Table of Contents

Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2024.07.03 12:27

Tabular Output Report in Format: HTML

Building: ApartmentMidRise

Environment: RUNPERIOD 1 ** Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745

Simulation Timestamp: 2024-07-03 12:27:39


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 1155.24 368.54 409.08
Net Site Energy 1072.54 342.16 379.80
Total Source Energy 2994.13 955.18 1060.25
Net Source Energy 2732.24 871.64 967.52


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 1.200
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil No 1 1.050
Fuel Oil No 2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 3134.61
Net Conditioned Building Area 2823.98
Unconditioned Building Area 310.64


End Uses

Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 1.82 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 213.58 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 53.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 22.83 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 423.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 120.13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 319.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1672.95
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total End Uses 836.23 319.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1672.95
Note: Electricity appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating General 1.82 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 213.58 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting LightsWired 49.34 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  LightsPlugIn 4.52 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 22.83 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment ElevatorLift 37.08 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ElevatorLightsFan 0.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  MiscPlug 386.12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  General 120.13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps General 0.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1672.95
  Water Heater 0.00 319.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators DCtoACInverter Ancillary 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


End Uses By Space Type

Space Type Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Unassigned 1.82 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling Unassigned 213.58 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting GENERAL 53.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting Unassigned 22.83 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment GENERAL 423.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans Unassigned 120.13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps Unassigned 0.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Unassigned 0.00 319.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1672.95
Refrigeration Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Gasoline Intensity [MJ/m2] Diesel Intensity [MJ/m2] Coal Intensity [MJ/m2] Fuel Oil No 1 Intensity [MJ/m2] Fuel Oil No 2 Intensity [MJ/m2] Propane Intensity [MJ/m2] Other Fuel 1 Intensity [MJ/m2] Other Fuel 2 Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 27.16 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
HVAC 118.96 112.97 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.59
Other 150.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total 296.12 112.97 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.59


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Gasoline Intensity [MJ/m2] Diesel Intensity [MJ/m2] Coal Intensity [MJ/m2] Fuel Oil No 1 Intensity [MJ/m2] Fuel Oil No 2 Intensity [MJ/m2] Propane Intensity [MJ/m2] Other Fuel 1 Intensity [MJ/m2] Other Fuel 2 Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 24.47 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
HVAC 107.17 101.77 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.53
Other 135.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total 266.77 101.77 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.53


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.000 0.00
High Temperature Geothermal* 0.000 0.00
Photovoltaic Power 86.260 10.32
Wind Power 0.000 0.00
Power Conversion -3.57 -0.4
Net Decrease in On-Site Storage 0.000 0.00
Total On-Site Electric Sources 82.693 9.89
     
Electricity Coming From Utility 753.532 90.11
Surplus Electricity Going To Utility 0.000 0.00
Net Electricity From Utility 753.532 90.11
     
Total On-Site and Utility Electric Sources 836.225 100.00
Total Electricity End Uses 836.225 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00 0.00
Air to Air Heat Recovery for Cooling 47.46 32.05
Air to Air Heat Recovery for Heating 100.60 67.95
High-Temperature Geothermal* 0.00 0.00
Solar Water Thermal 0.00 0.00
Solar Air Thermal 0.00 0.00
Total On-Site Thermal Sources 148.06 100.00


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 1672.95 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 1672.95 100.00
Total Water End Uses 1672.95 100.00


Setpoint Not Met Criteria

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.56
Tolerance for Zone Cooling Setpoint Not Met Time 0.56


Comfort and Setpoint Not Met Summary

Facility [Hours]
Time Setpoint Not Met During Occupied Heating 0.00
Time Setpoint Not Met During Occupied Cooling 0.00
Time Not Comfortable Based on Simple ASHRAE 55-2004 8760.00


Note 1: An asterisk (*) indicates that the feature is not yet implemented.

Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Adaptive Comfort Summary
Initialization Summary
Annual Heat Emissions Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
Coil Sizing Details
System Summary
Outdoor Air Summary
Outdoor Air Details
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary
Annual Thermal Resilience Summary
Annual CO2 Resilience Summary
Annual Visual Resilience Summary

NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 2B

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2022

| Environment |

NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE

| Environment |

NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_AZ_TUCSON

| Environment |

NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL

| Environment |

NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PERFORMANCEPATHPROPOSED

| Environment |

NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL

| Environment |

ZoneCoolingSummaryMonthly

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

ZoneHeatingSummaryMonthly

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

ZoneElectricSummaryMonthly

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

SpaceGainsMonthly

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

PeakSpaceGainsMonthly

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

SpaceGainComponentsAtCoolingPeakMonthly

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

EnergyConsumptionElectricityNaturalGasMonthly

| Meter |

EnergyConsumptionElectricityGeneratedPropaneMonthly

| Meter |

EndUseEnergyConsumptionElectricityMonthly

| Meter |

EndUseEnergyConsumptionNaturalGasMonthly

| Meter |

PeakEnergyEndUseElectricityPart1Monthly

| Meter |

PeakEnergyEndUseElectricityPart2Monthly

| Meter |

ElectricComponentsOfPeakDemandMonthly

| Meter |

PeakEnergyEndUseNaturalGasMonthly

| Meter |

SetpointsNotMetWithTemperaturesMonthly

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

ComfortReportSimple55Monthly

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

OccupantComfortDataSummaryMonthly

| OCCUP_GSW | OCCUP_GNW | OCCUP_OFFICE | OCCUP_GNE | OCCUP_GN1 | OCCUP_GN2 | OCCUP_GS1 | OCCUP_GS2 | OCCUP_MSW | OCCUP_MNW | OCCUP_MSE | OCCUP_MNE | OCCUP_MN1 | OCCUP_MN2 | OCCUP_MS1 | OCCUP_MS2 | OCCUP_TSW | OCCUP_TNW | OCCUP_TSE | OCCUP_TNE | OCCUP_TN1 | OCCUP_TN2 | OCCUP_TS1 | OCCUP_TS2 | OCCUP_T CORRIDOR | OCCUP_G CORRIDOR | OCCUP_M CORRIDOR |

DXReportMonthly

| SPLIT GSW HP COOLING COIL | SPLIT GNW HP COOLING COIL | SPLIT OFFICE HP COOLING COIL | SPLIT GNE HP COOLING COIL | SPLIT GN1 HP COOLING COIL | SPLIT GN2 HP COOLING COIL | SPLIT GS1 HP COOLING COIL | SPLIT GS2 HP COOLING COIL | SPLIT MSW HP COOLING COIL | SPLIT MNW HP COOLING COIL | SPLIT MSE HP COOLING COIL | SPLIT MNE HP COOLING COIL | SPLIT MN1 HP COOLING COIL | SPLIT MN2 HP COOLING COIL | SPLIT MS1 HP COOLING COIL | SPLIT MS2 HP COOLING COIL | SPLIT TSW HP COOLING COIL | SPLIT TNW HP COOLING COIL | SPLIT TSE HP COOLING COIL | SPLIT TNE HP COOLING COIL | SPLIT TN1 HP COOLING COIL | SPLIT TN2 HP COOLING COIL | SPLIT TS1 HP COOLING COIL | SPLIT TS2 HP COOLING COIL |

WindowReportMonthly

| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |

WindowEnergyReportMonthly

| GWINDOW1 S SWA | GWINDOW1 W SWA | GWINDOW1 W NWA | GWINDOW1 N NWA | GWINDOW1 S SEA | GWINDOW1 E SEA | GWINDOW1 E NEA | GWINDOW1 N NEA | GWINDOW1 N N1A | GWINDOW1 N N2A | GWINDOW1 S S1A | GWINDOW1 S S2A | MWINDOW1 S SWA | MWINDOW1 W SWA | MWINDOW1 W NWA | MWINDOW1 N NWA | MWINDOW1 S SEA | MWINDOW1 E SEA | MWINDOW1 E NEA | MWINDOW1 N NEA | MWINDOW1 N N1A | MWINDOW1 N N2A | MWINDOW1 S S1A | MWINDOW1 S S2A | TWINDOW1 S SWA | TWINDOW1 W SWA | TWINDOW1 W NWA | TWINDOW1 N NWA | TWINDOW1 S SEA | TWINDOW1 E SEA | TWINDOW1 E NEA | TWINDOW1 N NEA | TWINDOW1 N N1A | TWINDOW1 N N2A | TWINDOW1 S S1A | TWINDOW1 S S2A | TWINDOW14 | ENTRANCE DOOR | MWINDOW14 |

WindowZoneSummaryMonthly

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

WindowEnergyZoneSummaryMonthly

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

AverageOutdoorConditionsMonthly

| Environment |

OutdoorConditionsMaximumDryBulbMonthly

| Environment |

OutdoorConditionsMinimumDryBulbMonthly

| Environment |

OutdoorConditionsMaximumWetBulbMonthly

| Environment |

OutdoorConditionsMaximumDewPointMonthly

| Environment |

OutdoorGroundConditionsMonthly

| Environment |

WaterHeaterReportMonthly

| SWHSYS1 WATER HEATER |

DaylightingReportMonthly

| Environment |

CoilReportMonthly

| SPLIT GSW HEATING COIL | SPLIT GNW HEATING COIL | SPLIT OFFICE HEATING COIL | SPLIT GNE HEATING COIL | SPLIT GN1 HEATING COIL | SPLIT GN2 HEATING COIL | SPLIT GS1 HEATING COIL | SPLIT GS2 HEATING COIL | SPLIT MSW HEATING COIL | SPLIT MNW HEATING COIL | SPLIT MSE HEATING COIL | SPLIT MNE HEATING COIL | SPLIT MN1 HEATING COIL | SPLIT MN2 HEATING COIL | SPLIT MS1 HEATING COIL | SPLIT MS2 HEATING COIL | SPLIT TSW HEATING COIL | SPLIT TNW HEATING COIL | SPLIT TSE HEATING COIL | SPLIT TNE HEATING COIL | SPLIT TN1 HEATING COIL | SPLIT TN2 HEATING COIL | SPLIT TS1 HEATING COIL | SPLIT TS2 HEATING COIL | SPLIT GSW_SUPPHEATCOIL | SPLIT GNW_SUPPHEATCOIL | SPLIT OFFICE_SUPPHEATCOIL | SPLIT GNE_SUPPHEATCOIL | SPLIT GN1_SUPPHEATCOIL | SPLIT GN2_SUPPHEATCOIL | SPLIT GS1_SUPPHEATCOIL | SPLIT GS2_SUPPHEATCOIL | SPLIT MSW_SUPPHEATCOIL | SPLIT MNW_SUPPHEATCOIL | SPLIT MSE_SUPPHEATCOIL | SPLIT MNE_SUPPHEATCOIL | SPLIT MN1_SUPPHEATCOIL | SPLIT MN2_SUPPHEATCOIL | SPLIT MS1_SUPPHEATCOIL | SPLIT MS2_SUPPHEATCOIL | SPLIT TSW_SUPPHEATCOIL | SPLIT TNW_SUPPHEATCOIL | SPLIT TSE_SUPPHEATCOIL | SPLIT TNE_SUPPHEATCOIL | SPLIT TN1_SUPPHEATCOIL | SPLIT TN2_SUPPHEATCOIL | SPLIT TS1_SUPPHEATCOIL | SPLIT TS2_SUPPHEATCOIL | SPLIT GSW HP COOLING COIL | SPLIT GNW HP COOLING COIL | SPLIT OFFICE HP COOLING COIL | SPLIT GNE HP COOLING COIL | SPLIT GN1 HP COOLING COIL | SPLIT GN2 HP COOLING COIL | SPLIT GS1 HP COOLING COIL | SPLIT GS2 HP COOLING COIL | SPLIT MSW HP COOLING COIL | SPLIT MNW HP COOLING COIL | SPLIT MSE HP COOLING COIL | SPLIT MNE HP COOLING COIL | SPLIT MN1 HP COOLING COIL | SPLIT MN2 HP COOLING COIL | SPLIT MS1 HP COOLING COIL | SPLIT MS2 HP COOLING COIL | SPLIT TSW HP COOLING COIL | SPLIT TNW HP COOLING COIL | SPLIT TSE HP COOLING COIL | SPLIT TNE HP COOLING COIL | SPLIT TN1 HP COOLING COIL | SPLIT TN2 HP COOLING COIL | SPLIT TS1 HP COOLING COIL | SPLIT TS2 HP COOLING COIL |

PlantLoopDemandReportMonthly

| SWHSYS1 |

FanReportMonthly

| SPLIT GSW SUPPLY FAN | G SW APARTMENT ERV SUP FAN | G SW APARTMENT ERV EXH FAN | SPLIT GNW SUPPLY FAN | G NW APARTMENT ERV SUP FAN | G NW APARTMENT ERV EXH FAN | SPLIT OFFICE SUPPLY FAN | SPLIT GNE SUPPLY FAN | G NE APARTMENT ERV SUP FAN | G NE APARTMENT ERV EXH FAN | SPLIT GN1 SUPPLY FAN | G N1 APARTMENT ERV SUP FAN | G N1 APARTMENT ERV EXH FAN | SPLIT GN2 SUPPLY FAN | G N2 APARTMENT ERV SUP FAN | G N2 APARTMENT ERV EXH FAN | SPLIT GS1 SUPPLY FAN | G S1 APARTMENT ERV SUP FAN | G S1 APARTMENT ERV EXH FAN | SPLIT GS2 SUPPLY FAN | G S2 APARTMENT ERV SUP FAN | G S2 APARTMENT ERV EXH FAN | SPLIT MSW SUPPLY FAN | M SW APARTMENT ERV SUP FAN | M SW APARTMENT ERV EXH FAN | SPLIT MNW SUPPLY FAN | M NW APARTMENT ERV SUP FAN | M NW APARTMENT ERV EXH FAN | SPLIT MSE SUPPLY FAN | M SE APARTMENT ERV SUP FAN | M SE APARTMENT ERV EXH FAN | SPLIT MNE SUPPLY FAN | M NE APARTMENT ERV SUP FAN | M NE APARTMENT ERV EXH FAN | SPLIT MN1 SUPPLY FAN | M N1 APARTMENT ERV SUP FAN | M N1 APARTMENT ERV EXH FAN | SPLIT MN2 SUPPLY FAN | M N2 APARTMENT ERV SUP FAN | M N2 APARTMENT ERV EXH FAN | SPLIT MS1 SUPPLY FAN | M S1 APARTMENT ERV SUP FAN | M S1 APARTMENT ERV EXH FAN | SPLIT MS2 SUPPLY FAN | M S2 APARTMENT ERV SUP FAN | M S2 APARTMENT ERV EXH FAN | SPLIT TSW SUPPLY FAN | T SW APARTMENT ERV SUP FAN | T SW APARTMENT ERV EXH FAN | SPLIT TNW SUPPLY FAN | T NW APARTMENT ERV SUP FAN | T NW APARTMENT ERV EXH FAN | SPLIT TSE SUPPLY FAN | T SE APARTMENT ERV SUP FAN | T SE APARTMENT ERV EXH FAN | SPLIT TNE SUPPLY FAN | T NE APARTMENT ERV SUP FAN | T NE APARTMENT ERV EXH FAN | SPLIT TN1 SUPPLY FAN | T N1 APARTMENT ERV SUP FAN | T N1 APARTMENT ERV EXH FAN | SPLIT TN2 SUPPLY FAN | T N2 APARTMENT ERV SUP FAN | T N2 APARTMENT ERV EXH FAN | SPLIT TS1 SUPPLY FAN | T S1 APARTMENT ERV SUP FAN | T S1 APARTMENT ERV EXH FAN | SPLIT TS2 SUPPLY FAN | T S2 APARTMENT ERV SUP FAN | T S2 APARTMENT ERV EXH FAN |

PumpReportMonthly

| SWHSYS1 PUMP |

CondLoopDemandReportMonthly

| SWHSYS1 |

ZoneTemperatureOscillationReportMonthly

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

AirLoopSystemEnergyAndWaterUseMonthly

| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |

AirLoopSystemComponentLoadsMonthly

| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |

AirLoopSystemComponentEnergyUseMonthly

| SPLIT GSW | SPLIT GNW | SPLIT OFFICE | SPLIT GNE | SPLIT GN1 | SPLIT GN2 | SPLIT GS1 | SPLIT GS2 | SPLIT MSW | SPLIT MNW | SPLIT MSE | SPLIT MNE | SPLIT MN1 | SPLIT MN2 | SPLIT MS1 | SPLIT MS2 | SPLIT TSW | SPLIT TNW | SPLIT TSE | SPLIT TNE | SPLIT TN1 | SPLIT TN2 | SPLIT TS1 | SPLIT TS2 |

MechanicalVentilationLoadsMonthly

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT |

HeatEmissionsReportMonthly

| Environment |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

General

Value
Program Version and Build EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2024.07.03 12:27
RunPeriod RUNPERIOD 1
Weather File Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745
Latitude [deg] 32.17
Longitude [deg] -110.9
Elevation [m] 809.00
Time Zone -7.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1542.04 564.80 206.22 564.80 206.22
Above Ground Wall Area [m2] 1542.04 564.80 206.22 564.80 206.22
Window Opening Area [m2] 306.92 112.97 43.82 112.97 37.16
Gross Window-Wall Ratio [%] 19.90 20.00 21.25 20.00 18.02
Above Ground Window-Wall Ratio [%] 19.90 20.00 21.25 20.00 18.02


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1501.17 564.80 185.79 564.80 185.79
Above Ground Wall Area [m2] 1501.17 564.80 185.79 564.80 185.79
Window Opening Area [m2] 300.26 112.97 37.16 112.97 37.16
Gross Window-Wall Ratio [%] 20.00 20.00 20.00 20.00 20.00
Above Ground Window-Wall Ratio [%] 20.00 20.00 20.00 20.00 20.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Above Ground Gross Wall Area [m2] Underground Gross Wall Area [m2] Window Glass Area [m2] Opening Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 0.00 11.71 11.71 3.1215 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 0.00 11.71 11.71 3.1215 35.30 6.6700
OFFICE 88.25 Yes Yes 268.97 1.00 58.52 0.00 11.71 11.71 6.8737 18.58 6.6700
G NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 0.00 11.71 11.71 3.1215 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 0.00 7.06 7.06 3.1215 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 0.00 7.06 7.06 3.1215 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 0.00 7.06 7.06 3.1215 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 0.00 7.06 7.06 3.1215 35.30 6.6700
M SW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 0.00 11.71 11.71 3.1215 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 0.00 11.71 11.71 3.1215 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 0.00 11.71 11.71 3.1215 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 0.00 11.71 11.71 3.1215 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 0.00 7.06 7.06 3.1215 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 0.00 7.06 7.06 3.1215 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 0.00 7.06 7.06 3.1215 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 0.00 7.06 7.06 3.1215 35.30 6.6700
T SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 0.00 11.71 11.71 3.1215 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 0.00 11.71 11.71 3.1215 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 0.00 11.71 11.71 3.1215 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 0.00 11.71 11.71 3.1215 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 0.00 7.06 7.06 3.1215 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 0.00 7.06 7.06 3.1215 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 0.00 7.06 7.06 3.1215 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 0.00 7.06 7.06 3.1215 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 0.00 1.11 1.11 5.1587 18.58 0.0000
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 0.00 3.32 3.32 5.1587 18.58 340.5985
M CORRIDOR 77.66 No Yes 236.69 2.00 10.22 0.00 1.11 1.11 5.1587 18.58 0.0000
Total 3134.61     9553.84   1542.04 0.00 306.92 306.92 3.4291 31.67 14.4473
Conditioned Total 2823.98     8607.06   1501.17 0.00 300.26 300.26 3.2388 34.33 6.6700
Unconditioned Total 310.64     946.78   40.87 0.00 6.66 6.66 5.1587 18.58 85.1496
Not Part of Total 0.00     0.00   0.00 0.00 0.00 0.00      


Space Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Multipliers Zone Name Space Type Radiant/Solar Enclosure Name Lighting [W/m2] People [m2 per person] Plug and Process [W/m2] Tags
G SW APARTMENT 88.25 Yes Yes 1.00 G SW APARTMENT GENERAL G SW APARTMENT 3.1215 35.30 6.6700  
G NW APARTMENT 88.25 Yes Yes 1.00 G NW APARTMENT GENERAL G NW APARTMENT 3.1215 35.30 6.6700  
OFFICE 88.25 Yes Yes 1.00 OFFICE GENERAL OFFICE 6.8737 18.58 6.6700  
G NE APARTMENT 88.25 Yes Yes 1.00 G NE APARTMENT GENERAL G NE APARTMENT 3.1215 35.30 6.6700  
G N1 APARTMENT 88.25 Yes Yes 1.00 G N1 APARTMENT GENERAL G N1 APARTMENT 3.1215 35.30 6.6700  
G N2 APARTMENT 88.25 Yes Yes 1.00 G N2 APARTMENT GENERAL G N2 APARTMENT 3.1215 35.30 6.6700  
G S1 APARTMENT 88.25 Yes Yes 1.00 G S1 APARTMENT GENERAL G S1 APARTMENT 3.1215 35.30 6.6700  
G S2 APARTMENT 88.25 Yes Yes 1.00 G S2 APARTMENT GENERAL G S2 APARTMENT 3.1215 35.30 6.6700  
M SW APARTMENT 88.25 Yes Yes 2.00 M SW APARTMENT GENERAL M SW APARTMENT 3.1215 35.30 6.6700  
M NW APARTMENT 88.25 Yes Yes 2.00 M NW APARTMENT GENERAL M NW APARTMENT 3.1215 35.30 6.6700  
M SE APARTMENT 88.25 Yes Yes 2.00 M SE APARTMENT GENERAL M SE APARTMENT 3.1215 35.30 6.6700  
M NE APARTMENT 88.25 Yes Yes 2.00 M NE APARTMENT GENERAL M NE APARTMENT 3.1215 35.30 6.6700  
M N1 APARTMENT 88.25 Yes Yes 2.00 M N1 APARTMENT GENERAL M N1 APARTMENT 3.1215 35.30 6.6700  
M N2 APARTMENT 88.25 Yes Yes 2.00 M N2 APARTMENT GENERAL M N2 APARTMENT 3.1215 35.30 6.6700  
M S1 APARTMENT 88.25 Yes Yes 2.00 M S1 APARTMENT GENERAL M S1 APARTMENT 3.1215 35.30 6.6700  
M S2 APARTMENT 88.25 Yes Yes 2.00 M S2 APARTMENT GENERAL M S2 APARTMENT 3.1215 35.30 6.6700  
T SW APARTMENT 88.25 Yes Yes 1.00 T SW APARTMENT GENERAL T SW APARTMENT 3.1215 35.30 6.6700  
T NW APARTMENT 88.25 Yes Yes 1.00 T NW APARTMENT GENERAL T NW APARTMENT 3.1215 35.30 6.6700  
T SE APARTMENT 88.25 Yes Yes 1.00 T SE APARTMENT GENERAL T SE APARTMENT 3.1215 35.30 6.6700  
T NE APARTMENT 88.25 Yes Yes 1.00 T NE APARTMENT GENERAL T NE APARTMENT 3.1215 35.30 6.6700  
T N1 APARTMENT 88.25 Yes Yes 1.00 T N1 APARTMENT GENERAL T N1 APARTMENT 3.1215 35.30 6.6700  
T N2 APARTMENT 88.25 Yes Yes 1.00 T N2 APARTMENT GENERAL T N2 APARTMENT 3.1215 35.30 6.6700  
T S1 APARTMENT 88.25 Yes Yes 1.00 T S1 APARTMENT GENERAL T S1 APARTMENT 3.1215 35.30 6.6700  
T S2 APARTMENT 88.25 Yes Yes 1.00 T S2 APARTMENT GENERAL T S2 APARTMENT 3.1215 35.30 6.6700  
T CORRIDOR 77.66 No Yes 1.00 T CORRIDOR GENERAL T CORRIDOR 5.1587 18.58 0.0000  
G CORRIDOR 77.66 No Yes 1.00 G CORRIDOR GENERAL G CORRIDOR 5.1587 18.58 340.5985  
M CORRIDOR 77.66 No Yes 2.00 M CORRIDOR GENERAL M CORRIDOR 5.1587 18.58 0.0000  
Total 3134.61             3.4291 15.84 14.4473  
Conditioned Total 2823.98             3.2388 17.17 6.6700  
Unconditioned Total 310.64             5.1587 9.29 85.1496  
Not Part of Total 0.00             0.0000 0.00 0.0000  


Space Type Summary

Total Area [m2] Conditioned Area [m2] Unconditioned Area [m2] Not Part of Total Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
GENERAL 3134.61 2823.98 310.64 0.00 2.5982 41.91 12.9450
Total 3134.61 2823.98 310.64 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

End Uses

Electricity [W] Natural Gas [W] Gasoline [W] Diesel [W] Coal [W] Fuel Oil No 1 [W] Fuel Oil No 2 [W] Propane [W] Other Fuel 1 [W] Other Fuel 2 [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 28-JUN-16:19 22-JAN-07:49 - - - - - - - - - - 01-JAN-07:30
Heating 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 31651.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 2039.59 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 20787.24 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 10745.55 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 12.93 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 23106.97 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total End Uses 65237.17 23106.97 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Gasoline [W] Diesel [W] Coal [W] Fuel Oil No 1 [W] Fuel Oil No 2 [W] Propane [W] Other Fuel 1 [W] Other Fuel 2 [W] District Cooling [W] Steam [W] Water [m3/s]
Heating General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 31651.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting LightsWired 1769.68 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  LightsPlugIn 269.91 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment ElevatorLift 2318.63 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ElevatorLightsFan 26.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  MiscPlug 18442.28 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  General 10745.55 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps General 12.93 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Water Heater 0.00 23106.97 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators DCtoACInverter Ancillary 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Gasoline [GJ] Source Diesel [GJ] Source Coal [GJ] Source Fuel Oil No 1 [GJ] Source Fuel Oil No 2 [GJ] Source Propane [GJ] Source Other Fuel 1 [GJ] Source Other Fuel 2 [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 5.75 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 676.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 170.58 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 72.31 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1341.55 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 380.44 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 1.29 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 345.81 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 2648.32 345.81 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Gasoline [MJ/m2] Source Diesel [MJ/m2] Source Coal [MJ/m2] Source Fuel Oil No 1 [MJ/m2] Source Fuel Oil No 2 [MJ/m2] Source Propane [MJ/m2] Source Other Fuel 1 [MJ/m2] Source Other Fuel 2 [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 2.04 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 239.52 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 60.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 25.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 475.06 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 134.72 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 122.45 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 937.80 122.45 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Gasoline [MJ/m2] Source Diesel [MJ/m2] Source Coal [MJ/m2] Source Fuel Oil No 1 [MJ/m2] Source Fuel Oil No 2 [MJ/m2] Source Propane [MJ/m2] Source Other Fuel 1 [MJ/m2] Source Other Fuel 2 [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 1.83 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 215.78 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 54.42 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 23.07 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 427.98 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 121.37 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 110.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 844.86 110.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

ZoneHVAC:EnergyRecoveryVentilator

User-Specified Supply Air Flow Rate [m3/s] User-Specified Exhaust Air Flow Rate [m3/s]
G SW APARTMENT ERV 0.025955 0.025955
G NW APARTMENT ERV 0.025955 0.025955
G NE APARTMENT ERV 0.025955 0.025955
G N1 APARTMENT ERV 0.025955 0.025955
G N2 APARTMENT ERV 0.025955 0.025955
G S1 APARTMENT ERV 0.025955 0.025955
G S2 APARTMENT ERV 0.025955 0.025955
M SW APARTMENT ERV 0.051909 0.051909
M NW APARTMENT ERV 0.051909 0.051909
M SE APARTMENT ERV 0.051909 0.051909
M NE APARTMENT ERV 0.051909 0.051909
M N1 APARTMENT ERV 0.051909 0.051909
M N2 APARTMENT ERV 0.051909 0.051909
M S1 APARTMENT ERV 0.051909 0.051909
M S2 APARTMENT ERV 0.051909 0.051909
T SW APARTMENT ERV 0.025955 0.025955
T NW APARTMENT ERV 0.025955 0.025955
T SE APARTMENT ERV 0.025955 0.025955
T NE APARTMENT ERV 0.025955 0.025955
T N1 APARTMENT ERV 0.025955 0.025955
T N2 APARTMENT ERV 0.025955 0.025955
T S1 APARTMENT ERV 0.025955 0.025955
T S2 APARTMENT ERV 0.025955 0.025955
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Fan:OnOff

Design Size Maximum Flow Rate [m3/s]
G SW APARTMENT ERV SUP FAN 0.025955
G SW APARTMENT ERV EXH FAN 0.025955
G NW APARTMENT ERV SUP FAN 0.025955
G NW APARTMENT ERV EXH FAN 0.025955
G NE APARTMENT ERV SUP FAN 0.025955
G NE APARTMENT ERV EXH FAN 0.025955
G N1 APARTMENT ERV SUP FAN 0.025955
G N1 APARTMENT ERV EXH FAN 0.025955
G N2 APARTMENT ERV SUP FAN 0.025955
G N2 APARTMENT ERV EXH FAN 0.025955
G S1 APARTMENT ERV SUP FAN 0.025955
G S1 APARTMENT ERV EXH FAN 0.025955
G S2 APARTMENT ERV SUP FAN 0.025955
G S2 APARTMENT ERV EXH FAN 0.025955
M SW APARTMENT ERV SUP FAN 0.051909
M SW APARTMENT ERV EXH FAN 0.051909
M NW APARTMENT ERV SUP FAN 0.051909
M NW APARTMENT ERV EXH FAN 0.051909
M SE APARTMENT ERV SUP FAN 0.051909
M SE APARTMENT ERV EXH FAN 0.051909
M NE APARTMENT ERV SUP FAN 0.051909
M NE APARTMENT ERV EXH FAN 0.051909
M N1 APARTMENT ERV SUP FAN 0.051909
M N1 APARTMENT ERV EXH FAN 0.051909
M N2 APARTMENT ERV SUP FAN 0.051909
M N2 APARTMENT ERV EXH FAN 0.051909
M S1 APARTMENT ERV SUP FAN 0.051909
M S1 APARTMENT ERV EXH FAN 0.051909
M S2 APARTMENT ERV SUP FAN 0.051909
M S2 APARTMENT ERV EXH FAN 0.051909
T SW APARTMENT ERV SUP FAN 0.025955
T SW APARTMENT ERV EXH FAN 0.025955
T NW APARTMENT ERV SUP FAN 0.025955
T NW APARTMENT ERV EXH FAN 0.025955
T SE APARTMENT ERV SUP FAN 0.025955
T SE APARTMENT ERV EXH FAN 0.025955
T NE APARTMENT ERV SUP FAN 0.025955
T NE APARTMENT ERV EXH FAN 0.025955
T N1 APARTMENT ERV SUP FAN 0.025955
T N1 APARTMENT ERV EXH FAN 0.025955
T N2 APARTMENT ERV SUP FAN 0.025955
T N2 APARTMENT ERV EXH FAN 0.025955
T S1 APARTMENT ERV SUP FAN 0.025955
T S1 APARTMENT ERV EXH FAN 0.025955
T S2 APARTMENT ERV SUP FAN 0.025955
T S2 APARTMENT ERV EXH FAN 0.025955
SPLIT GSW SUPPLY FAN 0.341942
SPLIT GNW SUPPLY FAN 0.336228
SPLIT OFFICE SUPPLY FAN 0.409046
SPLIT GNE SUPPLY FAN 0.312386
SPLIT GN1 SUPPLY FAN 0.267858
SPLIT GN2 SUPPLY FAN 0.267436
SPLIT GS1 SUPPLY FAN 0.273160
SPLIT GS2 SUPPLY FAN 0.278950
SPLIT MSW SUPPLY FAN 0.778498
SPLIT MNW SUPPLY FAN 0.767751
SPLIT MSE SUPPLY FAN 0.714916
SPLIT MNE SUPPLY FAN 0.704314
SPLIT MN1 SUPPLY FAN 0.603883
SPLIT MN2 SUPPLY FAN 0.602815
SPLIT MS1 SUPPLY FAN 0.614169
SPLIT MS2 SUPPLY FAN 0.613207
SPLIT TSW SUPPLY FAN 0.449926
SPLIT TNW SUPPLY FAN 0.448902
SPLIT TSE SUPPLY FAN 0.403128
SPLIT TNE SUPPLY FAN 0.402042
SPLIT TN1 SUPPLY FAN 0.361091
SPLIT TN2 SUPPLY FAN 0.359639
SPLIT TS1 SUPPLY FAN 0.362882
SPLIT TS2 SUPPLY FAN 0.361434
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

HeatExchanger:AirToAir:SensibleAndLatent

Design Size Nominal Supply Air Flow Rate [m3/s]
G SW APARTMENT OA HEAT EXCHANGER 0.025955
G NW APARTMENT OA HEAT EXCHANGER 0.025955
G NE APARTMENT OA HEAT EXCHANGER 0.025955
G N1 APARTMENT OA HEAT EXCHANGER 0.025955
G N2 APARTMENT OA HEAT EXCHANGER 0.025955
G S1 APARTMENT OA HEAT EXCHANGER 0.025955
G S2 APARTMENT OA HEAT EXCHANGER 0.025955
M SW APARTMENT OA HEAT EXCHANGER 0.051909
M NW APARTMENT OA HEAT EXCHANGER 0.051909
M SE APARTMENT OA HEAT EXCHANGER 0.051909
M NE APARTMENT OA HEAT EXCHANGER 0.051909
M N1 APARTMENT OA HEAT EXCHANGER 0.051909
M N2 APARTMENT OA HEAT EXCHANGER 0.051909
M S1 APARTMENT OA HEAT EXCHANGER 0.051909
M S2 APARTMENT OA HEAT EXCHANGER 0.051909
T SW APARTMENT OA HEAT EXCHANGER 0.025955
T NW APARTMENT OA HEAT EXCHANGER 0.025955
T SE APARTMENT OA HEAT EXCHANGER 0.025955
T NE APARTMENT OA HEAT EXCHANGER 0.025955
T N1 APARTMENT OA HEAT EXCHANGER 0.025955
T N2 APARTMENT OA HEAT EXCHANGER 0.025955
T S1 APARTMENT OA HEAT EXCHANGER 0.025955
T S2 APARTMENT OA HEAT EXCHANGER 0.025955
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirTerminal:SingleDuct:ConstantVolume:NoReheat

Design Size Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.341942
G NW APARTMENT DIRECT AIR 0.336228
OFFICE DIRECT AIR 0.409046
G NE APARTMENT DIRECT AIR 0.312386
G N1 APARTMENT DIRECT AIR 0.267858
G N2 APARTMENT DIRECT AIR 0.267436
G S1 APARTMENT DIRECT AIR 0.273160
G S2 APARTMENT DIRECT AIR 0.278950
M SW APARTMENT DIRECT AIR 0.778498
M NW APARTMENT DIRECT AIR 0.767751
M SE APARTMENT DIRECT AIR 0.714916
M NE APARTMENT DIRECT AIR 0.704314
M N1 APARTMENT DIRECT AIR 0.603883
M N2 APARTMENT DIRECT AIR 0.602815
M S1 APARTMENT DIRECT AIR 0.614169
M S2 APARTMENT DIRECT AIR 0.613207
T SW APARTMENT DIRECT AIR 0.449926
T NW APARTMENT DIRECT AIR 0.448902
T SE APARTMENT DIRECT AIR 0.403128
T NE APARTMENT DIRECT AIR 0.402042
T N1 APARTMENT DIRECT AIR 0.361091
T N2 APARTMENT DIRECT AIR 0.359639
T S1 APARTMENT DIRECT AIR 0.362882
T S2 APARTMENT DIRECT AIR 0.361434
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC

Sum of Air Terminal Maximum Heating Flow Rates [m3/s] Sum of Air Terminal Minimum Heating Flow Rates [m3/s] Sum of Air Terminal Maximum Flow Rates [m3/s] Adjusted Heating Design Air Flow Rate [m3/s] Adjusted Cooling Design Air Flow Rate [m3/s] Adjusted Main Design Air Flow Rate [m3/s] User Heating Air Flow Ratio [] Calculated Heating Air Flow Ratio [] Design Supply Air Flow Rate [m3/s]
SPLIT GSW 0.341942 0.341942 0.341942 0.341942 0.341942 0.341942 1.00 1.00 0.341942
SPLIT GNW 0.336228 0.336228 0.336228 0.336228 0.336228 0.336228 1.00 1.00 0.336228
SPLIT OFFICE 0.409046 0.409046 0.409046 0.409046 0.409046 0.409046 1.00 1.000000 0.409046
SPLIT GNE 0.312386 0.312386 0.312386 0.312386 0.312386 0.312386 1.00 1.00 0.312386
SPLIT GN1 0.267858 0.267858 0.267858 0.267858 0.267858 0.267858 1.00 1.00 0.267858
SPLIT GN2 0.267436 0.267436 0.267436 0.267436 0.267436 0.267436 1.00 1.00 0.267436
SPLIT GS1 0.273160 0.273160 0.273160 0.273160 0.273160 0.273160 1.00 1.000000 0.273160
SPLIT GS2 0.278950 0.278950 0.278950 0.278950 0.278950 0.278950 1.00 1.00 0.278950
SPLIT MSW 0.778498 0.778498 0.778498 0.778498 0.778498 0.778498 1.00 1.00 0.778498
SPLIT MNW 0.767751 0.767751 0.767751 0.767751 0.767751 0.767751 1.00 1.00 0.767751
SPLIT MSE 0.714916 0.714916 0.714916 0.714916 0.714916 0.714916 1.00 1.00 0.714916
SPLIT MNE 0.704314 0.704314 0.704314 0.704314 0.704314 0.704314 1.00 1.00 0.704314
SPLIT MN1 0.603883 0.603883 0.603883 0.603883 0.603883 0.603883 1.00 1.00 0.603883
SPLIT MN2 0.602815 0.602815 0.602815 0.602815 0.602815 0.602815 1.00 1.00 0.602815
SPLIT MS1 0.614169 0.614169 0.614169 0.614169 0.614169 0.614169 1.00 1.00 0.614169
SPLIT MS2 0.613207 0.613207 0.613207 0.613207 0.613207 0.613207 1.00 1.00 0.613207
SPLIT TSW 0.449926 0.449926 0.449926 0.449926 0.449926 0.449926 1.00 1.00 0.449926
SPLIT TNW 0.448902 0.448902 0.448902 0.448902 0.448902 0.448902 1.00 1.00 0.448902
SPLIT TSE 0.403128 0.403128 0.403128 0.403128 0.403128 0.403128 1.00 1.000000 0.403128
SPLIT TNE 0.402042 0.402042 0.402042 0.402042 0.402042 0.402042 1.00 1.00 0.402042
SPLIT TN1 0.361091 0.361091 0.361091 0.361091 0.361091 0.361091 1.00 1.000000 0.361091
SPLIT TN2 0.359639 0.359639 0.359639 0.359639 0.359639 0.359639 1.00 1.00 0.359639
SPLIT TS1 0.362882 0.362882 0.362882 0.362882 0.362882 0.362882 1.00 1.000000 0.362882
SPLIT TS2 0.361434 0.361434 0.361434 0.361434 0.361434 0.361434 1.00 1.000000 0.361434
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
SPLIT GSW_OA_CONTROLLER 0.341942 0.025955
SPLIT GNW_OA_CONTROLLER 0.336228 0.025955
SPLIT OFFICE_OA_CONTROLLER 0.409046 0.038106
SPLIT GNE_OA_CONTROLLER 0.312386 0.025955
SPLIT GN1_OA_CONTROLLER 0.267858 0.025955
SPLIT GN2_OA_CONTROLLER 0.267436 0.025955
SPLIT GS1_OA_CONTROLLER 0.273160 0.025955
SPLIT GS2_OA_CONTROLLER 0.278950 0.025955
SPLIT MSW_OA_CONTROLLER 0.778498 0.051909
SPLIT MNW_OA_CONTROLLER 0.767751 0.051909
SPLIT MSE_OA_CONTROLLER 0.714916 0.051909
SPLIT MNE_OA_CONTROLLER 0.704314 0.051909
SPLIT MN1_OA_CONTROLLER 0.603883 0.051909
SPLIT MN2_OA_CONTROLLER 0.602815 0.051909
SPLIT MS1_OA_CONTROLLER 0.614169 0.051909
SPLIT MS2_OA_CONTROLLER 0.613207 0.051909
SPLIT TSW_OA_CONTROLLER 0.449926 0.025955
SPLIT TNW_OA_CONTROLLER 0.448902 0.025955
SPLIT TSE_OA_CONTROLLER 0.403128 0.025955
SPLIT TNE_OA_CONTROLLER 0.402042 0.025955
SPLIT TN1_OA_CONTROLLER 0.361091 0.025955
SPLIT TN2_OA_CONTROLLER 0.359639 0.025955
SPLIT TS1_OA_CONTROLLER 0.362882 0.025955
SPLIT TS2_OA_CONTROLLER 0.361434 0.025955
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC:UnitarySystem

Design Size Supply Air Flow Rate [m3/s] Design Size Heating Supply Air Flow Rate [m3/s] Design Size Cooling Supply Air Flow Rate [m3/s] Design Size No Load Supply Air Flow Rate [m3/s] Design Size Nominal Cooling Capacity [W] Design Size Nominal Heating Capacity [W] Design Size Maximum Supply Air Temperature [C] User-Specified Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
SPLIT GSW_UNITARY_PACKAGE_DX 0.341942 0.341942 0.341942 0.341942 5660.35 3792.44 40.00 5660.35 1.00
SPLIT GNW_UNITARY_PACKAGE_DX 0.336228 0.336228 0.336228 0.336228 5565.77 3729.07 40.00 5565.77 1.00
SPLIT OFFICE_UNITARY_PACKAGE_DX 0.409046 0.409046 0.409046 0.409046 6771.16 4536.68 40.00 6771.16 1.00
SPLIT GNE_UNITARY_PACKAGE_DX 0.312386 0.312386 0.312386 0.312386 5171.10 3464.63 40.00 5171.10 1.00
SPLIT GN1_UNITARY_PACKAGE_DX 0.267858 0.267858 0.267858 0.267858 4434.00 2970.78 40.00 4434.00 1.00
SPLIT GN2_UNITARY_PACKAGE_DX 0.267436 0.267436 0.267436 0.267436 4427.01 2966.10 40.00 4427.01 1.00
SPLIT GS1_UNITARY_PACKAGE_DX 0.273160 0.273160 0.273160 0.273160 4521.76 3029.58 40.00 4521.76 1.00
SPLIT GS2_UNITARY_PACKAGE_DX 0.278950 0.278950 0.278950 0.278950 4617.61 3093.80 40.00 4617.61 1.00
SPLIT MSW_UNITARY_PACKAGE_DX 0.778498 0.778498 0.778498 0.778498 12886.90 8634.22 40.00 12886.90 1.00
SPLIT MNW_UNITARY_PACKAGE_DX 0.767751 0.767751 0.767751 0.767751 12709.01 8515.04 40.00 12709.01 1.00
SPLIT MSE_UNITARY_PACKAGE_DX 0.714916 0.714916 0.714916 0.714916 11834.39 7929.04 40.00 11834.39 1.00
SPLIT MNE_UNITARY_PACKAGE_DX 0.704314 0.704314 0.704314 0.704314 11658.90 7811.46 40.00 11658.90 1.00
SPLIT MN1_UNITARY_PACKAGE_DX 0.603883 0.603883 0.603883 0.603883 9996.40 6697.59 40.00 9996.40 1.00
SPLIT MN2_UNITARY_PACKAGE_DX 0.602815 0.602815 0.602815 0.602815 9978.73 6685.75 40.00 9978.73 1.00
SPLIT MS1_UNITARY_PACKAGE_DX 0.614169 0.614169 0.614169 0.614169 10166.68 6811.68 40.00 10166.68 1.00
SPLIT MS2_UNITARY_PACKAGE_DX 0.613207 0.613207 0.613207 0.613207 10150.76 6801.01 40.00 10150.76 1.00
SPLIT TSW_UNITARY_PACKAGE_DX 0.449926 0.449926 0.449926 0.449926 7447.88 4990.08 40.00 7447.88 1.00
SPLIT TNW_UNITARY_PACKAGE_DX 0.448902 0.448902 0.448902 0.448902 7430.92 4978.72 40.00 7430.92 1.00
SPLIT TSE_UNITARY_PACKAGE_DX 0.403128 0.403128 0.403128 0.403128 6673.20 4471.05 40.00 6673.20 1.00
SPLIT TNE_UNITARY_PACKAGE_DX 0.402042 0.402042 0.402042 0.402042 6655.23 4459.00 40.00 6655.23 1.00
SPLIT TN1_UNITARY_PACKAGE_DX 0.361091 0.361091 0.361091 0.361091 5977.34 4004.82 40.00 5977.34 1.00
SPLIT TN2_UNITARY_PACKAGE_DX 0.359639 0.359639 0.359639 0.359639 5953.31 3988.72 40.00 5953.31 1.00
SPLIT TS1_UNITARY_PACKAGE_DX 0.362882 0.362882 0.362882 0.362882 6006.98 4024.68 40.00 6006.98 1.00
SPLIT TS2_UNITARY_PACKAGE_DX 0.361434 0.361434 0.361434 0.361434 5983.02 4008.62 40.00 5983.02 1.00
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Cooling:DX:SingleSpeed

Design Size Rated Air Flow Rate [m3/s] Design Size Gross Rated Total Cooling Capacity [W] Design Size Gross Rated Sensible Heat Ratio
SPLIT GSW HP COOLING COIL 0.341942 5660.35 0.800655
SPLIT GNW HP COOLING COIL 0.336228 5565.77 0.800655
SPLIT OFFICE HP COOLING COIL 0.409046 6771.16 0.800655
SPLIT GNE HP COOLING COIL 0.312386 5171.10 0.800655
SPLIT GN1 HP COOLING COIL 0.267858 4434.00 0.800655
SPLIT GN2 HP COOLING COIL 0.267436 4427.01 0.800655
SPLIT GS1 HP COOLING COIL 0.273160 4521.76 0.800655
SPLIT GS2 HP COOLING COIL 0.278950 4617.61 0.800655
SPLIT MSW HP COOLING COIL 0.778498 12886.90 0.800655
SPLIT MNW HP COOLING COIL 0.767751 12709.01 0.800655
SPLIT MSE HP COOLING COIL 0.714916 11834.39 0.800655
SPLIT MNE HP COOLING COIL 0.704314 11658.90 0.800655
SPLIT MN1 HP COOLING COIL 0.603883 9996.40 0.800655
SPLIT MN2 HP COOLING COIL 0.602815 9978.73 0.800655
SPLIT MS1 HP COOLING COIL 0.614169 10166.68 0.800655
SPLIT MS2 HP COOLING COIL 0.613207 10150.76 0.800655
SPLIT TSW HP COOLING COIL 0.449926 7447.88 0.800655
SPLIT TNW HP COOLING COIL 0.448902 7430.92 0.800655
SPLIT TSE HP COOLING COIL 0.403128 6673.20 0.800655
SPLIT TNE HP COOLING COIL 0.402042 6655.23 0.800655
SPLIT TN1 HP COOLING COIL 0.361091 5977.34 0.800655
SPLIT TN2 HP COOLING COIL 0.359639 5953.31 0.800655
SPLIT TS1 HP COOLING COIL 0.362882 6006.98 0.800655
SPLIT TS2 HP COOLING COIL 0.361434 5983.02 0.800655
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Heating:DX:SingleSpeed

Design Size Rated Air Flow Rate [m3/s] Design Size Gross Rated Heating Capacity [W]
SPLIT GSW HEATING COIL 0.341942 5660.35
SPLIT GNW HEATING COIL 0.336228 5565.77
SPLIT OFFICE HEATING COIL 0.409046 6771.16
SPLIT GNE HEATING COIL 0.312386 5171.10
SPLIT GN1 HEATING COIL 0.267858 4434.00
SPLIT GN2 HEATING COIL 0.267436 4427.01
SPLIT GS1 HEATING COIL 0.273160 4521.76
SPLIT GS2 HEATING COIL 0.278950 4617.61
SPLIT MSW HEATING COIL 0.778498 12886.90
SPLIT MNW HEATING COIL 0.767751 12709.01
SPLIT MSE HEATING COIL 0.714916 11834.39
SPLIT MNE HEATING COIL 0.704314 11658.90
SPLIT MN1 HEATING COIL 0.603883 9996.40
SPLIT MN2 HEATING COIL 0.602815 9978.73
SPLIT MS1 HEATING COIL 0.614169 10166.68
SPLIT MS2 HEATING COIL 0.613207 10150.76
SPLIT TSW HEATING COIL 0.449926 7447.88
SPLIT TNW HEATING COIL 0.448902 7430.92
SPLIT TSE HEATING COIL 0.403128 6673.20
SPLIT TNE HEATING COIL 0.402042 6655.23
SPLIT TN1 HEATING COIL 0.361091 5977.34
SPLIT TN2 HEATING COIL 0.359639 5953.31
SPLIT TS1 HEATING COIL 0.362882 6006.98
SPLIT TS2 HEATING COIL 0.361434 5983.02
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Heating:Electric

Design Size Nominal Capacity [W]
SPLIT GSW_SUPPHEATCOIL 5660.35
SPLIT GNW_SUPPHEATCOIL 5565.77
SPLIT OFFICE_SUPPHEATCOIL 6771.16
SPLIT GNE_SUPPHEATCOIL 5171.10
SPLIT GN1_SUPPHEATCOIL 4434.00
SPLIT GN2_SUPPHEATCOIL 4427.01
SPLIT GS1_SUPPHEATCOIL 4521.76
SPLIT GS2_SUPPHEATCOIL 4617.61
SPLIT MSW_SUPPHEATCOIL 12886.90
SPLIT MNW_SUPPHEATCOIL 12709.01
SPLIT MSE_SUPPHEATCOIL 11834.39
SPLIT MNE_SUPPHEATCOIL 11658.90
SPLIT MN1_SUPPHEATCOIL 9996.40
SPLIT MN2_SUPPHEATCOIL 9978.73
SPLIT MS1_SUPPHEATCOIL 10166.68
SPLIT MS2_SUPPHEATCOIL 10150.76
SPLIT TSW_SUPPHEATCOIL 7447.88
SPLIT TNW_SUPPHEATCOIL 7430.92
SPLIT TSE_SUPPHEATCOIL 6673.20
SPLIT TNE_SUPPHEATCOIL 6655.23
SPLIT TN1_SUPPHEATCOIL 5977.34
SPLIT TN2_SUPPHEATCOIL 5953.31
SPLIT TS1_SUPPHEATCOIL 6006.98
SPLIT TS2_SUPPHEATCOIL 5983.02
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SWHSYS1 0.000101 0.012145
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Pump:ConstantSpeed

Design Flow Rate [m3/s] Design Power Consumption [W]
SWHSYS1 PUMP 0.000101 12.93
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

WaterHeater:Mixed

Use Side Design Flow Rate [m3/s]
SWHSYS1 WATER HEATER 0.000101
User-Specified values were used. Design Size values were used if no User-Specified values were provided.


Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW1 S SWA |
G WWALL SWA GWINDOW1 W SWA |
G NWALL NWA GWINDOW1 N NWA |
G WWALL NWA GWINDOW1 W NWA |
G SWALL SEA GWINDOW1 S SEA |
G EWALL SEA GWINDOW1 E SEA |
G NWALL NEA GWINDOW1 N NEA |
G EWALL NEA GWINDOW1 E NEA |
G NWALL N1A GWINDOW1 N N1A |
G NWALL N2A GWINDOW1 N N2A |
G SWALL S1A GWINDOW1 S S1A |
G SWALL S2A GWINDOW1 S S2A |
M WWALL SWA MWINDOW1 W SWA |
M SWALL SWA MWINDOW1 S SWA |
M NWALL NWA MWINDOW1 N NWA |
M WWALL NWA MWINDOW1 W NWA |
M EWALL SEA MWINDOW1 E SEA |
M SWALL SEA MWINDOW1 S SEA |
M NWALL NEA MWINDOW1 N NEA |
M EWALL NEA MWINDOW1 E NEA |
M NWALL N1A MWINDOW1 N N1A |
M NWALL N2A MWINDOW1 N N2A |
M SWALL S1A MWINDOW1 S S1A |
M SWALL S2A MWINDOW1 S S2A |
T WWALL SWA TWINDOW1 W SWA |
T SWALL SWA TWINDOW1 S SWA |
T NWALL NWA TWINDOW1 N NWA |
T WWALL NWA TWINDOW1 W NWA |
T EWALL SEA TWINDOW1 E SEA |
T SWALL SEA TWINDOW1 S SEA |
T NWALL NEA TWINDOW1 N NEA |
T EWALL NEA TWINDOW1 E NEA |
T NWALL N1A TWINDOW1 N N1A |
T NWALL N2A TWINDOW1 N N2A |
T SWALL S1A TWINDOW1 S S1A |
T SWALL S2A TWINDOW1 S S2A |
T EWALL C TWINDOW14 |
G EWALL C ENTRANCE DOOR |
M EWALL C MWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: Initialization Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Version

Version ID
1 22.1


Timesteps per Hour

#TimeSteps Minutes per TimeStep {minutes}
1 6 10


System Convergence Limits

Minimum System TimeStep {minutes} Max HVAC Iterations Minimum Plant Iterations Maximum Plant Iterations
1 1 20 2 8


Simulation Control

Do Zone Sizing Do System Sizing Do Plant Sizing Do Design Days Do Weather Simulation Do HVAC Sizing Simulation
1 Yes Yes No No Yes No


Performance Precision Tradeoffs

Use Coil Direct Simulation Zone Radiant Exchange Algorithm Override Mode Number of Timestep In Hour Force Euler Method Minimum Number of Warmup Days Force Suppress All Begin Environment Resets Minimum System Timestep MaxZoneTempDiff MaxAllowedDelTemp
1 No ScriptF Normal 6 No 1 No 1.0 0.300 2.0000E-003


Output Reporting Tolerances

Tolerance for Time Heating Setpoint Not Met Tolerance for Zone Cooling Setpoint Not Met Time
1 0.556 0.556


Site:GroundTemperature:BuildingSurface

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00


Site:GroundTemperature:FCfactorMethod

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 20.90 15.40 11.90 14.80 12.70 15.40 23.30 26.30 31.20 30.40 29.80 27.80


Site:GroundTemperature:Shallow

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00


Site:GroundTemperature:Deep

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00


Site:GroundReflectance

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Site:GroundReflectance:SnowModifier

Normal Daylighting {dimensionless}
1 1.000 1.000


Site:GroundReflectance:Snow

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Site:GroundReflectance:Snow:Daylighting

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Environment:Weather Station

Wind Sensor Height Above Ground {m} Wind Speed Profile Exponent {} Wind Speed Profile Boundary Layer Thickness {m} Air Temperature Sensor Height Above Ground {m} Wind Speed Modifier Coefficient-Internal Temperature Modifier Coefficient-Internal
1 10.000 0.140 270.000 1.500 1.586 9.750E-003


Site:Location

Location Name Latitude {N+/S- Deg} Longitude {E+/W- Deg} Time Zone Number {GMT+/-} Elevation {m} Standard Pressure at Elevation {Pa} Standard RhoAir at Elevation
1 Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745 32.17 -110.88 -7.00 809.00 91976 1.0932


Site Water Mains Temperature Information

Calculation Method{} Water Mains Temperature Schedule Name{} Annual Average Outdoor Air Temperature{C} Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} Fixed Default Water Mains Temperature{C}
1 Correlation NA 21.66 19.30 NA


Building Information

Building Name North Axis {deg} Terrain Loads Convergence Tolerance Value Temperature Convergence Tolerance Value Solar Distribution Maximum Number of Warmup Days Minimum Number of Warmup Days
1 ApartmentMidRise 0.000 City 4.00000E-002 0.40000 FullExterior 25 6


Inside Convection Algorithm

Algorithm {Simple
TARP
CeilingDiffuser
AdaptiveConvectionAlgorithm}
1 TARP


Outside Convection Algorithm

Algorithm {SimpleCombined
TARP
MoWitt
DOE-2
AdaptiveConvectionAlgorithm}
1 TARP


Sky Radiance Distribution

Value {Anisotropic}
1 Anisotropic


Zone Air Solution Algorithm

Value {ThirdOrderBackwardDifference
AnalyticalSolution
EulerMethod}
1 ThirdOrderBackwardDifference


Zone Air Carbon Dioxide Balance Simulation

Simulation {Yes/No} Carbon Dioxide Concentration
1 No N/A


Zone Air Generic Contaminant Balance Simulation

Simulation {Yes/No} Generic Contaminant Concentration
1 No N/A


Zone Air Mass Flow Balance Simulation

Enforce Mass Balance



Adjust Zone Mixing and Return {AdjustMixingOnly
AdjustReturnOnly
AdjustMixingThenReturn
AdjustReturnThenMixing
None}
Adjust Zone Infiltration {AddInfiltration
AdjustInfiltration
None}

Infiltration Zones {MixingSourceZonesOnly
AllZones}


1 No N/A N/A N/A


HVACSystemRootFindingAlgorithm

Value {RegulaFalsi
Bisection
BisectionThenRegulaFalsi
RegulaFalsiThenBisection}
1 RegulaFalsi


Environment:Site Atmospheric Variation

Wind Speed Profile Exponent {} Wind Speed Profile Boundary Layer Thickness {m} Air Temperature Gradient Coefficient {K/m}
1 0.330 460.000 6.500000E-003


Surface Geometry

Starting Corner Vertex Input Direction Coordinate System Daylight Reference Point Coordinate System Rectangular (Simple) Surface Coordinate System
1 LowerLeftCorner Clockwise RelativeCoordinateSystem RelativeCoordinateSystem RelativeToZoneOrigin


Surface Heat Transfer Algorithm

Value {CTF - ConductionTransferFunction
EMPD - MoisturePenetrationDepthConductionTransferFunction
CondFD - ConductionFiniteDifference
HAMT - CombinedHeatAndMoistureFiniteElement} - Description
Inside Surface Max Temperature Limit{C}


Surface Convection Coefficient Lower Limit {W/m2-K}


Surface Convection Coefficient Upper Limit {W/m2-K}


1 CTF - ConductionTransferFunction 200 0.10 1000.0


Shading Summary

Number of Fixed Detached Shades Number of Building Detached Shades Number of Attached Shades
1 0 0 0


Zone Summary

Number of Zones Number of Zone Surfaces Number of SubSurfaces
1 27 243 39


Zone Information

Zone Name North Axis {deg} Origin X-Coordinate {m} Origin Y-Coordinate {m} Origin Z-Coordinate {m} Centroid X-Coordinate {m} Centroid Y-Coordinate {m} Centroid Z-Coordinate {m} Type Zone Multiplier Zone List Multiplier Minimum X {m} Maximum X {m} Minimum Y {m} Maximum Y {m} Minimum Z {m} Maximum Z {m} Ceiling Height {m} Volume {m3} Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} Floor Area {m2} Exterior Gross Wall Area {m2} Exterior Net Wall Area {m2} Exterior Window Area {m2} Number of Surfaces Number of SubSurfaces Number of Shading SubSurfaces Part of Total Building Area
1 G SW APARTMENT 0.0 0.00 0.00 0.00 5.79 3.81 1.52 1 1 1 0.00 11.58 0.00 7.62 0.00 3.05 3.05 268.97 TARP TARP 88.25 58.52 46.82 11.71 6 2 0 Yes
2 G NW APARTMENT 0.0 0.00 9.30 0.00 5.79 13.11 1.52 1 1 1 0.00 11.58 9.30 16.92 0.00 3.05 3.05 268.97 TARP TARP 88.25 58.52 46.82 11.71 6 2 0 Yes
3 OFFICE 0.0 34.75 0.00 0.00 40.54 3.81 1.52 1 1 1 34.75 46.33 0.00 7.62 0.00 3.05 3.05 268.97 TARP TARP 88.25 58.52 46.82 11.71 6 2 0 Yes
4 G NE APARTMENT 0.0 34.75 9.30 0.00 40.54 13.11 1.52 1 1 1 34.75 46.33 9.30 16.92 0.00 3.05 3.05 268.97 TARP TARP 88.25 58.52 46.82 11.71 6 2 0 Yes
5 G N1 APARTMENT 0.0 11.58 9.30 0.00 17.37 13.11 1.52 1 1 1 11.58 23.16 9.30 16.92 0.00 3.05 3.05 268.97 TARP TARP 88.25 35.30 28.24 7.06 6 1 0 Yes
6 G N2 APARTMENT 0.0 23.16 9.30 0.00 28.95 13.11 1.52 1 1 1 23.16 34.75 9.30 16.92 0.00 3.05 3.05 268.97 TARP TARP 88.25 35.30 28.24 7.06 6 1 0 Yes
7 G S1 APARTMENT 0.0 11.58 0.00 0.00 17.37 3.81 1.52 1 1 1 11.58 23.16 0.00 7.62 0.00 3.05 3.05 268.97 TARP TARP 88.25 35.30 28.24 7.06 6 1 0 Yes
8 G S2 APARTMENT 0.0 23.16 0.00 0.00 28.95 3.81 1.52 1 1 1 23.16 34.75 0.00 7.62 0.00 3.05 3.05 268.97 TARP TARP 88.25 35.30 28.24 7.06 6 1 0 Yes
9 M SW APARTMENT 0.0 0.00 0.00 3.05 5.79 3.81 4.57 1 1 2 0.00 11.58 0.00 7.62 3.05 6.10 3.05 268.97 TARP TARP 88.25 58.52 46.82 11.71 6 2 0 Yes
10 M NW APARTMENT 0.0 0.00 9.30 3.05 5.79 13.11 4.57 1 1 2 0.00 11.58 9.30 16.92 3.05 6.10 3.05 268.97 TARP TARP 88.25 58.52 46.82 11.71 6 2 0 Yes
11 M SE APARTMENT 0.0 34.75 0.00 3.05 40.54 3.81 4.57 1 1 2 34.75 46.33 0.00 7.62 3.05 6.10 3.05 268.97 TARP TARP 88.25 58.52 46.82 11.71 6 2 0 Yes
12 M NE APARTMENT 0.0 34.75 9.30 3.05 40.54 13.11 4.57 1 1 2 34.75 46.33 9.30 16.92 3.05 6.10 3.05 268.97 TARP TARP 88.25 58.52 46.82 11.71 6 2 0 Yes
13 M N1 APARTMENT 0.0 11.58 9.30 3.05 17.37 13.11 4.57 1 1 2 11.58 23.16 9.30 16.92 3.05 6.10 3.05 268.97 TARP TARP 88.25 35.30 28.24 7.06 6 1 0 Yes
14 M N2 APARTMENT 0.0 23.16 9.30 3.05 28.95 13.11 4.57 1 1 2 23.16 34.75 9.30 16.92 3.05 6.10 3.05 268.97 TARP TARP 88.25 35.30 28.24 7.06 6 1 0 Yes
15 M S1 APARTMENT 0.0 11.58 0.00 3.05 17.37 3.81 4.57 1 1 2 11.58 23.16 0.00 7.62 3.05 6.10 3.05 268.97 TARP TARP 88.25 35.30 28.24 7.06 6 1 0 Yes
16 M S2 APARTMENT 0.0 23.16 0.00 3.05 28.95 3.81 4.57 1 1 2 23.16 34.75 0.00 7.62 3.05 6.10 3.05 268.97 TARP TARP 88.25 35.30 28.24 7.06 6 1 0 Yes
17 T SW APARTMENT 0.0 0.00 0.00 9.14 5.79 3.81 10.67 1 1 1 0.00 11.58 0.00 7.62 9.14 12.19 3.05 268.97 TARP TARP 88.25 58.52 46.82 11.71 6 2 0 Yes
18 T NW APARTMENT 0.0 0.00 9.30 9.14 5.79 13.11 10.67 1 1 1 0.00 11.58 9.30 16.92 9.14 12.19 3.05 268.97 TARP TARP 88.25 58.52 46.82 11.71 6 2 0 Yes
19 T SE APARTMENT 0.0 34.75 0.00 9.14 40.54 3.81 10.67 1 1 1 34.75 46.33 0.00 7.62 9.14 12.19 3.05 268.97 TARP TARP 88.25 58.52 46.82 11.71 6 2 0 Yes
20 T NE APARTMENT 0.0 34.75 9.30 9.14 40.54 13.11 10.67 1 1 1 34.75 46.33 9.30 16.92 9.14 12.19 3.05 268.97 TARP TARP 88.25 58.52 46.82 11.71 6 2 0 Yes
21 T N1 APARTMENT 0.0 11.58 9.30 9.14 17.37 13.11 10.67 1 1 1 11.58 23.16 9.30 16.92 9.14 12.19 3.05 268.97 TARP TARP 88.25 35.30 28.24 7.06 6 1 0 Yes
22 T N2 APARTMENT 0.0 23.16 9.30 9.14 28.95 13.11 10.67 1 1 1 23.16 34.75 9.30 16.92 9.14 12.19 3.05 268.97 TARP TARP 88.25 35.30 28.24 7.06 6 1 0 Yes
23 T S1 APARTMENT 0.0 11.58 0.00 9.14 17.37 3.81 10.67 1 1 1 11.58 23.16 0.00 7.62 9.14 12.19 3.05 268.97 TARP TARP 88.25 35.30 28.24 7.06 6 1 0 Yes
24 T S2 APARTMENT 0.0 23.16 0.00 9.14 28.95 3.81 10.67 1 1 1 23.16 34.75 0.00 7.62 9.14 12.19 3.05 268.97 TARP TARP 88.25 35.30 28.24 7.06 6 1 0 Yes
25 T CORRIDOR 0.0 0.00 7.62 9.14 23.16 8.46 10.67 1 1 1 0.00 46.33 7.62 9.30 9.14 12.19 3.05 236.69 TARP TARP 77.66 10.22 9.10 1.11 12 1 0 Yes
26 G CORRIDOR 0.0 0.00 7.62 0.00 23.16 8.46 1.52 1 1 1 0.00 46.33 7.62 9.30 0.00 3.05 3.05 236.69 TARP TARP 77.66 10.22 6.90 3.32 12 1 0 Yes
27 M CORRIDOR 0.0 0.00 7.62 3.05 23.16 8.46 4.57 1 1 2 0.00 46.33 7.62 9.30 3.05 6.10 3.05 236.69 TARP TARP 77.66 10.22 9.10 1.11 12 1 0 Yes


Zone Internal Gains Nominal

Zone Name Floor Area {m2} # Occupants Area per Occupant {m2/person} Occupant per Area {person/m2} Interior Lighting {W/m2} Electric Load {W/m2} Gas Load {W/m2} Other Load {W/m2} Hot Water Eq {W/m2} Steam Equipment {W/m2} Sum Loads per Area {W/m2} Outdoor Controlled Baseboard Heat
1 G SW APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
2 G NW APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
3 OFFICE 88.25 4.7 18.581 5.382E-002 6.874 6.670 0.000 0.000 0.000 0.000 13.544 No
4 G NE APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
5 G N1 APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
6 G N2 APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
7 G S1 APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
8 G S2 APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
9 M SW APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
10 M NW APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
11 M SE APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
12 M NE APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
13 M N1 APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
14 M N2 APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
15 M S1 APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
16 M S2 APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
17 T SW APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
18 T NW APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
19 T SE APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
20 T NE APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
21 T N1 APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
22 T N2 APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
23 T S1 APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
24 T S2 APARTMENT 88.25 2.5 35.300 2.833E-002 3.122 6.670 0.000 0.000 0.000 0.000 9.792 No
25 T CORRIDOR 77.66 4.2 18.579 5.382E-002 5.159 0.000 0.000 0.000 0.000 0.000 5.159 No
26 G CORRIDOR 77.66 4.2 18.579 5.382E-002 5.159 340.598 0.000 0.000 0.000 0.000 345.757 No
27 M CORRIDOR 77.66 4.2 18.579 5.382E-002 5.159 0.000 0.000 0.000 0.000 0.000 5.159 No


People Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Number of People {} People/Floor Area {person/m2} Floor Area per person {m2/person} Fraction Radiant Fraction Convected Sensible Fraction Calculation Activity level ASHRAE 55 Warnings Carbon Dioxide Generation Rate Nominal Minimum Number of People Nominal Maximum Number of People
1 OCCUP_GSW OCC_APT_SCH_WORKING_FAMILY G SW APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 0 3
2 OCCUP_GNW OCC_APT_SCH_STAY_HOME_FAMILY G NW APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 1 3
3 OCCUP_OFFICE OCC_OFF_W_SB_SCH OFFICE 88.25 4.7 4.7 5.382E-002 18.581 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 0 5
4 OCCUP_GNE OCC_APT_SCH_STAY_HOME_FAMILY G NE APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 1 3
5 OCCUP_GN1 OCC_APT_SCH_STAY_HOME_FAMILY G N1 APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 1 3
6 OCCUP_GN2 OCC_APT_SCH_STAY_HOME_FAMILY G N2 APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 1 3
7 OCCUP_GS1 OCC_APT_SCH_WORKING_FAMILY G S1 APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 0 3
8 OCCUP_GS2 OCC_APT_SCH_WORKING_FAMILY G S2 APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 0 3
9 OCCUP_MSW OCC_APT_SCH_WORKING_FAMILY M SW APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 0 3
10 OCCUP_MNW OCC_APT_SCH_STAY_HOME_FAMILY M NW APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 1 3
11 OCCUP_MSE OCC_APT_SCH_WORKING_FAMILY M SE APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 0 3
12 OCCUP_MNE OCC_APT_SCH_STAY_HOME_FAMILY M NE APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 1 3
13 OCCUP_MN1 OCC_APT_SCH_STAY_HOME_FAMILY M N1 APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 1 3
14 OCCUP_MN2 OCC_APT_SCH_STAY_HOME_FAMILY M N2 APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 1 3
15 OCCUP_MS1 OCC_APT_SCH_WORKING_FAMILY M S1 APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 0 3
16 OCCUP_MS2 OCC_APT_SCH_WORKING_FAMILY M S2 APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 0 3
17 OCCUP_TSW OCC_APT_SCH_WORKING_FAMILY T SW APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 0 3
18 OCCUP_TNW OCC_APT_SCH_STAY_HOME_FAMILY T NW APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 1 3
19 OCCUP_TSE OCC_APT_SCH_WORKING_FAMILY T SE APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 0 3
20 OCCUP_TNE OCC_APT_SCH_STAY_HOME_FAMILY T NE APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 1 3
21 OCCUP_TN1 OCC_APT_SCH_STAY_HOME_FAMILY T N1 APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 1 3
22 OCCUP_TN2 OCC_APT_SCH_STAY_HOME_FAMILY T N2 APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 1 3
23 OCCUP_TS1 OCC_APT_SCH_WORKING_FAMILY T S1 APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 0 3
24 OCCUP_TS2 OCC_APT_SCH_WORKING_FAMILY T S2 APARTMENT 88.25 2.5 2.5 2.833E-002 35.300 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 0 3
25 OCCUP_T CORRIDOR OCC_APT_SCH_CORRIDOR T CORRIDOR 77.66 4.2 4.2 5.382E-002 18.579 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 1 4
26 OCCUP_G CORRIDOR OCC_APT_SCH_CORRIDOR G CORRIDOR 77.66 4.2 4.2 5.382E-002 18.579 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 1 4
27 OCCUP_M CORRIDOR OCC_APT_SCH_CORRIDOR M CORRIDOR 77.66 4.2 4.2 5.382E-002 18.579 1.000 0.000 AutoCalculate ACTIVITY SCHEDULE No 3.8200E-008 1 4


