Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 10:43
Tabular Output Report in Format: HTML
Building: Warehouse
Environment: RUNPERIOD 1 ** Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000
Simulation Timestamp: 2023-10-16 10:43:49
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 610.17 | 126.20 | 126.20 |
Net Site Energy | 610.17 | 126.20 | 126.20 |
Total Source Energy | 1932.41 | 399.66 | 399.66 |
Net Source Energy | 1932.41 | 399.66 | 399.66 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 1.200 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil No 1 | 1.050 |
Fuel Oil No 2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4835.13 |
Net Conditioned Building Area | 4835.13 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 159.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 139.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 92.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 139.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 56.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 22.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 610.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 159.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 139.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 92.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 139.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 29.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 26.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 22.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | Unassigned | 159.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GENERAL | 139.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | Unassigned | 92.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | GENERAL | 139.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Unassigned | 56.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Unassigned | 22.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 48.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 49.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 126.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 48.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 49.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 126.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 610.170 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 610.170 | 100.00 |
Total On-Site and Utility Electric Sources | 610.170 | 100.00 |
Total Electricity End Uses | 610.170 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 51.61 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 51.61 | 100.00 |
Total Water End Uses | 51.61 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 25.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 3636.00 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 0A
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY VNM_HOCHIMINH_TANSONHOA
| Environment |ZoneCoolingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneHeatingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneElectricSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |PeakSpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainComponentsAtCoolingPeakMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ComfortReportSimple55Monthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |OccupantComfortDataSummaryMonthly
| OFFICE PEOPLE | ZONE2 FINE STORAGEPEOPLE | ZONE3 BULK STORAGEPEOPLE |DXReportMonthly
| PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |WindowReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | FINESTORAGE_SKYLIGHT_1 | FINESTORAGE_SKYLIGHT_6 | FINESTORAGE_SKYLIGHT_7 | FINESTORAGE_SKYLIGHT_8 | FINESTORAGE_SKYLIGHT_9 | FINESTORAGE_SKYLIGHT_10 | FINESTORAGE_SKYLIGHT_5 | FINESTORAGE_SKYLIGHT_4 | FINESTORAGE_SKYLIGHT_3 | FINESTORAGE_SKYLIGHT_2 | FINESTORAGE_SKYLIGHT_14 | FINESTORAGE_SKYLIGHT_13 | FINESTORAGE_SKYLIGHT_12 | FINESTORAGE_SKYLIGHT_11 | SKYLIGHT_R8C1 | SKYLIGHT_R8C2 | SKYLIGHT_R8C4 | SKYLIGHT_R1C2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C4 | SKYLIGHT_R1C3 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R3C4 | SKYLIGHT_R3C2 | SKYLIGHT_R3C3 | SKYLIGHT_R3C1 | SKYLIGHT_R4C4 | SKYLIGHT_R4C3 | SKYLIGHT_R4C2 | SKYLIGHT_R4C1 | SKYLIGHT_R5C4 | SKYLIGHT_R5C1 | SKYLIGHT_R5C3 | SKYLIGHT_R5C2 | SKYLIGHT_R6C1 | SKYLIGHT_R6C2 | SKYLIGHT_R8C3 | SKYLIGHT_R6C4 | SKYLIGHT_R7C1 | SKYLIGHT_R7C2 | SKYLIGHT_R7C4 | SKYLIGHT_R6C3 | SKYLIGHT_R7C3 |WindowEnergyReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | FINESTORAGE_SKYLIGHT_1 | FINESTORAGE_SKYLIGHT_6 | FINESTORAGE_SKYLIGHT_7 | FINESTORAGE_SKYLIGHT_8 | FINESTORAGE_SKYLIGHT_9 | FINESTORAGE_SKYLIGHT_10 | FINESTORAGE_SKYLIGHT_5 | FINESTORAGE_SKYLIGHT_4 | FINESTORAGE_SKYLIGHT_3 | FINESTORAGE_SKYLIGHT_2 | FINESTORAGE_SKYLIGHT_14 | FINESTORAGE_SKYLIGHT_13 | FINESTORAGE_SKYLIGHT_12 | FINESTORAGE_SKYLIGHT_11 | SKYLIGHT_R8C1 | SKYLIGHT_R8C2 | SKYLIGHT_R8C4 | SKYLIGHT_R1C2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C4 | SKYLIGHT_R1C3 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R3C4 | SKYLIGHT_R3C2 | SKYLIGHT_R3C3 | SKYLIGHT_R3C1 | SKYLIGHT_R4C4 | SKYLIGHT_R4C3 | SKYLIGHT_R4C2 | SKYLIGHT_R4C1 | SKYLIGHT_R5C4 | SKYLIGHT_R5C1 | SKYLIGHT_R5C3 | SKYLIGHT_R5C2 | SKYLIGHT_R6C1 | SKYLIGHT_R6C2 | SKYLIGHT_R8C3 | SKYLIGHT_R6C4 | SKYLIGHT_R7C1 | SKYLIGHT_R7C2 | SKYLIGHT_R7C4 | SKYLIGHT_R6C3 | SKYLIGHT_R7C3 |WindowZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |WindowEnergyZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWHSYS1 WATER HEATER |DaylightingReportMonthly
| ZONE2 FINE STORAGE_DAYLCTRL | ZONE3 BULK STORAGE_DAYLCTRL | ZONE1 OFFICE_DAYLCTRL |CoilReportMonthly
| PSZ-OFFICE HEATING COIL | PSZ-FINE STORAGE HEATING COIL | ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |FanReportMonthly
| ZONE3UNITHEATER ZONE3HIRADIANT FAN | PSZ-OFFICE_ADDAQ SUPPLY FAN | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN |ZoneTemperatureOscillationReportMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentLoadsMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentEnergyUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |MechanicalVentilationLoadsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
GeneralValue | |
Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 10:43 |
RunPeriod | RUNPERIOD 1 |
Weather File | Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 |
Latitude [deg] | 10.82 |
Longitude [deg] | 106.67 |
Elevation [m] | 5.00 |
Time Zone | 7.00 |
North Axis Angle [deg] | 90.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | |
Gross Roof Area [m2] | 4598.25 |
Skylight Area [m2] | 68.38 |
Skylight-Roof Ratio [%] | 1.49 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
ZONE1 OFFICE | 236.88 | Yes | Yes | 1010.76 | 1.00 | 149.56 | 0.00 | 17.66 | 17.66 | 8.9961 | 18.58 | 8.0737 |
ZONE2 FINE STORAGE | 1393.41 | Yes | Yes | 2953.02 | 1.00 | 760.80 | 0.00 | 0.00 | 0.00 | 9.2031 | 46.45 | 0.0000 |
ZONE3 BULK STORAGE | 3204.84 | Yes | Yes | 35277.63 | 1.00 | 1586.63 | 0.00 | 0.00 | 0.00 | 5.6188 | 46.45 | 2.5587 |
Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 6.8172 | 43.27 | 2.0915 | |||
Conditioned Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 6.8172 | 43.27 | 2.0915 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
ZONE1 OFFICE | 236.88 | Yes | Yes | 1.00 | ZONE1 OFFICE | GENERAL | ZONE1 OFFICE | 8.9961 | 18.58 | 8.0737 | |
ZONE2 FINE STORAGE | 1393.41 | Yes | Yes | 1.00 | ZONE2 FINE STORAGE | GENERAL | ZONE2 FINE STORAGE | 9.2031 | 46.45 | 0.0000 | |
ZONE3 BULK STORAGE | 3204.84 | Yes | Yes | 1.00 | ZONE3 BULK STORAGE | GENERAL | ZONE3 BULK STORAGE | 5.6188 | 46.45 | 2.5587 | |
Total | 4835.13 | 6.8172 | 21.63 | 2.0915 | |||||||
Conditioned Total | 4835.13 | 6.8172 | 21.63 | 2.0915 | |||||||
Unconditioned Total | 0.00 | 0.0000 | 0.00 | 0.0000 | |||||||
Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
GENERAL | 4835.13 | 4835.13 | 0.00 | 0.00 | 6.8172 | 43.27 | 2.0915 |
Total | 4835.13 | 4835.13 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
End UsesElectricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 06-MAY-15:09 | - | - | - | - | - | - | - | - | - | - | - | 02-JAN-12:09 |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 19529.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 7834.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 5268.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1414.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 44160.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 19529.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 7834.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 2963.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 1414.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 505.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 442.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 293.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 441.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 179.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 70.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1932.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 104.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 91.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 60.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 91.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 37.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 14.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 399.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 104.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 91.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 60.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 91.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 37.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 14.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 399.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
AirTerminal:SingleDuct:ConstantVolume:NoReheatDesign Size Maximum Air Flow Rate [m3/s] | |
ZONE1 OFFICE DIRECT AIR | 1.16 |
ZONE2 FINE STORAGE DIRECT AIR | 2.76 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
ZONE3 BULK STORAGE UNIT HEATER | 0.976836 |
Design Size Maximum Flow Rate [m3/s] | |
ZONE3UNITHEATER ZONE3HIRADIANT FAN | 0.976836 |
Design Size Nominal Capacity [W] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | 39959.00 |
PSZ-OFFICE HEATING COIL | 26733.89 |
PSZ-FINE STORAGE HEATING COIL | 123059.84 |
User-Specified Heating Design Capacity [W] | |
ZONE3 BULK STORAGE HIRADIANT | 0.000000 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-OFFICE | 1.16 | 1.16 | 1.16 | 1.16 | 1.16 | 1.16 | 1.00 | 1.00 | 1.16 |
PSZ-FINE STORAGE | 2.76 | 2.76 | 2.76 | 2.76 | 2.76 | 2.76 | 1.00 | 1.00 | 2.76 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-OFFICE_OA_CONTROLLER | 1.16 | 0.102285 |
PSZ-FINE STORAGE_OA_CONTROLLER | 2.76 | 0.424711 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-OFFICE_ADDAQ SUPPLY FAN | 1.16 | 1289.00 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | 2.76 | 2950.28 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-OFFICE_UNITARY_PACKAGE_DX | 1.16 | 1.16 | 1.16 | 0.768402 | 24617.40 | 26733.89 | 40.00 | 1.00 |
PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | 2.76 | 2.76 | 2.76 | 1.82 | 68466.54 | 123059.84 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | User-Specified Speed 2 Rated Sensible Heat Ratio | User-Specified Speed 1 Rated Sensible Heat Ratio | |
PSZ-OFFICE COOLING COIL | 1.16 | 0.582123 | 0.776167 | 24617.40 | 12308.70 | 0.754830 | 0.754830 |
PSZ-FINE STORAGE COOLING COIL | 2.76 | 1.38 | 1.84 | 68466.54 | 34233.27 | 0.701080 | 0.701080 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
OFFICE FRONT WALL | OFFICE FRONT DOOR | OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | |
OFFICE LEFT WALL | OFFICE LEFT WALL DOOR | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | |
FINE STORAGE FRONT WALL | FINE STORAGE OVERHEAD DOOR1 | |
FINE STORAGE RIGHT WALL | FINE STORAGE OVERHEAD DOOR2 | FINE STORAGE OVERHEAD DOOR3 | FINE STORAGE RIGHT DOOR | |
FINE STORAGE LEFT WALL | FINE STORAGE OVERHEAD DOOR4 | FINE STORAGE LEFT DOOR | |
FINE STORAGE ROOF | FINESTORAGE_SKYLIGHT_1 | FINESTORAGE_SKYLIGHT_6 | FINESTORAGE_SKYLIGHT_7 | FINESTORAGE_SKYLIGHT_8 | FINESTORAGE_SKYLIGHT_9 | FINESTORAGE_SKYLIGHT_10 | FINESTORAGE_SKYLIGHT_5 | FINESTORAGE_SKYLIGHT_4 | FINESTORAGE_SKYLIGHT_3 | FINESTORAGE_SKYLIGHT_2 | FINESTORAGE_SKYLIGHT_14 | FINESTORAGE_SKYLIGHT_13 | FINESTORAGE_SKYLIGHT_12 | FINESTORAGE_SKYLIGHT_11 | |
BULK STORAGE RIGHT WALL | BULK STORAGE OVERHEAD DOOR8 | BULK STORAGE OVERHEAD DOOR9 | BULK STORAGE OVERHEAD DOOR10 | BULK STORAGE OVERHEAD DOOR11 | BULK STORAGE DOOR1 | BULK STORAGE DOOR2 | BULK STORAGE DOOR3 | |
BULK STORAGE REAR WALL | BULK STORAGE OVERHEAD DOOR12 | BULK STORAGE OVERHEAD DOOR13 | BULK STORAGE OVERHEAD DOOR14 | BULK STORAGE OVERHEAD DOOR15 | BULK STORAGE DOOR4 | |
BULK STORAGE LEFT WALL | BULK STORAGE OVERHEAD DOOR1 | BULK STORAGE OVERHEAD DOOR2 | BULK STORAGE OVERHEAD DOOR3 | BULK STORAGE OVERHEAD DOOR4 | BULK STORAGE OVERHEAD DOOR5 | BULK STORAGE OVERHEAD DOOR6 | BULK STORAGE OVERHEAD DOOR7 | BULK STORAGE DOOR5 | |
BULK STORAGE ROOF | SKYLIGHT_R8C1 | SKYLIGHT_R8C2 | SKYLIGHT_R8C4 | SKYLIGHT_R1C2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C4 | SKYLIGHT_R1C3 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R3C4 | SKYLIGHT_R3C2 | SKYLIGHT_R3C3 | SKYLIGHT_R3C1 | SKYLIGHT_R4C4 | SKYLIGHT_R4C3 | SKYLIGHT_R4C2 | SKYLIGHT_R4C1 | SKYLIGHT_R5C4 | SKYLIGHT_R5C1 | SKYLIGHT_R5C3 | SKYLIGHT_R5C2 | SKYLIGHT_R6C1 | SKYLIGHT_R6C2 | SKYLIGHT_R8C3 | SKYLIGHT_R6C4 | SKYLIGHT_R7C1 | SKYLIGHT_R7C2 | SKYLIGHT_R7C4 | SKYLIGHT_R6C3 | SKYLIGHT_R7C3 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
VersionVersion ID | |
1 | 22.1 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 26.90 | 26.70 | 26.00 | 26.40 | 27.50 | 28.30 | 29.20 | 29.00 | 28.90 | 27.20 | 27.50 | 27.60 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 | 10.82 | 106.67 | 7.00 | 5.00 | 101265 | 1.2036 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 27.60 | 3.20 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | Warehouse | 90.000 | Urban | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.220 | 370.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 3 | 102 | 78 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | ZONE1 OFFICE | 0.0 | 0.00 | 0.00 | 0.00 | 4.57 | -12.95 | 2.13 | 1 | 1 | 1 | 0.00 | 9.14 | -25.91 | 5.60E-016 | 0.00 | 4.27 | 4.27 | 1010.76 | TARP | TARP | 236.88 | 149.56 | 128.00 | 17.66 | 6 | 6 | 0 | Yes |
2 | ZONE2 FINE STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 14.29 | -22.82 | 4.51 | 1 | 1 | 1 | 0.00 | 30.48 | -45.72 | 1.87E-015 | 0.00 | 8.53 | 7.81 | 2953.02 | TARP | TARP | 1393.41 | 760.80 | 727.17 | 20.81 | 11 | 20 | 0 | Yes |
3 | ZONE3 BULK STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 65.53 | -22.86 | 4.27 | 1 | 1 | 1 | 30.48 | 100.58 | -45.72 | 6.16E-015 | 0.00 | 8.53 | 8.53 | 35277.63 | TARP | TARP | 3204.84 | 1586.63 | 1471.35 | 47.57 | 6 | 52 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | ZONE1 OFFICE | 236.88 | 12.7 | 18.581 | 5.382E-002 | 8.996 | 8.074 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | No |
2 | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 46.447 | 2.153E-002 | 9.203 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 9.203 | No |
3 | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 46.447 | 2.153E-002 | 5.619 | 2.559 | 0.000 | 0.000 | 0.000 | 0.000 | 8.177 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
1 | OFFICE PEOPLE | BLDG_OCC_SCH | ZONE1 OFFICE | 236.88 | 12.7 | 12.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | OFFICE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 13 |
2 | ZONE2 FINE STORAGEPEOPLE | BLDG_OCC_SCH | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 30.0 | 2.153E-002 | 46.447 | 0.300 | 0.700 | AutoCalculate | ZONE2 FINE STORAGE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 30 |
3 | ZONE3 BULK STORAGEPEOPLE | BLDG_OCC_SCH | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 69.0 | 2.153E-002 | 46.447 | 0.300 | 0.700 | AutoCalculate | ZONE3 BULK STORAGE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 69 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | OFFICE LIGHTS | LTG_SCH_OFFICE | ZONE1 OFFICE | 236.88 | 12.7 | 2131.000 | 8.996 | 167.154 | 0.000 | 0.370 | 0.180 | 0.450 | 1.000 | LightsWired | 0.000 | 2131.000 |
2 | FINE STORAGE AREA LIGHTS | LTG_SCH_FINE_STORAGE | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 12823.730 | 9.203 | 427.458 | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 12823.730 |
3 | BULK STORAGE AREA LIGHTS | LTG_SCH_BULK_STORAGE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 18007.220 | 5.619 | 260.974 | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 18007.220 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | OFFICE PLUG LOAD | OFFICE_PLUG_SCH | ZONE1 OFFICE | 236.88 | 12.7 | 1912.500 | 8.074 | 150.015 | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 1912.500 |
2 | BULK STORAGE PLUG LOAD | BULK STORAGE PLUG SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 8200.120 | 2.559 | 118.842 | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 8200.120 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | NONRES_ROOF | 16 | 2 | 2 | 0.167 | 0.2587 | 0.750 | 0.900 | 0.450 | 0.700 | Smooth |
2 | SEMIHEATED_ROOF | 18 | 2 | 2 | 0.167 | 0.2587 | 0.750 | 0.900 | 0.450 | 0.700 | Smooth |
3 | NONRES_EXT_WALL_GRD | 19 | 3 | 4 | 0.167 | 0.5832 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | SEMIHEATED_EXT_WALL_GRD | 25 | 3 | 4 | 0.167 | 0.5832 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | SWINGING DOOR_CON | 41 | 1 | 1 | 0.167 | 3.464 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
6 | SWINGING DOOR_SEMI | 42 | 1 | 1 | 0.167 | 3.464 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | OVERHEAD DOOR_SEMI | 44 | 1 | 1 | 0.167 | 1.198 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
8 | OVERHEAD DOOR_CON | 45 | 1 | 1 | 0.167 | 1.198 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
9 | BULK STORAGE PRODUCTS | 46 | 1 | 18 | 0.500 | 0.5914 | 0.900 | 0.900 | 0.700 | 0.700 | Rough |
10 | INTERIOR WALL | 47 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
11 | INSULATEDCEILING | 48 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
12 | OFFICEFLOOR_FFACTOR | 49 | 2 | 7 | 0.167 | 0.1926 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | FINESTORAGEFLOOR_FFACTOR | 50 | 2 | 7 | 0.167 | 0.7922E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | BULKSTORAGEFLOOR_FFACTOR | 51 | 2 | 7 | 0.167 | 0.7415E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | iz-INTERIOR WALL | 52 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
16 | iz-SEMIHEATED_EXT_WALL_GRD | 53 | 3 | 4 | 0.167 | 0.5832 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
17 | iz-INSULATEDCEILING | 54 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
2 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.865 |
3 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
4 | SEMIHEATED_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.865 |
5 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
6 | NONRES_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 1.615 |
7 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | SEMIHEATED_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 1.615 |
10 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
11 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2887 |
12 | OPAQUE DOOR PANEL_SEMI | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2887 |
13 | OVERHEAD DOOR_SEMI PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8346 |
14 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8346 |
15 | BULK STORAGE PRODUCTS MATERIAL | 2.4384 | 1.442 | 200.231 | 836.800 | 1.691 |
16 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
17 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
18 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
19 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
20 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
21 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
22 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
23 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 5.116 |
24 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
25 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.55 |
26 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
27 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 13.41 |
28 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
29 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
30 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
31 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
32 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
33 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
34 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
35 | SEMIHEATED_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 1.615 |
36 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
37 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
38 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 2 | 0.31452820E-09 | 0.26304591E-14 | 0.87829942E-15 | 0.0000000 |
2 | 1 | -5.2160429 | 0.46652437E-04 | -0.61920073E-04 | 0.60300157E-10 |
3 | 0 | 5.4747659 | 0.25867629 | 0.25878486 | |
4 | 2 | 0.31452820E-09 | 0.26304591E-14 | 0.87829942E-15 | 0.0000000 |
5 | 1 | -5.2160429 | 0.46652437E-04 | -0.61920073E-04 | 0.60300157E-10 |
6 | 0 | 5.4747659 | 0.25867629 | 0.25878486 | |
7 | 4 | 0.76147947E-12 | 0.16972320E-15 | -0.23941589E-14 | 0.12030052E-15 |
8 | 3 | -0.37802266E-03 | 0.40617527E-06 | -0.54770175E-04 | 0.14612398E-12 |
9 | 2 | 1.7236739 | 0.89444888E-02 | 1.1283884 | -0.72472748E-04 |
10 | 1 | -7.1497137 | 0.23277257 | -17.021073 | 0.33034766 |
11 | 0 | 5.8169840 | 0.14884880 | 16.283305 | |
12 | 4 | 0.76147947E-12 | 0.16972320E-15 | -0.23941589E-14 | 0.12030052E-15 |
13 | 3 | -0.37802266E-03 | 0.40617527E-06 | -0.54770175E-04 | 0.14612398E-12 |
14 | 2 | 1.7236739 | 0.89444888E-02 | 1.1283884 | -0.72472748E-04 |
15 | 1 | -7.1497137 | 0.23277257 | -17.021073 | 0.33034766 |
16 | 0 | 5.8169840 | 0.14884880 | 16.283305 | |
17 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
18 | 0 | 3.4637404 | 3.4637404 | 3.4637404 | |
19 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
20 | 0 | 3.4637404 | 3.4637404 | 3.4637404 | |
21 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
22 | 0 | 1.1981135 | 1.1981135 | 1.1981135 | |
23 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
24 | 0 | 1.1981135 | 1.1981135 | 1.1981135 | |
25 | 18 | 0.12003549E-12 | -0.36149852E-21 | 0.11999160E-12 | -0.69171859E-14 |
26 | 17 | -0.26702818E-10 | 0.22043783E-17 | -0.26702965E-10 | 0.15647703E-11 |
27 | 16 | 0.26199194E-08 | 0.46087291E-16 | 0.26199192E-08 | -0.15597178E-09 |
28 | 15 | -0.14918350E-06 | -0.27301975E-15 | -0.14918350E-06 | 0.90448703E-08 |
29 | 14 | 0.54929883E-05 | 0.10218664E-13 | 0.54929883E-05 | -0.34010628E-06 |
30 | 13 | -0.13812653E-03 | 0.13886261E-11 | -0.13812653E-03 | 0.87613853E-05 |
31 | 12 | 0.24466257E-02 | 0.76740851E-10 | 0.24466257E-02 | -0.15954016E-03 |
32 | 11 | -0.31099262E-01 | 0.20215154E-08 | -0.31099262E-01 | 0.20926433E-02 |
33 | 10 | 0.28694928 | 0.26940884E-07 | 0.28694928 | -0.20002833E-01 |
34 | 9 | -1.9353699 | 0.18750649E-06 | -1.9353699 | 0.14030665 |
35 | 8 | 9.5767226 | 0.68900696E-06 | 9.5767226 | -0.72468789 |
36 | 7 | -34.784653 | 0.13258951E-05 | -34.784653 | 2.7565275 |
37 | 6 | 92.438040 | 0.12976568E-05 | 92.438040 | -7.6923258 |
38 | 5 | -178.18614 | 0.60985027E-06 | -178.18614 | 15.604270 |
39 | 4 | 245.02895 | 0.12430126E-06 | 245.02895 | -22.615757 |
40 | 3 | -233.27712 | 0.91617964E-08 | -233.27712 | 22.714127 |
41 | 2 | 145.61910 | 0.16319500E-09 | 145.61910 | -14.964058 |
42 | 1 | -53.478849 | 0.26256209E-11 | -53.478849 | 5.7996512 |
43 | 0 | 8.7411694 | -0.39181092E-12 | 8.7411694 | |
44 | 5 | -0.68112304E-12 | 0.61645773E-13 | -0.20199983E-12 | 0.95058421E-15 |
45 | 4 | 0.71499529E-06 | 0.73238302E-07 | 0.28552134E-06 | -0.33479849E-12 |
46 | 3 | -0.58529659E-02 | 0.62218017E-03 | -0.21917430E-02 | 0.29169470E-06 |
47 | 2 | 1.2914758 | 0.88958368E-01 | 0.40042664 | -0.15953103E-02 |
48 | 1 | -8.6129398 | 0.38073474 | -3.1694576 | 0.22491773 |
49 | 0 | 7.9317533 | 0.13060792 | 3.3724149 | |
50 | 3 | -0.49407978E-15 | 0.44230608E-16 | -0.53860842E-16 | 0.0000000 |
51 | 2 | 0.54884850E-03 | 0.14309697E-03 | 0.26444340E-03 | -0.39739853E-15 |
52 | 1 | -3.9407614 | 2.0053241 | -3.6132068 | 0.31450573E-03 |
53 | 0 | 13.994357 | 8.0573072 | 13.672611 | |
54 | 7 | -0.21936956E-08 | -0.76657665E-15 | 0.52174295E-14 | -0.76362207E-16 |
55 | 6 | 0.54250385E-05 | 0.36865710E-08 | 0.31904099E-02 | -0.26763832E-04 |
56 | 5 | -0.38781740E-03 | 0.21819055E-05 | -0.22375527 | 0.19564212E-02 |
57 | 4 | 0.89061350E-02 | 0.99303795E-04 | 4.8300570 | -0.45269896E-01 |
58 | 3 | -0.78164548E-01 | 0.78949647E-03 | -38.024306 | 0.39868569 |
59 | 2 | 0.27748674 | 0.13132576E-02 | 116.48957 | -1.4180145 |
60 | 1 | -0.40047331 | 0.39992572E-03 | -143.91062 | 2.0490943 |
61 | 0 | 0.19524127 | 0.97244710E-05 | 60.838472 | |
62 | 7 | -0.53942680E-08 | -0.11156834E-13 | 0.16318657E-14 | -0.36257882E-16 |
63 | 6 | 0.25438785E-05 | 0.15223906E-08 | 0.31992327E-02 | -0.26837845E-04 |
64 | 5 | -0.16605865E-03 | 0.89659996E-06 | -0.22425660 | 0.19608463E-02 |
65 | 4 | 0.37075836E-02 | 0.40698259E-04 | 4.8384045 | -0.45350141E-01 |
66 | 3 | -0.32199378E-01 | 0.32283529E-03 | -38.071448 | 0.39920679 |
67 | 2 | 0.11382527 | 0.53586778E-03 | 116.58131 | -1.4192416 |
68 | 1 | -0.16395953 | 0.16275009E-03 | -143.96461 | 2.0499819 |
69 | 0 | 0.79856572E-01 | 0.39490086E-05 | 60.838472 | |
70 | 7 | -0.57660871E-08 | -0.13610624E-13 | 0.89936022E-15 | -0.28491615E-16 |
71 | 6 | 0.24333103E-05 | 0.14269892E-08 | 0.31996257E-02 | -0.26841142E-04 |
72 | 5 | -0.15663594E-03 | 0.83977476E-06 | -0.22427892 | 0.19610433E-02 |
73 | 4 | 0.34808858E-02 | 0.38103208E-04 | 4.8387759 | -0.45353710E-01 |
74 | 3 | -0.30176241E-01 | 0.30214868E-03 | -38.073544 | 0.39922996 |
75 | 2 | 0.10659492 | 0.50136596E-03 | 116.58539 | -1.4192962 |
76 | 1 | -0.15349297 | 0.15221123E-03 | -143.96701 | 2.0500213 |
77 | 0 | 0.74745977E-01 | 0.36906361E-05 | 60.838472 | |
78 | 5 | -0.20199983E-12 | 0.61645773E-13 | -0.68112304E-12 | 0.95058421E-15 |
79 | 4 | 0.28552134E-06 | 0.73238302E-07 | 0.71499529E-06 | -0.33479849E-12 |
80 | 3 | -0.21917430E-02 | 0.62218017E-03 | -0.58529659E-02 | 0.29169470E-06 |
81 | 2 | 0.40042664 | 0.88958368E-01 | 1.2914758 | -0.15953103E-02 |
82 | 1 | -3.1694576 | 0.38073474 | -8.6129398 | 0.22491773 |
83 | 0 | 3.3724149 | 0.13060792 | 7.9317533 | |
84 | 4 | -0.23941589E-14 | 0.16972320E-15 | 0.76147947E-12 | 0.12030052E-15 |
85 | 3 | -0.54770175E-04 | 0.40617527E-06 | -0.37802266E-03 | 0.14612398E-12 |
86 | 2 | 1.1283884 | 0.89444888E-02 | 1.7236739 | -0.72472748E-04 |
87 | 1 | -17.021073 | 0.23277257 | -7.1497137 | 0.33034766 |
88 | 0 | 16.283305 | 0.14884880 | 5.8169840 | |
89 | 3 | -0.53860842E-16 | 0.44230608E-16 | -0.49407978E-15 | 0.0000000 |
90 | 2 | 0.26444340E-03 | 0.14309697E-03 | 0.54884850E-03 | -0.39739853E-15 |
91 | 1 | -3.6132068 | 2.0053241 | -3.9407614 | 0.31450573E-03 |
92 | 0 | 13.672611 | 8.0573072 | 13.994357 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | Conductance (Before Adjusted) {W/m2-K} | Convection Coefficient Adjustment Ratio | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.504_SHGC_SOUTH_0.25 | 34 | 1 | VerySmooth | 2.865 | 2.865 | 1.000 | 0.251 | ||
2 | NONRESWINDOW_U_0.504_SHGC_NORTH_0.25 | 35 | 1 | VerySmooth | 2.865 | 2.865 | 1.000 | 0.251 | ||
3 | NONRESWINDOW_U_0.504_SHGC_EAST_0.25 | 36 | 1 | VerySmooth | 2.865 | 2.865 | 1.000 | 0.251 | ||
4 | NONRESWINDOW_U_0.504_SHGC_WEST_0.25 | 37 | 1 | VerySmooth | 2.865 | 2.865 | 1.000 | 0.251 | ||
5 | SKYLIGHT_U_0.9_SHGC_0.6 | 38 | 1 | VerySmooth | 5.108 | 5.108 | 1.000 | 0.601 | ||
6 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | 39 | 1 | VerySmooth | 5.108 | 5.108 | 1.000 | 0.601 | ||
7 | SKYLIGHT DOUBLE CLEAR | 43 | 3 | VerySmooth | 3.715 | 3.715 | 1.000 | 0.720 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER SOUTH | SpectralAverage | 1.91956E-002 | 0.16139 | 0.61064 | 0.61064 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.10739 | 1.00000 | No | |
2 | NONRES WINDOW GLAZING LAYER NORTH | SpectralAverage | 1.91956E-002 | 0.16139 | 0.61064 | 0.61064 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.10739 | 1.00000 | No | |
3 | NONRES WINDOW GLAZING LAYER EAST | SpectralAverage | 1.91956E-002 | 0.16139 | 0.61064 | 0.61064 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.10739 | 1.00000 | No | |
4 | NONRES WINDOW GLAZING LAYER WEST | SpectralAverage | 1.91956E-002 | 0.16139 | 0.61064 | 0.61064 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.10739 | 1.00000 | No | |
5 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.46039 | 0.10300 | 0.10300 | 0.60000 | 0.13030 | 0.15164 | 0.00000 | 0.84000 | 0.84000 | 6.93520E-002 | 1.00000 | No | |
6 | SEMIHEATED SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.46039 | 0.10300 | 0.10300 | 0.60000 | 0.13030 | 0.15164 | 0.00000 | 0.84000 | 0.84000 | 6.93520E-002 | 1.00000 | No | |
7 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No | |
8 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No |
Material Name | GasType | Thickness {m} | |
1 | AIR 3MM | Air | 3.200E-003 |
Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
Enclosure Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Enclosures | |
1 | ZONE1 OFFICE | 4 | 0 |
2 | ZONE2 FINE STORAGE | 14 | 0 |
3 | ZONE3 BULK STORAGE | 32 | 0 |
Enclosure Name | Number of Adjacent Enclosures with Windows | Adjacent Enclosure Names - 1st 100 (max) | |
1 | ZONE1 OFFICE | 0 | |
2 | ZONE2 FINE STORAGE | 0 | |
3 | ZONE3 BULK STORAGE | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 7.5708E-002 | 6154.7 | 1.055 | 0.5308 |
Construction Name | Frame and Divider Name | NFRC Product Type | Assembly U-Factor {W/m2-K} | Assembly SHGC | Assembly Visible Transmittance | |
1 | SKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | CurtainWall | 4.867 | 0.602 | 0.602 |
