Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 10:43
Tabular Output Report in Format: HTML
Building: Warehouse
Environment: RUNPERIOD 1 ** Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695
Simulation Timestamp: 2023-10-16 10:43:46
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 843.26 | 174.40 | 174.40 |
Net Site Energy | 843.26 | 174.40 | 174.40 |
Total Source Energy | 1881.41 | 389.11 | 389.11 |
Net Source Energy | 1881.41 | 389.11 | 389.11 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 1.200 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil No 1 | 1.050 |
Fuel Oil No 2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4835.13 |
Net Conditioned Building Area | 4835.13 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 378.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 16.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 157.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 92.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 139.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 31.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 26.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 464.39 | 378.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 378.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 16.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 157.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 92.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 139.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 3.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 28.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 26.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Unassigned | 0.00 | 378.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | Unassigned | 16.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GENERAL | 157.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | Unassigned | 92.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | GENERAL | 139.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Unassigned | 31.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Unassigned | 26.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 51.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 15.46 | 78.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 96.04 | 78.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 51.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 15.46 | 78.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 96.04 | 78.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 464.387 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 464.387 | 100.00 |
Total On-Site and Utility Electric Sources | 464.387 | 100.00 |
Total Electricity End Uses | 464.387 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 51.61 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 51.61 | 100.00 |
Total Water End Uses | 51.61 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 33.67 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 3128.00 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5B
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_CO_DENVER
| Environment |ZoneCoolingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneHeatingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneElectricSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |PeakSpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainComponentsAtCoolingPeakMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ComfortReportSimple55Monthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |OccupantComfortDataSummaryMonthly
| OFFICE PEOPLE | ZONE2 FINE STORAGEPEOPLE | ZONE3 BULK STORAGEPEOPLE |DXReportMonthly
| PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |WindowReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | FINESTORAGE_SKYLIGHT_1 | FINESTORAGE_SKYLIGHT_6 | FINESTORAGE_SKYLIGHT_7 | FINESTORAGE_SKYLIGHT_8 | FINESTORAGE_SKYLIGHT_9 | FINESTORAGE_SKYLIGHT_10 | FINESTORAGE_SKYLIGHT_5 | FINESTORAGE_SKYLIGHT_4 | FINESTORAGE_SKYLIGHT_3 | FINESTORAGE_SKYLIGHT_2 | FINESTORAGE_SKYLIGHT_14 | FINESTORAGE_SKYLIGHT_13 | FINESTORAGE_SKYLIGHT_12 | FINESTORAGE_SKYLIGHT_11 | SKYLIGHT_R8C1 | SKYLIGHT_R8C2 | SKYLIGHT_R8C4 | SKYLIGHT_R1C2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C4 | SKYLIGHT_R1C3 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R3C4 | SKYLIGHT_R3C2 | SKYLIGHT_R3C3 | SKYLIGHT_R3C1 | SKYLIGHT_R4C4 | SKYLIGHT_R4C3 | SKYLIGHT_R4C2 | SKYLIGHT_R4C1 | SKYLIGHT_R5C4 | SKYLIGHT_R5C1 | SKYLIGHT_R5C3 | SKYLIGHT_R5C2 | SKYLIGHT_R6C1 | SKYLIGHT_R6C2 | SKYLIGHT_R8C3 | SKYLIGHT_R6C4 | SKYLIGHT_R7C1 | SKYLIGHT_R7C2 | SKYLIGHT_R7C4 | SKYLIGHT_R6C3 | SKYLIGHT_R7C3 |WindowEnergyReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | FINESTORAGE_SKYLIGHT_1 | FINESTORAGE_SKYLIGHT_6 | FINESTORAGE_SKYLIGHT_7 | FINESTORAGE_SKYLIGHT_8 | FINESTORAGE_SKYLIGHT_9 | FINESTORAGE_SKYLIGHT_10 | FINESTORAGE_SKYLIGHT_5 | FINESTORAGE_SKYLIGHT_4 | FINESTORAGE_SKYLIGHT_3 | FINESTORAGE_SKYLIGHT_2 | FINESTORAGE_SKYLIGHT_14 | FINESTORAGE_SKYLIGHT_13 | FINESTORAGE_SKYLIGHT_12 | FINESTORAGE_SKYLIGHT_11 | SKYLIGHT_R8C1 | SKYLIGHT_R8C2 | SKYLIGHT_R8C4 | SKYLIGHT_R1C2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C4 | SKYLIGHT_R1C3 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R3C4 | SKYLIGHT_R3C2 | SKYLIGHT_R3C3 | SKYLIGHT_R3C1 | SKYLIGHT_R4C4 | SKYLIGHT_R4C3 | SKYLIGHT_R4C2 | SKYLIGHT_R4C1 | SKYLIGHT_R5C4 | SKYLIGHT_R5C1 | SKYLIGHT_R5C3 | SKYLIGHT_R5C2 | SKYLIGHT_R6C1 | SKYLIGHT_R6C2 | SKYLIGHT_R8C3 | SKYLIGHT_R6C4 | SKYLIGHT_R7C1 | SKYLIGHT_R7C2 | SKYLIGHT_R7C4 | SKYLIGHT_R6C3 | SKYLIGHT_R7C3 |WindowZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |WindowEnergyZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWHSYS1 WATER HEATER |DaylightingReportMonthly
| ZONE2 FINE STORAGE_DAYLCTRL | ZONE3 BULK STORAGE_DAYLCTRL | ZONE1 OFFICE_DAYLCTRL |CoilReportMonthly
| PSZ-OFFICE HEATING COIL | PSZ-FINE STORAGE HEATING COIL | ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |FanReportMonthly
| ZONE3UNITHEATER ZONE3HIRADIANT FAN | PSZ-OFFICE_ADDAQ SUPPLY FAN | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN |ZoneTemperatureOscillationReportMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentLoadsMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentEnergyUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |MechanicalVentilationLoadsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
GeneralValue | |
Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 10:43 |
RunPeriod | RUNPERIOD 1 |
Weather File | Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695 |
Latitude [deg] | 39.72 |
Longitude [deg] | -104.8 |
Elevation [m] | 1726.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 90.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | |
Gross Roof Area [m2] | 4598.25 |
Skylight Area [m2] | 68.38 |
Skylight-Roof Ratio [%] | 1.49 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
ZONE1 OFFICE | 236.88 | Yes | Yes | 1010.76 | 1.00 | 149.56 | 0.00 | 17.66 | 17.66 | 8.9961 | 18.58 | 8.0737 |
ZONE2 FINE STORAGE | 1393.41 | Yes | Yes | 2953.02 | 1.00 | 760.80 | 0.00 | 0.00 | 0.00 | 9.2031 | 46.45 | 0.0000 |
ZONE3 BULK STORAGE | 3204.84 | Yes | Yes | 35277.63 | 1.00 | 1586.63 | 0.00 | 0.00 | 0.00 | 5.6188 | 46.45 | 2.5587 |
Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 6.8172 | 43.27 | 2.0915 | |||
Conditioned Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 6.8172 | 43.27 | 2.0915 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
ZONE1 OFFICE | 236.88 | Yes | Yes | 1.00 | ZONE1 OFFICE | GENERAL | ZONE1 OFFICE | 8.9961 | 18.58 | 8.0737 | |
ZONE2 FINE STORAGE | 1393.41 | Yes | Yes | 1.00 | ZONE2 FINE STORAGE | GENERAL | ZONE2 FINE STORAGE | 9.2031 | 46.45 | 0.0000 | |
ZONE3 BULK STORAGE | 3204.84 | Yes | Yes | 1.00 | ZONE3 BULK STORAGE | GENERAL | ZONE3 BULK STORAGE | 5.6188 | 46.45 | 2.5587 | |
Total | 4835.13 | 6.8172 | 21.63 | 2.0915 | |||||||
Conditioned Total | 4835.13 | 6.8172 | 21.63 | 2.0915 | |||||||
Unconditioned Total | 0.00 | 0.0000 | 0.00 | 0.0000 | |||||||
Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
GENERAL | 4835.13 | 4835.13 | 0.00 | 0.00 | 6.8172 | 43.27 | 2.0915 |
Total | 4835.13 | 4835.13 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
End UsesElectricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 26-JUN-15:30 | 21-DEC-17:00 | - | - | - | - | - | - | - | - | - | - | 17-AUG-11:09 |
Heating | 0.00 | 218353.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 13077.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 9335.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 5020.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1604.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 39150.45 | 218353.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 218353.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 13077.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 9335.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 2715.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 1604.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 410.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 53.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 499.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 293.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 441.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 100.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 82.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1470.71 | 410.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 84.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 11.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 103.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 60.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 91.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 20.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 17.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 304.17 | 84.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 84.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 11.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 103.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 60.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 91.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 20.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 17.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 304.17 | 84.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
AirTerminal:SingleDuct:ConstantVolume:NoReheatDesign Size Maximum Air Flow Rate [m3/s] | |
ZONE1 OFFICE DIRECT AIR | 1.31 |
ZONE2 FINE STORAGE DIRECT AIR | 3.06 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
ZONE3 BULK STORAGE UNIT HEATER | 2.81 |
Design Size Maximum Flow Rate [m3/s] | |
ZONE3UNITHEATER ZONE3HIRADIANT FAN | 2.81 |
Design Size Nominal Capacity [W] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | 93494.64 |
PSZ-OFFICE HEATING COIL | 28247.79 |
PSZ-FINE STORAGE HEATING COIL | 87378.67 |
User-Specified Heating Design Capacity [W] | |
ZONE3 BULK STORAGE HIRADIANT | 93494.65 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-OFFICE | 1.31 | 1.31 | 1.31 | 1.31 | 1.31 | 1.31 | 1.00 | 1.00 | 1.31 |
PSZ-FINE STORAGE | 3.06 | 3.06 | 3.06 | 3.06 | 3.06 | 3.06 | 1.00 | 1.000000 | 3.06 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-OFFICE_OA_CONTROLLER | 1.31 | 0.102285 |
PSZ-FINE STORAGE_OA_CONTROLLER | 3.06 | 0.424711 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-OFFICE_ADDAQ SUPPLY FAN | 1.31 | 1447.58 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | 3.06 | 3272.34 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-OFFICE_UNITARY_PACKAGE_DX | 1.31 | 1.31 | 1.31 | 0.862932 | 21643.32 | 28247.79 | 40.00 | 1.00 |
PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | 3.06 | 3.06 | 3.06 | 2.02 | 57097.81 | 87378.67 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | User-Specified Speed 2 Rated Sensible Heat Ratio | User-Specified Speed 1 Rated Sensible Heat Ratio | |
PSZ-OFFICE COOLING COIL | 1.31 | 0.653736 | 0.871647 | 21643.32 | 10821.66 | 0.800660 | 0.800660 |
PSZ-FINE STORAGE COOLING COIL | 3.06 | 1.53 | 2.04 | 57097.81 | 28548.90 | 0.800960 | 0.800960 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
OFFICE FRONT WALL | OFFICE FRONT DOOR | OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | |
OFFICE LEFT WALL | OFFICE LEFT WALL DOOR | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | |
FINE STORAGE FRONT WALL | FINE STORAGE OVERHEAD DOOR1 | |
FINE STORAGE RIGHT WALL | FINE STORAGE OVERHEAD DOOR2 | FINE STORAGE OVERHEAD DOOR3 | FINE STORAGE RIGHT DOOR | |
FINE STORAGE LEFT WALL | FINE STORAGE OVERHEAD DOOR4 | FINE STORAGE LEFT DOOR | |
FINE STORAGE ROOF | FINESTORAGE_SKYLIGHT_1 | FINESTORAGE_SKYLIGHT_6 | FINESTORAGE_SKYLIGHT_7 | FINESTORAGE_SKYLIGHT_8 | FINESTORAGE_SKYLIGHT_9 | FINESTORAGE_SKYLIGHT_10 | FINESTORAGE_SKYLIGHT_5 | FINESTORAGE_SKYLIGHT_4 | FINESTORAGE_SKYLIGHT_3 | FINESTORAGE_SKYLIGHT_2 | FINESTORAGE_SKYLIGHT_14 | FINESTORAGE_SKYLIGHT_13 | FINESTORAGE_SKYLIGHT_12 | FINESTORAGE_SKYLIGHT_11 | |
BULK STORAGE RIGHT WALL | BULK STORAGE OVERHEAD DOOR8 | BULK STORAGE OVERHEAD DOOR9 | BULK STORAGE OVERHEAD DOOR10 | BULK STORAGE OVERHEAD DOOR11 | BULK STORAGE DOOR1 | BULK STORAGE DOOR2 | BULK STORAGE DOOR3 | |
BULK STORAGE REAR WALL | BULK STORAGE OVERHEAD DOOR12 | BULK STORAGE OVERHEAD DOOR13 | BULK STORAGE OVERHEAD DOOR14 | BULK STORAGE OVERHEAD DOOR15 | BULK STORAGE DOOR4 | |
BULK STORAGE LEFT WALL | BULK STORAGE OVERHEAD DOOR1 | BULK STORAGE OVERHEAD DOOR2 | BULK STORAGE OVERHEAD DOOR3 | BULK STORAGE OVERHEAD DOOR4 | BULK STORAGE OVERHEAD DOOR5 | BULK STORAGE OVERHEAD DOOR6 | BULK STORAGE OVERHEAD DOOR7 | BULK STORAGE DOOR5 | |
BULK STORAGE ROOF | SKYLIGHT_R8C1 | SKYLIGHT_R8C2 | SKYLIGHT_R8C4 | SKYLIGHT_R1C2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C4 | SKYLIGHT_R1C3 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R3C4 | SKYLIGHT_R3C2 | SKYLIGHT_R3C3 | SKYLIGHT_R3C1 | SKYLIGHT_R4C4 | SKYLIGHT_R4C3 | SKYLIGHT_R4C2 | SKYLIGHT_R4C1 | SKYLIGHT_R5C4 | SKYLIGHT_R5C1 | SKYLIGHT_R5C3 | SKYLIGHT_R5C2 | SKYLIGHT_R6C1 | SKYLIGHT_R6C2 | SKYLIGHT_R8C3 | SKYLIGHT_R6C4 | SKYLIGHT_R7C1 | SKYLIGHT_R7C2 | SKYLIGHT_R7C4 | SKYLIGHT_R6C3 | SKYLIGHT_R7C3 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
VersionVersion ID | |
1 | 22.1 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 7.10 | 3.00 | -1.00 | 0.80 | -0.20 | 4.80 | 6.10 | 13.70 | 22.20 | 22.70 | 21.70 | 18.50 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695 | 39.72 | -104.75 | -7.00 | 1726.00 | 82237 | 0.9774 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 9.95 | 23.70 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | Warehouse | 90.000 | Urban | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.220 | 370.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 3 | 102 | 78 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | ZONE1 OFFICE | 0.0 | 0.00 | 0.00 | 0.00 | 4.57 | -12.95 | 2.13 | 1 | 1 | 1 | 0.00 | 9.14 | -25.91 | 5.60E-016 | 0.00 | 4.27 | 4.27 | 1010.76 | TARP | TARP | 236.88 | 149.56 | 128.00 | 17.66 | 6 | 6 | 0 | Yes |
2 | ZONE2 FINE STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 14.29 | -22.82 | 4.51 | 1 | 1 | 1 | 0.00 | 30.48 | -45.72 | 1.87E-015 | 0.00 | 8.53 | 7.81 | 2953.02 | TARP | TARP | 1393.41 | 760.80 | 727.17 | 20.81 | 11 | 20 | 0 | Yes |
3 | ZONE3 BULK STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 65.53 | -22.86 | 4.27 | 1 | 1 | 1 | 30.48 | 100.58 | -45.72 | 6.16E-015 | 0.00 | 8.53 | 8.53 | 35277.63 | TARP | TARP | 3204.84 | 1586.63 | 1471.35 | 47.57 | 6 | 52 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | ZONE1 OFFICE | 236.88 | 12.7 | 18.581 | 5.382E-002 | 8.996 | 8.074 | 0.000 | 0.000 | 0.000 | 0.000 | 17.070 | No |
2 | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 46.447 | 2.153E-002 | 9.203 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 9.203 | No |
3 | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 46.447 | 2.153E-002 | 5.619 | 2.559 | 0.000 | 0.000 | 0.000 | 0.000 | 8.177 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
1 | OFFICE PEOPLE | BLDG_OCC_SCH | ZONE1 OFFICE | 236.88 | 12.7 | 12.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | OFFICE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 13 |
2 | ZONE2 FINE STORAGEPEOPLE | BLDG_OCC_SCH | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 30.0 | 2.153E-002 | 46.447 | 0.300 | 0.700 | AutoCalculate | ZONE2 FINE STORAGE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 30 |
3 | ZONE3 BULK STORAGEPEOPLE | BLDG_OCC_SCH | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 69.0 | 2.153E-002 | 46.447 | 0.300 | 0.700 | AutoCalculate | ZONE3 BULK STORAGE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 69 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | OFFICE LIGHTS | LTG_SCH_OFFICE | ZONE1 OFFICE | 236.88 | 12.7 | 2131.000 | 8.996 | 167.154 | 0.000 | 0.370 | 0.180 | 0.450 | 1.000 | LightsWired | 0.000 | 2131.000 |
2 | FINE STORAGE AREA LIGHTS | LTG_SCH_FINE_STORAGE | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 12823.730 | 9.203 | 427.458 | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 12823.730 |
3 | BULK STORAGE AREA LIGHTS | LTG_SCH_BULK_STORAGE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 18007.220 | 5.619 | 260.974 | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 18007.220 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | OFFICE PLUG LOAD | OFFICE_PLUG_SCH | ZONE1 OFFICE | 236.88 | 12.7 | 1912.500 | 8.074 | 150.015 | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 1912.500 |
2 | BULK STORAGE PLUG LOAD | BULK STORAGE PLUG SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 8200.120 | 2.559 | 118.842 | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 8200.120 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | NONRES_ROOF | 16 | 2 | 2 | 0.167 | 0.2043 | 0.900 | 0.900 | 0.770 | 0.700 | Smooth |
2 | SEMIHEATED_ROOF | 18 | 2 | 2 | 0.167 | 0.2043 | 0.900 | 0.900 | 0.770 | 0.700 | Smooth |
3 | NONRES_EXT_WALL_GRD | 19 | 3 | 4 | 0.167 | 0.4095 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | SEMIHEATED_EXT_WALL_GRD | 25 | 3 | 4 | 0.167 | 0.4095 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | SWINGING DOOR_CON | 41 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
6 | SWINGING DOOR_SEMI | 42 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | OVERHEAD DOOR_SEMI | 44 | 1 | 1 | 0.167 | 1.198 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
8 | OVERHEAD DOOR_CON | 45 | 1 | 1 | 0.167 | 1.198 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
9 | BULK STORAGE PRODUCTS | 46 | 1 | 18 | 0.500 | 0.5914 | 0.900 | 0.900 | 0.700 | 0.700 | Rough |
10 | INTERIOR WALL | 47 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
11 | INSULATEDCEILING | 48 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
12 | OFFICEFLOOR_FFACTOR | 49 | 2 | 7 | 0.167 | 0.1413 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | FINESTORAGEFLOOR_FFACTOR | 50 | 2 | 7 | 0.167 | 0.5841E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | BULKSTORAGEFLOOR_FFACTOR | 51 | 2 | 7 | 0.167 | 0.5469E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | iz-INTERIOR WALL | 52 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
16 | iz-SEMIHEATED_EXT_WALL_GRD | 53 | 3 | 4 | 0.167 | 0.4095 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
17 | iz-INSULATEDCEILING | 54 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
2 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.894 |
3 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
4 | SEMIHEATED_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.894 |
5 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
6 | NONRES_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 2.343 |
7 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | SEMIHEATED_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 2.343 |
10 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
11 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
12 | OPAQUE DOOR PANEL_SEMI | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
13 | OVERHEAD DOOR_SEMI PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8346 |
14 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8346 |
15 | BULK STORAGE PRODUCTS MATERIAL | 2.4384 | 1.442 | 200.231 | 836.800 | 1.691 |
16 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
17 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
18 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
19 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
20 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
21 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
22 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
23 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.998 |
24 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
25 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 17.04 |
26 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
27 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 18.21 |
28 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
29 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
30 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
31 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
32 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
33 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
34 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
35 | SEMIHEATED_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 2.343 |
36 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
37 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
38 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 2 | 0.93400083E-12 | 0.71827744E-17 | 0.33026303E-17 | 0.0000000 |
2 | 1 | -5.2160660 | 0.53236032E-04 | -0.78408200E-04 | 0.17906231E-12 |
3 | 0 | 5.4203831 | 0.20426382 | 0.20439547 | |
4 | 2 | 0.93400083E-12 | 0.71827744E-17 | 0.33026303E-17 | 0.0000000 |
5 | 1 | -5.2160660 | 0.53236032E-04 | -0.78408200E-04 | 0.17906231E-12 |
6 | 0 | 5.4203831 | 0.20426382 | 0.20439547 | |
7 | 4 | 0.79647225E-12 | 0.96147816E-16 | -0.20666597E-14 | 0.11382549E-15 |
8 | 3 | -0.38972706E-03 | 0.28930881E-06 | -0.56581374E-04 | 0.15282143E-12 |
9 | 2 | 1.7513786 | 0.62914578E-02 | 1.1494565 | -0.74717338E-04 |
10 | 1 | -7.1131205 | 0.16244765 | -17.155584 | 0.33567575 |
11 | 0 | 5.6342095 | 0.10333854 | 16.278262 | |
12 | 4 | 0.79647225E-12 | 0.96147816E-16 | -0.20666597E-14 | 0.11382549E-15 |
13 | 3 | -0.38972706E-03 | 0.28930881E-06 | -0.56581374E-04 | 0.15282143E-12 |
14 | 2 | 1.7513786 | 0.62914578E-02 | 1.1494565 | -0.74717338E-04 |
15 | 1 | -7.1131205 | 0.16244765 | -17.155584 | 0.33567575 |
16 | 0 | 5.6342095 | 0.10333854 | 16.278262 | |
17 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
18 | 0 | 2.1009573 | 2.1009573 | 2.1009573 | |
19 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
20 | 0 | 2.1009573 | 2.1009573 | 2.1009573 | |
21 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
22 | 0 | 1.1981135 | 1.1981135 | 1.1981135 | |
23 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
24 | 0 | 1.1981135 | 1.1981135 | 1.1981135 | |
25 | 18 | 0.12003549E-12 | -0.36149852E-21 | 0.11999160E-12 | -0.69171859E-14 |
26 | 17 | -0.26702818E-10 | 0.22043783E-17 | -0.26702965E-10 | 0.15647703E-11 |
27 | 16 | 0.26199194E-08 | 0.46087291E-16 | 0.26199192E-08 | -0.15597178E-09 |
28 | 15 | -0.14918350E-06 | -0.27301975E-15 | -0.14918350E-06 | 0.90448703E-08 |
29 | 14 | 0.54929883E-05 | 0.10218664E-13 | 0.54929883E-05 | -0.34010628E-06 |
30 | 13 | -0.13812653E-03 | 0.13886261E-11 | -0.13812653E-03 | 0.87613853E-05 |
31 | 12 | 0.24466257E-02 | 0.76740851E-10 | 0.24466257E-02 | -0.15954016E-03 |
32 | 11 | -0.31099262E-01 | 0.20215154E-08 | -0.31099262E-01 | 0.20926433E-02 |
33 | 10 | 0.28694928 | 0.26940884E-07 | 0.28694928 | -0.20002833E-01 |
34 | 9 | -1.9353699 | 0.18750649E-06 | -1.9353699 | 0.14030665 |
35 | 8 | 9.5767226 | 0.68900696E-06 | 9.5767226 | -0.72468789 |
36 | 7 | -34.784653 | 0.13258951E-05 | -34.784653 | 2.7565275 |
37 | 6 | 92.438040 | 0.12976568E-05 | 92.438040 | -7.6923258 |
38 | 5 | -178.18614 | 0.60985027E-06 | -178.18614 | 15.604270 |
39 | 4 | 245.02895 | 0.12430126E-06 | 245.02895 | -22.615757 |
40 | 3 | -233.27712 | 0.91617964E-08 | -233.27712 | 22.714127 |
41 | 2 | 145.61910 | 0.16319500E-09 | 145.61910 | -14.964058 |
42 | 1 | -53.478849 | 0.26256209E-11 | -53.478849 | 5.7996512 |
43 | 0 | 8.7411694 | -0.39181092E-12 | 8.7411694 | |
44 | 5 | -0.68112304E-12 | 0.61645773E-13 | -0.20199983E-12 | 0.95058421E-15 |
45 | 4 | 0.71499529E-06 | 0.73238302E-07 | 0.28552134E-06 | -0.33479849E-12 |
46 | 3 | -0.58529659E-02 | 0.62218017E-03 | -0.21917430E-02 | 0.29169470E-06 |
47 | 2 | 1.2914758 | 0.88958368E-01 | 0.40042664 | -0.15953103E-02 |
48 | 1 | -8.6129398 | 0.38073474 | -3.1694576 | 0.22491773 |
49 | 0 | 7.9317533 | 0.13060792 | 3.3724149 | |
50 | 3 | -0.49407978E-15 | 0.44230608E-16 | -0.53860842E-16 | 0.0000000 |
51 | 2 | 0.54884850E-03 | 0.14309697E-03 | 0.26444340E-03 | -0.39739853E-15 |
52 | 1 | -3.9407614 | 2.0053241 | -3.6132068 | 0.31450573E-03 |
53 | 0 | 13.994357 | 8.0573072 | 13.672611 | |
54 | 7 | -0.30042996E-08 | -0.19492532E-14 | 0.18571942E-14 | -0.50265421E-16 |
55 | 6 | 0.40686135E-05 | 0.27025218E-08 | 0.31944093E-02 | -0.26797382E-04 |
56 | 5 | -0.28598357E-03 | 0.15982348E-05 | -0.22398257 | 0.19584275E-02 |
57 | 4 | 0.65354345E-02 | 0.72696005E-04 | 4.8338424 | -0.45306284E-01 |
58 | 3 | -0.57256805E-01 | 0.57768437E-03 | -38.045688 | 0.39892203 |
59 | 2 | 0.20312160 | 0.96045137E-03 | 116.53119 | -1.4185711 |
60 | 1 | -0.29305691 | 0.29236276E-03 | -143.93511 | 2.0494970 |
61 | 0 | 0.14285049 | 0.70905046E-05 | 60.838472 | |
62 | 7 | -0.73310212E-08 | 0.16277859E-15 | -0.15558641E-14 | 0.17403554E-16 |
63 | 6 | 0.21213446E-05 | 0.11327280E-08 | 0.32008460E-02 | -0.26851379E-04 |
64 | 5 | -0.12816801E-03 | 0.66411688E-06 | -0.22434819 | 0.19616548E-02 |
65 | 4 | 0.27852559E-02 | 0.30072908E-04 | 4.8399282 | -0.45364789E-01 |
66 | 3 | -0.23934818E-01 | 0.23808113E-03 | -38.080046 | 0.39930184 |
67 | 2 | 0.84241938E-01 | 0.39442809E-03 | 116.59803 | -1.4194653 |
68 | 1 | -0.12110434 | 0.11951395E-03 | -143.97445 | 2.0501436 |
69 | 0 | 0.58923671E-01 | 0.28881054E-05 | 60.838472 | |
70 | 7 | -0.78336681E-08 | 0.23380828E-15 | -0.37470831E-14 | 0.17001158E-16 |
71 | 6 | 0.20573783E-05 | 0.10635783E-08 | 0.32011355E-02 | -0.26853807E-04 |
72 | 5 | -0.12166809E-03 | 0.62270931E-06 | -0.22436462 | 0.19617998E-02 |
73 | 4 | 0.26229018E-02 | 0.28177105E-04 | 4.8402013 | -0.45367414E-01 |
74 | 3 | -0.22467346E-01 | 0.22293819E-03 | -38.081586 | 0.39931887 |
75 | 2 | 0.78971204E-01 | 0.36912476E-03 | 116.60102 | -1.4195054 |
76 | 1 | -0.11345740 | 0.11176675E-03 | -143.97621 | 2.0501725 |
77 | 0 | 0.55185584E-01 | 0.26976542E-05 | 60.838472 | |
78 | 5 | -0.20199983E-12 | 0.61645773E-13 | -0.68112304E-12 | 0.95058421E-15 |
79 | 4 | 0.28552134E-06 | 0.73238302E-07 | 0.71499529E-06 | -0.33479849E-12 |
80 | 3 | -0.21917430E-02 | 0.62218017E-03 | -0.58529659E-02 | 0.29169470E-06 |
81 | 2 | 0.40042664 | 0.88958368E-01 | 1.2914758 | -0.15953103E-02 |
82 | 1 | -3.1694576 | 0.38073474 | -8.6129398 | 0.22491773 |
83 | 0 | 3.3724149 | 0.13060792 | 7.9317533 | |
84 | 4 | -0.20666597E-14 | 0.96147816E-16 | 0.79647225E-12 | 0.11382549E-15 |
85 | 3 | -0.56581374E-04 | 0.28930881E-06 | -0.38972706E-03 | 0.15282143E-12 |
86 | 2 | 1.1494565 | 0.62914578E-02 | 1.7513786 | -0.74717338E-04 |
87 | 1 | -17.155584 | 0.16244765 | -7.1131205 | 0.33567575 |
88 | 0 | 16.278262 | 0.10333854 | 5.6342095 | |
89 | 3 | -0.53860842E-16 | 0.44230608E-16 | -0.49407978E-15 | 0.0000000 |
90 | 2 | 0.26444340E-03 | 0.14309697E-03 | 0.54884850E-03 | -0.39739853E-15 |
91 | 1 | -3.6132068 | 2.0053241 | -3.9407614 | 0.31450573E-03 |
92 | 0 | 13.672611 | 8.0573072 | 13.994357 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | Conductance (Before Adjusted) {W/m2-K} | Convection Coefficient Adjustment Ratio | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.3818_SHGC_SOUTH_0.4 | 34 | 1 | VerySmooth | 2.169 | 2.169 | 1.000 | 0.401 | ||
2 | NONRESWINDOW_U_0.3818_SHGC_NORTH_0.4 | 35 | 1 | VerySmooth | 2.169 | 2.169 | 1.000 | 0.401 | ||
3 | NONRESWINDOW_U_0.3818_SHGC_EAST_0.4 | 36 | 1 | VerySmooth | 2.169 | 2.169 | 1.000 | 0.401 | ||
4 | NONRESWINDOW_U_0.3818_SHGC_WEST_0.4 | 37 | 1 | VerySmooth | 2.169 | 2.169 | 1.000 | 0.401 | ||
5 | SKYLIGHT_U_0.75_SHGC_0.6 | 38 | 1 | VerySmooth | 4.262 | 4.262 | 1.000 | 0.605 | ||
6 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | 39 | 1 | VerySmooth | 4.262 | 4.262 | 1.000 | 0.605 | ||
7 | SKYLIGHT DOUBLE CLEAR | 43 | 3 | VerySmooth | 3.715 | 3.715 | 1.000 | 0.720 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER SOUTH | SpectralAverage | 3.44070E-002 | 0.31435 | 0.47919 | 0.47919 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.11919 | 1.00000 | No | |
2 | NONRES WINDOW GLAZING LAYER NORTH | SpectralAverage | 3.44070E-002 | 0.31435 | 0.47919 | 0.47919 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.11919 | 1.00000 | No | |
3 | NONRES WINDOW GLAZING LAYER EAST | SpectralAverage | 3.44070E-002 | 0.31435 | 0.47919 | 0.47919 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.11919 | 1.00000 | No | |
4 | NONRES WINDOW GLAZING LAYER WEST | SpectralAverage | 3.44070E-002 | 0.31435 | 0.47919 | 0.47919 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.11919 | 1.00000 | No | |
5 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.47441 | 0.15233 | 0.15233 | 0.60000 | 0.13030 | 0.15164 | 0.00000 | 0.84000 | 0.84000 | 2.99465E-002 | 1.00000 | No | |
6 | SEMIHEATED SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.47441 | 0.15233 | 0.15233 | 0.60000 | 0.13030 | 0.15164 | 0.00000 | 0.84000 | 0.84000 | 2.99465E-002 | 1.00000 | No | |
7 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No | |
8 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No |
Material Name | GasType | Thickness {m} | |
1 | AIR 3MM | Air | 3.200E-003 |
Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
Enclosure Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Enclosures | |
1 | ZONE1 OFFICE | 4 | 0 |
2 | ZONE2 FINE STORAGE | 14 | 0 |
3 | ZONE3 BULK STORAGE | 32 | 0 |
Enclosure Name | Number of Adjacent Enclosures with Windows | Adjacent Enclosure Names - 1st 100 (max) | |
1 | ZONE1 OFFICE | 0 | |
2 | ZONE2 FINE STORAGE | 0 | |
3 | ZONE3 BULK STORAGE | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 7.5708E-002 | 6154.7 | 1.055 | 0.5308 |
Construction Name | Frame and Divider Name | NFRC Product Type | Assembly U-Factor {W/m2-K} | Assembly SHGC | Assembly Visible Transmittance | |
