Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 10:43
Tabular Output Report in Format: HTML
Building: Warehouse
Environment: RUNPERIOD 1 ** Buffalo Niagara Intl AP NY USA TMY3 WMO#=725280
Simulation Timestamp: 2023-10-16 10:44:03
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1055.30 | 218.26 | 218.26 |
Net Site Energy | 1055.30 | 218.26 | 218.26 |
Total Source Energy | 1887.71 | 390.41 | 390.41 |
Net Source Energy | 1887.71 | 390.41 | 390.41 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 1.200 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil No 1 | 1.050 |
Fuel Oil No 2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4835.13 |
Net Conditioned Building Area | 4835.13 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 698.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 10.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 93.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 61.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 136.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 29.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 26.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 357.06 | 698.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 698.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 10.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 93.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 61.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 136.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 29.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 26.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Unassigned | 0.00 | 698.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | Unassigned | 10.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GENERAL | 93.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | Unassigned | 61.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | GENERAL | 136.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Unassigned | 29.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Unassigned | 26.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 32.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 13.58 | 144.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 73.85 | 144.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 32.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 13.58 | 144.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 73.85 | 144.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 357.062 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 357.062 | 100.00 |
Total On-Site and Utility Electric Sources | 357.062 | 100.00 |
Total Electricity End Uses | 357.062 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 51.61 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 51.61 | 100.00 |
Total Water End Uses | 51.61 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 28.50 |
Time Setpoint Not Met During Occupied Cooling | 0.17 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 3083.50 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2021
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5A
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_NY_BUFFALO
| Environment |ZoneCoolingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneHeatingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneElectricSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |PeakSpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainComponentsAtCoolingPeakMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ComfortReportSimple55Monthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |OccupantComfortDataSummaryMonthly
| OFFICE PEOPLE | ZONE2 FINE STORAGEPEOPLE | ZONE3 BULK STORAGEPEOPLE |DXReportMonthly
| PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |WindowReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | FINESTORAGE_SKYLIGHT_1 | FINESTORAGE_SKYLIGHT_6 | FINESTORAGE_SKYLIGHT_7 | FINESTORAGE_SKYLIGHT_8 | FINESTORAGE_SKYLIGHT_9 | FINESTORAGE_SKYLIGHT_10 | FINESTORAGE_SKYLIGHT_5 | FINESTORAGE_SKYLIGHT_4 | FINESTORAGE_SKYLIGHT_3 | FINESTORAGE_SKYLIGHT_2 | FINESTORAGE_SKYLIGHT_14 | FINESTORAGE_SKYLIGHT_13 | FINESTORAGE_SKYLIGHT_12 | FINESTORAGE_SKYLIGHT_11 | SKYLIGHT_R8C1 | SKYLIGHT_R8C2 | SKYLIGHT_R8C4 | SKYLIGHT_R1C2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C4 | SKYLIGHT_R1C3 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R3C4 | SKYLIGHT_R3C2 | SKYLIGHT_R3C3 | SKYLIGHT_R3C1 | SKYLIGHT_R4C4 | SKYLIGHT_R4C3 | SKYLIGHT_R4C2 | SKYLIGHT_R4C1 | SKYLIGHT_R5C4 | SKYLIGHT_R5C1 | SKYLIGHT_R5C3 | SKYLIGHT_R5C2 | SKYLIGHT_R6C1 | SKYLIGHT_R6C2 | SKYLIGHT_R8C3 | SKYLIGHT_R6C4 | SKYLIGHT_R7C1 | SKYLIGHT_R7C2 | SKYLIGHT_R7C4 | SKYLIGHT_R6C3 | SKYLIGHT_R7C3 |WindowEnergyReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | FINESTORAGE_SKYLIGHT_1 | FINESTORAGE_SKYLIGHT_6 | FINESTORAGE_SKYLIGHT_7 | FINESTORAGE_SKYLIGHT_8 | FINESTORAGE_SKYLIGHT_9 | FINESTORAGE_SKYLIGHT_10 | FINESTORAGE_SKYLIGHT_5 | FINESTORAGE_SKYLIGHT_4 | FINESTORAGE_SKYLIGHT_3 | FINESTORAGE_SKYLIGHT_2 | FINESTORAGE_SKYLIGHT_14 | FINESTORAGE_SKYLIGHT_13 | FINESTORAGE_SKYLIGHT_12 | FINESTORAGE_SKYLIGHT_11 | SKYLIGHT_R8C1 | SKYLIGHT_R8C2 | SKYLIGHT_R8C4 | SKYLIGHT_R1C2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C4 | SKYLIGHT_R1C3 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R3C4 | SKYLIGHT_R3C2 | SKYLIGHT_R3C3 | SKYLIGHT_R3C1 | SKYLIGHT_R4C4 | SKYLIGHT_R4C3 | SKYLIGHT_R4C2 | SKYLIGHT_R4C1 | SKYLIGHT_R5C4 | SKYLIGHT_R5C1 | SKYLIGHT_R5C3 | SKYLIGHT_R5C2 | SKYLIGHT_R6C1 | SKYLIGHT_R6C2 | SKYLIGHT_R8C3 | SKYLIGHT_R6C4 | SKYLIGHT_R7C1 | SKYLIGHT_R7C2 | SKYLIGHT_R7C4 | SKYLIGHT_R6C3 | SKYLIGHT_R7C3 |WindowZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |WindowEnergyZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWHSYS1 WATER HEATER |DaylightingReportMonthly
| ZONE2 FINE STORAGE_DAYLCTRL | ZONE3 BULK STORAGE_DAYLCTRL | ZONE1 OFFICE_DAYLCTRL |CoilReportMonthly
| PSZ-OFFICE HEATING COIL | PSZ-FINE STORAGE HEATING COIL | ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |FanReportMonthly
| ZONE3UNITHEATER ZONE3HIRADIANT FAN | PSZ-OFFICE_ADDAQ SUPPLY FAN | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN |ZoneTemperatureOscillationReportMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentLoadsMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentEnergyUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |MechanicalVentilationLoadsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
GeneralValue | |
Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 10:43 |
RunPeriod | RUNPERIOD 1 |
Weather File | Buffalo Niagara Intl AP NY USA TMY3 WMO#=725280 |
Latitude [deg] | 42.93 |
Longitude [deg] | -78.7 |
Elevation [m] | 215.00 |
Time Zone | -5.0 |
North Axis Angle [deg] | 90.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | |
Gross Roof Area [m2] | 4598.25 |
Skylight Area [m2] | 68.38 |
Skylight-Roof Ratio [%] | 1.49 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
ZONE1 OFFICE | 236.88 | Yes | Yes | 1010.76 | 1.00 | 149.56 | 0.00 | 17.66 | 17.66 | 6.0858 | 18.58 | 8.0737 |
ZONE2 FINE STORAGE | 1393.41 | Yes | Yes | 2953.02 | 1.00 | 760.80 | 0.00 | 0.00 | 0.00 | 6.6844 | 46.45 | 0.0000 |
ZONE3 BULK STORAGE | 3204.84 | Yes | Yes | 35277.63 | 1.00 | 1586.63 | 0.00 | 0.00 | 0.00 | 3.1969 | 46.45 | 2.5587 |
Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 4.3435 | 43.27 | 2.0915 | |||
Conditioned Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 4.3435 | 43.27 | 2.0915 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
ZONE1 OFFICE | 236.88 | Yes | Yes | 1.00 | ZONE1 OFFICE | GENERAL | ZONE1 OFFICE | 6.0858 | 18.58 | 8.0737 | |
ZONE2 FINE STORAGE | 1393.41 | Yes | Yes | 1.00 | ZONE2 FINE STORAGE | GENERAL | ZONE2 FINE STORAGE | 6.6844 | 46.45 | 0.0000 | |
ZONE3 BULK STORAGE | 3204.84 | Yes | Yes | 1.00 | ZONE3 BULK STORAGE | GENERAL | ZONE3 BULK STORAGE | 3.1969 | 46.45 | 2.5587 | |
Total | 4835.13 | 4.3435 | 21.63 | 2.0915 | |||||||
Conditioned Total | 4835.13 | 4.3435 | 21.63 | 2.0915 | |||||||
Unconditioned Total | 0.00 | 0.0000 | 0.00 | 0.0000 | |||||||
Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
GENERAL | 4835.13 | 4835.13 | 0.00 | 0.00 | 4.3435 | 43.27 | 2.0915 |
Total | 4835.13 | 4835.13 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
End UsesElectricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 19-JUL-14:50 | 06-FEB-17:19 | - | - | - | - | - | - | - | - | - | - | 02-JAN-12:09 |
Heating | 0.00 | 237586.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 9215.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 5065.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10035.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 4291.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1759.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 30366.73 | 237586.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 237586.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 9215.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 5065.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10035.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 1986.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 1759.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 756.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 31.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 295.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 195.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 432.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 93.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 82.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1130.81 | 756.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 156.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 6.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 61.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 40.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 89.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 19.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 17.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 233.87 | 156.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 156.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 6.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 61.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 40.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 89.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 19.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 17.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 233.87 | 156.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
AirTerminal:SingleDuct:ConstantVolume:NoReheatDesign Size Maximum Air Flow Rate [m3/s] | |
ZONE1 OFFICE DIRECT AIR | 0.949635 |
ZONE2 FINE STORAGE DIRECT AIR | 2.02 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
ZONE3 BULK STORAGE UNIT HEATER | 3.32 |
Design Size Maximum Flow Rate [m3/s] | |
ZONE3UNITHEATER ZONE3HIRADIANT FAN | 3.32 |
Design Size Nominal Capacity [W] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | 132540.27 |
PSZ-OFFICE HEATING COIL | 25733.53 |
PSZ-FINE STORAGE HEATING COIL | 74279.25 |
User-Specified Heating Design Capacity [W] | |
ZONE3 BULK STORAGE HIRADIANT | 132540.27 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-OFFICE | 0.949635 | 0.949635 | 0.949635 | 0.949635 | 0.949635 | 0.949635 | 1.00 | 1.000000 | 0.949635 |
PSZ-FINE STORAGE | 2.02 | 2.02 | 2.02 | 2.02 | 2.02 | 2.02 | 1.00 | 1.00 | 2.02 |
Maximum Outdoor Air Flow Rate [m3/s] | |
PSZ-OFFICE_OA_CONTROLLER | 0.949635 |
PSZ-FINE STORAGE_OA_CONTROLLER | 2.02 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-OFFICE_ADDAQ SUPPLY FAN | 0.949635 | 1051.40 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | 2.02 | 2164.29 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-OFFICE_UNITARY_PACKAGE_DX | 0.949635 | 0.949635 | 0.949635 | 0.949635 | 17377.41 | 25733.53 | 40.00 | 1.00 |
PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | 2.02 | 2.02 | 2.02 | 1.33 | 47300.86 | 74279.25 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | User-Specified Speed 2 Rated Sensible Heat Ratio | User-Specified Speed 1 Rated Sensible Heat Ratio | |
PSZ-OFFICE COOLING COIL | 0.949630 | 0.474817 | 0.633087 | 17377.41 | 8688.70 | 0.800590 | 0.800590 |
PSZ-FINE STORAGE COOLING COIL | 2.02 | 1.01 | 1.35 | 47300.86 | 23650.43 | 0.720240 | 0.720240 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
OFFICE FRONT WALL | OFFICE FRONT DOOR | OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | |
OFFICE LEFT WALL | OFFICE LEFT WALL DOOR | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | |
FINE STORAGE FRONT WALL | FINE STORAGE OVERHEAD DOOR1 | |
FINE STORAGE RIGHT WALL | FINE STORAGE OVERHEAD DOOR2 | FINE STORAGE OVERHEAD DOOR3 | FINE STORAGE RIGHT DOOR | |
FINE STORAGE LEFT WALL | FINE STORAGE OVERHEAD DOOR4 | FINE STORAGE LEFT DOOR | |
FINE STORAGE ROOF | FINESTORAGE_SKYLIGHT_1 | FINESTORAGE_SKYLIGHT_6 | FINESTORAGE_SKYLIGHT_7 | FINESTORAGE_SKYLIGHT_8 | FINESTORAGE_SKYLIGHT_9 | FINESTORAGE_SKYLIGHT_10 | FINESTORAGE_SKYLIGHT_5 | FINESTORAGE_SKYLIGHT_4 | FINESTORAGE_SKYLIGHT_3 | FINESTORAGE_SKYLIGHT_2 | FINESTORAGE_SKYLIGHT_14 | FINESTORAGE_SKYLIGHT_13 | FINESTORAGE_SKYLIGHT_12 | FINESTORAGE_SKYLIGHT_11 | |
BULK STORAGE RIGHT WALL | BULK STORAGE OVERHEAD DOOR8 | BULK STORAGE OVERHEAD DOOR9 | BULK STORAGE OVERHEAD DOOR10 | BULK STORAGE OVERHEAD DOOR11 | BULK STORAGE DOOR1 | BULK STORAGE DOOR2 | BULK STORAGE DOOR3 | |
BULK STORAGE REAR WALL | BULK STORAGE OVERHEAD DOOR12 | BULK STORAGE OVERHEAD DOOR13 | BULK STORAGE OVERHEAD DOOR14 | BULK STORAGE OVERHEAD DOOR15 | BULK STORAGE DOOR4 | |
BULK STORAGE LEFT WALL | BULK STORAGE OVERHEAD DOOR1 | BULK STORAGE OVERHEAD DOOR2 | BULK STORAGE OVERHEAD DOOR3 | BULK STORAGE OVERHEAD DOOR4 | BULK STORAGE OVERHEAD DOOR5 | BULK STORAGE OVERHEAD DOOR6 | BULK STORAGE OVERHEAD DOOR7 | BULK STORAGE DOOR5 | |
BULK STORAGE ROOF | SKYLIGHT_R8C1 | SKYLIGHT_R8C2 | SKYLIGHT_R8C4 | SKYLIGHT_R1C2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C4 | SKYLIGHT_R1C3 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R3C4 | SKYLIGHT_R3C2 | SKYLIGHT_R3C3 | SKYLIGHT_R3C1 | SKYLIGHT_R4C4 | SKYLIGHT_R4C3 | SKYLIGHT_R4C2 | SKYLIGHT_R4C1 | SKYLIGHT_R5C4 | SKYLIGHT_R5C1 | SKYLIGHT_R5C3 | SKYLIGHT_R5C2 | SKYLIGHT_R6C1 | SKYLIGHT_R6C2 | SKYLIGHT_R8C3 | SKYLIGHT_R6C4 | SKYLIGHT_R7C1 | SKYLIGHT_R7C2 | SKYLIGHT_R7C4 | SKYLIGHT_R6C3 | SKYLIGHT_R7C3 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
VersionVersion ID | |
1 | 22.1 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 9.70 | 6.00 | -2.20 | -3.40 | -4.20 | 2.70 | 7.50 | 13.70 | 18.60 | 22.00 | 20.70 | 16.50 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Buffalo Niagara Intl AP NY USA TMY3 WMO#=725280 | 42.93 | -78.73 | -5.00 | 215.00 | 98769 | 1.1739 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 8.97 | 26.20 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | Warehouse | 90.000 | Urban | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.220 | 370.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 3 | 102 | 78 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | ZONE1 OFFICE | 0.0 | 0.00 | 0.00 | 0.00 | 4.57 | -12.95 | 2.13 | 1 | 1 | 1 | 0.00 | 9.14 | -25.91 | 5.60E-016 | 0.00 | 4.27 | 4.27 | 1010.76 | TARP | TARP | 236.88 | 149.56 | 128.00 | 17.66 | 6 | 6 | 0 | Yes |
2 | ZONE2 FINE STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 14.29 | -22.82 | 4.51 | 1 | 1 | 1 | 0.00 | 30.48 | -45.72 | 1.87E-015 | 0.00 | 8.53 | 7.81 | 2953.02 | TARP | TARP | 1393.41 | 760.80 | 727.17 | 20.81 | 11 | 20 | 0 | Yes |
3 | ZONE3 BULK STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 65.53 | -22.86 | 4.27 | 1 | 1 | 1 | 30.48 | 100.58 | -45.72 | 6.16E-015 | 0.00 | 8.53 | 8.53 | 35277.63 | TARP | TARP | 3204.84 | 1586.63 | 1471.35 | 47.57 | 6 | 52 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | ZONE1 OFFICE | 236.88 | 12.7 | 18.581 | 5.382E-002 | 6.086 | 8.074 | 0.000 | 0.000 | 0.000 | 0.000 | 14.160 | No |
2 | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 46.447 | 2.153E-002 | 6.684 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.684 | No |
3 | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 46.447 | 2.153E-002 | 3.197 | 2.559 | 0.000 | 0.000 | 0.000 | 0.000 | 5.756 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
1 | OFFICE PEOPLE | BLDG_OCC_SCH | ZONE1 OFFICE | 236.88 | 12.7 | 12.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | OFFICE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 13 |
2 | ZONE2 FINE STORAGEPEOPLE | BLDG_OCC_SCH | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 30.0 | 2.153E-002 | 46.447 | 0.300 | 0.700 | AutoCalculate | ZONE2 FINE STORAGE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 30 |
3 | ZONE3 BULK STORAGEPEOPLE | BLDG_OCC_SCH | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 69.0 | 2.153E-002 | 46.447 | 0.300 | 0.700 | AutoCalculate | ZONE3 BULK STORAGE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 69 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | OFFICE LIGHTS | LTG_SCH_OFFICE | ZONE1 OFFICE | 236.88 | 12.7 | 1441.602 | 6.086 | 113.078 | 0.000 | 0.370 | 0.180 | 0.450 | 1.000 | LightsWired | 0.000 | 1441.602 |
2 | FINE STORAGE AREA LIGHTS | LTG_SCH_FINE_STORAGE | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 9314.081 | 6.684 | 310.469 | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 9314.081 |
3 | BULK STORAGE AREA LIGHTS | LTG_SCH_BULK_STORAGE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 10245.499 | 3.197 | 148.485 | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 10245.499 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | OFFICE PLUG LOAD | OFFICE_PLUG_SCH | ZONE1 OFFICE | 236.88 | 12.7 | 1912.500 | 8.074 | 150.015 | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 1912.500 |
2 | BULK STORAGE PLUG LOAD | BULK STORAGE PLUG SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 8200.120 | 2.559 | 118.842 | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 8200.120 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | NONRES_ROOF | 16 | 2 | 2 | 0.167 | 0.2043 | 0.900 | 0.900 | 0.770 | 0.700 | Smooth |
2 | SEMIHEATED_ROOF | 18 | 2 | 2 | 0.167 | 0.2043 | 0.900 | 0.900 | 0.770 | 0.700 | Smooth |
3 | NONRES_EXT_WALL_GRD | 19 | 3 | 4 | 0.167 | 0.3969 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | SEMIHEATED_EXT_WALL_GRD | 25 | 3 | 4 | 0.167 | 0.3969 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | SWINGING DOOR_CON | 41 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
6 | SWINGING DOOR_SEMI | 42 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | OVERHEAD DOOR_SEMI | 44 | 1 | 1 | 0.167 | 1.760 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
8 | OVERHEAD DOOR_CON | 45 | 1 | 1 | 0.167 | 1.760 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
9 | BULK STORAGE PRODUCTS | 46 | 1 | 18 | 0.500 | 0.5914 | 0.900 | 0.900 | 0.700 | 0.700 | Rough |
10 | INTERIOR WALL | 47 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
11 | INSULATEDCEILING | 48 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
12 | OFFICEFLOOR_FFACTOR | 49 | 2 | 7 | 0.167 | 0.1360 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | FINESTORAGEFLOOR_FFACTOR | 50 | 2 | 7 | 0.167 | 0.5623E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | BULKSTORAGEFLOOR_FFACTOR | 51 | 2 | 7 | 0.167 | 0.5264E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | iz-INTERIOR WALL | 52 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
16 | iz-SEMIHEATED_EXT_WALL_GRD | 53 | 3 | 4 | 0.167 | 0.3969 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
17 | iz-INSULATEDCEILING | 54 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
2 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.894 |
3 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
4 | SEMIHEATED_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.894 |
5 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
6 | NONRES_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 2.420 |
7 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | SEMIHEATED_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 2.420 |
10 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
11 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
12 | OPAQUE DOOR PANEL_SEMI | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
13 | OVERHEAD DOOR_SEMI PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.5681 |
14 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.5681 |
15 | BULK STORAGE PRODUCTS MATERIAL | 2.4384 | 1.442 | 200.231 | 836.800 | 1.691 |
16 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
17 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
18 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
19 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
20 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
21 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
22 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
23 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 7.276 |
24 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
25 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 17.71 |
26 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
27 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 18.92 |
28 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
29 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
30 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
31 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
32 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
33 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
34 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
35 | SEMIHEATED_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 2.420 |
36 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
37 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
38 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 2 | 0.93400083E-12 | 0.71827744E-17 | 0.33026303E-17 | 0.0000000 |
2 | 1 | -5.2160660 | 0.53236032E-04 | -0.78408200E-04 | 0.17906231E-12 |
3 | 0 | 5.4203831 | 0.20426382 | 0.20439547 | |
4 | 2 | 0.93400083E-12 | 0.71827744E-17 | 0.33026303E-17 | 0.0000000 |
5 | 1 | -5.2160660 | 0.53236032E-04 | -0.78408200E-04 | 0.17906231E-12 |
6 | 0 | 5.4203831 | 0.20426382 | 0.20439547 | |
7 | 4 | 0.79902452E-12 | 0.91741022E-16 | -0.20424744E-14 | 0.11342756E-15 |
8 | 3 | -0.39057407E-03 | 0.28070621E-06 | -0.56712558E-04 | 0.15331003E-12 |
9 | 2 | 1.7533726 | 0.60989376E-02 | 1.1509734 | -0.74879759E-04 |
10 | 1 | -7.1105134 | 0.15738863 | -17.165248 | 0.33605900 |
11 | 0 | 5.6211023 | 0.10008308 | 16.277902 | |
12 | 4 | 0.79902452E-12 | 0.91741022E-16 | -0.20424744E-14 | 0.11342756E-15 |
13 | 3 | -0.39057407E-03 | 0.28070621E-06 | -0.56712558E-04 | 0.15331003E-12 |
14 | 2 | 1.7533726 | 0.60989376E-02 | 1.1509734 | -0.74879759E-04 |
15 | 1 | -7.1105134 | 0.15738863 | -17.165248 | 0.33605900 |
16 | 0 | 5.6211023 | 0.10008308 | 16.277902 | |
17 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
18 | 0 | 2.1009573 | 2.1009573 | 2.1009573 | |
19 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
20 | 0 | 2.1009573 | 2.1009573 | 2.1009573 | |
21 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
22 | 0 | 1.7602615 | 1.7602615 | 1.7602615 | |
23 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
24 | 0 | 1.7602615 | 1.7602615 | 1.7602615 | |
25 | 18 | 0.12003549E-12 | -0.36149852E-21 | 0.11999160E-12 | -0.69171859E-14 |
26 | 17 | -0.26702818E-10 | 0.22043783E-17 | -0.26702965E-10 | 0.15647703E-11 |
27 | 16 | 0.26199194E-08 | 0.46087291E-16 | 0.26199192E-08 | -0.15597178E-09 |
28 | 15 | -0.14918350E-06 | -0.27301975E-15 | -0.14918350E-06 | 0.90448703E-08 |
29 | 14 | 0.54929883E-05 | 0.10218664E-13 | 0.54929883E-05 | -0.34010628E-06 |
30 | 13 | -0.13812653E-03 | 0.13886261E-11 | -0.13812653E-03 | 0.87613853E-05 |
31 | 12 | 0.24466257E-02 | 0.76740851E-10 | 0.24466257E-02 | -0.15954016E-03 |
32 | 11 | -0.31099262E-01 | 0.20215154E-08 | -0.31099262E-01 | 0.20926433E-02 |
33 | 10 | 0.28694928 | 0.26940884E-07 | 0.28694928 | -0.20002833E-01 |
34 | 9 | -1.9353699 | 0.18750649E-06 | -1.9353699 | 0.14030665 |
35 | 8 | 9.5767226 | 0.68900696E-06 | 9.5767226 | -0.72468789 |
36 | 7 | -34.784653 | 0.13258951E-05 | -34.784653 | 2.7565275 |
37 | 6 | 92.438040 | 0.12976568E-05 | 92.438040 | -7.6923258 |
38 | 5 | -178.18614 | 0.60985027E-06 | -178.18614 | 15.604270 |
39 | 4 | 245.02895 | 0.12430126E-06 | 245.02895 | -22.615757 |
40 | 3 | -233.27712 | 0.91617964E-08 | -233.27712 | 22.714127 |
41 | 2 | 145.61910 | 0.16319500E-09 | 145.61910 | -14.964058 |
42 | 1 | -53.478849 | 0.26256209E-11 | -53.478849 | 5.7996512 |
43 | 0 | 8.7411694 | -0.39181092E-12 | 8.7411694 | |
44 | 5 | -0.68112304E-12 | 0.61645773E-13 | -0.20199983E-12 | 0.95058421E-15 |
45 | 4 | 0.71499529E-06 | 0.73238302E-07 | 0.28552134E-06 | -0.33479849E-12 |
46 | 3 | -0.58529659E-02 | 0.62218017E-03 | -0.21917430E-02 | 0.29169470E-06 |
47 | 2 | 1.2914758 | 0.88958368E-01 | 0.40042664 | -0.15953103E-02 |
48 | 1 | -8.6129398 | 0.38073474 | -3.1694576 | 0.22491773 |
49 | 0 | 7.9317533 | 0.13060792 | 3.3724149 | |
50 | 3 | -0.49407978E-15 | 0.44230608E-16 | -0.53860842E-16 | 0.0000000 |
51 | 2 | 0.54884850E-03 | 0.14309697E-03 | 0.26444340E-03 | -0.39739853E-15 |
52 | 1 | -3.9407614 | 2.0053241 | -3.6132068 | 0.31450573E-03 |
53 | 0 | 13.994357 | 8.0573072 | 13.672611 | |
54 | 7 | -0.31240856E-08 | -0.21887765E-14 | 0.14182747E-14 | -0.45258500E-16 |
55 | 6 | 0.39303604E-05 | 0.26006625E-08 | 0.31948254E-02 | -0.26800873E-04 |
56 | 5 | -0.27546567E-03 | 0.15375372E-05 | -0.22400621 | 0.19586362E-02 |
57 | 4 | 0.62896480E-02 | 0.69930755E-04 | 4.8342361 | -0.45310069E-01 |
58 | 3 | -0.55086064E-01 | 0.55565958E-03 | -38.047911 | 0.39894661 |
59 | 2 | 0.19539610 | 0.92379386E-03 | 116.53551 | -1.4186290 |
60 | 1 | -0.28189481 | 0.28115072E-03 | -143.93766 | 2.0495388 |
61 | 0 | 0.13740557 | 0.68297879E-05 | 60.838472 | |
62 | 7 | -0.76172223E-08 | 0.19992769E-15 | -0.36679418E-14 | 0.15936503E-16 |
63 | 6 | 0.20832875E-05 | 0.10921259E-08 | 0.32010154E-02 | -0.26852800E-04 |
64 | 5 | -0.12434769E-03 | 0.63986796E-06 | -0.22435781 | 0.19617397E-02 |
65 | 4 | 0.26900562E-02 | 0.28962460E-04 | 4.8400881 | -0.45366326E-01 |
66 | 3 | -0.23075003E-01 | 0.22921474E-03 | -38.080948 | 0.39931181 |
67 | 2 | 0.81154666E-01 | 0.37960809E-03 | 116.59978 | -1.4194888 |
68 | 1 | -0.11662584 | 0.11498440E-03 | -143.97548 | 2.0501605 |
69 | 0 | 0.56734574E-01 | 0.27738523E-05 | 60.838472 | |
70 | 7 | -0.81392023E-08 | 0.28718252E-15 | -0.25842544E-14 | 0.71742475E-17 |
71 | 6 | 0.20245979E-05 | 0.10259199E-08 | 0.32012942E-02 | -0.26855138E-04 |
72 | 5 | -0.11816234E-03 | 0.60006224E-06 | -0.22437362 | 0.19618793E-02 |
73 | 4 | 0.25345016E-02 | 0.27140048E-04 | 4.8403509 | -0.45368853E-01 |
74 | 3 | -0.21665828E-01 | 0.21464768E-03 | -38.082430 | 0.39932820 |
75 | 2 | 0.76088909E-01 | 0.35527252E-03 | 116.60266 | -1.4195273 |
76 | 1 | -0.10927342 | 0.10751462E-03 | -143.97718 | 2.0501884 |
77 | 0 | 0.53139756E-01 | 0.25964760E-05 | 60.838472 | |
78 | 5 | -0.20199983E-12 | 0.61645773E-13 | -0.68112304E-12 | 0.95058421E-15 |
79 | 4 | 0.28552134E-06 | 0.73238302E-07 | 0.71499529E-06 | -0.33479849E-12 |
80 | 3 | -0.21917430E-02 | 0.62218017E-03 | -0.58529659E-02 | 0.29169470E-06 |
81 | 2 | 0.40042664 | 0.88958368E-01 | 1.2914758 | -0.15953103E-02 |
82 | 1 | -3.1694576 | 0.38073474 | -8.6129398 | 0.22491773 |
83 | 0 | 3.3724149 | 0.13060792 | 7.9317533 | |
84 | 4 | -0.20424744E-14 | 0.91741022E-16 | 0.79902452E-12 | 0.11342756E-15 |
85 | 3 | -0.56712558E-04 | 0.28070621E-06 | -0.39057407E-03 | 0.15331003E-12 |
86 | 2 | 1.1509734 | 0.60989376E-02 | 1.7533726 | -0.74879759E-04 |
87 | 1 | -17.165248 | 0.15738863 | -7.1105134 | 0.33605900 |
88 | 0 | 16.277902 | 0.10008308 | 5.6211023 | |
89 | 3 | -0.53860842E-16 | 0.44230608E-16 | -0.49407978E-15 | 0.0000000 |
90 | 2 | 0.26444340E-03 | 0.14309697E-03 | 0.54884850E-03 | -0.39739853E-15 |
91 | 1 | -3.6132068 | 2.0053241 | -3.9407614 | 0.31450573E-03 |
92 | 0 | 13.672611 | 8.0573072 | 13.994357 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | Conductance (Before Adjusted) {W/m2-K} | Convection Coefficient Adjustment Ratio | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.3624_SHGC_SOUTH_0.38 | 34 | 1 | VerySmooth | 2.059 | 2.059 | 1.000 | 0.381 | ||
2 | NONRESWINDOW_U_0.3624_SHGC_NORTH_0.38 | 35 | 1 | VerySmooth | 2.059 | 2.059 | 1.000 | 0.381 | ||
3 | NONRESWINDOW_U_0.3624_SHGC_EAST_0.38 | 36 | 1 | VerySmooth | 2.059 | 2.059 | 1.000 | 0.381 | ||
4 | NONRESWINDOW_U_0.3624_SHGC_WEST_0.38 | 37 | 1 | VerySmooth | 2.059 | 2.059 | 1.000 | 0.381 | ||
5 | SKYLIGHT_U_0.75_SHGC_0.6 | 38 | 1 | VerySmooth | 4.262 | 4.262 | 1.000 | 0.605 | ||
6 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | 39 | 1 | VerySmooth | 4.262 | 4.262 | 1.000 | 0.605 | ||
7 | SKYLIGHT DOUBLE CLEAR | 43 | 3 | VerySmooth | 3.715 | 3.715 | 1.000 | 0.720 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER SOUTH | SpectralAverage | 3.63294E-002 | 0.29373 | 0.50046 | 0.50046 | 0.38000 | 0.13982 | 0.18519 | 0.00000 | 0.84000 | 0.84000 | 0.11606 | 1.00000 | No | |
2 | NONRES WINDOW GLAZING LAYER NORTH | SpectralAverage | 3.63294E-002 | 0.29373 | 0.50046 | 0.50046 | 0.38000 | 0.13982 | 0.18519 | 0.00000 | 0.84000 | 0.84000 | 0.11606 | 1.00000 | No | |
3 | NONRES WINDOW GLAZING LAYER EAST | SpectralAverage | 3.63294E-002 | 0.29373 | 0.50046 | 0.50046 | 0.38000 | 0.13982 | 0.18519 | 0.00000 | 0.84000 | 0.84000 | 0.11606 | 1.00000 | No | |
4 | NONRES WINDOW GLAZING LAYER WEST | SpectralAverage | 3.63294E-002 | 0.29373 | 0.50046 | 0.50046 | 0.38000 | 0.13982 | 0.18519 | 0.00000 | 0.84000 | 0.84000 | 0.11606 | 1.00000 | No | |
5 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.47441 | 0.15233 | 0.15233 | 0.60000 | 0.13030 | 0.15164 | 0.00000 | 0.84000 | 0.84000 | 2.99465E-002 | 1.00000 | No | |
6 | SEMIHEATED SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.47441 | 0.15233 | 0.15233 | 0.60000 | 0.13030 | 0.15164 | 0.00000 | 0.84000 | 0.84000 | 2.99465E-002 | 1.00000 | No | |
7 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No | |
8 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No |
Material Name | GasType | Thickness {m} | |
1 | AIR 3MM | Air | 3.200E-003 |
Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
Enclosure Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Enclosures | |
1 | ZONE1 OFFICE | 4 | 0 |
2 | ZONE2 FINE STORAGE | 14 | 0 |
3 | ZONE3 BULK STORAGE | 32 | 0 |
Enclosure Name | Number of Adjacent Enclosures with Windows | Adjacent Enclosure Names - 1st 100 (max) | |
1 | ZONE1 OFFICE | 0 | |
2 | ZONE2 FINE STORAGE | 0 | |
3 | ZONE3 BULK STORAGE | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 7.5708E-002 | 6154.7 | 1.056 | 0.5354 |
Construction Name | Frame and Divider Name | NFRC Product Type | Assembly U-Factor {W/m2-K} | Assembly SHGC | Assembly Visible Transmittance | |
1 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | CurtainWall | 4.099 | 0.605 | 0.602 |