2 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | CurtainWall | 4.867 | 0.602 | 0.602 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | OFFICE INFILTRATION | OFFICE INFIL SCHEDULE | ZONE1 OFFICE | 236.88 | 12.7 | 8.518E-002 | 3.596E-004 | 5.551E-004 | 0.303 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | OFFICE DOOR INFILTRATION | INFIL_DOOR_OPENING_SCH | ZONE1 OFFICE | 236.88 | 12.7 | 0.289 | 1.219E-003 | 1.882E-003 | 1.029 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | FINE STORAGE INFILTRATION | FINE SORAGE INFIL SCHEDULE | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 0.433 | 3.110E-004 | 1.981E-004 | 0.528 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | BULK STORAGE INFILTRATION | BULK STORAGE INFIL_BASE SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 2.710 | 8.455E-004 | 5.523E-004 | 0.277 | 0.000 | 0.000 | 0.224 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
1 | BULK STORAGE VENTILATION-1 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 37.760 | 1.178E-002 | 0.547 | 3.853 | Exhaust | 31.136 | 0.5 | 1.000 | 0.000 | 0.000 | 0.000 | 29.44 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
2 | BULK STORAGE VENTILATION-2 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 0.944 | 2.945E-004 | 1.368E-002 | 9.632E-002 | Natural | 0.000 | 1.0 | 0.000 | 0.000 | 0.224 | 0.000 | -73.33 | 29.44 | -100.00 | -100.00 | 100.00 | 40.00 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | ZONE1 OFFICE | Mixing/Well-Stirred |
2 | ZONE2 FINE STORAGE | Mixing/Well-Stirred |
3 | ZONE3 BULK STORAGE | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Sky Type | MonthAndDay | Daylighting Control Name | Enclosure Name | Window Name | Reference Point | Daylight Factor | |
1 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.3640E-004 |
2 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.0952E-003 |
3 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.2527E-004 |
4 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.1656E-003 |
5 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.1866E-004 |
6 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.1398E-003 |
7 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.5848E-004 |
8 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT2 | 7.1816E-004 |
9 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.4487E-004 |
10 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT2 | 4.0018E-004 |
11 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.1367E-004 |
12 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT2 | 4.1730E-004 |
13 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.1982E-004 |
14 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT2 | 3.7479E-004 |
15 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.7680E-004 |
16 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.3855E-004 |
17 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT1 | 6.1212E-004 |
18 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.8089E-004 |
19 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.3491E-004 |
20 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.8417E-004 |
21 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT1 | 6.7538E-004 |
22 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.6612E-004 |
23 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.2141E-003 |
24 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.2648E-004 |
25 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.4446E-003 |
26 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.1755E-004 |
27 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.4057E-003 |
28 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.1864E-004 |
29 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.8046E-003 |
30 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.1153E-004 |
31 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.0450E-003 |
32 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.8226E-005 |
33 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.2995E-003 |
34 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.6364E-005 |
35 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.3792E-003 |
36 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.7208E-005 |
37 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.4013E-003 |
38 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.4725E-005 |
39 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.2695E-004 |
40 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.9692E-005 |
41 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT1 | 4.9541E-004 |
42 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.8157E-005 |
43 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.1986E-004 |
44 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.9041E-005 |
45 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT1 | 4.7092E-004 |
46 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.8640E-005 |
47 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.9222E-004 |
48 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.6649E-005 |
49 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT1 | 7.4387E-004 |
50 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.8569E-005 |
51 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT1 | 8.0483E-004 |
52 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.9446E-005 |
53 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT1 | 6.8555E-004 |
54 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.8939E-005 |
55 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.8087E-004 |
56 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.6800E-005 |
57 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.7311E-003 |
58 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.7624E-005 |
59 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT1 | 4.2960E-003 |
60 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.8476E-005 |
61 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.5039E-003 |
62 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.5677E-005 |
63 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.7041E-003 |
64 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.0163E-005 |
65 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT1 | 4.0243E-003 |
66 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.2220E-004 |
67 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT1 | 4.1955E-003 |
68 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.2347E-004 |
69 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.0736E-003 |
70 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.1523E-004 |
71 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.3936E-003 |
72 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.0000E-004 |
73 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0107E-003 |
74 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.0327E-004 |
75 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT1 | 8.8045E-004 |
76 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.0831E-004 |
77 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.1303E-003 |
78 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.8484E-004 |
79 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.4816E-003 |
80 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.3510E-004 |
81 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.0185E-004 |
82 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.5553E-004 |
83 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.5894E-004 |
84 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.9341E-004 |
85 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.6695E-004 |
86 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.0892E-004 |
87 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.2488E-004 |
88 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.9545E-004 |
89 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.4739E-004 |
90 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.6533E-003 |
91 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.3368E-004 |
92 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT2 | 3.0243E-003 |
93 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.2506E-004 |
94 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.4694E-003 |
95 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.7796E-004 |
96 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.2088E-003 |
97 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0510E-004 |
98 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT2 | 4.8537E-003 |
99 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0047E-004 |
100 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.2818E-003 |
101 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.5863E-005 |
102 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.8377E-003 |
103 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.1032E-004 |
104 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT2 | 4.8081E-003 |
105 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0238E-004 |
106 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.5716E-003 |
107 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.8428E-005 |
108 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.5728E-003 |
109 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.4671E-005 |
110 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.9345E-003 |
111 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0681E-004 |
112 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.8985E-003 |
113 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.2592E-005 |
114 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.2707E-005 |
115 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.8010E-005 |
116 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.3465E-005 |
117 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.4513E-005 |
118 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.6279E-005 |
119 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.6895E-005 |
120 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.7927E-005 |
121 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.9444E-005 |
122 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.0757E-005 |
123 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.0993E-005 |
124 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.4209E-005 |
125 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.4558E-005 |
126 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.8790E-005 |
127 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.2525E-005 |
128 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.8810E-005 |
129 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.2551E-005 |
130 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.5895E-005 |
131 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.7871E-005 |
132 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.4973E-005 |
133 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.3872E-005 |
134 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.4224E-005 |
135 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.6871E-005 |
136 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.6561E-005 |
137 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.6464E-004 |
138 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1812E-004 |
139 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7001E-004 |
140 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1837E-004 |
141 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4571E-004 |
142 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0896E-004 |
143 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.3769E-005 |
144 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.9618E-005 |
145 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.4044E-005 |
146 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.7931E-004 |
147 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.3703E-005 |
148 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.8606E-004 |
149 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.6950E-005 |
150 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.5809E-004 |
151 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.7372E-005 |
152 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.9357E-005 |
153 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.9316E-005 |
154 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9259E-005 |
155 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.8123E-005 |
156 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.8710E-005 |
157 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.3895E-005 |
158 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.8496E-005 |
159 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.7347E-005 |
160 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.6616E-005 |
161 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5854E-004 |
162 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.7465E-005 |
163 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.6257E-004 |
164 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.6122E-005 |
165 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4228E-004 |
166 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.4451E-005 |
167 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.3747E-005 |
168 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.6604E-005 |
169 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4907E-004 |
170 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.4675E-004 |
171 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4754E-004 |
172 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.9378E-004 |
173 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4334E-004 |
174 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9294E-004 |
175 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0580E-004 |
176 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.5939E-004 |
177 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 4.4583E-004 |
178 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.2911E-004 |
179 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 4.7722E-004 |
180 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.3052E-004 |
181 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 4.0857E-004 |
182 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.2422E-004 |
183 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2604E-004 |
184 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.5435E-004 |
185 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 4.1381E-004 |
186 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.5998E-005 |
187 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 4.3759E-004 |
188 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.2791E-005 |
189 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.8949E-004 |
190 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.3232E-005 |
191 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2591E-004 |
192 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.2647E-005 |
193 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3810E-004 |
194 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.2825E-005 |
195 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3463E-004 |
196 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.1688E-005 |
197 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3513E-004 |
198 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.1650E-005 |
199 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0571E-004 |
200 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9813E-005 |
201 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2989E-003 |
202 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0696E-004 |
203 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4166E-003 |
204 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0048E-004 |
205 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3387E-003 |
206 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0628E-004 |
207 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.8581E-004 |
208 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.9167E-005 |
209 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4979E-003 |
210 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.5012E-004 |
211 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.6659E-003 |
212 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.4866E-004 |
213 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4698E-003 |
214 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9326E-004 |
215 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.8668E-004 |
216 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.7823E-004 |
217 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.0891E-004 |
218 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.5914E-005 |
219 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.9885E-004 |
220 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.4095E-005 |
221 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2021E-004 |
222 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.4335E-005 |
223 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.9061E-004 |
224 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.3526E-005 |
225 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2856E-004 |
226 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.7158E-003 |
227 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2160E-004 |
228 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.1550E-003 |
229 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.3835E-004 |
230 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.3770E-003 |
231 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.9089E-004 |
232 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0419E-003 |
233 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4860E-004 |
234 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.7153E-005 |
235 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2708E-004 |
236 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.4810E-005 |
237 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.7324E-004 |
238 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.5043E-005 |
239 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9941E-004 |
240 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.6221E-005 |
241 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.1935E-003 |
242 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1697E-004 |
243 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2900E-003 |
244 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0701E-004 |
245 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.6841E-003 |
246 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1678E-004 |
247 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4248E-003 |
248 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.2491E-004 |
249 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4859E-003 |
250 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.0294E-004 |
251 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.6500E-003 |
252 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.7081E-004 |
253 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9693E-003 |
254 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.2594E-004 |
255 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4293E-003 |
256 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.8036E-004 |
257 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.6863E-004 |
258 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.3722E-003 |
259 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4941E-004 |
260 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.0759E-003 |
261 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9731E-004 |
262 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.0533E-003 |
263 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.0001E-004 |
264 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.9796E-003 |
265 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.0625E-004 |
266 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.5835E-005 |
267 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.8118E-004 |
268 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.3396E-005 |
269 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.1285E-004 |
270 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.3156E-005 |
271 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9778E-004 |
272 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.6189E-005 |
273 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.1617E-004 |
274 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.6952E-003 |
275 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.9176E-004 |
276 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.5694E-003 |
277 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2865E-004 |
278 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.0773E-003 |
279 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9837E-004 |
280 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.9047E-003 |
281 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0832E-003 |
282 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0659E-004 |
283 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.7832E-004 |
284 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.5917E-005 |
285 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3151E-003 |
286 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0189E-004 |
287 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.3879E-003 |
288 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.2457E-004 |
289 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1352E-003 |
290 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.3023E-004 |
291 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0362E-003 |
292 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.7801E-004 |
293 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3960E-003 |
294 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.8709E-004 |
295 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.3924E-003 |
296 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.7331E-004 |
297 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3792E-004 |
298 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.4039E-004 |
299 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2068E-004 |
300 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.7072E-004 |
301 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2890E-004 |
302 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.3837E-004 |
303 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.8861E-004 |
304 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0100E-003 |
305 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.6544E-004 |
306 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.1711E-004 |
307 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.0900E-004 |
308 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.8494E-004 |
309 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.6414E-004 |
310 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.0386E-004 |
311 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.6558E-004 |
312 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.7122E-004 |
313 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.9435E-005 |
314 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.4576E-005 |
315 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.0915E-005 |
316 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.1704E-005 |
317 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.4116E-005 |
318 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9181E-005 |
319 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.2504E-005 |
320 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.6374E-005 |
321 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3520E-004 |
322 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.2654E-005 |
323 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1771E-004 |
324 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.0569E-005 |
325 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2276E-004 |
326 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9789E-005 |
327 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.8833E-004 |
328 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.3453E-005 |
329 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.7530E-005 |
330 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.5950E-004 |
331 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.8216E-005 |
332 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.3497E-004 |
333 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.5503E-005 |
334 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.3048E-004 |
335 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0461E-004 |
336 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.5303E-004 |
337 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4581E-004 |
338 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1266E-004 |
339 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2429E-004 |
340 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.7799E-005 |
341 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2067E-004 |
342 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.2996E-005 |
343 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2098E-004 |
344 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.5178E-004 |
345 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.7036E-005 |
346 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9007E-005 |
347 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.7549E-005 |
348 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.7506E-005 |
349 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.3538E-005 |
350 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.6555E-005 |
351 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0452E-004 |
352 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9739E-005 |
353 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.6045E-004 |
354 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.5287E-005 |
355 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.0365E-004 |
356 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.7010E-005 |
357 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.5243E-004 |
358 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.6729E-005 |
359 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.6474E-004 |
360 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.8551E-005 |
361 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4538E-004 |
362 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.6572E-005 |
363 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2370E-004 |
364 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.1384E-005 |
365 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1869E-004 |
366 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.8590E-005 |
367 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2086E-004 |
368 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.2207E-005 |
369 | Clear Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 3.1535E-003 |
370 | Clear Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 3.8697E-004 |
371 | Clear Turbid Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 2.7545E-003 |
372 | Clear Turbid Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 3.5018E-004 |
373 | Intermediate Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 2.2792E-003 |
374 | Intermediate Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 3.1720E-004 |
375 | Overcast Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 1.7938E-003 |
376 | Overcast Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 3.1762E-004 |
377 | Clear Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 3.8460E-004 |
378 | Clear Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 3.6000E-003 |
379 | Clear Turbid Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 3.5109E-004 |
380 | Clear Turbid Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 3.0229E-003 |
381 | Intermediate Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 3.2075E-004 |
382 | Intermediate Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 2.4871E-003 |
383 | Overcast Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 3.1395E-004 |
384 | Overcast Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 2.4070E-003 |
385 | Clear Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 2.5932E-003 |
386 | Clear Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 1.9772E-004 |
387 | Clear Turbid Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 1.9890E-003 |
388 | Clear Turbid Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 1.6132E-004 |
389 | Intermediate Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 1.2013E-003 |
390 | Intermediate Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 1.2049E-004 |
391 | Overcast Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 2.2519E-003 |
392 | Overcast Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 1.9331E-004 |
393 | Clear Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 2.5843E-003 |
394 | Clear Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 1.9764E-004 |
395 | Clear Turbid Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 1.9918E-003 |
396 | Clear Turbid Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 1.6128E-004 |
397 | Intermediate Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 1.2447E-003 |
398 | Intermediate Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 1.2056E-004 |
399 | Overcast Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 2.2518E-003 |
400 | Overcast Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 1.9331E-004 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | ZONE1 OFFICE | Cooling | 11785.59489 | 14142.71387 | 0.97020 | 1.16425 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:50:00 | 34.77500 | 1.71573E-002 | 236.87965 | 12.74874 | 0.10228 | 0.00000 |
2 | ZONE1 OFFICE | Heating | 1302.29488 | 1562.75386 | 3.60319E-002 | 0.10228 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 20.10000 | 1.47983E-002 | 236.87965 | 12.74874 | 0.10228 | 0.00000 |
3 | ZONE2 FINE STORAGE | Cooling | 35800.23636 | 42960.28363 | 2.29762 | 2.75715 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:50:00 | 35.20000 | 1.71581E-002 | 1393.40969 | 30.00000 | 0.42471 | 0.00000 |
4 | ZONE2 FINE STORAGE | Heating | 0.00000 | 0.00000 | 0.00000 | 0.42471 | 00:10:00 | 20.10000 | 1.47983E-002 | 1393.40969 | 30.00000 | 0.42471 | 0.00000 | |