1 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | CurtainWall | 4.099 | 0.605 | 0.602 |
2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | CurtainWall | 4.099 | 0.605 | 0.602 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | OFFICE INFILTRATION | OFFICE INFIL SCHEDULE | ZONE1 OFFICE | 236.88 | 12.7 | 8.518E-002 | 3.596E-004 | 5.551E-004 | 0.303 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | OFFICE DOOR INFILTRATION | INFIL_DOOR_OPENING_SCH | ZONE1 OFFICE | 236.88 | 12.7 | 0.289 | 1.219E-003 | 1.882E-003 | 1.029 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | FINE STORAGE INFILTRATION | FINE SORAGE INFIL SCHEDULE | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 0.433 | 3.110E-004 | 1.981E-004 | 0.528 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | BULK STORAGE INFILTRATION | BULK STORAGE INFIL_BASE SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 2.710 | 8.455E-004 | 5.523E-004 | 0.277 | 0.000 | 0.000 | 0.224 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
1 | BULK STORAGE VENTILATION-1 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 37.760 | 1.178E-002 | 0.547 | 3.853 | Exhaust | 31.136 | 0.5 | 1.000 | 0.000 | 0.000 | 0.000 | 29.44 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
2 | BULK STORAGE VENTILATION-2 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 0.944 | 2.945E-004 | 1.368E-002 | 9.632E-002 | Natural | 0.000 | 1.0 | 0.000 | 0.000 | 0.224 | 0.000 | -73.33 | 29.44 | -100.00 | -100.00 | 100.00 | 40.00 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | ZONE1 OFFICE | Mixing/Well-Stirred |
2 | ZONE2 FINE STORAGE | Mixing/Well-Stirred |
3 | ZONE3 BULK STORAGE | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Sky Type | MonthAndDay | Daylighting Control Name | Enclosure Name | Window Name | Reference Point | Daylight Factor | |
1 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.4259E-004 |
2 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.0582E-003 |
3 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.2506E-004 |
4 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.1283E-003 |
5 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.2465E-004 |
6 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.2203E-003 |
7 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.5727E-004 |
8 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT2 | 7.2026E-004 |
9 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.6110E-004 |
10 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT2 | 6.0997E-004 |
11 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.1790E-004 |
12 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT2 | 6.8947E-004 |
13 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.5079E-004 |
14 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT2 | 4.8663E-004 |
15 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.7631E-004 |
16 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.3735E-004 |
17 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.6488E-004 |
18 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT2 | 3.0533E-004 |
19 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT1 | 4.7267E-004 |
20 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT2 | 3.4540E-004 |
21 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT1 | 7.4051E-004 |
22 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.1134E-004 |
23 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.2192E-003 |
24 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.2548E-004 |
25 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0553E-003 |
26 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.7040E-004 |
27 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.5585E-004 |
28 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.8737E-004 |
29 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.6694E-003 |
30 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.2651E-004 |
31 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.0518E-003 |
32 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.7651E-005 |
33 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.1309E-003 |
34 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.1648E-004 |
35 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.1780E-003 |
36 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.2372E-004 |
37 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.4210E-003 |
38 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.8685E-005 |
39 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.3050E-004 |
40 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.9351E-005 |
41 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT1 | 7.0182E-004 |
42 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.4206E-005 |
43 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT1 | 7.8822E-004 |
44 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.7457E-005 |
45 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.9706E-004 |
46 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.8405E-005 |
47 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.9123E-004 |
48 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.6423E-005 |
49 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.4673E-003 |
50 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.6932E-005 |
51 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.7544E-003 |
52 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.0086E-004 |
53 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.4250E-004 |
54 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.9133E-005 |
55 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.8041E-004 |
56 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.6567E-005 |
57 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.5716E-003 |
58 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.2530E-004 |
59 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.8655E-003 |
60 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.3483E-004 |
61 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.7492E-003 |
62 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.0105E-004 |
63 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.7108E-003 |
64 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.9807E-005 |
65 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.2504E-003 |
66 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.0479E-004 |
67 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.0815E-003 |
68 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.3104E-004 |
69 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.4480E-003 |
70 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.3587E-004 |
71 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.3923E-003 |
72 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.9389E-005 |
73 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.0558E-004 |
74 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT2 | 4.6538E-004 |
75 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT1 | 7.4693E-004 |
76 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.4997E-004 |
77 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.1374E-003 |
78 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.5779E-004 |
79 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.4880E-003 |
80 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.3403E-004 |
81 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.3183E-004 |
82 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.2327E-003 |
83 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.7100E-004 |
84 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.4802E-003 |
85 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.0759E-004 |
86 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT2 | 7.3396E-004 |
87 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.2548E-004 |
88 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.9448E-004 |
89 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.5776E-004 |
90 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.3816E-003 |
91 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.3609E-004 |
92 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.7186E-003 |
93 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.3294E-004 |
94 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.2696E-003 |
95 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.7670E-004 |
96 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.2140E-003 |
97 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0498E-004 |
98 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.5090E-003 |
99 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.6414E-005 |
100 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.4237E-003 |
101 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.5385E-005 |
102 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT2 | 3.6942E-003 |
103 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0952E-004 |
104 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT2 | 4.8074E-003 |
105 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0114E-004 |
106 | Clear Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.1333E-003 |
107 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.3666E-005 |
108 | Clear Turbid Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.0567E-003 |
109 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.3835E-005 |
110 | Intermediate Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.7674E-003 |
111 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0607E-004 |
112 | Overcast Sky | 12/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.9054E-003 |
113 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.3898E-005 |
114 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.1077E-005 |
115 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.6900E-005 |
116 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.6741E-005 |
117 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.6672E-005 |
118 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.1463E-005 |
119 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.6204E-005 |
120 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.6978E-005 |
121 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.6493E-005 |
122 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.4854E-005 |
123 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.3433E-005 |
124 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.4906E-005 |
125 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.9208E-005 |
126 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.2594E-005 |
127 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.1603E-005 |
128 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.7987E-005 |
129 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.4040E-005 |
130 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.3294E-005 |
131 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.6957E-005 |
132 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.1455E-005 |
133 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.6411E-005 |
134 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.3693E-005 |
135 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.6179E-005 |
136 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.6280E-005 |
137 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.6220E-004 |
138 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.8800E-004 |
139 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 4.2685E-004 |
140 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.0750E-004 |
141 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.1038E-004 |
142 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.4526E-004 |
143 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.2840E-005 |
144 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.8788E-005 |
145 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2336E-004 |
146 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.2831E-004 |
147 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3084E-004 |
148 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.4192E-004 |
149 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0631E-004 |
150 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.4926E-004 |
151 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.6674E-005 |
152 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.8401E-005 |
153 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1867E-004 |
154 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.8806E-005 |
155 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2491E-004 |
156 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.8142E-005 |
157 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0473E-004 |
158 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.0413E-005 |
159 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.6649E-005 |
160 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.6333E-005 |
161 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.4136E-004 |
162 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.7335E-005 |
163 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.9958E-004 |
164 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.8229E-005 |
165 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.0649E-004 |
166 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.4599E-005 |
167 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.2818E-005 |
168 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.6078E-005 |
169 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7786E-004 |
170 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.3106E-003 |
171 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.8355E-004 |
172 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.5968E-003 |
173 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7904E-004 |
174 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.2603E-004 |
175 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0481E-004 |
176 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.5886E-004 |
177 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.7906E-004 |
178 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.2139E-004 |
179 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.1282E-004 |
180 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.4731E-004 |
181 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.5102E-004 |
182 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.0121E-004 |
183 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2532E-004 |
184 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.5335E-004 |
185 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.3333E-004 |
186 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.5569E-005 |
187 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.5322E-004 |
188 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.4181E-005 |
189 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.3892E-004 |
190 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0109E-004 |
191 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2519E-004 |
192 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.1885E-005 |
193 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7095E-004 |
194 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.1983E-005 |
195 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7501E-004 |
196 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.0609E-005 |
197 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7563E-004 |
198 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.4899E-005 |
199 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0473E-004 |
200 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9439E-005 |
201 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2974E-003 |
202 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1170E-004 |
203 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4294E-003 |
204 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0582E-004 |
205 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4009E-003 |
206 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.3242E-004 |
207 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.8908E-004 |
208 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.8211E-005 |
209 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3544E-003 |
210 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.8580E-004 |
211 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5023E-003 |
212 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9353E-004 |
213 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4288E-003 |
214 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.1036E-004 |
215 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.8995E-004 |
216 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.7855E-004 |
217 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2541E-004 |
218 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.4275E-005 |
219 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.1837E-004 |
220 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.2063E-005 |
221 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.8451E-004 |
222 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.8642E-005 |
223 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.8972E-004 |
224 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.3063E-005 |
225 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.3313E-004 |
226 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.2015E-003 |
227 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2747E-004 |
228 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.5409E-003 |
229 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9066E-004 |
230 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.0164E-003 |
231 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.9000E-004 |
232 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0465E-003 |
233 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4121E-004 |
234 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.4758E-005 |
235 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.1832E-004 |
236 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.1885E-005 |
237 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.4688E-004 |
238 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.9514E-005 |
239 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9915E-004 |
240 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.5702E-005 |
241 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4484E-003 |
242 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1598E-004 |
243 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3945E-003 |
244 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0557E-004 |
245 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.1737E-003 |
246 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.4588E-004 |
247 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4291E-003 |
248 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.2389E-004 |
249 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4823E-003 |
250 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.3487E-004 |
251 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4342E-003 |
252 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9204E-004 |
253 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2103E-003 |
254 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.3370E-004 |
255 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4336E-003 |
256 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.8360E-004 |
257 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4662E-004 |
258 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.3534E-003 |
259 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2427E-004 |
260 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.3400E-003 |
261 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.5433E-004 |
262 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.3466E-003 |
263 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9975E-004 |
264 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.9790E-003 |
265 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.0005E-004 |
266 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.3150E-005 |
267 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7256E-004 |
268 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.0045E-005 |
269 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.6882E-004 |
270 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.6663E-005 |
271 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9750E-004 |
272 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.5670E-005 |
273 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.0188E-004 |
274 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.2154E-003 |
275 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7461E-004 |
276 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0313E-003 |
277 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.7392E-004 |
278 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.7169E-003 |
279 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9810E-004 |
280 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.9042E-003 |
281 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.6353E-004 |
282 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0467E-004 |
283 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.3185E-004 |
284 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.2901E-005 |
285 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2594E-003 |
286 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.2466E-004 |
287 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.3923E-003 |
288 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.2355E-004 |
289 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.6956E-004 |
290 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.9446E-004 |
291 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.3842E-004 |
292 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.3566E-004 |
293 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2756E-003 |
294 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.7775E-004 |
295 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.3968E-003 |
296 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.7651E-004 |
297 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3870E-004 |
298 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.5505E-004 |
299 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1781E-004 |
300 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.6459E-004 |
301 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5255E-004 |
302 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9159E-004 |
303 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.8771E-004 |
304 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0145E-003 |
305 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.7498E-004 |
306 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.2575E-004 |
307 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.0275E-004 |
308 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.8597E-004 |
309 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 4.1544E-004 |
310 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.5049E-004 |
311 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.6872E-004 |
312 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.7148E-004 |
313 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.6606E-005 |
314 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.3871E-005 |
315 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.3483E-005 |
316 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9412E-005 |
317 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.9022E-005 |
318 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.0321E-005 |
319 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.1582E-005 |
320 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.5852E-005 |
321 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3864E-004 |
322 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.0051E-005 |
323 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1750E-004 |
324 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.7156E-005 |
325 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5037E-004 |
326 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.1719E-005 |
327 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.8744E-004 |
328 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.2992E-005 |
329 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.0970E-005 |
330 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.8191E-004 |
331 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.8272E-005 |
332 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.4623E-004 |
333 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.4134E-005 |
334 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.5210E-004 |
335 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0363E-004 |
336 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.5247E-004 |
337 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.6375E-004 |
338 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.2270E-004 |
339 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3283E-004 |
340 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0207E-004 |
341 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3981E-004 |
342 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0817E-004 |
343 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2024E-004 |
344 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.5078E-004 |
345 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.1181E-005 |
346 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.6485E-005 |
347 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.8316E-005 |
348 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.4080E-005 |
349 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.3377E-005 |
350 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.7027E-005 |
351 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0355E-004 |
352 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9366E-005 |
353 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.7515E-004 |
354 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.5109E-005 |
355 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.0249E-004 |
356 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.5123E-005 |
357 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 4.1178E-004 |
358 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.9184E-005 |
359 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.6788E-004 |
360 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.7598E-005 |
361 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.6402E-004 |
362 | Clear Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.6737E-005 |
363 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3292E-004 |
364 | Clear Turbid Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.9702E-005 |
365 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3905E-004 |
366 | Intermediate Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.3526E-005 |
367 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2011E-004 |
368 | Overcast Sky | 12/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.1450E-005 |
369 | Clear Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 6.0018E-003 |
370 | Clear Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 6.9371E-004 |
371 | Clear Turbid Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 5.4670E-003 |
372 | Clear Turbid Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 6.3697E-004 |
373 | Intermediate Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 5.1066E-003 |
374 | Intermediate Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 6.0186E-004 |
375 | Overcast Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 2.8599E-003 |
376 | Overcast Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 5.0221E-004 |
377 | Clear Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 7.1442E-004 |
378 | Clear Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 6.3441E-003 |
379 | Clear Turbid Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 6.7375E-004 |
380 | Clear Turbid Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 5.4089E-003 |
381 | Intermediate Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 6.1463E-004 |
382 | Intermediate Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 5.4736E-003 |
383 | Overcast Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 4.9649E-004 |
384 | Overcast Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 3.8464E-003 |
385 | Clear Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 5.2870E-003 |
386 | Clear Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 3.7439E-004 |
387 | Clear Turbid Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 3.9372E-003 |
388 | Clear Turbid Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 2.9426E-004 |
389 | Intermediate Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 2.5323E-003 |
390 | Intermediate Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 2.2198E-004 |
391 | Overcast Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 3.5869E-003 |
392 | Overcast Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 3.0592E-004 |
393 | Clear Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 5.2584E-003 |
394 | Clear Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 3.7429E-004 |
395 | Clear Turbid Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 3.9233E-003 |
396 | Clear Turbid Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 2.9421E-004 |
397 | Intermediate Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 2.5616E-003 |
398 | Intermediate Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 2.2204E-004 |
399 | Overcast Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 3.5869E-003 |
400 | Overcast Sky | 12/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 3.0592E-004 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | ZONE1 OFFICE | Cooling | 10750.15905 | 12900.19086 | 1.08956 | 1.30747 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 32.42000 | 5.47299E-003 | 236.87965 | 12.74874 | 0.10228 | 0.00000 |
2 | ZONE1 OFFICE | Heating | 9519.00821 | 11422.80985 | 0.32923 | 0.39507 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -17.90000 | 9.55238E-004 | 236.87965 | 12.74874 | 0.10228 | 0.00000 |
