 1.0198 | 1.0225 | 1.0198 | 1.0198 | 0.2057 | 1.0000 |
PSZ-AC_8:8 | 1.0142 | 1.0172 | 1.0142 | 1.0142 | 0.2057 | 1.0000 |
PSZ-AC_9:9 | 1.0138 | 1.0138 | 1.0138 | 1.0138 | 0.2057 | 1.0000 |
PSZ-AC_10:10 | 1.2398 | 1.2398 | 1.2398 | 1.2398 | 0.2057 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
LGSTORE1 | PSZ-AC_1:1 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 2.0279 | 2.0279 | 2.0279 | No | 0.4115 | 0.2032 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
SMSTORE1 | PSZ-AC_2:2 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0712 | 1.0712 | 1.0712 | No | 0.2057 | 0.2133 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
SMSTORE2 | PSZ-AC_3:3 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0696 | 1.0696 | 1.0696 | No | 0.2057 | 0.2118 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
SMSTORE3 | PSZ-AC_4:4 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0731 | 1.0731 | 1.0731 | No | 0.2057 | 0.2111 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
SMSTORE4 | PSZ-AC_5:5 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0688 | 1.0688 | 1.0688 | No | 0.2057 | 0.2096 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
LGSTORE2 | PSZ-AC_6:6 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.9712 | 1.9712 | 1.9712 | No | 0.4115 | 0.2211 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
SMSTORE5 | PSZ-AC_7:7 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0198 | 1.0198 | 1.0198 | No | 0.2057 | 0.2057 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
SMSTORE6 | PSZ-AC_8:8 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0142 | 1.0142 | 1.0142 | No | 0.2057 | 0.2059 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
SMSTORE7 | PSZ-AC_9:9 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.0138 | 1.0138 | 1.0138 | No | 0.2057 | 0.2029 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
SMSTORE8 | PSZ-AC_10:10 | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.2398 | 1.2398 | 1.2398 | No | 0.2057 | 0.1659 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC_1:1 | 2.0279 | 2.0279 | 2.0279 | 2.0279 | 0.4115 | 1.0000 |
PSZ-AC_2:2 | 1.0712 | 1.0712 | 1.0712 | 1.0712 | 0.2057 | 1.0000 |
PSZ-AC_3:3 | 1.0696 | 1.0696 | 1.0696 | 1.0696 | 0.2057 | 1.0000 |
PSZ-AC_4:4 | 1.0731 | 1.0731 | 1.0731 | 1.0731 | 0.2057 | 1.0000 |
PSZ-AC_5:5 | 1.0688 | 1.0688 | 1.0688 | 1.0688 | 0.2057 | 1.0000 |
PSZ-AC_6:6 | 1.9712 | 1.9712 | 1.9712 | 1.9712 | 0.4115 | 1.0000 |
PSZ-AC_7:7 | 1.0198 | 1.0198 | 1.0198 | 1.0198 | 0.2057 | 1.0000 |
PSZ-AC_8:8 | 1.0142 | 1.0142 | 1.0142 | 1.0142 | 0.2057 | 1.0000 |
PSZ-AC_9:9 | 1.0138 | 1.0138 | 1.0138 | 1.0138 | 0.2057 | 1.0000 |
PSZ-AC_10:10 | 1.2398 | 1.2398 | 1.2398 | 1.2398 | 0.2057 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** International Falls Intl Ap MN USA TMY3 WMO#=727470 |
Total gross floor area [m2] | 2090.32 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
LGSTORE1 | 348.39 | 348.39 | 0.00 | 112.00 |
SMSTORE1 | 174.19 | 174.19 | 0.00 | 112.00 |
SMSTORE2 | 174.19 | 174.19 | 0.00 | 84.29 |
SMSTORE3 | 174.19 | 174.19 | 0.00 | 84.29 |
SMSTORE4 | 174.19 | 174.19 | 0.00 | 84.29 |
LGSTORE2 | 348.39 | 348.39 | 0.00 | 77.29 |
SMSTORE5 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE6 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE7 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE8 | 174.19 | 174.19 | 0.00 | 77.29 |
Totals | 2090.32 | 2090.32 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 0.17 |
Number of hours not met | 0.17 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- General | 0.00 | 0.00 | 946.15 | 371004.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- General | 56.78 | 44729.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 441.52 | 27522.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 100.02 | 7619.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 128.72 | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 109.86 | 11214.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- General | 9.17 | 690.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 67.48 | 13283.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 128.72 | 913.55 |
Natural Gas | 0.00 | 946.15 |
Additional | 0.00 | 0.00 |
Total | 128.72 | 1859.70 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 211.22 |
Space Heating | 0.00 |
Space Cooling | 27.16 |
Fans (All) | 52.56 |
Service Water Heating | 32.28 |
Receptacle Equipment | 61.58 |
Miscellaneous (All) | 437.04 |
Subtotal | 437.04 |
Natural Gas [MJ/m2] | |
Space Heating | 452.63 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 452.63 |
Subtotal | 452.63 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 23.74 |
Space Heating | 50.88 |
Space Cooling | 3.05 |
Fans (All) | 5.91 |
Service Water Heating | 3.63 |
Receptacle Equipment | 6.92 |
Miscellaneous | 5.87 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
TYPE1_OCC_SCH | 1630. | 5840. |
TYPE2_OCC_SCH | 995. | 4429. |
TYPE3_OCC_SCH | 1709. | 4064. |
LTG_SCH_DISPLAY_LPD_TYPE1_SMSTORE | 3767. | 8760. |
LTG_SCH_BASE_LPD2 | 3238. | 8760. |
LTG_SCH_BASE_SMALL_LPD2_TYPE3 | 3296. | 8760. |
LTG_SCH_DISPLAY_LPD_TYPE3_LGSTORE | 5084. | 8760. |
LTG_SCH_DISPLAY_LPD_TYPE3_SMSTORE | 5084. | 8760. |
LTG_SCH_BASE_SMALL_LPD1 | 4469. | 8760. |
LTG_SCH_BASE_LPD1 | 4391. | 8760. |
LTG_SCH_DISPLAY_LPD_TYPE1_LGSTORE | 3767. | 8760. |
LTG_SCH_BASE_SMALL_LPD2_TYPE2 | 3584. | 8760. |
LTG_SCH_DISPLAY_LPD_TYPE2_SMSTORE | 4096. | 8760. |
TYPE1_EQUIP_SCH | 4888. | 8760. |
TYPE2_EQUIP_SCH | 3911. | 8760. |
TYPE3_EQUIP_SCH | 3600. | 8760. |
TYPE1_INFIL_SCH | 4302. | 8760. |
TYPE2_INFIL_SCH | 5164. | 8760. |
TYPE3_INFIL_SCH | 5438. | 8760. |
INFIL_DOOR_OPENING_SCH | 2477. | 4380. |
TYPE1_MINOA_MOTORIZEDDAMPER_SCH | 5579. | 5579. |
TYPE2_MINOA_MOTORIZEDDAMPER_SCH | 4429. | 4429. |
TYPE3_MINOA_MOTORIZEDDAMPER_SCH | 4064. | 4064. |
TYPE1_SWH_SCH | 2063. | 6048. |
TYPE2_SWH_SCH | 1831. | 4429. |
TYPE3_SWH_SCH | 1733. | 4064. |
AVERAGE_SWH_SCH | 1863. | 6152. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 7118. | 8760. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 5839. | 5839. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 7300. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
TYPE1_HTGSETP_SCH_YES_OPTIMUM | LGSTORE1 DUAL SP CONTROL | January | 21.11 | 365 | 21.11 | 365 |
TYPE1_CLGSETP_SCH_YES_OPTIMUM | LGSTORE1 DUAL SP CONTROL | July | 23.89 | 365 | 23.89 | 365 |
TYPE2_HTGSETP_SCH_YES_OPTIMUM | SMSTORE2 DUAL SP CONTROL | January | 21.11 | 365 | 15.56 | 365 |
TYPE2_CLGSETP_SCH_YES_OPTIMUM | SMSTORE2 DUAL SP CONTROL | July | 23.89 | 365 | 29.44 | 365 |
TYPE3_HTGSETP_SCH_YES_OPTIMUM | LGSTORE2 DUAL SP CONTROL | January | 21.11 | 365 | 15.56 | 365 |
TYPE3_CLGSETP_SCH_YES_OPTIMUM | LGSTORE2 DUAL SP CONTROL | July | 23.89 | 365 | 29.44 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Heat Index HoursSafe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
LGSTORE1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE2 | 8740.83 | 19.17 | 0.00 | 0.00 | 0.00 |
SMSTORE3 | 8739.00 | 21.00 | 0.00 | 0.00 | 0.00 |
SMSTORE4 | 8743.17 | 16.83 | 0.00 | 0.00 | 0.00 |
LGSTORE2 | 8747.83 | 12.17 | 0.00 | 0.00 | 0.00 |
SMSTORE5 | 8748.67 | 11.33 | 0.00 | 0.00 | 0.00 |
SMSTORE6 | 8749.83 | 10.17 | 0.00 | 0.00 | 0.00 |
SMSTORE7 | 8751.33 | 8.67 | 0.00 | 0.00 | 0.00 |
SMSTORE8 | 8750.67 | 9.33 | 0.00 | 0.00 | 0.00 |
Min | 8739.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 8760.00 | 21.00 | 0.00 | 0.00 | 0.00 |
Average | 8749.13 | 10.87 | 0.00 | 0.00 | 0.00 |
Sum | 87491.33 | 108.67 | 0.00 | 0.00 | 0.00 |
Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
LGSTORE1 | 89041.00 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE1 | 43777.00 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE2 | 25471.33 | 3.67 | 0.00 | 0.00 | 0.00 |
SMSTORE3 | 25471.33 | 3.67 | 0.00 | 0.00 | 0.00 |
SMSTORE4 | 25471.67 | 3.33 | 0.00 | 0.00 | 0.00 |
LGSTORE2 | 93196.00 | 15.00 | 0.00 | 0.00 | 0.00 |
SMSTORE5 | 45904.00 | 8.00 | 0.00 | 0.00 | 0.00 |
SMSTORE6 | 45904.50 | 7.50 | 0.00 | 0.00 | 0.00 |
SMSTORE7 | 45905.00 | 7.00 | 0.00 | 0.00 | 0.00 |
SMSTORE8 | 45904.50 | 7.50 | 0.00 | 0.00 | 0.00 |
Min | 25471.33 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 93196.00 | 15.00 | 0.00 | 0.00 | 0.00 |
Average | 48604.63 | 5.57 | 0.00 | 0.00 | 0.00 |
Sum | 486046.33 | 55.67 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
LGSTORE1 | 8372.50 | 387.50 | 0.00 | 0.00 | 0.00 |
SMSTORE1 | 8577.83 | 182.17 | 0.00 | 0.00 | 0.00 |
SMSTORE2 | 8151.50 | 608.50 | 0.00 | 0.00 | 0.00 |
SMSTORE3 | 8153.00 | 607.00 | 0.00 | 0.00 | 0.00 |
SMSTORE4 | 8161.83 | 598.17 | 0.00 | 0.00 | 0.00 |
LGSTORE2 | 8245.00 | 515.00 | 0.00 | 0.00 | 0.00 |
SMSTORE5 | 8184.17 | 575.83 | 0.00 | 0.00 | 0.00 |
SMSTORE6 | 8194.67 | 565.33 | 0.00 | 0.00 | 0.00 |
SMSTORE7 | 8239.33 | 520.67 | 0.00 | 0.00 | 0.00 |
SMSTORE8 | 8297.67 | 462.33 | 0.00 | 0.00 | 0.00 |
Min | 8151.50 | 182.17 | 0.00 | 0.00 | 0.00 |
Max | 8577.83 | 608.50 | 0.00 | 0.00 | 0.00 |
Average | 8257.75 | 502.25 | 0.00 | 0.00 | 0.00 |
Sum | 82577.50 | 5022.50 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
LGSTORE1 | 87278.83 | 1762.17 | 0.00 | 0.00 | 0.00 |
SMSTORE1 | 43106.50 | 670.50 | 0.00 | 0.00 | 0.00 |
SMSTORE2 | 24869.33 | 605.67 | 0.00 | 0.00 | 0.00 |
SMSTORE3 | 24865.83 | 609.17 | 0.00 | 0.00 | 0.00 |
SMSTORE4 | 24840.00 | 635.00 | 0.00 | 0.00 | 0.00 |
LGSTORE2 | 90998.33 | 2212.67 | 0.00 | 0.00 | 0.00 |
SMSTORE5 | 44553.17 | 1358.83 | 0.00 | 0.00 | 0.00 |
SMSTORE6 | 44527.83 | 1384.17 | 0.00 | 0.00 | 0.00 |
SMSTORE7 | 44479.67 | 1432.33 | 0.00 | 0.00 | 0.00 |
SMSTORE8 | 44272.17 | 1639.83 | 0.00 | 0.00 | 0.00 |
Min | 24840.00 | 605.67 | 0.00 | 0.00 | 0.00 |
Max | 90998.33 | 2212.67 | 0.00 | 0.00 | 0.00 |
Average | 47379.17 | 1231.03 | 0.00 | 0.00 | 0.00 |
Sum | 473791.67 | 12310.33 | 0.00 | 0.00 | 0.00 |
SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
None |
SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
CO2 Level HoursSafe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:41:09
Illuminance Level HoursA Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
None |
A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
None |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTRIPMALL
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 7
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MN_INTERNATIONALFALLS
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -16.89 |
February | -11.56 |
March | -6.15 |
April | 3.968 |
May | 13.433 |
June | 18.029 |
July | 19.667 |
August | 17.942 |
September | 12.293 |
October | 5.424 |
November | -2.00 |
December | -14.64 |
Annual Sum or Average | 3.363 |
Minimum of Months | -16.89 |
Maximum of Months | 19.667 |
Report: ZoneCoolingSummaryMonthly
For: LGSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.231467E+09 | 23872.43 | 06-JAN-00:01 | -32.3 | -32.4 | 0.106203E+10 | 1275.40 | 22-JAN-18:00 | -15.6 | -16.1 |
February | 0.305300E+09 | 20041.32 | 25-FEB-00:01 | -24.1 | -24.4 | 0.959170E+09 | 1304.67 | 20-FEB-18:30 | -24.1 | -24.4 |
March | 0.528273E+09 | 5982.68 | 15-MAR-08:04 | -22.3 | -22.6 | 0.106562E+10 | 1563.61 | 26-MAR-17:00 | 8.90 | 4.40 |
April | 0.198073E+10 | 8760.87 | 23-APR-16:03 | 26.60 | 16.90 | 0.115535E+10 | 1685.95 | 23-APR-17:00 | 25.60 | 16.47 |
May | 0.693784E+10 | 32018.87 | 26-MAY-08:62 | 20.60 | 16.95 | 0.138134E+10 | 1685.90 | 28-MAY-12:00 | 21.30 | 13.54 |
June | 0.102065E+11 | 31644.43 | 26-JUN-08:62 | 18.58 | 16.33 | 0.135437E+10 | 1686.00 | 25-JUN-12:50 | 18.58 | 16.33 |
July | 0.134057E+11 | 36316.80 | 01-JUL-08:62 | 17.57 | 14.63 | 0.141342E+10 | 1686.01 | 23-JUL-12:00 | 30.00 | 22.84 |
August | 0.121641E+11 | 34222.60 | 10-AUG-08:62 | 15.87 | 15.41 | 0.139431E+10 | 1686.00 | 27-AUG-17:10 | 22.80 | 19.07 |
September | 0.743894E+10 | 30497.98 | 01-SEP-08:62 | 18.17 | 16.90 | 0.135257E+10 | 1686.00 | 03-SEP-17:10 | 21.52 | 16.01 |
October | 0.307165E+10 | 8396.72 | 22-OCT-17:03 | 16.13 | 10.55 | 0.122951E+10 | 1685.90 | 22-OCT-12:00 | 16.13 | 10.55 |
November | 0.725477E+09 | 5386.56 | 25-NOV-09:04 | -17.6 | -18.0 | 0.104257E+10 | 1404.85 | 01-NOV-17:00 | -17.6 | -18.0 |
December | 0.165999E+09 | 18029.06 | 02-DEC-00:33 | -23.9 | -24.2 | 0.106786E+10 | 1275.40 | 10-DEC-17:10 | -23.8 | -24.3 |
Annual Sum or Average | 0.571620E+11 | 0.144781E+11 | ||||||||
Minimum of Months | 0.165999E+09 | 5386.56 | -32.3 | -32.4 | 0.959170E+09 | 1275.40 | -24.1 | -24.4 | ||
Maximum of Months | 0.134057E+11 | 36316.80 | 26.60 | 16.95 | 0.141342E+10 | 1686.01 | 30.00 | 22.84 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 33660280.68 | 9753.03 | 27-JAN-20:31 | -23.1 | -23.3 | 0.532618E+09 | 675.04 | 29-JAN-18:00 | -3.3 | -4.1 |
February | 0.151624E+09 | 9047.36 | 10-FEB-09:04 | -20.3 | -20.7 | 0.483997E+09 | 726.99 | 20-FEB-18:00 | 4.40 | 1.28 |
March | 0.480674E+09 | 8721.11 | 18-MAR-08:04 | -16.5 | -17.0 | 0.538260E+09 | 824.59 | 26-MAR-17:00 | 8.90 | 4.40 |
April | 0.177676E+10 | 12875.25 | 23-APR-20:40 | 20.17 | 13.63 | 0.573456E+09 | 842.95 | 23-APR-12:00 | 20.17 | 13.63 |
May | 0.464952E+10 | 17405.30 | 26-MAY-08:62 | 20.60 | 16.95 | 0.676131E+09 | 842.98 | 26-MAY-12:39 | 24.20 | 18.80 |
June | 0.597446E+10 | 22196.06 | 07-JUN-08:62 | 20.18 | 11.27 | 0.673909E+09 | 842.97 | 24-JUN-12:30 | 25.00 | 21.64 |
July | 0.743894E+10 | 19557.49 | 01-JUL-08:62 | 17.57 | 14.63 | 0.705068E+09 | 842.99 | 22-JUL-12:30 | 29.15 | 21.94 |
August | 0.684097E+10 | 18893.53 | 10-AUG-08:62 | 15.87 | 15.41 | 0.694764E+09 | 842.98 | 27-AUG-17:10 | 22.80 | 19.07 |
September | 0.481613E+10 | 17559.42 | 02-SEP-08:62 | 15.37 | 12.66 | 0.660545E+09 | 842.98 | 03-SEP-17:10 | 21.52 | 16.01 |
October | 0.253482E+10 | 12903.27 | 22-OCT-17:35 | 14.43 | 9.95 | 0.598406E+09 | 842.94 | 22-OCT-12:00 | 14.43 | 9.95 |
November | 0.595532E+09 | 8152.74 | 29-NOV-09:04 | -13.8 | -14.3 | 0.530011E+09 | 740.19 | 19-NOV-18:40 | -13.8 | -14.3 |
December | 47317903.05 | 8791.37 | 08-DEC-20:31 | -19.0 | -19.3 | 0.535555E+09 | 667.40 | 31-DEC-18:00 | -5.6 | -5.9 |
Annual Sum or Average | 0.353404E+11 | 0.720272E+10 | ||||||||
Minimum of Months | 33660280.68 | 8152.74 | -23.1 | -23.3 | 0.483997E+09 | 667.40 | -13.8 | -14.3 | ||
Maximum of Months | 0.743894E+10 | 22196.06 | 20.60 | 16.95 | 0.705068E+09 | 842.99 | 29.15 | 21.94 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 8891120.66 | 8030.91 | 18-JAN-08:04 | -13.8 | -14.0 | 0.316907E+09 | 637.68 | 14-JAN-13:50 | -13.8 | -14.0 |
February | 60382099.78 | 8454.17 | 11-FEB-08:04 | -15.5 | -15.9 | 0.287849E+09 | 637.68 | 11-FEB-13:20 | -6.5 | -8.2 |
March | 0.245551E+09 | 8953.48 | 23-MAR-07:04 | -17.6 | -17.9 | 0.325405E+09 | 637.68 | 04-MAR-13:09 | -17.6 | -17.9 |
April | 0.125253E+10 | 7521.45 | 05-APR-07:04 | -11.2 | -12.1 | 0.329388E+09 | 805.30 | 22-APR-12:00 | 16.10 | 6.66 |
May | 0.328844E+10 | 18026.09 | 26-MAY-07:02 | 20.08 | 16.35 | 0.399314E+09 | 842.92 | 27-MAY-12:00 | 21.90 | 13.70 |
June | 0.427442E+10 | 17584.38 | 22-JUN-07:02 | 18.27 | 16.37 | 0.412877E+09 | 842.97 | 24-JUN-12:39 | 25.20 | 21.78 |
July | 0.533738E+10 | 21090.73 | 17-JUL-07:02 | 14.50 | 12.49 | 0.419317E+09 | 843.00 | 22-JUL-12:30 | 29.15 | 21.94 |
August | 0.498176E+10 | 20527.59 | 07-AUG-07:02 | 13.98 | 13.37 | 0.429738E+09 | 842.96 | 05-AUG-12:30 | 13.98 | 13.37 |
September | 0.346521E+10 | 22051.80 | 02-SEP-07:02 | 13.17 | 11.14 | 0.385280E+09 | 842.96 | 02-SEP-12:50 | 19.90 | 14.39 |
October | 0.175013E+10 | 6046.26 | 30-OCT-07:04 | -9.0 | -9.4 | 0.336842E+09 | 842.90 | 21-OCT-12:50 | -9.0 | -9.4 |
November | 0.358675E+09 | 7228.59 | 23-NOV-09:04 | -10.0 | -10.5 | 0.307618E+09 | 637.68 | 18-NOV-13:09 | -10.0 | -10.5 |
December | 11943768.76 | 7874.56 | 15-DEC-08:04 | -13.1 | -13.6 | 0.316527E+09 | 637.68 | 02-DEC-13:09 | -13.1 | -13.6 |
Annual Sum or Average | 0.250353E+11 | 0.426706E+10 | ||||||||
Minimum of Months | 8891120.66 | 6046.26 | -17.6 | -17.9 | 0.287849E+09 | 637.68 | -17.6 | -17.9 | ||
Maximum of Months | 0.533738E+10 | 22051.80 | 20.08 | 16.37 | 0.429738E+09 | 843.00 | 29.15 | 21.94 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 6869092.49 | 9347.97 | 07-JAN-08:04 | -21.0 | -21.3 | 0.316907E+09 | 637.68 | 07-JAN-13:09 | -17.8 | -18.3 |
February | 46310910.96 | 8435.17 | 11-FEB-08:04 | -15.5 | -15.9 | 0.287844E+09 | 637.68 | 11-FEB-13:00 | -6.1 | -8.0 |
March | 0.212829E+09 | 8934.84 | 23-MAR-07:04 | -17.6 | -17.9 | 0.325384E+09 | 637.68 | 11-MAR-13:09 | -17.6 | -17.9 |
April | 0.114067E+10 | 7578.92 | 05-APR-07:04 | -11.2 | -12.1 | 0.328107E+09 | 795.76 | 22-APR-12:00 | 16.10 | 6.66 |
May | 0.318467E+10 | 18109.85 | 26-MAY-07:02 | 20.08 | 16.35 | 0.397709E+09 | 842.92 | 27-MAY-12:00 | 21.90 | 13.70 |
June | 0.422029E+10 | 17637.66 | 22-JUN-07:02 | 18.27 | 16.37 | 0.412444E+09 | 842.97 | 24-JUN-12:50 | 25.40 | 21.91 |
July | 0.534029E+10 | 21177.63 | 17-JUL-07:02 | 14.50 | 12.49 | 0.419287E+09 | 842.99 | 22-JUL-12:30 | 29.15 | 21.94 |
August | 0.496331E+10 | 20599.78 | 07-AUG-07:02 | 13.98 | 13.37 | 0.429613E+09 | 842.96 | 05-AUG-12:30 | 13.98 | 13.37 |
September | 0.337728E+10 | 22129.55 | 02-SEP-07:02 | 13.17 | 11.14 | 0.383879E+09 | 842.96 | 02-SEP-12:50 | 19.90 | 14.39 |
October | 0.160616E+10 | 6857.71 | 30-OCT-07:04 | -9.0 | -9.4 | 0.335613E+09 | 842.90 | 21-OCT-12:50 | -9.0 | -9.4 |
November | 0.302150E+09 | 7264.06 | 23-NOV-09:04 | -10.0 | -10.5 | 0.307441E+09 | 637.68 | 18-NOV-13:09 | -10.0 | -10.5 |
December | 9791195.26 | 7867.48 | 15-DEC-08:04 | -13.1 | -13.6 | 0.316525E+09 | 637.68 | 02-DEC-13:30 | -13.1 | -13.6 |
Annual Sum or Average | 0.244106E+11 | 0.426075E+10 | ||||||||
Minimum of Months | 6869092.49 | 6857.71 | -21.0 | -21.3 | 0.287844E+09 | 637.68 | -17.8 | -18.3 | ||
Maximum of Months | 0.534029E+10 | 22129.55 | 20.08 | 16.37 | 0.429613E+09 | 842.99 | 29.15 | 21.94 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 5359133.21 | 7246.29 | 22-JAN-09:04 | -11.9 | -12.6 | 0.316907E+09 | 637.68 | 07-JAN-13:39 | -11.9 | -12.6 |
February | 35216772.95 | 7818.86 | 28-FEB-08:04 | -13.8 | -14.3 | 0.287858E+09 | 637.68 | 04-FEB-13:00 | -13.8 | -14.3 |
March | 0.165475E+09 | 7749.79 | 11-MAR-08:04 | -12.3 | -12.5 | 0.325364E+09 | 637.68 | 04-MAR-13:30 | -12.3 | -12.5 |
April | 0.106127E+10 | 7524.29 | 05-APR-07:04 | -11.2 | -12.1 | 0.327562E+09 | 795.88 | 22-APR-12:00 | 16.10 | 6.66 |
May | 0.308536E+10 | 17894.39 | 26-MAY-07:02 | 20.08 | 16.35 | 0.397137E+09 | 842.92 | 27-MAY-12:00 | 21.90 | 13.70 |
June | 0.409331E+10 | 17434.88 | 22-JUN-07:02 | 18.27 | 16.37 | 0.412160E+09 | 842.97 | 24-JUN-12:00 | 25.60 | 22.05 |
July | 0.520617E+10 | 20990.83 | 17-JUL-07:02 | 14.50 | 12.49 | 0.419114E+09 | 843.00 | 22-JUL-12:39 | 29.23 | 22.07 |
August | 0.482755E+10 | 20419.90 | 07-AUG-07:02 | 13.98 | 13.37 | 0.429433E+09 | 842.96 | 26-AUG-12:09 | 25.10 | 19.13 |
September | 0.332379E+10 | 21931.39 | 02-SEP-07:02 | 13.17 | 11.14 | 0.383741E+09 | 842.96 | 02-SEP-12:50 | 19.90 | 14.39 |
October | 0.154563E+10 | 6931.00 | 30-OCT-07:04 | -9.0 | -9.4 | 0.335568E+09 | 842.90 | 21-OCT-12:00 | -9.0 | -9.4 |
November | 0.246436E+09 | 7269.24 | 23-NOV-09:04 | -10.0 | -10.5 | 0.307286E+09 | 637.68 | 18-NOV-13:09 | -10.0 | -10.5 |
December | 7389791.31 | 6773.24 | 07-DEC-08:04 | -7.8 | -8.0 | 0.316525E+09 | 637.68 | 02-DEC-13:30 | -7.8 | -8.0 |
Annual Sum or Average | 0.236030E+11 | 0.425865E+10 | ||||||||
Minimum of Months | 5359133.21 | 6773.24 | -13.8 | -14.3 | 0.287858E+09 | 637.68 | -13.8 | -14.3 | ||
Maximum of Months | 0.520617E+10 | 21931.39 | 20.08 | 16.37 | 0.429433E+09 | 843.00 | 29.23 | 22.07 |
Report: ZoneCoolingSummaryMonthly
For: LGSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 14147861.46 | 6012.33 | 08-JAN-10:04 | -22.8 | -23.0 | 0.108321E+10 | 1700.53 | 07-JAN-15:39 | -22.8 | -23.0 |
February | 33460075.73 | 6172.67 | 24-FEB-09:04 | -22.5 | -23.0 | 0.986207E+09 | 1700.53 | 11-FEB-15:39 | -22.5 | -23.0 |
March | 0.176037E+09 | 6064.78 | 15-MAR-08:04 | -22.3 | -22.6 | 0.111919E+10 | 1700.53 | 04-MAR-15:09 | -22.3 | -22.6 |
April | 0.931575E+09 | 6644.79 | 23-APR-15:00 | 25.60 | 16.48 | 0.117427E+10 | 2247.74 | 22-APR-14:09 | 25.60 | 16.48 |
May | 0.422662E+10 | 31961.92 | 26-MAY-08:62 | 20.60 | 16.95 | 0.142264E+10 | 2247.87 | 27-MAY-14:00 | 22.20 | 14.09 |
June | 0.701152E+10 | 32231.74 | 18-JUN-09:02 | 21.97 | 14.91 | 0.142884E+10 | 2247.90 | 24-JUN-14:09 | 27.88 | 23.16 |
July | 0.920581E+10 | 36101.77 | 01-JUL-08:62 | 17.57 | 14.63 | 0.143852E+10 | 2247.91 | 22-JUL-14:00 | 30.00 | 22.47 |
August | 0.840699E+10 | 34183.84 | 10-AUG-08:62 | 15.87 | 15.41 | 0.147980E+10 | 2248.01 | 12-AUG-14:39 | 21.70 | 16.10 |
September | 0.450771E+10 | 30914.11 | 02-SEP-08:62 | 15.37 | 12.66 | 0.138408E+10 | 2247.90 | 02-SEP-14:00 | 17.80 | 14.76 |
October | 0.144511E+10 | 7316.53 | 22-OCT-14:10 | 19.40 | 12.77 | 0.121272E+10 | 2247.80 | 21-OCT-14:09 | 19.40 | 12.77 |
November | 0.207856E+09 | 5428.49 | 25-NOV-09:04 | -17.6 | -18.0 | 0.105318E+10 | 1874.58 | 01-NOV-16:40 | -17.6 | -18.0 |
December | 16133575.26 | 6042.04 | 01-DEC-09:04 | -21.5 | -21.7 | 0.108504E+10 | 1700.53 | 02-DEC-15:39 | -18.1 | -18.8 |
Annual Sum or Average | 0.361830E+11 | 0.148677E+11 | ||||||||
Minimum of Months | 14147861.46 | 5428.49 | -22.8 | -23.0 | 0.986207E+09 | 1700.53 | -22.8 | -23.0 | ||
Maximum of Months | 0.920581E+10 | 36101.77 | 25.60 | 16.95 | 0.147980E+10 | 2248.01 | 30.00 | 23.16 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 3949646.99 | 6821.76 | 20-JAN-09:04 | -8.3 | -8.9 | 0.541588E+09 | 850.24 | 07-JAN-15:00 | -8.3 | -8.9 |
February | 14816120.45 | 7144.07 | 28-FEB-09:04 | -9.9 | -10.9 | 0.493094E+09 | 850.24 | 04-FEB-15:39 | -9.9 | -10.9 |
March | 0.106710E+09 | 7579.16 | 23-MAR-08:04 | -13.2 | -13.3 | 0.558590E+09 | 850.24 | 11-MAR-15:00 | -13.2 | -13.3 |
April | 0.857365E+09 | 6892.46 | 05-APR-08:04 | -8.5 | -10.3 | 0.559477E+09 | 1123.84 | 22-APR-14:00 | 18.30 | 7.82 |
May | 0.269553E+10 | 16353.64 | 26-MAY-08:62 | 20.60 | 16.95 | 0.675930E+09 | 1123.90 | 27-MAY-14:00 | 22.20 | 14.09 |
June | 0.369638E+10 | 16053.76 | 26-JUN-08:62 | 18.58 | 16.33 | 0.705446E+09 | 1123.97 | 24-JUN-14:39 | 18.58 | 16.33 |
July | 0.478095E+10 | 18467.40 | 06-JUL-08:62 | 17.88 | 14.74 | 0.717387E+09 | 1123.87 | 29-JUL-14:09 | 29.50 | 21.35 |
August | 0.439723E+10 | 17432.27 | 10-AUG-08:62 | 15.87 | 15.41 | 0.735849E+09 | 1123.97 | 12-AUG-14:39 | 21.70 | 16.10 |
September | 0.290864E+10 | 15422.04 | 01-SEP-08:62 | 18.17 | 16.90 | 0.655929E+09 | 1123.91 | 02-SEP-14:00 | 17.80 | 14.76 |
October | 0.127963E+10 | 6420.11 | 30-OCT-08:04 | -6.1 | -6.7 | 0.571680E+09 | 1123.87 | 21-OCT-14:09 | -6.1 | -6.7 |
November | 0.154310E+09 | 7255.93 | 23-NOV-10:04 | -10.0 | -10.6 | 0.523263E+09 | 858.68 | 01-NOV-16:30 | -10.0 | -10.6 |
December | 6359853.79 | 6727.70 | 07-DEC-09:04 | -7.8 | -7.9 | 0.542506E+09 | 850.24 | 02-DEC-15:39 | -7.8 | -7.9 |
Annual Sum or Average | 0.209019E+11 | 0.728074E+10 | ||||||||
Minimum of Months | 3949646.99 | 6420.11 | -13.2 | -13.3 | 0.493094E+09 | 850.24 | -13.2 | -13.3 | ||
Maximum of Months | 0.478095E+10 | 18467.40 | 20.60 | 16.95 | 0.735849E+09 | 1123.97 | 29.50 | 21.35 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 3687625.13 | 6818.03 | 20-JAN-09:04 | -8.3 | -8.9 | 0.541588E+09 | 850.24 | 14-JAN-15:20 | -8.3 | -8.9 |
February | 13415415.05 | 7131.25 | 28-FEB-09:04 | -9.9 | -10.9 | 0.493094E+09 | 850.24 | 18-FEB-15:09 | -9.9 | -10.9 |
March | 93463705.73 | 7265.62 | 17-MAR-08:04 | -10.4 | -11.2 | 0.558586E+09 | 850.24 | 04-MAR-15:09 | -10.4 | -11.2 |
April | 0.752314E+09 | 6878.57 | 05-APR-08:04 | -8.5 | -10.3 | 0.556842E+09 | 1122.46 | 22-APR-14:00 | 18.30 | 7.82 |
May | 0.253408E+10 | 16184.52 | 26-MAY-08:62 | 20.60 | 16.95 | 0.670742E+09 | 1123.90 | 27-MAY-14:00 | 22.20 | 14.09 |
June | 0.356915E+10 | 15906.39 | 26-JUN-08:62 | 18.58 | 16.33 | 0.703229E+09 | 1123.96 | 24-JUN-14:39 | 18.58 | 16.33 |
July | 0.469566E+10 | 18314.12 | 06-JUL-08:62 | 17.88 | 14.74 | 0.717041E+09 | 1123.87 | 29-JUL-14:09 | 29.50 | 21.35 |
August | 0.430413E+10 | 17294.51 | 10-AUG-08:62 | 15.87 | 15.41 | 0.735103E+09 | 1123.97 | 12-AUG-14:50 | 21.70 | 15.95 |
September | 0.273639E+10 | 15295.65 | 01-SEP-08:62 | 18.17 | 16.90 | 0.651388E+09 | 1123.91 | 02-SEP-14:00 | 17.80 | 14.76 |
October | 0.113133E+10 | 6419.41 | 30-OCT-08:04 | -6.1 | -6.7 | 0.569079E+09 | 1123.87 | 21-OCT-14:09 | -6.1 | -6.7 |
November | 0.136324E+09 | 7235.30 | 23-NOV-10:04 | -10.0 | -10.6 | 0.523098E+09 | 850.46 | 01-NOV-16:30 | -10.0 | -10.6 |
December | 5846433.66 | 6716.33 | 07-DEC-09:04 | -7.8 | -7.9 | 0.542506E+09 | 850.24 | 02-DEC-15:20 | -7.8 | -7.9 |
Annual Sum or Average | 0.199758E+11 | 0.726230E+10 | ||||||||
Minimum of Months | 3687625.13 | 6419.41 | -10.4 | -11.2 | 0.493094E+09 | 850.24 | -10.4 | -11.2 | ||
Maximum of Months | 0.469566E+10 | 18314.12 | 20.60 | 16.95 | 0.735103E+09 | 1123.97 | 29.50 | 21.35 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 2837118.49 | 6767.54 | 20-JAN-09:04 | -8.3 | -8.9 | 0.541588E+09 | 850.24 | 07-JAN-15:20 | -8.3 | -8.9 |
February | 8439355.19 | 6709.25 | 23-FEB-09:04 | -7.7 | -8.7 | 0.493094E+09 | 850.24 | 04-FEB-15:30 | -7.7 | -8.7 |
March | 57458770.70 | 7025.90 | 11-MAR-09:04 | -9.4 | -9.9 | 0.558577E+09 | 850.24 | 04-MAR-15:50 | -9.4 | -9.9 |
April | 0.579545E+09 | 6827.05 | 05-APR-08:04 | -8.5 | -10.3 | 0.553053E+09 | 1095.28 | 22-APR-14:00 | 18.30 | 7.82 |
May | 0.224631E+10 | 15852.95 | 26-MAY-08:62 | 20.60 | 16.95 | 0.663559E+09 | 1123.90 | 27-MAY-14:00 | 22.20 | 14.09 |
June | 0.333058E+10 | 15598.95 | 26-JUN-08:62 | 18.58 | 16.33 | 0.699366E+09 | 1123.93 | 24-JUN-14:39 | 18.58 | 16.33 |
July | 0.451268E+10 | 18072.60 | 01-JUL-08:62 | 17.57 | 14.63 | 0.716230E+09 | 1123.89 | 29-JUL-14:09 | 29.50 | 21.35 |
August | 0.409758E+10 | 17047.68 | 10-AUG-08:62 | 15.87 | 15.41 | 0.733707E+09 | 1123.96 | 12-AUG-14:00 | 21.70 | 15.80 |
September | 0.248901E+10 | 15052.87 | 01-SEP-08:62 | 18.17 | 16.90 | 0.646021E+09 | 1123.90 | 02-SEP-14:00 | 17.80 | 14.76 |
October | 0.931308E+09 | 6341.93 | 30-OCT-08:04 | -6.1 | -6.7 | 0.566663E+09 | 1123.87 | 21-OCT-14:09 | -6.1 | -6.7 |
November | 92903328.65 | 7180.92 | 23-NOV-10:04 | -10.0 | -10.6 | 0.522745E+09 | 850.24 | 25-NOV-15:30 | -13.9 | -14.7 |
December | 4052280.04 | 6683.00 | 07-DEC-09:04 | -7.8 | -7.9 | 0.542506E+09 | 850.24 | 02-DEC-15:09 | -7.8 | -7.9 |
Annual Sum or Average | 0.183527E+11 | 0.723711E+10 | ||||||||
Minimum of Months | 2837118.49 | 6341.93 | -10.0 | -10.6 | 0.493094E+09 | 850.24 | -13.9 | -14.7 | ||
Maximum of Months | 0.451268E+10 | 18072.60 | 20.60 | 16.95 | 0.733707E+09 | 1123.96 | 29.50 | 21.35 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE8
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 2885458.27 | 6660.85 | 20-JAN-09:04 | -8.3 | -8.9 | 0.541588E+09 | 850.24 | 07-JAN-15:30 | -8.3 | -8.9 |
February | 5346785.08 | 6997.72 | 28-FEB-09:04 | -9.9 | -10.9 | 0.493094E+09 | 850.24 | 04-FEB-15:20 | -9.9 | -10.9 |
March | 10849111.45 | 7133.00 | 17-MAR-08:04 | -10.4 | -11.2 | 0.558576E+09 | 850.24 | 04-MAR-15:39 | -10.4 | -11.2 |
April | 0.285753E+09 | 6739.57 | 05-APR-08:04 | -8.5 | -10.3 | 0.548037E+09 | 1053.80 | 22-APR-14:00 | 18.30 | 7.82 |
May | 0.171612E+10 | 6646.10 | 26-MAY-08:62 | 20.60 | 16.95 | 0.652208E+09 | 1123.90 | 27-MAY-14:00 | 22.20 | 14.09 |
June | 0.312502E+10 | 16879.96 | 27-JUN-08:62 | 23.17 | 18.54 | 0.692014E+09 | 1123.97 | 24-JUN-14:39 | 23.17 | 18.54 |
July | 0.453296E+10 | 17711.41 | 24-JUL-08:61 | 23.07 | 18.74 | 0.713913E+09 | 1123.89 | 22-JUL-14:09 | 23.07 | 18.74 |
August | 0.391940E+10 | 16238.67 | 09-AUG-08:62 | 21.28 | 18.94 | 0.729737E+09 | 1123.95 | 26-AUG-14:00 | 26.10 | 19.38 |
September | 0.203447E+10 | 11929.73 | 01-SEP-08:62 | 18.17 | 16.90 | 0.637829E+09 | 1123.87 | 30-SEP-14:00 | 21.10 | 13.68 |
October | 0.527942E+09 | 6200.06 | 30-OCT-08:04 | -6.1 | -6.7 | 0.564154E+09 | 1123.87 | 21-OCT-14:00 | -6.1 | -6.7 |
November | 27783948.63 | 7070.79 | 23-NOV-10:04 | -10.0 | -10.6 | 0.522242E+09 | 850.24 | 04-NOV-14:50 | -10.0 | -10.6 |
December | 3757872.09 | 6580.58 | 07-DEC-09:04 | -7.8 | -7.9 | 0.542506E+09 | 850.24 | 09-DEC-15:30 | -17.6 | -18.7 |
Annual Sum or Average | 0.161923E+11 | 0.719590E+10 | ||||||||
Minimum of Months | 2885458.27 | 6200.06 | -10.4 | -11.2 | 0.493094E+09 | 850.24 | -17.6 | -18.7 | ||
Maximum of Months | 0.453296E+10 | 17711.41 | 23.17 | 18.94 | 0.729737E+09 | 1123.97 | 26.10 | 19.38 |
Report: ZoneHeatingSummaryMonthly
For: LGSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.173087E+11 | 70374.64 | 05-JAN-00:42 | -31.0 |
February | 0.103772E+11 | 69882.64 | 16-FEB-08:61 | -15.7 |
March | 0.764783E+10 | 69852.91 | 14-MAR-07:01 | -15.5 |
April | 0.179392E+10 | 69312.77 | 05-APR-07:01 | -11.2 |
May | 0.100649E+09 | 66816.38 | 01-MAY-08:61 | 1.73 |
June | 81230753.97 | 2188.32 | 30-JUN-08:06 | 25.97 |
July | 82072611.58 | 1502.04 | 30-JUL-07:05 | 21.65 |
August | 79453555.51 | 1129.65 | 09-AUG-08:05 | 21.28 |
September | 78073361.65 | 950.26 | 03-SEP-07:07 | 14.50 |
October | 0.659906E+09 | 66708.83 | 14-OCT-08:61 | 1.47 |
November | 0.480271E+10 | 69607.74 | 25-NOV-08:61 | -18.2 |
December | 0.157847E+11 | 69957.97 | 21-DEC-08:61 | -28.4 |
Annual Sum or Average | 0.587964E+11 | |||
Minimum of Months | 78073361.65 | 950.26 | -31.0 | |
Maximum of Months | 0.173087E+11 | 70374.64 | 25.97 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.630185E+10 | 36216.98 | 13-JAN-08:61 | -31.5 |
February | 0.347401E+10 | 36182.10 | 24-FEB-08:61 | -23.7 |
March | 0.242337E+10 | 36106.60 | 14-MAR-07:01 | -15.5 |
April | 0.464548E+09 | 31882.84 | 10-APR-08:61 | 2.25 |
May | 46827551.23 | 14179.01 | 01-MAY-08:61 | 1.73 |
June | 42098466.91 | 1158.67 | 30-JUN-08:06 | 25.97 |
July | 39978828.07 | 900.16 | 16-JUL-07:05 | 17.38 |
August | 42748756.19 | 760.84 | 27-AUG-07:07 | 12.88 |
September | 41782928.18 | 704.44 | 03-SEP-07:07 | 14.50 |
October | 0.187707E+09 | 29969.94 | 30-OCT-08:61 | -6.1 |
November | 0.154336E+10 | 33705.13 | 25-NOV-08:61 | -18.2 |
December | 0.578801E+10 | 36217.38 | 21-DEC-08:61 | -28.4 |
Annual Sum or Average | 0.203963E+11 | |||
Minimum of Months | 39978828.07 | 704.44 | -31.5 | |
Maximum of Months | 0.630185E+10 | 36217.38 | 25.97 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.701446E+10 | 36038.93 | 01-JAN-08:61 | -26.7 |
February | 0.406845E+10 | 36031.58 | 19-FEB-08:61 | -23.5 |
March | 0.291636E+10 | 35983.37 | 06-MAR-07:01 | -19.3 |
April | 0.665659E+09 | 31878.05 | 09-APR-08:61 | 1.70 |
May | 56095423.42 | 21987.30 | 01-MAY-07:02 | -0.9 |
June | 53519627.23 | 1797.17 | 29-JUN-19:03 | 30.73 |
July | 60281786.98 | 1543.23 | 23-JUL-16:02 | 29.72 |
August | 46583135.09 | 743.56 | 08-AUG-19:03 | 26.42 |
September | 43785322.71 | 452.19 | 27-SEP-07:00 | 6.70 |
October | 0.349022E+09 | 29418.45 | 30-OCT-07:01 | -9.0 |
November | 0.205512E+10 | 32225.55 | 26-NOV-08:61 | -9.3 |
December | 0.646256E+10 | 36141.75 | 19-DEC-07:01 | -25.8 |
Annual Sum or Average | 0.237919E+11 | |||
Minimum of Months | 43785322.71 | 452.19 | -26.7 | |
Maximum of Months | 0.701446E+10 | 36141.75 | 30.73 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.731371E+10 | 36119.60 | 08-JAN-08:61 | -22.9 |
February | 0.427053E+10 | 36104.14 | 19-FEB-08:61 | -23.5 |
March | 0.309663E+10 | 36056.54 | 06-MAR-07:01 | -19.3 |
April | 0.740347E+09 | 32007.49 | 09-APR-08:61 | 1.70 |
May | 60854251.48 | 28134.28 | 01-MAY-07:02 | -0.9 |
June | 53624983.61 | 1798.44 | 29-JUN-19:03 | 30.73 |
July | 60288081.49 | 1543.06 | 23-JUL-16:02 | 29.72 |
August | 46706046.42 | 745.50 | 08-AUG-19:03 | 26.42 |
September | 44741417.70 | 1459.56 | 23-SEP-07:10 | 4.37 |
October | 0.424736E+09 | 29563.91 | 30-OCT-07:01 | -9.0 |
November | 0.222519E+10 | 35688.80 | 26-NOV-08:61 | -9.3 |
December | 0.673296E+10 | 36215.19 | 19-DEC-07:01 | -25.8 |
Annual Sum or Average | 0.250703E+11 | |||
Minimum of Months | 44741417.70 | 745.50 | -25.8 | |
Maximum of Months | 0.731371E+10 | 36215.19 | 30.73 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.771162E+10 | 36119.12 | 01-JAN-08:61 | -26.7 |
February | 0.459880E+10 | 36016.28 | 19-FEB-08:61 | -23.5 |
March | 0.339223E+10 | 36038.89 | 06-MAR-07:01 | -19.3 |
April | 0.845753E+09 | 32159.87 | 08-APR-07:01 | 4.60 |
May | 66365508.39 | 30746.28 | 01-MAY-07:02 | -0.9 |
June | 53826032.14 | 1802.93 | 29-JUN-19:03 | 30.73 |
July | 60747984.71 | 1545.99 | 23-JUL-16:02 | 29.72 |
August | 46743159.60 | 751.23 | 08-AUG-19:03 | 26.42 |
September | 44728997.89 | 1523.39 | 23-SEP-07:10 | 4.37 |
October | 0.490098E+09 | 29516.72 | 30-OCT-07:01 | -9.0 |
November | 0.247358E+10 | 35603.93 | 26-NOV-08:61 | -9.3 |
December | 0.712206E+10 | 36151.28 | 19-DEC-07:01 | -25.8 |
Annual Sum or Average | 0.269066E+11 | |||
Minimum of Months | 44728997.89 | 751.23 | -26.7 | |
Maximum of Months | 0.771162E+10 | 36151.28 | 30.73 |
Report: ZoneHeatingSummaryMonthly
For: LGSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.145584E+11 | 68823.13 | 13-JAN-08:61 | -31.5 |
February | 0.852088E+10 | 68748.05 | 19-FEB-09:01 | -21.4 |
March | 0.619517E+10 | 68672.08 | 14-MAR-07:01 | -15.5 |
April | 0.140115E+10 | 68082.13 | 04-APR-07:01 | -8.2 |
May | 0.109844E+09 | 66408.82 | 02-MAY-08:61 | 8.18 |
June | 95509688.88 | 2920.83 | 24-JUN-17:03 | 29.22 |
July | 0.117330E+09 | 3085.16 | 23-JUL-16:02 | 29.72 |
August | 93000818.18 | 1224.08 | 26-AUG-17:03 | 25.63 |
September | 83103538.92 | 846.50 | 27-SEP-07:25 | 6.70 |
October | 0.788050E+09 | 66240.05 | 31-OCT-08:61 | 7.15 |
November | 0.446961E+10 | 68427.26 | 29-NOV-08:61 | -15.8 |
December | 0.133879E+11 | 68915.49 | 25-DEC-09:01 | -26.7 |
Annual Sum or Average | 0.498200E+11 | |||
Minimum of Months | 83103538.92 | 846.50 | -31.5 | |
Maximum of Months | 0.145584E+11 | 68915.49 | 29.72 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.789274E+10 | 35181.18 | 13-JAN-08:61 | -31.5 |
February | 0.471075E+10 | 35114.88 | 27-FEB-08:61 | -17.9 |
March | 0.350241E+10 | 35101.30 | 14-MAR-07:01 | -15.5 |
April | 0.871975E+09 | 34790.80 | 04-APR-07:01 | -8.2 |
May | 63193968.17 | 32112.93 | 02-MAY-08:61 | 8.18 |
June | 48458782.33 | 1475.23 | 24-JUN-17:03 | 29.22 |
July | 57950224.71 | 1552.93 | 23-JUL-16:02 | 29.72 |
August | 45516942.43 | 627.77 | 26-AUG-17:03 | 25.63 |
September | 44695654.43 | 789.70 | 23-SEP-08:06 | 7.07 |
October | 0.527149E+09 | 31879.48 | 31-OCT-08:61 | 7.15 |
November | 0.256207E+10 | 34972.74 | 29-NOV-08:61 | -15.8 |
December | 0.729376E+10 | 35228.46 | 25-DEC-09:01 | -26.7 |
Annual Sum or Average | 0.276207E+11 | |||
Minimum of Months | 44695654.43 | 627.77 | -31.5 | |
Maximum of Months | 0.789274E+10 | 35228.46 | 29.72 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.795614E+10 | 35043.23 | 13-JAN-08:61 | -31.5 |
February | 0.478954E+10 | 35021.36 | 19-FEB-09:01 | -21.4 |
March | 0.359297E+10 | 34982.64 | 14-MAR-07:01 | -15.5 |
April | 0.945693E+09 | 34674.63 | 04-APR-07:01 | -8.2 |
May | 66879095.56 | 32032.92 | 02-MAY-08:61 | 8.18 |
June | 47965141.09 | 1477.49 | 24-JUN-17:03 | 29.22 |
July | 58130654.96 | 1554.76 | 23-JUL-16:02 | 29.72 |
August | 45369206.58 | 629.55 | 26-AUG-17:03 | 25.63 |
September | 44595338.04 | 1400.10 | 29-SEP-08:62 | 8.40 |
October | 0.584507E+09 | 31796.70 | 31-OCT-08:61 | 7.15 |
November | 0.264755E+10 | 34855.04 | 29-NOV-08:61 | -15.8 |
December | 0.736427E+10 | 35110.93 | 25-DEC-09:01 | -26.7 |
Annual Sum or Average | 0.281436E+11 | |||
Minimum of Months | 44595338.04 | 629.55 | -31.5 | |
Maximum of Months | 0.795614E+10 | 35110.93 | 29.72 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.851150E+10 | 35072.16 | 13-JAN-08:61 | -31.5 |
February | 0.526660E+10 | 35000.96 | 19-FEB-09:01 | -21.4 |
March | 0.410282E+10 | 34995.18 | 12-MAR-08:61 | -21.0 |
April | 0.121782E+10 | 34833.71 | 06-APR-07:01 | -4.6 |
May | 87889388.27 | 32149.39 | 02-MAY-08:61 | 8.18 |
June | 48145455.18 | 1485.39 | 24-JUN-17:03 | 29.22 |
July | 58431124.58 | 1557.95 | 23-JUL-16:02 | 29.72 |
August | 45482958.01 | 633.68 | 26-AUG-17:03 | 25.63 |
September | 49741759.47 | 8012.74 | 29-SEP-08:62 | 8.40 |
October | 0.758781E+09 | 33515.43 | 30-OCT-07:01 | -9.0 |
November | 0.305521E+10 | 34848.55 | 29-NOV-08:61 | -15.8 |
December | 0.789108E+10 | 35034.86 | 21-DEC-08:61 | -28.4 |
Annual Sum or Average | 0.310935E+11 | |||
Minimum of Months | 45482958.01 | 633.68 | -31.5 | |
Maximum of Months | 0.851150E+10 | 35072.16 | 29.72 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE8
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.139892E+11 | 39960.33 | 05-JAN-08:61 | -32.3 |
February | 0.939926E+10 | 39883.30 | 17-FEB-08:61 | -28.5 |
March | 0.758735E+10 | 39820.03 | 05-MAR-09:01 | -20.9 |
April | 0.270118E+10 | 39523.01 | 03-APR-07:01 | -3.0 |
May | 0.224011E+09 | 38696.80 | 01-MAY-07:02 | -0.9 |
June | 54196907.63 | 1533.80 | 24-JUN-17:03 | 29.22 |
July | 64594348.97 | 1570.51 | 29-JUL-17:03 | 29.72 |
August | 52557267.11 | 671.38 | 26-AUG-17:03 | 25.63 |
September | 0.107399E+09 | 26407.59 | 28-SEP-08:62 | 7.30 |
October | 0.163170E+10 | 39371.92 | 30-OCT-07:01 | -9.0 |
November | 0.545132E+10 | 39615.99 | 26-NOV-09:01 | -8.8 |
December | 0.129007E+11 | 40063.97 | 25-DEC-09:01 | -26.7 |
Annual Sum or Average | 0.541635E+11 | |||
Minimum of Months | 52557267.11 | 671.38 | -32.3 | |
Maximum of Months | 0.139892E+11 | 40063.97 | 29.72 |
Report: ZoneElectricSummaryMonthly
For: LGSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.869933E+10 | 5321.43 | 01-JAN-10:09 | 0.223514E+10 | 1348.26 | 01-JAN-10:09 |
February | 0.786449E+10 | 5321.43 | 01-FEB-10:09 | 0.202238E+10 | 1348.26 | 01-FEB-10:09 |
March | 0.870841E+10 | 5321.43 | 01-MAR-10:09 | 0.224215E+10 | 1348.26 | 01-MAR-10:09 |
April | 0.843013E+10 | 5321.43 | 01-APR-09:09 | 0.216638E+10 | 1348.26 | 01-APR-09:09 |
May | 0.869933E+10 | 5321.43 | 01-MAY-09:09 | 0.223514E+10 | 1348.26 | 01-MAY-09:09 |
June | 0.843013E+10 | 5321.43 | 01-JUN-09:09 | 0.217123E+10 | 1348.26 | 01-JUN-09:09 |
July | 0.870841E+10 | 5321.43 | 01-JUL-09:09 | 0.223729E+10 | 1348.26 | 01-JUL-09:09 |
August | 0.869933E+10 | 5321.43 | 01-AUG-09:09 | 0.223756E+10 | 1348.26 | 01-AUG-09:09 |
September | 0.843920E+10 | 5321.43 | 01-SEP-09:09 | 0.217096E+10 | 1348.26 | 01-SEP-09:09 |
October | 0.869933E+10 | 5321.43 | 01-OCT-09:09 | 0.223514E+10 | 1348.26 | 01-OCT-09:09 |
November | 0.840290E+10 | 5321.43 | 01-NOV-09:09 | 0.215964E+10 | 1348.26 | 01-NOV-09:09 |
December | 0.871748E+10 | 5321.43 | 01-DEC-10:09 | 0.224431E+10 | 1348.26 | 01-DEC-10:09 |
Annual Sum or Average | 0.102498E+12 | 0.263573E+11 | ||||
Minimum of Months | 0.786449E+10 | 5321.43 | 0.202238E+10 | 1348.26 | ||
Maximum of Months | 0.871748E+10 | 5321.43 | 0.224431E+10 | 1348.26 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.479410E+10 | 2932.57 | 01-JAN-10:09 | 0.111757E+10 | 674.13 | 01-JAN-10:09 |
February | 0.433403E+10 | 2932.57 | 01-FEB-10:09 | 0.101119E+10 | 674.13 | 01-FEB-10:09 |
March | 0.479910E+10 | 2932.57 | 01-MAR-10:09 | 0.112107E+10 | 674.13 | 01-MAR-10:09 |
April | 0.464574E+10 | 2932.57 | 01-APR-09:09 | 0.108319E+10 | 674.13 | 01-APR-09:09 |
May | 0.479410E+10 | 2932.57 | 01-MAY-09:09 | 0.111757E+10 | 674.13 | 01-MAY-09:09 |
June | 0.464574E+10 | 2932.57 | 01-JUN-09:09 | 0.108562E+10 | 674.13 | 01-JUN-09:09 |
July | 0.479910E+10 | 2932.57 | 01-JUL-09:09 | 0.111865E+10 | 674.13 | 01-JUL-09:09 |
August | 0.479410E+10 | 2932.57 | 01-AUG-09:09 | 0.111878E+10 | 674.13 | 01-AUG-09:09 |
September | 0.465074E+10 | 2932.57 | 01-SEP-09:09 | 0.108548E+10 | 674.13 | 01-SEP-09:09 |
October | 0.479410E+10 | 2932.57 | 01-OCT-09:09 | 0.111757E+10 | 674.13 | 01-OCT-09:09 |
November | 0.463074E+10 | 2932.57 | 01-NOV-09:09 | 0.107982E+10 | 674.13 | 01-NOV-09:09 |
December | 0.480410E+10 | 2932.57 | 01-DEC-10:09 | 0.112215E+10 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.564857E+11 | 0.131787E+11 | ||||
Minimum of Months | 0.433403E+10 | 2932.57 | 0.101119E+10 | 674.13 | ||
Maximum of Months | 0.480410E+10 | 2932.57 | 0.112215E+10 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.338042E+10 | 2599.23 | 01-JAN-10:09 | 0.883781E+09 | 674.13 | 01-JAN-10:09 |
February | 0.306129E+10 | 2599.23 | 01-FEB-09:09 | 0.800324E+09 | 674.13 | 01-FEB-09:09 |
March | 0.345133E+10 | 2599.23 | 01-MAR-09:09 | 0.902118E+09 | 674.13 | 01-MAR-09:09 |
April | 0.327995E+10 | 2599.23 | 01-APR-08:09 | 0.857490E+09 | 674.13 | 01-APR-08:09 |
May | 0.341588E+10 | 2599.23 | 01-MAY-08:09 | 0.892950E+09 | 674.13 | 01-MAY-08:09 |
June | 0.333314E+10 | 2599.23 | 01-JUN-08:09 | 0.871243E+09 | 674.13 | 01-JUN-08:09 |
July | 0.336269E+10 | 2599.23 | 01-JUL-08:09 | 0.879197E+09 | 674.13 | 01-JUL-08:09 |
August | 0.345133E+10 | 2599.23 | 01-AUG-08:09 | 0.902118E+09 | 674.13 | 01-AUG-08:09 |
September | 0.327995E+10 | 2599.23 | 01-SEP-08:09 | 0.857490E+09 | 674.13 | 01-SEP-08:09 |
October | 0.338042E+10 | 2599.23 | 01-OCT-09:09 | 0.883781E+09 | 674.13 | 01-OCT-09:09 |
November | 0.327995E+10 | 2599.23 | 01-NOV-08:09 | 0.857490E+09 | 674.13 | 01-NOV-08:09 |
December | 0.336269E+10 | 2599.23 | 01-DEC-09:09 | 0.879197E+09 | 674.13 | 01-DEC-09:09 |
Annual Sum or Average | 0.400390E+11 | 0.104672E+11 | ||||
Minimum of Months | 0.306129E+10 | 2599.23 | 0.800324E+09 | 674.13 | ||
Maximum of Months | 0.345133E+10 | 2599.23 | 0.902118E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.338042E+10 | 2599.23 | 01-JAN-10:09 | 0.883781E+09 | 674.13 | 01-JAN-10:09 |
February | 0.306129E+10 | 2599.23 | 01-FEB-09:09 | 0.800324E+09 | 674.13 | 01-FEB-09:09 |
March | 0.345133E+10 | 2599.23 | 01-MAR-09:09 | 0.902118E+09 | 674.13 | 01-MAR-09:09 |
April | 0.327995E+10 | 2599.23 | 01-APR-08:09 | 0.857490E+09 | 674.13 | 01-APR-08:09 |
May | 0.341588E+10 | 2599.23 | 01-MAY-08:09 | 0.892950E+09 | 674.13 | 01-MAY-08:09 |
June | 0.333314E+10 | 2599.23 | 01-JUN-08:09 | 0.871243E+09 | 674.13 | 01-JUN-08:09 |
July | 0.336269E+10 | 2599.23 | 01-JUL-08:09 | 0.879197E+09 | 674.13 | 01-JUL-08:09 |
August | 0.345133E+10 | 2599.23 | 01-AUG-08:09 | 0.902118E+09 | 674.13 | 01-AUG-08:09 |
September | 0.327995E+10 | 2599.23 | 01-SEP-08:09 | 0.857490E+09 | 674.13 | 01-SEP-08:09 |
October | 0.338042E+10 | 2599.23 | 01-OCT-09:09 | 0.883781E+09 | 674.13 | 01-OCT-09:09 |
November | 0.327995E+10 | 2599.23 | 01-NOV-08:09 | 0.857490E+09 | 674.13 | 01-NOV-08:09 |
December | 0.336269E+10 | 2599.23 | 01-DEC-09:09 | 0.879197E+09 | 674.13 | 01-DEC-09:09 |
Annual Sum or Average | 0.400390E+11 | 0.104672E+11 | ||||
Minimum of Months | 0.306129E+10 | 2599.23 | 0.800324E+09 | 674.13 | ||
Maximum of Months | 0.345133E+10 | 2599.23 | 0.902118E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.338042E+10 | 2599.23 | 01-JAN-10:09 | 0.883781E+09 | 674.13 | 01-JAN-10:09 |
February | 0.306129E+10 | 2599.23 | 01-FEB-09:09 | 0.800324E+09 | 674.13 | 01-FEB-09:09 |
March | 0.345133E+10 | 2599.23 | 01-MAR-09:09 | 0.902118E+09 | 674.13 | 01-MAR-09:09 |
April | 0.327995E+10 | 2599.23 | 01-APR-08:09 | 0.857490E+09 | 674.13 | 01-APR-08:09 |
May | 0.341588E+10 | 2599.23 | 01-MAY-08:09 | 0.892950E+09 | 674.13 | 01-MAY-08:09 |
June | 0.333314E+10 | 2599.23 | 01-JUN-08:09 | 0.871243E+09 | 674.13 | 01-JUN-08:09 |
July | 0.336269E+10 | 2599.23 | 01-JUL-08:09 | 0.879197E+09 | 674.13 | 01-JUL-08:09 |
August | 0.345133E+10 | 2599.23 | 01-AUG-08:09 | 0.902118E+09 | 674.13 | 01-AUG-08:09 |
September | 0.327995E+10 | 2599.23 | 01-SEP-08:09 | 0.857490E+09 | 674.13 | 01-SEP-08:09 |
October | 0.338042E+10 | 2599.23 | 01-OCT-09:09 | 0.883781E+09 | 674.13 | 01-OCT-09:09 |
November | 0.327995E+10 | 2599.23 | 01-NOV-08:09 | 0.857490E+09 | 674.13 | 01-NOV-08:09 |
December | 0.336269E+10 | 2599.23 | 01-DEC-09:09 | 0.879197E+09 | 674.13 | 01-DEC-09:09 |
Annual Sum or Average | 0.400390E+11 | 0.104672E+11 | ||||
Minimum of Months | 0.306129E+10 | 2599.23 | 0.800324E+09 | 674.13 | ||
Maximum of Months | 0.345133E+10 | 2599.23 | 0.902118E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: LGSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.447638E+10 | 3746.51 | 01-JAN-11:09 | 0.162546E+10 | 1348.26 | 01-JAN-11:09 |
February | 0.405472E+10 | 3746.51 | 01-FEB-10:09 | 0.147229E+10 | 1348.26 | 01-FEB-10:09 |
March | 0.457860E+10 | 3746.51 | 01-MAR-10:09 | 0.166213E+10 | 1348.26 | 01-MAR-10:09 |
April | 0.434435E+10 | 3746.51 | 01-APR-09:09 | 0.157746E+10 | 1348.26 | 01-APR-09:09 |
May | 0.452749E+10 | 3746.51 | 01-MAY-09:09 | 0.164379E+10 | 1348.26 | 01-MAY-09:09 |
June | 0.442101E+10 | 3746.51 | 01-JUN-09:09 | 0.160496E+10 | 1348.26 | 01-JUN-09:09 |
July | 0.445083E+10 | 3746.51 | 01-JUL-09:09 | 0.161629E+10 | 1348.26 | 01-JUL-09:09 |
August | 0.457860E+10 | 3746.51 | 01-AUG-09:09 | 0.166213E+10 | 1348.26 | 01-AUG-09:09 |
September | 0.434435E+10 | 3746.51 | 01-SEP-09:09 | 0.157746E+10 | 1348.26 | 01-SEP-09:09 |
October | 0.447638E+10 | 3746.51 | 01-OCT-10:09 | 0.162546E+10 | 1348.26 | 01-OCT-10:09 |
November | 0.434435E+10 | 3746.51 | 01-NOV-09:09 | 0.157746E+10 | 1348.26 | 01-NOV-09:09 |
December | 0.445083E+10 | 3746.51 | 01-DEC-10:09 | 0.161629E+10 | 1348.26 | 01-DEC-10:09 |
Annual Sum or Average | 0.530479E+11 | 0.192612E+11 | ||||
Minimum of Months | 0.405472E+10 | 3746.51 | 0.147229E+10 | 1348.26 | ||
Maximum of Months | 0.457860E+10 | 3746.51 | 0.166213E+10 | 1348.26 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.230731E+10 | 1931.10 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.208997E+10 | 1931.10 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.236000E+10 | 1931.10 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.223926E+10 | 1931.10 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.233366E+10 | 1931.10 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.227877E+10 | 1931.10 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.229414E+10 | 1931.10 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.236000E+10 | 1931.10 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.223926E+10 | 1931.10 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.230731E+10 | 1931.10 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.223926E+10 | 1931.10 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.229414E+10 | 1931.10 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.273431E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.208997E+10 | 1931.10 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.236000E+10 | 1931.10 | 0.831065E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.230731E+10 | 1931.10 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.208997E+10 | 1931.10 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.236000E+10 | 1931.10 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.223926E+10 | 1931.10 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.233366E+10 | 1931.10 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.227877E+10 | 1931.10 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.229414E+10 | 1931.10 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.236000E+10 | 1931.10 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.223926E+10 | 1931.10 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.230731E+10 | 1931.10 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.223926E+10 | 1931.10 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.229414E+10 | 1931.10 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.273431E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.208997E+10 | 1931.10 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.236000E+10 | 1931.10 | 0.831065E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.230731E+10 | 1931.10 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.208997E+10 | 1931.10 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.236000E+10 | 1931.10 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.223926E+10 | 1931.10 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.233366E+10 | 1931.10 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.227877E+10 | 1931.10 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.229414E+10 | 1931.10 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.236000E+10 | 1931.10 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.223926E+10 | 1931.10 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.230731E+10 | 1931.10 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.223926E+10 | 1931.10 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.229414E+10 | 1931.10 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.273431E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.208997E+10 | 1931.10 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.236000E+10 | 1931.10 | 0.831065E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE8
