Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 10:43
Tabular Output Report in Format: HTML
Building: Warehouse
Environment: RUNPERIOD 1 ** Great Falls Intl Arpt MT USA TMY3 WMO#=727750
Simulation Timestamp: 2023-10-16 10:43:55
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1242.80 | 257.04 | 257.04 |
Net Site Energy | 1242.80 | 257.04 | 257.04 |
Total Source Energy | 2211.57 | 457.40 | 457.40 |
Net Source Energy | 2211.57 | 457.40 | 457.40 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 1.200 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil No 1 | 1.050 |
Fuel Oil No 2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4835.13 |
Net Conditioned Building Area | 4835.13 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 827.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 137.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 72.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 139.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 33.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 26.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 414.97 | 827.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 827.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 137.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 72.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 139.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 33.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 26.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Unassigned | 0.00 | 827.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | Unassigned | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GENERAL | 137.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | Unassigned | 72.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | GENERAL | 139.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Unassigned | 33.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Unassigned | 26.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 43.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 13.52 | 171.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 85.82 | 171.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 43.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 13.52 | 171.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 85.82 | 171.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 414.969 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 414.969 | 100.00 |
Total On-Site and Utility Electric Sources | 414.969 | 100.00 |
Total Electricity End Uses | 414.969 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 51.61 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 51.61 | 100.00 |
Total Water End Uses | 51.61 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 52.17 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 2987.50 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2018
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 6B
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MT_GREATFALLS
| Environment |ZoneCoolingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneHeatingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneElectricSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |PeakSpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainComponentsAtCoolingPeakMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ComfortReportSimple55Monthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |OccupantComfortDataSummaryMonthly
| OFFICE PEOPLE | ZONE2 FINE STORAGEPEOPLE | ZONE3 BULK STORAGEPEOPLE |DXReportMonthly
| PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |WindowReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C2 | SKYLIGHT_R1C3 | SKYLIGHT_R1C4 | SKYLIGHT_R1C5 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R2C5 |WindowEnergyReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C2 | SKYLIGHT_R1C3 | SKYLIGHT_R1C4 | SKYLIGHT_R1C5 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R2C5 |WindowZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |WindowEnergyZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWHSYS1 WATER HEATER |DaylightingReportMonthly
| ZONE3 BULK STORAGE_DAYLCTRL | ZONE1 OFFICE_DAYLCTRL |CoilReportMonthly
| PSZ-OFFICE HEATING COIL | PSZ-FINE STORAGE HEATING COIL | ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |FanReportMonthly
| ZONE3UNITHEATER ZONE3HIRADIANT FAN | PSZ-OFFICE_ADDAQ SUPPLY FAN | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN |ZoneTemperatureOscillationReportMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentLoadsMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentEnergyUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |MechanicalVentilationLoadsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
GeneralValue | |
Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 10:43 |
RunPeriod | RUNPERIOD 1 |
Weather File | Great Falls Intl Arpt MT USA TMY3 WMO#=727750 |
Latitude [deg] | 47.47 |
Longitude [deg] | -111.4 |
Elevation [m] | 1117.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 90.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | |
Gross Roof Area [m2] | 4598.25 |
Skylight Area [m2] | 14.86 |
Skylight-Roof Ratio [%] | 0.32 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
ZONE1 OFFICE | 236.88 | Yes | Yes | 1010.76 | 1.00 | 149.56 | 0.00 | 17.66 | 17.66 | 7.6766 | 18.58 | 8.0737 |
ZONE2 FINE STORAGE | 1393.41 | Yes | Yes | 2953.02 | 1.00 | 760.80 | 0.00 | 0.00 | 0.00 | 6.6844 | 46.45 | 0.0000 |
ZONE3 BULK STORAGE | 3204.84 | Yes | Yes | 35277.63 | 1.00 | 1586.63 | 0.00 | 0.00 | 0.00 | 3.3906 | 46.45 | 2.5587 |
Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 4.5498 | 43.27 | 2.0915 | |||
Conditioned Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 4.5498 | 43.27 | 2.0915 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
ZONE1 OFFICE | 236.88 | Yes | Yes | 1.00 | ZONE1 OFFICE | GENERAL | ZONE1 OFFICE | 7.6766 | 18.58 | 8.0737 | |
ZONE2 FINE STORAGE | 1393.41 | Yes | Yes | 1.00 | ZONE2 FINE STORAGE | GENERAL | ZONE2 FINE STORAGE | 6.6844 | 46.45 | 0.0000 | |
ZONE3 BULK STORAGE | 3204.84 | Yes | Yes | 1.00 | ZONE3 BULK STORAGE | GENERAL | ZONE3 BULK STORAGE | 3.3906 | 46.45 | 2.5587 | |
Total | 4835.13 | 4.5498 | 21.63 | 2.0915 | |||||||
Conditioned Total | 4835.13 | 4.5498 | 21.63 | 2.0915 | |||||||
Unconditioned Total | 0.00 | 0.0000 | 0.00 | 0.0000 | |||||||
Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
GENERAL | 4835.13 | 4835.13 | 0.00 | 0.00 | 4.5498 | 43.27 | 2.0915 |
Total | 4835.13 | 4835.13 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
End UsesElectricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 10-AUG-14:00 | 05-JAN-17:10 | - | - | - | - | - | - | - | - | - | - | 02-JAN-12:09 |
Heating | 0.00 | 271217.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 7310.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 9701.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 4400.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1766.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 33291.51 | 271217.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 271217.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 7310.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 9701.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 2094.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 1766.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 897.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 16.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 435.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 230.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 441.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 106.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 83.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1314.21 | 897.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 185.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 3.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 90.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 47.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 91.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 22.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 17.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 271.80 | 185.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 185.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 3.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 90.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 47.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 91.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 22.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 17.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 271.80 | 185.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
AirTerminal:SingleDuct:ConstantVolume:NoReheatDesign Size Maximum Air Flow Rate [m3/s] | |
ZONE1 OFFICE DIRECT AIR | 1.11 |
ZONE2 FINE STORAGE DIRECT AIR | 1.94 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
ZONE3 BULK STORAGE UNIT HEATER | 3.67 |
Design Size Maximum Flow Rate [m3/s] | |
ZONE3UNITHEATER ZONE3HIRADIANT FAN | 3.67 |
Design Size Nominal Capacity [W] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | 131493.17 |
PSZ-OFFICE HEATING COIL | 27439.48 |
PSZ-FINE STORAGE HEATING COIL | 69620.04 |
User-Specified Heating Design Capacity [W] | |
ZONE3 BULK STORAGE HIRADIANT | 131493.18 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-OFFICE | 1.11 | 1.11 | 1.11 | 1.11 | 1.11 | 1.11 | 1.00 | 1.00 | 1.11 |
PSZ-FINE STORAGE | 1.94 | 1.94 | 1.94 | 1.94 | 1.94 | 1.94 | 1.00 | 1.000000 | 1.94 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-OFFICE_OA_CONTROLLER | 1.11 | 0.102285 |
PSZ-FINE STORAGE_OA_CONTROLLER | 1.94 | 0.424711 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-OFFICE_ADDAQ SUPPLY FAN | 1.11 | 1224.17 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | 1.94 | 2077.41 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-OFFICE_UNITARY_PACKAGE_DX | 1.11 | 1.11 | 1.11 | 1.11 | 18303.08 | 27439.48 | 40.00 | 1.00 |
PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | 1.94 | 1.94 | 1.94 | 1.28 | 38249.26 | 69620.04 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | User-Specified Speed 2 Rated Sensible Heat Ratio | User-Specified Speed 1 Rated Sensible Heat Ratio | |
PSZ-OFFICE COOLING COIL | 1.11 | 0.552844 | 0.737127 | 18303.08 | 9151.54 | 0.800660 | 0.800660 |
PSZ-FINE STORAGE COOLING COIL | 1.94 | 0.970711 | 1.29 | 38249.26 | 19124.63 | 0.781910 | 0.781910 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
OFFICE FRONT WALL | OFFICE FRONT DOOR | OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | |
OFFICE LEFT WALL | OFFICE LEFT WALL DOOR | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | |
FINE STORAGE FRONT WALL | FINE STORAGE OVERHEAD DOOR1 | |
FINE STORAGE RIGHT WALL | FINE STORAGE OVERHEAD DOOR2 | FINE STORAGE OVERHEAD DOOR3 | FINE STORAGE RIGHT DOOR | |
FINE STORAGE LEFT WALL | FINE STORAGE OVERHEAD DOOR4 | FINE STORAGE LEFT DOOR | |
BULK STORAGE RIGHT WALL | BULK STORAGE OVERHEAD DOOR8 | BULK STORAGE OVERHEAD DOOR9 | BULK STORAGE OVERHEAD DOOR10 | BULK STORAGE OVERHEAD DOOR11 | BULK STORAGE DOOR1 | BULK STORAGE DOOR2 | BULK STORAGE DOOR3 | |
BULK STORAGE REAR WALL | BULK STORAGE OVERHEAD DOOR12 | BULK STORAGE OVERHEAD DOOR13 | BULK STORAGE OVERHEAD DOOR14 | BULK STORAGE OVERHEAD DOOR15 | BULK STORAGE DOOR4 | |
BULK STORAGE LEFT WALL | BULK STORAGE OVERHEAD DOOR1 | BULK STORAGE OVERHEAD DOOR2 | BULK STORAGE OVERHEAD DOOR3 | BULK STORAGE OVERHEAD DOOR4 | BULK STORAGE OVERHEAD DOOR5 | BULK STORAGE OVERHEAD DOOR6 | BULK STORAGE OVERHEAD DOOR7 | BULK STORAGE DOOR5 | |
BULK STORAGE ROOF | SKYLIGHT_R1C1 | SKYLIGHT_R1C2 | SKYLIGHT_R1C3 | SKYLIGHT_R1C4 | SKYLIGHT_R1C5 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R2C5 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
VersionVersion ID | |
1 | 22.1 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 8.60 | 2.80 | -4.10 | -8.80 | -2.20 | 0.30 | 6.70 | 10.10 | 16.50 | 20.60 | 19.20 | 14.70 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Great Falls Intl Arpt MT USA TMY3 WMO#=727750 | 47.47 | -111.38 | -7.00 | 1117.00 | 88606 | 1.0531 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 7.03 | 29.40 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | Warehouse | 90.000 | Urban | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.220 | 370.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 3 | 66 | 42 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | ZONE1 OFFICE | 0.0 | 0.00 | 0.00 | 0.00 | 4.57 | -12.95 | 2.13 | 1 | 1 | 1 | 0.00 | 9.14 | -25.91 | 5.60E-016 | 0.00 | 4.27 | 4.27 | 1010.76 | TARP | TARP | 236.88 | 149.56 | 128.00 | 17.66 | 6 | 6 | 0 | Yes |
2 | ZONE2 FINE STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 14.29 | -22.82 | 4.51 | 1 | 1 | 1 | 0.00 | 30.48 | -45.72 | 1.87E-015 | 0.00 | 8.53 | 7.81 | 2953.02 | TARP | TARP | 1393.41 | 760.80 | 727.17 | 0.00 | 11 | 6 | 0 | Yes |
3 | ZONE3 BULK STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 65.53 | -22.86 | 4.27 | 1 | 1 | 1 | 30.48 | 100.58 | -45.72 | 6.16E-015 | 0.00 | 8.53 | 8.53 | 35277.63 | TARP | TARP | 3204.84 | 1586.63 | 1471.35 | 14.86 | 6 | 30 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | ZONE1 OFFICE | 236.88 | 12.7 | 18.581 | 5.382E-002 | 7.677 | 8.074 | 0.000 | 0.000 | 0.000 | 0.000 | 15.750 | No |
2 | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 46.447 | 2.153E-002 | 6.684 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.684 | No |
3 | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 46.447 | 2.153E-002 | 3.391 | 2.559 | 0.000 | 0.000 | 0.000 | 0.000 | 5.949 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
1 | OFFICE PEOPLE | BLDG_OCC_SCH | ZONE1 OFFICE | 236.88 | 12.7 | 12.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | OFFICE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 13 |
2 | ZONE2 FINE STORAGEPEOPLE | BLDG_OCC_SCH | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 30.0 | 2.153E-002 | 46.447 | 0.300 | 0.700 | AutoCalculate | ZONE2 FINE STORAGE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 30 |
3 | ZONE3 BULK STORAGEPEOPLE | BLDG_OCC_SCH | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 69.0 | 2.153E-002 | 46.447 | 0.300 | 0.700 | AutoCalculate | ZONE3 BULK STORAGE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 69 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | OFFICE LIGHTS | LTG_SCH_OFFICE | ZONE1 OFFICE | 236.88 | 12.7 | 1818.427 | 7.677 | 142.636 | 0.000 | 0.370 | 0.180 | 0.450 | 1.000 | LightsWired | 0.000 | 1818.427 |
2 | FINE STORAGE AREA LIGHTS | LTG_SCH_FINE_STORAGE | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 9314.081 | 6.684 | 310.469 | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 9314.081 |
3 | BULK STORAGE AREA LIGHTS | LTG_SCH_BULK_STORAGE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 10866.415 | 3.391 | 157.484 | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 10866.415 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | OFFICE PLUG LOAD | OFFICE_PLUG_SCH | ZONE1 OFFICE | 236.88 | 12.7 | 1912.500 | 8.074 | 150.015 | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 1912.500 |
2 | BULK STORAGE PLUG LOAD | BULK STORAGE PLUG SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 8200.120 | 2.559 | 118.842 | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 8200.120 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | NONRES_ROOF | 16 | 2 | 2 | 0.167 | 0.1804 | 0.900 | 0.900 | 0.770 | 0.700 | Smooth |
2 | SEMIHEATED_ROOF | 18 | 2 | 2 | 0.167 | 0.1804 | 0.900 | 0.900 | 0.770 | 0.700 | Smooth |
3 | NONRES_EXT_WALL_GRD | 19 | 3 | 4 | 0.167 | 0.4095 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | SEMIHEATED_EXT_WALL_GRD | 25 | 3 | 4 | 0.167 | 0.4095 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | SWINGING DOOR_CON | 41 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
6 | SWINGING DOOR_SEMI | 42 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | OVERHEAD DOOR_SEMI | 44 | 1 | 1 | 0.167 | 1.198 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
8 | OVERHEAD DOOR_CON | 45 | 1 | 1 | 0.167 | 1.198 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
9 | BULK STORAGE PRODUCTS | 46 | 1 | 18 | 0.500 | 0.5914 | 0.900 | 0.900 | 0.700 | 0.700 | Rough |
10 | INTERIOR WALL | 47 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
11 | INSULATEDCEILING | 48 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
12 | OFFICEFLOOR_FFACTOR | 49 | 2 | 7 | 0.167 | 0.1413 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | FINESTORAGEFLOOR_FFACTOR | 50 | 2 | 7 | 0.167 | 0.5841E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | BULKSTORAGEFLOOR_FFACTOR | 51 | 2 | 7 | 0.167 | 0.5469E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | iz-INTERIOR WALL | 52 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
16 | iz-SEMIHEATED_EXT_WALL_GRD | 53 | 3 | 4 | 0.167 | 0.4095 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
17 | iz-INSULATEDCEILING | 54 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
2 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 5.544 |
3 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
4 | SEMIHEATED_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 5.544 |
5 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
6 | NONRES_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 2.343 |
7 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | SEMIHEATED_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 2.343 |
10 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
11 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
12 | OPAQUE DOOR PANEL_SEMI | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
13 | OVERHEAD DOOR_SEMI PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8346 |
14 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8346 |
15 | BULK STORAGE PRODUCTS MATERIAL | 2.4384 | 1.442 | 200.231 | 836.800 | 1.691 |
16 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
17 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
18 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
19 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
20 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
21 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
22 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
23 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.998 |
24 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
25 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 17.04 |
26 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
27 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 18.21 |
28 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
29 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
30 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
31 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
32 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
33 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
34 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
35 | SEMIHEATED_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 2.343 |
36 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
37 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
38 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 2 | 0.60435670E-09 | 0.47630797E-14 | 0.24204839E-14 | 0.0000000 |
2 | 1 | -5.2160796 | 0.57881174E-04 | -0.88809346E-04 | 0.11586416E-09 |
3 | 0 | 5.3964676 | 0.18033005 | 0.18047674 | |
4 | 2 | 0.60435670E-09 | 0.47630797E-14 | 0.24204839E-14 | 0.0000000 |
5 | 1 | -5.2160796 | 0.57881174E-04 | -0.88809346E-04 | 0.11586416E-09 |
6 | 0 | 5.3964676 | 0.18033005 | 0.18047674 | |
7 | 4 | 0.79647225E-12 | 0.96147816E-16 | -0.20666597E-14 | 0.11382549E-15 |
8 | 3 | -0.38972706E-03 | 0.28930881E-06 | -0.56581374E-04 | 0.15282143E-12 |
9 | 2 | 1.7513786 | 0.62914578E-02 | 1.1494565 | -0.74717338E-04 |
10 | 1 | -7.1131205 | 0.16244765 | -17.155584 | 0.33567575 |
11 | 0 | 5.6342095 | 0.10333854 | 16.278262 | |
12 | 4 | 0.79647225E-12 | 0.96147816E-16 | -0.20666597E-14 | 0.11382549E-15 |
13 | 3 | -0.38972706E-03 | 0.28930881E-06 | -0.56581374E-04 | 0.15282143E-12 |
14 | 2 | 1.7513786 | 0.62914578E-02 | 1.1494565 | -0.74717338E-04 |
15 | 1 | -7.1131205 | 0.16244765 | -17.155584 | 0.33567575 |
16 | 0 | 5.6342095 | 0.10333854 | 16.278262 | |
17 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
18 | 0 | 2.1009573 | 2.1009573 | 2.1009573 | |
19 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
20 | 0 | 2.1009573 | 2.1009573 | 2.1009573 | |
21 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
22 | 0 | 1.1981135 | 1.1981135 | 1.1981135 | |
23 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
24 | 0 | 1.1981135 | 1.1981135 | 1.1981135 | |
25 | 18 | 0.12003549E-12 | -0.36149852E-21 | 0.11999160E-12 | -0.69171859E-14 |
26 | 17 | -0.26702818E-10 | 0.22043783E-17 | -0.26702965E-10 | 0.15647703E-11 |
27 | 16 | 0.26199194E-08 | 0.46087291E-16 | 0.26199192E-08 | -0.15597178E-09 |
28 | 15 | -0.14918350E-06 | -0.27301975E-15 | -0.14918350E-06 | 0.90448703E-08 |
29 | 14 | 0.54929883E-05 | 0.10218664E-13 | 0.54929883E-05 | -0.34010628E-06 |
30 | 13 | -0.13812653E-03 | 0.13886261E-11 | -0.13812653E-03 | 0.87613853E-05 |
31 | 12 | 0.24466257E-02 | 0.76740851E-10 | 0.24466257E-02 | -0.15954016E-03 |
32 | 11 | -0.31099262E-01 | 0.20215154E-08 | -0.31099262E-01 | 0.20926433E-02 |
33 | 10 | 0.28694928 | 0.26940884E-07 | 0.28694928 | -0.20002833E-01 |
34 | 9 | -1.9353699 | 0.18750649E-06 | -1.9353699 | 0.14030665 |
35 | 8 | 9.5767226 | 0.68900696E-06 | 9.5767226 | -0.72468789 |
36 | 7 | -34.784653 | 0.13258951E-05 | -34.784653 | 2.7565275 |
37 | 6 | 92.438040 | 0.12976568E-05 | 92.438040 | -7.6923258 |
38 | 5 | -178.18614 | 0.60985027E-06 | -178.18614 | 15.604270 |
39 | 4 | 245.02895 | 0.12430126E-06 | 245.02895 | -22.615757 |
40 | 3 | -233.27712 | 0.91617964E-08 | -233.27712 | 22.714127 |
41 | 2 | 145.61910 | 0.16319500E-09 | 145.61910 | -14.964058 |
42 | 1 | -53.478849 | 0.26256209E-11 | -53.478849 | 5.7996512 |
43 | 0 | 8.7411694 | -0.39181092E-12 | 8.7411694 | |
44 | 5 | -0.68112304E-12 | 0.61645773E-13 | -0.20199983E-12 | 0.95058421E-15 |
45 | 4 | 0.71499529E-06 | 0.73238302E-07 | 0.28552134E-06 | -0.33479849E-12 |
46 | 3 | -0.58529659E-02 | 0.62218017E-03 | -0.21917430E-02 | 0.29169470E-06 |
47 | 2 | 1.2914758 | 0.88958368E-01 | 0.40042664 | -0.15953103E-02 |
48 | 1 | -8.6129398 | 0.38073474 | -3.1694576 | 0.22491773 |
49 | 0 | 7.9317533 | 0.13060792 | 3.3724149 | |
50 | 3 | -0.49407978E-15 | 0.44230608E-16 | -0.53860842E-16 | 0.0000000 |
51 | 2 | 0.54884850E-03 | 0.14309697E-03 | 0.26444340E-03 | -0.39739853E-15 |
52 | 1 | -3.9407614 | 2.0053241 | -3.6132068 | 0.31450573E-03 |
53 | 0 | 13.994357 | 8.0573072 | 13.672611 | |
54 | 7 | -0.30042996E-08 | -0.19492532E-14 | 0.18571942E-14 | -0.50265421E-16 |
55 | 6 | 0.40686135E-05 | 0.27025218E-08 | 0.31944093E-02 | -0.26797382E-04 |
56 | 5 | -0.28598357E-03 | 0.15982348E-05 | -0.22398257 | 0.19584275E-02 |
57 | 4 | 0.65354345E-02 | 0.72696005E-04 | 4.8338424 | -0.45306284E-01 |
58 | 3 | -0.57256805E-01 | 0.57768437E-03 | -38.045688 | 0.39892203 |
59 | 2 | 0.20312160 | 0.96045137E-03 | 116.53119 | -1.4185711 |
60 | 1 | -0.29305691 | 0.29236276E-03 | -143.93511 | 2.0494970 |
61 | 0 | 0.14285049 | 0.70905046E-05 | 60.838472 | |
62 | 7 | -0.73310212E-08 | 0.16277859E-15 | -0.15558641E-14 | 0.17403554E-16 |
63 | 6 | 0.21213446E-05 | 0.11327280E-08 | 0.32008460E-02 | -0.26851379E-04 |
64 | 5 | -0.12816801E-03 | 0.66411688E-06 | -0.22434819 | 0.19616548E-02 |
65 | 4 | 0.27852559E-02 | 0.30072908E-04 | 4.8399282 | -0.45364789E-01 |
66 | 3 | -0.23934818E-01 | 0.23808113E-03 | -38.080046 | 0.39930184 |
67 | 2 | 0.84241938E-01 | 0.39442809E-03 | 116.59803 | -1.4194653 |
68 | 1 | -0.12110434 | 0.11951395E-03 | -143.97445 | 2.0501436 |
69 | 0 | 0.58923671E-01 | 0.28881054E-05 | 60.838472 | |
70 | 7 | -0.78336681E-08 | 0.23380828E-15 | -0.37470831E-14 | 0.17001158E-16 |
71 | 6 | 0.20573783E-05 | 0.10635783E-08 | 0.32011355E-02 | -0.26853807E-04 |
72 | 5 | -0.12166809E-03 | 0.62270931E-06 | -0.22436462 | 0.19617998E-02 |
73 | 4 | 0.26229018E-02 | 0.28177105E-04 | 4.8402013 | -0.45367414E-01 |
74 | 3 | -0.22467346E-01 | 0.22293819E-03 | -38.081586 | 0.39931887 |
75 | 2 | 0.78971204E-01 | 0.36912476E-03 | 116.60102 | -1.4195054 |
76 | 1 | -0.11345740 | 0.11176675E-03 | -143.97621 | 2.0501725 |
77 | 0 | 0.55185584E-01 | 0.26976542E-05 | 60.838472 | |
78 | 5 | -0.20199983E-12 | 0.61645773E-13 | -0.68112304E-12 | 0.95058421E-15 |
79 | 4 | 0.28552134E-06 | 0.73238302E-07 | 0.71499529E-06 | -0.33479849E-12 |