3 | ZONE2 FINE STORAGE | Cooling | 32257.63908 | 38709.16690 | 2.54844 | 3.05812 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 33.90000 | 5.47527E-003 | 1393.40969 | 30.00000 | 0.42471 | 0.00000 |
4 | ZONE2 FINE STORAGE | Heating | 29366.67366 | 35240.00840 | 0.85540 | 1.02648 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 06:00:00 | -17.90000 | 9.55238E-004 | 1393.40969 | 30.00000 | 0.42471 | 0.00000 |
5 | ZONE3 BULK STORAGE | Cooling | 0.00000 | 0.00000 | 0.00000 | 0.97684 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 33.75200 | 5.47504E-003 | 3204.84228 | 69.00000 | 0.97684 | 0.00000 |
6 | ZONE3 BULK STORAGE | Heating | 77912.20953 | 93494.65144 | 2.34513 | 2.81415 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | -17.90000 | 9.55238E-004 | 3204.84228 | 69.00000 | 0.97684 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-OFFICE | Cooling | Sensible | 16158.67 | 1.30747 | 1.30747 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
2 | PSZ-OFFICE | Heating | Sensible | 11266.15 | 0.39507 | 0.39507 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 |
3 | PSZ-FINE STORAGE | Cooling | Sensible | 47156.22 | 3.05812 | 3.05812 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
4 | PSZ-FINE STORAGE | Heating | Sensible | 38600.59 | 1.02648 | 1.02648 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 06:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ZONE1 OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.30747 |
2 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ZONE2 FINE STORAGE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 3.05812 |
3 | ZoneHVAC:UnitHeater | ZONE3 BULK STORAGE UNIT HEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 2.81415 |
4 | Fan:ConstantVolume | ZONE3UNITHEATER ZONE3HIRADIANT FAN | Design Size Maximum Flow Rate [m3/s] | 2.81415 |
5 | Coil:Heating:Fuel | ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | Design Size Nominal Capacity [W] | 93494.64235 |
6 | ZoneHVAC:HighTemperatureRadiant | ZONE3 BULK STORAGE HIRADIANT | User-Specified Heating Design Capacity [W] | 93494.65144 |
7 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.30747 |
8 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.30747 |
9 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.30747 |
10 | AirLoopHVAC | PSZ-OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 1.30747 |
11 | AirLoopHVAC | PSZ-OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.30747 |
12 | AirLoopHVAC | PSZ-OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 1.30747 |
13 | AirLoopHVAC | PSZ-OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
14 | AirLoopHVAC | PSZ-OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 3.05812 |
16 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 3.05812 |
17 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 3.05812 |
18 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Heating Design Air Flow Rate [m3/s] | 3.05812 |
19 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Cooling Design Air Flow Rate [m3/s] | 3.05812 |
20 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Main Design Air Flow Rate [m3/s] | 3.05812 |
21 | AirLoopHVAC | PSZ-FINE STORAGE | User Heating Air Flow Ratio [] | 1.00000 |
22 | AirLoopHVAC | PSZ-FINE STORAGE | Calculated Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-OFFICE | Design Supply Air Flow Rate [m3/s] | 1.30747 |
24 | AirLoopHVAC | PSZ-FINE STORAGE | Design Supply Air Flow Rate [m3/s] | 3.05812 |
25 | Controller:OutdoorAir | PSZ-OFFICE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.30747 |
26 | Controller:OutdoorAir | PSZ-OFFICE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.10228 |
27 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.30747 |
28 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 1447.57983 |
29 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.30747 |
30 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.30747 |
31 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.30747 |
32 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.86293 |
33 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.30747 |
34 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.65374 |
35 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.87165 |
36 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 21643.32000 |
37 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 10821.66000 |
38 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.80066 |
39 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.80066 |
40 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 21643.32000 |
41 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 28247.79275 |
42 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
43 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
44 | Coil:Heating:Fuel | PSZ-OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 28247.79275 |
45 | Controller:OutdoorAir | PSZ-FINE STORAGE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 3.05812 |
46 | Controller:OutdoorAir | PSZ-FINE STORAGE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.42471 |
47 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 3.05812 |
48 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 3272.33688 |
49 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 3.05812 |
50 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 3.05812 |
51 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 3.05812 |
52 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 2.01836 |
53 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 3.05812 |
54 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.52906 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 2.03875 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 57097.81000 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 28548.90500 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.80096 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.80096 |
60 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 57097.81000 |
61 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 87378.66841 |
62 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
63 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
64 | Coil:Heating:Fuel | PSZ-FINE STORAGE HEATING COIL | Design Size Nominal Capacity [W] | 87378.66841 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | 20628.8 | 11.40 | 11.14 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | 54723.8 | 11.51 | 11.25 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1Environment:Special Days |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | ZONE1 OFFICE | RunPeriod: RUNPERIOD 1 | 0.1320699343 | 0.1399362635 | Pass | Pass | 1.4766831316 | 6.7305011079 | Pass | Pass |
2 | ZONE2 FINE STORAGE | RunPeriod: RUNPERIOD 1 | 0.3950025711 | 0.3962963779 | Pass | Pass | 1.9459202252 | 15.3397588542 | Pass | Pass |
3 | ZONE3 BULK STORAGE | RunPeriod: RUNPERIOD 1 | 3.1984273044E-003 | 8.7708553668E-003 | Pass | Pass | 6.4409255881E-002 | 0.1220032458 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Heat Emission by ComponentsEnvelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
Heat Emissions [GJ] | 9885.76 | 519.56 | 0.00 | 63.12 | 177.59 | 10646.06 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | -17.90 | 0.00 | -17.90 | Wetbulb [C] | 2.50 | 180.00 |
DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 14.80 | 15.00 | Wetbulb [C] | 3.60 | 30.00 |
Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
Jan | 11.00 | 10 | |||
Feb | 15.00 | 16 | |||
Mar | 88.00 | 32 | |||
Apr | 159.00 | 54 | |||
May | 30.00 | 24 | |||
Jun | 11.00 | 4 | |||
Jul | 167.00 | 26 | |||
Aug | 33.00 | 24 | |||
Sep | 8.00 | 8 | |||
Oct | 13.00 | 10 | |||
Nov | 12.00 | 22 | |||
Dec | 11.00 | 18 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 110.54 | 97.44 | 270.00 | 90.00 | W |
OFFICE LEFT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 39.02 | 30.56 | 0.00 | 90.00 | N |
OFFICE FLOOR | OFFICEFLOOR_FFACTOR | 1.00 | 0.138 | 0.141 | 236.88 | 236.88 | 90.00 | 180.00 | |
FINE STORAGE FRONT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 169.07 | 161.64 | 270.00 | 90.00 | W |
FINE STORAGE RIGHT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 260.10 | 243.29 | 180.00 | 90.00 | S |
FINE STORAGE LEFT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 182.07 | 172.69 | 0.00 | 90.00 | N |
FINE STORAGE OFFICE FRONT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 110.54 | 110.54 | 270.00 | 90.00 | W |
FINE STORAGE OFFICE LEFT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 39.02 | 39.02 | 0.00 | 90.00 | N |
FINE STORAGE FLOOR | FINESTORAGEFLOOR_FFACTOR | 1.00 | 0.058 | 0.058 | 1156.53 | 1156.53 | 90.00 | 180.00 | |
FINE STORAGE ROOF | NONRES_ROOF | 0.23 | 0.199 | 0.204 | 1393.41 | 1372.60 | 90.00 | 0.00 | |
BULK STORAGE RIGHT WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 598.24 | 568.60 | 180.00 | 90.00 | S |
BULK STORAGE REAR WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 390.15 | 358.48 | 90.00 | 90.00 | E |
BULK STORAGE LEFT WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 598.24 | 544.27 | 0.00 | 90.00 | N |
BULK STORAGE FLOOR | BULKSTORAGEFLOOR_FFACTOR | 1.00 | 0.054 | 0.055 | 3204.84 | 3204.84 | 90.00 | 180.00 | |
BULK STORAGE ROOF | SEMIHEATED_ROOF | 0.23 | 0.199 | 0.204 | 3204.84 | 3157.28 | 270.00 | 0.00 |
Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE RIGHT WALL | INTERIOR WALL | 0.30 | 0.653 | 0.775 | 39.02 | 39.02 | 180.00 | 90.00 | S |
OFFICE REAR WALL | INTERIOR WALL | 0.30 | 0.653 | 0.775 | 110.54 | 110.54 | 90.00 | 90.00 | E |
OFFICE ROOF | INSULATEDCEILING | 0.30 | 2.711 | 10.063 | 236.88 | 236.88 | 90.00 | 0.00 | |
iz-OFFICE RIGHT WALL | iz-INTERIOR WALL | 0.30 | 0.653 | 0.775 | 39.02 | 39.02 | 0.00 | 90.00 | N |
iz-OFFICE REAR WALL | iz-INTERIOR WALL | 0.30 | 0.653 | 0.775 | 110.54 | 110.54 | 270.00 | 90.00 | W |
iz-BULK STORAGE FRONT WALL | iz-SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.373 | 0.410 | 390.15 | 390.15 | 270.00 | 90.00 | W |
iz-OFFICE ROOF | iz-INSULATEDCEILING | 0.30 | 2.711 | 10.063 | 236.88 | 236.88 | 270.00 | 180.00 | |
BULK STORAGE FRONT WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.373 | 0.410 | 390.15 | 390.15 | 90.00 | 90.00 | E |
BULK STORAGE PRODUCTS SURFACE | BULK STORAGE PRODUCTS | 0.30 | 0.591 | 6028.45 | 0.00 | 90.00 | N |
Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL WINDOW 1 | NONRESWINDOW_U_0.3818_SHGC_WEST_0.4 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 2.169 | 0.401 | 0.402 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | |||||||
OFFICE FRONT WALL WINDOW2 | NONRESWINDOW_U_0.3818_SHGC_WEST_0.4 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 2.169 | 0.401 | 0.402 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | |||||||
OFFICE LEFT WALL WINDOW1 | NONRESWINDOW_U_0.3818_SHGC_NORTH_0.4 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 2.169 | 0.401 | 0.402 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | |||||||
OFFICE LEFT WALL WINDOW2 | NONRESWINDOW_U_0.3818_SHGC_NORTH_0.4 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 2.169 | 0.401 | 0.402 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | |||||||
FINESTORAGE_SKYLIGHT_1 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_6 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_7 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_8 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_9 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_10 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_5 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_4 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_3 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_2 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_14 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_13 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_12 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_11 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R8C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R8C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R8C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R1C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R1C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R1C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R1C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R2C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R2C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R2C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R2C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R3C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R3C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R3C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R3C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R4C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R4C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R4C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R4C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R5C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R5C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R5C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R5C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R6C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R6C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R8C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R6C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R7C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R7C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R7C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R6C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R7C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
Total or Average | 86.04 | 3.832 | 0.563 | 0.561 | |||||||||||||||||
North Total or Average | 6.51 | 2.169 | 0.401 | 0.402 | |||||||||||||||||
Non-North Total or Average | 79.53 | 3.968 | 0.576 | 0.574 |
Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
None |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
OFFICE FRONT DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | OFFICE FRONT WALL |
OFFICE LEFT WALL DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | OFFICE LEFT WALL |
FINE STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_CON | 1.016 | 1.198 | 7.43 | FINE STORAGE FRONT WALL |
FINE STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_CON | 1.016 | 1.198 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_CON | 1.016 | 1.198 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE RIGHT DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_CON | 1.016 | 1.198 | 7.43 | FINE STORAGE LEFT WALL |
FINE STORAGE LEFT DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | FINE STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR8 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR9 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR10 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR11 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR1 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR2 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR3 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR12 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR13 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR14 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR15 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE DOOR4 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR5 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR6 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR7 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE DOOR5 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE LEFT WALL |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
OFFICE FRONT WALL WINDOW 1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE FRONT WALL WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE LEFT WALL WINDOW1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
OFFICE LEFT WALL WINDOW2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FINESTORAGE_SKYLIGHT_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_6 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_7 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_8 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_9 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_10 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_5 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_14 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_13 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R8C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R8C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R8C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R3C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R3C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R3C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R3C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R4C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R4C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R4C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R4C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R5C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R5C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R5C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R5C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R6C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R6C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R8C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R6C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R7C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R7C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R7C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R6C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R7C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Interior LightingZone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
OFFICE LIGHTS | ZONE1 OFFICE | ZONE1 OFFICE | GENERAL | 8.9961 | 236.88 | 2131.00 | LightsWired | LTG_SCH_OFFICE | 51.55 | 168.00 | 45.98 | 0.0000 | Y | 18.39 |
FINE STORAGE AREA LIGHTS | ZONE2 FINE STORAGE | ZONE2 FINE STORAGE | GENERAL | 9.2031 | 1393.41 | 12823.73 | LightsWired | LTG_SCH_FINE_STORAGE | 34.09 | 168.00 | 26.07 | 0.0000 | Y | 62.76 |
BULK STORAGE AREA LIGHTS | ZONE3 BULK STORAGE | ZONE3 BULK STORAGE | GENERAL | 5.6188 | 3204.84 | 18007.22 | LightsWired | LTG_SCH_BULK_STORAGE | 34.09 | 168.00 | 22.68 | 0.0000 | Y | 76.66 |
Interior Lighting Total | 6.8172 | 4835.13 | 32961.95 | 157.81 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
ZONE2 FINE STORAGE_DAYLREFPT1 | ZONE2 FINE STORAGE | ZONE2 FINE STORAGE_DAYLCTRL | SplitFlux | Stepped | 0.25 | 12823.73 | 3205.93 |
ZONE2 FINE STORAGE_DAYLREFPT2 | ZONE2 FINE STORAGE | ZONE2 FINE STORAGE_DAYLCTRL | SplitFlux | Stepped | 0.25 | 12823.73 | 3205.93 |
ZONE3 BULK STORAGE_DAYLREFPT1 | ZONE3 BULK STORAGE | ZONE3 BULK STORAGE_DAYLCTRL | SplitFlux | Stepped | 0.25 | 18007.22 | 4501.81 |
ZONE3 BULK STORAGE_DAYLREFPT2 | ZONE3 BULK STORAGE | ZONE3 BULK STORAGE_DAYLCTRL | SplitFlux | Stepped | 0.25 | 18007.22 | 4501.81 |
ZONE1 OFFICE_DAYLREFPT1 | ZONE1 OFFICE | ZONE1 OFFICE_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 2131.00 | 309.00 |
ZONE1 OFFICE_DAYLREFPT2 | ZONE1 OFFICE | ZONE1 OFFICE_DAYLCTRL | SplitFlux | Continuous/Off | 0.05 | 2131.00 | 106.55 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 94.73 | AstronomicalClock | - | 42.26 | 42.26 | 0.75 | |
EXTERIOR_LIGHTS_B | 6863.48 | AstronomicalClock | - | 83.67 | 71.25 | 91.79 | |
Exterior Lighting Total | 6958.21 | 92.55 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Central PlantType | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 21643.32 | 17328.94 | 4314.38 | 0.80 | 3.80 | |||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 57097.81 | 45733.06 | 11364.75 | 0.80 | 3.73 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-OFFICE COOLING COIL | 20628.8 | 11.40 | 11.14 | ||||
PSZ-FINE STORAGE COOLING COIL | 54723.8 | 11.51 | 11.25 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | Coil:Heating:Fuel | 93494.64 | 0.80 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | 28247.79 | 0.80 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | 87378.67 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
ZONE3UNITHEATER ZONE3HIRADIANT FAN | Fan:ConstantVolume | 0.54 | 49.80 | 2.81 | 261.46 | 92.91 | 1.00 | 3.39 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 |
PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.56 | 622.50 | 1.31 | 1447.58 | 1107.16 | 1.00 | 1.34 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.58 | 622.50 | 3.06 | 3272.34 | 1070.05 | 1.00 | 1.26 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SWHSYS1 WATER HEATER | WaterHeater:Mixed | 0.08 | 6154.75 | 1.00 | 1.06 | 0.53 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 10750.16 | 12900.19 | 54.46 | 1.090 | 1.307 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 23.90 | 23.90 | 0.00820 | 32.42 | 0.00547 | 0.102 | 0.00 |
ZONE2 FINE STORAGE | 32257.64 | 38709.17 | 27.78 | 2.548 | 3.058 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 26.70 | 26.70 | 0.00810 | 33.90 | 0.00548 | 0.425 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 | 0.000 | 0.977 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 0.00 | 33.76 | 0.00556 | 33.75 | 0.00548 | 0.977 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 9519.01 | 11422.81 | 48.22 | 0.329 | 0.395 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 21.10 | 21.10 | 0.00781 | -17.90 | 0.00096 | 0.102 | 0.00 |
ZONE2 FINE STORAGE | 29366.67 | 35240.01 | 25.29 | 0.855 | 1.026 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 06:00:00 | 15.56 | 15.56 | 0.00661 | -17.90 | 0.00096 | 0.425 | 0.00 |
ZONE3 BULK STORAGE | 77912.21 | 93494.65 | 29.17 | 2.345 | 2.814 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 10.00 | 10.00 | 0.00535 | -17.90 | 0.00096 | 0.977 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-OFFICE | 1.31 | 1.31 | 0.40 | 0.40 | 1.3075 | 1.3075 | 1.3075 | 1.0000 | 1.0000 |
PSZ-FINE STORAGE | 3.06 | 3.06 | 1.03 | 1.03 | 3.0581 | 3.0581 | 3.0581 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER or ZONEHVAC:HIGHTEMPERATURERADIANT | ZONE3 BULK STORAGE UNIT HEATER or ZONE3 BULK STORAGE HIRADIANT | 93494.642 | 93494.642 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 93494.64 | 93494.64 | 2.814155 | 10.00 | 5.81 | 0.00535154 | 43.33 | 19.68 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 10.00 | 0.00535154 | 57.1394 | 93494.65 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-OFFICE | 21643.320 | 17328.941 | 1.307470 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:10:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 10821.66 | 10821.66 | 0.871647 | 25.71 | 14.40 | 0.00798703 | 12.00 | 9.41 | 0.00798703 | 32.81 | 0.00547359 | 14.72 | 11.7346 | 23.90 | 0.00820062 | 36.0677 | 10737.74 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-OFFICE | 28247.793 | 28247.793 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 28247.79 | 28247.79 | 1.307473 | 18.00 | 11.06 | 0.00727406 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 7.8231 | 21.10 | 0.00781034 | 40.7481 | 9519.01 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-FINE STORAGE | 57097.810 | 45733.062 | 3.058120 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 28548.90 | 28548.90 | 2.038747 | 28.77 | 15.20 | 0.00773282 | 12.00 | 9.16 | 0.00773282 | 33.90 | 0.00547527 | 15.07 | 20.8320 | 26.70 | 0.00809691 | 30.1523 | 32257.64 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-FINE STORAGE | 87378.668 | 87378.668 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 06:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 06:00:00 | 87378.67 | 87378.67 | 3.058124 | 10.91 | 6.74 | 0.00582832 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 13.8880 | 15.56 | 0.00661424 | 48.9596 | 29366.67 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER or ZONEHVAC:HIGHTEMPERATURERADIANT | ZONE3 BULK STORAGE UNIT HEATER or ZONE3 BULK STORAGE HIRADIANT | ZONE3 BULK STORAGE | N/A | N/A | N/A | Yes | No | unknown | No | 93494.642 | 93494.642 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | ZONE3UNITHEATER ZONE3HIRADIANT FAN | Fan:ConstantVolume | 2.814155 | 2.75066075 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | Sensible | 93494.64 | 93494.64 | 1.0000 | 2.75066075 | 2.814155 | 10.00 | 5.81 | 0.00535154 | 23528.9 | 43.33 | 19.68 | 0.00800000 | 64191.6 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 93494.64 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 10.00 | 0.00535154 | 10.00 | 0.00535154 | 57.1394 | 93494.65 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 21643.320 | 17328.941 | 1.307470 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.6875 | 1004.8586 | 0.9774 | PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 1.307473 | 1.27797300 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:10:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:10:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | Sensible | 10821.66 | 10821.66 | 1.0000 | 0.85198024 | 0.871647 | 25.71 | 14.40 | 0.00798703 | 46189.5 | 12.00 | 9.41 | 0.00798703 | 32211.3 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10821.66 | 32.81 | 0.00547359 | 14.72 | 0.10228463 | 11.7346 | 23.90 | 0.00820062 | 23.90 | 0.00820062 | 36.0677 | 10737.74 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 28247.793 | 28247.793 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 1.307473 | 1.27797300 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | Sensible | 28247.79 | 28247.79 | 1.0000 | 1.27797300 | 1.307473 | 18.00 | 11.06 | 0.00727406 | 36525.9 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 28247.79 | -17.90 | 0.00095524 | -17.90 | 0.10228463 | 7.8231 | 21.05 | 0.00781034 | 21.10 | 0.00781034 | 40.7481 | 9519.01 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 57097.810 | 45733.062 | 3.058120 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.2149 | 1004.8586 | 0.9774 | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 3.058124 | 2.98912509 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | Sensible | 28548.90 | 28548.90 | 1.0000 | 1.99274767 | 2.038747 | 28.77 | 15.20 | 0.00773282 | 48666.0 | 12.00 | 9.16 | 0.00773282 | 31569.9 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 28548.90 | 33.90 | 0.00547527 | 15.07 | 0.42471127 | 20.8320 | 26.70 | 0.00809691 | 26.70 | 0.00809691 | 30.1523 | 32257.64 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 87378.668 | 87378.668 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 3.058124 | 2.98912509 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 06:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 06:00:00 | Sensible | 87378.67 | 87378.67 | 1.0000 | 2.98912509 | 3.058124 | 10.91 | 6.74 | 0.00582832 | 25656.4 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 87378.67 | -17.90 | 0.00095524 | -17.90 | 0.42471127 | 13.8880 | 15.56 | 0.00661424 | 15.56 | 0.00661424 | 48.9596 | 29366.67 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-OFFICE_OA_CONTROLLER | DifferentialDryBulb | 0.10 | 1.31 | - | |||
PSZ-FINE STORAGE_OA_CONTROLLER | DifferentialDryBulb | 0.42 | 3.06 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
ZONE1 OFFICE | 2655.67 | 2500.50 | 1759.83 |
ZONE2 FINE STORAGE | 3136.33 | 2906.50 | 2487.50 |
ZONE3 BULK STORAGE | 3300.17 | 3390.33 | 3107.17 |
Facility | 3435.83 | 3421.50 | 3128.00 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
ZONE1 OFFICE | 43.33 | 0.00 | 19.17 | 0.00 |
ZONE2 FINE STORAGE | 347.33 | 30.33 | 21.00 | 0.00 |
ZONE3 BULK STORAGE | 12.83 | 0.00 | 2.33 | 0.00 |
Facility | 385.67 | 30.33 | 33.67 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 9.50 | 12.75 | 1010.76 | 0.569 | 0.434 | 0.000 | 0.000 |
ZONE2 FINE STORAGE | 22.36 | 30.00 | 2953.02 | 0.548 | 0.237 | 0.000 | 0.000 |
ZONE3 BULK STORAGE | 51.43 | 69.00 | 35277.63 | 0.000 | 0.141 | 0.000 | 0.346 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 9.50 | 12.75 | 1010.76 | 0.000 | 0.000 | 0.000 | 0.000 |
ZONE2 FINE STORAGE | 22.36 | 30.00 | 2953.02 | 0.000 | 0.000 | 0.000 | 0.000 |
ZONE3 BULK STORAGE | 51.43 | 69.00 | 35277.63 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Mechanical Ventilation Parameters by ZoneAirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
ZONE1 OFFICE | PSZ-OFFICE | 9.50 | 12.75 | 1010.76 | 236.88 | 0.1023 | 0.102 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 22.36 | 30.00 | 2953.02 | 1393.41 | 0.4247 | 0.425 |
ZONE3 BULK STORAGE | 51.43 | 69.00 | 35277.63 | 3204.84 | 0.977 | ||
Total Facility | 83.29 | 111.75 | 39241.41 | 4835.13 | 0.5270 | 1.504 |
Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
ZONE1 OFFICE | 2070459.38 | 0.00 | 2070459.38 | 2328759.83 | 4399219.21 | 3225648.14 | 5704.03 | 2412.98 | 642.99 | 0.00 |
ZONE2 FINE STORAGE | 5914463.13 | 0.00 | 5914463.13 | 6789202.86 | 12703665.99 | 13393694.68 | 5707.52 | 2644.50 | 407.98 | 15.41 |
ZONE3 BULK STORAGE | 0.00 | 65134574.36 | 65134574.36 | 38312560.14 | 0.10E+09 | 30805497.77 | 7887.54 | 35.92 | 836.54 | 5116.83 |
Total Facility | 7984922.51 | 65134574.36 | 73119496.87 | 47430522.83 | 0.12E+09 | 47424840.58 | 8242.47 | 2837.25 | 1624.94 | 5116.83 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
ZONE1 OFFICE | 0.1582 | 0.0000 | 0.1582 | 0.1208 | 0.2790 | 0.1023 | 580.03 | 2412.98 | 642.99 |
ZONE2 FINE STORAGE | 0.4460 | 0.0000 | 0.4460 | 0.1939 | 0.6399 | 0.4247 | 598.93 | 2644.50 | 392.58 |
ZONE3 BULK STORAGE | 0.0000 | 3.3088 | 3.3088 | 1.3923 | 4.7012 | 0.9768 | 3098.64 | 17.50 | 519.86 |
Total Facility | 0.6042 | 3.3088 | 3.9130 | 1.7070 | 5.6200 | 1.5038 | 3118.47 | 2818.83 | 1294.46 |
Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
PSZ-OFFICE | 1978033.29 | 0.00 | 1978033.29 | 3225648.14 | 8118.65 | 0.67 | 640.69 | 0.00 |
PSZ-FINE STORAGE | 5650577.97 | 0.00 | 5650577.97 | 13393694.68 | 8353.18 | 0.83 | 405.98 | 15.41 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
PSZ-OFFICE | 0.1511 | 0.0000 | 0.1511 | 0.1023 | 2994.65 | 0.67 | 640.69 |
PSZ-FINE STORAGE | 0.4261 | 0.0000 | 0.4261 | 0.4247 | 3244.59 | 0.83 | 390.58 |
No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
PSZ-OFFICE | 0.00 | 2838.24 | 224.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PSZ-FINE STORAGE | 0.00 | 2930.72 | 130.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
PSZ-OFFICE | 0.0000 | 0.1698 | 0.3012 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
PSZ-FINE STORAGE | 0.0000 | 0.4939 | 0.8425 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Surfaces by ClassTotal | Outdoors | |