5 | ZONE3 BULK STORAGE | Cooling | 0.00000 | 0.00000 | 0.00000 | 0.97684 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:10:00 | 35.11500 | 1.71580E-002 | 3204.84228 | 69.00000 | 0.97684 | 0.00000 |
6 | ZONE3 BULK STORAGE | Heating | 0.00000 | 0.00000 | 0.00000 | 0.97684 | 00:10:00 | 20.10000 | 1.47983E-002 | 3204.84228 | 69.00000 | 0.97684 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-OFFICE | Cooling | Sensible | 18098.50 | 1.16425 | 1.16425 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
2 | PSZ-OFFICE | Heating | Sensible | 2461.78 | 0.10228 | 0.10228 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
3 | PSZ-FINE STORAGE | Cooling | Sensible | 53372.21 | 2.75715 | 2.75715 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
4 | PSZ-FINE STORAGE | Heating | Sensible | 10221.91 | 0.42471 | 0.42471 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ZONE1 OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.16425 |
2 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ZONE2 FINE STORAGE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 2.75715 |
3 | ZoneHVAC:UnitHeater | ZONE3 BULK STORAGE UNIT HEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.97684 |
4 | Fan:ConstantVolume | ZONE3UNITHEATER ZONE3HIRADIANT FAN | Design Size Maximum Flow Rate [m3/s] | 0.97684 |
5 | Coil:Heating:Fuel | ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | Design Size Nominal Capacity [W] | 39959.00499 |
6 | ZoneHVAC:HighTemperatureRadiant | ZONE3 BULK STORAGE HIRADIANT | User-Specified Heating Design Capacity [W] | 0.00000 |
7 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.16425 |
8 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.16425 |
9 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.16425 |
10 | AirLoopHVAC | PSZ-OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 1.16425 |
11 | AirLoopHVAC | PSZ-OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.16425 |
12 | AirLoopHVAC | PSZ-OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 1.16425 |
13 | AirLoopHVAC | PSZ-OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
14 | AirLoopHVAC | PSZ-OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.75715 |
16 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.75715 |
17 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.75715 |
18 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Heating Design Air Flow Rate [m3/s] | 2.75715 |
19 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.75715 |
20 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Main Design Air Flow Rate [m3/s] | 2.75715 |
21 | AirLoopHVAC | PSZ-FINE STORAGE | User Heating Air Flow Ratio [] | 1.00000 |
22 | AirLoopHVAC | PSZ-FINE STORAGE | Calculated Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-OFFICE | Design Supply Air Flow Rate [m3/s] | 1.16425 |
24 | AirLoopHVAC | PSZ-FINE STORAGE | Design Supply Air Flow Rate [m3/s] | 2.75715 |
25 | Controller:OutdoorAir | PSZ-OFFICE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.16425 |
26 | Controller:OutdoorAir | PSZ-OFFICE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.10228 |
27 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.16425 |
28 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 1289.00482 |
29 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.16425 |
30 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.16425 |
31 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.16425 |
32 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.76840 |
33 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.16425 |
34 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.58212 |
35 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.77617 |
36 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 24617.40000 |
37 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 12308.70000 |
38 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.75483 |
39 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.75483 |
40 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 24617.40000 |
41 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 26733.88843 |
42 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
43 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
44 | Coil:Heating:Fuel | PSZ-OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 26733.88843 |
45 | Controller:OutdoorAir | PSZ-FINE STORAGE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.75715 |
46 | Controller:OutdoorAir | PSZ-FINE STORAGE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.42471 |
47 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 2.75715 |
48 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 2950.27825 |
49 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 2.75715 |
50 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 2.75715 |
51 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.75715 |
52 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.81972 |
53 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 2.75715 |
54 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.37857 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.83810 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 68466.54000 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 34233.27000 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.70108 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.70108 |
60 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 68466.54000 |
61 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 123059.84120 |
62 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
63 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
64 | Coil:Heating:Fuel | PSZ-FINE STORAGE HEATING COIL | Design Size Nominal Capacity [W] | 123059.84120 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | 23713.1 | 11.94 | 11.67 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | 66323.4 | 12.06 | 11.79 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1Environment:Special Days |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | ZONE1 OFFICE | RunPeriod: RUNPERIOD 1 | 1.6753891398E-002 | 1.4368425147E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
2 | ZONE2 FINE STORAGE | RunPeriod: RUNPERIOD 1 | 0.1476957366 | 0.1954412919 | Pass | Pass | 0.3850258625 | 2.5788608881 | Pass | Pass |
3 | ZONE3 BULK STORAGE | RunPeriod: RUNPERIOD 1 | 1.6695926822E-002 | 1.5424470946E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Heat Emission by ComponentsEnvelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
Heat Emissions [GJ] | 7539.61 | 304.61 | 0.00 | -248.9 | 823.17 | 8418.50 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 20.10 | 0.00 | 20.10 | Wetbulb [C] | 1.80 | 0.00 |
HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 35.20 | 8.50 | 25.80 | Wetbulb [C] | 4.10 | 160.00 |
Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
Jan | 57.00 | 12 | |||
Feb | 0.00 | 0 | |||
Mar | 153.60 | 31 | |||
Apr | 87.00 | 59 | |||
May | 227.22 | 128 | |||
Jun | 144.58 | 109 | |||
Jul | 42.40 | 24 | |||
Aug | 164.90 | 163 | |||
Sep | 119.60 | 50 | |||
Oct | 365.70 | 188 | |||
Nov | 70.90 | 67 | |||
Dec | 0.00 | 0 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.536 | 0.583 | 110.54 | 97.44 | 270.00 | 90.00 | W |
OFFICE LEFT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.536 | 0.583 | 39.02 | 30.56 | 0.00 | 90.00 | N |
OFFICE FLOOR | OFFICEFLOOR_FFACTOR | 1.00 | 0.187 | 0.193 | 236.88 | 236.88 | 90.00 | 180.00 | |
FINE STORAGE FRONT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.536 | 0.583 | 169.07 | 161.64 | 270.00 | 90.00 | W |
FINE STORAGE RIGHT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.536 | 0.583 | 260.10 | 243.29 | 180.00 | 90.00 | S |
FINE STORAGE LEFT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.536 | 0.583 | 182.07 | 172.69 | 0.00 | 90.00 | N |
FINE STORAGE OFFICE FRONT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.536 | 0.583 | 110.54 | 110.54 | 270.00 | 90.00 | W |
FINE STORAGE OFFICE LEFT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.536 | 0.583 | 39.02 | 39.02 | 0.00 | 90.00 | N |
FINE STORAGE FLOOR | FINESTORAGEFLOOR_FFACTOR | 1.00 | 0.078 | 0.079 | 1156.53 | 1156.53 | 90.00 | 180.00 | |
FINE STORAGE ROOF | NONRES_ROOF | 0.55 | 0.250 | 0.259 | 1393.41 | 1372.60 | 90.00 | 0.00 | |
BULK STORAGE RIGHT WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.536 | 0.583 | 598.24 | 568.60 | 180.00 | 90.00 | S |
BULK STORAGE REAR WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.536 | 0.583 | 390.15 | 358.48 | 90.00 | 90.00 | E |
BULK STORAGE LEFT WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.536 | 0.583 | 598.24 | 544.27 | 0.00 | 90.00 | N |
BULK STORAGE FLOOR | BULKSTORAGEFLOOR_FFACTOR | 1.00 | 0.073 | 0.074 | 3204.84 | 3204.84 | 90.00 | 180.00 | |
BULK STORAGE ROOF | SEMIHEATED_ROOF | 0.55 | 0.250 | 0.259 | 3204.84 | 3157.28 | 270.00 | 0.00 |
Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE RIGHT WALL | INTERIOR WALL | 0.30 | 0.653 | 0.775 | 39.02 | 39.02 | 180.00 | 90.00 | S |
OFFICE REAR WALL | INTERIOR WALL | 0.30 | 0.653 | 0.775 | 110.54 | 110.54 | 90.00 | 90.00 | E |
OFFICE ROOF | INSULATEDCEILING | 0.30 | 2.711 | 10.063 | 236.88 | 236.88 | 90.00 | 0.00 | |
iz-OFFICE RIGHT WALL | iz-INTERIOR WALL | 0.30 | 0.653 | 0.775 | 39.02 | 39.02 | 0.00 | 90.00 | N |
iz-OFFICE REAR WALL | iz-INTERIOR WALL | 0.30 | 0.653 | 0.775 | 110.54 | 110.54 | 270.00 | 90.00 | W |
iz-BULK STORAGE FRONT WALL | iz-SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.512 | 0.583 | 390.15 | 390.15 | 270.00 | 90.00 | W |
iz-OFFICE ROOF | iz-INSULATEDCEILING | 0.30 | 2.711 | 10.063 | 236.88 | 236.88 | 270.00 | 180.00 | |
BULK STORAGE FRONT WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.512 | 0.583 | 390.15 | 390.15 | 90.00 | 90.00 | E |
BULK STORAGE PRODUCTS SURFACE | BULK STORAGE PRODUCTS | 0.30 | 0.591 | 6028.45 | 0.00 | 90.00 | N |
Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL WINDOW 1 | NONRESWINDOW_U_0.504_SHGC_WEST_0.25 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 2.865 | 0.251 | 0.251 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | |||||||
OFFICE FRONT WALL WINDOW2 | NONRESWINDOW_U_0.504_SHGC_WEST_0.25 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 2.865 | 0.251 | 0.251 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | |||||||
OFFICE LEFT WALL WINDOW1 | NONRESWINDOW_U_0.504_SHGC_NORTH_0.25 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 2.865 | 0.251 | 0.251 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | |||||||
OFFICE LEFT WALL WINDOW2 | NONRESWINDOW_U_0.504_SHGC_NORTH_0.25 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 2.865 | 0.251 | 0.251 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | |||||||
FINESTORAGE_SKYLIGHT_1 | SKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_6 | SKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_7 | SKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_8 | SKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_9 | SKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_10 | SKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_5 | SKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_4 | SKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_3 | SKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_2 | SKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_14 | SKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_13 | SKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_12 | SKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_11 | SKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R8C1 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R8C2 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R8C4 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R1C2 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R1C1 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R1C4 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R1C3 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R2C1 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R2C2 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R2C3 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R2C4 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R3C4 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R3C2 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R3C3 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R3C1 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R4C4 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R4C3 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R4C2 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R4C1 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R5C4 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R5C1 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R5C3 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R5C2 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R6C1 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R6C2 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R8C3 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R6C4 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R7C1 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R7C2 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R7C4 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R6C3 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R7C3 | SEMIHTDSKYLIGHT_U_0.9_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.601 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.867 | 0.602 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
Total or Average | 86.04 | 4.647 | 0.529 | 0.530 | |||||||||||||||||
North Total or Average | 6.51 | 2.865 | 0.251 | 0.251 | |||||||||||||||||
Non-North Total or Average | 79.53 | 4.793 | 0.552 | 0.553 |
Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
None |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
OFFICE FRONT DOOR | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | OFFICE FRONT WALL |
OFFICE LEFT WALL DOOR | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | OFFICE LEFT WALL |
FINE STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_CON | 1.016 | 1.198 | 7.43 | FINE STORAGE FRONT WALL |
FINE STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_CON | 1.016 | 1.198 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_CON | 1.016 | 1.198 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE RIGHT DOOR | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_CON | 1.016 | 1.198 | 7.43 | FINE STORAGE LEFT WALL |
FINE STORAGE LEFT DOOR | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | FINE STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR8 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR9 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR10 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR11 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR1 | SWINGING DOOR_SEMI | 2.281 | 3.464 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR2 | SWINGING DOOR_SEMI | 2.281 | 3.464 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR3 | SWINGING DOOR_SEMI | 2.281 | 3.464 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR12 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR13 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR14 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR15 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE DOOR4 | SWINGING DOOR_SEMI | 2.281 | 3.464 | 1.95 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR5 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR6 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR7 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE DOOR5 | SWINGING DOOR_SEMI | 2.281 | 3.464 | 1.95 | BULK STORAGE LEFT WALL |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
OFFICE FRONT WALL WINDOW 1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE FRONT WALL WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE LEFT WALL WINDOW1 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
OFFICE LEFT WALL WINDOW2 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
FINESTORAGE_SKYLIGHT_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_6 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_7 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_8 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_9 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_10 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_5 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_14 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_13 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R8C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R8C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R8C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R3C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R3C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R3C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R3C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R4C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R4C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R4C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R4C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R5C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R5C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R5C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R5C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R6C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R6C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R8C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R6C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R7C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R7C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R7C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R6C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R7C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Interior LightingZone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
OFFICE LIGHTS | ZONE1 OFFICE | ZONE1 OFFICE | GENERAL | 8.9961 | 236.88 | 2131.00 | LightsWired | LTG_SCH_OFFICE | 51.55 | 168.00 | 45.68 | 0.0000 | Y | 18.27 |
FINE STORAGE AREA LIGHTS | ZONE2 FINE STORAGE | ZONE2 FINE STORAGE | GENERAL | 9.2031 | 1393.41 | 12823.73 | LightsWired | LTG_SCH_FINE_STORAGE | 34.09 | 168.00 | 22.06 | 0.0000 | Y | 53.09 |
BULK STORAGE AREA LIGHTS | ZONE3 BULK STORAGE | ZONE3 BULK STORAGE | GENERAL | 5.6188 | 3204.84 | 18007.22 | LightsWired | LTG_SCH_BULK_STORAGE | 34.09 | 168.00 | 20.25 | 0.0000 | Y | 68.44 |
Interior Lighting Total | 6.8172 | 4835.13 | 32961.95 | 139.81 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
ZONE2 FINE STORAGE_DAYLREFPT1 | ZONE2 FINE STORAGE | ZONE2 FINE STORAGE_DAYLCTRL | SplitFlux | Stepped | 0.25 | 12823.73 | 3205.93 |
ZONE2 FINE STORAGE_DAYLREFPT2 | ZONE2 FINE STORAGE | ZONE2 FINE STORAGE_DAYLCTRL | SplitFlux | Stepped | 0.25 | 12823.73 | 3205.93 |
ZONE3 BULK STORAGE_DAYLREFPT1 | ZONE3 BULK STORAGE | ZONE3 BULK STORAGE_DAYLCTRL | SplitFlux | Stepped | 0.25 | 18007.22 | 4501.81 |
ZONE3 BULK STORAGE_DAYLREFPT2 | ZONE3 BULK STORAGE | ZONE3 BULK STORAGE_DAYLCTRL | SplitFlux | Stepped | 0.25 | 18007.22 | 4501.81 |
ZONE1 OFFICE_DAYLREFPT1 | ZONE1 OFFICE | ZONE1 OFFICE_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 2131.00 | 309.00 |
ZONE1 OFFICE_DAYLREFPT2 | ZONE1 OFFICE | ZONE1 OFFICE_DAYLCTRL | SplitFlux | Continuous/Off | 0.05 | 2131.00 | 106.55 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 94.73 | AstronomicalClock | - | 41.93 | 41.93 | 0.75 | |
EXTERIOR_LIGHTS_B | 6863.48 | AstronomicalClock | - | 83.83 | 71.26 | 91.81 | |
Exterior Lighting Total | 6958.21 | 92.56 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Central PlantType | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 24617.40 | 18581.95 | 6035.45 | 0.75 | 3.80 | |||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 68466.54 | 48000.52 | 20466.02 | 0.70 | 3.73 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-OFFICE COOLING COIL | 23713.1 | 11.94 | 11.67 | ||||
PSZ-FINE STORAGE COOLING COIL | 66323.4 | 12.06 | 11.79 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | Coil:Heating:Fuel | 39959.00 | 0.80 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | 26733.89 | 0.80 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | 123059.84 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
ZONE3UNITHEATER ZONE3HIRADIANT FAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.98 | 90.76 | 92.91 | 1.00 | 4.17 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.56 | 622.50 | 1.16 | 1289.00 | 1107.16 | 1.00 | 1.37 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.58 | 622.50 | 2.76 | 2950.28 | 1070.05 | 1.00 | 1.27 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SWHSYS1 WATER HEATER | WaterHeater:Mixed | 0.08 | 6154.75 | 1.00 | 1.06 | 0.53 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 11785.59 | 14142.71 | 59.70 | 0.970 | 1.164 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:50:00 | 23.90 | 23.90 | 0.00859 | 34.78 | 0.01716 | 0.102 | 0.00 |
ZONE2 FINE STORAGE | 35800.24 | 42960.28 | 30.83 | 2.298 | 2.757 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:50:00 | 26.70 | 26.70 | 0.00927 | 35.20 | 0.01716 | 0.425 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 | 0.000 | 0.977 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:10:00 | 0.00 | 35.02 | 0.01724 | 35.12 | 0.01716 | 0.977 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 1302.29 | 1562.75 | 6.60 | 0.036 | 0.102 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 21.10 | 21.10 | 0.01443 | 20.10 | 0.01480 | 0.102 | 0.00 |
ZONE2 FINE STORAGE | 0.00 | 0.00 | 0.00 | 0.000 | 0.425 | 00:10:00 | 15.56 | 18.86 | 0.01368 | 20.10 | 0.01480 | 0.425 | 0.00 | |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 | 0.000 | 0.977 | 00:10:00 | 10.00 | 20.20 | 0.01489 | 20.10 | 0.01480 | 0.977 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-OFFICE | 1.16 | 1.16 | 0.10 | 0.10 | 1.1642 | 1.1642 | 1.1642 | 1.0000 | 1.0000 |
PSZ-FINE STORAGE | 2.76 | 2.76 | 0.42 | 0.42 | 2.7571 | 2.7571 | 2.7571 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER or ZONEHVAC:HIGHTEMPERATURERADIANT | ZONE3 BULK STORAGE UNIT HEATER or ZONE3 BULK STORAGE HIRADIANT | 39959.005 | 39959.005 | -999.0 | -999.0 | -999.000 | 12/21 00:10:00 | 12/21 00:10:00 | 39959.00 | 39959.00 | 0.976836 | 10.00 | 10.00 | 0.00800000 | 43.33 | 22.14 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 10.00 | 0.00800000 | 100.0000 | 0.00 | 0.00 | -999.00 | -999.00 | ||
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-OFFICE | 24617.400 | 18581.952 | 1.164250 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:50:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:50:00 | 12308.70 | 10072.00 | 0.776167 | 25.75 | 17.69 | 0.00933827 | 12.00 | 11.25 | 0.00800000 | 34.78 | 0.01715734 | 25.72 | 13.1782 | 23.90 | 0.00858516 | 46.4715 | 11785.59 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-OFFICE | 26733.888 | 26733.888 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 26733.89 | 26733.89 | 1.164246 | 21.01 | 20.17 | 0.01451044 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 8.7855 | 19.76 | 0.01448271 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-FINE STORAGE | 68466.540 | 48000.522 | 2.757150 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:50:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:50:00 | 34233.27 | 25504.37 | 1.838100 | 28.87 | 19.62 | 0.01048411 | 12.00 | 11.25 | 0.00800000 | 35.20 | 0.01715815 | 25.83 | 23.1060 | 26.70 | 0.00926884 | 42.4343 | 35800.24 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-FINE STORAGE | 123059.841 | 123059.841 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 123059.84 | 123059.84 | 2.757148 | 3.10 | 3.10 | 0.01385199 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 15.4040 | 18.86 | 0.01367968 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER or ZONEHVAC:HIGHTEMPERATURERADIANT | ZONE3 BULK STORAGE UNIT HEATER or ZONE3 BULK STORAGE HIRADIANT | ZONE3 BULK STORAGE | N/A | N/A | N/A | Yes | No | unknown | No | 39959.005 | 39959.005 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | ZONE3UNITHEATER ZONE3HIRADIANT FAN | Fan:ConstantVolume | 0.976836 | 1.17571482 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | 12/21 00:10:00 | unknown | unknown | 12/21 00:10:00 | Sensible | 39959.00 | 39959.00 | 1.0000 | 1.17571482 | 0.976836 | 10.00 | 10.00 | 0.00800000 | 30204.6 | 43.33 | 22.14 | 0.00800000 | 64191.6 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 39959.00 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 10.00 | 0.00800000 | 10.00 | 0.00800000 | 100.0000 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |||
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 24617.400 | 18581.952 | 1.164250 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.1994 | 1004.8586 | 1.2036 | PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 1.164246 | 1.40128030 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:50:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:50:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:50:00 | Sensible | 12308.70 | 10072.00 | 1.0000 | 0.93419030 | 0.776167 | 25.75 | 17.69 | 0.00933827 | 49679.3 | 12.00 | 11.25 | 0.00800000 | 32244.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12308.70 | 34.78 | 0.01715734 | 25.72 | 0.10228463 | 13.1782 | 23.90 | 0.00858516 | 23.90 | 0.00858516 | 46.4715 | 11785.59 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 26733.888 | 26733.888 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 1.164246 | 1.40128030 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 26733.89 | 26733.89 | 1.0000 | 1.40128030 | 1.164246 | 21.01 | 20.17 | 0.01451044 | 57972.3 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 26733.89 | 20.10 | 0.01479830 | 20.10 | 0.10228463 | 8.7855 | 21.10 | 0.01448271 | 19.76 | 0.01448271 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 68466.540 | 48000.522 | 2.757150 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.3294 | 1004.8586 | 1.2036 | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 2.757148 | 3.31848900 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:50:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:50:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:50:00 | Sensible | 34233.27 | 25504.37 | 1.0000 | 2.21232794 | 1.838100 | 28.87 | 19.62 | 0.01048411 | 55796.1 | 12.00 | 11.25 | 0.00800000 | 32244.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 34233.27 | 35.20 | 0.01715815 | 25.83 | 0.42471127 | 23.1060 | 26.70 | 0.00926884 | 26.70 | 0.00926884 | 42.4343 | 35800.24 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 123059.841 | 123059.841 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 2.757148 | 3.31848900 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | Sensible | 123059.84 | 123059.84 | 1.0000 | 3.31848900 | 2.757148 | 3.10 | 3.10 | 0.01385199 | 37833.9 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 123059.84 | 20.10 | 0.01479830 | 20.10 | 0.42471127 | 15.4040 | 0.00 | 0.01367968 | 18.86 | 0.01367968 | 99.9999 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
ZONE1 OFFICE | 3636.00 | 1120.33 | 1120.33 |
ZONE2 FINE STORAGE | 3636.00 | 3626.00 | 3626.00 |
ZONE3 BULK STORAGE | 3636.00 | 3636.00 | 3636.00 |
Facility | 3636.00 | 3636.00 | 3636.00 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
ZONE1 OFFICE | 0.00 | 23.00 | 0.00 | 16.67 |
ZONE2 FINE STORAGE | 0.00 | 304.17 | 0.00 | 8.33 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 0.00 | 327.17 | 0.00 | 25.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 9.53 | 12.75 | 1010.76 | 0.347 | 0.375 | 0.000 | 0.000 |
ZONE2 FINE STORAGE | 22.44 | 30.00 | 2953.02 | 0.499 | 0.158 | 0.000 | 0.000 |
ZONE3 BULK STORAGE | 51.60 | 69.00 | 35277.63 | 0.000 | 0.100 | 0.000 | 2.513 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 9.53 | 12.75 | 1010.76 | 0.000 | 0.000 | 0.000 | 0.000 |
ZONE2 FINE STORAGE | 22.44 | 30.00 | 2953.02 | 0.000 | 0.000 | 0.000 | 0.000 |
ZONE3 BULK STORAGE | 51.60 | 69.00 | 35277.63 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Mechanical Ventilation Parameters by ZoneAirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
ZONE1 OFFICE | PSZ-OFFICE | 9.53 | 12.75 | 1010.76 | 236.88 | 0.1023 | 0.102 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 22.44 | 30.00 | 2953.02 | 1393.41 | 0.4247 | 0.425 |
ZONE3 BULK STORAGE | 51.60 | 69.00 | 35277.63 | 3204.84 | 0.977 | ||
Total Facility | 83.57 | 111.75 | 39241.41 | 4835.13 | 0.5270 | 1.504 |
Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
ZONE1 OFFICE | 1237846.11 | 0.00 | 1237846.11 | 1771116.47 | 3008962.58 | 3225648.14 | 5426.17 | 3333.83 | 0.00 | 117.18 |
ZONE2 FINE STORAGE | 5986449.75 | 0.00 | 5986449.75 | 4070082.89 | 10056532.64 | 13393694.68 | 5403.09 | 3356.91 | 0.00 | 2086.74 |
ZONE3 BULK STORAGE | 0.00 | 0.46E+09 | 0.46E+09 | 23593493.67 | 0.49E+09 | 30805497.77 | 5144.79 | 0.22 | 3614.98 | 4937.56 |
Total Facility | 7224295.86 | 0.46E+09 | 0.47E+09 | 29434693.03 | 0.50E+09 | 47424840.58 | 6408.76 | 3357.97 | 3614.98 | 4976.59 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
ZONE1 OFFICE | 0.0940 | 0.0000 | 0.0940 | 0.1013 | 0.1954 | 0.1023 | 302.17 | 3333.83 | 0.00 |
ZONE2 FINE STORAGE | 0.3908 | 0.0000 | 0.3908 | 0.1235 | 0.5143 | 0.4247 | 303.00 | 3333.00 | 0.00 |
ZONE3 BULK STORAGE | 0.0000 | 22.9526 | 22.9526 | 0.9167 | 23.8693 | 0.9768 | 1273.93 | 0.00 | 2362.07 |
Total Facility | 0.4848 | 22.9526 | 23.4374 | 1.1415 | 24.5789 | 1.5038 | 1284.76 | 3333.83 | 2362.07 |
Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
PSZ-OFFICE | 1793244.46 | 0.00 | 1793244.46 | 3225648.14 | 5420.13 | 0.94 | 3338.94 | 115.16 |
PSZ-FINE STORAGE | 8672241.21 | 0.00 | 8672241.21 | 13393694.68 | 5300.49 | 17.76 | 3441.75 | 2085.41 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
PSZ-OFFICE | 0.1362 | 0.0000 | 0.1362 | 0.1023 | 299.09 | 0.47 | 3336.44 |
PSZ-FINE STORAGE | 0.5661 | 0.0000 | 0.5661 | 0.4247 | 301.19 | 0.42 | 3334.39 |
No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
PSZ-OFFICE | 0.00 | 3479.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PSZ-FINE STORAGE | 0.00 | 5477.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
PSZ-OFFICE | 0.0000 | 0.1472 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
PSZ-FINE STORAGE | 0.0000 | 0.6068 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Surfaces by ClassTotal | Outdoors | |
Wall | 16 | 10 |
Floor | 4 | 3 |
Roof | 3 | 2 |