2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | CurtainWall | 4.099 | 0.605 | 0.602 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | OFFICE INFILTRATION | OFFICE INFIL SCHEDULE | ZONE1 OFFICE | 236.88 | 12.7 | 2.130E-002 | 8.990E-005 | 1.388E-004 | 7.585E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | OFFICE DOOR INFILTRATION | INFIL_DOOR_OPENING_SCH | ZONE1 OFFICE | 236.88 | 12.7 | 0.289 | 1.219E-003 | 1.882E-003 | 1.029 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | FINE STORAGE INFILTRATION | FINE SORAGE INFIL SCHEDULE | ZONE2 FINE STORAGE | 1393.41 | 30.0 | 0.108 | 7.775E-005 | 4.952E-005 | 0.132 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | BULK STORAGE INFILTRATION | BULK STORAGE INFIL_BASE SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 2.032 | 6.340E-004 | 4.141E-004 | 0.207 | 0.000 | 0.000 | 0.224 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
1 | BULK STORAGE VENTILATION-1 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 37.760 | 1.178E-002 | 0.547 | 3.853 | Exhaust | 31.136 | 0.5 | 1.000 | 0.000 | 0.000 | 0.000 | 29.44 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
2 | BULK STORAGE VENTILATION-2 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 69.0 | 0.944 | 2.945E-004 | 1.368E-002 | 9.632E-002 | Natural | 0.000 | 1.0 | 0.000 | 0.000 | 0.224 | 0.000 | -73.33 | 29.44 | -100.00 | -100.00 | 100.00 | 40.00 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | ZONE1 OFFICE | Mixing/Well-Stirred |
2 | ZONE2 FINE STORAGE | Mixing/Well-Stirred |
3 | ZONE3 BULK STORAGE | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Sky Type | MonthAndDay | Daylighting Control Name | Enclosure Name | Window Name | Reference Point | Daylight Factor | |
1 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.4527E-004 |
2 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.9450E-004 |
3 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.2751E-004 |
4 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.2432E-004 |
5 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.2341E-004 |
6 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.1183E-003 |
7 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.5727E-004 |
8 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_1 | ZONE2 FINE STORAGE_DAYLREFPT2 | 7.2026E-004 |
9 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.6650E-004 |
10 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT2 | 4.9349E-004 |
11 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.2193E-004 |
12 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.3998E-004 |
13 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.4401E-004 |
14 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT2 | 4.4765E-004 |
15 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.7631E-004 |
16 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_6 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.3735E-004 |
17 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.6743E-004 |
18 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.5387E-004 |
19 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT1 | 4.7241E-004 |
20 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.7892E-004 |
21 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT1 | 7.0436E-004 |
22 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.9943E-004 |
23 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.2192E-003 |
24 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_7 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.2548E-004 |
25 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.9149E-004 |
26 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.5161E-004 |
27 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT1 | 8.8527E-004 |
28 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.6309E-004 |
29 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.5536E-003 |
30 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.2295E-004 |
31 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.0518E-003 |
32 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_8 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.7651E-005 |
33 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.7190E-004 |
34 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.0993E-004 |
35 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.8254E-004 |
36 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.1529E-004 |
37 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.3043E-003 |
38 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.7568E-005 |
39 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.3050E-004 |
40 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_9 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.9351E-005 |
41 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.6984E-004 |
42 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.2086E-005 |
43 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT1 | 6.1941E-004 |
44 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.4758E-005 |
45 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.4776E-004 |
46 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.8064E-005 |
47 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.9123E-004 |
48 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_10 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.6423E-005 |
49 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.7271E-003 |
50 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.8083E-005 |
51 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.1000E-003 |
52 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.0243E-004 |
53 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.9334E-004 |
54 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.9278E-005 |
55 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.8041E-004 |
56 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_5 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.6567E-005 |
57 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.7991E-003 |
58 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.2713E-004 |
59 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.1633E-003 |
60 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.3736E-004 |
61 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.8476E-003 |
62 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.0126E-004 |
63 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.7108E-003 |
64 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_4 | ZONE2 FINE STORAGE_DAYLREFPT2 | 8.9807E-005 |
65 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.3456E-003 |
66 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.1078E-004 |
67 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.1926E-003 |
68 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.3925E-004 |
69 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.5590E-003 |
70 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.3658E-004 |
71 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.3923E-003 |
72 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_3 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.9389E-005 |
73 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.1645E-004 |
74 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT2 | 5.1117E-004 |
75 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT1 | 7.6072E-004 |
76 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT2 | 6.1136E-004 |
77 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.1658E-003 |
78 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.6393E-004 |
79 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.4880E-003 |
80 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_2 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.3403E-004 |
81 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.3360E-004 |
82 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.5000E-003 |
83 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT1 | 2.7410E-004 |
84 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.8355E-003 |
85 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT1 | 3.1282E-004 |
86 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT2 | 7.8008E-004 |
87 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT1 | 5.2548E-004 |
88 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_14 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.9448E-004 |
89 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.5893E-004 |
90 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.6217E-003 |
91 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.3789E-004 |
92 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT2 | 3.0355E-003 |
93 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.3414E-004 |
94 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.3552E-003 |
95 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.7670E-004 |
96 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_13 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.2140E-003 |
97 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0606E-004 |
98 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.6372E-003 |
99 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.7916E-005 |
100 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT2 | 2.5785E-003 |
101 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.5817E-005 |
102 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT2 | 3.8149E-003 |
103 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0952E-004 |
104 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_12 | ZONE2 FINE STORAGE_DAYLREFPT2 | 4.8074E-003 |
105 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0275E-004 |
106 | Clear Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.0446E-003 |
107 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.5422E-005 |
108 | Clear Turbid Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT2 | 9.5629E-004 |
109 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT1 | 9.3645E-005 |
110 | Intermediate Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.6386E-003 |
111 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT1 | 1.0607E-004 |
112 | Overcast Sky | 01/21 | ZONE2 FINE STORAGE_DAYLCTRL | ZONE2 FINE STORAGE | FINESTORAGE_SKYLIGHT_11 | ZONE2 FINE STORAGE_DAYLREFPT2 | 1.9054E-003 |
113 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.5361E-005 |
114 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.1892E-005 |
115 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.8133E-005 |
116 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.7795E-005 |
117 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.5789E-005 |
118 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.1875E-005 |
119 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.6204E-005 |
120 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.6978E-005 |
121 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.7914E-005 |
122 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.4849E-005 |
123 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.4762E-005 |
124 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.5513E-005 |
125 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.8752E-005 |
126 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.3988E-005 |
127 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.1603E-005 |
128 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.7987E-005 |
129 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.4065E-005 |
130 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.3686E-005 |
131 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.7547E-005 |
132 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.2135E-005 |
133 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.7691E-005 |
134 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.4188E-005 |
135 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.6179E-005 |
136 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.6280E-005 |
137 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.8531E-004 |
138 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.3665E-004 |
139 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.2694E-004 |
140 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.7102E-004 |
141 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.9451E-004 |
142 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.5648E-004 |
143 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.2840E-005 |
144 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.8788E-005 |
145 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0676E-004 |
146 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.8047E-004 |
147 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1004E-004 |
148 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.8017E-004 |
149 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0012E-004 |
150 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.4189E-004 |
151 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.6674E-005 |
152 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.8401E-005 |
153 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4285E-004 |
154 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.1984E-005 |
155 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5597E-004 |
156 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.2024E-005 |
157 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1170E-004 |
158 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.1660E-005 |
159 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.6649E-005 |
160 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.6333E-005 |
161 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 4.4340E-004 |
162 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.8320E-005 |
163 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.3452E-004 |
164 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.2048E-005 |
165 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2318E-004 |
166 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.8379E-005 |
167 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.2818E-005 |
168 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R1C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.6078E-005 |
169 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5345E-004 |
170 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.2354E-003 |
171 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5367E-004 |
172 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.5011E-003 |
173 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.6587E-004 |
174 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.1021E-004 |
175 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0481E-004 |
176 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.5886E-004 |
177 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.1129E-004 |
178 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.0560E-004 |
179 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 6.9567E-004 |
180 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.5605E-004 |
181 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.0248E-004 |
182 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.2973E-004 |
183 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2532E-004 |
184 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.5335E-004 |
185 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.5918E-004 |
186 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0930E-004 |
187 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1509E-003 |
188 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1099E-004 |
189 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 5.9093E-004 |
190 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0775E-004 |
191 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2519E-004 |
192 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.1885E-005 |
193 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.0611E-004 |
194 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.5350E-005 |
195 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.1932E-004 |
196 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.4615E-005 |
197 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.9040E-004 |
198 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.6622E-005 |
199 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0473E-004 |
200 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R2C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9439E-005 |
201 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5600E-003 |
202 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.2545E-004 |
203 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7700E-003 |
204 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.2196E-004 |
205 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5140E-003 |
206 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.4238E-004 |
207 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.8908E-004 |
208 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.8211E-005 |
209 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1398E-003 |
210 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.8757E-004 |
211 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2302E-003 |
212 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.2072E-004 |
213 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3163E-003 |
214 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.7014E-004 |
215 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.8995E-004 |
216 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.7855E-004 |
217 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.6402E-004 |
218 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.7382E-005 |
219 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.6503E-004 |
220 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.5667E-005 |
221 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.1074E-004 |
222 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.0752E-005 |
223 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.8972E-004 |
224 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.3063E-005 |
225 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.0636E-004 |
226 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.2022E-003 |
227 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.9617E-004 |
228 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.5462E-003 |
229 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.6727E-004 |
230 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.0114E-003 |
231 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.9000E-004 |
232 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R3C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0465E-003 |
233 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.6829E-004 |
234 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.7153E-005 |
235 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4904E-004 |
236 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.4650E-005 |
237 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.7838E-004 |
238 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.1690E-005 |
239 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9915E-004 |
240 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.5702E-005 |
241 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.6045E-003 |
242 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.2590E-004 |
243 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5820E-003 |
244 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1674E-004 |
245 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.3225E-003 |
246 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.5698E-004 |
247 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4291E-003 |
248 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.2389E-004 |
249 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3631E-003 |
250 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.0337E-004 |
251 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2948E-003 |
252 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.7131E-004 |
253 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.0697E-003 |
254 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.1064E-004 |
255 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.4336E-003 |
256 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.8360E-004 |
257 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2929E-004 |
258 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.3840E-003 |
259 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.0520E-004 |
260 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.3793E-003 |
261 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.2646E-004 |
262 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.3624E-003 |
263 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9975E-004 |
264 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R4C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.9790E-003 |
265 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.1009E-004 |
266 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.4668E-005 |
267 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.8414E-004 |
268 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.1890E-005 |
269 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9062E-004 |
270 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.8507E-005 |
271 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9750E-004 |
272 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.5670E-005 |
273 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.9827E-004 |
274 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.2299E-003 |
275 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.7001E-004 |
276 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0476E-003 |
277 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.5502E-004 |
278 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.7319E-003 |
279 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.9810E-004 |
280 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.9042E-003 |
281 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.9529E-004 |
282 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0926E-004 |
283 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.6783E-004 |
284 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.8280E-005 |
285 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3298E-003 |
286 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.3317E-004 |
287 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.3923E-003 |
288 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.2355E-004 |
289 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.5787E-004 |
290 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.1416E-004 |
291 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.2456E-004 |
292 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.5817E-004 |
293 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2170E-003 |
294 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.2395E-004 |
295 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.3968E-003 |
296 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R5C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.7651E-004 |
297 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4088E-004 |
298 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.5887E-004 |
299 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.1891E-004 |
300 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.6915E-004 |
301 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4455E-004 |
302 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9612E-004 |
303 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.8771E-004 |
304 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0145E-003 |
305 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.8063E-004 |
306 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.2722E-004 |
307 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.0659E-004 |
308 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.8962E-004 |
309 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 4.0317E-004 |
310 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.6608E-004 |
311 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.6872E-004 |
312 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 3.7148E-004 |
313 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.6886E-005 |
314 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.4046E-005 |
315 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.4262E-005 |
316 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.0039E-005 |
317 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.0111E-005 |
318 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.1295E-005 |
319 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.1582E-005 |
320 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R8C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.5852E-005 |
321 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4013E-004 |
322 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.0892E-005 |
323 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.2037E-004 |
324 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.8329E-005 |
325 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.5995E-004 |
326 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.3028E-005 |
327 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.8744E-004 |
328 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 5.2992E-005 |
329 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.3222E-005 |
330 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.8333E-004 |
331 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.9892E-005 |
332 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.4803E-004 |
333 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.1410E-005 |
334 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.5333E-004 |
335 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0363E-004 |
336 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C1 | ZONE3 BULK STORAGE_DAYLREFPT2 | 2.5247E-004 |
337 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.6673E-004 |
338 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.2231E-004 |
339 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3522E-004 |
340 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.0291E-004 |
341 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3751E-004 |
342 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.1263E-004 |
343 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2024E-004 |
344 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C2 | ZONE3 BULK STORAGE_DAYLREFPT2 | 1.5078E-004 |
345 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 9.1078E-005 |
346 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.6983E-005 |
347 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.9168E-005 |
348 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.4900E-005 |
349 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 8.6851E-005 |
350 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.7851E-005 |
351 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.0355E-004 |
352 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C4 | ZONE3 BULK STORAGE_DAYLREFPT2 | 4.9366E-005 |
353 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.7687E-004 |
354 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 8.6373E-005 |
355 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 3.0675E-004 |
356 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.7150E-005 |
357 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 4.2902E-004 |
358 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.3887E-005 |
359 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 7.6788E-004 |
360 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R6C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 9.7598E-005 |
361 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.6404E-004 |
362 | Clear Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.6982E-005 |
363 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.3405E-004 |
364 | Clear Turbid Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.0582E-005 |
365 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 1.4299E-004 |
366 | Intermediate Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 6.5701E-005 |
367 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT1 | 2.2011E-004 |
368 | Overcast Sky | 01/21 | ZONE3 BULK STORAGE_DAYLCTRL | ZONE3 BULK STORAGE | SKYLIGHT_R7C3 | ZONE3 BULK STORAGE_DAYLREFPT2 | 7.1450E-005 |
369 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 5.1513E-003 |
370 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 6.1856E-004 |
371 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 4.5644E-003 |
372 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 5.5302E-004 |
373 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 4.4358E-003 |
374 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 5.3373E-004 |
375 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT1 | 2.7169E-003 |
376 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW 1 | ZONE1 OFFICE_DAYLREFPT2 | 4.7716E-004 |
377 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 6.3014E-004 |
378 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 5.7879E-003 |
379 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 5.7827E-004 |
380 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 4.8349E-003 |
381 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 5.4506E-004 |
382 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 4.7611E-003 |
383 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 4.7173E-004 |
384 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE FRONT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 3.6541E-003 |
385 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 4.9440E-003 |
386 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 3.5771E-004 |
387 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 3.7254E-003 |
388 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 2.8197E-004 |
389 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 2.5454E-003 |
390 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 2.1230E-004 |
391 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT1 | 3.4076E-003 |
392 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW1 | ZONE1 OFFICE_DAYLREFPT2 | 2.9067E-004 |
393 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 5.1530E-003 |
394 | Clear Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 3.5847E-004 |
395 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 3.8262E-003 |
396 | Clear Turbid Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 2.8237E-004 |
397 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 2.3296E-003 |
398 | Intermediate Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 2.1187E-004 |
399 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT1 | 3.4076E-003 |