Lights Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Lighting Level {W} Lights/Floor Area {W/m2} Lights per person {W/person} Fraction Return Air Fraction Radiant Fraction Short Wave Fraction Convected Fraction Replaceable End-Use Category Nominal Minimum Lighting Level {W} Nominal Maximum Lighting Level {W}
1 LIGHTING_HARDWIRED_GSW LTG_SCH_APARTMENT_HARDWIRED G SW APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
2 LIGHTING_HARDWIRED_GNW LTG_SCH_APARTMENT_HARDWIRED G NW APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
3 LIGHTING_HARDWIRED_OFFICE LTG_SCH_OFFICE OFFICE 88.25 4.7 606.600 6.874 127.718 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 606.600
4 LIGHTING_HARDWIRED_GNE LTG_SCH_APARTMENT_HARDWIRED G NE APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
5 LIGHTING_HARDWIRED_GN1 LTG_SCH_APARTMENT_HARDWIRED G N1 APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
6 LIGHTING_HARDWIRED_GN2 LTG_SCH_APARTMENT_HARDWIRED G N2 APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
7 LIGHTING_HARDWIRED_GS1 LTG_SCH_APARTMENT_HARDWIRED G S1 APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
8 LIGHTING_HARDWIRED_GS2 LTG_SCH_APARTMENT_HARDWIRED G S2 APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
9 LIGHTING_HARDWIRED_MSW LTG_SCH_APARTMENT_HARDWIRED M SW APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
10 LIGHTING_HARDWIRED_MNW LTG_SCH_APARTMENT_HARDWIRED M NW APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
11 LIGHTING_HARDWIRED_MSE LTG_SCH_APARTMENT_HARDWIRED M SE APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
12 LIGHTING_HARDWIRED_MNE LTG_SCH_APARTMENT_HARDWIRED M NE APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
13 LIGHTING_HARDWIRED_MN1 LTG_SCH_APARTMENT_HARDWIRED M N1 APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
14 LIGHTING_HARDWIRED_MN2 LTG_SCH_APARTMENT_HARDWIRED M N2 APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
15 LIGHTING_HARDWIRED_MS1 LTG_SCH_APARTMENT_HARDWIRED M S1 APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
16 LIGHTING_HARDWIRED_MS2 LTG_SCH_APARTMENT_HARDWIRED M S2 APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
17 LIGHTING_HARDWIRED_TSW LTG_SCH_APARTMENT_HARDWIRED T SW APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
18 LIGHTING_HARDWIRED_TNW LTG_SCH_APARTMENT_HARDWIRED T NW APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
19 LIGHTING_HARDWIRED_TSE LTG_SCH_APARTMENT_HARDWIRED T SE APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
20 LIGHTING_HARDWIRED_TNE LTG_SCH_APARTMENT_HARDWIRED T NE APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
21 LIGHTING_HARDWIRED_TN1 LTG_SCH_APARTMENT_HARDWIRED T N1 APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
22 LIGHTING_HARDWIRED_TN2 LTG_SCH_APARTMENT_HARDWIRED T N2 APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
23 LIGHTING_HARDWIRED_TS1 LTG_SCH_APARTMENT_HARDWIRED T S1 APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
24 LIGHTING_HARDWIRED_TS2 LTG_SCH_APARTMENT_HARDWIRED T S2 APARTMENT 88.25 2.5 189.981 2.153 75.993 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 189.981
25 LIGHTING_HARDWIRED_GC LTG_SCH_CORRIDOR G CORRIDOR 77.66 4.2 400.623 5.159 95.843 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 400.623
26 LIGHTING_HARDWIRED_MC LTG_SCH_CORRIDOR M CORRIDOR 77.66 4.2 400.623 5.159 95.843 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 400.623
27 LIGHTING_HARDWIRED_TC LTG_SCH_CORRIDOR T CORRIDOR 77.66 4.2 400.623 5.159 95.843 0.000 0.600 0.200 0.200 1.000 LightsWired 0.000 400.623
28 LIGHTING_PLUGIN_GSW LTG_SCH_APARTMENT_PLUGIN G SW APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
29 LIGHTING_PLUGIN_GNW LTG_SCH_APARTMENT_PLUGIN G NW APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
30 LIGHTING_PLUGIN_GNE LTG_SCH_APARTMENT_PLUGIN G NE APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
31 LIGHTING_PLUGIN_GN1 LTG_SCH_APARTMENT_PLUGIN G N1 APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
32 LIGHTING_PLUGIN_GN2 LTG_SCH_APARTMENT_PLUGIN G N2 APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
33 LIGHTING_PLUGIN_GS1 LTG_SCH_APARTMENT_PLUGIN G S1 APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
34 LIGHTING_PLUGIN_GS2 LTG_SCH_APARTMENT_PLUGIN G S2 APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
35 LIGHTING_PLUGIN_MSW LTG_SCH_APARTMENT_PLUGIN M SW APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
36 LIGHTING_PLUGIN_MNW LTG_SCH_APARTMENT_PLUGIN M NW APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
37 LIGHTING_PLUGIN_MSE LTG_SCH_APARTMENT_PLUGIN M SE APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
38 LIGHTING_PLUGIN_MNE LTG_SCH_APARTMENT_PLUGIN M NE APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
39 LIGHTING_PLUGIN_MN1 LTG_SCH_APARTMENT_PLUGIN M N1 APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
40 LIGHTING_PLUGIN_MN2 LTG_SCH_APARTMENT_PLUGIN M N2 APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
41 LIGHTING_PLUGIN_MS1 LTG_SCH_APARTMENT_PLUGIN M S1 APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
42 LIGHTING_PLUGIN_MS2 LTG_SCH_APARTMENT_PLUGIN M S2 APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
43 LIGHTING_PLUGIN_TSW LTG_SCH_APARTMENT_PLUGIN T SW APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
44 LIGHTING_PLUGIN_TNW LTG_SCH_APARTMENT_PLUGIN T NW APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
45 LIGHTING_PLUGIN_TSE LTG_SCH_APARTMENT_PLUGIN T SE APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
46 LIGHTING_PLUGIN_TNE LTG_SCH_APARTMENT_PLUGIN T NE APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
47 LIGHTING_PLUGIN_TN1 LTG_SCH_APARTMENT_PLUGIN T N1 APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
48 LIGHTING_PLUGIN_TN2 LTG_SCH_APARTMENT_PLUGIN T N2 APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
49 LIGHTING_PLUGIN_TS1 LTG_SCH_APARTMENT_PLUGIN T S1 APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491
50 LIGHTING_PLUGIN_TS2 LTG_SCH_APARTMENT_PLUGIN T S2 APARTMENT 88.25 2.5 85.491 0.969 34.197 0.000 0.600 0.200 0.200 1.000 LightsPlugIn 0.000 85.491


ElectricEquipment Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Equipment Level {W} Equipment/Floor Area {W/m2} Equipment per person {W/person} Fraction Latent Fraction Radiant Fraction Lost Fraction Convected End-Use SubCategory Nominal Minimum Equipment Level {W} Nominal Maximum Equipment Level {W}
1 ELEVATOR_LIFT_RUNNING ELEVATOR_RUNNING_SCH G CORRIDOR 77.66 4.2 25598.000 329.619 6123.923 0.000 0.000 0.950 5.000E-002 ElevatorLift 0.000 1725.049
2 ELEVATOR_LIFT_STANDBY ELEVATOR_STANDBY_SCH G CORRIDOR 77.66 4.2 800.000 10.301 191.388 0.000 0.000 0.950 5.000E-002 ElevatorLift 593.576 800.000
3 ELEVATORS_LIGHTS_FAN ELEV_LIGHT_FAN_SCH_ADD_DF G CORRIDOR 77.66 4.2 52.660 0.678 12.598 0.000 0.000 0.950 5.000E-002 ElevatorLightsFan 2.633 26.330
4 PLUG_GSW EQP_APT_SCH G SW APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
5 PLUG_GNW EQP_APT_SCH G NW APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
6 PLUG_OFFICE EQP_OFF_SCH OFFICE 88.25 4.7 588.623 6.670 123.933 0.000 0.500 0.000 0.500 MiscPlug 0.000 588.623
7 PLUG_GNE EQP_APT_SCH G NE APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
8 PLUG_GN1 EQP_APT_SCH G N1 APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
9 PLUG_GN2 EQP_APT_SCH G N2 APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
10 PLUG_GS1 EQP_APT_SCH G S1 APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
11 PLUG_GS2 EQP_APT_SCH G S2 APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
12 PLUG_MSW EQP_APT_SCH M SW APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
13 PLUG_MNW EQP_APT_SCH M NW APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
14 PLUG_MSE EQP_APT_SCH M SE APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
15 PLUG_MNE EQP_APT_SCH M NE APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
16 PLUG_MN1 EQP_APT_SCH M N1 APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
17 PLUG_MN2 EQP_APT_SCH M N2 APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
18 PLUG_MS1 EQP_APT_SCH M S1 APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
19 PLUG_MS2 EQP_APT_SCH M S2 APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
20 PLUG_TSW EQP_APT_SCH T SW APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
21 PLUG_TNW EQP_APT_SCH T NW APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
22 PLUG_TSE EQP_APT_SCH T SE APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
23 PLUG_TNE EQP_APT_SCH T NE APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
24 PLUG_TN1 EQP_APT_SCH T N1 APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
25 PLUG_TN2 EQP_APT_SCH T N2 APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
26 PLUG_TS1 EQP_APT_SCH T S1 APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623
27 PLUG_TS2 EQP_APT_SCH T S2 APARTMENT 88.25 2.5 588.623 6.670 235.449 0.000 0.500 0.000 0.500 MiscPlug 223.677 588.623


Shadowing/Sun Position Calculations Annual Simulations

Shading Calculation Method Shading Calculation Update Frequency Method Shading Calculation Update Frequency {days} Maximum Figures in Shadow Overlap Calculations {} Polygon Clipping Algorithm Pixel Counting Resolution Sky Diffuse Modeling Algorithm Output External Shading Calculation Results Disable Self-Shading Within Shading Zone Groups Disable Self-Shading From Shading Zone Groups to Other Zones
1 PolygonClipping Periodic 20 15000 SutherlandHodgman 512 SimpleSkyDiffuseModeling No No No


Water Heater Information

Type Name Volume {m3} Maximum Capacity {W} Standard Rated Recovery Efficiency Standard Rated Energy Factor
1 WaterHeater:Mixed SWHSYS1 WATER HEATER 0.9460 53912.0 11.449 0.4600


Surface Convection Parameters

Surface Name Outside Model Assignment Outside Area [m2] Outside Perimeter [m] Outside Height [m] Inside Model Assignment Inside Height [m] Inside Perimeter Envelope [m] Inside Hydraulic Diameter [m] Window Wall Ratio Window Location Near Radiant {Yes/No} Has Active HVAC {Yes/No}
1 G SWALL SWA 0 423.60 117.04 12.19 0 3.05 19.20 9.19 0.20 3 No No
2 GWINDOW1 S SWA 0 423.60 117.04 12.19 0 3.05 19.20 9.19 0.20 2 No No
3 G WWALL SWA 0 154.67 58.21 12.19 0 3.05 19.20 9.19 0.20 3 No No
4 GWINDOW1 W SWA 0 154.67 58.21 12.19 0 3.05 19.20 9.19 0.20 2 No No
5 G NIWALL SWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
6 G EIWALL SWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
7 G GFLOOR SWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
8 G CEILIN SWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
9 G INTERNALMASS SWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
10 G NWALL NWA 0 423.60 123.02 12.19 0 3.05 19.20 9.19 0.20 3 No No
11 GWINDOW1 N NWA 0 423.60 123.02 12.19 0 3.05 19.20 9.19 0.20 2 No No
12 G WWALL NWA 0 154.67 58.21 12.19 0 3.05 19.20 9.19 0.20 3 No No
13 GWINDOW1 W NWA 0 154.67 58.21 12.19 0 3.05 19.20 9.19 0.20 2 No No
14 G SIWALL NWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
15 G EIWALL NWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
16 G GFLOOR NWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
17 G CEILIN NWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
18 G INTERNALMASS NWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
19 G SWALL SEA 0 423.60 117.04 12.19 0 3.05 19.20 9.19 0.20 3 No No
20 GWINDOW1 S SEA 0 423.60 117.04 12.19 0 3.05 19.20 9.19 0.20 2 No No
21 G EWALL SEA 0 154.67 123.02 12.19 0 3.05 19.20 9.19 0.20 3 No No
22 GWINDOW1 E SEA 0 154.67 123.02 12.19 0 3.05 19.20 9.19 0.20 2 No No
23 G NIWALL SEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
24 iz-G EIWALL S2A 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
25 G GFLOOR SEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
26 G CEILIN SEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
27 G INTERNALMASS SEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
28 G NWALL NEA 0 423.60 123.02 12.19 0 3.05 19.20 9.19 0.20 3 No No
29 GWINDOW1 N NEA 0 423.60 123.02 12.19 0 3.05 19.20 9.19 0.20 2 No No
30 G EWALL NEA 0 154.67 123.02 12.19 0 3.05 19.20 9.19 0.20 3 No No
31 GWINDOW1 E NEA 0 154.67 123.02 12.19 0 3.05 19.20 9.19 0.20 2 No No
32 G SIWALL NEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
33 iz-G EIWALL N2A 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
34 G GFLOOR NEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
35 G CEILIN NEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
36 G INTERNALMASS NEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
37 G NWALL N1A 0 423.60 123.02 12.19 0 3.05 11.58 9.19 0.20 3 No No
38 GWINDOW1 N N1A 0 423.60 123.02 12.19 0 3.05 11.58 9.19 0.20 2 No No
39 G SIWALL N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
40 G EIWALL N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
41 iz-G EIWALL NWA 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
42 G GFLOOR N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
43 G CEILIN N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
44 G INTERNALMASS N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
45 G NWALL N2A 0 423.60 123.02 12.19 0 3.05 11.58 9.19 0.20 3 No No
46 GWINDOW1 N N2A 0 423.60 123.02 12.19 0 3.05 11.58 9.19 0.20 2 No No
47 G SIWALL N2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
48 G EIWALL N2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
49 iz-G EIWALL N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
50 G GFLOOR N2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
51 G CEILIN N2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
52 G INTERNALMASS N2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
53 G SWALL S1A 0 423.60 117.04 12.19 0 3.05 11.58 9.19 0.20 3 No No
54 GWINDOW1 S S1A 0 423.60 117.04 12.19 0 3.05 11.58 9.19 0.20 2 No No
55 G NIWALL S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
56 G EIWALL S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
57 iz-G EIWALL SWA 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
58 G GFLOOR S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
59 G CEILIN S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
60 G INTERNALMASS S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
61 G SWALL S2A 0 423.60 117.04 12.19 0 3.05 11.58 9.19 0.20 3 No No
62 GWINDOW1 S S2A 0 423.60 117.04 12.19 0 3.05 11.58 9.19 0.20 2 No No
63 G NIWALL S2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
64 G EIWALL S2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
65 iz-G EIWALL S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
66 G GFLOOR S2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
67 G CEILIN S2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
68 G INTERNALMASS S2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
69 M WWALL SWA 0 154.67 58.21 12.19 0 3.05 19.20 9.19 0.20 3 No No
70 MWINDOW1 W SWA 0 154.67 58.21 12.19 0 3.05 19.20 9.19 0.20 2 No No
71 M SWALL SWA 0 423.60 117.04 12.19 0 3.05 19.20 9.19 0.20 3 No No
72 MWINDOW1 S SWA 0 423.60 117.04 12.19 0 3.05 19.20 9.19 0.20 2 No No
73 M NIWALL SWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
74 M EIWALL SWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
75 M GFLOOR SWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
76 M CEILIN SWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
77 M INTERNALMASS SWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
78 M NWALL NWA 0 423.60 123.02 12.19 0 3.05 19.20 9.19 0.20 3 No No
79 MWINDOW1 N NWA 0 423.60 123.02 12.19 0 3.05 19.20 9.19 0.20 2 No No
80 M WWALL NWA 0 154.67 58.21 12.19 0 3.05 19.20 9.19 0.20 3 No No
81 MWINDOW1 W NWA 0 154.67 58.21 12.19 0 3.05 19.20 9.19 0.20 2 No No
82 M SIWALL NWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
83 M EIWALL NWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
84 M GFLOOR NWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
85 M CEILIN NWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
86 M INTERNALMASS NWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
87 M EWALL SEA 0 154.67 123.02 12.19 0 3.05 19.20 9.19 0.20 3 No No
88 MWINDOW1 E SEA 0 154.67 123.02 12.19 0 3.05 19.20 9.19 0.20 2 No No
89 M SWALL SEA 0 423.60 117.04 12.19 0 3.05 19.20 9.19 0.20 3 No No
90 MWINDOW1 S SEA 0 423.60 117.04 12.19 0 3.05 19.20 9.19 0.20 2 No No
91 M NIWALL SEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
92 iz-M EIWALL S2A 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
93 M GFLOOR SEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
94 M CEILIN SEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
95 M INTERNALMASS SEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
96 M NWALL NEA 0 423.60 123.02 12.19 0 3.05 19.20 9.19 0.20 3 No No
97 MWINDOW1 N NEA 0 423.60 123.02 12.19 0 3.05 19.20 9.19 0.20 2 No No
98 M EWALL NEA 0 154.67 123.02 12.19 0 3.05 19.20 9.19 0.20 3 No No
99 MWINDOW1 E NEA 0 154.67 123.02 12.19 0 3.05 19.20 9.19 0.20 2 No No
100 M SIWALL NEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
101 iz-M EIWALL N2A 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
102 M GFLOOR NEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
103 M CEILIN NEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
104 M INTERNALMASS NEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
105 M NWALL N1A 0 423.60 123.02 12.19 0 3.05 11.58 9.19 0.20 3 No No
106 MWINDOW1 N N1A 0 423.60 123.02 12.19 0 3.05 11.58 9.19 0.20 2 No No
107 M SIWALL N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
108 M EIWALL N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
109 iz-M EIWALL NWA 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
110 M GFLOOR N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
111 M CEILIN N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
112 M INTERNALMASS N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
113 M NWALL N2A 0 423.60 123.02 12.19 0 3.05 11.58 9.19 0.20 3 No No
114 MWINDOW1 N N2A 0 423.60 123.02 12.19 0 3.05 11.58 9.19 0.20 2 No No
115 M SIWALL N2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
116 M EIWALL N2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
117 iz-M EIWALL N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
118 M GFLOOR N2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
119 M CEILIN N2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
120 M INTERNALMASS N2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
121 M SWALL S1A 0 423.60 117.04 12.19 0 3.05 11.58 9.19 0.20 3 No No
122 MWINDOW1 S S1A 0 423.60 117.04 12.19 0 3.05 11.58 9.19 0.20 2 No No
123 M NIWALL S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
124 M EIWALL S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
125 iz-M EIWALL SWA 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
126 M GFLOOR S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
127 M CEILIN S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
128 M INTERNALMASS S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
129 M SWALL S2A 0 423.60 117.04 12.19 0 3.05 11.58 9.19 0.20 3 No No
130 MWINDOW1 S S2A 0 423.60 117.04 12.19 0 3.05 11.58 9.19 0.20 2 No No
131 M NIWALL S2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
132 M EIWALL S2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
133 iz-M EIWALL S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
134 M GFLOOR S2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
135 M CEILIN S2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
136 M INTERNALMASS S2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
137 T WWALL SWA 0 154.67 58.21 12.19 0 3.05 19.20 9.19 0.20 3 No No
138 TWINDOW1 W SWA 0 154.67 58.21 12.19 0 3.05 19.20 9.19 0.20 2 No No
139 T SWALL SWA 0 423.60 117.04 12.19 0 3.05 19.20 9.19 0.20 3 No No
140 TWINDOW1 S SWA 0 423.60 117.04 12.19 0 3.05 19.20 9.19 0.20 2 No No
141 T NIWALL SWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
142 T EIWALL SWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
143 T GFLOOR SWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
144 T ROOF SWA 0 783.65 155.90 0.00 0 3.05 19.20 9.19 0.20 0 No No
145 T INTERNALMASS SWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
146 T NWALL NWA 0 423.60 123.02 12.19 0 3.05 19.20 9.19 0.20 3 No No
147 TWINDOW1 N NWA 0 423.60 123.02 12.19 0 3.05 19.20 9.19 0.20 2 No No
148 T WWALL NWA 0 154.67 58.21 12.19 0 3.05 19.20 9.19 0.20 3 No No
149 TWINDOW1 W NWA 0 154.67 58.21 12.19 0 3.05 19.20 9.19 0.20 2 No No
150 T SIWALL NWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
151 T EIWALL NWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
152 T GFLOOR NWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
153 T ROOF NWA 0 783.65 155.90 0.00 0 3.05 19.20 9.19 0.20 0 No No
154 T INTERNALMASS NWA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
155 T EWALL SEA 0 154.67 123.02 12.19 0 3.05 19.20 9.19 0.20 3 No No
156 TWINDOW1 E SEA 0 154.67 123.02 12.19 0 3.05 19.20 9.19 0.20 2 No No
157 T SWALL SEA 0 423.60 117.04 12.19 0 3.05 19.20 9.19 0.20 3 No No
158 TWINDOW1 S SEA 0 423.60 117.04 12.19 0 3.05 19.20 9.19 0.20 2 No No
159 T NIWALL SEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
160 iz-T EIWALL S2A 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
161 T GFLOOR SEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
162 T ROOF SEA 0 783.65 155.90 0.00 0 3.05 19.20 9.19 0.20 0 No No
163 T INTERNALMASS SEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
164 T NWALL NEA 0 423.60 123.02 12.19 0 3.05 19.20 9.19 0.20 3 No No
165 TWINDOW1 N NEA 0 423.60 123.02 12.19 0 3.05 19.20 9.19 0.20 2 No No
166 T EWALL NEA 0 154.67 123.02 12.19 0 3.05 19.20 9.19 0.20 3 No No
167 TWINDOW1 E NEA 0 154.67 123.02 12.19 0 3.05 19.20 9.19 0.20 2 No No
168 T SIWALL NEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
169 iz-T EIWALL N2A 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
170 T GFLOOR NEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
171 T ROOF NEA 0 783.65 155.90 0.00 0 3.05 19.20 9.19 0.20 0 No No
172 T INTERNALMASS NEA 0 0.00 0.00 0.00 0 3.05 19.20 9.19 0.20 0 No No
173 T NWALL N1A 0 423.60 123.02 12.19 0 3.05 11.58 9.19 0.20 3 No No
174 TWINDOW1 N N1A 0 423.60 123.02 12.19 0 3.05 11.58 9.19 0.20 2 No No
175 T SIWALL N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
176 T EIWALL N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
177 iz-T EIWALL NWA 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
178 T GFLOOR N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
179 T ROOF N1A 0 783.65 155.90 0.00 0 3.05 11.58 9.19 0.20 0 No No
180 T INTERNALMASS N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
181 T NWALL N2A 0 423.60 123.02 12.19 0 3.05 11.58 9.19 0.20 3 No No
182 TWINDOW1 N N2A 0 423.60 123.02 12.19 0 3.05 11.58 9.19 0.20 2 No No
183 T SIWALL N2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
184 T EIWALL N2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
185 iz-T EIWALL N1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
186 T GFLOOR N2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
187 T ROOF N2A 0 783.65 155.90 0.00 0 3.05 11.58 9.19 0.20 0 No No
188 T INTERNALMASS N2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
189 T SWALL S1A 0 423.60 117.04 12.19 0 3.05 11.58 9.19 0.20 3 No No
190 TWINDOW1 S S1A 0 423.60 117.04 12.19 0 3.05 11.58 9.19 0.20 2 No No
191 T NIWALL S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
192 T EIWALL S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
193 iz-T EIWALL SWA 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
194 T GFLOOR S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
195 T ROOF S1A 0 783.65 155.90 0.00 0 3.05 11.58 9.19 0.20 0 No No
196 T INTERNALMASS S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
197 T SWALL S2A 0 423.60 117.04 12.19 0 3.05 11.58 9.19 0.20 3 No No
198 TWINDOW1 S S2A 0 423.60 117.04 12.19 0 3.05 11.58 9.19 0.20 2 No No
199 T NIWALL S2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
200 T EIWALL S2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
201 iz-T EIWALL S1A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
202 T GFLOOR S2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
203 T ROOF S2A 0 783.65 155.90 0.00 0 3.05 11.58 9.19 0.20 0 No No
204 T INTERNALMASS S2A 0 0.00 0.00 0.00 0 3.05 11.58 9.19 0.20 0 No No
205 T WWALL C 0 154.67 58.21 12.19 0 3.05 3.35 3.24 0.11 3 No No
206 T EWALL C 0 154.67 123.02 12.19 0 3.05 3.35 3.24 0.11 3 No No
207 TWINDOW14 0 154.67 123.02 12.19 0 3.05 3.35 3.24 0.11 2 No No
208 iz-T NIWALL SWA 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
209 iz-T NIWALL S1A 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
210 iz-T NIWALL S2A 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
211 iz-T NIWALL SEA 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
212 iz-T SIWALL NWA 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
213 iz-T SIWALL N1A 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
214 iz-T SIWALL N2A 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
215 iz-T SIWALL NEA 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
216 T FLOOR C 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
217 T ROOF C 0 783.65 155.90 0.00 0 3.05 3.35 3.24 0.11 0 No No
218 G WWALL C 0 154.67 58.21 12.19 0 3.05 3.35 3.24 0.32 4 No No
219 G EWALL C 0 154.67 123.02 12.19 0 3.05 3.35 3.24 0.32 4 No No
220 ENTRANCE DOOR 0 154.67 123.02 12.19 0 3.05 3.35 3.24 0.32 1 No No
221 iz-G NIWALL SWA 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.32 0 No No
222 iz-G NIWALL S1A 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.32 0 No No
223 iz-G NIWALL S2A 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.32 0 No No
224 iz-G NIWALL SEA 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.32 0 No No
225 iz-G SIWALL NWA 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.32 0 No No
226 iz-G SIWALL N1A 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.32 0 No No
227 iz-G SIWALL N2A 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.32 0 No No
228 iz-G SIWALL NEA 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.32 0 No No
229 G FLOOR C 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.32 0 No No
230 G CEILING C 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.32 0 No No
231 M WWALL C 0 154.67 58.21 12.19 0 3.05 3.35 3.24 0.11 4 No No
232 M EWALL C 0 154.67 123.02 12.19 0 3.05 3.35 3.24 0.11 3 No No
233 MWINDOW14 0 154.67 123.02 12.19 0 3.05 3.35 3.24 0.11 2 No No
234 iz-M NIWALL SWA 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
235 iz-M NIWALL S1A 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
236 iz-M NIWALL S2A 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
237 iz-M NIWALL SEA 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
238 iz-M SIWALL NWA 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
239 iz-M SIWALL N1A 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
240 iz-M SIWALL N2A 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
241 iz-M SIWALL NEA 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
242 M FLOOR C 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No
243 M CEILING C 0 0.00 0.00 0.00 0 3.05 3.35 3.24 0.11 0 No No


ZoneInfiltration Airflow Stats Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Design Volume Flow Rate {m3/s} Volume Flow Rate/Floor Area {m3/s-m2} Volume Flow Rate/Exterior Surface Area {m3/s-m2} ACH - Air Changes per Hour Equation A - Constant Term Coefficient {} Equation B - Temperature Term Coefficient {1/C} Equation C - Velocity Term Coefficient {s/m} Equation D - Velocity Squared Term Coefficient {s2/m2}
1 INFIL_GSW INF_APT_SCH G SW APARTMENT 88.25 2.5 1.500E-002 1.700E-004 2.563E-004 0.201 0.000 0.000 0.224 0.000
2 INFIL_GNW INF_APT_SCH G NW APARTMENT 88.25 2.5 1.500E-002 1.700E-004 2.563E-004 0.201 0.000 0.000 0.224 0.000
3 INFIL_OFFICE INF_OFF_SCH OFFICE 88.25 4.7 1.500E-002 1.700E-004 2.563E-004 0.201 0.000 0.000 0.224 0.000
4 INFIL_GNE INF_APT_SCH G NE APARTMENT 88.25 2.5 1.500E-002 1.700E-004 2.563E-004 0.201 0.000 0.000 0.224 0.000
5 INFIL_GN1 INF_APT_SCH G N1 APARTMENT 88.25 2.5 9.048E-003 1.025E-004 2.563E-004 0.121 0.000 0.000 0.224 0.000
6 INFIL_GN2 INF_APT_SCH G N2 APARTMENT 88.25 2.5 9.048E-003 1.025E-004 2.563E-004 0.121 0.000 0.000 0.224 0.000
7 INFIL_GS1 INF_APT_SCH G S1 APARTMENT 88.25 2.5 9.048E-003 1.025E-004 2.563E-004 0.121 0.000 0.000 0.224 0.000
8 INFIL_GS2 INF_APT_SCH G S2 APARTMENT 88.25 2.5 9.048E-003 1.025E-004 2.563E-004 0.121 0.000 0.000 0.224 0.000
9 INFIL_MSW INF_APT_SCH M SW APARTMENT 88.25 2.5 1.500E-002 1.700E-004 2.563E-004 0.201 0.000 0.000 0.224 0.000
10 INFIL_MNW INF_APT_SCH M NW APARTMENT 88.25 2.5 1.500E-002 1.700E-004 2.563E-004 0.201 0.000 0.000 0.224 0.000
11 INFIL_MSE INF_APT_SCH M SE APARTMENT 88.25 2.5 1.500E-002 1.700E-004 2.563E-004 0.201 0.000 0.000 0.224 0.000
12 INFIL_MNE INF_APT_SCH M NE APARTMENT 88.25 2.5 1.500E-002 1.700E-004 2.563E-004 0.201 0.000 0.000 0.224 0.000
13 INFIL_MN1 INF_APT_SCH M N1 APARTMENT 88.25 2.5 9.048E-003 1.025E-004 2.563E-004 0.121 0.000 0.000 0.224 0.000
14 INFIL_MN2 INF_APT_SCH M N2 APARTMENT 88.25 2.5 9.048E-003 1.025E-004 2.563E-004 0.121 0.000 0.000 0.224 0.000
15 INFIL_MS1 INF_APT_SCH M S1 APARTMENT 88.25 2.5 9.048E-003 1.025E-004 2.563E-004 0.121 0.000 0.000 0.224 0.000
16 INFIL_MS2 INF_APT_SCH M S2 APARTMENT 88.25 2.5 9.048E-003 1.025E-004 2.563E-004 0.121 0.000 0.000 0.224 0.000
17 INFIL_SW INF_APT_SCH T SW APARTMENT 88.25 2.5 1.500E-002 1.700E-004 1.022E-004 0.201 0.000 0.000 0.224 0.000
18 INFIL_NW INF_APT_SCH T NW APARTMENT 88.25 2.5 1.500E-002 1.700E-004 1.022E-004 0.201 0.000 0.000 0.224 0.000
19 INFIL_SE INF_APT_SCH T SE APARTMENT 88.25 2.5 1.500E-002 1.700E-004 1.022E-004 0.201 0.000 0.000 0.224 0.000
20 INFIL_NE INF_APT_SCH T NE APARTMENT 88.25 2.5 1.500E-002 1.700E-004 1.022E-004 0.201 0.000 0.000 0.224 0.000
21 INFIL_TN1 INF_APT_SCH T N1 APARTMENT 88.25 2.5 9.048E-003 1.025E-004 7.323E-005 0.121 0.000 0.000 0.224 0.000
22 INFIL_TN2 INF_APT_SCH T N2 APARTMENT 88.25 2.5 9.048E-003 1.025E-004 7.323E-005 0.121 0.000 0.000 0.224 0.000
23 INFIL_TS1 INF_APT_SCH T S1 APARTMENT 88.25 2.5 9.048E-003 1.025E-004 7.323E-005 0.121 0.000 0.000 0.224 0.000
24 INFIL_TS2 INF_APT_SCH T S2 APARTMENT 88.25 2.5 9.048E-003 1.025E-004 7.323E-005 0.121 0.000 0.000 0.224 0.000
25 INFIL_GC INF_COR_SCH G CORRIDOR 77.66 4.2 2.619E-003 3.372E-005 2.563E-004 3.983E-002 0.000 0.000 0.224 0.000
26 DOOR_INFIL_GC INFIL_DOOR_OPENING_SCH G CORRIDOR 77.66 4.2 0.521 6.703E-003 5.094E-002 7.917 1.000 0.000 0.000 0.000
27 INFIL_MC INF_COR_SCH M CORRIDOR 77.66 4.2 2.619E-003 3.372E-005 2.563E-004 3.983E-002 0.000 0.000 0.224 0.000
28 INFIL_TC INF_COR_SCH T CORRIDOR 77.66 4.2 2.619E-003 3.372E-005 2.980E-005 3.983E-002 0.000 0.000 0.224 0.000


ZoneVentilation Airflow Stats Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Design Volume Flow Rate {m3/s} Volume Flow Rate/Floor Area {m3/s-m2} Volume Flow Rate/person Area {m3/s-person} ACH - Air Changes per Hour Fan Type {Exhaust;Intake;Natural} Fan Pressure Rise {Pa} Fan Efficiency {} Equation A - Constant Term Coefficient {} Equation B - Temperature Term Coefficient {1/C} Equation C - Velocity Term Coefficient {s/m} Equation D - Velocity Squared Term Coefficient {s2/m2} Minimum Indoor Temperature{C}/Schedule Maximum Indoor Temperature{C}/Schedule Delta Temperature{C}/Schedule Minimum Outdoor Temperature{C}/Schedule Maximum Outdoor Temperature{C}/Schedule Maximum WindSpeed{m/s}
1 G SW APARTMENT SLIDING DOOR VENTILATION Constant-0.0 G SW APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
2 G NW APARTMENT SLIDING DOOR VENTILATION Constant-0.0 G NW APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
3 G NE APARTMENT SLIDING DOOR VENTILATION Constant-0.0 G NE APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
4 G N1 APARTMENT SLIDING DOOR VENTILATION Constant-0.0 G N1 APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
5 G N2 APARTMENT SLIDING DOOR VENTILATION Constant-0.0 G N2 APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
6 G S1 APARTMENT SLIDING DOOR VENTILATION Constant-0.0 G S1 APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
7 G S2 APARTMENT SLIDING DOOR VENTILATION Constant-0.0 G S2 APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
8 M SW APARTMENT SLIDING DOOR VENTILATION Constant-0.0 M SW APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
9 M NW APARTMENT SLIDING DOOR VENTILATION Constant-0.0 M NW APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
10 M SE APARTMENT SLIDING DOOR VENTILATION Constant-0.0 M SE APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
11 M NE APARTMENT SLIDING DOOR VENTILATION Constant-0.0 M NE APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
12 M N1 APARTMENT SLIDING DOOR VENTILATION Constant-0.0 M N1 APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
13 M N2 APARTMENT SLIDING DOOR VENTILATION Constant-0.0 M N2 APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
14 M S1 APARTMENT SLIDING DOOR VENTILATION Constant-0.0 M S1 APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
15 M S2 APARTMENT SLIDING DOOR VENTILATION Constant-0.0 M S2 APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
16 T SW APARTMENT SLIDING DOOR VENTILATION Constant-0.0 T SW APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
17 T NW APARTMENT SLIDING DOOR VENTILATION Constant-0.0 T NW APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
18 T SE APARTMENT SLIDING DOOR VENTILATION Constant-0.0 T SE APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
19 T NE APARTMENT SLIDING DOOR VENTILATION Constant-0.0 T NE APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
20 T N1 APARTMENT SLIDING DOOR VENTILATION Constant-0.0 T N1 APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
21 T N2 APARTMENT SLIDING DOOR VENTILATION Constant-0.0 T N2 APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
22 T S1 APARTMENT SLIDING DOOR VENTILATION Constant-0.0 T S1 APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00
23 T S2 APARTMENT SLIDING DOOR VENTILATION Constant-0.0 T S2 APARTMENT 88.25 2.5 0.000 0.000 0.000 0.000 Natural 0.000 0.0 0.000 0.000 0.000 0.000 18.89 25.56 -100.00 15.56 23.89 40.00


AirFlow Model

Simple
1 Simple


RoomAir Model

Zone Name Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined
1 G SW APARTMENT Mixing/Well-Stirred
2 G NW APARTMENT Mixing/Well-Stirred
3 OFFICE Mixing/Well-Stirred
4 G NE APARTMENT Mixing/Well-Stirred
5 G N1 APARTMENT Mixing/Well-Stirred
6 G N2 APARTMENT Mixing/Well-Stirred
7 G S1 APARTMENT Mixing/Well-Stirred
8 G S2 APARTMENT Mixing/Well-Stirred
9 M SW APARTMENT Mixing/Well-Stirred
10 M NW APARTMENT Mixing/Well-Stirred
11 M SE APARTMENT Mixing/Well-Stirred
12 M NE APARTMENT Mixing/Well-Stirred
13 M N1 APARTMENT Mixing/Well-Stirred
14 M N2 APARTMENT Mixing/Well-Stirred
15 M S1 APARTMENT Mixing/Well-Stirred
16 M S2 APARTMENT Mixing/Well-Stirred
17 T SW APARTMENT Mixing/Well-Stirred
18 T NW APARTMENT Mixing/Well-Stirred
19 T SE APARTMENT Mixing/Well-Stirred
20 T NE APARTMENT Mixing/Well-Stirred
21 T N1 APARTMENT Mixing/Well-Stirred
22 T N2 APARTMENT Mixing/Well-Stirred
23 T S1 APARTMENT Mixing/Well-Stirred
24 T S2 APARTMENT Mixing/Well-Stirred
25 T CORRIDOR Mixing/Well-Stirred
26 G CORRIDOR Mixing/Well-Stirred
27 M CORRIDOR Mixing/Well-Stirred


AirflowNetwork Model:Control

No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation
1 NoMultizoneOrDistribution


Zone Volume Capacitance Multiplier

Sensible Heat Capacity Multiplier Moisture Capacity Multiplier Carbon Dioxide Capacity Multiplier Generic Contaminant Capacity Multiplier
1 1.000 1.000 1.000 1.000


Load Timesteps in Zone Design Calculation Averaging Window

Value
1 6


Heating Sizing Factor Information

Sizing Factor ID Value
1 Global 1.2000
2 Zone G SW APARTMENT 1.2000
3 Zone G NW APARTMENT 1.2000
4 Zone OFFICE 1.2000
5 Zone G NE APARTMENT 1.2000
6 Zone G N1 APARTMENT 1.2000
7 Zone G N2 APARTMENT 1.2000
8 Zone G S1 APARTMENT 1.2000
9 Zone G S2 APARTMENT 1.2000
10 Zone M SW APARTMENT 1.2000
11 Zone M NW APARTMENT 1.2000
12 Zone M SE APARTMENT 1.2000
13 Zone M NE APARTMENT 1.2000
14 Zone M N1 APARTMENT 1.2000
15 Zone M N2 APARTMENT 1.2000
16 Zone M S1 APARTMENT 1.2000
17 Zone M S2 APARTMENT 1.2000
18 Zone T SW APARTMENT 1.2000
19 Zone T NW APARTMENT 1.2000
20 Zone T SE APARTMENT 1.2000
21 Zone T NE APARTMENT 1.2000
22 Zone T N1 APARTMENT 1.2000
23 Zone T N2 APARTMENT 1.2000
24 Zone T S1 APARTMENT 1.2000
25 Zone T S2 APARTMENT 1.2000


Cooling Sizing Factor Information

Sizing Factor ID Value
1 Global 1.2000
2 Zone G SW APARTMENT 1.2000
3 Zone G NW APARTMENT 1.2000
4 Zone OFFICE 1.2000
5 Zone G NE APARTMENT 1.2000
6 Zone G N1 APARTMENT 1.2000
7 Zone G N2 APARTMENT 1.2000
8 Zone G S1 APARTMENT 1.2000
9 Zone G S2 APARTMENT 1.2000
10 Zone M SW APARTMENT 1.2000
11 Zone M NW APARTMENT 1.2000
12 Zone M SE APARTMENT 1.2000
13 Zone M NE APARTMENT 1.2000
14 Zone M N1 APARTMENT 1.2000
15 Zone M N2 APARTMENT 1.2000
16 Zone M S1 APARTMENT 1.2000
17 Zone M S2 APARTMENT 1.2000
18 Zone T SW APARTMENT 1.2000
19 Zone T NW APARTMENT 1.2000
20 Zone T SE APARTMENT 1.2000
21 Zone T NE APARTMENT 1.2000
22 Zone T N1 APARTMENT 1.2000
23 Zone T N2 APARTMENT 1.2000
24 Zone T S1 APARTMENT 1.2000
25 Zone T S2 APARTMENT 1.2000


Zone Sizing Information

Zone Name Load Type Calc Des Load {W} User Des Load {W} Calc Des Air Flow Rate {m3/s} User Des Air Flow Rate {m3/s} Design Day Name Date/Time of Peak Temperature at Peak {C} Humidity Ratio at Peak {kgWater/kgDryAir} Floor Area {m2} # Occupants Calc Outdoor Air Flow Rate {m3/s} Calc DOAS Heat Addition Rate {W}
1 G SW APARTMENT Cooling 3665.94527 4399.13432 0.28495 0.34194 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 2.59546E-002 0.00000
2 G SW APARTMENT Heating 798.97171 958.76605 3.79220E-002 4.55064E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 0.50000 4.31558E-003 88.24927 2.50000 2.59546E-002 0.00000
3 G NW APARTMENT Cooling 3606.33721 4327.60465 0.28019 0.33623 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 2.59546E-002 0.00000
4 G NW APARTMENT Heating 672.59024 807.10829 3.19241E-002 3.83090E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 0.50000 4.31558E-003 88.24927 2.50000 2.59546E-002 0.00000
5 OFFICE Cooling 4217.88297 5061.45956 0.34087 0.40905 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 09:20:00 34.23867 5.62096E-003 88.24927 4.74953 3.81060E-002 0.00000
6 OFFICE Heating 1229.08463 1474.90155 5.83369E-002 7.00043E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 18:50:00 0.50000 4.31558E-003 88.24927 4.74953 3.81060E-002 0.00000
7 G NE APARTMENT Cooling 3355.40132 4026.48158 0.26032 0.31239 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 2.59546E-002 0.00000
8 G NE APARTMENT Heating 674.77637 809.73164 3.20279E-002 3.84335E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 0.50000 4.31558E-003 88.24927 2.50000 2.59546E-002 0.00000
9 G N1 APARTMENT Cooling 2889.44833 3467.33799 0.22322 0.26786 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 2.59546E-002 0.00000
10 G N1 APARTMENT Heating 335.29222 402.35067 1.59145E-002 2.59546E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 0.50000 4.31558E-003 88.24927 2.50000 2.59546E-002 0.00000
11 G N2 APARTMENT Cooling 2884.99410 3461.99292 0.22286 0.26744 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 2.59546E-002 0.00000
12 G N2 APARTMENT Heating 335.36491 402.43790 1.59180E-002 2.59546E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 0.50000 4.31558E-003 88.24927 2.50000 2.59546E-002 0.00000
13 G S1 APARTMENT Cooling 2944.64494 3533.57392 0.22763 0.27316 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 2.59546E-002 0.00000
14 G S1 APARTMENT Heating 461.92119 554.30543 2.19244E-002 2.63093E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 0.50000 4.31558E-003 88.24927 2.50000 2.59546E-002 0.00000
15 G S2 APARTMENT Cooling 3005.44089 3606.52907 0.23246 0.27895 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 2.59546E-002 0.00000
16 G S2 APARTMENT Heating 473.59260 568.31112 2.24784E-002 2.69741E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 0.50000 4.31558E-003 88.24927 2.50000 2.59546E-002 0.00000
17 M SW APARTMENT Cooling 8319.58444 9983.50132 0.64875 0.77850 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 5.19091E-002 0.00000
18 M SW APARTMENT Heating 1819.81057 2183.77269 8.63743E-002 0.10365 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 0.50000 4.31558E-003 88.24927 2.50000 5.19091E-002 0.00000
19 M NW APARTMENT Cooling 8207.16204 9848.59444 0.63979 0.76775 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 5.19091E-002 0.00000
20 M NW APARTMENT Heating 1530.38337 1836.46004 7.26385E-002 8.71662E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 0.50000 4.31558E-003 88.24927 2.50000 5.19091E-002 0.00000
21 M SE APARTMENT Cooling 7655.16581 9186.19897 0.59576 0.71492 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 5.19091E-002 0.00000
22 M SE APARTMENT Heating 1825.16072 2190.19287 8.66282E-002 0.10395 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 0.50000 4.31558E-003 88.24927 2.50000 5.19091E-002 0.00000
23 M NE APARTMENT Cooling 7544.72397 9053.66876 0.58693 0.70431 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 5.19091E-002 0.00000
24 M NE APARTMENT Heating 1535.81601 1842.97922 7.28964E-002 8.74756E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 0.50000 4.31558E-003 88.24927 2.50000 5.19091E-002 0.00000
25 M N1 APARTMENT Cooling 6492.56619 7791.07943 0.50324 0.60388 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 5.19091E-002 0.00000
26 M N1 APARTMENT Heating 679.23281 815.07937 3.22394E-002 5.19091E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 0.50000 4.31558E-003 88.24927 2.50000 5.19091E-002 0.00000
27 M N2 APARTMENT Cooling 6481.32947 7777.59536 0.50235 0.60281 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 5.19091E-002 0.00000
28 M N2 APARTMENT Heating 679.38530 815.26236 3.22467E-002 5.19091E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 0.50000 4.31558E-003 88.24927 2.50000 5.19091E-002 0.00000
29 M S1 APARTMENT Cooling 6599.61001 7919.53201 0.51181 0.61417 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 5.19091E-002 0.00000
30 M S1 APARTMENT Heating 960.54361 1152.65233 4.55908E-002 5.47089E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 0.50000 4.31558E-003 88.24927 2.50000 5.19091E-002 0.00000
31 M S2 APARTMENT Cooling 6589.52119 7907.42542 0.51101 0.61321 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 5.19091E-002 0.00000
32 M S2 APARTMENT Heating 960.69250 1152.83100 4.55978E-002 5.47174E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 0.50000 4.31558E-003 88.24927 2.50000 5.19091E-002 0.00000
33 T SW APARTMENT Cooling 4799.35144 5759.22172 0.37494 0.44993 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 2.59546E-002 0.00000
34 T SW APARTMENT Heating 1628.80644 1954.56773 7.73083E-002 9.27699E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 0.50000 4.31558E-003 88.24927 2.50000 2.59546E-002 0.00000
35 T NW APARTMENT Cooling 4788.63339 5746.36007 0.37409 0.44890 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 2.59546E-002 0.00000
36 T NW APARTMENT Heating 1473.10445 1767.72535 6.99195E-002 8.39034E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 0.50000 4.31558E-003 88.24927 2.50000 2.59546E-002 0.00000
37 T SE APARTMENT Cooling 4307.86174 5169.43409 0.33594 0.40313 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 2.59546E-002 0.00000
38 T SE APARTMENT Heating 1631.87999 1958.25599 7.74542E-002 9.29450E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 0.50000 4.31558E-003 88.24927 2.50000 2.59546E-002 0.00000
39 T NE APARTMENT Cooling 4296.29536 5155.55444 0.33504 0.40204 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 2.59546E-002 0.00000
40 T NE APARTMENT Heating 1476.25668 1771.50802 7.00692E-002 8.40830E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 0.50000 4.31558E-003 88.24927 2.50000 2.59546E-002 0.00000
41 T N1 APARTMENT Cooling 3867.12579 4640.55095 0.30091 0.36109 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 2.59546E-002 0.00000
42 T N1 APARTMENT Heating 1003.21151 1203.85382 4.76168E-002 5.71402E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 0.50000 4.31558E-003 88.24927 2.50000 2.59546E-002 0.00000
43 T N2 APARTMENT Cooling 3851.93831 4622.32597 0.29970 0.35964 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 2.59546E-002 0.00000
44 T N2 APARTMENT Heating 1003.30828 1203.96994 4.76214E-002 5.71457E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 0.50000 4.31558E-003 88.24927 2.50000 2.59546E-002 0.00000
45 T S1 APARTMENT Cooling 3885.95904 4663.15085 0.30240 0.36288 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 2.59546E-002 0.00000
46 T S1 APARTMENT Heating 1159.53404 1391.44085 5.50355E-002 6.60425E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 0.50000 4.31558E-003 88.24927 2.50000 2.59546E-002 0.00000
47 T S2 APARTMENT Cooling 3870.81258 4644.97509 0.30120 0.36143 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 35.61300 5.62306E-003 88.24927 2.50000 2.59546E-002 0.00000
48 T S2 APARTMENT Heating 1159.62745 1391.55294 5.50399E-002 6.60479E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 0.50000 4.31558E-003 88.24927 2.50000 2.59546E-002 0.00000


System Sizing Information

System Name Load Type Peak Load Kind User Design Capacity Calc Des Air Flow Rate [m3/s] User Des Air Flow Rate [m3/s] Design Day Name Date/Time of Peak
1 SPLIT GSW Cooling Sensible 4552.54 0.34194 0.34194 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
2 SPLIT GSW Heating Sensible 1532.13 4.55064E-002 4.55064E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00
3 SPLIT GNW Cooling Sensible 4481.63 0.33623 0.33623 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
4 SPLIT GNW Heating Sensible 1382.69 3.83090E-002 3.83090E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00
5 SPLIT OFFICE Cooling Sensible 5420.50 0.40905 0.40905 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
6 SPLIT OFFICE Heating Sensible 2315.72 7.00043E-002 7.00043E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 18:50:00
7 SPLIT GNE Cooling Sensible 4184.74 0.31239 0.31239 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
8 SPLIT GNE Heating Sensible 1385.27 3.84335E-002 3.84335E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00
9 SPLIT GN1 Cooling Sensible 3630.59 0.26786 0.26786 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
10 SPLIT GN1 Heating Sensible 1126.19 2.59546E-002 2.59546E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00
11 SPLIT GN2 Cooling Sensible 3625.32 0.26744 0.26744 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
12 SPLIT GN2 Heating Sensible 1126.19 2.59546E-002 2.59546E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00
13 SPLIT GS1 Cooling Sensible 3695.98 0.27316 0.27316 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
14 SPLIT GS1 Heating Sensible 1133.56 2.63093E-002 2.63093E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00
15 SPLIT GS2 Cooling Sensible 3768.53 0.27895 0.27895 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
16 SPLIT GS2 Heating Sensible 1147.36 2.69741E-002 2.69741E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00
17 SPLIT MSW Cooling Sensible 10279.70 0.77850 0.77850 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
18 SPLIT MSW Heating Sensible 3326.61 0.10365 0.10365 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00
19 SPLIT MNW Cooling Sensible 10146.30 0.76775 0.76775 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
20 SPLIT MNW Heating Sensible 2984.38 8.71662E-002 8.71662E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00
21 SPLIT MSE Cooling Sensible 9490.35 0.71492 0.71492 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
22 SPLIT MSE Heating Sensible 3332.94 0.10395 0.10395 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00
23 SPLIT MNE Cooling Sensible 9358.88 0.70431 0.70431 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
24 SPLIT MNE Heating Sensible 2990.80 8.74756E-002 8.74756E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00
25 SPLIT MN1 Cooling Sensible 8110.82 0.60388 0.60388 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
26 SPLIT MN1 Heating Sensible 2252.39 5.19091E-002 5.19091E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 17:50:00
27 SPLIT MN2 Cooling Sensible 8097.50 0.60281 0.60281 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
28 SPLIT MN2 Heating Sensible 2252.39 5.19091E-002 5.19091E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00
29 SPLIT MS1 Cooling Sensible 8237.75 0.61417 0.61417 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
30 SPLIT MS1 Heating Sensible 2310.52 5.47089E-002 5.47089E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00
31 SPLIT MS2 Cooling Sensible 8225.79 0.61321 0.61321 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
32 SPLIT MS2 Heating Sensible 2310.69 5.47174E-002 5.47174E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00
33 SPLIT TSW Cooling Sensible 5895.75 0.44993 0.44993 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
34 SPLIT TSW Heating Sensible 2513.42 9.27699E-002 9.27699E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00
35 SPLIT TNW Cooling Sensible 5883.07 0.44890 0.44890 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
36 SPLIT TNW Heating Sensible 2329.31 8.39034E-002 8.39034E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00
37 SPLIT TSE Cooling Sensible 5314.24 0.40313 0.40313 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
38 SPLIT TSE Heating Sensible 2517.05 9.29450E-002 9.29450E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00
39 SPLIT TNE Cooling Sensible 5300.67 0.40204 0.40204 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
40 SPLIT TNE Heating Sensible 2333.04 8.40830E-002 8.40830E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00
41 SPLIT TN1 Cooling Sensible 4792.13 0.36109 0.36109 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
42 SPLIT TN1 Heating Sensible 1773.66 5.71402E-002 5.71402E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00
43 SPLIT TN2 Cooling Sensible 4774.12 0.35964 0.35964 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
44 SPLIT TN2 Heating Sensible 1773.77 5.71457E-002 5.71457E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00
45 SPLIT TS1 Cooling Sensible 4814.42 0.36288 0.36288 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
46 SPLIT TS1 Heating Sensible 1958.50 6.60425E-002 6.60425E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00
47 SPLIT TS2 Cooling Sensible 4796.46 0.36143 0.36143 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
48 SPLIT TS2 Heating Sensible 1958.61 6.60479E-002 6.60479E-002 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00