Internal Mass | 1 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 50 | 50 |
Door | 28 | 28 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 2 |
Conditioned Zones | 3 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 429 |
Defaulted Fields | 391 |
Fields with Defaults | 1171 |
Autosized Fields | 43 |
Autosizable Fields | 97 |
Autocalculated Fields | 128 |
Autocalculatable Fields | 206 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 610.17 | 2150.68 | 02-JUL-14:20 | 44160.05 | 06-MAY-15:10 |
Electricity:Building | 309.07 | 1663.58 | 06-AUG-15:10 | 26381.24 | 11-DEC-17:00 |
Electricity:Zone:ZONE1 OFFICE | 50.22 | 815.73 | 08-JAN-15:30 | 3175.05 | 18-DEC-16:50 |
Electricity:SpaceType:GENERAL | 279.10 | 1663.58 | 22-JAN-15:10 | 24089.59 | 18-DEC-17:00 |
InteriorLights:Electricity | 139.81 | 1089.83 | 22-JAN-15:10 | 13976.97 | 18-DEC-17:00 |
InteriorLights:Electricity:Zone:ZONE1 OFFICE | 18.27 | 241.98 | 08-JAN-15:30 | 1262.55 | 18-DEC-16:50 |
InteriorLights:Electricity:SpaceType:GENERAL | 139.81 | 1089.83 | 22-JAN-15:10 | 13976.97 | 18-DEC-17:00 |
LightsWired:InteriorLights:Electricity | 139.81 | 1089.83 | 22-JAN-15:10 | 13976.97 | 18-DEC-17:00 |
LightsWired:InteriorLights:Electricity:Zone:ZONE1 OFFICE | 18.27 | 241.98 | 08-JAN-15:30 | 1262.55 | 18-DEC-16:50 |
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 139.81 | 1089.83 | 22-JAN-15:10 | 13976.97 | 18-DEC-17:00 |
Electricity:Zone:ZONE2 FINE STORAGE | 53.09 | 352.65 | 01-JAN-09:50 | 5495.50 | 18-DEC-16:00 |
InteriorLights:Electricity:Zone:ZONE2 FINE STORAGE | 53.09 | 352.65 | 01-JAN-09:50 | 5495.50 | 18-DEC-16:00 |
LightsWired:InteriorLights:Electricity:Zone:ZONE2 FINE STORAGE | 53.09 | 352.65 | 01-JAN-09:50 | 5495.50 | 18-DEC-16:00 |
Electricity:Zone:ZONE3 BULK STORAGE | 205.75 | 495.20 | 01-JAN-07:50 | 17933.39 | 14-NOV-17:00 |
InteriorLights:Electricity:Zone:ZONE3 BULK STORAGE | 68.44 | 495.20 | 01-JAN-07:50 | 7427.98 | 09-NOV-17:00 |
LightsWired:InteriorLights:Electricity:Zone:ZONE3 BULK STORAGE | 68.44 | 495.20 | 01-JAN-07:50 | 7427.98 | 09-NOV-17:00 |
InteriorEquipment:Electricity | 139.29 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE1 OFFICE | 31.95 | 573.75 | 01-JAN-00:10 | 1912.50 | 02-JAN-08:10 |
InteriorEquipment:Electricity:SpaceType:GENERAL | 139.29 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity | 139.29 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ZONE1 OFFICE | 31.95 | 573.75 | 01-JAN-00:10 | 1912.50 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 139.29 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE3 BULK STORAGE | 107.34 | 0.00 | 01-JAN-00:10 | 8200.12 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ZONE3 BULK STORAGE | 107.34 | 0.00 | 01-JAN-00:10 | 8200.12 | 02-JAN-08:10 |
Fans:Electricity | 56.72 | 0.00 | 01-JAN-00:10 | 5268.55 | 06-MAY-15:10 |
Fans:Electricity:Zone:ZONE3 BULK STORAGE | 29.97 | 0.00 | 01-JAN-00:10 | 2305.29 | 11-JAN-08:30 |
Ventilation (simple):Fans:Electricity | 29.97 | 0.00 | 01-JAN-00:10 | 2305.29 | 11-JAN-08:30 |
Ventilation (simple):Fans:Electricity:Zone:ZONE3 BULK STORAGE | 29.97 | 0.00 | 01-JAN-00:10 | 2305.29 | 11-JAN-08:30 |
ElectricityPurchased:Facility | 610.17 | 2150.68 | 02-JUL-14:20 | 44160.05 | 06-MAY-15:10 |
ElectricityPurchased:Plant | 610.17 | 2150.68 | 02-JUL-14:20 | 44160.05 | 06-MAY-15:10 |
Cogeneration:ElectricityPurchased | 610.17 | 2150.68 | 02-JUL-14:20 | 44160.05 | 06-MAY-15:10 |
General:Cogeneration:ElectricityPurchased | 610.17 | 2150.68 | 02-JUL-14:20 | 44160.05 | 06-MAY-15:10 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 610.17 | 2150.68 | 02-JUL-14:20 | 44160.05 | 06-MAY-15:10 |
ElectricityNet:Plant | 610.17 | 2150.68 | 02-JUL-14:20 | 44160.05 | 06-MAY-15:10 |
Cogeneration:ElectricityNet | 610.17 | 2150.68 | 02-JUL-14:20 | 44160.05 | 06-MAY-15:10 |
General:Cogeneration:ElectricityNet | 610.17 | 2150.68 | 02-JUL-14:20 | 44160.05 | 06-MAY-15:10 |
Electricity:HVAC | 186.44 | 0.00 | 01-JAN-00:10 | 22492.86 | 06-MAY-15:10 |
General:Fans:Electricity | 26.75 | 0.00 | 01-JAN-00:10 | 2963.25 | 06-MAY-15:10 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 159.69 | 0.00 | 01-JAN-00:10 | 19529.61 | 06-MAY-15:10 |
General:Cooling:Electricity | 159.69 | 0.00 | 01-JAN-00:10 | 19529.61 | 06-MAY-15:10 |
ExteriorLights:Electricity | 92.56 | 0.00 | 01-JAN-06:20 | 6958.21 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 92.56 | 0.00 | 01-JAN-06:20 | 6958.21 | 01-JAN-06:10 |
Electricity:Plant | 22.10 | 483.00 | 24-JAN-09:30 | 1704.69 | 11-JAN-12:30 |
WaterSystems:Electricity | 22.10 | 483.00 | 24-JAN-09:30 | 1704.69 | 11-JAN-12:30 |
Water Heater:WaterSystems:Electricity | 22.10 | 483.00 | 24-JAN-09:30 | 1704.69 | 11-JAN-12:30 |
Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
NaturalGas:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
NaturalGas:HVAC | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Heating:NaturalGas | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:NaturalGas | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
EnergyTransfer:Facility | 1008.30 | 0.00 | 01-JAN-00:10 | 113866.15 | 06-MAY-15:10 |
EnergyTransfer:Building | 344.82 | 0.00 | 01-JAN-00:10 | 41064.87 | 06-MAY-15:10 |
EnergyTransfer:Zone:ZONE1 OFFICE | 100.63 | 0.00 | 01-JAN-00:10 | 13077.26 | 01-MAY-12:00 |
Heating:EnergyTransfer | 0.07 | 0.00 | 01-JAN-00:10 | 671.03 | 18-FEB-07:10 |
Heating:EnergyTransfer:Zone:ZONE1 OFFICE | 0.06 | 0.00 | 01-JAN-00:10 | 548.38 | 04-MAR-07:20 |
General:Heating:EnergyTransfer | 0.07 | 0.00 | 01-JAN-00:10 | 671.03 | 18-FEB-07:10 |
General:Heating:EnergyTransfer:Zone:ZONE1 OFFICE | 0.06 | 0.00 | 01-JAN-00:10 | 548.38 | 04-MAR-07:20 |
Cooling:EnergyTransfer | 344.75 | 0.00 | 01-JAN-00:10 | 41064.87 | 06-MAY-15:10 |
Cooling:EnergyTransfer:Zone:ZONE1 OFFICE | 100.57 | 0.00 | 01-JAN-00:10 | 13077.26 | 01-MAY-12:00 |
General:Cooling:EnergyTransfer | 344.75 | 0.00 | 01-JAN-00:10 | 41064.87 | 06-MAY-15:10 |
General:Cooling:EnergyTransfer:Zone:ZONE1 OFFICE | 100.57 | 0.00 | 01-JAN-00:10 | 13077.26 | 01-MAY-12:00 |
EnergyTransfer:Zone:ZONE2 FINE STORAGE | 244.19 | 0.00 | 01-JAN-00:10 | 29956.56 | 06-MAY-15:10 |
Heating:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 0.02 | 0.00 | 01-JAN-00:10 | 510.40 | 22-MAY-06:10 |
General:Heating:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 0.02 | 0.00 | 01-JAN-00:10 | 510.40 | 22-MAY-06:10 |
Cooling:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 244.17 | 0.00 | 01-JAN-00:10 | 29956.56 | 06-MAY-15:10 |
General:Cooling:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 244.17 | 0.00 | 01-JAN-00:10 | 29956.56 | 06-MAY-15:10 |
EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Heating:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cooling:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 663.48 | 0.00 | 01-JAN-00:10 | 73953.64 | 13-JUN-15:50 |
HeatingCoils:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
CoolingCoils:EnergyTransfer | 663.48 | 0.00 | 01-JAN-00:10 | 73953.64 | 13-JUN-15:50 |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
ZONE1 OFFICE | 0.000 | 0.000 | 0.058 | -100.570 | 0.000 | 0.000 | 9.037 | 18.272 | 31.946 | 14.070 | 0.000 | 8.317 | 22.367 | 0.000 | -2.126 | 0.000 | -1.372 | -0.001 |
ZONE2 FINE STORAGE | 0.000 | 0.000 | 0.016 | -244.161 | 0.000 | 0.000 | 17.086 | 53.095 | 0.000 | 78.663 | 0.000 | 9.490 | 95.910 | 0.000 | -6.697 | 0.000 | -3.401 | -0.000 |
ZONE3 BULK STORAGE | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22.723 | 68.444 | 107.344 | 956.044 | 0.000 | 41.765 | 0.005 | 0.000 | -94.425 | 0.000 | -397.812 | -704.082 |
Total Facility | 0.000 | 0.000 | 0.073 | -344.731 | 0.000 | 0.000 | 48.846 | 139.811 | 139.290 | 1048.777 | 0.000 | 59.572 | 118.282 | 0.000 | -103.249 | 0.000 | -402.584 | -704.083 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 23-FEB-07:01 | 0.00 | 0.00 | 0.00 | -20091.97 | 0.00 | 0.00 | 134.67 | 668.07 | 956.25 | 0.00 | 0.00 | 0.00 | 20218.71 | 0.00 | -49.95 | 0.00 | -1835.79 | 0.00 |
ZONE2 FINE STORAGE | 16-JAN-16:53 | 0.00 | 0.00 | 0.00 | -53329.51 | 0.00 | 0.00 | 0.00 | 705.31 | 0.00 | 807.58 | 0.00 | 725.20 | 51091.42 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 17-JUL-06:01 | 0.00 | 0.00 | 0.00 | -66116.53 | 0.00 | 0.00 | 1078.09 | 9860.01 | 3006.28 | 171.07 | 0.00 | 0.00 | 55637.00 | 0.00 | -155.89 | 0.00 | -3480.03 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 18-FEB-07:06 | 0.00 | 0.00 | 868.38 | 0.00 | 0.00 | 0.00 | 129.70 | 680.01 | 956.25 | 91.18 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2725.53 |
ZONE2 FINE STORAGE | 05-MAY-06:03 | 0.00 | 0.00 | 2127.68 | 0.00 | 0.00 | 0.00 | 356.79 | 4231.83 | 0.00 | 597.47 | 0.00 | 558.09 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -7871.86 |
ZONE3 BULK STORAGE | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 05-MAY-06:03 | -10509.14 | 10509.14 | 2127.68 | -10509.14 | 0.00 | 0.00 | 1074.48 | 9850.30 | 3006.28 | 11439.88 | 0.00 | 955.86 | 0.00 | 0.00 | 0.00 | 0.00 | -2315.47 | -15629.87 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 1.1642 | 0.0000 | 12.7487 | 1.0000 | Calculated from schedules | 0.1023 | 1.1642 | 0.0879 | 1.0000 | Not calculated | 0.1023 | 0.0879 | ||
PSZ-FINE STORAGE | 2.7571 | 0.0000 | 30.0000 | 1.0000 | Calculated from schedules | 0.4247 | 2.7571 | 0.1540 | 1.0000 | Not calculated | 0.4247 | 0.1540 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 1.1642 | 0.0000 | 12.7487 | 1.0000 | Calculated from schedules | 0.1023 | 1.1642 | 1.0000 | 1.0000 | Not calculated | 0.1023 | 0.0879 | ||
PSZ-FINE STORAGE | 2.7571 | 0.0000 | 30.0000 | 1.0000 | Calculated from schedules | 0.4247 | 2.7571 | 1.0000 | 1.0000 | Not calculated | 0.4247 | 0.1540 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
ZONE1 OFFICE | PSZ-OFFICE | 0.000000 | 12.7487 | 0.000432 | 236.88 | 0.1023 | 1.0000 | 0.1023 | 1.000 | 0.1023 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 0.000000 | 30.0000 | 0.000305 | 1393.41 | 0.4247 | 1.0000 | 0.4247 | 1.000 | 0.4247 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-OFFICE | 0.000000 | 12.75 | 0.000432 | 236.8796 | 0.1023 | 0.1023 | 0.1023 |
PSZ-FINE STORAGE | 0.000000 | 30.00 | 0.000305 | 1393.4097 | 0.4247 | 0.4247 | 0.4247 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.1642 | 1.1642 | 1.1642 | No | 0.1023 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 2.7571 | 2.7571 | 2.7571 | No | 0.4247 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 1.1642 | 1.1642 | 1.1642 | 1.1642 | 0.1023 | 1.0000 |
PSZ-FINE STORAGE | 2.7571 | 2.7571 | 2.7571 | 2.7571 | 0.4247 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.1642 | 1.1642 | 1.1642 | No | 0.1023 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 2.7571 | 2.7571 | 2.7571 | No | 0.4247 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 1.1642 | 1.1642 | 1.1642 | 1.1642 | 0.1023 | 1.0000 |
PSZ-FINE STORAGE | 2.7571 | 2.7571 | 2.7571 | 2.7571 | 0.4247 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 |
Total gross floor area [m2] | 4835.13 |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
ZONE1 OFFICE | 236.88 | 236.88 | 0.00 | 69.73 |
ZONE2 FINE STORAGE | 1393.41 | 1393.41 | 0.00 | 69.73 |
ZONE3 BULK STORAGE | 3204.84 | 3204.84 | 0.00 | 69.73 |
Totals | 4835.13 | 4835.13 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 25.00 |
Number of hours not met | 25.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- General | 159.69 | 19529.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 139.81 | 13976.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 92.56 | 6958.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 139.29 | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- Ventilation (simple) | 29.97 | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 26.75 | 2963.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 22.10 | 1704.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 139.29 | 610.17 |
Natural Gas | 0.00 | 0.00 |
Additional | 0.00 | 0.00 |
Total | 139.29 | 610.17 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 28.92 |
Space Heating | 0.00 |
Space Cooling | 33.03 |
Fans (All) | 11.73 |
Service Water Heating | 4.57 |
Receptacle Equipment | 28.81 |
Miscellaneous (All) | 126.20 |
Subtotal | 126.20 |
Natural Gas [MJ/m2] | |
Space Heating | 0.00 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 0.00 |
Subtotal | 0.00 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 22.91 |
Space Heating | 0.00 |
Space Cooling | 26.17 |
Fans (All) | 9.30 |
Service Water Heating | 3.62 |
Receptacle Equipment | 22.83 |
Miscellaneous | 15.17 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
LTG_SCH_OFFICE | 2688. | 8760. |
LTG_SCH_BULK_STORAGE | 1777. | 8760. |
LTG_SCH_FINE_STORAGE | 1777. | 8760. |
OFFICE_PLUG_SCH | 4700. | 8760. |
BULK STORAGE PLUG SCHEDULE | 3744. | 7488. |
BLDG_OCC_SCH | 2861. | 3744. |
OFFICE PEOPLE SCHEDULE | 2861. | 3744. |
FANSCHED | 3432. | 3432. |
MINOA_MOTORIZEDDAMPER_SCHED | 3120. | 3120. |
OFFICE DHW SCHEDULE | 1825. | 5016. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 5550. | 8760. |
EXTERIOR LIGHT SCHEDULE | 5475. | 5475. |
ALWAYS OFF SCHEDULE | 0. | 0. |
OA DAMPER OFF DURING OFF HRS SCHEDULE | 2808. | 2808. |
OA DAMPER ALWAYS ON SCHEDULE | 8760. | 8760. |
MINOA_SCHED | 8760. | 8760. |
ALWAYS ON SCHEDULE | 8760. | 8760. |
EXTERIOR_LTG_SCH | 4380. | 4380. |
INFIL_DOOR_OPENING_SCH | 1154. | 3380. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 2600. | 2600. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 6935. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
BULK STORAGE HEATING SETPOINT SCHEDULE | ZONE3 BULK STORAGE HEATING SP | January | 10.00 | 365 | 10.00 | 365 |
OFFICE HEATING SCHEDULE | ZONE1 OFFICE DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
OFFICE COOLING SCHEDULE | ZONE1 OFFICE DUAL SP CONTROL | July | 23.90 | 365 | 29.40 | 365 |
FINE STORAGE HEATING SETPOINT SCHEDULE | ZONE2 FINE STORAGE DUAL SP CONTROL | January | 15.56 | 365 | 15.56 | 365 |
FINE STORAGE COOLING SETPOINT SCHEDULE | ZONE2 FINE STORAGE DUAL SP CONTROL | July | 26.70 | 365 | 26.70 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Heat Index HoursSafe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
ZONE1 OFFICE | 3465.00 | 4695.33 | 599.67 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 121.83 | 8638.17 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 10.17 | 1377.00 | 6679.33 | 693.50 | 0.00 |
Min | 10.17 | 1377.00 | 0.00 | 0.00 | 0.00 |
Max | 3465.00 | 8638.17 | 6679.33 | 693.50 | 0.00 |
Average | 1199.00 | 4903.50 | 2426.33 | 231.17 | 0.00 |
Sum | 3597.00 | 14710.50 | 7279.00 | 693.50 | 0.00 |
Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
ZONE1 OFFICE | 32688.50 | 331.33 | 7.17 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 53.00 | 82666.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 17515.00 | 141014.33 | 32663.67 | 0.00 |
Min | 0.00 | 331.33 | 0.00 | 0.00 | 0.00 |
Max | 32688.50 | 82666.00 | 141014.33 | 32663.67 | 0.00 |
Average | 10913.83 | 33504.11 | 47007.17 | 10887.89 | 0.00 |
Sum | 32741.50 | 100512.33 | 141021.50 | 32663.67 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
ZONE1 OFFICE | 2502.83 | 6095.83 | 161.33 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 1.83 | 8758.17 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 3028.50 | 5162.50 | 569.00 | 0.00 |
Min | 0.00 | 3028.50 | 0.00 | 0.00 | 0.00 |
Max | 2502.83 | 8758.17 | 5162.50 | 569.00 | 0.00 |
Average | 834.89 | 5960.83 | 1774.61 | 189.67 | 0.00 |
Sum | 2504.67 | 17882.50 | 5323.83 | 569.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
ZONE1 OFFICE | 27283.67 | 5742.17 | 1.17 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 0.00 | 82719.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 49442.50 | 114613.67 | 27136.83 | 0.00 |
Min | 0.00 | 5742.17 | 0.00 | 0.00 | 0.00 |
Max | 27283.67 | 82719.00 | 114613.67 | 27136.83 | 0.00 |
Average | 9094.56 | 45967.89 | 38204.94 | 9045.61 | 0.00 |
Sum | 27283.67 | 137903.67 | 114614.83 | 27136.83 | 0.00 |
SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
None |
SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
CO2 Level HoursSafe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:49
Illuminance Level HoursA Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
ZONE1 OFFICE | 0.00 | 0.00 | 8760.00 | 0.00 |
ZONE2 FINE STORAGE | 0.00 | 0.00 | 8760.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 8760.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 8760.00 | 8760.00 | 0.00 |
Average | 0.00 | 2920.00 | 5840.00 | 0.00 |
Sum | 0.00 | 8760.00 | 17520.00 | 0.00 |
A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
ZONE1 OFFICE | 0.00 | 0.00 | 33027.00 | 0.00 |
ZONE2 FINE STORAGE | 0.00 | 0.00 | 82719.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 191193.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 191193.00 | 82719.00 | 0.00 |
Average | 0.00 | 63731.00 | 38582.00 | 0.00 |
Sum | 0.00 | 191193.00 | 115746.00 | 0.00 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015
For: Environment
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
For: Environment
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 0A
For: Environment
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY VNM_HOCHIMINH_TANSONHOA
For: Environment
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: ZoneCoolingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.788179E+10 | 18087.14 | 24-JAN-07:03 | 19.50 | 17.57 | 0.641341E+09 | 879.39 | 20-JAN-08:09 | 19.50 | 17.57 |
February | 0.764699E+10 | 20093.91 | 23-FEB-07:01 | 22.25 | 19.97 | 0.590248E+09 | 879.39 | 10-FEB-08:09 | 22.25 | 19.97 |
March | 0.933000E+10 | 17959.19 | 04-MAR-07:02 | 24.83 | 20.47 | 0.692977E+09 | 879.39 | 15-MAR-07:10 | 24.33 | 23.37 |
April | 0.884944E+10 | 15639.94 | 27-APR-06:01 | 26.15 | 23.95 | 0.641691E+09 | 879.39 | 21-APR-07:10 | 26.15 | 23.95 |
May | 0.922031E+10 | 14943.60 | 31-MAY-06:01 | 25.22 | 25.20 | 0.667401E+09 | 879.44 | 01-MAY-07:10 | 25.22 | 25.20 |
June | 0.942694E+10 | 15013.56 | 27-JUN-06:01 | 23.42 | 23.24 | 0.667422E+09 | 879.44 | 08-JUN-07:10 | 23.42 | 23.24 |
July | 0.824825E+10 | 16920.24 | 17-JUL-06:01 | 24.45 | 23.34 | 0.641717E+09 | 879.39 | 12-JUL-07:10 | 24.45 | 23.34 |
August | 0.887809E+10 | 15156.35 | 24-AUG-06:01 | 24.25 | 24.17 | 0.693014E+09 | 879.39 | 12-AUG-07:10 | 24.25 | 24.17 |
September | 0.820387E+10 | 15790.09 | 12-SEP-06:01 | 25.10 | 24.36 | 0.641692E+09 | 879.39 | 29-SEP-07:10 | 25.42 | 24.76 |
October | 0.776663E+10 | 15496.81 | 07-OCT-06:01 | 24.68 | 24.14 | 0.641640E+09 | 879.39 | 11-OCT-07:10 | 24.92 | 24.20 |
November | 0.753874E+10 | 17874.46 | 25-NOV-07:02 | 21.17 | 18.84 | 0.615924E+09 | 879.39 | 04-NOV-07:10 | 21.17 | 18.84 |
December | 0.758345E+10 | 18120.13 | 16-DEC-07:02 | 21.33 | 20.52 | 0.641200E+09 | 879.39 | 12-DEC-08:09 | 21.33 | 20.52 |
Annual Sum or Average | 0.100575E+12 | 0.777627E+10 | ||||||||
Minimum of Months | 0.753874E+10 | 14943.60 | 19.50 | 17.57 | 0.590248E+09 | 879.39 | 19.50 | 17.57 | ||
Maximum of Months | 0.942694E+10 | 20093.91 | 26.15 | 25.20 | 0.693014E+09 | 879.44 | 26.15 | 25.20 |
Report: ZoneCoolingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.173846E+11 | 53331.80 | 16-JAN-16:53 | 29.00 | 22.07 | 0.185458E+10 | 2246.96 | 12-JAN-15:00 | 29.00 | 22.07 |
February | 0.188719E+11 | 51461.39 | 20-FEB-15:02 | 33.02 | 24.28 | 0.170654E+10 | 2246.98 | 28-FEB-14:50 | 35.00 | 24.83 |
March | 0.240259E+11 | 51605.56 | 12-MAR-14:43 | 32.17 | 24.72 | 0.200319E+10 | 2247.03 | 21-MAR-13:00 | 36.00 | 23.97 |
April | 0.246718E+11 | 49780.57 | 23-APR-13:53 | 33.00 | 24.68 | 0.185478E+10 | 2247.01 | 26-APR-14:09 | 34.70 | 26.09 |
May | 0.242837E+11 | 46694.65 | 29-MAY-14:13 | 33.33 | 27.76 | 0.192891E+10 | 2246.99 | 09-MAY-15:39 | 33.33 | 27.76 |
June | 0.254650E+11 | 45066.20 | 30-JUN-06:01 | 24.87 | 24.85 | 0.192890E+10 | 2247.00 | 27-JUN-13:00 | 24.87 | 24.85 |
July | 0.203008E+11 | 50858.76 | 16-JUL-14:53 | 25.50 | 24.07 | 0.185480E+10 | 2246.95 | 01-JUL-14:50 | 25.50 | 24.07 |
August | 0.199787E+11 | 46286.78 | 27-AUG-15:32 | 32.67 | 25.69 | 0.200319E+10 | 2246.99 | 15-AUG-12:39 | 32.67 | 25.69 |
September | 0.197534E+11 | 48429.09 | 10-SEP-13:43 | 33.75 | 26.37 | 0.185476E+10 | 2247.00 | 05-SEP-13:20 | 33.75 | 26.37 |
October | 0.170008E+11 | 46612.50 | 08-OCT-16:23 | 29.55 | 25.01 | 0.185491E+10 | 2246.95 | 27-OCT-13:00 | 29.50 | 25.84 |
November | 0.164254E+11 | 49816.82 | 05-NOV-15:13 | 30.23 | 24.64 | 0.178059E+10 | 2246.96 | 06-NOV-13:09 | 30.50 | 24.94 |
December | 0.160111E+11 | 52307.08 | 03-DEC-15:43 | 29.75 | 22.28 | 0.185432E+10 | 2246.95 | 26-DEC-16:30 | 29.60 | 22.58 |
Annual Sum or Average | 0.244173E+12 | 0.224795E+11 | ||||||||
Minimum of Months | 0.160111E+11 | 45066.20 | 24.87 | 22.07 | 0.170654E+10 | 2246.95 | 24.87 | 22.07 | ||
Maximum of Months | 0.254650E+11 | 53331.80 | 33.75 | 27.76 | 0.200319E+10 | 2247.03 | 36.00 | 27.76 |
Report: ZoneCoolingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 | 23.60 | 0.543757E+10 | 7930.09 | 05-JAN-15:09 | 33.73 | 23.23 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 | 22.46 | 0.524397E+10 | 8492.03 | 28-FEB-15:09 | 34.60 | 24.66 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 25.93 | 22.97 | 0.635632E+10 | 9021.06 | 21-MAR-13:30 | 36.20 | 23.50 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 | 25.10 | 0.594610E+10 | 8694.92 | 01-APR-14:20 | 35.33 | 26.89 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 | 26.40 | 0.619104E+10 | 9097.65 | 05-MAY-12:09 | 36.90 | 26.19 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 | 23.91 | 0.621766E+10 | 9005.69 | 16-JUN-14:09 | 35.33 | 27.51 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 | 24.33 | 0.545693E+10 | 7810.28 | 15-JUL-15:00 | 33.20 | 25.63 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 | 24.75 | 0.598119E+10 | 8065.47 | 10-AUG-14:09 | 33.50 | 27.78 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 26.53 | 25.66 | 0.554707E+10 | 8122.38 | 06-SEP-14:20 | 33.67 | 26.68 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 | 25.35 | 0.535678E+10 | 7725.69 | 04-OCT-14:20 | 32.83 | 26.21 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 | 24.37 | 0.516458E+10 | 7973.89 | 18-NOV-13:20 | 33.20 | 25.24 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 | 23.43 | 0.537872E+10 | 7748.35 | 08-DEC-14:50 | 33.00 | 23.58 |
Annual Sum or Average | 0.00 | 0.682779E+11 | ||||||||
Minimum of Months | 0.00 | 0.00 | 23.80 | 22.46 | 0.516458E+10 | 7725.69 | 32.83 | 23.23 | ||
Maximum of Months | 0.00 | 0.00 | 28.62 | 26.40 | 0.635632E+10 | 9097.65 | 36.90 | 27.78 |
Report: ZoneHeatingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 4240088.03 | 737.93 | 11-JAN-07:06 | 25.55 |
February | 4687846.82 | 868.55 | 18-FEB-07:06 | 26.42 |
March | 6697313.41 | 844.88 | 09-MAR-07:06 | 26.50 |
April | 5336172.12 | 856.09 | 01-APR-06:20 | 26.87 |
May | 3331209.32 | 834.67 | 13-MAY-06:20 | 26.93 |
June | 2986261.03 | 801.86 | 24-JUN-06:20 | 26.77 |
July | 5450248.14 | 764.76 | 15-JUL-06:06 | 25.77 |
August | 4988678.06 | 792.37 | 26-AUG-06:20 | 26.33 |
September | 5325180.30 | 813.67 | 02-SEP-06:17 | 26.47 |
October | 5181347.09 | 743.35 | 05-OCT-06:07 | 26.67 |
November | 4963555.01 | 766.93 | 07-NOV-07:06 | 25.75 |
December | 4421452.37 | 699.34 | 09-DEC-07:06 | 25.25 |
Annual Sum or Average | 57609351.71 | |||
Minimum of Months | 2986261.03 | 699.34 | 25.25 | |
Maximum of Months | 6697313.41 | 868.55 | 26.93 |
Report: ZoneHeatingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 534968.27 | 1126.00 | 11-JAN-07:03 | 25.55 |
February | 370006.39 | 1460.69 | 18-FEB-07:03 | 26.42 |
March | 1810859.22 | 1690.54 | 28-MAR-06:03 | 27.03 |
April | 2569721.97 | 1891.09 | 11-APR-06:03 | 27.20 |
May | 2144830.12 | 2127.68 | 05-MAY-06:03 | 28.23 |
June | 1721622.68 | 1691.15 | 14-JUN-06:03 | 27.28 |
July | 959057.43 | 937.11 | 26-JUL-06:03 | 25.17 |
August | 1768387.92 | 1321.48 | 25-AUG-06:03 | 26.17 |
September | 1547627.91 | 1419.85 | 01-SEP-06:03 | 26.33 |
October | 1028103.13 | 1030.60 | 20-OCT-06:03 | 25.85 |
November | 971330.26 | 1241.22 | 13-NOV-07:02 | 26.08 |
December | 174898.34 | 859.50 | 09-DEC-07:03 | 25.25 |
Annual Sum or Average | 15601413.63 | |||
Minimum of Months | 174898.34 | 859.50 | 25.17 | |
Maximum of Months | 2569721.97 | 2127.68 | 28.23 |
Report: ZoneHeatingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneElectricSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.154297E+10 | 1230.12 | 02-JAN-16:00 | 0.267964E+10 | 1912.50 | 02-JAN-08:09 |
February | 0.139588E+10 | 1205.28 | 08-FEB-08:09 | 0.243949E+10 | 1912.50 | 01-FEB-08:09 |
March | 0.158695E+10 | 1226.71 | 28-MAR-07:10 | 0.277107E+10 | 1912.50 | 01-MAR-08:09 |
April | 0.149248E+10 | 1225.39 | 21-APR-07:10 | 0.263007E+10 | 1912.50 | 01-APR-07:10 |
May | 0.154917E+10 | 1231.40 | 17-MAY-07:10 | 0.272536E+10 | 1912.50 | 01-MAY-07:10 |
June | 0.150426E+10 | 1222.84 | 20-JUN-07:10 | 0.267579E+10 | 1912.50 | 01-JUN-07:10 |
July | 0.151952E+10 | 1225.64 | 11-JUL-07:10 | 0.267964E+10 | 1912.50 | 01-JUL-07:10 |
August | 0.158095E+10 | 1229.00 | 21-AUG-07:10 | 0.277107E+10 | 1912.50 | 01-AUG-07:10 |
September | 0.151325E+10 | 1229.43 | 21-SEP-07:10 | 0.263007E+10 | 1912.50 | 01-SEP-07:10 |
October | 0.154339E+10 | 1240.14 | 23-OCT-07:10 | 0.267964E+10 | 1912.50 | 02-OCT-07:10 |
November | 0.149073E+10 | 1246.70 | 27-NOV-16:00 | 0.258435E+10 | 1912.50 | 01-NOV-07:10 |
December | 0.155208E+10 | 1262.55 | 18-DEC-16:49 | 0.267964E+10 | 1912.50 | 01-DEC-08:09 |
Annual Sum or Average | 0.182716E+11 | 0.319458E+11 | ||||
Minimum of Months | 0.139588E+10 | 1205.28 | 0.243949E+10 | 1912.50 | ||
Maximum of Months | 0.158695E+10 | 1262.55 | 0.277107E+10 | 1912.50 |
Report: ZoneElectricSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
January | 0.451780E+10 | 5289.79 | 02-JAN-16:49 | 0.00 | 0.00 |
February | 0.406192E+10 | 4848.97 | 01-FEB-16:00 | 0.00 | 0.00 |
March | 0.462199E+10 | 4848.97 | 01-MAR-16:49 | 0.00 | 0.00 |
April | 0.432488E+10 | 4496.32 | 01-APR-08:09 | 0.00 | 0.00 |
May | 0.450193E+10 | 4848.97 | 17-MAY-07:10 | 0.00 | 0.00 |
June | 0.446481E+10 | 4408.16 | 01-JUN-07:10 | 0.00 | 0.00 |
July | 0.439636E+10 | 4848.97 | 11-JUL-07:10 | 0.00 | 0.00 |
August | 0.458408E+10 | 4496.32 | 01-AUG-08:09 | 0.00 | 0.00 |
September | 0.431976E+10 | 4408.16 | 01-SEP-07:10 | 0.00 | 0.00 |
October | 0.440629E+10 | 4848.97 | 23-OCT-07:10 | 0.00 | 0.00 |
November | 0.433431E+10 | 5289.79 | 06-NOV-16:49 | 0.00 | 0.00 |
December | 0.456071E+10 | 5495.50 | 18-DEC-15:00 | 0.00 | 0.00 |
Annual Sum or Average | 0.530948E+11 | 0.00 | 0.00 | ||
Minimum of Months | 0.406192E+10 | 4408.16 | 0.00 | 0.00 | |
Maximum of Months | 0.462199E+10 | 5495.50 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.588140E+10 | 6808.98 | 02-JAN-16:00 | 0.885613E+10 | 8200.12 | 02-JAN-08:09 |
February | 0.530169E+10 | 5942.38 | 01-FEB-17:19 | 0.814764E+10 | 8200.12 | 01-FEB-08:09 |
March | 0.598339E+10 | 5942.38 | 01-MAR-17:19 | 0.957200E+10 | 8200.12 | 01-MAR-08:09 |
April | 0.553649E+10 | 5942.38 | 05-APR-06:10 | 0.885613E+10 | 8200.12 | 01-APR-07:10 |
May | 0.572098E+10 | 5447.18 | 09-MAY-06:10 | 0.921037E+10 | 8200.12 | 01-MAY-07:10 |
June | 0.563437E+10 | 5942.38 | 20-JUN-06:10 | 0.921037E+10 | 8200.12 | 01-JUN-07:10 |
July | 0.559198E+10 | 5942.38 | 07-JUL-06:10 | 0.885613E+10 | 8200.12 | 01-JUL-07:10 |
August | 0.588526E+10 | 5942.38 | 02-AUG-06:10 | 0.956462E+10 | 8200.12 | 01-AUG-07:10 |
September | 0.557725E+10 | 5942.38 | 07-SEP-06:10 | 0.884875E+10 | 8200.12 | 01-SEP-07:10 |
October | 0.570880E+10 | 5942.38 | 14-OCT-06:10 | 0.886351E+10 | 8200.12 | 02-OCT-07:10 |
November | 0.567453E+10 | 7427.98 | 09-NOV-16:00 | 0.850188E+10 | 8200.12 | 01-NOV-07:10 |
December | 0.594818E+10 | 7427.98 | 04-DEC-16:00 | 0.885613E+10 | 8200.12 | 01-DEC-08:09 |
Annual Sum or Average | 0.684443E+11 | 0.107344E+12 | ||||
Minimum of Months | 0.530169E+10 | 5447.18 | 0.814764E+10 | 8200.12 | ||
Maximum of Months | 0.598339E+10 | 7427.98 | 0.957200E+10 | 8200.12 |
Report: SpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.138726E+10 | 0.154297E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.595007E+09 | 0.197011E+09 |
February | 0.127628E+10 | 0.139588E+10 | 0.243949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.659565E+09 | 0.118335E+09 |
March | 0.149825E+10 | 0.158695E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.919142E+09 | 0.133919E+09 |
April | 0.138726E+10 | 0.149248E+10 | 0.263007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.847874E+09 | 53009171.89 |
May | 0.144276E+10 | 0.154917E+10 | 0.272536E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.930746E+09 | 73345063.26 |
June | 0.144276E+10 | 0.150426E+10 | 0.267579E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.939528E+09 | 82176838.10 |
July | 0.138726E+10 | 0.151952E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.566580E+09 | 93388942.95 |
August | 0.149825E+10 | 0.158095E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.731980E+09 | 0.121146E+09 |
September | 0.138726E+10 | 0.151325E+10 | 0.263007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.597886E+09 | 79598253.83 |
October | 0.138726E+10 | 0.154339E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.516042E+09 | 0.112160E+09 |
November | 0.133177E+10 | 0.149073E+10 | 0.258435E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.523256E+09 | 0.112864E+09 |
December | 0.138726E+10 | 0.155208E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.489653E+09 | 0.194696E+09 |
Annual Sum or Average | 0.168137E+11 | 0.182716E+11 | 0.319458E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.831726E+10 | 0.137165E+10 |
Minimum of Months | 0.127628E+10 | 0.139588E+10 | 0.243949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.489653E+09 | 53009171.89 |
Maximum of Months | 0.149825E+10 | 0.158695E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.939528E+09 | 0.197011E+09 |
Report: SpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.326447E+10 | 0.451780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.436276E+09 | 0.533305E+09 |
February | 0.300332E+10 | 0.406192E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.712092E+09 | 0.206994E+09 |
March | 0.352563E+10 | 0.462199E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121146E+10 | 0.308100E+09 |
April | 0.326447E+10 | 0.432488E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123287E+10 | 64051616.62 |
May | 0.339505E+10 | 0.450193E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142275E+10 | 0.157331E+09 |
June | 0.339505E+10 | 0.446481E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129815E+10 | 0.142455E+09 |