400 | Overcast Sky | 01/21 | ZONE1 OFFICE_DAYLCTRL | ZONE1 OFFICE | OFFICE LEFT WALL WINDOW2 | ZONE1 OFFICE_DAYLREFPT2 | 2.9067E-004 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | ZONE1 OFFICE | Cooling | 9377.08629 | 11252.50354 | 0.79136 | 0.94963 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | 29.24600 | 1.33651E-002 | 236.87965 | 12.74874 | 0.10228 | 0.00000 |
2 | ZONE1 OFFICE | Heating | 9141.16146 | 10969.39375 | 0.26311 | 0.31573 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -16.30000 | 9.24091E-004 | 236.87965 | 12.74874 | 0.10228 | 0.00000 |
3 | ZONE2 FINE STORAGE | Cooling | 25620.57202 | 30744.68642 | 1.68551 | 2.02262 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 30.30000 | 1.33670E-002 | 1393.40969 | 30.00000 | 0.42471 | 0.00000 |
4 | ZONE2 FINE STORAGE | Heating | 25977.79188 | 31173.35025 | 0.63007 | 0.75608 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | -16.30000 | 9.24091E-004 | 1393.40969 | 30.00000 | 0.42471 | 0.00000 |
5 | ZONE3 BULK STORAGE | Cooling | 0.00000 | 0.00000 | 0.00000 | 0.97684 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 30.30000 | 1.33670E-002 | 3204.84228 | 69.00000 | 0.97684 | 0.00000 |
6 | ZONE3 BULK STORAGE | Heating | 110450.22915 | 132540.27498 | 2.76796 | 3.32155 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | -16.30000 | 9.24091E-004 | 3204.84228 | 69.00000 | 0.97684 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-OFFICE | Cooling | Sensible | 13981.89 | 0.94963 | 0.94963 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
2 | PSZ-OFFICE | Heating | Sensible | 11564.13 | 0.31573 | 0.31573 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 |
3 | PSZ-FINE STORAGE | Cooling | Sensible | 36873.29 | 2.02262 | 2.02262 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
4 | PSZ-FINE STORAGE | Heating | Sensible | 37760.89 | 0.75608 | 0.75608 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ZONE1 OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.94963 |
2 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ZONE2 FINE STORAGE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 2.02262 |
3 | ZoneHVAC:UnitHeater | ZONE3 BULK STORAGE UNIT HEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 3.32155 |
4 | Fan:ConstantVolume | ZONE3UNITHEATER ZONE3HIRADIANT FAN | Design Size Maximum Flow Rate [m3/s] | 3.32155 |
5 | Coil:Heating:Fuel | ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | Design Size Nominal Capacity [W] | 132540.26673 |
6 | ZoneHVAC:HighTemperatureRadiant | ZONE3 BULK STORAGE HIRADIANT | User-Specified Heating Design Capacity [W] | 132540.27498 |
7 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.94963 |
8 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.94963 |
9 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.94963 |
10 | AirLoopHVAC | PSZ-OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.94963 |
11 | AirLoopHVAC | PSZ-OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.94963 |
12 | AirLoopHVAC | PSZ-OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 0.94963 |
13 | AirLoopHVAC | PSZ-OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
14 | AirLoopHVAC | PSZ-OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.02262 |
16 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.02262 |
17 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.02262 |
18 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Heating Design Air Flow Rate [m3/s] | 2.02262 |
19 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.02262 |
20 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Main Design Air Flow Rate [m3/s] | 2.02262 |
21 | AirLoopHVAC | PSZ-FINE STORAGE | User Heating Air Flow Ratio [] | 1.00000 |
22 | AirLoopHVAC | PSZ-FINE STORAGE | Calculated Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-OFFICE | Design Supply Air Flow Rate [m3/s] | 0.94963 |
24 | AirLoopHVAC | PSZ-FINE STORAGE | Design Supply Air Flow Rate [m3/s] | 2.02262 |
25 | Controller:OutdoorAir | PSZ-OFFICE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.94963 |
26 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.94963 |
27 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 1051.39653 |
28 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.94963 |
29 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.94963 |
30 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.94963 |
31 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.94963 |
32 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.94963 |
33 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.47482 |
34 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.63309 |
35 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 17377.41000 |
36 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 8688.70500 |
37 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.80059 |
38 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.80059 |
39 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 17377.41000 |
40 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 25733.52693 |
41 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
42 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
43 | Coil:Heating:Fuel | PSZ-OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 25733.52693 |
44 | Controller:OutdoorAir | PSZ-FINE STORAGE_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.02262 |
45 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 2.02262 |
46 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 2164.29366 |
47 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 2.02262 |
48 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 2.02262 |
49 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.02262 |
50 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.33493 |
51 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 2.02262 |
52 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.01131 |
53 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.34841 |
54 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Gross Rated Total Cooling Capacity [W] | 47300.86000 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Gross Rated Total Cooling Capacity [W] | 23650.43000 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Rated Sensible Heat Ratio | 0.72024 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Rated Sensible Heat Ratio | 0.72024 |
58 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 47300.86000 |
59 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 74279.25189 |
60 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
61 | AirLoopHVAC:UnitarySystem | PSZ-FINE STORAGE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
62 | Coil:Heating:Fuel | PSZ-FINE STORAGE HEATING COIL | Design Size Nominal Capacity [W] | 74279.25189 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER User {Btu/W-h} | SEER Standard {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | 16640.3 | 12.42 | 12.14 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | 45729.2 | 11.95 | 11.68 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1Environment:Special Days |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | ZONE1 OFFICE | RunPeriod: RUNPERIOD 1 | 0.1764541085 | 0.1561275053 | Pass | Pass | 0.6897226097 | 4.4952741079 | Pass | Pass |
2 | ZONE2 FINE STORAGE | RunPeriod: RUNPERIOD 1 | 0.3804011914 | 0.3450679402 | Pass | Pass | 0.1592437133 | 0.4846974576 | Pass | Pass |
3 | ZONE3 BULK STORAGE | RunPeriod: RUNPERIOD 1 | 1.6105453047E-005 | 2.6925944752E-005 | Pass | Pass | 3.7976005520E-002 | 3.0811706897E-002 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Heat Emission by ComponentsEnvelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
Heat Emissions [GJ] | 8206.41 | 624.95 | 0.00 | 82.10 | 211.61 | 9125.13 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | -16.30 | 0.00 | -16.30 | Wetbulb [C] | 5.10 | 270.00 |
BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 30.30 | 9.30 | 21.80 | Wetbulb [C] | 5.70 | 240.00 |
Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
Jan | 0.00 | 0 | |||
Feb | 0.00 | 0 | |||
Mar | 0.00 | 0 | |||
Apr | 0.00 | 0 | |||
May | 44.00 | 33 | |||
Jun | 0.00 | 0 | |||
Jul | 0.00 | 0 | |||
Aug | 0.00 | 0 | |||
Sep | 67.00 | 33 | |||
Oct | 0.00 | 0 | |||
Nov | 0.00 | 0 | |||
Dec | 0.00 | 0 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.375 | 0.397 | 110.54 | 97.44 | 270.00 | 90.00 | W |
OFFICE LEFT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.375 | 0.397 | 39.02 | 30.56 | 0.00 | 90.00 | N |
OFFICE FLOOR | OFFICEFLOOR_FFACTOR | 1.00 | 0.133 | 0.136 | 236.88 | 236.88 | 90.00 | 180.00 | |
FINE STORAGE FRONT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.375 | 0.397 | 169.07 | 161.64 | 270.00 | 90.00 | W |
FINE STORAGE RIGHT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.375 | 0.397 | 260.10 | 243.29 | 180.00 | 90.00 | S |
FINE STORAGE LEFT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.375 | 0.397 | 182.07 | 172.69 | 0.00 | 90.00 | N |
FINE STORAGE OFFICE FRONT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.375 | 0.397 | 110.54 | 110.54 | 270.00 | 90.00 | W |
FINE STORAGE OFFICE LEFT WALL | NONRES_EXT_WALL_GRD | 0.30 | 0.375 | 0.397 | 39.02 | 39.02 | 0.00 | 90.00 | N |
FINE STORAGE FLOOR | FINESTORAGEFLOOR_FFACTOR | 1.00 | 0.056 | 0.056 | 1156.53 | 1156.53 | 90.00 | 180.00 | |
FINE STORAGE ROOF | NONRES_ROOF | 0.23 | 0.199 | 0.204 | 1393.41 | 1372.60 | 90.00 | 0.00 | |
BULK STORAGE RIGHT WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.375 | 0.397 | 598.24 | 568.60 | 180.00 | 90.00 | S |
BULK STORAGE REAR WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.375 | 0.397 | 390.15 | 358.48 | 90.00 | 90.00 | E |
BULK STORAGE LEFT WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.375 | 0.397 | 598.24 | 544.27 | 0.00 | 90.00 | N |
BULK STORAGE FLOOR | BULKSTORAGEFLOOR_FFACTOR | 1.00 | 0.052 | 0.053 | 3204.84 | 3204.84 | 90.00 | 180.00 | |
BULK STORAGE ROOF | SEMIHEATED_ROOF | 0.23 | 0.199 | 0.204 | 3204.84 | 3157.28 | 270.00 | 0.00 |
Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE RIGHT WALL | INTERIOR WALL | 0.30 | 0.653 | 0.775 | 39.02 | 39.02 | 180.00 | 90.00 | S |
OFFICE REAR WALL | INTERIOR WALL | 0.30 | 0.653 | 0.775 | 110.54 | 110.54 | 90.00 | 90.00 | E |
OFFICE ROOF | INSULATEDCEILING | 0.30 | 2.711 | 10.063 | 236.88 | 236.88 | 90.00 | 0.00 | |
iz-OFFICE RIGHT WALL | iz-INTERIOR WALL | 0.30 | 0.653 | 0.775 | 39.02 | 39.02 | 0.00 | 90.00 | N |
iz-OFFICE REAR WALL | iz-INTERIOR WALL | 0.30 | 0.653 | 0.775 | 110.54 | 110.54 | 270.00 | 90.00 | W |
iz-BULK STORAGE FRONT WALL | iz-SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.362 | 0.397 | 390.15 | 390.15 | 270.00 | 90.00 | W |
iz-OFFICE ROOF | iz-INSULATEDCEILING | 0.30 | 2.711 | 10.063 | 236.88 | 236.88 | 270.00 | 180.00 | |
BULK STORAGE FRONT WALL | SEMIHEATED_EXT_WALL_GRD | 0.30 | 0.362 | 0.397 | 390.15 | 390.15 | 90.00 | 90.00 | E |
BULK STORAGE PRODUCTS SURFACE | BULK STORAGE PRODUCTS | 0.30 | 0.591 | 6028.45 | 0.00 | 90.00 | N |
Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL WINDOW 1 | NONRESWINDOW_U_0.3624_SHGC_WEST_0.38 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 2.059 | 0.381 | 0.381 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | |||||||
OFFICE FRONT WALL WINDOW2 | NONRESWINDOW_U_0.3624_SHGC_WEST_0.38 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 2.059 | 0.381 | 0.381 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | |||||||
OFFICE LEFT WALL WINDOW1 | NONRESWINDOW_U_0.3624_SHGC_NORTH_0.38 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 2.059 | 0.381 | 0.381 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | |||||||
OFFICE LEFT WALL WINDOW2 | NONRESWINDOW_U_0.3624_SHGC_NORTH_0.38 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 2.059 | 0.381 | 0.381 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | |||||||
FINESTORAGE_SKYLIGHT_1 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_6 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_7 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_8 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_9 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_10 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_5 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_4 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_3 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_2 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_14 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_13 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_12 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
FINESTORAGE_SKYLIGHT_11 | SKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_NONRES | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | FINE STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R8C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R8C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R8C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R1C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R1C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R1C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R1C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R2C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R2C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R2C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R2C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R3C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R3C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R3C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R3C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R4C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R4C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R4C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R4C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R5C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R5C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R5C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R5C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R6C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R6C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R8C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R6C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R7C1 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R7C2 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R7C4 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R6C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
SKYLIGHT_R7C3 | SEMIHTDSKYLIGHT_U_0.75_SHGC_0.6 | SKYLIGHT_FRAME_SEMIHEATED | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.605 | 0.602 | 0.000 | 0.000 | CurtainWall | 4.099 | 0.605 | 0.602 | No | BULK STORAGE ROOF | 180.00 | 0.00 | |
Total or Average | 86.04 | 3.810 | 0.559 | 0.557 | |||||||||||||||||
North Total or Average | 6.51 | 2.059 | 0.381 | 0.381 | |||||||||||||||||
Non-North Total or Average | 79.53 | 3.953 | 0.573 | 0.571 |
Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
None |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
OFFICE FRONT DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | OFFICE FRONT WALL |
OFFICE LEFT WALL DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | OFFICE LEFT WALL |
FINE STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_CON | 1.393 | 1.760 | 7.43 | FINE STORAGE FRONT WALL |
FINE STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_CON | 1.393 | 1.760 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_CON | 1.393 | 1.760 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE RIGHT DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_CON | 1.393 | 1.760 | 7.43 | FINE STORAGE LEFT WALL |
FINE STORAGE LEFT DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | FINE STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR8 | OVERHEAD DOOR_SEMI | 1.393 | 1.760 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR9 | OVERHEAD DOOR_SEMI | 1.393 | 1.760 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR10 | OVERHEAD DOOR_SEMI | 1.393 | 1.760 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR11 | OVERHEAD DOOR_SEMI | 1.393 | 1.760 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR1 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR2 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR3 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR12 | OVERHEAD DOOR_SEMI | 1.393 | 1.760 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR13 | OVERHEAD DOOR_SEMI | 1.393 | 1.760 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR14 | OVERHEAD DOOR_SEMI | 1.393 | 1.760 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR15 | OVERHEAD DOOR_SEMI | 1.393 | 1.760 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE DOOR4 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_SEMI | 1.393 | 1.760 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_SEMI | 1.393 | 1.760 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_SEMI | 1.393 | 1.760 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_SEMI | 1.393 | 1.760 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR5 | OVERHEAD DOOR_SEMI | 1.393 | 1.760 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR6 | OVERHEAD DOOR_SEMI | 1.393 | 1.760 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR7 | OVERHEAD DOOR_SEMI | 1.393 | 1.760 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE DOOR5 | SWINGING DOOR_SEMI | 1.598 | 2.101 | 1.95 | BULK STORAGE LEFT WALL |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
OFFICE FRONT WALL WINDOW 1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE FRONT WALL WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE LEFT WALL WINDOW1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
OFFICE LEFT WALL WINDOW2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FINESTORAGE_SKYLIGHT_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_6 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_7 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_8 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_9 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_10 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_5 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_14 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_13 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FINESTORAGE_SKYLIGHT_11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R8C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R8C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R8C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R3C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R3C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R3C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R3C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R4C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R4C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R4C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R4C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R5C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R5C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R5C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R5C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R6C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R6C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R8C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R6C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R7C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R7C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R7C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R6C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R7C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Interior LightingZone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
OFFICE LIGHTS | ZONE1 OFFICE | ZONE1 OFFICE | GENERAL | 6.0858 | 236.88 | 1441.60 | LightsWired | LTG_SCH_OFFICE | 47.92 | 168.00 | 38.96 | 0.0000 | Y | 10.54 |
FINE STORAGE AREA LIGHTS | ZONE2 FINE STORAGE | ZONE2 FINE STORAGE | GENERAL | 6.6844 | 1393.41 | 9314.08 | LightsWired | LTG_SCH_FINE_STORAGE | 34.09 | 168.00 | 23.78 | 0.0000 | Y | 41.57 |
BULK STORAGE AREA LIGHTS | ZONE3 BULK STORAGE | ZONE3 BULK STORAGE | GENERAL | 3.1969 | 3204.84 | 10245.50 | LightsWired | LTG_SCH_BULK_STORAGE | 34.09 | 168.00 | 21.38 | 0.0000 | Y | 41.11 |
Interior Lighting Total | 4.3435 | 4835.13 | 21001.18 | 93.23 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
ZONE2 FINE STORAGE_DAYLREFPT1 | ZONE2 FINE STORAGE | ZONE2 FINE STORAGE_DAYLCTRL | SplitFlux | Continuous/Off | 0.25 | 9314.08 | 2328.52 |
ZONE2 FINE STORAGE_DAYLREFPT2 | ZONE2 FINE STORAGE | ZONE2 FINE STORAGE_DAYLCTRL | SplitFlux | Continuous/Off | 0.25 | 9314.08 | 2328.52 |
ZONE3 BULK STORAGE_DAYLREFPT1 | ZONE3 BULK STORAGE | ZONE3 BULK STORAGE_DAYLCTRL | SplitFlux | Continuous/Off | 0.25 | 10245.50 | 2561.37 |
ZONE3 BULK STORAGE_DAYLREFPT2 | ZONE3 BULK STORAGE | ZONE3 BULK STORAGE_DAYLCTRL | SplitFlux | Continuous/Off | 0.25 | 10245.50 | 2561.37 |
ZONE1 OFFICE_DAYLREFPT1 | ZONE1 OFFICE | ZONE1 OFFICE_DAYLCTRL | SplitFlux | Continuous/Off | 0.29 | 1441.60 | 418.06 |
ZONE1 OFFICE_DAYLREFPT2 | ZONE1 OFFICE | ZONE1 OFFICE_DAYLCTRL | SplitFlux | Continuous/Off | 0.10 | 1441.60 | 144.16 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 93.17 | AstronomicalClock | - | 42.04 | 42.04 | 0.74 | |
EXTERIOR_LIGHTS_B | 4307.58 | AstronomicalClock | - | 83.67 | 62.85 | 50.82 | |
EXTERIOR_LIGHTS_C | 1091.85 | AstronomicalClock | - | 83.67 | 49.42 | 10.13 | |
Exterior Lighting Total | 5492.60 | 61.69 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Central PlantType | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 17377.41 | 13912.18 | 3465.23 | 0.80 | 4.12 | |||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 47300.86 | 34067.97 | 13232.89 | 0.72 | 3.73 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-OFFICE COOLING COIL | 16640.3 | 12.42 | 12.14 | ||||
PSZ-FINE STORAGE COOLING COIL | 45729.2 | 11.95 | 11.68 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | Coil:Heating:Fuel | 132540.27 | 0.81 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | 25733.53 | 0.80 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | 74279.25 | 0.81 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
ZONE3UNITHEATER ZONE3HIRADIANT FAN | Fan:ConstantVolume | 0.54 | 49.80 | 3.32 | 308.61 | 92.91 | 1.00 | 3.31 | General | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 |
PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.56 | 622.50 | 0.95 | 1051.40 | 1107.16 | 1.00 | 1.42 | General | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.58 | 622.50 | 2.02 | 2164.29 | 1070.05 | 1.00 | 1.31 | General | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SWHSYS1 WATER HEATER | WaterHeater:Mixed | 0.08 | 6154.75 | 1.00 | 1.06 | 0.54 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 9377.09 | 11252.50 | 47.50 | 0.791 | 0.950 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | 23.90 | 23.90 | 0.00841 | 29.25 | 0.01337 | 0.102 | 0.00 |
ZONE2 FINE STORAGE | 25620.57 | 30744.69 | 22.06 | 1.686 | 2.023 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 26.70 | 26.70 | 0.00871 | 30.30 | 0.01337 | 0.425 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 | 0.000 | 0.977 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 0.00 | 30.68 | 0.01343 | 30.30 | 0.01337 | 0.977 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 9141.16 | 10969.39 | 46.31 | 0.263 | 0.316 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 21.10 | 21.10 | 0.00795 | -16.30 | 0.00092 | 0.102 | 0.00 |
ZONE2 FINE STORAGE | 25977.79 | 31173.35 | 22.37 | 0.630 | 0.756 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | 15.56 | 15.56 | 0.00698 | -16.30 | 0.00092 | 0.425 | 0.00 |
ZONE3 BULK STORAGE | 110450.23 | 132540.27 | 41.36 | 2.768 | 3.322 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | 10.00 | 10.00 | 0.00478 | -16.30 | 0.00092 | 0.977 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-OFFICE | 0.95 | 0.95 | 0.32 | 0.32 | 0.9496 | 0.9496 | 0.9496 | 1.0000 | 1.0000 |
PSZ-FINE STORAGE | 2.02 | 2.02 | 0.76 | 0.76 | 2.0226 | 2.0226 | 2.0226 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER or ZONEHVAC:HIGHTEMPERATURERADIANT | ZONE3 BULK STORAGE UNIT HEATER or ZONE3 BULK STORAGE HIRADIANT | 132540.267 | 132540.267 | -999.0 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | 132540.27 | 132540.27 | 3.321547 | 10.00 | 6.56 | 0.00477703 | 43.33 | 21.85 | 0.00800000 | -16.30 | 0.00092409 | -16.30 | 0.0000 | 10.00 | 0.00477703 | 61.3200 | 132540.27 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-OFFICE | 17377.410 | 13912.181 | 0.949630 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | 8688.70 | 7516.19 | 0.633087 | 25.41 | 16.99 | 0.00894235 | 12.00 | 11.04 | 0.00800000 | 29.37 | 0.01336531 | 21.56 | 16.1565 | 23.90 | 0.00840813 | 44.4011 | 9371.95 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-OFFICE | 25733.527 | 25733.527 | -999.0 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 25733.53 | 25733.53 | 0.949635 | 17.03 | 12.30 | 0.00718912 | 40.00 | 20.89 | 0.00800000 | -16.30 | 0.00092409 | -16.30 | 10.7709 | 21.10 | 0.00794538 | 49.7732 | 9141.16 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-FINE STORAGE | 47300.860 | 34067.971 | 2.022620 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 23650.43 | 19151.94 | 1.348413 | 28.35 | 18.56 | 0.00969105 | 12.00 | 11.04 | 0.00800000 | 30.30 | 0.01336696 | 21.83 | 31.4971 | 26.70 | 0.00871402 | 38.9391 | 25619.64 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-FINE STORAGE | 74279.252 | 74279.252 | -999.0 | -999.0 | -999.000 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | 74279.25 | 74279.25 | 2.022615 | 8.87 | 7.11 | 0.00570760 | 40.00 | 20.89 | 0.00800000 | -16.30 | 0.00092409 | -16.30 | 20.9981 | 15.56 | 0.00697903 | 62.0011 | 25977.79 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER or ZONEHVAC:HIGHTEMPERATURERADIANT | ZONE3 BULK STORAGE UNIT HEATER or ZONE3 BULK STORAGE HIRADIANT | ZONE3 BULK STORAGE | N/A | N/A | N/A | Yes | No | unknown | No | 132540.267 | 132540.267 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1739 | ZONE3UNITHEATER ZONE3HIRADIANT FAN | Fan:ConstantVolume | 3.321547 | 3.89924799 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | unknown | unknown | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | Sensible | 132540.27 | 132540.27 | 1.0000 | 3.89924799 | 3.321547 | 10.00 | 6.56 | 0.00477703 | 22080.0 | 43.33 | 21.85 | 0.00800000 | 64191.6 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 132540.27 | -16.30 | 0.00092409 | -16.30 | 0.00000000 | 0.0000 | 10.00 | 0.00477703 | 10.00 | 0.00477703 | 61.3200 | 132540.27 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 17377.410 | 13912.181 | 0.949630 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.4634 | 1004.8586 | 1.1739 | PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.949635 | 1.11480040 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:40:00 | Sensible | 8688.70 | 7516.19 | 1.0000 | 0.74319646 | 0.633087 | 25.41 | 16.99 | 0.00894235 | 48321.3 | 12.00 | 11.04 | 0.00800000 | 32244.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8688.70 | 29.37 | 0.01336531 | 21.56 | 0.10228460 | 16.1565 | 23.90 | 0.00840813 | 23.90 | 0.00840813 | 44.4011 | 9371.95 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 25733.527 | 25733.527 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1739 | PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.949635 | 1.11480040 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | unknown | unknown | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | Sensible | 25733.53 | 25733.53 | 1.0000 | 1.11480040 | 0.949635 | 17.03 | 12.30 | 0.00718912 | 35317.6 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25733.53 | -16.30 | 0.00092409 | -16.30 | 0.10228460 | 10.7709 | 21.05 | 0.00794538 | 21.10 | 0.00794538 | 49.7732 | 9141.16 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 47300.860 | 34067.971 | 2.022620 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.8552 | 1004.8586 | 1.1739 | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 2.022615 | 2.37439895 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | Sensible | 23650.43 | 19151.94 | 1.0000 | 1.58293655 | 1.348413 | 28.35 | 18.56 | 0.00969105 | 53230.2 | 12.00 | 11.04 | 0.00800000 | 32244.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 23650.43 | 30.30 | 0.01336696 | 21.83 | 0.42471127 | 31.4971 | 26.70 | 0.00871402 | 26.70 | 0.00871402 | 38.9391 | 25619.64 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 74279.252 | 74279.252 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1739 | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 2.022615 | 2.37439895 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | unknown | unknown | BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | Sensible | 74279.25 | 74279.25 | 1.0000 | 2.37439895 | 2.022615 | 8.87 | 7.11 | 0.00570760 | 23279.2 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 74279.25 | -16.30 | 0.00092409 | -16.30 | 0.42471127 | 20.9981 | 15.56 | 0.00697903 | 15.56 | 0.00697903 | 62.0011 | 25977.79 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-OFFICE_OA_CONTROLLER | DifferentialDryBulb | 0.00 | 0.95 | - | |||
PSZ-FINE STORAGE_OA_CONTROLLER | DifferentialDryBulb | 0.00 | 2.02 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
ZONE1 OFFICE | ZONE1_OFFICE_DCV | 0.002360 | 0.000305 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
ZONE2 FINE STORAGE | ZONE2_FINE_STORAGE_DCV | 0.000000 | 0.000305 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
ZONE1 OFFICE | 2842.33 | 2716.17 | 2119.83 |
ZONE2 FINE STORAGE | 3203.50 | 3119.50 | 2752.33 |
ZONE3 BULK STORAGE | 3237.33 | 3359.33 | 3007.50 |
Facility | 3456.17 | 3422.00 | 3083.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
ZONE1 OFFICE | 32.83 | 0.17 | 19.83 | 0.17 |
ZONE2 FINE STORAGE | 328.67 | 12.67 | 17.33 | 0.00 |
ZONE3 BULK STORAGE | 0.67 | 0.00 | 0.67 | 0.00 |
Facility | 351.67 | 12.83 | 28.50 | 0.17 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 9.47 | 12.75 | 1010.76 | 0.666 | 0.360 | 0.000 | 0.000 |
ZONE2 FINE STORAGE | 22.29 | 30.00 | 2953.02 | 0.508 | 0.082 | 0.000 | 0.000 |
ZONE3 BULK STORAGE | 51.27 | 69.00 | 35277.63 | 0.000 | 0.150 | 0.000 | 0.123 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 9.47 | 12.75 | 1010.76 | 0.000 | 0.000 | 0.000 | 0.000 |
ZONE2 FINE STORAGE | 22.29 | 30.00 | 2953.02 | 0.000 | 0.000 | 0.000 | 0.000 |
ZONE3 BULK STORAGE | 51.27 | 69.00 | 35277.63 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Mechanical Ventilation Parameters by ZoneAirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
ZONE1 OFFICE | PSZ-OFFICE | 9.47 | 12.75 | 1010.76 | 236.88 | 0.1023 | 0.072 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 22.29 | 30.00 | 2953.02 | 1393.41 | 0.4247 | 0.425 |
ZONE3 BULK STORAGE | 51.27 | 69.00 | 35277.63 | 3204.84 | 0.977 | ||
Total Facility | 83.04 | 111.75 | 39241.41 | 4835.13 | 0.5270 | 1.474 |
Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
ZONE1 OFFICE | 2398105.36 | 0.00 | 2398105.36 | 1572787.64 | 3970893.01 | 2577844.23 | 5705.41 | 2230.14 | 824.45 | 0.00 |