80 | 3 | -0.21917430E-02 | 0.62218017E-03 | -0.58529659E-02 | 0.29169470E-06 |
81 | 2 | 0.40042664 | 0.88958368E-01 | 1.2914758 | -0.15953103E-02 |
82 | 1 | -3.1694576 | 0.38073474 | -8.6129398 | 0.22491773 |
83 | 0 | 3.3724149 | 0.13060792 | 7.9317533 | |
84 | 4 | -0.20666597E-14 | 0.96147816E-16 | 0.79647225E-12 | 0.11382549E-15 |
85 | 3 | -0.56581374E-04 | 0.28930881E-06 | -0.38972706E-03 | 0.15282143E-12 |
86 | 2 | 1.1494565 | 0.62914578E-02 | 1.7513786 | -0.74717338E-04 |
87 | 1 | -17.155584 | 0.16244765 | -7.1131205 | 0.33567575 |
88 | 0 | 16.278262 | 0.10333854 | 5.6342095 | |
89 | 3 | -0.53860842E-16 | 0.44230608E-16 | -0.49407978E-15 | 0.0000000 |
90 | 2 | 0.26444340E-03 | 0.14309697E-03 | 0.54884850E-03 | -0.39739853E-15 |
91 | 1 | -3.6132068 | 2.0053241 | -3.9407614 | 0.31450573E-03 |
92 | 0 | 13.672611 | 8.0573072 | 13.994357 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | Conductance (Before Adjusted) {W/m2-K} | Convection Coefficient Adjustment Ratio | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.3618_SHGC_SOUTH_0.4 | 34 | 1 | VerySmooth | 2.055 | 2.055 | 1.000 | 0.401 | ||
2 | NONRESWINDOW_U_0.3618_SHGC_NORTH_0.4 | 35 | 1 | VerySmooth | 2.055 | 2.055 | 1.000 | 0.401 | ||
3 | NONRESWINDOW_U_0.3618_SHGC_EAST_0.4 | 36 | 1 | VerySmooth | 2.055 | 2.055 | 1.000 | 0.401 | ||
4 | NONRESWINDOW_U_0.3618_SHGC_WEST_0.4 | 37 | 1 | VerySmooth | 2.055 | 2.055 | 1.000 | 0.401 | ||
5 | SKYLIGHT_U_0.75_SHGC_0.6 | 38 | 1 | VerySmooth | 4.262 | 4.262 | 1.000 | 0.605 | ||
6 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | 39 | 1 | VerySmooth | 4.262 | 4.262 | 1.000 | 0.605 | ||
7 | SKYLIGHT DOUBLE CLEAR | 43 | 3 | VerySmooth | 3.715 | 3.715 | 1.000 | 0.720 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER SOUTH | SpectralAverage | 3.63872E-002 | 0.31435 | 0.48135 | 0.48135 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.11595 | 1.00000 | No | |
2 | NONRES WINDOW GLAZING LAYER NORTH | SpectralAverage | 3.63872E-002 | 0.31435 | 0.48135 | 0.48135 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.11595 | 1.00000 | No | |
3 | NONRES WINDOW GLAZING LAYER EAST | SpectralAverage | 3.63872E-002 | 0.31435 | 0.48135 | 0.48135 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.11595 | 1.00000 | No | |
4 | NONRES WINDOW GLAZING LAYER WEST | SpectralAverage | 3.63872E-002 | 0.31435 | 0.48135 | 0.48135 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.11595 | 1.00000 | No | |
5 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.47441 | 0.15233 | 0.15233 | 0.60000 | 0.13030 | 0.15164 | 0.00000 | 0.84000 | 0.84000 | 2.99465E-002 | 1.00000 | No | |
6 | SEMIHEATED SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.47441 | 0.15233 | 0.15233 | 0.60000 | 0.13030 | 0.15164 | 0.00000 | 0.84000 | 0.84000 | 2.99465E-002 | 1.00000 | No | |
7 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No | |
8 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No |
Material Name | GasType | Thickness {m} | |
1 | AIR 3MM | Air | 3.200E-003 |
Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
Enclosure Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Enclosures | |
1 | ZONE1 OFFICE | 4 | 0 |
2 | ZONE3 BULK STORAGE | 10 | 0 |
Enclosure Name | Number of Adjacent Enclosures with Windows | Adjacent Enclosure Names - 1st 100 (max) | |
1 | ZONE1 OFFICE | 0 | |
2 | ZONE3 BULK STORAGE | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 7.5708E-002 | 6154.7 | 1.056 | 0.5354 |
Construction Name | Frame and Divider Name | NFRC Product Type | Assembly U-Factor {W/m2-K} | Assembly SHGC | Assembly Visible Transmittance | |
1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | CurtainWall | 4.099 | 0.605 | 0.602 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | OFFICE INFILTRATION | OFFICE INFIL SCHEDULE | ZONE1 OFFICE | 236.88 | 12.7 | 8.518E-002 | 3.596E-004 | 5.551E-004 | 0.303 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | OFFICE DOOR INFILTRATION | INFIL_DOOR_OPENING_SCH | ZONE1 OFFICE | 236.88 | 12.7 | 0.289 | 1.219E-003 | 1.882E-003 | 1.029 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | FINE STORAGE INFILTRATION | FINE SORAGE INFIL SCHEDULE | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 0.433 | 3.110E-004 | 1.981E-004 | 0.528 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | BULK STORAGE INFILTRATION | BULK STORAGE INFIL_BASE SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 2.710 | 8.455E-004 | 5.523E-004 | 0.277 | 0.000 | 0.000 | 0.224 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
1 | BULK STORAGE VENTILATION-1 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 37.760 | 1.178E-002 | 0.547 | 3.853 | Exhaust | 31.136 | 0.5 | 1.000 | 0.000 | 0.000 | 0.000 | 29.44 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
2 | BULK STORAGE VENTILATION-2 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 0.944 | 2.945E-004 | 1.368E-002 | 9.632E-002 | Natural | 0.000 | 1.0 | 0.000 | 0.000 | 0.224 | 0.000 | -73.33 | 29.44 | -100.00 | -100.00 | 100.00 | 40.00 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | ZONE1 OFFICE | Mixing/Well-Stirred |
2 | ZONE2 FINE STORAGE | Mixing/Well-Stirred |
3 | ZONE3 BULK STORAGE | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Sky Type | MonthAndDay | Daylighting Control Name | Enclosure Name | Window Name | Reference Point | Daylight Factor | |
1 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2591E-004 |
2 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.9231E-004 |
3 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9280E-004 |
4 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.5005E-004 |
5 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.4211E-004 |
6 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.3867E-004 |
7 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.2146E-004 |
8 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5679E-003 |
9 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1962E-003 |
10 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0125E-003 |
11 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7318E-003 |
12 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.7844E-003 |
13 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.7669E-004 |
14 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.8228E-004 |
15 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0598E-003 |
16 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5679E-003 |
17 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C5 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4091E-004 |
18 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C5 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.1151E-004 |
19 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C5 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.4725E-004 |
20 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C5 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.5005E-004 |
21 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.5846E-004 |
22 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.3135E-004 |
23 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.8137E-004 |
24 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.5005E-004 |
25 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.8726E-004 |
26 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.2061E-004 |
27 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4380E-003 |
28 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5679E-003 |
29 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.1960E-003 |
30 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.1752E-003 |
31 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.2370E-003 |
32 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.7844E-003 |
33 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1308E-003 |
34 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1069E-003 |
35 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7046E-003 |
36 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5679E-003 |
37 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C5 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.2272E-004 |
38 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C5 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.0444E-004 |
39 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C5 | ZONE3 BULK STORAGE_DAYLREFPT1 | 4.6215E-004 |
40 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C5 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.5005E-004 |
41 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 5.4511E-003 |
42 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 6.5972E-004 |
43 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 4.8356E-003 |
44 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 5.8759E-004 |
45 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 4.6708E-003 |
46 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 5.6187E-004 |
47 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 2.8599E-003 |
48 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 5.0221E-004 |
49 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 6.7365E-004 |
50 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 6.2478E-003 |
51 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 6.1795E-004 |
52 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 5.2239E-003 |
53 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 5.7361E-004 |
54 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 5.0610E-003 |
55 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 4.9649E-004 |
56 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 3.8464E-003 |
57 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 5.4718E-003 |
58 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 3.9498E-004 |
59 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 4.1529E-003 |
60 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 3.1176E-004 |
61 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 2.8746E-003 |
62 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 2.3262E-004 |
63 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 3.5869E-003 |
64 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 3.0592E-004 |
65 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 5.8196E-003 |
66 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 3.9620E-004 |
67 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 4.3269E-003 |
68 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 3.1242E-004 |
69 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 2.5468E-003 |
70 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 2.3192E-004 |
71 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 3.5869E-003 |
72 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 3.0592E-004 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | ZONE1 OFFICE | Cooling | 9795.21939 | 11754.26327 | 0.92141 | 1.10569 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 31.16000 | 6.30335E-003 | 236.87965 | 12.74874 | 0.10228 | 0.00000 |
2 | ZONE1 OFFICE | Heating | 11201.85855 | 13442.23026 | 0.35964 | 0.43157 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -27.60000 | 3.41898E-004 | 236.87965 | 12.74874 | 0.10228 | 0.00000 |
3 | ZONE2 FINE STORAGE | Cooling | 22064.52460 | 26477.42953 | 1.61785 | 1.94142 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | 33.08000 | 6.30633E-003 | 1393.40969 | 30.00000 | 0.42471 | 0.00000 |
4 | ZONE2 FINE STORAGE | Heating | 35576.23286 | 42691.47943 | 0.96175 | 1.15410 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | -27.60000 | 3.41898E-004 | 1393.40969 | 30.00000 | 0.42471 | 0.00000 |
5 | ZONE3 BULK STORAGE | Cooling | 0.00000 | 0.00000 | 0.00000 | 0.97684 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 33.24000 | 6.30658E-003 | 3204.84228 | 69.00000 | 0.97684 | 0.00000 |
6 | ZONE3 BULK STORAGE | Heating | 109577.65042 | 131493.18050 | 3.06109 | 3.67330 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | -27.60000 | 3.41898E-004 | 3204.84228 | 69.00000 | 0.97684 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-OFFICE | Cooling | Sensible | 14728.60 | 1.10569 | 1.10569 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
2 | PSZ-OFFICE | Heating | Sensible | 13920.67 | 0.43157 | 0.43157 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 |
3 | PSZ-FINE STORAGE | Cooling | Sensible | 33108.32 | 1.94142 | 1.94142 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
4 | PSZ-FINE STORAGE | Heating | Sensible | 49252.17 | 1.15410 | 1.15410 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ZONE1 OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.10569 |
2 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ZONE2 FINE STORAGE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.94142 |
3 | ZoneHVAC:UnitHeater | ZONE3 BULK STORAGE UNIT HEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 3.67330 |
4 | Fan:ConstantVolume | ZONE3UNITHEATER ZONE3HIRADIANT FAN | Design Size Maximum Flow Rate [m3/s] | 3.67330 |
5 | Coil:Heating:Fuel | ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | Design Size Nominal Capacity [W] | 131493.17071 |
6 | ZoneHVAC:HighTemperatureRadiant | ZONE3 BULK STORAGE HIRADIANT | User-Specified Heating Design Capacity [W] | 131493.18050 |
7 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.10569 |
8 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.10569 |
9 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.10569 |
10 | AirLoopHVAC | PSZ-OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 1.10569 |
11 | AirLoopHVAC | PSZ-OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.10569 |
12 | AirLoopHVAC | PSZ-OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 1.10569 |
13 | AirLoopHVAC | PSZ-OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
14 | AirLoopHVAC | PSZ-OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.94142 |
16 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.94142 |
17 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.94142 |
18 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Heating Design Air Flow Rate [m3/s] | 1.94142 |
19 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.94142 |
20 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Main Design Air Flow Rate [m3/s] | 1.94142 |
21 | AirLoopHVAC | PSZ-FINE STORAGE | User Heating Air Flow Ratio [] | 1.00000 |
22 | AirLoopHVAC | PSZ-FINE STORAGE | Calculated Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-OFFICE | Design Supply Air Flow Rate [m3/s] | 1.10569 |
24 | AirLoopHVAC | PSZ-FINE STORAGE | Design Supply Air Flow Rate [m3/s] | 1.94142 |
25 | Controller:OutdoorAir | PSZ-OFFICE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.10569 |
26 | Controller:OutdoorAir | PSZ-OFFICE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.10228 |
27 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.10569 |
28 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 1224.17300 |
29 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.10569 |
30 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.10569 |
31 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.10569 |
32 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.10569 |
33 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.10569 |
34 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.55284 |
35 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.73713 |
36 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 18303.08000 |
37 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 9151.54000 |
38 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.80066 |
39 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.80066 |
40 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 18303.08000 |
41 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 27439.47957 |
42 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
43 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
44 | Coil:Heating:Fuel | PSZ-OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 27439.47957 |
45 | Controller:OutdoorAir | PSZ-FINE STORAGE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.94142 |
46 | Controller:OutdoorAir | PSZ-FINE STORAGE_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.42471 |
47 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.94142 |
48 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 2077.41260 |
49 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.94142 |
50 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.94142 |
51 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.94142 |
52 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.28134 |
53 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.94142 |
54 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.97071 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.29428 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 38249.26000 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 19124.63000 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.78191 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.78191 |
60 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 38249.26000 |
61 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 69620.03881 |
62 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
63 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
64 | Coil:Heating:Fuel | PSZ-FINE STORAGE HEATING COIL | Design Size Nominal Capacity [W] | 69620.03881 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | 17445.1 | 12.15 | 11.88 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | 36741.8 | 11.79 | 11.53 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1Environment:Special Days |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | ZONE1 OFFICE | RunPeriod: RUNPERIOD 1 | 0.1948902165 | 0.1892719367 | Pass | Pass | 0.7205252844 | 2.1018207156 | Pass | Pass |
2 | ZONE2 FINE STORAGE | RunPeriod: RUNPERIOD 1 | 0.3993324636 | 0.3906113983 | Pass | Pass | 0.7608298871 | 2.9355789070 | Pass | Pass |
3 | ZONE3 BULK STORAGE | RunPeriod: RUNPERIOD 1 | 1.4269064494E-005 | 4.4221191013E-005 | Pass | Pass | 8.3010313860E-002 | 0.1054374078 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Heat Emission by ComponentsEnvelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
Heat Emissions [GJ] | 8270.65 | 698.22 | 0.00 | 74.73 | 224.13 | 9267.80 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | -27.60 | 0.00 | -27.60 | Wetbulb [C] | 2.70 | 230.00 |
GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 33.40 | 16.00 | 16.30 | Wetbulb [C] | 4.90 | 240.00 |
Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
Jan | 0.00 | 0 | |||
Feb | 0.00 | 0 | |||
Mar | 0.00 | 0 | |||
Apr | 11.00 | 18 | |||
May | 24.00 | 14 | |||
Jun | 29.00 | 21 | |||
Jul | 6.00 | 9 | |||
Aug | 0.00 | 0 | |||
Sep | 0.00 | 0 | |||
Oct | 0.00 | 0 | |||
Nov | 0.00 | 0 | |||
Dec | 0.00 | 0 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 110.54 | 97.44 | 270.00 | 90.00 | W |
OFFICE LEFT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 39.02 | 30.56 | 0.00 | 90.00 | N |
OFFICE FLOOR | OFFICEFLOOR_FFACTOR | 1.00 | 0.138 | 0.141 | 236.88 | 236.88 | 90.00 | 180.00 | |
FINE STORAGE FRONT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 169.07 | 161.64 | 270.00 | 90.00 | W |
FINE STORAGE RIGHT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 260.10 | 243.29 | 180.00 | 90.00 | S |
FINE STORAGE LEFT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 182.07 | 172.69 | 0.00 | 90.00 | N |
FINE STORAGE OFFICE FRONT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 110.54 | 110.54 | 270.00 | 90.00 | W |
FINE STORAGE OFFICE LEFT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 39.02 | 39.02 | 0.00 | 90.00 | N |
FINE STORAGE FLOOR | FINESTORAGEFLOOR_FFACTOR | 1.00 | 0.058 | 0.058 | 1156.53 | 1156.53 | 90.00 | 180.00 | |
FINE STORAGE ROOF | NONRES_ROOF | 0.23 | 0.176 | 0.180 | 1393.41 | 1393.41 | 90.00 | 0.00 | |
BULK STORAGE RIGHT WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 598.24 | 568.60 | 180.00 | 90.00 | S |
BULK STORAGE REAR WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 390.15 | 358.48 | 90.00 | 90.00 | E |
BULK STORAGE LEFT WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.386 | 0.410 | 598.24 | 544.27 | 0.00 | 90.00 | N |
BULK STORAGE FLOOR | BULKSTORAGEFLOOR_FFACTOR | 1.00 | 0.054 | 0.055 | 3204.84 | 3204.84 | 90.00 | 180.00 | |
BULK STORAGE ROOF | SEMIHEATED_ROOF | 0.23 | 0.176 | 0.180 | 3204.84 | 3189.98 | 270.00 | 0.00 |
Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE RIGHT WALL | INTERIOR WALL | 0.30 | 0.653 | 0.775 | 39.02 | 39.02 | 180.00 | 90.00 | S |
OFFICE REAR WALL | INTERIOR WALL | 0.30 | 0.653 | 0.775 | 110.54 | 110.54 | 90.00 | 90.00 | E |
OFFICE ROOF | INSULATEDCEILING | 0.30 | 2.711 | 10.063 | 236.88 | 236.88 | 90.00 | 0.00 | |
iz-OFFICE RIGHT WALL | iz-INTERIOR WALL | 0.30 | 0.653 | 0.775 | 39.02 | 39.02 | 0.00 | 90.00 | N |
iz-OFFICE REAR WALL | iz-INTERIOR WALL | 0.30 | 0.653 | 0.775 | 110.54 | 110.54 | 270.00 | 90.00 | W |
iz-BULK STORAGE FRONT WALL | iz-SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.373 | 0.410 | 390.15 | 390.15 | 270.00 | 90.00 | W |
iz-OFFICE ROOF | iz-INSULATEDCEILING | 0.30 | 2.711 | 10.063 | 236.88 | 236.88 | 270.00 | 180.00 | |
BULK STORAGE FRONT WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.373 | 0.410 | 390.15 | 390.15 | 90.00 | 90.00 | E |
BULK STORAGE PRODUCTS SURFACE | BULK STORAGE PRODUCTS | 0.30 | 0.591 | 6028.45 | 0.00 | 90.00 | N |
Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL WINDOW 1 | NONRESWINDOW_U_0.3618_SHGC_WEST_0.4 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 2.055 | 0.401 | 0.402 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | |||||||
OFFICE FRONT WALL WINDOW2 | NONRESWINDOW_U_0.3618_SHGC_WEST_0.4 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 2.055 | 0.401 | 0.402 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | |||||||
OFFICE LEFT WALL WINDOW1 | NONRESWINDOW_U_0.3618_SHGC_NORTH_0.4 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 2.055 | 0.401 | 0.402 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | |||||||
OFFICE LEFT WALL WINDOW2 | NONRESWINDOW_U_0.3618_SHGC_NORTH_0.4 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 2.055 | 0.401 | 0.402 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | |||||||
SKYLIGHT_R1C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C5 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C5 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
Total or Average | 32.53 | 3.064 | 0.494 | 0.493 | |||||||||||||||||
North Total or Average | 6.51 | 2.055 | 0.401 | 0.402 | |||||||||||||||||
Non-North Total or Average | 26.02 | 3.316 | 0.517 | 0.516 |
Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
None |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
OFFICE FRONT DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | OFFICE FRONT WALL |
OFFICE LEFT WALL DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | OFFICE LEFT WALL |
FINE STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_CON | 1.016 | 1.198 | 7.43 | FINE STORAGE FRONT WALL |
FINE STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_CON | 1.016 | 1.198 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_CON | 1.016 | 1.198 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE RIGHT DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_CON | 1.016 | 1.198 | 7.43 | FINE STORAGE LEFT WALL |
FINE STORAGE LEFT DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | FINE STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR8 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR9 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR10 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR11 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR1 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR2 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR3 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR12 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR13 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR14 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR15 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE DOOR4 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR5 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR6 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR7 | OVERHEAD DOOR_SEMI | 1.016 | 1.198 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE DOOR5 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE LEFT WALL |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
OFFICE FRONT WALL WINDOW 1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE FRONT WALL WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE LEFT WALL WINDOW1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