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.230731E+10 | 1931.10 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.208997E+10 | 1931.10 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.236000E+10 | 1931.10 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.223926E+10 | 1931.10 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.233366E+10 | 1931.10 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.227877E+10 | 1931.10 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.229414E+10 | 1931.10 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.236000E+10 | 1931.10 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.223926E+10 | 1931.10 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.230731E+10 | 1931.10 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.223926E+10 | 1931.10 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.229414E+10 | 1931.10 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.273431E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.208997E+10 | 1931.10 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.236000E+10 | 1931.10 | 0.831065E+09 | 674.13 |
Report: SpaceGainsMonthly
For: LGSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.338624E+10 | 0.869933E+10 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107933E+11 |
February | 0.305697E+10 | 0.786449E+10 | 0.202238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.790225E+10 |
March | 0.335708E+10 | 0.870841E+10 | 0.224215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.687758E+10 |
April | 0.327081E+10 | 0.843013E+10 | 0.216638E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7123173.70 | 0.421263E+10 |
May | 0.336680E+10 | 0.869933E+10 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102758E+09 | 0.196125E+10 |
June | 0.325380E+10 | 0.843013E+10 | 0.217123E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.249767E+09 | 0.981316E+09 |
July | 0.339353E+10 | 0.870841E+10 | 0.223729E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.354740E+09 | 0.616241E+09 |
August | 0.334857E+10 | 0.869933E+10 | 0.223756E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147951E+09 | 0.962401E+09 |
September | 0.327932E+10 | 0.843920E+10 | 0.217096E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7116442.02 | 0.228072E+10 |
October | 0.338624E+10 | 0.869933E+10 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.392821E+10 |
November | 0.327446E+10 | 0.840290E+10 | 0.215964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.609463E+10 |
December | 0.340325E+10 | 0.871748E+10 | 0.224431E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104580E+11 |
Annual Sum or Average | 0.397770E+11 | 0.102498E+12 | 0.263573E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.869457E+09 | 0.570684E+11 |
Minimum of Months | 0.305697E+10 | 0.786449E+10 | 0.202238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.616241E+09 |
Maximum of Months | 0.340325E+10 | 0.871748E+10 | 0.224431E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.354740E+09 | 0.107933E+11 |
Report: SpaceGainsMonthly
For: SMSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.169307E+10 | 0.479410E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.543754E+10 |
February | 0.152844E+10 | 0.433403E+10 | 0.101119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.391903E+10 |
March | 0.167849E+10 | 0.479910E+10 | 0.112107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.346941E+10 |
April | 0.163536E+10 | 0.464574E+10 | 0.108319E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3746507.87 | 0.201575E+10 |
May | 0.168335E+10 | 0.479410E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 55958711.22 | 0.903137E+09 |
June | 0.162685E+10 | 0.464574E+10 | 0.108562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134031E+09 | 0.452153E+09 |
July | 0.169671E+10 | 0.479910E+10 | 0.111865E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192354E+09 | 0.281390E+09 |
August | 0.167424E+10 | 0.479410E+10 | 0.111878E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 80354388.45 | 0.439234E+09 |
September | 0.163961E+10 | 0.465074E+10 | 0.108548E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3898476.78 | 0.106174E+10 |
October | 0.169307E+10 | 0.479410E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.191648E+10 |
November | 0.163718E+10 | 0.463074E+10 | 0.107982E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.300331E+10 |
December | 0.170157E+10 | 0.480410E+10 | 0.112215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.524014E+10 |
Annual Sum or Average | 0.198880E+11 | 0.564857E+11 | 0.131787E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.470343E+09 | 0.281393E+11 |
Minimum of Months | 0.152844E+10 | 0.433403E+10 | 0.101119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281390E+09 |
Maximum of Months | 0.170157E+10 | 0.480410E+10 | 0.112215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192354E+09 | 0.543754E+10 |
Report: SpaceGainsMonthly
For: SMSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.100722E+10 | 0.338042E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.555430E+10 |
February | 0.914877E+09 | 0.306129E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.403811E+10 |
March | 0.103395E+10 | 0.345133E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.353744E+10 |
April | 0.984131E+09 | 0.327995E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2584376.36 | 0.205585E+10 |
May | 0.102058E+10 | 0.341588E+10 | 0.892950E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 55947412.11 | 0.915576E+09 |
June | 0.998711E+09 | 0.333314E+10 | 0.871243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132947E+09 | 0.467519E+09 |
July | 0.100600E+10 | 0.336269E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188358E+09 | 0.300195E+09 |
August | 0.103395E+10 | 0.345133E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 80267567.12 | 0.461408E+09 |
September | 0.984131E+09 | 0.327995E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3898344.17 | 0.106841E+10 |
October | 0.100722E+10 | 0.338042E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.194072E+10 |
November | 0.973196E+09 | 0.327995E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.308086E+10 |
December | 0.100600E+10 | 0.336269E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.537423E+10 |
Annual Sum or Average | 0.119700E+11 | 0.400390E+11 | 0.104672E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.464002E+09 | 0.287946E+11 |
Minimum of Months | 0.914877E+09 | 0.306129E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.300195E+09 |
Maximum of Months | 0.103395E+10 | 0.345133E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188358E+09 | 0.555430E+10 |
Report: SpaceGainsMonthly
For: SMSTORE3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.100722E+10 | 0.338042E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.554964E+10 |
February | 0.914877E+09 | 0.306129E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.403335E+10 |
March | 0.103395E+10 | 0.345133E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.353398E+10 |
April | 0.984131E+09 | 0.327995E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2659700.79 | 0.204785E+10 |
May | 0.102058E+10 | 0.341588E+10 | 0.892950E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 55947382.29 | 0.908283E+09 |
June | 0.998711E+09 | 0.333314E+10 | 0.871243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132917E+09 | 0.465312E+09 |
July | 0.100600E+10 | 0.336269E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188330E+09 | 0.300231E+09 |
August | 0.103395E+10 | 0.345133E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 80267503.20 | 0.460854E+09 |
September | 0.984131E+09 | 0.327995E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3898335.47 | 0.106258E+10 |
October | 0.100722E+10 | 0.338042E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.193318E+10 |
November | 0.973196E+09 | 0.327995E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.307549E+10 |
December | 0.100600E+10 | 0.336269E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.536908E+10 |
Annual Sum or Average | 0.119700E+11 | 0.400390E+11 | 0.104672E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.464021E+09 | 0.287398E+11 |
Minimum of Months | 0.914877E+09 | 0.306129E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.300231E+09 |
Maximum of Months | 0.103395E+10 | 0.345133E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188330E+09 | 0.554964E+10 |
Report: SpaceGainsMonthly
For: SMSTORE4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.100722E+10 | 0.338042E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.554663E+10 |
February | 0.914877E+09 | 0.306129E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.402996E+10 |
March | 0.103395E+10 | 0.345133E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.353129E+10 |
April | 0.984131E+09 | 0.327995E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2700511.14 | 0.204373E+10 |
May | 0.102058E+10 | 0.341588E+10 | 0.892950E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 55947384.64 | 0.905088E+09 |
June | 0.998711E+09 | 0.333314E+10 | 0.871243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132995E+09 | 0.463143E+09 |
July | 0.100600E+10 | 0.336269E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188377E+09 | 0.298697E+09 |
August | 0.103395E+10 | 0.345133E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 80267429.78 | 0.459113E+09 |
September | 0.984131E+09 | 0.327995E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3898273.81 | 0.106119E+10 |
October | 0.100722E+10 | 0.338042E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.193148E+10 |
November | 0.973196E+09 | 0.327995E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.307130E+10 |
December | 0.100600E+10 | 0.336269E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.536564E+10 |
Annual Sum or Average | 0.119700E+11 | 0.400390E+11 | 0.104672E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.464186E+09 | 0.287073E+11 |
Minimum of Months | 0.914877E+09 | 0.306129E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.298697E+09 |
Maximum of Months | 0.103395E+10 | 0.345133E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188377E+09 | 0.554663E+10 |
Report: SpaceGainsMonthly
For: LGSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.344359E+10 | 0.447638E+10 | 0.162546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101412E+11 |
February | 0.313522E+10 | 0.405472E+10 | 0.147229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.738577E+10 |
March | 0.355148E+10 | 0.457860E+10 | 0.166213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.645266E+10 |
April | 0.338259E+10 | 0.434435E+10 | 0.157746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4920348.46 | 0.385322E+10 |
May | 0.349753E+10 | 0.452749E+10 | 0.164379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100622E+09 | 0.179066E+10 |
June | 0.343071E+10 | 0.442101E+10 | 0.160496E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.239723E+09 | 0.894268E+09 |
July | 0.344942E+10 | 0.445083E+10 | 0.161629E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.338811E+09 | 0.571146E+09 |
August | 0.355148E+10 | 0.457860E+10 | 0.166213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144427E+09 | 0.877001E+09 |
September | 0.338259E+10 | 0.434435E+10 | 0.157746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7004460.44 | 0.208691E+10 |
October | 0.344359E+10 | 0.447638E+10 | 0.162546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.365064E+10 |
November | 0.331698E+10 | 0.434435E+10 | 0.157746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.564691E+10 |
December | 0.344942E+10 | 0.445083E+10 | 0.161629E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.982245E+10 |
Annual Sum or Average | 0.410346E+11 | 0.530479E+11 | 0.192612E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.835508E+09 | 0.531729E+11 |
Minimum of Months | 0.313522E+10 | 0.405472E+10 | 0.147229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.571146E+09 |
Maximum of Months | 0.355148E+10 | 0.457860E+10 | 0.166213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.338811E+09 | 0.101412E+11 |
Report: SpaceGainsMonthly
For: SMSTORE5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.172174E+10 | 0.230731E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.556859E+10 |
February | 0.156756E+10 | 0.208997E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.404350E+10 |
March | 0.177569E+10 | 0.236000E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.354198E+10 |
April | 0.169125E+10 | 0.223926E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2890239.71 | 0.204922E+10 |
May | 0.174872E+10 | 0.233366E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 55958000.46 | 0.905493E+09 |
June | 0.171530E+10 | 0.227877E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133153E+09 | 0.464595E+09 |
July | 0.172466E+10 | 0.229414E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188419E+09 | 0.303177E+09 |
August | 0.177569E+10 | 0.236000E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 80293391.69 | 0.464574E+09 |
September | 0.169125E+10 | 0.223926E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3898240.75 | 0.106857E+10 |
October | 0.172174E+10 | 0.230731E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.193660E+10 |
November | 0.165844E+10 | 0.223926E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.308259E+10 |
December | 0.172466E+10 | 0.229414E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.538751E+10 |
Annual Sum or Average | 0.205167E+11 | 0.273431E+11 | 0.963059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.464611E+09 | 0.288164E+11 |
Minimum of Months | 0.156756E+10 | 0.208997E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.303177E+09 |
Maximum of Months | 0.177569E+10 | 0.236000E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188419E+09 | 0.556859E+10 |
Report: SpaceGainsMonthly
For: SMSTORE6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.172174E+10 | 0.230731E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.556808E+10 |
February | 0.156756E+10 | 0.208997E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.404262E+10 |
March | 0.177569E+10 | 0.236000E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.354092E+10 |
April | 0.169125E+10 | 0.223926E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3012599.27 | 0.204105E+10 |
May | 0.174872E+10 | 0.233366E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 55958107.12 | 0.892017E+09 |
June | 0.171530E+10 | 0.227877E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133188E+09 | 0.458483E+09 |
July | 0.172466E+10 | 0.229414E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188447E+09 | 0.301665E+09 |
August | 0.177569E+10 | 0.236000E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 80293637.13 | 0.462178E+09 |
September | 0.169125E+10 | 0.223926E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3898205.14 | 0.105770E+10 |
October | 0.172174E+10 | 0.230731E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192853E+10 |
November | 0.165844E+10 | 0.223926E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.308055E+10 |
December | 0.172466E+10 | 0.229414E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.538683E+10 |
Annual Sum or Average | 0.205167E+11 | 0.273431E+11 | 0.963059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.464798E+09 | 0.287606E+11 |
Minimum of Months | 0.156756E+10 | 0.208997E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.301665E+09 |
Maximum of Months | 0.177569E+10 | 0.236000E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188447E+09 | 0.556808E+10 |
Report: SpaceGainsMonthly
For: SMSTORE7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.172174E+10 | 0.230731E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.556392E+10 |
February | 0.156756E+10 | 0.208997E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.403739E+10 |
March | 0.177569E+10 | 0.236000E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.353534E+10 |
April | 0.169125E+10 | 0.223926E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3221010.47 | 0.202529E+10 |
May | 0.174872E+10 | 0.233366E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 55959067.37 | 0.871080E+09 |
June | 0.171530E+10 | 0.227877E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133283E+09 | 0.446751E+09 |
July | 0.172466E+10 | 0.229414E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188501E+09 | 0.297625E+09 |
August | 0.177569E+10 | 0.236000E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 80293579.53 | 0.456791E+09 |
September | 0.169125E+10 | 0.223926E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3898142.69 | 0.104319E+10 |
October | 0.172174E+10 | 0.230731E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.191761E+10 |
November | 0.165844E+10 | 0.223926E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.307237E+10 |
December | 0.172466E+10 | 0.229414E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.538149E+10 |
Annual Sum or Average | 0.205167E+11 | 0.273431E+11 | 0.963059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.465155E+09 | 0.286488E+11 |
Minimum of Months | 0.156756E+10 | 0.208997E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.297625E+09 |
Maximum of Months | 0.177569E+10 | 0.236000E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188501E+09 | 0.556392E+10 |
Report: SpaceGainsMonthly
For: SMSTORE8
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.172174E+10 | 0.230731E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.668412E+10 |
February | 0.156756E+10 | 0.208997E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.499373E+10 |
March | 0.177569E+10 | 0.236000E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.420297E+10 |
April | 0.169125E+10 | 0.223926E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4374970.90 | 0.253050E+10 |
May | 0.174872E+10 | 0.233366E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 58094464.27 | 0.109164E+10 |
June | 0.171530E+10 | 0.227877E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141973E+09 | 0.574981E+09 |
July | 0.172466E+10 | 0.229414E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.196717E+09 | 0.402211E+09 |
August | 0.177569E+10 | 0.236000E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 83696554.09 | 0.614471E+09 |
September | 0.169125E+10 | 0.223926E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4008995.33 | 0.130396E+10 |
October | 0.172174E+10 | 0.230731E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.229774E+10 |
November | 0.165844E+10 | 0.223926E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.378392E+10 |
December | 0.172466E+10 | 0.229414E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.653866E+10 |
Annual Sum or Average | 0.205167E+11 | 0.273431E+11 | 0.963059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.488866E+09 | 0.350189E+11 |
Minimum of Months | 0.156756E+10 | 0.208997E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.402211E+09 |
Maximum of Months | 0.177569E+10 | 0.236000E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.196717E+09 | 0.668412E+10 |
Report: PeakSpaceGainsMonthly
For: LGSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 4050.04 | 01-JAN-13:09 | 5321.43 | 01-JAN-10:09 | 1348.26 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 18193.23 | 04-JAN-12:10 |
February | 4050.04 | 03-FEB-13:09 | 5321.43 | 01-FEB-10:09 | 1348.26 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 14908.32 | 13-FEB-12:10 |
March | 4050.04 | 03-MAR-13:09 | 5321.43 | 01-MAR-10:09 | 1348.26 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 12263.51 | 15-MAR-11:10 |
April | 4050.04 | 01-APR-12:09 | 5321.43 | 01-APR-09:09 | 1348.26 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 843.00 | 23-APR-16:00 | 8513.93 | 04-APR-17:00 |
May | 4050.04 | 05-MAY-12:09 | 5321.43 | 01-MAY-09:09 | 1348.26 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1467.22 | 25-MAY-17:00 | 4874.37 | 08-MAY-11:05 |
June | 4050.04 | 02-JUN-12:09 | 5321.43 | 01-JUN-09:09 | 1348.26 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3160.93 | 29-JUN-16:00 | 3599.22 | 09-JUN-11:10 |
July | 4050.04 | 01-JUL-12:09 | 5321.43 | 01-JUL-09:09 | 1348.26 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2106.96 | 15-JUL-15:00 | 3199.39 | 08-JUL-12:00 |
August | 4050.04 | 04-AUG-12:09 | 5321.43 | 01-AUG-09:09 | 1348.26 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1964.88 | 08-AUG-16:00 | 4199.67 | 17-AUG-14:00 |
September | 4050.04 | 01-SEP-12:09 | 5321.43 | 01-SEP-09:09 | 1348.26 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 626.42 | 01-SEP-15:00 | 4935.89 | 27-SEP-11:05 |
October | 4050.04 | 01-OCT-12:09 | 5321.43 | 01-OCT-09:09 | 1348.26 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 7095.57 | 31-OCT-17:00 |
November | 4050.04 | 03-NOV-12:09 | 5321.43 | 01-NOV-09:09 | 1348.26 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 12039.97 | 25-NOV-12:10 |
December | 4050.04 | 01-DEC-13:09 | 5321.43 | 01-DEC-10:09 | 1348.26 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 17459.21 | 24-DEC-12:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 4050.04 | 5321.43 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3199.39 | |||||
Maximum of Months | 4050.04 | 5321.43 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 3160.93 | 18193.23 |
Report: PeakSpaceGainsMonthly
For: SMSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2024.96 | 01-JAN-13:09 | 2932.57 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 9736.58 | 04-JAN-12:10 |
February | 2024.96 | 03-FEB-13:09 | 2932.57 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 8221.95 | 01-FEB-18:00 |
March | 2024.96 | 03-MAR-13:09 | 2932.57 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 6688.26 | 15-MAR-11:10 |
April | 2024.96 | 01-APR-12:09 | 2932.57 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 445.87 | 23-APR-16:00 | 4573.77 | 04-APR-11:10 |
May | 2024.96 | 05-MAY-12:09 | 2932.57 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 810.13 | 25-MAY-17:00 | 2466.15 | 08-MAY-11:05 |
June | 2024.96 | 02-JUN-12:09 | 2932.57 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1706.48 | 29-JUN-16:00 | 1832.17 | 02-JUN-11:10 |
July | 2024.96 | 01-JUL-12:09 | 2932.57 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1126.80 | 15-JUL-15:00 | 1685.37 | 08-JUL-11:10 |
August | 2024.96 | 04-AUG-12:09 | 2932.57 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1058.40 | 08-AUG-16:00 | 2063.97 | 17-AUG-14:00 |
September | 2024.96 | 01-SEP-12:09 | 2932.57 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 343.18 | 01-SEP-15:00 | 2437.73 | 27-SEP-11:05 |
October | 2024.96 | 01-OCT-12:09 | 2932.57 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3839.29 | 29-OCT-17:00 |
November | 2024.96 | 03-NOV-12:09 | 2932.57 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 6607.53 | 25-NOV-17:00 |
December | 2024.96 | 01-DEC-13:09 | 2932.57 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 9445.98 | 24-DEC-12:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 2024.96 | 2932.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1685.37 | |||||
Maximum of Months | 2024.96 | 2932.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1706.48 | 9736.58 |
Report: PeakSpaceGainsMonthly
For: SMSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2024.96 | 07-JAN-13:09 | 2599.23 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 9736.58 | 04-JAN-12:10 |
February | 2024.96 | 04-FEB-13:09 | 2599.23 | 01-FEB-09:09 | 674.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 8221.95 | 01-FEB-18:00 |
March | 2024.96 | 04-MAR-13:09 | 2599.23 | 01-MAR-09:09 | 674.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 6688.26 | 15-MAR-11:10 |
April | 2024.96 | 01-APR-12:09 | 2599.23 | 01-APR-08:09 | 674.13 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 445.87 | 23-APR-16:00 | 4573.77 | 04-APR-11:10 |
May | 2024.96 | 06-MAY-12:09 | 2599.23 | 01-MAY-08:09 | 674.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 810.13 | 25-MAY-17:00 | 2419.42 | 01-MAY-11:10 |
June | 2024.96 | 03-JUN-12:09 | 2599.23 | 01-JUN-08:09 | 674.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1706.48 | 29-JUN-16:00 | 1808.90 | 09-JUN-11:10 |
July | 2024.96 | 01-JUL-12:09 | 2599.23 | 01-JUL-08:09 | 674.13 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1126.80 | 15-JUL-15:00 | 1704.98 | 08-JUL-11:10 |
August | 2024.96 | 05-AUG-12:09 | 2599.23 | 01-AUG-08:09 | 674.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1058.40 | 08-AUG-16:00 | 2029.55 | 17-AUG-14:00 |
September | 2024.96 | 02-SEP-12:09 | 2599.23 | 01-SEP-08:09 | 674.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 343.18 | 01-SEP-15:00 | 2359.81 | 27-SEP-11:05 |
October | 2024.96 | 07-OCT-12:09 | 2599.23 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3839.29 | 29-OCT-17:00 |
November | 2024.96 | 04-NOV-12:09 | 2599.23 | 01-NOV-08:09 | 674.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 6607.53 | 25-NOV-17:00 |
December | 2024.96 | 02-DEC-13:09 | 2599.23 | 01-DEC-09:09 | 674.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 9445.98 | 24-DEC-12:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 2024.96 | 2599.23 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1704.98 | |||||
Maximum of Months | 2024.96 | 2599.23 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1706.48 | 9736.58 |
Report: PeakSpaceGainsMonthly
For: SMSTORE3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2024.96 | 07-JAN-13:09 | 2599.23 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 9736.58 | 04-JAN-12:10 |
February | 2024.96 | 04-FEB-13:09 | 2599.23 | 01-FEB-09:09 | 674.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 8221.95 | 01-FEB-18:00 |
March | 2024.96 | 04-MAR-13:09 | 2599.23 | 01-MAR-09:09 | 674.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 6688.26 | 15-MAR-11:10 |
April | 2024.96 | 01-APR-12:09 | 2599.23 | 01-APR-08:09 | 674.13 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 445.87 | 23-APR-16:00 | 4573.77 | 04-APR-11:10 |
May | 2024.96 | 06-MAY-12:09 | 2599.23 | 01-MAY-08:09 | 674.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 810.12 | 25-MAY-17:00 | 2419.42 | 01-MAY-11:10 |
June | 2024.96 | 03-JUN-12:09 | 2599.23 | 01-JUN-08:09 | 674.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1706.48 | 29-JUN-16:00 | 1806.76 | 09-JUN-11:10 |
July | 2024.96 | 01-JUL-12:09 | 2599.23 | 01-JUL-08:09 | 674.13 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1126.80 | 15-JUL-15:00 | 1705.25 | 08-JUL-11:10 |
August | 2024.96 | 05-AUG-12:09 | 2599.23 | 01-AUG-08:09 | 674.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1058.40 | 08-AUG-16:00 | 2024.13 | 17-AUG-14:00 |
September | 2024.96 | 02-SEP-12:09 | 2599.23 | 01-SEP-08:09 | 674.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 343.18 | 01-SEP-15:00 | 2331.79 | 27-SEP-11:05 |
October | 2024.96 | 07-OCT-12:09 | 2599.23 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3839.29 | 29-OCT-17:00 |
November | 2024.96 | 04-NOV-12:09 | 2599.23 | 01-NOV-08:09 | 674.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 6607.53 | 25-NOV-17:00 |
December | 2024.96 | 02-DEC-13:09 | 2599.23 | 01-DEC-09:09 | 674.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 9445.98 | 24-DEC-12:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 2024.96 | 2599.23 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1705.25 | |||||
Maximum of Months | 2024.96 | 2599.23 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1706.48 | 9736.58 |
Report: PeakSpaceGainsMonthly
For: SMSTORE4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2024.96 | 07-JAN-13:09 | 2599.23 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 9736.58 | 04-JAN-12:10 |
February | 2024.96 | 04-FEB-13:09 | 2599.23 | 01-FEB-09:09 | 674.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 8221.95 | 01-FEB-18:00 |
March | 2024.96 | 04-MAR-13:09 | 2599.23 | 01-MAR-09:09 | 674.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 6688.26 | 15-MAR-11:10 |
April | 2024.96 | 01-APR-12:09 | 2599.23 | 01-APR-08:09 | 674.13 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 445.87 | 23-APR-16:00 | 4573.77 | 04-APR-11:10 |
May | 2024.96 | 06-MAY-12:09 | 2599.23 | 01-MAY-08:09 | 674.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 810.12 | 25-MAY-17:00 | 2419.42 | 01-MAY-11:10 |
June | 2024.96 | 03-JUN-12:09 | 2599.23 | 01-JUN-08:09 | 674.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1706.48 | 29-JUN-16:00 | 1796.01 | 09-JUN-11:10 |
July | 2024.96 | 01-JUL-12:09 | 2599.23 | 01-JUL-08:09 | 674.13 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1126.80 | 15-JUL-15:00 | 1693.70 | 08-JUL-11:10 |
August | 2024.96 | 05-AUG-12:09 | 2599.23 | 01-AUG-08:09 | 674.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1058.40 | 08-AUG-16:00 | 2018.57 | 17-AUG-14:00 |
September | 2024.96 | 02-SEP-12:09 | 2599.23 | 01-SEP-08:09 | 674.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 343.18 | 01-SEP-15:00 | 2333.97 | 27-SEP-11:05 |
October | 2024.96 | 07-OCT-12:09 | 2599.23 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3839.29 | 29-OCT-17:00 |
November | 2024.96 | 04-NOV-12:09 | 2599.23 | 01-NOV-08:09 | 674.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 6607.53 | 25-NOV-17:00 |
December | 2024.96 | 02-DEC-13:09 | 2599.23 | 01-DEC-09:09 | 674.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 9445.98 | 24-DEC-12:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 2024.96 | 2599.23 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1693.70 | |||||
Maximum of Months | 2024.96 | 2599.23 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1706.48 | 9736.58 |
Report: PeakSpaceGainsMonthly
For: LGSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 5400.05 | 07-JAN-15:09 | 3746.51 | 01-JAN-11:09 | 1348.26 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 17546.75 | 04-JAN-12:10 |
February | 5400.05 | 04-FEB-15:09 | 3746.51 | 01-FEB-10:09 | 1348.26 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 14741.82 | 01-FEB-18:00 |
March | 5400.05 | 04-MAR-15:09 | 3746.51 | 01-MAR-10:09 | 1348.26 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 12024.86 | 15-MAR-11:10 |
April | 5400.05 | 01-APR-14:09 | 3746.51 | 01-APR-09:09 | 1348.26 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 804.68 | 23-APR-16:00 | 8228.43 | 04-APR-11:10 |
May | 5400.05 | 06-MAY-14:09 | 3746.51 | 01-MAY-09:09 | 1348.26 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1454.26 | 25-MAY-17:00 | 4827.13 | 08-MAY-11:05 |
June | 5400.05 | 03-JUN-14:09 | 3746.51 | 01-JUN-09:09 | 1348.26 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3071.96 | 29-JUN-16:00 | 3486.62 | 09-JUN-11:10 |
July | 5400.05 | 01-JUL-14:09 | 3746.51 | 01-JUL-09:09 | 1348.26 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2030.87 | 15-JUL-15:00 | 3146.38 | 08-JUL-12:00 |
August | 5400.05 | 05-AUG-14:09 | 3746.51 | 01-AUG-09:09 | 1348.26 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1905.84 | 08-AUG-16:00 | 4018.81 | 17-AUG-14:00 |
September | 5400.05 | 02-SEP-14:09 | 3746.51 | 01-SEP-09:09 | 1348.26 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 616.65 | 01-SEP-15:00 | 4843.23 | 27-SEP-11:05 |
October | 5400.05 | 07-OCT-14:09 | 3746.51 | 01-OCT-10:09 | 1348.26 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 6894.74 | 29-OCT-17:00 |
November | 5400.05 | 04-NOV-14:09 | 3746.51 | 01-NOV-09:09 | 1348.26 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 11862.45 | 25-NOV-17:00 |
December | 5400.05 | 02-DEC-15:09 | 3746.51 | 01-DEC-10:09 | 1348.26 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 16999.87 | 24-DEC-12:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 5400.05 | 3746.51 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3146.38 | |||||
Maximum of Months | 5400.05 | 3746.51 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 3071.96 | 17546.75 |
Report: PeakSpaceGainsMonthly
For: SMSTORE5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2699.95 | 07-JAN-15:09 | 1931.10 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 9736.58 | 04-JAN-12:10 |
February | 2699.95 | 04-FEB-15:09 | 1931.10 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 8221.95 | 01-FEB-18:00 |
March | 2699.95 | 04-MAR-15:09 | 1931.10 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 6688.26 | 15-MAR-11:10 |
April | 2699.95 | 01-APR-14:09 | 1931.10 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 445.86 | 23-APR-16:00 | 4573.77 | 04-APR-11:10 |
May | 2699.95 | 06-MAY-14:09 | 1931.10 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 810.12 | 25-MAY-17:00 | 2419.42 | 01-MAY-11:10 |
June | 2699.95 | 03-JUN-14:09 | 1931.10 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1706.48 | 29-JUN-16:00 | 1771.23 | 09-JUN-11:10 |
July | 2699.95 | 01-JUL-14:09 | 1931.10 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1126.80 | 15-JUL-15:00 | 1677.37 | 08-JUL-11:10 |
August | 2699.95 | 05-AUG-14:09 | 1931.10 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1058.40 | 08-AUG-16:00 | 1989.82 | 17-AUG-14:00 |
September | 2699.95 | 02-SEP-14:09 | 1931.10 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 343.19 | 01-SEP-15:00 | 2320.40 | 27-SEP-11:05 |
October | 2699.95 | 07-OCT-14:09 | 1931.10 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3839.29 | 29-OCT-17:00 |
November | 2699.95 | 04-NOV-14:09 | 1931.10 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 6607.53 | 25-NOV-17:00 |
December | 2699.95 | 02-DEC-15:09 | 1931.10 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 9445.98 | 24-DEC-12:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 2699.95 | 1931.10 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1677.37 | |||||
Maximum of Months | 2699.95 | 1931.10 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1706.48 | 9736.58 |
Report: PeakSpaceGainsMonthly
For: SMSTORE6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2699.95 | 07-JAN-15:09 | 1931.10 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 9736.58 | 04-JAN-12:10 |
February | 2699.95 | 04-FEB-15:09 | 1931.10 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 8221.95 | 01-FEB-18:00 |
March | 2699.95 | 04-MAR-15:09 | 1931.10 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 6688.26 | 15-MAR-11:10 |
April | 2699.95 | 01-APR-14:09 | 1931.10 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 445.87 | 23-APR-16:00 | 4573.77 | 04-APR-11:10 |
May | 2699.95 | 06-MAY-14:09 | 1931.10 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 810.12 | 25-MAY-17:00 | 2419.42 | 01-MAY-11:10 |
June | 2699.95 | 03-JUN-14:09 | 1931.10 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1706.48 | 29-JUN-16:00 | 1751.82 | 09-JUN-11:10 |
July | 2699.95 | 01-JUL-14:09 | 1931.10 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1126.80 | 15-JUL-15:00 | 1665.33 | 08-JUL-11:10 |
August | 2699.95 | 05-AUG-14:09 | 1931.10 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1058.40 | 08-AUG-16:00 | 1969.82 | 17-AUG-14:00 |
September | 2699.95 | 02-SEP-14:09 | 1931.10 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 343.19 | 01-SEP-15:00 | 2317.57 | 27-SEP-11:10 |
October | 2699.95 | 07-OCT-14:09 | 1931.10 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3839.29 | 29-OCT-17:00 |
November | 2699.95 | 04-NOV-14:09 | 1931.10 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 6607.53 | 25-NOV-17:00 |
December | 2699.95 | 02-DEC-15:09 | 1931.10 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 9445.98 | 24-DEC-12:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 2699.95 | 1931.10 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1665.33 | |||||
Maximum of Months | 2699.95 | 1931.10 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1706.48 | 9736.58 |
Report: PeakSpaceGainsMonthly
For: SMSTORE7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2699.95 | 07-JAN-15:09 | 1931.10 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 9736.58 | 04-JAN-12:10 |
February | 2699.95 | 04-FEB-15:09 | 1931.10 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 8221.95 | 01-FEB-18:00 |
March | 2699.95 | 04-MAR-15:09 | 1931.10 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 6688.26 | 15-MAR-11:10 |
April | 2699.95 | 01-APR-14:09 | 1931.10 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 445.95 | 23-APR-16:00 | 4573.77 | 04-APR-11:10 |
May | 2699.95 | 06-MAY-14:09 | 1931.10 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 810.11 | 25-MAY-17:00 | 2419.42 | 01-MAY-11:10 |
June | 2699.95 | 03-JUN-14:09 | 1931.10 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1706.48 | 29-JUN-16:00 | 1711.93 | 09-JUN-11:10 |
July | 2699.95 | 01-JUL-14:09 | 1931.10 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1126.80 | 15-JUL-15:00 | 1634.45 | 08-JUL-11:10 |
August | 2699.95 | 05-AUG-14:09 | 1931.10 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1058.40 | 08-AUG-16:00 | 1936.67 | 17-AUG-14:00 |
September | 2699.95 | 02-SEP-14:09 | 1931.10 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 343.19 | 01-SEP-15:00 | 2317.57 | 27-SEP-11:10 |
October | 2699.95 | 07-OCT-14:09 | 1931.10 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 3839.29 | 29-OCT-17:00 |
November | 2699.95 | 04-NOV-14:09 | 1931.10 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 6607.53 | 25-NOV-17:00 |
December | 2699.95 | 02-DEC-15:09 | 1931.10 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 9445.98 | 24-DEC-12:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 2699.95 | 1931.10 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1634.45 | |||||
Maximum of Months | 2699.95 | 1931.10 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1706.48 | 9736.58 |
Report: PeakSpaceGainsMonthly
For: SMSTORE8
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2699.95 | 07-JAN-15:09 | 1931.10 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 10383.07 | 04-JAN-12:10 |
February | 2699.95 | 04-FEB-15:09 | 1931.10 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 8455.57 | 13-FEB-12:10 |
March | 2699.95 | 04-MAR-15:09 | 1931.10 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 6926.90 | 15-MAR-11:10 |
April | 2699.95 | 01-APR-14:09 | 1931.10 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 484.25 | 23-APR-16:00 | 4861.14 | 04-APR-17:00 |
May | 2699.95 | 06-MAY-14:09 | 1931.10 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 822.97 | 25-MAY-17:00 | 2474.17 | 01-MAY-11:10 |
June | 2699.95 | 03-JUN-14:09 | 1931.10 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1795.46 | 29-JUN-16:00 | 1678.45 | 09-JUN-11:10 |
July | 2699.95 | 01-JUL-14:09 | 1931.10 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1203.14 | 15-JUL-15:00 | 1583.16 | 08-JUL-11:10 |
August | 2699.95 | 05-AUG-14:09 | 1931.10 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1117.52 | 08-AUG-16:00 | 1990.17 | 17-AUG-14:00 |
September | 2699.95 | 02-SEP-14:09 | 1931.10 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 352.91 | 01-SEP-15:00 | 2396.99 | 27-SEP-11:10 |
October | 2699.95 | 07-OCT-14:09 | 1931.10 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 4035.44 | 31-OCT-17:00 |
November | 2699.95 | 04-NOV-14:09 | 1931.10 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 6810.79 | 25-NOV-12:10 |
December | 2699.95 | 02-DEC-15:09 | 1931.10 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 9905.32 | 24-DEC-12:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 2699.95 | 1931.10 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1583.16 | |||||
Maximum of Months | 2699.95 | 1931.10 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1795.46 | 10383.07 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LGSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 23872.43 | 06-JAN-00:01 | 3375.03 | 2800.56 | 7490.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 337.34 |
February | 20041.32 | 25-FEB-00:01 | 3037.53 | 25206.67 | 6741.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 410.82 |
March | 5982.68 | 15-MAR-08:04 | 2700.03 | 22405.92 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2501.84 |
April | 8760.87 | 23-APR-16:03 | 12150.11 | 15964.28 | 4044.77 | 0.00 | 0.00 | 0.00 | 0.00 | 809.19 | 0.00 |
May | 32018.87 | 26-MAY-08:62 | 1687.52 | 14003.70 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 177.71 |
June | 31644.43 | 26-JUN-08:62 | 1687.52 | 14003.70 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 294.08 |
July | 36316.80 | 01-JUL-08:62 | 1687.52 | 14003.70 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 244.29 |
August | 34222.60 | 10-AUG-08:62 | 2025.02 | 16804.44 | 4494.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 334.64 |
September | 30497.98 | 01-SEP-08:62 | 1687.52 | 14003.70 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 300.06 |
October | 8396.72 | 22-OCT-17:03 | 24300.23 | 31928.55 | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 386.47 |
November | 5386.56 | 25-NOV-09:04 | 2700.03 | 22405.92 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2240.72 |
December | 18029.06 | 02-DEC-00:33 | 1350.01 | 11202.96 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 436.56 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 5386.56 | 1350.01 | 2800.56 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 36316.80 | 24300.23 | 31928.55 | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 809.19 | 2501.84 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 9753.03 | 27-JAN-20:31 | 7087.36 | 20527.98 | 4718.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 9047.36 | 10-FEB-09:04 | 1349.97 | 12347.66 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1083.88 |
March | 8721.11 | 18-MAR-08:04 | 1349.97 | 12347.66 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 898.85 |
April | 12875.25 | 23-APR-20:40 | 3037.44 | 8797.70 | 2022.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.05 |
May | 17405.30 | 26-MAY-08:62 | 843.73 | 7717.28 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 93.74 |
June | 22196.06 | 07-JUN-08:62 | 843.73 | 7717.28 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 99.42 |
July | 19557.49 | 01-JUL-08:62 | 843.73 | 7717.28 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 142.03 |
August | 18893.53 | 10-AUG-08:62 | 1012.48 | 9260.74 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 188.35 |
September | 17559.42 | 02-SEP-08:62 | 674.99 | 6173.83 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 205.43 |
October | 12903.27 | 22-OCT-17:35 | 4049.92 | 5865.14 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 212.84 |
November | 8152.74 | 29-NOV-09:04 | 1349.97 | 12347.66 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 931.20 |
December | 8791.37 | 08-DEC-20:31 | 7087.36 | 20527.98 | 4718.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80.98 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 8152.74 | 674.99 | 5865.14 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 22196.06 | 7087.36 | 20527.98 | 4718.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1083.88 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 8030.91 | 18-JAN-08:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 914.67 |
February | 8454.17 | 11-FEB-08:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 863.03 |
March | 8953.48 | 23-MAR-07:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 927.08 |
April | 7521.45 | 05-APR-07:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 767.46 |
May | 18026.09 | 26-MAY-07:02 | 1012.48 | 8208.08 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110.30 |
June | 17584.38 | 22-JUN-07:02 | 843.73 | 6840.07 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 147.04 |
July | 21090.73 | 17-JUL-07:02 | 843.73 | 6840.07 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 231.99 |
August | 20527.59 | 07-AUG-07:02 | 843.73 | 6840.07 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 267.32 |
September | 22051.80 | 02-SEP-07:02 | 843.73 | 6840.07 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 235.78 |
October | 6046.26 | 30-OCT-07:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 779.40 |
November | 7228.59 | 23-NOV-09:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 835.48 |
December | 7874.56 | 15-DEC-08:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 896.24 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 6046.26 | 843.73 | 6840.07 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110.30 | |
Maximum of Months | 22051.80 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 927.08 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 9347.97 | 07-JAN-08:04 | 1518.72 | 12312.12 | 3370.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1187.11 |
February | 8435.17 | 11-FEB-08:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 862.22 |
March | 8934.84 | 23-MAR-07:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 926.27 |
April | 7578.92 | 05-APR-07:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 768.97 |
May | 18109.85 | 26-MAY-07:02 | 1012.48 | 8208.08 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110.66 |
June | 17637.66 | 22-JUN-07:02 | 843.73 | 6840.07 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 146.88 |