Wall | 16 | 10 |
Floor | 4 | 3 |
Roof | 3 | 2 |
Internal Mass | 1 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 50 | 50 |
Door | 28 | 28 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 2 |
Conditioned Zones | 3 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 429 |
Defaulted Fields | 391 |
Fields with Defaults | 1171 |
Autosized Fields | 43 |
Autosizable Fields | 97 |
Autocalculated Fields | 128 |
Autocalculatable Fields | 206 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 464.39 | 2146.58 | 19-FEB-13:40 | 39150.45 | 26-JUN-15:30 |
Electricity:Building | 300.23 | 1663.58 | 19-FEB-13:40 | 25798.69 | 04-JAN-16:00 |
Electricity:Zone:ZONE1 OFFICE | 50.34 | 815.73 | 16-JAN-15:30 | 3198.43 | 02-JAN-16:50 |
Electricity:SpaceType:GENERAL | 297.10 | 1663.58 | 19-FEB-13:40 | 25798.69 | 04-JAN-16:00 |
InteriorLights:Electricity | 157.81 | 1089.83 | 19-FEB-13:40 | 15686.07 | 04-JAN-16:00 |
InteriorLights:Electricity:Zone:ZONE1 OFFICE | 18.39 | 241.98 | 16-JAN-15:30 | 1285.93 | 02-JAN-16:50 |
InteriorLights:Electricity:SpaceType:GENERAL | 157.81 | 1089.83 | 19-FEB-13:40 | 15686.07 | 04-JAN-16:00 |
LightsWired:InteriorLights:Electricity | 157.81 | 1089.83 | 19-FEB-13:40 | 15686.07 | 04-JAN-16:00 |
LightsWired:InteriorLights:Electricity:Zone:ZONE1 OFFICE | 18.39 | 241.98 | 16-JAN-15:30 | 1285.93 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 157.81 | 1089.83 | 19-FEB-13:40 | 15686.07 | 04-JAN-16:00 |
Electricity:Zone:ZONE2 FINE STORAGE | 62.76 | 352.65 | 19-FEB-13:10 | 5995.09 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:ZONE2 FINE STORAGE | 62.76 | 352.65 | 19-FEB-13:10 | 5995.09 | 02-JAN-09:10 |
LightsWired:InteriorLights:Electricity:Zone:ZONE2 FINE STORAGE | 62.76 | 352.65 | 19-FEB-13:10 | 5995.09 | 02-JAN-09:10 |
Electricity:Zone:ZONE3 BULK STORAGE | 187.14 | 495.20 | 08-JAN-10:50 | 16618.50 | 02-JAN-16:00 |
InteriorLights:Electricity:Zone:ZONE3 BULK STORAGE | 76.66 | 495.20 | 08-JAN-10:50 | 8418.38 | 02-JAN-16:00 |
LightsWired:InteriorLights:Electricity:Zone:ZONE3 BULK STORAGE | 76.66 | 495.20 | 08-JAN-10:50 | 8418.38 | 02-JAN-16:00 |
InteriorEquipment:Electricity | 139.29 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE1 OFFICE | 31.95 | 573.75 | 01-JAN-00:10 | 1912.50 | 02-JAN-08:10 |
InteriorEquipment:Electricity:SpaceType:GENERAL | 139.29 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity | 139.29 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ZONE1 OFFICE | 31.95 | 573.75 | 01-JAN-00:10 | 1912.50 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 139.29 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE3 BULK STORAGE | 107.34 | 0.00 | 01-JAN-00:10 | 8200.12 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ZONE3 BULK STORAGE | 107.34 | 0.00 | 01-JAN-00:10 | 8200.12 | 02-JAN-08:10 |
Fans:Electricity | 31.72 | 0.00 | 01-JAN-10:10 | 5121.09 | 26-JUN-15:10 |
Fans:Electricity:Zone:ZONE3 BULK STORAGE | 3.14 | 0.00 | 01-JAN-00:10 | 2305.29 | 26-JUN-09:50 |
Ventilation (simple):Fans:Electricity | 3.14 | 0.00 | 01-JAN-00:10 | 2305.29 | 26-JUN-09:50 |
Ventilation (simple):Fans:Electricity:Zone:ZONE3 BULK STORAGE | 3.14 | 0.00 | 01-JAN-00:10 | 2305.29 | 26-JUN-09:50 |
ElectricityPurchased:Facility | 464.39 | 2146.58 | 19-FEB-13:40 | 39150.45 | 26-JUN-15:30 |
ElectricityPurchased:Plant | 464.39 | 2146.58 | 19-FEB-13:40 | 39150.45 | 26-JUN-15:30 |
Cogeneration:ElectricityPurchased | 464.39 | 2146.58 | 19-FEB-13:40 | 39150.45 | 26-JUN-15:30 |
General:Cogeneration:ElectricityPurchased | 464.39 | 2146.58 | 19-FEB-13:40 | 39150.45 | 26-JUN-15:30 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 464.39 | 2146.58 | 19-FEB-13:40 | 39150.45 | 26-JUN-15:30 |
ElectricityNet:Plant | 464.39 | 2146.58 | 19-FEB-13:40 | 39150.45 | 26-JUN-15:30 |
Cogeneration:ElectricityNet | 464.39 | 2146.58 | 19-FEB-13:40 | 39150.45 | 26-JUN-15:30 |
General:Cogeneration:ElectricityNet | 464.39 | 2146.58 | 19-FEB-13:40 | 39150.45 | 26-JUN-15:30 |
Electricity:HVAC | 45.56 | 0.00 | 01-JAN-10:10 | 16316.31 | 26-JUN-15:10 |
General:Fans:Electricity | 28.58 | 0.00 | 01-JAN-10:10 | 4080.13 | 21-DEC-18:00 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 16.98 | 0.00 | 01-JAN-00:10 | 13500.51 | 26-JUN-15:10 |
General:Cooling:Electricity | 16.98 | 0.00 | 01-JAN-00:10 | 13500.51 | 26-JUN-15:10 |
ExteriorLights:Electricity | 92.55 | 0.00 | 01-JAN-07:30 | 6958.21 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 92.55 | 0.00 | 01-JAN-07:30 | 6958.21 | 01-JAN-06:10 |
Electricity:Plant | 26.05 | 483.00 | 14-JAN-06:10 | 2604.94 | 13-FEB-13:00 |
WaterSystems:Electricity | 26.05 | 483.00 | 14-JAN-06:10 | 2604.94 | 13-FEB-13:00 |
Water Heater:WaterSystems:Electricity | 26.05 | 483.00 | 14-JAN-06:10 | 2604.94 | 13-FEB-13:00 |
Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
NaturalGas:Facility | 378.87 | 0.00 | 01-JAN-10:10 | 218353.45 | 21-DEC-18:00 |
NaturalGas:HVAC | 378.87 | 0.00 | 01-JAN-10:10 | 218353.45 | 21-DEC-18:00 |
Heating:NaturalGas | 378.87 | 0.00 | 01-JAN-10:10 | 218353.45 | 21-DEC-18:00 |
General:Heating:NaturalGas | 378.87 | 0.00 | 01-JAN-10:10 | 218353.45 | 21-DEC-18:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 17-AUG-11:10 |
Water:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 17-AUG-11:10 |
WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 17-AUG-11:10 |
Water Heater:WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 17-AUG-11:10 |
MainsWater:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 17-AUG-11:10 |
MainsWater:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 17-AUG-11:10 |
WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 17-AUG-11:10 |
Water Heater:WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 17-AUG-11:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
EnergyTransfer:Facility | 698.09 | 0.00 | 01-JAN-10:10 | 324070.98 | 21-DEC-18:00 |
EnergyTransfer:Building | 348.79 | 0.00 | 01-JAN-10:10 | 154413.29 | 21-DEC-18:00 |
EnergyTransfer:Zone:ZONE1 OFFICE | 51.13 | 0.00 | 01-JAN-00:10 | 24739.45 | 20-DEC-07:10 |
Heating:EnergyTransfer | 273.89 | 0.00 | 01-JAN-10:10 | 154413.29 | 21-DEC-18:00 |
Heating:EnergyTransfer:Zone:ZONE1 OFFICE | 25.50 | 0.00 | 01-JAN-00:10 | 24739.45 | 20-DEC-07:10 |
General:Heating:EnergyTransfer | 273.89 | 0.00 | 01-JAN-10:10 | 154413.29 | 21-DEC-18:00 |
General:Heating:EnergyTransfer:Zone:ZONE1 OFFICE | 25.50 | 0.00 | 01-JAN-00:10 | 24739.45 | 20-DEC-07:10 |
Cooling:EnergyTransfer | 74.90 | 0.00 | 01-JAN-00:10 | 33440.55 | 26-JUN-15:10 |
Cooling:EnergyTransfer:Zone:ZONE1 OFFICE | 25.62 | 0.00 | 01-JAN-00:10 | 12007.10 | 26-JUN-17:00 |
General:Cooling:EnergyTransfer | 74.90 | 0.00 | 01-JAN-00:10 | 33440.55 | 26-JUN-15:10 |
General:Cooling:EnergyTransfer:Zone:ZONE1 OFFICE | 25.62 | 0.00 | 01-JAN-00:10 | 12007.10 | 26-JUN-17:00 |
EnergyTransfer:Zone:ZONE2 FINE STORAGE | 127.13 | 0.00 | 01-JAN-00:10 | 46119.24 | 21-DEC-18:50 |
Heating:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 77.86 | 0.00 | 01-JAN-00:10 | 46119.24 | 21-DEC-18:50 |
General:Heating:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 77.86 | 0.00 | 01-JAN-00:10 | 46119.24 | 21-DEC-18:50 |
Cooling:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 49.27 | 0.00 | 01-JAN-00:10 | 23329.57 | 26-JUN-15:10 |
General:Cooling:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 49.27 | 0.00 | 01-JAN-00:10 | 23329.57 | 26-JUN-15:10 |
EnergyTransfer:Zone:ZONE3 BULK STORAGE | 170.53 | 0.00 | 01-JAN-09:40 | 94443.06 | 21-DEC-18:00 |
Heating:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 170.53 | 0.00 | 01-JAN-09:40 | 94443.06 | 21-DEC-18:00 |
General:Heating:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 170.53 | 0.00 | 01-JAN-09:40 | 94443.06 | 21-DEC-18:00 |
Cooling:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cooling:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 349.30 | 0.00 | 01-JAN-10:10 | 169657.69 | 21-DEC-18:00 |
HeatingCoils:EnergyTransfer | 283.78 | 0.00 | 01-JAN-10:10 | 169657.69 | 21-DEC-18:00 |
CoolingCoils:EnergyTransfer | 65.52 | 0.00 | 01-JAN-00:10 | 43083.24 | 26-JUN-15:10 |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
ZONE1 OFFICE | 0.000 | 0.000 | 25.502 | -25.623 | 0.000 | 0.000 | 9.968 | 18.391 | 31.946 | 14.144 | 0.000 | 1.440 | 0.000 | 0.000 | -8.883 | 0.000 | -26.502 | -40.384 |
ZONE2 FINE STORAGE | 0.000 | 0.000 | 77.858 | -49.273 | 0.000 | 0.000 | 24.909 | 62.758 | 0.000 | 59.795 | 0.000 | 1.665 | 0.001 | 0.000 | -20.872 | 0.000 | -70.178 | -86.660 |
ZONE3 BULK STORAGE | 170.532 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 61.080 | 76.658 | 107.344 | 599.995 | 0.000 | 30.637 | 0.001 | 0.000 | -174.605 | 0.000 | -420.500 | -451.143 |
Total Facility | 170.532 | 0.000 | 103.359 | -74.896 | 0.000 | 0.000 | 95.957 | 157.807 | 139.290 | 673.934 | 0.000 | 33.742 | 0.002 | 0.000 | -204.360 | 0.000 | -517.179 | -578.187 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 10-JUN-07:02 | 0.00 | 0.00 | 0.00 | -26010.67 | 0.00 | 0.00 | 801.53 | 1123.59 | 1912.50 | 302.22 | 0.00 | 0.00 | 22322.07 | 0.00 | -0.00 | 0.00 | -451.24 | 0.00 |
ZONE2 FINE STORAGE | 20-AUG-14:33 | 0.00 | 0.00 | 0.00 | -49284.48 | 0.00 | 0.00 | 0.00 | 470.20 | 0.00 | 8584.19 | 0.00 | 338.34 | 39891.75 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 20-AUG-14:33 | 0.00 | 0.00 | 0.00 | -49284.48 | 0.00 | 0.00 | 0.00 | 1207.38 | 573.75 | 128426.18 | 0.00 | 338.34 | 0.00 | 0.00 | 0.00 | 0.00 | -2965.99 | -78295.18 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 22-DEC-06:31 | 0.00 | 0.00 | 29839.01 | 0.00 | 0.00 | 0.00 | 151.23 | 384.11 | 573.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1139.05 | 0.00 | -2959.24 | -26849.82 |
ZONE2 FINE STORAGE | 22-DEC-06:01 | 0.00 | 0.00 | 90837.87 | 0.00 | 0.00 | 0.00 | 379.98 | 705.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2540.28 | 0.00 | -7070.27 | -82312.61 |
ZONE3 BULK STORAGE | 21-DEC-18:00 | 94441.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2677.16 | 5942.38 | 2050.03 | 0.00 | 0.00 | 0.00 | 19663.31 | 0.00 | -27479.61 | 0.00 | -97294.35 | 0.00 |
Total Facility | 20-DEC-06:42 | 88555.03 | 0.00 | 114498.99 | 0.00 | 0.00 | 0.00 | 1446.37 | 2079.82 | 2623.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -27731.18 | 0.00 | -80692.75 | -100780.05 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 1.3075 | 0.0000 | 12.7487 | 1.0000 | Calculated from schedules | 0.1023 | 1.3075 | 0.0782 | 1.0000 | Not calculated | 0.1023 | 0.0782 | ||
PSZ-FINE STORAGE | 3.0581 | 0.0000 | 30.0000 | 1.0000 | Calculated from schedules | 0.4247 | 3.0581 | 0.1389 | 1.0000 | Not calculated | 0.4247 | 0.1389 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 1.3075 | 0.0000 | 12.7487 | 1.0000 | Calculated from schedules | 0.1023 | 1.3075 | 1.0000 | 1.0000 | Not calculated | 0.1023 | 0.0782 | ||
PSZ-FINE STORAGE | 3.0581 | 0.0000 | 30.0000 | 1.0000 | Calculated from schedules | 0.4247 | 3.0581 | 1.0000 | 1.0000 | Not calculated | 0.4247 | 0.1389 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
ZONE1 OFFICE | PSZ-OFFICE | 0.000000 | 12.7487 | 0.000432 | 236.88 | 0.1023 | 1.0000 | 0.1023 | 1.000 | 0.1023 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 0.000000 | 30.0000 | 0.000305 | 1393.41 | 0.4247 | 1.0000 | 0.4247 | 1.000 | 0.4247 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-OFFICE | 0.000000 | 12.75 | 0.000432 | 236.8796 | 0.1023 | 0.1023 | 0.1023 |
PSZ-FINE STORAGE | 0.000000 | 30.00 | 0.000305 | 1393.4097 | 0.4247 | 0.4247 | 0.4247 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.3075 | 1.3075 | 1.3075 | No | 0.1023 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 3.0581 | 3.0581 | 3.0581 | No | 0.4247 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 1.3075 | 1.3075 | 1.3075 | 1.3075 | 0.1023 | 1.0000 |
PSZ-FINE STORAGE | 3.0581 | 3.0581 | 3.0581 | 3.0581 | 0.4247 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.3075 | 1.3075 | 1.3075 | No | 0.1023 | 0.2589 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 3.0581 | 3.0581 | 3.0581 | No | 0.4247 | 0.4138 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 1.3075 | 1.3075 | 1.3075 | 1.3075 | 0.1023 | 1.0000 |
PSZ-FINE STORAGE | 3.0581 | 3.0581 | 3.0581 | 3.0581 | 0.4247 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695 |
Total gross floor area [m2] | 4835.13 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
ZONE1 OFFICE | 236.88 | 236.88 | 0.00 | 69.73 |
ZONE2 FINE STORAGE | 1393.41 | 1393.41 | 0.00 | 69.73 |
ZONE3 BULK STORAGE | 3204.84 | 3204.84 | 0.00 | 69.73 |
Totals | 4835.13 | 4835.13 | 0.00 |
Data | |
Number of hours heating loads not met | 33.67 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 33.67 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- General | 0.00 | 0.00 | 378.87 | 218353.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- General | 16.98 | 13500.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 157.81 | 15686.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 92.55 | 6958.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 139.29 | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- Ventilation (simple) | 3.14 | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 28.58 | 4080.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 26.05 | 2604.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 139.29 | 464.39 |
Natural Gas | 0.00 | 378.87 |
Additional | 0.00 | 0.00 |
Total | 139.29 | 843.26 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 32.64 |
Space Heating | 0.00 |
Space Cooling | 3.51 |
Fans (All) | 6.56 |
Service Water Heating | 5.39 |
Receptacle Equipment | 28.81 |
Miscellaneous (All) | 96.04 |
Subtotal | 96.04 |
Natural Gas [MJ/m2] | |
Space Heating | 78.36 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 78.36 |
Subtotal | 78.36 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 18.71 |
Space Heating | 44.93 |
Space Cooling | 2.01 |
Fans (All) | 3.76 |
Service Water Heating | 3.09 |
Receptacle Equipment | 16.52 |
Miscellaneous | 10.97 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
LTG_SCH_OFFICE | 2688. | 8760. |
LTG_SCH_BULK_STORAGE | 1777. | 8760. |
LTG_SCH_FINE_STORAGE | 1777. | 8760. |
OFFICE_PLUG_SCH | 4700. | 8760. |
BULK STORAGE PLUG SCHEDULE | 3744. | 7488. |
BLDG_OCC_SCH | 2861. | 3744. |
OFFICE PEOPLE SCHEDULE | 2861. | 3744. |
FANSCHED | 3432. | 3432. |
MINOA_MOTORIZEDDAMPER_SCHED | 3120. | 3120. |
OFFICE DHW SCHEDULE | 1825. | 5016. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 5550. | 8760. |
EXTERIOR LIGHT SCHEDULE | 5475. | 5475. |
ALWAYS OFF SCHEDULE | 0. | 0. |
OA DAMPER OFF DURING OFF HRS SCHEDULE | 2808. | 2808. |
OA DAMPER ALWAYS ON SCHEDULE | 8760. | 8760. |
MINOA_SCHED | 8760. | 8760. |
ALWAYS ON SCHEDULE | 8760. | 8760. |
EXTERIOR_LTG_SCH | 4380. | 4380. |
INFIL_DOOR_OPENING_SCH | 1154. | 3380. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 2600. | 2600. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 6935. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
BULK STORAGE HEATING SETPOINT SCHEDULE | ZONE3 BULK STORAGE HEATING SP | January | 10.00 | 365 | 10.00 | 365 |
OFFICE HEATING SCHEDULE | ZONE1 OFFICE DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
OFFICE COOLING SCHEDULE | ZONE1 OFFICE DUAL SP CONTROL | July | 23.90 | 365 | 29.40 | 365 |
FINE STORAGE HEATING SETPOINT SCHEDULE | ZONE2 FINE STORAGE DUAL SP CONTROL | January | 15.56 | 365 | 15.56 | 365 |
FINE STORAGE COOLING SETPOINT SCHEDULE | ZONE2 FINE STORAGE DUAL SP CONTROL | July | 26.70 | 365 | 26.70 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Heat Index HoursSafe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
ZONE1 OFFICE | 8408.00 | 352.00 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 8636.00 | 124.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 7119.67 | 1632.83 | 7.50 | 0.00 | 0.00 |
Min | 7119.67 | 124.00 | 0.00 | 0.00 | 0.00 |
Max | 8636.00 | 1632.83 | 7.50 | 0.00 | 0.00 |
Average | 8054.56 | 702.94 | 2.50 | 0.00 | 0.00 |
Sum | 24163.67 | 2108.83 | 7.50 | 0.00 | 0.00 |
Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
ZONE1 OFFICE | 33026.00 | 1.00 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 80509.50 | 2209.50 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 144769.50 | 46072.67 | 350.83 | 0.00 | 0.00 |
Min | 33026.00 | 1.00 | 0.00 | 0.00 | 0.00 |
Max | 144769.50 | 46072.67 | 350.83 | 0.00 | 0.00 |
Average | 86101.67 | 16094.39 | 116.94 | 0.00 | 0.00 |
Sum | 258305.00 | 48283.17 | 350.83 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
ZONE1 OFFICE | 8530.17 | 229.83 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 8489.33 | 270.67 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 7886.83 | 873.17 | 0.00 | 0.00 | 0.00 |
Min | 7886.83 | 229.83 | 0.00 | 0.00 | 0.00 |
Max | 8530.17 | 873.17 | 0.00 | 0.00 | 0.00 |
Average | 8302.11 | 457.89 | 0.00 | 0.00 | 0.00 |
Sum | 24906.33 | 1373.67 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
ZONE1 OFFICE | 33010.33 | 16.67 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 79553.50 | 3165.50 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 164078.67 | 27114.33 | 0.00 | 0.00 | 0.00 |
Min | 33010.33 | 16.67 | 0.00 | 0.00 | 0.00 |
Max | 164078.67 | 27114.33 | 0.00 | 0.00 | 0.00 |
Average | 92214.17 | 10098.83 | 0.00 | 0.00 | 0.00 |
Sum | 276642.50 | 30296.50 | 0.00 | 0.00 | 0.00 |
SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
None |
SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
CO2 Level HoursSafe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:46
Illuminance Level HoursA Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
ZONE1 OFFICE | 0.00 | 0.00 | 8760.00 | 0.00 |
ZONE2 FINE STORAGE | 0.00 | 0.00 | 8760.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 8760.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 8760.00 | 8760.00 | 0.00 |
Average | 0.00 | 2920.00 | 5840.00 | 0.00 |
Sum | 0.00 | 8760.00 | 17520.00 | 0.00 |
A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
ZONE1 OFFICE | 0.00 | 0.00 | 33027.00 | 0.00 |
ZONE2 FINE STORAGE | 0.00 | 0.00 | 82719.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 191193.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 191193.00 | 82719.00 | 0.00 |
Average | 0.00 | 63731.00 | 38582.00 | 0.00 |
Sum | 0.00 | 191193.00 | 115746.00 | 0.00 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015
For: Environment
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
For: Environment
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5B
For: Environment
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_CO_DENVER
For: Environment
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: ZoneCoolingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 39441529.26 | 1811.85 | 28-JAN-08:05 | -0.7 | -0.7 | 0.500270E+09 | 735.96 | 20-JAN-15:50 | -0.7 | -0.7 |
February | 23845291.05 | 1762.48 | 28-FEB-08:05 | -0.7 | -1.2 | 0.457725E+09 | 738.33 | 18-FEB-15:09 | -0.7 | -1.2 |
March | 0.175004E+09 | 2602.28 | 15-MAR-15:50 | 19.17 | 5.44 | 0.559576E+09 | 768.96 | 13-MAR-15:00 | 19.17 | 5.44 |
April | 0.108872E+09 | 2027.52 | 15-APR-07:05 | -3.8 | -5.4 | 0.520616E+09 | 768.97 | 19-APR-14:00 | 21.00 | 8.56 |
May | 0.144195E+10 | 5120.32 | 31-MAY-16:00 | 28.00 | 14.86 | 0.624753E+09 | 768.99 | 30-MAY-15:00 | 28.00 | 14.86 |
June | 0.599710E+10 | 26014.52 | 10-JUN-07:02 | 15.18 | 6.84 | 0.663934E+09 | 879.39 | 12-JUN-07:10 | 23.85 | 11.62 |
July | 0.593158E+10 | 21568.12 | 10-JUL-07:02 | 20.50 | 11.44 | 0.639380E+09 | 879.39 | 25-JUL-07:10 | 23.33 | 14.79 |
August | 0.631965E+10 | 23240.15 | 19-AUG-07:02 | 18.50 | 8.86 | 0.689590E+09 | 879.39 | 05-AUG-07:10 | 18.50 | 8.86 |
September | 0.453214E+10 | 23288.76 | 30-SEP-07:02 | 18.38 | 8.03 | 0.632842E+09 | 879.39 | 02-SEP-07:10 | 18.38 | 8.03 |
October | 0.913681E+09 | 5032.21 | 11-OCT-15:10 | 25.67 | 9.32 | 0.563950E+09 | 768.96 | 10-OCT-12:20 | 25.67 | 9.32 |
November | 0.114654E+09 | 1720.12 | 14-NOV-08:05 | 0.17 | 0.17 | 0.493402E+09 | 768.97 | 06-NOV-16:10 | 0.17 | 0.17 |
December | 25464355.75 | 1775.25 | 16-DEC-08:05 | -0.6 | -2.5 | 0.499234E+09 | 754.32 | 02-DEC-15:39 | -0.6 | -2.5 |
Annual Sum or Average | 0.256234E+11 | 0.684527E+10 | ||||||||
Minimum of Months | 23845291.05 | 1720.12 | -3.8 | -5.4 | 0.457725E+09 | 735.96 | -0.7 | -2.5 | ||
Maximum of Months | 0.631965E+10 | 26014.52 | 28.00 | 14.86 | 0.689590E+09 | 879.39 | 28.00 | 14.86 |
Report: ZoneCoolingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.149717E+10 | 5871.55 | 11-JAN-11:00 | -1.0 | -1.0 | 0.742506E+09 | 1348.47 | 20-JAN-14:39 | 20.33 | 6.84 |
February | 0.151391E+10 | 6324.27 | 03-FEB-09:45 | -4.0 | -5.6 | 0.669147E+09 | 1375.21 | 18-FEB-14:39 | 19.33 | 7.91 |
March | 0.135535E+10 | 5377.61 | 29-MAR-15:00 | 1.00 | -1.7 | 0.911394E+09 | 1822.94 | 15-MAR-15:09 | 1.00 | -1.7 |
April | 0.149369E+10 | 5891.24 | 22-APR-08:20 | 0.00 | -0.2 | 0.870283E+09 | 1609.33 | 21-APR-13:50 | 0.00 | -0.2 |
May | 0.111798E+10 | 4846.12 | 19-MAY-07:03 | 6.33 | 4.13 | 0.139622E+10 | 2246.80 | 17-MAY-13:00 | 6.33 | 4.13 |
June | 0.106533E+11 | 46557.62 | 15-JUN-17:06 | 31.63 | 14.49 | 0.190426E+10 | 2246.97 | 26-JUN-15:00 | 38.80 | 15.76 |
July | 0.111984E+11 | 48238.19 | 23-JUL-11:33 | 31.33 | 16.00 | 0.184457E+10 | 2246.92 | 25-JUL-14:30 | 23.00 | 16.20 |
August | 0.109779E+11 | 49284.34 | 20-AUG-14:33 | 28.00 | 14.12 | 0.198338E+10 | 2246.92 | 05-AUG-10:09 | 28.00 | 14.12 |
September | 0.517836E+10 | 45497.19 | 10-SEP-14:53 | 31.60 | 12.46 | 0.174236E+10 | 2246.86 | 01-SEP-12:20 | 31.60 | 12.46 |
October | 0.175643E+10 | 6950.98 | 12-OCT-08:20 | 1.33 | 0.89 | 0.109885E+10 | 2246.80 | 11-OCT-14:50 | 1.33 | 0.89 |
November | 0.148651E+10 | 5594.57 | 21-NOV-13:20 | 0.00 | -0.5 | 0.776101E+09 | 1536.67 | 09-NOV-13:39 | 0.00 | -0.5 |
December | 0.104546E+10 | 4834.36 | 07-DEC-14:30 | 1.00 | -4.2 | 0.717833E+09 | 1344.75 | 02-DEC-15:09 | 1.00 | -4.2 |
Annual Sum or Average | 0.492744E+11 | 0.146569E+11 | ||||||||
Minimum of Months | 0.104546E+10 | 4834.36 | -4.0 | -5.6 | 0.669147E+09 | 1344.75 | 0.00 | -4.2 | ||
Maximum of Months | 0.111984E+11 | 49284.34 | 31.63 | 16.00 | 0.198338E+10 | 2246.97 | 38.80 | 16.20 |
Report: ZoneCoolingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.50 | -1.8 | 0.868712E+09 | 1589.26 | 24-JAN-15:09 | 16.67 | 6.34 |
February | 0.00 | 0.00 | 01-FEB-00:03 | -5.3 | -5.3 | 0.743174E+09 | 1623.83 | 18-FEB-14:39 | 19.33 | 7.91 |
March | 0.00 | 0.00 | 01-MAR-00:10 | -1.1 | -1.1 | 0.111017E+10 | 2535.05 | 15-MAR-14:00 | 20.00 | 5.74 |
April | 0.00 | 0.00 | 01-APR-00:10 | 5.90 | 2.10 | 0.111209E+10 | 2116.44 | 12-APR-14:50 | 20.17 | 7.75 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 5.43 | 4.75 | 0.234041E+10 | 4071.93 | 31-MAY-15:00 | 28.00 | 14.86 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 | 11.26 | 0.493388E+10 | 9097.65 | 26-JUN-14:20 | 38.27 | 15.36 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 | 10.91 | 0.528102E+10 | 8717.02 | 17-JUL-13:09 | 35.83 | 14.79 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 | 15.43 | 0.554788E+10 | 8836.25 | 16-AUG-14:20 | 36.67 | 16.29 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 | 10.64 | 0.420449E+10 | 7063.84 | 09-SEP-13:09 | 32.43 | 12.96 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 10.30 | 8.03 | 0.204824E+10 | 4108.90 | 11-OCT-15:09 | 25.67 | 9.32 |
November | 0.00 | 0.00 | 01-NOV-00:05 | -5.7 | -5.7 | 0.948155E+09 | 1956.44 | 09-NOV-11:00 | 20.00 | 9.32 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 2.77 | -0.5 | 0.781852E+09 | 1650.87 | 04-DEC-14:39 | 19.33 | 6.32 |
Annual Sum or Average | 0.00 | 0.299201E+11 | ||||||||
Minimum of Months | 0.00 | 0.00 | -5.7 | -5.7 | 0.743174E+09 | 1589.26 | 16.67 | 5.74 | ||
Maximum of Months | 0.00 | 0.00 | 22.27 | 15.43 | 0.554788E+10 | 9097.65 | 38.27 | 16.29 |
Report: ZoneHeatingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.421492E+10 | 28853.44 | 06-JAN-06:42 | -7.0 |
February | 0.461465E+10 | 29470.18 | 06-FEB-06:32 | -10.0 |
March | 0.351024E+10 | 28568.24 | 29-MAR-06:02 | -7.7 |
April | 0.231319E+10 | 28669.86 | 17-APR-06:02 | -7.7 |
May | 0.444844E+09 | 28339.71 | 04-MAY-06:01 | 9.83 |
June | 36412269.59 | 1141.77 | 27-JUN-06:05 | 20.78 |
July | 34124497.45 | 1164.77 | 18-JUL-06:04 | 22.33 |
August | 45525473.12 | 1145.08 | 21-AUG-06:05 | 19.75 |
September | 71997628.49 | 10725.03 | 22-SEP-07:03 | 0.37 |
October | 0.159506E+10 | 28764.92 | 30-OCT-06:01 | -10.0 |
November | 0.304585E+10 | 28774.94 | 02-NOV-06:02 | -8.8 |
December | 0.557527E+10 | 29839.00 | 22-DEC-06:31 | -20.3 |
Annual Sum or Average | 0.255021E+11 | |||
Minimum of Months | 34124497.45 | 1141.77 | -20.3 | |
Maximum of Months | 0.557527E+10 | 29839.00 | 22.33 |
Report: ZoneHeatingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.129839E+11 | 88764.54 | 05-JAN-20:02 | -17.0 |
February | 0.148877E+11 | 90120.60 | 12-FEB-06:42 | -19.8 |
March | 0.967626E+10 | 90308.95 | 19-MAR-01:42 | -8.7 |
April | 0.635496E+10 | 88488.05 | 17-APR-05:42 | -8.0 |
May | 0.936061E+09 | 45990.45 | 02-MAY-06:02 | 0.17 |
June | 75431665.71 | 1176.25 | 28-JUN-06:15 | 17.17 |
July | 67905061.69 | 1276.25 | 27-JUL-06:25 | 21.50 |
August | 88924313.01 | 1303.59 | 24-AUG-07:00 | 15.00 |
September | 0.124476E+09 | 1748.48 | 26-SEP-11:30 | 28.00 |
October | 0.377815E+10 | 88527.14 | 31-OCT-23:42 | -5.9 |
November | 0.800859E+10 | 88836.23 | 01-NOV-03:42 | -3.1 |
December | 0.208757E+11 | 90838.17 | 22-DEC-06:01 | -20.8 |
Annual Sum or Average | 0.778581E+11 | |||
Minimum of Months | 67905061.69 | 1176.25 | -20.8 | |
Maximum of Months | 0.208757E+11 | 90838.17 | 28.00 |
Report: ZoneHeatingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.235575E+11 | 52441.59 | 08-JAN-03:00 | -12.0 |
February | 0.384346E+11 | 83188.23 | 12-FEB-05:51 | -19.0 |
March | 0.184746E+11 | 93842.76 | 19-MAR-06:47 | -15.2 |
April | 0.101125E+11 | 52982.37 | 16-APR-16:00 | -3.0 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 5.43 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
October | 0.387589E+10 | 47005.78 | 31-OCT-24:00 | -5.8 |
November | 0.129472E+11 | 79629.63 | 30-NOV-05:52 | -12.0 |
December | 0.631305E+11 | 94443.06 | 21-DEC-18:00 | -22.0 |
Annual Sum or Average | 0.170533E+12 | |||
Minimum of Months | 0.00 | 0.00 | -22.0 | |
Maximum of Months | 0.631305E+11 | 94443.06 | 22.27 |
Report: ZoneElectricSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.158980E+10 | 1285.93 | 02-JAN-16:49 | 0.267964E+10 | 1912.50 | 02-JAN-08:09 |
February | 0.143428E+10 | 1279.81 | 06-FEB-16:00 | 0.243949E+10 | 1912.50 | 01-FEB-08:09 |
March | 0.161050E+10 | 1265.99 | 18-MAR-07:10 | 0.277107E+10 | 1912.50 | 01-MAR-08:09 |
April | 0.149864E+10 | 1254.02 | 03-APR-07:10 | 0.263007E+10 | 1912.50 | 01-APR-07:10 |
May | 0.151948E+10 | 1200.98 | 19-MAY-07:10 | 0.272536E+10 | 1912.50 | 01-MAY-07:10 |
June | 0.149658E+10 | 1213.68 | 17-JUN-07:10 | 0.267579E+10 | 1912.50 | 01-JUN-07:10 |
July | 0.148930E+10 | 1203.76 | 28-JUL-07:10 | 0.267964E+10 | 1912.50 | 01-JUL-07:10 |
August | 0.157392E+10 | 1220.10 | 28-AUG-15:00 | 0.277107E+10 | 1912.50 | 01-AUG-07:10 |
September | 0.149905E+10 | 1228.72 | 22-SEP-07:10 | 0.263007E+10 | 1912.50 | 01-SEP-07:10 |
October | 0.155726E+10 | 1272.14 | 30-OCT-07:10 | 0.267964E+10 | 1912.50 | 02-OCT-07:10 |
November | 0.152708E+10 | 1285.93 | 06-NOV-16:49 | 0.258435E+10 | 1912.50 | 01-NOV-07:10 |
December | 0.159526E+10 | 1285.93 | 01-DEC-16:30 | 0.267964E+10 | 1912.50 | 01-DEC-08:09 |
Annual Sum or Average | 0.183912E+11 | 0.319458E+11 | ||||
Minimum of Months | 0.143428E+10 | 1200.98 | 0.243949E+10 | 1912.50 | ||
Maximum of Months | 0.161050E+10 | 1285.93 | 0.277107E+10 | 1912.50 |
Report: ZoneElectricSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
January | 0.606765E+10 | 5995.09 | 02-JAN-09:09 | 0.00 | 0.00 |
February | 0.543900E+10 | 5995.09 | 01-FEB-15:00 | 0.00 | 0.00 |
March | 0.556115E+10 | 5495.50 | 02-MAR-15:50 | 0.00 | 0.00 |
April | 0.474686E+10 | 5495.50 | 01-APR-08:09 | 0.00 | 0.00 |
May | 0.451935E+10 | 5289.79 | 16-MAY-07:10 | 0.00 | 0.00 |
June | 0.459602E+10 | 4995.91 | 05-JUN-08:09 | 0.00 | 0.00 |
July | 0.443570E+10 | 5289.79 | 01-JUL-07:10 | 0.00 | 0.00 |
August | 0.505494E+10 | 5289.79 | 30-AUG-07:10 | 0.00 | 0.00 |
September | 0.493724E+10 | 5995.09 | 23-SEP-08:09 | 0.00 | 0.00 |
October | 0.552233E+10 | 5995.09 | 28-OCT-08:09 | 0.00 | 0.00 |
November | 0.577668E+10 | 5995.09 | 01-NOV-08:09 | 0.00 | 0.00 |
December | 0.610078E+10 | 5995.09 | 01-DEC-14:09 | 0.00 | 0.00 |
Annual Sum or Average | 0.627577E+11 | 0.00 | 0.00 | ||
Minimum of Months | 0.443570E+10 | 4995.91 | 0.00 | 0.00 | |
Maximum of Months | 0.610078E+10 | 5995.09 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.770279E+10 | 8418.38 | 02-JAN-15:00 | 0.885613E+10 | 8200.12 | 02-JAN-08:09 |
February | 0.663398E+10 | 8418.38 | 02-FEB-15:00 | 0.814764E+10 | 8200.12 | 01-FEB-08:09 |
March | 0.661444E+10 | 7427.98 | 02-MAR-16:00 | 0.957200E+10 | 8200.12 | 01-MAR-08:09 |
April | 0.571561E+10 | 6313.78 | 01-APR-08:09 | 0.885613E+10 | 8200.12 | 01-APR-07:10 |
May | 0.565636E+10 | 5570.98 | 09-MAY-15:50 | 0.921037E+10 | 8200.12 | 01-MAY-07:10 |
June | 0.556638E+10 | 4951.99 | 16-JUN-06:10 | 0.921037E+10 | 8200.12 | 01-JUN-07:10 |
July | 0.551163E+10 | 6189.98 | 12-JUL-07:10 | 0.885613E+10 | 8200.12 | 01-JUL-07:10 |
August | 0.598361E+10 | 5612.25 | 29-AUG-14:00 | 0.956462E+10 | 8200.12 | 01-AUG-07:10 |
September | 0.590898E+10 | 6313.78 | 23-SEP-14:39 | 0.884875E+10 | 8200.12 | 01-SEP-07:10 |
October | 0.658176E+10 | 7427.98 | 12-OCT-07:10 | 0.886351E+10 | 8200.12 | 02-OCT-07:10 |
November | 0.713512E+10 | 8418.38 | 07-NOV-15:30 | 0.850188E+10 | 8200.12 | 01-NOV-07:10 |
December | 0.764765E+10 | 8418.38 | 01-DEC-15:09 | 0.885613E+10 | 8200.12 | 01-DEC-08:09 |
Annual Sum or Average | 0.766583E+11 | 0.107344E+12 | ||||
Minimum of Months | 0.551163E+10 | 4951.99 | 0.814764E+10 | 8200.12 | ||
Maximum of Months | 0.770279E+10 | 8418.38 | 0.957200E+10 | 8200.12 |
Report: SpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.138726E+10 | 0.158980E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.276688E+10 |
February | 0.127628E+10 | 0.143428E+10 | 0.243949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.330843E+10 |
March | 0.149825E+10 | 0.161050E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3178.78 | 0.313653E+10 |
April | 0.138726E+10 | 0.149864E+10 | 0.263007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.270195E+10 |
May | 0.144276E+10 | 0.151948E+10 | 0.272536E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32683671.60 | 0.161229E+10 |
June | 0.144276E+10 | 0.149658E+10 | 0.267579E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.456332E+09 | 0.704371E+09 |
July | 0.138726E+10 | 0.148930E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.386817E+09 | 0.699021E+09 |