OFFICE LEFT WALL WINDOW2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
SKYLIGHT_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C5 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C5 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Interior LightingZone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
OFFICE LIGHTS | ZONE1 OFFICE | ZONE1 OFFICE | GENERAL | 7.6766 | 236.88 | 1818.43 | LightsWired | LTG_SCH_OFFICE | 49.99 | 168.00 | 44.93 | 0.0000 | Y | 15.34 |
FINE STORAGE AREA LIGHTS | ZONE2 FINE STORAGE | ZONE2 FINE STORAGE | GENERAL | 6.6844 | 1393.41 | 9314.08 | LightsWired | LTG_SCH_FINE_STORAGE | 34.09 | 168.00 | 33.37 | 0.0000 | Y | 58.34 |
BULK STORAGE AREA LIGHTS | ZONE3 BULK STORAGE | ZONE3 BULK STORAGE | GENERAL | 3.3906 | 3204.84 | 10866.42 | LightsWired | LTG_SCH_BULK_STORAGE | 34.09 | 168.00 | 31.27 | 0.0000 | Y | 63.79 |
Interior Lighting Total | 4.5498 | 4835.13 | 21998.92 | 137.47 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
ZONE3 BULK STORAGE_DAYLREFPT1 | ZONE3 BULK STORAGE | ZONE3 BULK STORAGE_DAYLCTRL | SplitFlux | Stepped | 0.12 | 10866.42 | 1260.50 |
ZONE1 OFFICE_DAYLREFPT1 | ZONE1 OFFICE | ZONE1 OFFICE_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1818.43 | 263.67 |
ZONE1 OFFICE_DAYLREFPT2 | ZONE1 OFFICE | ZONE1 OFFICE_DAYLCTRL | SplitFlux | Continuous/Off | 0.05 | 1818.43 | 90.92 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 93.17 | AstronomicalClock | - | 42.11 | 42.11 | 0.74 | |
EXTERIOR_LIGHTS_B | 5399.43 | AstronomicalClock | - | 83.57 | 71.13 | 72.09 | |
Exterior Lighting Total | 5492.60 | 72.83 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Central PlantType | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 18303.08 | 14654.54 | 3648.54 | 0.80 | 4.12 | |||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 38249.26 | 29907.48 | 8341.78 | 0.78 | 3.80 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-OFFICE COOLING COIL | 17445.1 | 12.15 | 11.88 | ||||
PSZ-FINE STORAGE COOLING COIL | 36741.8 | 11.79 | 11.53 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | Coil:Heating:Fuel | 131493.17 | 0.80 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | 27439.48 | 0.80 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | 69620.04 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
ZONE3UNITHEATER ZONE3HIRADIANT FAN | Fan:ConstantVolume | 0.54 | 49.80 | 3.67 | 341.29 | 92.91 | 1.00 | 3.27 | General | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 |
PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.56 | 622.50 | 1.11 | 1224.17 | 1107.16 | 1.00 | 1.38 | General | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.58 | 622.50 | 1.94 | 2077.41 | 1070.05 | 1.00 | 1.32 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SWHSYS1 WATER HEATER | WaterHeater:Mixed | 0.08 | 6154.75 | 1.00 | 1.06 | 0.54 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 9795.22 | 11754.26 | 49.62 | 0.921 | 1.106 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 23.90 | 23.90 | 0.00822 | 31.16 | 0.00630 | 0.102 | 0.00 |
ZONE2 FINE STORAGE | 22064.52 | 26477.43 | 19.00 | 1.618 | 1.941 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | 26.70 | 26.70 | 0.00813 | 33.08 | 0.00631 | 0.425 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 | 0.000 | 0.977 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 0.00 | 32.88 | 0.00638 | 33.24 | 0.00631 | 0.977 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 11201.86 | 13442.23 | 56.75 | 0.360 | 0.432 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 21.10 | 21.10 | 0.00772 | -27.60 | 0.00034 | 0.102 | 0.00 |
ZONE2 FINE STORAGE | 35576.23 | 42691.48 | 30.64 | 0.962 | 1.154 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | 15.56 | 15.55 | 0.00649 | -27.60 | 0.00034 | 0.425 | 0.00 |
ZONE3 BULK STORAGE | 109577.65 | 131493.18 | 41.03 | 3.061 | 3.673 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | 10.00 | 10.00 | 0.00540 | -27.60 | 0.00034 | 0.977 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-OFFICE | 1.11 | 1.11 | 0.43 | 0.43 | 1.1057 | 1.1057 | 1.1057 | 1.0000 | 1.0000 |
PSZ-FINE STORAGE | 1.94 | 1.94 | 1.15 | 1.15 | 1.9414 | 1.9414 | 1.9414 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER or ZONEHVAC:HIGHTEMPERATURERADIANT | ZONE3 BULK STORAGE UNIT HEATER or ZONE3 BULK STORAGE HIRADIANT | 131493.171 | 131493.171 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | 131493.17 | 131493.17 | 3.673303 | 10.00 | 6.45 | 0.00539619 | 43.33 | 20.56 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 0.0000 | 10.00 | 0.00539619 | 62.0775 | 131493.18 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-OFFICE | 18303.080 | 14654.544 | 1.105690 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 9151.54 | 9097.47 | 0.737127 | 25.64 | 15.20 | 0.00804029 | 12.00 | 10.08 | 0.00800000 | 31.59 | 0.00630401 | 15.77 | 13.8761 | 23.90 | 0.00821765 | 38.9408 | 9776.38 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-OFFICE | 27439.480 | 27439.480 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 27439.48 | 27439.48 | 1.105689 | 16.55 | 10.97 | 0.00704142 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 9.2508 | 21.10 | 0.00772436 | 43.4277 | 11201.86 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-FINE STORAGE | 38249.260 | 29907.479 | 1.941420 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | 19124.63 | 19124.63 | 1.294280 | 29.13 | 16.11 | 0.00773302 | 12.00 | 9.82 | 0.00773302 | 33.24 | 0.00630658 | 16.31 | 32.8145 | 26.70 | 0.00813300 | 32.6305 | 22041.11 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-FINE STORAGE | 69620.039 | 69620.039 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | 69620.04 | 69620.04 | 1.941421 | 6.11 | 4.30 | 0.00514850 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 21.8763 | 15.55 | 0.00649446 | 51.8097 | 35576.23 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER or ZONEHVAC:HIGHTEMPERATURERADIANT | ZONE3 BULK STORAGE UNIT HEATER or ZONE3 BULK STORAGE HIRADIANT | ZONE3 BULK STORAGE | N/A | N/A | N/A | Yes | No | unknown | No | 131493.171 | 131493.171 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | ZONE3UNITHEATER ZONE3HIRADIANT FAN | Fan:ConstantVolume | 3.673303 | 3.86850241 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | Sensible | 131493.17 | 131493.17 | 1.0000 | 3.86850241 | 3.673303 | 10.00 | 6.45 | 0.00539619 | 23640.6 | 43.33 | 20.56 | 0.00800000 | 64191.6 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 131493.17 | -27.60 | 0.00034190 | -27.60 | 0.00000000 | 0.0000 | 10.00 | 0.00539619 | 10.00 | 0.00539619 | 62.0775 | 131493.18 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 18303.080 | 14654.544 | 1.105690 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7865 | 1004.8586 | 1.0531 | PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 1.105689 | 1.16444496 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | Sensible | 9151.54 | 9097.47 | 1.0000 | 0.77629749 | 0.737127 | 25.64 | 15.20 | 0.00804029 | 46258.2 | 12.00 | 10.08 | 0.00800000 | 32244.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9151.54 | 31.59 | 0.00630401 | 15.77 | 0.10228463 | 13.8761 | 23.90 | 0.00821765 | 23.90 | 0.00821765 | 38.9408 | 9776.38 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 27439.480 | 27439.480 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 1.105689 | 1.16444496 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | Sensible | 27439.48 | 27439.48 | 1.0000 | 1.16444496 | 1.105689 | 16.55 | 10.97 | 0.00704142 | 34456.4 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27439.48 | -27.60 | 0.00034190 | -27.60 | 0.10228463 | 9.2508 | 21.05 | 0.00772436 | 21.10 | 0.00772436 | 43.4277 | 11201.86 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 38249.260 | 29907.479 | 1.941420 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.2153 | 1004.8586 | 1.0531 | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 1.941421 | 2.04458823 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | Sensible | 19124.63 | 19124.63 | 1.0000 | 1.36305788 | 1.294280 | 29.13 | 16.11 | 0.00773302 | 49028.4 | 12.00 | 9.82 | 0.00773302 | 31570.4 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 19124.63 | 33.24 | 0.00630658 | 16.31 | 0.42471127 | 32.8145 | 26.70 | 0.00813300 | 26.70 | 0.00813300 | 32.6305 | 22041.11 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 69620.039 | 69620.039 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 1.941421 | 2.04458823 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | Sensible | 69620.04 | 69620.04 | 1.0000 | 2.04458823 | 1.941421 | 6.11 | 4.30 | 0.00514850 | 19078.0 | 40.00 | 19.63 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 69620.04 | -27.60 | 0.00034190 | -27.60 | 0.42471127 | 21.8763 | 15.55 | 0.00649446 | 15.55 | 0.00649446 | 51.8097 | 35576.23 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-OFFICE_OA_CONTROLLER | DifferentialDryBulb | 0.10 | 1.11 | - | |||
PSZ-FINE STORAGE_OA_CONTROLLER | DifferentialDryBulb | 0.42 | 1.94 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
ZONE1 OFFICE | 2618.50 | 3037.67 | 2287.17 |
ZONE2 FINE STORAGE | 3131.50 | 3043.33 | 2606.67 |
ZONE3 BULK STORAGE | 3217.50 | 3293.50 | 2965.83 |
Facility | 3403.50 | 3335.67 | 2987.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
ZONE1 OFFICE | 109.67 | 0.00 | 33.00 | 0.00 |
ZONE2 FINE STORAGE | 520.17 | 4.33 | 28.00 | 0.00 |
ZONE3 BULK STORAGE | 5.67 | 0.00 | 3.00 | 0.00 |
Facility | 606.00 | 4.33 | 52.17 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 9.45 | 12.75 | 1010.76 | 0.564 | 0.482 | 0.000 | 0.000 |
ZONE2 FINE STORAGE | 22.23 | 30.00 | 2953.02 | 0.449 | 0.325 | 0.000 | 0.000 |
ZONE3 BULK STORAGE | 51.12 | 69.00 | 35277.63 | 0.000 | 0.199 | 0.000 | 0.119 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 9.45 | 12.75 | 1010.76 | 0.000 | 0.000 | 0.000 | 0.000 |
ZONE2 FINE STORAGE | 22.23 | 30.00 | 2953.02 | 0.000 | 0.000 | 0.000 | 0.000 |
ZONE3 BULK STORAGE | 51.12 | 69.00 | 35277.63 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Mechanical Ventilation Parameters by ZoneAirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
ZONE1 OFFICE | PSZ-OFFICE | 9.45 | 12.75 | 1010.76 | 236.88 | 0.1023 | 0.102 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 22.23 | 30.00 | 2953.02 | 1393.41 | 0.4247 | 0.425 |
ZONE3 BULK STORAGE | 51.12 | 69.00 | 35277.63 | 3204.84 | 0.977 | ||
Total Facility | 82.79 | 111.75 | 39241.41 | 4835.13 | 0.5270 | 1.504 |
Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
ZONE1 OFFICE | 2039411.39 | 0.00 | 2039411.39 | 2708903.35 | 4748314.74 | 3225648.14 | 5715.89 | 2527.71 | 516.40 | 0.00 |
ZONE2 FINE STORAGE | 4818961.78 | 0.00 | 4818961.78 | 8997871.09 | 13816832.87 | 13393694.68 | 5728.65 | 2911.57 | 119.78 | 1.35 |
ZONE3 BULK STORAGE | 0.00 | 29539897.81 | 29539897.81 | 51863308.99 | 81403206.80 | 30805497.77 | 6815.42 | 87.00 | 1857.58 | 5018.94 |
Total Facility | 6858373.17 | 29539897.81 | 36398270.98 | 63570083.43 | 99968354.41 | 47424840.58 | 7801.17 | 3043.17 | 2348.84 | 5018.94 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
ZONE1 OFFICE | 0.1558 | 0.0000 | 0.1558 | 0.1338 | 0.2896 | 0.1023 | 591.89 | 2527.71 | 516.40 |
ZONE2 FINE STORAGE | 0.3678 | 0.0000 | 0.3678 | 0.2666 | 0.6344 | 0.4247 | 606.00 | 2911.57 | 118.43 |
ZONE3 BULK STORAGE | 0.0000 | 1.1610 | 1.1610 | 1.9741 | 3.1351 | 0.9768 | 2577.50 | 40.50 | 1018.00 |
Total Facility | 0.5236 | 1.1610 | 1.6846 | 2.3745 | 4.0591 | 1.5038 | 2677.17 | 2996.67 | 1508.11 |
Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
PSZ-OFFICE | 2261918.53 | 0.00 | 2261918.53 | 3225648.14 | 5715.39 | 0.00 | 3044.61 | 0.00 |
PSZ-FINE STORAGE | 5344721.32 | 0.00 | 5344721.32 | 13393694.68 | 5728.65 | 0.00 | 3031.35 | 1.35 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
PSZ-OFFICE | 0.1728 | 0.0000 | 0.1728 | 0.1023 | 591.39 | 0.00 | 3044.61 |
PSZ-FINE STORAGE | 0.4079 | 0.0000 | 0.4079 | 0.4247 | 606.00 | 0.00 | 3030.00 |
No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
PSZ-OFFICE | 0.00 | 2789.59 | 257.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PSZ-FINE STORAGE | 0.00 | 3007.05 | 24.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
PSZ-OFFICE | 0.0000 | 0.1835 | 0.4538 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
PSZ-FINE STORAGE | 0.0000 | 0.4876 | 0.7571 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Surfaces by ClassTotal | Outdoors | |
Wall | 16 | 10 |
Floor | 4 | 3 |
Roof | 3 | 2 |
Internal Mass | 1 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 14 | 14 |
Door | 28 | 28 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 2 |
Conditioned Zones | 3 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 389 |
Defaulted Fields | 319 |
Fields with Defaults | 1046 |
Autosized Fields | 43 |
Autosizable Fields | 97 |
Autocalculated Fields | 92 |
Autocalculatable Fields | 134 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 414.97 | 2297.60 | 26-MAR-14:10 | 33291.51 | 10-AUG-15:00 |
Electricity:Building | 277.28 | 1814.60 | 05-MAR-13:00 | 22430.82 | 07-AUG-12:30 |
Electricity:Zone:ZONE1 OFFICE | 47.28 | 774.00 | 05-MAR-13:00 | 2976.64 | 02-JAN-08:10 |
Electricity:SpaceType:GENERAL | 276.76 | 1814.60 | 05-MAR-13:00 | 20598.43 | 19-JAN-09:10 |
InteriorLights:Electricity | 137.47 | 1240.85 | 05-MAR-13:00 | 10485.81 | 19-JAN-09:10 |
InteriorLights:Electricity:Zone:ZONE1 OFFICE | 15.34 | 200.25 | 05-MAR-13:00 | 1064.14 | 02-JAN-08:10 |
InteriorLights:Electricity:SpaceType:GENERAL | 137.47 | 1240.85 | 05-MAR-13:00 | 10485.81 | 19-JAN-09:10 |
LightsWired:InteriorLights:Electricity | 137.47 | 1240.85 | 05-MAR-13:00 | 10485.81 | 19-JAN-09:10 |
LightsWired:InteriorLights:Electricity:Zone:ZONE1 OFFICE | 15.34 | 200.25 | 05-MAR-13:00 | 1064.14 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 137.47 | 1240.85 | 05-MAR-13:00 | 10485.81 | 19-JAN-09:10 |
Electricity:Zone:ZONE2 FINE STORAGE | 58.34 | 512.27 | 01-JAN-00:10 | 4354.33 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:ZONE2 FINE STORAGE | 58.34 | 512.27 | 01-JAN-00:10 | 4354.33 | 02-JAN-09:10 |
LightsWired:InteriorLights:Electricity:Zone:ZONE2 FINE STORAGE | 58.34 | 512.27 | 01-JAN-00:10 | 4354.33 | 02-JAN-09:10 |
Electricity:Zone:ZONE3 BULK STORAGE | 171.65 | 528.33 | 08-JAN-10:30 | 15192.61 | 05-AUG-14:40 |
InteriorLights:Electricity:Zone:ZONE3 BULK STORAGE | 63.79 | 528.33 | 08-JAN-10:30 | 5080.05 | 02-JAN-09:10 |
LightsWired:InteriorLights:Electricity:Zone:ZONE3 BULK STORAGE | 63.79 | 528.33 | 08-JAN-10:30 | 5080.05 | 02-JAN-09:10 |
InteriorEquipment:Electricity | 139.29 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE1 OFFICE | 31.95 | 573.75 | 01-JAN-00:10 | 1912.50 | 02-JAN-08:10 |
InteriorEquipment:Electricity:SpaceType:GENERAL | 139.29 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity | 139.29 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ZONE1 OFFICE | 31.95 | 573.75 | 01-JAN-00:10 | 1912.50 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 139.29 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE3 BULK STORAGE | 107.34 | 0.00 | 01-JAN-00:10 | 8200.12 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ZONE3 BULK STORAGE | 107.34 | 0.00 | 01-JAN-00:10 | 8200.12 | 02-JAN-08:10 |
Fans:Electricity | 33.63 | 0.00 | 14-JAN-18:10 | 4497.77 | 10-AUG-15:10 |
Fans:Electricity:Zone:ZONE3 BULK STORAGE | 0.52 | 0.00 | 01-JAN-00:10 | 2305.29 | 26-JUL-13:50 |
Ventilation (simple):Fans:Electricity | 0.52 | 0.00 | 01-JAN-00:10 | 2305.29 | 26-JUL-13:50 |
Ventilation (simple):Fans:Electricity:Zone:ZONE3 BULK STORAGE | 0.52 | 0.00 | 01-JAN-00:10 | 2305.29 | 26-JUL-13:50 |
ElectricityPurchased:Facility | 414.97 | 2297.60 | 16-JUL-15:00 | 33291.51 | 10-AUG-15:00 |
ElectricityPurchased:Plant | 414.97 | 2297.60 | 16-JUL-15:00 | 33291.51 | 10-AUG-15:00 |
Cogeneration:ElectricityPurchased | 414.97 | 2297.60 | 16-JUL-15:00 | 33291.51 | 10-AUG-15:00 |
General:Cogeneration:ElectricityPurchased | 414.97 | 2297.60 | 16-JUL-15:00 | 33291.51 | 10-AUG-15:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 414.97 | 2297.60 | 16-JUL-15:00 | 33291.51 | 10-AUG-15:00 |
ElectricityNet:Plant | 414.97 | 2297.60 | 16-JUL-15:00 | 33291.51 | 10-AUG-15:00 |
Cogeneration:ElectricityNet | 414.97 | 2297.60 | 16-JUL-15:00 | 33291.51 | 10-AUG-15:00 |
General:Cogeneration:ElectricityNet | 414.97 | 2297.60 | 16-JUL-15:00 | 33291.51 | 10-AUG-15:00 |
Electricity:HVAC | 38.34 | 0.00 | 14-JAN-18:10 | 11922.11 | 17-JUL-16:00 |
General:Fans:Electricity | 33.11 | 0.00 | 14-JAN-18:10 | 3395.24 | 05-JAN-16:10 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 5.23 | 0.00 | 01-JAN-00:10 | 9527.25 | 17-JUL-16:00 |
General:Cooling:Electricity | 5.23 | 0.00 | 01-JAN-00:10 | 9527.25 | 17-JUL-16:00 |
ExteriorLights:Electricity | 72.83 | 0.00 | 01-JAN-08:20 | 5492.60 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 72.83 | 0.00 | 01-JAN-08:20 | 5492.60 | 01-JAN-06:10 |
Electricity:Plant | 26.52 | 483.00 | 05-JAN-20:00 | 2841.61 | 18-FEB-13:00 |
WaterSystems:Electricity | 26.52 | 483.00 | 05-JAN-20:00 | 2841.61 | 18-FEB-13:00 |
Water Heater:WaterSystems:Electricity | 26.52 | 483.00 | 05-JAN-20:00 | 2841.61 | 18-FEB-13:00 |
Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
NaturalGas:Facility | 827.83 | 0.00 | 01-JAN-14:00 | 271217.70 | 05-JAN-17:10 |
NaturalGas:HVAC | 827.83 | 0.00 | 01-JAN-14:00 | 271217.70 | 05-JAN-17:10 |
Heating:NaturalGas | 827.83 | 0.00 | 01-JAN-14:00 | 271217.70 | 05-JAN-17:10 |
General:Heating:NaturalGas | 827.83 | 0.00 | 01-JAN-14:00 | 271217.70 | 05-JAN-17:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
EnergyTransfer:Facility | 1292.77 | 0.00 | 14-JAN-18:10 | 411880.00 | 05-JAN-17:10 |
EnergyTransfer:Building | 639.71 | 0.00 | 14-JAN-18:10 | 202093.17 | 06-JAN-07:10 |
EnergyTransfer:Zone:ZONE1 OFFICE | 59.26 | 0.00 | 01-JAN-00:10 | 28420.44 | 11-JAN-07:20 |
Heating:EnergyTransfer | 608.27 | 0.00 | 14-JAN-18:10 | 202093.17 | 06-JAN-07:10 |
Heating:EnergyTransfer:Zone:ZONE1 OFFICE | 47.16 | 0.00 | 01-JAN-00:10 | 28420.44 | 11-JAN-07:20 |
General:Heating:EnergyTransfer | 608.27 | 0.00 | 14-JAN-18:10 | 202093.17 | 06-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:ZONE1 OFFICE | 47.16 | 0.00 | 01-JAN-00:10 | 28420.44 | 11-JAN-07:20 |
Cooling:EnergyTransfer | 31.44 | 0.00 | 01-JAN-00:10 | 25805.90 | 17-JUL-16:10 |
Cooling:EnergyTransfer:Zone:ZONE1 OFFICE | 12.10 | 0.00 | 01-JAN-00:10 | 11153.33 | 17-JUL-16:10 |
General:Cooling:EnergyTransfer | 31.44 | 0.00 | 01-JAN-00:10 | 25805.90 | 17-JUL-16:10 |
General:Cooling:EnergyTransfer:Zone:ZONE1 OFFICE | 12.10 | 0.00 | 01-JAN-00:10 | 11153.33 | 17-JUL-16:10 |
EnergyTransfer:Zone:ZONE2 FINE STORAGE | 159.34 | 0.00 | 01-JAN-00:40 | 48420.85 | 10-JAN-23:00 |
Heating:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 140.00 | 0.00 | 01-JAN-00:40 | 48420.85 | 10-JAN-23:00 |
General:Heating:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 140.00 | 0.00 | 01-JAN-00:40 | 48420.85 | 10-JAN-23:00 |
Cooling:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 19.34 | 0.00 | 01-JAN-00:10 | 16154.00 | 17-JUL-16:00 |
General:Cooling:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 19.34 | 0.00 | 01-JAN-00:10 | 16154.00 | 17-JUL-16:00 |
EnergyTransfer:Zone:ZONE3 BULK STORAGE | 421.11 | 0.00 | 02-JAN-11:20 | 132889.28 | 05-JAN-15:30 |
Heating:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 421.11 | 0.00 | 02-JAN-11:20 | 132889.28 | 05-JAN-15:30 |
General:Heating:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 421.11 | 0.00 | 02-JAN-11:20 | 132889.28 | 05-JAN-15:30 |
Cooling:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cooling:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 653.07 | 0.00 | 01-JAN-14:00 | 214657.27 | 05-JAN-17:10 |
HeatingCoils:EnergyTransfer | 631.00 | 0.00 | 01-JAN-14:00 | 214657.27 | 05-JAN-17:10 |
CoolingCoils:EnergyTransfer | 22.07 | 0.00 | 01-JAN-00:10 | 34181.05 | 17-JUL-16:10 |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
ZONE1 OFFICE | 0.000 | 0.000 | 47.157 | -12.098 | 0.000 | 0.000 | 10.234 | 15.335 | 31.946 | 12.236 | 0.000 | 0.810 | 0.000 | 0.000 | -9.351 | 0.000 | -38.510 | -57.761 |
ZONE2 FINE STORAGE | 0.000 | 0.000 | 140.001 | -19.340 | 0.000 | 0.000 | 27.475 | 58.344 | 0.000 | 0.000 | 0.000 | 1.396 | 0.001 | 0.000 | 0.000 | 0.000 | -104.407 | -103.468 |
ZONE3 BULK STORAGE | 421.109 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 69.982 | 63.792 | 107.344 | 148.634 | 0.000 | 32.985 | 0.000 | 0.000 | -65.682 | 0.000 | -560.277 | -217.886 |
Total Facility | 421.109 | 0.000 | 187.158 | -31.438 | 0.000 | 0.000 | 107.691 | 137.471 | 139.290 | 160.870 | 0.000 | 35.191 | 0.001 | 0.000 | -75.033 | 0.000 | -703.194 | -379.115 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 09-SEP-07:02 | 0.00 | 0.00 | 0.00 | -23370.96 | 0.00 | 0.00 | 801.61 | 998.64 | 1912.50 | 0.00 | 0.00 | 0.00 | 20363.75 | 0.00 | -104.24 | 0.00 | -601.29 | 0.00 |
ZONE2 FINE STORAGE | 19-JUL-17:08 | 0.00 | 0.00 | 0.00 | -33881.45 | 0.00 | 0.00 | 0.00 | 512.27 | 0.00 | 0.00 | 0.00 | 1868.45 | 31500.72 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 19-JUL-17:08 | 0.00 | 0.00 | 0.00 | -33881.45 | 0.00 | 0.00 | 0.00 | 1240.85 | 2623.78 | 34973.29 | 0.00 | 8710.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -13667.24 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 26-JAN-06:42 | 0.00 | 0.00 | 28858.50 | 0.00 | 0.00 | 0.00 | 151.35 | 317.86 | 573.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1145.16 | 0.00 | -3654.94 | -25101.36 |
ZONE2 FINE STORAGE | 06-JAN-03:21 | 0.00 | 0.00 | 72954.04 | 0.00 | 0.00 | 0.00 | 0.00 | 512.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -13763.92 | -59702.40 |
ZONE3 BULK STORAGE | 05-JAN-15:30 | 132882.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8432.79 | 4883.62 | 8200.12 | 0.00 | 0.00 | 0.00 | 15107.01 | 0.00 | -4205.98 | 0.00 | -165299.66 | 0.00 |
Total Facility | 30-JAN-06:41 | 124342.49 | 0.00 | 97403.04 | 0.00 | 0.00 | 0.00 | 1452.07 | 1427.79 | 2623.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -8192.35 | 0.00 | -111020.69 | -108036.13 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 1.1057 | 0.0000 | 12.7487 | 1.0000 | Calculated from schedules | 0.1023 | 1.1057 | 0.0925 | 1.0000 | Not calculated | 0.1023 | 0.0925 | ||
PSZ-FINE STORAGE | 1.9414 | 0.0000 | 30.0000 | 1.0000 | Calculated from schedules | 0.4247 | 1.9414 | 0.2188 | 1.0000 | Not calculated | 0.4247 | 0.2188 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 1.1057 | 0.0000 | 12.7487 | 1.0000 | Calculated from schedules | 0.1023 | 1.1057 | 1.0000 | 1.0000 | Not calculated | 0.1023 | 0.0925 | ||
PSZ-FINE STORAGE | 1.9414 | 0.0000 | 30.0000 | 1.0000 | Calculated from schedules | 0.4247 | 1.9414 | 1.0000 | 1.0000 | Not calculated | 0.4247 | 0.2188 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
ZONE1 OFFICE | PSZ-OFFICE | 0.000000 | 12.7487 | 0.000432 | 236.88 | 0.1023 | 1.0000 | 0.1023 | 1.000 | 0.1023 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 0.000000 | 30.0000 | 0.000305 | 1393.41 | 0.4247 | 1.0000 | 0.4247 | 1.000 | 0.4247 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-OFFICE | 0.000000 | 12.75 | 0.000432 | 236.8796 | 0.1023 | 0.1023 | 0.1023 |
PSZ-FINE STORAGE | 0.000000 | 30.00 | 0.000305 | 1393.4097 | 0.4247 | 0.4247 | 0.4247 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.1057 | 1.1057 | 1.1057 | No | 0.1023 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.9414 | 1.9414 | 1.9414 | No | 0.4247 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 1.1057 | 1.1057 | 1.1057 | 1.1057 | 0.1023 | 1.0000 |
PSZ-FINE STORAGE | 1.9414 | 1.9414 | 1.9414 | 1.9414 | 0.4247 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.1057 | 1.1057 | 1.1057 | No | 0.1023 | 0.2370 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 1.9414 | 1.9414 | 1.9414 | No | 0.4247 | 0.3680 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 1.1057 | 1.1057 | 1.1057 | 1.1057 | 0.1023 | 1.0000 |
PSZ-FINE STORAGE | 1.9414 | 1.9414 | 1.9414 | 1.9414 | 0.4247 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Great Falls Intl Arpt MT USA TMY3 WMO#=727750 |
Total gross floor area [m2] | 4835.13 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
ZONE1 OFFICE | 236.88 | 236.88 | 0.00 | 69.73 |
ZONE2 FINE STORAGE | 1393.41 | 1393.41 | 0.00 | 69.73 |
ZONE3 BULK STORAGE | 3204.84 | 3204.84 | 0.00 | 69.73 |
Totals | 4835.13 | 4835.13 | 0.00 |
Data | |