July | 21177.63 | 17-JUL-07:02 | 843.73 | 6840.07 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 232.30 |
August | 20599.78 | 07-AUG-07:02 | 843.73 | 6840.07 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 267.43 |
September | 22129.55 | 02-SEP-07:02 | 843.73 | 6840.07 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 235.87 |
October | 6857.71 | 30-OCT-07:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 782.90 |
November | 7264.06 | 23-NOV-09:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 836.54 |
December | 7867.48 | 15-DEC-08:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 895.92 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 6857.71 | 843.73 | 6840.07 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110.66 | |
Maximum of Months | 22129.55 | 1518.72 | 12312.12 | 3370.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1187.11 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 7246.29 | 22-JAN-09:04 | 1687.47 | 13680.14 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 969.63 |
February | 7818.86 | 28-FEB-08:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 836.03 |
March | 7749.79 | 11-MAR-08:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 854.47 |
April | 7524.29 | 05-APR-07:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 766.37 |
May | 17894.39 | 26-MAY-07:02 | 1012.48 | 8208.08 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 107.86 |
June | 17434.88 | 22-JUN-07:02 | 843.73 | 6840.07 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 144.11 |
July | 20990.83 | 17-JUL-07:02 | 843.73 | 6840.07 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 230.13 |
August | 20419.90 | 07-AUG-07:02 | 843.73 | 6840.07 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 265.09 |
September | 21931.39 | 02-SEP-07:02 | 843.73 | 6840.07 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 233.81 |
October | 6931.00 | 30-OCT-07:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 785.00 |
November | 7269.24 | 23-NOV-09:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 836.67 |
December | 6773.24 | 07-DEC-08:04 | 1349.97 | 10944.11 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 745.47 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 6773.24 | 843.73 | 6840.07 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 107.86 | |
Maximum of Months | 21931.39 | 1687.47 | 13680.14 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 969.63 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LGSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 6012.33 | 08-JAN-10:04 | 5940.06 | 15774.71 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2320.73 |
February | 6172.67 | 24-FEB-09:04 | 5940.06 | 15774.71 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2428.74 |
March | 6064.78 | 15-MAR-08:04 | 5940.06 | 15774.71 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2244.99 |
April | 6644.79 | 23-APR-15:00 | 4657.54 | 3746.51 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 487.83 | 0.00 |
May | 31961.92 | 26-MAY-08:62 | 3712.53 | 9859.20 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 167.14 |
June | 32231.74 | 18-JUN-09:02 | 2970.03 | 7887.36 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 99.07 |
July | 36101.77 | 01-JUL-08:62 | 3712.53 | 9859.20 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 255.97 |
August | 34183.84 | 10-AUG-08:62 | 4455.04 | 11831.03 | 4494.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 332.81 |
September | 30914.11 | 02-SEP-08:62 | 2970.03 | 7887.36 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 372.78 |
October | 7316.53 | 22-OCT-14:10 | 4657.54 | 3746.51 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1293.74 |
November | 5428.49 | 25-NOV-09:04 | 5940.06 | 15774.71 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1987.00 |
December | 6042.04 | 01-DEC-09:04 | 5940.06 | 15774.71 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2296.27 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 5428.49 | 2970.03 | 3746.51 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 36101.77 | 5940.06 | 15774.71 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 487.83 | 2428.74 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 6821.76 | 20-JAN-09:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 832.78 |
February | 7144.07 | 28-FEB-09:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 811.22 |
March | 7579.16 | 23-MAR-08:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 847.37 |
April | 6892.46 | 05-APR-08:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 769.92 |
May | 16353.64 | 26-MAY-08:62 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.20 |
June | 16053.76 | 26-JUN-08:62 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 146.41 |
July | 18467.40 | 06-JUL-08:62 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 165.88 |
August | 17432.27 | 10-AUG-08:62 | 2227.46 | 6098.20 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 183.32 |
September | 15422.04 | 01-SEP-08:62 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 149.83 |
October | 6420.11 | 30-OCT-08:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 717.56 |
November | 7255.93 | 23-NOV-10:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 833.11 |
December | 6727.70 | 07-DEC-09:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 736.12 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 6420.11 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.20 | |
Maximum of Months | 18467.40 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 847.37 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 6818.03 | 20-JAN-09:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 832.36 |
February | 7131.25 | 28-FEB-09:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 810.37 |
March | 7265.62 | 17-MAR-08:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 823.60 |
April | 6878.57 | 05-APR-08:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 769.02 |
May | 16184.52 | 26-MAY-08:62 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87.41 |
June | 15906.39 | 26-JUN-08:62 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 144.86 |
July | 18314.12 | 06-JUL-08:62 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 164.48 |
August | 17294.51 | 10-AUG-08:62 | 2227.46 | 6098.20 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 182.30 |
September | 15295.65 | 01-SEP-08:62 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 148.74 |
October | 6419.41 | 30-OCT-08:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 717.40 |
November | 7235.30 | 23-NOV-10:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 831.83 |
December | 6716.33 | 07-DEC-09:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 735.37 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 6419.41 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87.41 | |
Maximum of Months | 18314.12 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 832.36 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 6767.54 | 20-JAN-09:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 829.34 |
February | 6709.25 | 23-FEB-09:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 760.58 |
March | 7025.90 | 11-MAR-09:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 806.22 |
April | 6827.05 | 05-APR-08:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 766.16 |
May | 15852.95 | 26-MAY-08:62 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 81.17 |
June | 15598.95 | 26-JUN-08:62 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 138.70 |
July | 18072.60 | 01-JUL-08:62 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 135.61 |
August | 17047.68 | 10-AUG-08:62 | 2227.46 | 6098.20 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 178.51 |
September | 15052.87 | 01-SEP-08:62 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 144.50 |
October | 6341.93 | 30-OCT-08:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 713.24 |
November | 7180.92 | 23-NOV-10:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 828.73 |
December | 6683.00 | 07-DEC-09:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 733.49 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 6341.93 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 81.17 | |
Maximum of Months | 18072.60 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 829.34 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE8
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 6660.85 | 20-JAN-09:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1074.72 |
February | 6997.72 | 28-FEB-09:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 950.53 |
March | 7133.00 | 17-MAR-08:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 972.85 |
April | 6739.57 | 05-APR-08:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 901.36 |
May | 6646.10 | 26-MAY-08:62 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 94.59 |
June | 16879.96 | 27-JUN-08:62 | 2227.46 | 6098.20 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.82 |
July | 17711.41 | 24-JUL-08:61 | 2598.70 | 7114.56 | 2621.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.03 |
August | 16238.67 | 09-AUG-08:62 | 2227.46 | 6098.20 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87.52 |
September | 11929.73 | 01-SEP-08:62 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 169.05 |
October | 6200.06 | 30-OCT-08:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 844.21 |
November | 7070.79 | 23-NOV-10:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1021.91 |
December | 6580.58 | 07-DEC-09:04 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 842.17 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 6200.06 | 1856.21 | 5081.83 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.82 | |
Maximum of Months | 17711.41 | 2969.94 | 8130.93 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1074.72 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
January | 0.784290E+11 | 63775.02 | 03-JAN-16:40 | 0.249071E+12 | 371004.11 | 06-JAN-09:09 |
February | 0.688944E+11 | 60173.66 | 02-FEB-17:10 | 0.160235E+12 | 331294.12 | 14-FEB-09:09 |
March | 0.748495E+11 | 58610.23 | 06-MAR-18:40 | 0.130520E+12 | 262269.33 | 15-MAR-08:09 |
April | 0.690270E+11 | 62132.01 | 23-APR-14:00 | 0.438227E+11 | 186441.60 | 05-APR-08:09 |
May | 0.746110E+11 | 73760.77 | 25-MAY-15:50 | 0.275928E+10 | 110134.93 | 01-MAY-08:09 |
June | 0.797472E+11 | 97695.45 | 29-JUN-16:30 | 8883990.83 | 1179.33 | 11-JUN-09:30 |
July | 0.882702E+11 | 90303.30 | 15-JUL-14:09 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 0.845580E+11 | 85902.97 | 08-AUG-15:09 | 733822.89 | 446.17 | 18-AUG-08:30 |
September | 0.708096E+11 | 74127.33 | 01-SEP-13:39 | 0.153242E+10 | 24817.78 | 28-SEP-08:09 |
October | 0.730647E+11 | 59492.77 | 11-OCT-18:40 | 0.328648E+11 | 164705.86 | 30-OCT-08:09 |
November | 0.731060E+11 | 60082.36 | 08-NOV-17:40 | 0.978959E+11 | 244521.33 | 25-NOV-09:09 |
December | 0.781856E+11 | 62555.01 | 12-DEC-17:19 | 0.227439E+12 | 337924.85 | 20-DEC-09:09 |
Annual Sum or Average | 0.913552E+12 | 0.946150E+12 | ||||
Minimum of Months | 0.688944E+11 | 58610.23 | 0.00 | 0.00 | ||
Maximum of Months | 0.882702E+11 | 97695.45 | 0.249071E+12 | 371004.11 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.373403E+11 | 0.114147E+11 | 0.108804E+11 | 0.00 | 0.118709E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101044E+10 | 0.591220E+10 | 0.00 |
February | 0.337970E+11 | 0.923774E+10 | 0.985143E+10 | 0.00 | 0.970960E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.914740E+09 | 0.538391E+10 | 0.00 |
March | 0.378801E+11 | 0.877223E+10 | 0.110560E+11 | 0.00 | 0.101245E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102287E+10 | 0.599382E+10 | 0.00 |
April | 0.362171E+11 | 0.702557E+10 | 0.105544E+11 | 0.00 | 0.840820E+10 | 0.00 | 0.00 | 0.216677E+09 | 0.00 | 0.00 | 0.926547E+09 | 0.567848E+10 | 0.00 |
May | 0.376032E+11 | 0.606215E+10 | 0.109629E+11 | 0.00 | 0.818000E+10 | 0.00 | 0.00 | 0.542033E+10 | 0.00 | 0.00 | 0.639890E+09 | 0.574250E+10 | 0.00 |
June | 0.366114E+11 | 0.525677E+10 | 0.106855E+11 | 0.00 | 0.806407E+10 | 0.00 | 0.00 | 0.132297E+11 | 0.00 | 0.00 | 0.433131E+09 | 0.546658E+10 | 0.00 |
July | 0.372230E+11 | 0.568258E+10 | 0.108424E+11 | 0.00 | 0.815442E+10 | 0.00 | 0.00 | 0.203827E+11 | 0.00 | 0.00 | 0.481631E+09 | 0.550350E+10 | 0.00 |
August | 0.378660E+11 | 0.667834E+10 | 0.110491E+11 | 0.00 | 0.825522E+10 | 0.00 | 0.00 | 0.148711E+11 | 0.00 | 0.00 | 0.323559E+09 | 0.551464E+10 | 0.00 |
September | 0.362312E+11 | 0.784848E+10 | 0.105613E+11 | 0.00 | 0.787624E+10 | 0.00 | 0.00 | 0.245521E+10 | 0.00 | 0.00 | 0.506393E+09 | 0.533082E+10 | 0.00 |
October | 0.373403E+11 | 0.962714E+10 | 0.108804E+11 | 0.00 | 0.849340E+10 | 0.00 | 0.00 | 0.202296E+09 | 0.00 | 0.00 | 0.925822E+09 | 0.559533E+10 | 0.00 |
November | 0.361749E+11 | 0.106464E+11 | 0.105443E+11 | 0.00 | 0.922963E+10 | 0.00 | 0.00 | 146318.85 | 0.00 | 0.00 | 0.978125E+09 | 0.553259E+10 | 0.00 |
December | 0.372370E+11 | 0.117667E+11 | 0.108529E+11 | 0.00 | 0.114944E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101044E+10 | 0.582413E+10 | 0.00 |
Annual Sum or Average | 0.441522E+12 | 0.100019E+12 | 0.128721E+12 | 0.00 | 0.109861E+12 | 0.00 | 0.00 | 0.567783E+11 | 0.00 | 0.00 | 0.917358E+10 | 0.674785E+11 | 0.00 |
Minimum of Months | 0.337970E+11 | 0.525677E+10 | 0.985143E+10 | 0.00 | 0.787624E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323559E+09 | 0.533082E+10 | 0.00 |
Maximum of Months | 0.378801E+11 | 0.117667E+11 | 0.110560E+11 | 0.00 | 0.118709E+11 | 0.00 | 0.00 | 0.203827E+11 | 0.00 | 0.00 | 0.102287E+10 | 0.599382E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
January | 0.00 | 0.00 | 0.249071E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.160235E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.130520E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.438227E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.275928E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 8883990.83 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 733822.89 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.153242E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.328648E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.978959E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.227439E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.946150E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.249071E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 27522.57 | 01-JAN-11:09 | 7619.51 | 01-JAN-06:10 | 8089.53 | 01-JAN-11:09 | 0.00 | 11214.04 | 06-JAN-09:09 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 27522.57 | 01-FEB-10:09 | 7619.51 | 01-FEB-06:10 | 8089.53 | 01-FEB-10:09 | 0.00 | 10603.51 | 14-FEB-09:09 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 27522.57 | 01-MAR-10:09 | 7619.51 | 01-MAR-06:10 | 8089.53 | 01-MAR-10:09 | 0.00 | 9561.86 | 15-MAR-08:09 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 27522.57 | 01-APR-09:09 | 7619.51 | 01-APR-05:10 | 8089.53 | 01-APR-09:09 | 0.00 | 8389.53 | 05-APR-08:09 | 0.00 | 0.00 | 01-APR-00:10 |
May | 27522.57 | 01-MAY-09:09 | 7619.51 | 01-MAY-19:30 | 8089.53 | 01-MAY-09:09 | 0.00 | 7211.96 | 01-MAY-08:09 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 27522.57 | 01-JUN-09:09 | 7619.51 | 01-JUN-19:00 | 8089.53 | 01-JUN-09:09 | 0.00 | 8258.77 | 30-JUN-12:00 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 27522.57 | 01-JUL-09:09 | 7619.51 | 01-JUL-20:19 | 8089.53 | 01-JUL-09:09 | 0.00 | 7791.68 | 15-JUL-13:00 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 27522.57 | 01-AUG-09:09 | 7619.51 | 01-AUG-19:49 | 8089.53 | 01-AUG-09:09 | 0.00 | 7257.26 | 09-AUG-08:09 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 27522.57 | 01-SEP-09:09 | 7619.51 | 01-SEP-05:10 | 8089.53 | 01-SEP-09:09 | 0.00 | 6615.28 | 01-SEP-08:09 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 27522.57 | 01-OCT-10:09 | 7619.51 | 01-OCT-05:10 | 8089.53 | 01-OCT-10:09 | 0.00 | 8054.56 | 30-OCT-08:09 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 27522.57 | 01-NOV-09:09 | 7619.51 | 01-NOV-05:10 | 8089.53 | 01-NOV-09:09 | 0.00 | 9287.06 | 25-NOV-09:09 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 27522.57 | 01-DEC-10:09 | 7619.51 | 01-DEC-06:10 | 8089.53 | 01-DEC-10:09 | 0.00 | 10705.44 | 20-DEC-09:09 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||||
Minimum of Months | 27522.57 | 7619.51 | 8089.53 | 0.00 | 6615.28 | 0.00 | 0.00 | |||||
Maximum of Months | 27522.57 | 7619.51 | 8089.53 | 0.00 | 11214.04 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY {Maximum} [W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 690.47 | 30-JAN-19:40 | 11897.35 | 03-JAN-14:09 | 0.00 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 690.47 | 03-FEB-18:10 | 10147.67 | 01-FEB-14:30 | 0.00 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 690.47 | 12-MAR-10:00 | 11902.60 | 31-MAR-13:39 | 0.00 |
April | 14567.35 | 23-APR-15:00 | 0.00 | 0.00 | 690.47 | 01-APR-12:39 | 11218.93 | 10-APR-11:50 | 0.00 |
May | 26746.95 | 25-MAY-16:10 | 0.00 | 0.00 | 690.47 | 01-MAY-09:00 | 9671.04 | 21-MAY-16:10 | 0.00 |
June | 44729.40 | 29-JUN-16:10 | 0.00 | 0.00 | 690.47 | 17-JUN-17:10 | 11872.43 | 14-JUN-12:20 | 0.00 |
July | 41076.07 | 15-JUL-13:00 | 0.00 | 0.00 | 690.47 | 03-JUL-19:10 | 11678.89 | 29-JUL-13:39 | 0.00 |
August | 36886.92 | 08-AUG-14:00 | 0.00 | 0.00 | 690.47 | 08-AUG-19:10 | 9698.16 | 04-AUG-14:20 | 0.00 |
September | 25294.98 | 01-SEP-14:20 | 0.00 | 0.00 | 690.47 | 06-SEP-08:09 | 9692.73 | 23-SEP-13:39 | 0.00 |
October | 7171.65 | 19-OCT-14:00 | 0.00 | 0.00 | 690.47 | 02-OCT-08:09 | 13283.29 | 09-OCT-16:49 | 0.00 |
November | 157.40 | 01-NOV-20:40 | 0.00 | 0.00 | 690.47 | 14-NOV-19:30 | 9743.90 | 08-NOV-13:30 | 0.00 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 690.47 | 01-DEC-09:20 | 10127.17 | 12-DEC-17:19 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 690.47 | 9671.04 | 0.00 | |||
Maximum of Months | 44729.40 | 0.00 | 0.00 | 690.47 | 13283.29 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 63775.02 | 03-JAN-16:40 | 27522.57 | 8089.53 | 7619.51 | 0.00 | 9223.82 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 60173.66 | 02-FEB-17:10 | 27522.57 | 8089.53 | 7619.51 | 0.00 | 8652.53 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 58610.23 | 06-MAR-18:40 | 27522.57 | 8089.53 | 7619.51 | 0.00 | 7132.59 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 62132.01 | 23-APR-14:00 | 27522.57 | 8089.53 | 0.00 | 0.00 | 5509.67 | 0.00 | 0.00 | 14414.12 | 0.00 |
May | 73760.77 | 25-MAY-15:50 | 27522.57 | 8089.53 | 0.00 | 0.00 | 5509.67 | 0.00 | 0.00 | 26028.09 | 0.00 |
June | 97695.45 | 29-JUN-16:30 | 27522.57 | 8089.53 | 0.00 | 0.00 | 7988.17 | 0.00 | 0.00 | 43714.43 | 0.00 |
July | 90303.30 | 15-JUL-14:09 | 27522.57 | 8089.53 | 0.00 | 0.00 | 7724.76 | 0.00 | 0.00 | 40815.21 | 0.00 |
August | 85902.97 | 08-AUG-15:09 | 27522.57 | 8089.53 | 0.00 | 0.00 | 6664.19 | 0.00 | 0.00 | 36304.23 | 0.00 |
September | 74127.33 | 01-SEP-13:39 | 27522.57 | 8089.53 | 0.00 | 0.00 | 5509.67 | 0.00 | 0.00 | 24761.20 | 0.00 |
October | 59492.77 | 11-OCT-18:40 | 27522.57 | 8089.53 | 7619.51 | 0.00 | 5888.49 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 60082.36 | 08-NOV-17:40 | 27522.57 | 8089.53 | 7619.51 | 0.00 | 6750.07 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 62555.01 | 12-DEC-17:19 | 27522.57 | 8089.53 | 7619.51 | 0.00 | 8505.75 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 58610.23 | 27522.57 | 8089.53 | 0.00 | 0.00 | 5509.67 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 97695.45 | 27522.57 | 8089.53 | 7619.51 | 0.00 | 9223.82 | 0.00 | 0.00 | 43714.43 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | |
January | 0.00 | 0.00 | 371004.11 | 06-JAN-09:09 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 331294.12 | 14-FEB-09:09 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 262269.33 | 15-MAR-08:09 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 186441.60 | 05-APR-08:09 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 110134.93 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 1179.33 | 11-JUN-09:30 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 446.17 | 18-AUG-08:30 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 24817.78 | 28-SEP-08:09 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 164705.86 | 30-OCT-08:09 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 244521.33 | 25-NOV-09:09 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 337924.85 | 20-DEC-09:09 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 371004.11 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LGSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 3.67 | 19.21 | 0.00 | 19.21 | 0.00 | 19.21 | 0.00 | 19.21 |
February | 2.00 | 19.32 | 0.00 | 19.32 | 0.00 | 19.32 | 0.00 | 19.32 |
March | 1.83 | 20.33 | 0.00 | 20.33 | 0.00 | 20.33 | 0.00 | 20.33 |
April | 0.67 | 20.49 | 0.00 | 20.49 | 0.00 | 20.49 | 0.00 | 20.49 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.67 | 20.41 | 0.00 | 20.41 | 0.00 | 20.41 | 0.00 | 20.41 |
December | 2.83 | 19.55 | 0.00 | 19.55 | 0.00 | 19.55 | 0.00 | 19.55 |
Annual Sum or Average | 11.67 | 19.63 | 0.00 | 19.63 | 0.00 | 19.63 | 0.00 | 19.63 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 3.67 | 20.49 | 0.00 | 20.49 | 0.00 | 20.49 | 0.00 | 20.49 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 2.00 | 20.35 | 0.00 | 20.35 | 0.00 | 20.35 | 0.00 | 20.35 |
February | 1.33 | 20.43 | 0.00 | 20.43 | 0.00 | 20.43 | 0.00 | 20.43 |
March | 0.83 | 20.51 | 0.00 | 20.51 | 0.00 | 20.51 | 0.00 | 20.51 |
April | 0.17 | 20.43 | 0.00 | 20.43 | 0.00 | 20.43 | 0.00 | 20.43 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.33 | 20.44 | 0.00 | 20.44 | 0.00 | 20.44 | 0.00 | 20.44 |
December | 1.67 | 20.35 | 0.00 | 20.35 | 0.00 | 20.35 | 0.00 | 20.35 |
Annual Sum or Average | 6.33 | 20.40 | 0.00 | 20.40 | 0.00 | 20.40 | 0.00 | 20.40 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2.00 | 20.51 | 0.00 | 20.51 | 0.00 | 20.51 | 0.00 | 20.51 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LGSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.33 | 14.95 | 0.00 | 14.95 | 0.00 | 14.95 | 0.00 | 14.95 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.47 | 0.17 | 24.47 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.67 | 14.89 | 0.00 | 14.89 | 0.00 | 14.89 | 0.00 | 14.89 |
Annual Sum or Average | 1.00 | 14.91 | 0.00 | 14.91 | 0.17 | 16.28 | 0.17 | 17.30 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.67 | 14.95 | 0.00 | 14.95 | 0.17 | 24.47 | 0.17 | 24.47 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.17 | 14.91 | 0.00 | 14.91 | 0.00 | 14.91 | 0.00 | 14.91 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.50 | 14.87 | 0.00 | 14.87 | 0.00 | 14.87 | 0.00 | 14.87 |
Annual Sum or Average | 0.67 | 14.88 | 0.00 | 14.88 | 0.00 | 14.88 | 0.00 | 14.88 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.50 | 14.91 | 0.00 | 14.91 | 0.00 | 14.91 | 0.00 | 14.91 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.17 | 14.91 | 0.00 | 14.91 | 0.00 | 14.91 | 0.00 | 14.91 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.67 | 14.88 | 0.00 | 14.88 | 0.00 | 14.88 | 0.00 | 14.88 |
Annual Sum or Average | 0.83 | 14.88 | 0.00 | 14.88 | 0.00 | 14.88 | 0.00 | 14.88 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.67 | 14.91 | 0.00 | 14.91 | 0.00 | 14.91 | 0.00 | 14.91 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.33 | 14.95 | 0.00 | 14.95 | 0.00 | 14.95 | 0.00 | 14.95 |
February | 0.33 | 14.99 | 0.00 | 14.99 | 0.00 | 14.99 | 0.00 | 14.99 |
March | 0.17 | 14.98 | 0.00 | 14.98 | 0.00 | 14.98 | 0.00 | 14.98 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 1.50 | 14.91 | 0.00 | 14.91 | 0.00 | 14.91 | 0.00 | 14.91 |
Annual Sum or Average | 3.33 | 14.94 | 0.00 | 14.94 | 0.00 | 14.94 | 0.00 | 14.94 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1.50 | 14.99 | 0.00 | 14.99 | 0.00 | 14.99 | 0.00 | 14.99 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE8
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 43.33 | 14.70 | 0.00 | 14.70 | 0.00 | 14.70 | 0.00 | 14.70 |
February | 30.33 | 14.79 | 0.00 | 14.79 | 0.00 | 14.79 | 0.00 | 14.79 |
March | 14.17 | 14.83 | 0.00 | 14.83 | 0.00 | 14.83 | 0.00 | 14.83 |
April | 1.00 | 14.96 | 0.00 | 14.96 | 0.00 | 14.96 | 0.00 | 14.96 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 2.50 | 14.93 | 0.00 | 14.93 | 0.00 | 14.93 | 0.00 | 14.93 |
December | 39.33 | 14.74 | 0.00 | 14.74 | 0.00 | 14.74 | 0.00 | 14.74 |
Annual Sum or Average | 130.67 | 14.76 | 0.00 | 14.76 | 0.00 | 14.76 | 0.00 | 14.76 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 43.33 | 14.96 | 0.00 | 14.96 | 0.00 | 14.96 | 0.00 | 14.96 |
Report: ComfortReportSimple55Monthly
For: LGSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 496.00 | 20.91 | 496.00 | 20.91 | 496.00 | 20.91 |
February | 448.00 | 20.93 | 419.83 | 20.92 | 419.83 | 20.92 |
March | 497.00 | 21.03 | 400.83 | 20.98 | 400.83 | 20.96 |
April | 464.83 | 21.91 | 149.83 | 21.68 | 143.67 | 21.52 |
May | 249.00 | 23.32 | 108.67 | 23.45 | 5.17 | 23.41 |
June | 132.50 | 23.88 | 310.67 | 23.91 | 79.67 | 23.91 |
July | 78.33 | 23.91 | 466.83 | 23.92 | 75.50 | 23.92 |
August | 49.00 | 23.98 | 433.17 | 23.93 | 44.67 | 23.93 |
September | 143.17 | 23.39 | 136.83 | 23.64 | 8.50 | 23.64 |
October | 419.50 | 22.04 | 41.67 | 21.96 | 35.83 | 21.87 |
November | 480.00 | 21.09 | 323.67 | 21.02 | 323.67 | 20.99 |
December | 496.00 | 20.94 | 496.00 | 20.94 | 496.00 | 20.94 |
Annual Sum or Average | 3953.33 | 21.63 | 3784.00 | 21.85 | 2529.33 | 21.68 |
Minimum of Months | 49.00 | 20.91 | 41.67 | 20.91 | 5.17 | 20.91 |
Maximum of Months | 497.00 | 23.98 | 496.00 | 23.93 | 496.00 | 23.93 |
Report: ComfortReportSimple55Monthly
For: SMSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 496.00 | 20.98 | 478.17 | 20.97 | 478.17 | 20.97 |
February | 448.00 | 21.05 | 346.17 | 21.01 | 346.17 | 20.99 |
March | 497.00 | 21.19 | 286.33 | 21.10 | 286.33 | 21.06 |
April | 463.67 | 21.95 | 62.33 | 21.85 | 56.33 | 21.74 |
May | 259.67 | 23.00 | 102.83 | 23.23 | 2.17 | 23.22 |
June | 111.50 | 23.70 | 299.50 | 23.86 | 62.67 | 23.86 |
July | 51.33 | 23.89 | 466.00 | 23.91 | 49.17 | 23.91 |
August | 33.17 | 23.68 | 437.00 | 23.90 | 24.50 | 23.90 |
September | 156.00 | 22.73 | 124.50 | 23.24 | 6.33 | 23.26 |
October | 436.17 | 21.93 | 11.00 | 21.94 | 5.00 | 21.93 |
November | 480.00 | 21.31 | 179.17 | 21.20 | 179.17 | 21.14 |
December | 496.00 | 21.00 | 473.33 | 20.99 | 473.33 | 20.98 |
Annual Sum or Average | 3928.50 | 21.62 | 3266.33 | 21.91 | 1969.33 | 21.75 |
Minimum of Months | 33.17 | 20.98 | 11.00 | 20.97 | 2.17 | 20.97 |
Maximum of Months | 497.00 | 23.89 | 478.17 | 23.91 | 478.17 | 23.91 |
Report: ComfortReportSimple55Monthly
For: SMSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 371.00 | 21.11 | 371.00 | 21.11 | 371.00 | 21.11 |
February | 336.00 | 21.11 | 298.50 | 21.11 | 298.50 | 21.11 |
March | 379.00 | 21.11 | 265.33 | 21.11 | 265.33 | 21.11 |
April | 353.67 | 21.52 | 89.50 | 21.46 | 87.17 | 21.40 |
May | 217.50 | 22.51 | 91.50 | 22.92 | 4.50 | 22.89 |
June | 120.00 | 23.65 | 223.17 | 23.89 | 66.67 | 23.92 |
July | 63.00 | 24.12 | 347.83 | 24.04 | 60.17 | 24.05 |
August | 45.17 | 23.71 | 334.00 | 23.96 | 31.33 | 23.97 |
September | 163.17 | 22.24 | 82.17 | 22.81 | 9.67 | 22.86 |
October | 341.00 | 21.37 | 26.33 | 21.39 | 21.33 | 21.37 |
November | 360.00 | 21.14 | 202.17 | 21.13 | 202.17 | 21.12 |
December | 369.00 | 21.11 | 369.00 | 21.11 | 369.00 | 21.11 |
Annual Sum or Average | 3118.50 | 21.54 | 2700.50 | 21.88 | 1786.83 | 21.76 |
Minimum of Months | 45.17 | 21.11 | 26.33 | 21.11 | 4.50 | 21.11 |
Maximum of Months | 379.00 | 24.12 | 371.00 | 24.04 | 371.00 | 24.05 |
Report: ComfortReportSimple55Monthly
For: SMSTORE3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 371.00 | 21.11 | 371.00 | 21.11 | 371.00 | 21.11 |
February | 336.00 | 21.11 | 305.83 | 21.11 | 305.83 | 21.11 |
March | 379.00 | 21.11 | 273.67 | 21.11 | 273.67 | 21.11 |
April | 355.00 | 21.50 | 97.67 | 21.42 | 96.67 | 21.37 |
May | 222.83 | 22.46 | 90.67 | 22.87 | 5.17 | 22.84 |
June | 123.50 | 23.61 | 220.17 | 23.87 | 66.83 | 23.90 |
July | 63.50 | 24.11 | 346.83 | 24.04 | 60.17 | 24.05 |
August | 46.50 | 23.70 | 333.83 | 23.96 | 31.83 | 23.97 |
September | 173.83 | 22.25 | 80.33 | 22.78 | 10.67 | 22.83 |
October | 343.50 | 21.35 | 31.67 | 21.36 | 27.50 | 21.34 |
November | 360.00 | 21.13 | 216.83 | 21.12 | 216.83 | 21.12 |
December | 369.00 | 21.11 | 369.00 | 21.11 | 369.00 | 21.11 |
Annual Sum or Average | 3143.67 | 21.54 | 2737.50 | 21.87 | 1835.17 | 21.75 |
Minimum of Months | 46.50 | 21.11 | 31.67 | 21.11 | 5.17 | 21.11 |
Maximum of Months | 379.00 | 24.11 | 371.00 | 24.04 | 371.00 | 24.05 |
Report: ComfortReportSimple55Monthly
For: SMSTORE4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 371.00 | 21.11 | 371.00 | 21.11 | 371.00 | 21.11 |
February | 336.00 | 21.11 | 312.00 | 21.11 | 312.00 | 21.11 |
March | 379.00 | 21.11 | 288.33 | 21.11 | 288.33 | 21.11 |
April | 355.00 | 21.48 | 109.50 | 21.40 | 108.50 | 21.35 |
May | 226.17 | 22.45 | 88.50 | 22.84 | 6.00 | 22.81 |
June | 127.00 | 23.59 | 215.17 | 23.86 | 68.33 | 23.89 |
July | 66.17 | 24.09 | 343.83 | 24.03 | 62.00 | 24.05 |
August | 49.17 | 23.68 | 332.00 | 23.95 | 33.50 | 23.96 |
September | 178.33 | 22.26 | 78.83 | 22.78 | 11.83 | 22.83 |
October | 344.67 | 21.36 | 38.50 | 21.36 | 34.67 | 21.34 |
November | 360.00 | 21.13 | 233.00 | 21.12 | 233.00 | 21.12 |
December | 369.00 | 21.11 | 369.00 | 21.11 | 369.00 | 21.11 |
Annual Sum or Average | 3161.50 | 21.54 | 2779.67 | 21.85 | 1898.17 | 21.74 |
Minimum of Months | 49.17 | 21.11 | 38.50 | 21.11 | 6.00 | 21.11 |
Maximum of Months | 379.00 | 24.09 | 371.00 | 24.03 | 371.00 | 24.05 |
Report: ComfortReportSimple55Monthly
For: LGSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 340.00 | 21.11 | 340.00 | 21.11 |
February | 308.00 | 21.11 | 295.33 | 21.11 | 295.33 | 21.11 |
March | 348.00 | 21.13 | 278.17 | 21.12 | 278.17 | 21.12 |
April | 325.17 | 21.92 | 101.00 | 21.74 | 99.67 | 21.62 |
May | 186.00 | 23.30 | 82.33 | 23.46 | 4.00 | 23.42 |
June | 88.83 | 23.92 | 208.33 | 23.93 | 53.50 | 23.93 |
July | 44.17 | 24.12 | 320.67 | 23.98 | 43.67 | 23.99 |
August | 37.50 | 23.88 | 308.00 | 23.93 | 35.33 | 23.92 |
September | 110.83 | 23.25 | 86.83 | 23.57 | 13.50 | 23.59 |
October | 305.83 | 21.90 | 39.00 | 21.85 | 34.67 | 21.78 |
November | 330.00 | 21.18 | 226.67 | 21.15 | 226.67 | 21.14 |
December | 338.00 | 21.11 | 338.00 | 21.11 | 338.00 | 21.11 |
Annual Sum or Average | 2762.33 | 21.71 | 2624.33 | 21.95 | 1762.50 | 21.80 |
Minimum of Months | 37.50 | 21.11 | 39.00 | 21.11 | 4.00 | 21.11 |
Maximum of Months | 348.00 | 24.12 | 340.00 | 23.98 | 340.00 | 23.99 |
Report: ComfortReportSimple55Monthly
For: SMSTORE5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.10 | 340.00 | 21.10 | 340.00 | 21.10 |
February | 308.00 | 21.11 | 298.17 | 21.11 | 298.17 | 21.11 |
March | 348.00 | 21.11 | 288.17 | 21.11 | 288.17 | 21.11 |
April | 325.67 | 21.46 | 125.67 | 21.37 | 124.67 | 21.31 |
May | 214.67 | 22.45 | 70.83 | 22.75 | 6.83 | 22.71 |
June | 133.17 | 23.52 | 175.00 | 23.75 | 69.17 | 23.79 |
July | 67.50 | 23.99 | 308.67 | 23.96 | 61.50 | 23.97 |
August | 61.67 | 23.57 | 298.83 | 23.86 | 41.33 | 23.87 |
September | 175.67 | 22.30 | 65.33 | 22.73 | 13.67 | 22.78 |
October | 319.50 | 21.37 | 57.33 | 21.34 | 56.17 | 21.31 |
November | 330.00 | 21.13 | 243.67 | 21.12 | 243.67 | 21.11 |
December | 338.00 | 21.11 | 338.00 | 21.11 | 338.00 | 21.11 |
Annual Sum or Average | 2961.83 | 21.57 | 2609.67 | 21.82 | 1881.33 | 21.71 |
Minimum of Months | 61.67 | 21.10 | 57.33 | 21.10 | 6.83 | 21.10 |
Maximum of Months | 348.00 | 23.99 | 340.00 | 23.96 | 340.00 | 23.97 |
Report: ComfortReportSimple55Monthly
For: SMSTORE6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.10 | 340.00 | 21.10 | 340.00 | 21.10 |
February | 308.00 | 21.11 | 300.83 | 21.11 | 300.83 | 21.11 |
March | 348.00 | 21.11 | 291.83 | 21.11 | 291.83 | 21.11 |
April | 326.17 | 21.42 | 137.67 | 21.34 | 136.83 | 21.28 |
May | 219.83 | 22.36 | 69.17 | 22.65 | 8.17 | 22.61 |
June | 145.50 | 23.46 | 164.17 | 23.71 | 69.67 | 23.75 |
July | 70.67 | 23.96 | 306.50 | 23.95 | 62.50 | 23.97 |
August | 71.83 | 23.53 | 294.33 | 23.85 | 45.50 | 23.85 |
September | 185.50 | 22.23 | 63.17 | 22.65 | 15.00 | 22.71 |
October | 323.67 | 21.36 | 66.00 | 21.32 | 66.00 | 21.28 |
November | 330.00 | 21.12 | 248.00 | 21.12 | 248.00 | 21.11 |
December | 338.00 | 21.11 | 338.00 | 21.11 | 338.00 | 21.11 |
Annual Sum or Average | 3007.17 | 21.57 | 2619.67 | 21.80 | 1922.33 | 21.70 |
Minimum of Months | 70.67 | 21.10 | 63.17 | 21.10 | 8.17 | 21.10 |
Maximum of Months | 348.00 | 23.96 | 340.00 | 23.95 | 340.00 | 23.97 |
Report: ComfortReportSimple55Monthly
For: SMSTORE7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.10 | 340.00 | 21.10 | 340.00 | 21.10 |
February | 308.00 | 21.11 | 306.33 | 21.11 | 306.33 | 21.11 |
March | 348.00 | 21.11 | 310.50 | 21.11 | 310.50 | 21.11 |
April | 327.00 | 21.37 | 168.17 | 21.29 | 167.33 | 21.24 |
May | 232.67 | 22.26 | 69.67 | 22.53 | 12.50 | 22.47 |
June | 160.33 | 23.34 | 152.83 | 23.62 | 70.67 | 23.68 |
July | 79.33 | 23.87 | 301.33 | 23.93 | 65.83 | 23.95 |
August | 82.00 | 23.47 | 284.33 | 23.82 | 51.17 | 23.83 |
September | 198.83 | 22.18 | 60.17 | 22.57 | 16.17 | 22.63 |
October | 330.17 | 21.37 | 84.17 | 21.32 | 84.17 | 21.28 |
November | 330.00 | 21.12 | 265.83 | 21.11 | 265.83 | 21.11 |
December | 338.00 | 21.11 | 338.00 | 21.11 | 338.00 | 21.11 |
Annual Sum or Average | 3074.33 | 21.57 | 2681.33 | 21.77 | 2028.50 | 21.67 |
Minimum of Months | 79.33 | 21.10 | 60.17 | 21.10 | 12.50 | 21.10 |
Maximum of Months | 348.00 | 23.87 | 340.00 | 23.93 | 340.00 | 23.95 |
Report: ComfortReportSimple55Monthly
For: SMSTORE8
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 340.00 | 21.11 | 340.00 | 21.11 |
February | 308.00 | 21.11 | 308.00 | 21.11 | 308.00 | 21.11 |
March | 348.00 | 21.11 | 345.67 | 21.11 | 345.67 | 21.11 |
April | 329.17 | 21.32 | 227.17 | 21.23 | 227.17 | 21.20 |
May | 248.67 | 22.12 | 71.83 | 22.26 | 30.17 | 22.16 |
June | 181.17 | 23.15 | 145.00 | 23.48 | 74.83 | 23.55 |
July | 89.33 | 23.72 | 292.50 | 23.90 | 70.50 | 23.92 |
August | 108.83 | 23.33 | 271.50 | 23.75 | 65.33 | 23.77 |
September | 217.83 | 22.08 | 54.00 | 22.40 | 16.67 | 22.45 |
October | 335.67 | 21.37 | 147.50 | 21.29 | 147.50 | 21.25 |
November | 330.00 | 21.11 | 312.00 | 21.11 | 312.00 | 21.11 |
December | 338.00 | 21.11 | 338.00 | 21.11 | 338.00 | 21.11 |
Annual Sum or Average | 3174.67 | 21.57 | 2853.17 | 21.72 | 2275.83 | 21.63 |
Minimum of Months | 89.33 | 21.11 | 54.00 | 21.11 | 16.67 | 21.11 |
Maximum of Months | 348.00 | 23.72 | 345.67 | 23.90 | 345.67 | 23.92 |
Report: OccupantComfortDataSummaryMonthly
For: LGSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 496.00000 | 20.91414 | 10.48365 | -0.8202 | 19.80113 |
February | 448.00000 | 20.93042 | 12.83091 | -0.7483 | 17.47126 |
March | 497.00000 | 21.02985 | 17.00397 | -0.6623 | 15.04178 |
April | 479.00000 | 21.96429 | 21.09693 | -0.3266 | 9.59049 |
May | 496.00000 | 23.60661 | 32.26245 | -0.6991 | 17.08663 |
June | 481.00000 | 23.89381 | 46.90277 | -0.4348 | 9.44615 |
July | 495.00000 | 23.91666 | 52.78642 | -0.3298 | 7.45353 |
August | 497.00000 | 23.91564 | 51.87999 | -0.3561 | 7.87390 |
September | 479.00000 | 23.74094 | 39.97938 | -0.5709 | 12.66973 |
October | 496.00000 | 22.32324 | 30.34136 | -0.1378 | 7.62339 |
November | 480.00000 | 21.08569 | 20.62829 | -0.5883 | 13.13477 |
December | 496.00000 | 20.94115 | 11.92051 | -0.7967 | 18.89844 |
Annual Sum or Average | 5840.00000 | 22.36332 | 29.10859 | -0.5382 | 12.99106 |
Minimum of Months | 448.00000 | 20.91414 | 10.48365 | -0.8202 | 7.45353 |
Maximum of Months | 497.00000 | 23.91666 | 52.78642 | -0.1378 | 19.80113 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 496.00000 | 20.97922 | 11.03442 | -0.7242 | 16.51964 |
February | 448.00000 | 21.05252 | 13.28978 | -0.6445 | 14.29779 |
March | 497.00000 | 21.19345 | 17.10579 | -0.5573 | 12.25075 |
April | 479.00000 | 22.01182 | 21.23963 | -0.2692 | 8.21770 |
May | 496.00000 | 23.41394 | 32.35692 | -0.7271 | 18.14216 |
June | 481.00000 | 23.85187 | 46.33346 | -0.4388 | 9.54631 |
July | 495.00000 | 23.89420 | 51.86045 | -0.3437 | 7.66610 |
August | 497.00000 | 23.88641 | 51.04385 | -0.3681 | 8.07831 |
September | 479.00000 | 23.49342 | 40.13610 | -0.6274 | 14.81004 |
October | 496.00000 | 22.16752 | 30.93852 | -0.1425 | 7.08672 |
November | 480.00000 | 21.31389 | 20.73847 | -0.4868 | 10.72671 |
December | 496.00000 | 20.99888 | 12.35850 | -0.7053 | 15.90450 |
Annual Sum or Average | 5840.00000 | 22.36195 | 29.13226 | -0.5023 | 11.92987 |
Minimum of Months | 448.00000 | 20.97922 | 11.03442 | -0.7271 | 7.08672 |
Maximum of Months | 497.00000 | 23.89420 | 51.86045 | -0.1425 | 18.14216 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 21.10559 | 7.74873 | -0.7455 | 16.88024 |
February | 336.00000 | 21.10619 | 9.95124 | -0.6739 | 14.79082 |
March | 379.00000 | 21.10784 | 14.05053 | -0.6065 | 12.99684 |
April | 360.00000 | 21.56690 | 18.53707 | -0.3826 | 9.34369 |
May | 375.00000 | 23.12385 | 32.43657 | -0.8190 | 22.37624 |
June | 366.00000 | 23.85293 | 46.57215 | -0.4403 | 10.05308 |
July | 369.00000 | 24.00055 | 52.47438 | -0.3044 | 7.34482 |
August | 379.00000 | 23.93454 | 51.98400 | -0.3460 | 7.94992 |
September | 360.00000 | 23.13533 | 39.71388 | -0.7395 | 19.35866 |
October | 371.00000 | 21.57423 | 29.34758 | -0.2829 | 8.08506 |
November | 360.00000 | 21.13558 | 18.25857 | -0.5531 | 11.78230 |
December | 369.00000 | 21.10600 | 9.33692 | -0.7281 | 16.33460 |
Annual Sum or Average | 4395.00000 | 22.23993 | 27.68927 | -0.5509 | 13.09519 |
Minimum of Months | 336.00000 | 21.10559 | 7.74873 | -0.8190 | 7.34482 |
Maximum of Months | 379.00000 | 24.00055 | 52.47438 | -0.2829 | 22.37624 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 21.10555 | 7.74865 | -0.7547 | 17.16955 |
February | 336.00000 | 21.10624 | 9.95094 | -0.6839 | 15.07226 |
March | 379.00000 | 21.10744 | 14.05088 | -0.6161 | 13.24351 |
April | 360.00000 | 21.53444 | 18.57703 | -0.3995 | 9.55664 |
May | 375.00000 | 23.07624 | 32.52846 | -0.8411 | 23.29672 |
June | 366.00000 | 23.83723 | 46.63501 | -0.4484 | 10.29706 |
July | 369.00000 | 23.99946 | 52.49596 | -0.3045 | 7.35090 |
August | 379.00000 | 23.93031 | 52.03156 | -0.3481 | 7.99706 |
September | 360.00000 | 23.09118 | 39.83312 | -0.7589 | 20.12023 |
October | 371.00000 | 21.54040 | 29.41905 | -0.3007 | 8.26392 |
November | 360.00000 | 21.13195 | 18.26869 | -0.5655 | 12.06562 |
December | 369.00000 | 21.10592 | 9.33689 | -0.7371 | 16.61291 |
Annual Sum or Average | 4395.00000 | 22.22464 | 27.72816 | -0.5623 | 13.40733 |
Minimum of Months | 336.00000 | 21.10555 | 7.74865 | -0.8411 | 7.35090 |
Maximum of Months | 379.00000 | 23.99946 | 52.49596 | -0.3007 | 23.29672 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 21.10544 | 7.74879 | -0.7651 | 17.50860 |
February | 336.00000 | 21.10610 | 9.95130 | -0.6960 | 15.43117 |
March | 379.00000 | 21.10735 | 14.05093 | -0.6281 | 13.56827 |
April | 360.00000 | 21.51938 | 18.59819 | -0.4095 | 9.72404 |
May | 375.00000 | 23.05299 | 32.58550 | -0.8512 | 23.66362 |
June | 366.00000 | 23.82300 | 46.74601 | -0.4563 | 10.47284 |
July | 369.00000 | 23.99192 | 52.62430 | -0.3100 | 7.42894 |
August | 379.00000 | 23.92123 | 52.15410 | -0.3542 | 8.09871 |
September | 360.00000 | 23.07956 | 39.88879 | -0.7622 | 20.15351 |
October | 371.00000 | 21.53647 | 29.43178 | -0.3054 | 8.33856 |
November | 360.00000 | 21.12816 | 18.27806 | -0.5783 | 12.37523 |
December | 369.00000 | 21.10580 | 9.33699 | -0.7476 | 16.94854 |
Annual Sum or Average | 4395.00000 | 22.21719 | 27.77180 | -0.5711 | 13.62893 |
Minimum of Months | 336.00000 | 21.10544 | 7.74879 | -0.8512 | 7.42894 |
Maximum of Months | 379.00000 | 23.99192 | 52.62430 | -0.3054 | 23.66362 |
Report: OccupantComfortDataSummaryMonthly
For: LGSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10630 | 10.90590 | -0.7848 | 18.13587 |
February | 308.00000 | 21.10703 | 13.38417 | -0.7129 | 15.91102 |
March | 348.00000 | 21.12732 | 17.77305 | -0.6372 | 13.82706 |
April | 330.00000 | 21.95331 | 21.53561 | -0.3340 | 9.13556 |
May | 344.00000 | 23.58558 | 33.95276 | -0.7170 | 17.81487 |
June | 336.00000 | 23.90853 | 47.17839 | -0.4365 | 9.46650 |
July | 338.00000 | 23.94959 | 52.46493 | -0.3240 | 7.48596 |
August | 348.00000 | 23.92242 | 52.69403 | -0.3539 | 7.84113 |
September | 330.00000 | 23.69910 | 40.50108 | -0.5986 | 13.59757 |
October | 340.00000 | 22.10367 | 31.80088 | -0.1997 | 7.90412 |
November | 330.00000 | 21.17953 | 21.57869 | -0.5851 | 12.65615 |
December | 338.00000 | 21.10660 | 12.65452 | -0.7672 | 17.56522 |
Annual Sum or Average | 4030.00000 | 22.40692 | 29.85120 | -0.5365 | 12.59294 |
Minimum of Months | 308.00000 | 21.10630 | 10.90590 | -0.7848 | 7.48596 |
Maximum of Months | 348.00000 | 23.94959 | 52.69403 | -0.1997 | 18.13587 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10488 | 9.05563 | -0.7835 | 18.08977 |
February | 308.00000 | 21.10573 | 11.30753 | -0.7176 | 16.04892 |
March | 348.00000 | 21.10659 | 15.46069 | -0.6506 | 14.15560 |
April | 330.00000 | 21.49416 | 19.85059 | -0.4358 | 10.12632 |
May | 344.00000 | 22.99405 | 34.03002 | -0.8910 | 24.95451 |
June | 336.00000 | 23.74495 | 47.93739 | -0.4980 | 11.27726 |
July | 338.00000 | 23.91434 | 53.64773 | -0.3465 | 7.88100 |
August | 348.00000 | 23.84767 | 53.29174 | -0.3900 | 8.62046 |
September | 330.00000 | 23.03733 | 41.08882 | -0.7938 | 21.20218 |
October | 340.00000 | 21.51873 | 30.78083 | -0.3276 | 8.63548 |
November | 330.00000 | 21.12656 | 19.54671 | -0.6044 | 13.00800 |
December | 338.00000 | 21.10530 | 10.66116 | -0.7673 | 17.56261 |
Annual Sum or Average | 4030.00000 | 22.18579 | 29.04791 | -0.5996 | 14.28293 |
Minimum of Months | 308.00000 | 21.10488 | 9.05563 | -0.8910 | 7.88100 |
Maximum of Months | 348.00000 | 23.91434 | 53.64773 | -0.3276 | 24.95451 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10482 | 9.05578 | -0.7856 | 18.15803 |
February | 308.00000 | 21.10567 | 11.30781 | -0.7209 | 16.14787 |
March | 348.00000 | 21.10658 | 15.46078 | -0.6552 | 14.27901 |
April | 330.00000 | 21.45405 | 19.89778 | -0.4550 | 10.38223 |
May | 344.00000 | 22.91272 | 34.19644 | -0.9293 | 26.60304 |
June | 336.00000 | 23.70365 | 48.08480 | -0.5199 | 11.98637 |
July | 338.00000 | 23.90859 | 53.73021 | -0.3528 | 7.99698 |
August | 348.00000 | 23.83459 | 53.38944 | -0.3992 | 8.83958 |
September | 330.00000 | 22.95964 | 41.30009 | -0.8304 | 22.68336 |
October | 340.00000 | 21.47906 | 30.86463 | -0.3476 | 8.84307 |
November | 330.00000 | 21.12445 | 19.55221 | -0.6105 | 13.15302 |
December | 338.00000 | 21.10525 | 10.66130 | -0.7695 | 17.63515 |
Annual Sum or Average | 4030.00000 | 22.16061 | 29.11850 | -0.6138 | 14.71312 |
Minimum of Months | 308.00000 | 21.10482 | 9.05578 | -0.9293 | 7.99698 |
Maximum of Months | 348.00000 | 23.90859 | 53.73021 | -0.3476 | 26.60304 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10466 | 9.05595 | -0.7983 | 18.58602 |
February | 308.00000 | 21.10547 | 11.30799 | -0.7366 | 16.63240 |
March | 348.00000 | 21.10638 | 15.46091 | -0.6744 | 14.81595 |
April | 330.00000 | 21.39876 | 19.96286 | -0.4892 | 10.95704 |
May | 344.00000 | 22.79593 | 34.47425 | -0.9862 | 29.06063 |
June | 336.00000 | 23.62876 | 48.43761 | -0.5565 | 13.20368 |
July | 338.00000 | 23.89453 | 53.97694 | -0.3637 | 8.22611 |
August | 348.00000 | 23.80831 | 53.65073 | -0.4155 | 9.25290 |
September | 330.00000 | 22.86110 | 41.60381 | -0.8760 | 24.45443 |
October | 340.00000 | 21.44182 | 30.94798 | -0.3741 | 9.20064 |
November | 330.00000 | 21.11989 | 19.56324 | -0.6304 | 13.66477 |
December | 338.00000 | 21.10510 | 10.66145 | -0.7829 | 18.07606 |
Annual Sum or Average | 4030.00000 | 22.12478 | 29.25307 | -0.6395 | 15.49995 |
Minimum of Months | 308.00000 | 21.10466 | 9.05595 | -0.9862 | 8.22611 |
Maximum of Months | 348.00000 | 23.89453 | 53.97694 | -0.3637 | 29.06063 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE8
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10505 | 8.91138 | -0.8898 | 21.88120 |
February | 308.00000 | 21.10581 | 11.12215 | -0.8243 | 19.57309 |
March | 348.00000 | 21.10652 | 15.28592 | -0.7646 | 17.59467 |
April | 330.00000 | 21.32617 | 19.87760 | -0.5798 | 12.95770 |
May | 344.00000 | 22.61326 | 34.72209 | -1.1007 | 34.21177 |
June | 336.00000 | 23.49833 | 48.93304 | -0.6215 | 15.60648 |
July | 338.00000 | 23.86090 | 54.38123 | -0.3752 | 8.72527 |
August | 348.00000 | 23.73470 | 54.27632 | -0.4490 | 10.36955 |
September | 330.00000 | 22.70007 | 41.89378 | -0.9647 | 28.20390 |
October | 340.00000 | 21.40310 | 30.84670 | -0.4435 | 10.48829 |
November | 330.00000 | 21.11391 | 19.47068 | -0.7090 | 15.93463 |
December | 338.00000 | 21.10542 | 10.50563 | -0.8711 | 21.19052 |
Annual Sum or Average | 4030.00000 | 22.06634 | 29.34952 | -0.7151 | 18.04754 |
Minimum of Months | 308.00000 | 21.10505 | 8.91138 | -1.1007 | 8.72527 |
Maximum of Months | 348.00000 | 23.86090 | 54.38123 | -0.3752 | 34.21177 |
Report: DXReportMonthly
For: PSZ-AC_1:1 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 |
April | 0.260341E+09 | 69749941.40 | 55.83 | 0.227791E+09 | 32550564.19 | 0.00 | 0.63 | 23-APR-16:10 | 0.00 | 01-APR-00:10 | 11315.79 | 23-APR-16:20 | 9952.51 | 23-APR-16:03 | 1420.63 | 23-APR-17:00 | 3008.68 | 23-APR-16:10 | 0.00 | 01-APR-00:10 |
May | 0.391283E+10 | 0.103460E+10 | 270.93 | 0.342298E+10 | 0.489847E+09 | 0.00 | 1.00 | 18-MAY-08:62 | 0.00 | 01-MAY-00:10 | 42509.29 | 26-MAY-08:62 | 28585.56 | 26-MAY-08:62 | 13923.73 | 26-MAY-08:62 | 9173.14 | 26-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.964212E+10 | 0.246305E+10 | 359.31 | 0.722624E+10 | 0.241588E+10 | 0.00 | 1.00 | 07-JUN-08:62 | 0.00 | 01-JUN-00:10 | 45371.60 | 30-JUN-08:61 | 29126.82 | 28-JUN-08:03 | 20646.98 | 25-JUN-07:03 | 9970.68 | 30-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.154848E+11 | 0.386461E+10 | 423.95 | 0.108760E+11 | 0.460886E+10 | 0.00 | 1.00 | 01-JUL-08:62 | 0.00 | 01-JUL-00:05 | 45361.80 | 23-JUL-07:02 | 31147.88 | 12-JUL-08:62 | 24306.04 | 05-JUL-08:03 | 9759.75 | 29-JUL-08:62 | 0.00 | 01-JUL-00:05 |
August | 0.112484E+11 | 0.280267E+10 | 383.99 | 0.792761E+10 | 0.332075E+10 | 0.00 | 1.00 | 01-AUG-08:62 | 0.00 | 01-AUG-00:10 | 44383.88 | 30-AUG-08:62 | 28231.18 | 26-AUG-08:62 | 21731.91 | 30-AUG-08:62 | 9433.86 | 30-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.194798E+10 | 0.505740E+09 | 254.48 | 0.158527E+10 | 0.362715E+09 | 0.00 | 1.00 | 01-SEP-08:62 | 0.00 | 01-SEP-00:05 | 42947.39 | 01-SEP-08:62 | 22890.33 | 01-SEP-08:62 | 20057.06 | 01-SEP-08:62 | 9244.04 | 01-SEP-08:62 | 0.00 | 01-SEP-00:05 |