ZONE2 FINE STORAGE | 5486463.44 | 0.00 | 5486463.44 | 2241512.65 | 7727976.09 | 13393694.68 | 5695.28 | 2580.60 | 484.12 | 28.62 |
ZONE3 BULK STORAGE | 0.00 | 27811022.29 | 27811022.29 | 38763551.86 | 66574574.15 | 30805497.77 | 7058.48 | 128.25 | 1573.27 | 5048.67 |
Total Facility | 7884568.80 | 27811022.29 | 35695591.10 | 42577852.15 | 78273443.25 | 46777036.68 | 7943.04 | 2838.83 | 2502.66 | 5048.67 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
ZONE1 OFFICE | 0.1832 | 0.0000 | 0.1832 | 0.0998 | 0.2830 | 0.0952 | 581.41 | 2230.14 | 824.45 |
ZONE2 FINE STORAGE | 0.4120 | 0.0000 | 0.4120 | 0.0666 | 0.4786 | 0.4247 | 598.91 | 2580.43 | 456.66 |
ZONE3 BULK STORAGE | 0.0000 | 1.1887 | 1.1887 | 1.4785 | 2.6672 | 0.9768 | 2742.71 | 65.42 | 827.88 |
Total Facility | 0.5952 | 1.1887 | 1.7839 | 1.6449 | 3.4288 | 1.4967 | 2819.04 | 2775.83 | 1733.11 |
Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
PSZ-OFFICE | 3304830.54 | 0.00 | 3304830.54 | 2577844.23 | 5704.02 | 0.08 | 3055.89 | 0.00 |
PSZ-FINE STORAGE | 7560985.61 | 0.00 | 7560985.61 | 13393694.68 | 5693.68 | 0.03 | 3066.28 | 28.62 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
PSZ-OFFICE | 0.2525 | 0.0000 | 0.2525 | 0.0952 | 580.02 | 0.08 | 3055.89 |
PSZ-FINE STORAGE | 0.5678 | 0.0000 | 0.5678 | 0.4247 | 597.51 | 0.00 | 3038.49 |
No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
PSZ-OFFICE | 0.00 | 483.92 | 345.92 | 0.00 | 0.00 | 0.00 | 2229.47 | 0.00 | 0.00 | 0.00 |
PSZ-FINE STORAGE | 0.00 | 377.77 | 133.75 | 0.00 | 0.00 | 0.00 | 2564.20 | 0.00 | 0.00 | 0.00 |
No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
PSZ-OFFICE | 0.0000 | 0.9178 | 0.4991 | 0.0000 | 0.0000 | 0.0000 | 0.1357 | 0.0000 | 0.0000 | 0.0000 |
PSZ-FINE STORAGE | 0.0000 | 1.2902 | 0.8472 | 0.0000 | 0.0000 | 0.0000 | 0.5853 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Surfaces by ClassTotal | Outdoors | |
Wall | 16 | 10 |
Floor | 4 | 3 |
Roof | 3 | 2 |
Internal Mass | 1 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 50 | 50 |
Door | 28 | 28 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 2 |
Conditioned Zones | 3 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 430 |
Defaulted Fields | 389 |
Fields with Defaults | 1172 |
Autosized Fields | 41 |
Autosizable Fields | 97 |
Autocalculated Fields | 128 |
Autocalculatable Fields | 206 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 357.06 | 1606.07 | 12-MAR-14:20 | 30366.73 | 19-JUL-14:50 |
Electricity:Building | 230.15 | 1123.07 | 12-MAR-14:20 | 19432.64 | 27-NOV-16:00 |
Electricity:Zone:ZONE1 OFFICE | 39.71 | 585.18 | 05-MAR-15:00 | 2643.62 | 02-JAN-16:50 |
Electricity:SpaceType:GENERAL | 229.73 | 1123.07 | 12-MAR-14:20 | 19432.64 | 27-NOV-16:00 |
InteriorLights:Electricity | 93.23 | 653.19 | 12-MAR-14:20 | 9397.46 | 27-NOV-16:00 |
InteriorLights:Electricity:Zone:ZONE1 OFFICE | 10.54 | 115.30 | 05-MAR-15:00 | 808.57 | 02-JAN-16:50 |
InteriorLights:Electricity:SpaceType:GENERAL | 93.23 | 653.19 | 12-MAR-14:20 | 9397.46 | 27-NOV-16:00 |
LightsWired:InteriorLights:Electricity | 93.23 | 653.19 | 12-MAR-14:20 | 9397.46 | 27-NOV-16:00 |
LightsWired:InteriorLights:Electricity:Zone:ZONE1 OFFICE | 10.54 | 115.30 | 05-MAR-15:00 | 808.57 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 93.23 | 653.19 | 12-MAR-14:20 | 9397.46 | 27-NOV-16:00 |
Electricity:Zone:ZONE2 FINE STORAGE | 41.57 | 256.14 | 22-JAN-11:30 | 4172.98 | 27-NOV-16:00 |
InteriorLights:Electricity:Zone:ZONE2 FINE STORAGE | 41.57 | 256.14 | 22-JAN-11:30 | 4172.98 | 27-NOV-16:00 |
LightsWired:InteriorLights:Electricity:Zone:ZONE2 FINE STORAGE | 41.57 | 256.14 | 22-JAN-11:30 | 4172.98 | 27-NOV-16:00 |
Electricity:Zone:ZONE3 BULK STORAGE | 148.87 | 281.75 | 01-JAN-10:30 | 12900.30 | 20-JUL-14:40 |
InteriorLights:Electricity:Zone:ZONE3 BULK STORAGE | 41.11 | 281.75 | 01-JAN-10:30 | 4433.29 | 27-NOV-16:00 |
LightsWired:InteriorLights:Electricity:Zone:ZONE3 BULK STORAGE | 41.11 | 281.75 | 01-JAN-10:30 | 4433.29 | 27-NOV-16:00 |
InteriorEquipment:Electricity | 136.51 | 469.88 | 01-JAN-00:10 | 10035.17 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE1 OFFICE | 29.16 | 469.88 | 01-JAN-00:10 | 1835.05 | 02-JAN-08:10 |
InteriorEquipment:Electricity:SpaceType:GENERAL | 136.51 | 469.88 | 01-JAN-00:10 | 10035.17 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity | 136.51 | 469.88 | 01-JAN-00:10 | 10035.17 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ZONE1 OFFICE | 29.16 | 469.88 | 01-JAN-00:10 | 1835.05 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 136.51 | 469.88 | 01-JAN-00:10 | 10035.17 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE3 BULK STORAGE | 107.34 | 0.00 | 01-JAN-00:10 | 8200.12 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ZONE3 BULK STORAGE | 107.34 | 0.00 | 01-JAN-00:10 | 8200.12 | 02-JAN-08:10 |
Fans:Electricity | 29.54 | 0.00 | 11-JAN-18:10 | 4301.52 | 19-JUL-14:30 |
Fans:Electricity:Zone:ZONE3 BULK STORAGE | 0.41 | 0.00 | 01-JAN-00:10 | 2305.29 | 20-JUL-14:40 |
Ventilation (simple):Fans:Electricity | 0.41 | 0.00 | 01-JAN-00:10 | 2305.29 | 20-JUL-14:40 |
Ventilation (simple):Fans:Electricity:Zone:ZONE3 BULK STORAGE | 0.41 | 0.00 | 01-JAN-00:10 | 2305.29 | 20-JUL-14:40 |
ElectricityPurchased:Facility | 357.06 | 1606.07 | 12-MAR-14:20 | 30366.73 | 19-JUL-14:50 |
ElectricityPurchased:Plant | 357.06 | 1606.07 | 12-MAR-14:20 | 30366.73 | 19-JUL-14:50 |
Cogeneration:ElectricityPurchased | 357.06 | 1606.07 | 12-MAR-14:20 | 30366.73 | 19-JUL-14:50 |
General:Cogeneration:ElectricityPurchased | 357.06 | 1606.07 | 12-MAR-14:20 | 30366.73 | 19-JUL-14:50 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 357.06 | 1606.07 | 12-MAR-14:20 | 30366.73 | 19-JUL-14:50 |
ElectricityNet:Plant | 357.06 | 1606.07 | 12-MAR-14:20 | 30366.73 | 19-JUL-14:50 |
Cogeneration:ElectricityNet | 357.06 | 1606.07 | 12-MAR-14:20 | 30366.73 | 19-JUL-14:50 |
General:Cogeneration:ElectricityNet | 357.06 | 1606.07 | 12-MAR-14:20 | 30366.73 | 19-JUL-14:50 |
Electricity:HVAC | 39.14 | 0.00 | 11-JAN-18:10 | 11224.38 | 19-JUL-14:40 |
General:Fans:Electricity | 29.13 | 0.00 | 11-JAN-18:10 | 2843.05 | 07-FEB-08:10 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 10.02 | 0.00 | 01-JAN-00:10 | 9230.63 | 19-JUL-14:40 |
General:Cooling:Electricity | 10.02 | 0.00 | 01-JAN-00:10 | 9230.63 | 19-JUL-14:40 |
ExteriorLights:Electricity | 61.69 | 0.00 | 01-JAN-08:00 | 5492.60 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 61.69 | 0.00 | 01-JAN-08:00 | 5492.60 | 01-JAN-06:10 |
Electricity:Plant | 26.08 | 483.00 | 21-JAN-06:10 | 2690.68 | 16-FEB-12:10 |
WaterSystems:Electricity | 26.08 | 483.00 | 21-JAN-06:10 | 2690.68 | 16-FEB-12:10 |
Water Heater:WaterSystems:Electricity | 26.08 | 483.00 | 21-JAN-06:10 | 2690.68 | 16-FEB-12:10 |
Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
NaturalGas:Facility | 698.24 | 0.00 | 11-JAN-18:10 | 237586.76 | 06-FEB-17:20 |
NaturalGas:HVAC | 698.24 | 0.00 | 11-JAN-18:10 | 237586.76 | 06-FEB-17:20 |
Heating:NaturalGas | 698.24 | 0.00 | 11-JAN-18:10 | 237586.76 | 06-FEB-17:20 |
General:Heating:NaturalGas | 698.24 | 0.00 | 11-JAN-18:10 | 237586.76 | 06-FEB-17:20 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
EnergyTransfer:Facility | 1157.94 | 0.00 | 11-JAN-18:10 | 359523.95 | 06-FEB-17:20 |
EnergyTransfer:Building | 571.36 | 0.00 | 11-JAN-18:10 | 176758.63 | 13-FEB-07:10 |
EnergyTransfer:Zone:ZONE1 OFFICE | 51.70 | 0.00 | 01-JAN-00:10 | 26094.69 | 11-DEC-07:10 |
Heating:EnergyTransfer | 516.63 | 0.00 | 11-JAN-18:10 | 176758.63 | 13-FEB-07:10 |
Heating:EnergyTransfer:Zone:ZONE1 OFFICE | 34.11 | 0.00 | 01-JAN-00:10 | 26094.69 | 11-DEC-07:10 |
General:Heating:EnergyTransfer | 516.63 | 0.00 | 11-JAN-18:10 | 176758.63 | 13-FEB-07:10 |
General:Heating:EnergyTransfer:Zone:ZONE1 OFFICE | 34.11 | 0.00 | 01-JAN-00:10 | 26094.69 | 11-DEC-07:10 |
Cooling:EnergyTransfer | 54.73 | 0.00 | 01-JAN-00:10 | 24096.26 | 21-JUL-13:30 |
Cooling:EnergyTransfer:Zone:ZONE1 OFFICE | 17.59 | 0.00 | 01-JAN-00:10 | 8672.87 | 17-JUL-07:10 |
General:Cooling:EnergyTransfer | 54.73 | 0.00 | 01-JAN-00:10 | 24096.26 | 21-JUL-13:30 |
General:Cooling:EnergyTransfer:Zone:ZONE1 OFFICE | 17.59 | 0.00 | 01-JAN-00:10 | 8672.87 | 17-JUL-07:10 |
EnergyTransfer:Zone:ZONE2 FINE STORAGE | 118.77 | 0.00 | 01-JAN-00:40 | 35828.54 | 06-FEB-22:10 |
Heating:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 81.63 | 0.00 | 01-JAN-00:40 | 35828.54 | 06-FEB-22:10 |
General:Heating:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 81.63 | 0.00 | 01-JAN-00:40 | 35828.54 | 06-FEB-22:10 |
Cooling:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 37.15 | 0.00 | 01-JAN-00:10 | 16827.15 | 21-JUL-13:30 |
General:Cooling:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 37.15 | 0.00 | 01-JAN-00:10 | 16827.15 | 21-JUL-13:30 |
EnergyTransfer:Zone:ZONE3 BULK STORAGE | 400.89 | 0.00 | 06-JAN-10:50 | 133327.57 | 06-FEB-10:00 |
Heating:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 400.89 | 0.00 | 06-JAN-10:50 | 133327.57 | 06-FEB-10:00 |
General:Heating:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 400.89 | 0.00 | 06-JAN-10:50 | 133327.57 | 06-FEB-10:00 |
Cooling:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cooling:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 586.58 | 0.00 | 11-JAN-18:10 | 187563.13 | 06-FEB-17:20 |
HeatingCoils:EnergyTransfer | 541.61 | 0.00 | 11-JAN-18:10 | 187563.13 | 06-FEB-17:20 |
CoolingCoils:EnergyTransfer | 44.97 | 0.00 | 01-JAN-00:10 | 39403.62 | 19-JUL-14:30 |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
ZONE1 OFFICE | 0.000 | 0.000 | 34.110 | -17.587 | 0.000 | 0.000 | 10.082 | 10.544 | 29.165 | 10.043 | 0.000 | 0.332 | 0.000 | 0.000 | -7.979 | 0.000 | -23.781 | -44.928 |
ZONE2 FINE STORAGE | 0.000 | 0.000 | 81.627 | -37.144 | 0.000 | 0.000 | 25.975 | 41.572 | 0.000 | 46.370 | 0.000 | 0.132 | 0.001 | 0.000 | -18.811 | 0.000 | -30.049 | -109.671 |
ZONE3 BULK STORAGE | 400.891 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 65.792 | 41.111 | 107.344 | 447.861 | 0.000 | 9.913 | 0.000 | 0.000 | -148.688 | 0.000 | -553.503 | -370.720 |
Total Facility | 400.891 | 0.000 | 115.738 | -54.731 | 0.000 | 0.000 | 101.849 | 93.226 | 136.508 | 504.274 | 0.000 | 10.377 | 0.001 | 0.000 | -175.478 | 0.000 | -607.332 | -525.320 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 03-JUN-07:02 | 0.00 | 0.00 | 0.00 | -22197.96 | 0.00 | 0.00 | 801.72 | 687.94 | 1835.05 | 7.86 | 0.00 | 0.00 | 19054.76 | 0.00 | -0.00 | 0.00 | -189.37 | 0.00 |
ZONE2 FINE STORAGE | 16-JUL-16:33 | 0.00 | 0.00 | 0.00 | -39578.58 | 0.00 | 0.00 | 0.00 | 292.80 | 0.00 | 4946.07 | 0.00 | 131.05 | 34208.66 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 17-JUL-06:02 | 0.00 | 0.00 | 0.00 | -39930.09 | 0.00 | 0.00 | 1258.53 | 5540.81 | 2967.56 | 11130.50 | 0.00 | 0.00 | 27633.45 | 0.00 | 0.00 | 0.00 | -8600.75 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 11-DEC-07:02 | 0.00 | 0.00 | 27208.78 | 0.00 | 0.00 | 0.00 | 282.67 | 441.04 | 917.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -959.94 | 0.00 | -13169.17 | -14720.91 |
ZONE2 FINE STORAGE | 06-FEB-22:02 | 0.00 | 0.00 | 76240.04 | 0.00 | 0.00 | 0.00 | 0.00 | 512.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2333.77 | 0.00 | -5058.29 | -69360.26 |
ZONE3 BULK STORAGE | 06-FEB-10:00 | 133328.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8357.84 | 2394.89 | 8200.12 | 1866.98 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -142456.62 | -11692.03 |
Total Facility | 06-FEB-00:42 | 129452.97 | 0.00 | 97197.59 | 0.00 | 0.00 | 0.00 | 0.00 | 1264.80 | 2519.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -23290.77 | 0.00 | -109562.79 | -97581.71 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 0.9496 | 0.0000 | 12.7487 | 1.0000 | Calculated from schedules | 0.1023 | 0.9496 | 0.1077 | 1.0000 | Not calculated | 0.1023 | 0.1077 | ||
PSZ-FINE STORAGE | 2.0226 | 0.0000 | 30.0000 | 1.0000 | Calculated from schedules | 0.4247 | 2.0226 | 0.2100 | 1.0000 | Not calculated | 0.4247 | 0.2100 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 0.9496 | 0.0000 | 12.7487 | 1.0000 | Calculated from schedules | 0.1023 | 0.9496 | 1.0000 | 1.0000 | Not calculated | 0.1023 | 0.1077 | ||
PSZ-FINE STORAGE | 2.0226 | 0.0000 | 30.0000 | 1.0000 | Calculated from schedules | 0.4247 | 2.0226 | 1.0000 | 1.0000 | Not calculated | 0.4247 | 0.2100 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
ZONE1 OFFICE | PSZ-OFFICE | 0.002360 | 12.7487 | 0.000305 | 236.88 | 0.1023 | 1.0000 | 0.1023 | 1.000 | 0.1023 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 0.000000 | 30.0000 | 0.000305 | 1393.41 | 0.4247 | 1.0000 | 0.4247 | 1.000 | 0.4247 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-OFFICE | 0.002360 | 12.75 | 0.000305 | 236.8796 | 0.1023 | 0.1023 | 0.1023 |
PSZ-FINE STORAGE | 0.000000 | 30.00 | 0.000305 | 1393.4097 | 0.4247 | 0.4247 | 0.4247 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.9496 | 0.9496 | 0.9496 | No | 0.1023 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 2.0226 | 2.0226 | 2.0226 | No | 0.4247 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 0.9496 | 0.9496 | 0.9496 | 0.9496 | 0.1023 | 1.0000 |
PSZ-FINE STORAGE | 2.0226 | 2.0226 | 2.0226 | 2.0226 | 0.4247 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.9496 | 0.9496 | 0.9496 | No | 0.1023 | 0.3240 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 2.0226 | 2.0226 | 2.0226 | No | 0.4247 | 0.5617 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 0.9496 | 0.9496 | 0.9496 | 0.9496 | 0.1023 | 1.0000 |
PSZ-FINE STORAGE | 2.0226 | 2.0226 | 2.0226 | 2.0226 | 0.4247 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Buffalo Niagara Intl AP NY USA TMY3 WMO#=725280 |
Total gross floor area [m2] | 4835.13 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
ZONE1 OFFICE | 236.88 | 236.88 | 0.00 | 69.73 |
ZONE2 FINE STORAGE | 1393.41 | 1393.41 | 0.00 | 69.73 |
ZONE3 BULK STORAGE | 3204.84 | 3204.84 | 0.00 | 69.73 |
Totals | 4835.13 | 4835.13 | 0.00 |
Data | |
Number of hours heating loads not met | 28.50 |
Number of hours cooling loads not met | 0.17 |
Number of hours not met | 28.67 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- General | 0.00 | 0.00 | 698.24 | 237586.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- General | 10.02 | 9230.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 93.23 | 9397.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 61.69 | 5492.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 136.51 | 10035.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- Ventilation (simple) | 0.41 | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 29.13 | 2843.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 26.08 | 2690.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 136.51 | 357.06 |
Natural Gas | 0.00 | 698.24 |
Additional | 0.00 | 0.00 |
Total | 136.51 | 1055.30 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 19.28 |
Space Heating | 0.00 |
Space Cooling | 2.07 |
Fans (All) | 6.11 |
Service Water Heating | 5.39 |
Receptacle Equipment | 28.23 |
Miscellaneous (All) | 73.85 |
Subtotal | 73.85 |
Natural Gas [MJ/m2] | |
Space Heating | 144.41 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 144.41 |
Subtotal | 144.41 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 8.83 |
Space Heating | 66.16 |
Space Cooling | 0.95 |
Fans (All) | 2.80 |
Service Water Heating | 2.47 |
Receptacle Equipment | 12.94 |
Miscellaneous | 5.85 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
LTG_SCH_OFFICE | 2499. | 8760. |
LTG_SCH_BULK_STORAGE | 1777. | 8760. |
LTG_SCH_FINE_STORAGE | 1777. | 8760. |
OFFICE_PLUG_SCH | 4298. | 8760. |
BULK STORAGE PLUG SCHEDULE | 3744. | 7488. |
BLDG_OCC_SCH | 2861. | 3744. |
OFFICE PEOPLE SCHEDULE | 2861. | 3744. |
FANSCHED | 3432. | 3432. |
MINOA_MOTORIZEDDAMPER_SCHED | 3120. | 3120. |
OFFICE DHW SCHEDULE | 1825. | 5016. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 5550. | 8760. |
EXTERIOR LIGHT SCHEDULE | 5475. | 5475. |
ALWAYS OFF SCHEDULE | 0. | 0. |
OA DAMPER OFF DURING OFF HRS SCHEDULE | 2808. | 2808. |
OA DAMPER ALWAYS ON SCHEDULE | 8760. | 8760. |
MINOA_SCHED | 8760. | 8760. |
ALWAYS ON SCHEDULE | 8760. | 8760. |
EXTERIOR_LTG_SCH | 4380. | 4380. |
INFIL_DOOR_OPENING_SCH | 1154. | 3380. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 2600. | 2600. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 6935. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
BULK STORAGE HEATING SETPOINT SCHEDULE | ZONE3 BULK STORAGE HEATING SP | January | 10.00 | 365 | 10.00 | 365 |
OFFICE HEATING SCHEDULE | ZONE1 OFFICE DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
OFFICE COOLING SCHEDULE | ZONE1 OFFICE DUAL SP CONTROL | July | 23.90 | 365 | 29.40 | 365 |
FINE STORAGE HEATING SETPOINT SCHEDULE | ZONE2 FINE STORAGE DUAL SP CONTROL | January | 15.56 | 365 | 15.56 | 365 |
FINE STORAGE COOLING SETPOINT SCHEDULE | ZONE2 FINE STORAGE DUAL SP CONTROL | July | 26.70 | 365 | 26.70 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Heat Index HoursSafe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
ZONE1 OFFICE | 8050.00 | 710.00 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 7983.17 | 776.83 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 7680.83 | 1069.33 | 9.83 | 0.00 | 0.00 |
Min | 7680.83 | 710.00 | 0.00 | 0.00 | 0.00 |
Max | 8050.00 | 1069.33 | 9.83 | 0.00 | 0.00 |
Average | 7904.67 | 852.06 | 3.28 | 0.00 | 0.00 |
Sum | 23714.00 | 2556.17 | 9.83 | 0.00 | 0.00 |
Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
ZONE1 OFFICE | 33007.00 | 20.00 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 71093.50 | 11625.50 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 161420.17 | 29220.83 | 552.00 | 0.00 | 0.00 |
Min | 33007.00 | 20.00 | 0.00 | 0.00 | 0.00 |
Max | 161420.17 | 29220.83 | 552.00 | 0.00 | 0.00 |
Average | 88506.89 | 13622.11 | 184.00 | 0.00 | 0.00 |
Sum | 265520.67 | 40866.33 | 552.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
ZONE1 OFFICE | 7636.33 | 1123.67 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 7383.83 | 1376.17 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 7237.33 | 1522.67 | 0.00 | 0.00 | 0.00 |
Min | 7237.33 | 1123.67 | 0.00 | 0.00 | 0.00 |
Max | 7636.33 | 1522.67 | 0.00 | 0.00 | 0.00 |
Average | 7419.17 | 1340.83 | 0.00 | 0.00 | 0.00 |
Sum | 22257.50 | 4022.50 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
ZONE1 OFFICE | 31714.00 | 1313.00 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 66834.00 | 15885.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 153584.33 | 37608.67 | 0.00 | 0.00 | 0.00 |
Min | 31714.00 | 1313.00 | 0.00 | 0.00 | 0.00 |
Max | 153584.33 | 37608.67 | 0.00 | 0.00 | 0.00 |
Average | 84044.11 | 18268.89 | 0.00 | 0.00 | 0.00 |
Sum | 252132.33 | 54806.67 | 0.00 | 0.00 | 0.00 |
SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
None |
SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
CO2 Level HoursSafe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 10:44:03
Illuminance Level HoursA Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
ZONE1 OFFICE | 0.00 | 0.00 | 8760.00 | 0.00 |
ZONE2 FINE STORAGE | 0.00 | 0.00 | 8760.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 8760.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 8760.00 | 8760.00 | 0.00 |
Average | 0.00 | 2920.00 | 5840.00 | 0.00 |
Sum | 0.00 | 8760.00 | 17520.00 | 0.00 |
A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
ZONE1 OFFICE | 0.00 | 0.00 | 33027.00 | 0.00 |
ZONE2 FINE STORAGE | 0.00 | 0.00 | 82719.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 191193.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 191193.00 | 82719.00 | 0.00 |
Average | 0.00 | 63731.00 | 38582.00 | 0.00 |
Sum | 0.00 | 191193.00 | 115746.00 | 0.00 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2021
For: Environment
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
For: Environment
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5A
For: Environment
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_NY_BUFFALO
For: Environment
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -3.40 |
February | -4.23 |
March | 2.667 |
April | 7.472 |
May | 13.731 |
June | 18.627 |
July | 22.029 |
August | 20.690 |
September | 16.545 |
October | 9.725 |
November | 6.035 |
December | -2.18 |
Annual Sum or Average | 9.049 |
Minimum of Months | -4.23 |
Maximum of Months | 22.029 |
Report: ZoneCoolingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 5722831.17 | 2557.02 | 28-JAN-08:05 | -7.9 | -9.2 | 0.492071E+09 | 603.29 | 14-JAN-08:20 | -7.9 | -9.2 |
February | 6338164.30 | 2595.27 | 25-FEB-08:05 | -8.2 | -9.2 | 0.452691E+09 | 603.28 | 15-FEB-08:20 | -8.2 | -9.2 |
March | 14349742.66 | 2708.72 | 04-MAR-08:05 | -9.1 | -10.3 | 0.539217E+09 | 768.97 | 15-MAR-13:50 | 25.92 | 15.99 |
April | 28083591.05 | 1956.64 | 17-APR-07:05 | -2.9 | -4.4 | 0.505211E+09 | 768.44 | 22-APR-15:00 | 16.10 | 7.25 |
May | 0.711524E+09 | 3827.31 | 27-MAY-16:00 | 21.70 | 12.01 | 0.611313E+09 | 768.99 | 10-MAY-15:20 | 21.70 | 12.01 |
June | 0.360161E+10 | 22206.48 | 03-JUN-07:02 | 11.78 | 7.72 | 0.662540E+09 | 879.40 | 12-JUN-07:10 | 24.08 | 18.79 |
July | 0.518007E+10 | 16787.65 | 01-JUL-07:02 | 17.98 | 15.44 | 0.641345E+09 | 879.41 | 15-JUL-07:10 | 23.07 | 19.55 |
August | 0.514801E+10 | 18071.26 | 12-AUG-07:02 | 15.37 | 13.54 | 0.691513E+09 | 879.39 | 26-AUG-07:10 | 19.08 | 18.96 |
September | 0.265203E+10 | 20617.88 | 02-SEP-07:02 | 12.07 | 10.60 | 0.633192E+09 | 879.39 | 16-SEP-07:10 | 21.88 | 19.07 |
October | 0.226344E+09 | 2070.49 | 17-OCT-07:05 | -2.4 | -2.9 | 0.536710E+09 | 768.97 | 11-OCT-15:00 | -2.4 | -2.9 |
November | 6772542.60 | 1939.93 | 24-NOV-08:05 | -2.6 | -3.4 | 0.474056E+09 | 672.51 | 04-NOV-15:00 | -2.6 | -3.4 |
December | 6436227.21 | 2106.64 | 06-DEC-08:05 | -5.0 | -5.2 | 0.492119E+09 | 604.20 | 01-DEC-08:20 | -5.0 | -5.2 |
Annual Sum or Average | 0.175873E+11 | 0.673198E+10 | ||||||||
Minimum of Months | 5722831.17 | 1939.93 | -9.1 | -10.3 | 0.452691E+09 | 603.28 | -8.2 | -9.2 | ||
Maximum of Months | 0.518007E+10 | 22206.48 | 21.70 | 15.44 | 0.691513E+09 | 879.41 | 25.92 | 19.55 |
Report: ZoneCoolingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 85872736.80 | 5743.88 | 13-JAN-13:45 | 1.73 | -1.8 | 0.649474E+09 | 807.10 | 11-JAN-16:10 | 1.73 | -1.8 |
February | 0.312461E+09 | 6613.56 | 23-FEB-12:45 | -0.1 | -1.5 | 0.598031E+09 | 856.50 | 22-FEB-15:50 | -0.1 | -1.5 |
March | 0.202584E+10 | 8128.87 | 27-MAR-09:55 | -3.3 | -4.8 | 0.767554E+09 | 1533.18 | 15-MAR-14:20 | -3.3 | -4.8 |
April | 0.247200E+10 | 5849.96 | 24-APR-07:03 | 3.17 | 1.61 | 0.807234E+09 | 1397.47 | 08-APR-14:20 | 3.17 | 1.61 |
May | 0.210561E+10 | 5320.07 | 08-MAY-07:03 | 5.87 | 1.00 | 0.128397E+10 | 2099.18 | 27-MAY-15:09 | 21.70 | 12.15 |
June | 0.494886E+10 | 32230.47 | 30-JUN-18:02 | 23.12 | 12.20 | 0.180778E+10 | 2246.91 | 27-JUN-14:20 | 23.12 | 12.20 |
July | 0.982072E+10 | 39577.43 | 16-JUL-16:33 | 28.33 | 21.22 | 0.184598E+10 | 2246.92 | 18-JUL-12:30 | 25.55 | 18.79 |
August | 0.824527E+10 | 33167.70 | 10-AUG-17:10 | 28.12 | 19.57 | 0.196521E+10 | 2246.92 | 11-AUG-12:39 | 23.70 | 16.56 |
September | 0.249857E+10 | 7112.38 | 16-SEP-13:40 | 27.20 | 19.70 | 0.161831E+10 | 2246.82 | 22-SEP-14:09 | 23.90 | 15.33 |
October | 0.254879E+10 | 6379.92 | 16-OCT-07:03 | 1.38 | 0.90 | 0.930027E+09 | 1673.46 | 05-OCT-15:09 | 1.38 | 0.90 |
November | 0.178755E+10 | 4941.14 | 18-NOV-12:00 | 4.40 | 1.20 | 0.665727E+09 | 1116.95 | 04-NOV-15:09 | 4.40 | 1.20 |
December | 0.294046E+09 | 4782.85 | 16-DEC-12:00 | 4.40 | 1.70 | 0.651415E+09 | 904.70 | 01-DEC-13:30 | 4.40 | 1.70 |
Annual Sum or Average | 0.371456E+11 | 0.135907E+11 | ||||||||
Minimum of Months | 85872736.80 | 4782.85 | -3.3 | -4.8 | 0.598031E+09 | 807.10 | -3.3 | -4.8 | ||
Maximum of Months | 0.982072E+10 | 39577.43 | 28.33 | 21.22 | 0.196521E+10 | 2246.92 | 25.55 | 18.79 |
Report: ZoneCoolingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | -1.0 | -1.6 | 0.647527E+09 | 958.63 | 11-JAN-16:40 | 11.30 | 9.94 |
February | 0.00 | 0.00 | 01-FEB-00:03 | -3.3 | -4.7 | 0.593927E+09 | 982.93 | 22-FEB-16:00 | 11.70 | 5.56 |
March | 0.00 | 0.00 | 01-MAR-00:03 | -4.9 | -6.9 | 0.860579E+09 | 2128.27 | 15-MAR-14:20 | 25.93 | 16.12 |
April | 0.00 | 0.00 | 01-APR-00:05 | 4.10 | 3.72 | 0.103232E+10 | 1971.41 | 08-APR-14:30 | 20.00 | 13.44 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 6.67 | 6.11 | 0.217376E+10 | 3750.83 | 27-MAY-15:30 | 21.70 | 12.10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 17.05 | 14.04 | 0.361082E+10 | 5795.70 | 27-JUN-13:30 | 28.90 | 23.32 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.82 | 13.50 | 0.472345E+10 | 7143.52 | 21-JUL-14:20 | 31.33 | 22.12 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.85 | 16.93 | 0.502505E+10 | 6700.88 | 10-AUG-14:30 | 30.30 | 20.01 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 14.65 | 12.90 | 0.338779E+10 | 5122.56 | 16-SEP-14:20 | 27.03 | 19.74 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 14.42 | 12.28 | 0.167918E+10 | 3294.19 | 03-OCT-14:00 | 18.90 | 12.68 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 6.53 | 4.43 | 0.818859E+09 | 1697.58 | 04-NOV-15:30 | 18.30 | 13.61 |
December | 0.00 | 0.00 | 01-DEC-00:05 | 4.95 | 3.07 | 0.654803E+09 | 1185.93 | 01-DEC-11:39 | 14.27 | 12.08 |
Annual Sum or Average | 0.00 | 0.252081E+11 | ||||||||
Minimum of Months | 0.00 | 0.00 | -4.9 | -6.9 | 0.593927E+09 | 958.63 | 11.30 | 5.56 | ||
Maximum of Months | 0.00 | 0.00 | 18.85 | 16.93 | 0.502505E+10 | 7143.52 | 31.33 | 23.32 |
Report: ZoneHeatingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.774621E+10 | 26338.30 | 12-JAN-07:01 | -8.5 |
February | 0.705981E+10 | 26746.72 | 06-FEB-06:42 | -13.9 |
March | 0.501288E+10 | 26292.98 | 27-MAR-06:01 | -6.0 |
April | 0.235438E+10 | 26242.15 | 17-APR-06:01 | -4.2 |
May | 0.436647E+09 | 25935.49 | 03-MAY-06:01 | 6.38 |
June | 99803635.24 | 1678.50 | 14-JUN-06:15 | 8.13 |
July | 60511260.16 | 1753.42 | 05-JUL-06:05 | 18.98 |
August | 87437273.63 | 1690.14 | 11-AUG-06:07 | 17.88 |
September | 0.110587E+09 | 1784.38 | 05-SEP-06:13 | 6.67 |
October | 0.117450E+10 | 26052.68 | 30-OCT-06:01 | -0.4 |
November | 0.326786E+10 | 26094.67 | 24-NOV-07:01 | -3.2 |
December | 0.670045E+10 | 27206.32 | 11-DEC-07:02 | -16.4 |
Annual Sum or Average | 0.341111E+11 | |||
Minimum of Months | 60511260.16 | 1678.50 | -16.4 | |
Maximum of Months | 0.774621E+10 | 27206.32 | 18.98 |
Report: ZoneHeatingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.221459E+11 | 75253.64 | 10-JAN-05:23 | -13.3 |
February | 0.205446E+11 | 76239.87 | 06-FEB-22:02 | -15.0 |
March | 0.100449E+11 | 75119.92 | 07-MAR-05:23 | -13.3 |
April | 0.250034E+10 | 51284.81 | 17-APR-02:53 | -2.8 |
May | 99670802.34 | 2339.96 | 01-MAY-06:02 | 2.35 |
June | 63553987.72 | 844.63 | 13-JUN-06:13 | 8.70 |
July | 37232861.53 | 1166.12 | 20-JUL-06:03 | 24.08 |
August | 55097055.78 | 970.08 | 15-AUG-06:04 | 22.30 |
September | 67036426.07 | 869.46 | 05-SEP-06:25 | 6.95 |
October | 0.465238E+09 | 37957.22 | 31-OCT-06:01 | 8.80 |
November | 0.554576E+10 | 67710.44 | 24-NOV-07:01 | -3.2 |
December | 0.200581E+11 | 75910.76 | 26-DEC-06:32 | -12.2 |
Annual Sum or Average | 0.816274E+11 | |||
Minimum of Months | 37232861.53 | 844.63 | -15.0 | |
Maximum of Months | 0.221459E+11 | 76239.87 | 24.08 |
Report: ZoneHeatingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.114214E+12 | 133213.27 | 12-JAN-09:00 | -11.1 |
February | 0.120219E+12 | 133327.57 | 06-FEB-10:00 | -15.0 |
March | 0.422195E+11 | 76897.46 | 05-MAR-01:00 | -7.2 |
April | 0.586067E+10 | 53099.15 | 16-APR-06:53 | -3.9 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 6.67 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 17.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.82 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.85 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 14.65 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 14.42 |
November | 0.984232E+10 | 27718.37 | 25-NOV-06:00 | -1.7 |
December | 0.108536E+12 | 125547.44 | 09-DEC-17:00 | -7.2 |
Annual Sum or Average | 0.400892E+12 | |||
Minimum of Months | 0.00 | 0.00 | -15.0 | |
Maximum of Months | 0.120219E+12 | 133327.57 | 18.85 |
Report: ZoneElectricSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.958122E+09 | 808.57 | 02-JAN-16:49 | 0.244223E+10 | 1835.05 | 02-JAN-08:09 |
February | 0.823495E+09 | 793.61 | 01-FEB-08:09 | 0.222575E+10 | 1835.05 | 01-FEB-08:09 |
March | 0.912831E+09 | 777.16 | 17-MAR-07:10 | 0.253693E+10 | 1835.05 | 01-MAR-08:09 |
April | 0.845034E+09 | 765.64 | 12-APR-07:10 | 0.240164E+10 | 1835.05 | 01-APR-07:10 |
May | 0.857658E+09 | 744.99 | 11-MAY-07:10 | 0.248958E+10 | 1835.05 | 01-MAY-07:10 |
June | 0.816337E+09 | 712.76 | 19-JUN-07:10 | 0.244899E+10 | 1835.05 | 01-JUN-07:10 |
July | 0.821205E+09 | 739.22 | 11-JUL-07:30 | 0.244223E+10 | 1835.05 | 01-JUL-07:10 |
August | 0.866078E+09 | 745.39 | 24-AUG-07:10 | 0.253693E+10 | 1835.05 | 01-AUG-07:10 |
September | 0.849932E+09 | 774.47 | 26-SEP-07:10 | 0.240164E+10 | 1835.05 | 01-SEP-07:10 |
October | 0.902319E+09 | 805.37 | 28-OCT-07:10 | 0.244223E+10 | 1835.05 | 02-OCT-07:10 |
November | 0.923594E+09 | 808.57 | 06-NOV-16:00 | 0.235429E+10 | 1835.05 | 01-NOV-07:10 |
December | 0.967103E+09 | 808.57 | 01-DEC-16:40 | 0.244223E+10 | 1835.05 | 01-DEC-08:09 |
Annual Sum or Average | 0.105437E+11 | 0.291647E+11 | ||||
Minimum of Months | 0.816337E+09 | 712.76 | 0.222575E+10 | 1835.05 | ||
Maximum of Months | 0.967103E+09 | 808.57 | 0.253693E+10 | 1835.05 |
Report: ZoneElectricSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
January | 0.396401E+10 | 4095.95 | 06-JAN-15:00 | 0.00 | 0.00 |
February | 0.326717E+10 | 3883.94 | 01-FEB-09:09 | 0.00 | 0.00 |
March | 0.363538E+10 | 3890.94 | 21-MAR-08:09 | 0.00 | 0.00 |
April | 0.322349E+10 | 3672.56 | 03-APR-08:09 | 0.00 | 0.00 |
May | 0.323288E+10 | 3387.20 | 31-MAY-08:09 | 0.00 | 0.00 |
June | 0.309425E+10 | 3418.30 | 14-JUN-08:09 | 0.00 | 0.00 |
July | 0.307417E+10 | 3455.99 | 13-JUL-08:09 | 0.00 | 0.00 |
August | 0.331146E+10 | 3560.12 | 17-AUG-08:09 | 0.00 | 0.00 |
September | 0.330322E+10 | 3710.41 | 21-SEP-08:09 | 0.00 | 0.00 |
October | 0.361720E+10 | 4045.99 | 31-OCT-08:09 | 0.00 | 0.00 |
November | 0.383623E+10 | 4172.98 | 27-NOV-15:00 | 0.00 | 0.00 |
December | 0.401215E+10 | 4116.91 | 19-DEC-15:00 | 0.00 | 0.00 |
Annual Sum or Average | 0.415716E+11 | 0.00 | 0.00 | ||
Minimum of Months | 0.307417E+10 | 3387.20 | 0.00 | 0.00 | |
Maximum of Months | 0.401215E+10 | 4172.98 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.388229E+10 | 4308.88 | 06-JAN-15:00 | 0.885613E+10 | 8200.12 | 02-JAN-08:09 |
February | 0.325784E+10 | 3949.95 | 01-FEB-16:00 | 0.814764E+10 | 8200.12 | 01-FEB-08:09 |
March | 0.356428E+10 | 3684.92 | 21-MAR-07:10 | 0.957200E+10 | 8200.12 | 01-MAR-08:09 |
April | 0.317994E+10 | 3373.10 | 12-APR-07:10 | 0.885613E+10 | 8200.12 | 01-APR-07:10 |
May | 0.320536E+10 | 2973.46 | 11-MAY-07:10 | 0.921037E+10 | 8200.12 | 01-MAY-07:10 |
June | 0.311078E+10 | 2826.20 | 26-JUN-06:10 | 0.921037E+10 | 8200.12 | 01-JUN-07:10 |
July | 0.309693E+10 | 2990.98 | 21-JUL-06:10 | 0.885613E+10 | 8200.12 | 01-JUL-07:10 |