Number of hours heating loads not met | 52.17 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 52.17 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- General | 0.00 | 0.00 | 827.83 | 271217.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- General | 5.23 | 9527.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 137.47 | 10485.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 72.83 | 5492.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 139.29 | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- Ventilation (simple) | 0.52 | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 33.11 | 3395.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 26.52 | 2841.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 139.29 | 414.97 |
Natural Gas | 0.00 | 827.83 |
Additional | 0.00 | 0.00 |
Total | 139.29 | 1242.80 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 28.43 |
Space Heating | 0.00 |
Space Cooling | 1.08 |
Fans (All) | 6.95 |
Service Water Heating | 5.48 |
Receptacle Equipment | 28.81 |
Miscellaneous (All) | 85.82 |
Subtotal | 85.82 |
Natural Gas [MJ/m2] | |
Space Heating | 171.21 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 171.21 |
Subtotal | 171.21 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 11.06 |
Space Heating | 66.61 |
Space Cooling | 0.42 |
Fans (All) | 2.71 |
Service Water Heating | 2.13 |
Receptacle Equipment | 11.21 |
Miscellaneous | 5.86 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
LTG_SCH_OFFICE | 2607. | 8760. |
LTG_SCH_BULK_STORAGE | 1777. | 8760. |
LTG_SCH_FINE_STORAGE | 1777. | 8760. |
OFFICE_PLUG_SCH | 4700. | 8760. |
BULK STORAGE PLUG SCHEDULE | 3744. | 7488. |
BLDG_OCC_SCH | 2861. | 3744. |
OFFICE PEOPLE SCHEDULE | 2861. | 3744. |
FANSCHED | 3432. | 3432. |
MINOA_MOTORIZEDDAMPER_SCHED | 3120. | 3120. |
OFFICE DHW SCHEDULE | 1825. | 5016. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 5550. | 8760. |
EXTERIOR LIGHT SCHEDULE | 5475. | 5475. |
ALWAYS OFF SCHEDULE | 0. | 0. |
OA DAMPER OFF DURING OFF HRS SCHEDULE | 2808. | 2808. |
OA DAMPER ALWAYS ON SCHEDULE | 8760. | 8760. |
MINOA_SCHED | 8760. | 8760. |
ALWAYS ON SCHEDULE | 8760. | 8760. |
EXTERIOR_LTG_SCH | 4380. | 4380. |
INFIL_DOOR_OPENING_SCH | 1154. | 3380. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 2600. | 2600. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 6935. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
BULK STORAGE HEATING SETPOINT SCHEDULE | ZONE3 BULK STORAGE HEATING SP | January | 10.00 | 365 | 10.00 | 365 |
OFFICE HEATING SCHEDULE | ZONE1 OFFICE DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
OFFICE COOLING SCHEDULE | ZONE1 OFFICE DUAL SP CONTROL | July | 23.90 | 365 | 29.40 | 365 |
FINE STORAGE HEATING SETPOINT SCHEDULE | ZONE2 FINE STORAGE DUAL SP CONTROL | January | 15.56 | 365 | 15.56 | 365 |
FINE STORAGE COOLING SETPOINT SCHEDULE | ZONE2 FINE STORAGE DUAL SP CONTROL | July | 26.70 | 365 | 26.70 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Heat Index HoursSafe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
ZONE1 OFFICE | 8629.33 | 130.67 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 8726.83 | 33.17 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 8474.50 | 285.50 | 0.00 | 0.00 | 0.00 |
Min | 8474.50 | 33.17 | 0.00 | 0.00 | 0.00 |
Max | 8726.83 | 285.50 | 0.00 | 0.00 | 0.00 |
Average | 8610.22 | 149.78 | 0.00 | 0.00 | 0.00 |
Sum | 25830.67 | 449.33 | 0.00 | 0.00 | 0.00 |
Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
ZONE1 OFFICE | 33027.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 82012.00 | 707.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 180400.67 | 10792.33 | 0.00 | 0.00 | 0.00 |
Min | 33027.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 180400.67 | 10792.33 | 0.00 | 0.00 | 0.00 |
Average | 98479.89 | 3833.11 | 0.00 | 0.00 | 0.00 |
Sum | 295439.67 | 11499.33 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
ZONE1 OFFICE | 8706.50 | 53.50 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 8690.00 | 70.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 8633.50 | 126.50 | 0.00 | 0.00 | 0.00 |
Min | 8633.50 | 53.50 | 0.00 | 0.00 | 0.00 |
Max | 8706.50 | 126.50 | 0.00 | 0.00 | 0.00 |
Average | 8676.67 | 83.33 | 0.00 | 0.00 | 0.00 |
Sum | 26030.00 | 250.00 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
ZONE1 OFFICE | 33024.00 | 3.00 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 81476.50 | 1242.50 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 185654.83 | 5538.17 | 0.00 | 0.00 | 0.00 |
Min | 33024.00 | 3.00 | 0.00 | 0.00 | 0.00 |
Max | 185654.83 | 5538.17 | 0.00 | 0.00 | 0.00 |
Average | 100051.78 | 2261.22 | 0.00 | 0.00 | 0.00 |
Sum | 300155.33 | 6783.67 | 0.00 | 0.00 | 0.00 |
SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
None |
SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
CO2 Level HoursSafe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 10:43:55
Illuminance Level HoursA Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
ZONE1 OFFICE | 0.00 | 0.00 | 8760.00 | 0.00 |
ZONE2 FINE STORAGE | 0.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 8760.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 8760.00 | 8760.00 | 0.00 |
Average | 0.00 | 2920.00 | 2920.00 | 0.00 |
Sum | 0.00 | 8760.00 | 8760.00 | 0.00 |
A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
ZONE1 OFFICE | 0.00 | 0.00 | 33027.00 | 0.00 |
ZONE2 FINE STORAGE | 0.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 191193.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 191193.00 | 33027.00 | 0.00 |
Average | 0.00 | 63731.00 | 11009.00 | 0.00 |
Sum | 0.00 | 191193.00 | 33027.00 | 0.00 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2018
For: Environment
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
For: Environment
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 6B
For: Environment
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MT_GREATFALLS
For: Environment
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: ZoneCoolingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 152608.60 | 763.04 | 14-JAN-08:07 | 3.98 | 1.76 | 0.493194E+09 | 603.28 | 14-JAN-08:20 | 4.07 | 1.84 |
February | 30960.51 | 135.70 | 25-FEB-08:07 | 4.37 | -1.1 | 0.454650E+09 | 667.77 | 27-FEB-16:10 | 17.78 | 6.92 |
March | 350599.03 | 668.45 | 25-MAR-07:07 | -4.3 | -5.6 | 0.532967E+09 | 609.19 | 18-MAR-15:09 | -4.3 | -5.6 |
April | 2085202.15 | 1025.05 | 13-APR-07:07 | 2.32 | 0.46 | 0.502505E+09 | 754.38 | 07-APR-14:00 | 2.32 | 0.46 |
May | 0.179564E+09 | 3464.16 | 19-MAY-16:00 | 27.80 | 14.54 | 0.554541E+09 | 768.97 | 31-MAY-12:09 | 21.28 | 9.59 |
June | 0.198885E+10 | 18326.80 | 24-JUN-07:02 | 17.07 | 13.08 | 0.638930E+09 | 879.39 | 24-JUN-07:10 | 17.07 | 13.08 |
July | 0.447311E+10 | 22007.06 | 29-JUL-07:02 | 14.60 | 9.36 | 0.636384E+09 | 879.39 | 20-JUL-07:10 | 14.60 | 9.36 |
August | 0.392301E+10 | 22019.68 | 26-AUG-07:02 | 14.68 | 9.29 | 0.681766E+09 | 879.39 | 12-AUG-07:10 | 14.68 | 9.29 |
September | 0.148348E+10 | 23371.23 | 09-SEP-07:02 | 14.37 | 7.94 | 0.589523E+09 | 879.39 | 02-SEP-07:10 | 14.37 | 7.94 |
October | 44658347.71 | 1673.32 | 18-OCT-16:00 | 24.40 | 11.02 | 0.525927E+09 | 768.97 | 16-OCT-14:39 | 24.40 | 11.02 |
November | 2173466.83 | 1432.28 | 18-NOV-08:07 | -1.4 | -2.5 | 0.475613E+09 | 694.81 | 04-NOV-15:09 | -1.4 | -2.5 |
December | 384347.29 | 1408.13 | 09-DEC-08:07 | -4.9 | -5.5 | 0.493471E+09 | 603.25 | 02-DEC-15:39 | -4.9 | -5.5 |
Annual Sum or Average | 0.120979E+11 | 0.657947E+10 | ||||||||
Minimum of Months | 30960.51 | 135.70 | -4.9 | -5.6 | 0.454650E+09 | 603.25 | -4.9 | -5.6 | ||
Maximum of Months | 0.447311E+10 | 23371.23 | 27.80 | 14.54 | 0.681766E+09 | 879.39 | 24.40 | 13.08 |
Report: ZoneCoolingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 98729654.64 | 2334.64 | 14-JAN-11:10 | 8.58 | 4.13 | 0.650105E+09 | 861.36 | 14-JAN-15:50 | 10.10 | 4.67 |
February | 0.347839E+09 | 4450.21 | 28-FEB-11:00 | 3.90 | 1.11 | 0.612154E+09 | 1131.07 | 27-FEB-15:00 | 3.90 | 1.11 |
March | 0.105743E+10 | 4524.16 | 24-MAR-14:50 | 3.72 | -0.5 | 0.724785E+09 | 1022.31 | 14-MAR-14:09 | 3.72 | -0.5 |
April | 0.117862E+10 | 4762.35 | 29-APR-13:00 | 3.30 | -2.3 | 0.751158E+09 | 1331.46 | 07-APR-14:39 | 3.30 | -2.3 |
May | 0.140037E+10 | 6276.16 | 22-MAY-08:50 | -0.1 | -0.6 | 0.933347E+09 | 1942.45 | 20-MAY-15:00 | -0.1 | -0.6 |
June | 0.164549E+10 | 16932.03 | 30-JUN-17:33 | 29.60 | 14.57 | 0.147293E+10 | 2246.83 | 24-JUN-12:20 | 29.60 | 14.57 |
July | 0.449206E+10 | 33883.02 | 19-JUL-17:08 | 30.77 | 16.46 | 0.174930E+10 | 2246.88 | 19-JUL-12:09 | 30.77 | 16.46 |
August | 0.388605E+10 | 33791.54 | 08-AUG-17:08 | 30.50 | 16.33 | 0.178920E+10 | 2246.84 | 08-AUG-12:09 | 30.50 | 16.33 |
September | 0.229464E+10 | 23034.63 | 03-SEP-15:35 | 33.67 | 16.05 | 0.124888E+10 | 2246.84 | 05-SEP-14:09 | 24.40 | 15.08 |
October | 0.165379E+10 | 6700.78 | 21-OCT-07:03 | -1.1 | -2.0 | 0.842088E+09 | 1581.06 | 18-OCT-15:39 | -1.1 | -2.0 |
November | 0.100352E+10 | 4790.43 | 10-NOV-11:20 | 3.17 | -0.6 | 0.664163E+09 | 1135.08 | 04-NOV-14:00 | 3.17 | -0.6 |
December | 0.281615E+09 | 3205.17 | 07-DEC-11:20 | 6.67 | 2.71 | 0.652002E+09 | 880.45 | 06-DEC-13:39 | 6.67 | 2.71 |
Annual Sum or Average | 0.193402E+11 | 0.120901E+11 | ||||||||
Minimum of Months | 98729654.64 | 2334.64 | -1.1 | -2.3 | 0.612154E+09 | 861.36 | -1.1 | -2.3 | ||
Maximum of Months | 0.449206E+10 | 33883.02 | 33.67 | 16.46 | 0.178920E+10 | 2246.88 | 30.77 | 16.46 |
Report: ZoneCoolingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 1.38 | -1.3 | 0.646720E+09 | 982.81 | 14-JAN-15:50 | 10.10 | 4.67 |
February | 0.00 | 0.00 | 01-FEB-00:02 | -12.4 | -13.9 | 0.636603E+09 | 1450.61 | 27-FEB-16:10 | 17.78 | 6.92 |
March | 0.00 | 0.00 | 01-MAR-00:10 | -3.0 | -4.1 | 0.778706E+09 | 1300.57 | 14-MAR-14:20 | 14.07 | 6.61 |
April | 0.00 | 0.00 | 01-APR-00:10 | 2.68 | 0.55 | 0.954394E+09 | 2008.26 | 07-APR-14:00 | 21.70 | 8.90 |
May | 0.00 | 0.00 | 01-MAY-00:03 | -1.1 | -3.0 | 0.133103E+10 | 3085.12 | 19-MAY-15:00 | 27.80 | 14.54 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 | 10.36 | 0.277188E+10 | 5313.36 | 29-JUN-15:20 | 31.83 | 14.57 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 | 13.32 | 0.412725E+10 | 7624.68 | 25-JUL-15:20 | 34.23 | 15.62 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 | 11.96 | 0.436470E+10 | 7816.29 | 05-AUG-15:00 | 35.60 | 17.65 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 18.43 | 11.59 | 0.252166E+10 | 5676.35 | 02-SEP-15:20 | 34.23 | 16.29 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 11.57 | 6.94 | 0.139679E+10 | 2554.13 | 18-OCT-15:20 | 24.80 | 11.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 4.98 | 1.54 | 0.822050E+09 | 1741.56 | 04-NOV-14:39 | 16.87 | 8.04 |
December | 0.00 | 0.00 | 01-DEC-00:03 | -2.1 | -4.2 | 0.666721E+09 | 1107.79 | 06-DEC-13:50 | 11.88 | 5.75 |
Annual Sum or Average | 0.00 | 0.210185E+11 | ||||||||
Minimum of Months | 0.00 | 0.00 | -12.4 | -13.9 | 0.636603E+09 | 982.81 | 10.10 | 4.67 | ||
Maximum of Months | 0.00 | 0.00 | 19.45 | 13.32 | 0.436470E+10 | 7816.29 | 35.60 | 17.65 |
Report: ZoneHeatingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.112502E+11 | 28858.41 | 26-JAN-06:42 | -22.2 |
February | 0.740524E+10 | 28427.65 | 04-FEB-06:42 | -19.9 |
March | 0.653827E+10 | 28411.07 | 06-MAR-07:01 | -19.7 |
April | 0.343173E+10 | 27636.85 | 28-APR-06:02 | -5.2 |
May | 0.244594E+10 | 27776.60 | 08-MAY-06:02 | -2.7 |
June | 0.246289E+09 | 16878.77 | 17-JUN-06:03 | 6.05 |
July | 77846660.98 | 1728.16 | 17-JUL-06:07 | 19.05 |
August | 0.120963E+09 | 8111.04 | 18-AUG-07:03 | 10.37 |
September | 0.684780E+09 | 27500.14 | 18-SEP-06:01 | 3.22 |
October | 0.191185E+10 | 27782.25 | 10-OCT-06:02 | -6.1 |
November | 0.483394E+10 | 28061.16 | 27-NOV-07:02 | -13.5 |
December | 0.821060E+10 | 28434.91 | 28-DEC-07:13 | -22.8 |
Annual Sum or Average | 0.471576E+11 | |||
Minimum of Months | 77846660.98 | 1728.16 | -22.8 | |
Maximum of Months | 0.112502E+11 | 28858.41 | 19.05 |
Report: ZoneHeatingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.391767E+11 | 72954.03 | 06-JAN-03:21 | -25.2 |
February | 0.236123E+11 | 72238.01 | 04-FEB-02:62 | -21.7 |
March | 0.188918E+11 | 72221.19 | 04-MAR-22:42 | -22.7 |
April | 0.721583E+10 | 70441.03 | 29-APR-04:23 | -7.8 |
May | 0.402232E+10 | 70399.44 | 08-MAY-04:23 | -2.5 |
June | 0.199036E+09 | 2478.76 | 20-JUN-16:20 | 29.40 |
July | 88819695.91 | 1406.45 | 10-JUL-15:00 | 27.80 |
August | 0.123869E+09 | 2150.94 | 24-AUG-17:00 | 29.40 |
September | 0.506692E+09 | 27041.90 | 20-SEP-05:02 | 3.30 |
October | 0.272132E+10 | 58930.09 | 10-OCT-04:53 | -6.1 |
November | 0.148399E+11 | 72234.52 | 27-NOV-04:02 | -15.8 |
December | 0.286021E+11 | 72871.22 | 31-DEC-06:41 | -27.9 |
Annual Sum or Average | 0.140001E+12 | |||
Minimum of Months | 88819695.91 | 1406.45 | -27.9 | |
Maximum of Months | 0.391767E+11 | 72954.03 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.145672E+12 | 132889.28 | 05-JAN-15:30 | -18.9 |
February | 0.774379E+11 | 100363.82 | 03-FEB-19:00 | -16.7 |
March | 0.533358E+11 | 103683.30 | 04-MAR-01:53 | -18.3 |
April | 0.676196E+10 | 48056.88 | 29-APR-04:52 | -7.8 |
May | 0.594909E+10 | 44877.65 | 08-MAY-06:00 | -2.8 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 18.43 |
October | 0.131688E+09 | 10456.69 | 11-OCT-05:57 | 0.00 |
November | 0.365868E+11 | 89114.29 | 27-NOV-05:00 | -15.6 |
December | 0.952339E+11 | 132139.49 | 31-DEC-03:00 | -24.4 |
Annual Sum or Average | 0.421109E+12 | |||
Minimum of Months | 0.00 | 0.00 | -24.4 | |
Maximum of Months | 0.145672E+12 | 132889.28 | 19.45 |
Report: ZoneElectricSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.133885E+10 | 1064.14 | 02-JAN-08:09 | 0.267964E+10 | 1912.50 | 02-JAN-08:09 |
February | 0.119058E+10 | 1050.65 | 02-FEB-08:09 | 0.243949E+10 | 1912.50 | 01-FEB-08:09 |
March | 0.132344E+10 | 1060.34 | 17-MAR-07:10 | 0.277107E+10 | 1912.50 | 01-MAR-08:09 |
April | 0.124750E+10 | 1047.93 | 01-APR-07:10 | 0.263007E+10 | 1912.50 | 01-APR-07:10 |
May | 0.127121E+10 | 1035.01 | 03-MAY-07:10 | 0.272536E+10 | 1912.50 | 01-MAY-07:10 |
June | 0.124214E+10 | 1003.50 | 16-JUN-07:10 | 0.267579E+10 | 1912.50 | 01-JUN-07:10 |
July | 0.124669E+10 | 1024.12 | 07-JUL-07:30 | 0.267964E+10 | 1912.50 | 01-JUL-07:10 |
August | 0.131002E+10 | 1030.54 | 17-AUG-07:10 | 0.277107E+10 | 1912.50 | 01-AUG-07:10 |
September | 0.125349E+10 | 1044.51 | 11-SEP-07:10 | 0.263007E+10 | 1912.50 | 01-SEP-07:10 |
October | 0.129428E+10 | 1064.14 | 30-OCT-07:10 | 0.267964E+10 | 1912.50 | 02-OCT-07:10 |
November | 0.127529E+10 | 1064.14 | 01-NOV-07:10 | 0.258435E+10 | 1912.50 | 01-NOV-07:10 |
December | 0.134188E+10 | 1064.14 | 01-DEC-16:40 | 0.267964E+10 | 1912.50 | 01-DEC-08:09 |
Annual Sum or Average | 0.153354E+11 | 0.319458E+11 | ||||
Minimum of Months | 0.119058E+10 | 1003.50 | 0.243949E+10 | 1912.50 | ||
Maximum of Months | 0.134188E+10 | 1064.14 | 0.277107E+10 | 1912.50 |
Report: ZoneElectricSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
January | 0.485298E+10 | 4354.33 | 02-JAN-09:09 | 0.00 | 0.00 |
February | 0.444173E+10 | 4354.33 | 01-FEB-09:09 | 0.00 | 0.00 |
March | 0.513145E+10 | 4354.33 | 01-MAR-09:09 | 0.00 | 0.00 |
April | 0.480872E+10 | 4354.33 | 01-APR-08:09 | 0.00 | 0.00 |
May | 0.499222E+10 | 4354.33 | 01-MAY-08:09 | 0.00 | 0.00 |
June | 0.494796E+10 | 4354.33 | 01-JUN-08:09 | 0.00 | 0.00 |
July | 0.485298E+10 | 4354.33 | 01-JUL-08:09 | 0.00 | 0.00 |
August | 0.513145E+10 | 4354.33 | 01-AUG-08:09 | 0.00 | 0.00 |
September | 0.480872E+10 | 4354.33 | 01-SEP-08:09 | 0.00 | 0.00 |
October | 0.485298E+10 | 4354.33 | 02-OCT-08:09 | 0.00 | 0.00 |
November | 0.466948E+10 | 4354.33 | 01-NOV-08:09 | 0.00 | 0.00 |
December | 0.485298E+10 | 4354.33 | 01-DEC-09:09 | 0.00 | 0.00 |
Annual Sum or Average | 0.583437E+11 | 0.00 | 0.00 | ||
Minimum of Months | 0.444173E+10 | 4354.33 | 0.00 | 0.00 | |
Maximum of Months | 0.513145E+10 | 4354.33 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.547598E+10 | 5080.05 | 02-JAN-09:09 | 0.885613E+10 | 8200.12 | 02-JAN-08:09 |
February | 0.496459E+10 | 5080.05 | 01-FEB-09:09 | 0.814764E+10 | 8200.12 | 01-FEB-08:09 |
March | 0.555464E+10 | 5080.05 | 06-MAR-09:09 | 0.957200E+10 | 8200.12 | 01-MAR-08:09 |
April | 0.516745E+10 | 4883.62 | 01-APR-08:09 | 0.885613E+10 | 8200.12 | 01-APR-07:10 |
May | 0.529993E+10 | 4687.19 | 02-MAY-08:09 | 0.921037E+10 | 8200.12 | 01-MAY-07:10 |
June | 0.523494E+10 | 4883.62 | 23-JUN-08:09 | 0.921037E+10 | 8200.12 | 01-JUN-07:10 |
July | 0.515820E+10 | 4883.62 | 03-JUL-08:09 | 0.885613E+10 | 8200.12 | 01-JUL-07:10 |
August | 0.551014E+10 | 4883.62 | 01-AUG-08:09 | 0.956462E+10 | 8200.12 | 01-AUG-07:10 |
September | 0.523832E+10 | 4883.62 | 01-SEP-08:09 | 0.884875E+10 | 8200.12 | 01-SEP-07:10 |
October | 0.539385E+10 | 5080.05 | 10-OCT-08:09 | 0.886351E+10 | 8200.12 | 02-OCT-07:10 |
November | 0.526892E+10 | 5080.05 | 02-NOV-08:09 | 0.850188E+10 | 8200.12 | 01-NOV-07:10 |
December | 0.552474E+10 | 5080.05 | 01-DEC-14:20 | 0.885613E+10 | 8200.12 | 01-DEC-08:09 |
Annual Sum or Average | 0.637917E+11 | 0.107344E+12 | ||||
Minimum of Months | 0.496459E+10 | 4687.19 | 0.814764E+10 | 8200.12 | ||
Maximum of Months | 0.555464E+10 | 5080.05 | 0.957200E+10 | 8200.12 |
Report: SpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.138726E+10 | 0.133885E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.679252E+10 |
February | 0.127628E+10 | 0.119058E+10 | 0.243949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.483775E+10 |
March | 0.149825E+10 | 0.132344E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.446720E+10 |
April | 0.138726E+10 | 0.124750E+10 | 0.263007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 895855.49 | 0.270849E+10 |
May | 0.144276E+10 | 0.127121E+10 | 0.272536E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20355869.44 | 0.257625E+10 |
June | 0.144276E+10 | 0.124214E+10 | 0.267579E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.139885E+09 | 0.143036E+10 |
July | 0.138726E+10 | 0.124669E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.331746E+09 | 0.890630E+09 |
August | 0.149825E+10 | 0.131002E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.251172E+09 | 0.121400E+10 |
September | 0.138726E+10 | 0.125349E+10 | 0.263007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 61393618.03 | 0.192843E+10 |
October | 0.138726E+10 | 0.129428E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4666040.68 | 0.253396E+10 |
November | 0.133177E+10 | 0.127529E+10 | 0.258435E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.385123E+10 |
December | 0.138726E+10 | 0.134188E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.527872E+10 |
Annual Sum or Average | 0.168137E+11 | 0.153354E+11 | 0.319458E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.810114E+09 | 0.385096E+11 |
Minimum of Months | 0.127628E+10 | 0.119058E+10 | 0.243949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.890630E+09 |
Maximum of Months | 0.149825E+10 | 0.134188E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.331746E+09 | 0.679252E+10 |
Report: SpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.326447E+10 | 0.485298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188196E+11 |
February | 0.300332E+10 | 0.444173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 145891.60 | 0.131380E+11 |
March | 0.352563E+10 | 0.513145E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116881E+11 |
April | 0.326447E+10 | 0.480872E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38803459.17 | 0.663104E+10 |
May | 0.339505E+10 | 0.499222E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.152093E+09 | 0.638129E+10 |
June | 0.339505E+10 | 0.494796E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.162858E+09 | 0.414499E+10 |
July | 0.326447E+10 | 0.485298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.407861E+09 | 0.330601E+10 |
August | 0.352563E+10 | 0.513145E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.363112E+09 | 0.386064E+10 |
September | 0.326447E+10 | 0.480872E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.203766E+09 | 0.543256E+10 |
October | 0.326447E+10 | 0.485298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67323753.02 | 0.607024E+10 |
November | 0.313390E+10 | 0.466948E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102442E+11 |
December | 0.326447E+10 | 0.485298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146906E+11 |
Annual Sum or Average | 0.395654E+11 | 0.583437E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.139596E+10 | 0.104407E+12 |
Minimum of Months | 0.300332E+10 | 0.444173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.330601E+10 |
Maximum of Months | 0.352563E+10 | 0.513145E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.407861E+09 | 0.188196E+11 |
Report: SpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.750829E+10 | 0.547598E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.790166E+11 |
February | 0.690763E+10 | 0.496459E+10 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.753233E+09 | 0.462010E+11 |
March | 0.810895E+10 | 0.555464E+10 | 0.957200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110301E+09 | 0.403991E+11 |
April | 0.750829E+10 | 0.516745E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.262226E+10 | 0.196456E+11 |
May | 0.780862E+10 | 0.529993E+10 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.440788E+10 | 0.194605E+11 |
June | 0.780862E+10 | 0.523494E+10 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.249366E+10 | 0.152215E+11 |
July | 0.750829E+10 | 0.515820E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.178305E+10 | 0.162076E+11 |
August | 0.810895E+10 | 0.551014E+10 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.952832E+09 | 0.219396E+11 |
September | 0.750829E+10 | 0.523832E+10 | 0.884875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.230112E+10 | 0.252274E+11 |
October | 0.750829E+10 | 0.539385E+10 | 0.886351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.263992E+10 | 0.218630E+11 |
November | 0.720796E+10 | 0.526892E+10 | 0.850188E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134289E+10 | 0.340292E+11 |
December | 0.750829E+10 | 0.552474E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.233161E+09 | 0.541307E+11 |
Annual Sum or Average | 0.910005E+11 | 0.637917E+11 | 0.107344E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.196403E+11 | 0.393342E+12 |
Minimum of Months | 0.690763E+10 | 0.496459E+10 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.152215E+11 |
Maximum of Months | 0.810895E+10 | 0.555464E+10 | 0.957200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.440788E+10 | 0.790166E+11 |
Report: PeakSpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1680.92 | 02-JAN-08:09 | 1064.14 | 02-JAN-08:09 | 1912.50 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 20434.15 | 05-JAN-17:10 |
February | 1680.92 | 01-FEB-08:09 | 1050.65 | 02-FEB-08:09 | 1912.50 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 17328.76 | 01-FEB-07:10 |
March | 1680.92 | 01-MAR-08:09 | 1060.34 | 17-MAR-07:10 | 1912.50 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 15789.27 | 06-MAR-07:10 |
April | 1680.92 | 01-APR-07:10 | 1047.93 | 01-APR-07:10 | 1912.50 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 86.54 | 16-APR-14:00 | 9296.32 | 28-APR-16:10 |
May | 1680.92 | 01-MAY-07:10 | 1035.01 | 03-MAY-07:10 | 1912.50 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1694.28 | 19-MAY-16:10 | 11243.73 | 22-MAY-06:10 |
June | 1680.92 | 01-JUN-07:10 | 1003.50 | 16-JUN-07:10 | 1912.50 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2794.12 | 29-JUN-16:10 | 6609.59 | 16-JUN-07:00 |
July | 1680.92 | 01-JUL-07:10 | 1024.12 | 07-JUL-07:30 | 1912.50 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4546.58 | 17-JUL-16:10 | 4974.77 | 05-JUL-06:05 |
August | 1680.92 | 01-AUG-07:10 | 1030.54 | 17-AUG-07:10 | 1912.50 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3161.29 | 10-AUG-17:00 | 6011.98 | 17-AUG-16:03 |
September | 1680.92 | 01-SEP-07:10 | 1044.51 | 11-SEP-07:10 | 1912.50 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1714.84 | 01-SEP-16:10 | 7901.10 | 18-SEP-16:10 |
October | 1680.92 | 02-OCT-07:10 | 1064.14 | 30-OCT-07:10 | 1912.50 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 283.93 | 15-OCT-14:00 | 10416.05 | 10-OCT-07:00 |
November | 1680.92 | 01-NOV-07:10 | 1064.14 | 01-NOV-07:10 | 1912.50 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 13959.01 | 27-NOV-07:10 |
December | 1680.92 | 01-DEC-08:09 | 1064.14 | 01-DEC-16:40 | 1912.50 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 17906.81 | 28-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1680.92 | 1003.50 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4974.77 | |||||
Maximum of Months | 1680.92 | 1064.14 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 4546.58 | 20434.15 |