October | 0.190649E+09 | 52152291.08 | 83.08 | 0.178665E+09 | 11984312.75 | 0.00 | 0.33 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 | 5350.94 | 19-OCT-15:00 | 5146.23 | 19-OCT-15:00 | 587.52 | 22-OCT-13:00 | 1444.12 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 179875.21 | 51879.69 | 0.50 | 145562.15 | 34313.06 | 0.00 | 0.01 | 01-NOV-17:30 | 0.00 | 01-NOV-00:05 | 228.53 | 01-NOV-17:30 | 184.97 | 01-NOV-17:30 | 43.56 | 01-NOV-17:30 | 65.87 | 01-NOV-17:30 | 0.00 | 01-NOV-00:05 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.426873E+11 | 0.107926E+11 | 1832.08 | 0.314447E+11 | 0.112426E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.154848E+11 | 0.386461E+10 | 423.95 | 0.108760E+11 | 0.460886E+10 | 0.00 | 1.00 | 0.00 | 45371.60 | 31147.88 | 24306.04 | 9970.68 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_2:2 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 |
April | 0.176581E+09 | 44179568.36 | 15.44 | 0.156550E+09 | 20031692.52 | 0.00 | 1.00 | 23-APR-18:42 | 0.00 | 01-APR-00:10 | 21211.69 | 23-APR-18:42 | 19424.93 | 23-APR-18:48 | 3057.55 | 23-APR-20:40 | 4698.80 | 23-APR-18:42 | 0.00 | 01-APR-00:10 |
May | 0.265423E+10 | 0.660218E+09 | 165.88 | 0.233508E+10 | 0.319144E+09 | 0.00 | 1.00 | 10-MAY-20:01 | 0.00 | 01-MAY-00:10 | 22116.61 | 26-MAY-08:62 | 20326.77 | 10-MAY-20:08 | 7171.00 | 26-MAY-20:20 | 4790.53 | 25-MAY-20:32 | 0.00 | 01-MAY-00:10 |
June | 0.636690E+10 | 0.153762E+10 | 292.74 | 0.468735E+10 | 0.167955E+10 | 0.00 | 1.00 | 04-JUN-17:01 | 0.00 | 01-JUN-00:10 | 23343.95 | 30-JUN-08:61 | 20570.16 | 17-JUN-18:08 | 12509.06 | 19-JUN-20:03 | 5104.30 | 30-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.998069E+10 | 0.235576E+10 | 377.28 | 0.688302E+10 | 0.309766E+10 | 0.00 | 1.00 | 01-JUL-08:62 | 0.00 | 01-JUL-00:05 | 23501.37 | 23-JUL-07:02 | 18021.95 | 02-JUL-17:10 | 12629.10 | 25-JUL-20:03 | 5002.02 | 29-JUL-08:62 | 0.00 | 01-JUL-00:05 |
August | 0.730178E+10 | 0.172655E+10 | 339.41 | 0.506408E+10 | 0.223770E+10 | 0.00 | 1.00 | 01-AUG-08:62 | 0.00 | 01-AUG-00:10 | 23305.01 | 31-AUG-20:03 | 19465.62 | 05-AUG-18:02 | 12186.43 | 28-AUG-20:03 | 4951.54 | 31-AUG-20:03 | 0.00 | 01-AUG-00:10 |
September | 0.128137E+10 | 0.317826E+09 | 130.95 | 0.103660E+10 | 0.244771E+09 | 0.00 | 1.00 | 01-SEP-08:62 | 0.00 | 01-SEP-00:05 | 22400.05 | 17-SEP-17:03 | 19071.53 | 04-SEP-17:35 | 9485.11 | 01-SEP-08:62 | 4739.02 | 17-SEP-17:03 | 0.00 | 01-SEP-00:05 |
October | 0.129655E+09 | 34114642.48 | 23.67 | 0.121217E+09 | 8437590.82 | 0.00 | 1.00 | 22-OCT-17:02 | 0.00 | 01-OCT-00:10 | 10102.32 | 22-OCT-17:02 | 8945.76 | 22-OCT-17:02 | 1603.89 | 22-OCT-17:35 | 2141.71 | 22-OCT-17:02 | 0.00 | 01-OCT-00:10 |
November | 338010.72 | 94439.16 | 0.17 | 270765.84 | 67244.88 | 0.00 | 0.07 | 01-NOV-20:40 | 0.00 | 01-NOV-00:05 | 563.35 | 01-NOV-20:40 | 451.28 | 01-NOV-20:40 | 112.07 | 01-NOV-20:40 | 157.40 | 01-NOV-20:40 | 0.00 | 01-NOV-00:05 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.278915E+11 | 0.667636E+10 | 1345.52 | 0.202842E+11 | 0.760737E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.998069E+10 | 0.235576E+10 | 377.28 | 0.688302E+10 | 0.309766E+10 | 0.00 | 1.00 | 0.00 | 23501.37 | 20570.16 | 12629.10 | 5104.30 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_3:3 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 |
April | 52846118.17 | 14107766.45 | 5.83 | 46778996.09 | 6067122.09 | 0.00 | 0.53 | 23-APR-16:00 | 0.00 | 01-APR-00:10 | 4884.97 | 23-APR-16:00 | 4423.94 | 23-APR-16:00 | 507.75 | 23-APR-14:00 | 1314.29 | 23-APR-16:00 | 0.00 | 01-APR-00:10 |
May | 0.181036E+10 | 0.465950E+09 | 130.96 | 0.158784E+10 | 0.222517E+09 | 0.00 | 1.00 | 18-MAY-07:03 | 0.00 | 01-MAY-00:10 | 22001.35 | 26-MAY-07:02 | 15338.70 | 26-MAY-07:02 | 6662.64 | 26-MAY-07:02 | 4672.02 | 26-MAY-07:02 | 0.00 | 01-MAY-00:10 |
June | 0.456322E+10 | 0.112417E+10 | 237.89 | 0.341743E+10 | 0.114578E+10 | 0.00 | 1.00 | 07-JUN-07:03 | 0.00 | 01-JUN-00:10 | 23931.98 | 30-JUN-07:01 | 14583.64 | 29-JUN-07:01 | 11324.28 | 23-JUN-07:03 | 5119.13 | 30-JUN-07:01 | 0.00 | 01-JUN-00:10 |
July | 0.702062E+10 | 0.169113E+10 | 302.99 | 0.495120E+10 | 0.206941E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 23770.02 | 23-JUL-08:61 | 15497.14 | 07-JUL-07:02 | 12124.79 | 05-JUL-07:03 | 5019.78 | 30-JUL-08:62 | 0.00 | 01-JUL-00:05 |
August | 0.510787E+10 | 0.123643E+10 | 281.01 | 0.359294E+10 | 0.151493E+10 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 22795.24 | 30-AUG-07:02 | 13985.94 | 14-AUG-07:02 | 11437.13 | 30-AUG-07:02 | 4793.48 | 30-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.825787E+09 | 0.209590E+09 | 101.77 | 0.681524E+09 | 0.144263E+09 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:05 | 22208.55 | 01-SEP-07:02 | 13949.59 | 02-SEP-07:02 | 10896.53 | 01-SEP-07:02 | 4707.21 | 01-SEP-07:02 | 0.00 | 01-SEP-00:05 |
October | 66994319.03 | 18134197.69 | 16.50 | 63150758.30 | 3843560.73 | 0.00 | 0.28 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 | 2319.61 | 19-OCT-15:00 | 2243.58 | 19-OCT-15:00 | 250.69 | 22-OCT-13:40 | 623.77 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.194477E+11 | 0.475951E+10 | 1076.94 | 0.143409E+11 | 0.510682E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.702062E+10 | 0.169113E+10 | 302.99 | 0.495120E+10 | 0.206941E+10 | 0.00 | 1.00 | 0.00 | 23931.98 | 15497.14 | 12124.79 | 5119.13 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_4:4 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 |
April | 48528910.75 | 13035367.12 | 4.33 | 42960574.56 | 5568336.19 | 0.00 | 0.51 | 23-APR-16:00 | 0.00 | 01-APR-00:10 | 4669.94 | 23-APR-16:00 | 4230.33 | 23-APR-16:00 | 478.34 | 23-APR-14:40 | 1264.17 | 23-APR-16:00 | 0.00 | 01-APR-00:10 |
May | 0.176913E+10 | 0.456112E+09 | 129.38 | 0.155094E+10 | 0.218184E+09 | 0.00 | 1.00 | 18-MAY-07:03 | 0.00 | 01-MAY-00:10 | 22058.17 | 26-MAY-07:02 | 15401.76 | 26-MAY-07:02 | 6656.41 | 26-MAY-07:02 | 4684.03 | 26-MAY-07:02 | 0.00 | 01-MAY-00:10 |
June | 0.452144E+10 | 0.111444E+10 | 235.92 | 0.338416E+10 | 0.113729E+10 | 0.00 | 1.00 | 07-JUN-07:03 | 0.00 | 01-JUN-00:10 | 23998.45 | 30-JUN-07:01 | 14646.56 | 29-JUN-07:01 | 11350.96 | 23-JUN-07:03 | 5132.05 | 30-JUN-07:01 | 0.00 | 01-JUN-00:10 |
July | 0.701939E+10 | 0.169150E+10 | 302.95 | 0.495370E+10 | 0.206569E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 23832.44 | 23-JUL-08:61 | 15574.97 | 30-JUL-08:62 | 12140.90 | 05-JUL-07:03 | 5032.78 | 30-JUL-08:62 | 0.00 | 01-JUL-00:05 |
August | 0.507877E+10 | 0.123052E+10 | 280.84 | 0.357462E+10 | 0.150415E+10 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 22853.47 | 30-AUG-07:02 | 14040.93 | 14-AUG-07:02 | 11458.46 | 30-AUG-07:02 | 4805.65 | 30-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.795640E+09 | 0.201880E+09 | 98.10 | 0.657219E+09 | 0.138421E+09 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:05 | 22265.98 | 01-SEP-07:02 | 13999.54 | 02-SEP-07:02 | 10915.23 | 01-SEP-07:02 | 4719.31 | 01-SEP-07:02 | 0.00 | 01-SEP-00:05 |
October | 56430983.33 | 15345643.75 | 15.00 | 53254841.37 | 3176141.97 | 0.00 | 0.25 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 | 2110.81 | 19-OCT-15:00 | 2044.58 | 19-OCT-15:00 | 218.84 | 22-OCT-13:40 | 571.30 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.192893E+11 | 0.472284E+10 | 1066.52 | 0.142169E+11 | 0.507248E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.701939E+10 | 0.169150E+10 | 302.95 | 0.495370E+10 | 0.206569E+10 | 0.00 | 1.00 | 0.00 | 23998.45 | 15574.97 | 12140.90 | 5132.05 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_5:5 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 |
April | 46872045.56 | 12619842.06 | 4.00 | 41420193.51 | 5451852.05 | 0.00 | 0.50 | 23-APR-16:00 | 0.00 | 01-APR-00:10 | 4572.81 | 23-APR-16:00 | 4134.73 | 23-APR-16:00 | 474.28 | 23-APR-14:50 | 1240.67 | 23-APR-16:00 | 0.00 | 01-APR-00:10 |
May | 0.170878E+10 | 0.441701E+09 | 126.82 | 0.149600E+10 | 0.212780E+09 | 0.00 | 1.00 | 18-MAY-07:03 | 0.00 | 01-MAY-00:10 | 21984.68 | 26-MAY-07:02 | 15298.89 | 26-MAY-07:02 | 6685.80 | 26-MAY-07:02 | 4668.61 | 26-MAY-07:02 | 0.00 | 01-MAY-00:10 |
June | 0.440278E+10 | 0.108684E+10 | 230.89 | 0.328835E+10 | 0.111443E+10 | 0.00 | 1.00 | 07-JUN-07:03 | 0.00 | 01-JUN-00:10 | 23912.99 | 30-JUN-07:01 | 14545.39 | 29-JUN-07:01 | 10990.11 | 23-JUN-07:03 | 5116.02 | 30-JUN-07:01 | 0.00 | 01-JUN-00:10 |
July | 0.686505E+10 | 0.165696E+10 | 301.87 | 0.483533E+10 | 0.202973E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 23755.41 | 23-JUL-08:61 | 15463.56 | 07-JUL-07:02 | 12136.28 | 05-JUL-07:03 | 5016.60 | 30-JUL-08:62 | 0.00 | 01-JUL-00:05 |
August | 0.493955E+10 | 0.119900E+10 | 278.54 | 0.347274E+10 | 0.146682E+10 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 22779.33 | 30-AUG-07:02 | 13958.97 | 14-AUG-07:02 | 11461.37 | 30-AUG-07:02 | 4790.31 | 30-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.758986E+09 | 0.192735E+09 | 94.15 | 0.627152E+09 | 0.131834E+09 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:05 | 22193.94 | 01-SEP-07:02 | 13913.16 | 02-SEP-07:02 | 10922.15 | 01-SEP-07:02 | 4704.18 | 01-SEP-07:02 | 0.00 | 01-SEP-00:05 |
October | 50310899.07 | 13718642.90 | 14.17 | 47453654.22 | 2857244.85 | 0.00 | 0.24 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 | 1981.47 | 19-OCT-15:00 | 1915.96 | 19-OCT-15:00 | 203.67 | 22-OCT-13:50 | 538.29 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.187723E+11 | 0.460358E+10 | 1050.44 | 0.138084E+11 | 0.496390E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.686505E+10 | 0.165696E+10 | 301.87 | 0.483533E+10 | 0.202973E+10 | 0.00 | 1.00 | 0.00 | 23912.99 | 15463.56 | 12136.28 | 5116.02 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_6:6 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 |
April | 93618389.09 | 25569584.91 | 28.00 | 80576729.44 | 13041659.65 | 0.00 | 0.52 | 23-APR-15:00 | 0.00 | 01-APR-00:10 | 9020.51 | 23-APR-15:00 | 7690.46 | 23-APR-15:00 | 1330.05 | 23-APR-15:00 | 2427.59 | 23-APR-15:00 | 0.00 | 01-APR-00:10 |
May | 0.312817E+10 | 0.830302E+09 | 186.40 | 0.267551E+10 | 0.452662E+09 | 0.00 | 1.00 | 18-MAY-08:62 | 0.00 | 01-MAY-00:10 | 41331.02 | 26-MAY-08:62 | 28377.89 | 26-MAY-08:62 | 12953.13 | 26-MAY-08:62 | 8924.73 | 26-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.753759E+10 | 0.193150E+10 | 267.73 | 0.568015E+10 | 0.185744E+10 | 0.00 | 1.00 | 07-JUN-08:62 | 0.00 | 01-JUN-00:10 | 44149.99 | 25-JUN-09:01 | 31841.49 | 18-JUN-09:02 | 20884.70 | 23-JUN-08:62 | 9718.18 | 30-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.117094E+11 | 0.292712E+10 | 304.65 | 0.834853E+10 | 0.336087E+10 | 0.00 | 1.00 | 01-JUL-08:62 | 0.00 | 01-JUL-00:05 | 44508.95 | 23-JUL-09:01 | 30156.86 | 12-JUL-08:62 | 23160.46 | 05-JUL-08:03 | 9661.31 | 23-JUL-09:01 | 0.00 | 01-JUL-00:05 |
August | 0.893443E+10 | 0.223003E+10 | 295.70 | 0.627715E+10 | 0.265728E+10 | 0.00 | 1.00 | 01-AUG-08:62 | 0.00 | 01-AUG-00:10 | 43273.36 | 30-AUG-08:62 | 28907.00 | 13-AUG-09:02 | 21689.53 | 29-AUG-08:62 | 9199.37 | 30-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.150907E+10 | 0.391302E+09 | 165.89 | 0.124473E+10 | 0.264349E+09 | 0.00 | 1.00 | 01-SEP-08:62 | 0.00 | 01-SEP-00:05 | 41896.88 | 01-SEP-08:62 | 22380.97 | 01-SEP-08:62 | 19515.91 | 01-SEP-08:62 | 9017.34 | 01-SEP-08:62 | 0.00 | 01-SEP-00:05 |
October | 0.124664E+09 | 34290787.61 | 38.00 | 0.117305E+09 | 7359117.32 | 0.00 | 0.29 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 | 4617.34 | 19-OCT-15:00 | 4393.28 | 19-OCT-15:00 | 477.26 | 22-OCT-14:10 | 1258.39 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.330369E+11 | 0.837012E+10 | 1286.37 | 0.244239E+11 | 0.861301E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.117094E+11 | 0.292712E+10 | 304.65 | 0.834853E+10 | 0.336087E+10 | 0.00 | 1.00 | 0.00 | 44508.95 | 31841.49 | 23160.46 | 9718.18 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_7:7 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 |
April | 42960360.74 | 11565429.07 | 3.83 | 37342081.43 | 5618279.31 | 0.00 | 0.51 | 23-APR-15:00 | 0.00 | 01-APR-00:10 | 4560.66 | 23-APR-15:00 | 3963.20 | 23-APR-15:00 | 597.46 | 23-APR-15:00 | 1208.68 | 23-APR-15:00 | 0.00 | 01-APR-00:10 |
May | 0.162506E+10 | 0.420314E+09 | 120.48 | 0.140638E+10 | 0.218684E+09 | 0.00 | 1.00 | 25-MAY-08:62 | 0.00 | 01-MAY-00:10 | 21376.56 | 26-MAY-08:62 | 14624.14 | 26-MAY-08:62 | 6752.41 | 26-MAY-08:62 | 4534.02 | 26-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.421707E+10 | 0.103996E+10 | 223.20 | 0.311190E+10 | 0.110517E+10 | 0.00 | 1.00 | 07-JUN-08:62 | 0.00 | 01-JUN-00:10 | 22899.78 | 30-JUN-08:61 | 15188.02 | 28-JUN-08:03 | 9913.24 | 19-JUN-08:62 | 4937.14 | 30-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.657634E+10 | 0.158349E+10 | 291.47 | 0.458976E+10 | 0.198659E+10 | 0.00 | 1.00 | 01-JUL-08:62 | 0.00 | 01-JUL-00:05 | 23038.40 | 23-JUL-09:01 | 15616.73 | 12-JUL-08:62 | 12017.02 | 05-JUL-08:03 | 4906.06 | 30-JUL-09:01 | 0.00 | 01-JUL-00:05 |
August | 0.479614E+10 | 0.116187E+10 | 268.22 | 0.332792E+10 | 0.146822E+10 | 0.00 | 1.00 | 01-AUG-08:62 | 0.00 | 01-AUG-00:10 | 22359.89 | 30-AUG-08:62 | 14035.63 | 26-AUG-08:62 | 11180.42 | 29-AUG-08:62 | 4669.88 | 30-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.724866E+09 | 0.183644E+09 | 88.55 | 0.597312E+09 | 0.127554E+09 | 0.00 | 1.00 | 01-SEP-08:62 | 0.00 | 01-SEP-00:05 | 21666.55 | 01-SEP-08:62 | 11526.69 | 01-SEP-08:62 | 10139.85 | 01-SEP-08:62 | 4580.28 | 01-SEP-08:62 | 0.00 | 01-SEP-00:05 |
October | 49101567.62 | 13340186.96 | 12.67 | 46291080.41 | 2810487.21 | 0.00 | 0.27 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 | 2171.51 | 19-OCT-15:00 | 2074.24 | 19-OCT-15:00 | 209.68 | 22-OCT-14:10 | 585.31 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.180316E+11 | 0.441419E+10 | 1008.42 | 0.131169E+11 | 0.491464E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.657634E+10 | 0.158349E+10 | 291.47 | 0.458976E+10 | 0.198659E+10 | 0.00 | 1.00 | 0.00 | 23038.40 | 15616.73 | 12017.02 | 4937.14 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_8:8 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 |
April | 38631104.28 | 10485569.91 | 3.67 | 33495191.63 | 5135912.65 | 0.00 | 0.48 | 23-APR-15:00 | 0.00 | 01-APR-00:10 | 4241.08 | 23-APR-15:00 | 3673.25 | 23-APR-15:00 | 567.83 | 23-APR-15:00 | 1133.58 | 23-APR-15:00 | 0.00 | 01-APR-00:10 |
May | 0.155260E+10 | 0.402672E+09 | 118.01 | 0.133979E+10 | 0.212812E+09 | 0.00 | 1.00 | 25-MAY-08:62 | 0.00 | 01-MAY-00:10 | 21291.74 | 26-MAY-08:62 | 14522.98 | 26-MAY-08:62 | 6768.77 | 26-MAY-08:62 | 4516.15 | 26-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.411566E+10 | 0.101559E+10 | 219.98 | 0.302474E+10 | 0.109093E+10 | 0.00 | 1.00 | 07-JUN-08:62 | 0.00 | 01-JUN-00:10 | 22808.42 | 30-JUN-08:61 | 15056.88 | 28-JUN-08:03 | 9456.37 | 30-JUN-08:04 | 4918.10 | 30-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.648217E+10 | 0.156192E+10 | 290.69 | 0.451441E+10 | 0.196776E+10 | 0.00 | 1.00 | 01-JUL-08:62 | 0.00 | 01-JUL-00:05 | 22945.79 | 23-JUL-09:01 | 15504.18 | 12-JUL-08:62 | 11994.86 | 05-JUL-08:03 | 4887.01 | 30-JUL-09:01 | 0.00 | 01-JUL-00:05 |
August | 0.470161E+10 | 0.114009E+10 | 265.21 | 0.325671E+10 | 0.144490E+10 | 0.00 | 1.00 | 01-AUG-08:62 | 0.00 | 01-AUG-00:10 | 22273.15 | 30-AUG-08:62 | 13945.04 | 26-AUG-08:62 | 11161.92 | 29-AUG-08:62 | 4651.85 | 30-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.682397E+09 | 0.172726E+09 | 83.21 | 0.561048E+09 | 0.121348E+09 | 0.00 | 1.00 | 01-SEP-08:62 | 0.00 | 01-SEP-00:05 | 21582.33 | 01-SEP-08:62 | 11455.17 | 01-SEP-08:62 | 10127.16 | 01-SEP-08:62 | 4562.54 | 01-SEP-08:62 | 0.00 | 01-SEP-00:05 |
October | 40393345.03 | 11025173.41 | 11.50 | 38078653.95 | 2314691.08 | 0.00 | 0.25 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 | 1993.56 | 19-OCT-15:00 | 1900.54 | 19-OCT-15:00 | 184.81 | 22-OCT-14:10 | 540.21 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.176135E+11 | 0.431452E+10 | 992.27 | 0.127683E+11 | 0.484520E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.648217E+10 | 0.156192E+10 | 290.69 | 0.451441E+10 | 0.196776E+10 | 0.00 | 1.00 | 0.00 | 22945.79 | 15504.18 | 11994.86 | 4918.10 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_9:9 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 |
April | 32402601.29 | 8906563.50 | 3.33 | 28035945.87 | 4366655.42 | 0.00 | 0.43 | 23-APR-15:00 | 0.00 | 01-APR-00:10 | 3751.22 | 23-APR-15:00 | 3238.27 | 23-APR-15:00 | 512.96 | 23-APR-15:00 | 1016.44 | 23-APR-15:00 | 0.00 | 01-APR-00:10 |
May | 0.141635E+10 | 0.369799E+09 | 110.26 | 0.121929E+10 | 0.197058E+09 | 0.00 | 1.00 | 26-MAY-08:62 | 0.00 | 01-MAY-00:10 | 21231.94 | 26-MAY-08:62 | 14411.38 | 26-MAY-08:62 | 6820.57 | 26-MAY-08:62 | 4503.83 | 26-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.390223E+10 | 0.965325E+09 | 212.42 | 0.285406E+10 | 0.104818E+10 | 0.00 | 1.00 | 18-JUN-09:02 | 0.00 | 01-JUN-00:10 | 22744.11 | 30-JUN-08:61 | 14652.14 | 27-JUN-08:62 | 9464.22 | 25-JUN-09:03 | 4906.01 | 30-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.626389E+10 | 0.151288E+10 | 288.74 | 0.435392E+10 | 0.190997E+10 | 0.00 | 1.00 | 01-JUL-08:62 | 0.00 | 01-JUL-00:05 | 22878.48 | 23-JUL-09:01 | 14694.77 | 25-JUL-08:62 | 11946.10 | 05-JUL-08:62 | 4874.43 | 30-JUL-09:01 | 0.00 | 01-JUL-00:05 |
August | 0.448481E+10 | 0.109071E+10 | 259.19 | 0.310462E+10 | 0.138019E+10 | 0.00 | 1.00 | 01-AUG-08:62 | 0.00 | 01-AUG-00:10 | 22216.01 | 30-AUG-08:62 | 13858.48 | 26-AUG-08:62 | 10917.20 | 30-AUG-08:62 | 4640.27 | 30-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.609259E+09 | 0.154131E+09 | 71.27 | 0.499069E+09 | 0.110191E+09 | 0.00 | 1.00 | 01-SEP-08:62 | 0.00 | 01-SEP-00:05 | 21527.00 | 01-SEP-08:62 | 11368.98 | 01-SEP-08:62 | 10158.02 | 01-SEP-08:62 | 4551.04 | 01-SEP-08:62 | 0.00 | 01-SEP-00:05 |
October | 28159858.98 | 7745122.14 | 9.00 | 26639548.82 | 1520310.16 | 0.00 | 0.22 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 | 1706.76 | 19-OCT-15:00 | 1625.56 | 19-OCT-15:00 | 136.08 | 22-OCT-14:10 | 466.64 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.167371E+11 | 0.410950E+10 | 954.21 | 0.120856E+11 | 0.465147E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.626389E+10 | 0.151288E+10 | 288.74 | 0.435392E+10 | 0.190997E+10 | 0.00 | 1.00 | 0.00 | 22878.48 | 14694.77 | 11946.10 | 4906.01 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_10:10 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 | 0.00 | 01-MAR-00:05 |
April | 22715722.20 | 6457491.15 | 2.83 | 19707382.68 | 3008339.51 | 0.00 | 0.30 | 23-APR-15:00 | 0.00 | 01-APR-00:10 | 3009.41 | 23-APR-15:00 | 2610.42 | 23-APR-16:00 | 411.10 | 23-APR-15:00 | 852.36 | 23-APR-16:00 | 0.00 | 01-APR-00:10 |
May | 0.126266E+10 | 0.338656E+09 | 97.87 | 0.109353E+10 | 0.169134E+09 | 0.00 | 0.76 | 25-MAY-15:00 | 0.00 | 01-MAY-00:10 | 8893.36 | 25-MAY-15:00 | 7203.56 | 18-MAY-15:00 | 2674.20 | 26-MAY-08:62 | 2281.89 | 25-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.376246E+10 | 0.951244E+09 | 197.63 | 0.276843E+10 | 0.994036E+09 | 0.00 | 1.00 | 25-JUN-09:01 | 0.00 | 01-JUN-00:10 | 27805.01 | 30-JUN-08:61 | 17619.69 | 27-JUN-08:62 | 13075.92 | 30-JUN-08:03 | 5914.58 | 30-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.622603E+10 | 0.153736E+10 | 278.09 | 0.437987E+10 | 0.184616E+10 | 0.00 | 1.00 | 01-JUL-08:62 | 0.00 | 01-JUL-00:05 | 27654.01 | 23-JUL-09:01 | 17665.92 | 25-JUL-08:62 | 14648.47 | 05-JUL-08:62 | 5872.63 | 23-JUL-09:01 | 0.00 | 01-JUL-00:05 |
August | 0.423320E+10 | 0.105326E+10 | 233.29 | 0.298034E+10 | 0.125286E+10 | 0.00 | 1.00 | 08-AUG-08:62 | 0.00 | 01-AUG-00:10 | 26516.81 | 09-AUG-08:62 | 14889.46 | 09-AUG-08:62 | 11627.35 | 09-AUG-08:62 | 5570.73 | 09-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.492704E+09 | 0.125639E+09 | 50.53 | 0.400842E+09 | 91862120.93 | 0.00 | 1.00 | 01-SEP-08:62 | 0.00 | 01-SEP-00:05 | 16395.05 | 01-SEP-08:62 | 8418.29 | 01-SEP-08:62 | 7976.76 | 01-SEP-08:62 | 3470.01 | 01-SEP-08:62 | 0.00 | 01-SEP-00:05 |
October | 8650782.19 | 2429314.46 | 5.17 | 8295430.61 | 355351.58 | 0.00 | 0.13 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 | 1246.97 | 19-OCT-15:00 | 1200.30 | 19-OCT-15:00 | 54.20 | 19-OCT-14:30 | 348.35 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.160084E+11 | 0.401504E+10 | 865.42 | 0.116510E+11 | 0.435742E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.622603E+10 | 0.153736E+10 | 278.09 | 0.437987E+10 | 0.184616E+10 | 0.00 | 1.00 | 0.00 | 27805.01 | 17665.92 | 14648.47 | 5914.58 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 119.65 | 113.43 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 168.94 | 93.85 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 152.75 | 76.14 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 149.60 | 51.12 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 134.03 | 30.20 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.63 | 20.86 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.74 | 19.21 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 149.00 | 22.93 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 148.87 | 36.75 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 114.77 | 52.76 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 92.28 | 72.68 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 86.01 | 109.42 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.92 | 58.13 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 86.01 | 19.21 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 168.94 | 113.43 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 119.65 | 113.43 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 168.94 | 93.85 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 152.75 | 76.14 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 149.60 | 51.12 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 134.03 | 30.20 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.63 | 20.86 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.74 | 19.21 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 149.00 | 22.93 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 148.87 | 36.75 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 114.77 | 52.76 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 92.28 | 72.68 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 86.01 | 109.42 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.92 | 58.13 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 86.01 | 19.21 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 168.94 | 113.43 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 119.65 | 113.43 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 168.94 | 93.85 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 152.75 | 76.14 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 149.60 | 51.12 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 134.03 | 30.20 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.63 | 20.86 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.74 | 19.21 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 149.00 | 22.93 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 148.87 | 36.75 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 114.77 | 52.76 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 92.28 | 72.68 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 86.01 | 109.42 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.92 | 58.13 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 86.01 | 19.21 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 168.94 | 113.43 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 119.65 | 113.43 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 168.94 | 93.85 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 152.75 | 76.14 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 149.60 | 51.12 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 134.03 | 30.20 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.63 | 20.86 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.74 | 19.21 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 149.00 | 22.93 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 148.87 | 36.75 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 114.77 | 52.76 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 92.28 | 72.68 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 86.01 | 109.42 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.92 | 58.13 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 86.01 | 19.21 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 168.94 | 113.43 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_DOOR_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 159.76 | 111.00 | 48.75 | 144.39 | 134.86 | 0.00 | 0.00 | 0.00 |
February | 202.56 | 136.72 | 65.84 | 203.69 | 111.63 | 0.00 | 0.00 | 0.00 |
March | 178.90 | 113.28 | 65.62 | 184.02 | 90.62 | 0.00 | 0.00 | 0.00 |
April | 162.39 | 88.35 | 74.04 | 180.12 | 60.92 | 0.00 | 0.00 | 0.00 |
May | 136.59 | 46.99 | 89.60 | 161.25 | 36.07 | 0.00 | 0.00 | 0.00 |
June | 122.57 | 32.97 | 89.60 | 152.24 | 24.96 | 0.00 | 0.00 | 0.00 |
July | 134.03 | 42.78 | 91.25 | 172.75 | 23.01 | 0.00 | 0.00 | 0.00 |
August | 143.05 | 60.08 | 82.97 | 179.16 | 27.42 | 0.00 | 0.00 | 0.00 |
September | 153.03 | 81.61 | 71.42 | 179.15 | 43.86 | 0.00 | 0.00 | 0.00 |
October | 130.44 | 76.70 | 53.73 | 138.21 | 62.90 | 0.00 | 0.00 | 0.00 |
November | 115.95 | 72.67 | 43.28 | 111.29 | 86.49 | 0.00 | 0.00 | 0.00 |
December | 123.33 | 80.74 | 42.59 | 103.89 | 130.03 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 146.52 | 78.29 | 68.23 | 158.85 | 69.22 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 115.95 | 32.97 | 42.59 | 103.89 | 23.01 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 202.56 | 136.72 | 91.25 | 203.69 | 134.86 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_DOOR_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 159.76 | 111.00 | 48.75 | 144.39 | 134.86 | 0.00 | 0.00 | 0.00 |
February | 202.56 | 136.72 | 65.84 | 203.69 | 111.63 | 0.00 | 0.00 | 0.00 |
March | 178.90 | 113.28 | 65.62 | 184.02 | 90.62 | 0.00 | 0.00 | 0.00 |
April | 162.39 | 88.35 | 74.04 | 180.12 | 60.92 | 0.00 | 0.00 | 0.00 |
May | 136.59 | 46.99 | 89.60 | 161.25 | 36.07 | 0.00 | 0.00 | 0.00 |
June | 122.57 | 32.97 | 89.60 | 152.24 | 24.96 | 0.00 | 0.00 | 0.00 |
July | 134.03 | 42.78 | 91.25 | 172.75 | 23.01 | 0.00 | 0.00 | 0.00 |
August | 143.05 | 60.08 | 82.97 | 179.16 | 27.42 | 0.00 | 0.00 | 0.00 |
September | 153.03 | 81.61 | 71.42 | 179.15 | 43.86 | 0.00 | 0.00 | 0.00 |
October | 130.44 | 76.70 | 53.73 | 138.21 | 62.90 | 0.00 | 0.00 | 0.00 |
November | 115.95 | 72.67 | 43.28 | 111.29 | 86.49 | 0.00 | 0.00 | 0.00 |
December | 123.33 | 80.74 | 42.59 | 103.89 | 130.03 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 146.52 | 78.29 | 68.23 | 158.85 | 69.22 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 115.95 | 32.97 | 42.59 | 103.89 | 23.01 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 202.56 | 136.72 | 91.25 | 203.69 | 134.86 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 118.51 | 116.74 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 167.52 | 97.15 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 151.48 | 79.33 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 148.67 | 53.31 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 133.63 | 30.86 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.14 | 21.33 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.40 | 19.51 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.64 | 23.31 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 148.78 | 37.16 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 114.50 | 53.83 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 91.32 | 75.62 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.04 | 112.83 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.20 | 59.92 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.04 | 19.51 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 167.52 | 116.74 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 118.51 | 116.74 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 167.52 | 97.15 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 151.48 | 79.33 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 148.67 | 53.31 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 133.63 | 30.86 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.14 | 21.33 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.40 | 19.51 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.64 | 23.31 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 148.78 | 37.16 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 114.50 | 53.83 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 91.32 | 75.62 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.04 | 112.83 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.20 | 59.92 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.04 | 19.51 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 167.52 | 116.74 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_DOOR
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 159.76 | 111.00 | 48.75 | 143.04 | 138.76 | 0.00 | 0.00 | 0.00 |
February | 202.56 | 136.72 | 65.84 | 202.02 | 115.54 | 0.00 | 0.00 | 0.00 |
March | 178.90 | 113.28 | 65.62 | 182.51 | 94.40 | 0.00 | 0.00 | 0.00 |
April | 162.39 | 88.35 | 74.04 | 179.02 | 63.50 | 0.00 | 0.00 | 0.00 |
May | 136.59 | 46.99 | 89.60 | 160.78 | 36.84 | 0.00 | 0.00 | 0.00 |
June | 122.57 | 32.97 | 89.60 | 151.67 | 25.52 | 0.00 | 0.00 | 0.00 |
July | 134.03 | 42.78 | 91.25 | 172.35 | 23.36 | 0.00 | 0.00 | 0.00 |
August | 143.05 | 60.08 | 82.97 | 178.76 | 27.86 | 0.00 | 0.00 | 0.00 |
September | 153.03 | 81.61 | 71.42 | 179.05 | 44.32 | 0.00 | 0.00 | 0.00 |
October | 130.44 | 76.70 | 53.73 | 137.90 | 64.15 | 0.00 | 0.00 | 0.00 |
November | 115.95 | 72.67 | 43.28 | 110.15 | 89.95 | 0.00 | 0.00 | 0.00 |
December | 123.33 | 80.74 | 42.59 | 102.74 | 134.05 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 146.52 | 78.29 | 68.23 | 158.01 | 71.33 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 115.95 | 32.97 | 42.59 | 102.74 | 23.36 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 202.56 | 136.72 | 91.25 | 202.02 | 138.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 118.52 | 114.64 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 167.54 | 95.46 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 151.47 | 77.99 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 148.96 | 51.92 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 133.94 | 30.78 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.06 | 22.02 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 142.97 | 20.75 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.49 | 24.42 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 149.09 | 37.14 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 114.91 | 52.29 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 91.46 | 74.05 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.05 | 110.85 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.27 | 59.21 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.05 | 20.75 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 167.54 | 114.64 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 118.52 | 114.64 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 167.54 | 95.46 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 151.47 | 77.99 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 148.96 | 51.92 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 133.94 | 30.78 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.06 | 22.02 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 142.97 | 20.75 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.49 | 24.42 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 149.09 | 37.14 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 114.91 | 52.29 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 91.46 | 74.05 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.05 | 110.85 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.27 | 59.21 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.05 | 20.75 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 167.54 | 114.64 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_DOOR
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 158.88 | 110.40 | 48.49 | 142.29 | 135.54 | 0.00 | 0.00 | 0.00 |
February | 201.46 | 135.97 | 65.48 | 200.95 | 112.93 | 0.00 | 0.00 | 0.00 |
March | 177.93 | 112.66 | 65.27 | 181.51 | 92.31 | 0.00 | 0.00 | 0.00 |
April | 161.50 | 87.87 | 73.64 | 178.39 | 61.52 | 0.00 | 0.00 | 0.00 |
May | 135.85 | 46.73 | 89.11 | 160.27 | 36.55 | 0.00 | 0.00 | 0.00 |
June | 121.90 | 32.79 | 89.11 | 150.75 | 26.18 | 0.00 | 0.00 | 0.00 |
July | 133.30 | 42.55 | 90.75 | 170.91 | 24.69 | 0.00 | 0.00 | 0.00 |
August | 142.27 | 59.75 | 82.52 | 177.59 | 29.01 | 0.00 | 0.00 | 0.00 |
September | 152.19 | 81.17 | 71.02 | 178.45 | 44.05 | 0.00 | 0.00 | 0.00 |
October | 129.72 | 76.28 | 53.44 | 137.64 | 61.98 | 0.00 | 0.00 | 0.00 |
November | 115.32 | 72.28 | 43.04 | 109.72 | 87.62 | 0.00 | 0.00 | 0.00 |
December | 122.66 | 80.30 | 42.36 | 102.20 | 130.99 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 145.72 | 77.86 | 67.86 | 157.23 | 70.10 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 115.32 | 32.79 | 42.36 | 102.20 | 24.69 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 201.46 | 135.97 | 90.75 | 200.95 | 135.54 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 118.62 | 113.91 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 167.67 | 94.76 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 151.59 | 77.36 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 149.16 | 51.27 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 134.13 | 30.44 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.15 | 21.89 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 142.97 | 20.77 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.50 | 24.39 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 149.23 | 36.82 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 115.10 | 51.62 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 91.59 | 73.32 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.13 | 110.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.39 | 58.74 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.13 | 20.77 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 167.67 | 113.91 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 118.62 | 113.91 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 167.67 | 94.76 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 151.59 | 77.36 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 149.16 | 51.27 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 134.13 | 30.44 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.15 | 21.89 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 142.97 | 20.77 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.50 | 24.39 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 149.23 | 36.82 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 115.10 | 51.62 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 91.59 | 73.32 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.13 | 110.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.39 | 58.74 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.13 | 20.77 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 167.67 | 113.91 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_DOOR
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 158.88 | 110.40 | 48.49 | 142.41 | 134.67 | 0.00 | 0.00 | 0.00 |
February | 201.46 | 135.97 | 65.48 | 201.11 | 112.10 | 0.00 | 0.00 | 0.00 |
March | 177.93 | 112.66 | 65.27 | 181.65 | 91.56 | 0.00 | 0.00 | 0.00 |
April | 161.50 | 87.87 | 73.64 | 178.63 | 60.75 | 0.00 | 0.00 | 0.00 |
May | 135.85 | 46.73 | 89.11 | 160.50 | 36.14 | 0.00 | 0.00 | 0.00 |
June | 121.90 | 32.79 | 89.11 | 150.86 | 26.03 | 0.00 | 0.00 | 0.00 |
July | 133.30 | 42.55 | 90.75 | 170.90 | 24.72 | 0.00 | 0.00 | 0.00 |
August | 142.27 | 59.75 | 82.52 | 177.62 | 28.97 | 0.00 | 0.00 | 0.00 |
September | 152.19 | 81.17 | 71.02 | 178.61 | 43.67 | 0.00 | 0.00 | 0.00 |
October | 129.72 | 76.28 | 53.44 | 137.87 | 61.19 | 0.00 | 0.00 | 0.00 |
November | 115.32 | 72.28 | 43.04 | 109.88 | 86.76 | 0.00 | 0.00 | 0.00 |
December | 122.66 | 80.30 | 42.36 | 102.30 | 130.13 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 145.72 | 77.86 | 67.86 | 157.37 | 69.54 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 115.32 | 32.79 | 42.36 | 102.30 | 24.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 201.46 | 135.97 | 90.75 | 201.11 | 134.67 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 118.73 | 113.44 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 167.82 | 94.25 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 151.73 | 76.87 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 149.29 | 50.95 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 134.24 | 30.26 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.26 | 21.73 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.05 | 20.62 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.58 | 24.22 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 149.26 | 36.73 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 115.17 | 51.41 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 91.73 | 72.80 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.23 | 109.64 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.49 | 58.43 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.23 | 20.62 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 167.82 | 113.44 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 118.73 | 113.44 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 167.82 | 94.25 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 151.73 | 76.87 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 149.29 | 50.95 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 134.24 | 30.26 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.26 | 21.73 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.05 | 20.62 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.58 | 24.22 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 149.26 | 36.73 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 115.17 | 51.41 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 91.73 | 72.80 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.23 | 109.64 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.49 | 58.43 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.23 | 20.62 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 167.82 | 113.44 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_DOOR
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 158.88 | 110.40 | 48.49 | 142.54 | 134.12 | 0.00 | 0.00 | 0.00 |
February | 201.46 | 135.97 | 65.48 | 201.29 | 111.49 | 0.00 | 0.00 | 0.00 |
March | 177.93 | 112.66 | 65.27 | 181.83 | 90.97 | 0.00 | 0.00 | 0.00 |
April | 161.50 | 87.87 | 73.64 | 178.79 | 60.37 | 0.00 | 0.00 | 0.00 |
May | 135.85 | 46.73 | 89.11 | 160.62 | 35.93 | 0.00 | 0.00 | 0.00 |
June | 121.90 | 32.79 | 89.11 | 150.98 | 25.84 | 0.00 | 0.00 | 0.00 |
July | 133.30 | 42.55 | 90.75 | 171.00 | 24.53 | 0.00 | 0.00 | 0.00 |
August | 142.27 | 59.75 | 82.52 | 177.70 | 28.78 | 0.00 | 0.00 | 0.00 |
September | 152.19 | 81.17 | 71.02 | 178.64 | 43.57 | 0.00 | 0.00 | 0.00 |
October | 129.72 | 76.28 | 53.44 | 137.96 | 60.95 | 0.00 | 0.00 | 0.00 |
November | 115.32 | 72.28 | 43.04 | 110.05 | 86.13 | 0.00 | 0.00 | 0.00 |
December | 122.66 | 80.30 | 42.36 | 102.42 | 129.55 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 145.72 | 77.86 | 67.86 | 157.50 | 69.18 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 115.32 | 32.79 | 42.36 | 102.42 | 24.53 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 201.46 | 135.97 | 90.75 | 201.29 | 134.12 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 119.57 | 111.61 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 168.85 | 92.57 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 152.55 | 75.40 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 149.45 | 50.52 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 133.84 | 30.19 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.19 | 21.44 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.02 | 20.23 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.58 | 23.85 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 148.75 | 37.06 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 115.05 | 51.53 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 92.35 | 71.36 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.96 | 107.72 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.74 | 57.64 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.96 | 20.23 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 168.85 | 111.61 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 119.57 | 111.61 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 168.85 | 92.57 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 152.55 | 75.40 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 149.45 | 50.52 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 133.84 | 30.19 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.19 | 21.44 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.02 | 20.23 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.58 | 23.85 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 148.75 | 37.06 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 115.05 | 51.53 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 92.35 | 71.36 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.96 | 107.72 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.74 | 57.64 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.96 | 20.23 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 168.85 | 111.61 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 119.57 | 111.61 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 168.85 | 92.57 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 152.55 | 75.40 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 149.45 | 50.52 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 133.84 | 30.19 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.19 | 21.44 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.02 | 20.23 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.58 | 23.85 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 148.75 | 37.06 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 115.05 | 51.53 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 92.35 | 71.36 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.96 | 107.72 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.74 | 57.64 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.96 | 20.23 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 168.85 | 111.61 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 119.57 | 111.61 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 168.85 | 92.57 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 152.55 | 75.40 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 149.45 | 50.52 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 133.84 | 30.19 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.19 | 21.44 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.02 | 20.23 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.58 | 23.85 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 148.75 | 37.06 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 115.05 | 51.53 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 92.35 | 71.36 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.96 | 107.72 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.74 | 57.64 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.96 | 20.23 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 168.85 | 111.61 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_DOOR_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 158.88 | 110.40 | 48.49 | 143.51 | 132.00 | 0.00 | 0.00 | 0.00 |
February | 201.46 | 135.97 | 65.48 | 202.47 | 109.55 | 0.00 | 0.00 | 0.00 |
March | 177.93 | 112.66 | 65.27 | 182.77 | 89.26 | 0.00 | 0.00 | 0.00 |
April | 161.50 | 87.87 | 73.64 | 178.97 | 59.88 | 0.00 | 0.00 | 0.00 |
May | 135.85 | 46.73 | 89.11 | 160.14 | 35.85 | 0.00 | 0.00 | 0.00 |
June | 121.90 | 32.79 | 89.11 | 150.90 | 25.49 | 0.00 | 0.00 | 0.00 |
July | 133.30 | 42.55 | 90.75 | 170.96 | 24.07 | 0.00 | 0.00 | 0.00 |
August | 142.27 | 59.75 | 82.52 | 177.69 | 28.34 | 0.00 | 0.00 | 0.00 |
September | 152.19 | 81.17 | 71.02 | 178.03 | 43.97 | 0.00 | 0.00 | 0.00 |
October | 129.72 | 76.28 | 53.44 | 137.80 | 61.10 | 0.00 | 0.00 | 0.00 |
November | 115.32 | 72.28 | 43.04 | 110.77 | 84.46 | 0.00 | 0.00 | 0.00 |
December | 122.66 | 80.30 | 42.36 | 103.26 | 127.33 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 145.72 | 77.86 | 67.86 | 157.78 | 68.27 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 115.32 | 32.79 | 42.36 | 103.26 | 24.07 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 201.46 | 135.97 | 90.75 | 202.47 | 132.00 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_DOOR_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 158.88 | 110.40 | 48.49 | 143.51 | 132.00 | 0.00 | 0.00 | 0.00 |
February | 201.46 | 135.97 | 65.48 | 202.47 | 109.55 | 0.00 | 0.00 | 0.00 |
March | 177.93 | 112.66 | 65.27 | 182.77 | 89.26 | 0.00 | 0.00 | 0.00 |
April | 161.50 | 87.87 | 73.64 | 178.97 | 59.88 | 0.00 | 0.00 | 0.00 |
May | 135.85 | 46.73 | 89.11 | 160.14 | 35.85 | 0.00 | 0.00 | 0.00 |
June | 121.90 | 32.79 | 89.11 | 150.90 | 25.49 | 0.00 | 0.00 | 0.00 |
July | 133.30 | 42.55 | 90.75 | 170.96 | 24.07 | 0.00 | 0.00 | 0.00 |
August | 142.27 | 59.75 | 82.52 | 177.69 | 28.34 | 0.00 | 0.00 | 0.00 |
September | 152.19 | 81.17 | 71.02 | 178.03 | 43.97 | 0.00 | 0.00 | 0.00 |
October | 129.72 | 76.28 | 53.44 | 137.80 | 61.10 | 0.00 | 0.00 | 0.00 |
November | 115.32 | 72.28 | 43.04 | 110.77 | 84.46 | 0.00 | 0.00 | 0.00 |