August | 0.331102E+10 | 3234.36 | 28-AUG-06:10 | 0.956462E+10 | 8200.12 | 01-AUG-07:10 |
September | 0.327693E+10 | 3547.21 | 26-SEP-07:10 | 0.884875E+10 | 8200.12 | 01-SEP-07:10 |
October | 0.354845E+10 | 4173.41 | 31-OCT-07:10 | 0.886351E+10 | 8200.12 | 02-OCT-07:10 |
November | 0.373334E+10 | 4433.29 | 27-NOV-15:00 | 0.850188E+10 | 8200.12 | 01-NOV-07:10 |
December | 0.394347E+10 | 4327.21 | 19-DEC-15:00 | 0.885613E+10 | 8200.12 | 01-DEC-08:09 |
Annual Sum or Average | 0.411106E+11 | 0.107344E+12 | ||||
Minimum of Months | 0.309693E+10 | 2826.20 | 0.814764E+10 | 8200.12 | ||
Maximum of Months | 0.394347E+10 | 4433.29 | 0.957200E+10 | 8200.12 |
Report: SpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.138726E+10 | 0.958122E+09 | 0.244223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.397450E+10 |
February | 0.127628E+10 | 0.823495E+09 | 0.222575E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.375819E+10 |
March | 0.149825E+10 | 0.912831E+09 | 0.253693E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8259788.20 | 0.282954E+10 |
April | 0.138726E+10 | 0.845034E+09 | 0.240164E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.183851E+10 |
May | 0.144276E+10 | 0.857658E+09 | 0.248958E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1650562.20 | 0.120982E+10 |
June | 0.144276E+10 | 0.816337E+09 | 0.244899E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 53599125.44 | 0.819341E+09 |
July | 0.138726E+10 | 0.821205E+09 | 0.244223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146268E+09 | 0.397826E+09 |
August | 0.149825E+10 | 0.866078E+09 | 0.253693E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114855E+09 | 0.607431E+09 |
September | 0.138726E+10 | 0.849932E+09 | 0.240164E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6075839.46 | 0.890189E+09 |
October | 0.138726E+10 | 0.902319E+09 | 0.244223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 486109.53 | 0.158436E+10 |
November | 0.133177E+10 | 0.923594E+09 | 0.235429E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 312435.73 | 0.218483E+10 |
December | 0.138726E+10 | 0.967103E+09 | 0.244223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.368625E+10 |
Annual Sum or Average | 0.168137E+11 | 0.105437E+11 | 0.291647E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.331506E+09 | 0.237808E+11 |
Minimum of Months | 0.127628E+10 | 0.816337E+09 | 0.222575E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.397826E+09 |
Maximum of Months | 0.149825E+10 | 0.967103E+09 | 0.253693E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146268E+09 | 0.397450E+10 |
Report: SpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.326447E+10 | 0.396401E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.499552E+10 |
February | 0.300332E+10 | 0.326717E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.538555E+10 |
March | 0.352563E+10 | 0.363538E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15575894.08 | 0.306490E+10 |
April | 0.326447E+10 | 0.322349E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 106133.93 | 0.208487E+10 |
May | 0.339505E+10 | 0.323288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4428059.79 | 0.138428E+10 |
June | 0.339505E+10 | 0.309425E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12970072.27 | 0.128232E+10 |
July | 0.326447E+10 | 0.307417E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43086348.79 | 0.762681E+09 |
August | 0.352563E+10 | 0.331146E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34159932.90 | 0.900734E+09 |
September | 0.326447E+10 | 0.330322E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 250562.30 | 0.119418E+10 |
October | 0.326447E+10 | 0.361720E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7897944.34 | 0.157177E+10 |
November | 0.313390E+10 | 0.383623E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13644448.74 | 0.223569E+10 |
December | 0.326447E+10 | 0.401215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.518668E+10 |
Annual Sum or Average | 0.395654E+11 | 0.415716E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132119E+09 | 0.300492E+11 |
Minimum of Months | 0.300332E+10 | 0.307417E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.762681E+09 |
Maximum of Months | 0.352563E+10 | 0.401215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43086348.79 | 0.538555E+10 |
Report: SpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.750829E+10 | 0.388229E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10185111.92 | 0.598463E+11 |
February | 0.690763E+10 | 0.325784E+10 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57751653.50 | 0.661206E+11 |
March | 0.810895E+10 | 0.356428E+10 | 0.957200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151939E+10 | 0.335823E+11 |
April | 0.750829E+10 | 0.317994E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.968908E+09 | 0.178705E+11 |
May | 0.780862E+10 | 0.320536E+10 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.656613E+09 | 0.123963E+11 |
June | 0.780862E+10 | 0.311078E+10 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.714849E+09 | 0.151357E+11 |
July | 0.750829E+10 | 0.309693E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27287225.92 | 0.146704E+11 |
August | 0.810895E+10 | 0.331102E+10 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17683898.74 | 0.172320E+11 |
September | 0.750829E+10 | 0.327693E+10 | 0.884875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27089106.45 | 0.164005E+11 |
October | 0.750829E+10 | 0.354845E+10 | 0.886351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.644270E+09 | 0.191121E+11 |
November | 0.720796E+10 | 0.373334E+10 | 0.850188E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157810E+10 | 0.201144E+11 |
December | 0.750829E+10 | 0.394347E+10 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109640E+09 | 0.606497E+11 |
Annual Sum or Average | 0.910005E+11 | 0.411106E+11 | 0.107344E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.633177E+10 | 0.353131E+12 |
Minimum of Months | 0.690763E+10 | 0.309693E+10 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10185111.92 | 0.123963E+11 |
Maximum of Months | 0.810895E+10 | 0.394347E+10 | 0.957200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157810E+10 | 0.661206E+11 |
Report: PeakSpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1680.92 | 02-JAN-08:09 | 808.57 | 02-JAN-16:49 | 1835.05 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 13386.92 | 04-JAN-08:00 |
February | 1680.92 | 01-FEB-08:09 | 793.61 | 01-FEB-08:09 | 1835.05 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 15428.76 | 07-FEB-07:10 |
March | 1680.92 | 01-MAR-08:09 | 777.16 | 17-MAR-07:10 | 1835.05 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 556.19 | 14-MAR-12:00 | 13428.38 | 07-MAR-07:10 |
April | 1680.92 | 01-APR-07:10 | 765.64 | 12-APR-07:10 | 1835.05 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 9331.16 | 17-APR-06:10 |
May | 1680.92 | 01-MAY-07:10 | 744.99 | 11-MAY-07:10 | 1835.05 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 125.91 | 10-MAY-15:10 | 6495.43 | 01-MAY-06:05 |
June | 1680.92 | 01-JUN-07:10 | 712.76 | 19-JUN-07:10 | 1835.05 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2083.67 | 27-JUN-12:00 | 5784.54 | 13-JUN-06:05 |
July | 1680.92 | 01-JUL-07:10 | 739.22 | 11-JUL-07:30 | 1835.05 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2072.04 | 21-JUL-12:00 | 4593.59 | 03-JUL-06:05 |
August | 1680.92 | 01-AUG-07:10 | 745.39 | 24-AUG-07:10 | 1835.05 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2064.20 | 10-AUG-12:00 | 4932.79 | 01-AUG-06:05 |
September | 1680.92 | 01-SEP-07:10 | 774.47 | 26-SEP-07:10 | 1835.05 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 750.43 | 15-SEP-12:00 | 6114.89 | 05-SEP-06:03 |
October | 1680.92 | 02-OCT-07:10 | 805.37 | 28-OCT-07:10 | 1835.05 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 35.59 | 22-OCT-12:00 | 8768.23 | 17-OCT-07:00 |
November | 1680.92 | 01-NOV-07:10 | 808.57 | 06-NOV-16:00 | 1835.05 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 66.06 | 27-NOV-06:10 | 8883.04 | 24-NOV-07:10 |
December | 1680.92 | 01-DEC-08:09 | 808.57 | 01-DEC-16:40 | 1835.05 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 14638.32 | 11-DEC-07:20 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1680.92 | 712.76 | 1835.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4593.59 | |||||
Maximum of Months | 1680.92 | 808.57 | 1835.05 | 0.00 | 0.00 | 0.00 | 0.00 | 2083.67 | 15428.76 |
Report: PeakSpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 3955.50 | 02-JAN-08:09 | 4095.95 | 06-JAN-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 8685.05 | 12-JAN-09:00 |
February | 3955.50 | 01-FEB-08:09 | 3883.94 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 7871.11 | 13-FEB-07:03 |
March | 3955.50 | 01-MAR-08:09 | 3890.94 | 21-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 514.47 | 14-MAR-15:10 | 4112.63 | 03-MAR-18:00 |
April | 3955.50 | 01-APR-07:10 | 3672.56 | 03-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.30 | 08-APR-13:00 | 3859.05 | 04-APR-17:00 |
May | 3955.50 | 01-MAY-07:10 | 3387.20 | 31-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 409.14 | 14-MAY-15:00 | 2260.45 | 11-MAY-15:10 |
June | 3955.50 | 01-JUN-07:10 | 3418.30 | 14-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 486.13 | 12-JUN-15:10 | 2942.62 | 13-JUN-16:00 |
July | 3955.50 | 01-JUL-07:10 | 3455.99 | 13-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 986.71 | 15-JUL-15:10 | 1723.57 | 06-JUL-02:00 |
August | 3955.50 | 01-AUG-07:10 | 3560.12 | 17-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 641.39 | 13-AUG-13:00 | 1647.16 | 30-AUG-18:00 |
September | 3955.50 | 01-SEP-07:10 | 3710.41 | 21-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.75 | 16-SEP-13:00 | 2261.89 | 29-SEP-06:10 |
October | 3955.50 | 02-OCT-07:10 | 4045.99 | 31-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 365.05 | 22-OCT-12:00 | 2223.31 | 23-OCT-15:10 |
November | 3955.50 | 01-NOV-07:10 | 4172.98 | 27-NOV-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 481.98 | 27-NOV-07:01 | 3920.12 | 17-NOV-09:00 |
December | 3955.50 | 01-DEC-08:09 | 4116.91 | 19-DEC-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 7775.88 | 09-DEC-18:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 3955.50 | 3387.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1647.16 | ||||
Maximum of Months | 3955.50 | 4172.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 986.71 | 8685.05 |
Report: PeakSpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 9097.65 | 02-JAN-08:09 | 4308.88 | 06-JAN-15:00 | 8200.12 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2603.57 | 11-JAN-16:00 | 99871.50 | 12-JAN-09:00 |
February | 9097.65 | 01-FEB-08:09 | 3949.95 | 01-FEB-16:00 | 8200.12 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 6139.44 | 22-FEB-18:00 | 98696.24 | 07-FEB-11:00 |
March | 9097.65 | 01-MAR-08:09 | 3684.92 | 21-MAR-07:10 | 8200.12 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 23727.86 | 14-MAR-14:00 | 46855.02 | 01-MAR-15:00 |
April | 9097.65 | 01-APR-07:10 | 3373.10 | 12-APR-07:10 | 8200.12 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14405.07 | 07-APR-14:00 | 34397.53 | 16-APR-06:53 |
May | 9097.65 | 01-MAY-07:10 | 2973.46 | 11-MAY-07:10 | 8200.12 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13824.16 | 14-MAY-15:00 | 22851.61 | 11-MAY-15:00 |
June | 9097.65 | 01-JUN-07:10 | 2826.20 | 26-JUN-06:10 | 8200.12 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10377.18 | 12-JUN-12:10 | 31999.16 | 13-JUN-16:00 |
July | 9097.65 | 01-JUL-07:10 | 2990.98 | 21-JUL-06:10 | 8200.12 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4358.46 | 15-JUL-14:00 | 21606.83 | 06-JUL-02:00 |
August | 9097.65 | 01-AUG-07:10 | 3234.36 | 28-AUG-06:10 | 8200.12 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2397.28 | 13-AUG-12:55 | 21473.75 | 30-AUG-18:00 |
September | 9097.65 | 01-SEP-07:10 | 3547.21 | 26-SEP-07:10 | 8200.12 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2369.73 | 16-SEP-12:10 | 24990.15 | 29-SEP-07:10 |
October | 9097.65 | 02-OCT-07:10 | 4173.41 | 31-OCT-07:10 | 8200.12 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10494.09 | 22-OCT-12:00 | 25811.36 | 23-OCT-15:00 |
November | 9097.65 | 01-NOV-07:10 | 4433.29 | 27-NOV-15:00 | 8200.12 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14617.67 | 27-NOV-06:00 | 29195.43 | 17-NOV-09:00 |
December | 9097.65 | 01-DEC-08:09 | 4327.21 | 19-DEC-15:00 | 8200.12 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 10630.18 | 01-DEC-11:00 | 89548.20 | 09-DEC-15:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 9097.65 | 2826.20 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 2369.73 | 21473.75 | |||||
Maximum of Months | 9097.65 | 4433.29 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 23727.86 | 99871.50 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2557.02 | 28-JAN-08:05 | 6723.69 | 3055.05 | 7340.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 679.13 |
February | 2595.27 | 25-FEB-08:05 | 6723.69 | 2890.66 | 7340.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 754.62 |
March | 2708.72 | 04-MAR-08:05 | 6723.69 | 2917.56 | 7340.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 367.10 |
April | 1956.64 | 17-APR-07:05 | 6723.69 | 2695.29 | 7340.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1561.67 |
May | 3827.31 | 27-MAY-16:00 | 1680.92 | 493.23 | 1835.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.64 |
June | 22206.48 | 03-JUN-07:02 | 8404.61 | 3439.71 | 9175.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 189.37 |
July | 16787.65 | 01-JUL-07:02 | 8404.61 | 3206.77 | 9175.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98.73 |
August | 18071.26 | 12-AUG-07:02 | 8404.61 | 3318.12 | 9175.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 99.07 |
September | 20617.88 | 02-SEP-07:02 | 8404.61 | 3442.19 | 9175.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 144.96 |
October | 2070.49 | 17-OCT-07:05 | 6723.69 | 3028.85 | 7340.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1479.99 |
November | 1939.93 | 24-NOV-08:05 | 6723.69 | 3064.09 | 7340.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1414.51 |
December | 2106.64 | 06-DEC-08:05 | 6723.69 | 3092.06 | 7340.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1888.90 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1939.93 | 1680.92 | 493.23 | 1835.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.64 | |
Maximum of Months | 22206.48 | 8404.61 | 3442.19 | 9175.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1888.90 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5743.88 | 13-JAN-13:45 | 7911.00 | 5899.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 488.45 |
February | 6613.56 | 23-FEB-12:45 | 4192.83 | 4354.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 691.09 |
March | 8128.87 | 27-MAR-09:55 | 7911.00 | 4354.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1186.28 |
April | 5849.96 | 24-APR-07:03 | 11866.50 | 10309.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1061.57 |
May | 5320.07 | 08-MAY-07:03 | 11866.50 | 9722.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1349.70 |
June | 32230.47 | 30-JUN-18:02 | 0.00 | 2625.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 372.29 |
July | 39577.43 | 16-JUL-16:33 | 0.00 | 878.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 131.05 | 0.00 |
August | 33167.70 | 10-AUG-17:10 | 0.00 | 1221.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 126.35 | 0.00 |
September | 7112.38 | 16-SEP-13:40 | 3955.50 | 2177.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.73 | 0.00 |
October | 6379.92 | 16-OCT-07:03 | 11866.50 | 10733.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1051.37 |
November | 4941.14 | 18-NOV-12:00 | 3955.50 | 2810.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 551.02 |
December | 4782.85 | 16-DEC-12:00 | 3955.50 | 3248.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 4782.85 | 0.00 | 878.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 39577.43 | 11866.50 | 10733.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 131.05 | 1349.70 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:03 | 0.00 | 1690.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12639.04 |
February | 0.00 | 01-FEB-00:03 | 0.00 | 1690.51 | 6150.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16974.25 |
March | 0.00 | 01-MAR-00:03 | 0.00 | 1690.51 | 6150.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14959.90 |
April | 0.00 | 01-APR-00:05 | 0.00 | 1127.00 | 4100.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4074.53 |
May | 0.00 | 01-MAY-00:10 | 0.00 | 563.50 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2451.37 |
June | 0.00 | 01-JUN-00:10 | 0.00 | 563.50 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2564.60 |
July | 0.00 | 01-JUL-00:10 | 0.00 | 563.50 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8188.39 |
August | 0.00 | 01-AUG-00:10 | 0.00 | 563.50 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6222.53 |
September | 0.00 | 01-SEP-00:10 | 0.00 | 563.50 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8553.59 |
October | 0.00 | 01-OCT-00:10 | 0.00 | 563.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6080.73 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 563.50 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7587.95 |
December | 0.00 | 01-DEC-00:05 | 0.00 | 1127.00 | 4100.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7796.38 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 563.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2451.37 | |
Maximum of Months | 0.00 | 0.00 | 1690.51 | 6150.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16974.25 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
January | 0.327902E+11 | 28589.29 | 04-JAN-16:00 | 0.194873E+12 | 220456.58 | 12-JAN-08:09 |
February | 0.286472E+11 | 22670.14 | 01-FEB-15:00 | 0.197972E+12 | 237586.76 | 06-FEB-17:19 |
March | 0.308426E+11 | 22099.62 | 21-MAR-07:19 | 0.782894E+11 | 123132.73 | 01-MAR-07:10 |
April | 0.271606E+11 | 21372.64 | 05-APR-07:19 | 0.149302E+11 | 83256.25 | 16-APR-07:10 |
May | 0.270484E+11 | 20473.32 | 24-MAY-07:10 | 0.387761E+09 | 16194.07 | 01-MAY-06:10 |
June | 0.277748E+11 | 26954.56 | 27-JUN-12:50 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 0.307782E+11 | 30366.73 | 19-JUL-14:50 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 0.315088E+11 | 28802.41 | 10-AUG-14:09 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 0.279641E+11 | 23484.73 | 21-SEP-14:00 | 821664.25 | 1369.44 | 29-SEP-07:10 |
October | 0.293303E+11 | 22544.52 | 30-OCT-07:10 | 0.237575E+10 | 27922.32 | 30-OCT-06:10 |
November | 0.302277E+11 | 28301.52 | 17-NOV-16:49 | 0.272852E+11 | 67024.95 | 24-NOV-07:10 |
December | 0.329886E+11 | 28653.47 | 26-DEC-16:00 | 0.182126E+12 | 196480.07 | 09-DEC-16:00 |
Annual Sum or Average | 0.357062E+12 | 0.698239E+12 | ||||
Minimum of Months | 0.270484E+11 | 20473.32 | 0.00 | 0.00 | ||
Maximum of Months | 0.329886E+11 | 30366.73 | 0.197972E+12 | 237586.76 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.880442E+10 | 0.694568E+10 | 0.112984E+11 | 0.00 | 0.345380E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.228798E+10 | 0.00 |
February | 0.734850E+10 | 0.565076E+10 | 0.103734E+11 | 0.00 | 0.318184E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.209276E+10 | 0.00 |
March | 0.811249E+10 | 0.539676E+10 | 0.121089E+11 | 0.00 | 0.286646E+10 | 0.00 | 0.00 | 2802222.78 | 0.00 | 0.00 | 0.00 | 0.235510E+10 | 0.00 |
April | 0.724847E+10 | 0.435435E+10 | 0.112578E+11 | 0.00 | 0.209635E+10 | 0.00 | 0.00 | 5.96 | 0.00 | 0.00 | 0.00 | 0.220362E+10 | 0.00 |
May | 0.729590E+10 | 0.380136E+10 | 0.117000E+11 | 0.00 | 0.197408E+10 | 0.00 | 0.00 | 51771162.59 | 0.00 | 0.00 | 0.00 | 0.222535E+10 | 0.00 |
June | 0.702137E+10 | 0.339148E+10 | 0.116594E+11 | 0.00 | 0.199581E+10 | 0.00 | 0.00 | 0.158708E+10 | 0.00 | 0.00 | 0.00 | 0.211974E+10 | 0.00 |
July | 0.699231E+10 | 0.359336E+10 | 0.112984E+11 | 0.00 | 0.223373E+10 | 0.00 | 0.00 | 0.456389E+10 | 0.00 | 0.00 | 0.00 | 0.209659E+10 | 0.00 |
August | 0.748856E+10 | 0.416746E+10 | 0.121016E+11 | 0.00 | 0.228878E+10 | 0.00 | 0.00 | 0.332557E+10 | 0.00 | 0.00 | 0.00 | 0.213689E+10 | 0.00 |
September | 0.743008E+10 | 0.484868E+10 | 0.112504E+11 | 0.00 | 0.189794E+10 | 0.00 | 0.00 | 0.483134E+09 | 0.00 | 0.00 | 0.00 | 0.205382E+10 | 0.00 |
October | 0.806797E+10 | 0.590099E+10 | 0.113057E+11 | 0.00 | 0.191052E+10 | 0.00 | 0.00 | 1855413.58 | 0.00 | 0.00 | 0.00 | 0.214322E+10 | 0.00 |
November | 0.849316E+10 | 0.648328E+10 | 0.108562E+11 | 0.00 | 0.227458E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.212049E+10 | 0.00 |
December | 0.892272E+10 | 0.715330E+10 | 0.112984E+11 | 0.00 | 0.336555E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.224867E+10 | 0.00 |
Annual Sum or Average | 0.932260E+11 | 0.616875E+11 | 0.136508E+12 | 0.00 | 0.295394E+11 | 0.00 | 0.00 | 0.100161E+11 | 0.00 | 0.00 | 0.00 | 0.260842E+11 | 0.00 |
Minimum of Months | 0.699231E+10 | 0.339148E+10 | 0.103734E+11 | 0.00 | 0.189794E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.205382E+10 | 0.00 |
Maximum of Months | 0.892272E+10 | 0.715330E+10 | 0.121089E+11 | 0.00 | 0.345380E+10 | 0.00 | 0.00 | 0.456389E+10 | 0.00 | 0.00 | 0.00 | 0.235510E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
January | 0.00 | 0.00 | 0.194873E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.197972E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.782894E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.149302E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.387761E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 821664.25 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.237575E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.272852E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.182126E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.698239E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.197972E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 8955.27 | 06-JAN-15:00 | 5492.60 | 01-JAN-06:10 | 10035.17 | 02-JAN-08:09 | 0.00 | 2731.64 | 24-JAN-08:09 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 8482.05 | 01-FEB-09:09 | 5492.60 | 01-FEB-06:10 | 10035.17 | 01-FEB-08:09 | 0.00 | 2843.05 | 07-FEB-08:09 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 8207.13 | 21-MAR-08:09 | 5492.60 | 01-MAR-06:10 | 10035.17 | 01-MAR-08:09 | 0.00 | 2618.28 | 07-MAR-08:09 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 7573.20 | 12-APR-07:10 | 5492.60 | 01-APR-05:10 | 10035.17 | 01-APR-07:10 | 0.00 | 2440.96 | 17-APR-07:10 | 0.00 | 0.00 | 01-APR-00:10 |
May | 6969.06 | 11-MAY-07:10 | 5492.60 | 01-MAY-05:10 | 10035.17 | 01-MAY-07:10 | 0.00 | 1921.61 | 01-MAY-06:10 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 6760.29 | 14-JUN-07:10 | 4946.68 | 01-JUN-19:49 | 10035.17 | 01-JUN-07:10 | 0.00 | 1917.11 | 17-JUN-15:20 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 6871.21 | 13-JUL-07:10 | 4946.68 | 01-JUL-19:00 | 10035.17 | 01-JUL-07:10 | 0.00 | 4301.52 | 19-JUL-14:30 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 7225.94 | 17-AUG-07:10 | 5492.60 | 02-AUG-05:10 | 10035.17 | 01-AUG-07:10 | 0.00 | 4222.41 | 18-AUG-15:50 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 7837.28 | 26-SEP-07:10 | 5492.60 | 01-SEP-05:10 | 10035.17 | 01-SEP-07:10 | 0.00 | 1917.11 | 15-SEP-14:20 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 8804.85 | 31-OCT-08:09 | 5492.60 | 01-OCT-05:10 | 10035.17 | 02-OCT-07:10 | 0.00 | 2081.04 | 30-OCT-07:10 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 9397.46 | 27-NOV-15:00 | 5492.60 | 01-NOV-05:10 | 10035.17 | 01-NOV-07:10 | 0.00 | 2469.85 | 24-NOV-08:09 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 9227.97 | 19-DEC-15:00 | 5492.60 | 01-DEC-06:10 | 10035.17 | 01-DEC-08:09 | 0.00 | 2757.90 | 26-DEC-08:09 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||||
Minimum of Months | 6760.29 | 4946.68 | 10035.17 | 0.00 | 1917.11 | 0.00 | 0.00 | |||||
Maximum of Months | 9397.46 | 5492.60 | 10035.17 | 0.00 | 4301.52 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 2676.10 | 31-JAN-12:00 | 0.00 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 2690.68 | 16-FEB-12:09 | 0.00 |
March | 296.84 | 15-MAR-14:39 | 0.00 | 0.00 | 0.00 | 2675.89 | 02-MAR-12:30 | 0.00 |
April | 0.01 | 22-APR-15:00 | 0.00 | 0.00 | 0.00 | 2552.90 | 03-APR-11:00 | 0.00 |
May | 893.80 | 10-MAY-14:00 | 0.00 | 0.00 | 0.00 | 2354.20 | 01-MAY-11:09 | 0.00 |
June | 8264.77 | 27-JUN-12:00 | 0.00 | 0.00 | 0.00 | 2064.93 | 01-JUN-11:20 | 0.00 |
July | 9230.63 | 19-JUL-14:39 | 0.00 | 0.00 | 0.00 | 1805.35 | 01-JUL-11:09 | 0.00 |
August | 7729.47 | 10-AUG-13:00 | 0.00 | 0.00 | 0.00 | 1793.06 | 01-AUG-11:09 | 0.00 |
September | 4594.06 | 16-SEP-13:39 | 0.00 | 0.00 | 0.00 | 1804.55 | 30-SEP-11:09 | 0.00 |
October | 241.66 | 11-OCT-14:00 | 0.00 | 0.00 | 0.00 | 2063.31 | 31-OCT-11:00 | 0.00 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 2312.34 | 27-NOV-12:00 | 0.00 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 2536.58 | 27-DEC-12:00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1793.06 | 0.00 | ||
Maximum of Months | 9230.63 | 0.00 | 0.00 | 0.00 | 2690.68 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 28589.29 | 04-JAN-16:00 | 8876.89 | 10035.17 | 5492.60 | 0.00 | 2563.44 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 22670.14 | 01-FEB-15:00 | 8454.36 | 10035.17 | 0.00 | 0.00 | 2342.88 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 22099.62 | 21-MAR-07:19 | 7953.76 | 10035.17 | 0.00 | 0.00 | 2451.16 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 21372.64 | 05-APR-07:19 | 7320.38 | 10035.17 | 0.00 | 0.00 | 2360.52 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 20473.32 | 24-MAY-07:10 | 6877.68 | 10035.17 | 0.00 | 0.00 | 1917.11 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 26954.56 | 27-JUN-12:50 | 5091.56 | 10035.17 | 0.00 | 0.00 | 1917.11 | 0.00 | 0.00 | 8142.57 | 0.00 |
July | 30366.73 | 19-JUL-14:50 | 5065.28 | 10035.17 | 0.00 | 0.00 | 4291.59 | 0.00 | 0.00 | 9215.29 | 0.00 |
August | 28802.41 | 10-AUG-14:09 | 5065.28 | 10035.17 | 0.00 | 0.00 | 4222.41 | 0.00 | 0.00 | 7725.00 | 0.00 |
September | 23484.73 | 21-SEP-14:00 | 6411.60 | 10035.17 | 0.00 | 0.00 | 1917.11 | 0.00 | 0.00 | 3358.79 | 0.00 |
October | 22544.52 | 30-OCT-07:10 | 8787.18 | 10035.17 | 0.00 | 0.00 | 2081.04 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 28301.52 | 17-NOV-16:49 | 8876.89 | 10035.17 | 5492.60 | 0.00 | 2284.04 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 28653.47 | 26-DEC-16:00 | 8876.89 | 10035.17 | 5492.60 | 0.00 | 2628.83 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 20473.32 | 5065.28 | 10035.17 | 0.00 | 0.00 | 1917.11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 30366.73 | 8876.89 | 10035.17 | 5492.60 | 0.00 | 4291.59 | 0.00 | 0.00 | 9215.29 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | |
January | 0.00 | 0.00 | 220456.58 | 12-JAN-08:09 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 237586.76 | 06-FEB-17:19 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 123132.73 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 83256.25 | 16-APR-07:10 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 16194.07 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 1369.44 | 29-SEP-07:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 27922.32 | 30-OCT-06:10 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 67024.95 | 24-NOV-07:10 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 196480.07 | 09-DEC-16:00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 237586.76 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 8.83 | 15.88 | 4.50 | 16.16 | 0.00 | 16.16 | 0.00 | 16.16 |
February | 9.00 | 15.96 | 4.67 | 16.27 | 0.00 | 16.27 | 0.00 | 16.27 |
March | 5.67 | 16.31 | 3.67 | 16.60 | 0.00 | 16.60 | 0.00 | 16.60 |
April | 1.67 | 16.73 | 1.50 | 16.82 | 0.00 | 16.82 | 0.00 | 16.82 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.48 | 0.17 | 24.48 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.83 | 17.21 | 0.83 | 17.21 | 0.00 | 17.21 | 0.00 | 17.21 |
November | 0.67 | 17.56 | 0.67 | 17.56 | 0.00 | 17.56 | 0.00 | 17.56 |
December | 6.17 | 16.38 | 4.00 | 16.67 | 0.00 | 16.67 | 0.00 | 16.67 |
Annual Sum or Average | 32.83 | 16.18 | 19.83 | 16.47 | 0.17 | 16.50 | 0.17 | 16.52 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 9.00 | 17.56 | 4.67 | 17.56 | 0.17 | 24.48 | 0.17 | 24.48 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 97.83 | 14.70 | 4.33 | 14.69 | 0.00 | 14.69 | 0.00 | 14.69 |
February | 89.17 | 14.66 | 4.00 | 14.66 | 0.00 | 14.66 | 0.00 | 14.66 |
March | 45.00 | 14.78 | 4.00 | 14.78 | 0.00 | 14.78 | 0.00 | 14.78 |
April | 7.33 | 14.93 | 0.17 | 14.93 | 0.00 | 14.93 | 0.00 | 14.93 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 27.27 | 0.00 | 27.27 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 6.50 | 27.33 | 0.00 | 27.33 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 4.83 | 27.31 | 0.00 | 27.31 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.83 | 14.98 | 0.00 | 14.98 | 0.00 | 14.98 | 0.00 | 14.98 |
November | 11.67 | 14.93 | 0.67 | 14.93 | 0.00 | 14.93 | 0.00 | 14.93 |
December | 76.83 | 14.70 | 4.17 | 14.70 | 0.00 | 14.70 | 0.00 | 14.70 |
Annual Sum or Average | 328.67 | 14.71 | 17.33 | 14.71 | 12.67 | 15.16 | 0.00 | 15.16 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 97.83 | 14.98 | 4.33 | 14.98 | 6.50 | 27.33 | 0.00 | 27.33 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.67 | 9.43 | 0.67 | 9.43 | 0.00 | 9.43 | 0.00 | 9.43 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.67 | 9.43 | 0.67 | 9.43 | 0.00 | 9.43 | 0.00 | 9.43 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.67 | 9.43 | 0.67 | 9.43 | 0.00 | 9.43 | 0.00 | 9.43 |
Report: ComfortReportSimple55Monthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 300.00 | 20.62 | 300.00 | 20.62 | 300.00 | 20.62 |
February | 276.00 | 20.62 | 276.00 | 20.62 | 276.00 | 20.62 |
March | 324.00 | 20.77 | 295.33 | 20.69 | 295.33 | 20.67 |
April | 300.00 | 20.89 | 255.83 | 20.77 | 255.83 | 20.72 |
May | 303.83 | 22.59 | 64.67 | 22.25 | 63.83 | 22.00 |
June | 88.17 | 23.87 | 182.67 | 24.13 | 34.83 | 24.16 |
July | 76.50 | 24.66 | 299.67 | 24.39 | 76.50 | 24.44 |
August | 48.33 | 24.80 | 306.00 | 24.36 | 47.33 | 24.41 |
September | 111.33 | 23.65 | 120.17 | 23.94 | 28.17 | 23.99 |
October | 300.00 | 21.56 | 162.33 | 21.23 | 162.33 | 21.07 |
November | 288.00 | 20.67 | 279.67 | 20.65 | 279.67 | 20.65 |
December | 300.00 | 20.62 | 300.00 | 20.62 | 300.00 | 20.62 |
Annual Sum or Average | 2716.17 | 21.42 | 2842.33 | 21.61 | 2119.83 | 21.43 |
Minimum of Months | 48.33 | 20.62 | 64.67 | 20.62 | 28.17 | 20.62 |
Maximum of Months | 324.00 | 24.80 | 306.00 | 24.39 | 300.00 | 24.44 |
Report: ComfortReportSimple55Monthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 300.00 | 15.55 | 300.00 | 15.55 | 300.00 | 15.55 |
February | 276.00 | 15.55 | 276.00 | 15.55 | 276.00 | 15.55 |