Report: PeakSpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 3955.50 | 02-JAN-08:09 | 4354.33 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 34591.08 | 05-JAN-16:10 |
February | 3955.50 | 01-FEB-08:09 | 4354.33 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.08 | 27-FEB-15:00 | 18426.95 | 01-FEB-17:00 |
March | 3955.50 | 01-MAR-08:09 | 4354.33 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 16029.99 | 30-MAR-08:00 |
April | 3955.50 | 01-APR-07:10 | 4354.33 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1063.42 | 07-APR-15:10 | 11622.56 | 28-APR-16:00 |
May | 3955.50 | 01-MAY-07:10 | 4354.33 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3513.10 | 19-MAY-15:10 | 21550.18 | 22-MAY-06:03 |
June | 3955.50 | 01-JUN-07:10 | 4354.33 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4012.16 | 29-JUN-15:10 | 8218.04 | 14-JUN-08:00 |
July | 3955.50 | 01-JUL-07:10 | 4354.33 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4301.39 | 25-JUL-15:10 | 6358.69 | 08-JUL-07:00 |
August | 3955.50 | 01-AUG-07:10 | 4354.33 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3702.65 | 09-AUG-17:00 | 12492.87 | 17-AUG-15:05 |
September | 3955.50 | 01-SEP-07:10 | 4354.33 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3983.39 | 02-SEP-15:10 | 11015.48 | 12-SEP-03:00 |
October | 3955.50 | 02-OCT-07:10 | 4354.33 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2323.76 | 15-OCT-14:00 | 9517.28 | 31-OCT-16:00 |
November | 3955.50 | 01-NOV-07:10 | 4354.33 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 15775.39 | 28-NOV-08:00 |
December | 3955.50 | 01-DEC-08:09 | 4354.33 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 18016.18 | 31-DEC-03:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 3955.50 | 4354.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6358.69 | ||||
Maximum of Months | 3955.50 | 4354.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4301.39 | 34591.08 |
Report: PeakSpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 9097.65 | 02-JAN-08:09 | 5080.05 | 02-JAN-09:09 | 8200.12 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 138630.48 | 05-JAN-15:55 |
February | 9097.65 | 01-FEB-08:09 | 5080.05 | 01-FEB-09:09 | 8200.12 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 12917.38 | 27-FEB-13:10 | 77247.59 | 01-FEB-15:00 |
March | 9097.65 | 01-MAR-08:09 | 5080.05 | 06-MAR-09:09 | 8200.12 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 7699.13 | 14-MAR-12:10 | 62487.74 | 03-MAR-09:00 |
April | 9097.65 | 01-APR-07:10 | 4883.62 | 01-APR-08:09 | 8200.12 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25676.13 | 07-APR-12:10 | 43929.76 | 27-APR-11:00 |
May | 9097.65 | 01-MAY-07:10 | 4687.19 | 02-MAY-08:09 | 8200.12 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36188.37 | 19-MAY-16:00 | 67061.18 | 22-MAY-08:00 |
June | 9097.65 | 01-JUN-07:10 | 4883.62 | 23-JUN-08:09 | 8200.12 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19436.82 | 29-JUN-13:00 | 33539.63 | 14-JUN-08:00 |
July | 9097.65 | 01-JUL-07:10 | 4883.62 | 03-JUL-08:09 | 8200.12 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13679.36 | 17-JUL-16:00 | 27787.84 | 08-JUL-07:10 |
August | 9097.65 | 01-AUG-07:10 | 4883.62 | 01-AUG-08:09 | 8200.12 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13238.53 | 05-AUG-14:00 | 67447.62 | 17-AUG-12:03 |
September | 9097.65 | 01-SEP-07:10 | 4883.62 | 01-SEP-08:09 | 8200.12 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18803.74 | 23-SEP-14:00 | 52496.71 | 12-SEP-11:00 |
October | 9097.65 | 02-OCT-07:10 | 5080.05 | 10-OCT-08:09 | 8200.12 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24402.49 | 12-OCT-12:10 | 32387.59 | 03-OCT-09:00 |
November | 9097.65 | 01-NOV-07:10 | 5080.05 | 02-NOV-08:09 | 8200.12 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15696.20 | 17-NOV-14:00 | 57696.10 | 27-NOV-11:00 |
December | 9097.65 | 01-DEC-08:09 | 5080.05 | 01-DEC-14:20 | 8200.12 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 11632.85 | 10-DEC-01:55 | 100445.00 | 27-DEC-14:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 9097.65 | 4687.19 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27787.84 | |||||
Maximum of Months | 9097.65 | 5080.05 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 36188.37 | 138630.48 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 763.04 | 14-JAN-08:07 | 5042.77 | 3192.43 | 5737.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 989.31 |
February | 135.70 | 25-FEB-08:07 | 5042.77 | 3074.15 | 5737.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1709.57 |
March | 668.45 | 25-MAR-07:07 | 5042.77 | 3110.93 | 5737.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 536.79 |
April | 1025.05 | 13-APR-07:07 | 5042.77 | 3014.73 | 5737.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 882.33 |
May | 3464.16 | 19-MAY-16:00 | 1680.92 | 856.64 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 825.04 | 0.00 |
June | 18326.80 | 24-JUN-07:02 | 8404.61 | 4685.20 | 9562.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 331.33 |
July | 22007.06 | 29-JUL-07:02 | 8404.61 | 4796.81 | 9562.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 442.61 |
August | 22019.68 | 26-AUG-07:02 | 8404.61 | 4858.83 | 9562.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 333.53 |
September | 23371.23 | 09-SEP-07:02 | 8404.61 | 4993.19 | 9562.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 601.29 |
October | 1673.32 | 18-OCT-16:00 | 1680.92 | 874.57 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 70.09 | 0.00 |
November | 1432.28 | 18-NOV-08:07 | 5042.77 | 3121.28 | 5737.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 677.65 |
December | 1408.13 | 09-DEC-08:07 | 5042.77 | 3186.95 | 5737.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 135.70 | 1680.92 | 856.64 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 23371.23 | 8404.61 | 4993.19 | 9562.50 | 0.00 | 0.00 | 0.00 | 0.00 | 825.04 | 1709.57 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2334.64 | 14-JAN-11:10 | 3955.50 | 4354.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1551.63 |
February | 4450.21 | 28-FEB-11:00 | 3955.50 | 4354.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1200.15 |
March | 4524.16 | 24-MAR-14:50 | 3955.50 | 4354.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 981.31 |
April | 4762.35 | 29-APR-13:00 | 3955.50 | 4354.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1469.51 |
May | 6276.16 | 22-MAY-08:50 | 3955.50 | 4354.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6323.64 |
June | 16932.03 | 30-JUN-17:33 | 0.00 | 1536.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 645.54 | 0.00 |
July | 33883.02 | 19-JUL-17:08 | 0.00 | 2561.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1868.45 | 0.00 |
August | 33791.54 | 08-AUG-17:08 | 0.00 | 2561.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 484.87 | 0.00 |
September | 23034.63 | 03-SEP-15:35 | 0.00 | 1024.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2806.50 | 0.00 |
October | 6700.78 | 21-OCT-07:03 | 11866.50 | 11526.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5603.63 |
November | 4790.43 | 10-NOV-11:20 | 3955.50 | 4354.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1281.27 |
December | 3205.17 | 07-DEC-11:20 | 3955.50 | 4354.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1298.13 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 2334.64 | 0.00 | 1024.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 33883.02 | 11866.50 | 11526.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2806.50 | 6323.64 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:03 | 0.00 | 1792.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5743.14 |
February | 0.00 | 01-FEB-00:02 | 0.00 | 2988.26 | 10250.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44680.21 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 597.65 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9192.97 |
April | 0.00 | 01-APR-00:10 | 0.00 | 597.65 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11793.68 |
May | 0.00 | 01-MAY-00:03 | 0.00 | 1792.96 | 6150.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12204.61 |
June | 0.00 | 01-JUN-00:10 | 0.00 | 597.65 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1200.28 |
July | 0.00 | 01-JUL-00:10 | 0.00 | 597.65 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5611.27 |
August | 0.00 | 01-AUG-00:10 | 0.00 | 597.65 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6033.33 |
September | 0.00 | 01-SEP-00:10 | 0.00 | 597.65 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6276.74 |
October | 0.00 | 01-OCT-00:10 | 0.00 | 597.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14407.62 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 597.65 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14476.76 |
December | 0.00 | 01-DEC-00:03 | 0.00 | 2390.61 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34164.16 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 597.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1200.28 | |
Maximum of Months | 0.00 | 0.00 | 2988.26 | 10250.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44680.21 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
January | 0.379487E+11 | 29987.73 | 05-JAN-16:49 | 0.264598E+12 | 271217.70 | 05-JAN-17:10 |
February | 0.333557E+11 | 25523.30 | 01-FEB-15:20 | 0.147876E+12 | 193135.26 | 01-FEB-17:00 |
March | 0.366364E+11 | 25042.54 | 06-MAR-09:20 | 0.107951E+12 | 180376.36 | 06-MAR-03:39 |
April | 0.325754E+11 | 24591.78 | 20-APR-08:20 | 0.252606E+11 | 96703.58 | 29-APR-05:10 |
May | 0.326517E+11 | 24682.99 | 20-MAY-14:00 | 0.167965E+11 | 99293.29 | 08-MAY-06:10 |
June | 0.321562E+11 | 28405.69 | 29-JUN-14:00 | 0.144939E+09 | 8977.54 | 16-JUN-06:10 |
July | 0.335620E+11 | 32758.85 | 25-JUL-14:00 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 0.357716E+11 | 33291.51 | 10-AUG-14:00 | 16810531.93 | 4382.21 | 18-AUG-07:10 |
September | 0.331932E+11 | 29704.13 | 02-SEP-14:00 | 0.125008E+10 | 26850.82 | 20-SEP-06:10 |
October | 0.343673E+11 | 28934.26 | 31-OCT-07:10 | 0.701590E+10 | 51477.04 | 11-OCT-06:10 |
November | 0.349508E+11 | 29500.12 | 27-NOV-16:49 | 0.770330E+11 | 167755.60 | 27-NOV-04:10 |
December | 0.377998E+11 | 29724.83 | 29-DEC-16:40 | 0.179888E+12 | 225314.19 | 31-DEC-02:49 |
Annual Sum or Average | 0.414969E+12 | 0.827830E+12 | ||||
Minimum of Months | 0.321562E+11 | 24591.78 | 0.00 | 0.00 | ||
Maximum of Months | 0.379487E+11 | 33291.51 | 0.264598E+12 | 271217.70 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.116678E+11 | 0.819918E+10 | 0.115358E+11 | 0.00 | 0.422393E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.232204E+10 | 0.00 |
February | 0.105969E+11 | 0.668548E+10 | 0.105871E+11 | 0.00 | 0.335883E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.212738E+10 | 0.00 |
March | 0.120095E+11 | 0.639322E+10 | 0.123431E+11 | 0.00 | 0.349149E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.239912E+10 | 0.00 |
April | 0.112237E+11 | 0.516802E+10 | 0.114862E+11 | 0.00 | 0.245103E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.224646E+10 | 0.00 |
May | 0.115634E+11 | 0.446957E+10 | 0.119357E+11 | 0.00 | 0.235863E+10 | 0.00 | 0.00 | 53186513.69 | 0.00 | 0.00 | 0.00 | 0.227122E+10 | 0.00 |
June | 0.114250E+11 | 0.391264E+10 | 0.118862E+11 | 0.00 | 0.211651E+10 | 0.00 | 0.00 | 0.652548E+09 | 0.00 | 0.00 | 0.00 | 0.216330E+10 | 0.00 |
July | 0.112579E+11 | 0.421167E+10 | 0.115358E+11 | 0.00 | 0.217927E+10 | 0.00 | 0.00 | 0.224493E+10 | 0.00 | 0.00 | 0.00 | 0.213251E+10 | 0.00 |
August | 0.119516E+11 | 0.493328E+10 | 0.123357E+11 | 0.00 | 0.263288E+10 | 0.00 | 0.00 | 0.174549E+10 | 0.00 | 0.00 | 0.00 | 0.217261E+10 | 0.00 |
September | 0.113005E+11 | 0.574145E+10 | 0.114788E+11 | 0.00 | 0.205704E+10 | 0.00 | 0.00 | 0.530025E+09 | 0.00 | 0.00 | 0.00 | 0.208529E+10 | 0.00 |
October | 0.115411E+11 | 0.697983E+10 | 0.115432E+11 | 0.00 | 0.212385E+10 | 0.00 | 0.00 | 6782259.44 | 0.00 | 0.00 | 0.00 | 0.217254E+10 | 0.00 |
November | 0.112137E+11 | 0.767594E+10 | 0.110862E+11 | 0.00 | 0.282736E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.214755E+10 | 0.00 |
December | 0.117196E+11 | 0.845953E+10 | 0.115358E+11 | 0.00 | 0.380490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.227995E+10 | 0.00 |
Annual Sum or Average | 0.137471E+12 | 0.728298E+11 | 0.139290E+12 | 0.00 | 0.336257E+11 | 0.00 | 0.00 | 0.523297E+10 | 0.00 | 0.00 | 0.00 | 0.265200E+11 | 0.00 |
Minimum of Months | 0.105969E+11 | 0.391264E+10 | 0.105871E+11 | 0.00 | 0.205704E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.208529E+10 | 0.00 |
Maximum of Months | 0.120095E+11 | 0.845953E+10 | 0.123431E+11 | 0.00 | 0.422393E+10 | 0.00 | 0.00 | 0.224493E+10 | 0.00 | 0.00 | 0.00 | 0.239912E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
January | 0.00 | 0.00 | 0.264598E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.147876E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.107951E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.252606E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.167965E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.144939E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 16810531.93 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.125008E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.701590E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.770330E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.179888E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.827830E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.264598E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 10485.81 | 19-JAN-09:09 | 5492.60 | 01-JAN-06:10 | 10112.62 | 02-JAN-08:09 | 0.00 | 3395.24 | 05-JAN-16:10 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 10464.48 | 01-FEB-09:09 | 5492.60 | 01-FEB-06:10 | 10112.62 | 01-FEB-08:09 | 0.00 | 3111.58 | 04-FEB-08:09 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 10465.24 | 16-MAR-08:09 | 5492.60 | 01-MAR-06:10 | 10112.62 | 01-MAR-08:09 | 0.00 | 3036.86 | 06-MAR-08:09 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 10270.15 | 01-APR-08:09 | 5492.60 | 01-APR-05:10 | 10112.62 | 01-APR-07:10 | 0.00 | 2743.59 | 29-APR-07:10 | 0.00 | 0.00 | 01-APR-00:10 |
May | 10049.31 | 08-MAY-08:09 | 5492.60 | 01-MAY-05:10 | 10112.62 | 01-MAY-07:10 | 0.00 | 2766.75 | 08-MAY-07:00 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 10229.20 | 23-JUN-08:09 | 5492.60 | 01-JUN-20:10 | 10112.62 | 01-JUN-07:10 | 0.00 | 2055.14 | 01-JUN-06:10 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 10209.37 | 03-JUL-08:09 | 5492.60 | 01-JUL-20:30 | 10112.62 | 01-JUL-07:10 | 0.00 | 4411.05 | 25-JUL-15:09 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 10242.15 | 04-AUG-08:09 | 5492.60 | 01-AUG-19:00 | 10112.62 | 01-AUG-07:10 | 0.00 | 4497.77 | 10-AUG-15:09 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 10253.61 | 11-SEP-08:09 | 5492.60 | 01-SEP-05:10 | 10112.62 | 01-SEP-07:10 | 0.00 | 2184.52 | 20-SEP-07:10 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 10468.80 | 28-OCT-08:09 | 5492.60 | 01-OCT-05:10 | 10112.62 | 02-OCT-07:10 | 0.00 | 2677.28 | 11-OCT-07:10 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 10464.52 | 03-NOV-08:09 | 5492.60 | 01-NOV-05:10 | 10112.62 | 01-NOV-07:10 | 0.00 | 2972.64 | 27-NOV-08:09 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 10473.47 | 26-DEC-09:09 | 5492.60 | 01-DEC-06:10 | 10112.62 | 01-DEC-08:09 | 0.00 | 3189.34 | 28-DEC-08:09 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||||
Minimum of Months | 10049.31 | 5492.60 | 10112.62 | 0.00 | 2055.14 | 0.00 | 0.00 | |||||
Maximum of Months | 10485.81 | 5492.60 | 10112.62 | 0.00 | 4497.77 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 2821.09 | 31-JAN-12:20 | 0.00 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 2841.61 | 18-FEB-12:00 | 0.00 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 2833.00 | 02-MAR-12:09 | 0.00 |
April | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 2738.12 | 01-APR-11:50 | 0.00 |
May | 1168.85 | 20-MAY-15:00 | 0.00 | 0.00 | 0.00 | 2545.77 | 01-MAY-11:39 | 0.00 |
June | 5362.13 | 29-JUN-15:09 | 0.00 | 0.00 | 0.00 | 2277.60 | 01-JUN-11:30 | 0.00 |
July | 9527.25 | 17-JUL-15:00 | 0.00 | 0.00 | 0.00 | 1958.11 | 08-JUL-11:00 | 0.00 |
August | 7724.34 | 10-AUG-15:09 | 0.00 | 0.00 | 0.00 | 1814.73 | 05-AUG-11:00 | 0.00 |
September | 6499.54 | 02-SEP-15:09 | 0.00 | 0.00 | 0.00 | 1865.47 | 16-SEP-11:00 | 0.00 |
October | 633.02 | 18-OCT-15:00 | 0.00 | 0.00 | 0.00 | 2210.81 | 31-OCT-11:00 | 0.00 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 2468.12 | 29-NOV-12:20 | 0.00 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 2690.44 | 30-DEC-12:09 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1814.73 | 0.00 | ||
Maximum of Months | 9527.25 | 0.00 | 0.00 | 0.00 | 2841.61 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 29987.73 | 05-JAN-16:49 | 9388.60 | 10112.62 | 5492.60 | 0.00 | 3368.85 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 25523.30 | 01-FEB-15:20 | 10361.36 | 10112.62 | 0.00 | 0.00 | 2706.06 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 25042.54 | 06-MAR-09:20 | 10456.37 | 10112.62 | 0.00 | 0.00 | 2763.03 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 24591.78 | 20-APR-08:20 | 10253.09 | 10112.62 | 0.00 | 0.00 | 2526.30 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 24682.99 | 20-MAY-14:00 | 9701.73 | 10112.62 | 0.00 | 0.00 | 2055.14 | 0.00 | 0.00 | 1003.94 | 0.00 |
June | 28405.69 | 29-JUN-14:00 | 9701.73 | 10112.62 | 0.00 | 0.00 | 2055.14 | 0.00 | 0.00 | 4754.56 | 0.00 |
July | 32758.85 | 25-JUL-14:00 | 9701.73 | 10112.62 | 0.00 | 0.00 | 4360.43 | 0.00 | 0.00 | 6813.56 | 0.00 |
August | 33291.51 | 10-AUG-14:00 | 9701.73 | 10112.62 | 0.00 | 0.00 | 4400.21 | 0.00 | 0.00 | 7310.06 | 0.00 |
September | 29704.13 | 02-SEP-14:00 | 9898.16 | 10112.62 | 0.00 | 0.00 | 2055.14 | 0.00 | 0.00 | 5871.11 | 0.00 |
October | 28934.26 | 31-OCT-07:10 | 9388.60 | 10112.62 | 5492.60 | 0.00 | 2294.60 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 29500.12 | 27-NOV-16:49 | 9388.60 | 10112.62 | 5492.60 | 0.00 | 2888.15 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 29724.83 | 29-DEC-16:40 | 9388.60 | 10112.62 | 5492.60 | 0.00 | 3107.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 24591.78 | 9388.60 | 10112.62 | 0.00 | 0.00 | 2055.14 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 33291.51 | 10456.37 | 10112.62 | 5492.60 | 0.00 | 4400.21 | 0.00 | 0.00 | 7310.06 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | |
January | 0.00 | 0.00 | 271217.70 | 05-JAN-17:10 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 193135.26 | 01-FEB-17:00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 180376.36 | 06-MAR-03:39 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 96703.58 | 29-APR-05:10 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 99293.29 | 08-MAY-06:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 8977.54 | 16-JUN-06:10 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 4382.21 | 18-AUG-07:10 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 26850.82 | 20-SEP-06:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 51477.04 | 11-OCT-06:10 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 167755.60 | 27-NOV-04:10 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 225314.19 | 31-DEC-02:49 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 271217.70 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 45.17 | 15.32 | 9.00 | 15.66 | 0.00 | 15.66 | 0.00 | 15.66 |
February | 19.50 | 15.41 | 4.83 | 15.67 | 0.00 | 15.67 | 0.00 | 15.67 |
March | 13.83 | 15.58 | 5.50 | 15.88 | 0.00 | 15.88 | 0.00 | 15.88 |
April | 3.33 | 16.75 | 2.83 | 16.89 | 0.00 | 16.89 | 0.00 | 16.89 |
May | 1.83 | 16.78 | 1.67 | 16.87 | 0.00 | 16.87 | 0.00 | 16.87 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.83 | 16.61 | 0.67 | 16.78 | 0.00 | 16.78 | 0.00 | 16.78 |
November | 8.33 | 15.77 | 3.33 | 16.14 | 0.00 | 16.14 | 0.00 | 16.14 |
December | 16.83 | 15.50 | 5.17 | 15.81 | 0.00 | 15.81 | 0.00 | 15.81 |
Annual Sum or Average | 109.67 | 15.51 | 33.00 | 15.85 | 0.00 | 15.85 | 0.00 | 15.85 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 45.17 | 16.78 | 9.00 | 16.89 | 0.00 | 16.89 | 0.00 | 16.89 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 113.33 | 14.19 | 4.67 | 14.19 | 0.00 | 14.19 | 0.00 | 14.19 |
February | 89.17 | 14.44 | 4.50 | 14.44 | 0.00 | 14.44 | 0.00 | 14.44 |
March | 87.33 | 14.62 | 5.83 | 14.62 | 0.00 | 14.62 | 0.00 | 14.62 |
April | 30.50 | 14.85 | 2.50 | 14.85 | 0.00 | 14.85 | 0.00 | 14.85 |
May | 18.67 | 14.78 | 1.67 | 14.79 | 0.00 | 14.79 | 0.00 | 14.79 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 27.29 | 0.00 | 27.29 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 1.50 | 27.33 | 0.00 | 27.33 |
September | 0.50 | 14.98 | 0.00 | 14.98 | 0.67 | 22.01 | 0.00 | 22.01 |
October | 10.33 | 14.86 | 0.83 | 14.85 | 0.00 | 14.85 | 0.00 | 14.85 |
November | 60.17 | 14.59 | 3.50 | 14.59 | 0.00 | 14.59 | 0.00 | 14.59 |
December | 110.17 | 14.42 | 4.50 | 14.42 | 0.00 | 14.42 | 0.00 | 14.42 |
Annual Sum or Average | 520.17 | 14.48 | 28.00 | 14.48 | 4.33 | 14.58 | 0.00 | 14.58 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 113.33 | 14.98 | 5.83 | 14.98 | 2.17 | 27.33 | 0.00 | 27.33 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 5.67 | 8.43 | 3.00 | 8.36 | 0.00 | 8.36 | 0.00 | 8.36 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 5.67 | 8.43 | 3.00 | 8.36 | 0.00 | 8.36 | 0.00 | 8.36 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 5.67 | 8.43 | 3.00 | 8.36 | 0.00 | 8.36 | 0.00 | 8.36 |
Report: ComfortReportSimple55Monthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 300.00 | 20.68 | 300.00 | 20.68 | 300.00 | 20.68 |
February | 276.00 | 20.72 | 276.00 | 20.72 | 276.00 | 20.72 |
March | 324.00 | 20.71 | 324.00 | 20.71 | 324.00 | 20.71 |
April | 300.00 | 20.89 | 277.33 | 20.82 | 277.33 | 20.80 |
May | 312.00 | 21.49 | 211.50 | 21.15 | 211.50 | 21.01 |
June | 225.00 | 22.98 | 52.50 | 22.83 | 25.17 | 22.62 |
July | 55.67 | 23.59 | 163.17 | 24.03 | 0.00 | 24.03 |
August | 130.50 | 23.40 | 97.50 | 23.71 | 2.00 | 23.68 |
September | 226.50 | 22.33 | 123.50 | 22.20 | 78.17 | 21.93 |
October | 300.00 | 21.34 | 209.33 | 21.06 | 209.33 | 20.95 |
November | 288.00 | 20.75 | 283.67 | 20.74 | 283.67 | 20.74 |
December | 300.00 | 20.71 | 300.00 | 20.71 | 300.00 | 20.71 |
Annual Sum or Average | 3037.67 | 21.33 | 2618.50 | 21.24 | 2287.17 | 21.08 |
Minimum of Months | 55.67 | 20.68 | 52.50 | 20.68 | 0.00 | 20.68 |
Maximum of Months | 324.00 | 23.59 | 324.00 | 24.03 | 324.00 | 24.03 |
Report: ComfortReportSimple55Monthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 300.00 | 15.55 | 300.00 | 15.55 | 300.00 | 15.55 |
February | 276.00 | 15.70 | 276.00 | 15.70 | 276.00 | 15.70 |
March | 324.00 | 15.76 | 324.00 | 15.76 | 324.00 | 15.76 |
April | 300.00 | 16.61 | 300.00 | 16.61 | 300.00 | 16.61 |
May | 312.00 | 18.04 | 265.33 | 17.68 | 265.33 | 17.55 |
June | 216.00 | 21.53 | 144.67 | 22.22 | 63.00 | 21.80 |
July | 73.33 | 24.51 | 236.83 | 25.89 | 30.67 | 25.96 |
August | 117.17 | 23.11 | 199.67 | 25.01 | 19.50 | 25.01 |
September | 236.83 | 20.18 | 204.00 | 20.52 | 147.17 | 20.12 |
October | 300.00 | 17.54 | 293.00 | 17.49 | 293.00 | 17.48 |
November | 288.00 | 15.98 | 288.00 | 15.98 | 288.00 | 15.98 |
December | 300.00 | 15.57 | 300.00 | 15.57 | 300.00 | 15.57 |
Annual Sum or Average | 3043.33 | 17.48 | 3131.50 | 17.86 | 2606.67 | 17.50 |
Minimum of Months | 73.33 | 15.55 | 144.67 | 15.55 | 19.50 | 15.55 |
Maximum of Months | 324.00 | 24.51 | 324.00 | 25.89 | 324.00 | 25.96 |
Report: ComfortReportSimple55Monthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 300.00 | 10.01 | 300.00 | 10.01 | 300.00 | 10.01 |
February | 276.00 | 10.32 | 276.00 | 10.32 | 276.00 | 10.32 |
March | 324.00 | 10.53 | 324.00 | 10.53 | 324.00 | 10.53 |
April | 300.00 | 12.04 | 300.00 | 12.04 | 300.00 | 12.04 |
May | 312.00 | 13.90 | 312.00 | 13.90 | 312.00 | 13.90 |
June | 281.17 | 20.06 | 193.67 | 19.75 | 178.50 | 19.46 |
July | 165.33 | 26.04 | 196.17 | 26.73 | 94.00 | 27.11 |
August | 208.33 | 25.59 | 177.33 | 26.55 | 92.67 | 27.07 |
September | 238.67 | 18.40 | 250.33 | 18.88 | 200.67 | 18.54 |
October | 300.00 | 14.76 | 300.00 | 14.76 | 300.00 | 14.76 |
November | 288.00 | 11.43 | 288.00 | 11.43 | 288.00 | 11.43 |
December | 300.00 | 10.15 | 300.00 | 10.15 | 300.00 | 10.15 |
Annual Sum or Average | 3293.50 | 14.47 | 3217.50 | 14.51 | 2965.83 | 14.22 |
Minimum of Months | 165.33 | 10.01 | 177.33 | 10.01 | 92.67 | 10.01 |
Maximum of Months | 324.00 | 26.04 | 324.00 | 26.73 | 324.00 | 27.11 |