Component Sizing Information

Component Type Component Name Input Field Description Value
1 ZoneHVAC:EnergyRecoveryVentilator G SW APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 2.59546E-002
2 ZoneHVAC:EnergyRecoveryVentilator G SW APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 2.59546E-002
3 Fan:OnOff G SW APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
4 Fan:OnOff G SW APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
5 HeatExchanger:AirToAir:SensibleAndLatent G SW APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 2.59546E-002
6 AirTerminal:SingleDuct:ConstantVolume:NoReheat G SW APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.34194
7 ZoneHVAC:EnergyRecoveryVentilator G NW APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 2.59546E-002
8 ZoneHVAC:EnergyRecoveryVentilator G NW APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 2.59546E-002
9 Fan:OnOff G NW APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
10 Fan:OnOff G NW APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
11 HeatExchanger:AirToAir:SensibleAndLatent G NW APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 2.59546E-002
12 AirTerminal:SingleDuct:ConstantVolume:NoReheat G NW APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.33623
13 AirTerminal:SingleDuct:ConstantVolume:NoReheat OFFICE DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.40905
14 ZoneHVAC:EnergyRecoveryVentilator G NE APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 2.59546E-002
15 ZoneHVAC:EnergyRecoveryVentilator G NE APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 2.59546E-002
16 Fan:OnOff G NE APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
17 Fan:OnOff G NE APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
18 HeatExchanger:AirToAir:SensibleAndLatent G NE APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 2.59546E-002
19 AirTerminal:SingleDuct:ConstantVolume:NoReheat G NE APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.31239
20 ZoneHVAC:EnergyRecoveryVentilator G N1 APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 2.59546E-002
21 ZoneHVAC:EnergyRecoveryVentilator G N1 APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 2.59546E-002
22 Fan:OnOff G N1 APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
23 Fan:OnOff G N1 APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
24 HeatExchanger:AirToAir:SensibleAndLatent G N1 APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 2.59546E-002
25 AirTerminal:SingleDuct:ConstantVolume:NoReheat G N1 APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.26786
26 ZoneHVAC:EnergyRecoveryVentilator G N2 APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 2.59546E-002
27 ZoneHVAC:EnergyRecoveryVentilator G N2 APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 2.59546E-002
28 Fan:OnOff G N2 APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
29 Fan:OnOff G N2 APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
30 HeatExchanger:AirToAir:SensibleAndLatent G N2 APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 2.59546E-002
31 AirTerminal:SingleDuct:ConstantVolume:NoReheat G N2 APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.26744
32 ZoneHVAC:EnergyRecoveryVentilator G S1 APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 2.59546E-002
33 ZoneHVAC:EnergyRecoveryVentilator G S1 APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 2.59546E-002
34 Fan:OnOff G S1 APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
35 Fan:OnOff G S1 APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
36 HeatExchanger:AirToAir:SensibleAndLatent G S1 APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 2.59546E-002
37 AirTerminal:SingleDuct:ConstantVolume:NoReheat G S1 APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.27316
38 ZoneHVAC:EnergyRecoveryVentilator G S2 APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 2.59546E-002
39 ZoneHVAC:EnergyRecoveryVentilator G S2 APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 2.59546E-002
40 Fan:OnOff G S2 APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
41 Fan:OnOff G S2 APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
42 HeatExchanger:AirToAir:SensibleAndLatent G S2 APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 2.59546E-002
43 AirTerminal:SingleDuct:ConstantVolume:NoReheat G S2 APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.27895
44 ZoneHVAC:EnergyRecoveryVentilator M SW APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 5.19091E-002
45 ZoneHVAC:EnergyRecoveryVentilator M SW APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 5.19091E-002
46 Fan:OnOff M SW APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 5.19091E-002
47 Fan:OnOff M SW APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 5.19091E-002
48 HeatExchanger:AirToAir:SensibleAndLatent M SW APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 5.19091E-002
49 AirTerminal:SingleDuct:ConstantVolume:NoReheat M SW APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.77850
50 ZoneHVAC:EnergyRecoveryVentilator M NW APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 5.19091E-002
51 ZoneHVAC:EnergyRecoveryVentilator M NW APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 5.19091E-002
52 Fan:OnOff M NW APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 5.19091E-002
53 Fan:OnOff M NW APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 5.19091E-002
54 HeatExchanger:AirToAir:SensibleAndLatent M NW APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 5.19091E-002
55 AirTerminal:SingleDuct:ConstantVolume:NoReheat M NW APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.76775
56 ZoneHVAC:EnergyRecoveryVentilator M SE APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 5.19091E-002
57 ZoneHVAC:EnergyRecoveryVentilator M SE APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 5.19091E-002
58 Fan:OnOff M SE APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 5.19091E-002
59 Fan:OnOff M SE APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 5.19091E-002
60 HeatExchanger:AirToAir:SensibleAndLatent M SE APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 5.19091E-002
61 AirTerminal:SingleDuct:ConstantVolume:NoReheat M SE APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.71492
62 ZoneHVAC:EnergyRecoveryVentilator M NE APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 5.19091E-002
63 ZoneHVAC:EnergyRecoveryVentilator M NE APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 5.19091E-002
64 Fan:OnOff M NE APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 5.19091E-002
65 Fan:OnOff M NE APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 5.19091E-002
66 HeatExchanger:AirToAir:SensibleAndLatent M NE APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 5.19091E-002
67 AirTerminal:SingleDuct:ConstantVolume:NoReheat M NE APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.70431
68 ZoneHVAC:EnergyRecoveryVentilator M N1 APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 5.19091E-002
69 ZoneHVAC:EnergyRecoveryVentilator M N1 APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 5.19091E-002
70 Fan:OnOff M N1 APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 5.19091E-002
71 Fan:OnOff M N1 APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 5.19091E-002
72 HeatExchanger:AirToAir:SensibleAndLatent M N1 APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 5.19091E-002
73 AirTerminal:SingleDuct:ConstantVolume:NoReheat M N1 APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.60388
74 ZoneHVAC:EnergyRecoveryVentilator M N2 APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 5.19091E-002
75 ZoneHVAC:EnergyRecoveryVentilator M N2 APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 5.19091E-002
76 Fan:OnOff M N2 APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 5.19091E-002
77 Fan:OnOff M N2 APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 5.19091E-002
78 HeatExchanger:AirToAir:SensibleAndLatent M N2 APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 5.19091E-002
79 AirTerminal:SingleDuct:ConstantVolume:NoReheat M N2 APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.60281
80 ZoneHVAC:EnergyRecoveryVentilator M S1 APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 5.19091E-002
81 ZoneHVAC:EnergyRecoveryVentilator M S1 APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 5.19091E-002
82 Fan:OnOff M S1 APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 5.19091E-002
83 Fan:OnOff M S1 APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 5.19091E-002
84 HeatExchanger:AirToAir:SensibleAndLatent M S1 APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 5.19091E-002
85 AirTerminal:SingleDuct:ConstantVolume:NoReheat M S1 APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.61417
86 ZoneHVAC:EnergyRecoveryVentilator M S2 APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 5.19091E-002
87 ZoneHVAC:EnergyRecoveryVentilator M S2 APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 5.19091E-002
88 Fan:OnOff M S2 APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 5.19091E-002
89 Fan:OnOff M S2 APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 5.19091E-002
90 HeatExchanger:AirToAir:SensibleAndLatent M S2 APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 5.19091E-002
91 AirTerminal:SingleDuct:ConstantVolume:NoReheat M S2 APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.61321
92 ZoneHVAC:EnergyRecoveryVentilator T SW APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 2.59546E-002
93 ZoneHVAC:EnergyRecoveryVentilator T SW APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 2.59546E-002
94 Fan:OnOff T SW APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
95 Fan:OnOff T SW APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
96 HeatExchanger:AirToAir:SensibleAndLatent T SW APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 2.59546E-002
97 AirTerminal:SingleDuct:ConstantVolume:NoReheat T SW APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.44993
98 ZoneHVAC:EnergyRecoveryVentilator T NW APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 2.59546E-002
99 ZoneHVAC:EnergyRecoveryVentilator T NW APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 2.59546E-002
100 Fan:OnOff T NW APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
101 Fan:OnOff T NW APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
102 HeatExchanger:AirToAir:SensibleAndLatent T NW APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 2.59546E-002
103 AirTerminal:SingleDuct:ConstantVolume:NoReheat T NW APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.44890
104 ZoneHVAC:EnergyRecoveryVentilator T SE APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 2.59546E-002
105 ZoneHVAC:EnergyRecoveryVentilator T SE APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 2.59546E-002
106 Fan:OnOff T SE APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
107 Fan:OnOff T SE APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
108 HeatExchanger:AirToAir:SensibleAndLatent T SE APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 2.59546E-002
109 AirTerminal:SingleDuct:ConstantVolume:NoReheat T SE APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.40313
110 ZoneHVAC:EnergyRecoveryVentilator T NE APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 2.59546E-002
111 ZoneHVAC:EnergyRecoveryVentilator T NE APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 2.59546E-002
112 Fan:OnOff T NE APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
113 Fan:OnOff T NE APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
114 HeatExchanger:AirToAir:SensibleAndLatent T NE APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 2.59546E-002
115 AirTerminal:SingleDuct:ConstantVolume:NoReheat T NE APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.40204
116 ZoneHVAC:EnergyRecoveryVentilator T N1 APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 2.59546E-002
117 ZoneHVAC:EnergyRecoveryVentilator T N1 APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 2.59546E-002
118 Fan:OnOff T N1 APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
119 Fan:OnOff T N1 APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
120 HeatExchanger:AirToAir:SensibleAndLatent T N1 APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 2.59546E-002
121 AirTerminal:SingleDuct:ConstantVolume:NoReheat T N1 APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.36109
122 ZoneHVAC:EnergyRecoveryVentilator T N2 APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 2.59546E-002
123 ZoneHVAC:EnergyRecoveryVentilator T N2 APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 2.59546E-002
124 Fan:OnOff T N2 APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
125 Fan:OnOff T N2 APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
126 HeatExchanger:AirToAir:SensibleAndLatent T N2 APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 2.59546E-002
127 AirTerminal:SingleDuct:ConstantVolume:NoReheat T N2 APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.35964
128 ZoneHVAC:EnergyRecoveryVentilator T S1 APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 2.59546E-002
129 ZoneHVAC:EnergyRecoveryVentilator T S1 APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 2.59546E-002
130 Fan:OnOff T S1 APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
131 Fan:OnOff T S1 APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
132 HeatExchanger:AirToAir:SensibleAndLatent T S1 APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 2.59546E-002
133 AirTerminal:SingleDuct:ConstantVolume:NoReheat T S1 APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.36288
134 ZoneHVAC:EnergyRecoveryVentilator T S2 APARTMENT ERV User-Specified Supply Air Flow Rate [m3/s] 2.59546E-002
135 ZoneHVAC:EnergyRecoveryVentilator T S2 APARTMENT ERV User-Specified Exhaust Air Flow Rate [m3/s] 2.59546E-002
136 Fan:OnOff T S2 APARTMENT ERV SUP FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
137 Fan:OnOff T S2 APARTMENT ERV EXH FAN Design Size Maximum Flow Rate [m3/s] 2.59546E-002
138 HeatExchanger:AirToAir:SensibleAndLatent T S2 APARTMENT OA HEAT EXCHANGER Design Size Nominal Supply Air Flow Rate [m3/s] 2.59546E-002
139 AirTerminal:SingleDuct:ConstantVolume:NoReheat T S2 APARTMENT DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.36143
140 AirLoopHVAC SPLIT GSW Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.34194
141 AirLoopHVAC SPLIT GSW Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.34194
142 AirLoopHVAC SPLIT GSW Sum of Air Terminal Maximum Flow Rates [m3/s] 0.34194
143 AirLoopHVAC SPLIT GSW Adjusted Heating Design Air Flow Rate [m3/s] 0.34194
144 AirLoopHVAC SPLIT GSW Adjusted Cooling Design Air Flow Rate [m3/s] 0.34194
145 AirLoopHVAC SPLIT GSW Adjusted Main Design Air Flow Rate [m3/s] 0.34194
146 AirLoopHVAC SPLIT GSW User Heating Air Flow Ratio [] 1.00000
147 AirLoopHVAC SPLIT GSW Calculated Heating Air Flow Ratio [] 1.00000
148 AirLoopHVAC SPLIT GNW Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.33623
149 AirLoopHVAC SPLIT GNW Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.33623
150 AirLoopHVAC SPLIT GNW Sum of Air Terminal Maximum Flow Rates [m3/s] 0.33623
151 AirLoopHVAC SPLIT GNW Adjusted Heating Design Air Flow Rate [m3/s] 0.33623
152 AirLoopHVAC SPLIT GNW Adjusted Cooling Design Air Flow Rate [m3/s] 0.33623
153 AirLoopHVAC SPLIT GNW Adjusted Main Design Air Flow Rate [m3/s] 0.33623
154 AirLoopHVAC SPLIT GNW User Heating Air Flow Ratio [] 1.00000
155 AirLoopHVAC SPLIT GNW Calculated Heating Air Flow Ratio [] 1.00000
156 AirLoopHVAC SPLIT OFFICE Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.40905
157 AirLoopHVAC SPLIT OFFICE Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.40905
158 AirLoopHVAC SPLIT OFFICE Sum of Air Terminal Maximum Flow Rates [m3/s] 0.40905
159 AirLoopHVAC SPLIT OFFICE Adjusted Heating Design Air Flow Rate [m3/s] 0.40905
160 AirLoopHVAC SPLIT OFFICE Adjusted Cooling Design Air Flow Rate [m3/s] 0.40905
161 AirLoopHVAC SPLIT OFFICE Adjusted Main Design Air Flow Rate [m3/s] 0.40905
162 AirLoopHVAC SPLIT OFFICE User Heating Air Flow Ratio [] 1.00000
163 AirLoopHVAC SPLIT OFFICE Calculated Heating Air Flow Ratio [] 1.00000
164 AirLoopHVAC SPLIT GNE Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.31239
165 AirLoopHVAC SPLIT GNE Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.31239
166 AirLoopHVAC SPLIT GNE Sum of Air Terminal Maximum Flow Rates [m3/s] 0.31239
167 AirLoopHVAC SPLIT GNE Adjusted Heating Design Air Flow Rate [m3/s] 0.31239
168 AirLoopHVAC SPLIT GNE Adjusted Cooling Design Air Flow Rate [m3/s] 0.31239
169 AirLoopHVAC SPLIT GNE Adjusted Main Design Air Flow Rate [m3/s] 0.31239
170 AirLoopHVAC SPLIT GNE User Heating Air Flow Ratio [] 1.00000
171 AirLoopHVAC SPLIT GNE Calculated Heating Air Flow Ratio [] 1.00000
172 AirLoopHVAC SPLIT GN1 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.26786
173 AirLoopHVAC SPLIT GN1 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.26786
174 AirLoopHVAC SPLIT GN1 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.26786
175 AirLoopHVAC SPLIT GN1 Adjusted Heating Design Air Flow Rate [m3/s] 0.26786
176 AirLoopHVAC SPLIT GN1 Adjusted Cooling Design Air Flow Rate [m3/s] 0.26786
177 AirLoopHVAC SPLIT GN1 Adjusted Main Design Air Flow Rate [m3/s] 0.26786
178 AirLoopHVAC SPLIT GN1 User Heating Air Flow Ratio [] 1.00000
179 AirLoopHVAC SPLIT GN1 Calculated Heating Air Flow Ratio [] 1.00000
180 AirLoopHVAC SPLIT GN2 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.26744
181 AirLoopHVAC SPLIT GN2 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.26744
182 AirLoopHVAC SPLIT GN2 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.26744
183 AirLoopHVAC SPLIT GN2 Adjusted Heating Design Air Flow Rate [m3/s] 0.26744
184 AirLoopHVAC SPLIT GN2 Adjusted Cooling Design Air Flow Rate [m3/s] 0.26744
185 AirLoopHVAC SPLIT GN2 Adjusted Main Design Air Flow Rate [m3/s] 0.26744
186 AirLoopHVAC SPLIT GN2 User Heating Air Flow Ratio [] 1.00000
187 AirLoopHVAC SPLIT GN2 Calculated Heating Air Flow Ratio [] 1.00000
188 AirLoopHVAC SPLIT GS1 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.27316
189 AirLoopHVAC SPLIT GS1 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.27316
190 AirLoopHVAC SPLIT GS1 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.27316
191 AirLoopHVAC SPLIT GS1 Adjusted Heating Design Air Flow Rate [m3/s] 0.27316
192 AirLoopHVAC SPLIT GS1 Adjusted Cooling Design Air Flow Rate [m3/s] 0.27316
193 AirLoopHVAC SPLIT GS1 Adjusted Main Design Air Flow Rate [m3/s] 0.27316
194 AirLoopHVAC SPLIT GS1 User Heating Air Flow Ratio [] 1.00000
195 AirLoopHVAC SPLIT GS1 Calculated Heating Air Flow Ratio [] 1.00000
196 AirLoopHVAC SPLIT GS2 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.27895
197 AirLoopHVAC SPLIT GS2 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.27895
198 AirLoopHVAC SPLIT GS2 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.27895
199 AirLoopHVAC SPLIT GS2 Adjusted Heating Design Air Flow Rate [m3/s] 0.27895
200 AirLoopHVAC SPLIT GS2 Adjusted Cooling Design Air Flow Rate [m3/s] 0.27895
201 AirLoopHVAC SPLIT GS2 Adjusted Main Design Air Flow Rate [m3/s] 0.27895
202 AirLoopHVAC SPLIT GS2 User Heating Air Flow Ratio [] 1.00000
203 AirLoopHVAC SPLIT GS2 Calculated Heating Air Flow Ratio [] 1.00000
204 AirLoopHVAC SPLIT MSW Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.77850
205 AirLoopHVAC SPLIT MSW Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.77850
206 AirLoopHVAC SPLIT MSW Sum of Air Terminal Maximum Flow Rates [m3/s] 0.77850
207 AirLoopHVAC SPLIT MSW Adjusted Heating Design Air Flow Rate [m3/s] 0.77850
208 AirLoopHVAC SPLIT MSW Adjusted Cooling Design Air Flow Rate [m3/s] 0.77850
209 AirLoopHVAC SPLIT MSW Adjusted Main Design Air Flow Rate [m3/s] 0.77850
210 AirLoopHVAC SPLIT MSW User Heating Air Flow Ratio [] 1.00000
211 AirLoopHVAC SPLIT MSW Calculated Heating Air Flow Ratio [] 1.00000
212 AirLoopHVAC SPLIT MNW Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.76775
213 AirLoopHVAC SPLIT MNW Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.76775
214 AirLoopHVAC SPLIT MNW Sum of Air Terminal Maximum Flow Rates [m3/s] 0.76775
215 AirLoopHVAC SPLIT MNW Adjusted Heating Design Air Flow Rate [m3/s] 0.76775
216 AirLoopHVAC SPLIT MNW Adjusted Cooling Design Air Flow Rate [m3/s] 0.76775
217 AirLoopHVAC SPLIT MNW Adjusted Main Design Air Flow Rate [m3/s] 0.76775
218 AirLoopHVAC SPLIT MNW User Heating Air Flow Ratio [] 1.00000
219 AirLoopHVAC SPLIT MNW Calculated Heating Air Flow Ratio [] 1.00000
220 AirLoopHVAC SPLIT MSE Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.71492
221 AirLoopHVAC SPLIT MSE Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.71492
222 AirLoopHVAC SPLIT MSE Sum of Air Terminal Maximum Flow Rates [m3/s] 0.71492
223 AirLoopHVAC SPLIT MSE Adjusted Heating Design Air Flow Rate [m3/s] 0.71492
224 AirLoopHVAC SPLIT MSE Adjusted Cooling Design Air Flow Rate [m3/s] 0.71492
225 AirLoopHVAC SPLIT MSE Adjusted Main Design Air Flow Rate [m3/s] 0.71492
226 AirLoopHVAC SPLIT MSE User Heating Air Flow Ratio [] 1.00000
227 AirLoopHVAC SPLIT MSE Calculated Heating Air Flow Ratio [] 1.00000
228 AirLoopHVAC SPLIT MNE Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.70431
229 AirLoopHVAC SPLIT MNE Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.70431
230 AirLoopHVAC SPLIT MNE Sum of Air Terminal Maximum Flow Rates [m3/s] 0.70431
231 AirLoopHVAC SPLIT MNE Adjusted Heating Design Air Flow Rate [m3/s] 0.70431
232 AirLoopHVAC SPLIT MNE Adjusted Cooling Design Air Flow Rate [m3/s] 0.70431
233 AirLoopHVAC SPLIT MNE Adjusted Main Design Air Flow Rate [m3/s] 0.70431
234 AirLoopHVAC SPLIT MNE User Heating Air Flow Ratio [] 1.00000
235 AirLoopHVAC SPLIT MNE Calculated Heating Air Flow Ratio [] 1.00000
236 AirLoopHVAC SPLIT MN1 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.60388
237 AirLoopHVAC SPLIT MN1 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.60388
238 AirLoopHVAC SPLIT MN1 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.60388
239 AirLoopHVAC SPLIT MN1 Adjusted Heating Design Air Flow Rate [m3/s] 0.60388
240 AirLoopHVAC SPLIT MN1 Adjusted Cooling Design Air Flow Rate [m3/s] 0.60388
241 AirLoopHVAC SPLIT MN1 Adjusted Main Design Air Flow Rate [m3/s] 0.60388
242 AirLoopHVAC SPLIT MN1 User Heating Air Flow Ratio [] 1.00000
243 AirLoopHVAC SPLIT MN1 Calculated Heating Air Flow Ratio [] 1.00000
244 AirLoopHVAC SPLIT MN2 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.60281
245 AirLoopHVAC SPLIT MN2 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.60281
246 AirLoopHVAC SPLIT MN2 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.60281
247 AirLoopHVAC SPLIT MN2 Adjusted Heating Design Air Flow Rate [m3/s] 0.60281
248 AirLoopHVAC SPLIT MN2 Adjusted Cooling Design Air Flow Rate [m3/s] 0.60281
249 AirLoopHVAC SPLIT MN2 Adjusted Main Design Air Flow Rate [m3/s] 0.60281
250 AirLoopHVAC SPLIT MN2 User Heating Air Flow Ratio [] 1.00000
251 AirLoopHVAC SPLIT MN2 Calculated Heating Air Flow Ratio [] 1.00000
252 AirLoopHVAC SPLIT MS1 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.61417
253 AirLoopHVAC SPLIT MS1 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.61417
254 AirLoopHVAC SPLIT MS1 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.61417
255 AirLoopHVAC SPLIT MS1 Adjusted Heating Design Air Flow Rate [m3/s] 0.61417
256 AirLoopHVAC SPLIT MS1 Adjusted Cooling Design Air Flow Rate [m3/s] 0.61417
257 AirLoopHVAC SPLIT MS1 Adjusted Main Design Air Flow Rate [m3/s] 0.61417
258 AirLoopHVAC SPLIT MS1 User Heating Air Flow Ratio [] 1.00000
259 AirLoopHVAC SPLIT MS1 Calculated Heating Air Flow Ratio [] 1.00000
260 AirLoopHVAC SPLIT MS2 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.61321
261 AirLoopHVAC SPLIT MS2 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.61321
262 AirLoopHVAC SPLIT MS2 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.61321
263 AirLoopHVAC SPLIT MS2 Adjusted Heating Design Air Flow Rate [m3/s] 0.61321
264 AirLoopHVAC SPLIT MS2 Adjusted Cooling Design Air Flow Rate [m3/s] 0.61321
265 AirLoopHVAC SPLIT MS2 Adjusted Main Design Air Flow Rate [m3/s] 0.61321
266 AirLoopHVAC SPLIT MS2 User Heating Air Flow Ratio [] 1.00000
267 AirLoopHVAC SPLIT MS2 Calculated Heating Air Flow Ratio [] 1.00000
268 AirLoopHVAC SPLIT TSW Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.44993
269 AirLoopHVAC SPLIT TSW Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.44993
270 AirLoopHVAC SPLIT TSW Sum of Air Terminal Maximum Flow Rates [m3/s] 0.44993
271 AirLoopHVAC SPLIT TSW Adjusted Heating Design Air Flow Rate [m3/s] 0.44993
272 AirLoopHVAC SPLIT TSW Adjusted Cooling Design Air Flow Rate [m3/s] 0.44993
273 AirLoopHVAC SPLIT TSW Adjusted Main Design Air Flow Rate [m3/s] 0.44993
274 AirLoopHVAC SPLIT TSW User Heating Air Flow Ratio [] 1.00000
275 AirLoopHVAC SPLIT TSW Calculated Heating Air Flow Ratio [] 1.00000
276 AirLoopHVAC SPLIT TNW Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.44890
277 AirLoopHVAC SPLIT TNW Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.44890
278 AirLoopHVAC SPLIT TNW Sum of Air Terminal Maximum Flow Rates [m3/s] 0.44890
279 AirLoopHVAC SPLIT TNW Adjusted Heating Design Air Flow Rate [m3/s] 0.44890
280 AirLoopHVAC SPLIT TNW Adjusted Cooling Design Air Flow Rate [m3/s] 0.44890
281 AirLoopHVAC SPLIT TNW Adjusted Main Design Air Flow Rate [m3/s] 0.44890
282 AirLoopHVAC SPLIT TNW User Heating Air Flow Ratio [] 1.00000
283 AirLoopHVAC SPLIT TNW Calculated Heating Air Flow Ratio [] 1.00000
284 AirLoopHVAC SPLIT TSE Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.40313
285 AirLoopHVAC SPLIT TSE Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.40313
286 AirLoopHVAC SPLIT TSE Sum of Air Terminal Maximum Flow Rates [m3/s] 0.40313
287 AirLoopHVAC SPLIT TSE Adjusted Heating Design Air Flow Rate [m3/s] 0.40313
288 AirLoopHVAC SPLIT TSE Adjusted Cooling Design Air Flow Rate [m3/s] 0.40313
289 AirLoopHVAC SPLIT TSE Adjusted Main Design Air Flow Rate [m3/s] 0.40313
290 AirLoopHVAC SPLIT TSE User Heating Air Flow Ratio [] 1.00000
291 AirLoopHVAC SPLIT TSE Calculated Heating Air Flow Ratio [] 1.00000
292 AirLoopHVAC SPLIT TNE Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.40204
293 AirLoopHVAC SPLIT TNE Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.40204
294 AirLoopHVAC SPLIT TNE Sum of Air Terminal Maximum Flow Rates [m3/s] 0.40204
295 AirLoopHVAC SPLIT TNE Adjusted Heating Design Air Flow Rate [m3/s] 0.40204
296 AirLoopHVAC SPLIT TNE Adjusted Cooling Design Air Flow Rate [m3/s] 0.40204
297 AirLoopHVAC SPLIT TNE Adjusted Main Design Air Flow Rate [m3/s] 0.40204
298 AirLoopHVAC SPLIT TNE User Heating Air Flow Ratio [] 1.00000
299 AirLoopHVAC SPLIT TNE Calculated Heating Air Flow Ratio [] 1.00000
300 AirLoopHVAC SPLIT TN1 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.36109
301 AirLoopHVAC SPLIT TN1 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.36109
302 AirLoopHVAC SPLIT TN1 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.36109
303 AirLoopHVAC SPLIT TN1 Adjusted Heating Design Air Flow Rate [m3/s] 0.36109
304 AirLoopHVAC SPLIT TN1 Adjusted Cooling Design Air Flow Rate [m3/s] 0.36109
305 AirLoopHVAC SPLIT TN1 Adjusted Main Design Air Flow Rate [m3/s] 0.36109
306 AirLoopHVAC SPLIT TN1 User Heating Air Flow Ratio [] 1.00000
307 AirLoopHVAC SPLIT TN1 Calculated Heating Air Flow Ratio [] 1.00000
308 AirLoopHVAC SPLIT TN2 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.35964
309 AirLoopHVAC SPLIT TN2 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.35964
310 AirLoopHVAC SPLIT TN2 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.35964
311 AirLoopHVAC SPLIT TN2 Adjusted Heating Design Air Flow Rate [m3/s] 0.35964
312 AirLoopHVAC SPLIT TN2 Adjusted Cooling Design Air Flow Rate [m3/s] 0.35964
313 AirLoopHVAC SPLIT TN2 Adjusted Main Design Air Flow Rate [m3/s] 0.35964
314 AirLoopHVAC SPLIT TN2 User Heating Air Flow Ratio [] 1.00000
315 AirLoopHVAC SPLIT TN2 Calculated Heating Air Flow Ratio [] 1.00000
316 AirLoopHVAC SPLIT TS1 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.36288
317 AirLoopHVAC SPLIT TS1 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.36288
318 AirLoopHVAC SPLIT TS1 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.36288
319 AirLoopHVAC SPLIT TS1 Adjusted Heating Design Air Flow Rate [m3/s] 0.36288
320 AirLoopHVAC SPLIT TS1 Adjusted Cooling Design Air Flow Rate [m3/s] 0.36288
321 AirLoopHVAC SPLIT TS1 Adjusted Main Design Air Flow Rate [m3/s] 0.36288
322 AirLoopHVAC SPLIT TS1 User Heating Air Flow Ratio [] 1.00000
323 AirLoopHVAC SPLIT TS1 Calculated Heating Air Flow Ratio [] 1.00000
324 AirLoopHVAC SPLIT TS2 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.36143
325 AirLoopHVAC SPLIT TS2 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.36143
326 AirLoopHVAC SPLIT TS2 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.36143
327 AirLoopHVAC SPLIT TS2 Adjusted Heating Design Air Flow Rate [m3/s] 0.36143
328 AirLoopHVAC SPLIT TS2 Adjusted Cooling Design Air Flow Rate [m3/s] 0.36143
329 AirLoopHVAC SPLIT TS2 Adjusted Main Design Air Flow Rate [m3/s] 0.36143
330 AirLoopHVAC SPLIT TS2 User Heating Air Flow Ratio [] 1.00000
331 AirLoopHVAC SPLIT TS2 Calculated Heating Air Flow Ratio [] 1.00000
332 AirLoopHVAC SPLIT GSW Design Supply Air Flow Rate [m3/s] 0.34194
333 AirLoopHVAC SPLIT GNW Design Supply Air Flow Rate [m3/s] 0.33623
334 AirLoopHVAC SPLIT OFFICE Design Supply Air Flow Rate [m3/s] 0.40905
335 AirLoopHVAC SPLIT GNE Design Supply Air Flow Rate [m3/s] 0.31239
336 AirLoopHVAC SPLIT GN1 Design Supply Air Flow Rate [m3/s] 0.26786
337 AirLoopHVAC SPLIT GN2 Design Supply Air Flow Rate [m3/s] 0.26744
338 AirLoopHVAC SPLIT GS1 Design Supply Air Flow Rate [m3/s] 0.27316
339 AirLoopHVAC SPLIT GS2 Design Supply Air Flow Rate [m3/s] 0.27895
340 AirLoopHVAC SPLIT MSW Design Supply Air Flow Rate [m3/s] 0.77850
341 AirLoopHVAC SPLIT MNW Design Supply Air Flow Rate [m3/s] 0.76775
342 AirLoopHVAC SPLIT MSE Design Supply Air Flow Rate [m3/s] 0.71492
343 AirLoopHVAC SPLIT MNE Design Supply Air Flow Rate [m3/s] 0.70431
344 AirLoopHVAC SPLIT MN1 Design Supply Air Flow Rate [m3/s] 0.60388
345 AirLoopHVAC SPLIT MN2 Design Supply Air Flow Rate [m3/s] 0.60281
346 AirLoopHVAC SPLIT MS1 Design Supply Air Flow Rate [m3/s] 0.61417
347 AirLoopHVAC SPLIT MS2 Design Supply Air Flow Rate [m3/s] 0.61321
348 AirLoopHVAC SPLIT TSW Design Supply Air Flow Rate [m3/s] 0.44993
349 AirLoopHVAC SPLIT TNW Design Supply Air Flow Rate [m3/s] 0.44890
350 AirLoopHVAC SPLIT TSE Design Supply Air Flow Rate [m3/s] 0.40313
351 AirLoopHVAC SPLIT TNE Design Supply Air Flow Rate [m3/s] 0.40204
352 AirLoopHVAC SPLIT TN1 Design Supply Air Flow Rate [m3/s] 0.36109
353 AirLoopHVAC SPLIT TN2 Design Supply Air Flow Rate [m3/s] 0.35964
354 AirLoopHVAC SPLIT TS1 Design Supply Air Flow Rate [m3/s] 0.36288
355 AirLoopHVAC SPLIT TS2 Design Supply Air Flow Rate [m3/s] 0.36143
356 Controller:OutdoorAir SPLIT GSW_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.34194
357 Controller:OutdoorAir SPLIT GSW_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.59546E-002
358 AirLoopHVAC:UnitarySystem SPLIT GSW_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.34194
359 AirLoopHVAC:UnitarySystem SPLIT GSW_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.34194
360 AirLoopHVAC:UnitarySystem SPLIT GSW_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.34194
361 AirLoopHVAC:UnitarySystem SPLIT GSW_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.34194
362 AirLoopHVAC:UnitarySystem SPLIT GSW_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 5660.35487
363 AirLoopHVAC:UnitarySystem SPLIT GSW_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 3792.43776
364 AirLoopHVAC:UnitarySystem SPLIT GSW_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
365 AirLoopHVAC:UnitarySystem SPLIT GSW_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 5660.35487
366 AirLoopHVAC:UnitarySystem SPLIT GSW_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
367 Fan:OnOff SPLIT GSW SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.34194
368 Coil:Cooling:DX:SingleSpeed SPLIT GSW HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.34194
369 Coil:Cooling:DX:SingleSpeed SPLIT GSW HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 5660.35487
370 Coil:Cooling:DX:SingleSpeed SPLIT GSW HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
371 Coil:Heating:DX:SingleSpeed SPLIT GSW HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.34194
372 Coil:Heating:DX:SingleSpeed SPLIT GSW HEATING COIL Design Size Gross Rated Heating Capacity [W] 5660.35487
373 Coil:Heating:Electric SPLIT GSW_SUPPHEATCOIL Design Size Nominal Capacity [W] 5660.35487
374 Controller:OutdoorAir SPLIT GNW_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.33623
375 Controller:OutdoorAir SPLIT GNW_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.59546E-002
376 AirLoopHVAC:UnitarySystem SPLIT GNW_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.33623
377 AirLoopHVAC:UnitarySystem SPLIT GNW_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.33623
378 AirLoopHVAC:UnitarySystem SPLIT GNW_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.33623
379 AirLoopHVAC:UnitarySystem SPLIT GNW_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.33623
380 AirLoopHVAC:UnitarySystem SPLIT GNW_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 5565.76915
381 AirLoopHVAC:UnitarySystem SPLIT GNW_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 3729.06533
382 AirLoopHVAC:UnitarySystem SPLIT GNW_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
383 AirLoopHVAC:UnitarySystem SPLIT GNW_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 5565.76915
384 AirLoopHVAC:UnitarySystem SPLIT GNW_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
385 Fan:OnOff SPLIT GNW SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.33623
386 Coil:Cooling:DX:SingleSpeed SPLIT GNW HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.33623
387 Coil:Cooling:DX:SingleSpeed SPLIT GNW HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 5565.76915
388 Coil:Cooling:DX:SingleSpeed SPLIT GNW HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
389 Coil:Heating:DX:SingleSpeed SPLIT GNW HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.33623
390 Coil:Heating:DX:SingleSpeed SPLIT GNW HEATING COIL Design Size Gross Rated Heating Capacity [W] 5565.76915
391 Coil:Heating:Electric SPLIT GNW_SUPPHEATCOIL Design Size Nominal Capacity [W] 5565.76915
392 Controller:OutdoorAir SPLIT OFFICE_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.40905
393 Controller:OutdoorAir SPLIT OFFICE_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 3.81060E-002
394 AirLoopHVAC:UnitarySystem SPLIT OFFICE_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.40905
395 AirLoopHVAC:UnitarySystem SPLIT OFFICE_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.40905
396 AirLoopHVAC:UnitarySystem SPLIT OFFICE_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.40905
397 AirLoopHVAC:UnitarySystem SPLIT OFFICE_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.40905
398 AirLoopHVAC:UnitarySystem SPLIT OFFICE_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 6771.15825
399 AirLoopHVAC:UnitarySystem SPLIT OFFICE_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 4536.67603
400 AirLoopHVAC:UnitarySystem SPLIT OFFICE_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
401 AirLoopHVAC:UnitarySystem SPLIT OFFICE_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 6771.15825
402 AirLoopHVAC:UnitarySystem SPLIT OFFICE_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
403 Fan:OnOff SPLIT OFFICE SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.40905
404 Coil:Cooling:DX:SingleSpeed SPLIT OFFICE HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.40905
405 Coil:Cooling:DX:SingleSpeed SPLIT OFFICE HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 6771.15825
406 Coil:Cooling:DX:SingleSpeed SPLIT OFFICE HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
407 Coil:Heating:DX:SingleSpeed SPLIT OFFICE HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.40905
408 Coil:Heating:DX:SingleSpeed SPLIT OFFICE HEATING COIL Design Size Gross Rated Heating Capacity [W] 6771.15825
409 Coil:Heating:Electric SPLIT OFFICE_SUPPHEATCOIL Design Size Nominal Capacity [W] 6771.15825
410 Controller:OutdoorAir SPLIT GNE_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.31239
411 Controller:OutdoorAir SPLIT GNE_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.59546E-002
412 AirLoopHVAC:UnitarySystem SPLIT GNE_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.31239
413 AirLoopHVAC:UnitarySystem SPLIT GNE_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.31239
414 AirLoopHVAC:UnitarySystem SPLIT GNE_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.31239
415 AirLoopHVAC:UnitarySystem SPLIT GNE_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.31239
416 AirLoopHVAC:UnitarySystem SPLIT GNE_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 5171.09517
417 AirLoopHVAC:UnitarySystem SPLIT GNE_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 3464.63377
418 AirLoopHVAC:UnitarySystem SPLIT GNE_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
419 AirLoopHVAC:UnitarySystem SPLIT GNE_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 5171.09517
420 AirLoopHVAC:UnitarySystem SPLIT GNE_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
421 Fan:OnOff SPLIT GNE SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.31239
422 Coil:Cooling:DX:SingleSpeed SPLIT GNE HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.31239
423 Coil:Cooling:DX:SingleSpeed SPLIT GNE HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 5171.09517
424 Coil:Cooling:DX:SingleSpeed SPLIT GNE HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
425 Coil:Heating:DX:SingleSpeed SPLIT GNE HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.31239
426 Coil:Heating:DX:SingleSpeed SPLIT GNE HEATING COIL Design Size Gross Rated Heating Capacity [W] 5171.09517
427 Coil:Heating:Electric SPLIT GNE_SUPPHEATCOIL Design Size Nominal Capacity [W] 5171.09517
428 Controller:OutdoorAir SPLIT GN1_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.26786
429 Controller:OutdoorAir SPLIT GN1_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.59546E-002
430 AirLoopHVAC:UnitarySystem SPLIT GN1_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.26786
431 AirLoopHVAC:UnitarySystem SPLIT GN1_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.26786
432 AirLoopHVAC:UnitarySystem SPLIT GN1_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.26786
433 AirLoopHVAC:UnitarySystem SPLIT GN1_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.26786
434 AirLoopHVAC:UnitarySystem SPLIT GN1_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 4434.00226
435 AirLoopHVAC:UnitarySystem SPLIT GN1_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 2970.78152
436 AirLoopHVAC:UnitarySystem SPLIT GN1_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
437 AirLoopHVAC:UnitarySystem SPLIT GN1_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 4434.00226
438 AirLoopHVAC:UnitarySystem SPLIT GN1_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
439 Fan:OnOff SPLIT GN1 SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.26786
440 Coil:Cooling:DX:SingleSpeed SPLIT GN1 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.26786
441 Coil:Cooling:DX:SingleSpeed SPLIT GN1 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 4434.00226
442 Coil:Cooling:DX:SingleSpeed SPLIT GN1 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
443 Coil:Heating:DX:SingleSpeed SPLIT GN1 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.26786
444 Coil:Heating:DX:SingleSpeed SPLIT GN1 HEATING COIL Design Size Gross Rated Heating Capacity [W] 4434.00226
445 Coil:Heating:Electric SPLIT GN1_SUPPHEATCOIL Design Size Nominal Capacity [W] 4434.00226
446 Controller:OutdoorAir SPLIT GN2_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.26744
447 Controller:OutdoorAir SPLIT GN2_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.59546E-002
448 AirLoopHVAC:UnitarySystem SPLIT GN2_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.26744
449 AirLoopHVAC:UnitarySystem SPLIT GN2_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.26744
450 AirLoopHVAC:UnitarySystem SPLIT GN2_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.26744
451 AirLoopHVAC:UnitarySystem SPLIT GN2_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.26744
452 AirLoopHVAC:UnitarySystem SPLIT GN2_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 4427.01017
453 AirLoopHVAC:UnitarySystem SPLIT GN2_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 2966.09681
454 AirLoopHVAC:UnitarySystem SPLIT GN2_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
455 AirLoopHVAC:UnitarySystem SPLIT GN2_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 4427.01017
456 AirLoopHVAC:UnitarySystem SPLIT GN2_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
457 Fan:OnOff SPLIT GN2 SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.26744
458 Coil:Cooling:DX:SingleSpeed SPLIT GN2 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.26744
459 Coil:Cooling:DX:SingleSpeed SPLIT GN2 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 4427.01017
460 Coil:Cooling:DX:SingleSpeed SPLIT GN2 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
461 Coil:Heating:DX:SingleSpeed SPLIT GN2 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.26744
462 Coil:Heating:DX:SingleSpeed SPLIT GN2 HEATING COIL Design Size Gross Rated Heating Capacity [W] 4427.01017
463 Coil:Heating:Electric SPLIT GN2_SUPPHEATCOIL Design Size Nominal Capacity [W] 4427.01017
464 Controller:OutdoorAir SPLIT GS1_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.27316
465 Controller:OutdoorAir SPLIT GS1_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.59546E-002
466 AirLoopHVAC:UnitarySystem SPLIT GS1_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.27316
467 AirLoopHVAC:UnitarySystem SPLIT GS1_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.27316
468 AirLoopHVAC:UnitarySystem SPLIT GS1_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.27316
469 AirLoopHVAC:UnitarySystem SPLIT GS1_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.27316
470 AirLoopHVAC:UnitarySystem SPLIT GS1_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 4521.76190
471 AirLoopHVAC:UnitarySystem SPLIT GS1_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 3029.58047
472 AirLoopHVAC:UnitarySystem SPLIT GS1_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
473 AirLoopHVAC:UnitarySystem SPLIT GS1_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 4521.76190
474 AirLoopHVAC:UnitarySystem SPLIT GS1_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
475 Fan:OnOff SPLIT GS1 SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.27316
476 Coil:Cooling:DX:SingleSpeed SPLIT GS1 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.27316
477 Coil:Cooling:DX:SingleSpeed SPLIT GS1 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 4521.76190
478 Coil:Cooling:DX:SingleSpeed SPLIT GS1 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
479 Coil:Heating:DX:SingleSpeed SPLIT GS1 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.27316
480 Coil:Heating:DX:SingleSpeed SPLIT GS1 HEATING COIL Design Size Gross Rated Heating Capacity [W] 4521.76190
481 Coil:Heating:Electric SPLIT GS1_SUPPHEATCOIL Design Size Nominal Capacity [W] 4521.76190
482 Controller:OutdoorAir SPLIT GS2_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.27895
483 Controller:OutdoorAir SPLIT GS2_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.59546E-002
484 AirLoopHVAC:UnitarySystem SPLIT GS2_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.27895
485 AirLoopHVAC:UnitarySystem SPLIT GS2_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.27895
486 AirLoopHVAC:UnitarySystem SPLIT GS2_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.27895
487 AirLoopHVAC:UnitarySystem SPLIT GS2_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.27895
488 AirLoopHVAC:UnitarySystem SPLIT GS2_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 4617.61032
489 AirLoopHVAC:UnitarySystem SPLIT GS2_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 3093.79891
490 AirLoopHVAC:UnitarySystem SPLIT GS2_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
491 AirLoopHVAC:UnitarySystem SPLIT GS2_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 4617.61032
492 AirLoopHVAC:UnitarySystem SPLIT GS2_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
493 Fan:OnOff SPLIT GS2 SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.27895
494 Coil:Cooling:DX:SingleSpeed SPLIT GS2 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.27895
495 Coil:Cooling:DX:SingleSpeed SPLIT GS2 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 4617.61032
496 Coil:Cooling:DX:SingleSpeed SPLIT GS2 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
497 Coil:Heating:DX:SingleSpeed SPLIT GS2 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.27895
498 Coil:Heating:DX:SingleSpeed SPLIT GS2 HEATING COIL Design Size Gross Rated Heating Capacity [W] 4617.61032
499 Coil:Heating:Electric SPLIT GS2_SUPPHEATCOIL Design Size Nominal Capacity [W] 4617.61032
500 Controller:OutdoorAir SPLIT MSW_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.77850
501 Controller:OutdoorAir SPLIT MSW_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 5.19091E-002
502 AirLoopHVAC:UnitarySystem SPLIT MSW_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.77850
503 AirLoopHVAC:UnitarySystem SPLIT MSW_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.77850
504 AirLoopHVAC:UnitarySystem SPLIT MSW_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.77850
505 AirLoopHVAC:UnitarySystem SPLIT MSW_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.77850
506 AirLoopHVAC:UnitarySystem SPLIT MSW_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 12886.89837
507 AirLoopHVAC:UnitarySystem SPLIT MSW_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 8634.22191
508 AirLoopHVAC:UnitarySystem SPLIT MSW_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
509 AirLoopHVAC:UnitarySystem SPLIT MSW_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 12886.89837
510 AirLoopHVAC:UnitarySystem SPLIT MSW_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
511 Fan:OnOff SPLIT MSW SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.77850
512 Coil:Cooling:DX:SingleSpeed SPLIT MSW HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.77850
513 Coil:Cooling:DX:SingleSpeed SPLIT MSW HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 12886.89837
514 Coil:Cooling:DX:SingleSpeed SPLIT MSW HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
515 Coil:Heating:DX:SingleSpeed SPLIT MSW HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.77850
516 Coil:Heating:DX:SingleSpeed SPLIT MSW HEATING COIL Design Size Gross Rated Heating Capacity [W] 12886.89837
517 Coil:Heating:Electric SPLIT MSW_SUPPHEATCOIL Design Size Nominal Capacity [W] 12886.89837
518 Controller:OutdoorAir SPLIT MNW_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.76775
519 Controller:OutdoorAir SPLIT MNW_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 5.19091E-002
520 AirLoopHVAC:UnitarySystem SPLIT MNW_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.76775
521 AirLoopHVAC:UnitarySystem SPLIT MNW_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.76775
522 AirLoopHVAC:UnitarySystem SPLIT MNW_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.76775
523 AirLoopHVAC:UnitarySystem SPLIT MNW_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.76775
524 AirLoopHVAC:UnitarySystem SPLIT MNW_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 12709.01033
525 AirLoopHVAC:UnitarySystem SPLIT MNW_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 8515.03692
526 AirLoopHVAC:UnitarySystem SPLIT MNW_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
527 AirLoopHVAC:UnitarySystem SPLIT MNW_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 12709.01033
528 AirLoopHVAC:UnitarySystem SPLIT MNW_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
529 Fan:OnOff SPLIT MNW SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.76775
530 Coil:Cooling:DX:SingleSpeed SPLIT MNW HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.76775
531 Coil:Cooling:DX:SingleSpeed SPLIT MNW HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 12709.01033
532 Coil:Cooling:DX:SingleSpeed SPLIT MNW HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
533 Coil:Heating:DX:SingleSpeed SPLIT MNW HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.76775
534 Coil:Heating:DX:SingleSpeed SPLIT MNW HEATING COIL Design Size Gross Rated Heating Capacity [W] 12709.01033
535 Coil:Heating:Electric SPLIT MNW_SUPPHEATCOIL Design Size Nominal Capacity [W] 12709.01033
536 Controller:OutdoorAir SPLIT MSE_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.71492
537 Controller:OutdoorAir SPLIT MSE_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 5.19091E-002
538 AirLoopHVAC:UnitarySystem SPLIT MSE_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.71492
539 AirLoopHVAC:UnitarySystem SPLIT MSE_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.71492
540 AirLoopHVAC:UnitarySystem SPLIT MSE_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.71492
541 AirLoopHVAC:UnitarySystem SPLIT MSE_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.71492
542 AirLoopHVAC:UnitarySystem SPLIT MSE_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 11834.39395
543 AirLoopHVAC:UnitarySystem SPLIT MSE_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 7929.04395
544 AirLoopHVAC:UnitarySystem SPLIT MSE_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
545 AirLoopHVAC:UnitarySystem SPLIT MSE_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 11834.39395
546 AirLoopHVAC:UnitarySystem SPLIT MSE_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
547 Fan:OnOff SPLIT MSE SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.71492
548 Coil:Cooling:DX:SingleSpeed SPLIT MSE HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.71492
549 Coil:Cooling:DX:SingleSpeed SPLIT MSE HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 11834.39395
550 Coil:Cooling:DX:SingleSpeed SPLIT MSE HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
551 Coil:Heating:DX:SingleSpeed SPLIT MSE HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.71492
552 Coil:Heating:DX:SingleSpeed SPLIT MSE HEATING COIL Design Size Gross Rated Heating Capacity [W] 11834.39395
553 Coil:Heating:Electric SPLIT MSE_SUPPHEATCOIL Design Size Nominal Capacity [W] 11834.39395
554 Controller:OutdoorAir SPLIT MNE_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.70431
555 Controller:OutdoorAir SPLIT MNE_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 5.19091E-002
556 AirLoopHVAC:UnitarySystem SPLIT MNE_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.70431
557 AirLoopHVAC:UnitarySystem SPLIT MNE_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.70431
558 AirLoopHVAC:UnitarySystem SPLIT MNE_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.70431
559 AirLoopHVAC:UnitarySystem SPLIT MNE_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.70431
560 AirLoopHVAC:UnitarySystem SPLIT MNE_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 11658.89659
561 AirLoopHVAC:UnitarySystem SPLIT MNE_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 7811.46072
562 AirLoopHVAC:UnitarySystem SPLIT MNE_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
563 AirLoopHVAC:UnitarySystem SPLIT MNE_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 11658.89659
564 AirLoopHVAC:UnitarySystem SPLIT MNE_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
565 Fan:OnOff SPLIT MNE SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.70431
566 Coil:Cooling:DX:SingleSpeed SPLIT MNE HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.70431
567 Coil:Cooling:DX:SingleSpeed SPLIT MNE HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 11658.89659
568 Coil:Cooling:DX:SingleSpeed SPLIT MNE HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
569 Coil:Heating:DX:SingleSpeed SPLIT MNE HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.70431
570 Coil:Heating:DX:SingleSpeed SPLIT MNE HEATING COIL Design Size Gross Rated Heating Capacity [W] 11658.89659
571 Coil:Heating:Electric SPLIT MNE_SUPPHEATCOIL Design Size Nominal Capacity [W] 11658.89659
572 Controller:OutdoorAir SPLIT MN1_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.60388
573 Controller:OutdoorAir SPLIT MN1_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 5.19091E-002
574 AirLoopHVAC:UnitarySystem SPLIT MN1_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.60388
575 AirLoopHVAC:UnitarySystem SPLIT MN1_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.60388
576 AirLoopHVAC:UnitarySystem SPLIT MN1_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.60388
577 AirLoopHVAC:UnitarySystem SPLIT MN1_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.60388
578 AirLoopHVAC:UnitarySystem SPLIT MN1_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 9996.40209
579 AirLoopHVAC:UnitarySystem SPLIT MN1_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 6697.58940
580 AirLoopHVAC:UnitarySystem SPLIT MN1_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
581 AirLoopHVAC:UnitarySystem SPLIT MN1_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 9996.40209
582 AirLoopHVAC:UnitarySystem SPLIT MN1_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
583 Fan:OnOff SPLIT MN1 SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.60388
584 Coil:Cooling:DX:SingleSpeed SPLIT MN1 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.60388
585 Coil:Cooling:DX:SingleSpeed SPLIT MN1 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 9996.40209
586 Coil:Cooling:DX:SingleSpeed SPLIT MN1 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
587 Coil:Heating:DX:SingleSpeed SPLIT MN1 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.60388
588 Coil:Heating:DX:SingleSpeed SPLIT MN1 HEATING COIL Design Size Gross Rated Heating Capacity [W] 9996.40209
589 Coil:Heating:Electric SPLIT MN1_SUPPHEATCOIL Design Size Nominal Capacity [W] 9996.40209
590 Controller:OutdoorAir SPLIT MN2_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.60281
591 Controller:OutdoorAir SPLIT MN2_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 5.19091E-002
592 AirLoopHVAC:UnitarySystem SPLIT MN2_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.60281
593 AirLoopHVAC:UnitarySystem SPLIT MN2_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.60281
594 AirLoopHVAC:UnitarySystem SPLIT MN2_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.60281
595 AirLoopHVAC:UnitarySystem SPLIT MN2_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.60281
596 AirLoopHVAC:UnitarySystem SPLIT MN2_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 9978.72814
597 AirLoopHVAC:UnitarySystem SPLIT MN2_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 6685.74786
598 AirLoopHVAC:UnitarySystem SPLIT MN2_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
599 AirLoopHVAC:UnitarySystem SPLIT MN2_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 9978.72814
600 AirLoopHVAC:UnitarySystem SPLIT MN2_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
601 Fan:OnOff SPLIT MN2 SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.60281
602 Coil:Cooling:DX:SingleSpeed SPLIT MN2 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.60281
603 Coil:Cooling:DX:SingleSpeed SPLIT MN2 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 9978.72814
604 Coil:Cooling:DX:SingleSpeed SPLIT MN2 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
605 Coil:Heating:DX:SingleSpeed SPLIT MN2 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.60281
606 Coil:Heating:DX:SingleSpeed SPLIT MN2 HEATING COIL Design Size Gross Rated Heating Capacity [W] 9978.72814
607 Coil:Heating:Electric SPLIT MN2_SUPPHEATCOIL Design Size Nominal Capacity [W] 9978.72814
608 Controller:OutdoorAir SPLIT MS1_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.61417
609 Controller:OutdoorAir SPLIT MS1_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 5.19091E-002
610 AirLoopHVAC:UnitarySystem SPLIT MS1_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.61417
611 AirLoopHVAC:UnitarySystem SPLIT MS1_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.61417
612 AirLoopHVAC:UnitarySystem SPLIT MS1_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.61417
613 AirLoopHVAC:UnitarySystem SPLIT MS1_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.61417
614 AirLoopHVAC:UnitarySystem SPLIT MS1_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 10166.68304
615 AirLoopHVAC:UnitarySystem SPLIT MS1_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 6811.67764
616 AirLoopHVAC:UnitarySystem SPLIT MS1_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
617 AirLoopHVAC:UnitarySystem SPLIT MS1_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 10166.68304
618 AirLoopHVAC:UnitarySystem SPLIT MS1_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
619 Fan:OnOff SPLIT MS1 SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.61417
620 Coil:Cooling:DX:SingleSpeed SPLIT MS1 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.61417
621 Coil:Cooling:DX:SingleSpeed SPLIT MS1 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 10166.68304
622 Coil:Cooling:DX:SingleSpeed SPLIT MS1 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
623 Coil:Heating:DX:SingleSpeed SPLIT MS1 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.61417
624 Coil:Heating:DX:SingleSpeed SPLIT MS1 HEATING COIL Design Size Gross Rated Heating Capacity [W] 10166.68304
625 Coil:Heating:Electric SPLIT MS1_SUPPHEATCOIL Design Size Nominal Capacity [W] 10166.68304
626 Controller:OutdoorAir SPLIT MS2_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.61321
627 Controller:OutdoorAir SPLIT MS2_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 5.19091E-002
628 AirLoopHVAC:UnitarySystem SPLIT MS2_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.61321
629 AirLoopHVAC:UnitarySystem SPLIT MS2_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.61321
630 AirLoopHVAC:UnitarySystem SPLIT MS2_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.61321
631 AirLoopHVAC:UnitarySystem SPLIT MS2_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.61321
632 AirLoopHVAC:UnitarySystem SPLIT MS2_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 10150.75826
633 AirLoopHVAC:UnitarySystem SPLIT MS2_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 6801.00803
634 AirLoopHVAC:UnitarySystem SPLIT MS2_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
635 AirLoopHVAC:UnitarySystem SPLIT MS2_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 10150.75826
636 AirLoopHVAC:UnitarySystem SPLIT MS2_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
637 Fan:OnOff SPLIT MS2 SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.61321
638 Coil:Cooling:DX:SingleSpeed SPLIT MS2 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.61321
639 Coil:Cooling:DX:SingleSpeed SPLIT MS2 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 10150.75826
640 Coil:Cooling:DX:SingleSpeed SPLIT MS2 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
641 Coil:Heating:DX:SingleSpeed SPLIT MS2 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.61321
642 Coil:Heating:DX:SingleSpeed SPLIT MS2 HEATING COIL Design Size Gross Rated Heating Capacity [W] 10150.75826
643 Coil:Heating:Electric SPLIT MS2_SUPPHEATCOIL Design Size Nominal Capacity [W] 10150.75826
644 Controller:OutdoorAir SPLIT TSW_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.44993
645 Controller:OutdoorAir SPLIT TSW_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.59546E-002
646 AirLoopHVAC:UnitarySystem SPLIT TSW_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.44993
647 AirLoopHVAC:UnitarySystem SPLIT TSW_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.44993
648 AirLoopHVAC:UnitarySystem SPLIT TSW_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.44993
649 AirLoopHVAC:UnitarySystem SPLIT TSW_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.44993
650 AirLoopHVAC:UnitarySystem SPLIT TSW_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 7447.88038
651 AirLoopHVAC:UnitarySystem SPLIT TSW_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 4990.07986
652 AirLoopHVAC:UnitarySystem SPLIT TSW_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
653 AirLoopHVAC:UnitarySystem SPLIT TSW_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 7447.88038
654 AirLoopHVAC:UnitarySystem SPLIT TSW_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
655 Fan:OnOff SPLIT TSW SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.44993
656 Coil:Cooling:DX:SingleSpeed SPLIT TSW HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.44993
657 Coil:Cooling:DX:SingleSpeed SPLIT TSW HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 7447.88038
658 Coil:Cooling:DX:SingleSpeed SPLIT TSW HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
659 Coil:Heating:DX:SingleSpeed SPLIT TSW HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.44993
660 Coil:Heating:DX:SingleSpeed SPLIT TSW HEATING COIL Design Size Gross Rated Heating Capacity [W] 7447.88038
661 Coil:Heating:Electric SPLIT TSW_SUPPHEATCOIL Design Size Nominal Capacity [W] 7447.88038
662 Controller:OutdoorAir SPLIT TNW_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.44890
663 Controller:OutdoorAir SPLIT TNW_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.59546E-002
664 AirLoopHVAC:UnitarySystem SPLIT TNW_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.44890
665 AirLoopHVAC:UnitarySystem SPLIT TNW_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.44890
666 AirLoopHVAC:UnitarySystem SPLIT TNW_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.44890
667 AirLoopHVAC:UnitarySystem SPLIT TNW_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.44890
668 AirLoopHVAC:UnitarySystem SPLIT TNW_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 7430.92249
669 AirLoopHVAC:UnitarySystem SPLIT TNW_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 4978.71807
670 AirLoopHVAC:UnitarySystem SPLIT TNW_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
671 AirLoopHVAC:UnitarySystem SPLIT TNW_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 7430.92249
672 AirLoopHVAC:UnitarySystem SPLIT TNW_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
673 Fan:OnOff SPLIT TNW SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.44890
674 Coil:Cooling:DX:SingleSpeed SPLIT TNW HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.44890
675 Coil:Cooling:DX:SingleSpeed SPLIT TNW HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 7430.92249
676 Coil:Cooling:DX:SingleSpeed SPLIT TNW HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
677 Coil:Heating:DX:SingleSpeed SPLIT TNW HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.44890
678 Coil:Heating:DX:SingleSpeed SPLIT TNW HEATING COIL Design Size Gross Rated Heating Capacity [W] 7430.92249
679 Coil:Heating:Electric SPLIT TNW_SUPPHEATCOIL Design Size Nominal Capacity [W] 7430.92249
680 Controller:OutdoorAir SPLIT TSE_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.40313
681 Controller:OutdoorAir SPLIT TSE_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.59546E-002
682 AirLoopHVAC:UnitarySystem SPLIT TSE_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.40313
683 AirLoopHVAC:UnitarySystem SPLIT TSE_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.40313
684 AirLoopHVAC:UnitarySystem SPLIT TSE_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.40313
685 AirLoopHVAC:UnitarySystem SPLIT TSE_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.40313
686 AirLoopHVAC:UnitarySystem SPLIT TSE_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 6673.20320
687 AirLoopHVAC:UnitarySystem SPLIT TSE_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 4471.04614
688 AirLoopHVAC:UnitarySystem SPLIT TSE_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
689 AirLoopHVAC:UnitarySystem SPLIT TSE_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 6673.20320
690 AirLoopHVAC:UnitarySystem SPLIT TSE_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
691 Fan:OnOff SPLIT TSE SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.40313
692 Coil:Cooling:DX:SingleSpeed SPLIT TSE HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.40313
693 Coil:Cooling:DX:SingleSpeed SPLIT TSE HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 6673.20320
694 Coil:Cooling:DX:SingleSpeed SPLIT TSE HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
695 Coil:Heating:DX:SingleSpeed SPLIT TSE HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.40313
696 Coil:Heating:DX:SingleSpeed SPLIT TSE HEATING COIL Design Size Gross Rated Heating Capacity [W] 6673.20320
697 Coil:Heating:Electric SPLIT TSE_SUPPHEATCOIL Design Size Nominal Capacity [W] 6673.20320
698 Controller:OutdoorAir SPLIT TNE_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.40204
699 Controller:OutdoorAir SPLIT TNE_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.59546E-002
700 AirLoopHVAC:UnitarySystem SPLIT TNE_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.40204
701 AirLoopHVAC:UnitarySystem SPLIT TNE_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.40204
702 AirLoopHVAC:UnitarySystem SPLIT TNE_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.40204
703 AirLoopHVAC:UnitarySystem SPLIT TNE_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.40204
704 AirLoopHVAC:UnitarySystem SPLIT TNE_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 6655.22744
705 AirLoopHVAC:UnitarySystem SPLIT TNE_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 4459.00238
706 AirLoopHVAC:UnitarySystem SPLIT TNE_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
707 AirLoopHVAC:UnitarySystem SPLIT TNE_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 6655.22744
708 AirLoopHVAC:UnitarySystem SPLIT TNE_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
709 Fan:OnOff SPLIT TNE SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.40204
710 Coil:Cooling:DX:SingleSpeed SPLIT TNE HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.40204
711 Coil:Cooling:DX:SingleSpeed SPLIT TNE HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 6655.22744
712 Coil:Cooling:DX:SingleSpeed SPLIT TNE HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
713 Coil:Heating:DX:SingleSpeed SPLIT TNE HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.40204
714 Coil:Heating:DX:SingleSpeed SPLIT TNE HEATING COIL Design Size Gross Rated Heating Capacity [W] 6655.22744
715 Coil:Heating:Electric SPLIT TNE_SUPPHEATCOIL Design Size Nominal Capacity [W] 6655.22744
716 Controller:OutdoorAir SPLIT TN1_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.36109
717 Controller:OutdoorAir SPLIT TN1_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.59546E-002
718 AirLoopHVAC:UnitarySystem SPLIT TN1_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.36109
719 AirLoopHVAC:UnitarySystem SPLIT TN1_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.36109
720 AirLoopHVAC:UnitarySystem SPLIT TN1_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.36109
721 AirLoopHVAC:UnitarySystem SPLIT TN1_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.36109
722 AirLoopHVAC:UnitarySystem SPLIT TN1_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 5977.34081
723 AirLoopHVAC:UnitarySystem SPLIT TN1_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 4004.81835
724 AirLoopHVAC:UnitarySystem SPLIT TN1_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
725 AirLoopHVAC:UnitarySystem SPLIT TN1_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 5977.34081
726 AirLoopHVAC:UnitarySystem SPLIT TN1_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
727 Fan:OnOff SPLIT TN1 SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.36109
728 Coil:Cooling:DX:SingleSpeed SPLIT TN1 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.36109
729 Coil:Cooling:DX:SingleSpeed SPLIT TN1 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 5977.34081
730 Coil:Cooling:DX:SingleSpeed SPLIT TN1 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
731 Coil:Heating:DX:SingleSpeed SPLIT TN1 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.36109
732 Coil:Heating:DX:SingleSpeed SPLIT TN1 HEATING COIL Design Size Gross Rated Heating Capacity [W] 5977.34081
733 Coil:Heating:Electric SPLIT TN1_SUPPHEATCOIL Design Size Nominal Capacity [W] 5977.34081
734 Controller:OutdoorAir SPLIT TN2_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.35964
735 Controller:OutdoorAir SPLIT TN2_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.59546E-002
736 AirLoopHVAC:UnitarySystem SPLIT TN2_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.35964
737 AirLoopHVAC:UnitarySystem SPLIT TN2_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.35964
738 AirLoopHVAC:UnitarySystem SPLIT TN2_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.35964
739 AirLoopHVAC:UnitarySystem SPLIT TN2_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.35964
740 AirLoopHVAC:UnitarySystem SPLIT TN2_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 5953.30787
741 AirLoopHVAC:UnitarySystem SPLIT TN2_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 3988.71628
742 AirLoopHVAC:UnitarySystem SPLIT TN2_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
743 AirLoopHVAC:UnitarySystem SPLIT TN2_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 5953.30787
744 AirLoopHVAC:UnitarySystem SPLIT TN2_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
745 Fan:OnOff SPLIT TN2 SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.35964
746 Coil:Cooling:DX:SingleSpeed SPLIT TN2 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.35964
747 Coil:Cooling:DX:SingleSpeed SPLIT TN2 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 5953.30787
748 Coil:Cooling:DX:SingleSpeed SPLIT TN2 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
749 Coil:Heating:DX:SingleSpeed SPLIT TN2 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.35964
750 Coil:Heating:DX:SingleSpeed SPLIT TN2 HEATING COIL Design Size Gross Rated Heating Capacity [W] 5953.30787
751 Coil:Heating:Electric SPLIT TN2_SUPPHEATCOIL Design Size Nominal Capacity [W] 5953.30787
752 Controller:OutdoorAir SPLIT TS1_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.36288
753 Controller:OutdoorAir SPLIT TS1_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.59546E-002
754 AirLoopHVAC:UnitarySystem SPLIT TS1_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.36288
755 AirLoopHVAC:UnitarySystem SPLIT TS1_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.36288
756 AirLoopHVAC:UnitarySystem SPLIT TS1_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.36288
757 AirLoopHVAC:UnitarySystem SPLIT TS1_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.36288
758 AirLoopHVAC:UnitarySystem SPLIT TS1_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 6006.98251
759 AirLoopHVAC:UnitarySystem SPLIT TS1_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 4024.67828
760 AirLoopHVAC:UnitarySystem SPLIT TS1_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
761 AirLoopHVAC:UnitarySystem SPLIT TS1_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 6006.98251
762 AirLoopHVAC:UnitarySystem SPLIT TS1_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
763 Fan:OnOff SPLIT TS1 SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.36288
764 Coil:Cooling:DX:SingleSpeed SPLIT TS1 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.36288
765 Coil:Cooling:DX:SingleSpeed SPLIT TS1 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 6006.98251
766 Coil:Cooling:DX:SingleSpeed SPLIT TS1 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
767 Coil:Heating:DX:SingleSpeed SPLIT TS1 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.36288
768 Coil:Heating:DX:SingleSpeed SPLIT TS1 HEATING COIL Design Size Gross Rated Heating Capacity [W] 6006.98251
769 Coil:Heating:Electric SPLIT TS1_SUPPHEATCOIL Design Size Nominal Capacity [W] 6006.98251
770 Controller:OutdoorAir SPLIT TS2_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.36143
771 Controller:OutdoorAir SPLIT TS2_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.59546E-002
772 AirLoopHVAC:UnitarySystem SPLIT TS2_UNITARY_PACKAGE_DX Design Size Supply Air Flow Rate [m3/s] 0.36143
773 AirLoopHVAC:UnitarySystem SPLIT TS2_UNITARY_PACKAGE_DX Design Size Heating Supply Air Flow Rate [m3/s] 0.36143
774 AirLoopHVAC:UnitarySystem SPLIT TS2_UNITARY_PACKAGE_DX Design Size Cooling Supply Air Flow Rate [m3/s] 0.36143
775 AirLoopHVAC:UnitarySystem SPLIT TS2_UNITARY_PACKAGE_DX Design Size No Load Supply Air Flow Rate [m3/s] 0.36143
776 AirLoopHVAC:UnitarySystem SPLIT TS2_UNITARY_PACKAGE_DX Design Size Nominal Cooling Capacity [W] 5983.02238
777 AirLoopHVAC:UnitarySystem SPLIT TS2_UNITARY_PACKAGE_DX Design Size Nominal Heating Capacity [W] 4008.62499
778 AirLoopHVAC:UnitarySystem SPLIT TS2_UNITARY_PACKAGE_DX Design Size Maximum Supply Air Temperature [C] 40.00000
779 AirLoopHVAC:UnitarySystem SPLIT TS2_UNITARY_PACKAGE_DX User-Specified Supplemental Heating Coil Nominal Capacity [W] 5983.02238
780 AirLoopHVAC:UnitarySystem SPLIT TS2_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
781 Fan:OnOff SPLIT TS2 SUPPLY FAN Design Size Maximum Flow Rate [m3/s] 0.36143
782 Coil:Cooling:DX:SingleSpeed SPLIT TS2 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.36143
783 Coil:Cooling:DX:SingleSpeed SPLIT TS2 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 5983.02238
784 Coil:Cooling:DX:SingleSpeed SPLIT TS2 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
785 Coil:Heating:DX:SingleSpeed SPLIT TS2 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.36143
786 Coil:Heating:DX:SingleSpeed SPLIT TS2 HEATING COIL Design Size Gross Rated Heating Capacity [W] 5983.02238
787 Coil:Heating:Electric SPLIT TS2_SUPPHEATCOIL Design Size Nominal Capacity [W] 5983.02238
788 PlantLoop SWHSYS1 Maximum Loop Flow Rate [m3/s] 1.01206E-004
789 PlantLoop SWHSYS1 Plant Loop Volume [m3] 1.21448E-002
790 Pump:ConstantSpeed SWHSYS1 PUMP Design Flow Rate [m3/s] 1.01206E-004
791 Pump:ConstantSpeed SWHSYS1 PUMP Design Power Consumption [W] 12.92803
792 WaterHeater:Mixed SWHSYS1 WATER HEATER Use Side Design Flow Rate [m3/s] 1.01206E-004


DX Cooling Coil Standard Rating Information

Component Type Component Name Standard Rating (Net) Cooling Capacity {W} Standard Rated Net COP {W/W} EER {Btu/W-h} SEER User {Btu/W-h} SEER Standard {Btu/W-h} IEER {Btu/W-h}
1 Coil:Cooling:DX:SingleSpeed SPLIT GSW HP COOLING COIL 5392.4 3.20 10.91 11.33 10.72 10.58
2 Coil:Cooling:DX:SingleSpeed SPLIT GNW HP COOLING COIL 5302.3 3.20 10.91 11.33 10.72 10.58
3 Coil:Cooling:DX:SingleSpeed SPLIT OFFICE HP COOLING COIL 6450.6 3.20 10.91 11.33 10.72 10.58
4 Coil:Cooling:DX:SingleSpeed SPLIT GNE HP COOLING COIL 4926.3 3.20 10.91 11.33 10.72 10.58
5 Coil:Cooling:DX:SingleSpeed SPLIT GN1 HP COOLING COIL 4224.1 3.20 10.91 11.33 10.72 10.58
6 Coil:Cooling:DX:SingleSpeed SPLIT GN2 HP COOLING COIL 4217.4 3.20 10.91 11.33 10.72 10.58
7 Coil:Cooling:DX:SingleSpeed SPLIT GS1 HP COOLING COIL 4307.7 3.20 10.91 11.33 10.72 10.58
8 Coil:Cooling:DX:SingleSpeed SPLIT GS2 HP COOLING COIL 4399.0 3.20 10.91 11.33 10.72 10.58
9 Coil:Cooling:DX:SingleSpeed SPLIT MSW HP COOLING COIL 12276.8 3.20 10.91 11.33 10.72 10.58
10 Coil:Cooling:DX:SingleSpeed SPLIT MNW HP COOLING COIL 12107.3 3.20 10.91 11.33 10.72 10.58
11 Coil:Cooling:DX:SingleSpeed SPLIT MSE HP COOLING COIL 11274.1 3.20 10.91 11.33 10.72 10.58
12 Coil:Cooling:DX:SingleSpeed SPLIT MNE HP COOLING COIL 11106.9 3.20 10.91 11.33 10.72 10.58
13 Coil:Cooling:DX:SingleSpeed SPLIT MN1 HP COOLING COIL 9523.1 3.20 10.91 11.33 10.72 10.58
14 Coil:Cooling:DX:SingleSpeed SPLIT MN2 HP COOLING COIL 9506.3 3.20 10.91 11.33 10.72 10.58
15 Coil:Cooling:DX:SingleSpeed SPLIT MS1 HP COOLING COIL 9685.4 3.20 10.91 11.33 10.72 10.58
16 Coil:Cooling:DX:SingleSpeed SPLIT MS2 HP COOLING COIL 9670.2 3.20 10.91 11.33 10.72 10.58
17 Coil:Cooling:DX:SingleSpeed SPLIT TSW HP COOLING COIL 7095.3 3.20 10.91 11.33 10.72 10.58
18 Coil:Cooling:DX:SingleSpeed SPLIT TNW HP COOLING COIL 7079.1 3.20 10.91 11.33 10.72 10.58
19 Coil:Cooling:DX:SingleSpeed SPLIT TSE HP COOLING COIL 6357.3 3.20 10.91 11.33 10.72 10.58
20 Coil:Cooling:DX:SingleSpeed SPLIT TNE HP COOLING COIL 6340.2 3.20 10.91 11.33 10.72 10.58
21 Coil:Cooling:DX:SingleSpeed SPLIT TN1 HP COOLING COIL 5694.4 3.20 10.91 11.33 10.72 10.58
22 Coil:Cooling:DX:SingleSpeed SPLIT TN2 HP COOLING COIL 5671.5 3.20 10.91 11.33 10.72 10.58
23 Coil:Cooling:DX:SingleSpeed SPLIT TS1 HP COOLING COIL 5722.6 3.20 10.91 11.33 10.72 10.58
24 Coil:Cooling:DX:SingleSpeed SPLIT TS2 HP COOLING COIL 5699.8 3.20 10.91 11.33 10.72 10.58


DX Heating Coil Standard Rating Information

Component Type Component Name High Temperature Heating (net) Rating Capacity {W} Low Temperature Heating (net) Rating Capacity {W} HSPF {Btu/W-h} Region Number
1 Coil:Heating:DX:SingleSpeed SPLIT GSW HEATING COIL 5931.6 3303.6 8.06 4
2 Coil:Heating:DX:SingleSpeed SPLIT GNW HEATING COIL 5832.5 3248.4 8.05 4
3 Coil:Heating:DX:SingleSpeed SPLIT OFFICE HEATING COIL 7095.7 3951.9 8.04 4
4 Coil:Heating:DX:SingleSpeed SPLIT GNE HEATING COIL 5418.9 3018.0 8.02 4
5 Coil:Heating:DX:SingleSpeed SPLIT GN1 HEATING COIL 4646.5 2587.8 8.08 4
6 Coil:Heating:DX:SingleSpeed SPLIT GN2 HEATING COIL 4639.2 2583.7 8.08 4
7 Coil:Heating:DX:SingleSpeed SPLIT GS1 HEATING COIL 4738.5 2639.1 8.09 4
8 Coil:Heating:DX:SingleSpeed SPLIT GS2 HEATING COIL 4838.9 2695.0 8.10 4
9 Coil:Heating:DX:SingleSpeed SPLIT MSW HEATING COIL 13504.5 7521.2 8.02 4
10 Coil:Heating:DX:SingleSpeed SPLIT MNW HEATING COIL 13318.1 7417.4 8.02 4
11 Coil:Heating:DX:SingleSpeed SPLIT MSE HEATING COIL 12401.6 6906.9 8.08 4
12 Coil:Heating:DX:SingleSpeed SPLIT MNE HEATING COIL 12217.7 6804.5 8.07 4
13 Coil:Heating:DX:SingleSpeed SPLIT MN1 HEATING COIL 10475.5 5834.2 8.06 4
14 Coil:Heating:DX:SingleSpeed SPLIT MN2 HEATING COIL 10457.0 5823.9 8.06 4
15 Coil:Heating:DX:SingleSpeed SPLIT MS1 HEATING COIL 10653.9 5933.6 8.07 4
16 Coil:Heating:DX:SingleSpeed SPLIT MS2 HEATING COIL 10637.3 5924.3 8.07 4
17 Coil:Heating:DX:SingleSpeed SPLIT TSW HEATING COIL 7804.8 4346.8 8.08 4
18 Coil:Heating:DX:SingleSpeed SPLIT TNW HEATING COIL 7787.1 4336.9 8.08 4
19 Coil:Heating:DX:SingleSpeed SPLIT TSE HEATING COIL 6993.0 3894.7 8.03 4
20 Coil:Heating:DX:SingleSpeed SPLIT TNE HEATING COIL 6974.2 3884.2 8.03 4
21 Coil:Heating:DX:SingleSpeed SPLIT TN1 HEATING COIL 6263.8 3488.6 8.08 4
22 Coil:Heating:DX:SingleSpeed SPLIT TN2 HEATING COIL 6238.6 3474.5 8.08 4
23 Coil:Heating:DX:SingleSpeed SPLIT TS1 HEATING COIL 6294.9 3505.9 8.09 4
24 Coil:Heating:DX:SingleSpeed SPLIT TS2 HEATING COIL 6269.8 3491.9 8.08 4


Zone Surfaces

Zone Name # Surfaces
1 G SW APARTMENT 9
2 G NW APARTMENT 9
3 OFFICE 9
4 G NE APARTMENT 9
5 G N1 APARTMENT 8
6 G N2 APARTMENT 8
7 G S1 APARTMENT 8
8 G S2 APARTMENT 8
9 M SW APARTMENT 9
10 M NW APARTMENT 9
11 M SE APARTMENT 9
12 M NE APARTMENT 9
13 M N1 APARTMENT 8
14 M N2 APARTMENT 8
15 M S1 APARTMENT 8
16 M S2 APARTMENT 8
17 T SW APARTMENT 9
18 T NW APARTMENT 9
19 T SE APARTMENT 9
20 T NE APARTMENT 9
21 T N1 APARTMENT 8
22 T N2 APARTMENT 8
23 T S1 APARTMENT 8
24 T S2 APARTMENT 8
25 T CORRIDOR 13
26 G CORRIDOR 13
27 M CORRIDOR 13


HeatTransfer Surface

Surface Name Surface Class Base Surface Heat Transfer Algorithm Construction Nominal U (w/o film coefs) {W/m2-K} Nominal U (with film coefs) {W/m2-K} Solar Diffusing Area (Net) {m2} Area (Gross) {m2} Area (Sunlit Calc) {m2} Azimuth {deg} Tilt {deg} ~Width {m} ~Height {m} Reveal {m} ExtBoundCondition ExtConvCoeffCalc IntConvCoeffCalc SunExposure WindExposure ViewFactorToGround ViewFactorToSky ViewFactorToGround-IR ViewFactorToSky-IR #Sides
1 G SWALL SWA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_GRD 0.712 0.644   28.24 35.30 28.24 180.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
2 GWINDOW1 S SWA Window G SWALL SWA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 180.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
3 G WWALL SWA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_GRD 0.712 0.644   18.58 23.22 18.58 270.00 90.00 7.62 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
4 GWINDOW1 W SWA Window G WWALL SWA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 4.65 4.65 4.65 270.00 90.00 3.81 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
5 G NIWALL SWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 iz-G NIWALL SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
6 G EIWALL SWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-G EIWALL SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
7 G GFLOOR SWA Floor   CTF - ConductionTransferFunction GGFLOORSWA_FFACTOR 0.287 0.268   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
8 G CEILIN SWA Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 G CEILIN SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
9 G INTERNALMASS SWA Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   88.25 88.25 88.25 0.00 90.00 88.25 1.00 0.00 G INTERNALMASS SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
10 G NWALL NWA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_GRD 0.712 0.644   28.24 35.30 28.24 0.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
11 GWINDOW1 N NWA Window G NWALL NWA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 0.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
12 G WWALL NWA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_GRD 0.712 0.644   18.58 23.22 18.58 270.00 90.00 7.62 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
13 GWINDOW1 W NWA Window G WWALL NWA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 4.65 4.65 4.65 270.00 90.00 3.81 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
14 G SIWALL NWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 iz-G SIWALL NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
15 G EIWALL NWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-G EIWALL NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
16 G GFLOOR NWA Floor   CTF - ConductionTransferFunction GGFLOORNWA_FFACTOR 0.287 0.268   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
17 G CEILIN NWA Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 G CEILIN NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
18 G INTERNALMASS NWA Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   88.25 88.25 88.25 0.00 90.00 88.25 1.00 0.00 G INTERNALMASS NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
19 G SWALL SEA Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.854 0.757   28.24 35.30 28.24 180.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
20 GWINDOW1 S SEA Window G SWALL SEA Window5 Detailed Fenestration NONRESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 180.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
21 G EWALL SEA Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.854 0.757   18.58 23.22 18.58 90.00 90.00 7.62 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
22 GWINDOW1 E SEA Window G EWALL SEA Window5 Detailed Fenestration NONRESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 4.65 4.65 4.65 90.00 90.00 3.81 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
23 G NIWALL SEA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 iz-G NIWALL SEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
24 iz-G EIWALL S2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 G EIWALL S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
25 G GFLOOR SEA Floor   CTF - ConductionTransferFunction GGFLOORSEA_FFACTOR 0.287 0.268   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
26 G CEILIN SEA Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 G CEILIN SEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
27 G INTERNALMASS SEA Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   88.25 88.25 88.25 0.00 90.00 88.25 1.00 0.00 G INTERNALMASS SEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
28 G NWALL NEA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_GRD 0.712 0.644   28.24 35.30 28.24 0.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
29 GWINDOW1 N NEA Window G NWALL NEA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 0.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
30 G EWALL NEA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_GRD 0.712 0.644   18.58 23.22 18.58 90.00 90.00 7.62 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
31 GWINDOW1 E NEA Window G EWALL NEA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 4.65 4.65 4.65 90.00 90.00 3.81 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
32 G SIWALL NEA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 iz-G SIWALL NEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
33 iz-G EIWALL N2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 G EIWALL N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
34 G GFLOOR NEA Floor   CTF - ConductionTransferFunction GGFLOORNEA_FFACTOR 0.287 0.268   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
35 G CEILIN NEA Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 G CEILIN NEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
36 G INTERNALMASS NEA Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   88.25 88.25 88.25 0.00 90.00 88.25 1.00 0.00 G INTERNALMASS NEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
37 G NWALL N1A Wall   CTF - ConductionTransferFunction RES_EXT_WALL_GRD 0.712 0.644   28.24 35.30 28.24 0.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
38 GWINDOW1 N N1A Window G NWALL N1A Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 0.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
39 G SIWALL N1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 iz-G SIWALL N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
40 G EIWALL N1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-G EIWALL N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
41 iz-G EIWALL NWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 G EIWALL NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
42 G GFLOOR N1A Floor   CTF - ConductionTransferFunction GGFLOORN1A_FFACTOR 0.170 0.163   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
43 G CEILIN N1A Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 G CEILIN N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
44 G INTERNALMASS N1A Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   88.25 88.25 88.25 0.00 90.00 88.25 1.00 0.00 G INTERNALMASS N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
45 G NWALL N2A Wall   CTF - ConductionTransferFunction RES_EXT_WALL_GRD 0.712 0.644   28.24 35.30 28.24 0.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
46 GWINDOW1 N N2A Window G NWALL N2A Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 0.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
47 G SIWALL N2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 iz-G SIWALL N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
48 G EIWALL N2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-G EIWALL N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
49 iz-G EIWALL N1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 G EIWALL N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
50 G GFLOOR N2A Floor   CTF - ConductionTransferFunction GGFLOORN2A_FFACTOR 0.170 0.163   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
51 G CEILIN N2A Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 G CEILIN N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
52 G INTERNALMASS N2A Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   88.25 88.25 88.25 0.00 90.00 88.25 1.00 0.00 G INTERNALMASS N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
53 G SWALL S1A Wall   CTF - ConductionTransferFunction RES_EXT_WALL_GRD 0.712 0.644   28.24 35.30 28.24 180.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
54 GWINDOW1 S S1A Window G SWALL S1A Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 180.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
55 G NIWALL S1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 iz-G NIWALL S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
56 G EIWALL S1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-G EIWALL S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
57 iz-G EIWALL SWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 G EIWALL SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
58 G GFLOOR S1A Floor   CTF - ConductionTransferFunction GGFLOORS1A_FFACTOR 0.170 0.163   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
59 G CEILIN S1A Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 G CEILIN S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
60 G INTERNALMASS S1A Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   88.25 88.25 88.25 0.00 90.00 88.25 1.00 0.00 G INTERNALMASS S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
61 G SWALL S2A Wall   CTF - ConductionTransferFunction RES_EXT_WALL_GRD 0.712 0.644   28.24 35.30 28.24 180.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
62 GWINDOW1 S S2A Window G SWALL S2A Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 180.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
63 G NIWALL S2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 iz-G NIWALL S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
64 G EIWALL S2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-G EIWALL S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
65 iz-G EIWALL S1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 G EIWALL S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
66 G GFLOOR S2A Floor   CTF - ConductionTransferFunction GGFLOORS2A_FFACTOR 0.170 0.163   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
67 G CEILIN S2A Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 G CEILIN S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
68 G INTERNALMASS S2A Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   88.25 88.25 88.25 0.00 90.00 88.25 1.00 0.00 G INTERNALMASS S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
69 M WWALL SWA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.727 0.655   18.58 23.22 18.58 270.00 90.00 7.62 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
70 MWINDOW1 W SWA Window M WWALL SWA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 4.65 4.65 4.65 270.00 90.00 3.81 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
71 M SWALL SWA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.727 0.655   28.24 35.30 28.24 180.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
72 MWINDOW1 S SWA Window M SWALL SWA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 180.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
73 M NIWALL SWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 iz-M NIWALL SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
74 M EIWALL SWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 3.05 7.62 0.00 iz-M EIWALL SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
75 M GFLOOR SWA Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 M GFLOOR SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
76 M CEILIN SWA Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 M CEILIN SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
77 M INTERNALMASS SWA Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   176.50 176.50 176.50 0.00 90.00 176.50 1.00 0.00 M INTERNALMASS SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
78 M NWALL NWA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.727 0.655   28.24 35.30 28.24 0.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
79 MWINDOW1 N NWA Window M NWALL NWA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 0.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
80 M WWALL NWA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.727 0.655   18.58 23.22 18.58 270.00 90.00 7.62 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
81 MWINDOW1 W NWA Window M WWALL NWA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 4.65 4.65 4.65 270.00 90.00 3.81 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
82 M SIWALL NWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 iz-M SIWALL NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
83 M EIWALL NWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-M EIWALL NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
84 M GFLOOR NWA Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 M GFLOOR NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
85 M CEILIN NWA Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 M CEILIN NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
86 M INTERNALMASS NWA Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   176.50 176.50 176.50 0.00 90.00 176.50 1.00 0.00 M INTERNALMASS NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
87 M EWALL SEA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.727 0.655   18.58 23.22 18.58 90.00 90.00 7.62 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
88 MWINDOW1 E SEA Window M EWALL SEA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 4.65 4.65 4.65 90.00 90.00 3.81 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
89 M SWALL SEA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.727 0.655   28.24 35.30 28.24 180.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
90 MWINDOW1 S SEA Window M SWALL SEA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 180.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
91 M NIWALL SEA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 iz-M NIWALL SEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
92 iz-M EIWALL S2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 M EIWALL S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
93 M GFLOOR SEA Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 M GFLOOR SEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
94 M CEILIN SEA Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 M CEILIN SEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
95 M INTERNALMASS SEA Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   176.50 176.50 176.50 0.00 90.00 176.50 1.00 0.00 M INTERNALMASS SEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
96 M NWALL NEA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.727 0.655   28.24 35.30 28.24 0.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
97 MWINDOW1 N NEA Window M NWALL NEA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 0.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
98 M EWALL NEA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.727 0.655   18.58 23.22 18.58 90.00 90.00 7.62 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
99 MWINDOW1 E NEA Window M EWALL NEA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 4.65 4.65 4.65 90.00 90.00 3.81 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
100 M SIWALL NEA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 iz-M SIWALL NEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
101 iz-M EIWALL N2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 M EIWALL N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
102 M GFLOOR NEA Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 M GFLOOR NEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
103 M CEILIN NEA Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 M CEILIN NEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
104 M INTERNALMASS NEA Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   176.50 176.50 176.50 0.00 90.00 176.50 1.00 0.00 M INTERNALMASS NEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
105 M NWALL N1A Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.727 0.655   28.24 35.30 28.24 0.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
106 MWINDOW1 N N1A Window M NWALL N1A Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 0.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
107 M SIWALL N1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 iz-M SIWALL N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
108 M EIWALL N1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-M EIWALL N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
109 iz-M EIWALL NWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 M EIWALL NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
110 M GFLOOR N1A Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 M GFLOOR N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
111 M CEILIN N1A Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 M CEILIN N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
112 M INTERNALMASS N1A Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   176.50 176.50 176.50 0.00 90.00 176.50 1.00 0.00 M INTERNALMASS N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
113 M NWALL N2A Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.727 0.655   28.24 35.30 28.24 0.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
114 MWINDOW1 N N2A Window M NWALL N2A Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 0.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
115 M SIWALL N2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 iz-M SIWALL N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
116 M EIWALL N2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-M EIWALL N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
117 iz-M EIWALL N1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 M EIWALL N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
118 M GFLOOR N2A Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 M GFLOOR N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
119 M CEILIN N2A Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 M CEILIN N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
120 M INTERNALMASS N2A Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   176.50 176.50 176.50 0.00 90.00 176.50 1.00 0.00 M INTERNALMASS N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
121 M SWALL S1A Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.727 0.655   28.24 35.30 28.24 180.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
122 MWINDOW1 S S1A Window M SWALL S1A Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 180.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
123 M NIWALL S1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 iz-M NIWALL S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
124 M EIWALL S1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-M EIWALL S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
125 iz-M EIWALL SWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 3.05 7.62 0.00 M EIWALL SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
126 M GFLOOR S1A Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 M GFLOOR S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
127 M CEILIN S1A Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 M CEILIN S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
128 M INTERNALMASS S1A Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   176.50 176.50 176.50 0.00 90.00 176.50 1.00 0.00 M INTERNALMASS S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
129 M SWALL S2A Wall   CTF - ConductionTransferFunction RES_EXT_WALL_MID 0.727 0.655   28.24 35.30 28.24 180.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
130 MWINDOW1 S S2A Window M SWALL S2A Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 180.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
131 M NIWALL S2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 iz-M NIWALL S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
132 M EIWALL S2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-M EIWALL S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
133 iz-M EIWALL S1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 M EIWALL S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
134 M GFLOOR S2A Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 M GFLOOR S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
135 M CEILIN S2A Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 M CEILIN S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
136 M INTERNALMASS S2A Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   176.50 176.50 176.50 0.00 90.00 176.50 1.00 0.00 M INTERNALMASS S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
137 T WWALL SWA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.957 0.837   18.58 23.22 18.58 270.00 90.00 7.62 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
138 TWINDOW1 W SWA Window T WWALL SWA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 4.65 4.65 4.65 270.00 90.00 3.81 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
139 T SWALL SWA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.957 0.837   28.24 35.30 28.24 180.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
140 TWINDOW1 S SWA Window T SWALL SWA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 180.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
141 T NIWALL SWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 iz-T NIWALL SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
142 T EIWALL SWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-T EIWALL SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
143 T GFLOOR SWA Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 T GFLOOR SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
144 T ROOF SWA Roof   CTF - ConductionTransferFunction RES_ROOF 0.228 0.219   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 4
145 T INTERNALMASS SWA Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   88.25 88.25 88.25 0.00 90.00 88.25 1.00 0.00 T INTERNALMASS SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
146 T NWALL NWA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.957 0.837   28.24 35.30 28.24 0.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
147 TWINDOW1 N NWA Window T NWALL NWA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 0.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
148 T WWALL NWA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.957 0.837   18.58 23.22 18.58 270.00 90.00 7.62 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
149 TWINDOW1 W NWA Window T WWALL NWA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 4.65 4.65 4.65 270.00 90.00 3.81 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
150 T SIWALL NWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 iz-T SIWALL NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
151 T EIWALL NWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-T EIWALL NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
152 T GFLOOR NWA Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 T GFLOOR NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
153 T ROOF NWA Roof   CTF - ConductionTransferFunction RES_ROOF 0.228 0.219   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 4
154 T INTERNALMASS NWA Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   88.25 88.25 88.25 0.00 90.00 88.25 1.00 0.00 T INTERNALMASS NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
155 T EWALL SEA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.957 0.837   18.58 23.22 18.58 90.00 90.00 7.62 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
156 TWINDOW1 E SEA Window T EWALL SEA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 4.65 4.65 4.65 90.00 90.00 3.81 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
157 T SWALL SEA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.957 0.837   28.24 35.30 28.24 180.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
158 TWINDOW1 S SEA Window T SWALL SEA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 180.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
159 T NIWALL SEA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 iz-T NIWALL SEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
160 iz-T EIWALL S2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 T EIWALL S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
161 T GFLOOR SEA Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 T GFLOOR SEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
162 T ROOF SEA Roof   CTF - ConductionTransferFunction RES_ROOF 0.228 0.219   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 4
163 T INTERNALMASS SEA Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   88.25 88.25 88.25 0.00 90.00 88.25 1.00 0.00 T INTERNALMASS SEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
164 T NWALL NEA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.957 0.837   28.24 35.30 28.24 0.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
165 TWINDOW1 N NEA Window T NWALL NEA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 0.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
166 T EWALL NEA Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.957 0.837   18.58 23.22 18.58 90.00 90.00 7.62 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
167 TWINDOW1 E NEA Window T EWALL NEA Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 4.65 4.65 4.65 90.00 90.00 3.81 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
168 T SIWALL NEA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 iz-T SIWALL NEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
169 iz-T EIWALL N2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 T EIWALL N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
170 T GFLOOR NEA Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 T GFLOOR NEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
171 T ROOF NEA Roof   CTF - ConductionTransferFunction RES_ROOF 0.228 0.219   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 4
172 T INTERNALMASS NEA Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   88.25 88.25 88.25 0.00 90.00 88.25 1.00 0.00 T INTERNALMASS NEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
173 T NWALL N1A Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.957 0.837   28.24 35.30 28.24 0.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
174 TWINDOW1 N N1A Window T NWALL N1A Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 0.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
175 T SIWALL N1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 iz-T SIWALL N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
176 T EIWALL N1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-T EIWALL N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
177 iz-T EIWALL NWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 T EIWALL NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
178 T GFLOOR N1A Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 T GFLOOR N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
179 T ROOF N1A Roof   CTF - ConductionTransferFunction RES_ROOF 0.228 0.219   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 4
180 T INTERNALMASS N1A Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   88.25 88.25 88.25 0.00 90.00 88.25 1.00 0.00 T INTERNALMASS N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
181 T NWALL N2A Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.957 0.837   28.24 35.30 28.24 0.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
182 TWINDOW1 N N2A Window T NWALL N2A Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 0.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
183 T SIWALL N2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 iz-T SIWALL N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
184 T EIWALL N2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-T EIWALL N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
185 iz-T EIWALL N1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 T EIWALL N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
186 T GFLOOR N2A Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 T GFLOOR N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
187 T ROOF N2A Roof   CTF - ConductionTransferFunction RES_ROOF 0.228 0.219   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 4
188 T INTERNALMASS N2A Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   88.25 88.25 88.25 0.00 90.00 88.25 1.00 0.00 T INTERNALMASS N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
189 T SWALL S1A Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.957 0.837   28.24 35.30 28.24 180.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
190 TWINDOW1 S S1A Window T SWALL S1A Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 180.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
191 T NIWALL S1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 iz-T NIWALL S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
192 T EIWALL S1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-T EIWALL S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
193 iz-T EIWALL SWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 T EIWALL SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
194 T GFLOOR S1A Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 T GFLOOR S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
195 T ROOF S1A Roof   CTF - ConductionTransferFunction RES_ROOF 0.228 0.219   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 4
196 T INTERNALMASS S1A Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   88.25 88.25 88.25 0.00 90.00 88.25 1.00 0.00 T INTERNALMASS S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
197 T SWALL S2A Wall   CTF - ConductionTransferFunction RES_EXT_WALL_TOP 0.957 0.837   28.24 35.30 28.24 180.00 90.00 11.58 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
198 TWINDOW1 S S2A Window T SWALL S2A Window5 Detailed Fenestration RESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 7.06 7.06 7.06 180.00 90.00 5.79 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
199 T NIWALL S2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 iz-T NIWALL S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
200 T EIWALL S2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 90.00 90.00 7.62 3.05 0.00 iz-T EIWALL S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
201 iz-T EIWALL S1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   23.22 23.22 23.22 270.00 90.00 7.62 3.05 0.00 T EIWALL S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
202 T GFLOOR S2A Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   88.25 88.25 88.25 90.00 180.00 7.62 11.58 0.00 T GFLOOR S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
203 T ROOF S2A Roof   CTF - ConductionTransferFunction RES_ROOF 0.228 0.219   88.25 88.25 88.25 180.00 0.00 11.58 7.62 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.00 1.00 0.00 1.00 4
204 T INTERNALMASS S2A Internal Mass   CTF - ConductionTransferFunction INTERIORFURNISHINGS 0.800 0.800   88.25 88.25 88.25 0.00 90.00 88.25 1.00 0.00 T INTERNALMASS S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 0.50 1.00 0.00 0
205 T WWALL C Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 1.109 0.951   5.11 5.11 5.11 270.00 90.00 1.68 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
206 T EWALL C Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_TOP 1.109 0.951   3.99 5.11 3.99 90.00 90.00 1.68 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
207 TWINDOW14 Window T EWALL C Window5 Detailed Fenestration NONRESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 1.11 1.11 1.11 90.00 90.00 0.91 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
208 iz-T NIWALL SWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 T NIWALL SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
209 iz-T NIWALL S1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 T NIWALL S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
210 iz-T NIWALL S2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 T NIWALL S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
211 iz-T NIWALL SEA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 T NIWALL SEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
212 iz-T SIWALL NWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 T SIWALL NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
213 iz-T SIWALL N1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 T SIWALL N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
214 iz-T SIWALL N2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 T SIWALL N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
215 iz-T SIWALL NEA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 T SIWALL NEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
216 T FLOOR C Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   77.66 77.66 77.66 90.00 180.00 1.68 46.33 0.00 T FLOOR C Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
217 T ROOF C Roof   CTF - ConductionTransferFunction NONRES_ROOF 0.228 0.219   77.66 77.66 77.66 180.00 0.00 46.33 1.68 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
218 G WWALL C Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.854 0.757   5.11 5.11 5.11 270.00 90.00 1.68 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
219 G EWALL C Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_GRD 0.854 0.757   1.79 5.11 1.79 90.00 90.00 1.68 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
220 ENTRANCE DOOR Window G EWALL C Window5 Detailed Fenestration NONRESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 3.32 3.32 3.32 90.00 90.00 1.57 2.11 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
221 iz-G NIWALL SWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 G NIWALL SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
222 iz-G NIWALL S1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 G NIWALL S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
223 iz-G NIWALL S2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 G NIWALL S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
224 iz-G NIWALL SEA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 G NIWALL SEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
225 iz-G SIWALL NWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 G SIWALL NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
226 iz-G SIWALL N1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 G SIWALL N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
227 iz-G SIWALL N2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 G SIWALL N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
228 iz-G SIWALL NEA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 G SIWALL NEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
229 G FLOOR C Floor   CTF - ConductionTransferFunction GFLOORC_FFACTOR 5.502E-002 5.429E-002   77.66 77.66 77.66 90.00 180.00 1.68 46.33 0.00 FCGround N/A-FCGround ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
230 G CEILING C Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   77.66 77.66 77.66 180.00 0.00 46.33 1.68 0.00 G CEILING C Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4
231 M WWALL C Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_MID 0.869 0.769   5.11 5.11 5.11 270.00 90.00 1.68 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
232 M EWALL C Wall   CTF - ConductionTransferFunction NONRES_EXT_WALL_MID 0.869 0.769   3.99 5.11 3.99 90.00 90.00 1.68 3.05 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
233 MWINDOW14 Window M EWALL C Window5 Detailed Fenestration NONRESWINDOW_U_0.487_SHGC_0.245 N/A 2.769 No 1.11 1.11 1.11 90.00 90.00 0.91 1.22 0.00 ExternalEnvironment ASHRAETARP ASHRAETARP SunExposed WindExposed 0.50 0.50 0.50 0.50 4
234 iz-M NIWALL SWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 M NIWALL SWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
235 iz-M NIWALL S1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 M NIWALL S1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
236 iz-M NIWALL S2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 M NIWALL S2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
237 iz-M NIWALL SEA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 180.00 90.00 11.58 3.05 0.00 M NIWALL SEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
238 iz-M SIWALL NWA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 M SIWALL NWA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
239 iz-M SIWALL N1A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 M SIWALL N1A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
240 iz-M SIWALL N2A Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 M SIWALL N2A Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
241 iz-M SIWALL NEA Wall   CTF - ConductionTransferFunction INT_WALL 6.299 3.242   35.30 35.30 35.30 0.00 90.00 11.58 3.05 0.00 M SIWALL NEA Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.50 0.50 0.50 0.50 4
242 M FLOOR C Floor   CTF - ConductionTransferFunction EXT_SLAB_8IN_WITH_CARPET 3.285 1.827   77.66 77.66 77.66 90.00 180.00 1.68 46.33 0.00 M FLOOR C Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 1.00 0.00 1.00 0.00 4
243 M CEILING C Roof   CTF - ConductionTransferFunction INT_SLAB_CEILING 3.839 2.228   77.66 77.66 77.66 180.00 0.00 46.33 1.68 0.00 M CEILING C Other/Same Surface Int Conv ASHRAETARP NoSun NoWind 0.00 1.00 0.00 1.00 4