August | 0.149825E+10 | 0.157392E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.389949E+09 | 0.809637E+09 |
September | 0.138726E+10 | 0.149905E+10 | 0.263007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.169814E+09 | 0.112344E+10 |
October | 0.138726E+10 | 0.155726E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4501856.20 | 0.264295E+10 |
November | 0.133177E+10 | 0.152708E+10 | 0.258435E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 76149.11 | 0.280346E+10 |
December | 0.138726E+10 | 0.159526E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.419271E+10 |
Annual Sum or Average | 0.168137E+11 | 0.183912E+11 | 0.319458E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144018E+10 | 0.265017E+11 |
Minimum of Months | 0.127628E+10 | 0.143428E+10 | 0.243949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.699021E+09 |
Maximum of Months | 0.149825E+10 | 0.161050E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.456332E+09 | 0.419271E+10 |
Report: SpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.326447E+10 | 0.606765E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 312051.27 | 0.495389E+10 |
February | 0.300332E+10 | 0.543900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.802847E+10 |
March | 0.352563E+10 | 0.556115E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54582.61 | 0.839056E+10 |
April | 0.326447E+10 | 0.474686E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 247230.93 | 0.798811E+10 |
May | 0.339505E+10 | 0.451935E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18136869.32 | 0.458355E+10 |
June | 0.339505E+10 | 0.459602E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.557093E+09 | 0.273972E+10 |
July | 0.326447E+10 | 0.443570E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.588925E+09 | 0.279916E+10 |
August | 0.352563E+10 | 0.505494E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.366724E+09 | 0.288130E+10 |
September | 0.326447E+10 | 0.493724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.125771E+09 | 0.399007E+10 |
October | 0.326447E+10 | 0.552233E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39776.85 | 0.672414E+10 |
November | 0.313390E+10 | 0.577668E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2499454.54 | 0.566259E+10 |
December | 0.326447E+10 | 0.610078E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4768679.09 | 0.114365E+11 |
Annual Sum or Average | 0.395654E+11 | 0.627577E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.166457E+10 | 0.701781E+11 |
Minimum of Months | 0.300332E+10 | 0.443570E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.273972E+10 |
Maximum of Months | 0.352563E+10 | 0.610078E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.588925E+09 | 0.114365E+11 |
Report: SpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.750829E+10 | 0.770279E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.424804E+09 | 0.174823E+11 |
February | 0.690763E+10 | 0.663398E+10 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.324355E+09 | 0.292067E+11 |
March | 0.810895E+10 | 0.661444E+10 | 0.957200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.806826E+09 | 0.288154E+11 |
April | 0.750829E+10 | 0.571561E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.175626E+10 | 0.255958E+11 |
May | 0.780862E+10 | 0.565636E+10 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.197434E+10 | 0.153415E+11 |
June | 0.780862E+10 | 0.556638E+10 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151117E+10 | 0.143207E+11 |
July | 0.750829E+10 | 0.551163E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238384E+09 | 0.189386E+11 |
August | 0.810895E+10 | 0.598361E+10 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156475E+09 | 0.185204E+11 |
September | 0.750829E+10 | 0.590898E+10 | 0.884875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.441723E+09 | 0.219229E+11 |
October | 0.750829E+10 | 0.658176E+10 | 0.886351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120106E+09 | 0.296423E+11 |
November | 0.720796E+10 | 0.713512E+10 | 0.850188E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.472107E+09 | 0.208842E+11 |
December | 0.750829E+10 | 0.764765E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.997346E+09 | 0.429925E+11 |
Annual Sum or Average | 0.910005E+11 | 0.766583E+11 | 0.107344E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.922390E+10 | 0.283663E+12 |
Minimum of Months | 0.690763E+10 | 0.551163E+10 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120106E+09 | 0.143207E+11 |
Maximum of Months | 0.810895E+10 | 0.770279E+10 | 0.957200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.197434E+10 | 0.429925E+11 |
Report: PeakSpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1680.92 | 02-JAN-08:09 | 1285.93 | 02-JAN-16:49 | 1912.50 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 13399.91 | 05-JAN-18:00 |
February | 1680.92 | 01-FEB-08:09 | 1279.81 | 06-FEB-16:00 | 1912.50 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 11056.98 | 13-FEB-07:10 |
March | 1680.92 | 01-MAR-08:09 | 1265.99 | 18-MAR-07:10 | 1912.50 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5.30 | 14-MAR-13:00 | 10629.25 | 27-MAR-16:10 |
April | 1680.92 | 01-APR-07:10 | 1254.02 | 03-APR-07:10 | 1912.50 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 10436.46 | 17-APR-06:10 |
May | 1680.92 | 01-MAY-07:10 | 1200.98 | 19-MAY-07:10 | 1912.50 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1323.48 | 31-MAY-16:10 | 7821.43 | 02-MAY-06:10 |
June | 1680.92 | 01-JUN-07:10 | 1213.68 | 17-JUN-07:10 | 1912.50 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4472.47 | 26-JUN-17:00 | 4797.31 | 09-JUN-06:05 |
July | 1680.92 | 01-JUL-07:10 | 1203.76 | 28-JUL-07:10 | 1912.50 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3491.93 | 17-JUL-12:00 | 4873.60 | 03-JUL-06:05 |
August | 1680.92 | 01-AUG-07:10 | 1220.10 | 28-AUG-15:00 | 1912.50 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3870.27 | 16-AUG-16:10 | 4214.06 | 15-AUG-06:05 |
September | 1680.92 | 01-SEP-07:10 | 1228.72 | 22-SEP-07:10 | 1912.50 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2323.54 | 12-SEP-16:10 | 8285.62 | 21-SEP-16:02 |
October | 1680.92 | 02-OCT-07:10 | 1272.14 | 30-OCT-07:10 | 1912.50 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 362.37 | 10-OCT-17:00 | 11048.73 | 30-OCT-16:10 |
November | 1680.92 | 01-NOV-07:10 | 1285.93 | 06-NOV-16:49 | 1912.50 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7.19 | 05-NOV-12:20 | 12066.21 | 29-NOV-18:00 |
December | 1680.92 | 01-DEC-08:09 | 1285.93 | 01-DEC-16:30 | 1912.50 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 18363.96 | 21-DEC-18:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1680.92 | 1200.98 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4214.06 | |||||
Maximum of Months | 1680.92 | 1285.93 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 4472.47 | 18363.96 |
Report: PeakSpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 3955.50 | 02-JAN-08:09 | 5995.09 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.02 | 23-JAN-13:00 | 7912.74 | 07-JAN-08:00 |
February | 3955.50 | 01-FEB-08:09 | 5995.09 | 01-FEB-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 11585.04 | 11-FEB-16:10 |
March | 3955.50 | 01-MAR-08:09 | 5495.50 | 02-MAR-15:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.69 | 14-MAR-13:00 | 21647.76 | 19-MAR-06:51 |
April | 3955.50 | 01-APR-07:10 | 5495.50 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75.76 | 19-APR-13:00 | 15527.39 | 14-APR-07:00 |
May | 3955.50 | 01-MAY-07:10 | 5289.79 | 16-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 643.38 | 04-MAY-15:10 | 8591.38 | 02-MAY-06:03 |
June | 3955.50 | 01-JUN-07:10 | 4995.91 | 05-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3882.12 | 06-JUN-16:40 | 6330.27 | 20-JUN-17:00 |
July | 3955.50 | 01-JUL-07:10 | 5289.79 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3797.35 | 15-JUL-15:10 | 5127.37 | 03-JUL-03:00 |
August | 3955.50 | 01-AUG-07:10 | 5289.79 | 30-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4031.59 | 02-AUG-16:00 | 6273.33 | 27-AUG-18:00 |
September | 3955.50 | 01-SEP-07:10 | 5995.09 | 23-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2015.21 | 09-SEP-15:10 | 11771.95 | 21-SEP-15:05 |
October | 3955.50 | 02-OCT-07:10 | 5995.09 | 28-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.41 | 11-OCT-14:00 | 11183.03 | 29-OCT-19:00 |
November | 3955.50 | 01-NOV-07:10 | 5995.09 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 214.94 | 05-NOV-15:00 | 13380.04 | 01-NOV-07:00 |
December | 3955.50 | 01-DEC-08:09 | 5995.09 | 01-DEC-14:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 194.73 | 02-DEC-12:40 | 21146.20 | 21-DEC-18:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 3955.50 | 4995.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5127.37 | ||||
Maximum of Months | 3955.50 | 5995.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4031.59 | 21647.76 |
Report: PeakSpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 9097.65 | 02-JAN-08:09 | 8418.38 | 02-JAN-15:00 | 8200.12 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 7508.93 | 19-JAN-14:00 | 33332.09 | 07-JAN-12:00 |
February | 9097.65 | 01-FEB-08:09 | 8418.38 | 02-FEB-15:00 | 8200.12 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 8829.07 | 18-FEB-14:00 | 58167.19 | 11-FEB-15:00 |
March | 9097.65 | 01-MAR-08:09 | 7427.98 | 02-MAR-16:00 | 8200.12 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 9330.93 | 31-MAR-14:00 | 84926.40 | 19-MAR-06:51 |
April | 9097.65 | 01-APR-07:10 | 6313.78 | 01-APR-08:09 | 8200.12 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18521.06 | 07-APR-16:00 | 49679.67 | 14-APR-07:03 |
May | 9097.65 | 01-MAY-07:10 | 5570.98 | 09-MAY-15:50 | 8200.12 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13067.37 | 17-MAY-15:00 | 44318.88 | 26-MAY-11:00 |
June | 9097.65 | 01-JUN-07:10 | 4951.99 | 16-JUN-06:10 | 8200.12 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16130.02 | 06-JUN-14:00 | 28098.65 | 20-JUN-17:00 |
July | 9097.65 | 01-JUL-07:10 | 6189.98 | 12-JUL-07:10 | 8200.12 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2980.45 | 16-JUL-11:53 | 27448.55 | 03-JUL-03:00 |
August | 9097.65 | 01-AUG-07:10 | 5612.25 | 29-AUG-14:00 | 8200.12 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5158.02 | 02-AUG-12:53 | 32196.47 | 27-AUG-18:00 |
September | 9097.65 | 01-SEP-07:10 | 6313.78 | 23-SEP-14:39 | 8200.12 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8926.62 | 26-SEP-12:10 | 58285.50 | 21-SEP-14:50 |
October | 9097.65 | 02-OCT-07:10 | 7427.98 | 12-OCT-07:10 | 8200.12 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5350.91 | 11-OCT-14:00 | 47527.95 | 03-OCT-15:00 |
November | 9097.65 | 01-NOV-07:10 | 8418.38 | 07-NOV-15:30 | 8200.12 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9332.11 | 07-NOV-14:00 | 47770.52 | 01-NOV-10:00 |
December | 9097.65 | 01-DEC-08:09 | 8418.38 | 01-DEC-15:09 | 8200.12 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 21921.16 | 02-DEC-12:00 | 73433.89 | 21-DEC-19:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 9097.65 | 4951.99 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 2980.45 | 27448.55 | |||||
Maximum of Months | 9097.65 | 8418.38 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 21921.16 | 84926.40 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1811.85 | 28-JAN-08:05 | 6723.69 | 4911.18 | 7650.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 612.04 |
February | 1762.48 | 28-FEB-08:05 | 6723.69 | 4629.64 | 7650.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1562.12 |
March | 2602.28 | 15-MAR-15:50 | 1680.92 | 1035.17 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 426.96 |
April | 2027.52 | 15-APR-07:05 | 6723.69 | 4890.94 | 7650.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1675.57 |
May | 5120.32 | 31-MAY-16:00 | 1680.92 | 1035.17 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 389.12 | 0.00 |
June | 26014.52 | 10-JUN-07:02 | 8404.61 | 5617.94 | 9562.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 451.24 |
July | 21568.12 | 10-JUL-07:02 | 8404.61 | 5413.87 | 9562.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 399.24 |
August | 23240.15 | 19-AUG-07:02 | 8404.61 | 5743.29 | 9562.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 213.96 |
September | 23288.76 | 30-SEP-07:02 | 8404.61 | 5963.60 | 9562.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 178.17 |
October | 5032.21 | 11-OCT-15:10 | 1680.92 | 1035.17 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 187.77 | 0.00 |
November | 1720.12 | 14-NOV-08:05 | 6723.69 | 4898.35 | 7650.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1138.25 |
December | 1775.25 | 16-DEC-08:05 | 6723.69 | 4932.31 | 7650.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1086.61 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1720.12 | 1680.92 | 1035.17 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 26014.52 | 8404.61 | 5963.60 | 9562.50 | 0.00 | 0.00 | 0.00 | 0.00 | 389.12 | 1675.57 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5871.55 | 11-JAN-11:00 | 3955.50 | 4995.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 256.84 |
February | 6324.27 | 03-FEB-09:45 | 7911.00 | 9991.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1203.03 |
March | 5377.61 | 29-MAR-15:00 | 3955.50 | 3996.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1518.44 |
April | 5891.24 | 22-APR-08:20 | 3955.50 | 4995.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2656.13 |
May | 4846.12 | 19-MAY-07:03 | 15822.00 | 17632.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4210.17 |
June | 46557.62 | 15-JUN-17:06 | 0.00 | 3232.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2499.12 | 0.00 |
July | 48238.19 | 23-JUL-11:33 | 0.00 | 1057.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 343.41 | 0.00 |
August | 49284.34 | 20-AUG-14:33 | 0.00 | 1410.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 338.34 | 0.00 |
September | 45497.19 | 10-SEP-14:53 | 0.00 | 1763.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1347.40 | 0.00 |
October | 6950.98 | 12-OCT-08:20 | 3955.50 | 5495.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2375.24 |
November | 5594.57 | 21-NOV-13:20 | 3955.50 | 4496.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 734.54 |
December | 4834.36 | 07-DEC-14:30 | 3955.50 | 5995.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1964.82 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 4834.36 | 0.00 | 1057.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 49284.34 | 15822.00 | 17632.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2499.12 | 4210.17 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:05 | 0.00 | 1980.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2798.87 |
February | 0.00 | 01-FEB-00:03 | 0.00 | 2971.19 | 6150.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9434.83 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 990.40 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8628.08 |
April | 0.00 | 01-APR-00:10 | 0.00 | 990.40 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3841.25 |
May | 0.00 | 01-MAY-00:10 | 0.00 | 990.40 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6076.15 |
June | 0.00 | 01-JUN-00:10 | 0.00 | 990.40 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3961.43 |
July | 0.00 | 01-JUL-00:10 | 0.00 | 990.40 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9960.31 |
August | 0.00 | 01-AUG-00:10 | 0.00 | 990.40 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12529.81 |
September | 0.00 | 01-SEP-00:10 | 0.00 | 990.40 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6638.54 |
October | 0.00 | 01-OCT-00:10 | 0.00 | 990.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10692.22 |
November | 0.00 | 01-NOV-00:05 | 0.00 | 1980.79 | 4100.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28831.63 |
December | 0.00 | 01-DEC-00:03 | 0.00 | 2971.19 | 6150.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9580.58 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 990.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2798.87 | |
Maximum of Months | 0.00 | 0.00 | 2971.19 | 6150.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28831.63 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
January | 0.417802E+11 | 35527.21 | 05-JAN-16:49 | 0.575587E+11 | 115588.57 | 05-JAN-17:00 |
February | 0.371386E+11 | 30274.74 | 06-FEB-15:00 | 0.793145E+11 | 150860.22 | 12-FEB-06:19 |
March | 0.392955E+11 | 28046.92 | 18-MAR-07:19 | 0.443748E+11 | 181825.00 | 19-MAR-07:10 |
April | 0.347637E+11 | 27551.78 | 03-APR-08:09 | 0.260431E+11 | 102845.18 | 16-APR-15:50 |
May | 0.343025E+11 | 25252.35 | 09-MAY-15:50 | 0.141450E+10 | 35064.42 | 02-MAY-06:10 |
June | 0.389481E+11 | 39150.45 | 26-JUN-15:30 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 0.393541E+11 | 34699.82 | 15-JUL-14:39 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 0.415153E+11 | 37633.72 | 16-AUG-14:39 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 0.374411E+11 | 33557.47 | 12-SEP-15:50 | 43413867.25 | 7144.51 | 22-SEP-06:19 |
October | 0.381689E+11 | 28544.21 | 30-OCT-15:00 | 0.139747E+11 | 94986.69 | 31-OCT-23:49 |
November | 0.392173E+11 | 35461.74 | 28-NOV-16:40 | 0.346883E+11 | 148314.81 | 30-NOV-06:10 |
December | 0.424614E+11 | 35932.54 | 21-DEC-16:49 | 0.121457E+12 | 218353.45 | 21-DEC-17:00 |
Annual Sum or Average | 0.464387E+12 | 0.378869E+12 | ||||
Minimum of Months | 0.343025E+11 | 25252.35 | 0.00 | 0.00 | ||
Maximum of Months | 0.424614E+11 | 39150.45 | 0.121457E+12 | 218353.45 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.153602E+11 | 0.978421E+10 | 0.115358E+11 | 0.00 | 0.281748E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.228254E+10 | 0.00 |
February | 0.135073E+11 | 0.814943E+10 | 0.105871E+11 | 0.00 | 0.280907E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.208575E+10 | 0.00 |
March | 0.137861E+11 | 0.805161E+10 | 0.123431E+11 | 0.00 | 0.275814E+10 | 0.00 | 0.00 | 12034997.80 | 0.00 | 0.00 | 0.00 | 0.234458E+10 | 0.00 |
April | 0.119611E+11 | 0.680808E+10 | 0.114862E+11 | 0.00 | 0.231228E+10 | 0.00 | 0.00 | 96.82 | 0.00 | 0.00 | 0.00 | 0.219604E+10 | 0.00 |
May | 0.116952E+11 | 0.624069E+10 | 0.119357E+11 | 0.00 | 0.197640E+10 | 0.00 | 0.00 | 0.235455E+09 | 0.00 | 0.00 | 0.00 | 0.221900E+10 | 0.00 |
June | 0.116590E+11 | 0.564686E+10 | 0.118862E+11 | 0.00 | 0.286517E+10 | 0.00 | 0.00 | 0.477630E+10 | 0.00 | 0.00 | 0.00 | 0.211466E+10 | 0.00 |
July | 0.114366E+11 | 0.598155E+10 | 0.115358E+11 | 0.00 | 0.332641E+10 | 0.00 | 0.00 | 0.497695E+10 | 0.00 | 0.00 | 0.00 | 0.209675E+10 | 0.00 |
August | 0.126125E+11 | 0.665719E+10 | 0.123357E+11 | 0.00 | 0.307438E+10 | 0.00 | 0.00 | 0.469702E+10 | 0.00 | 0.00 | 0.00 | 0.213856E+10 | 0.00 |
September | 0.123453E+11 | 0.736335E+10 | 0.114788E+11 | 0.00 | 0.199418E+10 | 0.00 | 0.00 | 0.220365E+10 | 0.00 | 0.00 | 0.00 | 0.205585E+10 | 0.00 |
October | 0.136614E+11 | 0.862358E+10 | 0.115432E+11 | 0.00 | 0.212006E+10 | 0.00 | 0.00 | 75193819.00 | 0.00 | 0.00 | 0.00 | 0.214560E+10 | 0.00 |
November | 0.144389E+11 | 0.921284E+10 | 0.110862E+11 | 0.00 | 0.235767E+10 | 0.00 | 0.00 | 427087.61 | 0.00 | 0.00 | 0.00 | 0.212126E+10 | 0.00 |
December | 0.153437E+11 | 0.100264E+11 | 0.115358E+11 | 0.00 | 0.330823E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.224736E+10 | 0.00 |
Annual Sum or Average | 0.157807E+12 | 0.925458E+11 | 0.139290E+12 | 0.00 | 0.317195E+11 | 0.00 | 0.00 | 0.169770E+11 | 0.00 | 0.00 | 0.00 | 0.260479E+11 | 0.00 |
Minimum of Months | 0.114366E+11 | 0.564686E+10 | 0.105871E+11 | 0.00 | 0.197640E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.205585E+10 | 0.00 |
Maximum of Months | 0.153602E+11 | 0.100264E+11 | 0.123431E+11 | 0.00 | 0.332641E+10 | 0.00 | 0.00 | 0.497695E+10 | 0.00 | 0.00 | 0.00 | 0.234458E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
January | 0.00 | 0.00 | 0.575587E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.793145E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.443748E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.260431E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.141450E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 43413867.25 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.139747E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.346883E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.121457E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.378869E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.121457E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 15686.07 | 04-JAN-15:00 | 6958.21 | 01-JAN-06:10 | 10112.62 | 02-JAN-08:09 | 0.00 | 3434.34 | 05-JAN-17:00 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 15674.66 | 06-FEB-15:00 | 6958.21 | 01-FEB-06:10 | 10112.62 | 01-FEB-08:09 | 0.00 | 3265.15 | 06-FEB-07:10 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 13983.76 | 18-MAR-07:10 | 6958.21 | 01-MAR-06:10 | 10112.62 | 01-MAR-08:09 | 0.00 | 3011.78 | 29-MAR-06:10 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 13038.99 | 03-APR-08:09 | 6958.21 | 01-APR-05:10 | 10112.62 | 01-APR-07:10 | 0.00 | 3134.80 | 17-APR-06:10 | 0.00 | 0.00 | 01-APR-00:10 |
May | 11430.02 | 16-MAY-07:10 | 6958.21 | 01-MAY-18:49 | 10112.62 | 01-MAY-07:10 | 0.00 | 2569.24 | 02-MAY-06:10 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 11014.64 | 17-JUN-07:10 | 6958.21 | 01-JUN-19:19 | 10112.62 | 01-JUN-07:10 | 0.00 | 5121.09 | 26-JUN-15:09 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 12673.53 | 12-JUL-07:10 | 6958.21 | 01-JUL-19:30 | 10112.62 | 01-JUL-07:10 | 0.00 | 4574.61 | 17-JUL-11:00 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 11808.85 | 29-AUG-14:00 | 6958.21 | 01-AUG-19:10 | 10112.62 | 01-AUG-07:10 | 0.00 | 4640.15 | 16-AUG-16:10 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 12825.79 | 25-SEP-08:09 | 6958.21 | 01-SEP-05:10 | 10112.62 | 01-SEP-07:10 | 0.00 | 4254.85 | 12-SEP-16:10 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 14261.83 | 30-OCT-08:09 | 6958.21 | 01-OCT-05:10 | 10112.62 | 02-OCT-07:10 | 0.00 | 3168.22 | 31-OCT-16:00 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 15678.01 | 20-NOV-15:30 | 6958.21 | 01-NOV-05:10 | 10112.62 | 01-NOV-07:10 | 0.00 | 3255.14 | 29-NOV-17:00 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 15682.39 | 26-DEC-15:00 | 6958.21 | 01-DEC-06:10 | 10112.62 | 01-DEC-08:09 | 0.00 | 4080.13 | 21-DEC-17:00 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||||
Minimum of Months | 11014.64 | 6958.21 | 10112.62 | 0.00 | 2569.24 | 0.00 | 0.00 | |||||
Maximum of Months | 15686.07 | 6958.21 | 10112.62 | 0.00 | 5121.09 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 2593.78 | 31-JAN-12:50 | 0.00 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 2604.94 | 13-FEB-12:00 | 0.00 |
March | 544.14 | 13-MAR-15:00 | 0.00 | 0.00 | 0.00 | 2589.47 | 01-MAR-12:50 | 0.00 |
April | 0.06 | 20-APR-12:39 | 0.00 | 0.00 | 0.00 | 2470.71 | 01-APR-11:20 | 0.00 |
May | 2175.15 | 31-MAY-15:50 | 0.00 | 0.00 | 0.00 | 2258.97 | 01-MAY-11:00 | 0.00 |
June | 13500.51 | 26-JUN-15:09 | 0.00 | 0.00 | 0.00 | 1908.73 | 08-JUN-11:00 | 0.00 |
July | 10354.85 | 15-JUL-15:09 | 0.00 | 0.00 | 0.00 | 1800.24 | 01-JUL-11:30 | 0.00 |
August | 11136.45 | 16-AUG-16:10 | 0.00 | 0.00 | 0.00 | 1789.08 | 31-AUG-11:09 | 0.00 |
September | 7366.28 | 12-SEP-15:00 | 0.00 | 0.00 | 0.00 | 1800.67 | 29-SEP-11:00 | 0.00 |
October | 1797.79 | 11-OCT-14:09 | 0.00 | 0.00 | 0.00 | 2000.02 | 30-OCT-11:20 | 0.00 |
November | 115.72 | 07-NOV-14:00 | 0.00 | 0.00 | 0.00 | 2274.00 | 30-NOV-12:30 | 0.00 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 2479.90 | 30-DEC-12:00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1789.08 | 0.00 | ||
Maximum of Months | 13500.51 | 0.00 | 0.00 | 0.00 | 2604.94 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 35527.21 | 05-JAN-16:49 | 14003.70 | 10112.62 | 6958.21 | 0.00 | 2832.23 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 30274.74 | 06-FEB-15:00 | 15674.66 | 10112.62 | 0.00 | 0.00 | 2657.69 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 28046.92 | 18-MAR-07:19 | 13978.80 | 10112.62 | 0.00 | 0.00 | 2298.35 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 27551.78 | 03-APR-08:09 | 13038.99 | 10112.62 | 0.00 | 0.00 | 2708.21 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 25252.35 | 09-MAY-15:50 | 11014.32 | 10112.62 | 0.00 | 0.00 | 1887.97 | 0.00 | 0.00 | 624.98 | 0.00 |
June | 39150.45 | 26-JUN-15:30 | 9335.50 | 10112.62 | 0.00 | 0.00 | 5020.44 | 0.00 | 0.00 | 13077.53 | 0.00 |
July | 34699.82 | 15-JUL-14:39 | 8741.50 | 10112.62 | 0.00 | 0.00 | 4295.13 | 0.00 | 0.00 | 9794.13 | 0.00 |
August | 37633.72 | 16-AUG-14:39 | 10453.52 | 10112.62 | 0.00 | 0.00 | 4525.56 | 0.00 | 0.00 | 10790.23 | 0.00 |
September | 33557.47 | 12-SEP-15:50 | 10395.32 | 10112.62 | 0.00 | 0.00 | 4231.73 | 0.00 | 0.00 | 7216.12 | 0.00 |
October | 28544.21 | 30-OCT-15:00 | 13979.94 | 10112.62 | 0.00 | 0.00 | 2842.60 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 35461.74 | 28-NOV-16:40 | 14003.70 | 10112.62 | 6958.21 | 0.00 | 2772.88 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 35932.54 | 21-DEC-16:49 | 14003.70 | 10112.62 | 6958.21 | 0.00 | 3239.89 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 25252.35 | 8741.50 | 10112.62 | 0.00 | 0.00 | 1887.97 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 39150.45 | 15674.66 | 10112.62 | 6958.21 | 0.00 | 5020.44 | 0.00 | 0.00 | 13077.53 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | |
January | 0.00 | 0.00 | 115588.57 | 05-JAN-17:00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 150860.22 | 12-FEB-06:19 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 181825.00 | 19-MAR-07:10 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 102845.18 | 16-APR-15:50 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 35064.42 | 02-MAY-06:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 7144.51 | 22-SEP-06:19 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 94986.69 | 31-OCT-23:49 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 148314.81 | 30-NOV-06:10 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 218353.45 | 21-DEC-17:00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 218353.45 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 4.00 | 16.42 | 3.00 | 16.63 | 0.00 | 16.63 | 0.00 | 16.63 |
February | 9.17 | 15.63 | 3.67 | 15.92 | 0.00 | 15.92 | 0.00 | 15.92 |
March | 6.67 | 15.82 | 3.00 | 16.17 | 0.00 | 16.17 | 0.00 | 16.17 |
April | 3.67 | 16.10 | 2.33 | 16.34 | 0.00 | 16.34 | 0.00 | 16.34 |
May | 0.33 | 17.09 | 0.33 | 17.09 | 0.00 | 17.09 | 0.00 | 17.09 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 1.33 | 16.12 | 0.83 | 16.38 | 0.00 | 16.38 | 0.00 | 16.38 |
November | 2.67 | 16.42 | 2.33 | 16.52 | 0.00 | 16.52 | 0.00 | 16.52 |
December | 15.50 | 15.29 | 3.67 | 15.53 | 0.00 | 15.53 | 0.00 | 15.53 |
Annual Sum or Average | 43.33 | 15.73 | 19.17 | 16.03 | 0.00 | 16.03 | 0.00 | 16.03 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 15.50 | 17.09 | 3.67 | 17.09 | 0.00 | 17.09 | 0.00 | 17.09 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 63.50 | 14.63 | 3.33 | 14.63 | 0.00 | 14.63 | 0.00 | 14.63 |
February | 68.33 | 14.49 | 3.83 | 14.49 | 0.00 | 14.49 | 0.00 | 14.49 |
March | 52.00 | 14.65 | 4.00 | 14.65 | 0.00 | 14.65 | 0.00 | 14.65 |
April | 31.33 | 14.66 | 2.33 | 14.66 | 0.00 | 14.66 | 0.00 | 14.66 |
May | 1.67 | 14.89 | 0.33 | 14.88 | 0.00 | 14.88 | 0.00 | 14.88 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 8.50 | 27.48 | 0.00 | 27.48 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 12.83 | 27.46 | 0.00 | 27.46 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 27.42 | 0.00 | 27.42 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 3.33 | 27.38 | 0.00 | 27.38 |
October | 15.33 | 14.59 | 1.00 | 14.59 | 0.00 | 14.59 | 0.00 | 14.59 |
November | 33.67 | 14.62 | 2.33 | 14.62 | 0.00 | 14.62 | 0.00 | 14.62 |
December | 81.50 | 14.38 | 3.83 | 14.38 | 0.00 | 14.38 | 0.00 | 14.38 |
Annual Sum or Average | 347.33 | 14.55 | 21.00 | 14.55 | 30.33 | 15.53 | 0.00 | 15.53 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.38 | 0.00 | 14.38 |
Maximum of Months | 81.50 | 14.89 | 4.00 | 14.88 | 12.83 | 27.48 | 0.00 | 27.48 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 12.83 | 8.98 | 2.33 | 9.03 | 0.00 | 9.03 | 0.00 | 9.03 |
Annual Sum or Average | 12.83 | 8.98 | 2.33 | 9.03 | 0.00 | 9.03 | 0.00 | 9.03 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 12.83 | 8.98 | 2.33 | 9.03 | 0.00 | 9.03 | 0.00 | 9.03 |
Report: ComfortReportSimple55Monthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 300.00 | 20.84 | 283.50 | 20.78 | 283.50 | 20.77 |
February | 276.00 | 20.78 | 266.00 | 20.75 | 266.00 | 20.74 |
March | 324.00 | 21.19 | 256.33 | 20.97 | 256.33 | 20.89 |
April | 300.00 | 21.21 | 219.17 | 20.97 | 219.17 | 20.87 |
May | 301.00 | 22.83 | 54.83 | 22.47 | 54.83 | 22.20 |
June | 8.33 | 23.80 | 243.67 | 24.18 | 1.50 | 24.19 |
July | 22.33 | 24.43 | 285.50 | 24.23 | 22.33 | 24.25 |
August | 4.33 | 25.09 | 281.83 | 24.21 | 4.33 | 24.22 |
September | 78.33 | 23.37 | 114.33 | 23.83 | 1.33 | 23.80 |
October | 298.17 | 22.11 | 122.67 | 21.68 | 122.67 | 21.44 |
November | 288.00 | 21.08 | 238.00 | 20.91 | 238.00 | 20.84 |
December | 300.00 | 20.81 | 289.83 | 20.77 | 289.83 | 20.76 |
Annual Sum or Average | 2500.50 | 21.47 | 2655.67 | 21.70 | 1759.83 | 21.46 |
Minimum of Months | 4.33 | 20.78 | 54.83 | 20.75 | 1.33 | 20.74 |
Maximum of Months | 324.00 | 25.09 | 289.83 | 24.23 | 289.83 | 24.25 |
Report: ComfortReportSimple55Monthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 300.00 | 16.46 | 300.00 | 16.46 | 300.00 | 16.46 |
February | 276.00 | 16.31 | 276.00 | 16.31 | 276.00 | 16.31 |
March | 324.00 | 17.47 | 292.83 | 17.20 | 292.83 | 17.11 |
April | 300.00 | 17.75 | 269.50 | 17.54 | 269.50 | 17.47 |
May | 247.83 | 21.34 | 109.67 | 21.15 | 75.83 | 20.67 |
June | 140.67 | 26.49 | 297.17 | 26.50 | 133.17 | 26.54 |
July | 186.67 | 26.64 | 298.67 | 26.57 | 186.67 | 26.59 |
August | 170.33 | 26.66 | 318.67 | 26.54 | 170.33 | 26.57 |
September | 89.83 | 24.25 | 227.50 | 25.66 | 43.00 | 25.65 |
October | 283.17 | 19.59 | 168.83 | 18.93 | 162.67 | 18.55 |
November | 288.00 | 17.10 | 277.50 | 17.02 | 277.50 | 16.99 |
December | 300.00 | 16.21 | 300.00 | 16.21 | 300.00 | 16.21 |
Annual Sum or Average | 2906.50 | 19.43 | 3136.33 | 19.95 | 2487.50 | 19.65 |
Minimum of Months | 89.83 | 16.21 | 109.67 | 16.21 | 43.00 | 16.21 |
Maximum of Months | 324.00 | 26.66 | 318.67 | 26.57 | 300.00 | 26.59 |
Report: ComfortReportSimple55Monthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 300.00 | 11.46 | 300.00 | 11.46 | 300.00 | 11.46 |