Report: OccupantComfortDataSummaryMonthly
For: OFFICE PEOPLE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: ZONE2 FINE STORAGEPEOPLE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: ZONE3 BULK STORAGEPEOPLE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
May | 0.241121E+09 | 53186513.69 | 29.58 | 0.240735E+09 | 385429.74 | 0.00 | 0.59 | 20-MAY-16:00 | 0.00 | 01-MAY-00:03 | 5114.45 | 19-MAY-16:00 | 5114.45 | 19-MAY-16:00 | 41.94 | 19-MAY-13:40 | 1168.85 | 20-MAY-16:00 | 0.00 | 01-MAY-00:03 |
June | 0.206182E+10 | 0.443928E+09 | 127.16 | 0.198183E+10 | 79986866.97 | 0.00 | 1.00 | 23-JUN-07:03 | 0.00 | 01-JUN-00:10 | 17562.48 | 24-JUN-07:02 | 13578.47 | 24-JUN-07:02 | 3984.01 | 24-JUN-07:02 | 3538.31 | 24-JUN-07:02 | 0.00 | 01-JUN-00:10 |
July | 0.487971E+10 | 0.105409E+10 | 214.51 | 0.473809E+10 | 0.141619E+09 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:10 | 19446.42 | 19-JUL-07:02 | 17885.87 | 18-JUL-07:02 | 6288.82 | 19-JUL-07:02 | 3882.75 | 19-JUL-07:02 | 0.00 | 01-JUL-00:10 |
August | 0.392756E+10 | 0.851051E+09 | 200.07 | 0.390082E+10 | 26737685.20 | 0.00 | 1.00 | 04-AUG-15:50 | 0.00 | 01-AUG-00:10 | 17591.07 | 09-AUG-07:02 | 17295.33 | 10-AUG-07:02 | 1300.39 | 09-AUG-07:02 | 3544.02 | 09-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.133873E+10 | 0.283374E+09 | 82.58 | 0.123469E+10 | 0.104042E+09 | 0.00 | 1.00 | 02-SEP-07:02 | 0.00 | 01-SEP-00:10 | 17334.02 | 05-SEP-07:02 | 16837.09 | 09-SEP-07:02 | 5119.89 | 07-SEP-14:50 | 3492.18 | 05-SEP-07:02 | 0.00 | 01-SEP-00:10 |
October | 31077022.16 | 6782259.44 | 7.50 | 31077022.16 | 0.00 | 0.00 | 0.35 | 18-OCT-16:00 | 0.00 | 01-OCT-00:10 | 2951.66 | 18-OCT-16:00 | 2951.66 | 18-OCT-16:00 | 0.00 | 18-OCT-15:00 | 633.02 | 18-OCT-16:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.124800E+11 | 0.269241E+10 | 661.41 | 0.121272E+11 | 0.352771E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.487971E+10 | 0.105409E+10 | 214.51 | 0.473809E+10 | 0.141619E+09 | 0.00 | 1.00 | 0.00 | 19446.42 | 17885.87 | 6288.82 | 3882.75 | 0.00 |
Report: DXReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 01-MAY-00:03 | 0.00 | 01-MAY-00:03 | 0.00 | 01-MAY-00:03 | 0.00 | 01-MAY-00:03 | 0.00 | 01-MAY-00:03 | 0.00 | 01-MAY-00:03 |
June | 0.770959E+09 | 0.208620E+09 | 38.97 | 0.762964E+09 | 7994619.56 | 0.00 | 1.00 | 30-JUN-17:33 | 0.00 | 01-JUN-00:10 | 18414.00 | 30-JUN-17:33 | 18414.00 | 30-JUN-17:33 | 438.07 | 22-JUN-15:00 | 4518.54 | 30-JUN-17:33 | 0.00 | 01-JUN-00:10 |
July | 0.451414E+10 | 0.119084E+10 | 150.78 | 0.443085E+10 | 83294198.40 | 0.00 | 1.00 | 02-JUL-14:45 | 0.00 | 01-JUL-00:10 | 39468.89 | 16-JUL-11:05 | 37440.04 | 19-JUL-17:45 | 5208.88 | 16-JUL-11:05 | 9585.25 | 17-JUL-17:08 | 0.00 | 01-JUL-00:10 |
August | 0.337343E+10 | 0.894444E+09 | 107.73 | 0.336490E+10 | 8533462.22 | 0.00 | 1.00 | 04-AUG-17:33 | 0.00 | 01-AUG-00:10 | 37117.76 | 08-AUG-19:55 | 37117.76 | 08-AUG-19:55 | 774.12 | 08-AUG-12:00 | 9119.52 | 07-AUG-17:08 | 0.00 | 01-AUG-00:10 |
September | 0.929638E+09 | 0.246651E+09 | 39.27 | 0.866347E+09 | 63290730.61 | 0.00 | 1.00 | 02-SEP-17:12 | 0.00 | 01-SEP-00:10 | 25289.15 | 03-SEP-15:35 | 25289.15 | 03-SEP-15:35 | 3352.09 | 07-SEP-15:40 | 6806.77 | 03-SEP-15:35 | 0.00 | 01-SEP-00:10 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.958817E+10 | 0.254055E+10 | 336.74 | 0.942506E+10 | 0.163113E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.451414E+10 | 0.119084E+10 | 150.78 | 0.443085E+10 | 83294198.40 | 0.00 | 1.00 | 0.00 | 39468.89 | 37440.04 | 5208.88 | 9585.25 | 0.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 60.70 | 24.66 | 36.04 | 35.22 | 200.95 | 0.00 | 0.00 | 0.00 |
February | 102.84 | 50.61 | 52.23 | 89.74 | 138.00 | 0.00 | 0.00 | 0.00 |
March | 132.02 | 48.49 | 83.53 | 121.19 | 109.13 | 0.00 | 0.00 | 0.00 |
April | 172.04 | 76.00 | 96.04 | 188.83 | 70.69 | 0.00 | 0.00 | 0.00 |
May | 212.84 | 97.10 | 115.74 | 249.37 | 55.96 | 0.00 | 0.00 | 0.00 |
June | 231.39 | 106.25 | 125.14 | 288.07 | 45.41 | 0.00 | 0.00 | 0.00 |
July | 237.28 | 119.95 | 117.33 | 309.91 | 46.09 | 0.00 | 0.00 | 0.00 |
August | 201.05 | 98.41 | 102.65 | 256.81 | 48.70 | 0.00 | 0.00 | 0.00 |
September | 161.88 | 81.79 | 80.08 | 195.62 | 60.36 | 0.00 | 0.00 | 0.00 |
October | 115.93 | 57.62 | 58.30 | 125.58 | 77.96 | 0.00 | 0.00 | 0.00 |
November | 81.92 | 40.64 | 41.27 | 73.73 | 111.47 | 0.00 | 0.00 | 0.00 |
December | 54.95 | 23.15 | 31.80 | 34.58 | 166.47 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 147.27 | 68.79 | 78.48 | 164.42 | 94.15 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 54.95 | 23.15 | 31.80 | 34.58 | 45.41 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 237.28 | 119.95 | 125.14 | 309.91 | 200.95 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 60.70 | 24.66 | 36.04 | 35.22 | 200.95 | 0.00 | 0.00 | 0.00 |
February | 102.84 | 50.61 | 52.23 | 89.74 | 138.00 | 0.00 | 0.00 | 0.00 |
March | 132.02 | 48.49 | 83.53 | 121.19 | 109.13 | 0.00 | 0.00 | 0.00 |
April | 172.04 | 76.00 | 96.04 | 188.83 | 70.69 | 0.00 | 0.00 | 0.00 |
May | 212.84 | 97.10 | 115.74 | 249.37 | 55.96 | 0.00 | 0.00 | 0.00 |
June | 231.39 | 106.25 | 125.14 | 288.07 | 45.41 | 0.00 | 0.00 | 0.00 |
July | 237.28 | 119.95 | 117.33 | 309.91 | 46.09 | 0.00 | 0.00 | 0.00 |
August | 201.05 | 98.41 | 102.65 | 256.81 | 48.70 | 0.00 | 0.00 | 0.00 |
September | 161.88 | 81.79 | 80.08 | 195.62 | 60.36 | 0.00 | 0.00 | 0.00 |
October | 115.93 | 57.62 | 58.30 | 125.58 | 77.96 | 0.00 | 0.00 | 0.00 |
November | 81.92 | 40.64 | 41.27 | 73.73 | 111.47 | 0.00 | 0.00 | 0.00 |
December | 54.95 | 23.15 | 31.80 | 34.58 | 166.47 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 147.27 | 68.79 | 78.48 | 164.42 | 94.15 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 54.95 | 23.15 | 31.80 | 34.58 | 45.41 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 237.28 | 119.95 | 125.14 | 309.91 | 200.95 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 16.92 | 0.00 | 16.92 | 1.22 | 123.66 | 0.00 | 0.00 | 0.00 |
February | 23.89 | 0.00 | 23.89 | 7.11 | 86.25 | 0.00 | 0.00 | 0.00 |
March | 38.81 | 0.00 | 38.81 | 19.85 | 65.34 | 0.00 | 0.00 | 0.00 |
April | 44.38 | 0.34 | 44.05 | 33.07 | 40.92 | 0.00 | 0.00 | 0.00 |
May | 58.06 | 3.40 | 54.67 | 54.76 | 31.31 | 0.00 | 0.00 | 0.00 |
June | 67.58 | 7.72 | 59.86 | 74.87 | 23.98 | 0.00 | 0.00 | 0.00 |
July | 61.73 | 5.71 | 56.02 | 74.46 | 24.81 | 0.00 | 0.00 | 0.00 |
August | 50.05 | 1.81 | 48.24 | 55.58 | 27.00 | 0.00 | 0.00 | 0.00 |
September | 37.13 | 0.03 | 37.10 | 34.93 | 35.41 | 0.00 | 0.00 | 0.00 |
October | 27.06 | 0.00 | 27.06 | 17.71 | 46.52 | 0.00 | 0.00 | 0.00 |
November | 18.39 | 0.00 | 18.39 | 5.46 | 68.82 | 0.00 | 0.00 | 0.00 |
December | 14.19 | 0.00 | 14.19 | 0.83 | 102.85 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 38.26 | 1.59 | 36.67 | 31.80 | 56.31 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 14.19 | 0.00 | 14.19 | 0.83 | 23.98 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 67.58 | 7.72 | 59.86 | 74.87 | 123.66 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 16.92 | 0.00 | 16.92 | 1.22 | 123.66 | 0.00 | 0.00 | 0.00 |
February | 23.89 | 0.00 | 23.89 | 7.11 | 86.25 | 0.00 | 0.00 | 0.00 |
March | 38.81 | 0.00 | 38.81 | 19.85 | 65.34 | 0.00 | 0.00 | 0.00 |
April | 44.38 | 0.34 | 44.04 | 33.07 | 40.92 | 0.00 | 0.00 | 0.00 |
May | 58.06 | 3.40 | 54.66 | 54.76 | 31.31 | 0.00 | 0.00 | 0.00 |
June | 67.58 | 7.72 | 59.86 | 74.86 | 23.98 | 0.00 | 0.00 | 0.00 |
July | 61.73 | 5.71 | 56.02 | 74.45 | 24.81 | 0.00 | 0.00 | 0.00 |
August | 50.05 | 1.81 | 48.24 | 55.58 | 27.00 | 0.00 | 0.00 | 0.00 |
September | 37.13 | 0.03 | 37.10 | 34.93 | 35.41 | 0.00 | 0.00 | 0.00 |
October | 27.06 | 0.00 | 27.06 | 17.70 | 46.52 | 0.00 | 0.00 | 0.00 |
November | 18.39 | 0.00 | 18.39 | 5.46 | 68.82 | 0.00 | 0.00 | 0.00 |
December | 14.19 | 0.00 | 14.19 | 0.83 | 102.85 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 38.26 | 1.59 | 36.67 | 31.79 | 56.31 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 14.19 | 0.00 | 14.19 | 0.83 | 23.98 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 67.58 | 7.72 | 59.86 | 74.86 | 123.66 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 33.62 | 13.79 | 19.83 | 22.59 | 80.89 | 0.00 | 0.00 | 0.00 |
February | 55.70 | 30.49 | 25.21 | 55.35 | 55.68 | 0.00 | 0.00 | 0.00 |
March | 91.69 | 43.70 | 47.99 | 102.50 | 43.98 | 0.00 | 0.00 | 0.00 |
April | 113.83 | 63.71 | 50.11 | 137.09 | 28.49 | 0.00 | 0.00 | 0.00 |
May | 146.15 | 83.47 | 62.68 | 182.77 | 22.53 | 0.00 | 0.00 | 0.00 |
June | 176.04 | 113.13 | 62.91 | 220.86 | 22.67 | 0.00 | 0.00 | 0.00 |
July | 182.29 | 127.67 | 54.62 | 227.19 | 29.24 | 0.00 | 0.00 | 0.00 |
August | 151.80 | 103.60 | 48.20 | 184.75 | 32.46 | 0.00 | 0.00 | 0.00 |
September | 105.26 | 66.79 | 38.47 | 127.65 | 31.93 | 0.00 | 0.00 | 0.00 |
October | 65.26 | 36.19 | 29.07 | 75.33 | 36.38 | 0.00 | 0.00 | 0.00 |
November | 39.29 | 19.15 | 20.14 | 38.76 | 45.76 | 0.00 | 0.00 | 0.00 |
December | 26.30 | 10.10 | 16.20 | 17.91 | 66.47 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 99.18 | 59.48 | 39.70 | 116.40 | 41.36 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 26.30 | 10.10 | 16.20 | 17.91 | 22.53 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 182.29 | 127.67 | 62.91 | 227.19 | 80.89 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 33.62 | 13.79 | 19.83 | 22.59 | 80.89 | 0.00 | 0.00 | 0.00 |
February | 55.70 | 30.49 | 25.21 | 55.35 | 55.68 | 0.00 | 0.00 | 0.00 |
March | 91.69 | 43.70 | 47.99 | 102.50 | 43.98 | 0.00 | 0.00 | 0.00 |
April | 113.83 | 63.71 | 50.11 | 137.09 | 28.49 | 0.00 | 0.00 | 0.00 |
May | 146.15 | 83.47 | 62.68 | 182.77 | 22.53 | 0.00 | 0.00 | 0.00 |
June | 176.04 | 113.13 | 62.91 | 220.86 | 22.67 | 0.00 | 0.00 | 0.00 |
July | 182.29 | 127.67 | 54.62 | 227.19 | 29.24 | 0.00 | 0.00 | 0.00 |
August | 151.80 | 103.60 | 48.20 | 184.75 | 32.46 | 0.00 | 0.00 | 0.00 |
September | 105.26 | 66.79 | 38.47 | 127.65 | 31.93 | 0.00 | 0.00 | 0.00 |
October | 65.26 | 36.19 | 29.07 | 75.33 | 36.38 | 0.00 | 0.00 | 0.00 |
November | 39.29 | 19.15 | 20.14 | 38.76 | 45.76 | 0.00 | 0.00 | 0.00 |
December | 26.30 | 10.10 | 16.20 | 17.91 | 66.47 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 99.18 | 59.48 | 39.70 | 116.40 | 41.36 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 26.30 | 10.10 | 16.20 | 17.91 | 22.53 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 182.29 | 127.67 | 62.91 | 227.19 | 80.89 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 33.62 | 13.79 | 19.83 | 22.59 | 80.89 | 0.00 | 0.00 | 0.00 |
February | 55.70 | 30.49 | 25.21 | 55.35 | 55.68 | 0.00 | 0.00 | 0.00 |
March | 91.69 | 43.70 | 47.99 | 102.50 | 43.98 | 0.00 | 0.00 | 0.00 |
April | 113.83 | 63.71 | 50.11 | 137.09 | 28.49 | 0.00 | 0.00 | 0.00 |
May | 146.15 | 83.47 | 62.68 | 182.77 | 22.53 | 0.00 | 0.00 | 0.00 |
June | 176.04 | 113.13 | 62.91 | 220.86 | 22.67 | 0.00 | 0.00 | 0.00 |
July | 182.29 | 127.67 | 54.62 | 227.19 | 29.24 | 0.00 | 0.00 | 0.00 |
August | 151.80 | 103.60 | 48.20 | 184.75 | 32.46 | 0.00 | 0.00 | 0.00 |
September | 105.26 | 66.79 | 38.47 | 127.65 | 31.93 | 0.00 | 0.00 | 0.00 |
October | 65.26 | 36.19 | 29.07 | 75.33 | 36.38 | 0.00 | 0.00 | 0.00 |
November | 39.29 | 19.15 | 20.14 | 38.76 | 45.76 | 0.00 | 0.00 | 0.00 |
December | 26.30 | 10.10 | 16.20 | 17.91 | 66.47 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 99.18 | 59.48 | 39.70 | 116.40 | 41.36 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 26.30 | 10.10 | 16.20 | 17.91 | 22.53 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 182.29 | 127.67 | 62.91 | 227.19 | 80.89 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 33.62 | 13.79 | 19.83 | 22.59 | 80.89 | 0.00 | 0.00 | 0.00 |
February | 55.70 | 30.49 | 25.21 | 55.35 | 55.68 | 0.00 | 0.00 | 0.00 |
March | 91.69 | 43.70 | 47.99 | 102.50 | 43.98 | 0.00 | 0.00 | 0.00 |
April | 113.83 | 63.71 | 50.11 | 137.09 | 28.49 | 0.00 | 0.00 | 0.00 |
May | 146.15 | 83.47 | 62.68 | 182.77 | 22.53 | 0.00 | 0.00 | 0.00 |
June | 176.04 | 113.13 | 62.91 | 220.86 | 22.67 | 0.00 | 0.00 | 0.00 |
July | 182.29 | 127.67 | 54.62 | 227.19 | 29.24 | 0.00 | 0.00 | 0.00 |
August | 151.80 | 103.60 | 48.20 | 184.75 | 32.46 | 0.00 | 0.00 | 0.00 |
September | 105.26 | 66.79 | 38.47 | 127.65 | 31.93 | 0.00 | 0.00 | 0.00 |
October | 65.26 | 36.19 | 29.07 | 75.33 | 36.38 | 0.00 | 0.00 | 0.00 |
November | 39.29 | 19.15 | 20.14 | 38.76 | 45.76 | 0.00 | 0.00 | 0.00 |
December | 26.30 | 10.10 | 16.20 | 17.91 | 66.47 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 99.18 | 59.48 | 39.70 | 116.40 | 41.36 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 26.30 | 10.10 | 16.20 | 17.91 | 22.53 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 182.29 | 127.67 | 62.91 | 227.19 | 80.89 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C5
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 33.62 | 13.79 | 19.83 | 22.59 | 80.89 | 0.00 | 0.00 | 0.00 |
February | 55.70 | 30.49 | 25.21 | 55.35 | 55.68 | 0.00 | 0.00 | 0.00 |
March | 91.69 | 43.70 | 47.99 | 102.50 | 43.98 | 0.00 | 0.00 | 0.00 |
April | 113.83 | 63.71 | 50.11 | 137.09 | 28.49 | 0.00 | 0.00 | 0.00 |
May | 146.15 | 83.47 | 62.68 | 182.77 | 22.53 | 0.00 | 0.00 | 0.00 |
June | 176.04 | 113.13 | 62.91 | 220.86 | 22.67 | 0.00 | 0.00 | 0.00 |
July | 182.29 | 127.67 | 54.62 | 227.19 | 29.24 | 0.00 | 0.00 | 0.00 |
August | 151.80 | 103.60 | 48.20 | 184.75 | 32.46 | 0.00 | 0.00 | 0.00 |
September | 105.26 | 66.79 | 38.47 | 127.65 | 31.93 | 0.00 | 0.00 | 0.00 |
October | 65.26 | 36.19 | 29.07 | 75.33 | 36.38 | 0.00 | 0.00 | 0.00 |
November | 39.29 | 19.15 | 20.14 | 38.76 | 45.76 | 0.00 | 0.00 | 0.00 |
December | 26.30 | 10.10 | 16.20 | 17.91 | 66.47 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 99.18 | 59.48 | 39.70 | 116.40 | 41.36 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 26.30 | 10.10 | 16.20 | 17.91 | 22.53 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 182.29 | 127.67 | 62.91 | 227.19 | 80.89 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 33.62 | 13.79 | 19.83 | 22.59 | 80.89 | 0.00 | 0.00 | 0.00 |
February | 55.70 | 30.49 | 25.21 | 55.35 | 55.68 | 0.00 | 0.00 | 0.00 |
March | 91.69 | 43.70 | 47.99 | 102.50 | 43.98 | 0.00 | 0.00 | 0.00 |
April | 113.83 | 63.71 | 50.11 | 137.09 | 28.49 | 0.00 | 0.00 | 0.00 |
May | 146.15 | 83.47 | 62.68 | 182.77 | 22.53 | 0.00 | 0.00 | 0.00 |
June | 176.04 | 113.13 | 62.91 | 220.86 | 22.67 | 0.00 | 0.00 | 0.00 |
July | 182.29 | 127.67 | 54.62 | 227.19 | 29.24 | 0.00 | 0.00 | 0.00 |
August | 151.80 | 103.60 | 48.20 | 184.75 | 32.46 | 0.00 | 0.00 | 0.00 |
September | 105.26 | 66.79 | 38.47 | 127.65 | 31.93 | 0.00 | 0.00 | 0.00 |
October | 65.26 | 36.19 | 29.07 | 75.33 | 36.38 | 0.00 | 0.00 | 0.00 |
November | 39.29 | 19.15 | 20.14 | 38.76 | 45.76 | 0.00 | 0.00 | 0.00 |
December | 26.30 | 10.10 | 16.20 | 17.91 | 66.47 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 99.18 | 59.48 | 39.70 | 116.40 | 41.36 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 26.30 | 10.10 | 16.20 | 17.91 | 22.53 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 182.29 | 127.67 | 62.91 | 227.19 | 80.89 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 33.62 | 13.79 | 19.83 | 22.59 | 80.89 | 0.00 | 0.00 | 0.00 |
February | 55.70 | 30.49 | 25.21 | 55.35 | 55.68 | 0.00 | 0.00 | 0.00 |
March | 91.69 | 43.70 | 47.99 | 102.50 | 43.98 | 0.00 | 0.00 | 0.00 |
April | 113.83 | 63.71 | 50.11 | 137.09 | 28.49 | 0.00 | 0.00 | 0.00 |
May | 146.15 | 83.47 | 62.68 | 182.77 | 22.53 | 0.00 | 0.00 | 0.00 |
June | 176.04 | 113.13 | 62.91 | 220.86 | 22.67 | 0.00 | 0.00 | 0.00 |
July | 182.29 | 127.67 | 54.62 | 227.19 | 29.24 | 0.00 | 0.00 | 0.00 |
August | 151.80 | 103.60 | 48.20 | 184.75 | 32.46 | 0.00 | 0.00 | 0.00 |
September | 105.26 | 66.79 | 38.47 | 127.65 | 31.93 | 0.00 | 0.00 | 0.00 |
October | 65.26 | 36.19 | 29.07 | 75.33 | 36.38 | 0.00 | 0.00 | 0.00 |
November | 39.29 | 19.15 | 20.14 | 38.76 | 45.76 | 0.00 | 0.00 | 0.00 |
December | 26.30 | 10.10 | 16.20 | 17.91 | 66.47 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 99.18 | 59.48 | 39.70 | 116.40 | 41.36 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 26.30 | 10.10 | 16.20 | 17.91 | 22.53 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 182.29 | 127.67 | 62.91 | 227.19 | 80.89 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 33.62 | 13.79 | 19.83 | 22.59 | 80.89 | 0.00 | 0.00 | 0.00 |
February | 55.70 | 30.49 | 25.21 | 55.35 | 55.68 | 0.00 | 0.00 | 0.00 |
March | 91.69 | 43.70 | 47.99 | 102.50 | 43.98 | 0.00 | 0.00 | 0.00 |
April | 113.83 | 63.71 | 50.11 | 137.09 | 28.49 | 0.00 | 0.00 | 0.00 |
May | 146.15 | 83.47 | 62.68 | 182.77 | 22.53 | 0.00 | 0.00 | 0.00 |
June | 176.04 | 113.13 | 62.91 | 220.86 | 22.67 | 0.00 | 0.00 | 0.00 |
July | 182.29 | 127.67 | 54.62 | 227.19 | 29.24 | 0.00 | 0.00 | 0.00 |
August | 151.80 | 103.60 | 48.20 | 184.75 | 32.46 | 0.00 | 0.00 | 0.00 |
September | 105.26 | 66.79 | 38.47 | 127.65 | 31.93 | 0.00 | 0.00 | 0.00 |
October | 65.26 | 36.19 | 29.07 | 75.33 | 36.38 | 0.00 | 0.00 | 0.00 |
November | 39.29 | 19.15 | 20.14 | 38.76 | 45.76 | 0.00 | 0.00 | 0.00 |
December | 26.30 | 10.10 | 16.20 | 17.91 | 66.47 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 99.18 | 59.48 | 39.70 | 116.40 | 41.36 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 26.30 | 10.10 | 16.20 | 17.91 | 22.53 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 182.29 | 127.67 | 62.91 | 227.19 | 80.89 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 33.62 | 13.79 | 19.83 | 22.59 | 80.89 | 0.00 | 0.00 | 0.00 |
February | 55.70 | 30.49 | 25.21 | 55.35 | 55.68 | 0.00 | 0.00 | 0.00 |
March | 91.69 | 43.70 | 47.99 | 102.50 | 43.98 | 0.00 | 0.00 | 0.00 |
April | 113.83 | 63.71 | 50.11 | 137.09 | 28.49 | 0.00 | 0.00 | 0.00 |
May | 146.15 | 83.47 | 62.68 | 182.77 | 22.53 | 0.00 | 0.00 | 0.00 |
June | 176.04 | 113.13 | 62.91 | 220.86 | 22.67 | 0.00 | 0.00 | 0.00 |
July | 182.29 | 127.67 | 54.62 | 227.19 | 29.24 | 0.00 | 0.00 | 0.00 |
August | 151.80 | 103.60 | 48.20 | 184.75 | 32.46 | 0.00 | 0.00 | 0.00 |
September | 105.26 | 66.79 | 38.47 | 127.65 | 31.93 | 0.00 | 0.00 | 0.00 |
October | 65.26 | 36.19 | 29.07 | 75.33 | 36.38 | 0.00 | 0.00 | 0.00 |
November | 39.29 | 19.15 | 20.14 | 38.76 | 45.76 | 0.00 | 0.00 | 0.00 |
December | 26.30 | 10.10 | 16.20 | 17.91 | 66.47 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 99.18 | 59.48 | 39.70 | 116.40 | 41.36 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 26.30 | 10.10 | 16.20 | 17.91 | 22.53 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 182.29 | 127.67 | 62.91 | 227.19 | 80.89 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C5
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 33.62 | 13.79 | 19.83 | 22.59 | 80.89 | 0.00 | 0.00 | 0.00 |
February | 55.70 | 30.49 | 25.21 | 55.35 | 55.68 | 0.00 | 0.00 | 0.00 |
March | 91.69 | 43.70 | 47.99 | 102.50 | 43.98 | 0.00 | 0.00 | 0.00 |
April | 113.83 | 63.71 | 50.11 | 137.09 | 28.49 | 0.00 | 0.00 | 0.00 |
May | 146.15 | 83.47 | 62.68 | 182.77 | 22.53 | 0.00 | 0.00 | 0.00 |
June | 176.04 | 113.13 | 62.91 | 220.86 | 22.67 | 0.00 | 0.00 | 0.00 |
July | 182.29 | 127.67 | 54.62 | 227.19 | 29.24 | 0.00 | 0.00 | 0.00 |
August | 151.80 | 103.60 | 48.20 | 184.75 | 32.46 | 0.00 | 0.00 | 0.00 |
September | 105.26 | 66.79 | 38.47 | 127.65 | 31.93 | 0.00 | 0.00 | 0.00 |
October | 65.26 | 36.19 | 29.07 | 75.33 | 36.38 | 0.00 | 0.00 | 0.00 |
November | 39.29 | 19.15 | 20.14 | 38.76 | 45.76 | 0.00 | 0.00 | 0.00 |
December | 26.30 | 10.10 | 16.20 | 17.91 | 66.47 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 99.18 | 59.48 | 39.70 | 116.40 | 41.36 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 26.30 | 10.10 | 16.20 | 17.91 | 22.53 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 182.29 | 127.67 | 62.91 | 227.19 | 80.89 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.162577E+09 | 66037905.05 | 96539375.11 | 94345446.01 | 0.538232E+09 |
February | 0.248787E+09 | 0.122439E+09 | 0.126349E+09 | 0.217097E+09 | 0.333849E+09 |
March | 0.353601E+09 | 0.129872E+09 | 0.223729E+09 | 0.324589E+09 | 0.292300E+09 |
April | 0.445933E+09 | 0.196986E+09 | 0.248947E+09 | 0.489439E+09 | 0.183235E+09 |
May | 0.570079E+09 | 0.260071E+09 | 0.310008E+09 | 0.667899E+09 | 0.149892E+09 |
June | 0.599755E+09 | 0.275395E+09 | 0.324360E+09 | 0.746682E+09 | 0.117707E+09 |
July | 0.635532E+09 | 0.321287E+09 | 0.314245E+09 | 0.830064E+09 | 0.123454E+09 |
August | 0.538498E+09 | 0.263569E+09 | 0.274928E+09 | 0.687842E+09 | 0.130438E+09 |
September | 0.419581E+09 | 0.212003E+09 | 0.207578E+09 | 0.507053E+09 | 0.156465E+09 |
October | 0.310496E+09 | 0.154341E+09 | 0.156155E+09 | 0.336359E+09 | 0.208810E+09 |
November | 0.212327E+09 | 0.105344E+09 | 0.106983E+09 | 0.191112E+09 | 0.288930E+09 |
December | 0.147186E+09 | 62016452.46 | 85169427.26 | 92609347.87 | 0.445879E+09 |
Annual Sum or Average | 0.464435E+10 | 0.216936E+10 | 0.247499E+10 | 0.518509E+10 | 0.296919E+10 |
Minimum of Months | 0.147186E+09 | 62016452.46 | 85169427.26 | 92609347.87 | 0.117707E+09 |
Maximum of Months | 0.635532E+09 | 0.321287E+09 | 0.324360E+09 | 0.830064E+09 | 0.538232E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.162577E+09 | 66037905.05 | 96539375.11 | 94345446.01 | 0.538232E+09 |
February | 0.248787E+09 | 0.122439E+09 | 0.126349E+09 | 0.217097E+09 | 0.333849E+09 |
March | 0.353601E+09 | 0.129872E+09 | 0.223729E+09 | 0.324589E+09 | 0.292300E+09 |
April | 0.445933E+09 | 0.196986E+09 | 0.248947E+09 | 0.489439E+09 | 0.183235E+09 |
May | 0.570079E+09 | 0.260071E+09 | 0.310008E+09 | 0.667899E+09 | 0.149892E+09 |
June | 0.599755E+09 | 0.275395E+09 | 0.324360E+09 | 0.746682E+09 | 0.117707E+09 |
July | 0.635532E+09 | 0.321287E+09 | 0.314245E+09 | 0.830064E+09 | 0.123454E+09 |
August | 0.538498E+09 | 0.263569E+09 | 0.274928E+09 | 0.687842E+09 | 0.130438E+09 |
September | 0.419581E+09 | 0.212003E+09 | 0.207578E+09 | 0.507053E+09 | 0.156465E+09 |
October | 0.310496E+09 | 0.154341E+09 | 0.156155E+09 | 0.336359E+09 | 0.208810E+09 |
November | 0.212327E+09 | 0.105344E+09 | 0.106983E+09 | 0.191112E+09 | 0.288930E+09 |
December | 0.147186E+09 | 62016452.46 | 85169427.26 | 92609347.87 | 0.445879E+09 |
Annual Sum or Average | 0.464435E+10 | 0.216936E+10 | 0.247499E+10 | 0.518509E+10 | 0.296919E+10 |
Minimum of Months | 0.147186E+09 | 62016452.46 | 85169427.26 | 92609347.87 | 0.117707E+09 |
Maximum of Months | 0.635532E+09 | 0.321287E+09 | 0.324360E+09 | 0.830064E+09 | 0.538232E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 45315351.18 | 0.00 | 45315351.18 | 3276884.05 | 0.331201E+09 |
February | 57790609.70 | 0.00 | 57790609.70 | 17190197.16 | 0.208649E+09 |
March | 0.103949E+09 | 5392.55 | 0.103944E+09 | 53170987.72 | 0.174997E+09 |
April | 0.115036E+09 | 869215.31 | 0.114167E+09 | 85708138.99 | 0.106059E+09 |
May | 0.155521E+09 | 9102545.10 | 0.146419E+09 | 0.146668E+09 | 83871522.54 |
June | 0.175168E+09 | 20008153.08 | 0.155160E+09 | 0.194052E+09 | 62161385.14 |
July | 0.165333E+09 | 15282220.08 | 0.150051E+09 | 0.199425E+09 | 66442472.31 |
August | 0.134048E+09 | 4836218.95 | 0.129212E+09 | 0.148859E+09 | 72315197.17 |
September | 96248574.06 | 84013.27 | 96164560.79 | 90536411.24 | 91778766.16 |
October | 72473966.78 | 0.00 | 72473966.78 | 47422035.84 | 0.124591E+09 |
November | 47679171.03 | 0.00 | 47679171.03 | 14162394.62 | 0.178394E+09 |
December | 37999475.76 | 0.00 | 37999475.76 | 2227870.30 | 0.275463E+09 |
Annual Sum or Average | 0.120656E+10 | 50187758.32 | 0.115637E+10 | 0.100270E+10 | 0.177592E+10 |
Minimum of Months | 37999475.76 | 0.00 | 37999475.76 | 2227870.30 | 62161385.14 |
Maximum of Months | 0.175168E+09 | 20008153.08 | 0.155160E+09 | 0.199425E+09 | 0.331201E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 45313889.90 | 0.00 | 45313889.90 | 3276523.60 | 0.331202E+09 |
February | 57788869.36 | 0.00 | 57788869.36 | 17189173.63 | 0.208649E+09 |
March | 0.103946E+09 | 5392.29 | 0.103940E+09 | 53167756.35 | 0.174997E+09 |
April | 0.115033E+09 | 869174.57 | 0.114164E+09 | 85704529.20 | 0.106059E+09 |
May | 0.155516E+09 | 9102118.45 | 0.146414E+09 | 0.146662E+09 | 83871236.07 |
June | 0.175163E+09 | 20007215.27 | 0.155156E+09 | 0.194045E+09 | 62161049.40 |
July | 0.165328E+09 | 15281503.78 | 0.150047E+09 | 0.199419E+09 | 66441892.53 |
August | 0.134044E+09 | 4835992.27 | 0.129208E+09 | 0.148854E+09 | 72314675.30 |
September | 96245820.49 | 84009.33 | 96161811.16 | 90533498.43 | 91778306.12 |
October | 72471771.98 | 0.00 | 72471771.98 | 47419907.37 | 0.124590E+09 |
November | 47677675.86 | 0.00 | 47677675.86 | 14161553.00 | 0.178394E+09 |
December | 37998233.75 | 0.00 | 37998233.75 | 2227607.73 | 0.275463E+09 |
Annual Sum or Average | 0.120653E+10 | 50185405.95 | 0.115634E+10 | 0.100266E+10 | 0.177592E+10 |