December | 122.66 | 80.30 | 42.36 | 103.26 | 127.33 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 145.72 | 77.86 | 67.86 | 157.78 | 68.27 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 115.32 | 32.79 | 42.36 | 103.26 | 24.07 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 201.46 | 135.97 | 90.75 | 202.47 | 132.00 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 119.14 | 112.32 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 168.37 | 93.11 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 152.20 | 75.75 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 149.71 | 49.97 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 134.51 | 29.50 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.46 | 21.08 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.06 | 20.03 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.58 | 23.61 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 149.33 | 36.08 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 115.43 | 50.61 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 92.12 | 71.66 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.60 | 108.48 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.77 | 57.53 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.60 | 20.03 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 168.37 | 112.32 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 119.14 | 112.32 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 168.37 | 93.11 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 152.20 | 75.75 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 149.71 | 49.97 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 134.51 | 29.50 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.46 | 21.08 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.06 | 20.03 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.58 | 23.61 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 149.33 | 36.08 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 115.43 | 50.61 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 92.12 | 71.66 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.60 | 108.48 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.77 | 57.53 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.60 | 20.03 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 168.37 | 112.32 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_DOOR
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 158.88 | 110.40 | 48.49 | 143.04 | 132.79 | 0.00 | 0.00 | 0.00 |
February | 201.46 | 135.97 | 65.48 | 201.94 | 110.14 | 0.00 | 0.00 | 0.00 |
March | 177.93 | 112.66 | 65.27 | 182.39 | 89.65 | 0.00 | 0.00 | 0.00 |
April | 161.50 | 87.87 | 73.64 | 179.30 | 59.21 | 0.00 | 0.00 | 0.00 |
May | 135.85 | 46.73 | 89.11 | 160.96 | 35.04 | 0.00 | 0.00 | 0.00 |
June | 121.90 | 32.79 | 89.11 | 151.23 | 25.06 | 0.00 | 0.00 | 0.00 |
July | 133.30 | 42.55 | 90.75 | 171.01 | 23.84 | 0.00 | 0.00 | 0.00 |
August | 142.27 | 59.75 | 82.52 | 177.72 | 28.05 | 0.00 | 0.00 | 0.00 |
September | 152.19 | 81.17 | 71.02 | 178.74 | 42.80 | 0.00 | 0.00 | 0.00 |
October | 129.72 | 76.28 | 53.44 | 138.27 | 60.00 | 0.00 | 0.00 | 0.00 |
November | 115.32 | 72.28 | 43.04 | 110.51 | 84.79 | 0.00 | 0.00 | 0.00 |
December | 122.66 | 80.30 | 42.36 | 102.86 | 128.18 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 145.72 | 77.86 | 67.86 | 157.84 | 68.12 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 115.32 | 32.79 | 42.36 | 102.86 | 23.84 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 201.46 | 135.97 | 90.75 | 201.94 | 132.79 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 119.17 | 112.23 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 168.41 | 92.97 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 152.26 | 75.55 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 149.95 | 49.50 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 134.87 | 29.08 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.72 | 20.81 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.16 | 19.92 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.69 | 23.46 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 149.61 | 35.61 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 115.65 | 50.10 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 92.19 | 71.42 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.62 | 108.37 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.92 | 57.27 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.62 | 19.92 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 168.41 | 112.23 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 119.17 | 112.23 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 168.41 | 92.97 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 152.26 | 75.55 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 149.95 | 49.50 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 134.87 | 29.08 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 126.72 | 20.81 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.16 | 19.92 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.69 | 23.46 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 149.61 | 35.61 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 115.65 | 50.10 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 92.19 | 71.42 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.62 | 108.37 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 131.92 | 57.27 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.62 | 19.92 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 168.41 | 112.23 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_DOOR
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 158.88 | 110.40 | 48.49 | 143.07 | 132.68 | 0.00 | 0.00 | 0.00 |
February | 201.46 | 135.97 | 65.48 | 202.00 | 109.97 | 0.00 | 0.00 | 0.00 |
March | 177.93 | 112.66 | 65.27 | 182.46 | 89.42 | 0.00 | 0.00 | 0.00 |
April | 161.50 | 87.87 | 73.64 | 179.58 | 58.66 | 0.00 | 0.00 | 0.00 |
May | 135.85 | 46.73 | 89.11 | 161.39 | 34.53 | 0.00 | 0.00 | 0.00 |
June | 121.90 | 32.79 | 89.11 | 151.54 | 24.75 | 0.00 | 0.00 | 0.00 |
July | 133.30 | 42.55 | 90.75 | 171.13 | 23.71 | 0.00 | 0.00 | 0.00 |
August | 142.27 | 59.75 | 82.52 | 177.84 | 27.87 | 0.00 | 0.00 | 0.00 |
September | 152.19 | 81.17 | 71.02 | 179.07 | 42.24 | 0.00 | 0.00 | 0.00 |
October | 129.72 | 76.28 | 53.44 | 138.53 | 59.39 | 0.00 | 0.00 | 0.00 |
November | 115.32 | 72.28 | 43.04 | 110.60 | 84.50 | 0.00 | 0.00 | 0.00 |
December | 122.66 | 80.30 | 42.36 | 102.89 | 128.05 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 145.72 | 77.86 | 67.86 | 158.02 | 67.81 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 115.32 | 32.79 | 42.36 | 102.89 | 23.71 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 201.46 | 135.97 | 90.75 | 202.00 | 132.68 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 119.31 | 111.53 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 168.62 | 92.13 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 152.52 | 74.57 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 150.42 | 48.39 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 135.49 | 28.29 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 127.20 | 20.29 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.37 | 19.66 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.90 | 23.11 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 150.00 | 34.91 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 115.99 | 49.19 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 92.43 | 70.44 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.75 | 107.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 132.23 | 56.53 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.75 | 19.66 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 168.62 | 111.53 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 119.31 | 111.53 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 168.62 | 92.13 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 152.52 | 74.57 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 150.42 | 48.39 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 135.49 | 28.29 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 127.20 | 20.29 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.37 | 19.66 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 148.90 | 23.11 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 150.00 | 34.91 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 115.99 | 49.19 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 92.43 | 70.44 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 85.75 | 107.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 132.23 | 56.53 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 85.75 | 19.66 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 168.62 | 111.53 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_DOOR
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 158.88 | 110.40 | 48.49 | 143.24 | 131.85 | 0.00 | 0.00 | 0.00 |
February | 201.46 | 135.97 | 65.48 | 202.25 | 108.98 | 0.00 | 0.00 | 0.00 |
March | 177.93 | 112.66 | 65.27 | 182.77 | 88.25 | 0.00 | 0.00 | 0.00 |
April | 161.50 | 87.87 | 73.64 | 180.15 | 57.34 | 0.00 | 0.00 | 0.00 |
May | 135.85 | 46.73 | 89.11 | 162.13 | 33.60 | 0.00 | 0.00 | 0.00 |
June | 121.90 | 32.79 | 89.11 | 152.11 | 24.13 | 0.00 | 0.00 | 0.00 |
July | 133.30 | 42.55 | 90.75 | 171.39 | 23.40 | 0.00 | 0.00 | 0.00 |
August | 142.27 | 59.75 | 82.52 | 178.10 | 27.47 | 0.00 | 0.00 | 0.00 |
September | 152.19 | 81.17 | 71.02 | 179.53 | 41.42 | 0.00 | 0.00 | 0.00 |
October | 129.72 | 76.28 | 53.44 | 138.94 | 58.32 | 0.00 | 0.00 | 0.00 |
November | 115.32 | 72.28 | 43.04 | 110.90 | 83.34 | 0.00 | 0.00 | 0.00 |
December | 122.66 | 80.30 | 42.36 | 103.05 | 127.14 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 145.72 | 77.86 | 67.86 | 158.39 | 66.93 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 115.32 | 32.79 | 42.36 | 103.05 | 23.40 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 201.46 | 135.97 | 90.75 | 202.25 | 131.85 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 120.22 | 107.91 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 169.67 | 88.34 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 153.60 | 70.28 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 151.75 | 44.28 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 136.98 | 25.80 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 128.22 | 18.63 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.81 | 18.63 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 149.42 | 21.86 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 150.86 | 32.79 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 116.92 | 46.13 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 93.33 | 66.51 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 86.54 | 103.82 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 133.17 | 53.61 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 86.54 | 18.63 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 169.67 | 107.91 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.89 | 92.34 | 40.56 | 120.22 | 107.91 | 0.00 | 0.00 | 0.00 |
February | 168.50 | 113.73 | 54.77 | 169.67 | 88.34 | 0.00 | 0.00 | 0.00 |
March | 148.82 | 94.23 | 54.59 | 153.60 | 70.28 | 0.00 | 0.00 | 0.00 |
April | 135.08 | 73.49 | 61.59 | 151.75 | 44.28 | 0.00 | 0.00 | 0.00 |
May | 113.62 | 39.09 | 74.53 | 136.98 | 25.80 | 0.00 | 0.00 | 0.00 |
June | 101.96 | 27.42 | 74.53 | 128.22 | 18.63 | 0.00 | 0.00 | 0.00 |
July | 111.50 | 35.59 | 75.91 | 143.81 | 18.63 | 0.00 | 0.00 | 0.00 |
August | 118.99 | 49.97 | 69.02 | 149.42 | 21.86 | 0.00 | 0.00 | 0.00 |
September | 127.30 | 67.89 | 59.41 | 150.86 | 32.79 | 0.00 | 0.00 | 0.00 |
October | 108.50 | 63.81 | 44.70 | 116.92 | 46.13 | 0.00 | 0.00 | 0.00 |
November | 96.45 | 60.45 | 36.00 | 93.33 | 66.51 | 0.00 | 0.00 | 0.00 |
December | 102.59 | 67.17 | 35.43 | 86.54 | 103.82 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 121.88 | 65.12 | 56.76 | 133.17 | 53.61 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 96.45 | 27.42 | 35.43 | 86.54 | 18.63 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 168.50 | 113.73 | 75.91 | 169.67 | 107.91 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_DOOR
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 158.88 | 110.40 | 48.49 | 144.35 | 127.51 | 0.00 | 0.00 | 0.00 |
February | 201.46 | 135.97 | 65.48 | 203.53 | 104.46 | 0.00 | 0.00 | 0.00 |
March | 177.93 | 112.66 | 65.27 | 184.10 | 83.14 | 0.00 | 0.00 | 0.00 |
April | 161.50 | 87.87 | 73.64 | 181.75 | 52.48 | 0.00 | 0.00 | 0.00 |
May | 135.85 | 46.73 | 89.11 | 163.91 | 30.66 | 0.00 | 0.00 | 0.00 |
June | 121.90 | 32.79 | 89.11 | 153.32 | 22.16 | 0.00 | 0.00 | 0.00 |
July | 133.30 | 42.55 | 90.75 | 171.92 | 22.18 | 0.00 | 0.00 | 0.00 |
August | 142.27 | 59.75 | 82.52 | 178.72 | 25.98 | 0.00 | 0.00 | 0.00 |
September | 152.19 | 81.17 | 71.02 | 180.56 | 38.91 | 0.00 | 0.00 | 0.00 |
October | 129.72 | 76.28 | 53.44 | 140.07 | 54.70 | 0.00 | 0.00 | 0.00 |
November | 115.32 | 72.28 | 43.04 | 111.99 | 78.68 | 0.00 | 0.00 | 0.00 |
December | 122.66 | 80.30 | 42.36 | 104.00 | 122.62 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 145.72 | 77.86 | 67.86 | 159.52 | 63.46 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 115.32 | 32.79 | 42.36 | 104.00 | 22.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 201.46 | 135.97 | 90.75 | 203.53 | 127.51 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.320462E+09 | 0.303815E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.408698E+09 | 0.227036E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.409138E+09 | 0.203935E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.387754E+09 | 0.132500E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.358982E+09 | 80887551.09 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.328236E+09 | 54071860.35 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.385005E+09 | 51456714.02 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.399071E+09 | 61409179.50 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.385880E+09 | 95268447.13 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.307391E+09 | 0.141304E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.239181E+09 | 0.188395E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.230371E+09 | 0.293079E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.416017E+10 | 0.183316E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.230371E+09 | 51456714.02 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.409138E+09 | 0.303815E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.320462E+09 | 0.303815E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.408698E+09 | 0.227036E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.409138E+09 | 0.203935E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.387754E+09 | 0.132500E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.358982E+09 | 80887551.09 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.328236E+09 | 54071860.35 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.385005E+09 | 51456714.02 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.399071E+09 | 61409179.50 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.385880E+09 | 95268447.13 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.307391E+09 | 0.141304E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.239181E+09 | 0.188395E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.230371E+09 | 0.293079E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.416017E+10 | 0.183316E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.230371E+09 | 51456714.02 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.409138E+09 | 0.303815E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.320462E+09 | 0.303815E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.408698E+09 | 0.227036E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.409138E+09 | 0.203935E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.387754E+09 | 0.132500E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.358982E+09 | 80887551.09 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.328236E+09 | 54071860.35 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.385005E+09 | 51456714.02 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.399071E+09 | 61409179.50 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.385880E+09 | 95268447.13 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.307391E+09 | 0.141304E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.239181E+09 | 0.188395E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.230371E+09 | 0.293079E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.416017E+10 | 0.183316E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.230371E+09 | 51456714.02 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.409138E+09 | 0.303815E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.320462E+09 | 0.303815E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.408698E+09 | 0.227036E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.409138E+09 | 0.203935E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.387754E+09 | 0.132500E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.358982E+09 | 80887551.09 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.328236E+09 | 54071860.35 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.385005E+09 | 51456714.02 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.399071E+09 | 61409179.50 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.385880E+09 | 95268447.13 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.307391E+09 | 0.141304E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.239181E+09 | 0.188395E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.230371E+09 | 0.293079E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.416017E+10 | 0.183316E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.230371E+09 | 51456714.02 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.409138E+09 | 0.303815E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_DOOR_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.427891E+09 | 0.297308E+09 | 0.130583E+09 | 0.386745E+09 | 0.361197E+09 |
February | 0.490039E+09 | 0.330757E+09 | 0.159282E+09 | 0.492775E+09 | 0.270067E+09 |
March | 0.479176E+09 | 0.303409E+09 | 0.175766E+09 | 0.492887E+09 | 0.242717E+09 |
April | 0.420920E+09 | 0.229004E+09 | 0.191916E+09 | 0.466867E+09 | 0.157894E+09 |
May | 0.365848E+09 | 0.125862E+09 | 0.239986E+09 | 0.431880E+09 | 96600446.17 |
June | 0.317696E+09 | 85454633.93 | 0.232242E+09 | 0.394618E+09 | 64695302.47 |
July | 0.358998E+09 | 0.114595E+09 | 0.244403E+09 | 0.462690E+09 | 61630202.27 |
August | 0.383143E+09 | 0.160910E+09 | 0.222233E+09 | 0.479864E+09 | 73433806.68 |
September | 0.396653E+09 | 0.211545E+09 | 0.185108E+09 | 0.464347E+09 | 0.113681E+09 |
October | 0.349362E+09 | 0.205444E+09 | 0.143918E+09 | 0.370182E+09 | 0.168465E+09 |
November | 0.300552E+09 | 0.188372E+09 | 0.112180E+09 | 0.288455E+09 | 0.224178E+09 |
December | 0.330334E+09 | 0.216267E+09 | 0.114067E+09 | 0.278254E+09 | 0.348261E+09 |
Annual Sum or Average | 0.462061E+10 | 0.246893E+10 | 0.215168E+10 | 0.500956E+10 | 0.218282E+10 |
Minimum of Months | 0.300552E+09 | 85454633.93 | 0.112180E+09 | 0.278254E+09 | 61630202.27 |
Maximum of Months | 0.490039E+09 | 0.330757E+09 | 0.244403E+09 | 0.492887E+09 | 0.361197E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_DOOR_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.427891E+09 | 0.297308E+09 | 0.130583E+09 | 0.386745E+09 | 0.361197E+09 |
February | 0.490039E+09 | 0.330757E+09 | 0.159282E+09 | 0.492775E+09 | 0.270067E+09 |
March | 0.479176E+09 | 0.303409E+09 | 0.175766E+09 | 0.492887E+09 | 0.242717E+09 |
April | 0.420920E+09 | 0.229004E+09 | 0.191916E+09 | 0.466867E+09 | 0.157894E+09 |
May | 0.365848E+09 | 0.125862E+09 | 0.239986E+09 | 0.431880E+09 | 96600446.17 |
June | 0.317696E+09 | 85454633.93 | 0.232242E+09 | 0.394618E+09 | 64695302.47 |
July | 0.358998E+09 | 0.114595E+09 | 0.244403E+09 | 0.462690E+09 | 61630202.27 |
August | 0.383143E+09 | 0.160910E+09 | 0.222233E+09 | 0.479864E+09 | 73433806.68 |
September | 0.396653E+09 | 0.211545E+09 | 0.185108E+09 | 0.464347E+09 | 0.113681E+09 |
October | 0.349362E+09 | 0.205444E+09 | 0.143918E+09 | 0.370182E+09 | 0.168465E+09 |
November | 0.300552E+09 | 0.188372E+09 | 0.112180E+09 | 0.288455E+09 | 0.224178E+09 |
December | 0.330334E+09 | 0.216267E+09 | 0.114067E+09 | 0.278254E+09 | 0.348261E+09 |
Annual Sum or Average | 0.462061E+10 | 0.246893E+10 | 0.215168E+10 | 0.500956E+10 | 0.218282E+10 |
Minimum of Months | 0.300552E+09 | 85454633.93 | 0.112180E+09 | 0.278254E+09 | 61630202.27 |
Maximum of Months | 0.490039E+09 | 0.330757E+09 | 0.244403E+09 | 0.492887E+09 | 0.361197E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.317408E+09 | 0.312677E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.405269E+09 | 0.235032E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.405722E+09 | 0.212470E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.385364E+09 | 0.138180E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.357925E+09 | 82644507.96 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.326961E+09 | 55294716.78 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.384071E+09 | 52247530.17 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.398128E+09 | 62429754.24 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.385639E+09 | 96308951.45 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.306673E+09 | 0.144180E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.236699E+09 | 0.195998E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.227776E+09 | 0.302200E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.413763E+10 | 0.188966E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.227776E+09 | 52247530.17 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.405722E+09 | 0.312677E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.317408E+09 | 0.312677E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.405269E+09 | 0.235032E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.405722E+09 | 0.212470E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.385364E+09 | 0.138180E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.357925E+09 | 82644507.96 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.326961E+09 | 55294716.78 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.384071E+09 | 52247530.17 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.398128E+09 | 62429754.24 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.385639E+09 | 96308951.45 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.306673E+09 | 0.144180E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.236699E+09 | 0.195998E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.227776E+09 | 0.302200E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.413763E+10 | 0.188966E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.227776E+09 | 52247530.17 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.405722E+09 | 0.312677E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_DOOR
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.427891E+09 | 0.297308E+09 | 0.130583E+09 | 0.383119E+09 | 0.371668E+09 |
February | 0.490039E+09 | 0.330757E+09 | 0.159282E+09 | 0.488726E+09 | 0.279522E+09 |
March | 0.479176E+09 | 0.303409E+09 | 0.175766E+09 | 0.488828E+09 | 0.252834E+09 |
April | 0.420920E+09 | 0.229004E+09 | 0.191916E+09 | 0.464026E+09 | 0.164598E+09 |
May | 0.365848E+09 | 0.125862E+09 | 0.239986E+09 | 0.430643E+09 | 98671726.66 |
June | 0.317696E+09 | 85454633.93 | 0.232242E+09 | 0.393124E+09 | 66147505.65 |
July | 0.358998E+09 | 0.114595E+09 | 0.244403E+09 | 0.461612E+09 | 62569832.33 |
August | 0.383143E+09 | 0.160910E+09 | 0.222233E+09 | 0.478784E+09 | 74631850.18 |
September | 0.396653E+09 | 0.211545E+09 | 0.185108E+09 | 0.464100E+09 | 0.114886E+09 |
October | 0.349362E+09 | 0.205444E+09 | 0.143918E+09 | 0.369349E+09 | 0.171832E+09 |
November | 0.300552E+09 | 0.188372E+09 | 0.112180E+09 | 0.285509E+09 | 0.233150E+09 |
December | 0.330334E+09 | 0.216267E+09 | 0.114067E+09 | 0.275174E+09 | 0.359028E+09 |
Annual Sum or Average | 0.462061E+10 | 0.246893E+10 | 0.215168E+10 | 0.498299E+10 | 0.224954E+10 |
Minimum of Months | 0.300552E+09 | 85454633.93 | 0.112180E+09 | 0.275174E+09 | 62569832.33 |
Maximum of Months | 0.490039E+09 | 0.330757E+09 | 0.244403E+09 | 0.488828E+09 | 0.371668E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.317455E+09 | 0.307065E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.405315E+09 | 0.230946E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.405701E+09 | 0.208893E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.386097E+09 | 0.134573E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.358734E+09 | 82452612.01 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.326754E+09 | 57071777.09 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.382939E+09 | 55583232.97 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.397705E+09 | 65402653.71 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.386451E+09 | 96262278.97 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.307777E+09 | 0.140041E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.237053E+09 | 0.191948E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.227808E+09 | 0.296904E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.413979E+10 | 0.186714E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.227808E+09 | 55583232.97 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.405701E+09 | 0.307065E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.317455E+09 | 0.307065E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.405315E+09 | 0.230946E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.405701E+09 | 0.208893E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.386097E+09 | 0.134573E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.358734E+09 | 82452612.01 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.326754E+09 | 57071777.09 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.382939E+09 | 55583232.97 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.397705E+09 | 65402653.71 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.386451E+09 | 96262278.97 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.307777E+09 | 0.140041E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.237053E+09 | 0.191948E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.227808E+09 | 0.296904E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.413979E+10 | 0.186714E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.227808E+09 | 55583232.97 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.405701E+09 | 0.307065E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_DOOR
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.425553E+09 | 0.295683E+09 | 0.129870E+09 | 0.381103E+09 | 0.363041E+09 |
February | 0.487361E+09 | 0.328949E+09 | 0.158412E+09 | 0.486133E+09 | 0.273203E+09 |
March | 0.476557E+09 | 0.301751E+09 | 0.174806E+09 | 0.486153E+09 | 0.247249E+09 |
April | 0.418619E+09 | 0.227752E+09 | 0.190867E+09 | 0.462377E+09 | 0.159463E+09 |
May | 0.363849E+09 | 0.125174E+09 | 0.238675E+09 | 0.429255E+09 | 97888340.29 |
June | 0.315960E+09 | 84987668.72 | 0.230973E+09 | 0.390741E+09 | 67856194.89 |
July | 0.357036E+09 | 0.113969E+09 | 0.243067E+09 | 0.457758E+09 | 66130890.77 |
August | 0.381049E+09 | 0.160031E+09 | 0.221018E+09 | 0.475669E+09 | 77697932.37 |
September | 0.394486E+09 | 0.210389E+09 | 0.184096E+09 | 0.462531E+09 | 0.114183E+09 |
October | 0.347452E+09 | 0.204321E+09 | 0.143131E+09 | 0.368658E+09 | 0.166015E+09 |
November | 0.298910E+09 | 0.187343E+09 | 0.111567E+09 | 0.284387E+09 | 0.227119E+09 |
December | 0.328529E+09 | 0.215085E+09 | 0.113444E+09 | 0.273727E+09 | 0.350845E+09 |
Annual Sum or Average | 0.459536E+10 | 0.245544E+10 | 0.213993E+10 | 0.495849E+10 | 0.221069E+10 |
Minimum of Months | 0.298910E+09 | 84987668.72 | 0.111567E+09 | 0.273727E+09 | 66130890.77 |
Maximum of Months | 0.487361E+09 | 0.328949E+09 | 0.243067E+09 | 0.486153E+09 | 0.363041E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.317716E+09 | 0.305098E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.405629E+09 | 0.229248E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.406016E+09 | 0.207206E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.386621E+09 | 0.132891E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.359262E+09 | 81532800.74 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.326992E+09 | 56740810.15 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.382925E+09 | 55639866.80 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.397755E+09 | 65322932.13 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.386806E+09 | 95425447.68 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.308296E+09 | 0.138248E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.237393E+09 | 0.190058E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.228024E+09 | 0.294957E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.414343E+10 | 0.185237E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.228024E+09 | 55639866.80 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.406016E+09 | 0.305098E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.317716E+09 | 0.305098E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.405629E+09 | 0.229248E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.406016E+09 | 0.207206E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.386621E+09 | 0.132891E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.359262E+09 | 81532800.74 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.326992E+09 | 56740810.15 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.382925E+09 | 55639866.80 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.397755E+09 | 65322932.13 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.386806E+09 | 95425447.68 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.308296E+09 | 0.138248E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.237393E+09 | 0.190058E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.228024E+09 | 0.294957E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.414343E+10 | 0.185237E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.228024E+09 | 55639866.80 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.406016E+09 | 0.305098E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_DOOR
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.425553E+09 | 0.295683E+09 | 0.129870E+09 | 0.381421E+09 | 0.360702E+09 |
February | 0.487361E+09 | 0.328949E+09 | 0.158412E+09 | 0.486514E+09 | 0.271186E+09 |
March | 0.476557E+09 | 0.301751E+09 | 0.174806E+09 | 0.486535E+09 | 0.245244E+09 |
April | 0.418619E+09 | 0.227752E+09 | 0.190867E+09 | 0.463008E+09 | 0.157469E+09 |
May | 0.363849E+09 | 0.125174E+09 | 0.238675E+09 | 0.429887E+09 | 96800442.28 |
June | 0.315960E+09 | 84987668.72 | 0.230973E+09 | 0.391027E+09 | 67464289.70 |
July | 0.357036E+09 | 0.113969E+09 | 0.243067E+09 | 0.457742E+09 | 66198311.47 |
August | 0.381049E+09 | 0.160031E+09 | 0.221018E+09 | 0.475730E+09 | 77603798.88 |
September | 0.394486E+09 | 0.210389E+09 | 0.184096E+09 | 0.462955E+09 | 0.113193E+09 |
October | 0.347452E+09 | 0.204321E+09 | 0.143131E+09 | 0.369283E+09 | 0.163888E+09 |
November | 0.298910E+09 | 0.187343E+09 | 0.111567E+09 | 0.284799E+09 | 0.224876E+09 |
December | 0.328529E+09 | 0.215085E+09 | 0.113444E+09 | 0.273990E+09 | 0.348530E+09 |
Annual Sum or Average | 0.459536E+10 | 0.245544E+10 | 0.213993E+10 | 0.496289E+10 | 0.219315E+10 |
Minimum of Months | 0.298910E+09 | 84987668.72 | 0.111567E+09 | 0.273990E+09 | 66198311.47 |
Maximum of Months | 0.487361E+09 | 0.328949E+09 | 0.243067E+09 | 0.486535E+09 | 0.360702E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.318013E+09 | 0.303846E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.406001E+09 | 0.228011E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.406406E+09 | 0.205877E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.386956E+09 | 0.132050E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.359537E+09 | 81061044.41 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.327259E+09 | 56324350.73 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.383153E+09 | 55228821.28 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.397948E+09 | 64881907.42 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.386880E+09 | 95210735.33 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.308476E+09 | 0.137703E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.237757E+09 | 0.188695E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.228286E+09 | 0.293652E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.414667E+10 | 0.184254E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.228286E+09 | 55228821.28 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.406406E+09 | 0.303846E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.318013E+09 | 0.303846E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.406001E+09 | 0.228011E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.406406E+09 | 0.205877E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.386956E+09 | 0.132050E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.359537E+09 | 81061044.41 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.327259E+09 | 56324350.73 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.383153E+09 | 55228821.28 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.397948E+09 | 64881907.42 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.386880E+09 | 95210735.33 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.308476E+09 | 0.137703E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.237757E+09 | 0.188695E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.228286E+09 | 0.293652E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.414667E+10 | 0.184254E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.228286E+09 | 55228821.28 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.406406E+09 | 0.303846E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_DOOR
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.425553E+09 | 0.295683E+09 | 0.129870E+09 | 0.381782E+09 | 0.359214E+09 |
February | 0.487361E+09 | 0.328949E+09 | 0.158412E+09 | 0.486966E+09 | 0.269720E+09 |
March | 0.476557E+09 | 0.301751E+09 | 0.174806E+09 | 0.487009E+09 | 0.243667E+09 |
April | 0.418619E+09 | 0.227752E+09 | 0.190867E+09 | 0.463413E+09 | 0.156477E+09 |
May | 0.363849E+09 | 0.125174E+09 | 0.238675E+09 | 0.430215E+09 | 96246325.96 |
June | 0.315960E+09 | 84987668.72 | 0.230973E+09 | 0.391345E+09 | 66974234.10 |
July | 0.357036E+09 | 0.113969E+09 | 0.243067E+09 | 0.458013E+09 | 65714169.76 |
August | 0.381049E+09 | 0.160031E+09 | 0.221018E+09 | 0.475962E+09 | 77086573.93 |
September | 0.394486E+09 | 0.210389E+09 | 0.184096E+09 | 0.463043E+09 | 0.112942E+09 |
October | 0.347452E+09 | 0.204321E+09 | 0.143131E+09 | 0.369500E+09 | 0.163246E+09 |
November | 0.298910E+09 | 0.187343E+09 | 0.111567E+09 | 0.285242E+09 | 0.223260E+09 |
December | 0.328529E+09 | 0.215085E+09 | 0.113444E+09 | 0.274311E+09 | 0.346980E+09 |
Annual Sum or Average | 0.459536E+10 | 0.245544E+10 | 0.213993E+10 | 0.496680E+10 | 0.218153E+10 |
Minimum of Months | 0.298910E+09 | 84987668.72 | 0.111567E+09 | 0.274311E+09 | 65714169.76 |
Maximum of Months | 0.487361E+09 | 0.328949E+09 | 0.243067E+09 | 0.487009E+09 | 0.359214E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.320257E+09 | 0.298944E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.408470E+09 | 0.223957E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.408578E+09 | 0.201942E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.387379E+09 | 0.130941E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.358468E+09 | 80859162.64 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.327090E+09 | 55568882.35 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.383077E+09 | 54178382.51 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.397950E+09 | 63882915.21 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.385567E+09 | 96059402.61 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.308141E+09 | 0.138019E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.239369E+09 | 0.184972E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.230224E+09 | 0.288506E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.415457E+10 | 0.181783E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.230224E+09 | 54178382.51 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.408578E+09 | 0.298944E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.320257E+09 | 0.298944E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.408470E+09 | 0.223957E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.408578E+09 | 0.201942E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.387379E+09 | 0.130941E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.358468E+09 | 80859162.64 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.327090E+09 | 55568882.35 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.383077E+09 | 54178382.51 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.397950E+09 | 63882915.21 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.385567E+09 | 96059402.61 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.308141E+09 | 0.138019E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.239369E+09 | 0.184972E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.230224E+09 | 0.288506E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.415457E+10 | 0.181783E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.230224E+09 | 54178382.51 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.408578E+09 | 0.298944E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.320257E+09 | 0.298944E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.408470E+09 | 0.223957E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.408578E+09 | 0.201942E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.387379E+09 | 0.130941E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.358468E+09 | 80859162.64 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.327090E+09 | 55568882.35 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.383077E+09 | 54178382.51 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.397950E+09 | 63882915.21 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.385567E+09 | 96059402.61 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.308141E+09 | 0.138019E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.239369E+09 | 0.184972E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.230224E+09 | 0.288506E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.415457E+10 | 0.181783E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.230224E+09 | 54178382.51 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.408578E+09 | 0.298944E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.320257E+09 | 0.298944E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.408470E+09 | 0.223957E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.408578E+09 | 0.201942E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.387379E+09 | 0.130941E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.358468E+09 | 80859162.64 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.327090E+09 | 55568882.35 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.383077E+09 | 54178382.51 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.397950E+09 | 63882915.21 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.385567E+09 | 96059402.61 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.308141E+09 | 0.138019E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.239369E+09 | 0.184972E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.230224E+09 | 0.288506E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.415457E+10 | 0.181783E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.230224E+09 | 54178382.51 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.408578E+09 | 0.298944E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_DOOR_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.425553E+09 | 0.295683E+09 | 0.129870E+09 | 0.384389E+09 | 0.353560E+09 |
February | 0.487361E+09 | 0.328949E+09 | 0.158412E+09 | 0.489810E+09 | 0.265023E+09 |
March | 0.476557E+09 | 0.301751E+09 | 0.174806E+09 | 0.489526E+09 | 0.239085E+09 |
April | 0.418619E+09 | 0.227752E+09 | 0.190867E+09 | 0.463878E+09 | 0.155201E+09 |
May | 0.363849E+09 | 0.125174E+09 | 0.238675E+09 | 0.428929E+09 | 96016254.76 |
June | 0.315960E+09 | 84987668.72 | 0.230973E+09 | 0.391121E+09 | 66081923.68 |
July | 0.357036E+09 | 0.113969E+09 | 0.243067E+09 | 0.457898E+09 | 64472812.41 |
August | 0.381049E+09 | 0.160031E+09 | 0.221018E+09 | 0.475926E+09 | 75914409.99 |
September | 0.394486E+09 | 0.210389E+09 | 0.184096E+09 | 0.461450E+09 | 0.113959E+09 |
October | 0.347452E+09 | 0.204321E+09 | 0.143131E+09 | 0.369074E+09 | 0.163652E+09 |
November | 0.298910E+09 | 0.187343E+09 | 0.111567E+09 | 0.287115E+09 | 0.218933E+09 |
December | 0.328529E+09 | 0.215085E+09 | 0.113444E+09 | 0.276560E+09 | 0.341043E+09 |
Annual Sum or Average | 0.459536E+10 | 0.245544E+10 | 0.213993E+10 | 0.497568E+10 | 0.215294E+10 |
Minimum of Months | 0.298910E+09 | 84987668.72 | 0.111567E+09 | 0.276560E+09 | 64472812.41 |
Maximum of Months | 0.487361E+09 | 0.328949E+09 | 0.243067E+09 | 0.489810E+09 | 0.353560E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_DOOR_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.425553E+09 | 0.295683E+09 | 0.129870E+09 | 0.384389E+09 | 0.353560E+09 |
February | 0.487361E+09 | 0.328949E+09 | 0.158412E+09 | 0.489810E+09 | 0.265023E+09 |
March | 0.476557E+09 | 0.301751E+09 | 0.174806E+09 | 0.489526E+09 | 0.239085E+09 |
April | 0.418619E+09 | 0.227752E+09 | 0.190867E+09 | 0.463878E+09 | 0.155201E+09 |
May | 0.363849E+09 | 0.125174E+09 | 0.238675E+09 | 0.428929E+09 | 96016254.76 |
June | 0.315960E+09 | 84987668.72 | 0.230973E+09 | 0.391121E+09 | 66081923.68 |
July | 0.357036E+09 | 0.113969E+09 | 0.243067E+09 | 0.457898E+09 | 64472812.41 |
August | 0.381049E+09 | 0.160031E+09 | 0.221018E+09 | 0.475926E+09 | 75914409.99 |
September | 0.394486E+09 | 0.210389E+09 | 0.184096E+09 | 0.461450E+09 | 0.113959E+09 |
October | 0.347452E+09 | 0.204321E+09 | 0.143131E+09 | 0.369074E+09 | 0.163652E+09 |
November | 0.298910E+09 | 0.187343E+09 | 0.111567E+09 | 0.287115E+09 | 0.218933E+09 |
December | 0.328529E+09 | 0.215085E+09 | 0.113444E+09 | 0.276560E+09 | 0.341043E+09 |
Annual Sum or Average | 0.459536E+10 | 0.245544E+10 | 0.213993E+10 | 0.497568E+10 | 0.215294E+10 |
Minimum of Months | 0.298910E+09 | 84987668.72 | 0.111567E+09 | 0.276560E+09 | 64472812.41 |
Maximum of Months | 0.487361E+09 | 0.328949E+09 | 0.243067E+09 | 0.489810E+09 | 0.353560E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.319117E+09 | 0.300835E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.407314E+09 | 0.225248E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.407649E+09 | 0.202877E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.388054E+09 | 0.129511E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.360269E+09 | 79025237.58 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.327775E+09 | 54629405.49 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.383160E+09 | 53655553.29 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.397957E+09 | 63235262.55 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.387071E+09 | 93532027.15 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.309162E+09 | 0.135554E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.238762E+09 | 0.185748E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.229271E+09 | 0.290550E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.415556E+10 | 0.181440E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.229271E+09 | 53655553.29 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.407649E+09 | 0.300835E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.319117E+09 | 0.300835E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.407314E+09 | 0.225248E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.407649E+09 | 0.202877E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.388054E+09 | 0.129511E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.360269E+09 | 79025237.58 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.327775E+09 | 54629405.49 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.383160E+09 | 53655553.29 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.397957E+09 | 63235262.55 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.387071E+09 | 93532027.15 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.309162E+09 | 0.135554E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.238762E+09 | 0.185748E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.229271E+09 | 0.290550E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.415556E+10 | 0.181440E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.229271E+09 | 53655553.29 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.407649E+09 | 0.300835E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_DOOR
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.425553E+09 | 0.295683E+09 | 0.129870E+09 | 0.383119E+09 | 0.355656E+09 |
February | 0.487361E+09 | 0.328949E+09 | 0.158412E+09 | 0.488542E+09 | 0.266451E+09 |
March | 0.476557E+09 | 0.301751E+09 | 0.174806E+09 | 0.488509E+09 | 0.240111E+09 |
April | 0.418619E+09 | 0.227752E+09 | 0.190867E+09 | 0.464739E+09 | 0.153469E+09 |
May | 0.363849E+09 | 0.125174E+09 | 0.238675E+09 | 0.431108E+09 | 93837777.72 |
June | 0.315960E+09 | 84987668.72 | 0.230973E+09 | 0.391977E+09 | 64965945.28 |
July | 0.357036E+09 | 0.113969E+09 | 0.243067E+09 | 0.458045E+09 | 63851993.74 |
August | 0.381049E+09 | 0.160031E+09 | 0.221018E+09 | 0.475995E+09 | 75138352.97 |
September | 0.394486E+09 | 0.210389E+09 | 0.184096E+09 | 0.463288E+09 | 0.110950E+09 |
October | 0.347452E+09 | 0.204321E+09 | 0.143131E+09 | 0.370336E+09 | 0.160699E+09 |
November | 0.298910E+09 | 0.187343E+09 | 0.111567E+09 | 0.286454E+09 | 0.219769E+09 |
December | 0.328529E+09 | 0.215085E+09 | 0.113444E+09 | 0.275501E+09 | 0.343314E+09 |
Annual Sum or Average | 0.459536E+10 | 0.245544E+10 | 0.213993E+10 | 0.497761E+10 | 0.214821E+10 |
Minimum of Months | 0.298910E+09 | 84987668.72 | 0.111567E+09 | 0.275501E+09 | 63851993.74 |