February | 276.00 | 11.07 | 276.00 | 11.07 | 276.00 | 11.07 |
March | 324.00 | 12.40 | 324.00 | 12.40 | 324.00 | 12.40 |
April | 300.00 | 12.98 | 300.00 | 12.98 | 300.00 | 12.98 |
May | 312.00 | 18.75 | 214.67 | 18.22 | 214.67 | 17.99 |
June | 229.17 | 28.36 | 251.50 | 28.63 | 182.33 | 28.95 |
July | 287.33 | 29.64 | 300.00 | 29.57 | 287.33 | 29.59 |
August | 297.33 | 29.33 | 324.00 | 29.20 | 297.33 | 29.24 |
September | 176.50 | 26.43 | 193.00 | 27.01 | 108.50 | 27.37 |
October | 300.00 | 17.75 | 229.00 | 17.22 | 229.00 | 17.00 |
November | 288.00 | 12.22 | 288.00 | 12.22 | 288.00 | 12.22 |
December | 300.00 | 10.88 | 300.00 | 10.88 | 300.00 | 10.88 |
Annual Sum or Average | 3390.33 | 17.92 | 3300.17 | 17.99 | 3107.17 | 17.84 |
Minimum of Months | 176.50 | 10.88 | 193.00 | 10.88 | 108.50 | 10.88 |
Maximum of Months | 324.00 | 29.64 | 324.00 | 29.57 | 324.00 | 29.59 |
Report: OccupantComfortDataSummaryMonthly
For: OFFICE PEOPLE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: ZONE2 FINE STORAGEPEOPLE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: ZONE3 BULK STORAGEPEOPLE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 48139109.83 | 12034997.80 | 12.17 | 48139109.83 | -0.0 | 0.00 | 0.25 | 13-MAR-16:00 | 0.00 | 01-MAR-00:10 | 2200.62 | 13-MAR-16:00 | 2200.62 | 13-MAR-16:00 | 0.00 | 13-MAR-15:10 | 544.14 | 13-MAR-16:00 | 0.00 | 01-MAR-00:10 |
April | 376.82 | 96.82 | 0.67 | 376.82 | 0.00 | 0.00 | 0.00 | 20-APR-12:40 | 0.00 | 01-APR-00:10 | 0.24 | 20-APR-12:40 | 0.24 | 20-APR-12:40 | 0.00 | 20-APR-12:40 | 0.06 | 20-APR-12:40 | 0.00 | 01-APR-00:10 |
May | 0.924451E+09 | 0.229980E+09 | 99.58 | 0.916896E+09 | 7555410.41 | 0.00 | 0.67 | 31-MAY-16:00 | 0.00 | 01-MAY-00:10 | 6343.89 | 31-MAY-16:00 | 6114.65 | 31-MAY-16:00 | 250.93 | 30-MAY-16:00 | 1590.83 | 31-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.666048E+10 | 0.167187E+10 | 261.31 | 0.630136E+10 | 0.359121E+09 | 0.00 | 1.00 | 03-JUN-07:03 | 0.00 | 01-JUN-00:10 | 22122.68 | 21-JUN-07:03 | 20387.22 | 29-JUN-07:02 | 9508.57 | 17-JUN-07:02 | 4812.63 | 21-JUN-07:03 | 0.00 | 01-JUN-00:10 |
July | 0.686625E+10 | 0.169592E+10 | 252.23 | 0.633748E+10 | 0.528770E+09 | 0.00 | 1.00 | 01-JUL-06:03 | 0.00 | 01-JUL-00:10 | 22411.17 | 24-JUL-07:02 | 20466.62 | 15-JUL-07:02 | 9294.65 | 28-JUL-07:03 | 4888.63 | 24-JUL-07:02 | 0.00 | 01-JUL-00:10 |
August | 0.676128E+10 | 0.167664E+10 | 265.26 | 0.640024E+10 | 0.361046E+09 | 0.00 | 1.00 | 02-AUG-15:10 | 0.00 | 01-AUG-00:10 | 22969.92 | 04-AUG-07:02 | 20080.75 | 11-AUG-07:02 | 9098.33 | 04-AUG-07:02 | 4971.45 | 04-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.423007E+10 | 0.103077E+10 | 214.19 | 0.416685E+10 | 63218718.76 | 0.00 | 1.00 | 02-SEP-07:02 | 0.00 | 01-SEP-00:10 | 20162.65 | 13-SEP-07:02 | 19909.81 | 09-SEP-07:02 | 4908.52 | 02-SEP-07:02 | 4400.43 | 13-SEP-07:02 | 0.00 | 01-SEP-00:10 |
October | 0.300870E+09 | 73574242.43 | 38.00 | 0.300870E+09 | 0.00 | 0.00 | 0.63 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 | 5787.87 | 11-OCT-15:10 | 5787.87 | 11-OCT-15:10 | 0.00 | 11-OCT-15:00 | 1395.65 | 11-OCT-15:10 | 0.00 | 01-OCT-00:10 |
November | 1672040.49 | 427087.61 | 2.50 | 1672040.49 | 0.00 | 0.00 | 0.05 | 07-NOV-15:00 | 0.00 | 01-NOV-00:05 | 454.03 | 07-NOV-15:00 | 454.03 | 07-NOV-15:00 | 0.00 | 07-NOV-15:20 | 115.72 | 07-NOV-15:00 | 0.00 | 01-NOV-00:05 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.257932E+11 | 0.639122E+10 | 1145.92 | 0.244735E+11 | 0.131971E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.686625E+10 | 0.169592E+10 | 265.26 | 0.640024E+10 | 0.528770E+09 | 0.00 | 1.00 | 0.00 | 22969.92 | 20466.62 | 9508.57 | 4971.45 | 0.00 |
Report: DXReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
May | 19391531.30 | 5475059.37 | 5.17 | 19391531.30 | 0.00 | 0.00 | 0.09 | 31-MAY-15:50 | 0.00 | 01-MAY-00:10 | 2128.09 | 31-MAY-15:50 | 2128.09 | 31-MAY-15:50 | 0.00 | 31-MAY-15:50 | 593.39 | 31-MAY-15:50 | 0.00 | 01-MAY-00:10 |
June | 0.115367E+11 | 0.310443E+10 | 246.69 | 0.112726E+11 | 0.264099E+09 | 0.00 | 1.00 | 05-JUN-17:10 | 0.00 | 01-JUN-00:10 | 61440.68 | 18-JUN-10:05 | 55062.88 | 15-JUN-19:05 | 20496.09 | 18-JUN-09:15 | 14569.42 | 26-JUN-17:42 | 0.00 | 01-JUN-00:10 |
July | 0.123171E+11 | 0.328103E+10 | 265.19 | 0.120016E+11 | 0.315437E+09 | 0.00 | 1.00 | 01-JUL-17:06 | 0.00 | 01-JUL-00:10 | 63604.28 | 30-JUL-10:55 | 55309.01 | 26-JUL-17:11 | 25860.98 | 30-JUL-15:53 | 14349.80 | 16-JUL-12:43 | 0.00 | 01-JUL-00:10 |
August | 0.114166E+11 | 0.302038E+10 | 239.53 | 0.112106E+11 | 0.205998E+09 | 0.00 | 1.00 | 02-AUG-17:08 | 0.00 | 01-AUG-00:10 | 60010.84 | 05-AUG-17:23 | 55336.63 | 27-AUG-13:25 | 20488.67 | 05-AUG-17:23 | 14232.62 | 16-AUG-17:05 | 0.00 | 01-AUG-00:10 |
September | 0.443015E+10 | 0.117288E+10 | 140.65 | 0.441953E+10 | 10615044.09 | 0.00 | 1.00 | 02-SEP-17:10 | 0.00 | 01-SEP-00:10 | 55912.77 | 03-SEP-13:15 | 54810.09 | 03-SEP-14:11 | 2975.78 | 03-SEP-13:15 | 13672.60 | 10-SEP-12:53 | 0.00 | 01-SEP-00:10 |
October | 5897534.47 | 1619576.57 | 1.67 | 5897534.47 | 0.00 | 0.00 | 0.07 | 11-OCT-14:10 | 0.00 | 01-OCT-00:10 | 1520.48 | 11-OCT-14:10 | 1520.48 | 11-OCT-14:10 | 0.00 | 11-OCT-14:10 | 418.40 | 11-OCT-14:10 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 | 0.00 | 01-NOV-00:05 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.397259E+11 | 0.105858E+11 | 898.90 | 0.389297E+11 | 0.796149E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.123171E+11 | 0.328103E+10 | 265.19 | 0.120016E+11 | 0.315437E+09 | 0.00 | 1.00 | 0.00 | 63604.28 | 55336.63 | 25860.98 | 14569.42 | 0.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.82 | 74.62 | 43.20 | 121.91 | 128.83 | 0.00 | 0.00 | 0.00 |
February | 143.05 | 88.90 | 54.15 | 146.05 | 131.24 | 0.00 | 0.00 | 0.00 |
March | 166.75 | 92.07 | 74.68 | 179.81 | 97.17 | 0.00 | 0.00 | 0.00 |
April | 156.29 | 65.92 | 90.37 | 163.65 | 82.89 | 0.00 | 0.00 | 0.00 |
May | 191.60 | 67.52 | 124.09 | 227.24 | 57.08 | 0.00 | 0.00 | 0.00 |
June | 234.63 | 113.00 | 121.63 | 313.16 | 44.42 | 0.00 | 0.00 | 0.00 |
July | 190.84 | 69.80 | 121.04 | 254.01 | 42.13 | 0.00 | 0.00 | 0.00 |
August | 199.72 | 98.81 | 100.91 | 262.28 | 47.88 | 0.00 | 0.00 | 0.00 |
September | 177.31 | 85.22 | 92.09 | 224.44 | 66.54 | 0.00 | 0.00 | 0.00 |
October | 148.27 | 84.59 | 63.68 | 165.20 | 110.27 | 0.00 | 0.00 | 0.00 |
November | 121.85 | 73.91 | 47.94 | 128.72 | 118.65 | 0.00 | 0.00 | 0.00 |
December | 98.52 | 58.19 | 40.34 | 93.34 | 149.04 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 162.27 | 80.94 | 81.32 | 190.15 | 89.46 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 98.52 | 58.19 | 40.34 | 93.34 | 42.13 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 234.63 | 113.00 | 124.09 | 313.16 | 149.04 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.82 | 74.62 | 43.20 | 121.91 | 128.83 | 0.00 | 0.00 | 0.00 |
February | 143.05 | 88.90 | 54.15 | 146.05 | 131.24 | 0.00 | 0.00 | 0.00 |
March | 166.75 | 92.07 | 74.68 | 179.81 | 97.17 | 0.00 | 0.00 | 0.00 |
April | 156.29 | 65.92 | 90.37 | 163.65 | 82.89 | 0.00 | 0.00 | 0.00 |
May | 191.60 | 67.52 | 124.09 | 227.24 | 57.08 | 0.00 | 0.00 | 0.00 |
June | 234.63 | 113.00 | 121.63 | 313.16 | 44.42 | 0.00 | 0.00 | 0.00 |
July | 190.84 | 69.80 | 121.04 | 254.01 | 42.13 | 0.00 | 0.00 | 0.00 |
August | 199.72 | 98.81 | 100.91 | 262.28 | 47.88 | 0.00 | 0.00 | 0.00 |
September | 177.31 | 85.22 | 92.09 | 224.44 | 66.54 | 0.00 | 0.00 | 0.00 |
October | 148.27 | 84.59 | 63.68 | 165.20 | 110.27 | 0.00 | 0.00 | 0.00 |
November | 121.85 | 73.91 | 47.94 | 128.72 | 118.65 | 0.00 | 0.00 | 0.00 |
December | 98.52 | 58.19 | 40.34 | 93.34 | 149.04 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 162.27 | 80.94 | 81.32 | 190.15 | 89.46 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 98.52 | 58.19 | 40.34 | 93.34 | 42.13 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 234.63 | 113.00 | 124.09 | 313.16 | 149.04 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 20.66 | 0.00 | 20.66 | 6.53 | 79.40 | 0.00 | 0.00 | 0.00 |
February | 25.96 | 0.00 | 25.96 | 8.22 | 80.41 | 0.00 | 0.00 | 0.00 |
March | 35.34 | 0.00 | 35.34 | 21.27 | 58.97 | 0.00 | 0.00 | 0.00 |
April | 44.39 | 0.27 | 44.11 | 31.11 | 48.73 | 0.00 | 0.00 | 0.00 |
May | 60.67 | 2.04 | 58.63 | 60.54 | 31.69 | 0.00 | 0.00 | 0.00 |
June | 66.36 | 7.27 | 59.09 | 84.46 | 23.75 | 0.00 | 0.00 | 0.00 |
July | 62.98 | 4.17 | 58.80 | 80.72 | 23.07 | 0.00 | 0.00 | 0.00 |
August | 50.24 | 1.37 | 48.86 | 60.73 | 27.27 | 0.00 | 0.00 | 0.00 |
September | 42.06 | 0.03 | 42.03 | 45.36 | 38.95 | 0.00 | 0.00 | 0.00 |
October | 30.10 | 0.00 | 30.10 | 18.32 | 65.94 | 0.00 | 0.00 | 0.00 |
November | 22.85 | 0.00 | 22.85 | 9.59 | 72.10 | 0.00 | 0.00 | 0.00 |
December | 19.33 | 0.00 | 19.33 | 5.27 | 92.67 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 40.15 | 1.27 | 38.88 | 36.17 | 53.44 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 19.33 | 0.00 | 19.33 | 5.27 | 23.07 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 66.36 | 7.27 | 59.09 | 84.46 | 92.67 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 20.66 | 0.00 | 20.66 | 6.53 | 79.40 | 0.00 | 0.00 | 0.00 |
February | 25.96 | 0.00 | 25.96 | 8.22 | 80.41 | 0.00 | 0.00 | 0.00 |
March | 35.34 | 0.00 | 35.33 | 21.27 | 58.97 | 0.00 | 0.00 | 0.00 |
April | 44.38 | 0.27 | 44.11 | 31.11 | 48.73 | 0.00 | 0.00 | 0.00 |
May | 60.66 | 2.04 | 58.63 | 60.54 | 31.69 | 0.00 | 0.00 | 0.00 |
June | 66.36 | 7.27 | 59.09 | 84.46 | 23.75 | 0.00 | 0.00 | 0.00 |
July | 62.98 | 4.17 | 58.80 | 80.71 | 23.07 | 0.00 | 0.00 | 0.00 |
August | 50.23 | 1.37 | 48.86 | 60.73 | 27.27 | 0.00 | 0.00 | 0.00 |
September | 42.06 | 0.03 | 42.03 | 45.36 | 38.95 | 0.00 | 0.00 | 0.00 |
October | 30.10 | 0.00 | 30.10 | 18.32 | 65.94 | 0.00 | 0.00 | 0.00 |
November | 22.85 | 0.00 | 22.85 | 9.59 | 72.10 | 0.00 | 0.00 | 0.00 |
December | 19.33 | 0.00 | 19.33 | 5.27 | 92.67 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 40.15 | 1.27 | 38.88 | 36.16 | 53.44 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 19.33 | 0.00 | 19.33 | 5.27 | 23.07 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 66.36 | 7.27 | 59.09 | 84.46 | 92.67 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 59.38 | 65.13 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 90.31 | 65.90 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 123.94 | 49.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 134.34 | 41.46 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 182.43 | 31.30 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.15 | 28.34 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 207.99 | 26.50 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 206.69 | 30.17 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.23 | 39.87 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 102.58 | 55.63 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 72.09 | 58.63 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 45.72 | 75.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 135.44 | 47.28 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 45.72 | 26.50 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.15 | 75.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_6
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 59.38 | 65.13 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 90.31 | 65.90 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 123.94 | 49.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 134.34 | 41.46 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 182.43 | 31.30 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.15 | 28.34 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 207.99 | 26.50 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 206.69 | 30.17 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.23 | 39.87 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 102.58 | 55.63 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 72.09 | 58.63 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 45.72 | 75.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 135.44 | 47.28 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 45.72 | 26.50 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.15 | 75.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_7
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 59.38 | 65.13 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 90.31 | 65.90 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 123.94 | 49.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 134.34 | 41.46 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 182.43 | 31.30 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.15 | 28.34 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 207.99 | 26.50 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 206.69 | 30.17 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.23 | 39.87 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 102.58 | 55.63 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 72.09 | 58.63 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 45.72 | 75.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 135.44 | 47.28 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 45.72 | 26.50 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.15 | 75.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_8
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 59.38 | 65.13 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 90.31 | 65.90 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 123.94 | 49.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 134.34 | 41.46 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 182.43 | 31.30 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.15 | 28.34 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 207.99 | 26.50 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 206.69 | 30.17 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.23 | 39.87 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 102.58 | 55.63 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 72.09 | 58.63 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 45.72 | 75.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 135.44 | 47.28 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 45.72 | 26.50 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.15 | 75.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_9
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 59.38 | 65.13 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 90.31 | 65.90 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 123.94 | 49.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 134.34 | 41.46 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 182.43 | 31.30 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.15 | 28.34 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 207.99 | 26.50 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 206.69 | 30.17 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.23 | 39.87 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 102.58 | 55.63 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 72.09 | 58.63 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 45.72 | 75.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 135.44 | 47.28 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 45.72 | 26.50 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.15 | 75.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_10
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 59.38 | 65.13 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 90.31 | 65.90 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 123.94 | 49.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 134.34 | 41.46 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 182.43 | 31.30 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.15 | 28.34 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 207.99 | 26.50 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 206.69 | 30.17 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.23 | 39.87 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 102.58 | 55.63 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 72.09 | 58.63 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 45.72 | 75.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 135.44 | 47.28 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 45.72 | 26.50 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.15 | 75.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_5
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 59.38 | 65.13 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 90.31 | 65.90 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 123.94 | 49.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 134.34 | 41.46 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 182.43 | 31.30 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.15 | 28.34 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 207.99 | 26.50 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 206.69 | 30.17 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.23 | 39.87 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 102.58 | 55.63 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 72.09 | 58.63 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 45.72 | 75.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 135.44 | 47.28 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 45.72 | 26.50 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.15 | 75.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 59.38 | 65.13 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 90.31 | 65.90 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 123.94 | 49.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 134.34 | 41.46 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 182.43 | 31.30 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.15 | 28.34 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 207.99 | 26.50 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 206.69 | 30.17 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.23 | 39.87 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 102.58 | 55.63 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 72.09 | 58.63 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 45.72 | 75.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 135.44 | 47.28 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 45.72 | 26.50 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.15 | 75.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 59.38 | 65.13 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 90.31 | 65.90 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 123.94 | 49.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 134.34 | 41.46 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 182.43 | 31.30 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.15 | 28.34 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 207.99 | 26.50 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 206.69 | 30.17 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.23 | 39.87 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 102.58 | 55.63 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 72.09 | 58.63 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 45.72 | 75.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 135.44 | 47.28 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 45.72 | 26.50 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.15 | 75.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 59.38 | 65.13 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 90.31 | 65.90 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 123.94 | 49.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 134.34 | 41.46 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 182.43 | 31.30 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.15 | 28.34 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 207.99 | 26.50 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 206.69 | 30.17 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.23 | 39.87 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 102.58 | 55.63 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 72.09 | 58.63 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 45.72 | 75.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 135.44 | 47.28 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 45.72 | 26.50 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.15 | 75.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_14
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 59.38 | 65.13 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 90.31 | 65.90 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 123.94 | 49.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 134.34 | 41.46 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 182.43 | 31.30 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.15 | 28.34 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 207.99 | 26.50 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 206.69 | 30.17 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.23 | 39.87 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 102.58 | 55.63 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 72.09 | 58.63 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 45.72 | 75.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 135.44 | 47.28 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 45.72 | 26.50 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.15 | 75.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_13
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 59.38 | 65.13 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 90.31 | 65.90 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 123.94 | 49.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 134.34 | 41.46 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 182.43 | 31.30 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.15 | 28.34 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 207.99 | 26.50 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 206.69 | 30.17 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.23 | 39.87 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 102.58 | 55.63 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 72.09 | 58.63 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 45.72 | 75.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 135.44 | 47.28 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 45.72 | 26.50 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.15 | 75.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_12
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 59.38 | 65.13 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 90.31 | 65.90 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 123.94 | 49.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 134.34 | 41.46 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 182.43 | 31.30 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.15 | 28.34 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 207.99 | 26.50 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 206.69 | 30.17 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.23 | 39.87 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 102.58 | 55.63 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 72.09 | 58.63 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 45.72 | 75.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 135.44 | 47.28 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 45.72 | 26.50 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.15 | 75.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_11
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 59.38 | 65.13 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 90.31 | 65.90 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 123.94 | 49.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 134.34 | 41.46 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 182.43 | 31.30 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.15 | 28.34 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 207.99 | 26.50 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 206.69 | 30.17 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.23 | 39.87 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 102.58 | 55.63 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 72.09 | 58.63 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 45.72 | 75.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 135.44 | 47.28 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 45.72 | 26.50 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.15 | 75.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R8C1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R8C2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R8C4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R3C4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R3C2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R3C3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R3C1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R4C4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R4C3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R4C2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R4C1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R5C4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R5C1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R5C3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R5C2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R6C1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R6C2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R8C3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R6C4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R7C1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R7C2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R7C4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R6C3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R7C3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 58.41 | 41.54 | 16.86 | 65.89 | 50.09 | 0.00 | 0.00 | 0.00 |
February | 85.81 | 65.94 | 19.87 | 97.94 | 50.50 | 0.00 | 0.00 | 0.00 |
March | 111.48 | 78.12 | 33.36 | 132.92 | 36.93 | 0.00 | 0.00 | 0.00 |
April | 120.52 | 70.55 | 49.97 | 144.06 | 30.13 | 0.00 | 0.00 | 0.00 |
May | 153.85 | 82.03 | 71.82 | 190.66 | 25.18 | 0.00 | 0.00 | 0.00 |
June | 192.57 | 134.42 | 58.16 | 240.06 | 29.37 | 0.00 | 0.00 | 0.00 |
July | 166.91 | 99.43 | 67.49 | 203.29 | 31.67 | 0.00 | 0.00 | 0.00 |
August | 166.14 | 118.70 | 47.44 | 203.43 | 34.70 | 0.00 | 0.00 | 0.00 |
September | 130.51 | 87.46 | 43.04 | 157.25 | 41.44 | 0.00 | 0.00 | 0.00 |
October | 93.15 | 65.92 | 27.23 | 105.82 | 50.12 | 0.00 | 0.00 | 0.00 |
November | 67.24 | 48.49 | 18.75 | 78.56 | 44.60 | 0.00 | 0.00 | 0.00 |
December | 49.24 | 32.48 | 16.76 | 52.09 | 58.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 116.44 | 77.09 | 39.35 | 139.50 | 40.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.24 | 32.48 | 16.76 | 52.09 | 25.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 192.57 | 134.42 | 71.82 | 240.06 | 58.76 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.315572E+09 | 0.199870E+09 | 0.115702E+09 | 0.326520E+09 | 0.345058E+09 |
February | 0.346078E+09 | 0.215077E+09 | 0.131001E+09 | 0.353322E+09 | 0.317492E+09 |
March | 0.446621E+09 | 0.246599E+09 | 0.200022E+09 | 0.481603E+09 | 0.260248E+09 |
April | 0.405093E+09 | 0.170862E+09 | 0.234231E+09 | 0.424172E+09 | 0.214846E+09 |
May | 0.513184E+09 | 0.180832E+09 | 0.332352E+09 | 0.608647E+09 | 0.152890E+09 |
June | 0.608152E+09 | 0.292898E+09 | 0.315253E+09 | 0.811707E+09 | 0.115143E+09 |
July | 0.511144E+09 | 0.186954E+09 | 0.324190E+09 | 0.680340E+09 | 0.112847E+09 |
August | 0.534929E+09 | 0.264664E+09 | 0.270265E+09 | 0.702497E+09 | 0.128250E+09 |
September | 0.459600E+09 | 0.220901E+09 | 0.238699E+09 | 0.581759E+09 | 0.172463E+09 |
October | 0.397121E+09 | 0.226573E+09 | 0.170549E+09 | 0.442483E+09 | 0.295344E+09 |
November | 0.315827E+09 | 0.191572E+09 | 0.124255E+09 | 0.333640E+09 | 0.307548E+09 |
December | 0.263881E+09 | 0.155844E+09 | 0.108037E+09 | 0.250012E+09 | 0.399196E+09 |
Annual Sum or Average | 0.511720E+10 | 0.255265E+10 | 0.256456E+10 | 0.599670E+10 | 0.282133E+10 |
Minimum of Months | 0.263881E+09 | 0.155844E+09 | 0.108037E+09 | 0.250012E+09 | 0.112847E+09 |
Maximum of Months | 0.608152E+09 | 0.292898E+09 | 0.332352E+09 | 0.811707E+09 | 0.399196E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.315572E+09 | 0.199870E+09 | 0.115702E+09 | 0.326520E+09 | 0.345058E+09 |
February | 0.346078E+09 | 0.215077E+09 | 0.131001E+09 | 0.353322E+09 | 0.317492E+09 |
March | 0.446621E+09 | 0.246599E+09 | 0.200022E+09 | 0.481603E+09 | 0.260248E+09 |
April | 0.405093E+09 | 0.170862E+09 | 0.234231E+09 | 0.424172E+09 | 0.214846E+09 |
May | 0.513184E+09 | 0.180832E+09 | 0.332352E+09 | 0.608647E+09 | 0.152890E+09 |
June | 0.608152E+09 | 0.292898E+09 | 0.315253E+09 | 0.811707E+09 | 0.115143E+09 |
July | 0.511144E+09 | 0.186954E+09 | 0.324190E+09 | 0.680340E+09 | 0.112847E+09 |
August | 0.534929E+09 | 0.264664E+09 | 0.270265E+09 | 0.702497E+09 | 0.128250E+09 |
September | 0.459600E+09 | 0.220901E+09 | 0.238699E+09 | 0.581759E+09 | 0.172463E+09 |
October | 0.397121E+09 | 0.226573E+09 | 0.170549E+09 | 0.442483E+09 | 0.295344E+09 |
November | 0.315827E+09 | 0.191572E+09 | 0.124255E+09 | 0.333640E+09 | 0.307548E+09 |
December | 0.263881E+09 | 0.155844E+09 | 0.108037E+09 | 0.250012E+09 | 0.399196E+09 |
Annual Sum or Average | 0.511720E+10 | 0.255265E+10 | 0.256456E+10 | 0.599670E+10 | 0.282133E+10 |
Minimum of Months | 0.263881E+09 | 0.155844E+09 | 0.108037E+09 | 0.250012E+09 | 0.112847E+09 |
Maximum of Months | 0.608152E+09 | 0.292898E+09 | 0.332352E+09 | 0.811707E+09 | 0.399196E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 55325142.07 | 0.00 | 55325142.07 | 17490349.79 | 0.212675E+09 |
February | 62807707.53 | 0.00 | 62807707.53 | 19875991.01 | 0.194531E+09 |
March | 94653093.88 | 10335.88 | 94642758.00 | 56969543.49 | 0.157933E+09 |
April | 0.115049E+09 | 710289.13 | 0.114338E+09 | 80642978.10 | 0.126317E+09 |
May | 0.162487E+09 | 5452044.69 | 0.157035E+09 | 0.162158E+09 | 84875679.41 |
June | 0.172005E+09 | 18845768.36 | 0.153159E+09 | 0.218924E+09 | 61564319.85 |
July | 0.168680E+09 | 11182152.98 | 0.157498E+09 | 0.216190E+09 | 61790990.78 |
August | 0.134552E+09 | 3677816.15 | 0.130874E+09 | 0.162669E+09 | 73029081.28 |
September | 0.109011E+09 | 71736.72 | 0.108939E+09 | 0.117573E+09 | 0.100947E+09 |