Environment

Environment Name Environment Type Start Date End Date Start DayOfWeek Duration {#days} Source:Start DayOfWeek Use Daylight Saving Use Holidays Apply Weekend Holiday Rule Use Rain Values Use Snow Values Sky Temperature Model
1 RUNPERIOD 1 WeatherFileRunPeriod 01/01/2017 12/31/2017 Sunday 365 Use RunPeriod Specified Day No No Yes Yes Yes Clark and Allen


Environment:Special Days

Special Day Name Special Day Type Source Start Date Duration {#days}
1 NEW YEAR'S DAY Holiday InputFile 01/02 1Environment:Special Days


Environment:Daylight Saving

Daylight Saving Indicator Source Start Date End Date
1 Yes InputFile 03/12 11/05


Tabular Report

Style Unit Conversion
1 Commaandhtml commaandhtml


Warmup Convergence Information

Zone Name Environment Type/Name Average Warmup Temperature Difference {deltaC} Std Dev Warmup Temperature Difference {deltaC} Max Temperature Pass/Fail Convergence Min Temperature Pass/Fail Convergence Average Warmup Load Difference {W} Std Dev Warmup Load Difference {W} Heating Load Pass/Fail Convergence Cooling Load Pass/Fail Convergence
1 G SW APARTMENT RunPeriod: RUNPERIOD 1 2.1941612548E-002 2.8322654658E-002 Pass Pass 3.7029195690E-002 4.5543479124E-002 Pass Pass
2 G NW APARTMENT RunPeriod: RUNPERIOD 1 1.9791979264E-002 2.2267227375E-002 Pass Pass 0.2741492877 1.6827500109 Pass Pass
3 OFFICE RunPeriod: RUNPERIOD 1 5.1057862084E-002 3.4906772982E-002 Pass Pass 0.1484878280 0.4189564073 Pass Pass
4 G NE APARTMENT RunPeriod: RUNPERIOD 1 1.2572271846E-002 1.6423494038E-002 Pass Pass 0.1353411647 0.6778313135 Pass Pass
5 G N1 APARTMENT RunPeriod: RUNPERIOD 1 1.7212809263E-002 1.6734343364E-002 Pass Pass 2.9396402914E-002 3.0834817614E-002 Pass Pass
6 G N2 APARTMENT RunPeriod: RUNPERIOD 1 1.6992990544E-002 1.6836352198E-002 Pass Pass 2.9506422091E-002 3.1239627361E-002 Pass Pass
7 G S1 APARTMENT RunPeriod: RUNPERIOD 1 9.7098306014E-003 1.8840549629E-002 Pass Pass 2.9996784926E-002 4.3035760663E-002 Pass Pass
8 G S2 APARTMENT RunPeriod: RUNPERIOD 1 1.1373161642E-002 2.0113025385E-002 Pass Pass 3.0149180075E-002 4.2892146555E-002 Pass Pass
9 M SW APARTMENT RunPeriod: RUNPERIOD 1 1.9609968758E-002 2.7206830422E-002 Pass Pass 3.8830620807E-002 5.3677996058E-002 Pass Pass
10 M NW APARTMENT RunPeriod: RUNPERIOD 1 2.6717599795E-002 2.1708407293E-002 Pass Pass 5.2260522991E-002 7.1017041461E-002 Pass Pass
11 M SE APARTMENT RunPeriod: RUNPERIOD 1 2.0372805734E-002 3.2583489962E-002 Pass Pass 3.3415558001E-002 4.4142567470E-002 Pass Pass
12 M NE APARTMENT RunPeriod: RUNPERIOD 1 1.9311704607E-002 1.8381894068E-002 Pass Pass 0.3614172139 2.1382900992 Pass Pass
13 M N1 APARTMENT RunPeriod: RUNPERIOD 1 1.8809865660E-002 1.4297801171E-002 Pass Pass 1.8956454683E-002 1.5579977608E-002 Pass Pass
14 M N2 APARTMENT RunPeriod: RUNPERIOD 1 1.8763219790E-002 1.4402707477E-002 Pass Pass 1.8969137960E-002 1.5570173233E-002 Pass Pass
15 M S1 APARTMENT RunPeriod: RUNPERIOD 1 7.6249396352E-003 1.5899183874E-002 Pass Pass 3.2588896721E-002 4.9319042945E-002 Pass Pass
16 M S2 APARTMENT RunPeriod: RUNPERIOD 1 7.6810252299E-003 1.6013417285E-002 Pass Pass 3.2503545796E-002 4.9422327066E-002 Pass Pass
17 T SW APARTMENT RunPeriod: RUNPERIOD 1 4.0388567330E-002 6.3402297437E-002 Pass Pass 2.1325541090 17.6625318416 Pass Pass
18 T NW APARTMENT RunPeriod: RUNPERIOD 1 2.8956910508E-002 4.2799474724E-002 Pass Pass 0.1098244350 0.3254975683 Pass Pass
19 T SE APARTMENT RunPeriod: RUNPERIOD 1 4.0356292479E-002 6.2133995544E-002 Pass Pass 0.1970191481 0.8118443516 Pass Pass
20 T NE APARTMENT RunPeriod: RUNPERIOD 1 1.2379696486E-002 1.9097373632E-002 Pass Pass 0.1470967804 0.5460567730 Pass Pass
21 T N1 APARTMENT RunPeriod: RUNPERIOD 1 1.5120406475E-002 2.0673826719E-002 Pass Pass 0.2516700158 1.3109640978 Pass Pass
22 T N2 APARTMENT RunPeriod: RUNPERIOD 1 1.4438136867E-002 1.9484493078E-002 Pass Pass 0.1790977067 0.7270958708 Pass Pass
23 T S1 APARTMENT RunPeriod: RUNPERIOD 1 4.0292360551E-002 5.7892462682E-002 Pass Pass 0.1540389590 0.5370483711 Pass Pass
24 T S2 APARTMENT RunPeriod: RUNPERIOD 1 4.0279816554E-002 5.8682126409E-002 Pass Pass 0.1375279039 0.3806118695 Pass Pass
25 T CORRIDOR RunPeriod: RUNPERIOD 1 4.0096387970E-002 1.9864508653E-002 Pass Pass 0.0000000000 0.0000000000 Pass Pass
26 G CORRIDOR RunPeriod: RUNPERIOD 1 0.1973009758 0.6178646847 Pass Pass 0.0000000000 0.0000000000 Pass Pass
27 M CORRIDOR RunPeriod: RUNPERIOD 1 1.1049867211E-002 4.5829074452E-003 Pass Pass 0.0000000000 0.0000000000 Pass Pass



Table of Contents

Report: Annual Heat Emissions Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Heat Emission by Components

Envelope Convection Zone Exfiltration Zone Exhaust Air HVAC Relief Air HVAC Reject Heat Total
Heat Emissions [GJ] 1370.56 41.25 0.00 5.81 1011.90 2429.53



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 0.50 0.00 0.50 Wetbulb [C] 2.10 140.00
TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 40.80 13.30 18.50 Wetbulb [C] 4.80 310.00


Monthly Precipitation Summary

Monthly Total Precipitation from .epw [mm] Monthly Total Hours of Rain from .epw Monthly Total Precipitation in Site:Precipitation [mm] Monthly Total Roof Irrigation Depth [mm] Monthly Total Rain Collection Volume [m3]
Jan 3.00 2      
Feb 34.00 28      
Mar 40.00 18      
Apr 0.00 0      
May 0.00 0      
Jun 0.00 0      
Jul 81.00 18      
Aug 71.00 20      
Sep 27.00 12      
Oct 9.00 6      
Nov 35.00 14      
Dec 0.00 0      


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Net Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL_GRD 0.30 0.644 0.712 35.30 28.24 180.00 90.00 S
G WWALL SWA RES_EXT_WALL_GRD 0.30 0.644 0.712 23.22 18.58 270.00 90.00 W
G GFLOOR SWA GGFLOORSWA_FFACTOR 1.00 0.274 0.287 88.25 88.25 90.00 180.00  
G NWALL NWA RES_EXT_WALL_GRD 0.30 0.644 0.712 35.30 28.24 0.00 90.00 N
G WWALL NWA RES_EXT_WALL_GRD 0.30 0.644 0.712 23.22 18.58 270.00 90.00 W
G GFLOOR NWA GGFLOORNWA_FFACTOR 1.00 0.274 0.287 88.25 88.25 90.00 180.00  
G SWALL SEA NONRES_EXT_WALL_GRD 0.30 0.757 0.854 35.30 28.24 180.00 90.00 S
G EWALL SEA NONRES_EXT_WALL_GRD 0.30 0.757 0.854 23.22 18.58 90.00 90.00 E
G GFLOOR SEA GGFLOORSEA_FFACTOR 1.00 0.274 0.287 88.25 88.25 90.00 180.00  
G NWALL NEA RES_EXT_WALL_GRD 0.30 0.644 0.712 35.30 28.24 0.00 90.00 N
G EWALL NEA RES_EXT_WALL_GRD 0.30 0.644 0.712 23.22 18.58 90.00 90.00 E
G GFLOOR NEA GGFLOORNEA_FFACTOR 1.00 0.274 0.287 88.25 88.25 90.00 180.00  
G NWALL N1A RES_EXT_WALL_GRD 0.30 0.644 0.712 35.30 28.24 0.00 90.00 N
G GFLOOR N1A GGFLOORN1A_FFACTOR 1.00 0.166 0.170 88.25 88.25 90.00 180.00  
G NWALL N2A RES_EXT_WALL_GRD 0.30 0.644 0.712 35.30 28.24 0.00 90.00 N
G GFLOOR N2A GGFLOORN2A_FFACTOR 1.00 0.166 0.170 88.25 88.25 90.00 180.00  
G SWALL S1A RES_EXT_WALL_GRD 0.30 0.644 0.712 35.30 28.24 180.00 90.00 S
G GFLOOR S1A GGFLOORS1A_FFACTOR 1.00 0.166 0.170 88.25 88.25 90.00 180.00  
G SWALL S2A RES_EXT_WALL_GRD 0.30 0.644 0.712 35.30 28.24 180.00 90.00 S
G GFLOOR S2A GGFLOORS2A_FFACTOR 1.00 0.166 0.170 88.25 88.25 90.00 180.00  
M WWALL SWA RES_EXT_WALL_MID 0.30 0.655 0.727 46.45 37.16 270.00 90.00 W
M SWALL SWA RES_EXT_WALL_MID 0.30 0.655 0.727 70.60 56.48 180.00 90.00 S
M NWALL NWA RES_EXT_WALL_MID 0.30 0.655 0.727 70.60 56.48 0.00 90.00 N
M WWALL NWA RES_EXT_WALL_MID 0.30 0.655 0.727 46.45 37.16 270.00 90.00 W
M EWALL SEA RES_EXT_WALL_MID 0.30 0.655 0.727 46.45 37.16 90.00 90.00 E
M SWALL SEA RES_EXT_WALL_MID 0.30 0.655 0.727 70.60 56.48 180.00 90.00 S
M NWALL NEA RES_EXT_WALL_MID 0.30 0.655 0.727 70.60 56.48 0.00 90.00 N
M EWALL NEA RES_EXT_WALL_MID 0.30 0.655 0.727 46.45 37.16 90.00 90.00 E
M NWALL N1A RES_EXT_WALL_MID 0.30 0.655 0.727 70.60 56.48 0.00 90.00 N
M NWALL N2A RES_EXT_WALL_MID 0.30 0.655 0.727 70.60 56.48 0.00 90.00 N
M SWALL S1A RES_EXT_WALL_MID 0.30 0.655 0.727 70.60 56.48 180.00 90.00 S
M SWALL S2A RES_EXT_WALL_MID 0.30 0.655 0.727 70.60 56.48 180.00 90.00 S
T WWALL SWA RES_EXT_WALL_TOP 0.30 0.837 0.957 23.22 18.58 270.00 90.00 W
T SWALL SWA RES_EXT_WALL_TOP 0.30 0.837 0.957 35.30 28.24 180.00 90.00 S
T ROOF SWA RES_ROOF 0.55 0.221 0.228 88.25 88.25 180.00 0.00  
T NWALL NWA RES_EXT_WALL_TOP 0.30 0.837 0.957 35.30 28.24 0.00 90.00 N
T WWALL NWA RES_EXT_WALL_TOP 0.30 0.837 0.957 23.22 18.58 270.00 90.00 W
T ROOF NWA RES_ROOF 0.55 0.221 0.228 88.25 88.25 180.00 0.00  
T EWALL SEA RES_EXT_WALL_TOP 0.30 0.837 0.957 23.22 18.58 90.00 90.00 E
T SWALL SEA RES_EXT_WALL_TOP 0.30 0.837 0.957 35.30 28.24 180.00 90.00 S
T ROOF SEA RES_ROOF 0.55 0.221 0.228 88.25 88.25 180.00 0.00  
T NWALL NEA RES_EXT_WALL_TOP 0.30 0.837 0.957 35.30 28.24 0.00 90.00 N
T EWALL NEA RES_EXT_WALL_TOP 0.30 0.837 0.957 23.22 18.58 90.00 90.00 E
T ROOF NEA RES_ROOF 0.55 0.221 0.228 88.25 88.25 180.00 0.00  
T NWALL N1A RES_EXT_WALL_TOP 0.30 0.837 0.957 35.30 28.24 0.00 90.00 N
T ROOF N1A RES_ROOF 0.55 0.221 0.228 88.25 88.25 180.00 0.00  
T NWALL N2A RES_EXT_WALL_TOP 0.30 0.837 0.957 35.30 28.24 0.00 90.00 N
T ROOF N2A RES_ROOF 0.55 0.221 0.228 88.25 88.25 180.00 0.00  
T SWALL S1A RES_EXT_WALL_TOP 0.30 0.837 0.957 35.30 28.24 180.00 90.00 S
T ROOF S1A RES_ROOF 0.55 0.221 0.228 88.25 88.25 180.00 0.00  
T SWALL S2A RES_EXT_WALL_TOP 0.30 0.837 0.957 35.30 28.24 180.00 90.00 S
T ROOF S2A RES_ROOF 0.55 0.221 0.228 88.25 88.25 180.00 0.00  
T WWALL C NONRES_EXT_WALL_TOP 0.30 0.951 1.109 5.11 5.11 270.00 90.00 W
T EWALL C NONRES_EXT_WALL_TOP 0.30 0.951 1.109 5.11 3.99 90.00 90.00 E
T ROOF C NONRES_ROOF 0.55 0.221 0.228 77.66 77.66 180.00 0.00  
G WWALL C NONRES_EXT_WALL_GRD 0.30 0.757 0.854 5.11 5.11 270.00 90.00 W
G EWALL C NONRES_EXT_WALL_GRD 0.30 0.757 0.854 5.11 1.79 90.00 90.00 E
G FLOOR C GFLOORC_FFACTOR 1.00 0.055 0.055 77.66 77.66 90.00 180.00  
M WWALL C NONRES_EXT_WALL_MID 0.30 0.769 0.869 10.22 10.22 270.00 90.00 W
M EWALL C NONRES_EXT_WALL_MID 0.30 0.769 0.869 10.22 7.99 90.00 90.00 E


Opaque Interior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Net Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G NIWALL SWA INT_WALL 0.30 2.511 6.299 35.30 35.30 0.00 90.00 N
G EIWALL SWA INT_WALL 0.30 2.511 6.299 23.22 23.22 90.00 90.00 E
G CEILIN SWA INT_SLAB_CEILING 0.30 2.104 3.839 88.25 88.25 180.00 0.00  
G SIWALL NWA INT_WALL 0.30 2.511 6.299 35.30 35.30 180.00 90.00 S
G EIWALL NWA INT_WALL 0.30 2.511 6.299 23.22 23.22 90.00 90.00 E
G CEILIN NWA INT_SLAB_CEILING 0.30 2.104 3.839 88.25 88.25 180.00 0.00  
G NIWALL SEA INT_WALL 0.30 2.511 6.299 35.30 35.30 0.00 90.00 N
iz-G EIWALL S2A INT_WALL 0.30 2.511 6.299 23.22 23.22 270.00 90.00 W
G CEILIN SEA INT_SLAB_CEILING 0.30 2.104 3.839 88.25 88.25 180.00 0.00  
G SIWALL NEA INT_WALL 0.30 2.511 6.299 35.30 35.30 180.00 90.00 S
iz-G EIWALL N2A INT_WALL 0.30 2.511 6.299 23.22 23.22 270.00 90.00 W
G CEILIN NEA INT_SLAB_CEILING 0.30 2.104 3.839 88.25 88.25 180.00 0.00  
G SIWALL N1A INT_WALL 0.30 2.511 6.299 35.30 35.30 180.00 90.00 S
G EIWALL N1A INT_WALL 0.30 2.511 6.299 23.22 23.22 90.00 90.00 E
iz-G EIWALL NWA INT_WALL 0.30 2.511 6.299 23.22 23.22 270.00 90.00 W
G CEILIN N1A INT_SLAB_CEILING 0.30 2.104 3.839 88.25 88.25 180.00 0.00  
G SIWALL N2A INT_WALL 0.30 2.511 6.299 35.30 35.30 180.00 90.00 S
G EIWALL N2A INT_WALL 0.30 2.511 6.299 23.22 23.22 90.00 90.00 E
iz-G EIWALL N1A INT_WALL 0.30 2.511 6.299 23.22 23.22 270.00 90.00 W
G CEILIN N2A INT_SLAB_CEILING 0.30 2.104 3.839 88.25 88.25 180.00 0.00  
G NIWALL S1A INT_WALL 0.30 2.511 6.299 35.30 35.30 0.00 90.00 N
G EIWALL S1A INT_WALL 0.30 2.511 6.299 23.22 23.22 90.00 90.00 E
iz-G EIWALL SWA INT_WALL 0.30 2.511 6.299 23.22 23.22 270.00 90.00 W
G CEILIN S1A INT_SLAB_CEILING 0.30 2.104 3.839 88.25 88.25 180.00 0.00  
G NIWALL S2A INT_WALL 0.30 2.511 6.299 35.30 35.30 0.00 90.00 N
G EIWALL S2A INT_WALL 0.30 2.511 6.299 23.22 23.22 90.00 90.00 E
iz-G EIWALL S1A INT_WALL 0.30 2.511 6.299 23.22 23.22 270.00 90.00 W
G CEILIN S2A INT_SLAB_CEILING 0.30 2.104 3.839 88.25 88.25 180.00 0.00  
M NIWALL SWA INT_WALL 0.30 2.511 6.299 70.60 70.60 0.00 90.00 N
M EIWALL SWA INT_WALL 0.30 2.511 6.299 46.45 46.45 90.00 90.00 E
M GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 176.50 176.50 90.00 180.00  
M CEILIN SWA INT_SLAB_CEILING 0.30 2.104 3.839 176.50 176.50 180.00 0.00  
M SIWALL NWA INT_WALL 0.30 2.511 6.299 70.60 70.60 180.00 90.00 S
M EIWALL NWA INT_WALL 0.30 2.511 6.299 46.45 46.45 90.00 90.00 E
M GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 176.50 176.50 90.00 180.00  
M CEILIN NWA INT_SLAB_CEILING 0.30 2.104 3.839 176.50 176.50 180.00 0.00  
M NIWALL SEA INT_WALL 0.30 2.511 6.299 70.60 70.60 0.00 90.00 N
iz-M EIWALL S2A INT_WALL 0.30 2.511 6.299 46.45 46.45 270.00 90.00 W
M GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 176.50 176.50 90.00 180.00  
M CEILIN SEA INT_SLAB_CEILING 0.30 2.104 3.839 176.50 176.50 180.00 0.00  
M SIWALL NEA INT_WALL 0.30 2.511 6.299 70.60 70.60 180.00 90.00 S
iz-M EIWALL N2A INT_WALL 0.30 2.511 6.299 46.45 46.45 270.00 90.00 W
M GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 176.50 176.50 90.00 180.00  
M CEILIN NEA INT_SLAB_CEILING 0.30 2.104 3.839 176.50 176.50 180.00 0.00  
M SIWALL N1A INT_WALL 0.30 2.511 6.299 70.60 70.60 180.00 90.00 S
M EIWALL N1A INT_WALL 0.30 2.511 6.299 46.45 46.45 90.00 90.00 E
iz-M EIWALL NWA INT_WALL 0.30 2.511 6.299 46.45 46.45 270.00 90.00 W
M GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 176.50 176.50 90.00 180.00  
M CEILIN N1A INT_SLAB_CEILING 0.30 2.104 3.839 176.50 176.50 180.00 0.00  
M SIWALL N2A INT_WALL 0.30 2.511 6.299 70.60 70.60 180.00 90.00 S
M EIWALL N2A INT_WALL 0.30 2.511 6.299 46.45 46.45 90.00 90.00 E
iz-M EIWALL N1A INT_WALL 0.30 2.511 6.299 46.45 46.45 270.00 90.00 W
M GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 176.50 176.50 90.00 180.00  
M CEILIN N2A INT_SLAB_CEILING 0.30 2.104 3.839 176.50 176.50 180.00 0.00  
M NIWALL S1A INT_WALL 0.30 2.511 6.299 70.60 70.60 0.00 90.00 N
M EIWALL S1A INT_WALL 0.30 2.511 6.299 46.45 46.45 90.00 90.00 E
iz-M EIWALL SWA INT_WALL 0.30 2.511 6.299 46.45 46.45 270.00 90.00 W
M GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 176.50 176.50 90.00 180.00  
M CEILIN S1A INT_SLAB_CEILING 0.30 2.104 3.839 176.50 176.50 180.00 0.00  
M NIWALL S2A INT_WALL 0.30 2.511 6.299 70.60 70.60 0.00 90.00 N
M EIWALL S2A INT_WALL 0.30 2.511 6.299 46.45 46.45 90.00 90.00 E
iz-M EIWALL S1A INT_WALL 0.30 2.511 6.299 46.45 46.45 270.00 90.00 W
M GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 176.50 176.50 90.00 180.00  
M CEILIN S2A INT_SLAB_CEILING 0.30 2.104 3.839 176.50 176.50 180.00 0.00  
T NIWALL SWA INT_WALL 0.30 2.511 6.299 35.30 35.30 0.00 90.00 N
T EIWALL SWA INT_WALL 0.30 2.511 6.299 23.22 23.22 90.00 90.00 E
T GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 88.25 88.25 90.00 180.00  
T SIWALL NWA INT_WALL 0.30 2.511 6.299 35.30 35.30 180.00 90.00 S
T EIWALL NWA INT_WALL 0.30 2.511 6.299 23.22 23.22 90.00 90.00 E
T GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 88.25 88.25 90.00 180.00  
T NIWALL SEA INT_WALL 0.30 2.511 6.299 35.30 35.30 0.00 90.00 N
iz-T EIWALL S2A INT_WALL 0.30 2.511 6.299 23.22 23.22 270.00 90.00 W
T GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 88.25 88.25 90.00 180.00  
T SIWALL NEA INT_WALL 0.30 2.511 6.299 35.30 35.30 180.00 90.00 S
iz-T EIWALL N2A INT_WALL 0.30 2.511 6.299 23.22 23.22 270.00 90.00 W
T GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 88.25 88.25 90.00 180.00  
T SIWALL N1A INT_WALL 0.30 2.511 6.299 35.30 35.30 180.00 90.00 S
T EIWALL N1A INT_WALL 0.30 2.511 6.299 23.22 23.22 90.00 90.00 E
iz-T EIWALL NWA INT_WALL 0.30 2.511 6.299 23.22 23.22 270.00 90.00 W
T GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 88.25 88.25 90.00 180.00  
T SIWALL N2A INT_WALL 0.30 2.511 6.299 35.30 35.30 180.00 90.00 S
T EIWALL N2A INT_WALL 0.30 2.511 6.299 23.22 23.22 90.00 90.00 E
iz-T EIWALL N1A INT_WALL 0.30 2.511 6.299 23.22 23.22 270.00 90.00 W
T GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 88.25 88.25 90.00 180.00  
T NIWALL S1A INT_WALL 0.30 2.511 6.299 35.30 35.30 0.00 90.00 N
T EIWALL S1A INT_WALL 0.30 2.511 6.299 23.22 23.22 90.00 90.00 E
iz-T EIWALL SWA INT_WALL 0.30 2.511 6.299 23.22 23.22 270.00 90.00 W
T GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 88.25 88.25 90.00 180.00  
T NIWALL S2A INT_WALL 0.30 2.511 6.299 35.30 35.30 0.00 90.00 N
T EIWALL S2A INT_WALL 0.30 2.511 6.299 23.22 23.22 90.00 90.00 E
iz-T EIWALL S1A INT_WALL 0.30 2.511 6.299 23.22 23.22 270.00 90.00 W
T GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 88.25 88.25 90.00 180.00  
iz-T NIWALL SWA INT_WALL 0.30 2.511 6.299 35.30 35.30 180.00 90.00 S
iz-T NIWALL S1A INT_WALL 0.30 2.511 6.299 35.30 35.30 180.00 90.00 S
iz-T NIWALL S2A INT_WALL 0.30 2.511 6.299 35.30 35.30 180.00 90.00 S
iz-T NIWALL SEA INT_WALL 0.30 2.511 6.299 35.30 35.30 180.00 90.00 S
iz-T SIWALL NWA INT_WALL 0.30 2.511 6.299 35.30 35.30 0.00 90.00 N
iz-T SIWALL N1A INT_WALL 0.30 2.511 6.299 35.30 35.30 0.00 90.00 N
iz-T SIWALL N2A INT_WALL 0.30 2.511 6.299 35.30 35.30 0.00 90.00 N
iz-T SIWALL NEA INT_WALL 0.30 2.511 6.299 35.30 35.30 0.00 90.00 N
T FLOOR C EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 77.66 77.66 90.00 180.00  
iz-G NIWALL SWA INT_WALL 0.30 2.511 6.299 35.30 35.30 180.00 90.00 S
iz-G NIWALL S1A INT_WALL 0.30 2.511 6.299 35.30 35.30 180.00 90.00 S
iz-G NIWALL S2A INT_WALL 0.30 2.511 6.299 35.30 35.30 180.00 90.00 S
iz-G NIWALL SEA INT_WALL 0.30 2.511 6.299 35.30 35.30 180.00 90.00 S
iz-G SIWALL NWA INT_WALL 0.30 2.511 6.299 35.30 35.30 0.00 90.00 N
iz-G SIWALL N1A INT_WALL 0.30 2.511 6.299 35.30 35.30 0.00 90.00 N
iz-G SIWALL N2A INT_WALL 0.30 2.511 6.299 35.30 35.30 0.00 90.00 N
iz-G SIWALL NEA INT_WALL 0.30 2.511 6.299 35.30 35.30 0.00 90.00 N
G CEILING C INT_SLAB_CEILING 0.30 2.104 3.839 77.66 77.66 180.00 0.00  
iz-M NIWALL SWA INT_WALL 0.30 2.511 6.299 70.60 70.60 180.00 90.00 S
iz-M NIWALL S1A INT_WALL 0.30 2.511 6.299 70.60 70.60 180.00 90.00 S
iz-M NIWALL S2A INT_WALL 0.30 2.511 6.299 70.60 70.60 180.00 90.00 S
iz-M NIWALL SEA INT_WALL 0.30 2.511 6.299 70.60 70.60 180.00 90.00 S
iz-M SIWALL NWA INT_WALL 0.30 2.511 6.299 70.60 70.60 0.00 90.00 N
iz-M SIWALL N1A INT_WALL 0.30 2.511 6.299 70.60 70.60 0.00 90.00 N
iz-M SIWALL N2A INT_WALL 0.30 2.511 6.299 70.60 70.60 0.00 90.00 N
iz-M SIWALL NEA INT_WALL 0.30 2.511 6.299 70.60 70.60 0.00 90.00 N
M FLOOR C EXT_SLAB_8IN_WITH_CARPET 0.30 1.591 3.285 155.32 155.32 90.00 180.00  
M CEILING C INT_SLAB_CEILING 0.30 2.104 3.839 155.32 155.32 180.00 0.00  
G INTERNALMASS SWA INTERIORFURNISHINGS 0.30   0.800 88.25   0.00 90.00 N
G INTERNALMASS NWA INTERIORFURNISHINGS 0.30   0.800 88.25   0.00 90.00 N
G INTERNALMASS SEA INTERIORFURNISHINGS 0.30   0.800 88.25   0.00 90.00 N
G INTERNALMASS NEA INTERIORFURNISHINGS 0.30   0.800 88.25   0.00 90.00 N
G INTERNALMASS N1A INTERIORFURNISHINGS 0.30   0.800 88.25   0.00 90.00 N
G INTERNALMASS N2A INTERIORFURNISHINGS 0.30   0.800 88.25   0.00 90.00 N
G INTERNALMASS S1A INTERIORFURNISHINGS 0.30   0.800 88.25   0.00 90.00 N
G INTERNALMASS S2A INTERIORFURNISHINGS 0.30   0.800 88.25   0.00 90.00 N
M INTERNALMASS SWA INTERIORFURNISHINGS 0.30   0.800 353.00   0.00 90.00 N
M INTERNALMASS NWA INTERIORFURNISHINGS 0.30   0.800 353.00   0.00 90.00 N
M INTERNALMASS SEA INTERIORFURNISHINGS 0.30   0.800 353.00   0.00 90.00 N
M INTERNALMASS NEA INTERIORFURNISHINGS 0.30   0.800 353.00   0.00 90.00 N
M INTERNALMASS N1A INTERIORFURNISHINGS 0.30   0.800 353.00   0.00 90.00 N
M INTERNALMASS N2A INTERIORFURNISHINGS 0.30   0.800 353.00   0.00 90.00 N
M INTERNALMASS S1A INTERIORFURNISHINGS 0.30   0.800 353.00   0.00 90.00 N
M INTERNALMASS S2A INTERIORFURNISHINGS 0.30   0.800 353.00   0.00 90.00 N
T INTERNALMASS SWA INTERIORFURNISHINGS 0.30   0.800 88.25   0.00 90.00 N
T INTERNALMASS NWA INTERIORFURNISHINGS 0.30   0.800 88.25   0.00 90.00 N
T INTERNALMASS SEA INTERIORFURNISHINGS 0.30   0.800 88.25   0.00 90.00 N
T INTERNALMASS NEA INTERIORFURNISHINGS 0.30   0.800 88.25   0.00 90.00 N
T INTERNALMASS N1A INTERIORFURNISHINGS 0.30   0.800 88.25   0.00 90.00 N
T INTERNALMASS N2A INTERIORFURNISHINGS 0.30   0.800 88.25   0.00 90.00 N
T INTERNALMASS S1A INTERIORFURNISHINGS 0.30   0.800 88.25   0.00 90.00 N
T INTERNALMASS S2A INTERIORFURNISHINGS 0.30   0.800 88.25   0.00 90.00 N


Exterior Fenestration

Construction Frame and Divider Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] NFRC Product Type Assembly U-Factor [W/m2-K] Assembly SHGC Assembly Visible Transmittance Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW1 S SWA RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 7.06 2.769 0.246 0.270             No G SWALL SWA 180.00 90.00 S
GWINDOW1 W SWA RESWINDOW_U_0.487_SHGC_0.245   4.65 0.00 0.00 4.65 4.65 2.769 0.246 0.270             No G WWALL SWA 270.00 90.00 W
GWINDOW1 N NWA RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 7.06 2.769 0.246 0.270             No G NWALL NWA 0.00 90.00 N
GWINDOW1 W NWA RESWINDOW_U_0.487_SHGC_0.245   4.65 0.00 0.00 4.65 4.65 2.769 0.246 0.270             No G WWALL NWA 270.00 90.00 W
GWINDOW1 S SEA NONRESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 7.06 2.769 0.246 0.270             No G SWALL SEA 180.00 90.00 S
GWINDOW1 E SEA NONRESWINDOW_U_0.487_SHGC_0.245   4.65 0.00 0.00 4.65 4.65 2.769 0.246 0.270             No G EWALL SEA 90.00 90.00 E
GWINDOW1 N NEA RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 7.06 2.769 0.246 0.270             No G NWALL NEA 0.00 90.00 N
GWINDOW1 E NEA RESWINDOW_U_0.487_SHGC_0.245   4.65 0.00 0.00 4.65 4.65 2.769 0.246 0.270             No G EWALL NEA 90.00 90.00 E
GWINDOW1 N N1A RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 7.06 2.769 0.246 0.270             No G NWALL N1A 0.00 90.00 N
GWINDOW1 N N2A RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 7.06 2.769 0.246 0.270             No G NWALL N2A 0.00 90.00 N
GWINDOW1 S S1A RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 7.06 2.769 0.246 0.270             No G SWALL S1A 180.00 90.00 S
GWINDOW1 S S2A RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 7.06 2.769 0.246 0.270             No G SWALL S2A 180.00 90.00 S
MWINDOW1 W SWA RESWINDOW_U_0.487_SHGC_0.245   4.65 0.00 0.00 4.65 9.29 2.769 0.246 0.270             No M WWALL SWA 270.00 90.00 W
MWINDOW1 S SWA RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 14.12 2.769 0.246 0.270             No M SWALL SWA 180.00 90.00 S
MWINDOW1 N NWA RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 14.12 2.769 0.246 0.270             No M NWALL NWA 0.00 90.00 N
MWINDOW1 W NWA RESWINDOW_U_0.487_SHGC_0.245   4.65 0.00 0.00 4.65 9.29 2.769 0.246 0.270             No M WWALL NWA 270.00 90.00 W
MWINDOW1 E SEA RESWINDOW_U_0.487_SHGC_0.245   4.65 0.00 0.00 4.65 9.29 2.769 0.246 0.270             No M EWALL SEA 90.00 90.00 E
MWINDOW1 S SEA RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 14.12 2.769 0.246 0.270             No M SWALL SEA 180.00 90.00 S
MWINDOW1 N NEA RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 14.12 2.769 0.246 0.270             No M NWALL NEA 0.00 90.00 N
MWINDOW1 E NEA RESWINDOW_U_0.487_SHGC_0.245   4.65 0.00 0.00 4.65 9.29 2.769 0.246 0.270             No M EWALL NEA 90.00 90.00 E
MWINDOW1 N N1A RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 14.12 2.769 0.246 0.270             No M NWALL N1A 0.00 90.00 N
MWINDOW1 N N2A RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 14.12 2.769 0.246 0.270             No M NWALL N2A 0.00 90.00 N
MWINDOW1 S S1A RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 14.12 2.769 0.246 0.270             No M SWALL S1A 180.00 90.00 S
MWINDOW1 S S2A RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 14.12 2.769 0.246 0.270             No M SWALL S2A 180.00 90.00 S
TWINDOW1 W SWA RESWINDOW_U_0.487_SHGC_0.245   4.65 0.00 0.00 4.65 4.65 2.769 0.246 0.270             No T WWALL SWA 270.00 90.00 W
TWINDOW1 S SWA RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 7.06 2.769 0.246 0.270             No T SWALL SWA 180.00 90.00 S
TWINDOW1 N NWA RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 7.06 2.769 0.246 0.270             No T NWALL NWA 0.00 90.00 N
TWINDOW1 W NWA RESWINDOW_U_0.487_SHGC_0.245   4.65 0.00 0.00 4.65 4.65 2.769 0.246 0.270             No T WWALL NWA 270.00 90.00 W
TWINDOW1 E SEA RESWINDOW_U_0.487_SHGC_0.245   4.65 0.00 0.00 4.65 4.65 2.769 0.246 0.270             No T EWALL SEA 90.00 90.00 E
TWINDOW1 S SEA RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 7.06 2.769 0.246 0.270             No T SWALL SEA 180.00 90.00 S
TWINDOW1 N NEA RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 7.06 2.769 0.246 0.270             No T NWALL NEA 0.00 90.00 N
TWINDOW1 E NEA RESWINDOW_U_0.487_SHGC_0.245   4.65 0.00 0.00 4.65 4.65 2.769 0.246 0.270             No T EWALL NEA 90.00 90.00 E
TWINDOW1 N N1A RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 7.06 2.769 0.246 0.270             No T NWALL N1A 0.00 90.00 N
TWINDOW1 N N2A RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 7.06 2.769 0.246 0.270             No T NWALL N2A 0.00 90.00 N
TWINDOW1 S S1A RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 7.06 2.769 0.246 0.270             No T SWALL S1A 180.00 90.00 S
TWINDOW1 S S2A RESWINDOW_U_0.487_SHGC_0.245   7.06 0.00 0.00 7.06 7.06 2.769 0.246 0.270             No T SWALL S2A 180.00 90.00 S
TWINDOW14 NONRESWINDOW_U_0.487_SHGC_0.245   1.11 0.00 0.00 1.11 1.11 2.769 0.246 0.270             No T EWALL C 90.00 90.00 E
ENTRANCE DOOR NONRESWINDOW_U_0.487_SHGC_0.245   3.32 0.00 0.00 3.32 3.32 2.769 0.246 0.270             No G EWALL C 90.00 90.00 E
MWINDOW14 NONRESWINDOW_U_0.487_SHGC_0.245   1.11 0.00 0.00 1.11 2.23 2.769 0.246 0.270             No M EWALL C 90.00 90.00 E
Total or Average             306.92 2.769 0.246 0.270                      
North Total or Average             112.97 2.769 0.246 0.270                      
Non-North Total or Average             193.95 2.769 0.246 0.270                      


Exterior Fenestration Shaded State

Frame and Divider Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance NFRC Product Type Assembly U-Factor [W/m2-K] Assembly SHGC Assembly Visible Transmittance
None                


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance
Total or Average     0.00 - - -


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          


Interior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW1 S SWA 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 N NWA 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 S SEA 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW1 N NEA 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW1 N N1A 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 N N2A 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 S S1A 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 S S2A 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW1 S SWA 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NWA 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 S SEA 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NEA 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 N N1A 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 N N2A 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 S S1A 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 S S2A 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW1 S SWA 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NWA 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 S SEA 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NEA 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 N N1A 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 N N2A 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 S S1A 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 S S2A 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Interior Lighting

Zone Name Space Name Space Type Lighting Power Density [W/m2] Space Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
LIGHTING_HARDWIRED_GSW G SW APARTMENT G SW APARTMENT GENERAL 2.1528 88.25 189.98 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.32
LIGHTING_HARDWIRED_GNW G NW APARTMENT G NW APARTMENT GENERAL 2.1528 88.25 189.98 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.32
LIGHTING_HARDWIRED_OFFICE OFFICE OFFICE GENERAL 6.8737 88.25 606.60 LightsWired LTG_SCH_OFFICE 42.74 168.00 41.89 0.0000 Y 4.77
LIGHTING_HARDWIRED_GNE G NE APARTMENT G NE APARTMENT GENERAL 2.1528 88.25 189.98 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.32
LIGHTING_HARDWIRED_GN1 G N1 APARTMENT G N1 APARTMENT GENERAL 2.1528 88.25 189.98 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.32
LIGHTING_HARDWIRED_GN2 G N2 APARTMENT G N2 APARTMENT GENERAL 2.1528 88.25 189.98 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.32
LIGHTING_HARDWIRED_GS1 G S1 APARTMENT G S1 APARTMENT GENERAL 2.1528 88.25 189.98 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.32
LIGHTING_HARDWIRED_GS2 G S2 APARTMENT G S2 APARTMENT GENERAL 2.1528 88.25 189.98 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.32
LIGHTING_HARDWIRED_MSW M SW APARTMENT M SW APARTMENT GENERAL 2.1528 176.50 379.96 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.65
LIGHTING_HARDWIRED_MNW M NW APARTMENT M NW APARTMENT GENERAL 2.1528 176.50 379.96 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.65
LIGHTING_HARDWIRED_MSE M SE APARTMENT M SE APARTMENT GENERAL 2.1528 176.50 379.96 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.65
LIGHTING_HARDWIRED_MNE M NE APARTMENT M NE APARTMENT GENERAL 2.1528 176.50 379.96 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.65
LIGHTING_HARDWIRED_MN1 M N1 APARTMENT M N1 APARTMENT GENERAL 2.1528 176.50 379.96 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.65
LIGHTING_HARDWIRED_MN2 M N2 APARTMENT M N2 APARTMENT GENERAL 2.1528 176.50 379.96 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.65
LIGHTING_HARDWIRED_MS1 M S1 APARTMENT M S1 APARTMENT GENERAL 2.1528 176.50 379.96 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.65
LIGHTING_HARDWIRED_MS2 M S2 APARTMENT M S2 APARTMENT GENERAL 2.1528 176.50 379.96 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.65
LIGHTING_HARDWIRED_TSW T SW APARTMENT T SW APARTMENT GENERAL 2.1528 88.25 189.98 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.32
LIGHTING_HARDWIRED_TNW T NW APARTMENT T NW APARTMENT GENERAL 2.1528 88.25 189.98 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.32
LIGHTING_HARDWIRED_TSE T SE APARTMENT T SE APARTMENT GENERAL 2.1528 88.25 189.98 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.32
LIGHTING_HARDWIRED_TNE T NE APARTMENT T NE APARTMENT GENERAL 2.1528 88.25 189.98 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.32
LIGHTING_HARDWIRED_TN1 T N1 APARTMENT T N1 APARTMENT GENERAL 2.1528 88.25 189.98 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.32
LIGHTING_HARDWIRED_TN2 T N2 APARTMENT T N2 APARTMENT GENERAL 2.1528 88.25 189.98 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.32
LIGHTING_HARDWIRED_TS1 T S1 APARTMENT T S1 APARTMENT GENERAL 2.1528 88.25 189.98 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.32
LIGHTING_HARDWIRED_TS2 T S2 APARTMENT T S2 APARTMENT GENERAL 2.1528 88.25 189.98 LightsWired LTG_SCH_APARTMENT_HARDWIRED 9.09 168.00 9.09 0.0000 Y 0.32
LIGHTING_HARDWIRED_GC G CORRIDOR G CORRIDOR GENERAL 5.1587 77.66 400.62 LightsWired LTG_SCH_CORRIDOR 114.76 168.00 114.76 0.0000 N 8.63
LIGHTING_HARDWIRED_MC M CORRIDOR M CORRIDOR GENERAL 5.1587 155.32 801.25 LightsWired LTG_SCH_CORRIDOR 114.76 168.00 114.76 0.0000 N 17.26
LIGHTING_HARDWIRED_TC T CORRIDOR T CORRIDOR GENERAL 5.1587 77.66 400.62 LightsWired LTG_SCH_CORRIDOR 114.76 168.00 114.76 0.0000 N 8.63
LIGHTING_PLUGIN_GSW G SW APARTMENT G SW APARTMENT GENERAL 0.9688 88.25 85.49 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.15
LIGHTING_PLUGIN_GNW G NW APARTMENT G NW APARTMENT GENERAL 0.9688 88.25 85.49 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.15
LIGHTING_PLUGIN_GNE G NE APARTMENT G NE APARTMENT GENERAL 0.9688 88.25 85.49 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.15
LIGHTING_PLUGIN_GN1 G N1 APARTMENT G N1 APARTMENT GENERAL 0.9688 88.25 85.49 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.15
LIGHTING_PLUGIN_GN2 G N2 APARTMENT G N2 APARTMENT GENERAL 0.9688 88.25 85.49 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.15
LIGHTING_PLUGIN_GS1 G S1 APARTMENT G S1 APARTMENT GENERAL 0.9688 88.25 85.49 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.15
LIGHTING_PLUGIN_GS2 G S2 APARTMENT G S2 APARTMENT GENERAL 0.9688 88.25 85.49 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.15
LIGHTING_PLUGIN_MSW M SW APARTMENT M SW APARTMENT GENERAL 0.9688 176.50 170.98 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.29
LIGHTING_PLUGIN_MNW M NW APARTMENT M NW APARTMENT GENERAL 0.9688 176.50 170.98 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.29
LIGHTING_PLUGIN_MSE M SE APARTMENT M SE APARTMENT GENERAL 0.9688 176.50 170.98 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.29
LIGHTING_PLUGIN_MNE M NE APARTMENT M NE APARTMENT GENERAL 0.9688 176.50 170.98 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.29
LIGHTING_PLUGIN_MN1 M N1 APARTMENT M N1 APARTMENT GENERAL 0.9688 176.50 170.98 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.29
LIGHTING_PLUGIN_MN2 M N2 APARTMENT M N2 APARTMENT GENERAL 0.9688 176.50 170.98 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.29
LIGHTING_PLUGIN_MS1 M S1 APARTMENT M S1 APARTMENT GENERAL 0.9688 176.50 170.98 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.29
LIGHTING_PLUGIN_MS2 M S2 APARTMENT M S2 APARTMENT GENERAL 0.9688 176.50 170.98 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.29
LIGHTING_PLUGIN_TSW T SW APARTMENT T SW APARTMENT GENERAL 0.9688 88.25 85.49 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.15
LIGHTING_PLUGIN_TNW T NW APARTMENT T NW APARTMENT GENERAL 0.9688 88.25 85.49 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.15
LIGHTING_PLUGIN_TSE T SE APARTMENT T SE APARTMENT GENERAL 0.9688 88.25 85.49 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.15
LIGHTING_PLUGIN_TNE T NE APARTMENT T NE APARTMENT GENERAL 0.9688 88.25 85.49 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.15
LIGHTING_PLUGIN_TN1 T N1 APARTMENT T N1 APARTMENT GENERAL 0.9688 88.25 85.49 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.15
LIGHTING_PLUGIN_TN2 T N2 APARTMENT T N2 APARTMENT GENERAL 0.9688 88.25 85.49 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.15
LIGHTING_PLUGIN_TS1 T S1 APARTMENT T S1 APARTMENT GENERAL 0.9688 88.25 85.49 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.15
LIGHTING_PLUGIN_TS2 T S2 APARTMENT T S2 APARTMENT GENERAL 0.9688 88.25 85.49 LightsPlugIn LTG_SCH_APARTMENT_PLUGIN 9.09 168.00 9.09 0.0000 Y 0.15
Interior Lighting Total       1.8310 5870.34 10748.75               41.47


Daylighting

Zone Control Name Daylighting Method Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None              


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 1451.66 AstronomicalClock -   83.79 83.79 22.83
Exterior Lighting Total 1451.66           22.83



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Central Plant

Type Reference Capacity [W] Reference Efficiency [W/W] Rated Capacity [W] Rated Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
None              


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
SPLIT GSW HP COOLING COIL Coil:Cooling:DX:SingleSpeed   5660.35 4531.99 1128.36 0.80 4.02    
SPLIT GNW HP COOLING COIL Coil:Cooling:DX:SingleSpeed   5565.77 4456.26 1109.51 0.80 4.02    
SPLIT OFFICE HP COOLING COIL Coil:Cooling:DX:SingleSpeed   6771.16 5421.36 1349.79 0.80 4.02    
SPLIT GNE HP COOLING COIL Coil:Cooling:DX:SingleSpeed   5171.10 4140.26 1030.83 0.80 4.02    
SPLIT GN1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   4434.00 3550.11 883.90 0.80 4.02    
SPLIT GN2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   4427.01 3544.51 882.50 0.80 4.02    
SPLIT GS1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   4521.76 3620.37 901.39 0.80 4.02    
SPLIT GS2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   4617.61 3697.11 920.50 0.80 4.02    
SPLIT MSW HP COOLING COIL Coil:Cooling:DX:SingleSpeed   12886.90 10317.96 2568.94 0.80 4.02    
SPLIT MNW HP COOLING COIL Coil:Cooling:DX:SingleSpeed   12709.01 10175.54 2533.47 0.80 4.02    
SPLIT MSE HP COOLING COIL Coil:Cooling:DX:SingleSpeed   11834.39 9475.27 2359.12 0.80 4.02    
SPLIT MNE HP COOLING COIL Coil:Cooling:DX:SingleSpeed   11658.90 9334.76 2324.14 0.80 4.02    
SPLIT MN1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   9996.40 8003.67 1992.73 0.80 4.02    
SPLIT MN2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   9978.73 7989.52 1989.21 0.80 4.02    
SPLIT MS1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   10166.68 8140.01 2026.67 0.80 4.02    
SPLIT MS2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   10150.76 8127.26 2023.50 0.80 4.02    
SPLIT TSW HP COOLING COIL Coil:Cooling:DX:SingleSpeed   7447.88 5963.18 1484.70 0.80 4.02    
SPLIT TNW HP COOLING COIL Coil:Cooling:DX:SingleSpeed   7430.92 5949.61 1481.32 0.80 4.02    
SPLIT TSE HP COOLING COIL Coil:Cooling:DX:SingleSpeed   6673.20 5342.94 1330.27 0.80 4.02    
SPLIT TNE HP COOLING COIL Coil:Cooling:DX:SingleSpeed   6655.23 5328.54 1326.68 0.80 4.02    
SPLIT TN1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   5977.34 4785.79 1191.55 0.80 4.02    
SPLIT TN2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   5953.31 4766.55 1186.76 0.80 4.02    
SPLIT TS1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   6006.98 4809.52 1197.46 0.80 4.02    
SPLIT TS2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   5983.02 4790.34 1192.68 0.80 4.02    
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.

DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER User [Btu/W-h] SEER Standard [Btu/W-h] IEER [Btu/W-h]
SPLIT GSW HP COOLING COIL   5392.4 3.20 10.91 11.33 10.72 10.58
SPLIT GNW HP COOLING COIL   5302.3 3.20 10.91 11.33 10.72 10.58
SPLIT OFFICE HP COOLING COIL   6450.6 3.20 10.91 11.33 10.72 10.58
SPLIT GNE HP COOLING COIL   4926.3 3.20 10.91 11.33 10.72 10.58
SPLIT GN1 HP COOLING COIL   4224.1 3.20 10.91 11.33 10.72 10.58
SPLIT GN2 HP COOLING COIL   4217.4 3.20 10.91 11.33 10.72 10.58
SPLIT GS1 HP COOLING COIL   4307.7 3.20 10.91 11.33 10.72 10.58
SPLIT GS2 HP COOLING COIL   4399.0 3.20 10.91 11.33 10.72 10.58
SPLIT MSW HP COOLING COIL   12276.8 3.20 10.91 11.33 10.72 10.58
SPLIT MNW HP COOLING COIL   12107.3 3.20 10.91 11.33 10.72 10.58
SPLIT MSE HP COOLING COIL   11274.1 3.20 10.91 11.33 10.72 10.58
SPLIT MNE HP COOLING COIL   11106.9 3.20 10.91 11.33 10.72 10.58
SPLIT MN1 HP COOLING COIL   9523.1 3.20 10.91 11.33 10.72 10.58
SPLIT MN2 HP COOLING COIL   9506.3 3.20 10.91 11.33 10.72 10.58
SPLIT MS1 HP COOLING COIL   9685.4 3.20 10.91 11.33 10.72 10.58
SPLIT MS2 HP COOLING COIL   9670.2 3.20 10.91 11.33 10.72 10.58
SPLIT TSW HP COOLING COIL   7095.3 3.20 10.91 11.33 10.72 10.58
SPLIT TNW HP COOLING COIL   7079.1 3.20 10.91 11.33 10.72 10.58
SPLIT TSE HP COOLING COIL   6357.3 3.20 10.91 11.33 10.72 10.58
SPLIT TNE HP COOLING COIL   6340.2 3.20 10.91 11.33 10.72 10.58
SPLIT TN1 HP COOLING COIL   5694.4 3.20 10.91 11.33 10.72 10.58
SPLIT TN2 HP COOLING COIL   5671.5 3.20 10.91 11.33 10.72 10.58
SPLIT TS1 HP COOLING COIL   5722.6 3.20 10.91 11.33 10.72 10.58
SPLIT TS2 HP COOLING COIL   5699.8 3.20 10.91 11.33 10.72 10.58
ANSI/AHRI ratings account for supply air fan heat and electric power. SEER User is calculated using user-input PLF curve and cooling coefficient of degradation whereas SEER Standard is calculated using AHRI Std 210/240-2008 default PLF curve and cooling coefficient of degradation.

DX Cooling Coil ASHRAE 127 Standard Ratings Report

DX Cooling Coil Type Rated Net Cooling Capacity Test A [W] Rated Electric Power Test A [W] Rated Net Cooling Capacity Test B [W] Rated Electric Power Test B [W] Rated Net Cooling Capacity Test C [W] Rated Electric Power Test C [W] Rated Net Cooling Capacity Test D [W] Rated Electric Power Test D [W]
SPLIT GSW HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT GNW HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT OFFICE HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT GNE HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT GN1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT GN2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT GS1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT GS2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT MSW HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT MNW HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT MSE HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT MNE HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT MN1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT MN2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT MS1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT MS2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT TSW HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT TNW HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT TSE HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT TNE HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT TN1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT TN2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT TS1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
SPLIT TS2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
SPLIT GSW HEATING COIL Coil:Heating:DX:SingleSpeed 5931.6 3303.6 8.06 4
SPLIT GNW HEATING COIL Coil:Heating:DX:SingleSpeed 5832.5 3248.4 8.05 4
SPLIT OFFICE HEATING COIL Coil:Heating:DX:SingleSpeed 7095.7 3951.9 8.04 4
SPLIT GNE HEATING COIL Coil:Heating:DX:SingleSpeed 5418.9 3018.0 8.02 4
SPLIT GN1 HEATING COIL Coil:Heating:DX:SingleSpeed 4646.5 2587.8 8.08 4
SPLIT GN2 HEATING COIL Coil:Heating:DX:SingleSpeed 4639.2 2583.7 8.08 4
SPLIT GS1 HEATING COIL Coil:Heating:DX:SingleSpeed 4738.5 2639.1 8.09 4
SPLIT GS2 HEATING COIL Coil:Heating:DX:SingleSpeed 4838.9 2695.0 8.10 4
SPLIT MSW HEATING COIL Coil:Heating:DX:SingleSpeed 13504.5 7521.2 8.02 4
SPLIT MNW HEATING COIL Coil:Heating:DX:SingleSpeed 13318.1 7417.4 8.02 4
SPLIT MSE HEATING COIL Coil:Heating:DX:SingleSpeed 12401.6 6906.9 8.08 4
SPLIT MNE HEATING COIL Coil:Heating:DX:SingleSpeed 12217.7 6804.5 8.07 4
SPLIT MN1 HEATING COIL Coil:Heating:DX:SingleSpeed 10475.5 5834.2 8.06 4
SPLIT MN2 HEATING COIL Coil:Heating:DX:SingleSpeed 10457.0 5823.9 8.06 4
SPLIT MS1 HEATING COIL Coil:Heating:DX:SingleSpeed 10653.9 5933.6 8.07 4
SPLIT MS2 HEATING COIL Coil:Heating:DX:SingleSpeed 10637.3 5924.3 8.07 4
SPLIT TSW HEATING COIL Coil:Heating:DX:SingleSpeed 7804.8 4346.8 8.08 4
SPLIT TNW HEATING COIL Coil:Heating:DX:SingleSpeed 7787.1 4336.9 8.08 4
SPLIT TSE HEATING COIL Coil:Heating:DX:SingleSpeed 6993.0 3894.7 8.03 4
SPLIT TNE HEATING COIL Coil:Heating:DX:SingleSpeed 6974.2 3884.2 8.03 4
SPLIT TN1 HEATING COIL Coil:Heating:DX:SingleSpeed 6263.8 3488.6 8.08 4
SPLIT TN2 HEATING COIL Coil:Heating:DX:SingleSpeed 6238.6 3474.5 8.08 4
SPLIT TS1 HEATING COIL Coil:Heating:DX:SingleSpeed 6294.9 3505.9 8.09 4
SPLIT TS2 HEATING COIL Coil:Heating:DX:SingleSpeed 6269.8 3491.9 8.08 4
ANSI/AHRI ratings account for supply air fan heat and electric power.

Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
SPLIT GSW HEATING COIL Coil:Heating:DX:SingleSpeed   5660.35 3.81
SPLIT GSW_SUPPHEATCOIL Coil:Heating:Electric   5660.35 1.00
SPLIT GNW HEATING COIL Coil:Heating:DX:SingleSpeed   5565.77 3.81
SPLIT GNW_SUPPHEATCOIL Coil:Heating:Electric   5565.77 1.00
SPLIT OFFICE HEATING COIL Coil:Heating:DX:SingleSpeed   6771.16 3.81
SPLIT OFFICE_SUPPHEATCOIL Coil:Heating:Electric   6771.16 1.00
SPLIT GNE HEATING COIL Coil:Heating:DX:SingleSpeed   5171.10 3.81
SPLIT GNE_SUPPHEATCOIL Coil:Heating:Electric   5171.10 1.00
SPLIT GN1 HEATING COIL Coil:Heating:DX:SingleSpeed   4434.00 3.81
SPLIT GN1_SUPPHEATCOIL Coil:Heating:Electric   4434.00 1.00
SPLIT GN2 HEATING COIL Coil:Heating:DX:SingleSpeed   4427.01 3.81
SPLIT GN2_SUPPHEATCOIL Coil:Heating:Electric   4427.01 1.00
SPLIT GS1 HEATING COIL Coil:Heating:DX:SingleSpeed   4521.76 3.81
SPLIT GS1_SUPPHEATCOIL Coil:Heating:Electric   4521.76 1.00
SPLIT GS2 HEATING COIL Coil:Heating:DX:SingleSpeed   4617.61 3.81
SPLIT GS2_SUPPHEATCOIL Coil:Heating:Electric   4617.61 1.00
SPLIT MSW HEATING COIL Coil:Heating:DX:SingleSpeed   12886.90 3.81
SPLIT MSW_SUPPHEATCOIL Coil:Heating:Electric   12886.90 1.00
SPLIT MNW HEATING COIL Coil:Heating:DX:SingleSpeed   12709.01 3.81
SPLIT MNW_SUPPHEATCOIL Coil:Heating:Electric   12709.01 1.00
SPLIT MSE HEATING COIL Coil:Heating:DX:SingleSpeed   11834.39 3.81
SPLIT MSE_SUPPHEATCOIL Coil:Heating:Electric   11834.39 1.00
SPLIT MNE HEATING COIL Coil:Heating:DX:SingleSpeed   11658.90 3.81
SPLIT MNE_SUPPHEATCOIL Coil:Heating:Electric   11658.90 1.00
SPLIT MN1 HEATING COIL Coil:Heating:DX:SingleSpeed   9996.40 3.81
SPLIT MN1_SUPPHEATCOIL Coil:Heating:Electric   9996.40 1.00
SPLIT MN2 HEATING COIL Coil:Heating:DX:SingleSpeed   9978.73 3.81
SPLIT MN2_SUPPHEATCOIL Coil:Heating:Electric   9978.73 1.00
SPLIT MS1 HEATING COIL Coil:Heating:DX:SingleSpeed   10166.68 3.81
SPLIT MS1_SUPPHEATCOIL Coil:Heating:Electric   10166.68 1.00
SPLIT MS2 HEATING COIL Coil:Heating:DX:SingleSpeed   10150.76 3.81
SPLIT MS2_SUPPHEATCOIL Coil:Heating:Electric   10150.76 1.00
SPLIT TSW HEATING COIL Coil:Heating:DX:SingleSpeed   7447.88 3.81
SPLIT TSW_SUPPHEATCOIL Coil:Heating:Electric   7447.88 1.00
SPLIT TNW HEATING COIL Coil:Heating:DX:SingleSpeed   7430.92 3.81
SPLIT TNW_SUPPHEATCOIL Coil:Heating:Electric   7430.92 1.00
SPLIT TSE HEATING COIL Coil:Heating:DX:SingleSpeed   6673.20 3.81
SPLIT TSE_SUPPHEATCOIL Coil:Heating:Electric   6673.20 1.00
SPLIT TNE HEATING COIL Coil:Heating:DX:SingleSpeed   6655.23 3.81
SPLIT TNE_SUPPHEATCOIL Coil:Heating:Electric   6655.23 1.00
SPLIT TN1 HEATING COIL Coil:Heating:DX:SingleSpeed   5977.34 3.81
SPLIT TN1_SUPPHEATCOIL Coil:Heating:Electric   5977.34 1.00
SPLIT TN2 HEATING COIL Coil:Heating:DX:SingleSpeed   5953.31 3.81
SPLIT TN2_SUPPHEATCOIL Coil:Heating:Electric   5953.31 1.00
SPLIT TS1 HEATING COIL Coil:Heating:DX:SingleSpeed   6006.98 3.81
SPLIT TS1_SUPPHEATCOIL Coil:Heating:Electric   6006.98 1.00
SPLIT TS2 HEATING COIL Coil:Heating:DX:SingleSpeed   5983.02 3.81
SPLIT TS2_SUPPHEATCOIL Coil:Heating:Electric   5983.02 1.00
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.

Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electricity Rate [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction Fan Energy Index End Use Subcategory Design Day Name for Fan Sizing Peak Date/Time for Fan Sizing Peak
G SW APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
G SW APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
G NW APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
G NW APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
G NE APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
G NE APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
G N1 APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
G N1 APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
G N2 APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
G N2 APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
G S1 APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
G S1 APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
G S2 APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
G S2 APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
M SW APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.05 44.05 848.65 1.00 3.94 General    
M SW APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.05 44.05 848.65 1.00 3.94 General    
M NW APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.05 44.05 848.65 1.00 3.94 General    
M NW APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.05 44.05 848.65 1.00 3.94 General    
M SE APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.05 44.05 848.65 1.00 3.94 General    
M SE APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.05 44.05 848.65 1.00 3.94 General    
M NE APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.05 44.05 848.65 1.00 3.94 General    
M NE APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.05 44.05 848.65 1.00 3.94 General    
M N1 APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.05 44.05 848.65 1.00 3.94 General    
M N1 APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.05 44.05 848.65 1.00 3.94 General    
M N2 APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.05 44.05 848.65 1.00 3.94 General    
M N2 APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.05 44.05 848.65 1.00 3.94 General    
M S1 APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.05 44.05 848.65 1.00 3.94 General    
M S1 APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.05 44.05 848.65 1.00 3.94 General    
M S2 APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.05 44.05 848.65 1.00 3.94 General    
M S2 APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.05 44.05 848.65 1.00 3.94 General    
T SW APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
T SW APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
T NW APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
T NW APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
T SE APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
T SE APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
T NE APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
T NE APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
T N1 APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
T N1 APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
T N2 APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
T N2 APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
T S1 APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
T S1 APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
T S2 APARTMENT ERV SUP FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
T S2 APARTMENT ERV EXH FAN Fan:OnOff 0.30 257.27 0.03 22.03 848.65 1.00 7.01 General    
SPLIT GSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.34 383.01 1120.11 1.00 1.81 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT GNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.34 376.61 1120.11 1.00 1.82 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT OFFICE SUPPLY FAN Fan:OnOff 0.56 622.50 0.41 458.18 1120.11 1.00 1.70 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 09:20:00
SPLIT GNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.31 349.91 1120.11 1.00 1.87 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT GN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 300.03 1120.11 1.00 1.98 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT GN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 299.56 1120.11 1.00 1.98 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT GS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 305.97 1120.11 1.00 1.97 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT GS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.28 312.45 1120.11 1.00 1.95 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT MSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.78 872.00 1120.11 1.00 1.44 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT MNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.77 859.96 1120.11 1.00 1.45 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT MSE SUPPLY FAN Fan:OnOff 0.56 622.50 0.71 800.78 1120.11 1.00 1.47 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT MNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.70 788.91 1120.11 1.00 1.47 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT MN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.60 676.41 1120.11 1.00 1.53 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT MN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.60 675.22 1120.11 1.00 1.53 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT MS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.61 687.94 1120.11 1.00 1.52 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT MS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.61 686.86 1120.11 1.00 1.52 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT TSW SUPPLY FAN Fan:OnOff 0.56 622.50 0.45 503.97 1120.11 1.00 1.66 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT TNW SUPPLY FAN Fan:OnOff 0.56 622.50 0.45 502.82 1120.11 1.00 1.66 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT TSE SUPPLY FAN Fan:OnOff 0.56 622.50 0.40 451.55 1120.11 1.00 1.71 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT TNE SUPPLY FAN Fan:OnOff 0.56 622.50 0.40 450.33 1120.11 1.00 1.71 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT TN1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.36 404.46 1120.11 1.00 1.77 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT TN2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.36 402.83 1120.11 1.00 1.78 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT TS1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.36 406.47 1120.11 1.00 1.77 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00
SPLIT TS2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.36 404.85 1120.11 1.00 1.77 General TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00


Pumps

Type Control Head [pa] Water Flow [m3/s] Electricity Rate [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W] End Use Subcategory
SWHSYS1 PUMP Pump:ConstantSpeed Intermittent 29891.00 0.000101 12.93 127739.32 0.30 General


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SWHSYS1 WATER HEATER WaterHeater:Mixed 0.95 53912.00 0.80 11.45 0.46



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Zone Sensible Cooling

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
G SW APARTMENT 3665.95 4399.13 49.85 0.285 0.342 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00812 35.61 0.00562 0.026 0.00
G NW APARTMENT 3606.34 4327.60 49.04 0.280 0.336 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00806 35.61 0.00562 0.026 0.00
OFFICE 4217.88 5061.46 57.35 0.341 0.409 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 09:20:00 23.90 23.90 0.00797 34.24 0.00562 0.038 0.00
G NE APARTMENT 3355.40 4026.48 45.63 0.260 0.312 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00806 35.61 0.00562 0.026 0.00
G N1 APARTMENT 2889.45 3467.34 39.29 0.223 0.268 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00811 35.61 0.00562 0.026 0.00
G N2 APARTMENT 2884.99 3461.99 39.23 0.223 0.267 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00811 35.61 0.00562 0.026 0.00
G S1 APARTMENT 2944.64 3533.57 40.04 0.228 0.273 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00826 35.61 0.00562 0.026 0.00
G S2 APARTMENT 3005.44 3606.53 40.87 0.232 0.279 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00825 35.61 0.00562 0.026 0.00
M SW APARTMENT 8319.58 9983.50 113.13 0.649 0.778 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00808 35.61 0.00562 0.052 0.00
M NW APARTMENT 8207.16 9848.59 111.60 0.640 0.768 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00803 35.61 0.00562 0.052 0.00
M SE APARTMENT 7655.17 9186.20 104.09 0.596 0.715 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00810 35.61 0.00562 0.052 0.00
M NE APARTMENT 7544.72 9053.67 102.59 0.587 0.704 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00804 35.61 0.00562 0.052 0.00
M N1 APARTMENT 6492.57 7791.08 88.28 0.503 0.604 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00808 35.61 0.00562 0.052 0.00
M N2 APARTMENT 6481.33 7777.60 88.13 0.502 0.603 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00808 35.61 0.00562 0.052 0.00
M S1 APARTMENT 6599.61 7919.53 89.74 0.512 0.614 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00820 35.61 0.00562 0.052 0.00
M S2 APARTMENT 6589.52 7907.43 89.60 0.511 0.613 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00820 35.61 0.00562 0.052 0.00
T SW APARTMENT 4799.35 5759.22 65.26 0.375 0.450 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00804 35.61 0.00562 0.026 0.00
T NW APARTMENT 4788.63 5746.36 65.12 0.374 0.449 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00802 35.61 0.00562 0.026 0.00
T SE APARTMENT 4307.86 5169.43 58.58 0.336 0.403 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00805 35.61 0.00562 0.026 0.00
T NE APARTMENT 4296.30 5155.55 58.42 0.335 0.402 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00802 35.61 0.00562 0.026 0.00
T N1 APARTMENT 3867.13 4640.55 52.58 0.301 0.361 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00805 35.61 0.00562 0.026 0.00
T N2 APARTMENT 3851.94 4622.33 52.38 0.300 0.360 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00805 35.61 0.00562 0.026 0.00
T S1 APARTMENT 3885.96 4663.15 52.84 0.302 0.363 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00809 35.61 0.00562 0.026 0.00
T S2 APARTMENT 3870.81 4644.98 52.63 0.301 0.361 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.00 24.00 0.00809 35.61 0.00562 0.026 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

Zone Sensible Heating

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
G SW APARTMENT 798.97 958.77 10.86 0.038 0.046 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 21.10 21.10 0.00783 0.50 0.00432 0.026 0.00
G NW APARTMENT 672.59 807.11 9.15 0.032 0.038 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 21.10 21.10 0.00825 0.50 0.00432 0.026 0.00
OFFICE 1229.08 1474.90 16.71 0.058 0.070 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 18:50:00 21.10 21.10 0.00789 0.50 0.00432 0.038 0.00
G NE APARTMENT 674.78 809.73 9.18 0.032 0.038 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 21.10 21.10 0.00825 0.50 0.00432 0.026 0.00
G N1 APARTMENT 335.29 402.35 4.56 0.016 0.026 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 21.10 21.10 0.00862 0.50 0.00432 0.026 0.00
G N2 APARTMENT 335.36 402.44 4.56 0.016 0.026 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 21.10 21.10 0.00862 0.50 0.00432 0.026 0.00
G S1 APARTMENT 461.92 554.31 6.28 0.022 0.026 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 21.10 21.10 0.00781 0.50 0.00432 0.026 0.00
G S2 APARTMENT 473.59 568.31 6.44 0.022 0.027 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 21.10 21.10 0.00782 0.50 0.00432 0.026 0.00
M SW APARTMENT 1819.81 2183.77 24.75 0.086 0.104 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 21.10 21.10 0.00779 0.50 0.00432 0.052 0.00
M NW APARTMENT 1530.38 1836.46 20.81 0.073 0.087 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 21.10 21.10 0.00815 0.50 0.00432 0.052 0.00
M SE APARTMENT 1825.16 2190.19 24.82 0.087 0.104 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 21.10 21.10 0.00779 0.50 0.00432 0.052 0.00
M NE APARTMENT 1535.82 1842.98 20.88 0.073 0.087 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 21.10 21.10 0.00815 0.50 0.00432 0.052 0.00
M N1 APARTMENT 679.23 815.08 9.24 0.032 0.052 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 21.10 21.10 0.00851 0.50 0.00432 0.052 0.00
M N2 APARTMENT 679.39 815.26 9.24 0.032 0.052 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 21.10 21.10 0.00851 0.50 0.00432 0.052 0.00
M S1 APARTMENT 960.54 1152.65 13.06 0.046 0.055 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 21.10 21.10 0.00774 0.50 0.00432 0.052 0.00
M S2 APARTMENT 960.69 1152.83 13.06 0.046 0.055 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 21.10 21.10 0.00774 0.50 0.00432 0.052 0.00
T SW APARTMENT 1628.81 1954.57 22.15 0.077 0.093 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 21.10 21.10 0.00784 0.50 0.00432 0.026 0.00
T NW APARTMENT 1473.10 1767.73 20.03 0.070 0.084 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 21.10 21.10 0.00804 0.50 0.00432 0.026 0.00
T SE APARTMENT 1631.88 1958.26 22.19 0.077 0.093 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 21.10 21.10 0.00784 0.50 0.00432 0.026 0.00
T NE APARTMENT 1476.26 1771.51 20.07 0.070 0.084 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 21.10 21.10 0.00804 0.50 0.00432 0.026 0.00
T N1 APARTMENT 1003.21 1203.85 13.64 0.048 0.057 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 21.10 21.10 0.00816 0.50 0.00432 0.026 0.00
T N2 APARTMENT 1003.31 1203.97 13.64 0.048 0.057 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 21.10 21.10 0.00816 0.50 0.00432 0.026 0.00
T S1 APARTMENT 1159.53 1391.44 15.77 0.055 0.066 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 21.10 21.10 0.00786 0.50 0.00432 0.026 0.00
T S2 APARTMENT 1159.63 1391.55 15.77 0.055 0.066 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 21.10 21.10 0.00786 0.50 0.00432 0.026 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s] Adjusted cooling [m3/s] Adjusted heating [m3/s] Adjusted main [m3/s] Calculated Heating Air Flow Ratio [] User Heating Air Flow Ratio []
SPLIT GSW 0.34 0.34 0.05 0.05 0.3419 0.3419 0.3419 1.0000 1.0000
SPLIT GNW 0.34 0.34 0.04 0.04 0.3362 0.3362 0.3362 1.0000 1.0000
SPLIT OFFICE 0.41 0.41 0.07 0.07 0.4090 0.4090 0.4090 1.0000 1.0000
SPLIT GNE 0.31 0.31 0.04 0.04 0.3124 0.3124 0.3124 1.0000 1.0000
SPLIT GN1 0.27 0.27 0.03 0.03 0.2679 0.2679 0.2679 1.0000 1.0000
SPLIT GN2 0.27 0.27 0.03 0.03 0.2674 0.2674 0.2674 1.0000 1.0000
SPLIT GS1 0.27 0.27 0.03 0.03 0.2732 0.2732 0.2732 1.0000 1.0000
SPLIT GS2 0.28 0.28 0.03 0.03 0.2789 0.2789 0.2789 1.0000 1.0000
SPLIT MSW 0.78 0.78 0.10 0.10 0.7785 0.7785 0.7785 1.0000 1.0000
SPLIT MNW 0.77 0.77 0.09 0.09 0.7678 0.7678 0.7678 1.0000 1.0000
SPLIT MSE 0.71 0.71 0.10 0.10 0.7149 0.7149 0.7149 1.0000 1.0000
SPLIT MNE 0.70 0.70 0.09 0.09 0.7043 0.7043 0.7043 1.0000 1.0000
SPLIT MN1 0.60 0.60 0.05 0.05 0.6039 0.6039 0.6039 1.0000 1.0000
SPLIT MN2 0.60 0.60 0.05 0.05 0.6028 0.6028 0.6028 1.0000 1.0000
SPLIT MS1 0.61 0.61 0.05 0.05 0.6142 0.6142 0.6142 1.0000 1.0000
SPLIT MS2 0.61 0.61 0.05 0.05 0.6132 0.6132 0.6132 1.0000 1.0000
SPLIT TSW 0.45 0.45 0.09 0.09 0.4499 0.4499 0.4499 1.0000 1.0000
SPLIT TNW 0.45 0.45 0.08 0.08 0.4489 0.4489 0.4489 1.0000 1.0000
SPLIT TSE 0.40 0.40 0.09 0.09 0.4031 0.4031 0.4031 1.0000 1.0000
SPLIT TNE 0.40 0.40 0.08 0.08 0.4020 0.4020 0.4020 1.0000 1.0000
SPLIT TN1 0.36 0.36 0.06 0.06 0.3611 0.3611 0.3611 1.0000 1.0000
SPLIT TN2 0.36 0.36 0.06 0.06 0.3596 0.3596 0.3596 1.0000 1.0000
SPLIT TS1 0.36 0.36 0.07 0.07 0.3629 0.3629 0.3629 1.0000 1.0000
SPLIT TS2 0.36 0.36 0.07 0.07 0.3614 0.3614 0.3614 1.0000 1.0000


Plant Loop Coincident Design Fluid Flow Rate Adjustments

Previous Design Volume Flow Rate [m3/s] Algorithm Volume Flow Rate [m3/s] Coincident Design Volume Flow Rate [m3/s] Coincident Size Adjusted Peak Sizing Period Name Peak Day into Period {TIMESTAMP}[day] Peak Hour Of Day {TIMESTAMP}[hr] Peak Step Start Minute {TIMESTAMP}[min]
None                


Coil Sizing Summary

Coil Type HVAC Type HVAC Name Coil Final Gross Total Capacity [W] Coil Final Gross Sensible Capacity [W] Coil Final Reference Air Volume Flow Rate [m3/s] Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] Coil U-value Times Area Value [W/K] Design Day Name at Sensible Ideal Loads Peak Date/Time at Sensible Ideal Loads Peak Design Day Name at Air Flow Ideal Loads Peak Date/Time at Air Flow Ideal Loads Peak Coil Total Capacity at Ideal Loads Peak [W] Coil Sensible Capacity at Ideal Loads Peak [W] Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] Coil Entering Air Drybulb at Ideal Loads Peak [C] Coil Entering Air Wetbulb at Ideal Loads Peak [C] Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Leaving Air Drybulb at Ideal Loads Peak [C] Coil Leaving Air Wetbulb at Ideal Loads Peak [C] Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Drybulb at Ideal Loads Peak [C] Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Wetbulb at Ideal Loads Peak [C] Outdoor Air Flow Percentage at Ideal Loads Peak [%] Zone Air Drybulb at Ideal Loads Peak [C] Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Relative Humidity at Ideal Loads Peak [%] Zone Sensible Heat Gain at Ideal Loads Peak [W] Zone Latent Heat Gain at Ideal Loads Peak [W] Coil Total Capacity at Rating Conditions [W] Coil Sensible Capacity at Rating Conditions [W]
SPLIT GSW HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT GSW 5660.355 4531.993 0.341942 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 5070.06 5070.06 0.341942 25.92 15.59 0.00793295 12.80 10.67 0.00793295 35.61 0.00562306 16.94 7.5903 24.00 0.00812268 39.7205 3665.95 0.00 5659.39 4308.81
SPLIT GSW HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT GSW 5660.355 5660.355 0.341942 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 5660.35 5660.35 0.341942 19.54 12.97 0.00756190 40.00 20.06 0.00800000 0.50 0.00431558 0.50 7.5903 21.10 0.00782854 45.6765 798.97 0.00 5667.79 5667.79
SPLIT GSW_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT GSW 5660.355 5660.355 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 5660.35 5660.35 0.341942 19.54 12.97 0.00756190 40.00 20.06 0.00800000 0.50 0.00431558 0.50 7.5903 21.10 0.00782854 45.6765 798.97 0.00 -999.00 -999.00
SPLIT GNW HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT GNW 5565.769 4456.262 0.336228 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 4978.61 4978.61 0.336228 25.94 15.54 0.00787096 12.80 10.61 0.00787096 35.61 0.00562306 16.94 7.7193 24.00 0.00805900 39.4124 3606.34 0.00 5564.82 4236.81
SPLIT GNW HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT GNW 5565.769 5565.769 0.336228 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 5565.77 5565.77 0.336228 19.51 13.31 0.00794975 40.00 20.06 0.00800000 0.50 0.00431558 0.50 7.7193 21.10 0.00825375 48.1237 672.59 0.00 5573.08 5573.08
SPLIT GNW_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT GNW 5565.769 5565.769 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 5565.77 5565.77 0.336228 19.51 13.31 0.00794975 40.00 20.06 0.00800000 0.50 0.00431558 0.50 7.7193 21.10 0.00825375 48.1237 672.59 0.00 -999.00 -999.00
SPLIT OFFICE HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT OFFICE 6771.158 5421.363 0.409046 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 12:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 09:20:00 6127.07 6127.07 0.409046 25.87 15.42 0.00775420 12.80 10.50 0.00775420 34.24 0.00562096 16.49 9.3158 23.90 0.00797463 39.2393 4148.34 0.00 6770.01 5154.39
SPLIT OFFICE HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT OFFICE 6771.158 6771.158 0.409046 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 18:50:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 18:50:00 6771.16 6771.16 0.409046 19.18 12.82 0.00755345 40.00 20.06 0.00800000 0.50 0.00431558 0.50 9.3158 21.10 0.00788607 46.0077 1229.08 0.00 6780.06 6780.06
SPLIT OFFICE_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT OFFICE 6771.158 6771.158 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 18:50:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 18:50:00 6771.16 6771.16 0.409046 19.18 12.82 0.00755345 40.00 20.06 0.00800000 0.50 0.00431558 0.50 9.3158 21.10 0.00788607 46.0077 1229.08 0.00 -999.00 -999.00
SPLIT GNE HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT GNE 5171.095 4140.265 0.312386 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 4627.35 4627.35 0.312386 26.00 15.56 0.00786191 12.80 10.60 0.00786191 35.61 0.00562306 16.94 8.3085 24.00 0.00806478 39.4403 3355.40 0.00 5170.22 3936.38
SPLIT GNE HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT GNE 5171.095 5171.095 0.312386 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 5171.10 5171.10 0.312386 19.39 13.24 0.00792588 40.00 20.06 0.00800000 0.50 0.00431558 0.50 8.3085 21.10 0.00825302 48.1195 674.78 0.00 5177.89 5177.89
SPLIT GNE_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT GNE 5171.095 5171.095 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 5171.10 5171.10 0.312386 19.39 13.24 0.00792588 40.00 20.06 0.00800000 0.50 0.00431558 0.50 8.3085 21.10 0.00825302 48.1195 674.78 0.00 -999.00 -999.00
SPLIT GN1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT GN1 4434.002 3550.107 0.267858 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 3974.32 3974.32 0.267858 26.14 15.61 0.00787160 12.80 10.61 0.00787160 35.61 0.00562306 16.94 9.6897 24.00 0.00811285 39.6727 2889.45 0.00 4433.25 3375.28
SPLIT GN1 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT GN1 4434.002 4434.002 0.267858 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 4434.00 4434.00 0.267858 19.10 13.39 0.00820571 40.00 20.06 0.00800000 0.50 0.00431558 0.50 9.6897 21.10 0.00855208 49.8396 291.37 0.00 4439.83 4439.83
SPLIT GN1_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT GN1 4434.002 4434.002 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 4434.00 4434.00 0.267858 19.10 13.39 0.00820571 40.00 20.06 0.00800000 0.50 0.00431558 0.50 9.6897 21.10 0.00855208 49.8396 291.37 0.00 -999.00 -999.00
SPLIT GN2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT GN2 4427.010 3544.509 0.267436 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 3968.09 3968.09 0.267436 26.15 15.61 0.00787138 12.80 10.61 0.00787138 35.61 0.00562306 16.94 9.7050 24.00 0.00811303 39.6735 2884.99 0.00 4426.26 3369.96
SPLIT GN2 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT GN2 4427.010 4427.010 0.267436 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 4427.01 4427.01 0.267436 19.10 13.39 0.00820495 40.00 20.06 0.00800000 0.50 0.00431558 0.50 9.7050 21.10 0.00855199 49.8390 291.44 0.00 4432.83 4432.83
SPLIT GN2_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT GN2 4427.010 4427.010 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 4427.01 4427.01 0.267436 19.10 13.39 0.00820495 40.00 20.06 0.00800000 0.50 0.00431558 0.50 9.7050 21.10 0.00855199 49.8390 291.44 0.00 -999.00 -999.00
SPLIT GS1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT GS1 4521.762 3620.372 0.273160 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 4065.28 4060.77 0.273160 26.12 15.72 0.00800750 12.80 10.74 0.00800000 35.61 0.00562306 16.94 9.5016 24.00 0.00825784 40.3736 2944.64 0.00 4520.99 3442.09
SPLIT GS1 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT GS1 4521.762 4521.762 0.273160 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 4521.76 4521.76 0.273160 19.14 12.74 0.00747793 40.00 20.06 0.00800000 0.50 0.00431558 0.50 9.5016 21.10 0.00780995 45.5692 461.92 0.00 4527.70 4527.70
SPLIT GS1_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT GS1 4521.762 4521.762 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 4521.76 4521.76 0.273160 19.14 12.74 0.00747793 40.00 20.06 0.00800000 0.50 0.00431558 0.50 9.5016 21.10 0.00780995 45.5692 461.92 0.00 -999.00 -999.00
SPLIT GS2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT GS2 4617.610 3697.114 0.278950 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 4150.63 4146.40 0.278950 26.10 15.71 0.00800686 12.80 10.74 0.00800000 35.61 0.00562306 16.94 9.3044 24.00 0.00825142 40.3426 3005.44 0.00 4616.82 3515.05
SPLIT GS2 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT GS2 4617.610 4617.610 0.278950 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 4617.61 4617.61 0.278950 19.18 12.77 0.00748981 40.00 20.06 0.00800000 0.50 0.00431558 0.50 9.3044 21.10 0.00781545 45.6009 473.59 0.00 4623.68 4623.68
SPLIT GS2_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT GS2 4617.610 4617.610 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 4617.61 4617.61 0.278950 19.18 12.77 0.00748981 40.00 20.06 0.00800000 0.50 0.00431558 0.50 9.3044 21.10 0.00781545 45.6009 473.59 0.00 -999.00 -999.00
SPLIT MSW HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT MSW 12886.898 10317.963 0.778498 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 11526.87 11526.87 0.778498 25.83 15.54 0.00791575 12.80 10.66 0.00791575 35.61 0.00562306 16.94 6.6679 24.00 0.00807954 39.5118 16639.17 0.00 12884.71 9809.85
SPLIT MSW HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT MSW 12886.898 12886.898 0.778498 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 12886.90 12886.90 0.778498 19.73 13.03 0.00755588 40.00 20.06 0.00800000 0.50 0.00431558 0.50 6.6679 21.10 0.00778737 45.4394 3639.62 0.00 12903.83 12903.83
SPLIT MSW_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT MSW 12886.898 12886.898 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 12886.90 12886.90 0.778498 19.73 13.03 0.00755588 40.00 20.06 0.00800000 0.50 0.00431558 0.50 6.6679 21.10 0.00778737 45.4394 3639.62 0.00 -999.00 -999.00
SPLIT MNW HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT MNW 12709.010 10175.536 0.767751 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 11356.68 11356.68 0.767751 25.84 15.51 0.00787115 12.80 10.61 0.00787115 35.61 0.00562306 16.94 6.7612 24.00 0.00803416 39.2923 16414.32 0.00 12706.85 9674.44
SPLIT MNW HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT MNW 12709.010 12709.010 0.767751 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 12709.01 12709.01 0.767751 19.71 13.33 0.00788782 40.00 20.06 0.00800000 0.50 0.00431558 0.50 6.7612 21.10 0.00814686 47.5088 3060.77 0.00 12725.71 12725.71
SPLIT MNW_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT MNW 12709.010 12709.010 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 12709.01 12709.01 0.767751 19.71 13.33 0.00788782 40.00 20.06 0.00800000 0.50 0.00431558 0.50 6.7612 21.10 0.00814686 47.5088 3060.77 0.00 -999.00 -999.00
SPLIT MSE HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT MSE 11834.394 9475.270 0.714916 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 10593.09 10593.09 0.714916 25.89 15.57 0.00791945 12.80 10.66 0.00791945 35.61 0.00562306 16.94 7.2609 24.00 0.00809925 39.6071 15310.33 0.00 11832.38 9008.66
SPLIT MSE HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT MSE 11834.394 11834.394 0.714916 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 11834.39 11834.39 0.714916 19.60 12.97 0.00753586 40.00 20.06 0.00800000 0.50 0.00431558 0.50 7.2609 21.10 0.00778799 45.4429 3650.32 0.00 11849.95 11849.95
SPLIT MSE_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT MSE 11834.394 11834.394 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 11834.39 11834.39 0.714916 19.60 12.97 0.00753586 40.00 20.06 0.00800000 0.50 0.00431558 0.50 7.2609 21.10 0.00778799 45.4429 3650.32 0.00 -999.00 -999.00
SPLIT MNE HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT MNE 11658.897 9334.757 0.704314 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 10422.01 10422.01 0.704314 25.90 15.52 0.00785878 12.80 10.60 0.00785878 35.61 0.00562306 16.94 7.3702 24.00 0.00803667 39.3043 15089.45 0.00 11656.91 8875.07
SPLIT MNE HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT MNE 11658.897 11658.897 0.704314 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 11658.90 11658.90 0.704314 19.58 13.26 0.00786406 40.00 20.06 0.00800000 0.50 0.00431558 0.50 7.3702 21.10 0.00814640 47.5061 3071.63 0.00 11674.22 11674.22
SPLIT MNE_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT MNE 11658.897 11658.897 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 11658.90 11658.90 0.704314 19.58 13.26 0.00786406 40.00 20.06 0.00800000 0.50 0.00431558 0.50 7.3702 21.10 0.00814640 47.5061 3071.63 0.00 -999.00 -999.00
SPLIT MN1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT MN1 9996.402 8003.672 0.603883 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 8949.79 8949.79 0.603883 26.03 15.57 0.00786980 12.80 10.61 0.00786980 35.61 0.00562306 16.94 8.5959 24.00 0.00808109 39.5191 12985.13 0.00 9994.70 7609.53
SPLIT MN1 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT MN1 9996.402 9996.402 0.603883 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 17:50:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 17:50:00 9996.40 9996.40 0.603883 19.33 13.43 0.00815312 40.00 20.06 0.00800000 0.50 0.00431558 0.50 8.5959 21.10 0.00800860 46.7131 754.36 0.00 10009.54 10009.54
SPLIT MN1_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT MN1 9996.402 9996.402 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 17:50:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 17:50:00 9996.40 9996.40 0.603883 19.33 13.43 0.00815312 40.00 20.06 0.00800000 0.50 0.00431558 0.50 8.5959 21.10 0.00800860 46.7131 754.36 0.00 -999.00 -999.00
SPLIT MN2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT MN2 9978.728 7989.521 0.602815 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 8934.04 8934.04 0.602815 26.03 15.57 0.00786954 12.80 10.61 0.00786954 35.61 0.00562306 16.94 8.6111 24.00 0.00808122 39.5197 12962.66 0.00 9977.03 7596.08
SPLIT MN2 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT MN2 9978.728 9978.728 0.602815 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 17:40:00 9978.73 9978.73 0.602815 19.33 13.43 0.00815240 40.00 20.06 0.00800000 0.50 0.00431558 0.50 8.6111 21.10 0.00843555 49.1697 1084.13 0.00 9991.84 9991.84
SPLIT MN2_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT MN2 9978.728 9978.728 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 17:40:00 9978.73 9978.73 0.602815 19.33 13.43 0.00815240 40.00 20.06 0.00800000 0.50 0.00431558 0.50 8.6111 21.10 0.00843555 49.1697 1084.13 0.00 -999.00 -999.00
SPLIT MS1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT MS1 10166.683 8140.008 0.614169 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 9125.51 9125.51 0.614169 26.01 15.66 0.00798332 12.80 10.72 0.00798332 35.61 0.00562306 16.94 8.4519 24.00 0.00820123 40.1000 13199.22 0.00 10164.95 7739.15
SPLIT MS1 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT MS1 10166.683 10166.683 0.614169 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 10166.68 10166.68 0.614169 19.36 12.80 0.00744931 40.00 20.06 0.00800000 0.50 0.00431558 0.50 8.4519 21.10 0.00773862 45.1582 1921.09 0.00 10180.04 10180.04
SPLIT MS1_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT MS1 10166.683 10166.683 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 10166.68 10166.68 0.614169 19.36 12.80 0.00744931 40.00 20.06 0.00800000 0.50 0.00431558 0.50 8.4519 21.10 0.00773862 45.1582 1921.09 0.00 -999.00 -999.00
SPLIT MS2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT MS2 10150.758 8127.258 0.613207 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 9111.34 9111.34 0.613207 26.02 15.66 0.00798331 12.80 10.72 0.00798331 35.61 0.00562306 16.94 8.4652 24.00 0.00820159 40.1017 13179.04 0.00 10149.03 7727.03
SPLIT MS2 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT MS2 10150.758 10150.758 0.613207 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 10150.76 10150.76 0.613207 19.36 12.79 0.00744890 40.00 20.06 0.00800000 0.50 0.00431558 0.50 8.4652 21.10 0.00773867 45.1585 1921.38 0.00 10164.10 10164.10
SPLIT MS2_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT MS2 10150.758 10150.758 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 10150.76 10150.76 0.613207 19.36 12.79 0.00744890 40.00 20.06 0.00800000 0.50 0.00431558 0.50 8.4652 21.10 0.00773867 45.1585 1921.38 0.00 -999.00 -999.00
SPLIT TSW HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT TSW 7447.880 5963.185 0.449926 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 6653.29 6653.29 0.449926 25.73 15.50 0.00790000 12.80 10.64 0.00790000 35.61 0.00562306 16.94 5.7686 24.00 0.00803939 39.3176 4799.35 0.00 7446.61 5669.53
SPLIT TSW HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT TSW 7447.880 7447.880 0.449926 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 7447.88 7447.88 0.449926 19.91 13.18 0.00763917 40.00 20.06 0.00800000 0.50 0.00431558 0.50 5.7686 21.10 0.00784264 45.7580 1628.81 0.00 7457.67 7457.67
SPLIT TSW_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT TSW 7447.880 7447.880 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 7447.88 7447.88 0.449926 19.91 13.18 0.00763917 40.00 20.06 0.00800000 0.50 0.00431558 0.50 5.7686 21.10 0.00784264 45.7580 1628.81 0.00 -999.00 -999.00
SPLIT TNW HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT TNW 7430.922 5949.607 0.448902 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 6634.74 6634.74 0.448902 25.74 15.48 0.00787820 12.80 10.62 0.00787820 35.61 0.00562306 16.94 5.7818 24.00 0.00801658 39.2072 4788.63 0.00 7429.66 5656.62
SPLIT TNW HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT TNW 7430.922 7430.922 0.448902 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 7430.92 7430.92 0.448902 19.91 13.34 0.00782089 40.00 20.06 0.00800000 0.50 0.00431558 0.50 5.7818 21.10 0.00803600 46.8708 1473.10 0.00 7440.69 7440.69
SPLIT TNW_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT TNW 7430.922 7430.922 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 7430.92 7430.92 0.448902 19.91 13.34 0.00782089 40.00 20.06 0.00800000 0.50 0.00431558 0.50 5.7818 21.10 0.00803600 46.8708 1473.10 0.00 -999.00 -999.00
SPLIT TSE HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT TSE 6673.203 5342.935 0.403128 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 5964.40 5964.40 0.403128 25.81 15.51 0.00789241 12.80 10.63 0.00789241 35.61 0.00562306 16.94 6.4383 24.00 0.00804857 39.3620 4307.86 0.00 6672.07 5079.82
SPLIT TSE HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT TSE 6673.203 6673.203 0.403128 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 6673.20 6673.20 0.403128 19.77 13.11 0.00761582 40.00 20.06 0.00800000 0.50 0.00431558 0.50 6.4383 21.10 0.00784292 45.7597 1631.88 0.00 6681.97 6681.97
SPLIT TSE_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT TSE 6673.203 6673.203 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 6673.20 6673.20 0.403128 19.77 13.11 0.00761582 40.00 20.06 0.00800000 0.50 0.00431558 0.50 6.4383 21.10 0.00784292 45.7597 1631.88 0.00 -999.00 -999.00
SPLIT TNE HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT TNE 6655.227 5328.543 0.402042 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 5944.26 5944.26 0.402042 25.81 15.49 0.00786332 12.80 10.60 0.00786332 35.61 0.00562306 16.94 6.4557 24.00 0.00801792 39.2137 4296.30 0.00 6654.09 5066.14
SPLIT TNE HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT TNE 6655.227 6655.227 0.402042 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 6655.23 6655.23 0.402042 19.77 13.27 0.00779575 40.00 20.06 0.00800000 0.50 0.00431558 0.50 6.4557 21.10 0.00803593 46.8703 1476.26 0.00 6663.97 6663.97
SPLIT TNE_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT TNE 6655.227 6655.227 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 6655.23 6655.23 0.402042 19.77 13.27 0.00779575 40.00 20.06 0.00800000 0.50 0.00431558 0.50 6.4557 21.10 0.00803593 46.8703 1476.26 0.00 -999.00 -999.00
SPLIT TN1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT TN1 5977.341 4785.789 0.361091 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 5344.28 5344.28 0.361091 25.89 15.53 0.00787335 12.80 10.61 0.00787335 35.61 0.00562306 16.94 7.1878 24.00 0.00804763 39.3573 3867.13 0.00 5976.32 4550.11
SPLIT TN1 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT TN1 5977.341 5977.341 0.361091 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 5977.34 5977.34 0.361091 19.62 13.29 0.00787931 40.00 20.06 0.00800000 0.50 0.00431558 0.50 7.1878 21.10 0.00815530 47.5572 1003.21 0.00 5985.20 5985.20
SPLIT TN1_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT TN1 5977.341 5977.341 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 5977.34 5977.34 0.361091 19.62 13.29 0.00787931 40.00 20.06 0.00800000 0.50 0.00431558 0.50 7.1878 21.10 0.00815530 47.5572 1003.21 0.00 -999.00 -999.00
SPLIT TN2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT TN2 5953.308 4766.547 0.359639 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 5322.89 5322.89 0.359639 25.89 15.53 0.00787284 12.80 10.61 0.00787284 35.61 0.00562306 16.94 7.2168 24.00 0.00804783 39.3583 3851.94 0.00 5952.29 4531.82
SPLIT TN2 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT TN2 5953.308 5953.308 0.359639 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 5953.31 5953.31 0.359639 19.61 13.28 0.00787818 40.00 20.06 0.00800000 0.50 0.00431558 0.50 7.2168 21.10 0.00815529 47.5571 1003.31 0.00 5961.13 5961.13
SPLIT TN2_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT TN2 5953.308 5953.308 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 5953.31 5953.31 0.359639 19.61 13.28 0.00787818 40.00 20.06 0.00800000 0.50 0.00431558 0.50 7.2168 21.10 0.00815529 47.5571 1003.31 0.00 -999.00 -999.00
SPLIT TS1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT TS1 6006.983 4809.522 0.362882 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 5375.76 5375.76 0.362882 25.88 15.56 0.00791338 12.80 10.65 0.00791338 35.61 0.00562306 16.94 7.1523 24.00 0.00808981 39.5614 3885.96 0.00 6005.96 4572.68
SPLIT TS1 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT TS1 6006.983 6006.983 0.362882 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 6006.98 6006.98 0.362882 19.63 13.05 0.00761108 40.00 20.06 0.00800000 0.50 0.00431558 0.50 7.1523 21.10 0.00786494 45.8862 1159.53 0.00 6014.88 6014.88
SPLIT TS1_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT TS1 6006.983 6006.983 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 6006.98 6006.98 0.362882 19.63 13.05 0.00761108 40.00 20.06 0.00800000 0.50 0.00431558 0.50 7.1523 21.10 0.00786494 45.8862 1159.53 0.00 -999.00 -999.00
SPLIT TS2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC SPLIT TS2 5983.022 4790.338 0.361434 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 5354.46 5354.46 0.361434 25.89 15.56 0.00791325 12.80 10.65 0.00791325 35.61 0.00562306 16.94 7.1810 24.00 0.00809043 39.5644 3870.81 0.00 5982.00 4554.44
SPLIT TS2 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoopHVAC SPLIT TS2 5983.022 5983.022 0.361434 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 5983.02 5983.02 0.361434 19.62 13.04 0.00761007 40.00 20.06 0.00800000 0.50 0.00431558 0.50 7.1810 21.10 0.00786495 45.8863 1159.63 0.00 5990.88 5990.88
SPLIT TS2_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoopHVAC SPLIT TS2 5983.022 5983.022 -999.0 -999.0 -999.000 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 5983.02 5983.02 0.361434 19.62 13.04 0.00761007 40.00 20.06 0.00800000 0.50 0.00431558 0.50 7.1810 21.10 0.00786495 45.8863 1159.63 0.00 -999.00 -999.00



Table of Contents

Report: Coil Sizing Details

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Coils

Coil Type Coil Location HVAC Type HVAC Name Zone Name(s) System Sizing Method Concurrence System Sizing Method Capacity System Sizing Method Air Flow Autosized Coil Capacity? Autosized Coil Airflow? Autosized Coil Water Flow? OA Pretreated prior to coil inlet? Coil Final Gross Total Capacity [W] Coil Final Gross Sensible Capacity [W] Coil Final Reference Air Volume Flow Rate [m3/s] Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] Coil U-value Times Area Value [W/K] Terminal Unit Reheat Coil Multiplier DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio Moist Air Heat Capacity [J/kg-K] Dry Air Heat Capacity [J/kg-K] Standard Air Density Adjusted for Elevation [kg/m3] Supply Fan Name for Coil Supply Fan Type for Coil Supply Fan Maximum Air Volume Flow Rate [m3/s] Supply Fan Maximum Air Mass Flow Rate [kg/s] Plant Name for Coil Plant Fluid Specific Heat Capacity [J/kg-K] Plant Fluid Density [kg/m3] Plant Maximum Fluid Mass Flow Rate [kg/s] Plant Design Fluid Return Temperature [C] Plant Design Fluid Supply Temperature [C] Plant Design Fluid Temperature Difference [deltaC] Plant Design Capacity [W] Coil Capacity Percentage of Plant Design Capacity [%] Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] Design Day Name at Sensible Ideal Loads Peak Date/Time at Sensible Ideal Loads Peak Design Day Name at Total Ideal Loads Peak Date/Time at Total Ideal Loads Peak Design Day Name at Air Flow Ideal Loads Peak Date/Time at Air Flow Ideal Loads Peak Peak Load Type to Size On Coil Total Capacity at Ideal Loads Peak [W] Coil Sensible Capacity at Ideal Loads Peak [W] Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] Coil Entering Air Drybulb at Ideal Loads Peak [C] Coil Entering Air Wetbulb at Ideal Loads Peak [C] Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] Coil Leaving Air Drybulb at Ideal Loads Peak [C] Coil Leaving Air Wetbulb at Ideal Loads Peak [C] Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] Supply Fan Air Heat Gain at Ideal Loads Peak [W] Coil and Fan Net Total Capacity at Ideal Loads Peak [W] Outdoor Air Drybulb at Ideal Loads Peak [C] Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Wetbulb at Ideal Loads Peak [C] Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] Outdoor Air Flow Percentage at Ideal Loads Peak [%] System Return Air Drybulb at Ideal Loads Peak [C] System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Drybulb at Ideal Loads Peak [C] Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Relative Humidity at Ideal Loads Peak [%] Zone Sensible Heat Gain at Ideal Loads Peak [W] Zone Latent Heat Gain at Ideal Loads Peak [W] Coil Total Capacity at Rating Conditions [W] Coil Sensible Capacity at Rating Conditions [W] Coil Air Mass Flow Rate at Rating Conditions [kg/s] Coil Entering Air Drybulb at Rating Conditions [C] Coil Entering Air Wetbulb at Rating Conditions [C] Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] Coil Leaving Air Drybulb at Rating Conditions [C] Coil Leaving Air Wetbulb at Rating Conditions [C] Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K]
SPLIT GSW HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT GSW G SW APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 5660.355 4531.993 0.341942 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.5870 1004.8586 1.0932 SPLIT GSW SUPPLY FAN Fan:OnOff 0.341942 0.37380906   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 5070.06 5070.06 0.8957 0.37380906 0.341942 25.92 15.59 0.00793295 46272.5 12.80 10.67 0.00793295 32890.6 -999.0 -999.00 -999.00 -999.00 383.012 4687.05 35.61 0.00562306 16.94 0.02595455 7.5903 24.04 0.00812268 24.00 0.00812268 39.7205 3665.95 0.00 5659.39 4308.81 0.35904643 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT GSW HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT GSW G SW APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 5660.355 5660.355 0.341942 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT GSW SUPPLY FAN Fan:OnOff 0.341942 0.37380906   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 Sensible 5660.35 5660.35 1.0000 0.37380906 0.341942 19.54 12.97 0.00756190 38817.3 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 5660.35 0.50 0.00431558 0.50 0.02595455 7.5903 21.10 0.00782854 21.10 0.00782854 45.6765 798.97 0.00 5667.79 5667.79 0.36720374 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT GSW_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT GSW G SW APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 5660.355 5660.355 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT GSW SUPPLY FAN Fan:OnOff 0.341942 0.37380906   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 Sensible 5660.35 5660.35 1.0000 0.37380906 0.341942 19.54 12.97 0.00756190 38817.3 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 5660.35 0.50 0.00431558 0.50 0.02595455 7.5903 21.10 0.00782854 21.10 0.00782854 45.6765 798.97 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT GNW HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT GNW G NW APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 5565.769 4456.262 0.336228 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.4717 1004.8586 1.0932 SPLIT GNW SUPPLY FAN Fan:OnOff 0.336228 0.36756263   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 4978.61 4978.61 0.8945 0.36756263 0.336228 25.94 15.54 0.00787096 46128.8 12.80 10.61 0.00787096 32734.0 -999.0 -999.00 -999.00 -999.00 376.612 4601.99 35.61 0.00562306 16.94 0.02595455 7.7193 24.04 0.00805900 24.00 0.00805900 39.4124 3606.34 0.00 5564.82 4236.81 0.35304668 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT GNW HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT GNW G NW APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 5565.769 5565.769 0.336228 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT GNW SUPPLY FAN Fan:OnOff 0.336228 0.36756263   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 Sensible 5565.77 5565.77 1.0000 0.36756263 0.336228 19.51 13.31 0.00794975 39774.6 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 5565.77 0.50 0.00431558 0.50 0.02595455 7.7193 21.10 0.00825375 21.10 0.00825375 48.1237 672.59 0.00 5573.08 5573.08 0.36106768 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT GNW_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT GNW G NW APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 5565.769 5565.769 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT GNW SUPPLY FAN Fan:OnOff 0.336228 0.36756263   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 Sensible 5565.77 5565.77 1.0000 0.36756263 0.336228 19.51 13.31 0.00794975 39774.6 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 5565.77 0.50 0.00431558 0.50 0.02595455 7.7193 21.10 0.00825375 21.10 0.00825375 48.1237 672.59 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT OFFICE HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT OFFICE OFFICE Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 6771.158 5421.363 0.409046 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.2547 1004.8586 1.0932 SPLIT OFFICE SUPPLY FAN Fan:OnOff 0.409046 0.44716636   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 12:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 12:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 09:20:00 Sensible 6127.07 6127.07 0.9049 0.44716636 0.409046 25.87 15.42 0.00775420 45759.4 12.80 10.50 0.00775420 32439.2 -999.0 -999.00 -999.00 -999.00 458.175 5668.89 34.24 0.00562096 16.49 0.03810604 9.3158 23.90 0.00797334 23.90 0.00797463 39.2393 4148.34 0.00 6770.01 5154.39 0.42950667 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT OFFICE HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT OFFICE OFFICE Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 6771.158 6771.158 0.409046 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT OFFICE SUPPLY FAN Fan:OnOff 0.409046 0.44716636   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 18:50:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 18:50:00 Sensible 6771.16 6771.16 1.0000 0.44716636 0.409046 19.18 12.82 0.00755345 38433.7 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 6771.16 0.50 0.00431558 0.50 0.03810604 9.3158 21.10 0.00788607 21.10 0.00788607 46.0077 1229.08 0.00 6780.06 6780.06 0.43926479 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT OFFICE_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT OFFICE OFFICE Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 6771.158 6771.158 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT OFFICE SUPPLY FAN Fan:OnOff 0.409046 0.44716636   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 18:50:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 18:50:00 Sensible 6771.16 6771.16 1.0000 0.44716636 0.409046 19.18 12.82 0.00755345 38433.7 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 6771.16 0.50 0.00431558 0.50 0.03810604 9.3158 21.10 0.00788607 21.10 0.00788607 46.0077 1229.08 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT GNE HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT GNE G NE APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 5171.095 4140.265 0.312386 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.4549 1004.8586 1.0932 SPLIT GNE SUPPLY FAN Fan:OnOff 0.312386 0.34149842   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 4627.35 4627.35 0.8948 0.34149842 0.312386 26.00 15.56 0.00786191 46167.8 12.80 10.60 0.00786191 32711.2 -999.0 -999.00 -999.00 -999.00 349.906 4277.44 35.61 0.00562306 16.94 0.02595455 8.3085 24.03 0.00806478 24.00 0.00806478 39.4403 3355.40 0.00 5170.22 3936.38 0.32801181 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT GNE HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT GNE G NE APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 5171.095 5171.095 0.312386 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT GNE SUPPLY FAN Fan:OnOff 0.312386 0.34149842   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 Sensible 5171.10 5171.10 1.0000 0.34149842 0.312386 19.39 13.24 0.00792588 39590.3 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 5171.10 0.50 0.00431558 0.50 0.02595455 8.3085 21.10 0.00825302 21.10 0.00825302 48.1195 674.78 0.00 5177.89 5177.89 0.33546403 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT GNE_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT GNE G NE APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 5171.095 5171.095 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT GNE SUPPLY FAN Fan:OnOff 0.312386 0.34149842   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 Sensible 5171.10 5171.10 1.0000 0.34149842 0.312386 19.39 13.24 0.00792588 39590.3 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 5171.10 0.50 0.00431558 0.50 0.02595455 8.3085 21.10 0.00825302 21.10 0.00825302 48.1195 674.78 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT GN1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT GN1 G N1 APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 4434.002 3550.107 0.267858 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.4729 1004.8586 1.0932 SPLIT GN1 SUPPLY FAN Fan:OnOff 0.267858 0.29282090   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 3974.32 3974.32 0.8963 0.29282090 0.267858 26.14 15.61 0.00787160 46339.3 12.80 10.61 0.00787160 32735.7 -999.0 -999.00 -999.00 -999.00 300.030 3674.29 35.61 0.00562306 16.94 0.02595455 9.6897 24.01 0.00811285 24.00 0.00811285 39.6727 2889.45 0.00 4433.25 3375.28 0.28125669 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT GN1 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT GN1 G N1 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 4434.002 4434.002 0.267858 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT GN1 SUPPLY FAN Fan:OnOff 0.267858 0.29282090   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 Sensible 4434.00 4434.00 1.0000 0.29282090 0.267858 19.10 13.39 0.00820571 40010.1 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4434.00 0.50 0.00431558 0.50 0.02595455 9.6897 21.10 0.00862309 21.10 0.00855208 49.8396 291.37 0.00 4439.83 4439.83 0.28764666 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT GN1_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT GN1 G N1 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 4434.002 4434.002 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT GN1 SUPPLY FAN Fan:OnOff 0.267858 0.29282090   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 Sensible 4434.00 4434.00 1.0000 0.29282090 0.267858 19.10 13.39 0.00820571 40010.1 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4434.00 0.50 0.00431558 0.50 0.02595455 9.6897 21.10 0.00862309 21.10 0.00855208 49.8396 291.37 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT GN2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT GN2 G N2 APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 4427.010 3544.509 0.267436 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.4725 1004.8586 1.0932 SPLIT GN2 SUPPLY FAN Fan:OnOff 0.267436 0.29235914   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 3968.09 3968.09 0.8963 0.29235914 0.267436 26.15 15.61 0.00787138 46340.3 12.80 10.61 0.00787138 32735.1 -999.0 -999.00 -999.00 -999.00 299.557 3668.54 35.61 0.00562306 16.94 0.02595455 9.7050 24.01 0.00811303 24.00 0.00811303 39.6735 2884.99 0.00 4426.26 3369.96 0.28081317 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT GN2 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT GN2 G N2 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 4427.010 4427.010 0.267436 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT GN2 SUPPLY FAN Fan:OnOff 0.267436 0.29235914   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 Sensible 4427.01 4427.01 1.0000 0.29235914 0.267436 19.10 13.39 0.00820495 40004.9 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4427.01 0.50 0.00431558 0.50 0.02595455 9.7050 21.10 0.00862298 21.10 0.00855199 49.8390 291.44 0.00 4432.83 4432.83 0.28719307 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT GN2_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT GN2 G N2 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 4427.010 4427.010 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT GN2 SUPPLY FAN Fan:OnOff 0.267436 0.29235914   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 Sensible 4427.01 4427.01 1.0000 0.29235914 0.267436 19.10 13.39 0.00820495 40004.9 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4427.01 0.50 0.00431558 0.50 0.02595455 9.7050 21.10 0.00862298 21.10 0.00855199 49.8390 291.44 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT GS1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT GS1 G S1 APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 4521.762 3620.372 0.273160 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7255 1004.8586 1.0932 SPLIT GS1 SUPPLY FAN Fan:OnOff 0.273160 0.29861653   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 4065.28 4060.77 0.8990 0.29861653 0.273160 26.12 15.72 0.00800750 46663.5 12.80 10.74 0.00800000 33059.8 -999.0 -999.00 -999.00 -999.00 305.968 3759.32 35.61 0.00562306 16.94 0.02595455 9.5016 24.02 0.00825784 24.00 0.00825784 40.3736 2944.64 0.00 4520.99 3442.09 0.28682344 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT GS1 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT GS1 G S1 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 4521.762 4521.762 0.273160 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT GS1 SUPPLY FAN Fan:OnOff 0.273160 0.29861653   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 Sensible 4521.76 4521.76 1.0000 0.29861653 0.273160 19.14 12.74 0.00747793 38203.2 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4521.76 0.50 0.00431558 0.50 0.02595455 9.5016 21.10 0.00780995 21.10 0.00780995 45.5692 461.92 0.00 4527.70 4527.70 0.29333989 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT GS1_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT GS1 G S1 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 4521.762 4521.762 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT GS1 SUPPLY FAN Fan:OnOff 0.273160 0.29861653   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 Sensible 4521.76 4521.76 1.0000 0.29861653 0.273160 19.14 12.74 0.00747793 38203.2 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4521.76 0.50 0.00431558 0.50 0.02595455 9.5016 21.10 0.00780995 21.10 0.00780995 45.5692 461.92 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT GS2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT GS2 G S2 APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 4617.610 3697.114 0.278950 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7244 1004.8586 1.0932 SPLIT GS2 SUPPLY FAN Fan:OnOff 0.278950 0.30494635   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 4150.63 4146.40 0.8989 0.30494635 0.278950 26.10 15.71 0.00800686 46642.6 12.80 10.74 0.00800000 33059.8 -999.0 -999.00 -999.00 -999.00 312.454 3838.17 35.61 0.00562306 16.94 0.02595455 9.3044 24.02 0.00825142 24.00 0.00825142 40.3426 3005.44 0.00 4616.82 3515.05 0.29290328 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT GS2 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT GS2 G S2 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 4617.610 4617.610 0.278950 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT GS2 SUPPLY FAN Fan:OnOff 0.278950 0.30494635   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 Sensible 4617.61 4617.61 1.0000 0.30494635 0.278950 19.18 12.77 0.00748981 38274.7 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4617.61 0.50 0.00431558 0.50 0.02595455 9.3044 21.10 0.00781545 21.10 0.00781545 45.6009 473.59 0.00 4623.68 4623.68 0.29955785 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT GS2_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT GS2 G S2 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 4617.610 4617.610 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT GS2 SUPPLY FAN Fan:OnOff 0.278950 0.30494635   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 04:00:00 Sensible 4617.61 4617.61 1.0000 0.30494635 0.278950 19.18 12.77 0.00748981 38274.7 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4617.61 0.50 0.00431558 0.50 0.02595455 9.3044 21.10 0.00781545 21.10 0.00781545 45.6009 473.59 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT MSW HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT MSW M SW APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 12886.898 10317.963 0.778498 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.5550 1004.8586 1.0932 SPLIT MSW SUPPLY FAN Fan:OnOff 0.778498 0.85104900   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 11526.87 11526.87 0.8945 0.85104900 0.778498 25.83 15.54 0.00791575 46127.2 12.80 10.66 0.00791575 32847.1 -999.0 -999.00 -999.00 -999.00 872.001 10654.87 35.61 0.00562306 16.94 0.05190911 6.6679 24.05 0.00807954 24.00 0.00807954 39.5118 16639.17 0.00 12884.71 9809.85 0.81743900 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT MSW HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT MSW M SW APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 12886.898 12886.898 0.778498 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT MSW SUPPLY FAN Fan:OnOff 0.778498 0.85104900   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 12886.90 12886.90 1.0000 0.85104900 0.778498 19.73 13.03 0.00755588 38995.6 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 12886.90 0.50 0.00431558 0.50 0.05190911 6.6679 21.10 0.00778737 21.10 0.00778737 45.4394 3639.62 0.00 12903.83 12903.83 0.83601070 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT MSW_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT MSW M SW APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 12886.898 12886.898 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT MSW SUPPLY FAN Fan:OnOff 0.778498 0.85104900   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 12886.90 12886.90 1.0000 0.85104900 0.778498 19.73 13.03 0.00755588 38995.6 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 12886.90 0.50 0.00431558 0.50 0.05190911 6.6679 21.10 0.00778737 21.10 0.00778737 45.4394 3639.62 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT MNW HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT MNW M NW APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 12709.010 10175.536 0.767751 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.4721 1004.8586 1.0932 SPLIT MNW SUPPLY FAN Fan:OnOff 0.767751 0.83930130   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 11356.68 11356.68 0.8936 0.83930130 0.767751 25.84 15.51 0.00787115 46023.9 12.80 10.61 0.00787115 32734.5 -999.0 -999.00 -999.00 -999.00 859.964 10496.72 35.61 0.00562306 16.94 0.05190911 6.7612 24.05 0.00803416 24.00 0.00803416 39.2923 16414.32 0.00 12706.85 9674.44 0.80615524 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT MNW HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT MNW M NW APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 12709.010 12709.010 0.767751 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT MNW SUPPLY FAN Fan:OnOff 0.767751 0.83930130   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 12709.01 12709.01 1.0000 0.83930130 0.767751 19.71 13.33 0.00788782 39818.6 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 12709.01 0.50 0.00431558 0.50 0.05190911 6.7612 21.10 0.00814686 21.10 0.00814686 47.5088 3060.77 0.00 12725.71 12725.71 0.82447058 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT MNW_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT MNW M NW APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 12709.010 12709.010 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT MNW SUPPLY FAN Fan:OnOff 0.767751 0.83930130   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 12709.01 12709.01 1.0000 0.83930130 0.767751 19.71 13.33 0.00788782 39818.6 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 12709.01 0.50 0.00431558 0.50 0.05190911 6.7612 21.10 0.00814686 21.10 0.00814686 47.5088 3060.77 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT MSE HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT MSE M SE APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 11834.394 9475.270 0.714916 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.5619 1004.8586 1.0932 SPLIT MSE SUPPLY FAN Fan:OnOff 0.714916 0.78154175   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 10593.09 10593.09 0.8951 0.78154175 0.714916 25.89 15.57 0.00791945 46201.9 12.80 10.66 0.00791945 32856.5 -999.0 -999.00 -999.00 -999.00 800.783 9792.30 35.61 0.00562306 16.94 0.05190911 7.2609 24.04 0.00809925 24.00 0.00809925 39.6071 15310.33 0.00 11832.38 9008.66 0.75067676 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT MSE HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT MSE M SE APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 11834.394 11834.394 0.714916 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT MSE SUPPLY FAN Fan:OnOff 0.714916 0.78154175   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 11834.39 11834.39 1.0000 0.78154175 0.714916 19.60 12.97 0.00753586 38820.3 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 11834.39 0.50 0.00431558 0.50 0.05190911 7.2609 21.10 0.00778799 21.10 0.00778799 45.4429 3650.32 0.00 11849.95 11849.95 0.76773167 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT MSE_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT MSE M SE APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 11834.394 11834.394 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT MSE SUPPLY FAN Fan:OnOff 0.714916 0.78154175   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 11834.39 11834.39 1.0000 0.78154175 0.714916 19.60 12.97 0.00753586 38820.3 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 11834.39 0.50 0.00431558 0.50 0.05190911 7.2609 21.10 0.00778799 21.10 0.00778799 45.4429 3650.32 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT MNE HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT MNE M NE APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 11658.897 9334.757 0.704314 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.4491 1004.8586 1.0932 SPLIT MNE SUPPLY FAN Fan:OnOff 0.704314 0.76995193   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 10422.01 10422.01 0.8939 0.76995193 0.704314 25.90 15.52 0.00785878 46059.6 12.80 10.60 0.00785878 32703.3 -999.0 -999.00 -999.00 -999.00 788.908 9633.10 35.61 0.00562306 16.94 0.05190911 7.3702 24.04 0.00803667 24.00 0.00803667 39.3043 15089.45 0.00 11656.91 8875.07 0.73954465 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT MNE HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT MNE M NE APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 11658.897 11658.897 0.704314 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT MNE SUPPLY FAN Fan:OnOff 0.704314 0.76995193   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 11658.90 11658.90 1.0000 0.76995193 0.704314 19.58 13.26 0.00786406 39630.5 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 11658.90 0.50 0.00431558 0.50 0.05190911 7.3702 21.10 0.00814640 21.10 0.00814640 47.5061 3071.63 0.00 11674.22 11674.22 0.75634664 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT MNE_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT MNE M NE APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 11658.897 11658.897 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT MNE SUPPLY FAN Fan:OnOff 0.704314 0.76995193   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 11658.90 11658.90 1.0000 0.76995193 0.704314 19.58 13.26 0.00786406 39630.5 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 11658.90 0.50 0.00431558 0.50 0.05190911 7.3702 21.10 0.00814640 21.10 0.00814640 47.5061 3071.63 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT MN1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT MN1 M N1 APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 9996.402 8003.672 0.603883 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.4696 1004.8586 1.0932 SPLIT MN1 SUPPLY FAN Fan:OnOff 0.603883 0.66016102   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 8949.79 8949.79 0.8953 0.66016102 0.603883 26.03 15.57 0.00786980 46220.5 12.80 10.61 0.00786980 32731.1 -999.0 -999.00 -999.00 -999.00 676.414 8273.37 35.61 0.00562306 16.94 0.05190911 8.5959 24.03 0.00808109 24.00 0.00808109 39.5191 12985.13 0.00 9994.70 7609.53 0.63408965 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT MN1 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT MN1 M N1 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 9996.402 9996.402 0.603883 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT MN1 SUPPLY FAN Fan:OnOff 0.603883 0.66016102   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 17:50:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 17:50:00 Sensible 9996.40 9996.40 1.0000 0.66016102 0.603883 19.33 13.43 0.00815312 40106.4 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 9996.40 0.50 0.00431558 0.50 0.05190911 8.5959 21.10 0.00851402 21.10 0.00800860 46.7131 754.36 0.00 10009.54 10009.54 0.64849577 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT MN1_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT MN1 M N1 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 9996.402 9996.402 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT MN1 SUPPLY FAN Fan:OnOff 0.603883 0.66016102   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 17:50:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 17:50:00 Sensible 9996.40 9996.40 1.0000 0.66016102 0.603883 19.33 13.43 0.00815312 40106.4 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 9996.40 0.50 0.00431558 0.50 0.05190911 8.5959 21.10 0.00851402 21.10 0.00800860 46.7131 754.36 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT MN2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT MN2 M N2 APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 9978.728 7989.521 0.602815 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.4691 1004.8586 1.0932 SPLIT MN2 SUPPLY FAN Fan:OnOff 0.602815 0.65899384   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 8934.04 8934.04 0.8953 0.65899384 0.602815 26.03 15.57 0.00786954 46221.4 12.80 10.61 0.00786954 32730.5 -999.0 -999.00 -999.00 -999.00 675.218 8258.82 35.61 0.00562306 16.94 0.05190911 8.6111 24.03 0.00808122 24.00 0.00808122 39.5197 12962.66 0.00 9977.03 7596.08 0.63296856 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT MN2 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT MN2 M N2 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 9978.728 9978.728 0.602815 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT MN2 SUPPLY FAN Fan:OnOff 0.602815 0.65899384   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 17:40:00 Sensible 9978.73 9978.73 1.0000 0.65899384 0.602815 19.33 13.43 0.00815240 40101.4 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 9978.73 0.50 0.00431558 0.50 0.05190911 8.6111 21.10 0.00851393 21.10 0.00843555 49.1697 1084.13 0.00 9991.84 9991.84 0.64734921 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT MN2_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT MN2 M N2 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 9978.728 9978.728 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT MN2 SUPPLY FAN Fan:OnOff 0.602815 0.65899384   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 00:10:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 17:40:00 Sensible 9978.73 9978.73 1.0000 0.65899384 0.602815 19.33 13.43 0.00815240 40101.4 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 9978.73 0.50 0.00431558 0.50 0.05190911 8.6111 21.10 0.00851393 21.10 0.00843555 49.1697 1084.13 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT MS1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT MS1 M S1 APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 10166.683 8140.008 0.614169 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.6806 1004.8586 1.0932 SPLIT MS1 SUPPLY FAN Fan:OnOff 0.614169 0.67140635   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 9125.51 9125.51 0.8976 0.67140635 0.614169 26.01 15.66 0.00798332 46492.7 12.80 10.72 0.00798332 33017.7 -999.0 -999.00 -999.00 -999.00 687.936 8437.57 35.61 0.00562306 16.94 0.05190911 8.4519 24.03 0.00820123 24.00 0.00820123 40.1000 13199.22 0.00 10164.95 7739.15 0.64489088 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT MS1 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT MS1 M S1 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 10166.683 10166.683 0.614169 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT MS1 SUPPLY FAN Fan:OnOff 0.614169 0.67140635   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 10166.68 10166.68 1.0000 0.67140635 0.614169 19.36 12.80 0.00744931 38350.8 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 10166.68 0.50 0.00431558 0.50 0.05190911 8.4519 21.10 0.00773862 21.10 0.00773862 45.1582 1921.09 0.00 10180.04 10180.04 0.65954239 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT MS1_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT MS1 M S1 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 10166.683 10166.683 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT MS1 SUPPLY FAN Fan:OnOff 0.614169 0.67140635   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 10166.68 10166.68 1.0000 0.67140635 0.614169 19.36 12.80 0.00744931 38350.8 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 10166.68 0.50 0.00431558 0.50 0.05190911 8.4519 21.10 0.00773862 21.10 0.00773862 45.1582 1921.09 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT MS2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT MS2 M S2 APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 10150.758 8127.258 0.613207 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.6806 1004.8586 1.0932 SPLIT MS2 SUPPLY FAN Fan:OnOff 0.613207 0.67035468   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 9111.34 9111.34 0.8976 0.67035468 0.613207 26.02 15.66 0.00798331 46494.1 12.80 10.72 0.00798331 33017.7 -999.0 -999.00 -999.00 -999.00 686.858 8424.48 35.61 0.00562306 16.94 0.05190911 8.4652 24.03 0.00820159 24.00 0.00820159 40.1017 13179.04 0.00 10149.03 7727.03 0.64388074 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT MS2 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT MS2 M S2 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 10150.758 10150.758 0.613207 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT MS2 SUPPLY FAN Fan:OnOff 0.613207 0.67035468   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 10150.76 10150.76 1.0000 0.67035468 0.613207 19.36 12.79 0.00744890 38347.0 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 10150.76 0.50 0.00431558 0.50 0.05190911 8.4652 21.10 0.00773867 21.10 0.00773867 45.1585 1921.38 0.00 10164.10 10164.10 0.65850931 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT MS2_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT MS2 M S2 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 10150.758 10150.758 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT MS2 SUPPLY FAN Fan:OnOff 0.613207 0.67035468   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 10150.76 10150.76 1.0000 0.67035468 0.613207 19.36 12.79 0.00744890 38347.0 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 10150.76 0.50 0.00431558 0.50 0.05190911 8.4652 21.10 0.00773867 21.10 0.00773867 45.1585 1921.38 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT TSW HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT TSW T SW APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 7447.880 5963.185 0.449926 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.5257 1004.8586 1.0932 SPLIT TSW SUPPLY FAN Fan:OnOff 0.449926 0.49185700   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 6653.29 6653.29 0.8933 0.49185700 0.449926 25.73 15.50 0.00790000 45993.7 12.80 10.64 0.00790000 32807.4 -999.0 -999.00 -999.00 -999.00 503.966 6149.32 35.61 0.00562306 16.94 0.02595455 5.7686 24.06 0.00803939 24.00 0.00803939 39.3176 4799.35 0.00 7446.61 5669.53 0.47243236 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT TSW HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT TSW T SW APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 7447.880 7447.880 0.449926 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT TSW SUPPLY FAN Fan:OnOff 0.449926 0.49185700   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 7447.88 7447.88 1.0000 0.49185700 0.449926 19.91 13.18 0.00763917 39395.6 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 7447.88 0.50 0.00431558 0.50 0.02595455 5.7686 21.10 0.00784264 21.10 0.00784264 45.7580 1628.81 0.00 7457.67 7457.67 0.48316573 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT TSW_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT TSW T SW APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 7447.880 7447.880 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT TSW SUPPLY FAN Fan:OnOff 0.449926 0.49185700   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 7447.88 7447.88 1.0000 0.49185700 0.449926 19.91 13.18 0.00763917 39395.6 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 7447.88 0.50 0.00431558 0.50 0.02595455 5.7686 21.10 0.00784264 21.10 0.00784264 45.7580 1628.81 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT TNW HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT TNW T NW APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 7430.922 5949.607 0.448902 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.4852 1004.8586 1.0932 SPLIT TNW SUPPLY FAN Fan:OnOff 0.448902 0.49073710   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 6634.74 6634.74 0.8929 0.49073710 0.448902 25.74 15.48 0.00787820 45939.6 12.80 10.62 0.00787820 32752.3 -999.0 -999.00 -999.00 -999.00 502.819 6131.92 35.61 0.00562306 16.94 0.02595455 5.7818 24.06 0.00801658 24.00 0.00801658 39.2072 4788.63 0.00 7429.66 5656.62 0.47135669 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT TNW HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT TNW T NW APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 7430.922 7430.922 0.448902 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT TNW SUPPLY FAN Fan:OnOff 0.448902 0.49073710   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 7430.92 7430.92 1.0000 0.49073710 0.448902 19.91 13.34 0.00782089 39854.4 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 7430.92 0.50 0.00431558 0.50 0.02595455 5.7818 21.10 0.00803600 21.10 0.00803600 46.8708 1473.10 0.00 7440.69 7440.69 0.48206562 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT TNW_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT TNW T NW APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 7430.922 7430.922 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT TNW SUPPLY FAN Fan:OnOff 0.448902 0.49073710   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 7430.92 7430.92 1.0000 0.49073710 0.448902 19.91 13.34 0.00782089 39854.4 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 7430.92 0.50 0.00431558 0.50 0.02595455 5.7818 21.10 0.00803600 21.10 0.00803600 46.8708 1473.10 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT TSE HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT TSE T SE APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 6673.203 5342.935 0.403128 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.5116 1004.8586 1.0932 SPLIT TSE SUPPLY FAN Fan:OnOff 0.403128 0.44069742   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 5964.40 5964.40 0.8938 0.44069742 0.403128 25.81 15.51 0.00789241 46047.3 12.80 10.63 0.00789241 32788.2 -999.0 -999.00 -999.00 -999.00 451.547 5512.86 35.61 0.00562306 16.94 0.02595455 6.4383 24.06 0.00804857 24.00 0.00804857 39.3620 4307.86 0.00 6672.07 5079.82 0.42329321 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT TSE HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT TSE T SE APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 6673.203 6673.203 0.403128 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT TSE SUPPLY FAN Fan:OnOff 0.403128 0.44069742   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 6673.20 6673.20 1.0000 0.44069742 0.403128 19.77 13.11 0.00761582 39195.8 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 6673.20 0.50 0.00431558 0.50 0.02595455 6.4383 21.10 0.00784292 21.10 0.00784292 45.7597 1631.88 0.00 6681.97 6681.97 0.43291016 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT TSE_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT TSE T SE APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 6673.203 6673.203 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT TSE SUPPLY FAN Fan:OnOff 0.403128 0.44069742   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 6673.20 6673.20 1.0000 0.44069742 0.403128 19.77 13.11 0.00761582 39195.8 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 6673.20 0.50 0.00431558 0.50 0.02595455 6.4383 21.10 0.00784292 21.10 0.00784292 45.7597 1631.88 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT TNE HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT TNE T NE APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 6655.227 5328.543 0.402042 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.4575 1004.8586 1.0932 SPLIT TNE SUPPLY FAN Fan:OnOff 0.402042 0.43951031   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 5944.26 5944.26 0.8932 0.43951031 0.402042 25.81 15.49 0.00786332 45975.0 12.80 10.60 0.00786332 32714.7 -999.0 -999.00 -999.00 -999.00 450.331 5493.93 35.61 0.00562306 16.94 0.02595455 6.4557 24.06 0.00801792 24.00 0.00801792 39.2137 4296.30 0.00 6654.09 5066.14 0.42215297 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT TNE HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT TNE T NE APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 6655.227 6655.227 0.402042 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT TNE SUPPLY FAN Fan:OnOff 0.402042 0.43951031   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 6655.23 6655.23 1.0000 0.43951031 0.402042 19.77 13.27 0.00779575 39649.1 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 6655.23 0.50 0.00431558 0.50 0.02595455 6.4557 21.10 0.00803593 21.10 0.00803593 46.8703 1476.26 0.00 6663.97 6663.97 0.43174402 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT TNE_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT TNE T NE APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 6655.227 6655.227 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT TNE SUPPLY FAN Fan:OnOff 0.402042 0.43951031   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 6655.23 6655.23 1.0000 0.43951031 0.402042 19.77 13.27 0.00779575 39649.1 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 6655.23 0.50 0.00431558 0.50 0.02595455 6.4557 21.10 0.00803593 21.10 0.00803593 46.8703 1476.26 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT TN1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT TN1 T N1 APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 5977.341 4785.789 0.361091 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.4762 1004.8586 1.0932 SPLIT TN1 SUPPLY FAN Fan:OnOff 0.361091 0.39474277   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 5344.28 5344.28 0.8941 0.39474277 0.361091 25.89 15.53 0.00787335 46081.2 12.80 10.61 0.00787335 32740.1 -999.0 -999.00 -999.00 -999.00 404.461 4939.82 35.61 0.00562306 16.94 0.02595455 7.1878 24.05 0.00804763 24.00 0.00804763 39.3573 3867.13 0.00 5976.32 4550.11 0.37915341 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT TN1 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT TN1 T N1 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 5977.341 5977.341 0.361091 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT TN1 SUPPLY FAN Fan:OnOff 0.361091 0.39474277   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 5977.34 5977.34 1.0000 0.39474277 0.361091 19.62 13.29 0.00787931 39707.5 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 5977.34 0.50 0.00431558 0.50 0.02595455 7.1878 21.10 0.00815530 21.10 0.00815530 47.5572 1003.21 0.00 5985.20 5985.20 0.38776754 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT TN1_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT TN1 T N1 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 5977.341 5977.341 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT TN1 SUPPLY FAN Fan:OnOff 0.361091 0.39474277   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 5977.34 5977.34 1.0000 0.39474277 0.361091 19.62 13.29 0.00787931 39707.5 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 5977.34 0.50 0.00431558 0.50 0.02595455 7.1878 21.10 0.00815530 21.10 0.00815530 47.5572 1003.21 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT TN2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT TN2 T N2 APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 5953.308 4766.547 0.359639 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.4752 1004.8586 1.0932 SPLIT TN2 SUPPLY FAN Fan:OnOff 0.359639 0.39315563   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 5322.89 5322.89 0.8941 0.39315563 0.359639 25.89 15.53 0.00787284 46083.1 12.80 10.61 0.00787284 32738.8 -999.0 -999.00 -999.00 -999.00 402.835 4920.06 35.61 0.00562306 16.94 0.02595455 7.2168 24.05 0.00804783 24.00 0.00804783 39.3583 3851.94 0.00 5952.29 4531.82 0.37762896 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT TN2 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT TN2 T N2 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 5953.308 5953.308 0.359639 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT TN2 SUPPLY FAN Fan:OnOff 0.359639 0.39315563   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 5953.31 5953.31 1.0000 0.39315563 0.359639 19.61 13.28 0.00787818 39698.5 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 5953.31 0.50 0.00431558 0.50 0.02595455 7.2168 21.10 0.00815529 21.10 0.00815529 47.5571 1003.31 0.00 5961.13 5961.13 0.38620845 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT TN2_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT TN2 T N2 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 5953.308 5953.308 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT TN2 SUPPLY FAN Fan:OnOff 0.359639 0.39315563   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 5953.31 5953.31 1.0000 0.39315563 0.359639 19.61 13.28 0.00787818 39698.5 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 5953.31 0.50 0.00431558 0.50 0.02595455 7.2168 21.10 0.00815529 21.10 0.00815529 47.5571 1003.31 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT TS1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT TS1 T S1 APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 6006.983 4809.522 0.362882 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.5506 1004.8586 1.0932 SPLIT TS1 SUPPLY FAN Fan:OnOff 0.362882 0.39670030   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 5375.76 5375.76 0.8949 0.39670030 0.362882 25.88 15.56 0.00791338 46179.4 12.80 10.65 0.00791338 32841.1 -999.0 -999.00 -999.00 -999.00 406.467 4969.29 35.61 0.00562306 16.94 0.02595455 7.1523 24.05 0.00808981 24.00 0.00808981 39.5614 3885.96 0.00 6005.96 4572.68 0.38103364 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT TS1 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT TS1 T S1 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 6006.983 6006.983 0.362882 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT TS1 SUPPLY FAN Fan:OnOff 0.362882 0.39670030   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 6006.98 6006.98 1.0000 0.39670030 0.362882 19.63 13.05 0.00761108 39034.0 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 6006.98 0.50 0.00431558 0.50 0.02595455 7.1523 21.10 0.00786494 21.10 0.00786494 45.8862 1159.53 0.00 6014.88 6014.88 0.38969048 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT TS1_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT TS1 T S1 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 6006.983 6006.983 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT TS1 SUPPLY FAN Fan:OnOff 0.362882 0.39670030   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 6006.98 6006.98 1.0000 0.39670030 0.362882 19.63 13.05 0.00761108 39034.0 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 6006.98 0.50 0.00431558 0.50 0.02595455 7.1523 21.10 0.00786494 21.10 0.00786494 45.8862 1159.53 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
SPLIT TS2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC SPLIT TS2 T S2 APARTMENT Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 5983.022 4790.338 0.361434 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.5503 1004.8586 1.0932 SPLIT TS2 SUPPLY FAN Fan:OnOff 0.361434 0.39511798   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 Sensible 5354.46 5354.46 0.8949 0.39511798 0.361434 25.89 15.56 0.00791325 46182.2 12.80 10.65 0.00791325 32840.8 -999.0 -999.00 -999.00 -999.00 404.846 4949.62 35.61 0.00562306 16.94 0.02595455 7.1810 24.05 0.00809043 24.00 0.00809043 39.5644 3870.81 0.00 5982.00 4554.44 0.37951380 26.67 19.44 0.01118466 55322.4 14.93 14.12 0.00970984 39560.1
SPLIT TS2 HEATING COIL COIL:HEATING:DX:SINGLESPEED AirLoop AirLoopHVAC SPLIT TS2 T S2 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 5983.022 5983.022 0.361434 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT TS2 SUPPLY FAN Fan:OnOff 0.361434 0.39511798   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 5983.02 5983.02 1.0000 0.39511798 0.361434 19.62 13.04 0.00761007 39025.4 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 5983.02 0.50 0.00431558 0.50 0.02595455 7.1810 21.10 0.00786495 21.10 0.00786495 45.8863 1159.63 0.00 5990.88 5990.88 0.38813612 21.11 15.56 0.00875166 43444.1 36.23 20.60 0.00875166 58879.1
SPLIT TS2_SUPPHEATCOIL COIL:HEATING:ELECTRIC AirLoop AirLoopHVAC SPLIT TS2 T S2 APARTMENT Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 5983.022 5983.022 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0932 SPLIT TS2 SUPPLY FAN Fan:OnOff 0.361434 0.39511798   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 unknown unknown TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB 12/21 05:00:00 Sensible 5983.02 5983.02 1.0000 0.39511798 0.361434 19.62 13.04 0.00761007 39025.4 40.00 20.06 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 5983.02 0.50 0.00431558 0.50 0.02595455 7.1810 21.10 0.00786495 21.10 0.00786495 45.8863 1159.63 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Outdoor Air Per Zone [m3/s] Outdoor Air ACH [ach] Outdoor Air Method Outdoor Air Schedule Name Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule Name
None                    