Minimum of Months | 37998233.75 | 0.00 | 37998233.75 | 2227607.73 | 62161049.40 |
Maximum of Months | 0.175163E+09 | 20007215.27 | 0.155156E+09 | 0.199419E+09 | 0.331202E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 90039538.14 | 36935220.71 | 53104317.43 | 60507934.02 | 0.216667E+09 |
February | 0.134738E+09 | 73754214.89 | 60983837.93 | 0.133914E+09 | 0.134711E+09 |
March | 0.245593E+09 | 0.117044E+09 | 0.128548E+09 | 0.274534E+09 | 0.117796E+09 |
April | 0.295043E+09 | 0.165146E+09 | 0.129898E+09 | 0.355339E+09 | 73844499.74 |
May | 0.391441E+09 | 0.223565E+09 | 0.167876E+09 | 0.489525E+09 | 60345350.50 |
June | 0.456284E+09 | 0.293227E+09 | 0.163057E+09 | 0.572474E+09 | 58753725.39 |
July | 0.488238E+09 | 0.341938E+09 | 0.146300E+09 | 0.608497E+09 | 78319906.80 |
August | 0.406570E+09 | 0.277477E+09 | 0.129093E+09 | 0.494830E+09 | 86928848.88 |
September | 0.272841E+09 | 0.173124E+09 | 99716486.23 | 0.330878E+09 | 82763351.79 |
October | 0.174803E+09 | 96936501.88 | 77866995.65 | 0.201762E+09 | 97442319.65 |
November | 0.101846E+09 | 49645221.90 | 52200518.88 | 0.100471E+09 | 0.118601E+09 |
December | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 0.178033E+09 |
Annual Sum or Average | 0.312787E+10 | 0.187584E+10 | 0.125203E+10 | 0.367070E+10 | 0.130421E+10 |
Minimum of Months | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 58753725.39 |
Maximum of Months | 0.488238E+09 | 0.341938E+09 | 0.167876E+09 | 0.608497E+09 | 0.216667E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 90039538.14 | 36935220.71 | 53104317.43 | 60507934.02 | 0.216667E+09 |
February | 0.134738E+09 | 73754214.89 | 60983837.93 | 0.133914E+09 | 0.134711E+09 |
March | 0.245593E+09 | 0.117044E+09 | 0.128548E+09 | 0.274534E+09 | 0.117796E+09 |
April | 0.295043E+09 | 0.165146E+09 | 0.129898E+09 | 0.355339E+09 | 73844499.74 |
May | 0.391441E+09 | 0.223565E+09 | 0.167876E+09 | 0.489525E+09 | 60345350.50 |
June | 0.456284E+09 | 0.293227E+09 | 0.163057E+09 | 0.572474E+09 | 58753725.39 |
July | 0.488238E+09 | 0.341938E+09 | 0.146300E+09 | 0.608497E+09 | 78319906.80 |
August | 0.406570E+09 | 0.277477E+09 | 0.129093E+09 | 0.494830E+09 | 86928848.88 |
September | 0.272841E+09 | 0.173124E+09 | 99716486.23 | 0.330878E+09 | 82763351.79 |
October | 0.174803E+09 | 96936501.88 | 77866995.65 | 0.201762E+09 | 97442319.65 |
November | 0.101846E+09 | 49645221.90 | 52200518.88 | 0.100471E+09 | 0.118601E+09 |
December | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 0.178033E+09 |
Annual Sum or Average | 0.312787E+10 | 0.187584E+10 | 0.125203E+10 | 0.367070E+10 | 0.130421E+10 |
Minimum of Months | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 58753725.39 |
Maximum of Months | 0.488238E+09 | 0.341938E+09 | 0.167876E+09 | 0.608497E+09 | 0.216667E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 90039538.14 | 36935220.71 | 53104317.43 | 60507934.02 | 0.216667E+09 |
February | 0.134738E+09 | 73754214.89 | 60983837.93 | 0.133914E+09 | 0.134711E+09 |
March | 0.245593E+09 | 0.117044E+09 | 0.128548E+09 | 0.274534E+09 | 0.117796E+09 |
April | 0.295043E+09 | 0.165146E+09 | 0.129898E+09 | 0.355339E+09 | 73844499.74 |
May | 0.391441E+09 | 0.223565E+09 | 0.167876E+09 | 0.489525E+09 | 60345350.50 |
June | 0.456284E+09 | 0.293227E+09 | 0.163057E+09 | 0.572474E+09 | 58753725.39 |
July | 0.488238E+09 | 0.341938E+09 | 0.146300E+09 | 0.608497E+09 | 78319906.80 |
August | 0.406570E+09 | 0.277477E+09 | 0.129093E+09 | 0.494830E+09 | 86928848.88 |
September | 0.272841E+09 | 0.173124E+09 | 99716486.23 | 0.330878E+09 | 82763351.79 |
October | 0.174803E+09 | 96936501.88 | 77866995.65 | 0.201762E+09 | 97442319.65 |
November | 0.101846E+09 | 49645221.90 | 52200518.88 | 0.100471E+09 | 0.118601E+09 |
December | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 0.178033E+09 |
Annual Sum or Average | 0.312787E+10 | 0.187584E+10 | 0.125203E+10 | 0.367070E+10 | 0.130421E+10 |
Minimum of Months | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 58753725.39 |
Maximum of Months | 0.488238E+09 | 0.341938E+09 | 0.167876E+09 | 0.608497E+09 | 0.216667E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 90039538.14 | 36935220.71 | 53104317.43 | 60507934.02 | 0.216667E+09 |
February | 0.134738E+09 | 73754214.89 | 60983837.93 | 0.133914E+09 | 0.134711E+09 |
March | 0.245593E+09 | 0.117044E+09 | 0.128548E+09 | 0.274534E+09 | 0.117796E+09 |
April | 0.295043E+09 | 0.165146E+09 | 0.129898E+09 | 0.355339E+09 | 73844499.74 |
May | 0.391441E+09 | 0.223565E+09 | 0.167876E+09 | 0.489525E+09 | 60345350.50 |
June | 0.456284E+09 | 0.293227E+09 | 0.163057E+09 | 0.572474E+09 | 58753725.39 |
July | 0.488238E+09 | 0.341938E+09 | 0.146300E+09 | 0.608497E+09 | 78319906.80 |
August | 0.406570E+09 | 0.277477E+09 | 0.129093E+09 | 0.494830E+09 | 86928848.88 |
September | 0.272841E+09 | 0.173124E+09 | 99716486.23 | 0.330878E+09 | 82763351.79 |
October | 0.174803E+09 | 96936501.88 | 77866995.65 | 0.201762E+09 | 97442319.65 |
November | 0.101846E+09 | 49645221.90 | 52200518.88 | 0.100471E+09 | 0.118601E+09 |
December | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 0.178033E+09 |
Annual Sum or Average | 0.312787E+10 | 0.187584E+10 | 0.125203E+10 | 0.367070E+10 | 0.130421E+10 |
Minimum of Months | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 58753725.39 |
Maximum of Months | 0.488238E+09 | 0.341938E+09 | 0.167876E+09 | 0.608497E+09 | 0.216667E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C5
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 90039538.14 | 36935220.71 | 53104317.43 | 60507934.02 | 0.216667E+09 |
February | 0.134738E+09 | 73754214.89 | 60983837.93 | 0.133914E+09 | 0.134711E+09 |
March | 0.245593E+09 | 0.117044E+09 | 0.128548E+09 | 0.274534E+09 | 0.117796E+09 |
April | 0.295043E+09 | 0.165146E+09 | 0.129898E+09 | 0.355339E+09 | 73844499.74 |
May | 0.391441E+09 | 0.223565E+09 | 0.167876E+09 | 0.489525E+09 | 60345350.50 |
June | 0.456284E+09 | 0.293227E+09 | 0.163057E+09 | 0.572474E+09 | 58753725.39 |
July | 0.488238E+09 | 0.341938E+09 | 0.146300E+09 | 0.608497E+09 | 78319906.80 |
August | 0.406570E+09 | 0.277477E+09 | 0.129093E+09 | 0.494830E+09 | 86928848.88 |
September | 0.272841E+09 | 0.173124E+09 | 99716486.23 | 0.330878E+09 | 82763351.79 |
October | 0.174803E+09 | 96936501.88 | 77866995.65 | 0.201762E+09 | 97442319.65 |
November | 0.101846E+09 | 49645221.90 | 52200518.88 | 0.100471E+09 | 0.118601E+09 |
December | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 0.178033E+09 |
Annual Sum or Average | 0.312787E+10 | 0.187584E+10 | 0.125203E+10 | 0.367070E+10 | 0.130421E+10 |
Minimum of Months | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 58753725.39 |
Maximum of Months | 0.488238E+09 | 0.341938E+09 | 0.167876E+09 | 0.608497E+09 | 0.216667E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 90039538.14 | 36935220.71 | 53104317.43 | 60507934.02 | 0.216667E+09 |
February | 0.134738E+09 | 73754214.89 | 60983837.93 | 0.133914E+09 | 0.134711E+09 |
March | 0.245593E+09 | 0.117044E+09 | 0.128548E+09 | 0.274534E+09 | 0.117796E+09 |
April | 0.295043E+09 | 0.165146E+09 | 0.129898E+09 | 0.355339E+09 | 73844499.74 |
May | 0.391441E+09 | 0.223565E+09 | 0.167876E+09 | 0.489525E+09 | 60345350.50 |
June | 0.456284E+09 | 0.293227E+09 | 0.163057E+09 | 0.572474E+09 | 58753725.39 |
July | 0.488238E+09 | 0.341938E+09 | 0.146300E+09 | 0.608497E+09 | 78319906.80 |
August | 0.406570E+09 | 0.277477E+09 | 0.129093E+09 | 0.494830E+09 | 86928848.88 |
September | 0.272841E+09 | 0.173124E+09 | 99716486.23 | 0.330878E+09 | 82763351.79 |
October | 0.174803E+09 | 96936501.88 | 77866995.65 | 0.201762E+09 | 97442319.65 |
November | 0.101846E+09 | 49645221.90 | 52200518.88 | 0.100471E+09 | 0.118601E+09 |
December | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 0.178033E+09 |
Annual Sum or Average | 0.312787E+10 | 0.187584E+10 | 0.125203E+10 | 0.367070E+10 | 0.130421E+10 |
Minimum of Months | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 58753725.39 |
Maximum of Months | 0.488238E+09 | 0.341938E+09 | 0.167876E+09 | 0.608497E+09 | 0.216667E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 90039538.14 | 36935220.71 | 53104317.43 | 60507934.02 | 0.216667E+09 |
February | 0.134738E+09 | 73754214.89 | 60983837.93 | 0.133914E+09 | 0.134711E+09 |
March | 0.245593E+09 | 0.117044E+09 | 0.128548E+09 | 0.274534E+09 | 0.117796E+09 |
April | 0.295043E+09 | 0.165146E+09 | 0.129898E+09 | 0.355339E+09 | 73844499.74 |
May | 0.391441E+09 | 0.223565E+09 | 0.167876E+09 | 0.489525E+09 | 60345350.50 |
June | 0.456284E+09 | 0.293227E+09 | 0.163057E+09 | 0.572474E+09 | 58753725.39 |
July | 0.488238E+09 | 0.341938E+09 | 0.146300E+09 | 0.608497E+09 | 78319906.80 |
August | 0.406570E+09 | 0.277477E+09 | 0.129093E+09 | 0.494830E+09 | 86928848.88 |
September | 0.272841E+09 | 0.173124E+09 | 99716486.23 | 0.330878E+09 | 82763351.79 |
October | 0.174803E+09 | 96936501.88 | 77866995.65 | 0.201762E+09 | 97442319.65 |
November | 0.101846E+09 | 49645221.90 | 52200518.88 | 0.100471E+09 | 0.118601E+09 |
December | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 0.178033E+09 |
Annual Sum or Average | 0.312787E+10 | 0.187584E+10 | 0.125203E+10 | 0.367070E+10 | 0.130421E+10 |
Minimum of Months | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 58753725.39 |
Maximum of Months | 0.488238E+09 | 0.341938E+09 | 0.167876E+09 | 0.608497E+09 | 0.216667E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 90039538.14 | 36935220.71 | 53104317.43 | 60507934.02 | 0.216667E+09 |
February | 0.134738E+09 | 73754214.89 | 60983837.93 | 0.133914E+09 | 0.134711E+09 |
March | 0.245593E+09 | 0.117044E+09 | 0.128548E+09 | 0.274534E+09 | 0.117796E+09 |
April | 0.295043E+09 | 0.165146E+09 | 0.129898E+09 | 0.355339E+09 | 73844499.74 |
May | 0.391441E+09 | 0.223565E+09 | 0.167876E+09 | 0.489525E+09 | 60345350.50 |
June | 0.456284E+09 | 0.293227E+09 | 0.163057E+09 | 0.572474E+09 | 58753725.39 |
July | 0.488238E+09 | 0.341938E+09 | 0.146300E+09 | 0.608497E+09 | 78319906.80 |
August | 0.406570E+09 | 0.277477E+09 | 0.129093E+09 | 0.494830E+09 | 86928848.88 |
September | 0.272841E+09 | 0.173124E+09 | 99716486.23 | 0.330878E+09 | 82763351.79 |
October | 0.174803E+09 | 96936501.88 | 77866995.65 | 0.201762E+09 | 97442319.65 |
November | 0.101846E+09 | 49645221.90 | 52200518.88 | 0.100471E+09 | 0.118601E+09 |
December | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 0.178033E+09 |
Annual Sum or Average | 0.312787E+10 | 0.187584E+10 | 0.125203E+10 | 0.367070E+10 | 0.130421E+10 |
Minimum of Months | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 58753725.39 |
Maximum of Months | 0.488238E+09 | 0.341938E+09 | 0.167876E+09 | 0.608497E+09 | 0.216667E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 90039538.14 | 36935220.71 | 53104317.43 | 60507934.02 | 0.216667E+09 |
February | 0.134738E+09 | 73754214.89 | 60983837.93 | 0.133914E+09 | 0.134711E+09 |
March | 0.245593E+09 | 0.117044E+09 | 0.128548E+09 | 0.274534E+09 | 0.117796E+09 |
April | 0.295043E+09 | 0.165146E+09 | 0.129898E+09 | 0.355339E+09 | 73844499.74 |
May | 0.391441E+09 | 0.223565E+09 | 0.167876E+09 | 0.489525E+09 | 60345350.50 |
June | 0.456284E+09 | 0.293227E+09 | 0.163057E+09 | 0.572474E+09 | 58753725.39 |
July | 0.488238E+09 | 0.341938E+09 | 0.146300E+09 | 0.608497E+09 | 78319906.80 |
August | 0.406570E+09 | 0.277477E+09 | 0.129093E+09 | 0.494830E+09 | 86928848.88 |
September | 0.272841E+09 | 0.173124E+09 | 99716486.23 | 0.330878E+09 | 82763351.79 |
October | 0.174803E+09 | 96936501.88 | 77866995.65 | 0.201762E+09 | 97442319.65 |
November | 0.101846E+09 | 49645221.90 | 52200518.88 | 0.100471E+09 | 0.118601E+09 |
December | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 0.178033E+09 |
Annual Sum or Average | 0.312787E+10 | 0.187584E+10 | 0.125203E+10 | 0.367070E+10 | 0.130421E+10 |
Minimum of Months | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 58753725.39 |
Maximum of Months | 0.488238E+09 | 0.341938E+09 | 0.167876E+09 | 0.608497E+09 | 0.216667E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C5
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 90039538.14 | 36935220.71 | 53104317.43 | 60507934.02 | 0.216667E+09 |
February | 0.134738E+09 | 73754214.89 | 60983837.93 | 0.133914E+09 | 0.134711E+09 |
March | 0.245593E+09 | 0.117044E+09 | 0.128548E+09 | 0.274534E+09 | 0.117796E+09 |
April | 0.295043E+09 | 0.165146E+09 | 0.129898E+09 | 0.355339E+09 | 73844499.74 |
May | 0.391441E+09 | 0.223565E+09 | 0.167876E+09 | 0.489525E+09 | 60345350.50 |
June | 0.456284E+09 | 0.293227E+09 | 0.163057E+09 | 0.572474E+09 | 58753725.39 |
July | 0.488238E+09 | 0.341938E+09 | 0.146300E+09 | 0.608497E+09 | 78319906.80 |
August | 0.406570E+09 | 0.277477E+09 | 0.129093E+09 | 0.494830E+09 | 86928848.88 |
September | 0.272841E+09 | 0.173124E+09 | 99716486.23 | 0.330878E+09 | 82763351.79 |
October | 0.174803E+09 | 96936501.88 | 77866995.65 | 0.201762E+09 | 97442319.65 |
November | 0.101846E+09 | 49645221.90 | 52200518.88 | 0.100471E+09 | 0.118601E+09 |
December | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 0.178033E+09 |
Annual Sum or Average | 0.312787E+10 | 0.187584E+10 | 0.125203E+10 | 0.367070E+10 | 0.130421E+10 |
Minimum of Months | 70432410.14 | 27049437.42 | 43382972.73 | 47965026.46 | 58753725.39 |
Maximum of Months | 0.488238E+09 | 0.341938E+09 | 0.167876E+09 | 0.608497E+09 | 0.216667E+09 |
Report: WindowZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 63.88 | 640.20 | 155.24 | 49.31 | 105.92 | 0.00 | 0.00 |
February | 185.63 | 440.43 | 253.45 | 101.22 | 152.23 | 0.00 | 0.00 |
March | 279.39 | 346.25 | 341.66 | 96.98 | 244.68 | 0.00 | 0.00 |
April | 443.03 | 222.46 | 432.85 | 152.67 | 280.18 | 0.00 | 0.00 |
May | 605.76 | 172.07 | 541.81 | 201.00 | 340.82 | 0.00 | 0.00 |
June | 721.23 | 134.15 | 597.93 | 227.93 | 370.00 | 0.00 | 0.00 |
July | 764.02 | 137.09 | 598.02 | 251.32 | 346.69 | 0.00 | 0.00 |
August | 622.99 | 149.62 | 502.20 | 200.42 | 301.78 | 0.00 | 0.00 |
September | 460.32 | 190.77 | 398.02 | 163.65 | 234.37 | 0.00 | 0.00 |
October | 284.43 | 246.81 | 285.97 | 115.25 | 170.72 | 0.00 | 0.00 |
November | 151.25 | 353.45 | 200.62 | 81.28 | 119.34 | 0.00 | 0.00 |
December | 61.73 | 529.55 | 138.28 | 46.31 | 91.97 | 0.00 | 0.00 |
Annual Sum or Average | 388.00 | 296.51 | 371.06 | 140.76 | 230.30 | 0.00 | 0.00 |
Minimum of Months | 61.73 | 134.15 | 138.28 | 46.31 | 91.97 | 0.00 | 0.00 |
Maximum of Months | 764.02 | 640.20 | 598.02 | 251.32 | 370.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1164.03 | 7495.24 | 336.17 | 137.90 | 198.27 | 0.00 | 0.00 |
February | 2491.35 | 4374.20 | 556.95 | 304.87 | 252.08 | 0.00 | 0.00 |
March | 4626.54 | 3151.20 | 916.94 | 436.99 | 479.94 | 0.00 | 0.00 |
April | 5648.37 | 1478.54 | 1138.28 | 637.14 | 501.15 | 0.00 | 0.00 |
May | 7516.09 | 974.82 | 1461.47 | 834.70 | 626.78 | 0.00 | 0.00 |
June | 9025.66 | 683.20 | 1760.35 | 1131.28 | 629.08 | 0.00 | 0.00 |
July | 8968.93 | 886.53 | 1822.87 | 1276.65 | 546.22 | 0.00 | 0.00 |
August | 7495.24 | 993.68 | 1517.96 | 1035.98 | 481.98 | 0.00 | 0.00 |
September | 5179.81 | 1028.50 | 1052.63 | 667.92 | 384.71 | 0.00 | 0.00 |
October | 3077.71 | 1456.65 | 652.64 | 361.92 | 290.72 | 0.00 | 0.00 |
November | 1684.52 | 2938.47 | 392.92 | 191.53 | 201.39 | 0.00 | 0.00 |
December | 884.85 | 5123.82 | 262.96 | 100.99 | 161.97 | 0.00 | 0.00 |
Annual Sum or Average | 4826.42 | 2544.87 | 991.84 | 594.83 | 397.02 | 0.00 | 0.00 |
Minimum of Months | 884.85 | 683.20 | 262.96 | 100.99 | 161.97 | 0.00 | 0.00 |
Maximum of Months | 9025.66 | 7495.24 | 1822.87 | 1276.65 | 629.08 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.171095E+09 | 0.171472E+10 | 0.415784E+09 | 0.132076E+09 | 0.283708E+09 | 0.00 | 0.00 |
February | 0.449066E+09 | 0.106549E+10 | 0.613154E+09 | 0.244877E+09 | 0.368277E+09 | 0.00 | 0.00 |
March | 0.748316E+09 | 0.927392E+09 | 0.915097E+09 | 0.259755E+09 | 0.655341E+09 | 0.00 | 0.00 |
April | 0.114833E+10 | 0.576622E+09 | 0.112193E+10 | 0.395710E+09 | 0.726225E+09 | 0.00 | 0.00 |
May | 0.162248E+10 | 0.460876E+09 | 0.145120E+10 | 0.538347E+09 | 0.912849E+09 | 0.00 | 0.00 |
June | 0.186944E+10 | 0.347712E+09 | 0.154984E+10 | 0.590805E+09 | 0.959035E+09 | 0.00 | 0.00 |
July | 0.204636E+10 | 0.367181E+09 | 0.160173E+10 | 0.673138E+09 | 0.928587E+09 | 0.00 | 0.00 |
August | 0.166862E+10 | 0.400733E+09 | 0.134509E+10 | 0.536811E+09 | 0.808276E+09 | 0.00 | 0.00 |
September | 0.119315E+10 | 0.494465E+09 | 0.103166E+10 | 0.424174E+09 | 0.607482E+09 | 0.00 | 0.00 |
October | 0.761823E+09 | 0.661066E+09 | 0.765938E+09 | 0.308683E+09 | 0.457255E+09 | 0.00 | 0.00 |
November | 0.392030E+09 | 0.916130E+09 | 0.520010E+09 | 0.210688E+09 | 0.309323E+09 | 0.00 | 0.00 |
December | 0.165339E+09 | 0.141835E+10 | 0.370369E+09 | 0.124033E+09 | 0.246337E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.122360E+11 | 0.935073E+10 | 0.117018E+11 | 0.443910E+10 | 0.726269E+10 | 0.00 | 0.00 |
Minimum of Months | 0.165339E+09 | 0.347712E+09 | 0.370369E+09 | 0.124033E+09 | 0.246337E+09 | 0.00 | 0.00 |
Maximum of Months | 0.204636E+10 | 0.171472E+10 | 0.160173E+10 | 0.673138E+09 | 0.959035E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.311774E+10 | 0.200752E+11 | 0.900395E+09 | 0.369352E+09 | 0.531043E+09 | 0.00 | 0.00 |
February | 0.602708E+10 | 0.105821E+11 | 0.134738E+10 | 0.737542E+09 | 0.609838E+09 | 0.00 | 0.00 |
March | 0.123917E+11 | 0.844018E+10 | 0.245593E+10 | 0.117044E+10 | 0.128548E+10 | 0.00 | 0.00 |
April | 0.146406E+11 | 0.383237E+10 | 0.295043E+10 | 0.165146E+10 | 0.129898E+10 | 0.00 | 0.00 |
May | 0.201311E+11 | 0.261096E+10 | 0.391441E+10 | 0.223565E+10 | 0.167876E+10 | 0.00 | 0.00 |
June | 0.233945E+11 | 0.177087E+10 | 0.456284E+10 | 0.293227E+10 | 0.163057E+10 | 0.00 | 0.00 |
July | 0.240224E+11 | 0.237449E+10 | 0.488238E+10 | 0.341938E+10 | 0.146300E+10 | 0.00 | 0.00 |
August | 0.200752E+11 | 0.266148E+10 | 0.406570E+10 | 0.277477E+10 | 0.129093E+10 | 0.00 | 0.00 |
September | 0.134261E+11 | 0.266588E+10 | 0.272841E+10 | 0.173124E+10 | 0.997165E+09 | 0.00 | 0.00 |
October | 0.824334E+10 | 0.390149E+10 | 0.174803E+10 | 0.969365E+09 | 0.778670E+09 | 0.00 | 0.00 |
November | 0.436628E+10 | 0.761651E+10 | 0.101846E+10 | 0.496452E+09 | 0.522005E+09 | 0.00 | 0.00 |
December | 0.236998E+10 | 0.137236E+11 | 0.704324E+09 | 0.270494E+09 | 0.433830E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.152206E+12 | 0.802552E+11 | 0.312787E+11 | 0.187584E+11 | 0.125203E+11 | 0.00 | 0.00 |
Minimum of Months | 0.236998E+10 | 0.177087E+10 | 0.704324E+09 | 0.270494E+09 | 0.433830E+09 | 0.00 | 0.00 |
Maximum of Months | 0.240224E+11 | 0.200752E+11 | 0.488238E+10 | 0.341938E+10 | 0.167876E+10 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | -8.8 | -10.9 | -16.1 | 5.70 | -23.3 | 32.48 | 106.19 | 0.00 |
February | -2.2 | -5.0 | -9.9 | 6.21 | -16.1 | 41.31 | 158.25 | 0.00 |
March | 0.30 | -2.9 | -8.4 | 5.38 | -12.8 | 78.62 | 145.02 | 0.00 |
April | 6.67 | 2.34 | -2.9 | 4.89 | -6.2 | 82.10 | 182.32 | 0.01 |
May | 10.10 | 5.18 | 0.22 | 5.28 | -1.1 | 102.67 | 205.47 | 0.01 |
June | 16.46 | 10.06 | 4.91 | 4.56 | 5.05 | 103.05 | 264.47 | 0.02 |
July | 20.57 | 12.46 | 6.56 | 4.24 | 8.00 | 89.47 | 301.47 | 0.00 |
August | 19.17 | 11.04 | 4.61 | 4.29 | 7.19 | 78.96 | 261.05 | 0.00 |
September | 14.69 | 9.08 | 4.37 | 5.43 | 3.42 | 63.03 | 204.21 | 0.00 |
October | 8.64 | 4.13 | -1.0 | 5.38 | -4.2 | 47.64 | 162.42 | 0.00 |
November | 2.84 | -0.9 | -6.9 | 5.91 | -11.0 | 33.00 | 125.52 | 0.00 |
December | -4.1 | -6.5 | -11.1 | 5.64 | -18.2 | 26.54 | 97.81 | 0.00 |
Annual Sum or Average | 7.07 | 2.37 | -2.9 | 5.23 | -5.7 | 65.04 | 184.63 | 0.00 |
Minimum of Months | -8.8 | -10.9 | -16.1 | 4.24 | -23.3 | 26.54 | 97.81 | 0.00 |
Maximum of Months | 20.57 | 12.46 | 6.56 | 6.21 | 8.00 | 103.05 | 301.47 | 0.02 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 10.60 | 14-JAN-12:00 | 5.16 | -1.1 | 8.20 | -2.3 | 105.00 | 464.50 |
February | 18.90 | 27-FEB-14:00 | 7.23 | -7.8 | 5.20 | 1.37 | 76.00 | 634.50 |
March | 15.00 | 14-MAR-13:20 | 6.67 | -2.4 | 9.30 | 1.23 | 201.67 | 711.67 |
April | 23.30 | 07-APR-13:00 | 9.68 | -4.4 | 9.30 | 4.92 | 314.50 | 110.00 |
May | 30.00 | 20-MAY-15:00 | 15.22 | 5.60 | 6.70 | 20.57 | 215.50 | 18.50 |
June | 32.20 | 29-JUN-12:00 | 14.40 | 0.60 | 9.30 | 17.03 | 187.00 | 729.00 |
July | 37.20 | 17-JUL-15:00 | 17.28 | 4.40 | 4.60 | 20.22 | 119.50 | 797.00 |
August | 35.60 | 05-AUG-15:00 | 17.65 | 6.70 | 5.20 | 22.47 | 136.50 | 625.50 |
September | 34.40 | 02-SEP-14:00 | 16.28 | 4.40 | 7.70 | 20.75 | 95.50 | 789.50 |
October | 25.00 | 18-OCT-13:00 | 11.40 | -1.1 | 7.70 | 7.35 | 48.00 | 913.00 |
November | 17.20 | 04-NOV-13:00 | 8.18 | -1.1 | 11.30 | 2.22 | 81.00 | 689.50 |
December | 13.90 | 10-DEC-01:00 | 5.50 | -5.0 | 13.90 | 5.74 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 10.60 | 5.16 | -7.8 | 4.60 | -2.3 | 0.00 | 0.00 | |
Maximum of Months | 37.20 | 17.65 | 6.70 | 13.90 | 22.47 | 314.50 | 913.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -33.9 | 10-JAN-21:00 | -34.1 | -37.8 | 3.10 | -54.3 | 0.00 | 0.00 |
February | -25.0 | 01-FEB-03:00 | -25.2 | -27.8 | 2.10 | -45.6 | 0.00 | 0.00 |
March | -23.3 | 04-MAR-23:00 | -23.8 | -28.9 | 3.60 | -44.5 | 0.00 | 0.00 |
April | -7.8 | 29-APR-03:00 | -8.7 | -10.6 | 4.10 | -25.6 | 0.00 | 0.00 |
May | -2.8 | 08-MAY-00:10 | -3.3 | -3.9 | 6.18 | -10.2 | 0.00 | 0.00 |
June | 0.60 | 15-JUN-03:00 | -0.5 | -1.7 | 2.60 | -15.7 | 0.00 | 0.00 |
July | 5.60 | 08-JUL-03:00 | 2.99 | 0.00 | 4.10 | -9.2 | 0.00 | 0.00 |
August | 6.70 | 17-AUG-00:00 | 4.32 | 1.70 | 2.60 | -7.1 | 0.00 | 0.00 |
September | 0.00 | 17-SEP-02:00 | -1.6 | -3.9 | 4.10 | -16.8 | 0.00 | 0.00 |
October | -6.1 | 10-OCT-05:19 | -6.6 | -7.8 | 3.77 | -20.6 | 0.00 | 0.00 |
November | -16.7 | 26-NOV-07:00 | -17.3 | -20.6 | 4.60 | -33.8 | 19.50 | 94.00 |
December | -28.3 | 29-DEC-08:00 | -28.6 | -32.2 | 2.10 | -48.7 | 69.50 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -33.9 | -34.1 | -37.8 | 2.10 | -54.3 | 0.00 | 0.00 | |
Maximum of Months | 6.70 | 4.32 | 1.70 | 6.18 | -7.1 | 69.50 | 94.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 5.18 | 13-JAN-14:00 | 10.00 | 0.00 | 8.80 | -3.0 | 40.00 | 694.00 |
February | 7.23 | 27-FEB-14:00 | 18.90 | -7.8 | 5.20 | 1.37 | 76.00 | 634.50 |
March | 6.94 | 14-MAR-13:00 | 15.00 | -1.7 | 10.30 | 1.80 | 241.00 | 538.00 |
April | 11.02 | 06-APR-15:00 | 22.20 | 1.10 | 3.60 | 5.33 | 110.00 | 779.00 |
May | 15.22 | 20-MAY-15:00 | 30.00 | 5.60 | 6.70 | 20.57 | 215.50 | 18.50 |
June | 19.20 | 20-JUN-14:00 | 29.40 | 14.40 | 2.60 | 18.28 | 204.00 | 614.00 |
July | 19.21 | 19-JUL-11:00 | 29.40 | 14.40 | 8.80 | 19.52 | 306.50 | 563.50 |
August | 17.65 | 05-AUG-15:00 | 35.60 | 6.70 | 5.20 | 22.47 | 136.50 | 625.50 |
September | 20.12 | 07-SEP-15:20 | 25.17 | 17.93 | 4.10 | 15.88 | 127.67 | 652.00 |
October | 11.61 | 18-OCT-14:00 | 25.00 | -0.6 | 7.70 | 7.55 | 40.50 | 852.00 |
November | 8.89 | 17-NOV-16:00 | 17.20 | 1.10 | 11.30 | 4.10 | 0.00 | 0.00 |
December | 7.62 | 19-DEC-14:00 | 12.80 | 2.80 | 8.20 | 1.37 | 74.00 | 138.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 5.18 | 10.00 | -7.8 | 2.60 | -3.0 | 0.00 | 0.00 | |
Maximum of Months | 20.12 | 35.60 | 17.93 | 11.30 | 22.47 | 306.50 | 852.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 1.70 | 12-JAN-14:00 | 7.20 | 4.48 | 5.20 | -1.0 | 107.00 | 61.00 |
February | -0.6 | 11-FEB-08:00 | 4.40 | 2.16 | 10.80 | -5.7 | 69.50 | 50.50 |
March | -0.6 | 10-MAR-12:00 | 8.90 | 4.51 | 10.30 | -2.3 | 253.00 | 140.50 |
April | 6.10 | 17-APR-16:19 | 7.97 | 6.96 | 4.50 | 0.87 | 201.50 | 117.50 |
May | 12.20 | 02-MAY-12:00 | 18.90 | 14.61 | 12.90 | 14.84 | 108.50 | 934.50 |
June | 15.60 | 20-JUN-19:00 | 25.60 | 18.76 | 3.60 | 20.22 | 17.50 | 17.00 |
July | 16.70 | 18-JUL-21:00 | 19.40 | 17.51 | 4.10 | 16.49 | 0.00 | 0.00 |
August | 11.10 | 08-AUG-11:00 | 26.70 | 16.75 | 2.60 | 12.03 | 134.50 | 869.00 |
September | 18.30 | 07-SEP-14:00 | 24.40 | 20.10 | 4.10 | 15.57 | 111.00 | 720.00 |
October | 6.70 | 01-OCT-14:09 | 9.08 | 7.78 | 2.10 | 4.07 | 260.33 | 0.33 |
November | 3.30 | 16-NOV-19:00 | 10.60 | 6.88 | 9.80 | -1.7 | 0.00 | 0.00 |
December | 2.80 | 19-DEC-14:09 | 10.97 | 6.81 | 10.78 | -1.0 | 95.00 | 292.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -0.6 | 4.40 | 2.16 | 2.10 | -5.7 | 0.00 | 0.00 | |