October | 80610534.05 | 0.00 | 80610534.05 | 49071866.84 | 0.176616E+09 |
November | 59219626.80 | 0.00 | 59219626.80 | 24850108.72 | 0.186871E+09 |
December | 51763549.12 | 0.00 | 51763549.12 | 14113617.16 | 0.248212E+09 |
Annual Sum or Average | 0.126616E+10 | 39950143.90 | 0.122621E+10 | 0.114053E+10 | 0.168536E+10 |
Minimum of Months | 51763549.12 | 0.00 | 51763549.12 | 14113617.16 | 61564319.85 |
Maximum of Months | 0.172005E+09 | 18845768.36 | 0.157498E+09 | 0.218924E+09 | 0.248212E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 55323681.99 | 0.00 | 55323681.99 | 17489428.46 | 0.212675E+09 |
February | 62806159.31 | 0.00 | 62806159.31 | 19875064.00 | 0.194531E+09 |
March | 94650538.89 | 10335.39 | 94640203.50 | 56967366.04 | 0.157933E+09 |
April | 0.115045E+09 | 710255.83 | 0.114335E+09 | 80639614.96 | 0.126318E+09 |
May | 0.162482E+09 | 5451789.15 | 0.157030E+09 | 0.162152E+09 | 84875291.71 |
June | 0.172000E+09 | 18844885.03 | 0.153155E+09 | 0.218918E+09 | 61563736.25 |
July | 0.168675E+09 | 11181628.86 | 0.157494E+09 | 0.216184E+09 | 61790475.70 |
August | 0.134548E+09 | 3677643.77 | 0.130871E+09 | 0.162665E+09 | 73028521.37 |
September | 0.109008E+09 | 71733.36 | 0.108936E+09 | 0.117570E+09 | 0.100947E+09 |
October | 80608377.68 | 0.00 | 80608377.68 | 49070131.76 | 0.176616E+09 |
November | 59218068.30 | 0.00 | 59218068.30 | 24849015.43 | 0.186871E+09 |
December | 51762101.56 | 0.00 | 51762101.56 | 14112936.51 | 0.248211E+09 |
Annual Sum or Average | 0.126613E+10 | 39948271.39 | 0.122618E+10 | 0.114049E+10 | 0.168536E+10 |
Minimum of Months | 51762101.56 | 0.00 | 51762101.56 | 14112936.51 | 61563736.25 |
Maximum of Months | 0.172000E+09 | 18844885.03 | 0.157494E+09 | 0.218918E+09 | 0.248211E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.159040E+09 | 0.174446E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.218484E+09 | 0.159429E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.331954E+09 | 0.133722E+09 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.348209E+09 | 0.107457E+09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.488632E+09 | 83827829.99 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622478E+09 | 73452025.33 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.557076E+09 | 70979896.03 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.553588E+09 | 80796909.75 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407544E+09 | 0.103344E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.274763E+09 | 0.149008E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.186863E+09 | 0.151979E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 0.202430E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.427109E+10 | 0.149087E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 70979896.03 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622478E+09 | 0.202430E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_6
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.159040E+09 | 0.174446E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.218484E+09 | 0.159429E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.331954E+09 | 0.133722E+09 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.348209E+09 | 0.107457E+09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.488632E+09 | 83827829.99 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622478E+09 | 73452025.33 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.557076E+09 | 70979896.03 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.553588E+09 | 80796909.75 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407544E+09 | 0.103344E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.274763E+09 | 0.149008E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.186863E+09 | 0.151979E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 0.202430E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.427109E+10 | 0.149087E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 70979896.03 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622478E+09 | 0.202430E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_7
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.159040E+09 | 0.174446E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.218484E+09 | 0.159429E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.331954E+09 | 0.133722E+09 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.348209E+09 | 0.107457E+09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.488632E+09 | 83827829.99 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622478E+09 | 73452025.33 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.557076E+09 | 70979896.03 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.553588E+09 | 80796909.75 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407544E+09 | 0.103344E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.274763E+09 | 0.149008E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.186863E+09 | 0.151979E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 0.202430E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.427109E+10 | 0.149087E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 70979896.03 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622478E+09 | 0.202430E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_8
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.159040E+09 | 0.174446E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.218484E+09 | 0.159429E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.331954E+09 | 0.133722E+09 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.348209E+09 | 0.107457E+09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.488632E+09 | 83827829.99 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622478E+09 | 73452025.33 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.557076E+09 | 70979896.03 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.553588E+09 | 80796909.75 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407544E+09 | 0.103344E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.274763E+09 | 0.149008E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.186863E+09 | 0.151979E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 0.202430E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.427109E+10 | 0.149087E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 70979896.03 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622478E+09 | 0.202430E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_9
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.159040E+09 | 0.174446E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.218484E+09 | 0.159429E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.331954E+09 | 0.133722E+09 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.348209E+09 | 0.107457E+09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.488632E+09 | 83827829.99 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622478E+09 | 73452025.33 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.557076E+09 | 70979896.03 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.553588E+09 | 80796909.75 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407544E+09 | 0.103344E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.274763E+09 | 0.149008E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.186863E+09 | 0.151979E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 0.202430E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.427109E+10 | 0.149087E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 70979896.03 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622478E+09 | 0.202430E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_10
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.159040E+09 | 0.174446E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.218484E+09 | 0.159429E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.331954E+09 | 0.133722E+09 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.348209E+09 | 0.107457E+09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.488632E+09 | 83827829.99 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622478E+09 | 73452025.33 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.557076E+09 | 70979896.03 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.553588E+09 | 80796909.75 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407544E+09 | 0.103344E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.274763E+09 | 0.149008E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.186863E+09 | 0.151979E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 0.202430E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.427109E+10 | 0.149087E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 70979896.03 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622478E+09 | 0.202430E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_5
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.159040E+09 | 0.174446E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.218484E+09 | 0.159429E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.331954E+09 | 0.133722E+09 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.348209E+09 | 0.107457E+09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.488632E+09 | 83827829.99 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622478E+09 | 73452025.33 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.557076E+09 | 70979896.03 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.553588E+09 | 80796909.75 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407544E+09 | 0.103344E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.274763E+09 | 0.149008E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.186863E+09 | 0.151979E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 0.202430E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.427109E+10 | 0.149087E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 70979896.03 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622478E+09 | 0.202430E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.159040E+09 | 0.174446E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.218484E+09 | 0.159429E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.331954E+09 | 0.133722E+09 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.348209E+09 | 0.107457E+09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.488632E+09 | 83827829.99 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622478E+09 | 73452025.33 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.557076E+09 | 70979896.03 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.553588E+09 | 80796909.75 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407544E+09 | 0.103344E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.274763E+09 | 0.149008E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.186863E+09 | 0.151979E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 0.202430E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.427109E+10 | 0.149087E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 70979896.03 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622478E+09 | 0.202430E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.159040E+09 | 0.174446E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.218484E+09 | 0.159429E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.331954E+09 | 0.133722E+09 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.348209E+09 | 0.107457E+09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.488632E+09 | 83827829.99 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622478E+09 | 73452025.33 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.557076E+09 | 70979896.03 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.553588E+09 | 80796909.75 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407544E+09 | 0.103344E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.274763E+09 | 0.149008E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.186863E+09 | 0.151979E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 0.202430E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.427109E+10 | 0.149087E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 70979896.03 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622478E+09 | 0.202430E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.159040E+09 | 0.174446E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.218484E+09 | 0.159429E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.331954E+09 | 0.133722E+09 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.348209E+09 | 0.107457E+09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.488632E+09 | 83827829.99 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622478E+09 | 73452025.33 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.557076E+09 | 70979896.03 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.553588E+09 | 80796909.75 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407544E+09 | 0.103344E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.274763E+09 | 0.149008E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.186863E+09 | 0.151979E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 0.202430E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.427109E+10 | 0.149087E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 70979896.03 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622478E+09 | 0.202430E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_14
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.159040E+09 | 0.174446E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.218484E+09 | 0.159429E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.331954E+09 | 0.133722E+09 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.348209E+09 | 0.107457E+09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.488632E+09 | 83827829.99 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622478E+09 | 73452025.33 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.557076E+09 | 70979896.03 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.553588E+09 | 80796909.75 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407544E+09 | 0.103344E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.274763E+09 | 0.149008E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.186863E+09 | 0.151979E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 0.202430E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.427109E+10 | 0.149087E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 70979896.03 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622478E+09 | 0.202430E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_13
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.159040E+09 | 0.174446E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.218484E+09 | 0.159429E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.331954E+09 | 0.133722E+09 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.348209E+09 | 0.107457E+09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.488632E+09 | 83827829.99 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622478E+09 | 73452025.33 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.557076E+09 | 70979896.03 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.553588E+09 | 80796909.75 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407544E+09 | 0.103344E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.274763E+09 | 0.149008E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.186863E+09 | 0.151979E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 0.202430E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.427109E+10 | 0.149087E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 70979896.03 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622478E+09 | 0.202430E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_12
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.159040E+09 | 0.174446E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.218484E+09 | 0.159429E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.331954E+09 | 0.133722E+09 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.348209E+09 | 0.107457E+09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.488632E+09 | 83827829.99 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622478E+09 | 73452025.33 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.557076E+09 | 70979896.03 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.553588E+09 | 80796909.75 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407544E+09 | 0.103344E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.274763E+09 | 0.149008E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.186863E+09 | 0.151979E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 0.202430E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.427109E+10 | 0.149087E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 70979896.03 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622478E+09 | 0.202430E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_11
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.159040E+09 | 0.174446E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.218484E+09 | 0.159429E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.331954E+09 | 0.133722E+09 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.348209E+09 | 0.107457E+09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.488632E+09 | 83827829.99 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622478E+09 | 73452025.33 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.557076E+09 | 70979896.03 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.553588E+09 | 80796909.75 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407544E+09 | 0.103344E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.274763E+09 | 0.149008E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.186863E+09 | 0.151979E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 0.202430E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.427109E+10 | 0.149087E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.122461E+09 | 70979896.03 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622478E+09 | 0.202430E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R8C1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R8C2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R8C4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R3C4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R3C2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R3C3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R3C1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R4C4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R4C3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R4C2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R4C1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R5C4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R5C1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R5C3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R5C2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R6C1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R6C2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R8C3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R6C4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R7C1
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R7C2
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R7C4
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R6C3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R7C3
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.156434E+09 | 0.111266E+09 | 45167819.01 | 0.176475E+09 | 0.134174E+09 |
February | 0.207581E+09 | 0.159515E+09 | 48065452.24 | 0.236939E+09 | 0.122161E+09 |
March | 0.298597E+09 | 0.209236E+09 | 89360872.39 | 0.356014E+09 | 98910338.48 |
April | 0.312383E+09 | 0.182854E+09 | 0.129529E+09 | 0.373402E+09 | 78086806.09 |
May | 0.412060E+09 | 0.219705E+09 | 0.192355E+09 | 0.510656E+09 | 67435203.36 |
June | 0.499149E+09 | 0.348409E+09 | 0.150740E+09 | 0.622237E+09 | 76130828.47 |
July | 0.447063E+09 | 0.266301E+09 | 0.180762E+09 | 0.544488E+09 | 84817796.25 |
August | 0.444993E+09 | 0.317920E+09 | 0.127073E+09 | 0.544864E+09 | 92928977.82 |
September | 0.338272E+09 | 0.226703E+09 | 0.111569E+09 | 0.407598E+09 | 0.107410E+09 |
October | 0.249487E+09 | 0.176566E+09 | 72921071.46 | 0.283434E+09 | 0.134229E+09 |
November | 0.174287E+09 | 0.125692E+09 | 48595272.90 | 0.203622E+09 | 0.115598E+09 |
December | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 0.157372E+09 |
Annual Sum or Average | 0.367218E+10 | 0.243116E+10 | 0.124103E+10 | 0.439926E+10 | 0.126925E+10 |
Minimum of Months | 0.131878E+09 | 86989203.61 | 44888680.67 | 0.139531E+09 | 67435203.36 |
Maximum of Months | 0.499149E+09 | 0.348409E+09 | 0.192355E+09 | 0.622237E+09 | 0.157372E+09 |
Report: WindowZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 248.62 | 408.21 | 276.95 | 149.25 | 127.71 | 0.00 | 0.00 |
February | 300.15 | 414.92 | 338.03 | 177.81 | 160.23 | 0.00 | 0.00 |
March | 398.42 | 308.53 | 404.18 | 184.15 | 220.03 | 0.00 | 0.00 |
April | 388.03 | 261.76 | 401.34 | 132.39 | 268.96 | 0.00 | 0.00 |
May | 573.34 | 175.31 | 504.53 | 139.10 | 365.43 | 0.00 | 0.00 |
June | 791.14 | 132.25 | 601.97 | 240.54 | 361.43 | 0.00 | 0.00 |
July | 666.71 | 127.67 | 507.63 | 147.95 | 359.68 | 0.00 | 0.00 |
August | 645.12 | 149.39 | 499.91 | 200.37 | 299.53 | 0.00 | 0.00 |
September | 538.78 | 210.14 | 438.74 | 170.50 | 268.24 | 0.00 | 0.00 |
October | 364.63 | 350.00 | 356.73 | 169.19 | 187.54 | 0.00 | 0.00 |
November | 270.95 | 375.83 | 289.39 | 147.82 | 141.57 | 0.00 | 0.00 |
December | 188.17 | 474.38 | 235.70 | 116.37 | 119.32 | 0.00 | 0.00 |
Annual Sum or Average | 448.51 | 281.69 | 404.83 | 164.42 | 240.41 | 0.00 | 0.00 |
Minimum of Months | 188.17 | 127.67 | 235.70 | 116.37 | 119.32 | 0.00 | 0.00 |
Maximum of Months | 791.14 | 474.38 | 601.97 | 240.54 | 365.43 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 831.30 | 911.83 | 817.68 | 581.59 | 236.09 | 0.00 | 0.00 |
February | 1264.38 | 922.62 | 1201.28 | 923.12 | 278.16 | 0.00 | 0.00 |
March | 1735.12 | 698.97 | 1560.77 | 1093.68 | 467.09 | 0.00 | 0.00 |
April | 1880.76 | 580.40 | 1687.25 | 987.64 | 699.61 | 0.00 | 0.00 |
May | 2554.08 | 438.17 | 2153.84 | 1148.40 | 1005.44 | 0.00 | 0.00 |
June | 3362.15 | 396.73 | 2696.02 | 1881.84 | 814.18 | 0.00 | 0.00 |
July | 2911.83 | 371.01 | 2336.80 | 1391.96 | 944.84 | 0.00 | 0.00 |
August | 2893.61 | 422.33 | 2325.98 | 1661.77 | 664.21 | 0.00 | 0.00 |
September | 2201.24 | 558.18 | 1827.09 | 1224.47 | 602.61 | 0.00 | 0.00 |
October | 1436.19 | 778.87 | 1304.07 | 922.91 | 381.16 | 0.00 | 0.00 |
November | 1009.29 | 820.88 | 941.37 | 678.89 | 262.47 | 0.00 | 0.00 |
December | 640.10 | 1058.10 | 689.33 | 454.69 | 234.63 | 0.00 | 0.00 |
Annual Sum or Average | 1896.10 | 661.85 | 1630.22 | 1079.28 | 550.94 | 0.00 | 0.00 |
Minimum of Months | 640.10 | 371.01 | 689.33 | 454.69 | 234.63 | 0.00 | 0.00 |
Maximum of Months | 3362.15 | 1058.10 | 2696.02 | 1881.84 | 1005.44 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 8699.96 | 9890.52 | 1868.98 | 1329.34 | 539.64 | 0.00 | 0.00 |
February | 13297.43 | 11235.97 | 2745.78 | 2109.99 | 635.79 | 0.00 | 0.00 |
March | 17967.59 | 6759.32 | 3567.47 | 2499.84 | 1067.63 | 0.00 | 0.00 |
April | 20209.57 | 4741.00 | 3856.58 | 2257.46 | 1599.12 | 0.00 | 0.00 |
May | 25701.03 | 2575.10 | 4923.05 | 2624.91 | 2298.15 | 0.00 | 0.00 |
June | 36259.84 | 3031.66 | 6162.33 | 4301.34 | 1860.99 | 0.00 | 0.00 |
July | 33165.77 | 3259.55 | 5341.26 | 3181.62 | 2159.64 | 0.00 | 0.00 |
August | 30804.42 | 3525.39 | 5316.52 | 3798.33 | 1518.19 | 0.00 | 0.00 |
September | 20857.11 | 4136.12 | 4176.20 | 2798.80 | 1377.40 | 0.00 | 0.00 |
October | 14377.60 | 6284.28 | 2980.73 | 2109.51 | 871.22 | 0.00 | 0.00 |
November | 10169.82 | 7726.05 | 2151.70 | 1551.75 | 599.94 | 0.00 | 0.00 |
December | 7026.20 | 13952.20 | 1575.60 | 1039.30 | 536.30 | 0.00 | 0.00 |
Annual Sum or Average | 19910.24 | 6403.53 | 3726.21 | 2466.93 | 1259.29 | 0.00 | 0.00 |
Minimum of Months | 7026.20 | 2575.10 | 1575.60 | 1039.30 | 536.30 | 0.00 | 0.00 |
Maximum of Months | 36259.84 | 13952.20 | 6162.33 | 4301.34 | 2298.15 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.665915E+09 | 0.109336E+10 | 0.741793E+09 | 0.399740E+09 | 0.342053E+09 | 0.00 | 0.00 |
February | 0.726132E+09 | 0.100378E+10 | 0.817770E+09 | 0.430154E+09 | 0.387616E+09 | 0.00 | 0.00 |
March | 0.106713E+10 | 0.826354E+09 | 0.108255E+10 | 0.493219E+09 | 0.589326E+09 | 0.00 | 0.00 |
April | 0.100578E+10 | 0.678484E+09 | 0.104028E+10 | 0.343145E+09 | 0.697136E+09 | 0.00 | 0.00 |
May | 0.153563E+10 | 0.469553E+09 | 0.135134E+10 | 0.372568E+09 | 0.978769E+09 | 0.00 | 0.00 |
June | 0.205065E+10 | 0.342805E+09 | 0.156031E+10 | 0.623487E+09 | 0.936821E+09 | 0.00 | 0.00 |
July | 0.178573E+10 | 0.341948E+09 | 0.135964E+10 | 0.396272E+09 | 0.963372E+09 | 0.00 | 0.00 |
August | 0.172790E+10 | 0.400128E+09 | 0.133896E+10 | 0.536683E+09 | 0.802275E+09 | 0.00 | 0.00 |
September | 0.139652E+10 | 0.544678E+09 | 0.113722E+10 | 0.441945E+09 | 0.695273E+09 | 0.00 | 0.00 |
October | 0.976629E+09 | 0.937440E+09 | 0.955462E+09 | 0.453146E+09 | 0.502316E+09 | 0.00 | 0.00 |
November | 0.702297E+09 | 0.974157E+09 | 0.750092E+09 | 0.383143E+09 | 0.366948E+09 | 0.00 | 0.00 |
December | 0.504003E+09 | 0.127057E+10 | 0.631288E+09 | 0.311688E+09 | 0.319600E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.141443E+11 | 0.888326E+10 | 0.127667E+11 | 0.518519E+10 | 0.758151E+10 | 0.00 | 0.00 |
Minimum of Months | 0.504003E+09 | 0.341948E+09 | 0.631288E+09 | 0.311688E+09 | 0.319600E+09 | 0.00 | 0.00 |
Maximum of Months | 0.205065E+10 | 0.127057E+10 | 0.156031E+10 | 0.623487E+09 | 0.978769E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.222657E+10 | 0.244225E+10 | 0.219007E+10 | 0.155772E+10 | 0.632349E+09 | 0.00 | 0.00 |
February | 0.305878E+10 | 0.223201E+10 | 0.290613E+10 | 0.223321E+10 | 0.672916E+09 | 0.00 | 0.00 |
March | 0.464735E+10 | 0.187211E+10 | 0.418036E+10 | 0.292931E+10 | 0.125105E+10 | 0.00 | 0.00 |
April | 0.487493E+10 | 0.150440E+10 | 0.437336E+10 | 0.255996E+10 | 0.181340E+10 | 0.00 | 0.00 |
May | 0.684084E+10 | 0.117359E+10 | 0.576883E+10 | 0.307587E+10 | 0.269297E+10 | 0.00 | 0.00 |
June | 0.871469E+10 | 0.102833E+10 | 0.698808E+10 | 0.487772E+10 | 0.211036E+10 | 0.00 | 0.00 |
July | 0.779906E+10 | 0.993719E+09 | 0.625888E+10 | 0.372822E+10 | 0.253066E+10 | 0.00 | 0.00 |
August | 0.775024E+10 | 0.113116E+10 | 0.622990E+10 | 0.445088E+10 | 0.177902E+10 | 0.00 | 0.00 |
September | 0.570561E+10 | 0.144681E+10 | 0.473581E+10 | 0.317384E+10 | 0.156197E+10 | 0.00 | 0.00 |
October | 0.384669E+10 | 0.208612E+10 | 0.349282E+10 | 0.247193E+10 | 0.102090E+10 | 0.00 | 0.00 |
November | 0.261609E+10 | 0.212771E+10 | 0.244002E+10 | 0.175969E+10 | 0.680334E+09 | 0.00 | 0.00 |
December | 0.171445E+10 | 0.283402E+10 | 0.184629E+10 | 0.121785E+10 | 0.628442E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.597953E+11 | 0.208722E+11 | 0.514106E+11 | 0.340362E+11 | 0.173744E+11 | 0.00 | 0.00 |
Minimum of Months | 0.171445E+10 | 0.993719E+09 | 0.184629E+10 | 0.121785E+10 | 0.628442E+09 | 0.00 | 0.00 |
Maximum of Months | 0.871469E+10 | 0.283402E+10 | 0.698808E+10 | 0.487772E+10 | 0.269297E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.233020E+11 | 0.264908E+11 | 0.500588E+10 | 0.356051E+10 | 0.144537E+10 | 0.00 | 0.00 |
February | 0.321692E+11 | 0.271821E+11 | 0.664258E+10 | 0.510449E+10 | 0.153809E+10 | 0.00 | 0.00 |
March | 0.481244E+11 | 0.181042E+11 | 0.955511E+10 | 0.669556E+10 | 0.285955E+10 | 0.00 | 0.00 |
April | 0.523832E+11 | 0.122887E+11 | 0.999624E+10 | 0.585133E+10 | 0.414492E+10 | 0.00 | 0.00 |
May | 0.688376E+11 | 0.689714E+10 | 0.131859E+11 | 0.703056E+10 | 0.615535E+10 | 0.00 | 0.00 |
June | 0.939855E+11 | 0.785806E+10 | 0.159728E+11 | 0.111491E+11 | 0.482368E+10 | 0.00 | 0.00 |
July | 0.888312E+11 | 0.873037E+10 | 0.143060E+11 | 0.852164E+10 | 0.578438E+10 | 0.00 | 0.00 |
August | 0.825066E+11 | 0.944239E+10 | 0.142398E+11 | 0.101734E+11 | 0.406633E+10 | 0.00 | 0.00 |
September | 0.540616E+11 | 0.107208E+11 | 0.108247E+11 | 0.725449E+10 | 0.357021E+10 | 0.00 | 0.00 |
October | 0.385090E+11 | 0.168318E+11 | 0.798359E+10 | 0.565012E+10 | 0.233347E+10 | 0.00 | 0.00 |
November | 0.263602E+11 | 0.200259E+11 | 0.557719E+10 | 0.402215E+10 | 0.155505E+10 | 0.00 | 0.00 |
December | 0.188190E+11 | 0.373696E+11 | 0.422009E+10 | 0.278365E+10 | 0.143644E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.627889E+12 | 0.201942E+12 | 0.117510E+12 | 0.777970E+11 | 0.397128E+11 | 0.00 | 0.00 |
Minimum of Months | 0.188190E+11 | 0.689714E+10 | 0.422009E+10 | 0.278365E+10 | 0.143644E+10 | 0.00 | 0.00 |
Maximum of Months | 0.939855E+11 | 0.373696E+11 | 0.159728E+11 | 0.111491E+11 | 0.615535E+10 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 0.85 | -1.5 | -4.5 | 2.30 | -12.1 | 27.63 | 226.20 | 0.01 |
February | -0.2 | -2.7 | -6.1 | 3.74 | -13.6 | 32.55 | 253.27 | 0.01 |
March | 4.82 | 0.36 | -5.5 | 4.48 | -7.8 | 54.65 | 233.06 | 0.03 |
April | 6.08 | 2.29 | -2.0 | 5.23 | -4.9 | 81.86 | 179.11 | 0.05 |
May | 13.74 | 7.52 | 1.82 | 4.10 | 2.75 | 117.64 | 180.87 | 0.01 |
June | 22.16 | 12.46 | 5.10 | 4.19 | 9.76 | 95.26 | 290.95 | 0.00 |
July | 22.71 | 13.25 | 6.43 | 4.25 | 12.01 | 110.54 | 215.12 | 0.03 |
August | 21.74 | 12.79 | 6.20 | 3.81 | 10.76 | 77.72 | 272.61 | 0.02 |
September | 18.54 | 9.35 | 1.35 | 4.13 | 5.52 | 70.51 | 233.03 | 0.01 |
October | 7.12 | 2.51 | -2.7 | 3.54 | -5.8 | 44.60 | 216.74 | 0.01 |
November | 3.03 | 0.31 | -2.9 | 2.79 | -8.8 | 30.71 | 220.86 | 0.01 |
December | -1.0 | -4.5 | -9.5 | 4.43 | -15.4 | 27.45 | 194.75 | 0.01 |
Annual Sum or Average | 10.02 | 4.37 | -1.0 | 3.91 | -2.2 | 64.46 | 226.11 | 0.02 |
Minimum of Months | -1.0 | -4.5 | -9.5 | 2.30 | -15.4 | 27.45 | 179.11 | 0.00 |
Maximum of Months | 22.71 | 13.25 | 6.43 | 5.23 | 12.01 | 117.64 | 290.95 | 0.05 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 21.00 | 20-JAN-12:00 | 6.97 | -11.0 | 0.50 | 6.55 | 41.00 | 961.00 |
February | 20.00 | 18-FEB-12:00 | 7.74 | -5.0 | 3.60 | 6.35 | 56.00 | 998.00 |
March | 24.00 | 14-MAR-12:00 | 7.90 | -12.0 | 3.10 | 11.65 | 160.00 | 837.50 |
April | 22.00 | 19-APR-13:09 | 8.49 | -5.7 | 5.52 | 11.55 | 235.67 | 789.67 |
May | 29.00 | 17-MAY-12:00 | 11.92 | -3.0 | 5.10 | 18.99 | 432.50 | 162.00 |
June | 39.40 | 26-JUN-14:00 | 15.63 | -2.8 | 4.60 | 21.96 | 136.50 | 752.00 |
July | 37.00 | 16-JUL-12:00 | 14.90 | -3.0 | 3.10 | 26.65 | 319.50 | 109.50 |
August | 37.00 | 16-AUG-13:00 | 16.36 | 3.00 | 3.60 | 28.27 | 90.00 | 895.00 |
September | 32.70 | 09-SEP-12:00 | 13.05 | -3.9 | 3.00 | 16.30 | 270.50 | 562.00 |