March | 324.00 | 16.18 | 314.33 | 16.10 | 314.33 | 16.08 |
April | 300.00 | 17.19 | 298.17 | 17.18 | 298.17 | 17.18 |
May | 277.50 | 20.93 | 127.50 | 20.63 | 108.17 | 20.30 |
June | 150.83 | 25.74 | 259.50 | 25.96 | 117.83 | 26.06 |
July | 236.33 | 26.70 | 300.00 | 26.64 | 236.33 | 26.65 |
August | 216.33 | 26.58 | 320.17 | 26.47 | 216.33 | 26.50 |
September | 150.50 | 24.02 | 190.00 | 24.92 | 67.33 | 25.02 |
October | 300.00 | 18.49 | 229.83 | 18.11 | 229.83 | 17.97 |
November | 288.00 | 16.00 | 288.00 | 16.00 | 288.00 | 16.00 |
December | 300.00 | 15.57 | 300.00 | 15.57 | 300.00 | 15.57 |
Annual Sum or Average | 3119.50 | 19.09 | 3203.50 | 19.39 | 2752.33 | 19.17 |
Minimum of Months | 150.50 | 15.55 | 127.50 | 15.55 | 67.33 | 15.55 |
Maximum of Months | 324.00 | 26.70 | 320.17 | 26.64 | 314.33 | 26.65 |
Report: ComfortReportSimple55Monthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 300.00 | 10.03 | 300.00 | 10.03 | 300.00 | 10.03 |
February | 276.00 | 10.01 | 276.00 | 10.01 | 276.00 | 10.01 |
March | 324.00 | 11.01 | 324.00 | 11.01 | 324.00 | 11.01 |
April | 300.00 | 12.56 | 300.00 | 12.56 | 300.00 | 12.56 |
May | 312.00 | 18.20 | 267.17 | 17.94 | 267.17 | 17.85 |
June | 249.33 | 23.41 | 150.67 | 24.12 | 96.83 | 24.33 |
July | 244.50 | 28.41 | 300.00 | 28.16 | 244.50 | 28.24 |
August | 270.83 | 28.09 | 321.17 | 27.92 | 270.83 | 27.97 |
September | 194.67 | 22.91 | 123.00 | 23.49 | 52.83 | 23.51 |
October | 300.00 | 16.25 | 287.33 | 16.15 | 287.33 | 16.12 |
November | 288.00 | 11.44 | 288.00 | 11.44 | 288.00 | 11.44 |
December | 300.00 | 10.07 | 300.00 | 10.07 | 300.00 | 10.07 |
Annual Sum or Average | 3359.33 | 16.32 | 3237.33 | 16.33 | 3007.50 | 16.11 |
Minimum of Months | 194.67 | 10.01 | 123.00 | 10.01 | 52.83 | 10.01 |
Maximum of Months | 324.00 | 28.41 | 324.00 | 28.16 | 324.00 | 28.24 |
Report: OccupantComfortDataSummaryMonthly
For: OFFICE PEOPLE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: ZONE2 FINE STORAGEPEOPLE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: ZONE3 BULK STORAGEPEOPLE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 12456550.29 | 2802222.78 | 3.17 | 11650571.64 | 805978.65 | 0.00 | 0.16 | 15-MAR-14:40 | 0.00 | 01-MAR-00:03 | 1318.76 | 15-MAR-14:40 | 1238.87 | 15-MAR-14:20 | 101.03 | 15-MAR-16:00 | 296.84 | 15-MAR-14:40 | 0.00 | 01-MAR-00:03 |
April | 26.58 | 5.96 | 0.17 | 26.58 | 0.00 | 0.00 | 0.00 | 22-APR-16:00 | 0.00 | 01-APR-00:05 | 0.04 | 22-APR-16:00 | 0.04 | 22-APR-16:00 | 0.00 | 22-APR-16:00 | 0.01 | 22-APR-16:00 | 0.00 | 01-APR-00:05 |
May | 0.242371E+09 | 51771162.59 | 35.75 | 0.232758E+09 | 9613211.92 | 0.00 | 0.50 | 23-MAY-14:50 | 0.00 | 01-MAY-00:10 | 4224.13 | 23-MAY-14:50 | 4224.13 | 23-MAY-14:50 | 695.09 | 10-MAY-15:10 | 893.80 | 10-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.328793E+10 | 0.662791E+09 | 169.96 | 0.257676E+10 | 0.711164E+09 | 0.00 | 1.00 | 02-JUN-07:03 | 0.00 | 01-JUN-00:10 | 20995.53 | 27-JUN-07:02 | 13681.12 | 12-JUN-07:02 | 10392.77 | 27-JUN-07:02 | 4052.85 | 27-JUN-07:02 | 0.00 | 01-JUN-00:10 |
July | 0.742570E+10 | 0.147344E+10 | 250.31 | 0.537744E+10 | 0.204825E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:10 | 21511.23 | 21-JUL-06:02 | 14064.00 | 15-JUL-06:02 | 11786.91 | 29-JUL-07:02 | 4181.52 | 21-JUL-06:02 | 0.00 | 01-JUL-00:10 |
August | 0.606366E+10 | 0.121741E+10 | 246.84 | 0.491557E+10 | 0.114809E+10 | 0.00 | 1.00 | 03-AUG-16:08 | 0.00 | 01-AUG-00:10 | 21383.55 | 14-AUG-07:03 | 13997.94 | 18-AUG-07:02 | 11494.30 | 14-AUG-07:03 | 4099.41 | 14-AUG-07:03 | 0.00 | 01-AUG-00:10 |
September | 0.187066E+10 | 0.380417E+09 | 130.37 | 0.144658E+10 | 0.424073E+09 | 0.00 | 1.00 | 02-SEP-07:02 | 0.00 | 01-SEP-00:10 | 19899.46 | 14-SEP-07:02 | 12081.32 | 02-SEP-07:02 | 9703.93 | 14-SEP-07:04 | 3907.67 | 14-SEP-07:02 | 0.00 | 01-SEP-00:10 |
October | 8413501.96 | 1855413.58 | 3.83 | 8287198.89 | 126303.07 | 0.00 | 0.14 | 11-OCT-15:00 | 0.00 | 01-OCT-00:10 | 1100.42 | 11-OCT-15:00 | 1084.19 | 11-OCT-15:00 | 38.10 | 11-OCT-16:00 | 241.66 | 11-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.189112E+11 | 0.379049E+10 | 840.40 | 0.145691E+11 | 0.434213E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.742570E+10 | 0.147344E+10 | 250.31 | 0.537744E+10 | 0.204825E+10 | 0.00 | 1.00 | 0.00 | 21511.23 | 14064.00 | 11786.91 | 4181.52 | 0.00 |
Report: DXReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {Maximum} [W] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 | 0.00 | 01-JAN-00:03 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 | 0.00 | 01-FEB-00:03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 | 0.00 | 01-APR-00:05 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 | 0.00 | 01-MAY-00:10 |
June | 0.387273E+10 | 0.924289E+09 | 97.79 | 0.272732E+10 | 0.114541E+10 | 0.00 | 1.00 | 11-JUN-13:15 | 0.00 | 01-JUN-00:10 | 57407.57 | 27-JUN-17:13 | 44811.42 | 30-JUN-17:13 | 29152.90 | 27-JUN-19:35 | 12501.31 | 27-JUN-17:13 | 0.00 | 01-JUN-00:10 |
July | 0.130890E+11 | 0.309044E+10 | 257.42 | 0.892103E+10 | 0.416802E+10 | 0.00 | 1.00 | 01-JUL-17:25 | 0.00 | 01-JUL-00:10 | 58982.28 | 20-JUL-23:05 | 45032.10 | 06-JUL-18:05 | 32315.67 | 20-JUL-22:05 | 12744.80 | 21-JUL-00:05 | 0.00 | 01-JUL-00:10 |
August | 0.868815E+10 | 0.210817E+10 | 207.70 | 0.680889E+10 | 0.187926E+10 | 0.00 | 1.00 | 01-AUG-17:13 | 0.00 | 01-AUG-00:10 | 55705.65 | 13-AUG-18:25 | 45942.91 | 03-AUG-18:45 | 25655.80 | 07-AUG-17:22 | 12317.90 | 13-AUG-17:35 | 0.00 | 01-AUG-00:10 |
September | 0.405871E+09 | 0.102717E+09 | 23.50 | 0.292335E+09 | 0.113535E+09 | 0.00 | 0.49 | 16-SEP-13:40 | 0.00 | 01-SEP-00:10 | 11584.38 | 16-SEP-13:40 | 8222.91 | 16-SEP-13:40 | 3455.97 | 15-SEP-12:10 | 2892.75 | 16-SEP-13:40 | 0.00 | 01-SEP-00:10 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.260558E+11 | 0.622562E+10 | 586.41 | 0.187496E+11 | 0.730622E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.130890E+11 | 0.309044E+10 | 257.42 | 0.892103E+10 | 0.416802E+10 | 0.00 | 1.00 | 0.00 | 58982.28 | 45942.91 | 32315.67 | 12744.80 | 0.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 48.81 | 11.50 | 37.32 | 16.78 | 148.48 | 0.00 | 0.00 | 0.00 |
February | 79.09 | 20.41 | 58.68 | 41.18 | 139.08 | 0.00 | 0.00 | 0.00 |
March | 124.34 | 53.45 | 70.89 | 113.87 | 91.27 | 0.00 | 0.00 | 0.00 |
April | 151.25 | 61.91 | 89.35 | 161.51 | 63.04 | 0.00 | 0.00 | 0.00 |
May | 178.56 | 80.63 | 97.93 | 209.68 | 47.72 | 0.00 | 0.00 | 0.00 |
June | 215.73 | 101.49 | 114.24 | 267.71 | 42.46 | 0.00 | 0.00 | 0.00 |
July | 192.64 | 84.34 | 108.30 | 250.81 | 33.72 | 0.00 | 0.00 | 0.00 |
August | 174.05 | 73.81 | 100.23 | 223.15 | 42.58 | 0.00 | 0.00 | 0.00 |
September | 137.04 | 59.21 | 77.83 | 160.12 | 58.84 | 0.00 | 0.00 | 0.00 |
October | 88.80 | 31.28 | 57.52 | 87.51 | 69.26 | 0.00 | 0.00 | 0.00 |
November | 52.20 | 14.82 | 37.38 | 38.52 | 85.15 | 0.00 | 0.00 | 0.00 |
December | 45.53 | 9.87 | 35.67 | 15.98 | 142.34 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 124.21 | 50.37 | 73.84 | 132.71 | 80.04 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 45.53 | 9.87 | 35.67 | 15.98 | 33.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 215.73 | 101.49 | 114.24 | 267.71 | 148.48 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 48.81 | 11.50 | 37.32 | 16.78 | 148.48 | 0.00 | 0.00 | 0.00 |
February | 79.09 | 20.41 | 58.68 | 41.18 | 139.08 | 0.00 | 0.00 | 0.00 |
March | 124.34 | 53.45 | 70.89 | 113.87 | 91.27 | 0.00 | 0.00 | 0.00 |
April | 151.25 | 61.91 | 89.35 | 161.51 | 63.04 | 0.00 | 0.00 | 0.00 |
May | 178.56 | 80.63 | 97.93 | 209.68 | 47.72 | 0.00 | 0.00 | 0.00 |
June | 215.73 | 101.49 | 114.24 | 267.71 | 42.46 | 0.00 | 0.00 | 0.00 |
July | 192.64 | 84.34 | 108.30 | 250.81 | 33.72 | 0.00 | 0.00 | 0.00 |
August | 174.05 | 73.81 | 100.23 | 223.15 | 42.58 | 0.00 | 0.00 | 0.00 |
September | 137.04 | 59.21 | 77.83 | 160.12 | 58.84 | 0.00 | 0.00 | 0.00 |
October | 88.80 | 31.28 | 57.52 | 87.51 | 69.26 | 0.00 | 0.00 | 0.00 |
November | 52.20 | 14.82 | 37.38 | 38.52 | 85.15 | 0.00 | 0.00 | 0.00 |
December | 45.53 | 9.87 | 35.67 | 15.98 | 142.34 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 124.21 | 50.37 | 73.84 | 132.71 | 80.04 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 45.53 | 9.87 | 35.67 | 15.98 | 33.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 215.73 | 101.49 | 114.24 | 267.71 | 148.48 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 18.10 | 0.00 | 18.10 | 0.62 | 92.50 | 0.00 | 0.00 | 0.00 |
February | 27.58 | 0.00 | 27.58 | 3.37 | 85.88 | 0.00 | 0.00 | 0.00 |
March | 33.45 | 0.00 | 33.45 | 15.47 | 57.23 | 0.00 | 0.00 | 0.00 |
April | 42.64 | 0.21 | 42.44 | 30.98 | 37.22 | 0.00 | 0.00 | 0.00 |
May | 49.54 | 2.13 | 47.41 | 45.51 | 26.51 | 0.00 | 0.00 | 0.00 |
June | 59.56 | 5.06 | 54.50 | 63.55 | 23.14 | 0.00 | 0.00 | 0.00 |
July | 55.47 | 3.77 | 51.70 | 66.33 | 18.36 | 0.00 | 0.00 | 0.00 |
August | 48.02 | 0.93 | 47.10 | 54.13 | 24.04 | 0.00 | 0.00 | 0.00 |
September | 36.40 | 0.02 | 36.38 | 32.60 | 34.97 | 0.00 | 0.00 | 0.00 |
October | 27.20 | 0.00 | 27.20 | 17.14 | 41.62 | 0.00 | 0.00 | 0.00 |
November | 18.28 | 0.00 | 18.28 | 6.62 | 51.12 | 0.00 | 0.00 | 0.00 |
December | 16.94 | 0.00 | 16.94 | 0.69 | 87.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 36.13 | 1.01 | 35.12 | 28.23 | 48.17 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 16.94 | 0.00 | 16.94 | 0.62 | 18.36 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 59.56 | 5.06 | 54.50 | 66.33 | 92.50 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 18.10 | 0.00 | 18.10 | 0.62 | 92.50 | 0.00 | 0.00 | 0.00 |
February | 27.58 | 0.00 | 27.58 | 3.37 | 85.88 | 0.00 | 0.00 | 0.00 |
March | 33.45 | 0.00 | 33.45 | 15.47 | 57.23 | 0.00 | 0.00 | 0.00 |
April | 42.64 | 0.21 | 42.44 | 30.97 | 37.22 | 0.00 | 0.00 | 0.00 |
May | 49.54 | 2.13 | 47.40 | 45.51 | 26.51 | 0.00 | 0.00 | 0.00 |
June | 59.56 | 5.06 | 54.49 | 63.55 | 23.14 | 0.00 | 0.00 | 0.00 |
July | 55.47 | 3.77 | 51.70 | 66.33 | 18.36 | 0.00 | 0.00 | 0.00 |
August | 48.02 | 0.93 | 47.10 | 54.12 | 24.04 | 0.00 | 0.00 | 0.00 |
September | 36.40 | 0.02 | 36.38 | 32.60 | 34.97 | 0.00 | 0.00 | 0.00 |
October | 27.20 | 0.00 | 27.20 | 17.14 | 41.62 | 0.00 | 0.00 | 0.00 |
November | 18.27 | 0.00 | 18.27 | 6.62 | 51.12 | 0.00 | 0.00 | 0.00 |
December | 16.94 | 0.00 | 16.94 | 0.69 | 87.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 36.13 | 1.01 | 35.12 | 28.23 | 48.17 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 16.94 | 0.00 | 16.94 | 0.62 | 18.36 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 59.56 | 5.06 | 54.49 | 66.33 | 92.50 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 20.38 | 73.18 | 0.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 42.50 | 70.34 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 90.04 | 48.72 | 4.83 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 130.79 | 33.70 | 0.33 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 174.56 | 27.87 | 1.67 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 205.95 | 26.66 | 0.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.95 | 22.16 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 164.84 | 26.72 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 115.25 | 35.01 | 0.83 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 66.30 | 36.74 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 31.81 | 42.66 | 0.00 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 16.96 | 69.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 105.03 | 42.61 | 7.67 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 16.96 | 22.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 205.95 | 73.18 | 4.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_6
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 20.38 | 73.18 | 0.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 42.50 | 70.34 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 90.04 | 48.72 | 4.83 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 130.79 | 33.70 | 0.33 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 174.56 | 27.87 | 1.67 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 205.95 | 26.66 | 0.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.95 | 22.16 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 164.84 | 26.72 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 115.25 | 35.01 | 0.83 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 66.30 | 36.74 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 31.81 | 42.66 | 0.00 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 16.96 | 69.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 105.03 | 42.61 | 7.67 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 16.96 | 22.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 205.95 | 73.18 | 4.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_7
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 20.38 | 73.18 | 0.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 42.50 | 70.34 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 90.04 | 48.72 | 4.83 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 130.79 | 33.70 | 0.33 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 174.56 | 27.87 | 1.67 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 205.95 | 26.66 | 0.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.95 | 22.16 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 164.84 | 26.72 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 115.25 | 35.01 | 0.83 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 66.30 | 36.74 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 31.81 | 42.66 | 0.00 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 16.96 | 69.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 105.03 | 42.61 | 7.67 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 16.96 | 22.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 205.95 | 73.18 | 4.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_8
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 20.38 | 73.18 | 0.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 42.50 | 70.34 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 90.04 | 48.72 | 4.83 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 130.79 | 33.70 | 0.33 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 174.56 | 27.87 | 1.67 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 205.95 | 26.66 | 0.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.95 | 22.16 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 164.84 | 26.72 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 115.25 | 35.01 | 0.83 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 66.30 | 36.74 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 31.81 | 42.66 | 0.00 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 16.96 | 69.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 105.03 | 42.61 | 7.67 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 16.96 | 22.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 205.95 | 73.18 | 4.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_9
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 20.38 | 73.18 | 0.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 42.50 | 70.34 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 90.04 | 48.72 | 4.83 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 130.79 | 33.70 | 0.33 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 174.56 | 27.87 | 1.67 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 205.95 | 26.66 | 0.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.95 | 22.16 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 164.84 | 26.72 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 115.25 | 35.01 | 0.83 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 66.30 | 36.74 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 31.81 | 42.66 | 0.00 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 16.96 | 69.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 105.03 | 42.61 | 7.67 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 16.96 | 22.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 205.95 | 73.18 | 4.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_10
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 20.38 | 73.18 | 0.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 42.50 | 70.34 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 90.04 | 48.72 | 4.83 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 130.79 | 33.70 | 0.33 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 174.56 | 27.87 | 1.67 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 205.95 | 26.66 | 0.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.95 | 22.16 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 164.84 | 26.72 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 115.25 | 35.01 | 0.83 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 66.30 | 36.74 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 31.81 | 42.66 | 0.00 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 16.96 | 69.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 105.03 | 42.61 | 7.67 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 16.96 | 22.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 205.95 | 73.18 | 4.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_5
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 20.38 | 73.18 | 0.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 42.50 | 70.34 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 90.04 | 48.72 | 4.83 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 130.79 | 33.70 | 0.33 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 174.56 | 27.87 | 1.67 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 205.95 | 26.66 | 0.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.95 | 22.16 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 164.84 | 26.72 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 115.25 | 35.01 | 0.83 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 66.30 | 36.74 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 31.81 | 42.66 | 0.00 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 16.96 | 69.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 105.03 | 42.61 | 7.67 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 16.96 | 22.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 205.95 | 73.18 | 4.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 20.38 | 73.18 | 0.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 42.50 | 70.34 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 90.04 | 48.72 | 4.83 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 130.79 | 33.70 | 0.33 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 174.56 | 27.87 | 1.67 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 205.95 | 26.66 | 0.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.95 | 22.16 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 164.84 | 26.72 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 115.25 | 35.01 | 0.83 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 66.30 | 36.74 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 31.81 | 42.66 | 0.00 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 16.96 | 69.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 105.03 | 42.61 | 7.67 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 16.96 | 22.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 205.95 | 73.18 | 4.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 20.38 | 73.18 | 0.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 42.50 | 70.34 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 90.04 | 48.72 | 4.83 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 130.79 | 33.70 | 0.33 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 174.56 | 27.87 | 1.67 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 205.95 | 26.66 | 0.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.95 | 22.16 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 164.84 | 26.72 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 115.25 | 35.01 | 0.83 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 66.30 | 36.74 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 31.81 | 42.66 | 0.00 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 16.96 | 69.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 105.03 | 42.61 | 7.67 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 16.96 | 22.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 205.95 | 73.18 | 4.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 20.38 | 73.18 | 0.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 42.50 | 70.34 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 90.04 | 48.72 | 4.83 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 130.79 | 33.70 | 0.33 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 174.56 | 27.87 | 1.67 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 205.95 | 26.66 | 0.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.95 | 22.16 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 164.84 | 26.72 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 115.25 | 35.01 | 0.83 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 66.30 | 36.74 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 31.81 | 42.66 | 0.00 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 16.96 | 69.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 105.03 | 42.61 | 7.67 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 16.96 | 22.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 205.95 | 73.18 | 4.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_14
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 20.38 | 73.18 | 0.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 42.50 | 70.34 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 90.04 | 48.72 | 4.83 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 130.79 | 33.70 | 0.33 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 174.56 | 27.87 | 1.67 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 205.95 | 26.66 | 0.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.95 | 22.16 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 164.84 | 26.72 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 115.25 | 35.01 | 0.83 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 66.30 | 36.74 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 31.81 | 42.66 | 0.00 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 16.96 | 69.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 105.03 | 42.61 | 7.67 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 16.96 | 22.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 205.95 | 73.18 | 4.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_13
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 20.38 | 73.18 | 0.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 42.50 | 70.34 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 90.04 | 48.72 | 4.83 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 130.79 | 33.70 | 0.33 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 174.56 | 27.87 | 1.67 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 205.95 | 26.66 | 0.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.95 | 22.16 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 164.84 | 26.72 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 115.25 | 35.01 | 0.83 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 66.30 | 36.74 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 31.81 | 42.66 | 0.00 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 16.96 | 69.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 105.03 | 42.61 | 7.67 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 16.96 | 22.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 205.95 | 73.18 | 4.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_12
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 20.38 | 73.18 | 0.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 42.50 | 70.34 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 90.04 | 48.72 | 4.83 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 130.79 | 33.70 | 0.33 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 174.56 | 27.87 | 1.67 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 205.95 | 26.66 | 0.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.95 | 22.16 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 164.84 | 26.72 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 115.25 | 35.01 | 0.83 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 66.30 | 36.74 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 31.81 | 42.66 | 0.00 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 16.96 | 69.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 105.03 | 42.61 | 7.67 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 16.96 | 22.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 205.95 | 73.18 | 4.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: FINESTORAGE_SKYLIGHT_11
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 20.38 | 73.18 | 0.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 42.50 | 70.34 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 90.04 | 48.72 | 4.83 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 130.79 | 33.70 | 0.33 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 174.56 | 27.87 | 1.67 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 205.95 | 26.66 | 0.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.95 | 22.16 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 164.84 | 26.72 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 115.25 | 35.01 | 0.83 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 66.30 | 36.74 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 31.81 | 42.66 | 0.00 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 16.96 | 69.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 105.03 | 42.61 | 7.67 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 16.96 | 22.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 205.95 | 73.18 | 4.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R8C1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R8C2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R8C4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R3C4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R3C2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R3C3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R3C1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R4C4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R4C3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R4C2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R4C1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R5C4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R5C1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R5C3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R5C2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R6C1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R6C2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R8C3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R6C4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R7C1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R7C2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R7C4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R6C3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R7C3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 35.82 | 10.70 | 25.12 | 27.14 | 54.40 | 3.00 | 0.00 | 0.00 |
February | 56.74 | 16.63 | 40.11 | 50.80 | 52.89 | 0.00 | 0.00 | 0.00 |
March | 88.47 | 45.88 | 42.59 | 99.49 | 35.31 | 31.67 | 0.00 | 0.00 |
April | 116.46 | 61.94 | 54.52 | 140.80 | 23.24 | 5.67 | 0.00 | 0.00 |
May | 149.21 | 91.98 | 57.23 | 182.84 | 21.57 | 5.50 | 0.00 | 0.00 |
June | 172.62 | 108.27 | 64.36 | 212.38 | 22.37 | 1.00 | 0.00 | 0.00 |
July | 160.55 | 97.68 | 62.86 | 196.16 | 23.62 | 0.00 | 0.00 | 0.00 |
August | 136.53 | 75.95 | 60.58 | 163.49 | 28.91 | 0.00 | 0.00 | 0.00 |
September | 101.00 | 54.81 | 46.19 | 118.12 | 32.55 | 1.50 | 0.00 | 0.00 |
October | 63.00 | 27.17 | 35.83 | 70.21 | 31.30 | 0.00 | 0.00 | 0.00 |
November | 36.26 | 11.12 | 25.14 | 38.15 | 29.05 | 12.83 | 0.00 | 0.00 |
December | 31.50 | 6.76 | 24.74 | 23.41 | 50.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 95.88 | 50.93 | 44.95 | 110.55 | 33.70 | 61.17 | 0.00 | 0.00 |
Minimum of Months | 31.50 | 6.76 | 24.74 | 23.41 | 21.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 172.62 | 108.27 | 64.36 | 212.38 | 54.40 | 31.67 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.130742E+09 | 30791227.44 | 99950573.86 | 44940597.00 | 0.397702E+09 |
February | 0.191344E+09 | 49382124.17 | 0.141962E+09 | 99628426.03 | 0.336461E+09 |
March | 0.333031E+09 | 0.143162E+09 | 0.189869E+09 | 0.305002E+09 | 0.244444E+09 |
April | 0.392051E+09 | 0.160463E+09 | 0.231589E+09 | 0.418621E+09 | 0.163397E+09 |
May | 0.478262E+09 | 0.215956E+09 | 0.262306E+09 | 0.561603E+09 | 0.127804E+09 |
June | 0.559175E+09 | 0.263071E+09 | 0.296104E+09 | 0.693904E+09 | 0.110044E+09 |
July | 0.515980E+09 | 0.225905E+09 | 0.290075E+09 | 0.671764E+09 | 90324636.11 |
August | 0.466166E+09 | 0.197703E+09 | 0.268463E+09 | 0.597673E+09 | 0.114046E+09 |
September | 0.355217E+09 | 0.153481E+09 | 0.201736E+09 | 0.415034E+09 | 0.152517E+09 |
October | 0.237853E+09 | 83784046.03 | 0.154068E+09 | 0.234388E+09 | 0.185513E+09 |
November | 0.135290E+09 | 38407002.71 | 96882587.32 | 99843120.83 | 0.220702E+09 |
December | 0.121956E+09 | 26424900.36 | 95530865.68 | 42799626.87 | 0.381234E+09 |
Annual Sum or Average | 0.391707E+10 | 0.158853E+10 | 0.232854E+10 | 0.418520E+10 | 0.252419E+10 |
Minimum of Months | 0.121956E+09 | 26424900.36 | 95530865.68 | 42799626.87 | 90324636.11 |
Maximum of Months | 0.559175E+09 | 0.263071E+09 | 0.296104E+09 | 0.693904E+09 | 0.397702E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.130742E+09 | 30791227.44 | 99950573.86 | 44940597.00 | 0.397702E+09 |
February | 0.191344E+09 | 49382124.17 | 0.141962E+09 | 99628426.03 | 0.336461E+09 |
March | 0.333031E+09 | 0.143162E+09 | 0.189869E+09 | 0.305002E+09 | 0.244444E+09 |
April | 0.392051E+09 | 0.160463E+09 | 0.231589E+09 | 0.418621E+09 | 0.163397E+09 |
May | 0.478262E+09 | 0.215956E+09 | 0.262306E+09 | 0.561603E+09 | 0.127804E+09 |
June | 0.559175E+09 | 0.263071E+09 | 0.296104E+09 | 0.693904E+09 | 0.110044E+09 |
July | 0.515980E+09 | 0.225905E+09 | 0.290075E+09 | 0.671764E+09 | 90324636.11 |
August | 0.466166E+09 | 0.197703E+09 | 0.268463E+09 | 0.597673E+09 | 0.114046E+09 |
September | 0.355217E+09 | 0.153481E+09 | 0.201736E+09 | 0.415034E+09 | 0.152517E+09 |
October | 0.237853E+09 | 83784046.03 | 0.154068E+09 | 0.234388E+09 | 0.185513E+09 |
November | 0.135290E+09 | 38407002.71 | 96882587.32 | 99843120.83 | 0.220702E+09 |
December | 0.121956E+09 | 26424900.36 | 95530865.68 | 42799626.87 | 0.381234E+09 |
Annual Sum or Average | 0.391707E+10 | 0.158853E+10 | 0.232854E+10 | 0.418520E+10 | 0.252419E+10 |
Minimum of Months | 0.121956E+09 | 26424900.36 | 95530865.68 | 42799626.87 | 90324636.11 |