Maximum of Months | 0.487361E+09 | 0.328949E+09 | 0.243067E+09 | 0.488542E+09 | 0.355656E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.319176E+09 | 0.300583E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.407421E+09 | 0.224904E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.407811E+09 | 0.202357E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.388662E+09 | 0.128309E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.361248E+09 | 77886214.42 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.328455E+09 | 53949549.53 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.383429E+09 | 53364958.70 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.398241E+09 | 62829331.45 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.387791E+09 | 92297686.19 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.309750E+09 | 0.134183E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.238945E+09 | 0.185123E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.229331E+09 | 0.290261E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.416026E+10 | 0.180605E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.229331E+09 | 53364958.70 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.407811E+09 | 0.300583E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.319176E+09 | 0.300583E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.407421E+09 | 0.224904E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.407811E+09 | 0.202357E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.388662E+09 | 0.128309E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.361248E+09 | 77886214.42 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.328455E+09 | 53949549.53 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.383429E+09 | 53364958.70 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.398241E+09 | 62829331.45 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.387791E+09 | 92297686.19 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.309750E+09 | 0.134183E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.238945E+09 | 0.185123E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.229331E+09 | 0.290261E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.416026E+10 | 0.180605E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.229331E+09 | 53364958.70 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.407811E+09 | 0.300583E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_DOOR
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.425553E+09 | 0.295683E+09 | 0.129870E+09 | 0.383191E+09 | 0.355357E+09 |
February | 0.487361E+09 | 0.328949E+09 | 0.158412E+09 | 0.488670E+09 | 0.266042E+09 |
March | 0.476557E+09 | 0.301751E+09 | 0.174806E+09 | 0.488706E+09 | 0.239491E+09 |
April | 0.418619E+09 | 0.227752E+09 | 0.190867E+09 | 0.465471E+09 | 0.152045E+09 |
May | 0.363849E+09 | 0.125174E+09 | 0.238675E+09 | 0.432278E+09 | 92490472.99 |
June | 0.315960E+09 | 84987668.72 | 0.230973E+09 | 0.392789E+09 | 64160326.50 |
July | 0.357036E+09 | 0.113969E+09 | 0.243067E+09 | 0.458367E+09 | 63507090.94 |
August | 0.381049E+09 | 0.160031E+09 | 0.221018E+09 | 0.476335E+09 | 74657578.10 |
September | 0.394486E+09 | 0.210389E+09 | 0.184096E+09 | 0.464149E+09 | 0.109489E+09 |
October | 0.347452E+09 | 0.204321E+09 | 0.143131E+09 | 0.371043E+09 | 0.159072E+09 |
November | 0.298910E+09 | 0.187343E+09 | 0.111567E+09 | 0.286675E+09 | 0.219027E+09 |
December | 0.328529E+09 | 0.215085E+09 | 0.113444E+09 | 0.275574E+09 | 0.342970E+09 |
Annual Sum or Average | 0.459536E+10 | 0.245544E+10 | 0.213993E+10 | 0.498325E+10 | 0.213831E+10 |
Minimum of Months | 0.298910E+09 | 84987668.72 | 0.111567E+09 | 0.275574E+09 | 63507090.94 |
Maximum of Months | 0.487361E+09 | 0.328949E+09 | 0.243067E+09 | 0.488706E+09 | 0.355357E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.319547E+09 | 0.298734E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.407927E+09 | 0.222889E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.408498E+09 | 0.199741E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.389881E+09 | 0.125414E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.362898E+09 | 75785079.45 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.329693E+09 | 52592755.79 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.383997E+09 | 52650659.19 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.398818E+09 | 61901422.02 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.388791E+09 | 90497622.93 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.310662E+09 | 0.131749E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.239579E+09 | 0.182583E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.229684E+09 | 0.288209E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.416997E+10 | 0.178275E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.229684E+09 | 52592755.79 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.408498E+09 | 0.298734E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.319547E+09 | 0.298734E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.407927E+09 | 0.222889E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.408498E+09 | 0.199741E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.389881E+09 | 0.125414E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.362898E+09 | 75785079.45 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.329693E+09 | 52592755.79 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.383997E+09 | 52650659.19 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.398818E+09 | 61901422.02 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.388791E+09 | 90497622.93 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.310662E+09 | 0.131749E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.239579E+09 | 0.182583E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.229684E+09 | 0.288209E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.416997E+10 | 0.178275E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.229684E+09 | 52592755.79 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.408498E+09 | 0.298734E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_DOOR
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.425553E+09 | 0.295683E+09 | 0.129870E+09 | 0.383645E+09 | 0.353155E+09 |
February | 0.487361E+09 | 0.328949E+09 | 0.158412E+09 | 0.489286E+09 | 0.263649E+09 |
March | 0.476557E+09 | 0.301751E+09 | 0.174806E+09 | 0.489537E+09 | 0.236382E+09 |
April | 0.418619E+09 | 0.227752E+09 | 0.190867E+09 | 0.466939E+09 | 0.148617E+09 |
May | 0.363849E+09 | 0.125174E+09 | 0.238675E+09 | 0.434248E+09 | 90007176.03 |
June | 0.315960E+09 | 84987668.72 | 0.230973E+09 | 0.394265E+09 | 62554391.36 |
July | 0.357036E+09 | 0.113969E+09 | 0.243067E+09 | 0.459047E+09 | 62664199.54 |
August | 0.381049E+09 | 0.160031E+09 | 0.221018E+09 | 0.477025E+09 | 73563020.21 |
September | 0.394486E+09 | 0.210389E+09 | 0.184096E+09 | 0.465344E+09 | 0.107361E+09 |
October | 0.347452E+09 | 0.204321E+09 | 0.143131E+09 | 0.372143E+09 | 0.156192E+09 |
November | 0.298910E+09 | 0.187343E+09 | 0.111567E+09 | 0.287443E+09 | 0.216015E+09 |
December | 0.328529E+09 | 0.215085E+09 | 0.113444E+09 | 0.276004E+09 | 0.340529E+09 |
Annual Sum or Average | 0.459536E+10 | 0.245544E+10 | 0.213993E+10 | 0.499493E+10 | 0.211069E+10 |
Minimum of Months | 0.298910E+09 | 84987668.72 | 0.111567E+09 | 0.276004E+09 | 62554391.36 |
Maximum of Months | 0.487361E+09 | 0.328949E+09 | 0.243067E+09 | 0.489537E+09 | 0.353155E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_WINDOW_1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.321987E+09 | 0.289024E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.410476E+09 | 0.213719E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.411415E+09 | 0.188232E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.393323E+09 | 0.114770E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.366878E+09 | 69106218.56 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.332338E+09 | 48279338.19 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.385187E+09 | 49893406.26 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.400199E+09 | 58536987.70 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.391028E+09 | 84993587.70 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.313171E+09 | 0.123564E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.241908E+09 | 0.172383E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.231779E+09 | 0.278078E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.419969E+10 | 0.169058E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.231779E+09 | 48279338.19 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.411415E+09 | 0.289024E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_WINDOW_2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.355937E+09 | 0.247313E+09 | 0.108624E+09 | 0.321987E+09 | 0.289024E+09 |
February | 0.407634E+09 | 0.275137E+09 | 0.132498E+09 | 0.410476E+09 | 0.213719E+09 |
March | 0.398597E+09 | 0.252388E+09 | 0.146210E+09 | 0.411415E+09 | 0.188232E+09 |
April | 0.350138E+09 | 0.190495E+09 | 0.159643E+09 | 0.393323E+09 | 0.114770E+09 |
May | 0.304327E+09 | 0.104697E+09 | 0.199630E+09 | 0.366878E+09 | 69106218.56 |
June | 0.264273E+09 | 71084600.99 | 0.193188E+09 | 0.332338E+09 | 48279338.19 |
July | 0.298629E+09 | 95324627.14 | 0.203304E+09 | 0.385187E+09 | 49893406.26 |
August | 0.318714E+09 | 0.133851E+09 | 0.184862E+09 | 0.400199E+09 | 58536987.70 |
September | 0.329952E+09 | 0.175972E+09 | 0.153980E+09 | 0.391028E+09 | 84993587.70 |
October | 0.290613E+09 | 0.170896E+09 | 0.119717E+09 | 0.313171E+09 | 0.123564E+09 |
November | 0.250011E+09 | 0.156696E+09 | 93315453.69 | 0.241908E+09 | 0.172383E+09 |
December | 0.274785E+09 | 0.179900E+09 | 94885566.97 | 0.231779E+09 | 0.278078E+09 |
Annual Sum or Average | 0.384361E+10 | 0.205375E+10 | 0.178986E+10 | 0.419969E+10 | 0.169058E+10 |
Minimum of Months | 0.250011E+09 | 71084600.99 | 93315453.69 | 0.231779E+09 | 48279338.19 |
Maximum of Months | 0.407634E+09 | 0.275137E+09 | 0.203304E+09 | 0.411415E+09 | 0.289024E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_DOOR
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.425553E+09 | 0.295683E+09 | 0.129870E+09 | 0.386617E+09 | 0.341512E+09 |
February | 0.487361E+09 | 0.328949E+09 | 0.158412E+09 | 0.492382E+09 | 0.252700E+09 |
March | 0.476557E+09 | 0.301751E+09 | 0.174806E+09 | 0.493084E+09 | 0.222682E+09 |
April | 0.418619E+09 | 0.227752E+09 | 0.190867E+09 | 0.471102E+09 | 0.136025E+09 |
May | 0.363849E+09 | 0.125174E+09 | 0.238675E+09 | 0.439007E+09 | 82117667.53 |
June | 0.315960E+09 | 84987668.72 | 0.230973E+09 | 0.397417E+09 | 57451160.21 |
July | 0.357036E+09 | 0.113969E+09 | 0.243067E+09 | 0.460459E+09 | 59401635.41 |
August | 0.381049E+09 | 0.160031E+09 | 0.221018E+09 | 0.478671E+09 | 69591251.04 |
September | 0.394486E+09 | 0.210389E+09 | 0.184096E+09 | 0.468020E+09 | 0.100859E+09 |
October | 0.347452E+09 | 0.204321E+09 | 0.143131E+09 | 0.375176E+09 | 0.146504E+09 |
November | 0.298910E+09 | 0.187343E+09 | 0.111567E+09 | 0.290278E+09 | 0.203930E+09 |
December | 0.328529E+09 | 0.215085E+09 | 0.113444E+09 | 0.278563E+09 | 0.328413E+09 |
Annual Sum or Average | 0.459536E+10 | 0.245544E+10 | 0.213993E+10 | 0.503078E+10 | 0.200119E+10 |
Minimum of Months | 0.298910E+09 | 84987668.72 | 0.111567E+09 | 0.278563E+09 | 57451160.21 |
Maximum of Months | 0.487361E+09 | 0.328949E+09 | 0.243067E+09 | 0.493084E+09 | 0.341512E+09 |
Report: WindowZoneSummaryMonthly
For: LGSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 767.37 | 723.43 | 851.08 | 591.35 | 259.73 | 0.00 | 0.00 |
February | 1083.14 | 598.66 | 1079.12 | 728.36 | 350.76 | 0.00 | 0.00 |
March | 979.06 | 485.80 | 953.08 | 603.48 | 349.60 | 0.00 | 0.00 |
April | 958.62 | 326.31 | 865.12 | 470.67 | 394.45 | 0.00 | 0.00 |
May | 858.60 | 192.93 | 727.67 | 250.34 | 477.33 | 0.00 | 0.00 |
June | 811.03 | 133.36 | 652.96 | 175.64 | 477.33 | 0.00 | 0.00 |
July | 920.47 | 122.87 | 714.05 | 227.93 | 486.12 | 0.00 | 0.00 |
August | 954.31 | 146.54 | 762.07 | 320.05 | 442.02 | 0.00 | 0.00 |
September | 953.79 | 234.74 | 815.25 | 434.79 | 380.45 | 0.00 | 0.00 |
October | 735.49 | 336.82 | 694.88 | 408.63 | 286.25 | 0.00 | 0.00 |
November | 591.68 | 463.71 | 617.73 | 387.16 | 230.56 | 0.00 | 0.00 |
December | 551.82 | 697.74 | 657.04 | 430.16 | 226.88 | 0.00 | 0.00 |
Annual Sum or Average | 845.38 | 370.95 | 780.56 | 417.07 | 363.48 | 0.00 | 0.00 |
Minimum of Months | 551.82 | 122.87 | 617.73 | 175.64 | 226.88 | 0.00 | 0.00 |
Maximum of Months | 1083.14 | 723.43 | 1079.12 | 728.36 | 486.12 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 380.05 | 372.24 | 425.54 | 295.67 | 129.87 | 0.00 | 0.00 |
February | 537.06 | 309.85 | 539.56 | 364.18 | 175.38 | 0.00 | 0.00 |
March | 485.47 | 253.05 | 476.54 | 301.74 | 174.80 | 0.00 | 0.00 |
April | 476.37 | 170.12 | 432.56 | 235.34 | 197.22 | 0.00 | 0.00 |
May | 428.05 | 98.55 | 363.84 | 125.17 | 238.67 | 0.00 | 0.00 |
June | 403.95 | 68.19 | 326.48 | 87.82 | 238.66 | 0.00 | 0.00 |
July | 459.14 | 62.37 | 357.02 | 113.97 | 243.06 | 0.00 | 0.00 |
August | 476.04 | 74.48 | 381.04 | 160.03 | 221.01 | 0.00 | 0.00 |
September | 476.61 | 118.64 | 407.62 | 217.40 | 190.23 | 0.00 | 0.00 |
October | 366.90 | 171.82 | 347.44 | 204.31 | 143.13 | 0.00 | 0.00 |
November | 292.79 | 241.18 | 308.86 | 193.58 | 115.28 | 0.00 | 0.00 |
December | 272.82 | 359.70 | 328.52 | 215.08 | 113.44 | 0.00 | 0.00 |
Annual Sum or Average | 420.42 | 191.17 | 390.28 | 208.54 | 181.74 | 0.00 | 0.00 |
Minimum of Months | 272.82 | 62.37 | 308.86 | 87.82 | 113.44 | 0.00 | 0.00 |
Maximum of Months | 537.06 | 372.24 | 539.56 | 364.18 | 243.06 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 379.34 | 364.83 | 424.67 | 295.07 | 129.60 | 0.00 | 0.00 |
February | 536.03 | 303.86 | 538.45 | 363.44 | 175.02 | 0.00 | 0.00 |
March | 484.45 | 248.29 | 475.56 | 301.12 | 174.44 | 0.00 | 0.00 |
April | 476.30 | 165.36 | 431.67 | 234.85 | 196.82 | 0.00 | 0.00 |
May | 428.14 | 98.12 | 363.09 | 124.91 | 238.18 | 0.00 | 0.00 |
June | 402.87 | 70.22 | 325.81 | 87.64 | 238.17 | 0.00 | 0.00 |
July | 456.85 | 66.20 | 356.29 | 113.73 | 242.56 | 0.00 | 0.00 |
August | 474.57 | 77.85 | 380.26 | 159.70 | 220.56 | 0.00 | 0.00 |
September | 476.63 | 118.33 | 406.79 | 216.95 | 189.84 | 0.00 | 0.00 |
October | 367.46 | 166.55 | 346.73 | 203.90 | 142.83 | 0.00 | 0.00 |
November | 292.63 | 235.73 | 308.23 | 193.18 | 115.05 | 0.00 | 0.00 |
December | 272.30 | 352.69 | 327.84 | 214.64 | 113.21 | 0.00 | 0.00 |
Annual Sum or Average | 419.78 | 188.51 | 389.48 | 208.11 | 181.37 | 0.00 | 0.00 |
Minimum of Months | 272.30 | 66.20 | 308.23 | 87.64 | 113.21 | 0.00 | 0.00 |
Maximum of Months | 536.03 | 364.83 | 538.45 | 363.44 | 242.56 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 379.65 | 362.49 | 424.67 | 295.07 | 129.60 | 0.00 | 0.00 |
February | 536.45 | 301.62 | 538.45 | 363.44 | 175.02 | 0.00 | 0.00 |
March | 484.83 | 246.29 | 475.56 | 301.12 | 174.44 | 0.00 | 0.00 |
April | 476.95 | 163.29 | 431.67 | 234.85 | 196.82 | 0.00 | 0.00 |
May | 428.77 | 97.02 | 363.09 | 124.91 | 238.18 | 0.00 | 0.00 |
June | 403.17 | 69.81 | 325.81 | 87.64 | 238.17 | 0.00 | 0.00 |
July | 456.84 | 66.26 | 356.29 | 113.73 | 242.56 | 0.00 | 0.00 |
August | 474.63 | 77.75 | 380.26 | 159.70 | 220.56 | 0.00 | 0.00 |
September | 477.07 | 117.30 | 406.79 | 216.95 | 189.84 | 0.00 | 0.00 |
October | 368.08 | 164.42 | 346.73 | 203.90 | 142.83 | 0.00 | 0.00 |
November | 293.05 | 233.41 | 308.23 | 193.18 | 115.05 | 0.00 | 0.00 |
December | 272.56 | 350.37 | 327.84 | 214.64 | 113.21 | 0.00 | 0.00 |
Annual Sum or Average | 420.15 | 187.02 | 389.48 | 208.11 | 181.37 | 0.00 | 0.00 |
Minimum of Months | 272.56 | 66.26 | 308.23 | 87.64 | 113.21 | 0.00 | 0.00 |
Maximum of Months | 536.45 | 362.49 | 538.45 | 363.44 | 242.56 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 380.01 | 361.00 | 424.67 | 295.07 | 129.60 | 0.00 | 0.00 |
February | 536.94 | 299.99 | 538.45 | 363.44 | 175.02 | 0.00 | 0.00 |
March | 485.30 | 244.71 | 475.56 | 301.12 | 174.44 | 0.00 | 0.00 |
April | 477.36 | 162.26 | 431.67 | 234.85 | 196.82 | 0.00 | 0.00 |
May | 429.09 | 96.46 | 363.09 | 124.91 | 238.18 | 0.00 | 0.00 |
June | 403.50 | 69.30 | 325.81 | 87.64 | 238.17 | 0.00 | 0.00 |
July | 457.11 | 65.78 | 356.29 | 113.73 | 242.56 | 0.00 | 0.00 |
August | 474.86 | 77.23 | 380.26 | 159.70 | 220.56 | 0.00 | 0.00 |
September | 477.16 | 117.04 | 406.79 | 216.95 | 189.84 | 0.00 | 0.00 |
October | 368.30 | 163.77 | 346.73 | 203.90 | 142.83 | 0.00 | 0.00 |
November | 293.50 | 231.73 | 308.23 | 193.18 | 115.05 | 0.00 | 0.00 |
December | 272.88 | 348.82 | 327.84 | 214.64 | 113.21 | 0.00 | 0.00 |
Annual Sum or Average | 420.48 | 186.03 | 389.48 | 208.11 | 181.37 | 0.00 | 0.00 |
Minimum of Months | 272.88 | 65.78 | 308.23 | 87.64 | 113.21 | 0.00 | 0.00 |
Maximum of Months | 536.94 | 361.00 | 538.45 | 363.44 | 242.56 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: LGSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 765.31 | 710.46 | 849.33 | 590.14 | 259.20 | 0.00 | 0.00 |
February | 1080.31 | 589.40 | 1076.91 | 726.87 | 350.04 | 0.00 | 0.00 |
March | 975.72 | 480.11 | 951.13 | 602.25 | 348.88 | 0.00 | 0.00 |
April | 955.74 | 321.82 | 863.35 | 469.71 | 393.64 | 0.00 | 0.00 |
May | 855.63 | 192.45 | 726.18 | 249.83 | 476.36 | 0.00 | 0.00 |
June | 806.56 | 136.74 | 651.62 | 175.28 | 476.35 | 0.00 | 0.00 |
July | 914.02 | 129.05 | 712.58 | 227.46 | 485.12 | 0.00 | 0.00 |
August | 949.69 | 152.09 | 760.51 | 319.39 | 441.12 | 0.00 | 0.00 |
September | 951.07 | 236.17 | 813.57 | 433.90 | 379.67 | 0.00 | 0.00 |
October | 735.78 | 328.32 | 693.46 | 407.79 | 285.67 | 0.00 | 0.00 |
November | 590.93 | 454.38 | 616.46 | 386.37 | 230.09 | 0.00 | 0.00 |
December | 550.33 | 685.52 | 655.69 | 429.27 | 226.41 | 0.00 | 0.00 |
Annual Sum or Average | 842.52 | 367.11 | 778.96 | 416.22 | 362.74 | 0.00 | 0.00 |
Minimum of Months | 550.33 | 129.05 | 616.46 | 175.28 | 226.41 | 0.00 | 0.00 |
Maximum of Months | 1080.31 | 710.46 | 1076.91 | 726.87 | 485.12 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 381.33 | 357.42 | 424.67 | 295.07 | 129.60 | 0.00 | 0.00 |
February | 538.68 | 296.36 | 538.45 | 363.44 | 175.02 | 0.00 | 0.00 |
March | 486.79 | 241.14 | 475.56 | 301.12 | 174.44 | 0.00 | 0.00 |
April | 478.72 | 159.14 | 431.67 | 234.85 | 196.82 | 0.00 | 0.00 |
May | 429.98 | 94.04 | 363.09 | 124.91 | 238.18 | 0.00 | 0.00 |
June | 404.14 | 67.22 | 325.81 | 87.64 | 238.17 | 0.00 | 0.00 |
July | 457.13 | 63.90 | 356.29 | 113.73 | 242.56 | 0.00 | 0.00 |
August | 474.88 | 75.27 | 380.26 | 159.70 | 220.56 | 0.00 | 0.00 |
September | 477.40 | 114.97 | 406.79 | 216.95 | 189.84 | 0.00 | 0.00 |
October | 369.12 | 161.22 | 346.73 | 203.90 | 142.83 | 0.00 | 0.00 |
November | 294.74 | 228.11 | 308.23 | 193.18 | 115.05 | 0.00 | 0.00 |
December | 274.06 | 345.14 | 327.84 | 214.64 | 113.21 | 0.00 | 0.00 |
Annual Sum or Average | 421.38 | 183.19 | 389.48 | 208.11 | 181.37 | 0.00 | 0.00 |
Minimum of Months | 274.06 | 63.90 | 308.23 | 87.64 | 113.21 | 0.00 | 0.00 |
Maximum of Months | 538.68 | 357.42 | 538.45 | 363.44 | 242.56 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 381.40 | 357.12 | 424.67 | 295.07 | 129.60 | 0.00 | 0.00 |
February | 538.82 | 295.90 | 538.45 | 363.44 | 175.02 | 0.00 | 0.00 |
March | 486.98 | 240.52 | 475.56 | 301.12 | 174.44 | 0.00 | 0.00 |
April | 479.47 | 157.66 | 431.67 | 234.85 | 196.82 | 0.00 | 0.00 |
May | 431.14 | 92.69 | 363.09 | 124.91 | 238.18 | 0.00 | 0.00 |
June | 404.98 | 66.38 | 325.81 | 87.64 | 238.17 | 0.00 | 0.00 |
July | 457.45 | 63.56 | 356.29 | 113.73 | 242.56 | 0.00 | 0.00 |
August | 475.22 | 74.79 | 380.26 | 159.70 | 220.56 | 0.00 | 0.00 |
September | 478.29 | 113.46 | 406.79 | 216.95 | 189.84 | 0.00 | 0.00 |
October | 369.83 | 159.59 | 346.73 | 203.90 | 142.83 | 0.00 | 0.00 |
November | 294.97 | 227.34 | 308.23 | 193.18 | 115.05 | 0.00 | 0.00 |
December | 274.13 | 344.79 | 327.84 | 214.64 | 113.21 | 0.00 | 0.00 |
Annual Sum or Average | 421.86 | 182.34 | 389.48 | 208.11 | 181.37 | 0.00 | 0.00 |
Minimum of Months | 274.13 | 63.56 | 308.23 | 87.64 | 113.21 | 0.00 | 0.00 |
Maximum of Months | 538.82 | 357.12 | 538.45 | 363.44 | 242.56 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 381.84 | 354.92 | 424.67 | 295.07 | 129.60 | 0.00 | 0.00 |
February | 539.49 | 293.25 | 538.45 | 363.44 | 175.02 | 0.00 | 0.00 |
March | 487.80 | 237.40 | 475.56 | 301.12 | 174.44 | 0.00 | 0.00 |
April | 480.98 | 154.11 | 431.67 | 234.85 | 196.82 | 0.00 | 0.00 |
May | 433.11 | 90.19 | 363.09 | 124.91 | 238.18 | 0.00 | 0.00 |
June | 406.50 | 64.71 | 325.81 | 87.64 | 238.17 | 0.00 | 0.00 |
July | 458.12 | 62.71 | 356.29 | 113.73 | 242.56 | 0.00 | 0.00 |
August | 475.90 | 73.69 | 380.26 | 159.70 | 220.56 | 0.00 | 0.00 |
September | 479.52 | 111.25 | 406.79 | 216.95 | 189.84 | 0.00 | 0.00 |
October | 370.92 | 156.69 | 346.73 | 203.90 | 142.83 | 0.00 | 0.00 |
November | 295.76 | 224.22 | 308.23 | 193.18 | 115.05 | 0.00 | 0.00 |
December | 274.56 | 342.35 | 327.84 | 214.64 | 113.21 | 0.00 | 0.00 |
Annual Sum or Average | 422.85 | 179.99 | 389.48 | 208.11 | 181.37 | 0.00 | 0.00 |
Minimum of Months | 274.56 | 62.71 | 308.23 | 87.64 | 113.21 | 0.00 | 0.00 |
Maximum of Months | 539.49 | 354.92 | 538.45 | 363.44 | 242.56 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE8
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 384.78 | 343.32 | 424.67 | 295.07 | 129.60 | 0.00 | 0.00 |
February | 542.88 | 281.14 | 538.45 | 363.44 | 175.02 | 0.00 | 0.00 |
March | 491.31 | 223.70 | 475.56 | 301.12 | 174.44 | 0.00 | 0.00 |
April | 485.24 | 141.04 | 431.67 | 234.85 | 196.82 | 0.00 | 0.00 |
May | 437.86 | 82.26 | 363.09 | 124.91 | 238.18 | 0.00 | 0.00 |
June | 409.76 | 59.42 | 325.81 | 87.64 | 238.17 | 0.00 | 0.00 |
July | 459.54 | 59.43 | 356.29 | 113.73 | 242.56 | 0.00 | 0.00 |
August | 477.55 | 69.69 | 380.26 | 159.70 | 220.56 | 0.00 | 0.00 |
September | 482.28 | 104.49 | 406.79 | 216.95 | 189.84 | 0.00 | 0.00 |
October | 373.92 | 146.97 | 346.73 | 203.90 | 142.83 | 0.00 | 0.00 |
November | 298.65 | 211.69 | 308.23 | 193.18 | 115.05 | 0.00 | 0.00 |
December | 277.08 | 330.26 | 327.84 | 214.64 | 113.21 | 0.00 | 0.00 |
Annual Sum or Average | 425.87 | 170.67 | 389.48 | 208.11 | 181.37 | 0.00 | 0.00 |
Minimum of Months | 277.08 | 59.42 | 308.23 | 87.64 | 113.21 | 0.00 | 0.00 |
Maximum of Months | 542.88 | 343.32 | 538.45 | 363.44 | 242.56 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LGSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.205533E+10 | 0.193765E+10 | 0.227953E+10 | 0.158387E+10 | 0.695664E+09 | 0.00 | 0.00 |
February | 0.262034E+10 | 0.144828E+10 | 0.261061E+10 | 0.176206E+10 | 0.848555E+09 | 0.00 | 0.00 |
March | 0.262232E+10 | 0.130118E+10 | 0.255274E+10 | 0.161637E+10 | 0.936371E+09 | 0.00 | 0.00 |
April | 0.248475E+10 | 0.845789E+09 | 0.224239E+10 | 0.121999E+10 | 0.102240E+10 | 0.00 | 0.00 |
May | 0.229969E+10 | 0.516750E+09 | 0.194900E+10 | 0.670510E+09 | 0.127849E+10 | 0.00 | 0.00 |
June | 0.210218E+10 | 0.345678E+09 | 0.169248E+10 | 0.455248E+09 | 0.123724E+10 | 0.00 | 0.00 |
July | 0.246540E+10 | 0.329087E+09 | 0.191251E+10 | 0.610488E+09 | 0.130202E+10 | 0.00 | 0.00 |
August | 0.255601E+10 | 0.392503E+09 | 0.204114E+10 | 0.857225E+09 | 0.118391E+10 | 0.00 | 0.00 |
September | 0.247222E+10 | 0.608436E+09 | 0.211312E+10 | 0.112698E+10 | 0.986137E+09 | 0.00 | 0.00 |
October | 0.196993E+10 | 0.902146E+09 | 0.186118E+10 | 0.109447E+10 | 0.766702E+09 | 0.00 | 0.00 |
November | 0.153363E+10 | 0.120193E+10 | 0.160115E+10 | 0.100353E+10 | 0.597621E+09 | 0.00 | 0.00 |
December | 0.147799E+10 | 0.186883E+10 | 0.175981E+10 | 0.115213E+10 | 0.607676E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.266598E+11 | 0.116983E+11 | 0.246157E+11 | 0.131529E+11 | 0.114628E+11 | 0.00 | 0.00 |
Minimum of Months | 0.147799E+10 | 0.329087E+09 | 0.160115E+10 | 0.455248E+09 | 0.597621E+09 | 0.00 | 0.00 |
Maximum of Months | 0.262232E+10 | 0.193765E+10 | 0.261061E+10 | 0.176206E+10 | 0.130202E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.101793E+10 | 0.997021E+09 | 0.113977E+10 | 0.791934E+09 | 0.347832E+09 | 0.00 | 0.00 |
February | 0.129926E+10 | 0.749583E+09 | 0.130531E+10 | 0.881030E+09 | 0.424277E+09 | 0.00 | 0.00 |
March | 0.130027E+10 | 0.677773E+09 | 0.127637E+10 | 0.808185E+09 | 0.468185E+09 | 0.00 | 0.00 |
April | 0.123475E+10 | 0.440956E+09 | 0.112120E+10 | 0.609993E+09 | 0.511202E+09 | 0.00 | 0.00 |
May | 0.114649E+10 | 0.263960E+09 | 0.974501E+09 | 0.335255E+09 | 0.639246E+09 | 0.00 | 0.00 |
June | 0.104705E+10 | 0.176737E+09 | 0.846242E+09 | 0.227624E+09 | 0.618618E+09 | 0.00 | 0.00 |
July | 0.122975E+10 | 0.167065E+09 | 0.956255E+09 | 0.305244E+09 | 0.651011E+09 | 0.00 | 0.00 |
August | 0.127504E+10 | 0.199491E+09 | 0.102057E+10 | 0.428612E+09 | 0.591957E+09 | 0.00 | 0.00 |
September | 0.123538E+10 | 0.307504E+09 | 0.105656E+10 | 0.563489E+09 | 0.493069E+09 | 0.00 | 0.00 |
October | 0.982695E+09 | 0.460192E+09 | 0.930588E+09 | 0.547236E+09 | 0.383351E+09 | 0.00 | 0.00 |
November | 0.758905E+09 | 0.625144E+09 | 0.800574E+09 | 0.501764E+09 | 0.298810E+09 | 0.00 | 0.00 |
December | 0.730725E+09 | 0.963427E+09 | 0.879904E+09 | 0.576066E+09 | 0.303838E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.132583E+11 | 0.602885E+10 | 0.123078E+11 | 0.657643E+10 | 0.573140E+10 | 0.00 | 0.00 |
Minimum of Months | 0.730725E+09 | 0.167065E+09 | 0.800574E+09 | 0.227624E+09 | 0.298810E+09 | 0.00 | 0.00 |
Maximum of Months | 0.130027E+10 | 0.997021E+09 | 0.130531E+10 | 0.881030E+09 | 0.651011E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.101601E+10 | 0.977169E+09 | 0.113743E+10 | 0.790309E+09 | 0.347119E+09 | 0.00 | 0.00 |
February | 0.129676E+10 | 0.735093E+09 | 0.130263E+10 | 0.879222E+09 | 0.423407E+09 | 0.00 | 0.00 |
March | 0.129755E+10 | 0.665033E+09 | 0.127375E+10 | 0.806527E+09 | 0.467225E+09 | 0.00 | 0.00 |
April | 0.123457E+10 | 0.428609E+09 | 0.111890E+10 | 0.608742E+09 | 0.510154E+09 | 0.00 | 0.00 |
May | 0.114672E+10 | 0.262793E+09 | 0.972502E+09 | 0.334567E+09 | 0.637935E+09 | 0.00 | 0.00 |
June | 0.104425E+10 | 0.182000E+09 | 0.844506E+09 | 0.227157E+09 | 0.617349E+09 | 0.00 | 0.00 |
July | 0.122364E+10 | 0.177297E+09 | 0.954294E+09 | 0.304618E+09 | 0.649676E+09 | 0.00 | 0.00 |
August | 0.127108E+10 | 0.208503E+09 | 0.101848E+10 | 0.427733E+09 | 0.590743E+09 | 0.00 | 0.00 |
September | 0.123543E+10 | 0.306707E+09 | 0.105439E+10 | 0.562333E+09 | 0.492057E+09 | 0.00 | 0.00 |
October | 0.984212E+09 | 0.446098E+09 | 0.928678E+09 | 0.546114E+09 | 0.382565E+09 | 0.00 | 0.00 |
November | 0.758490E+09 | 0.611013E+09 | 0.798932E+09 | 0.500735E+09 | 0.298197E+09 | 0.00 | 0.00 |
December | 0.729340E+09 | 0.944651E+09 | 0.878099E+09 | 0.574884E+09 | 0.303215E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.132381E+11 | 0.594497E+10 | 0.122826E+11 | 0.656294E+10 | 0.571964E+10 | 0.00 | 0.00 |
Minimum of Months | 0.729340E+09 | 0.177297E+09 | 0.798932E+09 | 0.227157E+09 | 0.298197E+09 | 0.00 | 0.00 |
Maximum of Months | 0.129755E+10 | 0.977169E+09 | 0.130263E+10 | 0.879222E+09 | 0.649676E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.101685E+10 | 0.970898E+09 | 0.113743E+10 | 0.790309E+09 | 0.347119E+09 | 0.00 | 0.00 |
February | 0.129777E+10 | 0.729681E+09 | 0.130263E+10 | 0.879222E+09 | 0.423407E+09 | 0.00 | 0.00 |
March | 0.129857E+10 | 0.659655E+09 | 0.127375E+10 | 0.806527E+09 | 0.467225E+09 | 0.00 | 0.00 |
April | 0.123625E+10 | 0.423250E+09 | 0.111890E+10 | 0.608742E+09 | 0.510154E+09 | 0.00 | 0.00 |
May | 0.114841E+10 | 0.259865E+09 | 0.972502E+09 | 0.334567E+09 | 0.637935E+09 | 0.00 | 0.00 |
June | 0.104501E+10 | 0.180946E+09 | 0.844506E+09 | 0.227157E+09 | 0.617349E+09 | 0.00 | 0.00 |
July | 0.122359E+10 | 0.177478E+09 | 0.954294E+09 | 0.304618E+09 | 0.649676E+09 | 0.00 | 0.00 |
August | 0.127124E+10 | 0.208249E+09 | 0.101848E+10 | 0.427733E+09 | 0.590743E+09 | 0.00 | 0.00 |
September | 0.123657E+10 | 0.304043E+09 | 0.105439E+10 | 0.562333E+09 | 0.492057E+09 | 0.00 | 0.00 |
October | 0.985875E+09 | 0.440384E+09 | 0.928678E+09 | 0.546114E+09 | 0.382565E+09 | 0.00 | 0.00 |
November | 0.759583E+09 | 0.604990E+09 | 0.798932E+09 | 0.500735E+09 | 0.298197E+09 | 0.00 | 0.00 |
December | 0.730035E+09 | 0.938442E+09 | 0.878099E+09 | 0.574884E+09 | 0.303215E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.132497E+11 | 0.589788E+10 | 0.122826E+11 | 0.656294E+10 | 0.571964E+10 | 0.00 | 0.00 |
Minimum of Months | 0.730035E+09 | 0.177478E+09 | 0.798932E+09 | 0.227157E+09 | 0.298197E+09 | 0.00 | 0.00 |
Maximum of Months | 0.129857E+10 | 0.970898E+09 | 0.130263E+10 | 0.879222E+09 | 0.649676E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.101781E+10 | 0.966906E+09 | 0.113743E+10 | 0.790309E+09 | 0.347119E+09 | 0.00 | 0.00 |
February | 0.129897E+10 | 0.725741E+09 | 0.130263E+10 | 0.879222E+09 | 0.423407E+09 | 0.00 | 0.00 |
March | 0.129982E+10 | 0.655419E+09 | 0.127375E+10 | 0.806527E+09 | 0.467225E+09 | 0.00 | 0.00 |
April | 0.123732E+10 | 0.420576E+09 | 0.111890E+10 | 0.608742E+09 | 0.510154E+09 | 0.00 | 0.00 |
May | 0.114929E+10 | 0.258368E+09 | 0.972502E+09 | 0.334567E+09 | 0.637935E+09 | 0.00 | 0.00 |
June | 0.104586E+10 | 0.179623E+09 | 0.844506E+09 | 0.227157E+09 | 0.617349E+09 | 0.00 | 0.00 |
July | 0.122432E+10 | 0.176172E+09 | 0.954294E+09 | 0.304618E+09 | 0.649676E+09 | 0.00 | 0.00 |
August | 0.127186E+10 | 0.206850E+09 | 0.101848E+10 | 0.427733E+09 | 0.590743E+09 | 0.00 | 0.00 |
September | 0.123680E+10 | 0.303364E+09 | 0.105439E+10 | 0.562333E+09 | 0.492057E+09 | 0.00 | 0.00 |
October | 0.986451E+09 | 0.438651E+09 | 0.928678E+09 | 0.546114E+09 | 0.382565E+09 | 0.00 | 0.00 |
November | 0.760754E+09 | 0.600647E+09 | 0.798932E+09 | 0.500735E+09 | 0.298197E+09 | 0.00 | 0.00 |
December | 0.730881E+09 | 0.934282E+09 | 0.878099E+09 | 0.574884E+09 | 0.303215E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.132601E+11 | 0.586660E+10 | 0.122826E+11 | 0.656294E+10 | 0.571964E+10 | 0.00 | 0.00 |
Minimum of Months | 0.730881E+09 | 0.176172E+09 | 0.798932E+09 | 0.227157E+09 | 0.298197E+09 | 0.00 | 0.00 |
Maximum of Months | 0.129982E+10 | 0.966906E+09 | 0.130263E+10 | 0.879222E+09 | 0.649676E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LGSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.204980E+10 | 0.190289E+10 | 0.227486E+10 | 0.158062E+10 | 0.694237E+09 | 0.00 | 0.00 |
February | 0.261350E+10 | 0.142587E+10 | 0.260526E+10 | 0.175844E+10 | 0.846814E+09 | 0.00 | 0.00 |
March | 0.261336E+10 | 0.128594E+10 | 0.254750E+10 | 0.161305E+10 | 0.934450E+09 | 0.00 | 0.00 |
April | 0.247727E+10 | 0.834163E+09 | 0.223779E+10 | 0.121748E+10 | 0.102031E+10 | 0.00 | 0.00 |
May | 0.229173E+10 | 0.515469E+09 | 0.194500E+10 | 0.669134E+09 | 0.127587E+10 | 0.00 | 0.00 |
June | 0.209060E+10 | 0.354439E+09 | 0.168901E+10 | 0.454314E+09 | 0.123470E+10 | 0.00 | 0.00 |
July | 0.244810E+10 | 0.345659E+09 | 0.190859E+10 | 0.609236E+09 | 0.129935E+10 | 0.00 | 0.00 |
August | 0.254365E+10 | 0.407360E+09 | 0.203695E+10 | 0.855466E+09 | 0.118149E+10 | 0.00 | 0.00 |
September | 0.246517E+10 | 0.612156E+09 | 0.210878E+10 | 0.112467E+10 | 0.984114E+09 | 0.00 | 0.00 |
October | 0.197071E+10 | 0.879380E+09 | 0.185736E+10 | 0.109223E+10 | 0.765130E+09 | 0.00 | 0.00 |
November | 0.153170E+10 | 0.117775E+10 | 0.159786E+10 | 0.100147E+10 | 0.596395E+09 | 0.00 | 0.00 |
December | 0.147401E+10 | 0.183610E+10 | 0.175620E+10 | 0.114977E+10 | 0.606430E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.265696E+11 | 0.115772E+11 | 0.245652E+11 | 0.131259E+11 | 0.114393E+11 | 0.00 | 0.00 |
Minimum of Months | 0.147401E+10 | 0.345659E+09 | 0.159786E+10 | 0.454314E+09 | 0.596395E+09 | 0.00 | 0.00 |
Maximum of Months | 0.261350E+10 | 0.190289E+10 | 0.260526E+10 | 0.175844E+10 | 0.129935E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.102135E+10 | 0.957321E+09 | 0.113743E+10 | 0.790309E+09 | 0.347119E+09 | 0.00 | 0.00 |
February | 0.130317E+10 | 0.716947E+09 | 0.130263E+10 | 0.879222E+09 | 0.423407E+09 | 0.00 | 0.00 |
March | 0.130381E+10 | 0.645864E+09 | 0.127375E+10 | 0.806527E+09 | 0.467225E+09 | 0.00 | 0.00 |
April | 0.124085E+10 | 0.412489E+09 | 0.111890E+10 | 0.608742E+09 | 0.510154E+09 | 0.00 | 0.00 |
May | 0.115165E+10 | 0.251888E+09 | 0.972502E+09 | 0.334567E+09 | 0.637935E+09 | 0.00 | 0.00 |
June | 0.104753E+10 | 0.174224E+09 | 0.844506E+09 | 0.227157E+09 | 0.617349E+09 | 0.00 | 0.00 |
July | 0.122436E+10 | 0.171163E+09 | 0.954294E+09 | 0.304618E+09 | 0.649676E+09 | 0.00 | 0.00 |
August | 0.127191E+10 | 0.201609E+09 | 0.101848E+10 | 0.427733E+09 | 0.590743E+09 | 0.00 | 0.00 |
September | 0.123743E+10 | 0.298013E+09 | 0.105439E+10 | 0.562333E+09 | 0.492057E+09 | 0.00 | 0.00 |
October | 0.988660E+09 | 0.431807E+09 | 0.928678E+09 | 0.546114E+09 | 0.382565E+09 | 0.00 | 0.00 |
November | 0.763977E+09 | 0.591264E+09 | 0.798932E+09 | 0.500735E+09 | 0.298197E+09 | 0.00 | 0.00 |
December | 0.734041E+09 | 0.924413E+09 | 0.878099E+09 | 0.574884E+09 | 0.303215E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.132887E+11 | 0.577700E+10 | 0.122826E+11 | 0.656294E+10 | 0.571964E+10 | 0.00 | 0.00 |
Minimum of Months | 0.734041E+09 | 0.171163E+09 | 0.798932E+09 | 0.227157E+09 | 0.298197E+09 | 0.00 | 0.00 |
Maximum of Months | 0.130381E+10 | 0.957321E+09 | 0.130263E+10 | 0.879222E+09 | 0.649676E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.102154E+10 | 0.956520E+09 | 0.113743E+10 | 0.790309E+09 | 0.347119E+09 | 0.00 | 0.00 |
February | 0.130351E+10 | 0.715849E+09 | 0.130263E+10 | 0.879222E+09 | 0.423407E+09 | 0.00 | 0.00 |
March | 0.130433E+10 | 0.644204E+09 | 0.127375E+10 | 0.806527E+09 | 0.467225E+09 | 0.00 | 0.00 |
April | 0.124279E+10 | 0.408661E+09 | 0.111890E+10 | 0.608742E+09 | 0.510154E+09 | 0.00 | 0.00 |
May | 0.115477E+10 | 0.248263E+09 | 0.972502E+09 | 0.334567E+09 | 0.637935E+09 | 0.00 | 0.00 |
June | 0.104970E+10 | 0.172059E+09 | 0.844506E+09 | 0.227157E+09 | 0.617349E+09 | 0.00 | 0.00 |
July | 0.122522E+10 | 0.170237E+09 | 0.954294E+09 | 0.304618E+09 | 0.649676E+09 | 0.00 | 0.00 |
August | 0.127282E+10 | 0.200316E+09 | 0.101848E+10 | 0.427733E+09 | 0.590743E+09 | 0.00 | 0.00 |
September | 0.123973E+10 | 0.294085E+09 | 0.105439E+10 | 0.562333E+09 | 0.492057E+09 | 0.00 | 0.00 |
October | 0.990542E+09 | 0.427437E+09 | 0.928678E+09 | 0.546114E+09 | 0.382565E+09 | 0.00 | 0.00 |
November | 0.764564E+09 | 0.589271E+09 | 0.798932E+09 | 0.500735E+09 | 0.298197E+09 | 0.00 | 0.00 |
December | 0.734234E+09 | 0.923491E+09 | 0.878099E+09 | 0.574884E+09 | 0.303215E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.133038E+11 | 0.575039E+10 | 0.122826E+11 | 0.656294E+10 | 0.571964E+10 | 0.00 | 0.00 |
Minimum of Months | 0.734234E+09 | 0.170237E+09 | 0.798932E+09 | 0.227157E+09 | 0.298197E+09 | 0.00 | 0.00 |
Maximum of Months | 0.130433E+10 | 0.956520E+09 | 0.130263E+10 | 0.879222E+09 | 0.649676E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.102273E+10 | 0.950619E+09 | 0.113743E+10 | 0.790309E+09 | 0.347119E+09 | 0.00 | 0.00 |
February | 0.130514E+10 | 0.709425E+09 | 0.130263E+10 | 0.879222E+09 | 0.423407E+09 | 0.00 | 0.00 |
March | 0.130653E+10 | 0.635863E+09 | 0.127375E+10 | 0.806527E+09 | 0.467225E+09 | 0.00 | 0.00 |
April | 0.124670E+10 | 0.399445E+09 | 0.111890E+10 | 0.608742E+09 | 0.510154E+09 | 0.00 | 0.00 |
May | 0.116004E+10 | 0.241577E+09 | 0.972502E+09 | 0.334567E+09 | 0.637935E+09 | 0.00 | 0.00 |
June | 0.105365E+10 | 0.167740E+09 | 0.844506E+09 | 0.227157E+09 | 0.617349E+09 | 0.00 | 0.00 |
July | 0.122704E+10 | 0.167965E+09 | 0.954294E+09 | 0.304618E+09 | 0.649676E+09 | 0.00 | 0.00 |
August | 0.127466E+10 | 0.197366E+09 | 0.101848E+10 | 0.427733E+09 | 0.590743E+09 | 0.00 | 0.00 |
September | 0.124293E+10 | 0.288357E+09 | 0.105439E+10 | 0.562333E+09 | 0.492057E+09 | 0.00 | 0.00 |
October | 0.993465E+09 | 0.419689E+09 | 0.928678E+09 | 0.546114E+09 | 0.382565E+09 | 0.00 | 0.00 |
November | 0.766598E+09 | 0.581178E+09 | 0.798932E+09 | 0.500735E+09 | 0.298197E+09 | 0.00 | 0.00 |
December | 0.735369E+09 | 0.916945E+09 | 0.878099E+09 | 0.574884E+09 | 0.303215E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.133349E+11 | 0.567617E+10 | 0.122826E+11 | 0.656294E+10 | 0.571964E+10 | 0.00 | 0.00 |
Minimum of Months | 0.735369E+09 | 0.167740E+09 | 0.798932E+09 | 0.227157E+09 | 0.298197E+09 | 0.00 | 0.00 |
Maximum of Months | 0.130653E+10 | 0.950619E+09 | 0.130263E+10 | 0.879222E+09 | 0.649676E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE8
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.103059E+10 | 0.919560E+09 | 0.113743E+10 | 0.790309E+09 | 0.347119E+09 | 0.00 | 0.00 |
February | 0.131333E+10 | 0.680137E+09 | 0.130263E+10 | 0.879222E+09 | 0.423407E+09 | 0.00 | 0.00 |
March | 0.131591E+10 | 0.599146E+09 | 0.127375E+10 | 0.806527E+09 | 0.467225E+09 | 0.00 | 0.00 |
April | 0.125775E+10 | 0.365564E+09 | 0.111890E+10 | 0.608742E+09 | 0.510154E+09 | 0.00 | 0.00 |
May | 0.117276E+10 | 0.220330E+09 | 0.972502E+09 | 0.334567E+09 | 0.637935E+09 | 0.00 | 0.00 |
June | 0.106209E+10 | 0.154010E+09 | 0.844506E+09 | 0.227157E+09 | 0.617349E+09 | 0.00 | 0.00 |
July | 0.123083E+10 | 0.159188E+09 | 0.954294E+09 | 0.304618E+09 | 0.649676E+09 | 0.00 | 0.00 |
August | 0.127907E+10 | 0.186665E+09 | 0.101848E+10 | 0.427733E+09 | 0.590743E+09 | 0.00 | 0.00 |
September | 0.125008E+10 | 0.270846E+09 | 0.105439E+10 | 0.562333E+09 | 0.492057E+09 | 0.00 | 0.00 |
October | 0.100152E+10 | 0.393632E+09 | 0.928678E+09 | 0.546114E+09 | 0.382565E+09 | 0.00 | 0.00 |
November | 0.774090E+09 | 0.548691E+09 | 0.798932E+09 | 0.500735E+09 | 0.298197E+09 | 0.00 | 0.00 |
December | 0.742118E+09 | 0.884565E+09 | 0.878099E+09 | 0.574884E+09 | 0.303215E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.134301E+11 | 0.538233E+10 | 0.122826E+11 | 0.656294E+10 | 0.571964E+10 | 0.00 | 0.00 |
Minimum of Months | 0.742118E+09 | 0.154010E+09 | 0.798932E+09 | 0.227157E+09 | 0.298197E+09 | 0.00 | 0.00 |
Maximum of Months | 0.131591E+10 | 0.919560E+09 | 0.130263E+10 | 0.879222E+09 | 0.649676E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | -16.9 | -17.4 | -20.0 | 3.73 | -31.9 | 33.25 | 98.18 | 0.00 |
February | -11.6 | -12.7 | -16.7 | 4.33 | -26.7 | 48.91 | 138.70 | 0.00 |
March | -6.2 | -7.6 | -10.8 | 3.55 | -19.4 | 56.69 | 163.76 | 0.01 |
April | 3.97 | 0.41 | -4.8 | 4.72 | -9.1 | 70.41 | 207.70 | 0.01 |
May | 13.43 | 8.45 | 3.53 | 3.60 | 2.20 | 102.27 | 202.62 | 0.00 |
June | 18.03 | 14.19 | 11.55 | 3.74 | 7.84 | 104.36 | 210.60 | 0.06 |
July | 19.67 | 16.51 | 14.78 | 3.14 | 8.97 | 101.67 | 223.82 | 0.04 |
August | 17.94 | 15.20 | 13.59 | 3.45 | 8.99 | 87.39 | 175.79 | 0.04 |
September | 12.29 | 9.87 | 7.80 | 3.78 | 3.34 | 70.27 | 143.96 | 0.00 |
October | 5.42 | 3.47 | 1.07 | 3.53 | -4.7 | 51.74 | 90.11 | 0.00 |
November | -2.0 | -3.6 | -6.9 | 4.42 | -13.7 | 34.68 | 65.95 | 0.00 |
December | -14.6 | -15.1 | -18.1 | 3.91 | -28.3 | 29.58 | 68.99 | 0.00 |
Annual Sum or Average | 3.36 | 1.04 | -2.0 | 3.82 | -8.4 | 66.03 | 149.18 | 0.01 |
Minimum of Months | -16.9 | -17.4 | -20.0 | 3.14 | -31.9 | 29.58 | 65.95 | 0.00 |
Maximum of Months | 19.67 | 16.51 | 14.78 | 4.72 | 8.99 | 104.36 | 223.82 | 0.06 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 1.10 | 29-JAN-14:00 | -1.0 | -4.4 | 2.60 | -11.4 | 145.00 | 110.00 |
February | 8.90 | 20-FEB-15:00 | 2.87 | -6.7 | 8.80 | -9.0 | 49.00 | 646.00 |
March | 11.10 | 26-MAR-15:00 | 5.48 | -1.1 | 5.20 | -5.7 | 53.00 | 842.00 |
April | 26.70 | 23-APR-15:00 | 16.95 | 11.10 | 11.30 | 12.03 | 75.50 | 811.00 |
May | 29.40 | 25-MAY-17:00 | 19.26 | 13.90 | 1.50 | 16.49 | 47.50 | 582.00 |
June | 35.00 | 29-JUN-15:00 | 24.72 | 21.10 | 6.70 | 24.66 | 132.00 | 705.00 |
July | 31.10 | 15-JUL-14:20 | 25.35 | 23.33 | 8.07 | 19.93 | 299.67 | 518.33 |
August | 30.60 | 08-AUG-14:00 | 23.36 | 20.60 | 6.70 | 17.93 | 163.50 | 672.50 |
September | 26.10 | 01-SEP-14:00 | 17.82 | 13.30 | 3.60 | 14.28 | 112.00 | 751.50 |
October | 22.20 | 19-OCT-14:00 | 13.62 | 7.20 | 6.70 | 8.15 | 35.50 | 701.50 |
November | 18.30 | 01-NOV-14:00 | 13.44 | 10.00 | 3.10 | 11.84 | 105.00 | 30.50 |
December | 1.10 | 28-DEC-02:00 | 0.43 | -0.6 | 4.60 | -5.5 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 1.10 | -1.0 | -6.7 | 1.50 | -11.4 | 0.00 | 0.00 | |
Maximum of Months | 35.00 | 25.35 | 23.33 | 11.30 | 24.66 | 299.67 | 842.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -35.6 | 06-JAN-08:00 | -35.7 | -37.8 | 0.00 | -57.8 | 27.00 | 381.00 |
February | -33.3 | 14-FEB-06:00 | -33.4 | -36.7 | 0.00 | -55.6 | 0.00 | 0.00 |
March | -28.9 | 05-MAR-06:00 | -29.1 | -32.2 | 1.50 | -50.6 | 27.00 | 41.50 |
April | -13.9 | 05-APR-05:00 | -14.4 | -16.1 | 0.00 | -32.5 | 14.50 | 199.00 |
May | -3.9 | 01-MAY-05:00 | -6.2 | -12.2 | 0.00 | -22.4 | 35.00 | 415.00 |
June | 1.10 | 04-JUN-04:00 | 0.62 | 0.00 | 0.00 | -14.9 | 37.00 | 169.50 |
July | 6.10 | 02-JUL-04:00 | 6.10 | 6.10 | 0.00 | -8.8 | 33.50 | 204.50 |
August | 4.40 | 19-AUG-03:00 | 4.40 | 4.40 | 0.00 | -10.7 | 0.00 | 0.00 |
September | 1.10 | 06-SEP-03:00 | 1.10 | 1.10 | 0.00 | -14.7 | 0.00 | 0.00 |
October | -10.0 | 30-OCT-03:00 | -10.7 | -12.8 | 1.50 | -28.2 | 0.00 | 0.00 |
November | -20.6 | 29-NOV-05:00 | -20.8 | -22.2 | 2.10 | -37.8 | 0.00 | 0.00 |
December | -31.1 | 24-DEC-06:19 | -31.3 | -35.1 | 3.33 | -53.1 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -35.6 | -35.7 | -37.8 | 0.00 | -57.8 | 0.00 | 0.00 | |
Maximum of Months | 6.10 | 6.10 | 6.10 | 3.33 | -8.8 | 37.00 | 415.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -0.5 | 16-JAN-12:00 | 0.00 | -1.1 | 5.70 | -6.6 | 172.50 | 3.00 |
February | 3.34 | 21-FEB-12:00 | 6.70 | -1.1 | 7.70 | -6.0 | 270.00 | 303.00 |
March | 5.48 | 26-MAR-15:00 | 11.10 | -1.1 | 5.20 | -5.7 | 53.00 | 842.00 |
April | 16.95 | 23-APR-15:00 | 26.70 | 11.10 | 11.30 | 12.03 | 75.50 | 811.00 |
May | 19.91 | 26-MAY-11:00 | 25.60 | 17.20 | 6.20 | 22.64 | 300.50 | 6.00 |
June | 24.72 | 29-JUN-15:00 | 35.00 | 21.10 | 6.70 | 24.66 | 132.00 | 705.00 |
July | 25.76 | 15-JUL-13:00 | 31.10 | 23.90 | 7.70 | 18.99 | 333.00 | 421.00 |
August | 23.36 | 08-AUG-14:00 | 30.60 | 20.60 | 6.70 | 17.93 | 163.50 | 672.50 |
September | 18.67 | 01-SEP-00:00 | 19.00 | 17.50 | 2.80 | 16.30 | 0.00 | 0.00 |
October | 13.72 | 19-OCT-13:00 | 21.70 | 7.80 | 5.70 | 7.75 | 54.50 | 739.00 |
November | 14.29 | 21-NOV-12:00 | 15.00 | 13.90 | 5.20 | 11.46 | 134.50 | 25.50 |
December | 0.43 | 28-DEC-02:00 | 1.10 | -0.6 | 4.60 | -5.5 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -0.5 | 0.00 | -1.1 | 2.80 | -6.6 | 0.00 | 0.00 | |
Maximum of Months | 25.76 | 35.00 | 23.90 | 11.30 | 24.66 | 333.00 | 842.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -1.1 | 16-JAN-11:00 | -0.6 | -0.8 | 5.70 | -7.3 | 164.50 | 5.00 |
February | -0.6 | 21-FEB-08:00 | 4.40 | 2.25 | 8.80 | -6.6 | 123.00 | 89.50 |
March | 0.00 | 29-MAR-20:00 | 1.70 | 0.95 | 1.50 | -4.8 | 0.00 | 0.00 |
April | 11.10 | 23-APR-13:00 | 24.40 | 16.08 | 10.80 | 9.72 | 98.50 | 903.50 |
May | 17.20 | 26-MAY-11:00 | 25.60 | 19.91 | 6.20 | 22.64 | 300.50 | 6.00 |
June | 22.80 | 29-JUN-23:19 | 26.30 | 23.71 | 5.20 | 14.28 | 0.00 | 0.00 |
July | 23.90 | 15-JUL-13:00 | 31.10 | 25.76 | 7.70 | 18.99 | 333.00 | 421.00 |
August | 20.60 | 08-AUG-14:00 | 30.60 | 23.36 | 6.70 | 17.93 | 163.50 | 672.50 |
September | 17.92 | 01-SEP-00:10 | 19.75 | 18.15 | 3.22 | 13.23 | 0.00 | 0.00 |
October | 12.20 | 07-OCT-12:20 | 14.47 | 13.17 | 3.43 | 9.20 | 163.17 | 18.50 |
November | 13.90 | 21-NOV-12:00 | 15.00 | 14.29 | 5.20 | 11.46 | 134.50 | 25.50 |
December | -0.0 | 05-DEC-17:00 | 0.00 | -0.0 | 1.50 | -6.4 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -1.1 | -0.6 | -0.8 | 1.50 | -7.3 | 0.00 | 0.00 | |
Maximum of Months | 23.90 | 31.10 | 25.76 | 10.80 | 22.64 | 333.00 | 903.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 1.89 | 11.66 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 0.58 | 19.92 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 0.81 | 26.63 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 2.58 | 37.52 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 5.43 | 45.25 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 8.61 | 47.76 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 11.25 | 48.86 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 12.66 | 38.94 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 12.41 | 29.23 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 10.60 | 17.37 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 7.72 | 10.89 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 4.55 | 9.11 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 6.63 | 28.63 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 0.58 | 9.11 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 12.66 | 48.86 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.407722E+09 | -280357228.5 | 0.00 | 0.00 | 744.00 | 0.00 | -127364711.2 | 59.00 | 0.00 | 0.00 |
February | 0.375087E+09 | -260412120.1 | 0.00 | 0.00 | 672.00 | 0.00 | -114674980.2 | 59.00 | 0.00 | 0.00 |
March | 0.417731E+09 | -291903754.5 | 0.00 | 0.00 | 744.00 | 0.00 | -125827037.8 | 58.99 | 0.00 | 0.00 |
April | 0.388147E+09 | -270394244.8 | 0.00 | 0.00 | 720.00 | 0.00 | -117752890.5 | 58.99 | 0.00 | 0.00 |
May | 0.380742E+09 | -265734848.5 | 0.00 | 0.00 | 744.00 | 0.00 | -115007393.1 | 58.99 | 0.00 | 0.00 |
June | 0.353960E+09 | -244325424.4 | 0.00 | 0.00 | 720.00 | 0.00 | -109634364.7 | 59.00 | 0.00 | 0.00 |
July | 0.346905E+09 | -234335595.0 | 0.00 | 0.00 | 744.00 | 0.00 | -112569686.4 | 58.99 | 0.00 | 0.00 |
August | 0.344991E+09 | -232289156.7 | 0.00 | 0.00 | 744.00 | 0.00 | -112701836.5 | 58.99 | 0.00 | 0.00 |
September | 0.333779E+09 | -223461043.7 | 0.00 | 0.00 | 720.00 | 0.00 | -110318305.5 | 58.99 | 0.00 | 0.00 |
October | 0.356982E+09 | -237649533.1 | 0.00 | 0.00 | 744.00 | 0.00 | -119332373.1 | 58.99 | 0.00 | 0.00 |
November | 0.363703E+09 | -242955494.7 | 0.00 | 0.00 | 720.00 | 0.00 | -120747292.6 | 58.99 | 0.00 | 0.00 |
December | 0.394764E+09 | -267642067.1 | 0.00 | 0.00 | 744.00 | 0.00 | -127121467.8 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.446451E+10 | -0.305146E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.141305E+10 | 58.99 | 0.00 | 0.00 |
Minimum of Months | 0.333779E+09 | -291903754.5 | 0.00 | 0.00 | 672.00 | 0.00 | -127364711.2 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.417731E+09 | -223461043.7 | 0.00 | 0.00 | 744.00 | 0.00 | -109634364.7 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.406413E+09 | -280357698.0 | 0.00 | 0.00 | 744.00 | 0.00 | -126055116.4 | 59.00 | 0.00 | 0.00 |
February | 0.373630E+09 | -260418655.9 | 0.00 | 0.00 | 672.00 | 0.00 | -113210972.2 | 58.99 | 0.00 | 0.00 |
March | 0.416069E+09 | -291899154.6 | 0.00 | 0.00 | 744.00 | 0.00 | -124169514.5 | 58.99 | 0.00 | 0.00 |
April | 0.386980E+09 | -270389069.4 | 0.00 | 0.00 | 720.00 | 0.00 | -116591127.3 | 58.99 | 0.00 | 0.00 |
May | 0.380574E+09 | -265734809.0 | 0.00 | 0.00 | 744.00 | 0.00 | -114839561.6 | 58.99 | 0.00 | 0.00 |
June | 0.353611E+09 | -244339452.1 | 0.00 | 0.00 | 720.00 | 0.00 | -109271126.8 | 58.99 | 0.00 | 0.00 |
July | 0.346654E+09 | -234331896.2 | 0.00 | 0.00 | 744.00 | 0.00 | -112322166.2 | 58.99 | 0.00 | 0.00 |
August | 0.344730E+09 | -232300337.8 | 0.00 | 0.00 | 744.00 | 0.00 | -112429565.4 | 58.99 | 0.00 | 0.00 |
September | 0.333935E+09 | -223459950.6 | 0.00 | 0.00 | 720.00 | 0.00 | -110474712.9 | 58.99 | 0.00 | 0.00 |
October | 0.356715E+09 | -237650163.7 | 0.00 | 0.00 | 744.00 | 0.00 | -119064854.9 | 58.99 | 0.00 | 0.00 |
November | 0.362148E+09 | -242952256.9 | 0.00 | 0.00 | 720.00 | 0.00 | -119195676.7 | 58.99 | 0.00 | 0.00 |