July | 0.326447E+10 | 0.439636E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.702563E+09 | 0.187199E+09 |
August | 0.352563E+10 | 0.458408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.798754E+09 | 0.346029E+09 |
September | 0.326447E+10 | 0.431976E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.615892E+09 | 0.201034E+09 |
October | 0.326447E+10 | 0.440629E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.434565E+09 | 0.309984E+09 |
November | 0.313390E+10 | 0.433431E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.324552E+09 | 0.343768E+09 |
December | 0.326447E+10 | 0.456071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.300425E+09 | 0.600626E+09 |
Annual Sum or Average | 0.395654E+11 | 0.530948E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.949035E+10 | 0.340088E+10 |
Minimum of Months | 0.300332E+10 | 0.406192E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.300425E+09 | 64051616.62 |
Maximum of Months | 0.352563E+10 | 0.462199E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142275E+10 | 0.600626E+09 |
Report: SpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.750829E+10 | 0.588140E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.179523E+09 | 0.535982E+10 |
February | 0.690763E+10 | 0.530169E+10 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101671E+09 | 0.342457E+10 |
March | 0.810895E+10 | 0.598339E+10 | 0.957200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.185881E+09 | 0.584906E+10 |
April | 0.750829E+10 | 0.553649E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123649E+09 | 0.291856E+10 |
May | 0.780862E+10 | 0.572098E+10 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.291865E+09 | 0.367496E+10 |
June | 0.780862E+10 | 0.563437E+10 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182211E+09 | 0.354092E+10 |
July | 0.750829E+10 | 0.559198E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33546286.01 | 0.342222E+10 |
August | 0.810895E+10 | 0.588526E+10 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 98025566.21 | 0.578711E+10 |
September | 0.750829E+10 | 0.557725E+10 | 0.884875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41045651.55 | 0.351987E+10 |
October | 0.750829E+10 | 0.570880E+10 | 0.886351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15719597.11 | 0.441668E+10 |
November | 0.720796E+10 | 0.567453E+10 | 0.850188E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12087272.36 | 0.430896E+10 |
December | 0.750829E+10 | 0.594818E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19078789.52 | 0.575173E+10 |
Annual Sum or Average | 0.910005E+11 | 0.684443E+11 | 0.107344E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128430E+10 | 0.519745E+11 |
Minimum of Months | 0.690763E+10 | 0.530169E+10 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12087272.36 | 0.291856E+10 |
Maximum of Months | 0.810895E+10 | 0.598339E+10 | 0.957200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.291865E+09 | 0.584906E+10 |
Report: PeakSpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1680.92 | 02-JAN-08:09 | 1230.12 | 02-JAN-16:00 | 1912.50 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3687.33 | 04-JAN-13:00 | 2464.89 | 23-JAN-07:02 |
February | 1680.92 | 01-FEB-08:09 | 1205.28 | 08-FEB-08:09 | 1912.50 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3752.94 | 28-FEB-13:00 | 2131.76 | 01-FEB-07:02 |
March | 1680.92 | 01-MAR-08:09 | 1226.71 | 28-MAR-07:10 | 1912.50 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4050.73 | 20-MAR-16:10 | 1445.73 | 15-MAR-06:02 |
April | 1680.92 | 01-APR-07:10 | 1225.39 | 21-APR-07:10 | 1912.50 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4167.79 | 11-APR-16:10 | 1055.89 | 24-APR-06:01 |
May | 1680.92 | 01-MAY-07:10 | 1231.40 | 17-MAY-07:10 | 1912.50 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4692.74 | 05-MAY-16:10 | 1357.35 | 17-MAY-06:01 |
June | 1680.92 | 01-JUN-07:10 | 1222.84 | 20-JUN-07:10 | 1912.50 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4359.39 | 13-JUN-16:10 | 1541.91 | 21-JUN-06:01 |
July | 1680.92 | 01-JUL-07:10 | 1225.64 | 11-JUL-07:10 | 1912.50 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3560.50 | 26-JUL-17:00 | 1211.70 | 31-JUL-06:01 |
August | 1680.92 | 01-AUG-07:10 | 1229.00 | 21-AUG-07:10 | 1912.50 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3595.15 | 09-AUG-16:10 | 1247.84 | 04-AUG-06:01 |
September | 1680.92 | 01-SEP-07:10 | 1229.43 | 21-SEP-07:10 | 1912.50 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3202.14 | 12-SEP-12:00 | 1247.63 | 18-SEP-06:01 |
October | 1680.92 | 02-OCT-07:10 | 1240.14 | 23-OCT-07:10 | 1912.50 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3080.66 | 04-OCT-12:00 | 1598.05 | 23-OCT-06:01 |
November | 1680.92 | 01-NOV-07:10 | 1246.70 | 27-NOV-16:00 | 1912.50 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2899.83 | 10-NOV-12:10 | 1803.35 | 27-NOV-07:02 |
December | 1680.92 | 01-DEC-08:09 | 1262.55 | 18-DEC-16:49 | 1912.50 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2878.14 | 26-DEC-13:00 | 2709.38 | 21-DEC-07:03 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1680.92 | 1205.28 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 2878.14 | 1055.89 | |||||
Maximum of Months | 1680.92 | 1262.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 4692.74 | 2709.38 |
Report: PeakSpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 3955.50 | 02-JAN-08:09 | 5289.79 | 02-JAN-16:49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2057.22 | 31-JAN-16:10 | 5108.77 | 07-JAN-05:00 |
February | 3955.50 | 01-FEB-08:09 | 4848.97 | 01-FEB-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3181.99 | 28-FEB-16:10 | 1411.67 | 01-FEB-07:02 |
March | 3955.50 | 01-MAR-08:09 | 4848.97 | 01-MAR-16:49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4818.83 | 19-MAR-15:58 | 1166.95 | 14-MAR-21:40 |
April | 3955.50 | 01-APR-07:10 | 4496.32 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3303.96 | 11-APR-16:00 | 1001.53 | 14-APR-16:00 |
May | 3955.50 | 01-MAY-07:10 | 4848.97 | 17-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5657.62 | 06-MAY-15:10 | 1855.12 | 08-MAY-22:00 |
June | 3955.50 | 01-JUN-07:10 | 4408.16 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4531.04 | 16-JUN-15:30 | 2038.10 | 20-JUN-23:00 |
July | 3955.50 | 01-JUL-07:10 | 4848.97 | 11-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2779.66 | 13-JUL-16:00 | 1482.76 | 19-JUL-19:00 |
August | 3955.50 | 01-AUG-07:10 | 4496.32 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3174.55 | 09-AUG-16:00 | 1838.20 | 23-AUG-19:55 |
September | 3955.50 | 01-SEP-07:10 | 4408.16 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2999.45 | 10-SEP-14:52 | 2921.37 | 15-SEP-17:00 |
October | 3955.50 | 02-OCT-07:10 | 4848.97 | 23-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2807.72 | 29-OCT-13:00 | 1322.12 | 30-OCT-16:20 |
November | 3955.50 | 01-NOV-07:10 | 5289.79 | 06-NOV-16:49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1462.36 | 04-NOV-15:10 | 1242.39 | 25-NOV-08:00 |
December | 3955.50 | 01-DEC-08:09 | 5495.50 | 18-DEC-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1321.93 | 13-DEC-16:10 | 1913.25 | 21-DEC-07:03 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 3955.50 | 4408.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1321.93 | 1001.53 | ||||
Maximum of Months | 3955.50 | 5495.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5657.62 | 5108.77 |
Report: PeakSpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 9097.65 | 02-JAN-08:09 | 6808.98 | 02-JAN-16:00 | 8200.12 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5378.41 | 03-JAN-11:50 | 34424.08 | 07-JAN-05:00 |
February | 9097.65 | 01-FEB-08:09 | 5942.38 | 01-FEB-17:19 | 8200.12 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1597.14 | 28-FEB-13:10 | 8220.60 | 01-FEB-08:10 |
March | 9097.65 | 01-MAR-08:09 | 5942.38 | 01-MAR-17:19 | 8200.12 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3175.44 | 19-MAR-11:53 | 9275.52 | 14-MAR-22:00 |
April | 9097.65 | 01-APR-07:10 | 5942.38 | 05-APR-06:10 | 8200.12 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1804.34 | 17-APR-09:43 | 8039.27 | 14-APR-15:52 |
May | 9097.65 | 01-MAY-07:10 | 5447.18 | 09-MAY-06:10 | 8200.12 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4630.19 | 01-MAY-13:53 | 15428.73 | 08-MAY-22:00 |
June | 9097.65 | 01-JUN-07:10 | 5942.38 | 20-JUN-06:10 | 8200.12 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2045.79 | 18-JUN-13:43 | 17032.61 | 20-JUN-23:00 |
July | 9097.65 | 01-JUL-07:10 | 5942.38 | 07-JUL-06:10 | 8200.12 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1240.87 | 31-JUL-12:45 | 17282.85 | 03-JUL-13:00 |
August | 9097.65 | 01-AUG-07:10 | 5942.38 | 02-AUG-06:10 | 8200.12 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1920.49 | 05-AUG-13:55 | 21274.62 | 25-AUG-11:00 |
September | 9097.65 | 01-SEP-07:10 | 5942.38 | 07-SEP-06:10 | 8200.12 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1882.32 | 22-SEP-15:55 | 18315.46 | 15-SEP-16:52 |
October | 9097.65 | 02-OCT-07:10 | 5942.38 | 14-OCT-06:10 | 8200.12 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1322.02 | 06-OCT-10:55 | 13714.50 | 11-OCT-13:10 |
November | 9097.65 | 01-NOV-07:10 | 7427.98 | 09-NOV-16:00 | 8200.12 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1176.63 | 18-NOV-12:55 | 8730.49 | 25-NOV-08:10 |
December | 9097.65 | 01-DEC-08:09 | 7427.98 | 04-DEC-16:00 | 8200.12 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 778.65 | 14-DEC-12:55 | 12875.86 | 20-DEC-09:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 9097.65 | 5447.18 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 778.65 | 8039.27 | |||||
Maximum of Months | 9097.65 | 7427.98 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 5378.41 | 34424.08 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 18087.14 | 24-JAN-07:03 | 1411.97 | 2694.92 | 3825.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2290.85 |
February | 20093.91 | 23-FEB-07:01 | 2470.96 | 4676.51 | 6693.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1835.79 |
March | 17959.19 | 04-MAR-07:02 | 2117.96 | 3982.90 | 5737.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 127.65 |
April | 15639.94 | 27-APR-06:01 | 2470.96 | 4721.78 | 6693.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 489.35 |
May | 14943.60 | 31-MAY-06:01 | 2470.96 | 4746.11 | 6693.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 904.95 |
June | 15013.56 | 27-JUN-06:01 | 2470.96 | 4703.39 | 6693.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1513.75 |
July | 16920.24 | 17-JUL-06:01 | 2823.95 | 5409.56 | 7650.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1169.63 |
August | 15156.35 | 24-AUG-06:01 | 2470.96 | 4859.60 | 6693.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1140.53 |
September | 15790.09 | 12-SEP-06:01 | 2470.96 | 4754.58 | 6693.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 884.15 |
October | 15496.81 | 07-OCT-06:01 | 2470.96 | 4759.47 | 6693.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76.24 |
November | 17874.46 | 25-NOV-07:02 | 2117.96 | 3985.59 | 5737.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 186.35 |
December | 18120.13 | 16-DEC-07:02 | 2117.96 | 4012.30 | 5737.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 79.16 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 14943.60 | 1411.97 | 2694.92 | 3825.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76.24 | |
Maximum of Months | 20093.91 | 2823.95 | 5409.56 | 7650.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2290.85 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 53331.80 | 16-JAN-16:53 | 0.00 | 2115.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 725.20 | 0.00 |
February | 51461.39 | 20-FEB-15:02 | 0.00 | 1410.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 956.85 | 0.00 |
March | 51605.56 | 12-MAR-14:43 | 0.00 | 1410.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 537.24 | 0.00 |
April | 49780.57 | 23-APR-13:53 | 0.00 | 1410.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1384.29 | 0.00 |
May | 46694.65 | 29-MAY-14:13 | 0.00 | 1410.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 363.51 | 0.00 |
June | 45066.20 | 30-JUN-06:01 | 5814.59 | 29622.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 258.81 |
July | 50858.76 | 16-JUL-14:53 | 0.00 | 1234.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 151.61 |
August | 46286.78 | 27-AUG-15:32 | 0.00 | 1645.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1595.50 | 0.00 |
September | 48429.09 | 10-SEP-13:43 | 0.00 | 1410.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 785.97 | 0.00 |
October | 46612.50 | 08-OCT-16:23 | 0.00 | 1763.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 722.84 | 0.00 |
November | 49816.82 | 05-NOV-15:13 | 0.00 | 1234.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 434.37 | 0.00 |
December | 52307.08 | 03-DEC-15:43 | 0.00 | 1586.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 560.95 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 45066.20 | 0.00 | 1234.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 53331.80 | 5814.59 | 29622.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1595.50 | 258.81 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 990.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 377.58 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 990.40 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2552.04 |
March | 0.00 | 01-MAR-00:03 | 0.00 | 2971.19 | 6150.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3212.79 |
April | 0.00 | 01-APR-00:10 | 0.00 | 990.40 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3220.61 |
May | 0.00 | 01-MAY-00:05 | 0.00 | 1980.79 | 4100.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1222.17 |
June | 0.00 | 01-JUN-00:10 | 0.00 | 990.40 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3546.18 |
July | 0.00 | 01-JUL-00:10 | 0.00 | 990.40 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2757.45 |
August | 0.00 | 01-AUG-00:10 | 0.00 | 990.40 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3976.41 |
September | 0.00 | 01-SEP-00:03 | 0.00 | 2971.19 | 6150.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2169.51 |
October | 0.00 | 01-OCT-00:10 | 0.00 | 990.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1048.42 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 990.40 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1483.39 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 990.40 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2107.41 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 990.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 377.58 | |
Maximum of Months | 0.00 | 0.00 | 2971.19 | 6150.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3976.41 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
January | 0.479975E+11 | 38736.88 | 05-JAN-16:00 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 0.456866E+11 | 39053.76 | 28-FEB-14:50 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 0.541629E+11 | 39855.54 | 27-MAR-13:50 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 0.536401E+11 | 41166.86 | 11-APR-15:00 | 0.00 | 0.00 | 01-APR-00:10 |
May | 0.562293E+11 | 44160.05 | 06-MAY-15:09 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 0.560860E+11 | 43864.38 | 13-JUN-14:50 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 0.494308E+11 | 37972.88 | 19-JUL-14:00 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 0.531125E+11 | 40463.39 | 11-AUG-14:20 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 0.502571E+11 | 39743.61 | 06-SEP-14:20 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 0.489886E+11 | 39142.26 | 04-OCT-15:39 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 0.469808E+11 | 39368.85 | 10-NOV-16:00 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 0.475975E+11 | 39038.65 | 13-DEC-16:49 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.610170E+12 | 0.00 | ||||
Minimum of Months | 0.456866E+11 | 37972.88 | 0.00 | 0.00 | ||
Maximum of Months | 0.562293E+11 | 44160.05 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.119422E+11 | 0.831046E+10 | 0.115358E+11 | 0.00 | 0.380307E+10 | 0.00 | 0.00 | 0.105205E+11 | 0.00 | 0.00 | 0.00 | 0.188555E+10 | 0.00 |
February | 0.107595E+11 | 0.736872E+10 | 0.105871E+11 | 0.00 | 0.418749E+10 | 0.00 | 0.00 | 0.110755E+11 | 0.00 | 0.00 | 0.00 | 0.170830E+10 | 0.00 |
March | 0.121923E+11 | 0.786374E+10 | 0.123431E+11 | 0.00 | 0.528815E+10 | 0.00 | 0.00 | 0.145629E+11 | 0.00 | 0.00 | 0.00 | 0.191273E+10 | 0.00 |
April | 0.113538E+11 | 0.739675E+10 | 0.114862E+11 | 0.00 | 0.593845E+10 | 0.00 | 0.00 | 0.156475E+11 | 0.00 | 0.00 | 0.00 | 0.181737E+10 | 0.00 |
May | 0.117721E+11 | 0.748800E+10 | 0.119357E+11 | 0.00 | 0.622472E+10 | 0.00 | 0.00 | 0.169380E+11 | 0.00 | 0.00 | 0.00 | 0.187081E+10 | 0.00 |
June | 0.116034E+11 | 0.714625E+10 | 0.118862E+11 | 0.00 | 0.612509E+10 | 0.00 | 0.00 | 0.175084E+11 | 0.00 | 0.00 | 0.00 | 0.181671E+10 | 0.00 |
July | 0.115079E+11 | 0.745460E+10 | 0.115358E+11 | 0.00 | 0.442087E+10 | 0.00 | 0.00 | 0.126699E+11 | 0.00 | 0.00 | 0.00 | 0.184174E+10 | 0.00 |
August | 0.120503E+11 | 0.756732E+10 | 0.123357E+11 | 0.00 | 0.471058E+10 | 0.00 | 0.00 | 0.145673E+11 | 0.00 | 0.00 | 0.00 | 0.188134E+10 | 0.00 |
September | 0.114103E+11 | 0.754705E+10 | 0.114788E+11 | 0.00 | 0.456199E+10 | 0.00 | 0.00 | 0.134499E+11 | 0.00 | 0.00 | 0.00 | 0.180911E+10 | 0.00 |
October | 0.116585E+11 | 0.803909E+10 | 0.115432E+11 | 0.00 | 0.402637E+10 | 0.00 | 0.00 | 0.118565E+11 | 0.00 | 0.00 | 0.00 | 0.186505E+10 | 0.00 |
November | 0.114996E+11 | 0.800072E+10 | 0.110862E+11 | 0.00 | 0.374646E+10 | 0.00 | 0.00 | 0.108363E+11 | 0.00 | 0.00 | 0.00 | 0.181149E+10 | 0.00 |
December | 0.120610E+11 | 0.837438E+10 | 0.115358E+11 | 0.00 | 0.368526E+10 | 0.00 | 0.00 | 0.100571E+11 | 0.00 | 0.00 | 0.00 | 0.188399E+10 | 0.00 |
Annual Sum or Average | 0.139811E+12 | 0.925571E+11 | 0.139290E+12 | 0.00 | 0.567185E+11 | 0.00 | 0.00 | 0.159690E+12 | 0.00 | 0.00 | 0.00 | 0.221042E+11 | 0.00 |
Minimum of Months | 0.107595E+11 | 0.714625E+10 | 0.105871E+11 | 0.00 | 0.368526E+10 | 0.00 | 0.00 | 0.100571E+11 | 0.00 | 0.00 | 0.00 | 0.170830E+10 | 0.00 |
Maximum of Months | 0.121923E+11 | 0.837438E+10 | 0.123431E+11 | 0.00 | 0.622472E+10 | 0.00 | 0.00 | 0.175084E+11 | 0.00 | 0.00 | 0.00 | 0.191273E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 13328.89 | 02-JAN-16:00 | 6958.21 | 01-JAN-06:10 | 10112.62 | 02-JAN-08:09 | 0.00 | 4501.40 | 11-JAN-08:09 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 11455.13 | 01-FEB-16:00 | 6958.21 | 01-FEB-06:10 | 10112.62 | 01-FEB-08:09 | 0.00 | 4480.55 | 15-FEB-12:00 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 11598.38 | 01-MAR-16:00 | 6958.21 | 01-MAR-06:10 | 10112.62 | 01-MAR-08:09 | 0.00 | 4706.60 | 20-MAR-15:09 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 10869.83 | 21-APR-06:10 | 6958.21 | 01-APR-05:10 | 10112.62 | 01-APR-07:10 | 0.00 | 4769.29 | 11-APR-15:00 | 0.00 | 0.00 | 01-APR-00:10 |
May | 11032.36 | 17-MAY-07:10 | 6958.21 | 01-MAY-05:10 | 10112.62 | 01-MAY-07:10 | 0.00 | 5268.55 | 06-MAY-15:09 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 10869.12 | 20-JUN-06:10 | 6958.21 | 01-JUN-05:10 | 10112.62 | 01-JUN-07:10 | 0.00 | 5223.45 | 13-JUN-15:09 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 11026.60 | 11-JUL-07:10 | 6958.21 | 01-JUL-05:10 | 10112.62 | 01-JUL-07:10 | 0.00 | 4409.03 | 24-JUL-11:00 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 10868.44 | 24-AUG-06:10 | 6958.21 | 01-AUG-05:10 | 10112.62 | 01-AUG-07:10 | 0.00 | 4778.46 | 11-AUG-11:00 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 10869.49 | 21-SEP-06:10 | 6958.21 | 01-SEP-05:10 | 10112.62 | 01-SEP-07:10 | 0.00 | 4650.22 | 06-SEP-11:00 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 11199.24 | 30-OCT-15:00 | 6958.21 | 01-OCT-05:10 | 10112.62 | 02-OCT-07:10 | 0.00 | 4487.55 | 04-OCT-11:00 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 13964.47 | 27-NOV-16:00 | 6958.21 | 01-NOV-05:10 | 10112.62 | 01-NOV-07:10 | 0.00 | 4434.15 | 13-NOV-12:00 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 13976.97 | 18-DEC-16:00 | 6958.21 | 01-DEC-17:30 | 10112.62 | 01-DEC-08:09 | 0.00 | 4416.22 | 11-DEC-12:00 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||||
Minimum of Months | 10868.44 | 6958.21 | 10112.62 | 0.00 | 4409.03 | 0.00 | 0.00 | |||||
Maximum of Months | 13976.97 | 6958.21 | 10112.62 | 0.00 | 5268.55 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 13614.53 | 04-JAN-12:00 | 0.00 | 0.00 | 0.00 | 1704.69 | 11-JAN-12:30 | 0.00 |
February | 14707.11 | 15-FEB-12:00 | 0.00 | 0.00 | 0.00 | 1704.10 | 01-FEB-12:39 | 0.00 |
March | 15871.98 | 20-MAR-15:09 | 0.00 | 0.00 | 0.00 | 1701.74 | 01-MAR-12:30 | 0.00 |
April | 16466.44 | 11-APR-15:00 | 0.00 | 0.00 | 0.00 | 1697.74 | 01-APR-11:20 | 0.00 |
May | 19529.61 | 06-MAY-15:09 | 0.00 | 0.00 | 0.00 | 1693.33 | 01-MAY-11:30 | 0.00 |
June | 19227.47 | 13-JUN-15:09 | 0.00 | 0.00 | 0.00 | 1689.50 | 01-JUN-11:09 | 0.00 |
July | 13645.67 | 26-JUL-15:09 | 0.00 | 0.00 | 0.00 | 1687.61 | 31-JUL-11:50 | 0.00 |
August | 16392.80 | 11-AUG-11:00 | 0.00 | 0.00 | 0.00 | 1690.05 | 31-AUG-11:09 | 0.00 |
September | 15602.76 | 06-SEP-11:00 | 0.00 | 0.00 | 0.00 | 1693.97 | 30-SEP-11:20 | 0.00 |
October | 14716.97 | 04-OCT-11:00 | 0.00 | 0.00 | 0.00 | 1698.40 | 31-OCT-11:20 | 0.00 |
November | 13368.95 | 10-NOV-12:00 | 0.00 | 0.00 | 0.00 | 1702.20 | 29-NOV-12:39 | 0.00 |
December | 12825.57 | 12-DEC-12:00 | 0.00 | 0.00 | 0.00 | 1704.42 | 30-DEC-12:30 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 12825.57 | 0.00 | 0.00 | 0.00 | 1687.61 | 0.00 | ||
Maximum of Months | 19529.61 | 0.00 | 0.00 | 0.00 | 1704.69 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 38736.88 | 05-JAN-16:00 | 13166.11 | 10112.62 | 0.00 | 0.00 | 4090.51 | 0.00 | 0.00 | 10884.64 | 0.00 |
February | 39053.76 | 28-FEB-14:50 | 8241.91 | 10112.62 | 0.00 | 0.00 | 4429.39 | 0.00 | 0.00 | 14612.75 | 0.00 |
March | 39855.54 | 27-MAR-13:50 | 8257.07 | 10112.62 | 0.00 | 0.00 | 4563.06 | 0.00 | 0.00 | 15268.26 | 0.00 |
April | 41166.86 | 11-APR-15:00 | 9335.50 | 10112.62 | 0.00 | 0.00 | 4769.29 | 0.00 | 0.00 | 16466.44 | 0.00 |
May | 44160.05 | 06-MAY-15:09 | 7834.87 | 10112.62 | 0.00 | 0.00 | 5268.55 | 0.00 | 0.00 | 19529.61 | 0.00 |
June | 43864.38 | 13-JUN-14:50 | 8741.50 | 10112.62 | 0.00 | 0.00 | 5040.72 | 0.00 | 0.00 | 18302.06 | 0.00 |
July | 37972.88 | 19-JUL-14:00 | 8741.50 | 10112.62 | 0.00 | 0.00 | 4209.15 | 0.00 | 0.00 | 13243.27 | 0.00 |
August | 40463.39 | 11-AUG-14:20 | 8241.91 | 10112.62 | 0.00 | 0.00 | 4636.76 | 0.00 | 0.00 | 15804.55 | 0.00 |
September | 39743.61 | 06-SEP-14:20 | 8241.91 | 10112.62 | 0.00 | 0.00 | 4541.24 | 0.00 | 0.00 | 15178.46 | 0.00 |
October | 39142.26 | 04-OCT-15:39 | 8894.69 | 10112.62 | 0.00 | 0.00 | 4385.55 | 0.00 | 0.00 | 14172.64 | 0.00 |
November | 39368.85 | 10-NOV-16:00 | 13263.53 | 10112.62 | 0.00 | 0.00 | 4087.25 | 0.00 | 0.00 | 10327.10 | 0.00 |
December | 39038.65 | 13-DEC-16:49 | 12548.47 | 10112.62 | 0.00 | 0.00 | 4081.20 | 0.00 | 0.00 | 10717.04 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 37972.88 | 7834.87 | 10112.62 | 0.00 | 0.00 | 4081.20 | 0.00 | 0.00 | 10327.10 | 0.00 | |
Maximum of Months | 44160.05 | 13263.53 | 10112.62 | 0.00 | 0.00 | 5268.55 | 0.00 | 0.00 | 19529.61 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 30.03 | 0.00 | 30.03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 30.02 | 0.00 | 30.02 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 28.17 | 0.50 | 27.72 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 2.83 | 27.25 | 2.33 | 26.99 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 4.83 | 25.90 | 4.33 | 25.68 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 4.67 | 25.88 | 4.17 | 25.64 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 29.47 | 0.33 | 29.21 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.33 | 26.19 | 3.17 | 26.10 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.50 | 27.08 | 1.00 | 26.50 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 28.51 | 0.33 | 27.84 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 28.49 | 0.50 | 27.98 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 30.00 | 0.00 | 30.00 |
Annual Sum or Average | 0.00 | 0.00 | 23.00 | 27.01 | 16.67 | 26.54 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 25.88 | 0.00 | 25.64 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 4.83 | 30.03 | 4.33 | 30.03 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 21.50 | 27.43 | 0.00 | 27.43 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 21.83 | 27.46 | 0.00 | 27.46 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 25.83 | 27.50 | 1.17 | 27.49 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 30.67 | 27.48 | 2.00 | 27.47 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 28.33 | 27.49 | 0.17 | 27.49 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 29.17 | 27.50 | 1.00 | 27.49 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 32.17 | 27.40 | 1.33 | 27.40 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 21.83 | 27.43 | 1.00 | 27.42 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 27.00 | 27.42 | 1.17 | 27.42 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 26.33 | 27.41 | 0.33 | 27.41 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 20.67 | 27.42 | 0.17 | 27.42 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 18.83 | 27.45 | 0.00 | 27.45 |
Annual Sum or Average | 0.00 | 0.00 | 304.17 | 27.45 | 8.33 | 27.45 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 18.83 | 27.40 | 0.00 | 27.40 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 32.17 | 27.50 | 2.00 | 27.49 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 61.17 | 26.07 | 300.00 | 24.65 | 61.17 | 24.86 |
February | 54.33 | 26.24 | 276.00 | 24.69 | 54.33 | 24.91 |
March | 72.17 | 26.08 | 324.00 | 24.70 | 72.17 | 24.91 |
April | 83.67 | 25.66 | 300.00 | 24.67 | 83.67 | 24.85 |
May | 127.33 | 25.12 | 312.00 | 24.60 | 127.33 | 24.72 |
June | 123.83 | 25.16 | 312.00 | 24.62 | 123.83 | 24.74 |
July | 81.83 | 25.71 | 300.00 | 24.68 | 81.83 | 24.86 |
August | 139.00 | 25.05 | 324.00 | 24.59 | 139.00 | 24.70 |
September | 111.33 | 25.23 | 300.00 | 24.62 | 111.33 | 24.75 |
October | 113.50 | 25.20 | 300.00 | 24.61 | 113.50 | 24.74 |
November | 86.33 | 25.51 | 288.00 | 24.65 | 86.33 | 24.81 |
December | 65.83 | 25.88 | 300.00 | 24.62 | 65.83 | 24.81 |
Annual Sum or Average | 1120.33 | 25.46 | 3636.00 | 24.64 | 1120.33 | 24.80 |
Minimum of Months | 54.33 | 25.05 | 276.00 | 24.59 | 54.33 | 24.70 |
Maximum of Months | 139.00 | 26.24 | 324.00 | 24.70 | 139.00 | 24.91 |
Report: ComfortReportSimple55Monthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 295.33 | 26.72 | 300.00 | 26.71 | 295.33 | 26.71 |
February | 272.83 | 26.72 | 276.00 | 26.72 | 272.83 | 26.72 |
March | 324.00 | 26.72 | 324.00 | 26.72 | 324.00 | 26.72 |
April | 300.00 | 26.72 | 300.00 | 26.72 | 300.00 | 26.72 |
May | 312.00 | 26.72 | 312.00 | 26.72 | 312.00 | 26.72 |
June | 312.00 | 26.71 | 312.00 | 26.71 | 312.00 | 26.71 |
July | 298.33 | 26.72 | 300.00 | 26.72 | 298.33 | 26.72 |
August | 324.00 | 26.72 | 324.00 | 26.72 | 324.00 | 26.72 |
September | 300.00 | 26.72 | 300.00 | 26.72 | 300.00 | 26.72 |
October | 300.00 | 26.73 | 300.00 | 26.73 | 300.00 | 26.73 |
November | 288.00 | 26.72 | 288.00 | 26.72 | 288.00 | 26.72 |
December | 299.50 | 26.70 | 300.00 | 26.70 | 299.50 | 26.70 |
Annual Sum or Average | 3626.00 | 26.72 | 3636.00 | 26.72 | 3626.00 | 26.72 |
Minimum of Months | 272.83 | 26.70 | 276.00 | 26.70 | 272.83 | 26.70 |
Maximum of Months | 324.00 | 26.73 | 324.00 | 26.73 | 324.00 | 26.73 |
Report: ComfortReportSimple55Monthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 300.00 | 30.00 | 300.00 | 30.00 | 300.00 | 30.00 |
February | 276.00 | 30.70 | 276.00 | 30.70 | 276.00 | 30.70 |
March | 324.00 | 31.15 | 324.00 | 31.15 | 324.00 | 31.15 |
April | 300.00 | 31.33 | 300.00 | 31.33 | 300.00 | 31.33 |
May | 312.00 | 31.34 | 312.00 | 31.34 | 312.00 | 31.34 |
June | 312.00 | 31.41 | 312.00 | 31.41 | 312.00 | 31.41 |
July | 300.00 | 30.15 | 300.00 | 30.15 | 300.00 | 30.15 |
August | 324.00 | 30.34 | 324.00 | 30.34 | 324.00 | 30.34 |
September | 300.00 | 30.36 | 300.00 | 30.36 | 300.00 | 30.36 |
October | 300.00 | 29.88 | 300.00 | 29.88 | 300.00 | 29.88 |
November | 288.00 | 29.93 | 288.00 | 29.93 | 288.00 | 29.93 |
December | 300.00 | 29.87 | 300.00 | 29.87 | 300.00 | 29.87 |
Annual Sum or Average | 3636.00 | 30.55 | 3636.00 | 30.55 | 3636.00 | 30.55 |
Minimum of Months | 276.00 | 29.87 | 276.00 | 29.87 | 276.00 | 29.87 |
Maximum of Months | 324.00 | 31.41 | 324.00 | 31.41 | 324.00 | 31.41 |
Report: OccupantComfortDataSummaryMonthly
For: OFFICE PEOPLE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: ZONE2 FINE STORAGEPEOPLE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: ZONE3 BULK STORAGEPEOPLE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.128875E+11 | 0.305876E+10 | 277.89 | 0.906282E+10 | 0.382471E+10 | 0.00 | 1.00 | 02-JAN-06:03 | 0.00 | 01-JAN-00:10 | 32127.57 | 02-JAN-07:01 | 20162.38 | 24-JAN-07:03 | 16389.40 | 02-JAN-07:04 | 6504.61 | 02-JAN-07:01 | 0.00 | 01-JAN-00:10 |
February | 0.124936E+11 | 0.300730E+10 | 260.09 | 0.886080E+10 | 0.363276E+10 | 0.00 | 1.00 | 01-FEB-07:02 | 0.00 | 01-FEB-00:10 | 31545.05 | 16-FEB-07:01 | 21741.87 | 23-FEB-07:01 | 15551.48 | 16-FEB-08:62 | 6524.43 | 16-FEB-07:01 | 0.00 | 01-FEB-00:10 |
March | 0.157985E+11 | 0.383729E+10 | 309.31 | 0.109329E+11 | 0.486557E+10 | 0.00 | 1.00 | 01-MAR-07:01 | 0.00 | 01-MAR-00:03 | 31809.41 | 15-MAR-06:02 | 19889.32 | 04-MAR-07:02 | 16252.66 | 25-MAR-06:04 | 6585.22 | 28-MAR-06:01 | 0.00 | 01-MAR-00:03 |
April | 0.161094E+11 | 0.389512E+10 | 291.34 | 0.104418E+11 | 0.566760E+10 | 0.00 | 1.00 | 01-APR-06:01 | 0.00 | 01-APR-00:10 | 31791.16 | 24-APR-06:01 | 17421.81 | 27-APR-06:01 | 16708.42 | 21-APR-06:04 | 6591.10 | 11-APR-06:01 | 0.00 | 01-APR-00:10 |
May | 0.181910E+11 | 0.435993E+10 | 305.14 | 0.109294E+11 | 0.726158E+10 | 0.00 | 1.00 | 01-MAY-05:02 | 0.00 | 01-MAY-00:05 | 32088.05 | 09-MAY-06:01 | 16573.99 | 31-MAY-06:01 | 19842.08 | 22-MAY-05:03 | 6692.63 | 05-MAY-07:03 | 0.00 | 01-MAY-00:05 |
June | 0.185517E+11 | 0.445679E+10 | 305.41 | 0.111738E+11 | 0.737784E+10 | 0.00 | 1.00 | 01-JUN-06:01 | 0.00 | 01-JUN-00:10 | 32127.57 | 21-JUN-06:01 | 16514.58 | 03-JUN-06:02 | 18750.33 | 10-JUN-06:06 | 6647.94 | 14-JUN-07:03 | 0.00 | 01-JUN-00:10 |