Maximum of Months | 0.559175E+09 | 0.263071E+09 | 0.296104E+09 | 0.693904E+09 | 0.397702E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 48480816.47 | 0.00 | 48480816.47 | 1669834.64 | 0.247763E+09 |
February | 66718204.24 | 0.00 | 66718204.24 | 8148716.62 | 0.207771E+09 |
March | 89593725.91 | 3172.97 | 89590552.94 | 41433749.46 | 0.153284E+09 |
April | 0.110534E+09 | 532937.55 | 0.110001E+09 | 80287928.29 | 96472192.65 |
May | 0.132684E+09 | 5713234.58 | 0.126971E+09 | 0.121905E+09 | 71017661.83 |
June | 0.154379E+09 | 13126906.17 | 0.141252E+09 | 0.164719E+09 | 59988714.78 |
July | 0.148572E+09 | 10106717.66 | 0.138465E+09 | 0.177652E+09 | 49184675.69 |
August | 0.128629E+09 | 2483093.46 | 0.126146E+09 | 0.144973E+09 | 64376658.46 |
September | 94345004.11 | 41752.06 | 94303252.04 | 84495171.51 | 90646756.18 |
October | 72843239.37 | 0.00 | 72843239.37 | 45908812.40 | 0.111488E+09 |
November | 47369823.72 | 0.00 | 47369823.72 | 17158549.51 | 0.132509E+09 |
December | 45376574.77 | 0.00 | 45376574.77 | 1854999.26 | 0.234631E+09 |
Annual Sum or Average | 0.113953E+10 | 32007814.46 | 0.110752E+10 | 0.890207E+09 | 0.151913E+10 |
Minimum of Months | 45376574.77 | 0.00 | 45376574.77 | 1669834.64 | 49184675.69 |
Maximum of Months | 0.154379E+09 | 13126906.17 | 0.141252E+09 | 0.177652E+09 | 0.247763E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 48479158.37 | 0.00 | 48479158.37 | 1669464.65 | 0.247764E+09 |
February | 66715932.68 | 0.00 | 66715932.68 | 8147339.77 | 0.207772E+09 |
March | 89590934.60 | 3172.83 | 89587761.78 | 41431097.46 | 0.153284E+09 |
April | 0.110530E+09 | 532912.57 | 0.109998E+09 | 80284152.63 | 96472137.78 |
May | 0.132681E+09 | 5712966.79 | 0.126968E+09 | 0.121900E+09 | 71017319.99 |
June | 0.154375E+09 | 13126290.90 | 0.141248E+09 | 0.164713E+09 | 59988336.51 |
July | 0.148567E+09 | 10106243.94 | 0.138461E+09 | 0.177646E+09 | 49184259.12 |
August | 0.128625E+09 | 2482977.08 | 0.126142E+09 | 0.144968E+09 | 64376297.50 |
September | 94342149.51 | 41750.11 | 94300399.41 | 84491901.12 | 90646375.93 |
October | 72840871.72 | 0.00 | 72840871.72 | 45906286.71 | 0.111487E+09 |
November | 47368200.18 | 0.00 | 47368200.18 | 17157295.16 | 0.132509E+09 |
December | 45374986.93 | 0.00 | 45374986.93 | 1854633.77 | 0.234632E+09 |
Annual Sum or Average | 0.113949E+10 | 32006314.21 | 0.110748E+10 | 0.890169E+09 | 0.151913E+10 |
Minimum of Months | 45374986.93 | 0.00 | 45374986.93 | 1669464.65 | 49184259.12 |
Maximum of Months | 0.154375E+09 | 13126290.90 | 0.141248E+09 | 0.177646E+09 | 0.247764E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 54582609.35 | 0.196011E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.102806E+09 | 0.170175E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.241174E+09 | 0.130504E+09 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.339015E+09 | 87361292.73 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.467542E+09 | 74646264.13 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.533813E+09 | 69091385.22 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.527506E+09 | 59343907.21 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.441498E+09 | 71553972.11 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.298727E+09 | 90742082.97 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.177586E+09 | 98402182.64 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 82446957.14 | 0.110569E+09 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 45418916.59 | 0.185239E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.331211E+10 | 0.134364E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 45418916.59 | 59343907.21 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.533813E+09 | 0.196011E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_6
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 54582609.35 | 0.196011E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.102806E+09 | 0.170175E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.241174E+09 | 0.130504E+09 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.339015E+09 | 87361292.73 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.467542E+09 | 74646264.13 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.533813E+09 | 69091385.22 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.527506E+09 | 59343907.21 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.441498E+09 | 71553972.11 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.298727E+09 | 90742082.97 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.177586E+09 | 98402182.64 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 82446957.14 | 0.110569E+09 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 45418916.59 | 0.185239E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.331211E+10 | 0.134364E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 45418916.59 | 59343907.21 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.533813E+09 | 0.196011E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_7
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 54582609.35 | 0.196011E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.102806E+09 | 0.170175E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.241174E+09 | 0.130504E+09 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.339015E+09 | 87361292.73 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.467542E+09 | 74646264.13 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.533813E+09 | 69091385.22 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.527506E+09 | 59343907.21 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.441498E+09 | 71553972.11 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.298727E+09 | 90742082.97 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.177586E+09 | 98402182.64 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 82446957.14 | 0.110569E+09 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 45418916.59 | 0.185239E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.331211E+10 | 0.134364E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 45418916.59 | 59343907.21 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.533813E+09 | 0.196011E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_8
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 54582609.35 | 0.196011E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.102806E+09 | 0.170175E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.241174E+09 | 0.130504E+09 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.339015E+09 | 87361292.73 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.467542E+09 | 74646264.13 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.533813E+09 | 69091385.22 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.527506E+09 | 59343907.21 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.441498E+09 | 71553972.11 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.298727E+09 | 90742082.97 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.177586E+09 | 98402182.64 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 82446957.14 | 0.110569E+09 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 45418916.59 | 0.185239E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.331211E+10 | 0.134364E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 45418916.59 | 59343907.21 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.533813E+09 | 0.196011E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_9
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 54582609.35 | 0.196011E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.102806E+09 | 0.170175E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.241174E+09 | 0.130504E+09 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.339015E+09 | 87361292.73 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.467542E+09 | 74646264.13 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.533813E+09 | 69091385.22 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.527506E+09 | 59343907.21 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.441498E+09 | 71553972.11 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.298727E+09 | 90742082.97 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.177586E+09 | 98402182.64 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 82446957.14 | 0.110569E+09 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 45418916.59 | 0.185239E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.331211E+10 | 0.134364E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 45418916.59 | 59343907.21 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.533813E+09 | 0.196011E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_10
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 54582609.35 | 0.196011E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.102806E+09 | 0.170175E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.241174E+09 | 0.130504E+09 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.339015E+09 | 87361292.73 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.467542E+09 | 74646264.13 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.533813E+09 | 69091385.22 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.527506E+09 | 59343907.21 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.441498E+09 | 71553972.11 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.298727E+09 | 90742082.97 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.177586E+09 | 98402182.64 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 82446957.14 | 0.110569E+09 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 45418916.59 | 0.185239E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.331211E+10 | 0.134364E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 45418916.59 | 59343907.21 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.533813E+09 | 0.196011E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_5
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 54582609.35 | 0.196011E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.102806E+09 | 0.170175E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.241174E+09 | 0.130504E+09 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.339015E+09 | 87361292.73 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.467542E+09 | 74646264.13 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.533813E+09 | 69091385.22 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.527506E+09 | 59343907.21 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.441498E+09 | 71553972.11 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.298727E+09 | 90742082.97 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.177586E+09 | 98402182.64 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 82446957.14 | 0.110569E+09 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 45418916.59 | 0.185239E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.331211E+10 | 0.134364E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 45418916.59 | 59343907.21 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.533813E+09 | 0.196011E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 54582609.35 | 0.196011E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.102806E+09 | 0.170175E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.241174E+09 | 0.130504E+09 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.339015E+09 | 87361292.73 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.467542E+09 | 74646264.13 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.533813E+09 | 69091385.22 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.527506E+09 | 59343907.21 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.441498E+09 | 71553972.11 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.298727E+09 | 90742082.97 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.177586E+09 | 98402182.64 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 82446957.14 | 0.110569E+09 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 45418916.59 | 0.185239E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.331211E+10 | 0.134364E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 45418916.59 | 59343907.21 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.533813E+09 | 0.196011E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 54582609.35 | 0.196011E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.102806E+09 | 0.170175E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.241174E+09 | 0.130504E+09 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.339015E+09 | 87361292.73 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.467542E+09 | 74646264.13 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.533813E+09 | 69091385.22 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.527506E+09 | 59343907.21 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.441498E+09 | 71553972.11 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.298727E+09 | 90742082.97 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.177586E+09 | 98402182.64 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 82446957.14 | 0.110569E+09 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 45418916.59 | 0.185239E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.331211E+10 | 0.134364E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 45418916.59 | 59343907.21 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.533813E+09 | 0.196011E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 54582609.35 | 0.196011E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.102806E+09 | 0.170175E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.241174E+09 | 0.130504E+09 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.339015E+09 | 87361292.73 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.467542E+09 | 74646264.13 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.533813E+09 | 69091385.22 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.527506E+09 | 59343907.21 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.441498E+09 | 71553972.11 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.298727E+09 | 90742082.97 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.177586E+09 | 98402182.64 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 82446957.14 | 0.110569E+09 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 45418916.59 | 0.185239E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.331211E+10 | 0.134364E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 45418916.59 | 59343907.21 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.533813E+09 | 0.196011E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_14
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 54582609.35 | 0.196011E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.102806E+09 | 0.170175E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.241174E+09 | 0.130504E+09 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.339015E+09 | 87361292.73 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.467542E+09 | 74646264.13 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.533813E+09 | 69091385.22 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.527506E+09 | 59343907.21 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.441498E+09 | 71553972.11 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.298727E+09 | 90742082.97 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.177586E+09 | 98402182.64 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 82446957.14 | 0.110569E+09 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 45418916.59 | 0.185239E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.331211E+10 | 0.134364E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 45418916.59 | 59343907.21 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.533813E+09 | 0.196011E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_13
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 54582609.35 | 0.196011E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.102806E+09 | 0.170175E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.241174E+09 | 0.130504E+09 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.339015E+09 | 87361292.73 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.467542E+09 | 74646264.13 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.533813E+09 | 69091385.22 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.527506E+09 | 59343907.21 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.441498E+09 | 71553972.11 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.298727E+09 | 90742082.97 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.177586E+09 | 98402182.64 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 82446957.14 | 0.110569E+09 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 45418916.59 | 0.185239E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.331211E+10 | 0.134364E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 45418916.59 | 59343907.21 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.533813E+09 | 0.196011E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_12
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 54582609.35 | 0.196011E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.102806E+09 | 0.170175E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.241174E+09 | 0.130504E+09 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.339015E+09 | 87361292.73 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.467542E+09 | 74646264.13 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.533813E+09 | 69091385.22 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.527506E+09 | 59343907.21 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.441498E+09 | 71553972.11 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.298727E+09 | 90742082.97 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.177586E+09 | 98402182.64 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 82446957.14 | 0.110569E+09 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 45418916.59 | 0.185239E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.331211E+10 | 0.134364E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 45418916.59 | 59343907.21 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.533813E+09 | 0.196011E+09 |
Report: WindowEnergyReportMonthly
For: FINESTORAGE_SKYLIGHT_11
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 54582609.35 | 0.196011E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.102806E+09 | 0.170175E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.241174E+09 | 0.130504E+09 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.339015E+09 | 87361292.73 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.467542E+09 | 74646264.13 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.533813E+09 | 69091385.22 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.527506E+09 | 59343907.21 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.441498E+09 | 71553972.11 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.298727E+09 | 90742082.97 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.177586E+09 | 98402182.64 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 82446957.14 | 0.110569E+09 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 45418916.59 | 0.185239E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.331211E+10 | 0.134364E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 45418916.59 | 59343907.21 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.533813E+09 | 0.196011E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R8C1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R8C2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R8C4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R3C4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R3C2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R3C3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R3C1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R4C4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R4C3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R4C2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R4C1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R5C4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R5C1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R5C3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R5C2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R6C1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R6C2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R8C3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R6C4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R7C1
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R7C2
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R7C4
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R6C3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R7C3
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 95935596.03 | 28652938.24 | 67282657.79 | 72700694.71 | 0.145714E+09 |
February | 0.137257E+09 | 40220934.97 | 97035733.31 | 0.122894E+09 | 0.127963E+09 |
March | 0.236951E+09 | 0.122877E+09 | 0.114074E+09 | 0.266482E+09 | 94575204.53 |
April | 0.301872E+09 | 0.160559E+09 | 0.141313E+09 | 0.364960E+09 | 60234937.34 |
May | 0.399652E+09 | 0.246356E+09 | 0.153296E+09 | 0.489713E+09 | 57762282.17 |
June | 0.447436E+09 | 0.280626E+09 | 0.166810E+09 | 0.550495E+09 | 57979917.71 |
July | 0.430008E+09 | 0.261631E+09 | 0.168377E+09 | 0.525408E+09 | 63250782.59 |
August | 0.365673E+09 | 0.203413E+09 | 0.162260E+09 | 0.437895E+09 | 77430720.08 |
September | 0.261790E+09 | 0.142074E+09 | 0.119716E+09 | 0.306172E+09 | 84359987.93 |
October | 0.168744E+09 | 72776279.30 | 95967969.14 | 0.188059E+09 | 83826078.71 |
November | 93979969.59 | 28822863.05 | 65157106.54 | 98880428.20 | 75308125.71 |
December | 84359973.07 | 18103988.55 | 66255984.51 | 62688310.97 | 0.134249E+09 |
Annual Sum or Average | 0.302366E+10 | 0.160611E+10 | 0.141754E+10 | 0.348635E+10 | 0.106265E+10 |
Minimum of Months | 84359973.07 | 18103988.55 | 65157106.54 | 62688310.97 | 57762282.17 |
Maximum of Months | 0.447436E+09 | 0.280626E+09 | 0.168377E+09 | 0.550495E+09 | 0.145714E+09 |
Report: WindowZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 28.38 | 475.55 | 133.83 | 22.99 | 110.84 | 0.00 | 0.00 |
February | 82.03 | 442.86 | 213.34 | 40.83 | 172.52 | 0.00 | 0.00 |
March | 251.83 | 290.13 | 315.58 | 106.90 | 208.68 | 0.00 | 0.00 |
April | 383.38 | 198.94 | 387.80 | 124.23 | 263.57 | 0.00 | 0.00 |
May | 508.81 | 146.89 | 456.20 | 165.52 | 290.68 | 0.00 | 0.00 |
June | 659.32 | 128.01 | 550.58 | 213.12 | 337.46 | 0.00 | 0.00 |
July | 631.73 | 101.63 | 496.23 | 176.23 | 320.00 | 0.00 | 0.00 |
August | 553.73 | 132.42 | 444.14 | 149.48 | 294.66 | 0.00 | 0.00 |
September | 384.17 | 186.36 | 346.88 | 118.46 | 228.42 | 0.00 | 0.00 |
October | 207.63 | 220.11 | 232.00 | 62.56 | 169.44 | 0.00 | 0.00 |
November | 88.00 | 270.26 | 140.94 | 29.64 | 111.31 | 0.00 | 0.00 |
December | 27.51 | 454.04 | 124.95 | 19.73 | 105.22 | 0.00 | 0.00 |
Annual Sum or Average | 318.47 | 253.02 | 320.69 | 102.77 | 217.91 | 0.00 | 0.00 |
Minimum of Months | 27.51 | 101.63 | 124.95 | 19.73 | 105.22 | 0.00 | 0.00 |
Maximum of Months | 659.32 | 475.55 | 550.58 | 213.12 | 337.46 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 285.30 | 1024.55 | 501.46 | 149.77 | 351.69 | 0.00 | 0.00 |
February | 594.94 | 984.81 | 794.31 | 232.76 | 561.55 | 0.00 | 0.00 |
March | 1260.61 | 682.14 | 1238.54 | 642.28 | 596.26 | 0.00 | 0.00 |
April | 1831.10 | 471.86 | 1630.48 | 867.22 | 763.26 | 0.00 | 0.00 |
May | 2443.84 | 390.18 | 2088.98 | 1287.70 | 801.28 | 0.00 | 0.00 |
June | 2883.25 | 373.18 | 2416.71 | 1515.73 | 900.98 | 0.00 | 0.00 |
July | 2757.28 | 310.19 | 2247.65 | 1367.55 | 880.11 | 0.00 | 0.00 |
August | 2307.71 | 374.01 | 1911.37 | 1063.24 | 848.13 | 0.00 | 0.00 |
September | 1613.49 | 490.12 | 1413.99 | 767.37 | 646.61 | 0.00 | 0.00 |
October | 928.24 | 514.35 | 882.03 | 380.40 | 501.62 | 0.00 | 0.00 |
November | 445.32 | 597.21 | 507.61 | 155.68 | 351.93 | 0.00 | 0.00 |
December | 237.40 | 968.24 | 440.95 | 94.63 | 346.32 | 0.00 | 0.00 |
Annual Sum or Average | 1470.37 | 596.49 | 1342.31 | 713.01 | 629.30 | 0.00 | 0.00 |
Minimum of Months | 237.40 | 310.19 | 440.95 | 94.63 | 346.32 | 0.00 | 0.00 |
Maximum of Months | 2883.25 | 1024.55 | 2416.71 | 1515.73 | 900.98 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 4304.25 | 11889.94 | 1146.18 | 342.33 | 803.85 | 0.00 | 0.00 |
February | 8165.08 | 11952.95 | 1815.56 | 532.02 | 1283.54 | 0.00 | 0.00 |
March | 14256.40 | 6887.60 | 2830.96 | 1468.07 | 1362.89 | 0.00 | 0.00 |
April | 18346.13 | 3057.44 | 3726.81 | 1982.21 | 1744.60 | 0.00 | 0.00 |
May | 24699.61 | 2079.31 | 4774.82 | 2943.32 | 1831.49 | 0.00 | 0.00 |
June | 26756.46 | 2157.76 | 5523.90 | 3464.52 | 2059.38 | 0.00 | 0.00 |
July | 26389.70 | 2407.37 | 5137.50 | 3125.82 | 2011.67 | 0.00 | 0.00 |
August | 20741.33 | 2903.68 | 4368.85 | 2430.27 | 1938.59 | 0.00 | 0.00 |
September | 14371.27 | 3221.66 | 3231.97 | 1754.00 | 1477.97 | 0.00 | 0.00 |
October | 9122.03 | 3394.42 | 2016.06 | 869.49 | 1146.57 | 0.00 | 0.00 |
November | 4944.33 | 4735.83 | 1160.25 | 355.84 | 804.41 | 0.00 | 0.00 |
December | 3719.24 | 10825.47 | 1007.88 | 216.30 | 791.59 | 0.00 | 0.00 |
Annual Sum or Average | 14688.71 | 5429.82 | 3068.15 | 1629.75 | 1438.40 | 0.00 | 0.00 |
Minimum of Months | 3719.24 | 2079.31 | 1007.88 | 216.30 | 791.59 | 0.00 | 0.00 |
Maximum of Months | 26756.46 | 11952.95 | 5523.90 | 3464.52 | 2059.38 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 76005421.40 | 0.127372E+10 | 0.358444E+09 | 61582454.89 | 0.296861E+09 | 0.00 | 0.00 |
February | 0.198452E+09 | 0.107136E+10 | 0.516123E+09 | 98764248.34 | 0.417358E+09 | 0.00 | 0.00 |
March | 0.674502E+09 | 0.777090E+09 | 0.845247E+09 | 0.286331E+09 | 0.558916E+09 | 0.00 | 0.00 |
April | 0.993724E+09 | 0.515648E+09 | 0.100517E+10 | 0.321991E+09 | 0.683176E+09 | 0.00 | 0.00 |
May | 0.136281E+10 | 0.393441E+09 | 0.122189E+10 | 0.443338E+09 | 0.778550E+09 | 0.00 | 0.00 |
June | 0.170897E+10 | 0.331790E+09 | 0.142710E+10 | 0.552395E+09 | 0.874709E+09 | 0.00 | 0.00 |
July | 0.169201E+10 | 0.272205E+09 | 0.132910E+10 | 0.472023E+09 | 0.857076E+09 | 0.00 | 0.00 |
August | 0.148312E+10 | 0.354675E+09 | 0.118959E+10 | 0.400372E+09 | 0.789215E+09 | 0.00 | 0.00 |
September | 0.995781E+09 | 0.483053E+09 | 0.899122E+09 | 0.307046E+09 | 0.592076E+09 | 0.00 | 0.00 |
October | 0.556127E+09 | 0.589537E+09 | 0.621389E+09 | 0.167568E+09 | 0.453821E+09 | 0.00 | 0.00 |
November | 0.228096E+09 | 0.700518E+09 | 0.365317E+09 | 76814005.42 | 0.288503E+09 | 0.00 | 0.00 |
December | 73691299.39 | 0.121611E+10 | 0.334663E+09 | 52849800.71 | 0.281813E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.100433E+11 | 0.797915E+10 | 0.101132E+11 | 0.324108E+10 | 0.687207E+10 | 0.00 | 0.00 |
Minimum of Months | 73691299.39 | 0.272205E+09 | 0.334663E+09 | 52849800.71 | 0.281813E+09 | 0.00 | 0.00 |
Maximum of Months | 0.170897E+10 | 0.127372E+10 | 0.142710E+10 | 0.552395E+09 | 0.874709E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.764157E+09 | 0.274416E+10 | 0.134310E+10 | 0.401141E+09 | 0.941957E+09 | 0.00 | 0.00 |
February | 0.143928E+10 | 0.238245E+10 | 0.192159E+10 | 0.563093E+09 | 0.135850E+10 | 0.00 | 0.00 |
March | 0.337643E+10 | 0.182706E+10 | 0.331732E+10 | 0.172028E+10 | 0.159703E+10 | 0.00 | 0.00 |
April | 0.474621E+10 | 0.122306E+10 | 0.422621E+10 | 0.224783E+10 | 0.197838E+10 | 0.00 | 0.00 |
May | 0.654559E+10 | 0.104505E+10 | 0.559513E+10 | 0.344899E+10 | 0.214614E+10 | 0.00 | 0.00 |
June | 0.747339E+10 | 0.967279E+09 | 0.626410E+10 | 0.392877E+10 | 0.233533E+10 | 0.00 | 0.00 |
July | 0.738509E+10 | 0.830815E+09 | 0.602012E+10 | 0.366284E+10 | 0.235728E+10 | 0.00 | 0.00 |
August | 0.618097E+10 | 0.100176E+10 | 0.511942E+10 | 0.284779E+10 | 0.227164E+10 | 0.00 | 0.00 |
September | 0.418217E+10 | 0.127039E+10 | 0.366505E+10 | 0.198904E+10 | 0.167602E+10 | 0.00 | 0.00 |
October | 0.248621E+10 | 0.137763E+10 | 0.236242E+10 | 0.101887E+10 | 0.134355E+10 | 0.00 | 0.00 |
November | 0.115426E+10 | 0.154796E+10 | 0.131572E+10 | 0.403520E+09 | 0.912199E+09 | 0.00 | 0.00 |
December | 0.635865E+09 | 0.259335E+10 | 0.118104E+10 | 0.253456E+09 | 0.927584E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.463696E+11 | 0.188109E+11 | 0.423312E+11 | 0.224856E+11 | 0.198456E+11 | 0.00 | 0.00 |
Minimum of Months | 0.635865E+09 | 0.830815E+09 | 0.118104E+10 | 0.253456E+09 | 0.912199E+09 | 0.00 | 0.00 |
Maximum of Months | 0.747339E+10 | 0.274416E+10 | 0.626410E+10 | 0.392877E+10 | 0.235728E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.115285E+11 | 0.318460E+11 | 0.306994E+10 | 0.916894E+09 | 0.215305E+10 | 0.00 | 0.00 |
February | 0.197530E+11 | 0.289166E+11 | 0.439221E+10 | 0.128707E+10 | 0.310514E+10 | 0.00 | 0.00 |
March | 0.381844E+11 | 0.184478E+11 | 0.758244E+10 | 0.393207E+10 | 0.365036E+10 | 0.00 | 0.00 |
April | 0.475532E+11 | 0.792488E+10 | 0.965990E+10 | 0.513790E+10 | 0.452200E+10 | 0.00 | 0.00 |
May | 0.661554E+11 | 0.556923E+10 | 0.127889E+11 | 0.788340E+10 | 0.490547E+10 | 0.00 | 0.00 |
June | 0.693528E+11 | 0.559291E+10 | 0.143179E+11 | 0.898004E+10 | 0.533791E+10 | 0.00 | 0.00 |
July | 0.706822E+11 | 0.644791E+10 | 0.137603E+11 | 0.837220E+10 | 0.538807E+10 | 0.00 | 0.00 |
August | 0.555536E+11 | 0.777721E+10 | 0.117015E+11 | 0.650923E+10 | 0.519231E+10 | 0.00 | 0.00 |
September | 0.372503E+11 | 0.835053E+10 | 0.837727E+10 | 0.454637E+10 | 0.383090E+10 | 0.00 | 0.00 |
October | 0.244324E+11 | 0.909162E+10 | 0.539982E+10 | 0.232884E+10 | 0.307098E+10 | 0.00 | 0.00 |
November | 0.128157E+11 | 0.122753E+11 | 0.300736E+10 | 0.922332E+09 | 0.208503E+10 | 0.00 | 0.00 |
December | 0.996160E+10 | 0.289949E+11 | 0.269952E+10 | 0.579328E+09 | 0.212019E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.463223E+12 | 0.171235E+12 | 0.967571E+11 | 0.513957E+11 | 0.453614E+11 | 0.00 | 0.00 |
Minimum of Months | 0.996160E+10 | 0.556923E+10 | 0.269952E+10 | 0.579328E+09 | 0.208503E+10 | 0.00 | 0.00 |
Maximum of Months | 0.706822E+11 | 0.318460E+11 | 0.143179E+11 | 0.898004E+10 | 0.538807E+10 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | -3.4 | -4.9 | -8.7 | 5.96 | -14.4 | 41.15 | 62.17 | 0.00 |
February | -4.2 | -5.4 | -8.1 | 6.66 | -15.1 | 65.72 | 71.39 | 0.00 |
March | 2.67 | 0.66 | -2.8 | 5.20 | -8.9 | 69.76 | 141.76 | 0.00 |
April | 7.47 | 4.95 | 1.92 | 5.29 | -2.7 | 89.32 | 159.79 | 0.00 |
May | 13.73 | 9.66 | 5.81 | 4.79 | 3.34 | 93.75 | 203.34 | 0.03 |
June | 18.63 | 14.47 | 11.49 | 5.10 | 8.69 | 105.42 | 236.95 | 0.00 |
July | 22.03 | 18.19 | 16.11 | 4.43 | 13.39 | 102.98 | 214.28 | 0.00 |
August | 20.69 | 16.39 | 13.72 | 4.23 | 11.88 | 99.24 | 178.64 | 0.00 |
September | 16.55 | 13.42 | 11.22 | 4.10 | 7.08 | 75.66 | 154.97 | 0.03 |
October | 9.73 | 7.36 | 4.97 | 4.79 | 0.13 | 58.70 | 104.01 | 0.00 |
November | 6.03 | 3.70 | 0.77 | 5.87 | -3.2 | 41.19 | 58.47 | 0.00 |
December | -2.2 | -3.2 | -5.3 | 6.59 | -12.0 | 40.52 | 44.30 | 0.00 |
Annual Sum or Average | 9.05 | 6.33 | 3.49 | 5.24 | -0.9 | 73.64 | 136.19 | 0.01 |