December | 0.393402E+09 | -267642262.7 | 0.00 | 0.00 | 744.00 | 0.00 | -125759783.9 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.445486E+10 | -0.305148E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.140338E+10 | 58.99 | 0.00 | 0.00 |
Minimum of Months | 0.333935E+09 | -291899154.6 | 0.00 | 0.00 | 672.00 | 0.00 | -126055116.4 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.416069E+09 | -223459950.6 | 0.00 | 0.00 | 744.00 | 0.00 | -109271126.8 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.374705E+09 | -246546493.7 | 0.00 | 0.00 | 744.00 | 0.00 | -128158461.0 | 58.99 | 0.00 | 0.00 |
February | 0.344012E+09 | -229184282.0 | 0.00 | 0.00 | 672.00 | 0.00 | -114828090.0 | 58.99 | 0.00 | 0.00 |
March | 0.386218E+09 | -260506493.3 | 0.00 | 0.00 | 744.00 | 0.00 | -125711052.5 | 59.00 | 0.00 | 0.00 |
April | 0.356105E+09 | -237810565.9 | 0.00 | 0.00 | 720.00 | 0.00 | -118294326.8 | 58.99 | 0.00 | 0.00 |
May | 0.350955E+09 | -235692240.8 | 0.00 | 0.00 | 744.00 | 0.00 | -115263115.6 | 58.99 | 0.00 | 0.00 |
June | 0.326242E+09 | -217614824.8 | 0.00 | 0.00 | 720.00 | 0.00 | -108626720.4 | 58.98 | 0.00 | 0.00 |
July | 0.315723E+09 | -204846568.3 | 0.00 | 0.00 | 744.00 | 0.00 | -110876294.8 | 58.99 | 0.00 | 0.00 |
August | 0.318883E+09 | -207492668.3 | 0.00 | 0.00 | 744.00 | 0.00 | -111389982.5 | 58.99 | 0.00 | 0.00 |
September | 0.307282E+09 | -196397893.2 | 0.00 | 0.00 | 720.00 | 0.00 | -110883696.6 | 58.99 | 0.00 | 0.00 |
October | 0.329946E+09 | -208997929.3 | 0.00 | 0.00 | 744.00 | 0.00 | -120948029.6 | 59.00 | 0.00 | 0.00 |
November | 0.335400E+09 | -214505752.3 | 0.00 | 0.00 | 720.00 | 0.00 | -120894234.5 | 58.99 | 0.00 | 0.00 |
December | 0.361435E+09 | -233641842.2 | 0.00 | 0.00 | 744.00 | 0.00 | -127792721.9 | 58.98 | 0.00 | 0.00 |
Annual Sum or Average | 0.410690E+10 | -0.269324E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.141367E+10 | 58.99 | 0.00 | 0.00 |
Minimum of Months | 0.307282E+09 | -260506493.3 | 0.00 | 0.00 | 672.00 | 0.00 | -128158461.0 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.386218E+09 | -196397893.2 | 0.00 | 0.00 | 744.00 | 0.00 | -108626720.4 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.375109E+09 | -246542770.5 | 0.00 | 0.00 | 744.00 | 0.00 | -128566050.2 | 59.00 | 0.00 | 0.00 |
February | 0.344385E+09 | -229181090.8 | 0.00 | 0.00 | 672.00 | 0.00 | -115203841.4 | 58.99 | 0.00 | 0.00 |
March | 0.386578E+09 | -260514028.7 | 0.00 | 0.00 | 744.00 | 0.00 | -126064171.1 | 58.99 | 0.00 | 0.00 |
April | 0.356538E+09 | -237817090.5 | 0.00 | 0.00 | 720.00 | 0.00 | -118721210.8 | 58.99 | 0.00 | 0.00 |
May | 0.351271E+09 | -235694957.5 | 0.00 | 0.00 | 744.00 | 0.00 | -115575743.2 | 58.99 | 0.00 | 0.00 |
June | 0.326385E+09 | -217573131.1 | 0.00 | 0.00 | 720.00 | 0.00 | -108812351.1 | 59.00 | 0.00 | 0.00 |
July | 0.315707E+09 | -204851342.7 | 0.00 | 0.00 | 744.00 | 0.00 | -110855584.7 | 58.99 | 0.00 | 0.00 |
August | 0.318916E+09 | -207484198.1 | 0.00 | 0.00 | 744.00 | 0.00 | -111431543.2 | 58.99 | 0.00 | 0.00 |
September | 0.307539E+09 | -196392861.2 | 0.00 | 0.00 | 720.00 | 0.00 | -111145696.9 | 58.99 | 0.00 | 0.00 |
October | 0.330412E+09 | -208970050.2 | 0.00 | 0.00 | 744.00 | 0.00 | -121442077.8 | 59.01 | 0.00 | 0.00 |
November | 0.335810E+09 | -214517028.4 | 0.00 | 0.00 | 720.00 | 0.00 | -121293150.1 | 58.99 | 0.00 | 0.00 |
December | 0.361832E+09 | -233620705.4 | 0.00 | 0.00 | 744.00 | 0.00 | -128211134.8 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.411048E+10 | -0.269316E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.141732E+10 | 58.99 | 0.00 | 0.00 |
Minimum of Months | 0.307539E+09 | -260514028.7 | 0.00 | 0.00 | 672.00 | 0.00 | -128566050.2 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.386578E+09 | -196392861.2 | 0.00 | 0.00 | 744.00 | 0.00 | -108812351.1 | 59.01 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.363104E+09 | -233025464.7 | 0.00 | 0.00 | 744.00 | 0.00 | -130078399.4 | 58.99 | 0.00 | 0.00 |
February | 0.333401E+09 | -216711296.4 | 0.00 | 0.00 | 672.00 | 0.00 | -116689938.3 | 59.00 | 0.00 | 0.00 |
March | 0.373996E+09 | -246494761.2 | 0.00 | 0.00 | 744.00 | 0.00 | -127501461.2 | 58.99 | 0.00 | 0.00 |
April | 0.343930E+09 | -225031022.9 | 0.00 | 0.00 | 720.00 | 0.00 | -118898809.9 | 59.00 | 0.00 | 0.00 |
May | 0.338045E+09 | -222888606.3 | 0.00 | 0.00 | 744.00 | 0.00 | -115156186.5 | 59.00 | 0.00 | 0.00 |
June | 0.314931E+09 | -205869882.6 | 0.00 | 0.00 | 720.00 | 0.00 | -109061610.1 | 59.00 | 0.00 | 0.00 |
July | 0.305028E+09 | -193738348.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111289451.7 | 58.99 | 0.00 | 0.00 |
August | 0.308115E+09 | -196325900.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111789066.5 | 59.00 | 0.00 | 0.00 |
September | 0.296079E+09 | -185845541.9 | 0.00 | 0.00 | 720.00 | 0.00 | -110233490.9 | 58.99 | 0.00 | 0.00 |
October | 0.318400E+09 | -197541521.1 | 0.00 | 0.00 | 744.00 | 0.00 | -120858556.7 | 58.99 | 0.00 | 0.00 |
November | 0.325138E+09 | -202626648.9 | 0.00 | 0.00 | 720.00 | 0.00 | -122511125.5 | 58.98 | 0.00 | 0.00 |
December | 0.350684E+09 | -220937673.0 | 0.00 | 0.00 | 744.00 | 0.00 | -129746683.1 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.397085E+10 | -0.254704E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.142381E+10 | 58.99 | 0.00 | 0.00 |
Minimum of Months | 0.296079E+09 | -246494761.2 | 0.00 | 0.00 | 672.00 | 0.00 | -130078399.4 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.373996E+09 | -185845541.9 | 0.00 | 0.00 | 744.00 | 0.00 | -109061610.1 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.362946E+09 | -233032732.6 | 0.00 | 0.00 | 744.00 | 0.00 | -129913544.0 | 58.99 | 0.00 | 0.00 |
February | 0.333269E+09 | -216717557.6 | 0.00 | 0.00 | 672.00 | 0.00 | -116551108.0 | 59.00 | 0.00 | 0.00 |
March | 0.373932E+09 | -246498321.5 | 0.00 | 0.00 | 744.00 | 0.00 | -127433693.5 | 58.99 | 0.00 | 0.00 |
April | 0.344905E+09 | -225040296.5 | 0.00 | 0.00 | 720.00 | 0.00 | -119864234.8 | 58.99 | 0.00 | 0.00 |
May | 0.339362E+09 | -222919035.5 | 0.00 | 0.00 | 744.00 | 0.00 | -116443434.3 | 58.98 | 0.00 | 0.00 |
June | 0.315433E+09 | -205884469.9 | 0.00 | 0.00 | 720.00 | 0.00 | -109548071.4 | 58.99 | 0.00 | 0.00 |
July | 0.305227E+09 | -193726226.7 | 0.00 | 0.00 | 744.00 | 0.00 | -111500943.9 | 58.99 | 0.00 | 0.00 |
August | 0.308375E+09 | -196327653.9 | 0.00 | 0.00 | 744.00 | 0.00 | -112047562.9 | 58.99 | 0.00 | 0.00 |
September | 0.297569E+09 | -185854402.1 | 0.00 | 0.00 | 720.00 | 0.00 | -111714779.8 | 58.99 | 0.00 | 0.00 |
October | 0.319784E+09 | -197528132.6 | 0.00 | 0.00 | 744.00 | 0.00 | -122255468.6 | 59.00 | 0.00 | 0.00 |
November | 0.325171E+09 | -202573723.3 | 0.00 | 0.00 | 720.00 | 0.00 | -122596835.8 | 59.00 | 0.00 | 0.00 |
December | 0.350530E+09 | -220934161.4 | 0.00 | 0.00 | 744.00 | 0.00 | -129596024.1 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.397650E+10 | -0.254704E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.142947E+10 | 58.99 | 0.00 | 0.00 |
Minimum of Months | 0.297569E+09 | -246498321.5 | 0.00 | 0.00 | 672.00 | 0.00 | -129913544.0 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.373932E+09 | -185854402.1 | 0.00 | 0.00 | 744.00 | 0.00 | -109548071.4 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.362989E+09 | -233030325.2 | 0.00 | 0.00 | 744.00 | 0.00 | -129958526.7 | 58.99 | 0.00 | 0.00 |
February | 0.333342E+09 | -216714779.8 | 0.00 | 0.00 | 672.00 | 0.00 | -116627373.8 | 59.00 | 0.00 | 0.00 |
March | 0.374041E+09 | -246488635.8 | 0.00 | 0.00 | 744.00 | 0.00 | -127552754.0 | 59.00 | 0.00 | 0.00 |
April | 0.345248E+09 | -225033203.2 | 0.00 | 0.00 | 720.00 | 0.00 | -120214376.2 | 59.00 | 0.00 | 0.00 |
May | 0.339812E+09 | -222901737.7 | 0.00 | 0.00 | 744.00 | 0.00 | -116910733.6 | 58.99 | 0.00 | 0.00 |
June | 0.315707E+09 | -205896508.9 | 0.00 | 0.00 | 720.00 | 0.00 | -109810354.0 | 58.99 | 0.00 | 0.00 |
July | 0.305332E+09 | -193725748.2 | 0.00 | 0.00 | 744.00 | 0.00 | -111606558.2 | 58.99 | 0.00 | 0.00 |
August | 0.308504E+09 | -196330192.8 | 0.00 | 0.00 | 744.00 | 0.00 | -112174045.5 | 58.99 | 0.00 | 0.00 |
September | 0.297983E+09 | -185852234.6 | 0.00 | 0.00 | 720.00 | 0.00 | -112131090.0 | 58.99 | 0.00 | 0.00 |
October | 0.320139E+09 | -197548687.2 | 0.00 | 0.00 | 744.00 | 0.00 | -122590562.2 | 58.99 | 0.00 | 0.00 |
November | 0.325304E+09 | -202573760.5 | 0.00 | 0.00 | 720.00 | 0.00 | -122730047.3 | 59.00 | 0.00 | 0.00 |
December | 0.350582E+09 | -220933997.0 | 0.00 | 0.00 | 744.00 | 0.00 | -129648263.9 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.397898E+10 | -0.254703E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.143195E+10 | 58.99 | 0.00 | 0.00 |
Minimum of Months | 0.297983E+09 | -246488635.8 | 0.00 | 0.00 | 672.00 | 0.00 | -129958526.7 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.374041E+09 | -185852234.6 | 0.00 | 0.00 | 744.00 | 0.00 | -109810354.0 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 243.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 265.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 254.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 296.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 437.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 401.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 409.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 352.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 344.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 299.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 255.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 226.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3785.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 226.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 437.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_1:1 HEATING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.289907E+11 | 70101.09 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.161205E+11 | 70101.09 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.115427E+11 | 70101.09 | 01-MAR-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.281610E+10 | 70101.09 | 01-APR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 31410602.30 | 70101.09 | 01-MAY-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.115941E+10 | 70101.09 | 06-OCT-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.767248E+10 | 70101.09 | 03-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.253160E+11 | 70101.09 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.936493E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.289907E+11 | 70101.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_2:2 HEATING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.163496E+11 | 36304.10 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.106065E+11 | 36304.10 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.860381E+10 | 36304.10 | 01-MAR-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.257481E+10 | 36304.10 | 02-APR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 52817405.34 | 18375.18 | 01-MAY-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 1269310.33 | 457.01 | 28-SEP-08:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.179280E+10 | 36304.10 | 30-OCT-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.636868E+10 | 36304.10 | 04-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.151288E+11 | 36304.10 | 01-DEC-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.614792E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.163496E+11 | 36304.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_3:3 HEATING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.177869E+11 | 36270.68 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.119220E+11 | 36270.68 | 01-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.995217E+10 | 36270.68 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.337568E+10 | 36270.68 | 02-APR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.165351E+09 | 27167.96 | 01-MAY-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 49278966.39 | 3110.09 | 23-SEP-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.263795E+10 | 36270.68 | 30-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.753771E+10 | 36270.68 | 05-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.164734E+11 | 36270.68 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.699004E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.177869E+11 | 36270.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_4:4 HEATING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.180803E+11 | 36346.02 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.121325E+11 | 36346.02 | 01-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.101593E+11 | 36346.02 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.353392E+10 | 36346.02 | 02-APR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.201652E+09 | 33554.49 | 01-MAY-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 80685632.72 | 4893.01 | 23-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.282465E+10 | 36346.02 | 30-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.775717E+10 | 36346.02 | 04-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.167389E+11 | 36346.02 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.715090E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.180803E+11 | 36346.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_5:5 HEATING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.184757E+11 | 36252.68 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.124687E+11 | 36252.68 | 01-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.104993E+11 | 36252.68 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.370696E+10 | 36252.68 | 02-APR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.222777E+09 | 36252.68 | 01-MAY-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 71494585.70 | 4957.40 | 23-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.293871E+10 | 36252.68 | 30-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.805783E+10 | 36252.68 | 04-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.171265E+11 | 36252.68 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.735678E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.184757E+11 | 36252.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_6:6 HEATING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.223513E+11 | 68858.05 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.124847E+11 | 68858.05 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.914012E+10 | 68858.05 | 01-MAR-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.220273E+10 | 68858.05 | 01-APR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 37497740.43 | 68858.05 | 01-MAY-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.135857E+10 | 68858.05 | 06-OCT-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.668221E+10 | 68858.05 | 01-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.195427E+11 | 68858.05 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.737998E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.223513E+11 | 68858.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_7:7 HEATING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.176792E+11 | 35179.30 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.118348E+11 | 35179.30 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.995216E+10 | 35179.30 | 01-MAR-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.349133E+10 | 35179.30 | 01-APR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.199953E+09 | 35179.30 | 01-MAY-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 88892478.37 | 3630.13 | 23-SEP-08:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.282002E+10 | 35179.30 | 06-OCT-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.769088E+10 | 35179.30 | 01-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.164016E+11 | 35179.30 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.701588E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.176792E+11 | 35179.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_8:8 HEATING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.177453E+11 | 35056.00 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.119167E+11 | 35056.00 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.100575E+11 | 35056.00 | 01-MAR-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.364951E+10 | 35056.00 | 01-APR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.248903E+09 | 35056.00 | 01-MAY-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.166320E+09 | 3995.01 | 29-SEP-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.299789E+10 | 35056.00 | 06-OCT-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.779498E+10 | 35056.00 | 01-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.164748E+11 | 35056.00 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.710520E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.177453E+11 | 35056.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_9:9 HEATING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.182937E+11 | 35048.53 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.123923E+11 | 35048.53 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.105966E+11 | 35048.53 | 01-MAR-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.406183E+10 | 35048.53 | 01-APR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.355988E+09 | 35048.53 | 01-MAY-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.260381E+09 | 10744.38 | 29-SEP-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.333520E+10 | 35048.53 | 04-OCT-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.823895E+10 | 35048.53 | 01-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.169966E+11 | 35048.53 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.745315E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.182937E+11 | 35048.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_10:10 HEATING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.235046E+11 | 39999.27 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.163091E+11 | 39999.27 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.139122E+11 | 39999.27 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.564534E+10 | 39999.27 | 01-APR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.691073E+09 | 39999.27 | 01-MAY-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 7107192.66 | 1170.85 | 03-JUN-08:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 587058.31 | 592.33 | 19-AUG-08:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.507618E+09 | 30192.00 | 28-SEP-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.442663E+10 | 39999.27 | 04-OCT-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.105158E+11 | 39999.27 | 01-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.217522E+11 | 39999.27 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.972722E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.235046E+11 | 39999.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_1:1 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.260341E+09 | 0.227791E+09 | 11315.79 | 23-APR-16:20 | 9916.60 | 0.00 |
May | 0.00 | 0.00 | 0.391283E+10 | 0.342298E+10 | 42509.29 | 26-MAY-08:62 | 28585.56 | 0.00 |
June | 0.00 | 0.00 | 0.964212E+10 | 0.722624E+10 | 45371.60 | 30-JUN-08:61 | 27614.17 | 0.00 |
July | 0.00 | 0.00 | 0.154848E+11 | 0.108760E+11 | 45361.80 | 23-JUL-07:02 | 21475.57 | 0.00 |
August | 0.00 | 0.00 | 0.112484E+11 | 0.792761E+10 | 44383.88 | 30-AUG-08:62 | 22651.96 | 0.00 |
September | 0.00 | 0.00 | 0.194798E+10 | 0.158527E+10 | 42947.39 | 01-SEP-08:62 | 22890.33 | 0.00 |
October | 0.00 | 0.00 | 0.190649E+09 | 0.178665E+09 | 5350.94 | 19-OCT-15:00 | 5146.23 | 0.00 |
November | 0.00 | 0.00 | 179875.21 | 145562.15 | 228.53 | 01-NOV-17:30 | 184.97 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.426873E+11 | 0.314447E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.154848E+11 | 0.108760E+11 | 45371.60 | 28585.56 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_2:2 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.176581E+09 | 0.156550E+09 | 21211.69 | 23-APR-18:42 | 19408.60 | 0.00 |
May | 0.00 | 0.00 | 0.265423E+10 | 0.233508E+10 | 22116.61 | 26-MAY-08:62 | 15463.18 | 0.00 |
June | 0.00 | 0.00 | 0.636690E+10 | 0.468735E+10 | 23343.95 | 30-JUN-08:61 | 15827.28 | 0.00 |
July | 0.00 | 0.00 | 0.998069E+10 | 0.688302E+10 | 23501.37 | 23-JUL-07:02 | 12083.18 | 0.00 |
August | 0.00 | 0.00 | 0.730178E+10 | 0.506408E+10 | 23305.01 | 31-AUG-20:03 | 12338.44 | 0.00 |
September | 0.00 | 0.00 | 0.128137E+10 | 0.103660E+10 | 22400.05 | 17-SEP-17:03 | 13089.38 | 0.00 |
October | 0.00 | 0.00 | 0.129655E+09 | 0.121217E+09 | 10102.32 | 22-OCT-17:02 | 8945.76 | 0.00 |
November | 0.00 | 0.00 | 338010.72 | 270765.84 | 563.35 | 01-NOV-20:40 | 451.28 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.278915E+11 | 0.202842E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.998069E+10 | 0.688302E+10 | 23501.37 | 19408.60 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_3:3 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 52846118.17 | 46778996.09 | 4884.97 | 23-APR-16:00 | 4423.94 | 0.00 |
May | 0.00 | 0.00 | 0.181036E+10 | 0.158784E+10 | 22001.35 | 26-MAY-07:02 | 15338.70 | 0.00 |
June | 0.00 | 0.00 | 0.456322E+10 | 0.341743E+10 | 23931.98 | 30-JUN-07:01 | 14043.25 | 0.00 |
July | 0.00 | 0.00 | 0.702062E+10 | 0.495120E+10 | 23770.02 | 23-JUL-08:61 | 12366.73 | 0.00 |
August | 0.00 | 0.00 | 0.510787E+10 | 0.359294E+10 | 22795.24 | 30-AUG-07:02 | 11358.11 | 0.00 |
September | 0.00 | 0.00 | 0.825787E+09 | 0.681524E+09 | 22208.55 | 01-SEP-07:02 | 11312.01 | 0.00 |
October | 0.00 | 0.00 | 66994319.03 | 63150758.30 | 2319.61 | 19-OCT-15:00 | 2243.58 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.194477E+11 | 0.143409E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.702062E+10 | 0.495120E+10 | 23931.98 | 15338.70 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_4:4 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 48528910.75 | 42960574.56 | 4669.94 | 23-APR-16:00 | 4230.33 | 0.00 |
May | 0.00 | 0.00 | 0.176913E+10 | 0.155094E+10 | 22058.17 | 26-MAY-07:02 | 15401.76 | 0.00 |
June | 0.00 | 0.00 | 0.452144E+10 | 0.338416E+10 | 23998.45 | 30-JUN-07:01 | 14132.23 | 0.00 |
July | 0.00 | 0.00 | 0.701939E+10 | 0.495370E+10 | 23832.44 | 23-JUL-08:61 | 12429.01 | 0.00 |
August | 0.00 | 0.00 | 0.507877E+10 | 0.357462E+10 | 22853.47 | 30-AUG-07:02 | 11395.00 | 0.00 |
September | 0.00 | 0.00 | 0.795640E+09 | 0.657219E+09 | 22265.98 | 01-SEP-07:02 | 11350.75 | 0.00 |
October | 0.00 | 0.00 | 56430983.33 | 53254841.37 | 2110.81 | 19-OCT-15:00 | 2044.58 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.192893E+11 | 0.142169E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.701939E+10 | 0.495370E+10 | 23998.45 | 15401.76 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_5:5 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 46872045.56 | 41420193.51 | 4572.81 | 23-APR-16:00 | 4134.73 | 0.00 |
May | 0.00 | 0.00 | 0.170878E+10 | 0.149600E+10 | 21984.68 | 26-MAY-07:02 | 15298.89 | 0.00 |
June | 0.00 | 0.00 | 0.440278E+10 | 0.328835E+10 | 23912.99 | 30-JUN-07:01 | 13973.96 | 0.00 |
July | 0.00 | 0.00 | 0.686505E+10 | 0.483533E+10 | 23755.41 | 23-JUL-08:61 | 12347.38 | 0.00 |
August | 0.00 | 0.00 | 0.493955E+10 | 0.347274E+10 | 22779.33 | 30-AUG-07:02 | 11317.96 | 0.00 |
September | 0.00 | 0.00 | 0.758986E+09 | 0.627152E+09 | 22193.94 | 01-SEP-07:02 | 11271.79 | 0.00 |
October | 0.00 | 0.00 | 50310899.07 | 47453654.22 | 1981.47 | 19-OCT-15:00 | 1915.96 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.187723E+11 | 0.138084E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.686505E+10 | 0.483533E+10 | 23912.99 | 15298.89 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_6:6 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 93618389.09 | 80576729.44 | 9020.51 | 23-APR-15:00 | 7690.46 | 0.00 |
May | 0.00 | 0.00 | 0.312817E+10 | 0.267551E+10 | 41331.02 | 26-MAY-08:62 | 28377.89 | 0.00 |
June | 0.00 | 0.00 | 0.753759E+10 | 0.568015E+10 | 44149.99 | 25-JUN-09:01 | 26066.06 | 0.00 |
July | 0.00 | 0.00 | 0.117094E+11 | 0.834853E+10 | 44508.95 | 23-JUL-09:01 | 26668.26 | 0.00 |
August | 0.00 | 0.00 | 0.893443E+10 | 0.627715E+10 | 43273.36 | 30-AUG-08:62 | 22144.90 | 0.00 |
September | 0.00 | 0.00 | 0.150907E+10 | 0.124473E+10 | 41896.88 | 01-SEP-08:62 | 22380.97 | 0.00 |
October | 0.00 | 0.00 | 0.124664E+09 | 0.117305E+09 | 4617.34 | 19-OCT-15:00 | 4393.28 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.330369E+11 | 0.244239E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.117094E+11 | 0.834853E+10 | 44508.95 | 28377.89 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_7:7 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 42960360.74 | 37342081.43 | 4560.66 | 23-APR-15:00 | 3963.20 | 0.00 |
May | 0.00 | 0.00 | 0.162506E+10 | 0.140638E+10 | 21376.56 | 26-MAY-08:62 | 14624.14 | 0.00 |
June | 0.00 | 0.00 | 0.421707E+10 | 0.311190E+10 | 22899.78 | 30-JUN-08:61 | 13831.81 | 0.00 |
July | 0.00 | 0.00 | 0.657634E+10 | 0.458976E+10 | 23038.40 | 23-JUL-09:01 | 13646.19 | 0.00 |
August | 0.00 | 0.00 | 0.479614E+10 | 0.332792E+10 | 22359.89 | 30-AUG-08:62 | 11465.23 | 0.00 |
September | 0.00 | 0.00 | 0.724866E+09 | 0.597312E+09 | 21666.55 | 01-SEP-08:62 | 11526.69 | 0.00 |
October | 0.00 | 0.00 | 49101567.62 | 46291080.41 | 2171.51 | 19-OCT-15:00 | 2074.24 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.180316E+11 | 0.131169E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.657634E+10 | 0.458976E+10 | 23038.40 | 14624.14 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_8:8 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 38631104.28 | 33495191.63 | 4241.08 | 23-APR-15:00 | 3673.25 | 0.00 |
May | 0.00 | 0.00 | 0.155260E+10 | 0.133979E+10 | 21291.74 | 26-MAY-08:62 | 14522.98 | 0.00 |
June | 0.00 | 0.00 | 0.411566E+10 | 0.302474E+10 | 22808.42 | 30-JUN-08:61 | 13715.89 | 0.00 |
July | 0.00 | 0.00 | 0.648217E+10 | 0.451441E+10 | 22945.79 | 23-JUL-09:01 | 13527.96 | 0.00 |
August | 0.00 | 0.00 | 0.470161E+10 | 0.325671E+10 | 22273.15 | 30-AUG-08:62 | 11390.60 | 0.00 |
September | 0.00 | 0.00 | 0.682397E+09 | 0.561048E+09 | 21582.33 | 01-SEP-08:62 | 11455.17 | 0.00 |
October | 0.00 | 0.00 | 40393345.03 | 38078653.95 | 1993.56 | 19-OCT-15:00 | 1900.54 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.176135E+11 | 0.127683E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.648217E+10 | 0.451441E+10 | 22945.79 | 14522.98 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_9:9 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 32402601.29 | 28035945.87 | 3751.22 | 23-APR-15:00 | 3238.27 | 0.00 |
May | 0.00 | 0.00 | 0.141635E+10 | 0.121929E+10 | 21231.94 | 26-MAY-08:62 | 14411.38 | 0.00 |
June | 0.00 | 0.00 | 0.390223E+10 | 0.285406E+10 | 22744.11 | 30-JUN-08:61 | 13577.43 | 0.00 |
July | 0.00 | 0.00 | 0.626389E+10 | 0.435392E+10 | 22878.48 | 23-JUL-09:01 | 13383.93 | 0.00 |
August | 0.00 | 0.00 | 0.448481E+10 | 0.310462E+10 | 22216.01 | 30-AUG-08:62 | 11298.80 | 0.00 |
September | 0.00 | 0.00 | 0.609259E+09 | 0.499069E+09 | 21527.00 | 01-SEP-08:62 | 11368.98 | 0.00 |
October | 0.00 | 0.00 | 28159858.98 | 26639548.82 | 1706.76 | 19-OCT-15:00 | 1625.56 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.167371E+11 | 0.120856E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.626389E+10 | 0.435392E+10 | 22878.48 | 14411.38 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_10:10 COOLING COIL
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 22715722.20 | 19707382.68 | 3009.41 | 23-APR-15:00 | 2598.31 | 0.00 |
May | 0.00 | 0.00 | 0.126266E+10 | 0.109353E+10 | 8893.36 | 25-MAY-15:00 | 7007.39 | 0.00 |
June | 0.00 | 0.00 | 0.376246E+10 | 0.276843E+10 | 27805.01 | 30-JUN-08:61 | 14864.90 | 0.00 |
July | 0.00 | 0.00 | 0.622603E+10 | 0.437987E+10 | 27654.01 | 23-JUL-09:01 | 16227.30 | 0.00 |
August | 0.00 | 0.00 | 0.423320E+10 | 0.298034E+10 | 26516.81 | 09-AUG-08:62 | 14889.46 | 0.00 |
September | 0.00 | 0.00 | 0.492704E+09 | 0.400842E+09 | 16395.05 | 01-SEP-08:62 | 8418.29 | 0.00 |
October | 0.00 | 0.00 | 8650782.19 | 8295430.61 | 1246.97 | 19-OCT-15:00 | 1200.30 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.160084E+11 | 0.116510E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.622603E+10 | 0.437987E+10 | 27805.01 | 16227.30 | 0.00 |
Report: FanReportMonthly
For: PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.212548E+10 | 0.50 | 2169.92 | 01-JAN-08:61 | 0.92 |
February | 0.172969E+10 | 0.45 | 2169.92 | 01-FEB-08:61 | 0.92 |
March | 0.179929E+10 | 0.42 | 2169.92 | 01-MAR-09:01 | 0.92 |
April | 0.157817E+10 | 0.39 | 2169.92 | 01-APR-08:61 | 0.92 |
May | 0.157565E+10 | 0.37 | 2169.92 | 01-MAY-08:61 | 0.92 |
June | 0.153997E+10 | 0.38 | 2169.92 | 22-JUN-08:62 | 0.90 |
July | 0.158016E+10 | 0.37 | 2169.92 | 01-JUL-08:62 | 0.91 |
August | 0.158066E+10 | 0.37 | 2169.92 | 08-AUG-08:62 | 0.90 |
September | 0.152817E+10 | 0.37 | 2169.92 | 01-SEP-08:62 | 0.90 |
October | 0.159653E+10 | 0.38 | 2169.92 | 06-OCT-08:61 | 0.92 |
November | 0.166632E+10 | 0.41 | 2169.92 | 03-NOV-08:61 | 0.92 |
December | 0.205939E+10 | 0.47 | 2169.92 | 01-DEC-08:61 | 0.92 |
Annual Sum or Average | 0.203595E+11 | 0.41 | |||
Minimum of Months | 0.152817E+10 | 0.37 | 2169.92 | 0.90 | |
Maximum of Months | 0.212548E+10 | 0.50 | 2169.92 | 0.92 |
Report: FanReportMonthly
For: PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.972390E+09 | 0.50 | 1185.94 | 01-JAN-08:61 | 0.95 |
February | 0.793375E+09 | 0.43 | 1185.94 | 01-FEB-08:61 | 0.95 |
March | 0.824162E+09 | 0.38 | 1185.94 | 01-MAR-09:01 | 0.95 |
April | 0.693646E+09 | 0.34 | 1185.94 | 02-APR-08:61 | 0.95 |
May | 0.776214E+09 | 0.38 | 1185.94 | 26-MAY-08:62 | 0.94 |
June | 0.790312E+09 | 0.38 | 1185.94 | 07-JUN-08:62 | 0.94 |
July | 0.805084E+09 | 0.38 | 1185.94 | 01-JUL-08:62 | 0.94 |
August | 0.803990E+09 | 0.38 | 1185.94 | 01-AUG-08:62 | 0.94 |
September | 0.767998E+09 | 0.38 | 1185.94 | 01-SEP-08:62 | 0.93 |
October | 0.715168E+09 | 0.34 | 1185.94 | 30-OCT-08:61 | 0.95 |
November | 0.750619E+09 | 0.35 | 1185.94 | 04-NOV-08:61 | 0.95 |
December | 0.943596E+09 | 0.48 | 1185.94 | 01-DEC-09:01 | 0.95 |
Annual Sum or Average | 0.963655E+10 | 0.39 | |||
Minimum of Months | 0.693646E+09 | 0.34 | 1185.94 | 0.93 | |
Maximum of Months | 0.972390E+09 | 0.50 | 1185.94 | 0.95 |
Report: FanReportMonthly
For: PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.103434E+10 | 0.40 | 1184.25 | 01-JAN-08:61 | 0.95 |
February | 0.854290E+09 | 0.38 | 1184.25 | 01-FEB-07:01 | 0.95 |
March | 0.894145E+09 | 0.37 | 1184.25 | 01-MAR-08:61 | 0.95 |
April | 0.731204E+09 | 0.33 | 1184.25 | 02-APR-08:61 | 0.95 |
May | 0.695926E+09 | 0.31 | 1184.25 | 26-MAY-07:02 | 0.94 |
June | 0.687495E+09 | 0.32 | 1184.25 | 19-JUN-07:02 | 0.93 |
July | 0.692267E+09 | 0.31 | 1184.25 | 01-JUL-07:02 | 0.94 |
August | 0.703059E+09 | 0.31 | 1184.25 | 01-AUG-07:02 | 0.94 |
September | 0.666271E+09 | 0.31 | 1184.25 | 01-SEP-07:02 | 0.93 |
October | 0.737216E+09 | 0.32 | 1184.25 | 30-OCT-07:01 | 0.95 |
November | 0.812739E+09 | 0.35 | 1184.25 | 05-NOV-08:61 | 0.95 |
December | 0.100511E+10 | 0.40 | 1184.25 | 01-DEC-08:61 | 0.95 |
Annual Sum or Average | 0.951407E+10 | 0.34 | |||
Minimum of Months | 0.666271E+09 | 0.31 | 1184.25 | 0.93 | |
Maximum of Months | 0.103434E+10 | 0.40 | 1184.25 | 0.95 |
Report: FanReportMonthly
For: PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.104323E+10 | 0.41 | 1188.06 | 01-JAN-08:61 | 0.95 |
February | 0.860703E+09 | 0.38 | 1188.06 | 01-FEB-07:01 | 0.95 |
March | 0.900676E+09 | 0.37 | 1188.06 | 01-MAR-08:61 | 0.95 |
April | 0.736521E+09 | 0.33 | 1188.06 | 02-APR-08:61 | 0.95 |
May | 0.698856E+09 | 0.31 | 1188.06 | 26-MAY-07:02 | 0.94 |
June | 0.689511E+09 | 0.32 | 1188.06 | 19-JUN-07:02 | 0.93 |
July | 0.694332E+09 | 0.31 | 1188.06 | 01-JUL-07:02 | 0.94 |
August | 0.705218E+09 | 0.31 | 1188.06 | 01-AUG-07:02 | 0.94 |
September | 0.669025E+09 | 0.31 | 1188.06 | 01-SEP-07:02 | 0.93 |
October | 0.743140E+09 | 0.33 | 1188.06 | 30-OCT-07:01 | 0.95 |
November | 0.819350E+09 | 0.35 | 1188.06 | 04-NOV-07:01 | 0.95 |
December | 0.101319E+10 | 0.40 | 1188.06 | 01-DEC-08:61 | 0.95 |
Annual Sum or Average | 0.957375E+10 | 0.34 | |||
Minimum of Months | 0.669025E+09 | 0.31 | 1188.06 | 0.93 | |
Maximum of Months | 0.104323E+10 | 0.41 | 1188.06 | 0.95 |
Report: FanReportMonthly
For: PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.104810E+10 | 0.42 | 1183.34 | 01-JAN-08:61 | 0.95 |
February | 0.864523E+09 | 0.38 | 1183.34 | 01-FEB-07:01 | 0.95 |
March | 0.904285E+09 | 0.37 | 1183.34 | 01-MAR-08:61 | 0.95 |
April | 0.737164E+09 | 0.33 | 1183.34 | 02-APR-08:61 | 0.95 |
May | 0.696418E+09 | 0.31 | 1183.34 | 01-MAY-07:02 | 0.95 |
June | 0.686243E+09 | 0.32 | 1183.34 | 19-JUN-07:02 | 0.93 |
July | 0.690883E+09 | 0.31 | 1183.34 | 01-JUL-07:02 | 0.94 |
August | 0.702126E+09 | 0.31 | 1183.34 | 01-AUG-07:02 | 0.94 |
September | 0.666163E+09 | 0.31 | 1183.34 | 01-SEP-07:02 | 0.93 |
October | 0.742566E+09 | 0.33 | 1183.34 | 30-OCT-07:01 | 0.95 |
November | 0.822375E+09 | 0.36 | 1183.34 | 04-NOV-07:01 | 0.95 |
December | 0.101795E+10 | 0.41 | 1183.34 | 01-DEC-08:61 | 0.95 |
Annual Sum or Average | 0.957880E+10 | 0.35 | |||
Minimum of Months | 0.666163E+09 | 0.31 | 1183.34 | 0.93 | |
Maximum of Months | 0.104810E+10 | 0.42 | 1183.34 | 0.95 |
Report: FanReportMonthly
For: PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.154430E+10 | 0.38 | 2109.25 | 01-JAN-09:01 | 0.92 |
February | 0.125112E+10 | 0.32 | 2109.25 | 01-FEB-08:61 | 0.92 |
March | 0.131946E+10 | 0.31 | 2109.25 | 01-MAR-09:01 | 0.92 |
April | 0.113392E+10 | 0.28 | 2109.25 | 01-APR-08:61 | 0.92 |
May | 0.114003E+10 | 0.28 | 2109.25 | 01-MAY-08:61 | 0.92 |
June | 0.112125E+10 | 0.28 | 2109.25 | 19-JUN-08:62 | 0.90 |
July | 0.112845E+10 | 0.27 | 2109.25 | 01-JUL-08:62 | 0.91 |
August | 0.115465E+10 | 0.28 | 2109.25 | 01-AUG-08:62 | 0.91 |
September | 0.109370E+10 | 0.28 | 2109.25 | 01-SEP-08:62 | 0.90 |
October | 0.115181E+10 | 0.28 | 2109.25 | 06-OCT-08:61 | 0.92 |
November | 0.121625E+10 | 0.30 | 2109.25 | 01-NOV-08:61 | 0.92 |
December | 0.148437E+10 | 0.35 | 2109.25 | 01-DEC-08:61 | 0.92 |
Annual Sum or Average | 0.147393E+11 | 0.30 | |||
Minimum of Months | 0.109370E+10 | 0.27 | 2109.25 | 0.90 | |
Maximum of Months | 0.154430E+10 | 0.38 | 2109.25 | 0.92 |
Report: FanReportMonthly
For: PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.949136E+09 | 0.41 | 1132.07 | 01-JAN-09:01 | 0.95 |
February | 0.776659E+09 | 0.36 | 1132.07 | 01-FEB-08:61 | 0.95 |
March | 0.810154E+09 | 0.35 | 1132.07 | 01-MAR-09:01 | 0.95 |
April | 0.654273E+09 | 0.31 | 1132.07 | 01-APR-08:61 | 0.95 |
May | 0.615314E+09 | 0.29 | 1132.07 | 01-MAY-08:61 | 0.95 |
June | 0.609650E+09 | 0.29 | 1132.07 | 22-JUN-08:62 | 0.93 |
July | 0.613761E+09 | 0.28 | 1132.07 | 01-JUL-08:62 | 0.94 |
August | 0.621711E+09 | 0.29 | 1132.07 | 01-AUG-08:62 | 0.94 |
September | 0.588705E+09 | 0.29 | 1132.07 | 01-SEP-08:62 | 0.93 |
October | 0.659244E+09 | 0.30 | 1132.07 | 06-OCT-08:61 | 0.95 |
November | 0.735358E+09 | 0.33 | 1132.07 | 01-NOV-08:61 | 0.95 |
December | 0.920325E+09 | 0.39 | 1132.07 | 01-DEC-08:61 | 0.95 |
Annual Sum or Average | 0.855429E+10 | 0.32 | |||
Minimum of Months | 0.588705E+09 | 0.28 | 1132.07 | 0.93 | |
Maximum of Months | 0.949136E+09 | 0.41 | 1132.07 | 0.95 |
Report: FanReportMonthly
For: PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.946773E+09 | 0.41 | 1126.24 | 01-JAN-09:01 | 0.95 |
February | 0.775122E+09 | 0.36 | 1126.24 | 01-FEB-08:61 | 0.95 |
March | 0.808703E+09 | 0.35 | 1126.24 | 01-MAR-09:01 | 0.95 |
April | 0.654191E+09 | 0.31 | 1126.24 | 01-APR-08:61 | 0.95 |
May | 0.613079E+09 | 0.29 | 1126.24 | 01-MAY-08:61 | 0.95 |
June | 0.606268E+09 | 0.29 | 1126.24 | 22-JUN-08:62 | 0.93 |
July | 0.610282E+09 | 0.28 | 1126.24 | 01-JUL-08:62 | 0.94 |
August | 0.618338E+09 | 0.29 | 1126.24 | 01-AUG-08:62 | 0.94 |
September | 0.587167E+09 | 0.29 | 1126.24 | 01-SEP-08:62 | 0.93 |
October | 0.659470E+09 | 0.30 | 1126.24 | 06-OCT-08:61 | 0.95 |
November | 0.734099E+09 | 0.33 | 1126.24 | 01-NOV-08:61 | 0.95 |
December | 0.918225E+09 | 0.40 | 1126.24 | 01-DEC-08:61 | 0.95 |
Annual Sum or Average | 0.853172E+10 | 0.33 | |||
Minimum of Months | 0.587167E+09 | 0.28 | 1126.24 | 0.93 | |
Maximum of Months | 0.946773E+09 | 0.41 | 1126.24 | 0.95 |
Report: FanReportMonthly
For: PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.955711E+09 | 0.43 | 1122.49 | 01-JAN-09:01 | 0.95 |
February | 0.782439E+09 | 0.38 | 1122.49 | 01-FEB-08:61 | 0.95 |
March | 0.816652E+09 | 0.36 | 1122.49 | 01-MAR-09:01 | 0.95 |
April | 0.659952E+09 | 0.31 | 1122.49 | 01-APR-08:61 | 0.95 |
May | 0.613067E+09 | 0.29 | 1122.49 | 01-MAY-08:61 | 0.95 |
June | 0.603360E+09 | 0.29 | 1122.49 | 25-JUN-09:01 | 0.93 |
July | 0.607017E+09 | 0.28 | 1122.49 | 01-JUL-08:62 | 0.94 |
August | 0.615758E+09 | 0.29 | 1122.49 | 08-AUG-08:62 | 0.93 |
September | 0.586994E+09 | 0.29 | 1122.49 | 01-SEP-08:62 | 0.93 |
October | 0.663769E+09 | 0.30 | 1122.49 | 04-OCT-08:61 | 0.95 |
November | 0.740220E+09 | 0.33 | 1122.49 | 01-NOV-08:61 | 0.95 |
December | 0.926206E+09 | 0.41 | 1122.49 | 01-DEC-08:61 | 0.95 |
Annual Sum or Average | 0.857115E+10 | 0.33 | |||
Minimum of Months | 0.586994E+09 | 0.28 | 1122.49 | 0.93 | |
Maximum of Months | 0.955711E+09 | 0.43 | 1122.49 | 0.95 |
Report: FanReportMonthly
For: PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.125148E+10 | 0.59 | 1372.63 | 01-JAN-08:61 | 0.95 |
February | 0.102167E+10 | 0.54 | 1372.63 | 01-FEB-08:61 | 0.95 |
March | 0.104698E+10 | 0.45 | 1372.63 | 01-MAR-08:61 | 0.95 |
April | 0.829158E+09 | 0.33 | 1372.63 | 01-APR-08:61 | 0.95 |
May | 0.755449E+09 | 0.29 | 1372.63 | 01-MAY-07:02 | 0.95 |
June | 0.730014E+09 | 0.29 | 1372.63 | 25-JUN-09:01 | 0.93 |
July | 0.732183E+09 | 0.28 | 1372.63 | 04-JUL-09:02 | 0.93 |
August | 0.749701E+09 | 0.29 | 1372.63 | 09-AUG-08:62 | 0.93 |
September | 0.722049E+09 | 0.29 | 1170.70 | 28-SEP-08:62 | 0.88 |
October | 0.824485E+09 | 0.31 | 1372.63 | 04-OCT-08:61 | 0.95 |
November | 0.932302E+09 | 0.38 | 1372.63 | 01-NOV-08:61 | 0.95 |
December | 0.120601E+10 | 0.56 | 1372.63 | 01-DEC-08:61 | 0.95 |
Annual Sum or Average | 0.108015E+11 | 0.38 | |||
Minimum of Months | 0.722049E+09 | 0.28 | 1170.70 | 0.88 | |
Maximum of Months | 0.125148E+10 | 0.59 | 1372.63 | 0.95 |
Report: ZoneTemperatureOscillationReportMonthly
For: LGSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: LGSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE8
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_1:1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.212548E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.172969E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.179929E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.164792E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.261025E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.400302E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.544477E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.438333E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.203391E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.164868E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.166637E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.205939E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.311521E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.164792E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.544477E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_2:2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.972390E+09 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.793375E+09 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.824162E+09 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.737826E+09 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.143643E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.232793E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.316085E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.253054E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.108582E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.749283E+09 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.750713E+09 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.943596E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.163129E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.737826E+09 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.316085E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_3:3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.103434E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.854290E+09 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.894145E+09 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.745312E+09 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.116188E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.181166E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.238339E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.193949E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.875861E+09 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.755350E+09 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.812739E+09 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.100511E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.142736E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.745312E+09 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.238339E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_4:4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.104323E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.860703E+09 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.900676E+09 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.749557E+09 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.115497E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.180395E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.238583E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.193574E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.870904E+09 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.758486E+09 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.819350E+09 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.101319E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.142966E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.749557E+09 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.238583E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_5:5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.104810E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.864523E+09 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.904285E+09 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.749784E+09 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.113812E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.177308E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.234784E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.190113E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.858899E+09 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.756285E+09 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.822375E+09 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.101795E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.141824E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.749784E+09 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.234784E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_6:6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.154430E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.125112E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.131946E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.115949E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.197033E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.305275E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.405557E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.338468E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.148500E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.118611E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.121625E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.148437E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.231094E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.115949E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.405557E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_7:7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.949136E+09 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.776659E+09 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.810154E+09 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.665839E+09 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.103563E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.164961E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.219725E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.178358E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.772349E+09 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.672584E+09 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.735358E+09 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.920325E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.129685E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.665839E+09 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.219725E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_8:8
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.946773E+09 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.775122E+09 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.808703E+09 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.664676E+09 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.101575E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.162186E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.217221E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.175843E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.759893E+09 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.670495E+09 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.734099E+09 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.918225E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.128462E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.664676E+09 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.217221E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_9:9