July | 0.146426E+11 | 0.341820E+10 | 284.16 | 0.947349E+10 | 0.516910E+10 | 0.00 | 1.00 | 01-JUL-06:01 | 0.00 | 01-JUL-00:10 | 31871.76 | 24-JUL-06:01 | 18456.72 | 17-JUL-06:01 | 15789.45 | 01-JUL-06:04 | 6533.55 | 01-JUL-06:01 | 0.00 | 01-JUL-00:10 |
August | 0.176936E+11 | 0.412000E+10 | 305.42 | 0.103517E+11 | 0.734193E+10 | 0.00 | 1.00 | 01-AUG-06:01 | 0.00 | 01-AUG-00:10 | 32042.46 | 04-AUG-06:03 | 16685.38 | 24-AUG-06:01 | 18924.27 | 25-AUG-06:06 | 6601.71 | 09-AUG-07:03 | 0.00 | 01-AUG-00:10 |
September | 0.157241E+11 | 0.367258E+10 | 285.89 | 0.953578E+10 | 0.618829E+10 | 0.00 | 1.00 | 01-SEP-06:01 | 0.00 | 01-SEP-00:03 | 32060.69 | 19-SEP-06:01 | 17454.26 | 12-SEP-06:01 | 17960.51 | 25-SEP-06:13 | 6582.34 | 08-SEP-06:01 | 0.00 | 01-SEP-00:03 |
October | 0.148306E+11 | 0.342045E+10 | 281.08 | 0.895679E+10 | 0.587376E+10 | 0.00 | 1.00 | 02-OCT-05:03 | 0.00 | 01-OCT-00:10 | 32127.57 | 23-OCT-06:01 | 17049.37 | 07-OCT-06:01 | 17754.34 | 23-OCT-06:04 | 6572.85 | 05-OCT-06:01 | 0.00 | 01-OCT-00:10 |
November | 0.135604E+11 | 0.315349E+10 | 267.18 | 0.866915E+10 | 0.489120E+10 | 0.00 | 1.00 | 01-NOV-06:01 | 0.00 | 01-NOV-00:10 | 31800.94 | 03-NOV-06:01 | 19322.21 | 25-NOV-07:02 | 16984.40 | 13-NOV-07:05 | 6570.15 | 15-NOV-07:01 | 0.00 | 01-NOV-00:10 |
December | 0.126549E+11 | 0.297397E+10 | 277.38 | 0.869977E+10 | 0.395517E+10 | 0.00 | 1.00 | 01-DEC-07:02 | 0.00 | 01-DEC-00:10 | 31839.23 | 11-DEC-07:01 | 19647.05 | 16-DEC-07:02 | 15694.17 | 11-DEC-07:04 | 6509.77 | 30-DEC-07:01 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.183138E+12 | 0.433739E+11 | 3450.29 | 0.117088E+12 | 0.660495E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.124936E+11 | 0.297397E+10 | 260.09 | 0.866915E+10 | 0.363276E+10 | 0.00 | 1.00 | 0.00 | 31545.05 | 16514.58 | 15551.48 | 6504.61 | 0.00 | |||||||
Maximum of Months | 0.185517E+11 | 0.445679E+10 | 309.31 | 0.111738E+11 | 0.737784E+10 | 0.00 | 1.00 | 0.00 | 32127.57 | 21741.87 | 19842.08 | 6692.63 | 0.00 |
Report: DXReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.302150E+11 | 0.746172E+10 | 390.72 | 0.200103E+11 | 0.102046E+11 | 0.00 | 1.00 | 01-JAN-11:55 | 0.00 | 01-JAN-00:10 | 84281.07 | 11-JAN-07:01 | 59317.34 | 16-JAN-16:53 | 41804.61 | 10-JAN-07:01 | 18191.80 | 08-JAN-12:13 | 0.00 | 01-JAN-00:10 |
February | 0.325616E+11 | 0.806818E+10 | 397.01 | 0.218389E+11 | 0.107227E+11 | 0.00 | 1.00 | 01-FEB-18:10 | 0.00 | 01-FEB-00:13 | 78154.62 | 17-FEB-18:10 | 58092.88 | 26-FEB-14:23 | 32451.94 | 12-FEB-07:29 | 18640.54 | 26-FEB-13:43 | 0.00 | 01-FEB-00:10 |
March | 0.433536E+11 | 0.107256E+11 | 487.28 | 0.281921E+11 | 0.151615E+11 | 0.00 | 1.00 | 01-MAR-18:10 | 0.00 | 01-MAR-00:03 | 81935.62 | 23-MAR-06:01 | 58250.69 | 19-MAR-13:53 | 36265.76 | 24-MAR-06:01 | 18920.02 | 26-MAR-13:43 | 0.00 | 01-MAR-00:03 |
April | 0.481061E+11 | 0.117524E+11 | 514.08 | 0.290578E+11 | 0.190483E+11 | 0.00 | 1.00 | 01-APR-06:01 | 0.00 | 01-APR-00:15 | 83345.33 | 13-APR-06:01 | 55480.81 | 23-APR-14:32 | 36751.95 | 13-APR-06:01 | 18991.30 | 02-APR-14:32 | 0.00 | 01-APR-00:10 |
May | 0.520798E+11 | 0.125781E+11 | 521.13 | 0.288599E+11 | 0.232198E+11 | 0.00 | 1.00 | 01-MAY-00:15 | 0.00 | 01-MAY-00:05 | 85879.89 | 25-MAY-06:01 | 54976.64 | 07-MAY-13:02 | 48155.23 | 22-MAY-06:02 | 19158.43 | 21-MAY-09:33 | 0.00 | 01-MAY-00:05 |
June | 0.542656E+11 | 0.130516E+11 | 521.58 | 0.301000E+11 | 0.241656E+11 | 0.00 | 1.00 | 01-JUN-05:48 | 0.00 | 01-JUN-00:10 | 85927.41 | 02-JUN-06:01 | 51535.71 | 18-JUN-14:23 | 44264.72 | 10-JUN-06:01 | 19502.94 | 18-JUN-13:43 | 0.00 | 01-JUN-00:10 |
July | 0.383168E+11 | 0.925173E+10 | 478.72 | 0.231282E+11 | 0.151886E+11 | 0.00 | 1.00 | 01-JUL-17:08 | 0.00 | 01-JUL-00:10 | 81880.32 | 31-JUL-17:10 | 55070.30 | 16-JUL-14:13 | 35412.69 | 14-JUL-06:01 | 18759.66 | 26-JUL-17:06 | 0.00 | 01-JUL-00:10 |
August | 0.442188E+11 | 0.104473E+11 | 468.30 | 0.232921E+11 | 0.209267E+11 | 0.00 | 1.00 | 01-AUG-06:01 | 0.00 | 01-AUG-00:10 | 89117.35 | 04-AUG-06:01 | 51532.33 | 27-AUG-15:32 | 52772.92 | 04-AUG-06:01 | 19301.98 | 13-AUG-13:13 | 0.00 | 01-AUG-00:10 |
September | 0.409920E+11 | 0.977727E+10 | 467.16 | 0.228564E+11 | 0.181356E+11 | 0.00 | 1.00 | 01-SEP-06:01 | 0.00 | 01-SEP-00:03 | 88131.33 | 21-SEP-06:01 | 54413.47 | 10-SEP-13:43 | 48151.60 | 21-SEP-06:01 | 18854.15 | 04-SEP-14:03 | 0.00 | 01-SEP-00:03 |
October | 0.354588E+11 | 0.843600E+10 | 434.39 | 0.195606E+11 | 0.158982E+11 | 0.00 | 1.00 | 01-OCT-08:45 | 0.00 | 01-OCT-00:30 | 89193.43 | 14-OCT-06:01 | 52184.42 | 08-OCT-16:23 | 51293.90 | 14-OCT-06:01 | 18783.37 | 29-OCT-12:43 | 0.00 | 01-OCT-00:10 |
November | 0.318850E+11 | 0.768278E+10 | 401.04 | 0.188570E+11 | 0.130280E+11 | 0.00 | 1.00 | 01-NOV-06:01 | 0.00 | 01-NOV-00:20 | 84342.56 | 22-NOV-07:01 | 55981.36 | 05-NOV-15:13 | 44324.48 | 09-NOV-07:02 | 18363.34 | 12-NOV-14:13 | 0.00 | 01-NOV-00:10 |
December | 0.288893E+11 | 0.708317E+10 | 379.87 | 0.184099E+11 | 0.104794E+11 | 0.00 | 1.00 | 03-DEC-08:30 | 0.00 | 01-DEC-00:10 | 86858.88 | 12-DEC-07:01 | 58383.12 | 03-DEC-15:43 | 44276.20 | 12-DEC-07:01 | 18408.48 | 24-DEC-12:03 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.480342E+12 | 0.116316E+12 | 5461.28 | 0.284163E+12 | 0.196179E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.288893E+11 | 0.708317E+10 | 379.87 | 0.184099E+11 | 0.102046E+11 | 0.00 | 1.00 | 0.00 | 78154.62 | 51532.33 | 32451.94 | 18191.80 | 0.00 | |||||||
Maximum of Months | 0.542656E+11 | 0.130516E+11 | 521.58 | 0.301000E+11 | 0.241656E+11 | 0.00 | 1.00 | 0.00 | 89193.43 | 59317.34 | 52772.92 | 19502.94 | 0.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 82.77 | 29.23 | 53.54 | 152.32 | 30.29 | 0.00 | 0.00 | 0.00 |
February | 90.67 | 32.09 | 58.58 | 171.10 | 25.91 | 0.00 | 0.00 | 0.00 |
March | 101.69 | 40.20 | 61.49 | 195.99 | 21.37 | 0.00 | 0.00 | 0.00 |
April | 102.00 | 38.99 | 63.01 | 196.79 | 13.70 | 0.00 | 0.00 | 0.00 |
May | 86.89 | 25.74 | 61.16 | 171.90 | 14.04 | 0.00 | 0.00 | 0.00 |
June | 94.11 | 32.41 | 61.71 | 184.37 | 14.86 | 0.00 | 0.00 | 0.00 |
July | 80.32 | 18.96 | 61.36 | 149.43 | 20.81 | 0.00 | 0.00 | 0.00 |
August | 87.37 | 25.91 | 61.47 | 160.87 | 18.88 | 0.00 | 0.00 | 0.00 |
September | 81.68 | 22.60 | 59.08 | 153.67 | 18.62 | 0.00 | 0.00 | 0.00 |
October | 76.79 | 19.78 | 57.00 | 138.83 | 21.85 | 0.00 | 0.00 | 0.00 |
November | 74.77 | 20.32 | 54.46 | 136.16 | 23.92 | 0.00 | 0.00 | 0.00 |
December | 76.67 | 25.11 | 51.56 | 140.54 | 32.30 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 86.26 | 27.56 | 58.69 | 162.54 | 21.38 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 74.77 | 18.96 | 51.56 | 136.16 | 13.70 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 102.00 | 40.20 | 63.01 | 196.79 | 32.30 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 82.77 | 29.23 | 53.54 | 152.32 | 30.29 | 0.00 | 0.00 | 0.00 |
February | 90.67 | 32.09 | 58.58 | 171.10 | 25.91 | 0.00 | 0.00 | 0.00 |
March | 101.69 | 40.20 | 61.49 | 195.99 | 21.37 | 0.00 | 0.00 | 0.00 |
April | 102.00 | 38.99 | 63.01 | 196.79 | 13.70 | 0.00 | 0.00 | 0.00 |
May | 86.89 | 25.74 | 61.16 | 171.90 | 14.04 | 0.00 | 0.00 | 0.00 |
June | 94.11 | 32.41 | 61.71 | 184.37 | 14.86 | 0.00 | 0.00 | 0.00 |
July | 80.32 | 18.96 | 61.36 | 149.43 | 20.81 | 0.00 | 0.00 | 0.00 |
August | 87.37 | 25.91 | 61.47 | 160.87 | 18.88 | 0.00 | 0.00 | 0.00 |
September | 81.68 | 22.60 | 59.08 | 153.67 | 18.62 | 0.00 | 0.00 | 0.00 |
October | 76.79 | 19.78 | 57.00 | 138.83 | 21.85 | 0.00 | 0.00 | 0.00 |
November | 74.77 | 20.32 | 54.46 | 136.16 | 23.92 | 0.00 | 0.00 | 0.00 |
December | 76.67 | 25.11 | 51.56 | 140.54 | 32.30 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 86.26 | 27.56 | 58.69 | 162.54 | 21.38 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 74.77 | 18.96 | 51.56 | 136.16 | 13.70 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 102.00 | 40.20 | 63.01 | 196.79 | 32.30 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 24.65 | 0.00 | 24.65 | 45.56 | 17.63 | 0.00 | 0.00 | 0.00 |
February | 26.29 | 0.00 | 26.29 | 51.24 | 15.10 | 0.00 | 0.00 | 0.00 |
March | 27.01 | 0.00 | 27.00 | 55.73 | 12.38 | 0.00 | 0.00 | 0.00 |
April | 29.74 | 0.56 | 29.18 | 62.32 | 7.88 | 0.00 | 0.00 | 0.00 |
May | 37.75 | 4.12 | 33.63 | 80.92 | 8.14 | 0.00 | 0.00 | 0.00 |
June | 45.84 | 9.16 | 36.69 | 97.69 | 8.63 | 0.00 | 0.00 | 0.00 |
July | 39.41 | 4.01 | 35.40 | 76.65 | 11.90 | 0.00 | 0.00 | 0.00 |
August | 32.80 | 1.61 | 31.19 | 63.75 | 10.92 | 0.00 | 0.00 | 0.00 |
September | 27.76 | 0.04 | 27.73 | 54.46 | 10.89 | 0.00 | 0.00 | 0.00 |
October | 26.71 | 0.00 | 26.71 | 48.90 | 12.79 | 0.00 | 0.00 | 0.00 |
November | 25.27 | 0.00 | 25.27 | 46.30 | 13.95 | 0.00 | 0.00 | 0.00 |
December | 23.94 | 0.00 | 23.94 | 43.85 | 18.80 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 30.62 | 1.63 | 28.99 | 60.64 | 12.42 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 23.94 | 0.00 | 23.94 | 43.85 | 7.88 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 45.84 | 9.16 | 36.69 | 97.69 | 18.80 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 24.65 | 0.00 | 24.65 | 45.56 | 17.63 | 0.00 | 0.00 | 0.00 |
February | 26.29 | 0.00 | 26.29 | 51.23 | 15.10 | 0.00 | 0.00 | 0.00 |
March | 27.00 | 0.00 | 27.00 | 55.72 | 12.38 | 0.00 | 0.00 | 0.00 |
April | 29.74 | 0.56 | 29.18 | 62.32 | 7.88 | 0.00 | 0.00 | 0.00 |
May | 37.75 | 4.12 | 33.63 | 80.92 | 8.14 | 0.00 | 0.00 | 0.00 |
June | 45.84 | 9.15 | 36.69 | 97.69 | 8.63 | 0.00 | 0.00 | 0.00 |
July | 39.41 | 4.01 | 35.40 | 76.64 | 11.90 | 0.00 | 0.00 | 0.00 |
August | 32.80 | 1.61 | 31.19 | 63.75 | 10.92 | 0.00 | 0.00 | 0.00 |
September | 27.76 | 0.04 | 27.72 | 54.46 | 10.89 | 0.00 | 0.00 | 0.00 |
October | 26.70 | 0.00 | 26.70 | 48.90 | 12.79 | 0.00 | 0.00 | 0.00 |
November | 25.27 | 0.00 | 25.27 | 46.30 | 13.95 | 0.00 | 0.00 | 0.00 |
December | 23.94 | 0.00 | 23.94 | 43.85 | 18.80 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 30.62 | 1.63 | 28.99 | 60.64 | 12.42 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 23.94 | 0.00 | 23.94 | 43.85 | 7.88 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 45.84 | 9.15 | 36.69 | 97.69 | 18.80 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 161.13 | 20.25 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 186.96 | 20.54 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 217.07 | 17.04 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 220.18 | 12.41 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 185.94 | 10.92 | 0.00 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 200.83 | 10.60 | 0.00 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 167.91 | 13.49 | 0.00 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 179.81 | 13.07 | 0.00 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 171.20 | 12.63 | 0.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 152.22 | 13.93 | 0.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 147.26 | 16.37 | 0.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 149.26 | 21.02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 178.17 | 15.17 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 147.26 | 10.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 220.18 | 21.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_6
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 161.13 | 20.25 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 186.96 | 20.54 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 217.07 | 17.04 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 220.18 | 12.41 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 185.94 | 10.92 | 0.00 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 200.83 | 10.60 | 0.00 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 167.91 | 13.49 | 0.00 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 179.81 | 13.07 | 0.00 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 171.20 | 12.63 | 0.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 152.22 | 13.93 | 0.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 147.26 | 16.37 | 0.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 149.26 | 21.02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 178.17 | 15.17 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 147.26 | 10.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 220.18 | 21.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_7
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 161.13 | 20.25 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 186.96 | 20.54 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 217.07 | 17.04 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 220.18 | 12.41 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 185.94 | 10.92 | 0.00 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 200.83 | 10.60 | 0.00 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 167.91 | 13.49 | 0.00 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 179.81 | 13.07 | 0.00 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 171.20 | 12.63 | 0.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 152.22 | 13.93 | 0.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 147.26 | 16.37 | 0.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 149.26 | 21.02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 178.17 | 15.17 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 147.26 | 10.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 220.18 | 21.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_8
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 161.13 | 20.25 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 186.96 | 20.54 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 217.07 | 17.04 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 220.18 | 12.41 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 185.94 | 10.92 | 0.00 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 200.83 | 10.60 | 0.00 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 167.91 | 13.49 | 0.00 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 179.81 | 13.07 | 0.00 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 171.20 | 12.63 | 0.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 152.22 | 13.93 | 0.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 147.26 | 16.37 | 0.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 149.26 | 21.02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 178.17 | 15.17 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 147.26 | 10.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 220.18 | 21.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_9
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 161.13 | 20.25 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 186.96 | 20.54 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 217.07 | 17.04 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 220.18 | 12.41 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 185.94 | 10.92 | 0.00 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 200.83 | 10.60 | 0.00 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 167.91 | 13.49 | 0.00 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 179.81 | 13.07 | 0.00 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 171.20 | 12.63 | 0.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 152.22 | 13.93 | 0.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 147.26 | 16.37 | 0.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 149.26 | 21.02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 178.17 | 15.17 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 147.26 | 10.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 220.18 | 21.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_10
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 161.13 | 20.25 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 186.96 | 20.54 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 217.07 | 17.04 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 220.18 | 12.41 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 185.94 | 10.92 | 0.00 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 200.83 | 10.60 | 0.00 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 167.91 | 13.49 | 0.00 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 179.81 | 13.07 | 0.00 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 171.20 | 12.63 | 0.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 152.22 | 13.93 | 0.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 147.26 | 16.37 | 0.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 149.26 | 21.02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 178.17 | 15.17 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 147.26 | 10.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 220.18 | 21.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_5
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 161.13 | 20.25 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 186.96 | 20.54 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 217.07 | 17.04 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 220.18 | 12.41 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 185.94 | 10.92 | 0.00 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 200.83 | 10.60 | 0.00 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 167.91 | 13.49 | 0.00 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 179.81 | 13.07 | 0.00 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 171.20 | 12.63 | 0.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 152.22 | 13.93 | 0.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 147.26 | 16.37 | 0.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 149.26 | 21.02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 178.17 | 15.17 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 147.26 | 10.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 220.18 | 21.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 161.13 | 20.25 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 186.96 | 20.54 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 217.07 | 17.04 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 220.18 | 12.41 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 185.94 | 10.92 | 0.00 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 200.83 | 10.60 | 0.00 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 167.91 | 13.49 | 0.00 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 179.81 | 13.07 | 0.00 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 171.20 | 12.63 | 0.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 152.22 | 13.93 | 0.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 147.26 | 16.37 | 0.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 149.26 | 21.02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 178.17 | 15.17 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 147.26 | 10.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 220.18 | 21.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 161.13 | 20.25 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 186.96 | 20.54 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 217.07 | 17.04 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 220.18 | 12.41 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 185.94 | 10.92 | 0.00 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 200.83 | 10.60 | 0.00 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 167.91 | 13.49 | 0.00 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 179.81 | 13.07 | 0.00 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 171.20 | 12.63 | 0.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 152.22 | 13.93 | 0.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 147.26 | 16.37 | 0.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 149.26 | 21.02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 178.17 | 15.17 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 147.26 | 10.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 220.18 | 21.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 161.13 | 20.25 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 186.96 | 20.54 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 217.07 | 17.04 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 220.18 | 12.41 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 185.94 | 10.92 | 0.00 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 200.83 | 10.60 | 0.00 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 167.91 | 13.49 | 0.00 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 179.81 | 13.07 | 0.00 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 171.20 | 12.63 | 0.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 152.22 | 13.93 | 0.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 147.26 | 16.37 | 0.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 149.26 | 21.02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 178.17 | 15.17 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 147.26 | 10.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 220.18 | 21.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_14
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 161.13 | 20.25 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 186.96 | 20.54 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 217.07 | 17.04 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 220.18 | 12.41 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 185.94 | 10.92 | 0.00 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 200.83 | 10.60 | 0.00 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 167.91 | 13.49 | 0.00 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 179.81 | 13.07 | 0.00 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 171.20 | 12.63 | 0.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 152.22 | 13.93 | 0.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 147.26 | 16.37 | 0.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 149.26 | 21.02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 178.17 | 15.17 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 147.26 | 10.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 220.18 | 21.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_13
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 161.13 | 20.25 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 186.96 | 20.54 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 217.07 | 17.04 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 220.18 | 12.41 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 185.94 | 10.92 | 0.00 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 200.83 | 10.60 | 0.00 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 167.91 | 13.49 | 0.00 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 179.81 | 13.07 | 0.00 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 171.20 | 12.63 | 0.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 152.22 | 13.93 | 0.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 147.26 | 16.37 | 0.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 149.26 | 21.02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 178.17 | 15.17 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 147.26 | 10.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 220.18 | 21.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_12
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 161.13 | 20.25 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 186.96 | 20.54 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 217.07 | 17.04 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 220.18 | 12.41 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 185.94 | 10.92 | 0.00 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 200.83 | 10.60 | 0.00 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 167.91 | 13.49 | 0.00 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 179.81 | 13.07 | 0.00 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 171.20 | 12.63 | 0.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 152.22 | 13.93 | 0.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 147.26 | 16.37 | 0.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 149.26 | 21.02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 178.17 | 15.17 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 147.26 | 10.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 220.18 | 21.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_11
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 161.13 | 20.25 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 186.96 | 20.54 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 217.07 | 17.04 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 220.18 | 12.41 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 185.94 | 10.92 | 0.00 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 200.83 | 10.60 | 0.00 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 167.91 | 13.49 | 0.00 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 179.81 | 13.07 | 0.00 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 171.20 | 12.63 | 0.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 152.22 | 13.93 | 0.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 147.26 | 16.37 | 0.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 149.26 | 21.02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 178.17 | 15.17 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 147.26 | 10.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 220.18 | 21.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R8C1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R8C2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R8C4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R3C4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R3C2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R3C3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R3C1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R4C4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R4C3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R4C2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R4C1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R5C4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R5C1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R5C3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R5C2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R6C1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R6C2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R8C3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R6C4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R7C1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R7C2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R7C4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R6C3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R7C3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 118.27 | 56.57 | 61.70 | 157.18 | 26.09 | 0.00 | 0.00 | 0.00 |
February | 136.10 | 70.40 | 65.70 | 181.37 | 27.57 | 0.00 | 0.00 | 0.00 |
March | 157.96 | 92.41 | 65.55 | 210.45 | 24.29 | 0.00 | 0.00 | 0.00 |
April | 159.65 | 89.13 | 70.52 | 212.80 | 19.63 | 0.00 | 0.00 | 0.00 |
May | 133.85 | 57.97 | 75.87 | 178.00 | 18.42 | 110.33 | 0.00 | 0.00 |
June | 144.67 | 71.36 | 73.30 | 193.04 | 17.78 | 38.83 | 0.00 | 0.00 |
July | 121.87 | 40.24 | 81.62 | 162.53 | 19.58 | 0.67 | 0.00 | 0.00 |
August | 134.47 | 57.51 | 76.97 | 173.65 | 19.34 | 33.83 | 0.00 | 0.00 |
September | 124.38 | 48.15 | 76.23 | 165.55 | 19.16 | 2.00 | 0.00 | 0.00 |
October | 113.78 | 40.23 | 73.54 | 147.02 | 20.62 | 11.00 | 0.00 | 0.00 |
November | 108.37 | 40.82 | 67.55 | 142.54 | 22.73 | 2.00 | 0.00 | 0.00 |
December | 109.66 | 49.16 | 60.49 | 144.84 | 27.40 | 13.33 | 0.00 | 0.00 |
Annual Sum or Average | 130.16 | 59.38 | 70.78 | 172.27 | 21.86 | 212.00 | 0.00 | 0.00 |
Minimum of Months | 108.37 | 40.23 | 60.49 | 142.54 | 17.78 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 159.65 | 92.41 | 81.62 | 212.80 | 27.57 | 110.33 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.221681E+09 | 78284555.57 | 0.143396E+09 | 0.407967E+09 | 81123159.86 |
February | 0.219348E+09 | 77633443.43 | 0.141714E+09 | 0.413922E+09 | 62673889.85 |
March | 0.272367E+09 | 0.107680E+09 | 0.164687E+09 | 0.524930E+09 | 57238558.96 |
April | 0.264381E+09 | 0.101056E+09 | 0.163326E+09 | 0.510077E+09 | 35521168.51 |
May | 0.232730E+09 | 68932137.35 | 0.163798E+09 | 0.460430E+09 | 37614872.55 |
June | 0.243945E+09 | 84003696.89 | 0.159941E+09 | 0.477881E+09 | 38507153.23 |
July | 0.215136E+09 | 50784937.62 | 0.164351E+09 | 0.400241E+09 | 55741960.61 |
August | 0.234022E+09 | 69388628.09 | 0.164634E+09 | 0.430863E+09 | 50564282.18 |
September | 0.211721E+09 | 58582592.98 | 0.153138E+09 | 0.398316E+09 | 48273652.58 |
October | 0.205662E+09 | 52990425.58 | 0.152671E+09 | 0.371835E+09 | 58518434.79 |
November | 0.193813E+09 | 52665452.63 | 0.141148E+09 | 0.352919E+09 | 61992478.49 |
December | 0.205363E+09 | 67253785.62 | 0.138109E+09 | 0.376425E+09 | 86505477.82 |
Annual Sum or Average | 0.272017E+10 | 0.869256E+09 | 0.185091E+10 | 0.512581E+10 | 0.674275E+09 |
Minimum of Months | 0.193813E+09 | 50784937.62 | 0.138109E+09 | 0.352919E+09 | 35521168.51 |
Maximum of Months | 0.272367E+09 | 0.107680E+09 | 0.164687E+09 | 0.524930E+09 | 86505477.82 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.221681E+09 | 78284555.57 | 0.143396E+09 | 0.407967E+09 | 81123159.86 |
February | 0.219348E+09 | 77633443.43 | 0.141714E+09 | 0.413922E+09 | 62673889.85 |
March | 0.272367E+09 | 0.107680E+09 | 0.164687E+09 | 0.524930E+09 | 57238558.96 |
April | 0.264381E+09 | 0.101056E+09 | 0.163326E+09 | 0.510077E+09 | 35521168.51 |
May | 0.232730E+09 | 68932137.35 | 0.163798E+09 | 0.460430E+09 | 37614872.55 |
June | 0.243945E+09 | 84003696.89 | 0.159941E+09 | 0.477881E+09 | 38507153.23 |
July | 0.215136E+09 | 50784937.62 | 0.164351E+09 | 0.400241E+09 | 55741960.61 |
August | 0.234022E+09 | 69388628.09 | 0.164634E+09 | 0.430863E+09 | 50564282.18 |
September | 0.211721E+09 | 58582592.98 | 0.153138E+09 | 0.398316E+09 | 48273652.58 |
October | 0.205662E+09 | 52990425.58 | 0.152671E+09 | 0.371835E+09 | 58518434.79 |
November | 0.193813E+09 | 52665452.63 | 0.141148E+09 | 0.352919E+09 | 61992478.49 |
December | 0.205363E+09 | 67253785.62 | 0.138109E+09 | 0.376425E+09 | 86505477.82 |
Annual Sum or Average | 0.272017E+10 | 0.869256E+09 | 0.185091E+10 | 0.512581E+10 | 0.674275E+09 |
Minimum of Months | 0.193813E+09 | 50784937.62 | 0.138109E+09 | 0.352919E+09 | 35521168.51 |