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 2218.83 1771.67 51.83
G NW APARTMENT 2494.50 4036.50 68.83
OFFICE 876.67 256.50 0.00
G NE APARTMENT 2538.33 3962.00 66.17
G N1 APARTMENT 2300.50 4223.00 67.17
G N2 APARTMENT 2302.83 4213.83 67.17
G S1 APARTMENT 2210.17 1156.17 51.17
G S2 APARTMENT 2280.17 1065.50 48.33
M SW APARTMENT 2210.17 1344.67 62.67
M NW APARTMENT 2379.67 3325.17 95.00
M SE APARTMENT 2243.50 1330.00 62.83
M NE APARTMENT 2483.83 3188.50 94.67
M N1 APARTMENT 2138.67 3423.50 84.17
M N2 APARTMENT 2144.00 3411.50 84.00
M S1 APARTMENT 2138.83 1110.33 60.33
M S2 APARTMENT 2142.67 1104.67 60.50
T SW APARTMENT 2295.00 2681.83 271.50
T NW APARTMENT 3159.00 4327.17 682.67
T SE APARTMENT 2283.33 2664.17 265.50
T NE APARTMENT 3220.83 4308.67 641.17
T N1 APARTMENT 2566.33 4490.17 461.00
T N2 APARTMENT 2578.67 4481.67 469.00
T S1 APARTMENT 2051.50 2533.83 167.00
T S2 APARTMENT 2053.17 2530.83 166.67
T CORRIDOR 8760.00 8760.00 8760.00
G CORRIDOR 6329.83 4863.17 3314.17
M CORRIDOR 8760.00 8760.00 8760.00
Facility 8760.00 8760.00 8760.00
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 0.00 17.33 0.00 0.00
G NW APARTMENT 0.00 0.00 0.00 0.00
OFFICE 0.00 14.83 0.00 0.00
G NE APARTMENT 0.00 0.00 0.00 0.00
G N1 APARTMENT 0.00 0.00 0.00 0.00
G N2 APARTMENT 0.00 0.00 0.00 0.00
G S1 APARTMENT 0.00 29.83 0.00 0.00
G S2 APARTMENT 0.00 27.67 0.00 0.00
M SW APARTMENT 0.00 12.00 0.00 0.00
M NW APARTMENT 0.00 0.00 0.00 0.00
M SE APARTMENT 0.00 16.17 0.00 0.00
M NE APARTMENT 0.00 0.00 0.00 0.00
M N1 APARTMENT 0.00 0.00 0.00 0.00
M N2 APARTMENT 0.00 0.00 0.00 0.00
M S1 APARTMENT 0.00 25.00 0.00 0.00
M S2 APARTMENT 0.00 25.33 0.00 0.00
T SW APARTMENT 0.00 16.00 0.00 0.00
T NW APARTMENT 0.00 0.00 0.00 0.00
T SE APARTMENT 0.00 18.67 0.00 0.00
T NE APARTMENT 0.00 0.00 0.00 0.00
T N1 APARTMENT 0.00 0.00 0.00 0.00
T N2 APARTMENT 0.00 0.00 0.00 0.00
T S1 APARTMENT 0.00 21.83 0.00 0.00
T S2 APARTMENT 0.00 22.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
Facility 0.00 44.67 0.00 0.00
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 2.40 2.50 268.97 0.355 0.034 0.000 0.037
G NW APARTMENT 1.71 2.50 268.97 0.355 0.036 0.000 0.056
OFFICE 4.75 4.75 268.97 0.520 0.037 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.355 0.036 0.000 0.057
G N1 APARTMENT 1.71 2.50 268.97 0.355 0.022 0.000 0.061
G N2 APARTMENT 1.71 2.50 268.97 0.355 0.022 0.000 0.061
G S1 APARTMENT 2.40 2.50 268.97 0.355 0.021 0.000 0.037
G S2 APARTMENT 2.40 2.50 268.97 0.355 0.021 0.000 0.036
M SW APARTMENT 2.40 2.50 268.97 0.355 0.050 0.000 0.041
M NW APARTMENT 1.71 2.50 268.97 0.355 0.051 0.000 0.067
M SE APARTMENT 2.40 2.50 268.97 0.355 0.050 0.000 0.040
M NE APARTMENT 1.71 2.50 268.97 0.355 0.051 0.000 0.069
M N1 APARTMENT 1.71 2.50 268.97 0.355 0.031 0.000 0.075
M N2 APARTMENT 1.71 2.50 268.97 0.355 0.031 0.000 0.075
M S1 APARTMENT 2.40 2.50 268.97 0.355 0.030 0.000 0.041
M S2 APARTMENT 2.40 2.50 268.97 0.355 0.030 0.000 0.041
T SW APARTMENT 2.40 2.50 268.97 0.355 0.065 0.000 0.051
T NW APARTMENT 1.71 2.50 268.97 0.354 0.068 0.000 0.072
T SE APARTMENT 2.40 2.50 268.97 0.355 0.065 0.000 0.051
T NE APARTMENT 1.71 2.50 268.97 0.354 0.068 0.000 0.075
T N1 APARTMENT 1.71 2.50 268.97 0.354 0.041 0.000 0.078
T N2 APARTMENT 1.71 2.50 268.97 0.354 0.041 0.000 0.078
T S1 APARTMENT 2.40 2.50 268.97 0.355 0.039 0.000 0.052
T S2 APARTMENT 2.40 2.50 268.97 0.355 0.039 0.000 0.052
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 2.40 2.50 268.97 0.348 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.97 0.346 0.000 0.000 0.000
OFFICE 4.75 4.75 268.97 0.510 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.346 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.97 0.346 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.346 0.000 0.000 0.000
G S1 APARTMENT 2.40 2.50 268.97 0.349 0.000 0.000 0.000
G S2 APARTMENT 2.40 2.50 268.97 0.349 0.000 0.000 0.000
M SW APARTMENT 2.40 2.50 268.97 0.348 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.97 0.346 0.000 0.000 0.000
M SE APARTMENT 2.40 2.50 268.97 0.348 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.97 0.346 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.97 0.347 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 0.347 0.000 0.000 0.000
M S1 APARTMENT 2.40 2.50 268.97 0.349 0.000 0.000 0.000
M S2 APARTMENT 2.40 2.50 268.97 0.349 0.000 0.000 0.000
T SW APARTMENT 2.40 2.50 268.97 0.346 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.97 0.346 0.000 0.000 0.000
T SE APARTMENT 2.40 2.50 268.97 0.346 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.97 0.346 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.97 0.346 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.346 0.000 0.000 0.000
T S1 APARTMENT 2.40 2.50 268.97 0.346 0.000 0.000 0.000
T S2 APARTMENT 2.40 2.50 268.97 0.346 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Outdoor Air Details

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Mechanical Ventilation Parameters by Zone

AirLoop Name Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Zone Area [m2] Design Zone Outdoor Airflow - Voz [m3/s] Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s]
G SW APARTMENT SPLIT GSW 2.40 2.50 268.97 88.25 0.0260 0.026
G NW APARTMENT SPLIT GNW 1.71 2.50 268.97 88.25 0.0260 0.026
OFFICE SPLIT OFFICE 4.75 4.75 268.97 88.25 0.0381 0.038
G NE APARTMENT SPLIT GNE 1.71 2.50 268.97 88.25 0.0260 0.026
G N1 APARTMENT SPLIT GN1 1.71 2.50 268.97 88.25 0.0260 0.026
G N2 APARTMENT SPLIT GN2 1.71 2.50 268.97 88.25 0.0260 0.026
G S1 APARTMENT SPLIT GS1 2.40 2.50 268.97 88.25 0.0260 0.026
G S2 APARTMENT SPLIT GS2 2.40 2.50 268.97 88.25 0.0260 0.026
M SW APARTMENT SPLIT MSW 2.40 2.50 268.97 88.25 0.0519 0.052
M NW APARTMENT SPLIT MNW 1.71 2.50 268.97 88.25 0.0519 0.052
M SE APARTMENT SPLIT MSE 2.40 2.50 268.97 88.25 0.0519 0.052
M NE APARTMENT SPLIT MNE 1.71 2.50 268.97 88.25 0.0519 0.052
M N1 APARTMENT SPLIT MN1 1.71 2.50 268.97 88.25 0.0519 0.052
M N2 APARTMENT SPLIT MN2 1.71 2.50 268.97 88.25 0.0519 0.052
M S1 APARTMENT SPLIT MS1 2.40 2.50 268.97 88.25 0.0519 0.052
M S2 APARTMENT SPLIT MS2 2.40 2.50 268.97 88.25 0.0519 0.052
T SW APARTMENT SPLIT TSW 2.40 2.50 268.97 88.25 0.0260 0.026
T NW APARTMENT SPLIT TNW 1.71 2.50 268.97 88.25 0.0260 0.026
T SE APARTMENT SPLIT TSE 2.40 2.50 268.97 88.25 0.0260 0.026
T NE APARTMENT SPLIT TNE 1.71 2.50 268.97 88.25 0.0260 0.026
T N1 APARTMENT SPLIT TN1 1.71 2.50 268.97 88.25 0.0260 0.026
T N2 APARTMENT SPLIT TN2 1.71 2.50 268.97 88.25 0.0260 0.026
T S1 APARTMENT SPLIT TS1 2.40 2.50 268.97 88.25 0.0260 0.026
T S2 APARTMENT SPLIT TS2 2.40 2.50 268.97 88.25 0.0260 0.026
Total Facility   68.19 82.25 8607.06 2823.98 0.8427 1.258


Total Outdoor Air by Zone

Mechanical Ventilation [m3] Natural Ventilation [m3] Total Ventilation [m3] Infiltration [m3] Total Ventilation and Infiltration [m3] Dynamic Target Ventilation - Voz-dyn [m3] Time Below Voz-dyn [hr] Time At Voz-dyn [hr] Time Above Voz-dyn [hr] Time Above Zero When Unoccupied [hr]
G SW APARTMENT 818502.78 100928.49 919431.27 82267.25 1001698.52 818502.78 0.00 7747.31 1012.69 2615.00
G NW APARTMENT 818502.78 130162.12 948664.89 82267.25 1030932.14 818502.78 0.00 7307.11 1452.89 0.00
OFFICE 1162556.92 0.00 1162556.92 82267.25 1244824.17 1201711.97 500.00 8260.00 0.00 7010.00
G NE APARTMENT 818502.78 132230.38 950733.16 82267.25 1033000.41 818502.78 0.00 7315.92 1444.08 0.00
G N1 APARTMENT 818502.78 140045.83 958548.61 49621.52 1008170.13 818502.78 0.00 7225.58 1534.42 0.00
G N2 APARTMENT 818502.78 139819.92 958322.70 49621.52 1007944.22 818502.78 0.00 7228.16 1531.84 0.00
G S1 APARTMENT 818502.78 94626.77 913129.55 49621.52 962751.06 818502.78 0.00 7822.26 937.74 2615.00
G S2 APARTMENT 818502.78 91718.43 910221.21 49621.52 959842.72 818502.78 0.00 7857.25 902.75 2615.00
M SW APARTMENT 1637005.55 105975.33 1742980.88 118224.12 1861205.00 1637005.55 0.00 7828.72 931.28 2615.00
M NW APARTMENT 1637005.55 154434.68 1791440.23 118224.12 1909664.35 1637005.55 0.00 7256.25 1503.75 0.00
M SE APARTMENT 1637005.55 93152.07 1730157.63 118224.12 1848381.74 1637005.55 0.00 7955.44 804.56 2615.00
M NE APARTMENT 1637005.55 158857.15 1795862.71 118224.12 1914086.82 1637005.55 0.00 7240.77 1519.23 0.00
M N1 APARTMENT 1637005.55 171976.01 1808981.57 71309.79 1880291.36 1637005.55 0.00 7111.24 1648.76 0.00
M N2 APARTMENT 1637005.55 171977.61 1808983.17 71309.79 1880292.96 1637005.55 0.00 7112.07 1647.93 0.00
M S1 APARTMENT 1637005.55 100095.32 1737100.88 71309.79 1808410.67 1637005.55 0.00 7884.74 875.26 2615.00
M S2 APARTMENT 1637005.55 99579.02 1736584.58 71309.79 1807894.36 1637005.55 0.00 7889.52 870.48 2615.00
T SW APARTMENT 818502.78 138326.06 956828.83 156385.55 1113214.38 818502.78 0.00 7647.90 1112.10 2615.00
T NW APARTMENT 818502.78 167243.39 985746.17 156385.55 1142131.71 818502.78 0.00 7243.09 1516.91 0.00
T SE APARTMENT 818502.78 129710.69 948213.46 156385.55 1104599.01 818502.78 0.00 7745.81 1014.19 2615.00
T NE APARTMENT 818502.78 172995.71 991498.49 156385.55 1147884.03 818502.78 0.00 7214.10 1545.90 0.00
T N1 APARTMENT 818502.78 179541.44 998044.21 94327.79 1092372.01 818502.78 0.00 7146.71 1613.29 0.00
T N2 APARTMENT 818502.78 179390.77 997893.55 94327.79 1092221.34 818502.78 0.00 7145.72 1614.28 0.00
T S1 APARTMENT 818502.78 136259.76 954762.54 94327.79 1049090.33 818502.78 0.00 7685.93 1074.07 2615.00
T S2 APARTMENT 818502.78 135344.17 953846.95 94327.79 1048174.74 818502.78 0.00 7693.98 1066.02 2615.00
Total Facility 39632187.45 4180438.34 43812625.79 3046679.66 46859305.45 39671342.50 500.00 8736.67 1671.86 8760.00


Average Outdoor Air During Occupancy by Zone - Flow Rates

Mechanical Ventilation [m3/s] Natural Ventilation [m3/s] Total Ventilation [m3/s] Infiltration [m3/s] Total Ventilation and Infiltration [m3/s] Dynamic Target Ventilation - Voz-dyn [m3/s] Time Below Voz-dyn [hr] Time At Voz-dyn [hr] Time Above Voz-dyn [hr]
G SW APARTMENT 0.0260 0.0027 0.0287 0.0025 0.0312 0.0260 0.00 5534.02 610.98
G NW APARTMENT 0.0260 0.0041 0.0301 0.0026 0.0327 0.0260 0.00 7307.11 1452.89
OFFICE 0.0381 0.0000 0.0381 0.0027 0.0408 0.0381 0.00 1750.00 0.00
G NE APARTMENT 0.0260 0.0042 0.0301 0.0026 0.0328 0.0260 0.00 7315.92 1444.08
G N1 APARTMENT 0.0260 0.0044 0.0304 0.0016 0.0320 0.0260 0.00 7225.58 1534.42
G N2 APARTMENT 0.0260 0.0044 0.0304 0.0016 0.0320 0.0260 0.00 7228.16 1531.84
G S1 APARTMENT 0.0260 0.0027 0.0287 0.0015 0.0302 0.0260 0.00 5546.06 598.94
G S2 APARTMENT 0.0260 0.0026 0.0286 0.0015 0.0301 0.0260 0.00 5573.59 571.41
M SW APARTMENT 0.0519 0.0030 0.0549 0.0036 0.0585 0.0519 0.00 5541.06 603.94
M NW APARTMENT 0.0519 0.0049 0.0568 0.0037 0.0606 0.0519 0.00 7256.25 1503.75
M SE APARTMENT 0.0519 0.0029 0.0548 0.0036 0.0584 0.0519 0.00 5572.87 572.13
M NE APARTMENT 0.0519 0.0050 0.0569 0.0037 0.0607 0.0519 0.00 7240.77 1519.23
M N1 APARTMENT 0.0519 0.0055 0.0574 0.0023 0.0596 0.0519 0.00 7111.24 1648.76
M N2 APARTMENT 0.0519 0.0055 0.0574 0.0023 0.0596 0.0519 0.00 7112.07 1647.93
M S1 APARTMENT 0.0519 0.0030 0.0549 0.0022 0.0571 0.0519 0.00 5550.74 594.26
M S2 APARTMENT 0.0519 0.0030 0.0549 0.0022 0.0571 0.0519 0.00 5553.54 591.46
T SW APARTMENT 0.0260 0.0037 0.0297 0.0048 0.0344 0.0260 0.00 5473.20 671.80
T NW APARTMENT 0.0260 0.0053 0.0313 0.0050 0.0362 0.0260 0.00 7243.09 1516.91
T SE APARTMENT 0.0260 0.0037 0.0297 0.0048 0.0345 0.0260 0.00 5481.37 663.63
T NE APARTMENT 0.0260 0.0055 0.0314 0.0050 0.0364 0.0260 0.00 7214.10 1545.90
T N1 APARTMENT 0.0260 0.0057 0.0316 0.0030 0.0346 0.0260 0.00 7146.71 1613.29
T N2 APARTMENT 0.0260 0.0057 0.0316 0.0030 0.0346 0.0260 0.00 7145.72 1614.28
T S1 APARTMENT 0.0260 0.0038 0.0297 0.0029 0.0326 0.0260 0.00 5469.18 675.82
T S2 APARTMENT 0.0260 0.0038 0.0297 0.0029 0.0326 0.0260 0.00 5471.57 673.43
Total Facility 1.2580 0.1278 1.3858 0.0951 1.4809 1.2580 500.00 8736.67 1671.86


Total Outdoor Air by AirLoop

Mechanical Ventilation [m3] Natural Ventilation [m3/s] Total Ventilation [m3/s] Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] Time Below Voz-sum-dyn [hr] Time At Voz-sum-dyn [hr] Time Above Voz-sum-dyn [hr] Time Above Zero When Unoccupied [hr]
SPLIT GSW 0.00 100928.49 100928.49 818502.78 8096.52 29.80 633.68 401.71
SPLIT GNW 0.00 130162.12 130162.12 818502.78 8088.25 54.34 617.41 0.00
SPLIT OFFICE 1389341.07 0.00 1389341.07 1201711.97 500.00 0.00 8260.00 7010.00
SPLIT GNE 0.00 132230.38 132230.38 818502.78 8040.64 52.32 667.04 0.00
SPLIT GN1 0.00 140045.83 140045.83 818502.78 8011.50 47.86 700.64 0.00
SPLIT GN2 0.00 139819.92 139819.92 818502.78 8011.05 48.23 700.73 0.00
SPLIT GS1 0.00 94626.77 94626.77 818502.78 8129.57 23.99 606.44 338.80
SPLIT GS2 0.00 91718.43 91718.43 818502.78 8140.70 22.27 597.03 331.33
SPLIT MSW 0.00 105975.33 105975.33 1637005.55 8737.78 4.39 17.83 327.34
SPLIT MNW 0.00 154434.68 154434.68 1637005.55 8731.92 3.06 25.02 0.00
SPLIT MSE 0.00 93152.07 93152.07 1637005.55 8736.97 4.48 18.55 232.42
SPLIT MNE 0.00 158857.15 158857.15 1637005.55 8732.74 2.79 24.47 0.00
SPLIT MN1 0.00 171976.01 171976.01 1637005.55 8727.93 3.99 28.08 0.00
SPLIT MN2 0.00 171977.61 171977.61 1637005.55 8727.93 3.99 28.08 0.00
SPLIT MS1 0.00 100095.32 100095.32 1637005.55 8736.03 4.26 19.72 281.00
SPLIT MS2 0.00 99579.02 99579.02 1637005.55 8736.08 4.26 19.66 279.02
SPLIT TSW 0.00 138326.06 138326.06 818502.78 7829.45 17.32 913.23 440.30
SPLIT TNW 0.00 167243.39 167243.39 818502.78 7756.11 37.21 966.68 0.00
SPLIT TSE 0.00 129710.69 129710.69 818502.78 7876.62 13.63 869.75 350.56
SPLIT TNE 0.00 172995.71 172995.71 818502.78 7657.15 44.13 1058.72 0.00
SPLIT TN1 0.00 179541.44 179541.44 818502.78 7659.32 45.33 1055.34 0.00
SPLIT TN2 0.00 179390.77 179390.77 818502.78 7655.02 43.39 1061.58 0.00
SPLIT TS1 0.00 136259.76 136259.76 818502.78 7837.78 16.29 905.93 398.25
SPLIT TS2 0.00 135344.17 135344.17 818502.78 7843.29 16.11 900.60 392.58


Average Outdoor Air During Occupancy by AirLoop

Mechanical Ventilation [m3/s] Natural Ventilation [m3/s] Total Ventilation [m3/s] Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] Time Below Voz-sum-dyn [hr] Time At Voz-sum-dyn [hr] Time Above Voz-sum-dyn [hr]
SPLIT GSW 0.0000 0.0027 0.0027 0.0260 5746.33 15.52 383.15
SPLIT GNW 0.0000 0.0041 0.0041 0.0260 8088.25 54.34 617.41
SPLIT OFFICE 0.0455 0.0000 0.0455 0.0381 0.00 0.00 1750.00
SPLIT GNE 0.0000 0.0042 0.0042 0.0260 8040.64 52.32 667.04
SPLIT GN1 0.0000 0.0044 0.0044 0.0260 8011.50 47.86 700.64
SPLIT GN2 0.0000 0.0044 0.0044 0.0260 8011.05 48.23 700.73
SPLIT GS1 0.0000 0.0027 0.0027 0.0260 5749.22 13.22 382.56
SPLIT GS2 0.0000 0.0026 0.0026 0.0260 5756.37 11.97 376.67
SPLIT MSW 0.0000 0.0030 0.0030 0.0519 6137.61 1.52 5.87
SPLIT MNW 0.0000 0.0049 0.0049 0.0519 8731.92 3.06 25.02
SPLIT MSE 0.0000 0.0029 0.0029 0.0519 6136.18 1.77 7.05
SPLIT MNE 0.0000 0.0050 0.0050 0.0519 8732.74 2.79 24.47
SPLIT MN1 0.0000 0.0055 0.0055 0.0519 8727.93 3.99 28.08
SPLIT MN2 0.0000 0.0055 0.0055 0.0519 8727.93 3.99 28.08
SPLIT MS1 0.0000 0.0030 0.0030 0.0519 6135.62 1.67 7.71
SPLIT MS2 0.0000 0.0030 0.0030 0.0519 6135.67 1.67 7.65
SPLIT TSW 0.0000 0.0037 0.0037 0.0260 5583.02 10.91 551.06
SPLIT TNW 0.0000 0.0053 0.0053 0.0260 7756.11 37.21 966.68
SPLIT TSE 0.0000 0.0037 0.0037 0.0260 5566.51 9.98 568.51
SPLIT TNE 0.0000 0.0055 0.0055 0.0260 7657.15 44.13 1058.72
SPLIT TN1 0.0000 0.0057 0.0057 0.0260 7659.32 45.33 1055.34
SPLIT TN2 0.0000 0.0057 0.0057 0.0260 7655.02 43.39 1061.58
SPLIT TS1 0.0000 0.0038 0.0038 0.0260 5566.24 11.39 567.37
SPLIT TS2 0.0000 0.0038 0.0038 0.0260 5567.58 11.33 566.09


Outdoor Air Controller Limiting Factors by AirLoop

No Limiting Factor [hr] Limits and Scheduled Limits [hr] Economizer [hr] Exhaust Flow [hr] Mixed Air Flow [hr] High Humidity [hr] Demand Controlled Ventilation [hr] Night Ventilation [hr] Demand Limiting [hr] Energy Management System [hr]
SPLIT GSW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT GNW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT OFFICE 500.00 8260.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT GNE 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT GN1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT GN2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT GS1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT GS2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT MSW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT MNW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT MSE 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT MNE 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT MN1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT MN2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT MS1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT MS2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT TSW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT TNW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT TSE 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT TNE 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT TN1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT TN2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT TS1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
SPLIT TS2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Average Outdoor Air for Limiting Factors During Occupancy

No Limiting Factor [m3/s] Limits and Scheduled Limits [m3/s] Economizer [m3/s] Exhaust Flow [m3/s] Mixed Air Flow [m3/s] High Humidity [m3/s] Demand Controlled Ventilation [m3/s] Night Ventilation [m3/s] Demand Limiting [m3/s] Energy Management System [m3/s]
SPLIT GSW 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT GNW 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT OFFICE 0.0000 0.0455 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT GNE 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT GN1 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT GN2 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT GS1 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT GS2 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT MSW 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT MNW 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT MSE 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT MNE 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT MN1 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT MN2 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT MS1 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT MS2 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT TSW 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT TNW 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT TSE 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT TNE 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT TN1 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT TN2 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT TS1 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
SPLIT TS2 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000



Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Surfaces by Class

Total Outdoors
Wall 126 42
Floor 27 9
Roof 27 9
Internal Mass 24 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 39 39
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 24
Conditioned Zones 24
Unconditioned Zones 3
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 1593
Defaulted Fields 1670
Fields with Defaults 5812
Autosized Fields 648
Autosizable Fields 770
Autocalculated Fields 332
Autocalculatable Fields 509



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Electricity Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
Electricity:Facility 836.23 12620.56 12-FEB-03:20 65237.17 28-JUN-16:20
Electricity:Building 477.47 9122.17 01-JAN-03:10 22826.83 03-JAN-17:10
Electricity:Zone:G SW APARTMENT 12.68 226.48 01-JAN-03:10 626.50 01-JAN-18:10
Electricity:SpaceType:GENERAL 477.47 9122.17 01-JAN-03:10 22826.83 03-JAN-17:10
InteriorLights:Electricity 53.86 1256.88 01-JAN-00:10 2561.45 01-JAN-19:10
InteriorLights:Electricity:Zone:G SW APARTMENT 0.47 2.81 01-JAN-00:10 44.89 01-JAN-19:10
InteriorLights:Electricity:SpaceType:GENERAL 53.86 1256.88 01-JAN-00:10 2561.45 01-JAN-19:10
LightsWired:InteriorLights:Electricity 49.34 1229.88 01-JAN-00:10 2129.58 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:G SW APARTMENT 0.32 1.94 01-JAN-00:10 30.96 01-JAN-19:10
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL 49.34 1229.88 01-JAN-00:10 2129.58 01-JAN-19:10
Electricity:Zone:G NW APARTMENT 12.68 226.48 01-JAN-03:10 626.50 01-JAN-18:10
InteriorLights:Electricity:Zone:G NW APARTMENT 0.47 2.81 01-JAN-00:10 44.89 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:G NW APARTMENT 0.32 1.94 01-JAN-00:10 30.96 01-JAN-19:10
Electricity:Zone:OFFICE 12.29 203.89 01-JAN-00:10 920.93 03-JAN-08:10
InteriorLights:Electricity:Zone:OFFICE 4.77 75.20 01-JAN-00:10 376.01 03-JAN-08:10
LightsWired:InteriorLights:Electricity:Zone:OFFICE 4.77 75.20 01-JAN-00:10 376.01 03-JAN-08:10
Electricity:Zone:G NE APARTMENT 12.68 226.48 01-JAN-03:10 626.50 01-JAN-18:10
InteriorLights:Electricity:Zone:G NE APARTMENT 0.47 2.81 01-JAN-00:10 44.89 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:G NE APARTMENT 0.32 1.94 01-JAN-00:10 30.96 01-JAN-19:10
Electricity:Zone:G N1 APARTMENT 12.68 226.48 01-JAN-03:10 626.50 01-JAN-18:10
InteriorLights:Electricity:Zone:G N1 APARTMENT 0.47 2.81 01-JAN-00:10 44.89 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:G N1 APARTMENT 0.32 1.94 01-JAN-00:10 30.96 01-JAN-19:10
Electricity:Zone:G N2 APARTMENT 12.68 226.48 01-JAN-03:10 626.50 01-JAN-18:10
InteriorLights:Electricity:Zone:G N2 APARTMENT 0.47 2.81 01-JAN-00:10 44.89 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:G N2 APARTMENT 0.32 1.94 01-JAN-00:10 30.96 01-JAN-19:10
Electricity:Zone:G S1 APARTMENT 12.68 226.48 01-JAN-03:10 626.50 01-JAN-18:10
InteriorLights:Electricity:Zone:G S1 APARTMENT 0.47 2.81 01-JAN-00:10 44.89 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:G S1 APARTMENT 0.32 1.94 01-JAN-00:10 30.96 01-JAN-19:10
Electricity:Zone:G S2 APARTMENT 12.68 226.48 01-JAN-03:10 626.50 01-JAN-18:10
InteriorLights:Electricity:Zone:G S2 APARTMENT 0.47 2.81 01-JAN-00:10 44.89 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:G S2 APARTMENT 0.32 1.94 01-JAN-00:10 30.96 01-JAN-19:10
Electricity:Zone:M SW APARTMENT 25.37 452.97 01-JAN-03:10 1253.00 01-JAN-18:10
InteriorLights:Electricity:Zone:M SW APARTMENT 0.94 5.61 01-JAN-00:10 89.78 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:M SW APARTMENT 0.65 3.87 01-JAN-00:10 61.92 01-JAN-19:10
Electricity:Zone:M NW APARTMENT 25.37 452.97 01-JAN-03:10 1253.00 01-JAN-18:10
InteriorLights:Electricity:Zone:M NW APARTMENT 0.94 5.61 01-JAN-00:10 89.78 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:M NW APARTMENT 0.65 3.87 01-JAN-00:10 61.92 01-JAN-19:10
Electricity:Zone:M SE APARTMENT 25.37 452.97 01-JAN-03:10 1253.00 01-JAN-18:10
InteriorLights:Electricity:Zone:M SE APARTMENT 0.94 5.61 01-JAN-00:10 89.78 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:M SE APARTMENT 0.65 3.87 01-JAN-00:10 61.92 01-JAN-19:10
Electricity:Zone:M NE APARTMENT 25.37 452.97 01-JAN-03:10 1253.00 01-JAN-18:10
InteriorLights:Electricity:Zone:M NE APARTMENT 0.94 5.61 01-JAN-00:10 89.78 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:M NE APARTMENT 0.65 3.87 01-JAN-00:10 61.92 01-JAN-19:10
Electricity:Zone:M N1 APARTMENT 25.37 452.97 01-JAN-03:10 1253.00 01-JAN-18:10
InteriorLights:Electricity:Zone:M N1 APARTMENT 0.94 5.61 01-JAN-00:10 89.78 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:M N1 APARTMENT 0.65 3.87 01-JAN-00:10 61.92 01-JAN-19:10
Electricity:Zone:M N2 APARTMENT 25.37 452.97 01-JAN-03:10 1253.00 01-JAN-18:10
InteriorLights:Electricity:Zone:M N2 APARTMENT 0.94 5.61 01-JAN-00:10 89.78 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:M N2 APARTMENT 0.65 3.87 01-JAN-00:10 61.92 01-JAN-19:10
Electricity:Zone:M S1 APARTMENT 25.37 452.97 01-JAN-03:10 1253.00 01-JAN-18:10
InteriorLights:Electricity:Zone:M S1 APARTMENT 0.94 5.61 01-JAN-00:10 89.78 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:M S1 APARTMENT 0.65 3.87 01-JAN-00:10 61.92 01-JAN-19:10
Electricity:Zone:M S2 APARTMENT 25.37 452.97 01-JAN-03:10 1253.00 01-JAN-18:10
InteriorLights:Electricity:Zone:M S2 APARTMENT 0.94 5.61 01-JAN-00:10 89.78 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:M S2 APARTMENT 0.65 3.87 01-JAN-00:10 61.92 01-JAN-19:10
Electricity:Zone:T SW APARTMENT 12.68 226.48 01-JAN-03:10 626.50 01-JAN-18:10
InteriorLights:Electricity:Zone:T SW APARTMENT 0.47 2.81 01-JAN-00:10 44.89 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:T SW APARTMENT 0.32 1.94 01-JAN-00:10 30.96 01-JAN-19:10
Electricity:Zone:T NW APARTMENT 12.68 226.48 01-JAN-03:10 626.50 01-JAN-18:10
InteriorLights:Electricity:Zone:T NW APARTMENT 0.47 2.81 01-JAN-00:10 44.89 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:T NW APARTMENT 0.32 1.94 01-JAN-00:10 30.96 01-JAN-19:10
Electricity:Zone:T SE APARTMENT 12.68 226.48 01-JAN-03:10 626.50 01-JAN-18:10
InteriorLights:Electricity:Zone:T SE APARTMENT 0.47 2.81 01-JAN-00:10 44.89 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:T SE APARTMENT 0.32 1.94 01-JAN-00:10 30.96 01-JAN-19:10
Electricity:Zone:T NE APARTMENT 12.68 226.48 01-JAN-03:10 626.50 01-JAN-18:10
InteriorLights:Electricity:Zone:T NE APARTMENT 0.47 2.81 01-JAN-00:10 44.89 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:T NE APARTMENT 0.32 1.94 01-JAN-00:10 30.96 01-JAN-19:10
Electricity:Zone:T N1 APARTMENT 12.68 226.48 01-JAN-03:10 626.50 01-JAN-18:10
InteriorLights:Electricity:Zone:T N1 APARTMENT 0.47 2.81 01-JAN-00:10 44.89 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:T N1 APARTMENT 0.32 1.94 01-JAN-00:10 30.96 01-JAN-19:10
Electricity:Zone:T N2 APARTMENT 12.68 226.48 01-JAN-03:10 626.50 01-JAN-18:10
InteriorLights:Electricity:Zone:T N2 APARTMENT 0.47 2.81 01-JAN-00:10 44.89 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:T N2 APARTMENT 0.32 1.94 01-JAN-00:10 30.96 01-JAN-19:10
Electricity:Zone:T S1 APARTMENT 12.68 226.48 01-JAN-03:10 626.50 01-JAN-18:10
InteriorLights:Electricity:Zone:T S1 APARTMENT 0.47 2.81 01-JAN-00:10 44.89 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:T S1 APARTMENT 0.32 1.94 01-JAN-00:10 30.96 01-JAN-19:10
Electricity:Zone:T S2 APARTMENT 12.68 226.48 01-JAN-03:10 626.50 01-JAN-18:10
InteriorLights:Electricity:Zone:T S2 APARTMENT 0.47 2.81 01-JAN-00:10 44.89 01-JAN-19:10
LightsWired:InteriorLights:Electricity:Zone:T S2 APARTMENT 0.32 1.94 01-JAN-00:10 30.96 01-JAN-19:10
Electricity:Zone:G CORRIDOR 46.12 1076.30 01-JAN-00:10 2618.62 01-JAN-07:10
InteriorLights:Electricity:Zone:G CORRIDOR 8.63 273.67 01-JAN-00:10 273.67 01-JAN-00:10
LightsWired:InteriorLights:Electricity:Zone:G CORRIDOR 8.63 273.67 01-JAN-00:10 273.67 01-JAN-00:10
Electricity:Zone:M CORRIDOR 17.26 547.34 01-JAN-00:10 547.34 01-JAN-00:10
InteriorLights:Electricity:Zone:M CORRIDOR 17.26 547.34 01-JAN-00:10 547.34 01-JAN-00:10
LightsWired:InteriorLights:Electricity:Zone:M CORRIDOR 17.26 547.34 01-JAN-00:10 547.34 01-JAN-00:10
Electricity:Zone:T CORRIDOR 8.63 273.67 01-JAN-00:10 273.67 01-JAN-00:10
InteriorLights:Electricity:Zone:T CORRIDOR 8.63 273.67 01-JAN-00:10 273.67 01-JAN-00:10
LightsWired:InteriorLights:Electricity:Zone:T CORRIDOR 8.63 273.67 01-JAN-00:10 273.67 01-JAN-00:10
LightsPlugIn:InteriorLights:Electricity 4.52 27.00 01-JAN-00:10 431.87 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:G SW APARTMENT 0.15 0.87 01-JAN-00:10 13.93 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:SpaceType:GENERAL 4.52 27.00 01-JAN-00:10 431.87 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:G NW APARTMENT 0.15 0.87 01-JAN-00:10 13.93 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:G NE APARTMENT 0.15 0.87 01-JAN-00:10 13.93 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:G N1 APARTMENT 0.15 0.87 01-JAN-00:10 13.93 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:G N2 APARTMENT 0.15 0.87 01-JAN-00:10 13.93 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:G S1 APARTMENT 0.15 0.87 01-JAN-00:10 13.93 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:G S2 APARTMENT 0.15 0.87 01-JAN-00:10 13.93 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:M SW APARTMENT 0.29 1.74 01-JAN-00:10 27.86 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:M NW APARTMENT 0.29 1.74 01-JAN-00:10 27.86 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:M SE APARTMENT 0.29 1.74 01-JAN-00:10 27.86 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:M NE APARTMENT 0.29 1.74 01-JAN-00:10 27.86 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:M N1 APARTMENT 0.29 1.74 01-JAN-00:10 27.86 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:M N2 APARTMENT 0.29 1.74 01-JAN-00:10 27.86 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:M S1 APARTMENT 0.29 1.74 01-JAN-00:10 27.86 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:M S2 APARTMENT 0.29 1.74 01-JAN-00:10 27.86 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:T SW APARTMENT 0.15 0.87 01-JAN-00:10 13.93 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:T NW APARTMENT 0.15 0.87 01-JAN-00:10 13.93 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:T SE APARTMENT 0.15 0.87 01-JAN-00:10 13.93 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:T NE APARTMENT 0.15 0.87 01-JAN-00:10 13.93 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:T N1 APARTMENT 0.15 0.87 01-JAN-00:10 13.93 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:T N2 APARTMENT 0.15 0.87 01-JAN-00:10 13.93 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:T S1 APARTMENT 0.15 0.87 01-JAN-00:10 13.93 01-JAN-19:10
LightsPlugIn:InteriorLights:Electricity:Zone:T S2 APARTMENT 0.15 0.87 01-JAN-00:10 13.93 01-JAN-19:10
InteriorEquipment:Electricity 423.60 7865.30 01-JAN-03:10 20787.24 03-JAN-17:10
InteriorEquipment:Electricity:Zone:G CORRIDOR 37.49 802.63 01-JAN-00:10 2344.96 01-JAN-07:10
InteriorEquipment:Electricity:SpaceType:GENERAL 423.60 7865.30 01-JAN-03:10 20787.24 03-JAN-17:10
ElevatorLift:InteriorEquipment:Electricity 37.08 800.00 01-JAN-00:10 2318.63 01-JAN-07:10
ElevatorLift:InteriorEquipment:Electricity:Zone:G CORRIDOR 37.08 800.00 01-JAN-00:10 2318.63 01-JAN-07:10
ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL 37.08 800.00 01-JAN-00:10 2318.63 01-JAN-07:10
ElevatorLightsFan:InteriorEquipment:Electricity 0.41 2.63 01-JAN-00:10 26.33 01-JAN-07:10
ElevatorLightsFan:InteriorEquipment:Electricity:Zone:G CORRIDOR 0.41 2.63 01-JAN-00:10 26.33 01-JAN-07:10
ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL 0.41 2.63 01-JAN-00:10 26.33 01-JAN-07:10
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity 386.12 7062.66 01-JAN-03:10 18442.28 03-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL 386.12 7062.66 01-JAN-03:10 18442.28 03-JAN-17:10
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
InteriorEquipment:Electricity:Zone:OFFICE 7.52 128.69 01-JAN-00:10 544.92 03-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:OFFICE 7.52 128.69 01-JAN-00:10 544.92 03-JAN-08:10
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
InteriorEquipment:Electricity:Zone:M SW APARTMENT 24.43 447.35 01-JAN-03:10 1177.25 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:M SW APARTMENT 24.43 447.35 01-JAN-03:10 1177.25 01-JAN-17:10
InteriorEquipment:Electricity:Zone:M NW APARTMENT 24.43 447.35 01-JAN-03:10 1177.25 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:M NW APARTMENT 24.43 447.35 01-JAN-03:10 1177.25 01-JAN-17:10
InteriorEquipment:Electricity:Zone:M SE APARTMENT 24.43 447.35 01-JAN-03:10 1177.25 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:M SE APARTMENT 24.43 447.35 01-JAN-03:10 1177.25 01-JAN-17:10
InteriorEquipment:Electricity:Zone:M NE APARTMENT 24.43 447.35 01-JAN-03:10 1177.25 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:M NE APARTMENT 24.43 447.35 01-JAN-03:10 1177.25 01-JAN-17:10
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 24.43 447.35 01-JAN-03:10 1177.25 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:M N1 APARTMENT 24.43 447.35 01-JAN-03:10 1177.25 01-JAN-17:10
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 24.43 447.35 01-JAN-03:10 1177.25 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:M N2 APARTMENT 24.43 447.35 01-JAN-03:10 1177.25 01-JAN-17:10
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 24.43 447.35 01-JAN-03:10 1177.25 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:M S1 APARTMENT 24.43 447.35 01-JAN-03:10 1177.25 01-JAN-17:10
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 24.43 447.35 01-JAN-03:10 1177.25 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:M S2 APARTMENT 24.43 447.35 01-JAN-03:10 1177.25 01-JAN-17:10
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
MiscPlug:InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:10 588.62 01-JAN-17:10
Fans:Electricity 120.13 1385.33 10-FEB-13:00 10972.24 16-JUN-16:20
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Ventilation (simple):Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricityProduced:Facility 82.69 -0.00 29-NOV-07:10 12168.93 12-MAY-12:30
ElectricityProduced:Plant 82.69 -0.00 29-NOV-07:10 12168.93 12-MAY-12:30
Photovoltaic:ElectricityProduced 86.26 0.00 01-JAN-00:10 12674.43 12-MAY-12:30
PowerConversion:ElectricityProduced -3.57 -505.50 12-MAY-12:30 0.00 01-JAN-00:10
Electricity:Plant 0.41 12.93 01-JAN-00:10 12.93 01-JAN-07:10
Cogeneration:Electricity 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
DCtoACInverter Ancillary:Cogeneration:Electricity 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricityPurchased:Facility 753.53 4638.96 26-MAR-13:10 59134.42 25-AUG-16:20
ElectricityPurchased:Plant 753.53 4638.96 26-MAR-13:10 59134.42 25-AUG-16:20
Cogeneration:ElectricityPurchased 753.53 4638.96 26-MAR-13:10 59134.42 25-AUG-16:20
General:Cogeneration:ElectricityPurchased 753.53 4638.96 26-MAR-13:10 59134.42 25-AUG-16:20
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricityNet:Facility 753.53 4638.96 26-MAR-13:10 59134.42 25-AUG-16:20
ElectricityNet:Plant 753.53 4638.96 26-MAR-13:10 59134.42 25-AUG-16:20
Cogeneration:ElectricityNet 753.53 4638.96 26-MAR-13:10 59134.42 25-AUG-16:20
General:Cogeneration:ElectricityNet 753.53 4638.96 26-MAR-13:10 59134.42 25-AUG-16:20
Electricity:HVAC 335.52 1446.71 10-FEB-13:00 42397.41 28-JUN-16:20
HeatRecovery:Electricity 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:HeatRecovery:Electricity 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Fans:Electricity 120.13 1385.33 10-FEB-13:00 10972.24 16-JUN-16:20
Cooling:Electricity 213.58 0.00 01-JAN-00:30 31651.86 28-JUN-16:20
General:Cooling:Electricity 213.58 0.00 01-JAN-00:30 31651.86 28-JUN-16:20
Heating:Electricity 1.82 0.00 01-JAN-13:20 4505.53 01-JAN-06:00
General:Heating:Electricity 1.82 0.00 01-JAN-13:20 4505.53 01-JAN-06:00
ExteriorLights:Electricity 22.83 0.00 01-JAN-07:30 1451.66 01-JAN-00:10
General:ExteriorLights:Electricity 22.83 0.00 01-JAN-07:30 1451.66 01-JAN-00:10
Pumps:Electricity 0.41 12.93 01-JAN-00:10 12.93 01-JAN-07:10
General:Pumps:Electricity 0.41 12.93 01-JAN-00:10 12.93 01-JAN-07:10


Annual and Peak Values - Natural Gas

Natural Gas Annual Value [GJ] Natural Gas Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Natural Gas Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
NaturalGas:Facility 319.01 0.00 01-JAN-03:50 23106.97 22-JAN-07:50
NaturalGas:Plant 319.01 0.00 01-JAN-03:50 23106.97 22-JAN-07:50
WaterSystems:NaturalGas 319.01 0.00 01-JAN-03:50 23106.97 22-JAN-07:50
Water Heater:WaterSystems:NaturalGas 319.01 0.00 01-JAN-03:50 23106.97 22-JAN-07:50


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Cooling Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [m3/s] Timestamp of Maximum {TIMESTAMP}
Water:Facility 1672.95 0.00 01-JAN-02:10 0.00 01-JAN-07:30
Water:Plant 1672.95 0.00 01-JAN-02:10 0.00 01-JAN-07:30
WaterSystems:Water 1672.95 0.00 01-JAN-02:10 0.00 01-JAN-07:30
WaterUse:WaterSystems:Water 1672.95 0.00 01-JAN-02:10 0.00 01-JAN-07:30
MainsWater:Facility 1672.95 0.00 01-JAN-02:10 0.00 01-JAN-07:30
MainsWater:Plant 1672.95 0.00 01-JAN-02:10 0.00 01-JAN-07:30
WaterSystems:MainsWater 1672.95 0.00 01-JAN-02:10 0.00 01-JAN-07:30
WaterUse:WaterSystems:MainsWater 1672.95 0.00 01-JAN-02:10 0.00 01-JAN-07:30
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [kg/s] Timestamp of Maximum {TIMESTAMP}
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:10 0.000 01-JAN-00:10
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:10 0.000 01-JAN-00:10


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [m3/s] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum {TIMESTAMP} Maximum Value [L] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
EnergyTransfer:Facility 1907.66 7046.43 11-NOV-15:00 211529.34 28-JUN-16:20
EnergyTransfer:Building 711.22 216.88 10-SEP-07:00 87899.52 30-JUN-16:20
EnergyTransfer:Zone:G SW APARTMENT 23.74 0.05 27-APR-13:20 3832.15 28-SEP-16:20
Heating:EnergyTransfer 7.15 0.00 01-JAN-18:10 7076.84 07-DEC-06:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 0.05 0.00 01-JAN-00:10 109.21 28-JUN-08:10
General:Heating:EnergyTransfer 7.15 0.00 01-JAN-18:10 7076.84 07-DEC-06:00
General:Heating:EnergyTransfer:Zone:G SW APARTMENT 0.05 0.00 01-JAN-00:10 109.21 28-JUN-08:10
Cooling:EnergyTransfer 704.07 0.00 01-APR-09:20 87659.08 30-JUN-16:20
Cooling:EnergyTransfer:Zone:G SW APARTMENT 23.69 0.00 18-FEB-15:10 3832.15 28-SEP-16:20
General:Cooling:EnergyTransfer 704.07 0.00 01-APR-09:20 87659.08 30-JUN-16:20
General:Cooling:EnergyTransfer:Zone:G SW APARTMENT 23.69 0.00 18-FEB-15:10 3832.15 28-SEP-16:20
EnergyTransfer:Zone:G NW APARTMENT 19.93 0.02 07-NOV-14:20 2285.45 22-JUL-18:00
Heating:EnergyTransfer:Zone:G NW APARTMENT 0.02 0.00 01-JAN-00:10 156.10 01-JAN-08:00
General:Heating:EnergyTransfer:Zone:G NW APARTMENT 0.02 0.00 01-JAN-00:10 156.10 01-JAN-08:00
Cooling:EnergyTransfer:Zone:G NW APARTMENT 19.92 0.00 01-JAN-01:00 2285.45 22-JUL-18:00
General:Cooling:EnergyTransfer:Zone:G NW APARTMENT 19.92 0.00 01-JAN-01:00 2285.45 22-JUL-18:00
EnergyTransfer:Zone:OFFICE 24.05 0.01 14-MAR-23:30 4535.90 28-AUG-06:20
Heating:EnergyTransfer:Zone:OFFICE 3.61 0.00 01-JAN-00:10 908.73 28-JUN-17:10
General:Heating:EnergyTransfer:Zone:OFFICE 3.61 0.00 01-JAN-00:10 908.73 28-JUN-17:10
Cooling:EnergyTransfer:Zone:OFFICE 20.44 0.00 01-JAN-12:30 4535.90 28-AUG-06:20
General:Cooling:EnergyTransfer:Zone:OFFICE 20.44 0.00 01-JAN-12:30 4535.90 28-AUG-06:20
EnergyTransfer:Zone:G NE APARTMENT 20.28 0.01 06-JUL-06:40 1975.57 28-SEP-09:00
Heating:EnergyTransfer:Zone:G NE APARTMENT 0.02 0.00 01-JAN-08:50 170.52 01-JAN-05:00
General:Heating:EnergyTransfer:Zone:G NE APARTMENT 0.02 0.00 01-JAN-08:50 170.52 01-JAN-05:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 20.27 0.00 01-JAN-00:10 1964.86 28-SEP-09:00
General:Cooling:EnergyTransfer:Zone:G NE APARTMENT 20.27 0.00 01-JAN-00:10 1964.86 28-SEP-09:00
EnergyTransfer:Zone:G N1 APARTMENT 16.92 0.00 28-MAR-15:50 1722.20 21-OCT-16:30
Heating:EnergyTransfer:Zone:G N1 APARTMENT 0.01 0.00 01-JAN-00:10 60.59 13-APR-09:50
General:Heating:EnergyTransfer:Zone:G N1 APARTMENT 0.01 0.00 01-JAN-00:10 60.59 13-APR-09:50
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 16.91 0.00 02-JAN-13:40 1722.20 21-OCT-16:30
General:Cooling:EnergyTransfer:Zone:G N1 APARTMENT 16.91 0.00 02-JAN-13:40 1722.20 21-OCT-16:30
EnergyTransfer:Zone:G N2 APARTMENT 16.95 0.00 08-NOV-13:30 1715.95 21-OCT-16:30
Heating:EnergyTransfer:Zone:G N2 APARTMENT 0.01 0.00 01-JAN-00:10 60.50 13-APR-09:50
General:Heating:EnergyTransfer:Zone:G N2 APARTMENT 0.01 0.00 01-JAN-00:10 60.50 13-APR-09:50
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 16.94 0.00 02-JAN-13:40 1715.95 21-OCT-16:30
General:Cooling:EnergyTransfer:Zone:G N2 APARTMENT 16.94 0.00 02-JAN-13:40 1715.95 21-OCT-16:30
EnergyTransfer:Zone:G S1 APARTMENT 21.95 0.01 11-APR-08:20 3117.82 28-SEP-16:20
Heating:EnergyTransfer:Zone:G S1 APARTMENT 0.07 0.00 01-JAN-00:10 115.74 28-JUN-09:10
General:Heating:EnergyTransfer:Zone:G S1 APARTMENT 0.07 0.00 01-JAN-00:10 115.74 28-JUN-09:10
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 21.88 0.00 18-FEB-15:10 3117.82 28-SEP-16:20
General:Cooling:EnergyTransfer:Zone:G S1 APARTMENT 21.88 0.00 18-FEB-15:10 3117.82 28-SEP-16:20
EnergyTransfer:Zone:G S2 APARTMENT 23.18 0.03 23-MAR-15:20 3142.65 28-SEP-16:20
Heating:EnergyTransfer:Zone:G S2 APARTMENT 0.05 0.00 01-JAN-00:10 110.27 28-JUN-08:40
General:Heating:EnergyTransfer:Zone:G S2 APARTMENT 0.05 0.00 01-JAN-00:10 110.27 28-JUN-08:40
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 23.13 0.00 18-FEB-15:10 3142.65 28-SEP-16:20
General:Cooling:EnergyTransfer:Zone:G S2 APARTMENT 23.13 0.00 18-FEB-15:10 3142.65 28-SEP-16:20
EnergyTransfer:Zone:M SW APARTMENT 53.34 0.05 03-APR-08:50 8497.38 01-NOV-16:20
Heating:EnergyTransfer:Zone:M SW APARTMENT 0.10 0.00 01-JAN-00:10 234.19 10-JUL-10:40
General:Heating:EnergyTransfer:Zone:M SW APARTMENT 0.10 0.00 01-JAN-00:10 234.19 10-JUL-10:40
Cooling:EnergyTransfer:Zone:M SW APARTMENT 53.23 0.00 14-MAR-13:40 8497.38 01-NOV-16:20
General:Cooling:EnergyTransfer:Zone:M SW APARTMENT 53.23 0.00 14-MAR-13:40 8497.38 01-NOV-16:20
EnergyTransfer:Zone:M NW APARTMENT 43.31 0.01 07-NOV-13:00 5363.96 29-JUN-18:00
Heating:EnergyTransfer:Zone:M NW APARTMENT 0.02 0.00 01-JAN-00:10 106.36 31-JAN-13:20
General:Heating:EnergyTransfer:Zone:M NW APARTMENT 0.02 0.00 01-JAN-00:10 106.36 31-JAN-13:20
Cooling:EnergyTransfer:Zone:M NW APARTMENT 43.29 0.00 02-JAN-13:50 5363.96 29-JUN-18:00
General:Cooling:EnergyTransfer:Zone:M NW APARTMENT 43.29 0.00 02-JAN-13:50 5363.96 29-JUN-18:00
EnergyTransfer:Zone:M SE APARTMENT 53.88 0.05 01-SEP-06:00 7769.90 28-SEP-16:20
Heating:EnergyTransfer:Zone:M SE APARTMENT 0.03 0.00 01-JAN-00:10 209.02 28-JUN-08:10
General:Heating:EnergyTransfer:Zone:M SE APARTMENT 0.03 0.00 01-JAN-00:10 209.02 28-JUN-08:10
Cooling:EnergyTransfer:Zone:M SE APARTMENT 53.85 0.00 14-MAR-13:40 7769.90 28-SEP-16:20
General:Cooling:EnergyTransfer:Zone:M SE APARTMENT 53.85 0.00 14-MAR-13:40 7769.90 28-SEP-16:20
EnergyTransfer:Zone:M NE APARTMENT 44.09 0.01 09-JUL-06:40 4404.69 27-MAY-10:50
Heating:EnergyTransfer:Zone:M NE APARTMENT 0.01 0.00 01-JAN-00:10 103.56 14-JAN-13:20
General:Heating:EnergyTransfer:Zone:M NE APARTMENT 0.01 0.00 01-JAN-00:10 103.56 14-JAN-13:20
Cooling:EnergyTransfer:Zone:M NE APARTMENT 44.08 0.00 01-JAN-05:00 4391.87 27-MAY-10:50
General:Cooling:EnergyTransfer:Zone:M NE APARTMENT 44.08 0.00 01-JAN-05:00 4391.87 27-MAY-10:50
EnergyTransfer:Zone:M N1 APARTMENT 36.25 0.01 15-MAY-07:50 3738.90 21-OCT-16:30
Heating:EnergyTransfer:Zone:M N1 APARTMENT 0.02 0.00 01-JAN-00:10 102.05 14-JAN-13:20
General:Heating:EnergyTransfer:Zone:M N1 APARTMENT 0.02 0.00 01-JAN-00:10 102.05 14-JAN-13:20
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 36.23 0.00 03-JAN-11:50 3718.68 21-OCT-16:30
General:Cooling:EnergyTransfer:Zone:M N1 APARTMENT 36.23 0.00 03-JAN-11:50 3718.68 21-OCT-16:30
EnergyTransfer:Zone:M N2 APARTMENT 36.33 0.05 06-JAN-12:40 3738.00 21-OCT-16:30
Heating:EnergyTransfer:Zone:M N2 APARTMENT 0.02 0.00 01-JAN-00:10 101.39 14-JAN-13:20
General:Heating:EnergyTransfer:Zone:M N2 APARTMENT 0.02 0.00 01-JAN-00:10 101.39 14-JAN-13:20
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 36.31 0.00 03-JAN-11:50 3717.83 21-OCT-16:30
General:Cooling:EnergyTransfer:Zone:M N2 APARTMENT 36.31 0.00 03-JAN-11:50 3717.83 21-OCT-16:30
EnergyTransfer:Zone:M S1 APARTMENT 48.28 0.03 19-JUL-11:20 7010.95 01-NOV-16:20
Heating:EnergyTransfer:Zone:M S1 APARTMENT 0.17 0.00 01-JAN-00:10 264.34 10-JUL-11:40
General:Heating:EnergyTransfer:Zone:M S1 APARTMENT 0.17 0.00 01-JAN-00:10 264.34 10-JUL-11:40
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 48.11 0.00 14-MAR-13:40 7010.95 01-NOV-16:20
General:Cooling:EnergyTransfer:Zone:M S1 APARTMENT 48.11 0.00 14-MAR-13:40 7010.95 01-NOV-16:20
EnergyTransfer:Zone:M S2 APARTMENT 48.41 0.02 21-MAR-15:50 6996.68 01-NOV-16:20
Heating:EnergyTransfer:Zone:M S2 APARTMENT 0.16 0.00 01-JAN-00:10 263.84 10-JUL-11:40
General:Heating:EnergyTransfer:Zone:M S2 APARTMENT 0.16 0.00 01-JAN-00:10 263.84 10-JUL-11:40
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 48.25 0.00 14-MAR-13:40 6996.68 01-NOV-16:20
General:Cooling:EnergyTransfer:Zone:M S2 APARTMENT 48.25 0.00 14-MAR-13:40 6996.68 01-NOV-16:20
EnergyTransfer:Zone:T SW APARTMENT 26.18 0.01 21-OCT-09:30 5375.63 07-SEP-16:10
Heating:EnergyTransfer:Zone:T SW APARTMENT 0.26 0.00 01-JAN-00:10 955.39 07-DEC-06:00
General:Heating:EnergyTransfer:Zone:T SW APARTMENT 0.26 0.00 01-JAN-00:10 955.39 07-DEC-06:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 25.93 0.00 01-JAN-01:20 5375.63 07-SEP-16:10
General:Cooling:EnergyTransfer:Zone:T SW APARTMENT 25.93 0.00 01-JAN-01:20 5375.63 07-SEP-16:10
EnergyTransfer:Zone:T NW APARTMENT 23.22 0.01 27-AUG-06:00 3634.36 28-JUN-17:30
Heating:EnergyTransfer:Zone:T NW APARTMENT 0.82 0.00 01-JAN-13:00 1297.72 07-DEC-06:00
General:Heating:EnergyTransfer:Zone:T NW APARTMENT 0.82 0.00 01-JAN-13:00 1297.72 07-DEC-06:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 22.40 0.00 01-JAN-00:10 3634.36 28-JUN-17:30
General:Cooling:EnergyTransfer:Zone:T NW APARTMENT 22.40 0.00 01-JAN-00:10 3634.36 28-JUN-17:30
EnergyTransfer:Zone:T SE APARTMENT 26.27 0.03 06-JAN-13:30 4780.61 08-SEP-16:10
Heating:EnergyTransfer:Zone:T SE APARTMENT 0.23 0.00 01-JAN-00:10 961.70 07-DEC-06:00
General:Heating:EnergyTransfer:Zone:T SE APARTMENT 0.23 0.00 01-JAN-00:10 961.70 07-DEC-06:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 26.04 0.00 01-JAN-01:00 4780.61 08-SEP-16:10
General:Cooling:EnergyTransfer:Zone:T SE APARTMENT 26.04 0.00 01-JAN-01:00 4780.61 08-SEP-16:10
EnergyTransfer:Zone:T NE APARTMENT 23.43 0.00 26-JAN-12:40 2946.12 27-MAY-10:50
Heating:EnergyTransfer:Zone:T NE APARTMENT 0.75 0.00 01-JAN-11:30 1321.50 07-DEC-06:00
General:Heating:EnergyTransfer:Zone:T NE APARTMENT 0.75 0.00 01-JAN-11:30 1321.50 07-DEC-06:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 22.69 0.00 01-JAN-00:10 2940.42 27-MAY-10:50
General:Cooling:EnergyTransfer:Zone:T NE APARTMENT 22.69 0.00 01-JAN-00:10 2940.42 27-MAY-10:50
EnergyTransfer:Zone:T N1 APARTMENT 18.39 0.00 31-MAR-15:40 2378.22 28-JUN-17:40
Heating:EnergyTransfer:Zone:T N1 APARTMENT 0.30 0.00 01-JAN-12:00 824.81 07-DEC-06:00
General:Heating:EnergyTransfer:Zone:T N1 APARTMENT 0.30 0.00 01-JAN-12:00 824.81 07-DEC-06:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 18.09 0.00 01-JAN-00:10 2378.22 28-JUN-17:40
General:Cooling:EnergyTransfer:Zone:T N1 APARTMENT 18.09 0.00 01-JAN-00:10 2378.22 28-JUN-17:40
EnergyTransfer:Zone:T N2 APARTMENT 18.44 0.00 31-MAR-15:50 2362.47 28-JUN-17:40
Heating:EnergyTransfer:Zone:T N2 APARTMENT 0.30 0.00 01-JAN-11:50 826.88 07-DEC-06:00
General:Heating:EnergyTransfer:Zone:T N2 APARTMENT 0.30 0.00 01-JAN-11:50 826.88 07-DEC-06:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 18.14 0.00 01-JAN-00:10 2362.47 28-JUN-17:40
General:Cooling:EnergyTransfer:Zone:T N2 APARTMENT 18.14 0.00 01-JAN-00:10 2362.47 28-JUN-17:40
EnergyTransfer:Zone:T S1 APARTMENT 22.16 0.00 10-MAY-06:50 4265.44 01-NOV-16:10
Heating:EnergyTransfer:Zone:T S1 APARTMENT 0.07 0.00 01-JAN-00:10 445.08 07-DEC-06:00
General:Heating:EnergyTransfer:Zone:T S1 APARTMENT 0.07 0.00 01-JAN-00:10 445.08 07-DEC-06:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 22.09 0.00 01-JAN-04:10 4265.44 01-NOV-16:10
General:Cooling:EnergyTransfer:Zone:T S1 APARTMENT 22.09 0.00 01-JAN-04:10 4265.44 01-NOV-16:10
EnergyTransfer:Zone:T S2 APARTMENT 22.24 0.00 07-AUG-08:20 4249.05 01-NOV-16:10
Heating:EnergyTransfer:Zone:T S2 APARTMENT 0.06 0.00 01-JAN-00:10 443.76 07-DEC-06:00
General:Heating:EnergyTransfer:Zone:T S2 APARTMENT 0.06 0.00 01-JAN-00:10 443.76 07-DEC-06:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 22.18 0.00 01-JAN-04:10 4249.05 01-NOV-16:10
General:Cooling:EnergyTransfer:Zone:T S2 APARTMENT 22.18 0.00 01-JAN-04:10 4249.05 01-NOV-16:10
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
PlantLoopHeatingDemand:Facility 244.45 120.50 26-JUL-01:40 17523.65 23-JAN-07:10
PlantLoopHeatingDemand:Plant 244.45 120.50 26-JUL-01:40 17523.65 23-JAN-07:10
WaterSystems:PlantLoopHeatingDemand 244.45 120.50 26-JUL-01:40 17523.65 23-JAN-07:10
General:WaterSystems:PlantLoopHeatingDemand 244.45 120.50 26-JUL-01:40 17523.65 23-JAN-07:10
EnergyTransfer:HVAC 951.99 71.20 05-JUN-06:00 115524.97 11-AUG-16:20
HeatRecoveryForHeating:EnergyTransfer 100.60 0.00 14-JAN-14:50 14673.26 05-DEC-07:00
HeatRecoveryForCooling:EnergyTransfer 47.46 0.00 01-JAN-00:10 11968.68 17-JUN-16:00
CoolingCoils:EnergyTransfer 800.22 0.00 01-JAN-00:30 107538.86 11-AUG-16:20
HeatingCoils:EnergyTransfer 3.72 0.00 01-JAN-13:20 8262.86 07-DEC-06:00
EnergyTransfer:Plant 244.45 120.50 26-JUL-01:40 17521.85 23-JAN-07:10
WaterSystems:EnergyTransfer 244.45 120.50 26-JUL-01:40 17521.85 23-JAN-07:10
WaterUse:WaterSystems:EnergyTransfer 244.45 120.50 26-JUL-01:40 17521.85 23-JAN-07:10
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Annual Building Sensible Heat Gain Components

HVAC Zone Eq & Other Sensible Air Heating [GJ] HVAC Zone Eq & Other Sensible Air Cooling [GJ] HVAC Terminal Unit Sensible Air Heating [GJ] HVAC Terminal Unit Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 1.132 -1.379 0.000 -23.390 0.000 0.000 3.527 0.470 12.213 11.938 0.000 0.264 0.467 0.000 -4.150 0.000 -1.091 -0.001
G NW APARTMENT 1.256 -1.245 0.015 -19.924 0.000 0.000 3.640 0.470 12.213 7.258 0.000 0.297 1.206 0.000 -4.063 0.000 -1.123 -0.000
OFFICE 0.000 0.000 3.610 -20.439 0.000 0.000 2.004 4.771 7.520 11.776 0.000 0.187 0.000 0.000 -4.551 0.000 -0.481 -4.397
G NE APARTMENT 1.254 -1.255 0.016 -20.269 0.000 0.000 3.639 0.470 12.213 7.265 0.000 0.297 1.329 0.000 -3.795 0.000 -1.165 -0.000
G N1 APARTMENT 1.255 -1.290 0.001 -16.859 0.000 0.000 3.611 0.470 12.213 2.780 0.000 0.179 1.236 0.000 -2.538 0.000 -1.058 -0.000
G N2 APARTMENT 1.255 -1.291 0.001 -16.892 0.000 0.000 3.610 0.470 12.213 2.779 0.000 0.179 1.274 0.000 -2.539 0.000 -1.059 -0.000
G S1 APARTMENT 1.132 -1.409 0.000 -21.530 0.000 0.000 3.511 0.470 12.213 7.654 0.000 0.160 1.232 0.000 -2.530 0.000 -0.902 -0.000
G S2 APARTMENT 1.131 -1.411 0.000 -22.798 0.000 0.000 3.510 0.470 12.213 7.640 0.000 0.159 2.515 0.000 -2.540 0.000 -0.889 -0.000
M SW APARTMENT 2.262 -2.819 0.000 -52.574 0.000 0.000 7.022 0.940 24.426 23.708 0.000 0.757 7.358 0.000 -8.421 0.000 -2.659 -0.000
M NW APARTMENT 2.508 -2.604 0.009 -43.183 0.000 0.000 7.204 0.940 24.426 14.429 0.000 0.852 6.801 0.000 -8.387 0.000 -2.995 -0.000
M SE APARTMENT 2.256 -2.843 0.000 -53.229 0.000 0.000 7.019 0.940 24.426 23.955 0.000 0.756 7.438 0.000 -8.160 0.000 -2.557 -0.000
M NE APARTMENT 2.504 -2.618 0.010 -43.964 0.000 0.000 7.206 0.940 24.426 14.417 0.000 0.852 7.185 0.000 -7.824 0.000 -3.133 -0.000
M N1 APARTMENT 2.508 -2.661 0.000 -36.051 0.000 0.000 7.169 0.940 24.426 5.551 0.000 0.514 5.611 0.000 -5.213 0.000 -2.793 -0.000
M N2 APARTMENT 2.507 -2.662 0.000 -36.133 0.000 0.000 7.168 0.940 24.426 5.548 0.000 0.514 5.700 0.000 -5.214 0.000 -2.796 -0.000
M S1 APARTMENT 2.265 -2.847 0.000 -47.366 0.000 0.000 7.012 0.940 24.426 15.235 0.000 0.457 7.085 0.000 -5.098 0.000 -2.110 -0.000
M S2 APARTMENT 2.265 -2.848 0.000 -47.507 0.000 0.000 7.012 0.940 24.426 15.231 0.000 0.457 7.227 0.000 -5.099 0.000 -2.105 -0.001
T SW APARTMENT 1.132 -1.259 0.361 -25.904 0.000 0.000 3.611 0.470 12.213 11.789 0.000 0.497 2.489 0.000 -3.838 0.000 -1.560 -0.000
T NW APARTMENT 1.259 -1.112 1.132 -22.859 0.000 0.000 3.724 0.470 12.213 7.213 0.000 0.561 2.658 0.000 -3.742 0.000 -1.517 -0.000
T SE APARTMENT 1.128 -1.282 0.340 -25.997 0.000 0.000 3.608 0.470 12.213 11.905 0.000 0.497 2.418 0.000 -3.724 0.000 -1.576 -0.000
T NE APARTMENT 1.254 -1.122 1.055 -23.123 0.000 0.000 3.729 0.470 12.213 7.241 0.000 0.560 2.826 0.000 -3.504 0.000 -1.599 -0.000
T N1 APARTMENT 1.258 -1.138 0.470 -18.387 0.000 0.000 3.707 0.470 12.213 2.786 0.000 0.338 1.935 0.000 -2.328 0.000 -1.325 -0.000
T N2 APARTMENT 1.258 -1.139 0.471 -18.432 0.000 0.000 3.708 0.470 12.213 2.782 0.000 0.338 1.987 0.000 -2.327 0.000 -1.329 -0.000
T S1 APARTMENT 1.131 -1.316 0.087 -21.931 0.000 0.000 3.576 0.470 12.213 7.578 0.000 0.300 1.568 0.000 -2.373 0.000 -1.302 -0.001
T S2 APARTMENT 1.131 -1.317 0.087 -22.012 0.000 0.000 3.575 0.470 12.213 7.573 0.000 0.300 1.652 0.000 -2.373 0.000 -1.299 -0.000
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 0.000 5.539 8.630 0.000 1.068 0.000 0.060 0.000 0.000 -0.397 0.000 -0.139 -14.762
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 0.000 5.037 8.630 1.874 3.090 0.000 3.965 0.000 0.000 -1.281 0.000 -12.416 -8.900
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 0.000 10.520 17.261 0.000 2.111 0.000 0.100 0.000 0.000 -0.876 0.000 -0.242 -28.873
Total Facility 37.038 -40.864 7.664 -700.753 0.000 0.000 134.198 53.863 387.990 242.299 0.000 14.401 81.198 0.000 -106.883 0.000 -53.219 -56.937