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.955711E+09 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.782439E+09 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.816652E+09 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.668859E+09 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.982866E+09 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.156868E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.211990E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.170647E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.741124E+09 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.671515E+09 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.740220E+09 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.926206E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.126806E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.668859E+09 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.211990E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_10:10
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.125148E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.102167E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.104698E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.835615E+09 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.109411E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.168126E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.226954E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.180296E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.847688E+09 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.826914E+09 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.932302E+09 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.120601E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.148165E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.826914E+09 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.226954E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_1:1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.212548E+10 | 0.00 | 0.289907E+11 | 0.167050E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.172969E+10 | 0.00 | 0.161205E+11 | 0.155496E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.179929E+10 | 0.00 | 0.115427E+11 | 0.154293E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.157817E+10 | 0.260341E+09 | 0.281610E+10 | 0.916409E+10 | 11711152.62 | 0.00 | 0.00 | 0.00 |
May | 0.157565E+10 | 0.391283E+10 | 31410602.30 | 0.293656E+10 | 0.215368E+09 | 0.00 | 0.00 | 0.00 |
June | 0.153997E+10 | 0.964212E+10 | 0.00 | 0.744519E+09 | 0.123553E+10 | 0.00 | 0.00 | 0.00 |
July | 0.158016E+10 | 0.154848E+11 | 0.00 | 0.185841E+09 | 0.192118E+10 | 0.00 | 0.00 | 0.00 |
August | 0.158066E+10 | 0.112484E+11 | 0.00 | 0.390142E+09 | 0.737349E+09 | 0.00 | 0.00 | 0.00 |
September | 0.152817E+10 | 0.194798E+10 | 0.00 | 0.277889E+10 | 30291016.41 | 0.00 | 0.00 | 0.00 |
October | 0.159653E+10 | 0.190649E+09 | 0.115941E+10 | 0.904034E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.166632E+10 | 179875.21 | 0.767248E+10 | 0.131124E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.205939E+10 | 0.00 | 0.253160E+11 | 0.175250E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.203595E+11 | 0.426873E+11 | 0.936493E+11 | 0.103562E+12 | 0.415142E+10 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.152817E+10 | 0.00 | 0.00 | 0.185841E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.212548E+10 | 0.154848E+11 | 0.289907E+11 | 0.175250E+11 | 0.192118E+10 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_2:2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.972390E+09 | 0.00 | 0.163496E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.793375E+09 | 0.00 | 0.106065E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.824162E+09 | 0.00 | 0.860381E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.693646E+09 | 0.162662E+09 | 0.257481E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.776214E+09 | 0.252557E+10 | 52817405.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.790312E+09 | 0.612533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.805084E+09 | 0.951932E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.803990E+09 | 0.693187E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.767998E+09 | 0.123357E+10 | 1269310.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.715168E+09 | 0.129655E+09 | 0.179280E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.750619E+09 | 338010.72 | 0.636868E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.943596E+09 | 0.00 | 0.151288E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.963655E+10 | 0.266283E+11 | 0.614792E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.693646E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.972390E+09 | 0.951932E+10 | 0.163496E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_3:3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.103434E+10 | 0.00 | 0.177869E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.854290E+09 | 0.00 | 0.119220E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.894145E+09 | 0.00 | 0.995217E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.731204E+09 | 52846118.17 | 0.337568E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.695926E+09 | 0.181036E+10 | 0.165351E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.687495E+09 | 0.456322E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.692267E+09 | 0.702062E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.703059E+09 | 0.510787E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.666271E+09 | 0.825787E+09 | 49278966.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.737216E+09 | 66994319.03 | 0.263795E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.812739E+09 | 0.00 | 0.753771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.100511E+10 | 0.00 | 0.164734E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.951407E+10 | 0.194477E+11 | 0.699004E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.666271E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.103434E+10 | 0.702062E+10 | 0.177869E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_4:4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.104323E+10 | 0.00 | 0.180803E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.860703E+09 | 0.00 | 0.121325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.900676E+09 | 0.00 | 0.101593E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.736521E+09 | 48528910.75 | 0.353392E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.698856E+09 | 0.176913E+10 | 0.201652E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.689511E+09 | 0.452144E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.694332E+09 | 0.701939E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.705218E+09 | 0.507877E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.669025E+09 | 0.795640E+09 | 80685632.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.743140E+09 | 56430983.33 | 0.282465E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.819350E+09 | 0.00 | 0.775717E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.101319E+10 | 0.00 | 0.167389E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.957375E+10 | 0.192893E+11 | 0.715090E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.669025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.104323E+10 | 0.701939E+10 | 0.180803E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_5:5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.104810E+10 | 0.00 | 0.184757E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.864523E+09 | 0.00 | 0.124687E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.904285E+09 | 0.00 | 0.104993E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.737164E+09 | 46872045.56 | 0.370696E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.696418E+09 | 0.170878E+10 | 0.222777E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.686243E+09 | 0.440278E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.690883E+09 | 0.686505E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.702126E+09 | 0.493955E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.666163E+09 | 0.758986E+09 | 71494585.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.742566E+09 | 50310899.07 | 0.293871E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.822375E+09 | 0.00 | 0.805783E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.101795E+10 | 0.00 | 0.171265E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.957880E+10 | 0.187723E+11 | 0.735678E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.666163E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.104810E+10 | 0.686505E+10 | 0.184757E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_6:6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.154430E+10 | 0.00 | 0.223513E+11 | 0.127306E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.125112E+10 | 0.00 | 0.124847E+11 | 0.111996E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.131946E+10 | 0.00 | 0.914012E+10 | 0.110764E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.113392E+10 | 93618389.09 | 0.220273E+10 | 0.639165E+10 | 4138138.70 | 0.00 | 0.00 | 0.00 |
May | 0.114003E+10 | 0.312817E+10 | 37497740.43 | 0.234885E+10 | 0.175362E+09 | 0.00 | 0.00 | 0.00 |
June | 0.112125E+10 | 0.753759E+10 | 0.00 | 0.560566E+09 | 0.102320E+10 | 0.00 | 0.00 | 0.00 |
July | 0.112845E+10 | 0.117094E+11 | 0.00 | 0.141771E+09 | 0.154993E+10 | 0.00 | 0.00 | 0.00 |
August | 0.115465E+10 | 0.893443E+10 | 0.00 | 0.317241E+09 | 0.670728E+09 | 0.00 | 0.00 | 0.00 |
September | 0.109370E+10 | 0.150907E+10 | 0.00 | 0.232750E+10 | 25656360.69 | 0.00 | 0.00 | 0.00 |
October | 0.115181E+10 | 0.124664E+09 | 0.135857E+10 | 0.640146E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.121625E+10 | 0.00 | 0.668221E+10 | 0.913024E+10 | 1947.28 | 0.00 | 0.00 | 0.00 |
December | 0.148437E+10 | 0.00 | 0.195427E+11 | 0.130646E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.147393E+11 | 0.330369E+11 | 0.737998E+11 | 0.756905E+11 | 0.344902E+10 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.109370E+10 | 0.00 | 0.00 | 0.141771E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.154430E+10 | 0.117094E+11 | 0.223513E+11 | 0.130646E+11 | 0.154993E+10 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_7:7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.949136E+09 | 0.00 | 0.176792E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.776659E+09 | 0.00 | 0.118348E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.810154E+09 | 0.00 | 0.995216E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.654273E+09 | 42960360.74 | 0.349133E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.615314E+09 | 0.162506E+10 | 0.199953E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.609650E+09 | 0.421707E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.613761E+09 | 0.657634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.621711E+09 | 0.479614E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.588705E+09 | 0.724866E+09 | 88892478.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.659244E+09 | 49101567.62 | 0.282002E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.735358E+09 | 0.00 | 0.769088E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.920325E+09 | 0.00 | 0.164016E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.855429E+10 | 0.180316E+11 | 0.701588E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.588705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.949136E+09 | 0.657634E+10 | 0.176792E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_8:8
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.946773E+09 | 0.00 | 0.177453E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.775122E+09 | 0.00 | 0.119167E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.808703E+09 | 0.00 | 0.100575E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.654191E+09 | 38631104.28 | 0.364951E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.613079E+09 | 0.155260E+10 | 0.248903E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.606268E+09 | 0.411566E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.610282E+09 | 0.648217E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.618338E+09 | 0.470161E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.587167E+09 | 0.682397E+09 | 0.166320E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.659470E+09 | 40393345.03 | 0.299789E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.734099E+09 | 0.00 | 0.779498E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.918225E+09 | 0.00 | 0.164748E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.853172E+10 | 0.176135E+11 | 0.710520E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.587167E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.946773E+09 | 0.648217E+10 | 0.177453E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_9:9
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.955711E+09 | 0.00 | 0.182937E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.782439E+09 | 0.00 | 0.123923E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.816652E+09 | 0.00 | 0.105966E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.659952E+09 | 32402601.29 | 0.406183E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.613067E+09 | 0.141635E+10 | 0.355988E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.603360E+09 | 0.390223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.607017E+09 | 0.626389E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.615758E+09 | 0.448481E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.586994E+09 | 0.609259E+09 | 0.260381E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.663769E+09 | 28159858.98 | 0.333520E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.740220E+09 | 0.00 | 0.823895E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.926206E+09 | 0.00 | 0.169966E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.857115E+10 | 0.167371E+11 | 0.745315E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.586994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.955711E+09 | 0.626389E+10 | 0.182937E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_10:10
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.125148E+10 | 0.00 | 0.235046E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.102167E+10 | 0.00 | 0.163091E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.104698E+10 | 0.00 | 0.139122E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.829158E+09 | 22715722.20 | 0.564534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.755449E+09 | 0.126266E+10 | 0.691073E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.730014E+09 | 0.376246E+10 | 7107192.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.732183E+09 | 0.622603E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.749701E+09 | 0.423320E+10 | 587058.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.722049E+09 | 0.492704E+09 | 0.507618E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.824485E+09 | 8650782.19 | 0.442663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.932302E+09 | 0.00 | 0.105158E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.120601E+10 | 0.00 | 0.217522E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.108015E+11 | 0.160084E+11 | 0.972722E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.722049E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.125148E+10 | 0.622603E+10 | 0.235046E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_1:1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.212548E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.172969E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.179929E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.157817E+10 | 0.00 | 0.00 | 0.00 | 69749941.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.157565E+10 | 0.00 | 0.00 | 0.00 | 0.103460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.153997E+10 | 0.00 | 0.00 | 0.00 | 0.246305E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.158016E+10 | 0.00 | 0.00 | 0.00 | 0.386461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.158066E+10 | 0.00 | 0.00 | 0.00 | 0.280267E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.152817E+10 | 0.00 | 0.00 | 0.00 | 0.505740E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.159653E+10 | 0.00 | 0.00 | 0.00 | 52152291.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.166632E+10 | 0.00 | 0.00 | 0.00 | 51879.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.205939E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.203595E+11 | 0.00 | 0.00 | 0.00 | 0.107926E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.152817E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.212548E+10 | 0.00 | 0.00 | 0.00 | 0.386461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_2:2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.972390E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.793375E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.824162E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.693646E+09 | 0.00 | 0.00 | 0.00 | 44179568.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.776214E+09 | 0.00 | 0.00 | 0.00 | 0.660218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.790312E+09 | 0.00 | 0.00 | 0.00 | 0.153762E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.805084E+09 | 0.00 | 0.00 | 0.00 | 0.235576E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.803990E+09 | 0.00 | 0.00 | 0.00 | 0.172655E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.767998E+09 | 0.00 | 0.00 | 0.00 | 0.317826E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.715168E+09 | 0.00 | 0.00 | 0.00 | 34114642.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.750619E+09 | 0.00 | 0.00 | 0.00 | 94439.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.943596E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.963655E+10 | 0.00 | 0.00 | 0.00 | 0.667636E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.693646E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.972390E+09 | 0.00 | 0.00 | 0.00 | 0.235576E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_3:3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.103434E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.854290E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.894145E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.731204E+09 | 0.00 | 0.00 | 0.00 | 14107766.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.695926E+09 | 0.00 | 0.00 | 0.00 | 0.465950E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.687495E+09 | 0.00 | 0.00 | 0.00 | 0.112417E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.692267E+09 | 0.00 | 0.00 | 0.00 | 0.169113E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.703059E+09 | 0.00 | 0.00 | 0.00 | 0.123643E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.666271E+09 | 0.00 | 0.00 | 0.00 | 0.209590E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.737216E+09 | 0.00 | 0.00 | 0.00 | 18134197.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.812739E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.100511E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.951407E+10 | 0.00 | 0.00 | 0.00 | 0.475951E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.666271E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.103434E+10 | 0.00 | 0.00 | 0.00 | 0.169113E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_4:4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.104323E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.860703E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.900676E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.736521E+09 | 0.00 | 0.00 | 0.00 | 13035367.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.698856E+09 | 0.00 | 0.00 | 0.00 | 0.456112E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.689511E+09 | 0.00 | 0.00 | 0.00 | 0.111444E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.694332E+09 | 0.00 | 0.00 | 0.00 | 0.169150E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.705218E+09 | 0.00 | 0.00 | 0.00 | 0.123052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.669025E+09 | 0.00 | 0.00 | 0.00 | 0.201880E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.743140E+09 | 0.00 | 0.00 | 0.00 | 15345643.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.819350E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.101319E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.957375E+10 | 0.00 | 0.00 | 0.00 | 0.472284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.669025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.104323E+10 | 0.00 | 0.00 | 0.00 | 0.169150E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_5:5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.104810E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.864523E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.904285E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.737164E+09 | 0.00 | 0.00 | 0.00 | 12619842.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.696418E+09 | 0.00 | 0.00 | 0.00 | 0.441701E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.686243E+09 | 0.00 | 0.00 | 0.00 | 0.108684E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.690883E+09 | 0.00 | 0.00 | 0.00 | 0.165696E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.702126E+09 | 0.00 | 0.00 | 0.00 | 0.119900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.666163E+09 | 0.00 | 0.00 | 0.00 | 0.192735E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.742566E+09 | 0.00 | 0.00 | 0.00 | 13718642.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.822375E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.101795E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.957880E+10 | 0.00 | 0.00 | 0.00 | 0.460358E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.666163E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.104810E+10 | 0.00 | 0.00 | 0.00 | 0.165696E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_6:6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.154430E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.125112E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.131946E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.113392E+10 | 0.00 | 0.00 | 0.00 | 25569584.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.114003E+10 | 0.00 | 0.00 | 0.00 | 0.830302E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.112125E+10 | 0.00 | 0.00 | 0.00 | 0.193150E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.112845E+10 | 0.00 | 0.00 | 0.00 | 0.292712E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.115465E+10 | 0.00 | 0.00 | 0.00 | 0.223003E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.109370E+10 | 0.00 | 0.00 | 0.00 | 0.391302E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.115181E+10 | 0.00 | 0.00 | 0.00 | 34290787.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.121625E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.148437E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.147393E+11 | 0.00 | 0.00 | 0.00 | 0.837012E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.109370E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.154430E+10 | 0.00 | 0.00 | 0.00 | 0.292712E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_7:7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.949136E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.776659E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.810154E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.654273E+09 | 0.00 | 0.00 | 0.00 | 11565429.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.615314E+09 | 0.00 | 0.00 | 0.00 | 0.420314E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.609650E+09 | 0.00 | 0.00 | 0.00 | 0.103996E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.613761E+09 | 0.00 | 0.00 | 0.00 | 0.158349E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.621711E+09 | 0.00 | 0.00 | 0.00 | 0.116187E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.588705E+09 | 0.00 | 0.00 | 0.00 | 0.183644E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.659244E+09 | 0.00 | 0.00 | 0.00 | 13340186.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.735358E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.920325E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.855429E+10 | 0.00 | 0.00 | 0.00 | 0.441419E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.588705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.949136E+09 | 0.00 | 0.00 | 0.00 | 0.158349E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_8:8
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.946773E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.775122E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.808703E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.654191E+09 | 0.00 | 0.00 | 0.00 | 10485569.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.613079E+09 | 0.00 | 0.00 | 0.00 | 0.402672E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.606268E+09 | 0.00 | 0.00 | 0.00 | 0.101559E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.610282E+09 | 0.00 | 0.00 | 0.00 | 0.156192E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.618338E+09 | 0.00 | 0.00 | 0.00 | 0.114009E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.587167E+09 | 0.00 | 0.00 | 0.00 | 0.172726E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.659470E+09 | 0.00 | 0.00 | 0.00 | 11025173.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.734099E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.918225E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.853172E+10 | 0.00 | 0.00 | 0.00 | 0.431452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.587167E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.946773E+09 | 0.00 | 0.00 | 0.00 | 0.156192E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_9:9
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.955711E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.782439E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.816652E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.659952E+09 | 0.00 | 0.00 | 0.00 | 8906563.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.613067E+09 | 0.00 | 0.00 | 0.00 | 0.369799E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.603360E+09 | 0.00 | 0.00 | 0.00 | 0.965325E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.607017E+09 | 0.00 | 0.00 | 0.00 | 0.151288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.615758E+09 | 0.00 | 0.00 | 0.00 | 0.109071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.586994E+09 | 0.00 | 0.00 | 0.00 | 0.154131E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.663769E+09 | 0.00 | 0.00 | 0.00 | 7745122.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.740220E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.926206E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.857115E+10 | 0.00 | 0.00 | 0.00 | 0.410950E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.586994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.955711E+09 | 0.00 | 0.00 | 0.00 | 0.151288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_10:10
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.125148E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.102167E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.104698E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.829158E+09 | 0.00 | 0.00 | 0.00 | 6457491.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.755449E+09 | 0.00 | 0.00 | 0.00 | 0.338656E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.730014E+09 | 0.00 | 0.00 | 0.00 | 0.951244E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.732183E+09 | 0.00 | 0.00 | 0.00 | 0.153736E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.749701E+09 | 0.00 | 0.00 | 0.00 | 0.105326E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.722049E+09 | 0.00 | 0.00 | 0.00 | 0.125639E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.824485E+09 | 0.00 | 0.00 | 0.00 | 2429314.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.932302E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.120601E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.108015E+11 | 0.00 | 0.00 | 0.00 | 0.401504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.722049E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.125148E+10 | 0.00 | 0.00 | 0.00 | 0.153736E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: LGSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.459080E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142170E+11 | 0.00 | 0.00 | 0.52 |
February | 0.779234E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.755089E+10 | 0.00 | 0.00 | 0.53 |
March | 0.145516E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.539280E+10 | 0.00 | 0.00 | 0.53 |
April | 0.231747E+10 | 4280634.30 | 0.00 | 1622876.00 | 231988.76 | 0.143341E+10 | 0.123567E+10 | 0.00 | 0.55 |
May | 0.713342E+09 | 0.117340E+09 | 0.00 | 11296239.78 | 145427.00 | 23380872.18 | 0.499899E+10 | 0.00 | 0.73 |
June | 82005051.14 | 0.105937E+10 | 0.00 | 13346878.46 | 3191122.03 | 0.00 | 0.463782E+10 | 0.00 | 0.87 |
July | 13715532.05 | 0.188099E+10 | 0.00 | 14303908.17 | 9603288.94 | 0.00 | 0.351659E+10 | 0.00 | 0.89 |
August | 60684884.12 | 0.979072E+09 | 0.00 | 18624609.44 | 1191816.37 | 0.00 | 0.509380E+10 | 0.00 | 0.96 |
September | 0.591116E+09 | 37248964.40 | 0.00 | 13066580.27 | 0.00 | 0.00 | 0.746934E+10 | 0.00 | 0.77 |
October | 0.287655E+10 | 0.00 | 0.00 | 2942591.39 | 0.00 | 0.730205E+09 | 0.217140E+10 | 0.00 | 0.57 |
November | 0.206371E+10 | 0.00 | 106657.59 | 5572.05 | 177948.52 | 0.376066E+10 | 14271863.63 | 23385.18 | 0.53 |
December | 0.303084E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120819E+11 | 0.00 | 0.00 | 0.52 |
Annual Sum or Average | 0.117152E+11 | 0.407830E+10 | 106657.59 | 75209255.56 | 14541591.62 | 0.451903E+11 | 0.291379E+11 | 23385.18 | 0.66 |
Minimum of Months | 13715532.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.52 |
Maximum of Months | 0.287655E+10 | 0.188099E+10 | 106657.59 | 18624609.44 | 9603288.94 | 0.142170E+11 | 0.746934E+10 | 23385.18 | 0.96 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE1
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.472069E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109418E+11 | 0.00 | 0.00 | 0.39 |
February | 0.115278E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.724101E+10 | 0.00 | 0.00 | 0.39 |
March | 0.239533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.547236E+10 | 0.00 | 0.00 | 0.39 |
April | 0.275417E+10 | 6771899.62 | 0.00 | 682628.83 | 0.00 | 0.154855E+10 | 0.518364E+09 | 0.00 | 0.43 |
May | 0.135632E+10 | 0.162984E+09 | 0.00 | 4945788.27 | 314765.48 | 11184964.00 | 0.228016E+10 | 0.00 | 0.69 |
June | 0.292843E+09 | 0.102995E+10 | 0.00 | 6091460.33 | 3708640.17 | 0.00 | 0.219101E+10 | 0.00 | 0.83 |
July | 48565872.65 | 0.177899E+10 | 0.00 | 5588706.87 | 9454996.67 | 0.00 | 0.154486E+10 | 0.00 | 0.80 |
August | 0.107648E+09 | 0.830602E+09 | 0.00 | 8143110.69 | 2339482.32 | 0.00 | 0.232564E+10 | 0.00 | 0.91 |
September | 0.125856E+10 | 31879305.91 | 0.00 | 6503751.63 | 0.00 | 0.00 | 0.364373E+10 | 0.00 | 0.76 |
October | 0.355331E+10 | 0.00 | 0.00 | 1269297.97 | 0.00 | 0.751132E+09 | 0.879687E+09 | 0.00 | 0.46 |
November | 0.243515E+10 | 0.00 | 0.00 | 4088.46 | 0.00 | 0.409094E+10 | 2794016.03 | 0.00 | 0.39 |
December | 0.556329E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101270E+11 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | 0.163831E+11 | 0.384117E+10 | 0.00 | 33228833.04 | 15817884.64 | 0.401840E+11 | 0.133862E+11 | 0.00 | 0.57 |
Minimum of Months | 48565872.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 |
Maximum of Months | 0.355331E+10 | 0.177899E+10 | 0.00 | 8143110.69 | 9454996.67 | 0.109418E+11 | 0.364373E+10 | 0.00 | 0.91 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 74678191.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119417E+11 | 0.00 | 0.00 | 0.41 |
February | 0.545988E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.839660E+10 | 0.00 | 0.00 | 0.41 |
March | 0.142362E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.696679E+10 | 0.00 | 0.00 | 0.42 |
April | 0.267122E+10 | 4432549.91 | 0.00 | 172276.23 | 1233184.90 | 0.201553E+10 | 0.168693E+09 | 0.00 | 0.43 |
May | 0.174403E+10 | 0.153042E+09 | 0.00 | 1987118.96 | 1791652.11 | 45040960.61 | 0.953270E+09 | 0.00 | 0.56 |
June | 0.556052E+09 | 0.833383E+09 | 0.00 | 3595944.94 | 41631600.47 | 0.00 | 0.121467E+10 | 0.00 | 0.69 |
July | 0.144031E+09 | 0.131016E+10 | 0.00 | 3953123.87 | 84720499.53 | 0.00 | 0.988250E+09 | 0.00 | 0.67 |
August | 0.290746E+09 | 0.689814E+09 | 0.00 | 5018165.35 | 17990912.82 | 0.00 | 0.156509E+10 | 0.00 | 0.75 |
September | 0.177649E+10 | 32598565.39 | 0.00 | 3215021.72 | 0.00 | 0.00 | 0.188869E+10 | 0.00 | 0.62 |
October | 0.333695E+10 | 0.00 | 0.00 | 456885.78 | 0.00 | 0.129042E+10 | 0.325841E+09 | 0.00 | 0.45 |
November | 0.177949E+10 | 0.00 | 50938.96 | 0.00 | 21590.40 | 0.506876E+10 | 0.00 | 5420.38 | 0.41 |
December | 87007016.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111391E+11 | 0.00 | 0.00 | 0.41 |
Annual Sum or Average | 0.144303E+11 | 0.302343E+10 | 50938.96 | 18398536.85 | 0.147389E+09 | 0.468640E+11 | 0.710451E+10 | 5420.38 | 0.52 |
Minimum of Months | 74678191.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.333695E+10 | 0.131016E+10 | 50938.96 | 5018165.35 | 84720499.53 | 0.119417E+11 | 0.188869E+10 | 5420.38 | 0.75 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE3
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 47044315.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119693E+11 | 0.00 | 0.00 | 0.41 |
February | 0.434833E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.850771E+10 | 0.00 | 0.00 | 0.41 |
March | 0.125573E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.713445E+10 | 0.00 | 0.00 | 0.42 |
April | 0.254749E+10 | 4288357.26 | 0.00 | 131900.13 | 1258279.13 | 0.215627E+10 | 0.130866E+09 | 0.00 | 0.42 |
May | 0.177027E+10 | 0.151525E+09 | 0.00 | 1881134.79 | 1771542.46 | 58528147.32 | 0.881022E+09 | 0.00 | 0.56 |
June | 0.564929E+09 | 0.832268E+09 | 0.00 | 3501791.81 | 39979222.01 | 0.00 | 0.118993E+10 | 0.00 | 0.69 |
July | 0.149459E+09 | 0.130865E+10 | 0.00 | 3975551.76 | 84201046.53 | 0.00 | 0.985251E+09 | 0.00 | 0.67 |
August | 0.293427E+09 | 0.686003E+09 | 0.00 | 5002595.84 | 17849729.15 | 0.00 | 0.156852E+10 | 0.00 | 0.76 |
September | 0.182248E+10 | 32411770.60 | 0.00 | 3082801.49 | 0.00 | 4773698.44 | 0.181034E+10 | 0.00 | 0.61 |
October | 0.310841E+10 | 0.00 | 0.00 | 409686.63 | 0.00 | 0.153331E+10 | 0.292411E+09 | 0.00 | 0.44 |
November | 0.166101E+10 | 0.00 | 59418.29 | 0.00 | 22622.96 | 0.518587E+10 | 0.00 | 7781.88 | 0.41 |
December | 82160498.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111439E+11 | 0.00 | 0.00 | 0.41 |
Annual Sum or Average | 0.137372E+11 | 0.301515E+10 | 59418.29 | 17985462.46 | 0.145082E+09 | 0.476941E+11 | 0.685834E+10 | 7781.88 | 0.52 |
Minimum of Months | 47044315.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.310841E+10 | 0.130865E+10 | 59418.29 | 5002595.84 | 84201046.53 | 0.119693E+11 | 0.181034E+10 | 7781.88 | 0.76 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE4
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 33781789.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119826E+11 | 0.00 | 0.00 | 0.41 |
February | 0.315343E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.862721E+10 | 0.00 | 0.00 | 0.41 |
March | 0.104644E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.734363E+10 | 0.00 | 0.00 | 0.42 |
April | 0.236116E+10 | 4257213.42 | 0.00 | 112327.86 | 1284755.52 | 0.235409E+10 | 0.108720E+09 | 0.00 | 0.42 |
May | 0.177369E+10 | 0.149997E+09 | 0.00 | 1750513.08 | 1776793.49 | 70965214.61 | 0.836245E+09 | 0.00 | 0.56 |
June | 0.574755E+09 | 0.822151E+09 | 0.00 | 3319489.96 | 41068469.45 | 0.00 | 0.115557E+10 | 0.00 | 0.68 |
July | 0.171534E+09 | 0.129213E+10 | 0.00 | 3801829.95 | 85619421.00 | 0.00 | 0.959219E+09 | 0.00 | 0.66 |
August | 0.306993E+09 | 0.674494E+09 | 0.00 | 4756357.77 | 17741791.64 | 0.00 | 0.153898E+10 | 0.00 | 0.75 |
September | 0.185173E+10 | 31948975.82 | 0.00 | 2932444.31 | 0.00 | 4774956.85 | 0.175005E+10 | 0.00 | 0.61 |
October | 0.299143E+10 | 0.00 | 0.00 | 384695.34 | 0.00 | 0.165845E+10 | 0.277218E+09 | 0.00 | 0.44 |
November | 0.141046E+10 | 0.00 | 67707.36 | 0.00 | 23674.13 | 0.543500E+10 | 0.00 | 10089.77 | 0.41 |
December | 55293275.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111707E+11 | 0.00 | 0.00 | 0.41 |
Annual Sum or Average | 0.128926E+11 | 0.297498E+10 | 67707.36 | 17057658.29 | 0.147515E+09 | 0.486474E+11 | 0.662600E+10 | 10089.77 | 0.52 |
Minimum of Months | 33781789.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.299143E+10 | 0.129213E+10 | 67707.36 | 4756357.77 | 85619421.00 | 0.119826E+11 | 0.175005E+10 | 10089.77 | 0.75 |
Report: MechanicalVentilationLoadsMonthly
For: LGSTORE2
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 28719455.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.981260E+10 | 0.00 | 0.00 | 0.38 |
February | 0.128961E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.553317E+10 | 0.00 | 0.00 | 0.38 |
March | 0.508476E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.442919E+10 | 0.00 | 0.00 | 0.39 |
April | 0.146365E+10 | 1460080.41 | 0.00 | 468822.74 | 4305315.39 | 0.132278E+10 | 0.524084E+09 | 0.00 | 0.39 |
May | 0.731993E+09 | 86525480.45 | 0.00 | 4412161.83 | 252835.75 | 25199689.83 | 0.245250E+10 | 0.00 | 0.51 |
June | 83706347.02 | 0.733790E+09 | 0.00 | 6512215.52 | 25002622.91 | 0.00 | 0.276169E+10 | 0.00 | 0.61 |
July | 22450817.98 | 0.121034E+10 | 0.00 | 6582072.39 | 91549876.42 | 0.00 | 0.188466E+10 | 0.00 | 0.59 |
August | 46492058.51 | 0.721113E+09 | 0.00 | 8463832.32 | 5187750.52 | 0.00 | 0.294813E+10 | 0.00 | 0.67 |
September | 0.739380E+09 | 29948793.85 | 0.00 | 6587578.10 | 0.00 | 0.00 | 0.427528E+10 | 0.00 | 0.55 |
October | 0.183459E+10 | 0.00 | 0.00 | 1061087.06 | 0.00 | 0.949113E+09 | 0.869722E+09 | 0.00 | 0.41 |
November | 0.684741E+09 | 0.00 | 728634.21 | 0.00 | 1258158.13 | 0.340223E+10 | 0.00 | 52207.56 | 0.38 |
December | 38540305.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.808822E+10 | 0.00 | 0.00 | 0.37 |
Annual Sum or Average | 0.631170E+10 | 0.278318E+10 | 728634.21 | 34087769.96 | 0.127557E+09 | 0.335625E+11 | 0.157161E+11 | 52207.56 | 0.47 |
Minimum of Months | 22450817.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.37 |
Maximum of Months | 0.183459E+10 | 0.121034E+10 | 728634.21 | 8463832.32 | 91549876.42 | 0.981260E+10 | 0.427528E+10 | 52207.56 | 0.67 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE5
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 8725939.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110583E+11 | 0.00 | 0.00 | 0.38 |
February | 0.141269E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.806734E+10 | 0.00 | 0.00 | 0.38 |
March | 0.652996E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.706397E+10 | 0.00 | 0.00 | 0.39 |
April | 0.206921E+10 | 2523419.72 | 0.00 | 70008.19 | 1277603.70 | 0.228832E+10 | 81683446.89 | 0.00 | 0.39 |
May | 0.159907E+10 | 0.121795E+09 | 0.00 | 1568268.91 | 126672.60 | 51976846.70 | 0.788135E+09 | 0.00 | 0.51 |
June | 0.465739E+09 | 0.782161E+09 | 0.00 | 2906336.28 | 13765953.88 | 0.00 | 0.114383E+10 | 0.00 | 0.62 |
July | 0.137154E+09 | 0.121668E+10 | 0.00 | 3228880.85 | 45064293.06 | 0.00 | 0.902537E+09 | 0.00 | 0.60 |
August | 0.269247E+09 | 0.622783E+09 | 0.00 | 4066262.47 | 3100427.60 | 0.00 | 0.138860E+10 | 0.00 | 0.68 |
September | 0.167221E+10 | 25059320.02 | 0.00 | 2609025.99 | 0.00 | 1566486.37 | 0.166811E+10 | 0.00 | 0.55 |
October | 0.260871E+10 | 0.00 | 0.00 | 327917.59 | 0.00 | 0.169847E+10 | 0.261345E+09 | 0.00 | 0.40 |
November | 0.911627E+09 | 0.00 | 5022.85 | 0.00 | 19826.13 | 0.543196E+10 | 0.00 | 36851.21 | 0.38 |
December | 12594073.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103499E+11 | 0.00 | 0.00 | 0.37 |
Annual Sum or Average | 0.105485E+11 | 0.277100E+10 | 5022.85 | 14776700.29 | 63354776.97 | 0.460118E+11 | 0.623425E+10 | 36851.21 | 0.47 |
Minimum of Months | 8725939.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.37 |
Maximum of Months | 0.260871E+10 | 0.121668E+10 | 5022.85 | 4066262.47 | 45064293.06 | 0.110583E+11 | 0.166811E+10 | 36851.21 | 0.68 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE6
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 8722439.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110583E+11 | 0.00 | 0.00 | 0.38 |
February | 0.121956E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.808666E+10 | 0.00 | 0.00 | 0.38 |
March | 0.588615E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.712834E+10 | 0.00 | 0.00 | 0.39 |
April | 0.195196E+10 | 2381576.59 | 0.00 | 48914.78 | 1470868.67 | 0.241410E+10 | 54269831.21 | 0.00 | 0.38 |
May | 0.161501E+10 | 0.120102E+09 | 0.00 | 1433895.44 | 129105.99 | 59901067.05 | 0.710634E+09 | 0.00 | 0.50 |
June | 0.494527E+09 | 0.776900E+09 | 0.00 | 2701116.31 | 14765776.78 | 0.00 | 0.107608E+10 | 0.00 | 0.61 |
July | 0.145658E+09 | 0.120860E+10 | 0.00 | 3135844.90 | 45024512.84 | 0.00 | 0.887860E+09 | 0.00 | 0.60 |
August | 0.300820E+09 | 0.615798E+09 | 0.00 | 3931148.52 | 3067560.15 | 0.00 | 0.134420E+10 | 0.00 | 0.68 |
September | 0.171413E+10 | 24870737.13 | 0.00 | 2419161.83 | 0.00 | 3793892.36 | 0.156410E+10 | 0.00 | 0.54 |
October | 0.248808E+10 | 0.00 | 0.00 | 287922.44 | 0.00 | 0.181880E+10 | 0.240021E+09 | 0.00 | 0.40 |
November | 0.853109E+09 | 0.00 | 3998.73 | 0.00 | 26127.59 | 0.548975E+10 | 0.00 | 41898.43 | 0.38 |
December | 11962462.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103505E+11 | 0.00 | 0.00 | 0.37 |
Annual Sum or Average | 0.102946E+11 | 0.274865E+10 | 3998.73 | 13958004.22 | 64483952.02 | 0.464102E+11 | 0.587717E+10 | 41898.43 | 0.47 |
Minimum of Months | 8722439.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.37 |
Maximum of Months | 0.248808E+10 | 0.120860E+10 | 3998.73 | 3931148.52 | 45024512.84 | 0.110583E+11 | 0.156410E+10 | 41898.43 | 0.68 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE7
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 6744153.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110602E+11 | 0.00 | 0.00 | 0.38 |
February | 41607086.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.816696E+10 | 0.00 | 0.00 | 0.38 |
March | 0.397215E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.731965E+10 | 0.00 | 0.00 | 0.39 |
April | 0.156270E+10 | 2148826.01 | 82723.18 | 22828.20 | 1568254.78 | 0.280287E+10 | 30605478.61 | 564.11 | 0.38 |
May | 0.157884E+10 | 0.115213E+09 | 0.00 | 1173635.88 | 298801.65 | 0.100443E+09 | 0.624656E+09 | 0.00 | 0.48 |
June | 0.558058E+09 | 0.761097E+09 | 0.00 | 2342486.16 | 15123012.41 | 0.00 | 0.953966E+09 | 0.00 | 0.59 |
July | 0.155146E+09 | 0.118445E+10 | 0.00 | 2911556.91 | 43241381.31 | 0.00 | 0.873206E+09 | 0.00 | 0.59 |
August | 0.341641E+09 | 0.597378E+09 | 0.00 | 3620186.80 | 2955426.80 | 0.00 | 0.127910E+10 | 0.00 | 0.67 |
September | 0.177799E+10 | 24220469.79 | 0.00 | 2108747.87 | 0.00 | 28290491.40 | 0.138002E+10 | 0.00 | 0.53 |
October | 0.213186E+10 | 0.00 | 0.00 | 236365.56 | 0.00 | 0.218085E+10 | 0.210218E+09 | 0.00 | 0.40 |
November | 0.589162E+09 | 0.00 | 9230.71 | 0.00 | 39516.64 | 0.575205E+10 | 0.00 | 57550.37 | 0.38 |
December | 8911183.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103535E+11 | 0.00 | 0.00 | 0.37 |
Annual Sum or Average | 0.914987E+10 | 0.268451E+10 | 91953.89 | 12415807.37 | 63226393.60 | 0.477648E+11 | 0.535177E+10 | 58114.49 | 0.46 |
Minimum of Months | 6744153.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.37 |
Maximum of Months | 0.213186E+10 | 0.118445E+10 | 82723.18 | 3620186.80 | 43241381.31 | 0.110602E+11 | 0.138002E+10 | 57550.37 | 0.67 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE8
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 4080221.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110449E+11 | 0.00 | 0.00 | 0.38 |
February | 6731433.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.818081E+10 | 0.00 | 0.00 | 0.38 |
March | 32636059.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.766158E+10 | 0.00 | 0.00 | 0.39 |
April | 0.820358E+09 | 1835468.82 | 191188.80 | 1660.66 | 1427369.72 | 0.352701E+10 | 561922.34 | 19197.87 | 0.38 |
May | 0.132001E+10 | 0.108713E+09 | 0.00 | 795158.48 | 4210.30 | 0.394948E+09 | 0.494497E+09 | 0.00 | 0.49 |
June | 0.605822E+09 | 0.741289E+09 | 0.00 | 2053030.94 | 12888169.33 | 0.00 | 0.911953E+09 | 0.00 | 0.64 |
July | 0.159926E+09 | 0.116958E+10 | 0.00 | 2756934.94 | 40304213.27 | 0.00 | 0.101810E+10 | 0.00 | 0.65 |
August | 0.413336E+09 | 0.579787E+09 | 0.00 | 3188371.48 | 2584694.25 | 0.00 | 0.134131E+10 | 0.00 | 0.74 |
September | 0.165213E+10 | 25196012.86 | 0.00 | 1754563.95 | 0.00 | 0.170392E+09 | 0.130528E+10 | 0.00 | 0.54 |
October | 0.122991E+10 | 0.00 | 0.00 | 181822.33 | 0.00 | 0.306022E+10 | 0.196540E+09 | 0.00 | 0.40 |
November | 96089805.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.622980E+10 | 0.00 | 20602.10 | 0.38 |
December | 6517503.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103367E+11 | 0.00 | 0.00 | 0.37 |
Annual Sum or Average | 0.634753E+10 | 0.262640E+10 | 191188.80 | 10731542.78 | 57208656.87 | 0.506063E+11 | 0.526824E+10 | 39799.97 | 0.48 |
Minimum of Months | 4080221.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.37 |
Maximum of Months | 0.165213E+10 | 0.116958E+10 | 191188.80 | 3188371.48 | 40304213.27 | 0.110449E+11 | 0.134131E+10 | 20602.10 | 0.74 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 08:41:09
Custom Monthly ReportSITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
January | 0.118085E+12 | 0.686157E+11 | 0.00 | 0.146778E+12 | 0.498143E+11 |
February | 0.203434E+12 | 0.504648E+11 | 0.00 | 0.110686E+12 | 0.320469E+11 |
March | 0.309512E+12 | 0.444514E+11 | 0.00 | 0.104820E+12 | 0.261040E+11 |
April | 0.413321E+12 | 0.271348E+11 | 0.00 | 0.625846E+11 | 0.979672E+10 |
May | 0.497753E+12 | 0.119196E+11 | 0.00 | 0.338640E+11 | 0.268123E+11 |
June | 0.512154E+12 | 0.240611E+10 | 0.00 | 0.120204E+11 | 0.662630E+11 |
July | 0.524671E+12 | -0.312505E+10 | 0.00 | -0.254793E+10 | 0.104011E+12 |
August | 0.432896E+12 | 0.235201E+10 | 0.00 | 0.151194E+11 | 0.756978E+11 |
September | 0.310572E+12 | 0.146021E+11 | 0.00 | 0.467280E+11 | 0.123898E+11 |
October | 0.167307E+12 | 0.256611E+11 | 0.00 | 0.646550E+11 | 0.752026E+10 |
November | 0.697478E+11 | 0.391924E+11 | 0.00 | 0.872948E+11 | 0.195798E+11 |
December | 0.716725E+11 | 0.665939E+11 | 0.00 | 0.138160E+12 | 0.454878E+11 |
Annual Sum or Average | 0.363113E+13 | 0.350269E+12 | 0.00 | 0.820162E+12 | 0.475524E+12 |
Minimum of Months | 0.697478E+11 | -0.312505E+10 | 0.00 | -0.254793E+10 | 0.752026E+10 |
Maximum of Months | 0.524671E+12 | 0.686157E+11 | 0.00 | 0.146778E+12 | 0.104011E+12 |