Maximum of Months | 0.272367E+09 | 0.107680E+09 | 0.164687E+09 | 0.524930E+09 | 86505477.82 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 66014107.71 | 0.00 | 66014107.71 | 0.122027E+09 | 47218899.72 |
February | 63604241.65 | 0.00 | 63604241.65 | 0.123948E+09 | 36527131.05 |
March | 72330530.75 | 12772.18 | 72317758.57 | 0.149256E+09 | 33149176.67 |
April | 77095458.20 | 1452960.40 | 75642497.80 | 0.161526E+09 | 20433848.14 |
May | 0.101115E+09 | 11035434.82 | 90079927.44 | 0.216748E+09 | 21807043.24 |
June | 0.118824E+09 | 23729916.09 | 95094421.52 | 0.253221E+09 | 22378966.59 |
July | 0.105552E+09 | 10743834.65 | 94808014.59 | 0.205288E+09 | 31882003.05 |
August | 87854349.87 | 4315389.29 | 83538960.58 | 0.170749E+09 | 29253345.19 |
September | 71964609.48 | 99284.84 | 71865324.64 | 0.141160E+09 | 28226513.35 |
October | 71527824.82 | 0.00 | 71527824.82 | 0.130968E+09 | 34246960.63 |
November | 65497815.40 | 0.00 | 65497815.40 | 0.120015E+09 | 36156957.69 |
December | 64131789.98 | 0.00 | 64131789.98 | 0.117458E+09 | 50352022.30 |
Annual Sum or Average | 0.965512E+09 | 51389592.26 | 0.914123E+09 | 0.191237E+10 | 0.391633E+09 |
Minimum of Months | 63604241.65 | 0.00 | 63604241.65 | 0.117458E+09 | 20433848.14 |
Maximum of Months | 0.118824E+09 | 23729916.09 | 95094421.52 | 0.253221E+09 | 50352022.30 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 66012072.14 | 0.00 | 66012072.14 | 0.122024E+09 | 47218148.87 |
February | 63602352.55 | 0.00 | 63602352.55 | 0.123946E+09 | 36526280.94 |
March | 72328517.32 | 12771.58 | 72315745.74 | 0.149253E+09 | 33148344.91 |
April | 77093195.21 | 1452892.29 | 75640302.92 | 0.161523E+09 | 20433182.52 |
May | 0.101112E+09 | 11034917.57 | 90076890.72 | 0.216742E+09 | 21806515.69 |
June | 0.118820E+09 | 23728803.84 | 95091198.75 | 0.253213E+09 | 22378505.44 |
July | 0.105548E+09 | 10743331.07 | 94804660.23 | 0.205281E+09 | 31881445.84 |
August | 87851422.41 | 4315187.02 | 83536235.39 | 0.170744E+09 | 29252783.28 |
September | 71962306.01 | 99280.19 | 71863025.82 | 0.141157E+09 | 28226015.74 |
October | 71525490.68 | 0.00 | 71525490.68 | 0.130965E+09 | 34246472.55 |
November | 65495689.49 | 0.00 | 65495689.49 | 0.120012E+09 | 36156362.31 |
December | 64129771.06 | 0.00 | 64129771.06 | 0.117455E+09 | 50351302.51 |
Annual Sum or Average | 0.965481E+09 | 51387183.56 | 0.914093E+09 | 0.191231E+10 | 0.391625E+09 |
Minimum of Months | 63602352.55 | 0.00 | 63602352.55 | 0.117455E+09 | 20433182.52 |
Maximum of Months | 0.118820E+09 | 23728803.84 | 95091198.75 | 0.253213E+09 | 50351302.51 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.431574E+09 | 54249153.31 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.452284E+09 | 49687376.44 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.581400E+09 | 45631156.68 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.570702E+09 | 32174948.17 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.498020E+09 | 29251788.97 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.520543E+09 | 27484511.57 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.449726E+09 | 36140562.69 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.481608E+09 | 35008705.58 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.443758E+09 | 32724891.26 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.407696E+09 | 37320104.40 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.381697E+09 | 42423059.01 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.399768E+09 | 56292873.46 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.561878E+10 | 0.478389E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.381697E+09 | 27484511.57 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.581400E+09 | 56292873.46 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_6
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.431574E+09 | 54249153.31 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.452284E+09 | 49687376.44 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.581400E+09 | 45631156.68 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.570702E+09 | 32174948.17 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.498020E+09 | 29251788.97 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.520543E+09 | 27484511.57 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.449726E+09 | 36140562.69 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.481608E+09 | 35008705.58 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.443758E+09 | 32724891.26 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.407696E+09 | 37320104.40 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.381697E+09 | 42423059.01 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.399768E+09 | 56292873.46 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.561878E+10 | 0.478389E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.381697E+09 | 27484511.57 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.581400E+09 | 56292873.46 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_7
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.431574E+09 | 54249153.31 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.452284E+09 | 49687376.44 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.581400E+09 | 45631156.68 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.570702E+09 | 32174948.17 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.498020E+09 | 29251788.97 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.520543E+09 | 27484511.57 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.449726E+09 | 36140562.69 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.481608E+09 | 35008705.58 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.443758E+09 | 32724891.26 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.407696E+09 | 37320104.40 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.381697E+09 | 42423059.01 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.399768E+09 | 56292873.46 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.561878E+10 | 0.478389E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.381697E+09 | 27484511.57 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.581400E+09 | 56292873.46 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_8
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.431574E+09 | 54249153.31 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.452284E+09 | 49687376.44 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.581400E+09 | 45631156.68 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.570702E+09 | 32174948.17 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.498020E+09 | 29251788.97 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.520543E+09 | 27484511.57 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.449726E+09 | 36140562.69 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.481608E+09 | 35008705.58 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.443758E+09 | 32724891.26 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.407696E+09 | 37320104.40 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.381697E+09 | 42423059.01 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.399768E+09 | 56292873.46 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.561878E+10 | 0.478389E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.381697E+09 | 27484511.57 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.581400E+09 | 56292873.46 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_9
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.431574E+09 | 54249153.31 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.452284E+09 | 49687376.44 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.581400E+09 | 45631156.68 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.570702E+09 | 32174948.17 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.498020E+09 | 29251788.97 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.520543E+09 | 27484511.57 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.449726E+09 | 36140562.69 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.481608E+09 | 35008705.58 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.443758E+09 | 32724891.26 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.407696E+09 | 37320104.40 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.381697E+09 | 42423059.01 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.399768E+09 | 56292873.46 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.561878E+10 | 0.478389E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.381697E+09 | 27484511.57 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.581400E+09 | 56292873.46 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_10
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.431574E+09 | 54249153.31 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.452284E+09 | 49687376.44 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.581400E+09 | 45631156.68 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.570702E+09 | 32174948.17 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.498020E+09 | 29251788.97 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.520543E+09 | 27484511.57 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.449726E+09 | 36140562.69 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.481608E+09 | 35008705.58 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.443758E+09 | 32724891.26 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.407696E+09 | 37320104.40 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.381697E+09 | 42423059.01 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.399768E+09 | 56292873.46 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.561878E+10 | 0.478389E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.381697E+09 | 27484511.57 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.581400E+09 | 56292873.46 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_5
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.431574E+09 | 54249153.31 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.452284E+09 | 49687376.44 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.581400E+09 | 45631156.68 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.570702E+09 | 32174948.17 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.498020E+09 | 29251788.97 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.520543E+09 | 27484511.57 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.449726E+09 | 36140562.69 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.481608E+09 | 35008705.58 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.443758E+09 | 32724891.26 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.407696E+09 | 37320104.40 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.381697E+09 | 42423059.01 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.399768E+09 | 56292873.46 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.561878E+10 | 0.478389E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.381697E+09 | 27484511.57 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.581400E+09 | 56292873.46 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.431574E+09 | 54249153.31 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.452284E+09 | 49687376.44 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.581400E+09 | 45631156.68 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.570702E+09 | 32174948.17 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.498020E+09 | 29251788.97 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.520543E+09 | 27484511.57 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.449726E+09 | 36140562.69 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.481608E+09 | 35008705.58 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.443758E+09 | 32724891.26 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.407696E+09 | 37320104.40 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.381697E+09 | 42423059.01 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.399768E+09 | 56292873.46 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.561878E+10 | 0.478389E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.381697E+09 | 27484511.57 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.581400E+09 | 56292873.46 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.431574E+09 | 54249153.31 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.452284E+09 | 49687376.44 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.581400E+09 | 45631156.68 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.570702E+09 | 32174948.17 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.498020E+09 | 29251788.97 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.520543E+09 | 27484511.57 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.449726E+09 | 36140562.69 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.481608E+09 | 35008705.58 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.443758E+09 | 32724891.26 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.407696E+09 | 37320104.40 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.381697E+09 | 42423059.01 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.399768E+09 | 56292873.46 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.561878E+10 | 0.478389E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.381697E+09 | 27484511.57 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.581400E+09 | 56292873.46 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.431574E+09 | 54249153.31 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.452284E+09 | 49687376.44 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.581400E+09 | 45631156.68 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.570702E+09 | 32174948.17 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.498020E+09 | 29251788.97 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.520543E+09 | 27484511.57 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.449726E+09 | 36140562.69 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.481608E+09 | 35008705.58 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.443758E+09 | 32724891.26 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.407696E+09 | 37320104.40 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.381697E+09 | 42423059.01 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.399768E+09 | 56292873.46 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.561878E+10 | 0.478389E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.381697E+09 | 27484511.57 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.581400E+09 | 56292873.46 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_14
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.431574E+09 | 54249153.31 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.452284E+09 | 49687376.44 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.581400E+09 | 45631156.68 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.570702E+09 | 32174948.17 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.498020E+09 | 29251788.97 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.520543E+09 | 27484511.57 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.449726E+09 | 36140562.69 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.481608E+09 | 35008705.58 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.443758E+09 | 32724891.26 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.407696E+09 | 37320104.40 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.381697E+09 | 42423059.01 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.399768E+09 | 56292873.46 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.561878E+10 | 0.478389E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.381697E+09 | 27484511.57 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.581400E+09 | 56292873.46 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_13
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.431574E+09 | 54249153.31 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.452284E+09 | 49687376.44 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.581400E+09 | 45631156.68 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.570702E+09 | 32174948.17 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.498020E+09 | 29251788.97 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.520543E+09 | 27484511.57 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.449726E+09 | 36140562.69 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.481608E+09 | 35008705.58 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.443758E+09 | 32724891.26 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.407696E+09 | 37320104.40 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.381697E+09 | 42423059.01 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.399768E+09 | 56292873.46 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.561878E+10 | 0.478389E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.381697E+09 | 27484511.57 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.581400E+09 | 56292873.46 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_12
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.431574E+09 | 54249153.31 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.452284E+09 | 49687376.44 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.581400E+09 | 45631156.68 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.570702E+09 | 32174948.17 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.498020E+09 | 29251788.97 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.520543E+09 | 27484511.57 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.449726E+09 | 36140562.69 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.481608E+09 | 35008705.58 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.443758E+09 | 32724891.26 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.407696E+09 | 37320104.40 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.381697E+09 | 42423059.01 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.399768E+09 | 56292873.46 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.561878E+10 | 0.478389E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.381697E+09 | 27484511.57 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.581400E+09 | 56292873.46 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_11
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.431574E+09 | 54249153.31 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.452284E+09 | 49687376.44 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.581400E+09 | 45631156.68 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.570702E+09 | 32174948.17 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.498020E+09 | 29251788.97 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.520543E+09 | 27484511.57 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.449726E+09 | 36140562.69 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.481608E+09 | 35008705.58 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.443758E+09 | 32724891.26 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.407696E+09 | 37320104.40 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.381697E+09 | 42423059.01 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.399768E+09 | 56292873.46 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.561878E+10 | 0.478389E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.381697E+09 | 27484511.57 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.581400E+09 | 56292873.46 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R8C1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R8C2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R8C4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R3C4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R3C2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R3C3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R3C1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R4C4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R4C3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R4C2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R4C1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R5C4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R5C1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R5C3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R5C2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R6C1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R6C2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R8C3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R6C4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R7C1
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R7C2
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R7C4
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R6C3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R7C3
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316784E+09 | 0.151527E+09 | 0.165257E+09 | 0.420981E+09 | 69871810.39 |
February | 0.329265E+09 | 0.170314E+09 | 0.158951E+09 | 0.438778E+09 | 66687906.14 |
March | 0.423079E+09 | 0.247518E+09 | 0.175562E+09 | 0.563673E+09 | 65062844.92 |
April | 0.413812E+09 | 0.231030E+09 | 0.182782E+09 | 0.551583E+09 | 50871487.91 |
May | 0.358500E+09 | 0.155277E+09 | 0.203223E+09 | 0.476758E+09 | 49332602.50 |
June | 0.374977E+09 | 0.184972E+09 | 0.190005E+09 | 0.500353E+09 | 46096001.89 |
July | 0.326405E+09 | 0.107785E+09 | 0.218620E+09 | 0.435319E+09 | 52440955.97 |
August | 0.360169E+09 | 0.154025E+09 | 0.206144E+09 | 0.465097E+09 | 51797540.27 |
September | 0.322396E+09 | 0.124814E+09 | 0.197582E+09 | 0.429101E+09 | 49672118.23 |
October | 0.304741E+09 | 0.107763E+09 | 0.196979E+09 | 0.393770E+09 | 55238531.89 |
November | 0.280893E+09 | 0.105802E+09 | 0.175091E+09 | 0.369458E+09 | 58927801.06 |
December | 0.293706E+09 | 0.131677E+09 | 0.162029E+09 | 0.387928E+09 | 73376514.70 |
Annual Sum or Average | 0.410473E+10 | 0.187250E+10 | 0.223222E+10 | 0.543280E+10 | 0.689376E+09 |
Minimum of Months | 0.280893E+09 | 0.105802E+09 | 0.158951E+09 | 0.369458E+09 | 46096001.89 |
Maximum of Months | 0.423079E+09 | 0.247518E+09 | 0.218620E+09 | 0.563673E+09 | 73376514.70 |
Report: WindowZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 395.72 | 95.80 | 214.83 | 58.46 | 156.37 | 0.00 | 0.00 |
February | 444.67 | 82.01 | 233.92 | 64.18 | 169.74 | 0.00 | 0.00 |
March | 503.39 | 67.46 | 257.39 | 80.42 | 176.97 | 0.00 | 0.00 |
April | 518.04 | 43.00 | 263.48 | 79.10 | 184.39 | 0.00 | 0.00 |
May | 505.39 | 44.10 | 249.29 | 59.71 | 189.57 | 0.00 | 0.00 |
June | 563.61 | 46.47 | 279.91 | 83.13 | 196.79 | 0.00 | 0.00 |
July | 451.62 | 64.90 | 239.46 | 45.94 | 193.52 | 0.00 | 0.00 |
August | 448.93 | 59.30 | 240.35 | 55.04 | 185.31 | 0.00 | 0.00 |
September | 416.14 | 58.91 | 218.89 | 45.28 | 173.61 | 0.00 | 0.00 |
October | 375.33 | 69.15 | 206.98 | 39.57 | 167.41 | 0.00 | 0.00 |
November | 364.78 | 75.60 | 200.08 | 40.64 | 159.45 | 0.00 | 0.00 |
December | 368.76 | 102.16 | 201.23 | 50.22 | 151.02 | 0.00 | 0.00 |
Annual Sum or Average | 446.17 | 67.41 | 233.74 | 58.39 | 175.36 | 0.00 | 0.00 |
Minimum of Months | 364.78 | 43.00 | 200.08 | 39.57 | 151.02 | 0.00 | 0.00 |
Maximum of Months | 563.61 | 102.16 | 279.91 | 83.13 | 196.79 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 2255.84 | 283.56 | 1655.83 | 792.03 | 863.80 | 0.00 | 0.00 |
February | 2617.38 | 287.54 | 1905.47 | 985.61 | 919.85 | 0.00 | 0.00 |
March | 3038.98 | 238.51 | 2211.44 | 1293.78 | 917.66 | 0.00 | 0.00 |
April | 3082.50 | 173.78 | 2235.10 | 1247.85 | 987.25 | 0.00 | 0.00 |
May | 2603.15 | 152.90 | 1873.88 | 811.63 | 1062.25 | 0.00 | 0.00 |
June | 2811.58 | 148.45 | 2025.34 | 999.08 | 1026.26 | 0.00 | 0.00 |
July | 2350.72 | 188.91 | 1706.12 | 563.39 | 1142.73 | 0.00 | 0.00 |
August | 2517.36 | 182.99 | 1882.60 | 805.09 | 1077.51 | 0.00 | 0.00 |
September | 2396.84 | 176.75 | 1741.34 | 674.15 | 1067.19 | 0.00 | 0.00 |
October | 2131.03 | 195.07 | 1592.88 | 563.28 | 1029.61 | 0.00 | 0.00 |
November | 2061.64 | 229.14 | 1517.17 | 571.46 | 945.71 | 0.00 | 0.00 |
December | 2089.59 | 294.24 | 1535.20 | 688.28 | 846.93 | 0.00 | 0.00 |
Annual Sum or Average | 2494.38 | 212.37 | 1822.24 | 831.27 | 990.97 | 0.00 | 0.00 |
Minimum of Months | 2061.64 | 148.45 | 1517.17 | 563.28 | 846.93 | 0.00 | 0.00 |
Maximum of Months | 3082.50 | 294.24 | 2235.10 | 1293.78 | 1142.73 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 27179.28 | 3330.24 | 3784.75 | 1810.36 | 1974.39 | 0.00 | 0.00 |
February | 33602.74 | 4318.41 | 4355.35 | 2252.83 | 2102.53 | 0.00 | 0.00 |
March | 38196.07 | 4021.34 | 5054.71 | 2957.20 | 2097.51 | 0.00 | 0.00 |
April | 39767.80 | 3447.60 | 5108.80 | 2852.23 | 2256.57 | 0.00 | 0.00 |
May | 38159.77 | 3149.14 | 4283.15 | 1855.16 | 2427.99 | 0.00 | 0.00 |
June | 39980.65 | 3207.72 | 4629.34 | 2283.60 | 2345.74 | 0.00 | 0.00 |
July | 30100.37 | 3099.75 | 3899.70 | 1287.76 | 2611.94 | 0.00 | 0.00 |
August | 34883.14 | 2945.88 | 4303.09 | 1840.21 | 2462.89 | 0.00 | 0.00 |
September | 31386.23 | 3087.74 | 3980.20 | 1540.91 | 2439.29 | 0.00 | 0.00 |
October | 25886.86 | 2906.73 | 3640.88 | 1287.49 | 2353.39 | 0.00 | 0.00 |
November | 26222.25 | 3131.92 | 3467.81 | 1306.20 | 2161.61 | 0.00 | 0.00 |
December | 24983.81 | 3391.46 | 3509.03 | 1573.20 | 1935.83 | 0.00 | 0.00 |
Annual Sum or Average | 32500.42 | 3329.71 | 4165.12 | 1900.05 | 2265.07 | 0.00 | 0.00 |
Minimum of Months | 24983.81 | 2906.73 | 3467.81 | 1287.49 | 1935.83 | 0.00 | 0.00 |
Maximum of Months | 39980.65 | 4318.41 | 5108.80 | 2957.20 | 2611.94 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.105989E+10 | 0.256587E+09 | 0.575387E+09 | 0.156569E+09 | 0.418818E+09 | 0.00 | 0.00 |
February | 0.107574E+10 | 0.198398E+09 | 0.565902E+09 | 0.155267E+09 | 0.410635E+09 | 0.00 | 0.00 |
March | 0.134828E+10 | 0.180691E+09 | 0.689394E+09 | 0.215387E+09 | 0.474007E+09 | 0.00 | 0.00 |
April | 0.134275E+10 | 0.111462E+09 | 0.682952E+09 | 0.205017E+09 | 0.477934E+09 | 0.00 | 0.00 |
May | 0.135363E+10 | 0.118124E+09 | 0.667687E+09 | 0.159935E+09 | 0.507753E+09 | 0.00 | 0.00 |
June | 0.146089E+10 | 0.120463E+09 | 0.725535E+09 | 0.215466E+09 | 0.510068E+09 | 0.00 | 0.00 |
July | 0.120963E+10 | 0.173826E+09 | 0.641371E+09 | 0.123057E+09 | 0.518314E+09 | 0.00 | 0.00 |
August | 0.120242E+10 | 0.158840E+09 | 0.643751E+09 | 0.147408E+09 | 0.496343E+09 | 0.00 | 0.00 |
September | 0.107864E+10 | 0.152691E+09 | 0.567369E+09 | 0.117364E+09 | 0.450005E+09 | 0.00 | 0.00 |
October | 0.100528E+10 | 0.185207E+09 | 0.554376E+09 | 0.105981E+09 | 0.448396E+09 | 0.00 | 0.00 |
November | 0.945517E+09 | 0.195951E+09 | 0.518620E+09 | 0.105331E+09 | 0.413289E+09 | 0.00 | 0.00 |
December | 0.987677E+09 | 0.273628E+09 | 0.538988E+09 | 0.134508E+09 | 0.404480E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.140704E+11 | 0.212587E+10 | 0.737133E+10 | 0.184129E+10 | 0.553004E+10 | 0.00 | 0.00 |
Minimum of Months | 0.945517E+09 | 0.111462E+09 | 0.518620E+09 | 0.105331E+09 | 0.404480E+09 | 0.00 | 0.00 |
Maximum of Months | 0.146089E+10 | 0.273628E+09 | 0.725535E+09 | 0.215466E+09 | 0.518314E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.604204E+10 | 0.759488E+09 | 0.443497E+10 | 0.212138E+10 | 0.231359E+10 | 0.00 | 0.00 |
February | 0.633197E+10 | 0.695623E+09 | 0.460970E+10 | 0.238439E+10 | 0.222531E+10 | 0.00 | 0.00 |
March | 0.813961E+10 | 0.638836E+09 | 0.592311E+10 | 0.346525E+10 | 0.245786E+10 | 0.00 | 0.00 |
April | 0.798983E+10 | 0.450449E+09 | 0.579337E+10 | 0.323443E+10 | 0.255895E+10 | 0.00 | 0.00 |
May | 0.697228E+10 | 0.409525E+09 | 0.501900E+10 | 0.217387E+10 | 0.284512E+10 | 0.00 | 0.00 |
June | 0.728760E+10 | 0.384783E+09 | 0.524967E+10 | 0.258960E+10 | 0.266007E+10 | 0.00 | 0.00 |
July | 0.629616E+10 | 0.505968E+09 | 0.456967E+10 | 0.150900E+10 | 0.306068E+10 | 0.00 | 0.00 |
August | 0.674251E+10 | 0.490122E+09 | 0.504236E+10 | 0.215635E+10 | 0.288601E+10 | 0.00 | 0.00 |
September | 0.621261E+10 | 0.458148E+09 | 0.451354E+10 | 0.174739E+10 | 0.276615E+10 | 0.00 | 0.00 |
October | 0.570774E+10 | 0.522481E+09 | 0.426638E+10 | 0.150868E+10 | 0.275770E+10 | 0.00 | 0.00 |
November | 0.534376E+10 | 0.593923E+09 | 0.393250E+10 | 0.148123E+10 | 0.245127E+10 | 0.00 | 0.00 |
December | 0.559675E+10 | 0.788100E+09 | 0.411189E+10 | 0.184348E+10 | 0.226841E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.786629E+11 | 0.669745E+10 | 0.574662E+11 | 0.262151E+11 | 0.312511E+11 | 0.00 | 0.00 |
Minimum of Months | 0.534376E+10 | 0.384783E+09 | 0.393250E+10 | 0.148123E+10 | 0.222531E+10 | 0.00 | 0.00 |
Maximum of Months | 0.813961E+10 | 0.788100E+09 | 0.592311E+10 | 0.346525E+10 | 0.306068E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.727970E+11 | 0.891971E+10 | 0.101371E+11 | 0.484886E+10 | 0.528821E+10 | 0.00 | 0.00 |
February | 0.812917E+11 | 0.104471E+11 | 0.105365E+11 | 0.545004E+10 | 0.508643E+10 | 0.00 | 0.00 |
March | 0.102304E+12 | 0.107708E+11 | 0.135385E+11 | 0.792057E+10 | 0.561798E+10 | 0.00 | 0.00 |
April | 0.103078E+12 | 0.893617E+10 | 0.132420E+11 | 0.739298E+10 | 0.584902E+10 | 0.00 | 0.00 |
May | 0.102207E+12 | 0.843465E+10 | 0.114720E+11 | 0.496885E+10 | 0.650314E+10 | 0.00 | 0.00 |
June | 0.103630E+12 | 0.831442E+10 | 0.119993E+11 | 0.591909E+10 | 0.608016E+10 | 0.00 | 0.00 |
July | 0.806208E+11 | 0.830238E+10 | 0.104450E+11 | 0.344914E+10 | 0.699583E+10 | 0.00 | 0.00 |
August | 0.934310E+11 | 0.789026E+10 | 0.115254E+11 | 0.492881E+10 | 0.659660E+10 | 0.00 | 0.00 |
September | 0.813531E+11 | 0.800343E+10 | 0.103167E+11 | 0.399404E+10 | 0.632263E+10 | 0.00 | 0.00 |
October | 0.693354E+11 | 0.778539E+10 | 0.975172E+10 | 0.344841E+10 | 0.630331E+10 | 0.00 | 0.00 |
November | 0.679681E+11 | 0.811794E+10 | 0.898858E+10 | 0.338568E+10 | 0.560290E+10 | 0.00 | 0.00 |
December | 0.669166E+11 | 0.908370E+10 | 0.939860E+10 | 0.421366E+10 | 0.518494E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.102493E+13 | 0.105006E+12 | 0.131351E+12 | 0.599201E+11 | 0.714311E+11 | 0.00 | 0.00 |
Minimum of Months | 0.669166E+11 | 0.778539E+10 | 0.898858E+10 | 0.338568E+10 | 0.508643E+10 | 0.00 | 0.00 |
Maximum of Months | 0.103630E+12 | 0.107708E+11 | 0.135385E+11 | 0.792057E+10 | 0.699583E+10 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 26.42 | 22.38 | 20.70 | 2.25 | 18.66 | 103.85 | 146.57 | 0.01 |
February | 27.50 | 22.91 | 21.01 | 2.37 | 18.54 | 110.59 | 164.59 | 0.00 |
March | 28.33 | 23.63 | 21.77 | 3.67 | 19.85 | 110.33 | 194.39 | 0.01 |