Peak Cooling Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [W] HVAC Zone Eq & Other Sensible Air Cooling [W] HVAC Terminal Unit Sensible Air Heating [W] HVAC Terminal Unit Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 17-NOV-17:01 0.00 -80.30 0.00 -5033.67 0.00 0.00 0.00 28.06 588.62 237.39 0.00 0.00 4300.69 0.00 -0.00 0.00 -40.79 0.00
G NW APARTMENT 20-SEP-06:01 0.00 21.53 0.00 -4954.89 0.00 0.00 125.49 18.23 382.60 0.00 0.00 0.00 4490.76 0.00 -82.19 0.00 -1.54 0.00
OFFICE 10-OCT-06:01 0.00 0.00 0.00 -6468.82 0.00 0.00 0.00 75.20 194.98 0.00 0.00 0.00 6594.07 0.00 -367.73 0.00 -27.70 0.00
G NE APARTMENT 20-SEP-06:01 0.00 20.50 0.00 -4616.28 0.00 0.00 125.53 18.23 382.60 0.00 0.00 0.00 4151.90 0.00 -80.90 0.00 -1.59 0.00
G N1 APARTMENT 15-NOV-20:12 0.00 -87.13 0.00 -3875.73 0.00 0.00 129.60 44.89 523.87 0.00 0.00 0.00 3489.68 0.00 -212.32 0.00 -12.86 0.00
G N2 APARTMENT 15-NOV-20:12 0.00 -85.86 0.00 -3879.40 0.00 0.00 130.63 44.89 523.87 0.00 0.00 0.00 3489.61 0.00 -211.00 0.00 -12.74 0.00
G S1 APARTMENT 17-NOV-17:01 0.00 -83.30 0.00 -4053.69 0.00 0.00 0.00 28.06 588.62 27.95 0.00 0.00 3517.21 0.00 -0.00 0.00 -24.85 0.00
G S2 APARTMENT 17-NOV-17:01 0.00 -82.93 0.00 -4135.70 0.00 0.00 0.00 28.06 588.62 28.37 0.00 0.00 3598.41 0.00 -0.00 0.00 -24.82 0.00
M SW APARTMENT 17-NOV-17:01 0.00 -157.41 0.00 -11409.53 0.00 0.00 0.00 56.11 1177.25 455.62 0.00 0.00 9994.81 0.00 -0.00 0.00 -116.86 0.00
M NW APARTMENT 20-SEP-06:01 0.00 55.34 0.00 -11216.51 0.00 0.00 258.57 36.47 765.21 0.00 0.00 0.00 10245.98 0.00 -142.68 0.00 -2.38 0.00
M SE APARTMENT 17-NOV-17:01 0.00 -158.76 0.00 -10494.15 0.00 0.00 0.00 56.11 1177.25 0.00 0.00 0.00 9733.30 0.00 -196.62 0.00 -117.12 0.00
M NE APARTMENT 20-SEP-06:01 0.00 52.69 0.00 -10327.16 0.00 0.00 258.68 36.47 765.21 0.00 0.00 0.00 9355.96 0.00 -139.28 0.00 -2.58 0.00
M N1 APARTMENT 11-MAR-18:52 0.00 -147.91 0.00 -8716.57 0.00 0.00 263.83 75.75 1177.25 0.00 0.00 0.00 7800.17 0.00 -394.30 0.00 -58.21 0.00
M N2 APARTMENT 11-MAR-18:52 0.00 -147.82 0.00 -8699.11 0.00 0.00 264.03 75.75 1177.25 0.00 0.00 0.00 7782.04 0.00 -393.97 0.00 -58.17 0.00
M S1 APARTMENT 17-NOV-17:01 0.00 -164.11 0.00 -9083.38 0.00 0.00 0.00 56.11 1177.25 45.86 0.00 0.00 8039.53 0.00 -0.00 0.00 -71.26 0.00
M S2 APARTMENT 17-NOV-17:01 0.00 -164.14 0.00 -9069.54 0.00 0.00 0.00 56.11 1177.25 45.88 0.00 0.00 8025.71 0.00 -0.00 0.00 -71.26 0.00
T SW APARTMENT 17-NOV-17:01 0.00 -76.58 0.00 -6556.40 0.00 0.00 0.00 28.06 588.62 211.56 0.00 0.00 5881.78 0.00 -0.00 0.00 -77.04 0.00
T NW APARTMENT 20-SEP-06:01 0.00 32.07 0.00 -6473.50 0.00 0.00 130.68 18.23 382.60 0.00 0.00 0.00 5977.76 0.00 -66.90 0.00 -0.94 0.00
T SE APARTMENT 17-NOV-17:01 0.00 -77.55 0.00 -5888.65 0.00 0.00 0.00 28.06 588.62 0.00 0.00 0.00 5533.96 0.00 -107.15 0.00 -77.29 0.00
T NE APARTMENT 20-SEP-06:01 0.00 30.11 0.00 -5827.17 0.00 0.00 130.75 18.23 382.60 0.00 0.00 0.00 5331.67 0.00 -65.04 0.00 -1.14 0.00
T N1 APARTMENT 20-SEP-06:01 0.00 27.85 0.00 -5258.48 0.00 0.00 130.33 18.23 382.60 0.00 0.00 0.00 4741.26 0.00 -40.93 0.00 -0.88 0.00
T N2 APARTMENT 20-SEP-06:01 0.00 27.80 0.00 -5238.02 0.00 0.00 130.34 18.23 382.60 0.00 0.00 0.00 4720.83 0.00 -40.91 0.00 -0.89 0.00
T S1 APARTMENT 17-NOV-17:01 0.00 -79.98 0.00 -5340.59 0.00 0.00 0.00 28.06 588.62 16.31 0.00 0.00 4834.58 0.00 -0.00 0.00 -46.99 0.00
T S2 APARTMENT 17-NOV-17:01 0.00 -80.03 0.00 -5320.08 0.00 0.00 0.00 28.06 588.62 16.38 0.00 0.00 4814.05 0.00 -0.00 0.00 -47.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 20-SEP-06:01 0.00 751.55 0.00 -162158.17 0.00 0.00 5098.09 1735.16 12172.98 0.00 0.00 0.00 146196.17 0.00 -2041.00 0.00 -1754.77 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [W] HVAC Zone Eq & Other Sensible Air Cooling [W] HVAC Terminal Unit Sensible Air Heating [W] HVAC Terminal Unit Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 16-MAY-16:06 154.58 0.00 0.00 0.00 0.00 0.00 0.00 28.06 588.62 1001.03 0.00 57.99 0.00 0.00 -0.00 0.00 0.00 -1830.29
G NW APARTMENT 01-JAN-08:00 -193.37 0.00 349.46 0.00 0.00 0.00 165.74 18.23 382.60 0.00 0.00 0.00 0.00 0.00 -528.76 0.00 -64.99 -128.92
OFFICE 28-JUN-16:01 0.00 0.00 1040.04 0.00 0.00 0.00 0.00 75.20 194.98 690.61 0.00 83.17 0.00 0.00 -0.00 0.00 0.00 -2084.00
G NE APARTMENT 01-JAN-05:00 -186.18 0.00 356.70 0.00 0.00 0.00 194.99 8.42 223.68 0.00 0.00 0.00 6.94 0.00 -549.51 0.00 -55.04 0.00
G N1 APARTMENT 18-MAY-08:15 70.28 0.00 0.00 0.00 0.00 0.00 36.96 5.61 394.38 154.30 0.00 3.84 0.00 0.00 -0.00 0.00 0.00 -665.36
G N2 APARTMENT 18-MAY-08:15 70.07 0.00 0.00 0.00 0.00 0.00 36.91 5.61 394.38 154.05 0.00 3.82 0.00 0.00 -0.00 0.00 0.00 -664.84
G S1 APARTMENT 28-JUN-08:62 118.61 0.00 0.00 0.00 0.00 0.00 0.00 5.61 394.38 253.99 0.00 23.84 0.00 0.00 -0.00 0.00 0.00 -796.42
G S2 APARTMENT 28-JUN-08:62 118.15 0.00 0.00 0.00 0.00 0.00 0.00 5.61 394.38 252.72 0.00 23.80 0.00 0.00 -0.00 0.00 0.00 -794.65
M SW APARTMENT 28-JUN-08:62 234.48 0.00 0.00 0.00 0.00 0.00 0.00 11.22 788.75 837.82 0.00 112.76 0.00 0.00 -0.00 0.00 0.00 -1985.03
M NW APARTMENT 23-JUN-07:05 152.35 0.00 0.00 0.00 0.00 0.00 113.15 16.83 776.98 738.19 0.00 49.10 0.00 0.00 -0.00 0.00 0.00 -1846.62
M SE APARTMENT 28-JUN-08:62 229.55 0.00 0.00 0.00 0.00 0.00 0.00 11.22 788.75 2474.02 0.00 111.69 0.00 0.00 -0.00 0.00 0.00 -3615.23
M NE APARTMENT 23-JUN-07:05 154.14 0.00 0.00 0.00 0.00 0.00 113.15 16.83 776.98 2290.35 0.00 49.30 0.00 0.00 -0.00 0.00 0.00 -3400.76
M N1 APARTMENT 23-JUN-07:05 150.27 0.00 0.00 0.00 0.00 0.00 113.15 16.83 776.98 607.99 0.00 28.60 0.00 0.00 -0.00 0.00 0.00 -1693.83
M N2 APARTMENT 23-JUN-07:05 150.18 0.00 0.00 0.00 0.00 0.00 113.15 16.83 776.98 607.88 0.00 28.58 0.00 0.00 -0.00 0.00 0.00 -1693.61
M S1 APARTMENT 21-AUG-16:06 290.34 0.00 0.00 0.00 0.00 0.00 0.00 56.11 1177.25 663.92 0.00 89.76 0.00 0.00 -0.00 0.00 0.00 -2277.39
M S2 APARTMENT 21-AUG-16:06 290.47 0.00 0.00 0.00 0.00 0.00 0.00 56.11 1177.25 663.81 0.00 89.78 0.00 0.00 -0.00 0.00 0.00 -2277.42
T SW APARTMENT 07-DEC-06:00 -208.06 0.00 1163.45 0.00 0.00 0.00 194.99 18.23 253.11 0.00 0.00 0.00 0.00 0.00 -612.57 0.00 -124.65 -684.50
T NW APARTMENT 07-DEC-06:00 -208.03 0.00 1505.75 0.00 0.00 0.00 194.99 18.23 253.11 0.00 0.00 0.00 0.00 0.00 -593.86 0.00 -124.65 -1045.54
T SE APARTMENT 07-DEC-06:00 -208.05 0.00 1169.75 0.00 0.00 0.00 194.99 18.23 253.11 0.00 0.00 0.00 0.00 0.00 -618.66 0.00 -124.65 -684.72
T NE APARTMENT 07-DEC-06:00 -208.03 0.00 1529.54 0.00 0.00 0.00 194.99 18.23 253.11 0.00 0.00 0.00 0.00 0.00 -599.37 0.00 -124.65 -1063.82
T N1 APARTMENT 07-DEC-06:00 -208.06 0.00 1032.87 0.00 0.00 0.00 194.99 18.23 253.11 0.00 0.00 0.00 0.00 0.00 -363.68 0.00 -75.19 -852.28
T N2 APARTMENT 07-DEC-06:00 -208.06 0.00 1034.95 0.00 0.00 0.00 194.99 18.23 253.11 0.00 0.00 0.00 0.00 0.00 -363.65 0.00 -75.19 -854.38
T S1 APARTMENT 07-DEC-06:00 -208.10 0.00 653.18 0.00 0.00 0.00 194.99 18.23 253.11 0.00 0.00 0.00 0.00 0.00 -380.83 0.00 -75.19 -455.39
T S2 APARTMENT 07-DEC-06:00 -208.10 0.00 651.86 0.00 0.00 0.00 194.99 18.23 253.11 0.00 0.00 0.00 0.00 0.00 -380.86 0.00 -75.19 -454.04
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 07-DEC-06:00 -7276.79 490.35 9247.45 -490.35 0.00 0.00 6917.73 1735.16 8015.55 0.00 0.00 0.00 1264.42 0.00 -17318.50 0.00 -2585.03 0.00



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Origin of D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Calculation Method for Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA Environment Name of Peak System Population - Ps Date and Time of Last Peak System Population - Ps
SPLIT GSW 0.3419 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.3419 0.0759 1.0000 Not calculated 0.0260 0.0759    
SPLIT GNW 0.3362 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.3362 0.0772 1.0000 Not calculated 0.0260 0.0772    
SPLIT OFFICE 0.4090 0.0000 4.7495 1.0000 Calculated from schedules 0.0381 0.4090 0.0932 1.0000 Not calculated 0.0381 0.0932    
SPLIT GNE 0.3124 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.3124 0.0831 1.0000 Not calculated 0.0260 0.0831    
SPLIT GN1 0.2679 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.2679 0.0969 1.0000 Not calculated 0.0260 0.0969    
SPLIT GN2 0.2674 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.2674 0.0970 1.0000 Not calculated 0.0260 0.0970    
SPLIT GS1 0.2732 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.2732 0.0950 1.0000 Not calculated 0.0260 0.0950    
SPLIT GS2 0.2789 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.2789 0.0930 1.0000 Not calculated 0.0260 0.0930    
SPLIT MSW 0.7785 0.0000 5.0000 1.0000 Calculated from schedules 0.0519 0.7785 0.0667 1.0000 Not calculated 0.0519 0.0667    
SPLIT MNW 0.7678 0.0000 5.0000 1.0000 Calculated from schedules 0.0519 0.7678 0.0676 1.0000 Not calculated 0.0519 0.0676    
SPLIT MSE 0.7149 0.0000 5.0000 1.0000 Calculated from schedules 0.0519 0.7149 0.0726 1.0000 Not calculated 0.0519 0.0726    
SPLIT MNE 0.7043 0.0000 5.0000 1.0000 Calculated from schedules 0.0519 0.7043 0.0737 1.0000 Not calculated 0.0519 0.0737    
SPLIT MN1 0.6039 0.0000 5.0000 1.0000 Calculated from schedules 0.0519 0.6039 0.0860 1.0000 Not calculated 0.0519 0.0860    
SPLIT MN2 0.6028 0.0000 5.0000 1.0000 Calculated from schedules 0.0519 0.6028 0.0861 1.0000 Not calculated 0.0519 0.0861    
SPLIT MS1 0.6142 0.0000 5.0000 1.0000 Calculated from schedules 0.0519 0.6142 0.0845 1.0000 Not calculated 0.0519 0.0845    
SPLIT MS2 0.6132 0.0000 5.0000 1.0000 Calculated from schedules 0.0519 0.6132 0.0847 1.0000 Not calculated 0.0519 0.0847    
SPLIT TSW 0.4499 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.4499 0.0577 1.0000 Not calculated 0.0260 0.0577    
SPLIT TNW 0.4489 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.4489 0.0578 1.0000 Not calculated 0.0260 0.0578    
SPLIT TSE 0.4031 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.4031 0.0644 1.0000 Not calculated 0.0260 0.0644    
SPLIT TNE 0.4020 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.4020 0.0646 1.0000 Not calculated 0.0260 0.0646    
SPLIT TN1 0.3611 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.3611 0.0719 1.0000 Not calculated 0.0260 0.0719    
SPLIT TN2 0.3596 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.3596 0.0722 1.0000 Not calculated 0.0260 0.0722    
SPLIT TS1 0.3629 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.3629 0.0715 1.0000 Not calculated 0.0260 0.0715    
SPLIT TS2 0.3614 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.3614 0.0718 1.0000 Not calculated 0.0260 0.0718    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Origin of D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Calculation Method for Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA Environment Name of Peak System Population - Ps Date and Time of Last Peak System Population - Ps
SPLIT GSW 0.3419 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.3419 1.0000 1.0000 Not calculated 0.0260 0.0759    
SPLIT GNW 0.3362 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.3362 1.0000 1.0000 Not calculated 0.0260 0.0772    
SPLIT OFFICE 0.4090 0.0000 4.7495 1.0000 Calculated from schedules 0.0381 0.4090 1.0000 1.0000 Not calculated 0.0381 0.0932    
SPLIT GNE 0.3124 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.3124 1.0000 1.0000 Not calculated 0.0260 0.0831    
SPLIT GN1 0.2679 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.2679 1.0000 1.0000 Not calculated 0.0260 0.0969    
SPLIT GN2 0.2674 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.2674 1.0000 1.0000 Not calculated 0.0260 0.0970    
SPLIT GS1 0.2732 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.2732 1.0000 1.0000 Not calculated 0.0260 0.0950    
SPLIT GS2 0.2789 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.2789 1.0000 1.0000 Not calculated 0.0260 0.0930    
SPLIT MSW 0.7785 0.0000 5.0000 1.0000 Calculated from schedules 0.0519 0.7785 1.0000 1.0000 Not calculated 0.0519 0.0667    
SPLIT MNW 0.7678 0.0000 5.0000 1.0000 Calculated from schedules 0.0519 0.7678 1.0000 1.0000 Not calculated 0.0519 0.0676    
SPLIT MSE 0.7149 0.0000 5.0000 1.0000 Calculated from schedules 0.0519 0.7149 1.0000 1.0000 Not calculated 0.0519 0.0726    
SPLIT MNE 0.7043 0.0000 5.0000 1.0000 Calculated from schedules 0.0519 0.7043 1.0000 1.0000 Not calculated 0.0519 0.0737    
SPLIT MN1 0.6039 0.0000 5.0000 1.0000 Calculated from schedules 0.0519 0.6039 1.0000 1.0000 Not calculated 0.0519 0.0860    
SPLIT MN2 0.6028 0.0000 5.0000 1.0000 Calculated from schedules 0.0519 0.6028 1.0000 1.0000 Not calculated 0.0519 0.0861    
SPLIT MS1 0.6142 0.0000 5.0000 1.0000 Calculated from schedules 0.0519 0.6142 1.0000 1.0000 Not calculated 0.0519 0.0845    
SPLIT MS2 0.6132 0.0000 5.0000 1.0000 Calculated from schedules 0.0519 0.6132 1.0000 1.0000 Not calculated 0.0519 0.0847    
SPLIT TSW 0.4499 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.4499 1.0000 1.0000 Not calculated 0.0260 0.0577    
SPLIT TNW 0.4489 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.4489 1.0000 1.0000 Not calculated 0.0260 0.0578    
SPLIT TSE 0.4031 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.4031 1.0000 1.0000 Not calculated 0.0260 0.0644    
SPLIT TNE 0.4020 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.4020 1.0000 1.0000 Not calculated 0.0260 0.0646    
SPLIT TN1 0.3611 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.3611 1.0000 1.0000 Not calculated 0.0260 0.0719    
SPLIT TN2 0.3596 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.3596 1.0000 1.0000 Not calculated 0.0260 0.0722    
SPLIT TS1 0.3629 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.3629 1.0000 1.0000 Not calculated 0.0260 0.0715    
SPLIT TS2 0.3614 0.0000 2.5000 1.0000 Calculated from schedules 0.0260 0.3614 1.0000 1.0000 Not calculated 0.0260 0.0718    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
G SW APARTMENT SPLIT GSW 0.000000 2.5000 0.000294 88.25 0.0260 1.0000 0.0260 1.000 0.0260
G NW APARTMENT SPLIT GNW 0.000000 2.5000 0.000294 88.25 0.0260 1.0000 0.0260 1.000 0.0260
OFFICE SPLIT OFFICE 0.000000 4.7495 0.000432 88.25 0.0381 1.0000 0.0381 1.000 0.0381
G NE APARTMENT SPLIT GNE 0.000000 2.5000 0.000294 88.25 0.0260 1.0000 0.0260 1.000 0.0260
G N1 APARTMENT SPLIT GN1 0.000000 2.5000 0.000294 88.25 0.0260 1.0000 0.0260 1.000 0.0260
G N2 APARTMENT SPLIT GN2 0.000000 2.5000 0.000294 88.25 0.0260 1.0000 0.0260 1.000 0.0260
G S1 APARTMENT SPLIT GS1 0.000000 2.5000 0.000294 88.25 0.0260 1.0000 0.0260 1.000 0.0260
G S2 APARTMENT SPLIT GS2 0.000000 2.5000 0.000294 88.25 0.0260 1.0000 0.0260 1.000 0.0260
M SW APARTMENT SPLIT MSW 0.000000 5.0000 0.000294 176.50 0.0519 1.0000 0.0519 1.000 0.0519
M NW APARTMENT SPLIT MNW 0.000000 5.0000 0.000294 176.50 0.0519 1.0000 0.0519 1.000 0.0519
M SE APARTMENT SPLIT MSE 0.000000 5.0000 0.000294 176.50 0.0519 1.0000 0.0519 1.000 0.0519
M NE APARTMENT SPLIT MNE 0.000000 5.0000 0.000294 176.50 0.0519 1.0000 0.0519 1.000 0.0519
M N1 APARTMENT SPLIT MN1 0.000000 5.0000 0.000294 176.50 0.0519 1.0000 0.0519 1.000 0.0519
M N2 APARTMENT SPLIT MN2 0.000000 5.0000 0.000294 176.50 0.0519 1.0000 0.0519 1.000 0.0519
M S1 APARTMENT SPLIT MS1 0.000000 5.0000 0.000294 176.50 0.0519 1.0000 0.0519 1.000 0.0519
M S2 APARTMENT SPLIT MS2 0.000000 5.0000 0.000294 176.50 0.0519 1.0000 0.0519 1.000 0.0519
T SW APARTMENT SPLIT TSW 0.000000 2.5000 0.000294 88.25 0.0260 1.0000 0.0260 1.000 0.0260
T NW APARTMENT SPLIT TNW 0.000000 2.5000 0.000294 88.25 0.0260 1.0000 0.0260 1.000 0.0260
T SE APARTMENT SPLIT TSE 0.000000 2.5000 0.000294 88.25 0.0260 1.0000 0.0260 1.000 0.0260
T NE APARTMENT SPLIT TNE 0.000000 2.5000 0.000294 88.25 0.0260 1.0000 0.0260 1.000 0.0260
T N1 APARTMENT SPLIT TN1 0.000000 2.5000 0.000294 88.25 0.0260 1.0000 0.0260 1.000 0.0260
T N2 APARTMENT SPLIT TN2 0.000000 2.5000 0.000294 88.25 0.0260 1.0000 0.0260 1.000 0.0260
T S1 APARTMENT SPLIT TS1 0.000000 2.5000 0.000294 88.25 0.0260 1.0000 0.0260 1.000 0.0260
T S2 APARTMENT SPLIT TS2 0.000000 2.5000 0.000294 88.25 0.0260 1.0000 0.0260 1.000 0.0260


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
SPLIT GSW 0.000000 2.50 0.000294 88.2493 0.0260 0.0260 0.0260
SPLIT GNW 0.000000 2.50 0.000294 88.2493 0.0260 0.0260 0.0260
SPLIT OFFICE 0.000000 4.75 0.000432 88.2493 0.0381 0.0381 0.0381
SPLIT GNE 0.000000 2.50 0.000294 88.2493 0.0260 0.0260 0.0260
SPLIT GN1 0.000000 2.50 0.000294 88.2493 0.0260 0.0260 0.0260
SPLIT GN2 0.000000 2.50 0.000294 88.2493 0.0260 0.0260 0.0260
SPLIT GS1 0.000000 2.50 0.000294 88.2493 0.0260 0.0260 0.0260
SPLIT GS2 0.000000 2.50 0.000294 88.2493 0.0260 0.0260 0.0260
SPLIT MSW 0.000000 5.00 0.000294 176.4985 0.0519 0.0519 0.0519
SPLIT MNW 0.000000 5.00 0.000294 176.4985 0.0519 0.0519 0.0519
SPLIT MSE 0.000000 5.00 0.000294 176.4985 0.0519 0.0519 0.0519
SPLIT MNE 0.000000 5.00 0.000294 176.4985 0.0519 0.0519 0.0519
SPLIT MN1 0.000000 5.00 0.000294 176.4985 0.0519 0.0519 0.0519
SPLIT MN2 0.000000 5.00 0.000294 176.4985 0.0519 0.0519 0.0519
SPLIT MS1 0.000000 5.00 0.000294 176.4985 0.0519 0.0519 0.0519
SPLIT MS2 0.000000 5.00 0.000294 176.4985 0.0519 0.0519 0.0519
SPLIT TSW 0.000000 2.50 0.000294 88.2493 0.0260 0.0260 0.0260
SPLIT TNW 0.000000 2.50 0.000294 88.2493 0.0260 0.0260 0.0260
SPLIT TSE 0.000000 2.50 0.000294 88.2493 0.0260 0.0260 0.0260
SPLIT TNE 0.000000 2.50 0.000294 88.2493 0.0260 0.0260 0.0260
SPLIT TN1 0.000000 2.50 0.000294 88.2493 0.0260 0.0260 0.0260
SPLIT TN2 0.000000 2.50 0.000294 88.2493 0.0260 0.0260 0.0260
SPLIT TS1 0.000000 2.50 0.000294 88.2493 0.0260 0.0260 0.0260
SPLIT TS2 0.000000 2.50 0.000294 88.2493 0.0260 0.0260 0.0260


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
G SW APARTMENT SPLIT GSW AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3419 0.3419 0.3419 No 0.0260 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
G NW APARTMENT SPLIT GNW AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3362 0.3362 0.3362 No 0.0260 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
OFFICE SPLIT OFFICE AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4090 0.4090 0.4090 No 0.0381 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
G NE APARTMENT SPLIT GNE AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3124 0.3124 0.3124 No 0.0260 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
G N1 APARTMENT SPLIT GN1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2679 0.2679 0.2679 No 0.0260 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
G N2 APARTMENT SPLIT GN2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2674 0.2674 0.2674 No 0.0260 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
G S1 APARTMENT SPLIT GS1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2732 0.2732 0.2732 No 0.0260 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
G S2 APARTMENT SPLIT GS2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2789 0.2789 0.2789 No 0.0260 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
M SW APARTMENT SPLIT MSW AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.7785 0.7785 0.7785 No 0.0519 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
M NW APARTMENT SPLIT MNW AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.7678 0.7678 0.7678 No 0.0519 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
M SE APARTMENT SPLIT MSE AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.7149 0.7149 0.7149 No 0.0519 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
M NE APARTMENT SPLIT MNE AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.7043 0.7043 0.7043 No 0.0519 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
M N1 APARTMENT SPLIT MN1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.6039 0.6039 0.6039 No 0.0519 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
M N2 APARTMENT SPLIT MN2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.6028 0.6028 0.6028 No 0.0519 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
M S1 APARTMENT SPLIT MS1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.6142 0.6142 0.6142 No 0.0519 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
M S2 APARTMENT SPLIT MS2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.6132 0.6132 0.6132 No 0.0519 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
T SW APARTMENT SPLIT TSW AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4499 0.4499 0.4499 No 0.0260 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
T NW APARTMENT SPLIT TNW AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4489 0.4489 0.4489 No 0.0260 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
T SE APARTMENT SPLIT TSE AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4031 0.4031 0.4031 No 0.0260 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
T NE APARTMENT SPLIT TNE AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4020 0.4020 0.4020 No 0.0260 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
T N1 APARTMENT SPLIT TN1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3611 0.3611 0.3611 No 0.0260 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
T N2 APARTMENT SPLIT TN2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3596 0.3596 0.3596 No 0.0260 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
T S1 APARTMENT SPLIT TS1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3629 0.3629 0.3629 No 0.0260 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
T S2 APARTMENT SPLIT TS2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3614 0.3614 0.3614 No 0.0260 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
SPLIT GSW 0.3419 0.3419 0.3419 0.3419 0.0260 1.0000
SPLIT GNW 0.3362 0.3362 0.3362 0.3362 0.0260 1.0000
SPLIT OFFICE 0.4090 0.4090 0.4090 0.4090 0.0381 1.0000
SPLIT GNE 0.3124 0.3124 0.3124 0.3124 0.0260 1.0000
SPLIT GN1 0.2679 0.2679 0.2679 0.2679 0.0260 1.0000
SPLIT GN2 0.2674 0.2674 0.2674 0.2674 0.0260 1.0000
SPLIT GS1 0.2732 0.2732 0.2732 0.2732 0.0260 1.0000
SPLIT GS2 0.2789 0.2789 0.2789 0.2789 0.0260 1.0000
SPLIT MSW 0.7785 0.7785 0.7785 0.7785 0.0519 1.0000
SPLIT MNW 0.7678 0.7678 0.7678 0.7678 0.0519 1.0000
SPLIT MSE 0.7149 0.7149 0.7149 0.7149 0.0519 1.0000
SPLIT MNE 0.7043 0.7043 0.7043 0.7043 0.0519 1.0000
SPLIT MN1 0.6039 0.6039 0.6039 0.6039 0.0519 1.0000
SPLIT MN2 0.6028 0.6028 0.6028 0.6028 0.0519 1.0000
SPLIT MS1 0.6142 0.6142 0.6142 0.6142 0.0519 1.0000
SPLIT MS2 0.6132 0.6132 0.6132 0.6132 0.0519 1.0000
SPLIT TSW 0.4499 0.4499 0.4499 0.4499 0.0260 1.0000
SPLIT TNW 0.4489 0.4489 0.4489 0.4489 0.0260 1.0000
SPLIT TSE 0.4031 0.4031 0.4031 0.4031 0.0260 1.0000
SPLIT TNE 0.4020 0.4020 0.4020 0.4020 0.0260 1.0000
SPLIT TN1 0.3611 0.3611 0.3611 0.3611 0.0260 1.0000
SPLIT TN2 0.3596 0.3596 0.3596 0.3596 0.0260 1.0000
SPLIT TS1 0.3629 0.3629 0.3629 0.3629 0.0260 1.0000
SPLIT TS2 0.3614 0.3614 0.3614 0.3614 0.0260 1.0000


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
G SW APARTMENT SPLIT GSW AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3419 0.3419 0.3419 No 0.0260 0.5704 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
G NW APARTMENT SPLIT GNW AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3362 0.3362 0.3362 No 0.0260 0.6775 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
OFFICE SPLIT OFFICE AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4090 0.4090 0.4090 No 0.0381 0.5443 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
G NE APARTMENT SPLIT GNE AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3124 0.3124 0.3124 No 0.0260 0.6753 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
G N1 APARTMENT SPLIT GN1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2679 0.2679 0.2679 No 0.0260 1.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
G N2 APARTMENT SPLIT GN2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2674 0.2674 0.2674 No 0.0260 1.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
G S1 APARTMENT SPLIT GS1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2732 0.2732 0.2732 No 0.0260 0.9865 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
G S2 APARTMENT SPLIT GS2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2789 0.2789 0.2789 No 0.0260 0.9622 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
M SW APARTMENT SPLIT MSW AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.7785 0.7785 0.7785 No 0.0519 0.5008 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
M NW APARTMENT SPLIT MNW AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.7678 0.7678 0.7678 No 0.0519 0.5955 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
M SE APARTMENT SPLIT MSE AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.7149 0.7149 0.7149 No 0.0519 0.4993 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
M NE APARTMENT SPLIT MNE AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.7043 0.7043 0.7043 No 0.0519 0.5934 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
M N1 APARTMENT SPLIT MN1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.6039 0.6039 0.6039 No 0.0519 1.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
M N2 APARTMENT SPLIT MN2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.6028 0.6028 0.6028 No 0.0519 1.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
M S1 APARTMENT SPLIT MS1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.6142 0.6142 0.6142 No 0.0519 0.9488 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
M S2 APARTMENT SPLIT MS2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.6132 0.6132 0.6132 No 0.0519 0.9487 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
T SW APARTMENT SPLIT TSW AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4499 0.4499 0.4499 No 0.0260 0.2798 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
T NW APARTMENT SPLIT TNW AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4489 0.4489 0.4489 No 0.0260 0.3093 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
T SE APARTMENT SPLIT TSE AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4031 0.4031 0.4031 No 0.0260 0.2792 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
T NE APARTMENT SPLIT TNE AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4020 0.4020 0.4020 No 0.0260 0.3087 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
T N1 APARTMENT SPLIT TN1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3611 0.3611 0.3611 No 0.0260 0.4542 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
T N2 APARTMENT SPLIT TN2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3596 0.3596 0.3596 No 0.0260 0.4542 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
T S1 APARTMENT SPLIT TS1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3629 0.3629 0.3629 No 0.0260 0.3930 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
T S2 APARTMENT SPLIT TS2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3614 0.3614 0.3614 No 0.0260 0.3930 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
SPLIT GSW 0.3419 0.3419 0.3419 0.3419 0.0260 1.0000
SPLIT GNW 0.3362 0.3362 0.3362 0.3362 0.0260 1.0000
SPLIT OFFICE 0.4090 0.4090 0.4090 0.4090 0.0381 1.0000
SPLIT GNE 0.3124 0.3124 0.3124 0.3124 0.0260 1.0000
SPLIT GN1 0.2679 0.2679 0.2679 0.2679 0.0260 1.0000
SPLIT GN2 0.2674 0.2674 0.2674 0.2674 0.0260 1.0000
SPLIT GS1 0.2732 0.2732 0.2732 0.2732 0.0260 1.0000
SPLIT GS2 0.2789 0.2789 0.2789 0.2789 0.0260 1.0000
SPLIT MSW 0.7785 0.7785 0.7785 0.7785 0.0519 1.0000
SPLIT MNW 0.7678 0.7678 0.7678 0.7678 0.0519 1.0000
SPLIT MSE 0.7149 0.7149 0.7149 0.7149 0.0519 1.0000
SPLIT MNE 0.7043 0.7043 0.7043 0.7043 0.0519 1.0000
SPLIT MN1 0.6039 0.6039 0.6039 0.6039 0.0519 1.0000
SPLIT MN2 0.6028 0.6028 0.6028 0.6028 0.0519 1.0000
SPLIT MS1 0.6142 0.6142 0.6142 0.6142 0.0519 1.0000
SPLIT MS2 0.6132 0.6132 0.6132 0.6132 0.0519 1.0000
SPLIT TSW 0.4499 0.4499 0.4499 0.4499 0.0260 1.0000
SPLIT TNW 0.4489 0.4489 0.4489 0.4489 0.0260 1.0000
SPLIT TSE 0.4031 0.4031 0.4031 0.4031 0.0260 1.0000
SPLIT TNE 0.4020 0.4020 0.4020 0.4020 0.0260 1.0000
SPLIT TN1 0.3611 0.3611 0.3611 0.3611 0.0260 1.0000
SPLIT TN2 0.3596 0.3596 0.3596 0.3596 0.0260 1.0000
SPLIT TS1 0.3629 0.3629 0.3629 0.3629 0.0260 1.0000
SPLIT TS2 0.3614 0.3614 0.3614 0.3614 0.0260 1.0000



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Sec1.1A-General Information

Data
Weather File RUNPERIOD 1 ** Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745
Total gross floor area [m2] 3134.61
Principal Heating Source Electricity


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 117.85
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 33.56
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 117.85
G S2 APARTMENT 88.25 88.25 0.00 117.85
M SW APARTMENT 88.25 88.25 0.00 117.85
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 117.85
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 117.85
M S2 APARTMENT 88.25 88.25 0.00 117.85
T SW APARTMENT 88.25 88.25 0.00 117.85
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 117.85
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 117.85
T S2 APARTMENT 88.25 88.25 0.00 117.85
T CORRIDOR 77.66 0.00 77.66 168.00
G CORRIDOR 77.66 0.00 77.66 168.00
M CORRIDOR 77.66 0.00 77.66 168.00
Totals 3134.61 2823.98 310.64  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 0.00
Number of hours cooling loads not met 0.00
Number of hours not met 0.00


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electricity Energy Use [GJ] Electricity Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Gasoline Use [GJ] Gasoline Demand [W] Diesel Use [GJ] Diesel Demand [W] Coal Use [GJ] Coal Demand [W] Fuel Oil No 1 Use [GJ] Fuel Oil No 1 Demand [W] Fuel Oil No 2 Use [GJ] Fuel Oil No 2 Demand [W] Propane Use [GJ] Propane Demand [W] Other Fuel 1 Use [GJ] Other Fuel 1 Demand [W] Other Fuel 2 Use [GJ] Other Fuel 2 Demand [W] District Cooling Use [GJ] District Cooling Demand [W] District Heating Use [GJ] District Heating Demand [W]
Heating -- General 1.82 4505.53 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling -- General 213.58 31651.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting -- LightsWired 49.34 2129.58 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting -- LightsPlugIn 4.52 431.87 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting -- General 22.83 1451.66 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment -- ElevatorLift 37.08 2318.63 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment -- ElevatorLightsFan 0.41 26.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment -- MiscPlug 386.12 18442.28 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans -- Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans -- General 120.13 10972.24 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps -- General 0.41 12.93 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- Water Heater 0.00 0.00 319.01 23106.97 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators -- DCtoACInverter Ancillary 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 423.60 836.23
Natural Gas 0.00 319.01
Additional 0.00 0.00
Total 423.60 1155.24


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 86.26
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting (All) 17.18
Space Heating 0.58
Space Cooling 68.14
Fans (All) 38.32
Service Water Heating 0.00
Receptacle Equipment 135.14
Miscellaneous (All) 266.77
Subtotal 266.77


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 0.00
Service Water Heating 101.77
Miscellaneous (All) 101.77
Subtotal 101.77


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Subtotal 0.00
Miscellaneous 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting (All) 4.66
Space Heating 0.16
Space Cooling 18.49
Fans (All) 10.40
Service Water Heating 27.61
Receptacle Equipment 36.67
Miscellaneous 2.01


Schedules-Equivalent Full Load Hours (Schedule Type=Fraction)

Equivalent Full Load Hours of Operation Per Year [hr] Hours > 1% [hr]
PV_SCH 8760. 8760.
ELEVATOR_RUNNING_SCH 146. 3285.
ELEVATOR_STANDBY_SCH 8201. 8760.
OCC_APT_SCH_STAY_HOME_FAMILY 5993. 8760.
OCC_APT_SCH_CORRIDOR 5993. 8760.
OCC_APT_SCH_WORKING_FAMILY 5845. 6055.
OCC_OFF_SCH 2210. 2340.
OCC_OFF_W_SB_SCH 1820. 1820.
LTG_SCH_OFFICE 2228. 8760.
LTG_SCH_CORRIDOR 5984. 8760.
LTG_SCH_APARTMENT_HARDWIRED 474. 8760.
LTG_SCH_APARTMENT_PLUGIN 474. 8760.
EQP_APT_SCH 5763. 8760.
EQP_OFF_SCH 3614. 8760.
INF_APT_SCH 8760. 8760.
INF_OFF_SCH 8760. 8760.
INF_COR_SCH 8760. 8760.
INFIL_DOOR_OPENING_SCH 1466. 5840.
ALL OFF 0. 0.
ALL ON 8760. 8760.
ALWAYS_ON 8760. 8760.
ALLON_EXCEPT_DD 8760. 8760.
EXTERIOR_LGT_ALWAYS_ON 8760. 8760.
FAN_OFF_W_SB_SCH 8240. 8240.
APT_DHW_SCH 4592. 8760.
EXTERIOR_LTG_SCH 4380. 4380.
ELEV_LIGHT_FAN_SCH_24_7 8760. 8760.
ELEV_LIGHT_FAN_SCH_ADD_DF 2154. 8760.
SLIDING_DOORS_VENTILATION_AVAILABILITY_SCH 5840. 5840.


Schedules-SetPoints (Schedule Type=Temperature)

First Object Used Month Assumed 11am First Wednesday [C] Days with Same 11am Value 11pm First Wednesday [C] Days with Same 11pm Value
HTGSETP_APT_SCH APTHEATINGSETPOINT January 21.10 365 21.10 365
HTGSETP_DESIGN_OFF_SCH OFFHEATINGSETPOINT January 21.10 365 21.10 365
CLGSETP_APT_SCH APTCOOLINGSETPOINT July 24.00 365 24.00 365
CLGSETP_DESIGN_OFF_SCH OFFCOOLINGSETPOINT July 23.90 365 23.90 365
S HTGSETP_APT_SCH S APARTMENT DUAL SP CONTROL January 15.54 365 21.10 365
S CLGSETP_APT_SCH S APARTMENT DUAL SP CONTROL July 26.78 365 24.00 365
N HTGSETP_APT_SCH N APARTMENT DUAL SP CONTROL January 21.10 365 21.10 365
N CLGSETP_APT_SCH N APARTMENT DUAL SP CONTROL July 24.00 365 24.00 365
HTGSETP_OFF_SCH_NO_OPTIMUM OFFICE DUAL SP CONTROL January 21.10 365 15.60 365
CLGSETP_OFF_SCH_NO_OPTIMUM OFFICE DUAL SP CONTROL July 24.00 365 29.40 365



Table of Contents

Report: Annual Thermal Resilience Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Heat Index Hours

Safe (≤ 26.7°C) [hr] Caution (> 26.7, ≤ 32.2°C) [hr] Extreme Caution (> 32.2, ≤ 39.4°C) [hr] Danger (> 39.4, ≤ 51.7°C) [hr] Extreme Danger (> 51.7°C) [hr]
G SW APARTMENT 8495.17 264.83 0.00 0.00 0.00
G NW APARTMENT 8759.33 0.67 0.00 0.00 0.00
OFFICE 6272.33 2487.67 0.00 0.00 0.00
G NE APARTMENT 8756.67 3.33 0.00 0.00 0.00
G N1 APARTMENT 8760.00 0.00 0.00 0.00 0.00
G N2 APARTMENT 8760.00 0.00 0.00 0.00 0.00
G S1 APARTMENT 8494.33 265.67 0.00 0.00 0.00
G S2 APARTMENT 8485.00 275.00 0.00 0.00 0.00
M SW APARTMENT 8520.33 239.67 0.00 0.00 0.00
M NW APARTMENT 8760.00 0.00 0.00 0.00 0.00
M SE APARTMENT 8500.67 259.33 0.00 0.00 0.00
M NE APARTMENT 8760.00 0.00 0.00 0.00 0.00
M N1 APARTMENT 8760.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 8760.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 8540.17 219.83 0.00 0.00 0.00
M S2 APARTMENT 8538.33 221.67 0.00 0.00 0.00
T SW APARTMENT 8506.83 253.17 0.00 0.00 0.00
T NW APARTMENT 8754.50 5.50 0.00 0.00 0.00
T SE APARTMENT 8506.83 253.17 0.00 0.00 0.00
T NE APARTMENT 8755.17 4.83 0.00 0.00 0.00
T N1 APARTMENT 8759.50 0.50 0.00 0.00 0.00
T N2 APARTMENT 8759.50 0.50 0.00 0.00 0.00
T S1 APARTMENT 8504.17 255.83 0.00 0.00 0.00
T S2 APARTMENT 8503.33 256.67 0.00 0.00 0.00
T CORRIDOR 4318.33 3370.83 1070.83 0.00 0.00
G CORRIDOR 5349.50 3384.33 26.17 0.00 0.00
M CORRIDOR 1796.00 6750.83 213.17 0.00 0.00
Min 1796.00 0.00 0.00 0.00 0.00
Max 8760.00 6750.83 1070.83 0.00 0.00
Average 8016.15 695.33 48.52 0.00 0.00
Sum 216436.00 18773.83 1310.17 0.00 0.00


Heat Index OccupantHours

Safe (≤ 26.7°C) [hr] Caution (> 26.7, ≤ 32.2°C) [hr] Extreme Caution (> 32.2, ≤ 39.4°C) [hr] Danger (> 39.4, ≤ 51.7°C) [hr] Extreme Danger (> 51.7°C) [hr]
G SW APARTMENT 11819.67 10.33 0.00 0.00 0.00
G NW APARTMENT 10584.67 0.33 0.00 0.00 0.00
OFFICE 7000.00 0.00 0.00 0.00 0.00
G NE APARTMENT 10584.33 0.67 0.00 0.00 0.00
G N1 APARTMENT 10585.00 0.00 0.00 0.00 0.00
G N2 APARTMENT 10585.00 0.00 0.00 0.00 0.00
G S1 APARTMENT 11808.67 21.33 0.00 0.00 0.00
G S2 APARTMENT 11802.83 27.17 0.00 0.00 0.00
M SW APARTMENT 11829.00 1.00 0.00 0.00 0.00
M NW APARTMENT 10585.00 0.00 0.00 0.00 0.00
M SE APARTMENT 11829.33 0.67 0.00 0.00 0.00
M NE APARTMENT 10585.00 0.00 0.00 0.00 0.00
M N1 APARTMENT 10585.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 10585.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 11830.00 0.00 0.00 0.00 0.00
M S2 APARTMENT 11830.00 0.00 0.00 0.00 0.00
T SW APARTMENT 11822.33 7.67 0.00 0.00 0.00
T NW APARTMENT 10577.83 7.17 0.00 0.00 0.00
T SE APARTMENT 11823.67 6.33 0.00 0.00 0.00
T NE APARTMENT 10583.00 2.00 0.00 0.00 0.00
T N1 APARTMENT 10584.00 1.00 0.00 0.00 0.00
T N2 APARTMENT 10584.00 1.00 0.00 0.00 0.00
T S1 APARTMENT 11828.33 1.67 0.00 0.00 0.00
T S2 APARTMENT 11828.17 1.83 0.00 0.00 0.00
T CORRIDOR 11680.17 8845.17 2469.67 0.00 0.00
G CORRIDOR 13659.00 9232.33 103.67 0.00 0.00
M CORRIDOR 4879.50 17649.17 466.33 0.00 0.00
Min 4879.50 0.00 0.00 0.00 0.00
Max 13659.00 17649.17 2469.67 0.00 0.00
Average 10899.20 1326.55 112.58 0.00 0.00
Sum 294278.50 35816.83 3039.67 0.00 0.00


Humidex Hours

Little to no Discomfort (≤ 29) [hr] Some Discomfort (> 29, ≤ 40) [hr] Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] Dangerous (> 45, ≤ 50) [hr] Heat Stroke Quite Possible (> 50) [hr]
G SW APARTMENT 8383.00 377.00 0.00 0.00 0.00
G NW APARTMENT 8647.00 113.00 0.00 0.00 0.00
OFFICE 7341.67 1418.33 0.00 0.00 0.00
G NE APARTMENT 8650.83 109.17 0.00 0.00 0.00
G N1 APARTMENT 8654.17 105.83 0.00 0.00 0.00
G N2 APARTMENT 8654.17 105.83 0.00 0.00 0.00
G S1 APARTMENT 8379.00 381.00 0.00 0.00 0.00
G S2 APARTMENT 8381.00 379.00 0.00 0.00 0.00
M SW APARTMENT 8385.67 374.33 0.00 0.00 0.00
M NW APARTMENT 8654.83 105.17 0.00 0.00 0.00
M SE APARTMENT 8382.83 377.17 0.00 0.00 0.00
M NE APARTMENT 8655.67 104.33 0.00 0.00 0.00
M N1 APARTMENT 8660.00 100.00 0.00 0.00 0.00
M N2 APARTMENT 8659.83 100.17 0.00 0.00 0.00
M S1 APARTMENT 8385.83 374.17 0.00 0.00 0.00
M S2 APARTMENT 8385.50 374.50 0.00 0.00 0.00
T SW APARTMENT 8383.83 376.17 0.00 0.00 0.00
T NW APARTMENT 8648.33 111.67 0.00 0.00 0.00
T SE APARTMENT 8387.17 372.83 0.00 0.00 0.00
T NE APARTMENT 8651.67 108.33 0.00 0.00 0.00
T N1 APARTMENT 8652.00 108.00 0.00 0.00 0.00
T N2 APARTMENT 8651.50 108.50 0.00 0.00 0.00
T S1 APARTMENT 8380.67 379.33 0.00 0.00 0.00
T S2 APARTMENT 8380.33 379.67 0.00 0.00 0.00
T CORRIDOR 64.67 6797.50 1897.83 0.00 0.00
G CORRIDOR 5994.17 2739.17 26.67 0.00 0.00
M CORRIDOR 0.00 6174.83 2585.17 0.00 0.00
Min 0.00 100.00 0.00 0.00 0.00
Max 8660.00 6797.50 2585.17 0.00 0.00
Average 7757.60 835.37 167.02 0.00 0.00
Sum 209455.33 22555.00 4509.67 0.00 0.00


Humidex OccupantHours

Little to no Discomfort (≤ 29) [hr] Some Discomfort (> 29, ≤ 40) [hr] Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] Dangerous (> 45, ≤ 50) [hr] Heat Stroke Quite Possible (> 50) [hr]
G SW APARTMENT 11677.67 152.33 0.00 0.00 0.00
G NW APARTMENT 10481.50 103.50 0.00 0.00 0.00
OFFICE 7000.00 0.00 0.00 0.00 0.00
G NE APARTMENT 10487.50 97.50 0.00 0.00 0.00
G N1 APARTMENT 10489.00 96.00 0.00 0.00 0.00
G N2 APARTMENT 10489.00 96.00 0.00 0.00 0.00
G S1 APARTMENT 11676.00 154.00 0.00 0.00 0.00
G S2 APARTMENT 11674.17 155.83 0.00 0.00 0.00
M SW APARTMENT 11688.17 141.83 0.00 0.00 0.00
M NW APARTMENT 10487.83 97.17 0.00 0.00 0.00
M SE APARTMENT 11682.00 148.00 0.00 0.00 0.00
M NE APARTMENT 10487.50 97.50 0.00 0.00 0.00
M N1 APARTMENT 10492.67 92.33 0.00 0.00 0.00
M N2 APARTMENT 10492.67 92.33 0.00 0.00 0.00
M S1 APARTMENT 11685.00 145.00 0.00 0.00 0.00
M S2 APARTMENT 11684.67 145.33 0.00 0.00 0.00
T SW APARTMENT 11673.00 157.00 0.00 0.00 0.00
T NW APARTMENT 10465.83 119.17 0.00 0.00 0.00
T SE APARTMENT 11668.17 161.83 0.00 0.00 0.00
T NE APARTMENT 10468.83 116.17 0.00 0.00 0.00
T N1 APARTMENT 10474.17 110.83 0.00 0.00 0.00
T N2 APARTMENT 10473.17 111.83 0.00 0.00 0.00
T S1 APARTMENT 11673.50 156.50 0.00 0.00 0.00
T S2 APARTMENT 11673.17 156.83 0.00 0.00 0.00
T CORRIDOR 159.67 18020.83 4814.50 0.00 0.00
G CORRIDOR 14750.67 8137.67 106.67 0.00 0.00
M CORRIDOR 0.00 16832.17 6162.83 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00
Max 14750.67 18020.83 6162.83 0.00 0.00
Average 10227.98 1699.83 410.52 0.00 0.00
Sum 276155.50 45895.50 11084.00 0.00 0.00


Heating SET Hours

SET ≤ 12.2°C Hours (°C) SET ≤ 12.2°C OccupantHours (°C) Longest SET ≤ 12.2°C Duration [hr] Start Time of the Longest SET ≤ 12.2°C Duration
None        


Cooling SET Hours

SET > 30°C Hours (°C) SET > 30°C OccupantHours (°C) Longest SET > 30°C Duration [hr] Start Time of the Longest SET > 30°C Duration
None        



Table of Contents

Report: Annual CO2 Resilience Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

CO2 Level Hours

Safe (<= 1000 ppm) [hr] Caution (> 1000, <= 5000 ppm) [hr] Hazard (> 5000 ppm) [hr]
None      


CO2 Level OccupantHours

Safe (<= 1000 ppm) [hr] Caution (> 1000, <= 5000 ppm) [hr] Hazard (> 5000 ppm) [hr]
None      



Table of Contents

Report: Annual Visual Resilience Summary

For: Entire Facility

Timestamp: 2024-07-03 12:27:39

Illuminance Level Hours

A Bit Dark (<= 100 lux) [hr] Dim (> 100, <= 300 lux) [hr] Adequate (> 300, <= 500 lux) [hr] Bright (>500 lux) [hr]
None        


Illuminance Level OccupantHours

A Bit Dark (<= 100 lux) [hr] Dim (> 100, <= 300 lux) [hr] Adequate (> 300, <= 500 lux) [hr] Bright (>500 lux) [hr]
None        



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 2B

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 14.827
February 12.716
March 15.425
April 23.310
May 26.312
June 31.196
July 30.423
August 29.815
September 27.754
October 20.869
November 15.431
December 11.863
   
Annual Sum or Average 21.705
Minimum of Months 11.863
Maximum of Months 31.196



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 14.827
February 12.716
March 15.425
April 23.310
May 26.312
June 31.196
July 30.423
August 29.815
September 27.754
October 20.869
November 15.431
December 11.863
   
Annual Sum or Average 21.705
Minimum of Months 11.863
Maximum of Months 31.196



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 14.827
February 12.716
March 15.425
April 23.310
May 26.312
June 31.196
July 30.423
August 29.815
September 27.754
October 20.869
November 15.431
December 11.863
   
Annual Sum or Average 21.705
Minimum of Months 11.863
Maximum of Months 31.196



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2022

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 14.827
February 12.716
March 15.425
April 23.310
May 26.312
June 31.196
July 30.423
August 29.815
September 27.754
October 20.869
November 15.431
December 11.863
   
Annual Sum or Average 21.705
Minimum of Months 11.863
Maximum of Months 31.196



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME APARTMENTMIDRISE

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 14.827
February 12.716
March 15.425
April 23.310
May 26.312
June 31.196
July 30.423
August 29.815
September 27.754
October 20.869
November 15.431
December 11.863
   
Annual Sum or Average 21.705
Minimum of Months 11.863
Maximum of Months 31.196



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_AZ_TUCSON

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 14.827
February 12.716
March 15.425
April 23.310
May 26.312
June 31.196
July 30.423
August 29.815
September 27.754
October 20.869
November 15.431
December 11.863
   
Annual Sum or Average 21.705
Minimum of Months 11.863
Maximum of Months 31.196



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 14.827
February 12.716
March 15.425
April 23.310
May 26.312
June 31.196
July 30.423
August 29.815
September 27.754
October 20.869
November 15.431
December 11.863
   
Annual Sum or Average 21.705
Minimum of Months 11.863
Maximum of Months 31.196



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PERFORMANCEPATHPROPOSED

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 14.827
February 12.716
March 15.425
April 23.310
May 26.312
June 31.196
July 30.423
August 29.815
September 27.754
October 20.869
November 15.431
December 11.863
   
Annual Sum or Average 21.705
Minimum of Months 11.863
Maximum of Months 31.196



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 14.827
February 12.716
March 15.425
April 23.310
May 26.312
June 31.196
July 30.423
August 29.815
September 27.754
October 20.869
November 15.431
December 11.863
   
Annual Sum or Average 21.705
Minimum of Months 11.863
Maximum of Months 31.196



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: G SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.115656E+10 5064.37 09-JAN-17:01 17.83 10.32 0.135099E+09 104.23 07-JAN-16:30 17.83 10.32
February 0.400602E+09 5049.57 24-FEB-17:01 14.00 8.80 0.108793E+09 92.43 28-FEB-18:10 16.67 8.22
March 0.468694E+09 4940.49 24-MAR-16:01 14.40 8.85 0.120762E+09 94.63 23-MAR-17:49 14.40 8.85
April 0.179520E+10 4975.46 18-APR-06:01 14.50 8.56 0.127348E+09 104.47 06-APR-17:49 14.50 8.56
May 0.197792E+10 4827.78 11-MAY-07:32 23.67 12.25 0.127971E+09 92.23 20-MAY-07:00 26.00 10.88
June 0.280124E+10 4837.38 04-JUN-06:42 25.67 14.69 0.122766E+09 95.37 08-JUN-06:00 26.00 12.85
July 0.319791E+10 4781.84 06-JUL-06:52 25.00 14.43 0.130667E+09 96.28 04-JUL-07:19 25.00 14.43
August 0.328158E+10 4884.69 23-AUG-07:22 24.00 13.61 0.126941E+09 104.00 28-AUG-17:30 23.00 19.67
September 0.332563E+10 5032.43 20-SEP-06:01 24.30 14.83 0.128450E+09 101.28 10-SEP-21:10 24.30 14.83
October 0.248523E+10 5008.93 07-OCT-15:52 20.00 13.38 0.136095E+09 107.57 07-OCT-15:00 20.00 13.38
November 0.165300E+10 5113.97 17-NOV-17:01 15.67 9.97 0.132911E+09 108.30 04-NOV-15:00 15.67 9.97
December 0.114348E+10 5052.89 13-DEC-17:01 14.67 7.33 0.132647E+09 106.38 24-DEC-16:49 22.17 9.80
                     
Annual Sum or Average 0.236870E+11         0.153045E+10        
Minimum of Months 0.400602E+09 4781.84   14.00 7.33 0.108793E+09 92.23   14.40 8.22
Maximum of Months 0.332563E+10 5113.97   25.67 14.83 0.136095E+09 108.30   26.00 19.67



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: G NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.294412E+09 4571.61 26-JAN-14:42 24.00 10.75 0.119686E+09 79.24 28-JAN-21:10 13.67 5.37
February 0.204532E+09 2806.30 01-FEB-17:12 14.67 6.54 92550230.64 70.38 01-FEB-00:40 14.67 6.54
March 0.287983E+09 4753.08 17-MAR-21:52 20.50 11.82 0.112081E+09 81.61 18-MAR-20:10 20.22 10.80
April 0.145456E+10 4793.84 16-APR-21:32 21.33 11.48 0.127104E+09 93.68 26-APR-20:10 17.83 9.05
May 0.206674E+10 4717.55 11-MAY-08:62 24.33 12.54 0.130582E+09 88.70 13-MAY-21:00 22.00 7.76
June 0.309677E+10 4759.97 04-JUN-06:42 25.67 14.69 0.126700E+09 86.47 26-JUN-05:00 23.00 10.35
July 0.336629E+10 4666.85 06-JUL-07:12 26.33 14.72 0.129800E+09 85.67 05-JUL-05:40 26.33 14.72
August 0.327110E+10 4690.56 23-AUG-08:12 27.33 14.86 0.131166E+09 95.30 04-AUG-21:30 27.33 14.86
September 0.303100E+10 4933.36 20-SEP-06:01 24.30 14.83 0.128275E+09 100.89 10-SEP-20:19 24.30 14.83
October 0.173895E+10 4878.41 21-OCT-21:52 19.00 14.63 0.137402E+09 96.95 07-OCT-21:10 19.00 14.63
November 0.754218E+09 4914.49 15-NOV-20:12 13.67 12.27 0.131331E+09 95.69 02-NOV-20:10 13.67 12.27
December 0.349723E+09 4724.20 27-DEC-19:02 13.82 7.44 0.117390E+09 84.57 26-DEC-21:19 13.82 7.44
                     
Annual Sum or Average 0.199163E+11         0.148407E+10        
Minimum of Months 0.204532E+09 2806.30   13.67 6.54 92550230.64 70.38   13.67 5.37
Maximum of Months 0.336629E+10 4933.36   27.33 14.86 0.137402E+09 100.89   27.33 14.86



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: OFFICE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.115508E+10 6051.00 17-JAN-07:01 12.83 4.51 67189370.80 133.53 09-JAN-11:09 12.83 4.51
February 0.535071E+09 1831.68 01-FEB-14:00 16.00 7.74 63070306.12 133.52 14-FEB-13:39 18.67 13.28
March 0.644974E+09 5678.92 21-MAR-06:01 12.75 7.80 76024620.94 133.51 02-MAR-11:20 12.75 7.80
April 0.148798E+10 6268.73 17-APR-06:01 16.17 10.40 67287669.47 133.51 21-APR-12:09 26.17 9.55
May 0.177541E+10 6134.05 01-MAY-06:01 13.50 5.09 74016443.20 133.51 25-MAY-12:09 31.17 12.57
June 0.234151E+10 6169.21 12-JUN-06:01 21.53 11.06 74016515.63 133.52 30-JUN-08:09 31.33 19.62
July 0.238822E+10 6319.62 31-JUL-06:01 25.00 15.78 67291780.71 133.54 17-JUL-07:10 25.00 15.78
August 0.279549E+10 6458.17 21-AUG-06:01 23.50 16.29 77385313.51 133.54 01-AUG-07:49 23.50 16.29
September 0.249600E+10 6400.96 27-SEP-06:01 19.90 13.92 67291424.53 133.55 05-SEP-07:10 19.90 13.92
October 0.211763E+10 6468.82 10-OCT-06:01 16.50 11.11 70652863.46 133.53 03-OCT-08:09 16.50 11.11
November 0.156135E+10 6348.38 16-NOV-07:01 11.17 8.77 67286805.25 133.53 14-NOV-13:50 11.17 8.77
December 0.114073E+10 6255.40 26-DEC-07:01 8.00 2.80 66768587.43 133.52 13-DEC-10:00 8.00 2.80
                     
Annual Sum or Average 0.204394E+11         0.838282E+09        
Minimum of Months 0.535071E+09 1831.68   8.00 2.80 63070306.12 133.51   8.00 2.80
Maximum of Months 0.279549E+10 6468.82   25.00 16.29 77385313.51 133.55   31.33 19.62



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: G NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.278664E+09 4296.74 28-JAN-21:02 13.67 5.37 0.118878E+09 78.80 28-JAN-21:10 13.67 5.37
February 0.207077E+09 1242.61 01-FEB-17:12 14.67 6.54 93632952.41 70.33 01-FEB-00:30 14.67 6.54
March 0.288876E+09 4452.76 18-MAR-11:32 24.80 14.55 0.112790E+09 80.61 20-MAR-20:10 20.13 11.18
April 0.146076E+10 4524.62 18-APR-06:01 14.50 8.56 0.127304E+09 90.96 16-APR-21:19 14.50 8.56
May 0.210304E+10 4437.08 11-MAY-08:62 24.33 12.54 0.131088E+09 88.57 13-MAY-21:00 22.00 7.76
June 0.314239E+10 4450.63 04-JUN-06:42 25.67 14.69 0.126869E+09 87.73 19-JUN-05:00 23.00 10.71
July 0.348376E+10 4356.28 06-JUL-07:12 26.33 14.72 0.129871E+09 85.69 03-JUL-05:00 26.33 14.72
August 0.337807E+10 4385.51 23-AUG-08:12 27.33 14.86 0.131280E+09 95.03 04-AUG-21:30 27.33 14.86
September 0.308378E+10 4595.78 20-SEP-06:01 24.30 14.83 0.128413E+09 101.49 10-SEP-20:19 24.30 14.83
October 0.177113E+10 4566.13 21-OCT-21:52 19.00 14.63 0.137422E+09 96.55 11-OCT-20:10 19.00 14.63
November 0.722139E+09 4565.11 15-NOV-20:12 13.67 12.27 0.130293E+09 95.32 02-NOV-20:10 13.67 12.27
December 0.349062E+09 4397.25 27-DEC-19:02 13.82 7.44 0.117371E+09 82.02 26-DEC-21:40 13.82 7.44
                     
Annual Sum or Average 0.202687E+11         0.148521E+10        
Minimum of Months 0.207077E+09 1242.61   13.67 5.37 93632952.41 70.33   13.67 5.37
Maximum of Months 0.348376E+10 4595.78   27.33 14.86 0.137422E+09 101.49   27.33 14.86



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: G N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.346546E+09 3841.75 20-JAN-20:42 14.58 10.58 0.124516E+09 81.39 31-JAN-22:10 14.48 5.13
February 0.226599E+09 2309.28 01-FEB-17:12 14.67 6.54 0.103596E+09 70.33 01-FEB-03:09 14.67 6.54
March 0.327513E+09 3851.35 17-MAR-21:52 20.50 11.82 0.120438E+09 82.79 21-MAR-21:00 17.70 10.41
April 0.122982E+10 3946.08 18-APR-06:01 14.50 8.56 0.127058E+09 89.70 16-APR-21:19 14.50 8.56
May 0.173656E+10 3808.33 11-MAY-08:62 24.33 12.54 0.130803E+09 87.81 13-MAY-21:00 22.00 7.76
June 0.247075E+10 3833.36 04-JUN-06:42 25.67 14.69 0.126669E+09 86.43 19-JUN-05:00 23.00 10.71
July 0.273789E+10 3759.08 06-JUL-07:12 26.33 14.72 0.129770E+09 84.74 03-JUL-05:00 26.33 14.72
August 0.264274E+10 3774.16 23-AUG-08:12 27.33 14.86 0.131076E+09 93.70 04-AUG-21:30 27.33 14.86
September 0.247504E+10 3956.60 20-SEP-06:01 24.30 14.83 0.128067E+09 97.52 10-SEP-20:19 24.30 14.83
October 0.152445E+10 3951.22 21-OCT-21:52 19.00 14.63 0.136517E+09 95.07 11-OCT-20:10 19.00 14.63
November 0.774850E+09 3962.87 15-NOV-20:12 13.67 12.27 0.130926E+09 94.05 02-NOV-20:10 13.67 12.27
December 0.413039E+09 3827.58 27-DEC-19:02 13.82 7.44 0.124052E+09 84.45 26-DEC-21:40 13.82 7.44
                     
Annual Sum or Average 0.169058E+11         0.151349E+10        
Minimum of Months 0.226599E+09 2309.28   13.67 6.54 0.103596E+09 70.33   13.67 5.13
Maximum of Months 0.273789E+10 3962.87   27.33 14.86 0.136517E+09 97.52   27.33 14.86



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: G N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.346604E+09 3835.90 20-JAN-20:42 14.58 10.58 0.124444E+09 81.42 31-JAN-22:10 14.48 5.13
February 0.227365E+09 2307.65 01-FEB-17:12 14.67 6.54 0.103844E+09 70.34 18-FEB-21:19 13.67 12.88
March 0.329641E+09 3845.71 17-MAR-21:52 20.50 11.82 0.120630E+09 82.88 21-MAR-21:00 17.70 10.41
April 0.123549E+10 3940.28 18-APR-06:01 14.50 8.56 0.127077E+09 89.73 16-APR-21:19 14.50 8.56
May 0.174202E+10 3803.28 11-MAY-08:62 24.33 12.54 0.130813E+09 87.85 13-MAY-21:00 22.00 7.76
June 0.247372E+10 3827.68 04-JUN-06:42 25.67 14.69 0.126670E+09 86.48 19-JUN-05:00 23.00 10.71
July 0.274308E+10 3753.41 06-JUL-07:12 26.33 14.72 0.129771E+09 84.73 03-JUL-05:00 26.33 14.72
August 0.264795E+10 3768.46 23-AUG-08:12 27.33 14.86 0.131080E+09 93.73 05-AUG-21:10 27.33 14.86
September 0.247837E+10 3950.54 20-SEP-06:01 24.30 14.83 0.128070E+09 97.57 10-SEP-20:19 24.30 14.83
October 0.152948E+10 3945.45 21-OCT-21:52 19.00 14.63 0.136564E+09 95.15 11-OCT-20:10 19.00 14.63
November 0.771892E+09 3965.27 15-NOV-20:12 13.67 12.27 0.130852E+09 94.05 02-NOV-20:10 13.67 12.27
December 0.413806E+09 3821.46 27-DEC-19:02 13.82 7.44 0.124126E+09 84.34 26-DEC-21:40 13.82 7.44
                     
Annual Sum or Average 0.169394E+11         0.151394E+10        
Minimum of Months 0.227365E+09 2307.65   13.67 6.54 0.103844E+09 70.34   13.67 5.13
Maximum of Months 0.274308E+10 3965.27   27.33 14.86 0.136564E+09 97.57   27.33 14.86



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: G S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.142882E+10 4093.99 09-JAN-17:01 17.83 10.32 0.136376E+09 101.26 26-JAN-18:10 21.50 8.98
February 0.605470E+09 4092.25 24-FEB-17:01 14.00 8.80 0.115382E+09 92.43 28-FEB-18:10 16.67 8.22
March 0.621118E+09 4017.41 24-MAR-16:01 14.40 8.85 0.126419E+09 92.43 23-MAR-17:10 14.40 8.85
April 0.162037E+10 4035.72 18-APR-06:01 14.50 8.56 0.127645E+09 97.91 06-APR-17:49 14.50 8.56
May 0.169750E+10 3913.90 11-MAY-07:32 23.67 12.25 0.128274E+09 92.45 20-MAY-07:49 25.50 10.59
June 0.223067E+10 3908.22 04-JUN-06:42 25.67 14.69 0.122756E+09 94.65 08-JUN-06:00 26.00 12.85
July 0.262686E+10 3869.88 06-JUL-06:52 25.00 14.43 0.130641E+09 95.18 04-JUL-07:19 25.00 14.43
August 0.271347E+10 3947.32 23-AUG-07:22 24.00 13.61 0.126860E+09 102.25 28-AUG-17:30 23.00 19.67
September 0.282278E+10 4048.60 20-SEP-06:01 24.30 14.83 0.128301E+09 99.47 30-SEP-07:40 24.57 13.51
October 0.231810E+10 4028.91 11-OCT-16:01 21.83 11.84 0.136008E+09 103.82 07-OCT-15:00 21.83 11.84
November 0.175146E+10 4136.99 17-NOV-17:01 15.67 9.97 0.133052E+09 104.85 04-NOV-15:00 15.67 9.97
December 0.143959E+10 4085.53 13-DEC-17:01 14.67 7.33 0.134311E+09 101.96 24-DEC-16:49 22.17 9.80
                     
Annual Sum or Average 0.218762E+11         0.154602E+10        
Minimum of Months 0.605470E+09 3869.88   14.00 7.33 0.115382E+09 92.43   14.40 8.22
Maximum of Months 0.282278E+10 4136.99   25.67 14.83 0.136376E+09 104.85   26.00 19.67



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: G S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.142356E+10 4175.55 09-JAN-17:01 17.83 10.32 0.136302E+09 100.98 26-JAN-18:10 21.50 8.98
February 0.595370E+09 4172.58 24-FEB-17:01 14.00 8.80 0.115243E+09 92.43 03-FEB-18:10 14.00 8.80
March 0.629711E+09 4098.21 24-MAR-16:01 14.40 8.85 0.126394E+09 92.43 23-MAR-17:10 14.40 8.85
April 0.172652E+10 4122.41 18-APR-06:01 14.50 8.56 0.127850E+09 98.07 06-APR-17:49 14.50 8.56
May 0.184170E+10 3996.56 11-MAY-07:32 23.67 12.25 0.128550E+09 92.63 20-MAY-07:40 25.00 10.30
June 0.242847E+10 3994.24 04-JUN-06:42 25.67 14.69 0.122970E+09 95.95 08-JUN-06:00 26.00 12.85
July 0.287053E+10 3949.39 06-JUL-06:52 25.00 14.43 0.130769E+09 97.25 04-JUL-07:19 25.00 14.43
August 0.292884E+10 4028.44 23-AUG-07:22 24.00 13.61 0.127089E+09 103.53 28-AUG-17:30 23.00 19.67
September 0.303419E+10 4135.95 20-SEP-06:01 24.30 14.83 0.128673E+09 101.55 10-SEP-21:10 24.30 14.83
October 0.245137E+10 4121.93 07-OCT-15:52 20.00 13.38 0.136348E+09 105.48 07-OCT-15:00 20.00 13.38
November 0.177386E+10 4218.63 17-NOV-17:01 15.67 9.97 0.133207E+09 105.36 04-NOV-15:00 15.67 9.97
December 0.142707E+10 4165.21 13-DEC-17:01 14.67 7.33 0.134282E+09 102.38 24-DEC-16:49 22.17 9.80
                     
Annual Sum or Average 0.231312E+11         0.154768E+10        
Minimum of Months 0.595370E+09 3949.39   14.00 7.33 0.115243E+09 92.43   14.00 8.56
Maximum of Months 0.303419E+10 4218.63   25.67 14.83 0.136348E+09 105.48   26.00 19.67



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: M SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.161694E+10 5742.47 09-JAN-17:01 17.83 10.32 0.136875E+09 111.26 07-JAN-16:30 17.83 10.32
February 0.884915E+09 5758.08 24-FEB-17:01 14.00 8.80 0.116638E+09 104.19 25-FEB-16:30 17.50 9.32
March 0.110503E+10 5665.84 11-MAR-18:52 14.40 11.25 0.131052E+09 105.93 31-MAR-17:49 21.88 8.23
April 0.249638E+10 5629.00 18-APR-06:01 14.50 8.56 0.128193E+09 110.92 06-APR-17:49 14.50 8.56
May 0.269298E+10 5455.88 11-MAY-07:32 23.67 12.25 0.128322E+09 92.48 06-MAY-08:09 23.67 12.25
June 0.334053E+10 5459.52 04-JUN-06:42 25.67 14.69 0.122717E+09 94.96 03-JUN-06:00 25.67 14.69
July 0.328240E+10 5405.98 12-JUL-16:01 32.83 19.75 0.130441E+09 92.74 01-JUL-07:40 32.83 19.75
August 0.320831E+10 5501.78 23-AUG-07:22 24.00 13.61 0.126349E+09 101.87 28-AUG-17:30 23.00 19.67
September 0.300344E+10 5668.16 20-SEP-06:01 24.30 14.83 0.127111E+09 97.00 21-SEP-19:30 23.25 16.46
October 0.226853E+10 5655.00 23-OCT-16:01 24.00 13.00 0.134945E+09 107.04 28-OCT-15:00 24.00 12.17
November 0.153648E+10 5783.47 17-NOV-17:01 15.67 9.97 0.131732E+09 108.05 05-NOV-16:40 15.67 9.97
December 0.118145E+10 5714.79 13-DEC-17:01 14.67 7.33 0.131758E+09 109.25 24-DEC-16:49 22.17 9.80
                     
Annual Sum or Average 0.266174E+11         0.154613E+10        
Minimum of Months 0.884915E+09 5405.98   14.00 7.33 0.116638E+09 92.48   14.50 8.23
Maximum of Months 0.334053E+10 5783.47   32.83 19.75 0.136875E+09 111.26   32.83 19.75



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: M NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.492678E+09 5436.06 09-JAN-20:02 13.50 10.12 0.127946E+09 89.09 07-JAN-21:10 13.50 10.12
February 0.334579E+09 5474.18 22-FEB-20:32 13.67 10.84 0.112238E+09 80.17 21-FEB-21:19 13.67 10.84
March 0.688463E+09 5552.70 11-MAR-18:52 14.40 11.25 0.131868E+09 93.51 23-MAR-20:10 15.92 7.66
April 0.212180E+10 5447.05 18-APR-06:01 14.50 8.56 0.128527E+09 97.36 20-APR-20:10 18.67 6.14
May 0.277741E+10 5356.97 11-MAY-08:62 24.33 12.54 0.130982E+09 91.34 13-MAY-21:00 22.00 7.76
June 0.361440E+10 5391.14 04-JUN-06:42 25.67 14.69 0.126682E+09 85.52 26-JUN-05:00 23.00 10.35
July 0.341205E+10 5283.35 06-JUL-07:12 26.33 14.72 0.129643E+09 83.31 15-JUL-05:00 24.00 21.09
August 0.313941E+10 5293.14 23-AUG-08:12 27.33 14.86 0.130707E+09 93.04 04-AUG-21:30 27.33 14.86
September 0.265635E+10 5580.59 20-SEP-06:01 24.30 14.83 0.127260E+09 94.87 10-SEP-20:19 24.30 14.83
October 0.145797E+10 5499.41 21-OCT-20:02 22.00 13.76 0.135013E+09 92.43 21-OCT-20:10 22.00 13.76
November 0.612517E+09 5532.32 15-NOV-20:12 13.67 12.27 0.127266E+09 91.46 02-NOV-20:10 13.67 12.27
December 0.337676E+09 5335.54 27-DEC-19:02 13.82 7.44 0.113974E+09 84.42 26-DEC-21:19 13.82 7.44
                     
Annual Sum or Average 0.216453E+11         0.152211E+10        
Minimum of Months 0.334579E+09 5283.35   13.50 7.44 0.112238E+09 80.17   13.50 6.14
Maximum of Months 0.361440E+10 5580.59   27.33 14.86 0.135013E+09 97.36   27.33 21.09



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: M SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.159222E+10 5283.55 09-JAN-17:01 17.83 10.32 0.136798E+09 105.63 07-JAN-16:30 17.83 10.32
February 0.924870E+09 5305.20 24-FEB-17:01 14.00 8.80 0.116829E+09 101.20 25-FEB-16:30 17.50 9.32
March 0.112917E+10 5246.91 11-MAR-18:52 14.40 11.25 0.130922E+09 101.72 18-MAR-09:00 22.70 14.66
April 0.249827E+10 5199.88 18-APR-06:01 14.50 8.56 0.128730E+09 104.66 06-APR-17:49 14.50 8.56
May 0.270148E+10 5065.35 11-MAY-07:32 23.67 12.25 0.129053E+09 101.83 13-MAY-09:30 23.00 10.84
June 0.335811E+10 5055.70 04-JUN-06:42 25.67 14.69 0.122975E+09 99.61 08-JUN-06:00 26.00 12.85
July 0.338303E+10 4994.30 06-JUL-06:52 25.00 14.43 0.130584E+09 99.17 01-JUL-07:40 25.00 14.43
August 0.329711E+10 5086.92 23-AUG-07:22 24.00 13.61 0.126506E+09 103.16 28-AUG-17:30 23.00 19.67
September 0.304699E+10 5223.93 20-SEP-06:01 24.30 14.83 0.127256E+09 97.17 16-SEP-08:20 24.30 14.83
October 0.230115E+10 5206.89 23-OCT-16:01 24.00 13.00 0.135134E+09 103.21 28-OCT-15:00 24.00 12.17
November 0.150549E+10 5326.45 17-NOV-17:01 15.67 9.97 0.131149E+09 104.93 20-NOV-18:19 21.33 11.19
December 0.118736E+10 5256.94 13-DEC-17:01 14.67 7.33 0.132014E+09 103.44 24-DEC-16:49 22.17 9.80
                     
Annual Sum or Average 0.269253E+11         0.154795E+10        
Minimum of Months 0.924870E+09 4994.30   14.00 7.33 0.116829E+09 97.17   14.50 8.56
Maximum of Months 0.338303E+10 5326.45   25.67 14.83 0.136798E+09 105.63   26.00 19.67