October | 27.00 | 11-OCT-13:00 | 9.73 | -9.0 | 4.60 | 12.03 | 89.50 | 844.00 |
November | 22.00 | 06-NOV-13:09 | 7.10 | -13.0 | 2.60 | 4.92 | 88.67 | 883.33 |
December | 22.00 | 01-DEC-13:00 | 7.94 | -8.0 | 2.60 | 5.13 | 49.00 | 862.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 20.00 | 6.97 | -13.0 | 0.50 | 4.92 | 41.00 | 109.50 | |
Maximum of Months | 39.40 | 16.36 | 3.00 | 5.52 | 28.27 | 432.50 | 998.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -19.0 | 05-JAN-18:00 | -19.0 | -19.0 | 1.50 | -37.1 | 0.00 | 0.00 |
February | -20.0 | 12-FEB-04:00 | -20.0 | -20.0 | 3.60 | -39.1 | 0.00 | 0.00 |
March | -15.6 | 19-MAR-06:00 | -15.6 | -15.6 | 10.80 | -25.3 | 24.00 | 0.00 |
April | -8.0 | 03-APR-02:00 | -8.0 | -8.0 | 3.10 | -22.2 | 0.00 | 0.00 |
May | -1.0 | 03-MAY-01:00 | -2.4 | -4.0 | 4.10 | -15.7 | 0.00 | 0.00 |
June | 6.60 | 09-JUN-03:00 | 3.45 | 0.00 | 3.60 | -6.9 | 0.00 | 0.00 |
July | 9.00 | 02-JUL-04:00 | 3.30 | -3.0 | 3.60 | -5.3 | 20.00 | 184.50 |
August | 11.00 | 12-AUG-22:00 | 7.22 | 4.00 | 4.10 | 5.13 | 0.00 | 0.00 |
September | -1.7 | 22-SEP-05:10 | -2.9 | -4.3 | 3.60 | -15.8 | 0.00 | 0.00 |
October | -10.0 | 30-OCT-03:00 | -10.0 | -10.0 | 2.60 | -18.6 | 0.00 | 0.00 |
November | -15.0 | 29-NOV-20:00 | -15.0 | -15.0 | 3.10 | -33.5 | 0.00 | 0.00 |
December | -23.0 | 22-DEC-02:00 | -23.0 | -23.0 | 3.60 | -42.7 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -23.0 | -23.0 | -23.0 | 1.50 | -42.7 | 0.00 | 0.00 | |
Maximum of Months | 11.00 | 7.22 | 4.00 | 10.80 | 5.13 | 24.00 | 184.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 7.55 | 20-JAN-11:00 | 20.00 | -6.0 | 2.60 | 7.95 | 43.00 | 971.50 |
February | 7.98 | 18-FEB-14:00 | 19.00 | -3.0 | 3.60 | 5.94 | 151.00 | 410.00 |
March | 8.00 | 31-MAR-17:00 | 15.00 | 2.00 | 2.60 | 1.58 | 19.50 | 261.00 |
April | 12.50 | 28-APR-13:00 | 18.00 | 9.00 | 9.80 | 9.72 | 335.00 | 196.50 |
May | 14.87 | 31-MAY-13:00 | 28.00 | 7.00 | 4.60 | 14.47 | 157.50 | 830.50 |
June | 19.65 | 18-JUN-11:00 | 29.40 | 15.50 | 6.10 | 16.85 | 272.50 | 596.00 |
July | 19.75 | 30-JUL-13:00 | 29.00 | 16.00 | 3.60 | 18.99 | 217.50 | 412.00 |
August | 18.80 | 05-AUG-14:09 | 25.83 | 15.33 | 6.62 | 20.54 | 196.33 | 4.00 |
September | 14.95 | 01-SEP-11:00 | 24.40 | 9.40 | 3.00 | 10.69 | 193.50 | 684.00 |
October | 9.73 | 11-OCT-13:00 | 27.00 | -9.0 | 4.60 | 12.03 | 89.50 | 844.00 |
November | 9.33 | 09-NOV-10:00 | 20.00 | 0.00 | 1.50 | 11.07 | 112.00 | 860.50 |
December | 7.94 | 01-DEC-13:00 | 22.00 | -8.0 | 2.60 | 5.13 | 49.00 | 862.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 7.55 | 15.00 | -9.0 | 1.50 | 1.58 | 19.50 | 4.00 | |
Maximum of Months | 19.75 | 29.40 | 16.00 | 9.80 | 20.54 | 335.00 | 971.50 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 5.00 | 28-JAN-10:00 | 5.00 | 5.00 | 1.00 | -6.2 | 207.00 | 309.00 |
February | 5.00 | 19-FEB-14:30 | 5.00 | 5.00 | 1.80 | -0.4 | 188.00 | 467.00 |
March | 7.00 | 17-MAR-14:00 | 8.00 | 7.39 | 8.20 | 1.16 | 121.50 | 3.00 |
April | 9.00 | 28-APR-13:00 | 18.00 | 12.50 | 9.80 | 9.72 | 335.00 | 196.50 |
May | 11.00 | 21-MAY-21:10 | 12.83 | 11.73 | 2.68 | 6.78 | 0.00 | 0.00 |
June | 15.50 | 18-JUN-11:00 | 29.40 | 19.65 | 6.10 | 16.85 | 272.50 | 596.00 |
July | 17.00 | 28-JUL-16:00 | 20.00 | 17.92 | 5.70 | 15.02 | 155.00 | 32.00 |
August | 18.00 | 04-AUG-01:00 | 18.00 | 18.00 | 2.60 | 8.74 | 0.00 | 0.00 |
September | 12.20 | 30-SEP-14:00 | 17.20 | 13.90 | 5.10 | 9.72 | 209.00 | 82.50 |
October | 6.00 | 01-OCT-19:00 | 9.00 | 7.28 | 3.10 | 3.69 | 0.00 | 0.00 |
November | 7.00 | 09-NOV-23:00 | 8.00 | 7.40 | 4.10 | 3.06 | 0.00 | 0.00 |
December | 1.00 | 30-DEC-14:00 | 7.00 | 4.06 | 9.80 | -1.2 | 101.00 | 91.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 1.00 | 5.00 | 4.06 | 1.00 | -6.2 | 0.00 | 0.00 | |
Maximum of Months | 18.00 | 29.40 | 19.65 | 9.80 | 16.85 | 335.00 | 596.00 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 8.52 | 21.53 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 7.90 | 29.36 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 8.65 | 35.75 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 10.64 | 38.62 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 13.34 | 48.35 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 16.03 | 59.81 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 17.97 | 52.29 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 18.66 | 51.98 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 17.88 | 41.73 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 15.85 | 30.82 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 13.14 | 23.90 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 10.46 | 18.59 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 13.28 | 37.76 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 7.90 | 18.59 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 18.66 | 59.81 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.988839E+09 | -901542998.1 | 0.00 | 0.00 | 744.00 | 0.00 | -87295746.6 | 58.99 | 0.00 | 0.00 |
February | 0.917348E+09 | -838412388.7 | 0.00 | 0.00 | 672.00 | 0.00 | -78935836.6 | 58.98 | 0.00 | 0.00 |
March | 0.105088E+10 | -965415008.0 | 0.00 | 0.00 | 744.00 | 0.00 | -85464794.0 | 58.99 | 0.00 | 0.00 |
April | 0.944293E+09 | -861671616.7 | 0.00 | 0.00 | 720.00 | 0.00 | -82620889.8 | 58.99 | 0.00 | 0.00 |
May | 0.925114E+09 | -846612565.0 | 0.00 | 0.00 | 744.00 | 0.00 | -78500958.1 | 58.99 | 0.00 | 0.00 |
June | 0.862703E+09 | -793581151.7 | 0.00 | 0.00 | 720.00 | 0.00 | -69121372.5 | 59.00 | 0.00 | 0.00 |
July | 0.802909E+09 | -732125894.5 | 0.00 | 0.00 | 744.00 | 0.00 | -70783602.5 | 59.00 | 0.00 | 0.00 |
August | 0.844773E+09 | -773651899.1 | 0.00 | 0.00 | 744.00 | 0.00 | -71120934.0 | 58.99 | 0.00 | 0.00 |
September | 0.803580E+09 | -733231791.9 | 0.00 | 0.00 | 720.00 | 0.00 | -70348617.9 | 58.99 | 0.00 | 0.00 |
October | 0.851948E+09 | -771067588.1 | 0.00 | 0.00 | 744.00 | 0.00 | -80880643.1 | 59.00 | 0.00 | 0.00 |
November | 0.869593E+09 | -786511744.0 | 0.00 | 0.00 | 720.00 | 0.00 | -83080821.0 | 58.99 | 0.00 | 0.00 |
December | 0.953483E+09 | -866015060.0 | 0.00 | 0.00 | 744.00 | 0.00 | -87468399.1 | 59.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.108155E+11 | -0.986984E+10 | 0.00 | 0.00 | 8760.00 | 0.00 | -945622615.2 | 58.99 | 0.00 | 0.00 |
Minimum of Months | 0.802909E+09 | -965415008.0 | 0.00 | 0.00 | 672.00 | 0.00 | -87468399.1 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.105088E+10 | -732125894.5 | 0.00 | 0.00 | 744.00 | 0.00 | -69121372.5 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: ZONE2 FINE STORAGE_DAYLCTRL
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.50 | 0.88 | 0.50 | 27-JAN-11:30 | 134.21 | 0.00 | 0.00 | 15.50 | 113.60 | 0.00 | 0.00 | 2.50 |
February | 245.50 | 0.86 | 0.50 | 01-FEB-11:20 | 159.12 | 0.00 | 0.00 | 18.00 | 135.64 | 0.00 | 0.00 | 8.67 |
March | 296.17 | 0.77 | 0.50 | 01-MAR-11:20 | 230.58 | 0.00 | 0.00 | 70.50 | 1496.51 | 0.00 | 0.00 | 68.83 |
April | 296.67 | 0.71 | 0.50 | 03-APR-10:39 | 312.29 | 0.00 | 0.00 | 145.00 | 246.52 | 0.00 | 0.00 | 94.00 |
May | 415.33 | 0.68 | 0.50 | 01-MAY-08:30 | 375.91 | 0.00 | 0.00 | 237.17 | 848.65 | 0.00 | 0.00 | 179.33 |
June | 421.50 | 0.71 | 0.50 | 01-JUN-09:00 | 323.22 | 0.00 | 0.00 | 206.17 | 2883.11 | 0.00 | 0.00 | 143.83 |
July | 430.33 | 0.70 | 0.50 | 02-JUL-09:39 | 359.49 | 0.00 | 0.00 | 225.67 | 1656.28 | 0.00 | 0.00 | 172.67 |
August | 394.50 | 0.72 | 0.50 | 01-AUG-09:50 | 286.67 | 0.00 | 0.00 | 149.67 | 231.79 | 0.00 | 0.00 | 98.83 |
September | 354.00 | 0.75 | 0.50 | 01-SEP-11:50 | 263.26 | 0.00 | 0.00 | 118.00 | 213.80 | 0.00 | 0.00 | 81.17 |
October | 262.67 | 0.79 | 0.50 | 01-OCT-11:50 | 206.31 | 0.00 | 0.00 | 41.33 | 174.10 | 0.00 | 0.00 | 22.67 |
November | 257.67 | 0.86 | 0.50 | 01-NOV-10:00 | 149.62 | 0.00 | 0.00 | 12.17 | 128.77 | 0.00 | 0.00 | 5.33 |
December | 251.17 | 0.88 | 0.58 | 06-DEC-10:30 | 133.39 | 0.00 | 0.00 | 1.00 | 113.33 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3902.00 | 0.76 | 260.56 | 0.00 | 0.00 | 1240.17 | 803.70 | 0.00 | 0.00 | 877.83 | ||
Minimum of Months | 245.50 | 0.68 | 0.50 | 133.39 | 0.00 | 0.00 | 1.00 | 113.33 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 430.33 | 0.88 | 0.58 | 375.91 | 0.00 | 0.00 | 237.17 | 2883.11 | 0.00 | 0.00 | 179.33 |
Report: DaylightingReportMonthly
For: ZONE3 BULK STORAGE_DAYLCTRL
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.50 | 0.77 | 0.50 | 02-JAN-10:20 | 158.01 | 10.44 | 0.00 | 68.33 | 749.96 | 14.05 | 7.17 | 58.83 |
February | 245.50 | 0.71 | 0.50 | 01-FEB-10:39 | 188.36 | 11.74 | 0.00 | 80.17 | 578.17 | 15.62 | 16.33 | 52.67 |
March | 296.17 | 0.64 | 0.50 | 01-MAR-10:39 | 1076.38 | 15.66 | 28.67 | 223.33 | 1969.60 | 17.06 | 52.17 | 168.83 |
April | 296.67 | 0.60 | 0.50 | 03-APR-09:39 | 357.86 | 14.80 | 2.67 | 264.00 | 301.88 | 18.59 | 88.83 | 230.17 |
May | 415.33 | 0.60 | 0.50 | 01-MAY-07:40 | 2409.87 | 16.85 | 61.33 | 324.50 | 1007.80 | 19.76 | 136.33 | 296.67 |
June | 421.50 | 0.60 | 0.50 | 01-JUN-06:30 | 1802.74 | 15.18 | 23.50 | 310.50 | 3603.25 | 20.92 | 126.50 | 294.17 |
July | 430.33 | 0.60 | 0.50 | 01-JUL-08:30 | 3134.05 | 16.15 | 39.17 | 324.50 | 2397.89 | 18.76 | 130.67 | 292.17 |
August | 394.50 | 0.60 | 0.50 | 01-AUG-06:49 | 1080.50 | 14.36 | 2.33 | 295.83 | 2111.70 | 19.78 | 119.50 | 246.67 |
September | 354.00 | 0.63 | 0.50 | 01-SEP-08:39 | 303.58 | 13.86 | 0.00 | 242.17 | 561.17 | 19.06 | 92.83 | 220.17 |
October | 262.67 | 0.64 | 0.50 | 01-OCT-08:39 | 243.73 | 13.25 | 0.00 | 185.50 | 431.51 | 18.06 | 58.50 | 143.33 |
November | 257.67 | 0.72 | 0.50 | 01-NOV-08:00 | 177.98 | 11.49 | 0.00 | 78.67 | 395.66 | 16.97 | 32.00 | 71.67 |
December | 251.17 | 0.75 | 0.50 | 01-DEC-09:50 | 158.75 | 11.10 | 0.00 | 68.33 | 249.30 | 15.63 | 14.17 | 55.50 |
Annual Sum or Average | 3902.00 | 0.65 | 1104.00 | 14.08 | 157.67 | 2465.83 | 1358.55 | 18.19 | 875.00 | 2130.83 | ||
Minimum of Months | 245.50 | 0.60 | 0.50 | 158.01 | 10.44 | 0.00 | 68.33 | 249.30 | 14.05 | 7.17 | 52.67 | |
Maximum of Months | 430.33 | 0.77 | 0.50 | 3134.05 | 16.85 | 61.33 | 324.50 | 3603.25 | 20.92 | 136.33 | 296.67 |
Report: DaylightingReportMonthly
For: ZONE1 OFFICE_DAYLCTRL
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.50 | 0.90 | 0.80 | 16-JAN-15:30 | 452.17 | 23.66 | 121.00 | 50.67 | 115.08 | 19.95 | 73.67 | 0.17 |
February | 245.50 | 0.89 | 0.80 | 01-FEB-15:09 | 870.33 | 25.52 | 110.17 | 63.83 | 250.23 | 23.53 | 107.33 | 22.00 |
March | 296.17 | 0.87 | 0.80 | 01-MAR-14:20 | 521.24 | 24.63 | 157.33 | 96.17 | 435.26 | 25.06 | 171.50 | 57.00 |
April | 296.67 | 0.86 | 0.80 | 04-APR-13:50 | 451.14 | 22.73 | 165.33 | 93.00 | 507.23 | 24.85 | 208.17 | 61.67 |
May | 415.33 | 0.86 | 0.80 | 01-MAY-14:09 | 349.76 | 21.75 | 243.33 | 158.00 | 277.40 | 22.83 | 293.67 | 107.67 |
June | 421.50 | 0.86 | 0.80 | 01-JUN-13:50 | 342.94 | 21.82 | 231.83 | 146.50 | 382.68 | 23.11 | 315.83 | 109.50 |
July | 430.33 | 0.86 | 0.80 | 01-JUL-15:09 | 340.40 | 21.71 | 243.67 | 150.17 | 313.36 | 22.88 | 307.00 | 96.17 |
August | 394.50 | 0.86 | 0.80 | 01-AUG-14:50 | 311.46 | 21.72 | 205.00 | 102.33 | 329.11 | 23.10 | 277.00 | 75.67 |
September | 354.00 | 0.87 | 0.80 | 01-SEP-13:20 | 340.37 | 22.88 | 196.17 | 116.67 | 373.26 | 24.90 | 230.33 | 76.50 |
October | 262.67 | 0.87 | 0.80 | 01-OCT-13:50 | 609.27 | 24.81 | 146.17 | 75.17 | 202.39 | 22.97 | 176.50 | 25.00 |
November | 257.67 | 0.89 | 0.80 | 01-NOV-14:09 | 394.84 | 24.45 | 126.33 | 48.00 | 132.91 | 20.92 | 98.83 | 1.17 |
December | 251.17 | 0.90 | 0.81 | 09-DEC-14:30 | 317.39 | 23.82 | 118.00 | 37.67 | 116.41 | 20.43 | 67.67 | 0.00 |
Annual Sum or Average | 3902.00 | 0.87 | 422.36 | 23.04 | 2064.33 | 1138.17 | 297.95 | 22.97 | 2327.50 | 632.50 | ||
Minimum of Months | 245.50 | 0.86 | 0.80 | 311.46 | 21.71 | 110.17 | 37.67 | 115.08 | 19.95 | 67.67 | 0.00 | |
Maximum of Months | 430.33 | 0.90 | 0.81 | 870.33 | 25.52 | 243.67 | 158.00 | 507.23 | 25.06 | 315.83 | 109.50 |
Report: CoilReportMonthly
For: PSZ-OFFICE HEATING COIL
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.498908E+10 | 28247.79 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.539627E+10 | 28247.79 | 01-FEB-06:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.405682E+10 | 28247.79 | 01-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.266522E+10 | 28247.79 | 01-APR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.414684E+09 | 28247.79 | 01-MAY-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 28970435.70 | 12810.51 | 22-SEP-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.186519E+10 | 28247.79 | 17-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.363866E+10 | 28247.79 | 01-NOV-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.651288E+10 | 28247.79 | 01-DEC-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.295678E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.651288E+10 | 28247.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE HEATING COIL
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.144569E+11 | 87378.67 | 03-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.163466E+11 | 87378.67 | 02-FEB-05:23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.106519E+11 | 87378.67 | 02-MAR-04:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.656174E+10 | 87378.67 | 03-APR-03:32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.533125E+09 | 45580.55 | 02-MAY-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.441723E+10 | 87378.67 | 29-OCT-20:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.907760E+10 | 87378.67 | 01-NOV-00:22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.233083E+11 | 87378.67 | 07-DEC-21:23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.853533E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.233083E+11 | 87378.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.232594E+11 | 52180.41 | 08-JAN-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.380780E+11 | 82930.90 | 12-FEB-05:51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.182291E+11 | 93494.64 | 19-MAR-06:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.998552E+10 | 52721.13 | 16-APR-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.382644E+10 | 46744.32 | 31-OCT-24:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.128021E+11 | 79368.28 | 30-NOV-05:52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.626780E+11 | 93494.64 | 19-DEC-23:51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.168859E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.626780E+11 | 93494.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 48139109.83 | 48139109.83 | 2200.62 | 13-MAR-16:00 | 2200.62 | 0.00 |
April | 0.00 | 0.00 | 376.82 | 376.82 | 0.24 | 20-APR-12:40 | 0.24 | 0.00 |
May | 0.00 | 0.00 | 0.924451E+09 | 0.916896E+09 | 6343.89 | 31-MAY-16:00 | 6114.65 | 0.00 |
June | 0.00 | 0.00 | 0.666048E+10 | 0.630136E+10 | 22122.68 | 21-JUN-07:03 | 13823.11 | 0.00 |
July | 0.00 | 0.00 | 0.686625E+10 | 0.633748E+10 | 22411.17 | 24-JUL-07:02 | 17886.50 | 0.00 |
August | 0.00 | 0.00 | 0.676128E+10 | 0.640024E+10 | 22969.92 | 04-AUG-07:02 | 13871.59 | 0.00 |
September | 0.00 | 0.00 | 0.423007E+10 | 0.416685E+10 | 20162.65 | 13-SEP-07:02 | 18963.31 | 0.00 |
October | 0.00 | 0.00 | 0.300870E+09 | 0.300870E+09 | 5787.87 | 11-OCT-15:10 | 5787.87 | 0.00 |
November | 0.00 | 0.00 | 1672040.49 | 1672040.49 | 454.03 | 07-NOV-15:00 | 454.03 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.257932E+11 | 0.244735E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.686625E+10 | 0.640024E+10 | 22969.92 | 18963.31 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 19391531.30 | 19391531.30 | 2128.09 | 31-MAY-15:50 | 2128.09 | 0.00 |
June | 0.00 | 0.00 | 0.115367E+11 | 0.112726E+11 | 61440.68 | 18-JUN-10:05 | 44143.48 | 0.00 |
July | 0.00 | 0.00 | 0.123171E+11 | 0.120016E+11 | 63604.28 | 30-JUL-10:55 | 40042.64 | 0.00 |
August | 0.00 | 0.00 | 0.114166E+11 | 0.112106E+11 | 60010.84 | 05-AUG-17:23 | 39522.16 | 0.00 |
September | 0.00 | 0.00 | 0.443015E+10 | 0.441953E+10 | 55912.77 | 03-SEP-13:15 | 52936.99 | 0.00 |
October | 0.00 | 0.00 | 5897534.47 | 5897534.47 | 1520.48 | 11-OCT-14:10 | 1520.48 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:05 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.397259E+11 | 0.389297E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.123171E+11 | 0.120016E+11 | 63604.28 | 52936.99 | 0.00 |
Report: FanReportMonthly
For: ZONE3UNITHEATER ZONE3HIRADIANT FAN
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.297139E+09 | 0.04 | 261.46 | 01-JAN-00:05 | 0.09 |
February | 0.355835E+09 | 0.05 | 261.46 | 01-FEB-00:03 | 0.09 |
March | 0.244286E+09 | 0.03 | 261.46 | 01-MAR-03:00 | 0.09 |
April | 0.126549E+09 | 0.02 | 261.46 | 01-APR-19:20 | 0.09 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 |
October | 49259889.73 | 0.01 | 261.46 | 29-OCT-12:30 | 0.09 |
November | 0.144731E+09 | 0.02 | 261.46 | 01-NOV-00:05 | 0.09 |
December | 0.451337E+09 | 0.06 | 261.46 | 01-DEC-00:03 | 0.09 |
Annual Sum or Average | 0.166914E+10 | 0.02 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.451337E+09 | 0.06 | 261.46 | 0.09 |
Report: FanReportMonthly
For: PSZ-OFFICE_ADDAQ SUPPLY FAN
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.738202E+09 | 0.37 | 1447.58 | 02-JAN-06:01 | 1.12 |
February | 0.710367E+09 | 0.43 | 1447.58 | 01-FEB-06:11 | 1.12 |
March | 0.754391E+09 | 0.37 | 1447.58 | 01-MAR-06:01 | 1.12 |
April | 0.662143E+09 | 0.33 | 1447.58 | 01-APR-06:02 | 1.12 |
May | 0.609543E+09 | 0.27 | 1447.58 | 01-MAY-05:01 | 1.12 |
June | 0.621583E+09 | 0.28 | 1447.58 | 06-JUN-07:02 | 1.11 |
July | 0.586270E+09 | 0.25 | 1447.58 | 01-JUL-07:02 | 1.12 |
August | 0.636648E+09 | 0.27 | 1447.58 | 03-AUG-07:02 | 1.11 |
September | 0.575197E+09 | 0.26 | 1447.58 | 02-SEP-07:02 | 1.11 |
October | 0.633725E+09 | 0.29 | 1447.58 | 17-OCT-06:02 | 1.12 |
November | 0.667999E+09 | 0.31 | 1447.58 | 01-NOV-05:01 | 1.12 |
December | 0.796063E+09 | 0.44 | 1447.58 | 01-DEC-06:02 | 1.12 |
Annual Sum or Average | 0.799213E+10 | 0.32 | |||
Minimum of Months | 0.575197E+09 | 0.25 | 1447.58 | 1.11 | |
Maximum of Months | 0.796063E+09 | 0.44 | 1447.58 | 1.12 |
Report: FanReportMonthly
For: PSZ-FINE STORAGE_ADDAQ SUPPLY FAN
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.178214E+10 | 0.59 | 3272.34 | 03-JAN-06:01 | 1.08 |
February | 0.174287E+10 | 0.62 | 3272.34 | 02-FEB-05:23 | 1.08 |
March | 0.175946E+10 | 0.51 | 3272.34 | 02-MAR-04:03 | 1.08 |
April | 0.152359E+10 | 0.44 | 3272.34 | 03-APR-03:32 | 1.08 |
May | 0.136686E+10 | 0.27 | 2333.13 | 02-MAY-06:02 | 0.92 |
June | 0.145915E+10 | 0.30 | 3272.34 | 15-JUN-17:06 | 1.08 |
July | 0.143225E+10 | 0.29 | 3272.34 | 01-JUL-17:06 | 1.08 |
August | 0.148361E+10 | 0.29 | 3272.34 | 06-AUG-12:13 | 1.07 |
September | 0.132921E+10 | 0.26 | 3272.34 | 10-SEP-12:53 | 1.08 |
October | 0.143708E+10 | 0.34 | 3272.34 | 29-OCT-20:03 | 1.08 |
November | 0.154494E+10 | 0.48 | 3272.34 | 01-NOV-00:22 | 1.08 |
December | 0.206083E+10 | 0.66 | 3272.34 | 07-DEC-21:23 | 1.09 |
Annual Sum or Average | 0.189220E+11 | 0.42 | |||
Minimum of Months | 0.132921E+10 | 0.26 | 2333.13 | 0.92 | |
Maximum of Months | 0.206083E+10 | 0.66 | 3272.34 | 1.09 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-OFFICE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.738202E+09 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.710367E+09 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.766426E+09 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.662143E+09 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.839523E+09 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.229345E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.228219E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.231329E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.160597E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.707299E+09 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.668427E+09 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.796063E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.143834E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.662143E+09 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.231329E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.178214E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.174287E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.175946E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.152359E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.137234E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.456358E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.471328E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.450399E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.250210E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.143870E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.154494E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.206083E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.295078E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.137234E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.471328E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-OFFICE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.738202E+09 | 0.00 | 0.498908E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.710367E+09 | 0.00 | 0.539627E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.754391E+09 | 48139109.83 | 0.405682E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.662143E+09 | 376.82 | 0.266522E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.609543E+09 | 0.924451E+09 | 0.414684E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.621583E+09 | 0.666048E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.586270E+09 | 0.686625E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.636648E+09 | 0.676128E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.575197E+09 | 0.423007E+10 | 28970435.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.633725E+09 | 0.300870E+09 | 0.186519E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.667999E+09 | 1672040.49 | 0.363866E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.796063E+09 | 0.00 | 0.651288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.799213E+10 | 0.257932E+11 | 0.295678E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.575197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.796063E+09 | 0.686625E+10 | 0.651288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-FINE STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.178214E+10 | 0.00 | 0.144569E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.174287E+10 | 0.00 | 0.163466E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.175946E+10 | 0.00 | 0.106519E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.152359E+10 | 0.00 | 0.656174E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.136686E+10 | 19391531.30 | 0.533125E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.145915E+10 | 0.112854E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.143225E+10 | 0.120397E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.148361E+10 | 0.111432E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.132921E+10 | 0.431026E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.143708E+10 | 5897534.47 | 0.441723E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.154494E+10 | 0.00 | 0.907760E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.206083E+10 | 0.00 | 0.233083E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.189220E+11 | 0.388039E+11 | 0.853533E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.132921E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.206083E+10 | 0.120397E+11 | 0.233083E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-OFFICE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.738202E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.710367E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.754391E+09 | 0.00 | 0.00 | 0.00 | 12034997.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.662143E+09 | 0.00 | 0.00 | 0.00 | 96.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.609543E+09 | 0.00 | 0.00 | 0.00 | 0.229980E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.621583E+09 | 0.00 | 0.00 | 0.00 | 0.167187E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.586270E+09 | 0.00 | 0.00 | 0.00 | 0.169592E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.636648E+09 | 0.00 | 0.00 | 0.00 | 0.167664E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.575197E+09 | 0.00 | 0.00 | 0.00 | 0.103077E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.633725E+09 | 0.00 | 0.00 | 0.00 | 73574242.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.667999E+09 | 0.00 | 0.00 | 0.00 | 427087.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.796063E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.799213E+10 | 0.00 | 0.00 | 0.00 | 0.639122E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.575197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.796063E+09 | 0.00 | 0.00 | 0.00 | 0.169592E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.178214E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.174287E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.175946E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.152359E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.136686E+10 | 0.00 | 0.00 | 0.00 | 5475059.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.145915E+10 | 0.00 | 0.00 | 0.00 | 0.310443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.143225E+10 | 0.00 | 0.00 | 0.00 | 0.328103E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.148361E+10 | 0.00 | 0.00 | 0.00 | 0.302038E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.132921E+10 | 0.00 | 0.00 | 0.00 | 0.117288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.143708E+10 | 0.00 | 0.00 | 0.00 | 1619576.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.154494E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.206083E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.189220E+11 | 0.00 | 0.00 | 0.00 | 0.105858E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.132921E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.206083E+10 | 0.00 | 0.00 | 0.00 | 0.328103E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.179379E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156826E+10 | 0.00 | 0.00 | 0.12 |
February | 0.122297E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156437E+10 | 0.00 | 0.00 | 0.13 |
March | 0.301443E+09 | 0.00 | 0.00 | 166364.73 | 0.00 | 0.121883E+10 | 0.156230E+09 | 0.00 | 0.17 |
April | 0.399658E+09 | 0.00 | 0.00 | 38410.25 | 0.00 | 0.852006E+09 | 79900196.66 | 0.00 | 0.14 |
May | 0.269524E+09 | 4233197.51 | 0.00 | 1971249.29 | 0.00 | 0.111255E+09 | 0.112833E+10 | 0.00 | 0.33 |
June | 5221238.93 | 0.222987E+09 | 0.00 | 4321142.51 | 0.00 | 0.00 | 0.675874E+09 | 0.00 | 0.35 |
July | 2471764.60 | 0.274675E+09 | 0.00 | 4404451.10 | 0.00 | 0.00 | 0.423612E+09 | 0.00 | 0.31 |
August | 2657957.30 | 0.200581E+09 | 0.00 | 5726016.87 | 0.00 | 0.00 | 0.981845E+09 | 0.00 | 0.36 |
September | 61047719.49 | 34888834.54 | 0.00 | 5344400.72 | 0.00 | 7505299.35 | 0.124265E+10 | 0.00 | 0.42 |
October | 0.489053E+09 | 0.00 | 0.00 | 1165871.30 | 0.00 | 0.561190E+09 | 0.807450E+09 | 0.00 | 0.23 |
November | 0.345837E+09 | 0.00 | 0.00 | 41010.36 | 0.00 | 0.116206E+10 | 67109078.75 | 0.00 | 0.13 |
December | 0.135600E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180265E+10 | 0.00 | 0.00 | 0.12 |
Annual Sum or Average | 0.231419E+10 | 0.737365E+09 | 0.00 | 23178917.13 | 0.00 | 0.884813E+10 | 0.556301E+10 | 0.00 | 0.24 |
Minimum of Months | 2471764.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.12 |
Maximum of Months | 0.489053E+09 | 0.274675E+09 | 0.00 | 5726016.87 | 0.00 | 0.180265E+10 | 0.124265E+10 | 0.00 | 0.42 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.322268E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.186580E+10 | 0.00 | 0.00 | 0.17 |
February | 0.302788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192228E+10 | 0.00 | 0.00 | 0.18 |
March | 0.310939E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142291E+10 | 0.00 | 0.00 | 0.19 |
April | 0.300706E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.566845E+09 | 0.00 | 0.00 | 0.18 |
May | 0.288670E+10 | 0.00 | 0.00 | 9016.62 | 6614.72 | 18422599.01 | 32154527.51 | 0.00 | 0.18 |
June | 0.400457E+09 | 0.268867E+09 | 0.00 | 9678306.41 | 0.00 | 0.00 | 0.227563E+10 | 0.00 | 0.36 |
July | 0.226529E+09 | 0.220052E+09 | 0.00 | 11011605.96 | 0.00 | 0.00 | 0.208062E+10 | 0.00 | 0.34 |
August | 0.432147E+09 | 0.216875E+09 | 0.00 | 12906150.45 | 0.00 | 0.00 | 0.309506E+10 | 0.00 | 0.35 |
September | 0.125112E+10 | 6649933.56 | 0.00 | 6511892.06 | 955764.93 | 0.00 | 0.217695E+10 | 0.00 | 0.30 |
October | 0.360523E+10 | 0.00 | 0.00 | 1161.50 | 0.00 | 0.898862E+09 | 12752632.18 | 0.00 | 0.18 |
November | 0.327949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121587E+10 | 0.00 | 0.00 | 0.17 |
December | 0.220700E+10 | 0.00 | 0.00 | 0.00 | 781606.70 | 0.355028E+10 | 0.00 | 0.00 | 0.17 |
Annual Sum or Average | 0.266557E+11 | 0.712444E+09 | 0.00 | 40118133.01 | 1743986.35 | 0.114613E+11 | 0.967317E+10 | 0.00 | 0.23 |
Minimum of Months | 0.226529E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 |
Maximum of Months | 0.360523E+10 | 0.268867E+09 | 0.00 | 12906150.45 | 955764.93 | 0.355028E+10 | 0.309506E+10 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 10:43:46
Custom Monthly ReportSITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
January | 0.508232E+12 | 0.335428E+11 | 0.00 | 0.683612E+10 | 0.148524E+11 |
February | 0.657463E+12 | 0.538664E+11 | 0.00 | 0.663683E+10 | 0.194936E+11 |
March | 0.842040E+12 | 0.534980E+11 | 0.00 | 0.620897E+10 | 0.114972E+11 |
April | 0.873861E+12 | 0.464277E+11 | 0.00 | 0.490550E+10 | 0.683060E+10 |
May | 0.110130E+13 | 0.281996E+11 | 0.00 | 0.444413E+10 | 0.164599E+10 |
June | 0.121919E+13 | 0.227214E+11 | 0.00 | 0.287652E+10 | 0.229735E+11 |
July | 0.112627E+13 | 0.351386E+11 | 0.00 | 0.223977E+10 | 0.241603E+11 |
August | 0.112320E+13 | 0.353740E+11 | 0.00 | 0.412332E+10 | 0.228749E+11 |
September | 0.829285E+12 | 0.400856E+11 | 0.00 | 0.470948E+10 | 0.108783E+11 |
October | 0.667885E+12 | 0.546875E+11 | 0.00 | 0.637570E+10 | 0.424779E+10 |
November | 0.550275E+12 | 0.391114E+11 | 0.00 | 0.607041E+10 | 0.917212E+10 |
December | 0.386763E+12 | 0.769112E+11 | 0.00 | 0.769475E+10 | 0.289583E+11 |
Annual Sum or Average | 0.988576E+13 | 0.519564E+12 | 0.00 | 0.631215E+11 | 0.177585E+12 |
Minimum of Months | 0.386763E+12 | 0.227214E+11 | 0.00 | 0.223977E+10 | 0.164599E+10 |
Maximum of Months | 0.121919E+13 | 0.769112E+11 | 0.00 | 0.769475E+10 | 0.289583E+11 |