April | 29.15 | 25.37 | 24.04 | 2.98 | 21.51 | 118.69 | 185.56 | 0.03 |
May | 29.01 | 26.53 | 25.72 | 3.19 | 23.00 | 127.71 | 124.87 | 0.08 |
June | 28.86 | 26.50 | 25.74 | 3.10 | 22.78 | 123.38 | 156.09 | 0.05 |
July | 27.25 | 24.29 | 23.20 | 2.32 | 21.53 | 137.39 | 88.28 | 0.02 |
August | 27.54 | 25.86 | 25.31 | 3.22 | 21.55 | 129.55 | 122.00 | 0.07 |
September | 27.58 | 25.59 | 24.93 | 2.22 | 22.01 | 128.30 | 103.37 | 0.04 |
October | 26.89 | 25.07 | 24.46 | 2.18 | 21.39 | 123.79 | 92.41 | 0.11 |
November | 26.68 | 24.14 | 23.20 | 1.94 | 20.29 | 113.70 | 103.30 | 0.02 |
December | 25.97 | 22.85 | 21.57 | 2.00 | 18.63 | 101.83 | 131.96 | 0.00 |
Annual Sum or Average | 27.59 | 24.60 | 23.48 | 2.62 | 20.82 | 119.14 | 134.17 | 0.04 |
Minimum of Months | 25.97 | 22.38 | 20.70 | 1.94 | 18.54 | 101.83 | 88.28 | 0.00 |
Maximum of Months | 29.15 | 26.53 | 25.74 | 3.67 | 23.00 | 137.39 | 194.39 | 0.11 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 34.10 | 04-JAN-12:00 | 23.67 | 19.40 | 5.00 | 24.66 | 266.50 | 576.50 |
February | 35.00 | 21-FEB-13:00 | 22.02 | 16.00 | 2.10 | 24.16 | 230.00 | 672.50 |
March | 36.40 | 21-MAR-12:00 | 23.01 | 17.00 | 5.00 | 26.97 | 269.50 | 658.50 |
April | 35.50 | 01-APR-13:00 | 26.96 | 24.00 | 2.50 | 27.14 | 295.50 | 519.50 |
May | 37.60 | 06-MAY-12:00 | 26.43 | 22.60 | 4.00 | 29.39 | 317.00 | 525.50 |
June | 36.00 | 12-JUN-14:00 | 27.60 | 25.00 | 4.00 | 28.43 | 235.00 | 472.00 |
July | 33.20 | 15-JUL-15:00 | 25.63 | 23.00 | 2.00 | 27.95 | 219.00 | 181.00 |
August | 34.00 | 10-AUG-13:00 | 27.86 | 26.00 | 5.00 | 26.65 | 344.50 | 278.50 |
September | 34.00 | 06-SEP-13:00 | 26.51 | 24.00 | 4.00 | 25.00 | 258.00 | 581.50 |
October | 33.00 | 04-OCT-13:00 | 26.23 | 24.00 | 4.00 | 25.16 | 303.00 | 428.50 |
November | 34.30 | 18-NOV-12:00 | 25.34 | 22.20 | 3.00 | 25.49 | 289.50 | 511.50 |
December | 33.00 | 07-DEC-13:00 | 23.23 | 19.00 | 3.00 | 22.98 | 215.00 | 596.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 33.00 | 22.02 | 16.00 | 2.00 | 22.98 | 215.00 | 181.00 | |
Maximum of Months | 37.60 | 27.86 | 26.00 | 5.00 | 29.39 | 344.50 | 672.50 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 18.70 | 23-JAN-05:00 | 16.92 | 16.00 | 2.00 | 7.75 | 0.00 | 0.00 |
February | 20.30 | 21-FEB-09:00 | 19.04 | 18.40 | 2.00 | 10.50 | 258.50 | 564.00 |
March | 22.00 | 03-MAR-05:00 | 19.94 | 19.00 | 3.00 | 13.35 | 0.00 | 0.00 |
April | 22.90 | 14-APR-15:00 | 22.90 | 22.90 | 3.00 | 14.65 | 199.50 | 264.50 |
May | 22.00 | 10-MAY-19:00 | 22.00 | 22.00 | 2.00 | 18.28 | 0.00 | 0.00 |
June | 23.00 | 20-JUN-23:00 | 23.00 | 23.00 | 2.00 | 19.35 | 0.00 | 0.00 |
July | 23.00 | 13-JUL-04:00 | 22.27 | 22.00 | 0.00 | 13.91 | 0.00 | 0.00 |
August | 22.00 | 20-AUG-10:00 | 22.00 | 22.00 | 5.00 | 18.28 | 430.50 | 41.50 |
September | 22.90 | 19-SEP-03:00 | 22.78 | 22.78 | 0.00 | 21.27 | 0.00 | 0.00 |
October | 22.50 | 23-OCT-04:00 | 22.50 | 22.50 | 2.80 | 18.82 | 0.00 | 0.00 |
November | 20.00 | 25-NOV-04:00 | 18.63 | 18.00 | 2.00 | 10.69 | 0.00 | 0.00 |
December | 18.00 | 21-DEC-04:00 | 17.36 | 17.00 | 3.00 | 9.13 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 18.00 | 16.92 | 16.00 | 0.00 | 7.75 | 0.00 | 0.00 | |
Maximum of Months | 23.00 | 23.00 | 23.00 | 5.00 | 21.27 | 430.50 | 564.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 25.53 | 12-JAN-12:00 | 32.40 | 23.10 | 2.00 | 25.00 | 353.00 | 347.00 |
February | 26.17 | 14-FEB-15:00 | 32.30 | 24.20 | 2.00 | 25.16 | 200.00 | 199.00 |
March | 26.28 | 27-MAR-12:00 | 34.20 | 23.60 | 4.00 | 26.32 | 326.00 | 535.00 |
April | 27.93 | 10-APR-16:49 | 31.52 | 26.85 | 4.08 | 27.70 | 110.67 | 57.00 |
May | 29.00 | 28-MAY-20:00 | 29.00 | 29.00 | 3.00 | 22.47 | 0.00 | 0.00 |
June | 30.11 | 15-JUN-09:00 | 33.20 | 29.20 | 5.00 | 26.48 | 320.50 | 421.00 |
July | 26.43 | 20-JUL-14:00 | 32.80 | 24.20 | 1.00 | 26.65 | 305.00 | 253.00 |
August | 28.81 | 14-AUG-16:00 | 32.00 | 28.00 | 1.00 | 25.16 | 107.50 | 223.00 |
September | 30.06 | 30-SEP-10:00 | 32.80 | 29.40 | 3.00 | 25.66 | 398.00 | 359.50 |
October | 27.36 | 16-OCT-14:00 | 31.50 | 26.00 | 3.00 | 24.16 | 239.00 | 346.50 |
November | 27.56 | 10-NOV-12:00 | 31.00 | 26.40 | 6.00 | 28.11 | 388.00 | 95.50 |
December | 26.86 | 03-DEC-12:00 | 31.50 | 25.30 | 1.00 | 23.49 | 301.00 | 468.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 25.53 | 29.00 | 23.10 | 1.00 | 22.47 | 0.00 | 0.00 | |
Maximum of Months | 30.11 | 34.20 | 29.40 | 6.00 | 28.11 | 398.00 | 535.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 24.20 | 09-JAN-21:00 | 26.50 | 24.77 | 4.00 | 25.16 | 0.00 | 0.00 |
February | 24.40 | 15-FEB-18:00 | 28.30 | 25.33 | 4.00 | 20.75 | 0.00 | 0.00 |
March | 25.30 | 28-MAR-06:00 | 27.20 | 25.72 | 3.00 | 19.87 | 103.00 | 28.00 |
April | 27.00 | 10-APR-17:00 | 30.50 | 27.87 | 4.50 | 25.00 | 20.00 | 20.50 |
May | 29.00 | 28-MAY-20:00 | 29.00 | 29.00 | 3.00 | 22.47 | 0.00 | 0.00 |
June | 29.20 | 15-JUN-09:00 | 33.20 | 30.11 | 5.00 | 26.48 | 320.50 | 421.00 |
July | 26.00 | 10-JUL-14:00 | 26.50 | 26.11 | 2.30 | 23.49 | 286.00 | 36.50 |
August | 28.00 | 02-AUG-10:00 | 31.00 | 28.65 | 4.00 | 24.16 | 419.00 | 195.50 |
September | 29.40 | 30-SEP-10:00 | 32.80 | 30.06 | 3.00 | 25.66 | 398.00 | 359.50 |
October | 26.50 | 16-OCT-08:00 | 29.00 | 27.04 | 2.50 | 21.78 | 300.00 | 326.00 |
November | 26.40 | 10-NOV-12:00 | 31.00 | 27.56 | 6.00 | 28.11 | 388.00 | 95.50 |
December | 26.00 | 10-DEC-17:00 | 29.00 | 26.74 | 3.00 | 21.78 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 24.20 | 26.50 | 24.77 | 2.30 | 19.87 | 0.00 | 0.00 | |
Maximum of Months | 29.40 | 33.20 | 30.11 | 6.00 | 28.11 | 419.00 | 421.00 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 29.71 | 38.82 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 29.90 | 44.34 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 30.35 | 50.49 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 30.97 | 51.18 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 31.58 | 43.47 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 32.02 | 46.77 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 32.16 | 39.95 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 31.97 | 43.65 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 31.50 | 40.53 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 30.87 | 37.35 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 30.27 | 35.77 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 29.84 | 36.19 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 30.93 | 42.35 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 29.71 | 35.77 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 32.16 | 51.18 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.592256E+09 | -522968806.0 | 0.00 | 0.00 | 744.00 | 0.00 | -69287209.9 | 58.99 | 0.00 | 0.00 |
February | 0.539853E+09 | -477410880.2 | 0.00 | 0.00 | 672.00 | 0.00 | -62442146.5 | 58.99 | 0.00 | 0.00 |
March | 0.618430E+09 | -549156614.2 | 0.00 | 0.00 | 744.00 | 0.00 | -69273289.6 | 58.99 | 0.00 | 0.00 |
April | 0.565699E+09 | -499172259.8 | 0.00 | 0.00 | 720.00 | 0.00 | -66526928.7 | 58.98 | 0.00 | 0.00 |
May | 0.576555E+09 | -507768585.6 | 0.00 | 0.00 | 744.00 | 0.00 | -68786379.0 | 58.99 | 0.00 | 0.00 |
June | 0.564933E+09 | -498265411.1 | 0.00 | 0.00 | 720.00 | 0.00 | -66667130.6 | 59.00 | 0.00 | 0.00 |
July | 0.547893E+09 | -479125219.5 | 0.00 | 0.00 | 744.00 | 0.00 | -68767795.5 | 58.99 | 0.00 | 0.00 |
August | 0.587571E+09 | -518277466.9 | 0.00 | 0.00 | 744.00 | 0.00 | -69293244.6 | 58.98 | 0.00 | 0.00 |
September | 0.556872E+09 | -490096840.6 | 0.00 | 0.00 | 720.00 | 0.00 | -66775603.6 | 58.99 | 0.00 | 0.00 |
October | 0.571338E+09 | -502265981.6 | 0.00 | 0.00 | 744.00 | 0.00 | -69072414.6 | 58.99 | 0.00 | 0.00 |
November | 0.559668E+09 | -492733945.0 | 0.00 | 0.00 | 720.00 | 0.00 | -66934226.2 | 58.99 | 0.00 | 0.00 |
December | 0.590004E+09 | -520533729.6 | 0.00 | 0.00 | 744.00 | 0.00 | -69470367.2 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.687107E+10 | -0.605778E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -813296735.9 | 58.99 | 0.00 | 0.00 |
Minimum of Months | 0.539853E+09 | -549156614.2 | 0.00 | 0.00 | 672.00 | 0.00 | -69470367.2 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.618430E+09 | -477410880.2 | 0.00 | 0.00 | 744.00 | 0.00 | -62442146.5 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: ZONE2 FINE STORAGE_DAYLCTRL
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 350.67 | 0.65 | 0.50 | 01-JAN-09:50 | 418.81 | 0.00 | 0.00 | 218.00 | 341.98 | 0.00 | 0.00 | 182.83 |
February | 321.17 | 0.64 | 0.50 | 01-FEB-09:30 | 450.25 | 0.00 | 0.00 | 207.50 | 370.28 | 0.00 | 0.00 | 176.50 |
March | 361.17 | 0.63 | 0.50 | 01-MAR-09:09 | 1150.70 | 0.00 | 0.00 | 239.00 | 2023.49 | 0.00 | 0.00 | 195.83 |
April | 358.33 | 0.64 | 0.50 | 01-APR-09:30 | 1169.33 | 0.00 | 0.00 | 238.83 | 341.94 | 0.00 | 0.00 | 181.33 |
May | 376.33 | 0.65 | 0.50 | 01-MAY-09:30 | 516.95 | 0.00 | 0.00 | 253.33 | 294.47 | 0.00 | 0.00 | 170.33 |
June | 370.50 | 0.65 | 0.50 | 01-JUN-09:20 | 504.19 | 0.00 | 0.00 | 247.17 | 272.08 | 0.00 | 0.00 | 157.50 |
July | 383.17 | 0.65 | 0.50 | 01-JUL-09:30 | 521.07 | 0.00 | 0.00 | 255.00 | 288.33 | 0.00 | 0.00 | 170.00 |
August | 369.33 | 0.63 | 0.50 | 01-AUG-09:30 | 625.17 | 0.00 | 0.00 | 254.67 | 335.00 | 0.00 | 0.00 | 187.83 |
September | 357.83 | 0.64 | 0.50 | 01-SEP-08:50 | 1264.19 | 0.00 | 0.00 | 239.67 | 938.46 | 0.00 | 0.00 | 190.33 |
October | 356.83 | 0.63 | 0.50 | 01-OCT-08:50 | 513.01 | 0.00 | 0.00 | 238.33 | 887.84 | 0.00 | 0.00 | 197.50 |
November | 337.67 | 0.64 | 0.50 | 01-NOV-08:39 | 459.96 | 0.00 | 0.00 | 218.33 | 369.62 | 0.00 | 0.00 | 182.17 |
December | 349.33 | 0.65 | 0.50 | 01-DEC-08:39 | 978.41 | 0.00 | 0.00 | 213.33 | 332.99 | 0.00 | 0.00 | 181.50 |
Annual Sum or Average | 4292.33 | 0.64 | 715.35 | 0.00 | 0.00 | 2823.17 | 566.54 | 0.00 | 0.00 | 2173.67 | ||
Minimum of Months | 321.17 | 0.63 | 0.50 | 418.81 | 0.00 | 0.00 | 207.50 | 272.08 | 0.00 | 0.00 | 157.50 | |
Maximum of Months | 383.17 | 0.65 | 0.50 | 1264.19 | 0.00 | 0.00 | 255.00 | 2023.49 | 0.00 | 0.00 | 197.50 |
Report: DaylightingReportMonthly
For: ZONE3 BULK STORAGE_DAYLCTRL
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 350.67 | 0.58 | 0.50 | 01-JAN-07:49 | 471.48 | 16.25 | 2.33 | 278.67 | 399.23 | 19.98 | 149.67 | 253.33 |
February | 321.17 | 0.58 | 0.50 | 01-FEB-07:40 | 511.27 | 16.39 | 18.33 | 261.67 | 436.22 | 20.23 | 136.83 | 240.00 |
March | 361.17 | 0.57 | 0.50 | 01-MAR-07:40 | 1748.65 | 16.62 | 36.33 | 300.67 | 2979.50 | 22.00 | 145.33 | 274.17 |
April | 358.33 | 0.56 | 0.50 | 01-APR-07:10 | 544.56 | 16.86 | 45.33 | 298.83 | 466.03 | 20.83 | 148.17 | 272.33 |
May | 376.33 | 0.57 | 0.50 | 01-MAY-06:00 | 555.68 | 16.68 | 32.33 | 309.50 | 483.95 | 20.32 | 139.00 | 287.00 |
June | 370.50 | 0.57 | 0.50 | 01-JUN-07:19 | 2269.31 | 17.84 | 71.17 | 302.83 | 488.05 | 20.61 | 151.00 | 280.00 |
July | 383.17 | 0.57 | 0.50 | 01-JUL-06:00 | 557.93 | 16.45 | 28.17 | 309.17 | 493.79 | 19.93 | 139.67 | 285.83 |
August | 369.33 | 0.56 | 0.50 | 01-AUG-07:10 | 577.00 | 16.93 | 43.50 | 307.50 | 502.95 | 20.60 | 144.33 | 286.67 |
September | 357.83 | 0.57 | 0.50 | 01-SEP-06:00 | 556.16 | 16.37 | 33.67 | 289.17 | 510.23 | 21.21 | 152.83 | 274.50 |
October | 356.83 | 0.57 | 0.50 | 01-OCT-06:00 | 1036.51 | 17.64 | 62.83 | 289.17 | 514.16 | 20.99 | 149.00 | 272.67 |
November | 337.67 | 0.57 | 0.50 | 01-NOV-07:10 | 511.96 | 16.76 | 7.83 | 271.67 | 435.87 | 20.37 | 143.17 | 250.33 |
December | 349.33 | 0.58 | 0.50 | 01-DEC-07:19 | 460.33 | 16.20 | 0.17 | 273.17 | 387.99 | 19.88 | 146.17 | 250.00 |
Annual Sum or Average | 4292.33 | 0.57 | 823.69 | 16.76 | 382.00 | 3492.00 | 677.92 | 20.58 | 1745.17 | 3226.83 | ||
Minimum of Months | 321.17 | 0.56 | 0.50 | 460.33 | 16.20 | 0.17 | 261.67 | 387.99 | 19.88 | 136.83 | 240.00 | |
Maximum of Months | 383.17 | 0.58 | 0.50 | 2269.31 | 17.84 | 71.17 | 309.50 | 2979.50 | 22.00 | 152.83 | 287.00 |
Report: DaylightingReportMonthly
For: ZONE1 OFFICE_DAYLCTRL
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 350.67 | 0.88 | 0.80 | 05-JAN-15:30 | 298.92 | 23.48 | 197.17 | 72.17 | 176.02 | 22.44 | 204.33 | 11.83 |
February | 321.17 | 0.88 | 0.80 | 01-FEB-16:10 | 331.55 | 23.57 | 173.33 | 86.00 | 234.86 | 24.07 | 198.67 | 38.00 |
March | 361.17 | 0.87 | 0.80 | 02-MAR-14:20 | 339.78 | 22.88 | 181.67 | 99.50 | 274.21 | 23.72 | 222.50 | 70.00 |
April | 358.33 | 0.87 | 0.80 | 01-APR-14:09 | 294.88 | 21.32 | 158.50 | 89.50 | 266.64 | 22.57 | 224.67 | 65.83 |
May | 376.33 | 0.87 | 0.80 | 01-MAY-14:09 | 288.90 | 20.31 | 131.33 | 79.17 | 214.26 | 21.66 | 193.50 | 41.67 |
June | 370.50 | 0.86 | 0.80 | 01-JUN-14:20 | 322.61 | 20.75 | 142.50 | 115.17 | 252.65 | 22.19 | 224.17 | 46.17 |
July | 383.17 | 0.87 | 0.80 | 02-JUL-16:10 | 276.51 | 19.80 | 115.17 | 65.17 | 200.18 | 21.15 | 164.50 | 31.50 |
August | 369.33 | 0.87 | 0.80 | 01-AUG-14:20 | 287.80 | 20.65 | 135.50 | 73.50 | 226.63 | 21.94 | 201.67 | 53.50 |
September | 357.83 | 0.88 | 0.80 | 02-SEP-14:09 | 252.32 | 20.23 | 131.17 | 47.17 | 190.47 | 22.24 | 194.33 | 30.67 |
October | 356.83 | 0.88 | 0.80 | 02-OCT-13:00 | 257.87 | 22.39 | 173.00 | 53.50 | 168.24 | 23.45 | 207.33 | 18.67 |
November | 337.67 | 0.89 | 0.80 | 02-NOV-14:20 | 254.80 | 23.00 | 188.50 | 45.83 | 153.04 | 22.58 | 194.83 | 6.67 |
December | 349.33 | 0.89 | 0.80 | 03-DEC-15:09 | 262.01 | 22.97 | 193.83 | 68.00 | 141.43 | 21.38 | 192.33 | 0.00 |
Annual Sum or Average | 4292.33 | 0.88 | 288.90 | 21.73 | 1921.67 | 894.67 | 208.66 | 22.42 | 2422.83 | 414.50 | ||
Minimum of Months | 321.17 | 0.86 | 0.80 | 252.32 | 19.80 | 115.17 | 45.83 | 141.43 | 21.15 | 164.50 | 0.00 | |
Maximum of Months | 383.17 | 0.89 | 0.80 | 339.78 | 23.57 | 197.17 | 115.17 | 274.21 | 24.07 | 224.67 | 70.00 |
Report: CoilReportMonthly
For: PSZ-OFFICE HEATING COIL
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE HEATING COIL
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.128875E+11 | 0.906282E+10 | 32127.57 | 02-JAN-07:01 | 16034.85 | 0.00 |
February | 0.00 | 0.00 | 0.124936E+11 | 0.886080E+10 | 31545.05 | 16-FEB-07:01 | 16416.77 | 0.00 |
March | 0.00 | 0.00 | 0.157985E+11 | 0.109329E+11 | 31809.41 | 15-MAR-06:02 | 16225.18 | 0.00 |
April | 0.00 | 0.00 | 0.161094E+11 | 0.104418E+11 | 31791.16 | 24-APR-06:01 | 16690.27 | 0.00 |
May | 0.00 | 0.00 | 0.181910E+11 | 0.109294E+11 | 32088.05 | 09-MAY-06:01 | 16064.15 | 0.00 |
June | 0.00 | 0.00 | 0.185517E+11 | 0.111738E+11 | 32127.57 | 21-JUN-06:01 | 14889.92 | 0.00 |
July | 0.00 | 0.00 | 0.146426E+11 | 0.947349E+10 | 31871.76 | 24-JUL-06:01 | 16679.17 | 0.00 |
August | 0.00 | 0.00 | 0.176936E+11 | 0.103517E+11 | 32042.46 | 04-AUG-06:03 | 14208.76 | 0.00 |
September | 0.00 | 0.00 | 0.157241E+11 | 0.953578E+10 | 32060.69 | 19-SEP-06:01 | 15897.73 | 0.00 |
October | 0.00 | 0.00 | 0.148306E+11 | 0.895679E+10 | 32127.57 | 23-OCT-06:01 | 14760.18 | 0.00 |
November | 0.00 | 0.00 | 0.135604E+11 | 0.866915E+10 | 31800.94 | 03-NOV-06:01 | 16222.61 | 0.00 |
December | 0.00 | 0.00 | 0.126549E+11 | 0.869977E+10 | 31839.23 | 11-DEC-07:01 | 16371.18 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.183138E+12 | 0.117088E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.124936E+11 | 0.866915E+10 | 31545.05 | 14208.76 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.185517E+11 | 0.111738E+11 | 32127.57 | 16690.27 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.302150E+11 | 0.200103E+11 | 84281.07 | 11-JAN-07:01 | 44269.85 | 0.00 |
February | 0.00 | 0.00 | 0.325616E+11 | 0.218389E+11 | 78154.62 | 17-FEB-18:10 | 50352.34 | 0.00 |
March | 0.00 | 0.00 | 0.433536E+11 | 0.281921E+11 | 81935.62 | 23-MAR-06:01 | 47406.95 | 0.00 |
April | 0.00 | 0.00 | 0.481061E+11 | 0.290578E+11 | 83345.33 | 13-APR-06:01 | 46593.38 | 0.00 |
May | 0.00 | 0.00 | 0.520798E+11 | 0.288599E+11 | 85879.89 | 25-MAY-06:01 | 42205.98 | 0.00 |
June | 0.00 | 0.00 | 0.542656E+11 | 0.301000E+11 | 85927.41 | 02-JUN-06:01 | 42107.99 | 0.00 |
July | 0.00 | 0.00 | 0.383168E+11 | 0.231282E+11 | 81880.32 | 31-JUL-17:10 | 47170.86 | 0.00 |
August | 0.00 | 0.00 | 0.442188E+11 | 0.232921E+11 | 89117.35 | 04-AUG-06:01 | 36344.43 | 0.00 |
September | 0.00 | 0.00 | 0.409920E+11 | 0.228564E+11 | 88131.33 | 21-SEP-06:01 | 39979.73 | 0.00 |
October | 0.00 | 0.00 | 0.354588E+11 | 0.195606E+11 | 89193.43 | 14-OCT-06:01 | 37899.53 | 0.00 |
November | 0.00 | 0.00 | 0.318850E+11 | 0.188570E+11 | 84342.56 | 22-NOV-07:01 | 45679.97 | 0.00 |
December | 0.00 | 0.00 | 0.288893E+11 | 0.184099E+11 | 86858.88 | 12-DEC-07:01 | 42582.69 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.480342E+12 | 0.284163E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.288893E+11 | 0.184099E+11 | 78154.62 | 36344.43 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.542656E+11 | 0.301000E+11 | 89193.43 | 50352.34 | 0.00 |
Report: FanReportMonthly
For: ZONE3UNITHEATER ZONE3HIRADIANT FAN
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:03 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 |
Report: FanReportMonthly
For: PSZ-OFFICE_ADDAQ SUPPLY FAN
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.578867E+09 | 0.22 | 1289.00 | 02-JAN-07:01 | 0.89 |
February | 0.566418E+09 | 0.24 | 1289.00 | 01-FEB-07:02 | 0.89 |
March | 0.710193E+09 | 0.26 | 1289.00 | 01-MAR-07:01 | 0.89 |
April | 0.716641E+09 | 0.27 | 1289.00 | 01-APR-06:01 | 0.89 |
May | 0.799221E+09 | 0.28 | 1289.00 | 01-MAY-05:02 | 0.88 |
June | 0.821613E+09 | 0.29 | 1289.00 | 01-JUN-06:01 | 0.89 |
July | 0.633823E+09 | 0.24 | 1289.00 | 01-JUL-06:01 | 0.89 |
August | 0.760151E+09 | 0.27 | 1289.00 | 01-AUG-06:01 | 0.89 |
September | 0.677126E+09 | 0.25 | 1289.00 | 01-SEP-06:01 | 0.89 |
October | 0.631180E+09 | 0.23 | 1289.00 | 02-OCT-06:01 | 0.89 |
November | 0.585694E+09 | 0.23 | 1289.00 | 01-NOV-06:01 | 0.89 |
December | 0.564153E+09 | 0.22 | 1289.00 | 01-DEC-07:02 | 0.89 |
Annual Sum or Average | 0.804508E+10 | 0.25 | |||
Minimum of Months | 0.564153E+09 | 0.22 | 1289.00 | 0.88 | |
Maximum of Months | 0.821613E+09 | 0.29 | 1289.00 | 0.89 |
Report: FanReportMonthly
For: PSZ-FINE STORAGE_ADDAQ SUPPLY FAN
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.137907E+10 | 0.29 | 2950.28 | 08-JAN-11:33 | 0.87 |
February | 0.134527E+10 | 0.33 | 2950.28 | 05-FEB-10:23 | 0.87 |
March | 0.166960E+10 | 0.36 | 2950.28 | 05-MAR-10:13 | 0.86 |
April | 0.171335E+10 | 0.40 | 2950.28 | 01-APR-17:06 | 0.86 |
May | 0.181483E+10 | 0.39 | 2950.28 | 01-MAY-17:06 | 0.86 |
June | 0.186372E+10 | 0.41 | 2950.28 | 01-JUN-17:10 | 0.86 |
July | 0.154597E+10 | 0.36 | 2950.28 | 02-JUL-10:23 | 0.86 |
August | 0.164043E+10 | 0.35 | 2950.28 | 01-AUG-17:06 | 0.86 |
September | 0.154947E+10 | 0.36 | 2950.28 | 02-SEP-06:01 | 0.86 |
October | 0.146460E+10 | 0.32 | 2950.28 | 01-OCT-10:43 | 0.86 |
November | 0.135865E+10 | 0.30 | 2950.28 | 05-NOV-09:53 | 0.86 |
December | 0.136230E+10 | 0.28 | 2950.28 | 03-DEC-11:03 | 0.87 |
Annual Sum or Average | 0.187073E+11 | 0.35 | |||
Minimum of Months | 0.134527E+10 | 0.28 | 2950.28 | 0.86 | |
Maximum of Months | 0.186372E+10 | 0.41 | 2950.28 | 0.87 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-OFFICE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.363763E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.357372E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.454749E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.461176E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.515915E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.527841E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.405203E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.488016E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.434971E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.405163E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.373919E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.353812E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.514190E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.353812E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.527841E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.884079E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.941344E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.123952E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.134657E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.143929E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.149153E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.107977E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.120877E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.113267E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.990061E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.904143E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.844548E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.135023E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.844548E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.149153E+11 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-OFFICE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.578867E+09 | 0.128875E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.566418E+09 | 0.124936E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.710193E+09 | 0.157985E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.716641E+09 | 0.161094E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.799221E+09 | 0.181910E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.821613E+09 | 0.185517E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.633823E+09 | 0.146426E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.760151E+09 | 0.176936E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.677126E+09 | 0.157241E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.631180E+09 | 0.148306E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.585694E+09 | 0.135604E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.564153E+09 | 0.126549E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.804508E+10 | 0.183138E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.564153E+09 | 0.124936E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.821613E+09 | 0.185517E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-FINE STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.137907E+10 | 0.302150E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.134527E+10 | 0.325616E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.166960E+10 | 0.433536E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.171335E+10 | 0.481061E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.181483E+10 | 0.520798E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.186372E+10 | 0.542656E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.154597E+10 | 0.383168E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.164043E+10 | 0.442188E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.154947E+10 | 0.409920E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.146460E+10 | 0.354588E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.135865E+10 | 0.318850E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.136230E+10 | 0.288893E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.187073E+11 | 0.480342E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.134527E+10 | 0.288893E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.186372E+10 | 0.542656E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-OFFICE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.578867E+09 | 0.00 | 0.00 | 0.00 | 0.305876E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.566418E+09 | 0.00 | 0.00 | 0.00 | 0.300730E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.710193E+09 | 0.00 | 0.00 | 0.00 | 0.383729E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.716641E+09 | 0.00 | 0.00 | 0.00 | 0.389512E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.799221E+09 | 0.00 | 0.00 | 0.00 | 0.435993E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.821613E+09 | 0.00 | 0.00 | 0.00 | 0.445679E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.633823E+09 | 0.00 | 0.00 | 0.00 | 0.341820E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.760151E+09 | 0.00 | 0.00 | 0.00 | 0.412000E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.677126E+09 | 0.00 | 0.00 | 0.00 | 0.367258E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.631180E+09 | 0.00 | 0.00 | 0.00 | 0.342045E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.585694E+09 | 0.00 | 0.00 | 0.00 | 0.315349E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.564153E+09 | 0.00 | 0.00 | 0.00 | 0.297397E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.804508E+10 | 0.00 | 0.00 | 0.00 | 0.433739E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.564153E+09 | 0.00 | 0.00 | 0.00 | 0.297397E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.821613E+09 | 0.00 | 0.00 | 0.00 | 0.445679E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.137907E+10 | 0.00 | 0.00 | 0.00 | 0.746172E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.134527E+10 | 0.00 | 0.00 | 0.00 | 0.806818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.166960E+10 | 0.00 | 0.00 | 0.00 | 0.107256E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.171335E+10 | 0.00 | 0.00 | 0.00 | 0.117524E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.181483E+10 | 0.00 | 0.00 | 0.00 | 0.125781E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.186372E+10 | 0.00 | 0.00 | 0.00 | 0.130516E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.154597E+10 | 0.00 | 0.00 | 0.00 | 0.925173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.164043E+10 | 0.00 | 0.00 | 0.00 | 0.104473E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.154947E+10 | 0.00 | 0.00 | 0.00 | 0.977727E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.146460E+10 | 0.00 | 0.00 | 0.00 | 0.843600E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.135865E+10 | 0.00 | 0.00 | 0.00 | 0.768278E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.136230E+10 | 0.00 | 0.00 | 0.00 | 0.708317E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.187073E+11 | 0.00 | 0.00 | 0.00 | 0.116316E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.134527E+10 | 0.00 | 0.00 | 0.00 | 0.708317E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.186372E+10 | 0.00 | 0.00 | 0.00 | 0.130516E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 2584876.05 | 0.206406E+10 | 0.00 | 933165.65 | 4499857.00 | 0.00 | 9613767.48 | 0.00 | 0.14 |
February | 1487850.85 | 0.206549E+10 | 0.00 | 773743.47 | 5103209.06 | 0.00 | 4293264.39 | 0.00 | 0.14 |
March | 25902.25 | 0.268273E+10 | 0.00 | 344450.42 | 7532774.00 | 0.00 | 365176.75 | 0.00 | 0.15 |
April | 0.00 | 0.316559E+10 | 0.00 | 18574.95 | 8908067.42 | 0.00 | 30501.00 | 0.00 | 0.15 |
May | 0.00 | 0.381904E+10 | 0.00 | 137323.63 | 6676353.38 | 0.00 | 76732.59 | 0.00 | 0.15 |
June | 0.00 | 0.397311E+10 | 0.00 | 99508.42 | 6668809.58 | 0.00 | 0.00 | 0.00 | 0.15 |
July | 0.00 | 0.271842E+10 | 0.00 | 42923.39 | 9819606.74 | 0.00 | 159671.55 | 0.00 | 0.14 |
August | 0.00 | 0.373813E+10 | 0.00 | 106876.39 | 8844854.43 | 0.00 | 161423.31 | 0.00 | 0.15 |
September | 0.00 | 0.333144E+10 | 0.00 | 8938.77 | 10317897.72 | 0.00 | 0.00 | 0.00 | 0.15 |
October | 0.00 | 0.303903E+10 | 0.00 | 191147.12 | 8869313.29 | 0.00 | 173447.64 | 0.00 | 0.14 |
November | 372494.71 | 0.255095E+10 | 0.00 | 502320.02 | 6644263.82 | 0.00 | 1579950.96 | 0.00 | 0.14 |
December | 2249372.72 | 0.217593E+10 | 0.00 | 707703.50 | 5142514.12 | 0.00 | 3064356.36 | 0.00 | 0.14 |
Annual Sum or Average | 6720496.59 | 0.353239E+11 | 0.00 | 3866675.73 | 89027520.56 | 0.00 | 19518292.03 | 0.00 | 0.14 |
Minimum of Months | 0.00 | 0.206406E+10 | 0.00 | 8938.77 | 4499857.00 | 0.00 | 0.00 | 0.00 | 0.14 |
Maximum of Months | 2584876.05 | 0.397311E+10 | 0.00 | 933165.65 | 10317897.72 | 0.00 | 9613767.48 | 0.00 | 0.15 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 27890215.00 | 0.644004E+10 | 0.00 | 1121604.37 | 8557961.02 | 0.00 | 89675310.92 | 0.00 | 0.22 |
February | 3837707.95 | 0.731490E+10 | 0.00 | 722740.41 | 10603920.80 | 0.00 | 26263352.05 | 0.00 | 0.23 |
March | 382635.89 | 0.960438E+10 | 0.00 | 200428.83 | 13403938.75 | 0.00 | 4731670.44 | 0.00 | 0.25 |
April | 0.00 | 0.128771E+11 | 0.00 | 0.00 | 15431272.05 | 0.00 | 0.00 | 0.00 | 0.26 |
May | 0.00 | 0.153994E+11 | 0.00 | 0.00 | 19582530.32 | 0.00 | 0.00 | 0.00 | 0.26 |
June | 0.00 | 0.163611E+11 | 0.00 | 0.00 | 18543135.10 | 0.00 | 0.00 | 0.00 | 0.27 |
July | 0.00 | 0.996743E+10 | 0.00 | 0.00 | 31256210.36 | 0.00 | 0.00 | 0.00 | 0.24 |
August | 0.00 | 0.132725E+11 | 0.00 | 50079.23 | 21058442.47 | 0.00 | 62697.57 | 0.00 | 0.25 |
September | 0.00 | 0.124665E+11 | 0.00 | 0.00 | 22449511.36 | 0.00 | 0.00 | 0.00 | 0.25 |
October | 351501.43 | 0.103580E+11 | 0.00 | 81635.63 | 21280094.99 | 0.00 | 2063609.68 | 0.00 | 0.23 |
November | 1467358.44 | 0.871855E+10 | 0.00 | 242595.94 | 11901039.70 | 0.00 | 16500261.28 | 0.00 | 0.22 |
December | 14905174.23 | 0.676275E+10 | 0.00 | 835675.28 | 9702064.55 | 0.00 | 76364301.90 | 0.00 | 0.22 |
Annual Sum or Average | 48834592.94 | 0.129543E+12 | 0.00 | 3254759.68 | 0.203770E+09 | 0.00 | 0.215661E+09 | 0.00 | 0.24 |
Minimum of Months | 0.00 | 0.644004E+10 | 0.00 | 0.00 | 8557961.02 | 0.00 | 0.00 | 0.00 | 0.22 |
Maximum of Months | 27890215.00 | 0.163611E+11 | 0.00 | 1121604.37 | 31256210.36 | 0.00 | 89675310.92 | 0.00 | 0.27 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 10:43:49
Custom Monthly ReportSITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
January | 0.557489E+12 | 0.198523E+11 | 0.00 | -0.122573E+11 | 0.536230E+11 |
February | 0.547750E+12 | 0.226518E+11 | 0.00 | -0.142552E+11 | 0.561306E+11 |
March | 0.708222E+12 | 0.297159E+11 | 0.00 | -0.174735E+11 | 0.737150E+11 |
April | 0.702305E+12 | 0.281962E+11 | 0.00 | -0.237008E+11 | 0.798630E+11 |
May | 0.692333E+12 | 0.252579E+11 | 0.00 | -0.284008E+11 | 0.872088E+11 |
June | 0.717200E+12 | 0.305618E+11 | 0.00 | -0.288557E+11 | 0.903256E+11 |
July | 0.598051E+12 | 0.260468E+11 | 0.00 | -0.210824E+11 | 0.656293E+11 |
August | 0.739390E+12 | 0.250064E+11 | 0.00 | -0.245072E+11 | 0.764798E+11 |
September | 0.587560E+12 | 0.252111E+11 | 0.00 | -0.247688E+11 | 0.701659E+11 |
October | 0.634520E+12 | 0.241806E+11 | 0.00 | -0.219836E+11 | 0.621458E+11 |
November | 0.528933E+12 | 0.231311E+11 | 0.00 | -0.183260E+11 | 0.562816E+11 |
December | 0.525855E+12 | 0.247935E+11 | 0.00 | -0.132747E+11 | 0.516013E+11 |
Annual Sum or Average | 0.753961E+13 | 0.304605E+12 | 0.00 | -0.248886E+12 | 0.823170E+12 |
Minimum of Months | 0.525855E+12 | 0.198523E+11 | 0.00 | -0.288557E+11 | 0.516013E+11 |