Minimum of Months | -4.2 | -5.4 | -8.7 | 4.10 | -15.1 | 40.52 | 44.30 | 0.00 |
Maximum of Months | 22.03 | 18.19 | 16.11 | 6.66 | 13.39 | 105.42 | 236.95 | 0.03 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 11.70 | 11-JAN-15:00 | 10.14 | 8.90 | 13.40 | 7.15 | 65.50 | 1.00 |
February | 12.80 | 22-FEB-17:00 | 6.18 | -2.2 | 14.90 | 3.48 | 0.00 | 0.00 |
March | 26.10 | 15-MAR-13:00 | 16.06 | 9.40 | 6.70 | 14.65 | 249.50 | 400.00 |
April | 21.10 | 08-APR-12:00 | 13.43 | 7.80 | 8.20 | 11.46 | 330.00 | 283.50 |
May | 26.10 | 10-MAY-13:00 | 17.84 | 13.30 | 5.20 | 13.35 | 258.50 | 457.00 |
June | 30.60 | 12-JUN-13:00 | 20.23 | 15.00 | 8.20 | 17.93 | 252.00 | 572.00 |
July | 31.70 | 21-JUL-13:00 | 21.73 | 17.20 | 5.20 | 22.47 | 330.00 | 231.00 |
August | 30.60 | 10-AUG-13:00 | 20.24 | 15.00 | 5.70 | 19.70 | 220.50 | 635.00 |
September | 27.20 | 16-SEP-13:09 | 19.53 | 15.68 | 8.80 | 17.30 | 207.00 | 564.67 |
October | 22.20 | 11-OCT-12:00 | 14.14 | 8.30 | 6.20 | 6.95 | 121.00 | 665.00 |
November | 19.40 | 05-NOV-13:00 | 13.85 | 10.00 | 12.40 | 14.84 | 133.00 | 3.50 |
December | 15.00 | 01-DEC-10:00 | 12.41 | 10.60 | 12.90 | 10.69 | 56.50 | 11.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 11.70 | 6.18 | -2.2 | 5.20 | 3.48 | 0.00 | 0.00 | |
Maximum of Months | 31.70 | 21.73 | 17.20 | 14.90 | 22.47 | 330.00 | 665.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -13.9 | 31-JAN-01:00 | -14.5 | -17.2 | 1.50 | -25.9 | 0.00 | 0.00 |
February | -16.7 | 07-FEB-06:00 | -17.3 | -20.6 | 6.20 | -35.1 | 0.00 | 0.00 |
March | -13.3 | 07-MAR-05:19 | -13.9 | -16.7 | 2.43 | -32.2 | 0.00 | 0.00 |
April | -4.4 | 17-APR-05:00 | -5.4 | -7.8 | 2.10 | -20.5 | 35.00 | 151.50 |
May | 1.70 | 01-MAY-04:00 | 0.96 | 0.00 | 0.00 | -14.2 | 0.00 | 0.00 |
June | 6.70 | 04-JUN-04:00 | 5.40 | 3.90 | 2.10 | -7.3 | 20.00 | 104.00 |
July | 11.70 | 03-JUL-03:00 | 11.07 | 10.60 | 2.10 | -1.2 | 0.00 | 0.00 |
August | 11.10 | 01-AUG-04:00 | 10.75 | 10.60 | 2.10 | -0.8 | 0.00 | 0.00 |
September | 6.10 | 05-SEP-05:00 | 5.59 | 5.00 | 2.10 | -6.2 | 24.50 | 41.00 |
October | -2.8 | 17-OCT-04:10 | -3.2 | -4.0 | 2.18 | -19.4 | 0.00 | 0.00 |
November | -3.9 | 24-NOV-05:00 | -4.5 | -5.6 | 2.10 | -18.1 | 0.00 | 0.00 |
December | -18.9 | 11-DEC-05:00 | -19.4 | -23.3 | 2.10 | -35.1 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -18.9 | -19.4 | -23.3 | 0.00 | -35.1 | 0.00 | 0.00 | |
Maximum of Months | 11.70 | 11.07 | 10.60 | 6.20 | -0.8 | 35.00 | 151.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 10.21 | 11-JAN-17:00 | 11.10 | 9.40 | 10.30 | 6.55 | 0.00 | 0.00 |
February | 6.89 | 01-FEB-03:00 | 7.20 | 6.70 | 3.60 | 2.22 | 0.00 | 0.00 |
March | 17.83 | 14-MAR-12:00 | 25.00 | 13.90 | 6.20 | 14.10 | 197.00 | 562.50 |
April | 13.78 | 08-APR-13:00 | 20.60 | 8.90 | 10.30 | 9.72 | 268.50 | 325.50 |
May | 18.19 | 10-MAY-14:00 | 26.10 | 13.90 | 5.20 | 16.85 | 273.00 | 238.00 |
June | 23.75 | 27-JUN-12:00 | 30.60 | 21.10 | 9.30 | 21.09 | 304.00 | 606.00 |
July | 24.79 | 21-JUL-01:00 | 28.90 | 23.30 | 8.80 | 27.46 | 0.00 | 0.00 |
August | 23.42 | 13-AUG-15:00 | 29.40 | 21.10 | 9.80 | 19.87 | 212.00 | 276.00 |
September | 21.17 | 15-SEP-11:00 | 26.10 | 18.90 | 3.60 | 16.30 | 204.00 | 464.50 |
October | 15.23 | 12-OCT-14:00 | 18.30 | 13.30 | 10.30 | 9.13 | 148.00 | 367.50 |
November | 13.96 | 05-NOV-14:00 | 18.30 | 11.10 | 11.30 | 14.10 | 72.00 | 6.00 |
December | 12.41 | 01-DEC-10:00 | 15.00 | 10.60 | 12.90 | 10.69 | 56.50 | 11.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 6.89 | 7.20 | 6.70 | 3.60 | 2.22 | 0.00 | 0.00 | |
Maximum of Months | 24.79 | 30.60 | 23.30 | 12.90 | 27.46 | 304.00 | 606.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 9.40 | 11-JAN-13:00 | 10.00 | 9.66 | 12.90 | 5.54 | 95.50 | 2.00 |
February | 6.70 | 01-FEB-04:10 | 7.20 | 6.89 | 3.52 | 2.22 | 0.00 | 0.00 |
March | 15.00 | 14-MAR-10:20 | 20.33 | 16.97 | 4.80 | 10.50 | 159.17 | 592.83 |
April | 11.10 | 08-APR-21:00 | 13.90 | 12.23 | 12.90 | 9.72 | 0.00 | 0.00 |
May | 15.60 | 17-MAY-12:00 | 16.70 | 15.97 | 6.70 | 13.54 | 184.00 | 0.00 |
June | 21.70 | 27-JUN-14:00 | 25.60 | 22.78 | 8.20 | 16.85 | 255.50 | 530.00 |
July | 23.30 | 20-JUL-20:00 | 25.60 | 24.03 | 4.60 | 24.16 | 0.00 | 0.00 |
August | 21.70 | 14-AUG-03:20 | 23.70 | 22.19 | 5.00 | 21.90 | 0.00 | 0.00 |
September | 20.00 | 15-SEP-18:00 | 21.70 | 20.51 | 0.00 | 19.52 | 0.00 | 0.00 |
October | 14.40 | 01-OCT-07:19 | 14.60 | 14.50 | 3.77 | 10.56 | 67.50 | 30.17 |
November | 11.70 | 05-NOV-15:00 | 12.80 | 12.14 | 7.20 | 8.74 | 28.00 | 4.50 |
December | 11.10 | 01-DEC-12:00 | 13.90 | 12.22 | 10.30 | 6.35 | 158.00 | 84.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 6.70 | 7.20 | 6.89 | 0.00 | 2.22 | 0.00 | 0.00 | |
Maximum of Months | 23.30 | 25.60 | 24.03 | 12.90 | 24.16 | 255.50 | 592.83 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 7.32 | 12.49 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 6.57 | 19.26 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 7.29 | 28.63 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 9.34 | 37.44 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 12.19 | 46.60 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 15.07 | 54.01 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 17.20 | 50.29 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 18.01 | 43.20 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 17.27 | 32.93 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 15.18 | 21.28 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 12.32 | 12.54 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 9.45 | 10.96 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 12.30 | 30.86 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 6.57 | 10.96 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 18.01 | 54.01 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.994270E+09 | -922978636.1 | 0.00 | 0.00 | 744.00 | 0.00 | -71291284.7 | 58.99 | 0.00 | 0.00 |
February | 0.924432E+09 | -860102121.6 | 0.00 | 0.00 | 672.00 | 0.00 | -64329983.1 | 58.99 | 0.00 | 0.00 |
March | 0.106149E+10 | -991493811.8 | 0.00 | 0.00 | 744.00 | 0.00 | -69994746.4 | 58.99 | 0.00 | 0.00 |
April | 0.951418E+09 | -884834942.8 | 0.00 | 0.00 | 720.00 | 0.00 | -66582637.1 | 58.99 | 0.00 | 0.00 |
May | 0.931696E+09 | -868069853.5 | 0.00 | 0.00 | 744.00 | 0.00 | -63626569.5 | 58.99 | 0.00 | 0.00 |
June | 0.867924E+09 | -811338570.6 | 0.00 | 0.00 | 720.00 | 0.00 | -56585893.1 | 59.00 | 0.00 | 0.00 |
July | 0.802756E+09 | -745939125.8 | 0.00 | 0.00 | 744.00 | 0.00 | -56817237.8 | 59.00 | 0.00 | 0.00 |
August | 0.843342E+09 | -785999263.3 | 0.00 | 0.00 | 744.00 | 0.00 | -57342985.9 | 58.99 | 0.00 | 0.00 |
September | 0.801492E+09 | -744044027.2 | 0.00 | 0.00 | 720.00 | 0.00 | -57447660.3 | 59.00 | 0.00 | 0.00 |
October | 0.849716E+09 | -783064660.7 | 0.00 | 0.00 | 744.00 | 0.00 | -66650931.7 | 58.99 | 0.00 | 0.00 |
November | 0.868215E+09 | -800540065.1 | 0.00 | 0.00 | 720.00 | 0.00 | -67674868.4 | 58.99 | 0.00 | 0.00 |
December | 0.955113E+09 | -884012878.5 | 0.00 | 0.00 | 744.00 | 0.00 | -71100052.3 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.108519E+11 | -0.100824E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -769444850.3 | 58.99 | 0.00 | 0.00 |
Minimum of Months | 0.801492E+09 | -991493811.8 | 0.00 | 0.00 | 672.00 | 0.00 | -71291284.7 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.106149E+10 | -744044027.2 | 0.00 | 0.00 | 744.00 | 0.00 | -56585893.1 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: ZONE2 FINE STORAGE_DAYLCTRL
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 255.17 | 0.74 | 0.50 | 19-JAN-12:09 | 182.84 | 0.00 | 0.00 | 12.67 | 365.78 | 0.00 | 0.00 | 15.83 |
February | 262.50 | 0.67 | 0.50 | 02-FEB-10:00 | 256.05 | 0.00 | 0.00 | 97.83 | 336.55 | 0.00 | 0.00 | 49.00 |
March | 339.33 | 0.67 | 0.50 | 02-MAR-10:30 | 263.36 | 0.00 | 0.00 | 117.33 | 207.76 | 0.00 | 0.00 | 71.00 |
April | 371.17 | 0.66 | 0.50 | 01-APR-10:39 | 299.56 | 0.00 | 0.00 | 161.33 | 233.25 | 0.00 | 0.00 | 105.67 |
May | 332.17 | 0.65 | 0.50 | 01-MAY-09:00 | 319.92 | 0.00 | 0.00 | 191.00 | 894.98 | 0.00 | 0.00 | 133.50 |
June | 430.67 | 0.65 | 0.50 | 01-JUN-08:30 | 341.59 | 0.00 | 0.00 | 215.17 | 1719.54 | 0.00 | 0.00 | 170.17 |
July | 439.00 | 0.65 | 0.50 | 01-JUL-09:30 | 338.95 | 0.00 | 0.00 | 222.67 | 1230.07 | 0.00 | 0.00 | 172.67 |
August | 406.00 | 0.65 | 0.50 | 01-AUG-08:00 | 334.67 | 0.00 | 0.00 | 199.00 | 264.75 | 0.00 | 0.00 | 152.67 |
September | 289.17 | 0.66 | 0.50 | 01-SEP-09:20 | 287.37 | 0.00 | 0.00 | 141.33 | 692.30 | 0.00 | 0.00 | 99.50 |
October | 314.33 | 0.69 | 0.50 | 01-OCT-09:30 | 230.95 | 0.00 | 0.00 | 88.17 | 334.34 | 0.00 | 0.00 | 42.17 |
November | 258.33 | 0.75 | 0.50 | 01-NOV-11:09 | 181.29 | 0.00 | 0.00 | 17.83 | 141.25 | 0.00 | 0.00 | 0.33 |
December | 230.67 | 0.74 | 0.50 | 07-DEC-12:30 | 187.80 | 0.00 | 0.00 | 16.33 | 145.94 | 0.00 | 0.00 | 1.17 |
Annual Sum or Average | 3928.50 | 0.68 | 279.58 | 0.00 | 0.00 | 1480.67 | 610.80 | 0.00 | 0.00 | 1013.67 | ||
Minimum of Months | 230.67 | 0.65 | 0.50 | 181.29 | 0.00 | 0.00 | 12.67 | 141.25 | 0.00 | 0.00 | 0.33 | |
Maximum of Months | 439.00 | 0.75 | 0.50 | 341.59 | 0.00 | 0.00 | 222.67 | 1719.54 | 0.00 | 0.00 | 172.67 |
Report: DaylightingReportMonthly
For: ZONE3 BULK STORAGE_DAYLCTRL
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 255.17 | 0.62 | 0.50 | 01-JAN-10:30 | 209.78 | 13.21 | 0.00 | 123.50 | 174.03 | 16.43 | 2.83 | 89.17 |
February | 262.50 | 0.58 | 0.50 | 01-FEB-10:30 | 292.96 | 14.61 | 0.00 | 182.67 | 240.88 | 17.93 | 47.50 | 153.67 |
March | 339.33 | 0.58 | 0.50 | 01-MAR-09:00 | 299.38 | 14.27 | 0.00 | 231.83 | 248.74 | 17.85 | 70.67 | 190.83 |
April | 371.17 | 0.58 | 0.50 | 01-APR-07:49 | 339.71 | 14.49 | 0.00 | 266.50 | 283.35 | 18.08 | 100.83 | 228.83 |
May | 332.17 | 0.58 | 0.50 | 01-MAY-07:40 | 1122.56 | 14.58 | 2.00 | 299.67 | 2012.12 | 19.71 | 107.00 | 260.50 |
June | 430.67 | 0.57 | 0.50 | 01-JUN-06:30 | 2195.07 | 14.74 | 4.33 | 319.17 | 2375.21 | 18.49 | 121.00 | 273.83 |
July | 439.00 | 0.58 | 0.50 | 01-JUL-07:10 | 1612.62 | 14.75 | 4.00 | 319.17 | 1967.21 | 19.04 | 122.67 | 281.33 |
August | 406.00 | 0.57 | 0.50 | 01-AUG-06:49 | 382.50 | 15.05 | 3.17 | 298.50 | 694.37 | 19.32 | 131.17 | 260.00 |
September | 289.17 | 0.58 | 0.50 | 01-SEP-07:00 | 710.42 | 16.18 | 17.67 | 242.50 | 1027.80 | 18.65 | 94.33 | 202.67 |
October | 314.33 | 0.60 | 0.50 | 01-OCT-08:09 | 639.49 | 14.64 | 12.83 | 202.67 | 521.33 | 17.29 | 45.00 | 161.17 |
November | 258.33 | 0.62 | 0.50 | 01-NOV-08:00 | 791.90 | 12.77 | 0.00 | 131.50 | 504.27 | 15.92 | 3.00 | 93.00 |
December | 230.67 | 0.61 | 0.50 | 01-DEC-11:00 | 515.99 | 13.24 | 0.00 | 124.33 | 456.69 | 16.41 | 1.67 | 87.67 |
Annual Sum or Average | 3928.50 | 0.59 | 832.28 | 14.47 | 44.00 | 2742.00 | 975.11 | 18.10 | 847.67 | 2282.67 | ||
Minimum of Months | 230.67 | 0.57 | 0.50 | 209.78 | 12.77 | 0.00 | 123.50 | 174.03 | 15.92 | 1.67 | 87.67 | |
Maximum of Months | 439.00 | 0.62 | 0.50 | 2195.07 | 16.18 | 17.67 | 319.17 | 2375.21 | 19.71 | 131.17 | 281.33 |
Report: DaylightingReportMonthly
For: ZONE1 OFFICE_DAYLCTRL
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 255.17 | 0.83 | 0.64 | 30-JAN-14:30 | 212.18 | 22.34 | 117.17 | 13.67 | 96.68 | 20.23 | 92.00 | 0.00 |
February | 262.50 | 0.78 | 0.61 | 06-FEB-15:20 | 293.94 | 23.41 | 165.17 | 44.33 | 139.42 | 21.50 | 153.50 | 0.67 |
March | 339.33 | 0.76 | 0.61 | 01-MAR-15:20 | 411.55 | 23.39 | 188.67 | 76.17 | 319.62 | 23.92 | 206.50 | 38.17 |
April | 371.17 | 0.76 | 0.61 | 02-APR-14:20 | 326.41 | 21.70 | 189.67 | 95.83 | 285.26 | 22.75 | 227.00 | 62.83 |
May | 332.17 | 0.72 | 0.61 | 01-MAY-14:39 | 319.56 | 21.60 | 202.00 | 102.83 | 389.84 | 22.76 | 252.83 | 76.67 |
June | 430.67 | 0.72 | 0.61 | 01-JUN-14:39 | 332.24 | 21.51 | 228.67 | 144.50 | 438.33 | 22.79 | 281.17 | 105.17 |
July | 439.00 | 0.73 | 0.61 | 01-JUL-14:09 | 319.60 | 21.42 | 231.33 | 139.00 | 396.88 | 22.62 | 289.33 | 94.50 |
August | 406.00 | 0.73 | 0.61 | 01-AUG-13:50 | 316.48 | 21.76 | 223.00 | 124.33 | 320.89 | 22.74 | 268.00 | 81.17 |
September | 289.17 | 0.73 | 0.61 | 01-SEP-14:09 | 514.28 | 24.21 | 189.83 | 92.50 | 441.90 | 24.73 | 226.50 | 56.33 |
October | 314.33 | 0.78 | 0.61 | 01-OCT-16:19 | 358.00 | 23.54 | 166.33 | 53.00 | 156.34 | 22.61 | 169.83 | 11.67 |
November | 258.33 | 0.84 | 0.63 | 03-NOV-15:20 | 204.18 | 21.46 | 104.67 | 12.33 | 96.51 | 19.80 | 87.83 | 0.00 |
December | 230.67 | 0.83 | 0.65 | 10-DEC-14:20 | 194.30 | 21.75 | 101.67 | 8.17 | 98.60 | 20.35 | 88.33 | 0.00 |
Annual Sum or Average | 3928.50 | 0.76 | 323.01 | 22.27 | 2108.17 | 906.67 | 285.85 | 22.39 | 2342.83 | 527.17 | ||
Minimum of Months | 230.67 | 0.72 | 0.61 | 194.30 | 21.42 | 101.67 | 8.17 | 96.51 | 19.80 | 87.83 | 0.00 | |
Maximum of Months | 439.00 | 0.84 | 0.65 | 514.28 | 24.21 | 231.33 | 144.50 | 441.90 | 24.73 | 289.33 | 105.17 |
Report: CoilReportMonthly
For: PSZ-OFFICE HEATING COIL
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.920715E+10 | 25733.53 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.844260E+10 | 25733.53 | 01-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.579448E+10 | 25733.53 | 01-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.254798E+10 | 25733.53 | 01-APR-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.263784E+09 | 25733.53 | 01-MAY-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 534975.31 | 1783.25 | 29-SEP-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.117013E+10 | 25733.53 | 10-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.369209E+10 | 25733.53 | 01-NOV-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.800985E+10 | 25733.53 | 01-DEC-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.391286E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.920715E+10 | 25733.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE HEATING COIL
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.290811E+11 | 74279.25 | 03-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.268623E+11 | 74279.25 | 03-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.126782E+11 | 74279.25 | 04-MAR-05:23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.277778E+10 | 50930.78 | 17-APR-02:53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 154441.98 | 1544.42 | 01-MAY-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.435506E+09 | 37288.89 | 31-OCT-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.678374E+10 | 67340.71 | 24-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.261572E+11 | 74279.25 | 06-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.104776E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.290811E+11 | 74279.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ZONE3UNITHEATER ZONE3HIRADIANT HEATING COIL
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.113414E+12 | 132540.27 | 12-JAN-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.119488E+12 | 132540.27 | 06-FEB-09:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.417468E+11 | 76588.97 | 05-MAR-01:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.574305E+10 | 52790.54 | 16-APR-06:53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.957333E+10 | 27409.75 | 25-NOV-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.107744E+12 | 125238.74 | 09-DEC-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.397709E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.119488E+12 | 132540.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 12456550.29 | 11650571.64 | 1318.76 | 15-MAR-14:40 | 1236.03 | 0.00 |
April | 0.00 | 0.00 | 26.58 | 26.58 | 0.04 | 22-APR-16:00 | 0.04 | 0.00 |
May | 0.00 | 0.00 | 0.242371E+09 | 0.232758E+09 | 4224.13 | 23-MAY-14:50 | 4224.13 | 0.00 |
June | 0.00 | 0.00 | 0.328793E+10 | 0.257676E+10 | 20995.53 | 27-JUN-07:02 | 10602.75 | 0.00 |
July | 0.00 | 0.00 | 0.742570E+10 | 0.537744E+10 | 21511.23 | 21-JUL-06:02 | 11395.64 | 0.00 |
August | 0.00 | 0.00 | 0.606366E+10 | 0.491557E+10 | 21383.55 | 14-AUG-07:03 | 9889.25 | 0.00 |
September | 0.00 | 0.00 | 0.187066E+10 | 0.144658E+10 | 19899.46 | 14-SEP-07:02 | 10215.07 | 0.00 |
October | 0.00 | 0.00 | 8413501.96 | 8287198.89 | 1100.42 | 11-OCT-15:00 | 1084.19 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.189112E+11 | 0.145691E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.742570E+10 | 0.537744E+10 | 21511.23 | 11395.64 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.387273E+10 | 0.272732E+10 | 57407.57 | 27-JUN-17:13 | 30515.21 | 0.00 |
July | 0.00 | 0.00 | 0.130890E+11 | 0.892103E+10 | 58982.28 | 20-JUL-23:05 | 27148.12 | 0.00 |
August | 0.00 | 0.00 | 0.868815E+10 | 0.680889E+10 | 55705.65 | 13-AUG-18:25 | 31871.80 | 0.00 |
September | 0.00 | 0.00 | 0.405871E+09 | 0.292335E+09 | 11584.38 | 16-SEP-13:40 | 8222.91 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.260558E+11 | 0.187496E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.130890E+11 | 0.892103E+10 | 58982.28 | 31871.80 | 0.00 |
Report: FanReportMonthly
For: ZONE3UNITHEATER ZONE3HIRADIANT FAN
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.799815E+09 | 0.08 | 308.61 | 01-JAN-00:03 | 0.08 |
February | 0.730471E+09 | 0.08 | 308.61 | 01-FEB-00:03 | 0.08 |
March | 0.472199E+09 | 0.04 | 308.61 | 01-MAR-00:03 | 0.08 |
April | 0.117394E+09 | 0.01 | 308.61 | 01-APR-00:20 | 0.08 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 |
November | 0.268472E+09 | 0.03 | 308.61 | 11-NOV-04:40 | 0.08 |
December | 0.792409E+09 | 0.08 | 308.61 | 01-DEC-00:05 | 0.08 |
Annual Sum or Average | 0.318076E+10 | 0.03 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.799815E+09 | 0.08 | 308.61 | 0.08 |
Report: FanReportMonthly
For: PSZ-OFFICE_ADDAQ SUPPLY FAN
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.109373E+10 | 0.51 | 1051.40 | 04-JAN-08:07 | 0.94 |
February | 0.100787E+10 | 0.52 | 1051.40 | 01-FEB-07:30 | 0.93 |
March | 0.114870E+10 | 0.43 | 1051.40 | 01-MAR-14:50 | 0.93 |
April | 0.104795E+10 | 0.37 | 1051.40 | 01-APR-07:50 | 0.93 |
May | 0.108273E+10 | 0.36 | 1051.40 | 01-MAY-06:40 | 0.93 |
June | 0.108252E+10 | 0.37 | 1051.40 | 02-JUN-07:20 | 0.92 |
July | 0.104088E+10 | 0.34 | 1051.40 | 01-JUL-07:00 | 0.92 |
August | 0.112415E+10 | 0.37 | 1051.40 | 01-AUG-08:20 | 0.92 |
September | 0.104088E+10 | 0.35 | 1051.40 | 01-SEP-11:40 | 0.92 |
October | 0.104223E+10 | 0.35 | 1051.40 | 06-OCT-06:40 | 0.93 |
November | 0.100751E+10 | 0.36 | 1051.40 | 01-NOV-07:00 | 0.93 |
December | 0.108042E+10 | 0.47 | 1051.40 | 01-DEC-07:20 | 0.93 |
Annual Sum or Average | 0.127996E+11 | 0.40 | |||
Minimum of Months | 0.100751E+10 | 0.34 | 1051.40 | 0.92 | |
Maximum of Months | 0.114870E+10 | 0.52 | 1051.40 | 0.94 |
Report: FanReportMonthly
For: PSZ-FINE STORAGE_ADDAQ SUPPLY FAN
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.156026E+10 | 0.59 | 2164.29 | 03-JAN-06:01 | 0.90 |
February | 0.144349E+10 | 0.60 | 2164.29 | 03-FEB-06:01 | 0.90 |
March | 0.124556E+10 | 0.46 | 2164.29 | 04-MAR-05:23 | 0.90 |
April | 0.931002E+09 | 0.30 | 1547.83 | 11-APR-06:01 | 0.77 |
May | 0.891345E+09 | 0.21 | 892.72 | 01-MAY-06:02 | 0.55 |
June | 0.913290E+09 | 0.22 | 2164.29 | 27-JUN-17:13 | 0.88 |
July | 0.961807E+09 | 0.24 | 2164.29 | 16-JUL-15:53 | 0.89 |
August | 0.982187E+09 | 0.24 | 1800.33 | 10-AUG-17:10 | 0.82 |
September | 0.857060E+09 | 0.21 | 865.72 | 15-SEP-14:20 | 0.54 |
October | 0.868290E+09 | 0.21 | 1517.62 | 31-OCT-06:01 | 0.76 |
November | 0.998596E+09 | 0.41 | 2042.99 | 24-NOV-07:01 | 0.88 |
December | 0.149272E+10 | 0.59 | 2164.29 | 06-DEC-06:01 | 0.90 |
Annual Sum or Average | 0.131456E+11 | 0.35 | |||
Minimum of Months | 0.857060E+09 | 0.21 | 865.72 | 0.54 | |
Maximum of Months | 0.156026E+10 | 0.60 | 2164.29 | 0.90 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-OFFICE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.109373E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.100787E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.115151E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.104795E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.113450E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.174531E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.251433E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.234156E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.142130E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.104409E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.100751E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.108042E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.165901E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.100751E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.251433E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.156026E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.144349E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.124556E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.931002E+09 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.891345E+09 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.183758E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.405225E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.309035E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.959778E+09 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.868290E+09 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.998596E+09 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.149272E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.193712E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.868290E+09 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.405225E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-OFFICE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.109373E+10 | 0.00 | 0.920715E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.100787E+10 | 0.00 | 0.844260E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.114870E+10 | 12456550.29 | 0.579448E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.104795E+10 | 26.58 | 0.254798E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.108273E+10 | 0.242371E+09 | 0.263784E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.108252E+10 | 0.328793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.104088E+10 | 0.742570E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.112415E+10 | 0.606366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.104088E+10 | 0.187066E+10 | 534975.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.104223E+10 | 8413501.96 | 0.117013E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.100751E+10 | 0.00 | 0.369209E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.108042E+10 | 0.00 | 0.800985E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.127996E+11 | 0.189112E+11 | 0.391286E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.100751E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.114870E+10 | 0.742570E+10 | 0.920715E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-FINE STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.156026E+10 | 0.00 | 0.290811E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.144349E+10 | 0.00 | 0.268623E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.124556E+10 | 0.00 | 0.126782E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.931002E+09 | 0.00 | 0.277778E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.891345E+09 | 0.00 | 154441.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.913290E+09 | 0.359587E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.961807E+09 | 0.122598E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.982187E+09 | 0.830055E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.857060E+09 | 0.405871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.868290E+09 | 0.00 | 0.435506E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.998596E+09 | 0.00 | 0.678374E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.149272E+10 | 0.00 | 0.261572E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.131456E+11 | 0.245621E+11 | 0.104776E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.857060E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.156026E+10 | 0.122598E+11 | 0.290811E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-OFFICE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.109373E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.100787E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.114870E+10 | 0.00 | 0.00 | 0.00 | 2802222.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.104795E+10 | 0.00 | 0.00 | 0.00 | 5.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.108273E+10 | 0.00 | 0.00 | 0.00 | 51771162.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.108252E+10 | 0.00 | 0.00 | 0.00 | 0.662791E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.104088E+10 | 0.00 | 0.00 | 0.00 | 0.147344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.112415E+10 | 0.00 | 0.00 | 0.00 | 0.121741E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.104088E+10 | 0.00 | 0.00 | 0.00 | 0.380417E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.104223E+10 | 0.00 | 0.00 | 0.00 | 1855413.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.100751E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.108042E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.127996E+11 | 0.00 | 0.00 | 0.00 | 0.379049E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.100751E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.114870E+10 | 0.00 | 0.00 | 0.00 | 0.147344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.156026E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.144349E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.124556E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.931002E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.891345E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.913290E+09 | 0.00 | 0.00 | 0.00 | 0.924289E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.961807E+09 | 0.00 | 0.00 | 0.00 | 0.309044E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.982187E+09 | 0.00 | 0.00 | 0.00 | 0.210817E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.857060E+09 | 0.00 | 0.00 | 0.00 | 0.102717E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.868290E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.998596E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.149272E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.131456E+11 | 0.00 | 0.00 | 0.00 | 0.622562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.857060E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.156026E+10 | 0.00 | 0.00 | 0.00 | 0.309044E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE1 OFFICE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 19304757.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.272520E+10 | 0.00 | 0.00 | 0.12 |
February | 20324822.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.256447E+10 | 0.00 | 0.00 | 0.12 |
March | 0.124713E+09 | 0.00 | 50359.87 | 0.00 | 417452.93 | 0.202353E+10 | 0.00 | 791.10 | 0.13 |
April | 0.366453E+09 | 0.00 | 0.00 | 11.15 | 0.00 | 0.112847E+10 | 1078058.40 | 0.00 | 0.12 |
May | 0.614797E+09 | 1834325.91 | 0.00 | 1021102.04 | 0.00 | 85174041.17 | 0.105507E+10 | 0.00 | 0.28 |
June | 52230384.61 | 0.257060E+09 | 0.00 | 4115433.64 | 2752468.16 | 0.00 | 0.225206E+10 | 0.00 | 0.56 |
July | 6126895.11 | 0.915851E+09 | 0.00 | 3190837.11 | 4048337.10 | 0.00 | 0.591284E+09 | 0.00 | 0.48 |
August | 15701885.10 | 0.449529E+09 | 0.00 | 5372992.85 | 1940808.23 | 0.00 | 0.137695E+10 | 0.00 | 0.55 |
September | 0.101311E+09 | 0.107527E+09 | 0.00 | 3601700.75 | 955766.34 | 418176.63 | 0.227790E+10 | 0.00 | 0.56 |
October | 0.737349E+09 | 0.00 | 0.00 | 163156.05 | 0.00 | 0.534169E+09 | 0.248957E+09 | 0.00 | 0.15 |
November | 65502167.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.155981E+10 | 0.00 | 12793.66 | 0.12 |
December | 23427099.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.258171E+10 | 0.00 | 0.00 | 0.12 |
Annual Sum or Average | 0.214724E+10 | 0.173180E+10 | 50359.87 | 17465233.59 | 10114832.76 | 0.132029E+11 | 0.780330E+10 | 13584.76 | 0.28 |
Minimum of Months | 6126895.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.12 |
Maximum of Months | 0.737349E+09 | 0.915851E+09 | 50359.87 | 5372992.85 | 4048337.10 | 0.272520E+10 | 0.227790E+10 | 12793.66 | 0.56 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.703391E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.817385E+10 | 0.00 | 0.00 | 0.17 |
February | 0.152318E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.684356E+10 | 0.00 | 0.00 | 0.17 |
March | 0.461542E+10 | 0.00 | 0.00 | 0.00 | 48225192.07 | 0.178002E+10 | 0.00 | 0.00 | 0.19 |
April | 0.399301E+10 | 0.00 | 0.00 | 0.00 | 2046495.88 | 0.190391E+09 | 0.00 | 0.00 | 0.18 |
May | 0.386976E+10 | 0.00 | 0.00 | 0.00 | 2566322.89 | 0.00 | 0.00 | 0.00 | 0.18 |
June | 0.263617E+10 | 0.350655E+09 | 0.00 | 3410316.82 | 7896879.79 | 0.00 | 0.176173E+10 | 0.00 | 0.27 |
July | 0.209964E+09 | 0.147779E+10 | 0.00 | 6796553.88 | 880463.17 | 0.00 | 0.225659E+10 | 0.00 | 0.35 |
August | 0.103758E+10 | 0.446935E+09 | 0.00 | 8743634.47 | 0.00 | 0.00 | 0.253376E+10 | 0.00 | 0.32 |
September | 0.361789E+10 | 13837551.79 | 0.00 | 651779.57 | 0.00 | 0.00 | 0.580482E+09 | 0.00 | 0.21 |
October | 0.407111E+10 | 0.00 | 0.00 | 0.00 | 2401277.23 | 35304770.29 | 0.00 | 0.00 | 0.17 |
November | 0.374215E+10 | 0.00 | 0.00 | 0.00 | 23902581.20 | 0.697762E+09 | 0.00 | 0.00 | 0.17 |
December | 0.127168E+10 | 0.00 | 0.00 | 0.00 | 3458219.73 | 0.693962E+10 | 0.00 | 0.00 | 0.17 |
Annual Sum or Average | 0.312913E+11 | 0.228921E+10 | 0.00 | 19602284.73 | 91377431.96 | 0.246605E+11 | 0.713256E+10 | 0.00 | 0.21 |
Minimum of Months | 0.209964E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 |
Maximum of Months | 0.461542E+10 | 0.147779E+10 | 0.00 | 8743634.47 | 48225192.07 | 0.817385E+10 | 0.253376E+10 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 10:44:03
Custom Monthly ReportSITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
January | 0.221754E+12 | 0.103766E+12 | 0.00 | 0.116217E+11 | 0.431691E+11 |
February | 0.407862E+12 | 0.113063E+12 | 0.00 | 0.109515E+11 | 0.431790E+11 |
March | 0.692085E+12 | 0.565841E+11 | 0.00 | 0.849498E+10 | 0.180852E+11 |
April | 0.859663E+12 | 0.318181E+11 | 0.00 | 0.567735E+10 | 0.386144E+10 |
May | 0.110166E+13 | 0.235066E+11 | 0.00 | 0.562142E+10 | 0.417965E+09 |
June | 0.122789E+13 | 0.282807E+11 | 0.00 | 0.608714E+10 | 0.874774E+10 |
July | 0.116324E+13 | 0.284091E+11 | 0.00 | 0.645329E+09 | 0.250786E+11 |
August | 0.986510E+12 | 0.341312E+11 | 0.00 | 0.406596E+10 | 0.180774E+11 |
September | 0.720757E+12 | 0.314250E+11 | 0.00 | 0.645993E+10 | 0.275995E+10 |
October | 0.447168E+12 | 0.343207E+11 | 0.00 | 0.562466E+10 | 0.780385E+09 |
November | 0.191644E+12 | 0.348788E+11 | 0.00 | 0.604131E+10 | 0.723603E+10 |
December | 0.186173E+12 | 0.104767E+12 | 0.00 | 0.108130E+11 | 0.402149E+11 |
Annual Sum or Average | 0.820641E+13 | 0.624950E+12 | 0.00 | 0.821043E+11 | 0.211608E+12 |
Minimum of Months | 0.186173E+12 | 0.235066E+11 | 0.00 | 0.645329E+09 | 0.417965E+09 |
Maximum of Months | 0.122789E+13 | 0.113063E+12 | 0.00 | 0.116217E+11 | 0.431790E+11 |