Maximum of Months | 18.30 | 26.70 | 20.10 | 12.90 | 20.22 | 260.33 | 934.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 5.41 | 12.59 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 4.46 | 20.37 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 5.03 | 30.19 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 7.01 | 37.07 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 9.90 | 46.35 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 12.91 | 55.45 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 15.24 | 57.38 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 16.26 | 48.01 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 15.67 | 34.51 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 13.64 | 22.84 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 10.74 | 14.52 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 7.74 | 10.24 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 10.37 | 32.53 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 4.46 | 10.24 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 16.26 | 57.38 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.102857E+10 | -957260268.5 | 0.00 | 0.00 | 744.00 | 0.00 | -71312696.6 | 59.00 | 0.00 | 0.00 |
February | 0.958936E+09 | -894739592.8 | 0.00 | 0.00 | 672.00 | 0.00 | -64196118.1 | 58.99 | 0.00 | 0.00 |
March | 0.110562E+10 | -0.103489E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -70733285.1 | 58.99 | 0.00 | 0.00 |
April | 0.993852E+09 | -926357274.7 | 0.00 | 0.00 | 720.00 | 0.00 | -67494318.7 | 58.99 | 0.00 | 0.00 |
May | 0.977764E+09 | -910526821.2 | 0.00 | 0.00 | 744.00 | 0.00 | -67237563.4 | 58.99 | 0.00 | 0.00 |
June | 0.911001E+09 | -851144236.5 | 0.00 | 0.00 | 720.00 | 0.00 | -59856994.3 | 58.99 | 0.00 | 0.00 |
July | 0.839219E+09 | -780871447.2 | 0.00 | 0.00 | 744.00 | 0.00 | -58347068.3 | 59.01 | 0.00 | 0.00 |
August | 0.878949E+09 | -819662080.3 | 0.00 | 0.00 | 744.00 | 0.00 | -59287127.0 | 58.99 | 0.00 | 0.00 |
September | 0.833201E+09 | -772499933.5 | 0.00 | 0.00 | 720.00 | 0.00 | -60701152.0 | 59.00 | 0.00 | 0.00 |
October | 0.878521E+09 | -810516104.4 | 0.00 | 0.00 | 744.00 | 0.00 | -68004884.2 | 58.99 | 0.00 | 0.00 |
November | 0.895849E+09 | -827637188.0 | 0.00 | 0.00 | 720.00 | 0.00 | -68212290.4 | 58.99 | 0.00 | 0.00 |
December | 0.985817E+09 | -914633461.1 | 0.00 | 0.00 | 744.00 | 0.00 | -71183598.3 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.112873E+11 | -0.105007E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -786567096.3 | 58.99 | 0.00 | 0.00 |
Minimum of Months | 0.833201E+09 | -0.103489E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -71312696.6 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.110562E+10 | -772499933.5 | 0.00 | 0.00 | 744.00 | 0.00 | -58347068.3 | 59.01 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: ZONE3 BULK STORAGE_DAYLCTRL
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 226.83 | 0.95 | 0.88 | 04-JAN-11:09 | 125.41 | 8.90 | 0.00 | 41.83 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 275.00 | 0.95 | 0.88 | 03-FEB-10:00 | 132.21 | 9.38 | 0.00 | 44.33 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 304.00 | 0.92 | 0.88 | 02-MAR-08:00 | 245.44 | 12.40 | 0.00 | 179.67 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 325.17 | 0.92 | 0.88 | 01-APR-09:09 | 256.14 | 12.35 | 0.00 | 195.67 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 385.83 | 0.91 | 0.88 | 01-MAY-08:09 | 1141.27 | 13.54 | 18.67 | 275.67 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 434.17 | 0.92 | 0.88 | 01-JUN-13:39 | 3554.87 | 14.66 | 51.33 | 282.83 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 417.33 | 0.91 | 0.88 | 01-JUL-07:10 | 2802.66 | 14.27 | 34.33 | 267.33 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 421.33 | 0.92 | 0.88 | 01-AUG-08:00 | 235.60 | 11.80 | 0.00 | 201.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 352.17 | 0.93 | 0.88 | 02-SEP-16:10 | 190.73 | 11.05 | 0.00 | 131.83 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 317.67 | 0.94 | 0.88 | 01-OCT-12:39 | 150.04 | 9.80 | 0.00 | 77.83 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 269.50 | 0.96 | 0.88 | 01-NOV-10:09 | 114.25 | 8.51 | 0.00 | 31.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 236.83 | 0.97 | 0.88 | 04-DEC-10:50 | 95.20 | 7.68 | 0.00 | 13.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3965.83 | 0.93 | 918.73 | 11.60 | 104.33 | 1742.67 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 226.83 | 0.91 | 0.88 | 95.20 | 7.68 | 0.00 | 13.67 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 434.17 | 0.97 | 0.88 | 3554.87 | 14.66 | 51.33 | 282.83 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: ZONE1 OFFICE_DAYLCTRL
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 226.83 | 0.92 | 0.82 | 30-JAN-15:20 | 184.17 | 20.07 | 89.67 | 4.33 | 102.44 | 20.07 | 83.83 | 0.00 |
February | 275.00 | 0.90 | 0.80 | 21-FEB-15:30 | 292.10 | 22.74 | 137.50 | 36.83 | 126.02 | 20.93 | 119.67 | 0.00 |
March | 304.00 | 0.86 | 0.80 | 01-MAR-15:09 | 468.93 | 24.48 | 208.50 | 106.17 | 352.15 | 25.02 | 233.83 | 50.67 |
April | 325.17 | 0.87 | 0.80 | 01-APR-15:09 | 429.95 | 22.76 | 189.33 | 107.83 | 455.25 | 23.87 | 223.33 | 72.50 |
May | 385.83 | 0.86 | 0.80 | 01-MAY-14:00 | 347.59 | 21.97 | 226.17 | 133.17 | 570.85 | 23.12 | 271.17 | 98.83 |
June | 434.17 | 0.86 | 0.80 | 01-JUN-14:20 | 337.45 | 21.68 | 235.83 | 150.00 | 316.01 | 22.91 | 303.00 | 101.33 |
July | 417.33 | 0.86 | 0.80 | 01-JUL-14:39 | 346.05 | 22.02 | 228.00 | 147.17 | 478.06 | 23.14 | 284.33 | 110.83 |
August | 421.33 | 0.87 | 0.80 | 01-AUG-14:20 | 337.61 | 21.64 | 207.67 | 114.33 | 448.62 | 22.78 | 255.17 | 90.83 |
September | 352.17 | 0.88 | 0.80 | 01-SEP-15:09 | 510.73 | 23.67 | 186.83 | 96.17 | 449.80 | 24.77 | 215.17 | 58.67 |
October | 317.67 | 0.89 | 0.80 | 02-OCT-14:39 | 499.07 | 24.38 | 173.83 | 65.50 | 197.21 | 23.11 | 175.33 | 21.17 |
November | 269.50 | 0.91 | 0.82 | 01-NOV-15:20 | 280.66 | 23.23 | 129.17 | 29.67 | 104.47 | 20.14 | 100.33 | 0.00 |
December | 236.83 | 0.92 | 0.83 | 04-DEC-14:30 | 193.31 | 22.06 | 96.33 | 13.67 | 85.72 | 19.44 | 57.17 | 0.00 |
Annual Sum or Average | 3965.83 | 0.88 | 360.97 | 22.55 | 2108.83 | 1004.83 | 334.98 | 22.67 | 2322.33 | 604.83 | ||
Minimum of Months | 226.83 | 0.86 | 0.80 | 184.17 | 20.07 | 89.67 | 4.33 | 85.72 | 19.44 | 57.17 | 0.00 | |
Maximum of Months | 434.17 | 0.92 | 0.83 | 510.73 | 24.48 | 235.83 | 150.00 | 570.85 | 25.02 | 303.00 | 110.83 |
Report: CoilReportMonthly
For: PSZ-OFFICE HEATING COIL
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.127341E+11 | 27439.48 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.820454E+10 | 27439.48 | 01-FEB-06:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.709660E+10 | 27439.48 | 01-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.340744E+10 | 27439.48 | 01-APR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.231243E+10 | 27439.48 | 01-MAY-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 96758257.61 | 17103.01 | 17-JUN-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 11024727.26 | 9112.39 | 18-AUG-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.513933E+09 | 27439.48 | 18-SEP-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.176979E+10 | 27439.48 | 02-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.512425E+10 | 27439.48 | 01-NOV-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.921576E+10 | 27439.48 | 01-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.504866E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.127341E+11 | 27439.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE HEATING COIL
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.466651E+11 | 69620.04 | 01-JAN-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.280807E+11 | 69620.04 | 01-FEB-00:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.220339E+11 | 69620.04 | 02-MAR-21:33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.814924E+10 | 69620.04 | 15-APR-02:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.418024E+10 | 69620.04 | 07-MAY-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.324246E+09 | 26624.96 | 20-SEP-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.287797E+10 | 58712.75 | 10-OCT-04:53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.168419E+11 | 69620.04 | 12-NOV-00:53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.340221E+11 | 69620.04 | 01-DEC-02:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.163175E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.466651E+11 | 69620.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.144784E+12 | 131493.17 | 05-JAN-12:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.767408E+11 | 100022.74 | 03-FEB-19:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.526650E+11 | 103342.01 | 04-MAR-01:53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.657674E+10 | 47715.70 | 29-APR-04:52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.583242E+10 | 44536.24 | 08-MAY-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.124095E+09 | 10115.41 | 11-OCT-05:57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.361939E+11 | 88772.98 | 27-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.944195E+11 | 131493.17 | 27-DEC-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.417336E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.144784E+12 | 131493.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.241121E+09 | 0.240735E+09 | 5114.45 | 19-MAY-16:00 | 5114.45 | 0.00 |
June | 0.00 | 0.00 | 0.206182E+10 | 0.198183E+10 | 17562.48 | 24-JUN-07:02 | 13578.47 | 0.00 |
July | 0.00 | 0.00 | 0.487971E+10 | 0.473809E+10 | 19446.42 | 19-JUL-07:02 | 13157.60 | 0.00 |
August | 0.00 | 0.00 | 0.392756E+10 | 0.390082E+10 | 17591.07 | 09-AUG-07:02 | 16290.68 | 0.00 |
September | 0.00 | 0.00 | 0.133873E+10 | 0.123469E+10 | 17334.02 | 05-SEP-07:02 | 15436.82 | 0.00 |
October | 0.00 | 0.00 | 31077022.16 | 31077022.16 | 2951.66 | 18-OCT-16:00 | 2951.66 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.124800E+11 | 0.121272E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.487971E+10 | 0.473809E+10 | 19446.42 | 16290.68 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.770959E+09 | 0.762964E+09 | 18414.00 | 30-JUN-17:33 | 18414.00 | 0.00 |
July | 0.00 | 0.00 | 0.451414E+10 | 0.443085E+10 | 39468.89 | 16-JUL-11:05 | 34260.01 | 0.00 |
August | 0.00 | 0.00 | 0.337343E+10 | 0.336490E+10 | 37117.76 | 08-AUG-19:55 | 37117.76 | 0.00 |
September | 0.00 | 0.00 | 0.929638E+09 | 0.866347E+09 | 25289.15 | 03-SEP-15:35 | 25289.15 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.958817E+10 | 0.942506E+10 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.451414E+10 | 0.443085E+10 | 39468.89 | 37117.76 | 0.00 |
Report: FanReportMonthly
For: ZONE3UNITHEATER ZONE3HIRADIANT FAN
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.886053E+09 | 0.08 | 341.29 | 01-JAN-00:03 | 0.09 |
February | 0.696092E+09 | 0.07 | 341.29 | 01-FEB-00:02 | 0.09 |
March | 0.668826E+09 | 0.06 | 341.29 | 01-MAR-00:10 | 0.09 |
April | 0.183688E+09 | 0.02 | 341.29 | 01-APR-00:10 | 0.09 |
May | 0.116430E+09 | 0.01 | 341.29 | 01-MAY-00:03 | 0.09 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 |
October | 7576599.66 | 0.00 | 341.29 | 11-OCT-01:10 | 0.09 |
November | 0.392174E+09 | 0.04 | 341.29 | 10-NOV-04:17 | 0.09 |
December | 0.812515E+09 | 0.08 | 341.29 | 01-DEC-00:03 | 0.09 |
Annual Sum or Average | 0.376336E+10 | 0.03 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.886053E+09 | 0.08 | 341.29 | 0.09 |
Report: FanReportMonthly
For: PSZ-OFFICE_ADDAQ SUPPLY FAN
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.135961E+10 | 0.76 | 1224.17 | 02-JAN-07:40 | 1.04 |
February | 0.119426E+10 | 0.66 | 1224.17 | 01-FEB-14:00 | 1.04 |
March | 0.136091E+10 | 0.58 | 1224.17 | 01-MAR-07:20 | 1.04 |
April | 0.122710E+10 | 0.44 | 1224.17 | 01-APR-06:50 | 1.04 |
May | 0.127425E+10 | 0.44 | 1224.17 | 01-MAY-06:10 | 1.04 |
June | 0.126041E+10 | 0.41 | 1224.17 | 02-JUN-06:05 | 1.03 |
July | 0.121211E+10 | 0.38 | 1224.17 | 01-JUL-08:00 | 1.03 |
August | 0.130889E+10 | 0.41 | 1224.17 | 01-AUG-07:30 | 1.03 |
September | 0.121287E+10 | 0.40 | 1224.17 | 01-SEP-15:40 | 1.03 |
October | 0.121694E+10 | 0.40 | 1224.17 | 02-OCT-07:00 | 1.04 |
November | 0.120304E+10 | 0.50 | 1224.17 | 01-NOV-06:08 | 1.04 |
December | 0.130645E+10 | 0.67 | 1224.17 | 01-DEC-07:08 | 1.04 |
Annual Sum or Average | 0.151368E+11 | 0.50 | |||
Minimum of Months | 0.119426E+10 | 0.38 | 1224.17 | 1.03 | |
Maximum of Months | 0.136091E+10 | 0.76 | 1224.17 | 1.04 |
Report: FanReportMonthly
For: PSZ-FINE STORAGE_ADDAQ SUPPLY FAN
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.197826E+10 | 0.71 | 2077.41 | 01-JAN-06:03 | 1.01 |
February | 0.146847E+10 | 0.66 | 2077.41 | 01-FEB-00:02 | 1.01 |
March | 0.146175E+10 | 0.63 | 2077.41 | 02-MAR-21:33 | 1.00 |
April | 0.104024E+10 | 0.48 | 2077.41 | 15-APR-02:62 | 1.01 |
May | 0.967949E+09 | 0.34 | 2077.41 | 07-MAY-05:03 | 1.00 |
June | 0.856099E+09 | 0.24 | 877.42 | 30-JUN-17:33 | 0.63 |
July | 0.856963E+09 | 0.24 | 2077.41 | 15-JUL-17:10 | 0.99 |
August | 0.916189E+09 | 0.26 | 2077.41 | 07-AUG-17:08 | 1.00 |
September | 0.844172E+09 | 0.25 | 1435.35 | 03-SEP-15:35 | 0.84 |
October | 0.899334E+09 | 0.31 | 1860.45 | 11-OCT-06:02 | 0.96 |
November | 0.123214E+10 | 0.57 | 2077.41 | 12-NOV-00:53 | 1.01 |
December | 0.168594E+10 | 0.68 | 2077.41 | 01-DEC-02:62 | 1.01 |
Annual Sum or Average | 0.142075E+11 | 0.45 | |||
Minimum of Months | 0.844172E+09 | 0.24 | 877.42 | 0.63 | |
Maximum of Months | 0.197826E+10 | 0.71 | 2077.41 | 1.01 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-OFFICE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.135961E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.119426E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.136091E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.122710E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.132744E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.170434E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.226621E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.215994E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.149624E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.122372E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.120304E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.130645E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.178293E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.119426E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.226621E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.197826E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.146847E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.146175E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.104024E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.967949E+09 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.106472E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.204780E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.181063E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.109082E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.899334E+09 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.123214E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.168594E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.167481E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.899334E+09 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.204780E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-OFFICE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.135961E+10 | 0.00 | 0.127341E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.119426E+10 | 0.00 | 0.820454E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.136091E+10 | 0.00 | 0.709660E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.122710E+10 | 0.00 | 0.340744E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.127425E+10 | 0.241121E+09 | 0.231243E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.126041E+10 | 0.206182E+10 | 96758257.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.121211E+10 | 0.487971E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.130889E+10 | 0.392756E+10 | 11024727.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.121287E+10 | 0.133873E+10 | 0.513933E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.121694E+10 | 31077022.16 | 0.176979E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.120304E+10 | 0.00 | 0.512425E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.130645E+10 | 0.00 | 0.921576E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.151368E+11 | 0.124800E+11 | 0.504866E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.119426E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.136091E+10 | 0.487971E+10 | 0.127341E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-FINE STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.197826E+10 | 0.00 | 0.466651E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.146847E+10 | 0.00 | 0.280807E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.146175E+10 | 0.00 | 0.220339E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.104024E+10 | 0.00 | 0.814924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.967949E+09 | 0.00 | 0.418024E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.856099E+09 | 0.770959E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.856963E+09 | 0.446826E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.916189E+09 | 0.335858E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.844172E+09 | 0.929638E+09 | 0.324246E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.899334E+09 | 0.00 | 0.287797E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.123214E+10 | 0.00 | 0.168419E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.168594E+10 | 0.00 | 0.340221E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.142075E+11 | 0.952744E+10 | 0.163175E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.844172E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.197826E+10 | 0.446826E+10 | 0.466651E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-OFFICE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.135961E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.119426E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.136091E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.122710E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.127425E+10 | 0.00 | 0.00 | 0.00 | 53186513.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.126041E+10 | 0.00 | 0.00 | 0.00 | 0.443928E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.121211E+10 | 0.00 | 0.00 | 0.00 | 0.105409E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.130889E+10 | 0.00 | 0.00 | 0.00 | 0.851051E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.121287E+10 | 0.00 | 0.00 | 0.00 | 0.283374E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.121694E+10 | 0.00 | 0.00 | 0.00 | 6782259.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.120304E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.130645E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.151368E+11 | 0.00 | 0.00 | 0.00 | 0.269241E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.119426E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.136091E+10 | 0.00 | 0.00 | 0.00 | 0.105409E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.197826E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.146847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.146175E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.104024E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.967949E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.856099E+09 | 0.00 | 0.00 | 0.00 | 0.208620E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.856963E+09 | 0.00 | 0.00 | 0.00 | 0.119084E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.916189E+09 | 0.00 | 0.00 | 0.00 | 0.894444E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.844172E+09 | 0.00 | 0.00 | 0.00 | 0.246651E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.899334E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.123214E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.168594E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.142075E+11 | 0.00 | 0.00 | 0.00 | 0.254055E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.844172E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.197826E+10 | 0.00 | 0.00 | 0.00 | 0.119084E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 386881.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.298776E+10 | 0.00 | 0.00 | 0.12 |
February | 22239469.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.212013E+10 | 0.00 | 0.00 | 0.13 |
March | 7083045.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.208440E+10 | 0.00 | 0.00 | 0.13 |
April | 0.176345E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121844E+10 | 0.00 | 0.00 | 0.13 |
May | 0.345617E+09 | 449954.95 | 717239.02 | 243527.52 | 982014.07 | 0.821935E+09 | 0.163376E+09 | 5973.72 | 0.19 |
June | 0.307300E+09 | 58881182.52 | 0.00 | 1922586.68 | 0.00 | 21493993.53 | 0.121820E+10 | 0.00 | 0.41 |
July | 17373272.05 | 0.138376E+09 | 0.00 | 4149267.14 | 1228.72 | 0.00 | 0.134025E+10 | 0.00 | 0.45 |
August | 81423789.02 | 92692013.68 | 0.00 | 3729282.43 | 0.00 | 5425984.85 | 0.163535E+10 | 0.00 | 0.52 |
September | 0.390551E+09 | 39524316.12 | 0.00 | 1720651.58 | 0.00 | 0.204001E+09 | 0.966612E+09 | 0.00 | 0.34 |
October | 0.519084E+09 | 0.00 | 0.00 | 33523.54 | 0.00 | 0.705429E+09 | 59258604.37 | 0.00 | 0.14 |
November | 75906788.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.158435E+10 | 0.00 | 0.00 | 0.12 |
December | 921046.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.247449E+10 | 0.00 | 0.00 | 0.12 |
Annual Sum or Average | 0.194423E+10 | 0.329924E+09 | 717239.02 | 11798838.89 | 983242.79 | 0.142279E+11 | 0.538305E+10 | 5973.72 | 0.23 |
Minimum of Months | 386881.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.12 |
Maximum of Months | 0.519084E+09 | 0.138376E+09 | 717239.02 | 4149267.14 | 982014.07 | 0.298776E+10 | 0.163535E+10 | 5973.72 | 0.52 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.321436E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.939385E+10 | 0.00 | 0.00 | 0.17 |
February | 0.109444E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.538493E+10 | 0.00 | 0.00 | 0.17 |
March | 0.237730E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.351621E+10 | 0.00 | 0.00 | 0.19 |
April | 0.249681E+10 | 0.00 | 0.00 | 0.00 | 7278629.25 | 0.103540E+10 | 0.00 | 0.00 | 0.18 |
May | 0.263496E+10 | 0.00 | 0.00 | 0.00 | 35479533.84 | 0.442218E+09 | 0.00 | 0.00 | 0.18 |
June | 0.232611E+10 | 21359642.33 | 0.00 | 553227.13 | 33950554.75 | 0.00 | 0.156982E+09 | 0.00 | 0.19 |
July | 0.125171E+10 | 0.173585E+09 | 0.00 | 2930475.33 | 0.00 | 0.00 | 0.104673E+10 | 0.00 | 0.22 |
August | 0.196399E+10 | 0.112481E+09 | 0.00 | 1569376.53 | 0.00 | 0.00 | 0.585033E+09 | 0.00 | 0.22 |
September | 0.242824E+10 | 29476783.38 | 0.00 | 684548.08 | 6365009.37 | 44648005.69 | 0.228719E+09 | 0.00 | 0.20 |
October | 0.284580E+10 | 0.00 | 0.00 | 0.00 | 12831382.14 | 0.268466E+09 | 0.00 | 0.00 | 0.17 |
November | 0.204281E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.245298E+10 | 0.00 | 0.00 | 0.17 |
December | 0.893303E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.669193E+10 | 0.00 | 0.00 | 0.17 |
Annual Sum or Average | 0.226769E+11 | 0.336902E+09 | 0.00 | 5737627.08 | 95905109.36 | 0.292306E+11 | 0.201747E+10 | 0.00 | 0.19 |
Minimum of Months | 0.321436E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 |
Maximum of Months | 0.284580E+10 | 0.173585E+09 | 0.00 | 2930475.33 | 35479533.84 | 0.939385E+10 | 0.104673E+10 | 0.00 | 0.22 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 10:43:55
Custom Monthly ReportSITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
January | 0.217912E+12 | 0.139223E+12 | 0.00 | 0.127034E+11 | 0.604141E+11 |
February | 0.381729E+12 | 0.835513E+11 | 0.00 | 0.862174E+10 | 0.348501E+11 |
March | 0.720533E+12 | 0.752019E+11 | 0.00 | 0.798499E+10 | 0.261557E+11 |
April | 0.795339E+12 | 0.352820E+11 | 0.00 | 0.491971E+10 | 0.712716E+10 |
May | 0.109641E+13 | 0.321128E+11 | 0.00 | 0.437072E+10 | 0.476572E+10 |
June | 0.123188E+13 | 0.267526E+11 | 0.00 | 0.391838E+10 | 0.353351E+10 |
July | 0.126061E+13 | 0.271204E+11 | 0.00 | 0.335112E+10 | 0.116388E+11 |
August | 0.105374E+13 | 0.368067E+11 | 0.00 | 0.407277E+10 | 0.905227E+10 |
September | 0.748933E+12 | 0.431683E+11 | 0.00 | 0.418981E+10 | 0.321029E+10 |
October | 0.447602E+12 | 0.383656E+11 | 0.00 | 0.438524E+10 | 0.228190E+10 |
November | 0.205174E+12 | 0.622305E+11 | 0.00 | 0.615605E+10 | 0.188729E+11 |
December | 0.110799E+12 | 0.984043E+11 | 0.00 | 0.100606E+11 | 0.422301E+11 |
Annual Sum or Average | 0.827065E+13 | 0.698219E+12 | 0.00 | 0.747346E+11 | 0.224133E+12 |
Minimum of Months | 0.110799E+12 | 0.267526E+11 | 0.00 | 0.335112E+10 | 0.228190E+10 |
Maximum of Months | 0.126061E+13 | 0.139223E+12 | 0.00 | 0.127034E+11 | 0.604141E+11 |