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: M NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.462553E+09 5004.17 09-JAN-20:02 13.50 10.12 0.126602E+09 83.86 25-JAN-21:19 14.33 7.14
February 0.363052E+09 5042.47 22-FEB-20:32 13.67 10.84 0.112543E+09 80.31 21-FEB-21:19 13.67 10.84
March 0.708801E+09 5081.43 11-MAR-18:52 14.40 11.25 0.131726E+09 90.94 23-MAR-20:10 15.92 7.66
April 0.212792E+10 5110.91 18-APR-06:01 14.50 8.56 0.128754E+09 95.73 20-APR-20:10 18.67 6.14
May 0.281656E+10 4971.89 11-MAY-08:62 24.33 12.54 0.131586E+09 91.09 13-MAY-21:00 22.00 7.76
June 0.366362E+10 4985.74 04-JUN-06:42 25.67 14.69 0.126900E+09 86.80 19-JUN-05:00 23.00 10.71
July 0.353890E+10 4877.99 06-JUL-07:12 26.33 14.72 0.129732E+09 83.65 15-JUL-05:00 24.00 21.09
August 0.325258E+10 4903.70 23-AUG-08:12 27.33 14.86 0.130837E+09 92.43 04-AUG-20:19 27.33 14.86
September 0.271069E+10 5137.24 20-SEP-06:01 24.30 14.83 0.127431E+09 95.30 10-SEP-20:19 24.30 14.83
October 0.148982E+10 5076.14 21-OCT-20:02 22.00 13.76 0.135054E+09 92.79 24-OCT-20:10 17.83 9.41
November 0.572213E+09 5084.32 15-NOV-20:12 13.67 12.27 0.126175E+09 91.19 02-NOV-20:10 13.67 12.27
December 0.334069E+09 4911.24 27-DEC-19:02 13.82 7.44 0.114043E+09 81.62 26-DEC-21:30 13.82 7.44
                     
Annual Sum or Average 0.220408E+11         0.152138E+10        
Minimum of Months 0.334069E+09 4877.99   13.50 7.44 0.112543E+09 80.31   13.67 6.14
Maximum of Months 0.366362E+10 5137.24   27.33 14.86 0.135054E+09 95.73   27.33 21.09



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: M N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.588885E+09 4361.10 09-JAN-20:02 13.50 10.12 0.130500E+09 86.23 07-JAN-22:49 13.50 10.12
February 0.495364E+09 4391.19 22-FEB-20:32 13.67 10.84 0.116457E+09 82.23 21-FEB-21:19 13.67 10.84
March 0.763057E+09 4432.24 11-MAR-18:52 14.40 11.25 0.133380E+09 89.97 17-MAR-20:10 20.68 13.00
April 0.167745E+10 4424.34 18-APR-06:01 14.50 8.56 0.127871E+09 91.00 16-APR-21:40 14.50 8.56
May 0.215813E+10 4269.72 11-MAY-08:62 24.33 12.54 0.131010E+09 89.03 13-MAY-21:00 22.00 7.76
June 0.271503E+10 4293.68 04-JUN-06:42 25.67 14.69 0.126576E+09 84.76 19-JUN-05:00 23.00 10.71
July 0.267395E+10 4203.83 06-JUL-07:12 26.33 14.72 0.129618E+09 82.74 15-JUL-05:00 24.00 21.09
August 0.246964E+10 4212.08 23-AUG-08:12 27.33 14.86 0.130659E+09 92.43 04-AUG-20:10 27.33 14.86
September 0.215983E+10 4420.30 20-SEP-06:01 24.30 14.83 0.127228E+09 92.43 10-SEP-20:40 24.30 14.83
October 0.130496E+10 4398.96 21-OCT-21:52 19.00 14.63 0.134252E+09 92.43 21-OCT-20:10 19.00 14.63
November 0.677597E+09 4430.65 15-NOV-20:12 13.67 12.27 0.128882E+09 89.19 02-NOV-21:00 13.67 12.27
December 0.428875E+09 4279.93 27-DEC-19:02 13.82 7.44 0.123511E+09 84.96 26-DEC-21:40 13.82 7.44
                     
Annual Sum or Average 0.181128E+11         0.153994E+10        
Minimum of Months 0.428875E+09 4203.83   13.50 7.44 0.116457E+09 82.23   13.50 7.44
Maximum of Months 0.271503E+10 4432.24   27.33 14.86 0.134252E+09 92.43   27.33 21.09



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: M N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.587302E+09 4353.34 09-JAN-20:02 13.50 10.12 0.130448E+09 85.96 07-JAN-22:49 13.50 10.12
February 0.499788E+09 4383.75 22-FEB-20:32 13.67 10.84 0.116497E+09 82.33 21-FEB-21:19 13.67 10.84
March 0.766859E+09 4423.46 11-MAR-18:52 14.40 11.25 0.133427E+09 89.91 17-MAR-20:10 20.68 13.00
April 0.168412E+10 4417.04 18-APR-06:01 14.50 8.56 0.127885E+09 91.12 16-APR-21:40 14.50 8.56
May 0.216455E+10 4263.26 11-MAY-08:62 24.33 12.54 0.131020E+09 89.07 13-MAY-21:00 22.00 7.76
June 0.271824E+10 4286.60 04-JUN-06:42 25.67 14.69 0.126577E+09 84.81 19-JUN-05:00 23.00 10.71
July 0.267899E+10 4196.71 06-JUL-07:12 26.33 14.72 0.129618E+09 82.73 15-JUL-05:00 24.00 21.09
August 0.247480E+10 4205.41 23-AUG-08:12 27.33 14.86 0.130662E+09 92.43 04-AUG-20:10 27.33 14.86
September 0.216357E+10 4412.65 20-SEP-06:01 24.30 14.83 0.127231E+09 92.43 10-SEP-20:40 24.30 14.83
October 0.130973E+10 4392.59 21-OCT-21:52 19.00 14.63 0.134271E+09 92.43 21-OCT-20:10 19.00 14.63
November 0.675869E+09 4421.81 15-NOV-20:12 13.67 12.27 0.128852E+09 89.20 02-NOV-21:00 13.67 12.27
December 0.430069E+09 4272.33 27-DEC-19:02 13.82 7.44 0.123611E+09 84.83 26-DEC-21:40 13.82 7.44
                     
Annual Sum or Average 0.181539E+11         0.154010E+10        
Minimum of Months 0.430069E+09 4196.71   13.50 7.44 0.116497E+09 82.33   13.50 7.44
Maximum of Months 0.271824E+10 4423.46   27.33 14.86 0.134271E+09 92.43   27.33 21.09



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: M S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.184194E+10 4584.89 09-JAN-17:01 17.83 10.32 0.137654E+09 105.65 07-JAN-16:30 17.83 10.32
February 0.117141E+10 4606.95 24-FEB-17:01 14.00 8.80 0.117712E+09 100.71 25-FEB-16:30 17.50 9.32
March 0.123658E+10 4566.25 11-MAR-18:52 14.40 11.25 0.131532E+09 99.97 10-MAR-18:30 14.40 11.25
April 0.208047E+10 4509.88 18-APR-06:01 14.50 8.56 0.128084E+09 102.43 06-APR-17:49 14.50 8.56
May 0.211342E+10 4370.50 11-MAY-07:32 23.67 12.25 0.128379E+09 92.45 06-MAY-08:20 23.67 12.25
June 0.248782E+10 4361.66 04-JUN-06:42 25.67 14.69 0.122607E+09 93.48 03-JUN-06:00 25.67 14.69
July 0.258837E+10 4321.26 06-JUL-06:52 25.00 14.43 0.130416E+09 92.43 01-JUL-07:00 25.00 14.43
August 0.258261E+10 4403.86 23-AUG-07:22 24.00 13.61 0.126330E+09 100.21 28-AUG-17:30 23.00 19.67
September 0.254138E+10 4511.50 20-SEP-06:01 24.30 14.83 0.127124E+09 95.83 21-SEP-20:49 22.28 16.70
October 0.216046E+10 4504.16 23-OCT-16:01 24.00 13.00 0.135043E+09 102.49 28-OCT-15:00 24.00 12.17
November 0.171017E+10 4623.74 17-NOV-17:01 15.67 9.97 0.132038E+09 104.60 20-NOV-18:19 21.33 11.19
December 0.154188E+10 4575.41 13-DEC-17:01 14.67 7.33 0.134334E+09 103.86 24-DEC-16:49 22.17 9.80
                     
Annual Sum or Average 0.240565E+11         0.155125E+10        
Minimum of Months 0.117141E+10 4321.26   14.00 7.33 0.117712E+09 92.43   14.40 8.56
Maximum of Months 0.258837E+10 4623.74   25.67 14.83 0.137654E+09 105.65   25.67 19.67



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: M S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.184385E+10 4577.99 09-JAN-17:01 17.83 10.32 0.137651E+09 105.60 07-JAN-16:30 17.83 10.32
February 0.117778E+10 4600.03 24-FEB-17:01 14.00 8.80 0.117723E+09 100.77 25-FEB-16:30 17.50 9.32
March 0.124332E+10 4558.68 11-MAR-18:52 14.40 11.25 0.131599E+09 99.93 10-MAR-18:30 14.40 11.25
April 0.208890E+10 4503.38 18-APR-06:01 14.50 8.56 0.128102E+09 102.37 06-APR-17:49 14.50 8.56
May 0.212165E+10 4364.54 11-MAY-07:32 23.67 12.25 0.128397E+09 92.46 06-MAY-08:09 23.67 12.25
June 0.249330E+10 4355.33 04-JUN-06:42 25.67 14.69 0.122610E+09 93.55 03-JUN-06:00 25.67 14.69
July 0.259528E+10 4314.92 06-JUL-06:52 25.00 14.43 0.130418E+09 92.43 06-JUL-06:00 25.00 14.43
August 0.258984E+10 4397.56 23-AUG-07:22 24.00 13.61 0.126336E+09 100.29 28-AUG-17:30 23.00 19.67
September 0.254626E+10 4504.68 20-SEP-06:01 24.30 14.83 0.127129E+09 95.85 21-SEP-20:49 22.28 16.70
October 0.216723E+10 4497.86 23-OCT-16:01 24.00 13.00 0.135056E+09 102.53 28-OCT-15:00 24.00 12.17
November 0.171064E+10 4616.84 17-NOV-17:01 15.67 9.97 0.132024E+09 104.57 20-NOV-18:19 21.33 11.19
December 0.154626E+10 4568.54 13-DEC-17:01 14.67 7.33 0.134346E+09 103.83 24-DEC-16:49 22.17 9.80
                     
Annual Sum or Average 0.241243E+11         0.155139E+10        
Minimum of Months 0.117778E+10 4314.92   14.00 7.33 0.117723E+09 92.43   14.40 8.56
Maximum of Months 0.259528E+10 4616.84   25.67 14.83 0.137651E+09 105.60   25.67 19.67



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: T SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.106363E+10 6592.01 09-JAN-17:01 17.83 10.32 0.121633E+09 118.58 07-JAN-16:19 17.83 10.32
February 0.452778E+09 6600.54 24-FEB-17:01 14.00 8.80 96131681.57 112.86 25-FEB-16:30 17.50 9.32
March 0.733834E+09 6464.88 02-MAR-17:01 19.22 11.35 0.117011E+09 115.75 31-MAR-17:49 21.88 8.23
April 0.250738E+10 6408.12 06-APR-16:01 23.83 11.06 0.125650E+09 117.04 06-APR-17:49 21.33 10.52
May 0.289807E+10 6170.86 11-MAY-07:32 23.67 12.25 0.126264E+09 92.43 13-MAY-21:00 22.00 7.76
June 0.388616E+10 6225.49 04-JUN-06:42 25.67 14.69 0.122005E+09 92.43 03-JUN-07:19 25.67 14.69
July 0.379349E+10 6263.74 12-JUL-16:01 32.83 19.75 0.130042E+09 92.35 09-JUL-07:49 32.83 19.75
August 0.364385E+10 6208.28 23-AUG-07:22 24.00 13.61 0.125831E+09 108.00 28-AUG-17:30 23.00 19.67
September 0.326085E+10 6489.89 20-SEP-06:01 24.30 14.83 0.126218E+09 101.23 10-SEP-21:10 24.30 14.83
October 0.204431E+10 6520.68 23-OCT-16:01 24.00 13.00 0.129380E+09 116.98 28-OCT-15:00 24.00 12.17
November 0.100834E+10 6632.98 17-NOV-17:01 15.67 9.97 0.118478E+09 117.02 04-NOV-15:00 15.67 9.97
December 0.634917E+09 6542.86 13-DEC-17:01 14.67 7.33 0.107983E+09 116.98 24-DEC-16:49 22.17 9.80
                     
Annual Sum or Average 0.259276E+11         0.144663E+10        
Minimum of Months 0.452778E+09 6170.86   14.00 7.33 96131681.57 92.35   15.67 7.76
Maximum of Months 0.388616E+10 6632.98   32.83 19.75 0.130042E+09 118.58   32.83 19.75



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: T NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.242470E+09 5288.78 07-JAN-22:52 18.00 11.23 0.105561E+09 88.56 07-JAN-21:10 18.00 11.23
February 0.135503E+09 5233.03 22-FEB-20:32 13.67 10.84 86305083.03 82.40 22-FEB-18:10 13.67 10.84
March 0.439775E+09 6360.35 11-MAR-18:52 14.40 11.25 0.114516E+09 100.51 23-MAR-20:10 15.92 7.66
April 0.214186E+10 6286.75 06-APR-17:32 21.67 10.57 0.126330E+09 107.52 26-APR-20:10 17.83 9.05
May 0.300131E+10 6171.90 11-MAY-08:62 24.33 12.54 0.129408E+09 92.41 13-MAY-21:00 22.00 7.76
June 0.420805E+10 6225.78 04-JUN-06:42 25.67 14.69 0.126234E+09 82.47 05-JUN-05:00 25.00 13.62
July 0.396872E+10 6097.15 06-JUL-07:12 26.33 14.72 0.129406E+09 82.42 15-JUL-05:00 24.00 21.09
August 0.359640E+10 6118.51 23-AUG-08:12 27.33 14.86 0.130451E+09 98.19 04-AUG-21:30 27.33 14.86
September 0.292348E+10 6441.45 20-SEP-06:01 24.30 14.83 0.126733E+09 103.35 10-SEP-20:19 24.30 14.83
October 0.129749E+10 6347.85 21-OCT-20:02 22.00 13.76 0.126242E+09 95.23 11-OCT-20:10 22.00 13.76
November 0.330598E+09 6368.26 15-NOV-20:12 13.67 12.27 0.107879E+09 93.61 02-NOV-20:10 13.67 12.27
December 0.112075E+09 2079.69 24-DEC-14:43 24.00 10.55 90978965.70 78.89 26-DEC-18:10 19.67 9.35
                     
Annual Sum or Average 0.223977E+11         0.140004E+10        
Minimum of Months 0.112075E+09 2079.69   13.67 10.55 86305083.03 78.89   13.67 7.66
Maximum of Months 0.420805E+10 6441.45   27.33 14.86 0.130451E+09 107.52   27.33 21.09



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: T SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.101054E+10 5933.43 09-JAN-17:01 17.83 10.32 0.121439E+09 115.30 07-JAN-16:30 17.83 10.32
February 0.454548E+09 5948.84 13-FEB-17:01 16.67 11.31 96660844.25 107.59 25-FEB-16:30 17.50 9.32
March 0.719956E+09 5840.11 11-MAR-18:52 14.40 11.25 0.116620E+09 105.89 18-MAR-09:00 22.70 14.66
April 0.248127E+10 5843.99 16-APR-10:52 22.00 12.76 0.126446E+09 111.72 06-APR-17:49 22.00 12.76
May 0.289286E+10 5673.40 13-MAY-09:42 23.67 10.67 0.127317E+09 108.73 13-MAY-09:30 23.67 10.67
June 0.390680E+10 5655.44 04-JUN-06:42 25.67 14.69 0.122377E+09 100.08 11-JUN-07:49 25.50 12.59
July 0.390587E+10 5644.66 12-JUL-16:01 32.83 19.75 0.130244E+09 95.56 04-JUL-07:19 32.83 19.75
August 0.373891E+10 5654.80 23-AUG-07:22 24.00 13.61 0.126013E+09 109.09 28-AUG-17:30 23.00 19.67
September 0.330337E+10 5845.14 20-SEP-06:01 24.30 14.83 0.126400E+09 101.21 04-SEP-09:09 24.30 14.83
October 0.205408E+10 5862.25 23-OCT-16:01 24.00 13.00 0.129611E+09 111.20 28-OCT-15:00 24.00 12.17
November 0.962794E+09 5966.19 17-NOV-17:01 15.67 9.97 0.117563E+09 111.04 04-NOV-15:00 15.67 9.97
December 0.607547E+09 5893.82 13-DEC-17:01 14.67 7.33 0.108349E+09 108.34 24-DEC-16:49 22.17 9.80
                     
Annual Sum or Average 0.260385E+11         0.144904E+10        
Minimum of Months 0.454548E+09 5644.66   14.40 7.33 96660844.25 95.56   15.67 9.32
Maximum of Months 0.390680E+10 5966.19   32.83 19.75 0.130244E+09 115.30   32.83 19.75



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: T NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.210811E+09 5406.79 26-JAN-14:42 24.00 10.75 0.103397E+09 76.78 07-JAN-22:49 24.00 10.75
February 0.140171E+09 2940.80 18-FEB-19:12 15.00 14.18 86146973.32 70.54 21-FEB-21:19 14.67 11.94
March 0.428210E+09 5699.89 18-MAR-11:32 24.80 14.55 0.113635E+09 93.84 16-MAR-20:40 24.80 14.55
April 0.212508E+10 5782.52 16-APR-12:02 23.17 13.09 0.126766E+09 101.04 20-APR-20:10 18.67 6.14
May 0.302755E+10 5728.34 13-MAY-10:12 24.33 10.56 0.130297E+09 91.02 13-MAY-21:00 22.00 7.76
June 0.426055E+10 5641.95 04-JUN-06:42 25.67 14.69 0.126560E+09 85.08 08-JUN-06:00 26.00 12.85
July 0.410423E+10 5516.98 06-JUL-07:12 26.33 14.72 0.129538E+09 82.84 15-JUL-05:00 24.00 21.09
August 0.371437E+10 5552.93 23-AUG-08:12 27.33 14.86 0.130620E+09 96.58 04-AUG-21:30 27.33 14.86
September 0.297539E+10 5797.08 20-SEP-06:01 24.30 14.83 0.126965E+09 103.06 10-SEP-20:19 24.30 14.83
October 0.129814E+10 5736.29 21-OCT-20:02 22.00 13.76 0.126629E+09 94.65 11-OCT-20:10 22.00 13.76
November 0.293852E+09 5738.68 01-NOV-19:52 21.00 13.76 0.105314E+09 92.64 02-NOV-20:10 20.83 15.78
December 0.106848E+09 2562.31 24-DEC-14:43 24.00 10.55 89708640.48 69.33 26-DEC-21:19 15.00 7.02
                     
Annual Sum or Average 0.226852E+11         0.139557E+10        
Minimum of Months 0.106848E+09 2562.31   15.00 10.55 86146973.32 69.33   14.67 6.14
Maximum of Months 0.426055E+10 5797.08   27.33 14.86 0.130620E+09 103.06   27.33 21.09



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: T N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.228033E+09 4473.96 07-JAN-22:52 18.00 11.23 0.108466E+09 81.07 07-JAN-22:49 18.00 11.23
February 0.169695E+09 3705.34 22-FEB-20:32 13.67 10.84 90455342.29 72.31 21-FEB-21:19 13.67 10.84
March 0.413438E+09 5155.20 17-MAR-21:52 20.50 11.82 0.117050E+09 94.54 23-MAR-20:10 15.92 7.66
April 0.165387E+10 5119.23 16-APR-21:32 21.33 11.48 0.126768E+09 99.33 20-APR-20:10 18.67 6.14
May 0.234375E+10 5054.07 11-MAY-08:62 24.33 12.54 0.129951E+09 90.48 13-MAY-21:00 22.00 7.76
June 0.326355E+10 5085.12 04-JUN-06:42 25.67 14.69 0.126295E+09 82.68 19-JUN-05:00 23.00 10.71
July 0.319947E+10 4978.55 06-JUL-07:12 26.33 14.72 0.129465E+09 82.35 15-JUL-05:00 24.00 21.09
August 0.289750E+10 4994.33 23-AUG-08:12 27.33 14.86 0.130531E+09 96.51 04-AUG-21:30 27.33 14.86
September 0.240341E+10 5230.64 20-SEP-06:01 24.30 14.83 0.126893E+09 100.65 10-SEP-20:19 24.30 14.83
October 0.107278E+10 5214.32 21-OCT-21:52 19.00 14.63 0.128000E+09 96.30 11-OCT-20:10 19.00 14.63
November 0.311477E+09 5199.68 01-NOV-19:52 21.00 13.76 0.110115E+09 93.36 02-NOV-21:10 20.00 15.60
December 0.136794E+09 1473.61 23-DEC-20:12 13.33 5.22 92881516.64 72.83 26-DEC-21:30 15.00 7.09
                     
Annual Sum or Average 0.180938E+11         0.141687E+10        
Minimum of Months 0.136794E+09 1473.61   13.33 5.22 90455342.29 72.31   13.67 6.14
Maximum of Months 0.326355E+10 5230.64   27.33 14.86 0.130531E+09 100.65   27.33 21.09



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: T N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.228335E+09 4730.35 28-JAN-14:42 24.00 8.85 0.108301E+09 80.29 07-JAN-22:49 24.00 8.85
February 0.170534E+09 3757.11 18-FEB-19:12 15.00 14.18 90574541.43 72.47 21-FEB-21:19 14.67 11.94
March 0.415670E+09 5140.99 18-MAR-11:32 24.80 14.55 0.117069E+09 94.00 23-MAR-20:10 15.92 7.66
April 0.166277E+10 5100.93 16-APR-12:22 23.50 12.97 0.126786E+09 99.39 20-APR-20:10 18.67 6.14
May 0.235201E+10 5036.60 11-MAY-08:62 24.33 12.54 0.129971E+09 90.45 13-MAY-21:00 22.00 7.76
June 0.326785E+10 5066.38 04-JUN-06:42 25.67 14.69 0.126296E+09 82.71 19-JUN-05:00 23.00 10.71
July 0.320580E+10 4959.74 06-JUL-07:12 26.33 14.72 0.129466E+09 82.33 15-JUL-05:00 24.00 21.09
August 0.290386E+10 4976.58 23-AUG-08:12 27.33 14.86 0.130534E+09 96.43 04-AUG-21:30 27.33 14.86
September 0.240800E+10 5210.23 20-SEP-06:01 24.30 14.83 0.126898E+09 100.65 10-SEP-20:19 24.30 14.83
October 0.107887E+10 5195.34 21-OCT-21:52 19.00 14.63 0.128345E+09 96.44 11-OCT-20:10 19.00 14.63
November 0.308635E+09 5180.11 01-NOV-19:52 21.00 13.76 0.109730E+09 93.34 02-NOV-21:10 20.00 15.60
December 0.136795E+09 1474.08 24-DEC-14:43 24.00 10.55 92799361.49 72.41 26-DEC-21:30 15.00 7.09
                     
Annual Sum or Average 0.181391E+11         0.141677E+10        
Minimum of Months 0.136795E+09 1474.08   15.00 8.85 90574541.43 72.41   14.67 6.14
Maximum of Months 0.326785E+10 5210.23   27.33 14.86 0.130534E+09 100.65   27.33 21.09



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: T S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.110086E+10 5388.03 09-JAN-17:01 17.83 10.32 0.128110E+09 116.14 07-JAN-16:30 17.83 10.32
February 0.519703E+09 5396.85 13-FEB-17:01 16.67 11.31 0.103842E+09 107.12 25-FEB-16:30 17.50 9.32
March 0.717424E+09 5314.75 11-MAR-18:52 14.40 11.25 0.121280E+09 104.33 12-MAR-15:50 16.52 9.68
April 0.204789E+10 5213.44 07-APR-16:01 24.00 11.76 0.126503E+09 110.29 06-APR-17:49 24.00 11.76
May 0.227311E+10 5066.80 11-MAY-07:32 23.67 12.25 0.126820E+09 91.66 13-MAY-09:50 23.67 10.67
June 0.297952E+10 5097.74 04-JUN-06:42 25.67 14.69 0.122071E+09 92.43 03-JUN-07:19 25.67 14.69
July 0.306053E+10 5077.06 12-JUL-16:01 32.83 19.75 0.130118E+09 92.42 09-JUL-07:49 32.83 19.75
August 0.298576E+10 5094.68 23-AUG-07:22 24.00 13.61 0.125931E+09 107.46 28-AUG-17:30 23.00 19.67
September 0.277560E+10 5289.29 20-SEP-06:01 24.30 14.83 0.126408E+09 99.73 10-SEP-21:10 24.30 14.83
October 0.186414E+10 5306.36 23-OCT-16:01 24.00 13.00 0.131803E+09 110.70 28-OCT-15:00 24.00 12.17
November 0.104257E+10 5420.57 17-NOV-17:01 15.67 9.97 0.123442E+09 112.07 04-NOV-15:00 15.67 9.97
December 0.727373E+09 5355.04 13-DEC-17:01 14.67 7.33 0.115332E+09 109.63 24-DEC-16:49 22.17 9.80
                     
Annual Sum or Average 0.220945E+11         0.148166E+10        
Minimum of Months 0.519703E+09 5066.80   14.40 7.33 0.103842E+09 91.66   15.67 9.32
Maximum of Months 0.306053E+10 5420.57   32.83 19.75 0.131803E+09 116.14   32.83 19.75



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: T S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.110576E+10 5368.21 09-JAN-17:01 17.83 10.32 0.128078E+09 115.98 07-JAN-16:30 17.83 10.32
February 0.527008E+09 5376.88 13-FEB-17:01 16.67 11.31 0.103937E+09 107.32 25-FEB-16:30 17.50 9.32
March 0.722997E+09 5294.54 11-MAR-18:52 14.40 11.25 0.121350E+09 104.26 12-MAR-15:50 16.52 9.68
April 0.205743E+10 5194.24 07-APR-16:01 24.00 11.76 0.126535E+09 109.99 06-APR-17:49 24.00 11.76
May 0.228271E+10 5052.44 13-MAY-09:42 23.67 10.67 0.126848E+09 92.41 13-MAY-09:50 23.67 10.67
June 0.298593E+10 5079.10 04-JUN-06:42 25.67 14.69 0.122076E+09 92.49 23-JUN-06:00 28.00 13.66
July 0.306859E+10 5057.93 12-JUL-16:01 32.83 19.75 0.130121E+09 92.42 09-JUL-07:49 32.83 19.75
August 0.299390E+10 5075.96 23-AUG-07:22 24.00 13.61 0.125935E+09 107.55 28-AUG-17:30 23.00 19.67
September 0.278116E+10 5269.02 20-SEP-06:01 24.30 14.83 0.126411E+09 99.73 10-SEP-21:10 24.30 14.83
October 0.187246E+10 5286.77 23-OCT-16:01 24.00 13.00 0.131827E+09 110.72 28-OCT-15:00 24.00 12.17
November 0.104543E+10 5400.11 17-NOV-17:01 15.67 9.97 0.123373E+09 112.12 04-NOV-15:00 15.67 9.97
December 0.731845E+09 5334.60 13-DEC-17:01 14.67 7.33 0.115377E+09 109.48 24-DEC-16:49 22.17 9.80
                     
Annual Sum or Average 0.221752E+11         0.148187E+10        
Minimum of Months 0.527008E+09 5052.44   14.40 7.33 0.103937E+09 92.41   15.67 9.32
Maximum of Months 0.306859E+10 5400.11   32.83 19.75 0.131827E+09 115.98   32.83 19.75



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: T CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:10 4.27 1.81 0.217188E+09 156.01 07-JAN-21:10 18.00 10.88
February 0.00 0.00 01-FEB-00:10 11.90 4.43 0.175993E+09 144.74 22-FEB-21:10 13.00 10.72
March 0.00 0.00 01-MAR-00:10 11.85 8.83 0.226272E+09 169.97 22-MAR-20:10 17.55 7.45
April 0.00 0.00 01-APR-00:10 15.28 7.34 0.268009E+09 176.09 14-APR-20:10 30.67 13.61
May 0.00 0.00 01-MAY-00:10 19.10 7.18 0.285454E+09 178.08 31-MAY-20:10 30.67 11.82
June 0.00 0.00 01-JUN-00:10 25.83 11.09 0.298544E+09 194.18 28-JUN-20:10 36.67 15.41
July 0.00 0.00 01-JUL-00:10 27.73 14.60 0.305207E+09 189.58 20-JUL-20:10 35.17 18.52
August 0.00 0.00 01-AUG-00:10 29.40 18.35 0.303047E+09 186.44 10-AUG-20:10 35.67 18.37
September 0.00 0.00 01-SEP-00:10 26.22 16.66 0.286230E+09 183.42 08-SEP-20:10 33.53 19.71
October 0.00 0.00 01-OCT-00:10 25.15 15.51 0.262143E+09 172.90 04-OCT-20:10 27.83 16.11
November 0.00 0.00 01-NOV-00:10 17.23 10.27 0.218932E+09 167.58 01-NOV-20:10 20.50 13.68
December 0.00 0.00 01-DEC-00:10 9.20 2.98 0.182179E+09 143.95 22-DEC-21:10 13.67 5.30
                     
Annual Sum or Average 0.00         0.302920E+10        
Minimum of Months 0.00 0.00   4.27 1.81 0.175993E+09 143.95   13.00 5.30
Maximum of Months 0.00 0.00   29.40 18.35 0.305207E+09 194.18   36.67 19.71



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: G CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:10 4.27 1.81 0.239708E+09 162.91 31-JAN-23:10 13.18 3.96
February 0.00 0.00 01-FEB-00:10 11.90 4.43 0.183780E+09 162.22 01-FEB-00:10 11.90 4.43
March 0.00 0.00 01-MAR-00:10 11.85 8.83 0.229740E+09 166.24 18-MAR-21:40 16.27 9.97
April 0.00 0.00 01-APR-00:10 15.28 7.34 0.300148E+09 225.73 14-APR-17:10 34.83 14.48
May 0.00 0.00 01-MAY-00:10 19.10 7.18 0.333517E+09 241.98 31-MAY-17:10 36.83 14.02
June 0.00 0.00 01-JUN-00:10 25.83 11.09 0.362339E+09 294.66 28-JUN-17:10 41.83 19.10
July 0.00 0.00 01-JUL-00:10 27.73 14.60 0.371223E+09 268.96 20-JUL-17:10 39.00 20.06
August 0.00 0.00 01-AUG-00:10 29.40 18.35 0.368536E+09 286.24 25-AUG-17:10 40.67 17.58
September 0.00 0.00 01-SEP-00:10 26.22 16.66 0.348049E+09 255.37 07-SEP-17:10 37.02 19.96
October 0.00 0.00 01-OCT-00:10 25.15 15.51 0.311949E+09 225.70 06-OCT-17:10 33.67 14.88
November 0.00 0.00 01-NOV-00:10 17.23 10.27 0.256753E+09 184.19 02-NOV-22:10 19.83 16.01
December 0.00 0.00 01-DEC-00:10 9.20 2.98 0.224824E+09 165.58 26-DEC-22:40 14.33 6.96
                     
Annual Sum or Average 0.00         0.353057E+10        
Minimum of Months 0.00 0.00   4.27 1.81 0.183780E+09 162.22   11.90 3.96
Maximum of Months 0.00 0.00   29.40 18.35 0.371223E+09 294.66   41.83 20.06



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: M CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:10 4.27 1.81 0.268693E+09 162.36 27-JAN-21:10 16.17 6.63
February 0.00 0.00 01-FEB-00:10 11.90 4.43 0.232597E+09 156.04 22-FEB-21:10 13.00 10.72
March 0.00 0.00 01-MAR-00:10 11.85 8.83 0.270550E+09 165.18 22-MAR-20:10 17.55 7.45
April 0.00 0.00 01-APR-00:10 15.28 7.34 0.279024E+09 169.09 06-APR-20:10 17.00 8.63
May 0.00 0.00 01-MAY-00:10 19.10 7.18 0.290667E+09 167.01 19-MAY-20:10 30.67 12.42
June 0.00 0.00 01-JUN-00:10 25.83 11.09 0.290254E+09 173.49 28-JUN-20:10 36.67 15.41
July 0.00 0.00 01-JUL-00:10 27.73 14.60 0.295093E+09 170.88 20-JUL-20:10 35.17 18.52
August 0.00 0.00 01-AUG-00:10 29.40 18.35 0.295628E+09 170.42 25-AUG-20:10 34.50 14.41
September 0.00 0.00 01-SEP-00:10 26.22 16.66 0.283503E+09 169.20 08-SEP-20:10 33.53 19.71
October 0.00 0.00 01-OCT-00:10 25.15 15.51 0.285570E+09 167.72 11-OCT-20:10 16.67 7.70
November 0.00 0.00 01-NOV-00:10 17.23 10.27 0.265481E+09 166.84 01-NOV-20:19 20.00 13.59
December 0.00 0.00 01-DEC-00:10 9.20 2.98 0.250956E+09 158.83 26-DEC-21:10 15.00 6.95
                     
Annual Sum or Average 0.00         0.330802E+10        
Minimum of Months 0.00 0.00   4.27 1.81 0.232597E+09 156.04   13.00 6.63
Maximum of Months 0.00 0.00   29.40 18.35 0.295628E+09 173.49   36.67 19.71



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: G SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 42956.04 41.67 14-JAN-12:35 25.00
February 5732.63 10.57 18-FEB-14:53 22.00
March 3133882.84 74.11 20-MAR-16:14 28.47
April 5960332.65 130.99 11-APR-16:06 33.83
May 15994717.45 154.58 16-MAY-16:06 35.85
June 11374084.60 144.39 12-JUN-16:06 35.00
July 6080140.35 94.76 10-JUL-09:40 33.33
August 4597715.75 111.28 29-AUG-16:06 31.83
September 1598750.97 70.35 07-SEP-08:62 29.27
October 573966.20 60.49 02-OCT-09:05 30.17
November 48153.53 41.46 11-NOV-13:05 24.78
December 30442.08 31.43 02-DEC-13:45 24.00
         
Annual Sum or Average 49440875.09      
Minimum of Months 5732.63 10.57   22.00
Maximum of Months 15994717.45 154.58   35.85



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: G NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 6643316.08 156.10 01-JAN-08:00 0.50
February 43203.32 6.11 18-FEB-14:05 22.00
March 2265398.54 55.95 14-MAR-14:00 27.20
April 2864407.60 83.86 01-APR-11:40 29.67
May 2079434.21 69.69 18-MAY-08:15 27.67
June 793232.32 78.49 23-JUN-07:05 28.17
July 219139.60 71.34 05-JUL-07:05 27.50
August 361736.65 71.29 24-AUG-08:25 27.50
September 593901.95 74.20 29-SEP-08:25 27.75
October 662509.00 69.28 06-OCT-08:45 27.33
November 534918.94 50.98 20-NOV-12:05 26.00
December 507780.78 46.17 25-DEC-13:14 25.33
         
Annual Sum or Average 17568979.00      
Minimum of Months 43203.32 6.11   0.50
Maximum of Months 6643316.08 156.10   29.67



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: OFFICE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.102090E+09 508.67 31-JAN-17:12 27.67
February 51441734.69 314.42 18-FEB-16:00 22.00
March 0.163640E+09 800.87 27-MAR-06:01 1.97
April 0.460601E+09 767.06 14-APR-16:13 35.00
May 0.586098E+09 845.10 31-MAY-16:13 37.00
June 0.577327E+09 1040.04 28-JUN-16:01 42.00
July 0.485203E+09 878.48 18-JUL-16:01 38.83
August 0.472960E+09 973.39 25-AUG-16:01 41.00
September 0.364579E+09 791.88 08-SEP-16:13 37.73
October 0.208660E+09 704.75 03-OCT-16:01 34.83
November 77546216.82 461.77 01-NOV-16:13 27.33
December 60084695.71 352.37 02-DEC-15:00 25.00
         
Annual Sum or Average 0.361023E+10      
Minimum of Months 51441734.69 314.42   1.97
Maximum of Months 0.586098E+09 1040.04   42.00



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: G NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 8496382.20 170.52 01-JAN-05:00 1.20
February 21125.07 3.25 18-FEB-14:05 22.00
March 1991333.71 54.84 14-MAR-14:23 26.65
April 1056415.59 62.40 13-APR-09:35 27.00
May 744974.70 69.39 18-MAY-08:15 27.67
June 579998.25 75.64 23-JUN-07:05 28.17
July 169833.72 69.52 05-JUL-07:05 27.50
August 256752.14 67.98 24-AUG-08:25 27.50
September 469547.78 72.97 29-SEP-08:25 27.75
October 457140.85 67.22 06-OCT-08:45 27.33
November 400303.50 53.42 20-NOV-12:05 26.00
December 447903.29 38.73 25-DEC-13:30 25.50
         
Annual Sum or Average 15091710.82      
Minimum of Months 21125.07 3.25   1.20
Maximum of Months 8496382.20 170.52   28.17



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: G N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 2504623.33 53.74 14-JAN-13:05 26.17
February 1061.19 0.69 18-FEB-14:05 22.00
March 1796601.00 56.97 14-MAR-14:23 26.65
April 2422699.51 63.14 13-APR-09:35 27.00
May 1927352.18 70.28 18-MAY-08:15 27.67
June 695708.83 61.48 02-JUN-07:15 27.00
July 178670.71 54.45 29-JUL-08:17 26.67
August 339342.64 61.46 30-AUG-08:15 27.33
September 508429.70 61.00 12-SEP-07:57 27.20
October 648744.68 57.43 10-OCT-09:05 26.50
November 625632.58 53.28 20-NOV-12:05 26.00
December 444410.03 39.43 25-DEC-13:16 25.33
         
Annual Sum or Average 12093276.36      
Minimum of Months 1061.19 0.69   22.00
Maximum of Months 2504623.33 70.28   27.67



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: G N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 2507235.09 53.82 14-JAN-13:05 26.17
February 235.86 0.39 18-FEB-14:05 22.00
March 1772315.38 57.18 14-MAR-14:23 26.65
April 2336203.29 63.38 13-APR-09:35 27.00
May 1893726.00 70.07 18-MAY-08:15 27.67
June 676230.49 61.40 02-JUN-07:15 27.00
July 173025.53 54.52 29-JUL-08:17 26.67
August 328454.82 61.45 30-AUG-08:15 27.33
September 511004.11 61.06 12-SEP-07:57 27.20
October 621465.12 57.29 10-OCT-09:05 26.50
November 620143.98 53.12 20-NOV-12:05 26.00
December 437415.94 39.60 25-DEC-13:16 25.33
         
Annual Sum or Average 11877455.61      
Minimum of Months 235.86 0.39   22.00
Maximum of Months 2507235.09 70.07   27.67



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: G S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 6998.10 29.86 26-JAN-17:06 24.50
February 1064.70 3.79 18-FEB-14:55 22.00
March 2820984.11 72.39 20-MAR-16:06 28.38
April 6347692.88 75.22 24-APR-12:20 31.67
May 21451089.34 101.62 30-MAY-15:00 34.00
June 18021627.72 118.61 28-JUN-08:62 33.33
July 11118634.13 113.41 10-JUL-10:30 35.00
August 6921987.74 96.67 14-AUG-09:30 33.50
September 1982710.65 71.50 07-SEP-08:62 29.27
October 577122.09 62.52 02-OCT-09:05 30.17
November 29452.87 37.89 11-NOV-13:05 24.78
December 8166.69 10.69 21-DEC-17:06 22.67
         
Annual Sum or Average 69287531.01      
Minimum of Months 1064.70 3.79   22.00
Maximum of Months 21451089.34 118.61   35.00



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: G S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 15170.29 31.08 26-JAN-17:06 24.50
February 1027.71 3.81 18-FEB-14:55 22.00
March 2775667.16 75.81 16-MAR-16:06 28.72
April 5018122.35 77.30 17-APR-16:06 28.83
May 17076239.09 93.68 15-MAY-12:20 33.33
June 13542503.44 118.15 28-JUN-08:62 33.33
July 7835253.54 98.47 10-JUL-09:50 33.67
August 5261690.32 92.71 15-AUG-08:62 31.17
September 1605705.51 84.37 11-SEP-16:08 29.50
October 504720.68 60.79 02-OCT-09:05 30.17
November 32644.97 38.13 11-NOV-13:05 24.78
December 9688.56 17.78 22-DEC-17:06 23.33
         
Annual Sum or Average 53678433.61      
Minimum of Months 1027.71 3.81   22.00
Maximum of Months 17076239.09 118.15   33.67



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: M SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 21016.67 38.54 14-JAN-12:35 25.00
February 852.85 8.53 18-FEB-14:55 22.00
March 724142.05 76.94 20-MAR-16:05 28.38
April 3269812.15 59.95 24-APR-11:20 30.33
May 9084286.78 113.85 25-MAY-16:05 31.83
June 11323264.96 117.24 28-JUN-08:62 33.33
July 11856803.87 117.09 10-JUL-10:40 35.33
August 9780870.68 102.30 08-AUG-10:00 34.00
September 4297588.85 76.39 18-SEP-09:40 31.80
October 1362430.25 68.22 02-OCT-10:00 31.00
November 54715.56 36.63 11-NOV-13:05 24.78
December 22356.27 28.52 02-DEC-13:45 24.00
         
Annual Sum or Average 51798140.95      
Minimum of Months 852.85 8.53   22.00
Maximum of Months 11856803.87 117.24   35.33



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: M NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 1378779.20 59.03 31-JAN-13:04 26.33
February 0.00 0.00 01-FEB-00:10 11.90
March 550576.95 55.67 14-MAR-14:25 26.65
April 1267034.51 59.35 13-APR-09:35 27.00
May 1407814.72 69.20 18-MAY-08:15 27.67
June 758774.91 76.18 23-JUN-07:05 28.17
July 401603.11 68.54 05-JUL-07:05 27.50
August 711315.06 67.07 24-AUG-08:25 27.50
September 1179732.80 68.72 29-SEP-08:25 27.75
October 1067652.81 62.89 06-OCT-08:45 27.33
November 802845.21 49.12 09-NOV-11:43 25.67
December 609744.54 49.21 25-DEC-13:14 25.33
         
Annual Sum or Average 10135873.82      
Minimum of Months 0.00 0.00   11.90
Maximum of Months 1407814.72 76.18   28.17



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: M SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 6227.84 14.96 16-JAN-11:15 22.67
February 1099.94 10.60 18-FEB-14:55 22.00
March 307919.97 75.29 20-MAR-16:05 28.38
April 612641.16 54.60 01-APR-09:45 26.50
May 1815828.09 63.04 17-MAY-07:55 27.00
June 3825902.29 114.77 28-JUN-08:62 33.33
July 4187572.18 92.07 11-JUL-08:62 31.17
August 3493769.33 90.61 15-AUG-08:62 31.17
September 2032577.13 70.16 07-SEP-08:62 29.27
October 501815.77 60.44 02-OCT-09:05 30.17
November 48976.76 38.49 11-NOV-13:05 24.78
December 13687.09 27.42 02-DEC-13:45 24.00
         
Annual Sum or Average 16848017.55      
Minimum of Months 1099.94 10.60   22.00
Maximum of Months 4187572.18 114.77   33.33



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: M NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 1131529.17 57.84 14-JAN-13:05 26.17
February 0.00 0.00 01-FEB-00:10 11.90
March 390077.85 59.45 14-MAR-14:25 26.65
April 590609.54 63.74 13-APR-09:35 27.00
May 655386.72 71.05 18-MAY-08:15 27.67
June 605187.85 77.07 23-JUN-07:05 28.17
July 230856.31 69.82 05-JUL-07:05 27.50
August 361904.38 69.45 24-AUG-08:25 27.50
September 675011.81 70.56 29-SEP-08:25 27.75
October 569237.44 67.83 06-OCT-08:45 27.33
November 622169.59 50.61 20-NOV-12:05 26.00
December 512838.84 45.65 25-DEC-13:14 25.33
         
Annual Sum or Average 6344809.51      
Minimum of Months 0.00 0.00   11.90
Maximum of Months 1131529.17 77.07   28.17



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: M N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 1113951.38 56.62 14-JAN-13:05 26.17
February 0.00 0.00 01-FEB-00:10 11.90
March 593936.22 58.73 14-MAR-14:25 26.65
April 1440896.90 62.18 13-APR-09:35 27.00
May 1524087.16 71.07 18-MAY-08:15 27.67
June 1144526.26 75.14 23-JUN-07:05 28.17
July 453404.14 68.29 05-JUL-07:05 27.50
August 722706.94 69.36 24-AUG-08:25 27.50
September 1207914.75 71.37 29-SEP-08:25 27.75
October 1163313.95 65.93 06-OCT-08:45 27.33
November 716422.85 48.98 20-NOV-12:05 26.00
December 435847.37 36.77 25-DEC-13:16 25.33
         
Annual Sum or Average 10517007.92      
Minimum of Months 0.00 0.00   11.90
Maximum of Months 1524087.16 75.14   28.17



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: M N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 1102516.91 56.49 14-JAN-13:05 26.17
February 0.00 0.00 01-FEB-00:10 11.90
March 584375.06 58.99 14-MAR-14:25 26.65
April 1422348.91 62.44 13-APR-09:35 27.00
May 1509394.70 70.86 18-MAY-08:15 27.67
June 1126156.36 75.09 23-JUN-07:05 28.17
July 438153.93 68.20 05-JUL-07:05 27.50
August 714016.54 69.51 24-AUG-08:25 27.50
September 1200057.29 71.40 29-SEP-08:25 27.75
October 1148053.25 66.11 06-OCT-08:45 27.33
November 709808.45 49.25 20-NOV-12:05 26.00
December 426379.81 36.98 25-DEC-13:16 25.33
         
Annual Sum or Average 10381261.21      
Minimum of Months 0.00 0.00   11.90
Maximum of Months 1509394.70 75.09   28.17



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: M S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 5686.34 14.51 16-JAN-11:15 22.67
February 962.14 9.62 18-FEB-14:55 22.00
March 788242.44 75.36 16-MAR-16:06 28.72
April 4233891.36 132.26 11-APR-16:06 33.83
May 14204285.07 122.59 30-MAY-16:06 33.00
June 20517339.93 131.54 28-JUN-09:50 36.67
July 19777678.67 132.17 10-JUL-11:40 36.67
August 15459845.91 145.18 21-AUG-16:06 34.85
September 6281957.15 103.60 25-SEP-16:06 31.13
October 1507459.36 75.94 02-OCT-10:20 31.67
November 47761.88 41.06 11-NOV-13:05 24.78
December 7043.61 11.64 02-DEC-16:45 22.17
         
Annual Sum or Average 82832153.86      
Minimum of Months 962.14 9.62   22.00
Maximum of Months 20517339.93 145.18   36.67



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: M S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 5664.40 13.67 16-JAN-11:15 22.67
February 972.01 9.72 18-FEB-14:55 22.00
March 749856.40 75.43 16-MAR-16:06 28.72
April 3923372.27 101.13 28-APR-16:06 31.00
May 13474018.60 112.96 11-MAY-16:06 32.00
June 19734681.04 131.34 28-JUN-09:50 36.67
July 19215403.62 131.92 10-JUL-11:40 36.67
August 14964474.36 145.24 21-AUG-16:06 34.85
September 6091957.50 103.66 25-SEP-16:06 31.13
October 1445951.94 75.76 02-OCT-10:20 31.67
November 46897.31 41.04 11-NOV-13:05 24.78
December 6565.42 11.58 02-DEC-16:45 22.17
         
Annual Sum or Average 79659814.87      
Minimum of Months 972.01 9.72   22.00
Maximum of Months 19734681.04 145.24   36.67



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: T SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 20594323.51 630.67 01-JAN-07:00 1.50
February 23065431.18 384.97 13-FEB-06:00 8.00
March 29990587.44 656.62 26-MAR-06:00 0.50
April 2164828.14 59.13 01-APR-09:43 26.50
May 4847143.81 61.51 28-MAY-08:43 26.50
June 5852943.17 117.44 28-JUN-08:62 33.33
July 4583731.66 94.70 11-JUL-08:62 31.17
August 5015959.26 94.22 15-AUG-08:62 31.17
September 2618651.44 73.49 07-SEP-08:62 29.27
October 1086061.29 59.86 02-OCT-09:05 30.17
November 14146881.10 547.71 24-NOV-07:00 4.00
December 0.143238E+09 955.39 07-DEC-06:00 -1.0
         
Annual Sum or Average 0.257204E+09      
Minimum of Months 1086061.29 59.13   -1.0
Maximum of Months 0.143238E+09 955.39   33.33



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: T NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.105901E+09 945.64 01-JAN-08:00 0.50
February 0.111751E+09 524.85 05-FEB-04:00 8.00
March 61967444.64 773.53 26-MAR-06:00 0.50
April 2070770.32 65.02 13-APR-09:33 27.00
May 1620892.05 66.05 18-MAY-08:15 27.67
June 910369.06 74.38 23-JUN-07:05 28.17
July 461163.73 66.51 05-JUL-07:05 27.50
August 787799.20 63.47 23-AUG-08:15 27.33
September 1349265.60 68.86 16-SEP-09:03 27.35
October 6327012.99 232.72 26-OCT-06:00 8.00
November 75199828.31 826.47 24-NOV-06:00 3.00
December 0.449522E+09 1297.72 07-DEC-06:00 -1.0
         
Annual Sum or Average 0.817868E+09      
Minimum of Months 461163.73 63.47   -1.0
Maximum of Months 0.449522E+09 1297.72   28.17



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: T SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 20377779.63 650.88 01-JAN-07:00 1.50
February 22509850.66 429.57 05-FEB-04:00 8.00
March 25989892.16 671.48 26-MAR-06:00 0.50
April 441719.28 56.30 01-APR-09:45 26.50
May 1093126.33 62.56 17-MAY-07:55 27.00
June 2722164.12 114.09 28-JUN-08:62 33.33
July 2414958.48 91.30 11-JUL-08:62 31.17
August 2638114.05 90.42 15-AUG-08:62 31.17
September 1481874.49 70.89 07-SEP-08:62 29.27
October 403537.20 50.55 02-OCT-08:45 29.33
November 13365324.35 564.89 24-NOV-07:00 4.00
December 0.133897E+09 961.70 07-DEC-06:00 -1.0
         
Annual Sum or Average 0.227335E+09      
Minimum of Months 403537.20 50.55   -1.0
Maximum of Months 0.133897E+09 961.70   33.33



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: T NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.102570E+09 961.69 01-JAN-07:00 1.50
February 99730901.79 585.46 05-FEB-04:00 8.00
March 55675572.45 784.28 26-MAR-06:00 0.50
April 506884.79 62.46 13-APR-09:35 27.00
May 562284.62 69.18 18-MAY-08:15 27.67
June 544359.87 75.28 23-JUN-07:05 28.17
July 226848.12 68.68 05-JUL-07:05 27.50
August 458919.01 68.21 24-AUG-08:25 27.50
September 707709.18 67.25 29-SEP-08:25 27.75
October 3293127.30 208.95 26-OCT-06:00 8.00
November 69287431.88 866.29 24-NOV-06:00 3.00
December 0.415503E+09 1321.50 07-DEC-06:00 -1.0
         
Annual Sum or Average 0.749067E+09      
Minimum of Months 226848.12 62.46   -1.0
Maximum of Months 0.415503E+09 1321.50   28.17



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: T N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 35915035.67 540.05 01-JAN-08:02 1.37
February 18846935.29 252.02 05-FEB-04:00 8.00
March 16750237.10 372.68 27-MAR-06:00 1.60
April 1659794.94 59.33 13-APR-09:35 27.00
May 1535455.47 70.66 18-MAY-08:15 27.67
June 895654.42 77.84 23-JUN-07:05 28.17
July 421745.41 69.98 05-JUL-07:05 27.50
August 758093.90 67.43 23-AUG-08:15 27.33
September 1257528.67 68.66 29-SEP-08:25 27.75
October 1894892.83 62.49 06-OCT-08:45 27.33
November 20024824.30 469.95 24-NOV-06:00 3.00
December 0.197482E+09 824.81 07-DEC-06:00 -1.0
         
Annual Sum or Average 0.297442E+09      
Minimum of Months 421745.41 59.33   -1.0
Maximum of Months 0.197482E+09 824.81   28.17



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: T N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 36519325.60 544.62 01-JAN-08:00 0.50
February 18936259.53 259.65 05-FEB-04:00 8.00
March 16703262.82 372.53 27-MAR-06:00 1.60
April 1559948.93 60.21 13-APR-09:35 27.00
May 1441717.11 71.30 18-MAY-08:15 27.67
June 873502.26 77.95 23-JUN-07:05 28.17
July 411476.79 70.06 05-JUL-07:05 27.50
August 744543.60 67.74 23-AUG-08:15 27.33
September 1238559.19 68.73 29-SEP-08:25 27.75
October 1773931.63 63.04 06-OCT-08:45 27.33
November 20146745.31 474.10 24-NOV-06:00 3.00
December 0.197625E+09 826.88 07-DEC-06:00 -1.0
         
Annual Sum or Average 0.297975E+09      
Minimum of Months 411476.79 60.21   -1.0
Maximum of Months 0.197625E+09 826.88   28.17



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: T S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 2927842.30 215.54 01-JAN-07:00 1.50
February 948957.33 69.66 13-FEB-06:00 8.00
March 4262042.99 227.66 26-MAR-06:00 0.50
April 1994192.42 55.93 01-APR-09:45 26.50
May 4878547.90 61.27 17-MAY-07:55 27.00
June 6603519.01 118.47 28-JUN-08:62 33.33
July 5261152.54 95.39 11-JUL-08:62 31.17
August 5525588.66 94.94 15-AUG-08:62 31.17
September 2762476.97 74.40 07-SEP-08:35 30.67
October 955723.93 61.57 02-OCT-09:05 30.17
November 1239540.89 163.73 24-NOV-07:00 4.00
December 27885726.89 445.08 07-DEC-06:00 -1.0
         
Annual Sum or Average 65245311.83      
Minimum of Months 948957.33 55.93   -1.0
Maximum of Months 27885726.89 445.08   33.33



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: T S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 2985400.53 217.41 01-JAN-07:00 1.50
February 1058369.85 68.42 13-FEB-06:00 8.00
March 4193626.60 227.98 26-MAR-06:00 0.50
April 1741143.87 56.97 01-APR-09:45 26.50
May 4434871.70 61.85 17-MAY-07:55 27.00
June 6348191.54 118.39 28-JUN-08:62 33.33
July 5143618.91 95.31 11-JUL-08:62 31.17
August 5286177.12 94.86 15-AUG-08:62 31.17
September 2697668.91 74.24 07-SEP-08:35 30.67
October 881905.06 61.29 02-OCT-09:05 30.17
November 1264047.99 165.57 24-NOV-07:00 4.00
December 27627301.54 443.76 07-DEC-06:00 -1.0
         
Annual Sum or Average 63662323.62      
Minimum of Months 881905.06 56.97   -1.0
Maximum of Months 27627301.54 443.76   33.33



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: T CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:10 4.27
February 0.00 0.00 01-FEB-00:10 11.90
March 0.00 0.00 01-MAR-00:10 11.85
April 0.00 0.00 01-APR-00:10 15.28
May 0.00 0.00 01-MAY-00:10 19.10
June 0.00 0.00 01-JUN-00:10 25.83
July 0.00 0.00 01-JUL-00:10 27.73
August 0.00 0.00 01-AUG-00:10 29.40
September 0.00 0.00 01-SEP-00:10 26.22
October 0.00 0.00 01-OCT-00:10 25.15
November 0.00 0.00 01-NOV-00:10 17.23
December 0.00 0.00 01-DEC-00:10 9.20
         
Annual Sum or Average 0.00      
Minimum of Months 0.00 0.00   4.27
Maximum of Months 0.00 0.00   29.40



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: G CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:10 4.27
February 0.00 0.00 01-FEB-00:10 11.90
March 0.00 0.00 01-MAR-00:10 11.85
April 0.00 0.00 01-APR-00:10 15.28
May 0.00 0.00 01-MAY-00:10 19.10
June 0.00 0.00 01-JUN-00:10 25.83
July 0.00 0.00 01-JUL-00:10 27.73
August 0.00 0.00 01-AUG-00:10 29.40
September 0.00 0.00 01-SEP-00:10 26.22
October 0.00 0.00 01-OCT-00:10 25.15
November 0.00 0.00 01-NOV-00:10 17.23
December 0.00 0.00 01-DEC-00:10 9.20
         
Annual Sum or Average 0.00      
Minimum of Months 0.00 0.00   4.27
Maximum of Months 0.00 0.00   29.40



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: M CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:10 4.27
February 0.00 0.00 01-FEB-00:10 11.90
March 0.00 0.00 01-MAR-00:10 11.85
April 0.00 0.00 01-APR-00:10 15.28
May 0.00 0.00 01-MAY-00:10 19.10
June 0.00 0.00 01-JUN-00:10 25.83
July 0.00 0.00 01-JUL-00:10 27.73
August 0.00 0.00 01-AUG-00:10 29.40
September 0.00 0.00 01-SEP-00:10 26.22
October 0.00 0.00 01-OCT-00:10 25.15
November 0.00 0.00 01-NOV-00:10 17.23
December 0.00 0.00 01-DEC-00:10 9.20
         
Annual Sum or Average 0.00      
Minimum of Months 0.00 0.00   4.27
Maximum of Months 0.00 0.00   29.40



Table of Contents

Report: ZoneElectricSummaryMonthly

For: G SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: G NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: OFFICE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.393335E+09 376.01 03-JAN-08:09 0.621586E+09 544.92 03-JAN-08:09
February 0.364248E+09 376.01 01-FEB-08:09 0.574385E+09 544.92 01-FEB-08:09
March 0.422123E+09 376.01 01-MAR-08:09 0.663122E+09 544.92 01-MAR-08:09
April 0.386838E+09 376.01 03-APR-07:10 0.610467E+09 544.92 03-APR-07:10
May 0.412527E+09 376.01 01-MAY-07:10 0.649277E+09 544.92 01-MAY-07:10
June 0.406030E+09 376.01 01-JUN-07:10 0.638158E+09 544.92 01-JUN-07:10
July 0.393335E+09 376.01 03-JUL-07:10 0.621586E+09 544.92 03-JUL-07:10
August 0.422123E+09 376.01 01-AUG-07:10 0.663122E+09 544.92 01-AUG-07:10
September 0.386838E+09 376.01 01-SEP-07:10 0.610467E+09 544.92 01-SEP-07:10
October 0.402931E+09 376.01 02-OCT-07:10 0.635432E+09 544.92 02-OCT-07:10
November 0.386838E+09 376.01 01-NOV-07:10 0.610467E+09 544.92 01-NOV-07:10
December 0.393335E+09 376.01 01-DEC-08:09 0.621586E+09 544.92 01-DEC-08:09
             
Annual Sum or Average 0.477050E+10     0.751966E+10    
Minimum of Months 0.364248E+09 376.01   0.574385E+09 544.92  
Maximum of Months 0.422123E+09 376.01   0.663122E+09 544.92  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: G NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: G N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: G N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: G S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: G S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: M SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: M NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: M SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: M NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: M N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: M N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: M S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: M S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: T SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: T NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: T SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: T NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: T N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: T N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: T S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: T S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 39920365.00 44.89 01-JAN-19:10 0.103725E+10 588.62 01-JAN-17:10
February 36057103.87 44.89 01-FEB-19:10 0.936871E+09 588.62 01-FEB-17:10
March 39920365.00 44.89 01-MAR-19:10 0.103725E+10 588.62 01-MAR-17:10
April 38632611.29 44.89 01-APR-18:10 0.100379E+10 588.62 01-APR-16:10
May 39920365.00 44.89 01-MAY-18:10 0.103725E+10 588.62 01-MAY-16:10
June 38632611.29 44.89 01-JUN-18:10 0.100379E+10 588.62 01-JUN-16:10
July 39920365.00 44.89 01-JUL-18:10 0.103725E+10 588.62 01-JUL-16:10
August 39920365.00 44.89 01-AUG-18:10 0.103725E+10 588.62 01-AUG-16:10
September 38632611.29 44.89 01-SEP-18:10 0.100379E+10 588.62 01-SEP-16:10
October 39920365.00 44.89 01-OCT-18:10 0.103725E+10 588.62 01-OCT-16:10
November 38632611.29 44.89 01-NOV-18:10 0.100379E+10 588.62 01-NOV-16:10
December 39920365.00 44.89 01-DEC-19:10 0.103725E+10 588.62 01-DEC-17:10
             
Annual Sum or Average 0.470030E+09     0.122128E+11    
Minimum of Months 36057103.87 44.89   0.936871E+09 588.62  
Maximum of Months 39920365.00 44.89   0.103725E+10 588.62  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: T CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY []
January 0.732995E+09 273.67 01-JAN-00:10 0.00 0.00
February 0.662060E+09 273.67 01-FEB-00:10 0.00 0.00
March 0.732995E+09 273.67 01-MAR-00:10 0.00 0.00
April 0.709350E+09 273.67 01-APR-00:10 0.00 0.00
May 0.732995E+09 273.67 01-MAY-00:10 0.00 0.00
June 0.709350E+09 273.67 01-JUN-00:10 0.00 0.00
July 0.732995E+09 273.67 01-JUL-00:10 0.00 0.00
August 0.732995E+09 273.67 01-AUG-00:10 0.00 0.00
September 0.709350E+09 273.67 01-SEP-00:10 0.00 0.00
October 0.732995E+09 273.67 01-OCT-00:10 0.00 0.00
November 0.709350E+09 273.67 01-NOV-00:10 0.00 0.00
December 0.732995E+09 273.67 01-DEC-00:10 0.00 0.00
           
Annual Sum or Average 0.863042E+10     0.00 0.00
Minimum of Months 0.662060E+09 273.67   0.00 0.00
Maximum of Months 0.732995E+09 273.67   0.00 0.00



Table of Contents

Report: ZoneElectricSummaryMonthly

For: G CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.732995E+09 273.67 01-JAN-00:10 0.318376E+10 2344.96 01-JAN-07:10
February 0.662060E+09 273.67 01-FEB-00:10 0.287565E+10 2344.96 01-FEB-07:10
March 0.732995E+09 273.67 01-MAR-00:10 0.318376E+10 2344.96 01-MAR-07:10
April 0.709350E+09 273.67 01-APR-00:10 0.308106E+10 2344.96 01-APR-06:10
May 0.732995E+09 273.67 01-MAY-00:10 0.318376E+10 2344.96 01-MAY-06:10
June 0.709350E+09 273.67 01-JUN-00:10 0.308106E+10 2344.96 01-JUN-06:10
July 0.732995E+09 273.67 01-JUL-00:10 0.318376E+10 2344.96 01-JUL-06:10
August 0.732995E+09 273.67 01-AUG-00:10 0.318376E+10 2344.96 01-AUG-06:10
September 0.709350E+09 273.67 01-SEP-00:10 0.308106E+10 2344.96 01-SEP-06:10
October 0.732995E+09 273.67 01-OCT-00:10 0.318376E+10 2344.96 01-OCT-06:10
November 0.709350E+09 273.67 01-NOV-00:10 0.308106E+10 2344.96 01-NOV-06:10
December 0.732995E+09 273.67 01-DEC-00:10 0.318376E+10 2344.96 01-DEC-07:10
             
Annual Sum or Average 0.863042E+10     0.374862E+11    
Minimum of Months 0.662060E+09 273.67   0.287565E+10 2344.96  
Maximum of Months 0.732995E+09 273.67   0.318376E+10 2344.96  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: M CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY []
January 0.732995E+09 273.67 01-JAN-00:10 0.00 0.00
February 0.662060E+09 273.67 01-FEB-00:10 0.00 0.00
March 0.732995E+09 273.67 01-MAR-00:10 0.00 0.00
April 0.709350E+09 273.67 01-APR-00:10 0.00 0.00
May 0.732995E+09 273.67 01-MAY-00:10 0.00 0.00
June 0.709350E+09 273.67 01-JUN-00:10 0.00 0.00
July 0.732995E+09 273.67 01-JUL-00:10 0.00 0.00
August 0.732995E+09 273.67 01-AUG-00:10 0.00 0.00
September 0.709350E+09 273.67 01-SEP-00:10 0.00 0.00
October 0.732995E+09 273.67 01-OCT-00:10 0.00 0.00
November 0.709350E+09 273.67 01-NOV-00:10 0.00 0.00
December 0.732995E+09 273.67 01-DEC-00:10 0.00 0.00
           
Annual Sum or Average 0.863042E+10     0.00 0.00
Minimum of Months 0.662060E+09 273.67   0.00 0.00
Maximum of Months 0.732995E+09 273.67   0.00 0.00



Table of Contents

Report: SpaceGainsMonthly

For: G SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 164728.54 70016499.76
February 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 62454229.37
March 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 758141.66 70691521.21
April 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 17148904.83 20518865.44
May 0.424935E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 34513948.83 9753980.31
June 0.406980E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 65670131.45 2044147.03
July 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 59000400.75 1388698.88
August 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 42093687.53 2944198.02
September 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 33350122.69 5944493.35
October 0.430920E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 11190910.37 38762732.28
November 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 459173.32 65964345.52
December 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 53405.90 69466652.41
                   
Annual Sum or Average 0.505732E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.264404E+09 0.419950E+09
Minimum of Months 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 1388698.88
Maximum of Months 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 65670131.45 70691521.21



Table of Contents

Report: SpaceGainsMonthly

For: G NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 557053.65 61936725.65
February 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 54823112.02
March 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 1532996.79 63845274.79
April 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 20952891.80 19757251.34
May 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 40092000.94 9627331.49
June 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 71171649.10 2022327.80
July 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 63856900.27 1359039.44
August 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 46749129.01 2846605.63
September 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 37655687.07 5669298.59
October 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 13594073.38 37504989.36
November 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 1142048.76 62829662.18
December 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 90175.72 63612798.95
                   
Annual Sum or Average 0.512427E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.297395E+09 0.385834E+09
Minimum of Months 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 1359039.44
Maximum of Months 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 71171649.10 63845274.79



Table of Contents

Report: SpaceGainsMonthly

For: OFFICE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.227408E+09 0.393335E+09 0.621586E+09 0.00 0.00 0.00 0.00 424249.85 70639984.59
February 0.216037E+09 0.364248E+09 0.574385E+09 0.00 0.00 0.00 0.00 0.00 61165403.26
March 0.261519E+09 0.422123E+09 0.663122E+09 0.00 0.00 0.00 0.00 1130340.61 72361714.85
April 0.227408E+09 0.386838E+09 0.610467E+09 0.00 0.00 0.00 0.00 11830499.34 27745088.22
May 0.250148E+09 0.412527E+09 0.649277E+09 0.00 0.00 0.00 0.00 25256404.45 17062894.97
June 0.250148E+09 0.406030E+09 0.638158E+09 0.00 0.00 0.00 0.00 49031405.71 7164963.87
July 0.227408E+09 0.393335E+09 0.621586E+09 0.00 0.00 0.00 0.00 39366275.56 8701820.82
August 0.261519E+09 0.422123E+09 0.663122E+09 0.00 0.00 0.00 0.00 30075764.71 11837948.03
September 0.227408E+09 0.386838E+09 0.610467E+09 0.00 0.00 0.00 0.00 21392752.05 18123356.28
October 0.238778E+09 0.402931E+09 0.635432E+09 0.00 0.00 0.00 0.00 7905983.65 48309532.48
November 0.227408E+09 0.386838E+09 0.610467E+09 0.00 0.00 0.00 0.00 810318.25 69076725.30
December 0.227408E+09 0.393335E+09 0.621586E+09 0.00 0.00 0.00 0.00 38723.46 69063132.28
                   
Annual Sum or Average 0.284259E+10 0.477050E+10 0.751966E+10 0.00 0.00 0.00 0.00 0.187263E+09 0.481253E+09
Minimum of Months 0.216037E+09 0.364248E+09 0.574385E+09 0.00 0.00 0.00 0.00 0.00 7164963.87
Maximum of Months 0.261519E+09 0.422123E+09 0.663122E+09 0.00 0.00 0.00 0.00 49031405.71 72361714.85



Table of Contents

Report: SpaceGainsMonthly

For: G NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 554842.78 61880860.37
February 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 55330210.67
March 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 1509778.01 64622358.54
April 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 20927038.51 20057334.70
May 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 40073839.06 9871336.83
June 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 71168328.97 2073727.51
July 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 63855916.96 1387260.51
August 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 46747381.18 2898231.42
September 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 37653286.65 5758546.92
October 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 13591072.78 37807168.55
November 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 1141104.82 62720820.31
December 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 89513.25 63753516.22
                   
Annual Sum or Average 0.512427E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.297312E+09 0.388161E+09
Minimum of Months 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 1387260.51
Maximum of Months 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 71168328.97 64622358.54



Table of Contents

Report: SpaceGainsMonthly

For: G N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 330987.90 38393438.98
February 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 35192121.38
March 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 908822.62 40715355.95
April 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 12632954.37 11885098.13
May 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 24180999.58 5856688.89
June 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 42926293.02 1215793.56
July 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 38515769.99 815364.11
August 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 28195821.63 1698872.34
September 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 22709721.93 3372544.58
October 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 8196316.18 22361903.55
November 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 688215.80 37799746.64
December 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 53592.76 39469619.41
                   
Annual Sum or Average 0.512427E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.179339E+09 0.238777E+09
Minimum of Months 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 815364.11
Maximum of Months 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 42926293.02 40715355.95



Table of Contents

Report: SpaceGainsMonthly

For: G N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 331001.28 38380282.30
February 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 35245665.92
March 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 908254.62 40776748.10
April 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 12632213.46 11892921.77
May 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 24180498.18 5859523.17
June 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 42926238.08 1215976.27
July 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 38515751.21 815500.45
August 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 28195807.45 1700004.01
September 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 22709717.91 3373648.07
October 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 8196122.48 22402080.28
November 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 688170.77 37794093.80
December 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 53546.50 39486059.52
                   
Annual Sum or Average 0.512427E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.179337E+09 0.238943E+09
Minimum of Months 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 815500.45
Maximum of Months 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 42926238.08 40776748.10



Table of Contents

Report: SpaceGainsMonthly

For: G S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 98897.14 42653347.05
February 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 39078439.24
March 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 428699.15 44365863.56
April 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 10335595.09 12459003.00
May 0.424935E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 20841945.11 5944995.66
June 0.406980E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 39629979.34 1232356.00
July 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 35602787.49 834798.29
August 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 25404657.22 1764484.98
September 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 20120094.60 3558165.65
October 0.430920E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 6748601.94 23435867.05
November 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 275584.73 39910112.61
December 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 32153.06 42332525.78
                   
Annual Sum or Average 0.505732E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.159519E+09 0.257570E+09
Minimum of Months 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 834798.29
Maximum of Months 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 39629979.34 44365863.56



Table of Contents

Report: SpaceGainsMonthly

For: G S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 98967.19 42630485.51
February 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 39055483.49
March 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 426544.78 44383005.52
April 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 10320917.57 12523406.37
May 0.424935E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 20781928.31 6002552.96
June 0.406980E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 39606435.79 1262893.95
July 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 35586360.25 852115.80
August 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 25390643.36 1801982.57
September 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 20113347.61 3627523.98
October 0.430920E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 6746441.49 23522735.05
November 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 275779.47 39944338.85
December 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 32153.07 42318187.79
                   
Annual Sum or Average 0.505732E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.159380E+09 0.257925E+09
Minimum of Months 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 852115.80
Maximum of Months 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 39606435.79 44383005.52



Table of Contents

Report: SpaceGainsMonthly

For: M SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 233096.35 0.101845E+09
February 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 94626954.54
March 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 897850.08 0.109944E+09
April 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 24456860.06 30096299.07
May 0.424935E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 49222642.48 14265185.86
June 0.406980E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 94164973.65 2947804.78
July 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 84654618.74 1938984.37
August 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 60430406.37 4009362.27
September 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 47865161.19 7916257.86
October 0.430920E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 16039644.32 54935783.37
November 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 651426.72 94150661.51
December 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 75418.84 99637695.28
                   
Annual Sum or Average 0.505732E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.378692E+09 0.616314E+09
Minimum of Months 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 1938984.37
Maximum of Months 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 94164973.65 0.109944E+09



Table of Contents

Report: SpaceGainsMonthly

For: M NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 727839.61 93825012.50
February 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 88298431.30
March 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 2114846.04 0.104821E+09
April 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 29954135.09 29307237.31
May 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 57432475.24 14111675.32
June 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 0.102073E+09 2926952.30
July 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 91544913.00 1908910.60
August 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 67005491.26 3891198.05
September 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 53955303.50 7599710.79
October 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 19467437.20 52100619.07
November 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 1628986.42 88035043.71
December 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 128773.47 89973880.83
                   
Annual Sum or Average 0.512427E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.426033E+09 0.576800E+09
Minimum of Months 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 1908910.60
Maximum of Months 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 0.102073E+09 0.104821E+09



Table of Contents

Report: SpaceGainsMonthly

For: M SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 232808.84 0.102182E+09
February 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 95292994.52
March 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 891566.32 0.110768E+09
April 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 24408671.42 30815708.48
May 0.424935E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 49026790.27 14748896.36
June 0.406980E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 94027093.92 3045833.94
July 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 84508068.02 1994922.40
August 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 60274873.54 4102829.34
September 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 47774765.49 8072053.34
October 0.430920E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 16006058.36 55547638.92
November 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 650857.72 94438799.13
December 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 75364.51 99987540.84
                   
Annual Sum or Average 0.505732E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.377877E+09 0.620998E+09
Minimum of Months 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 1994922.40
Maximum of Months 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 94027093.92 0.110768E+09



Table of Contents

Report: SpaceGainsMonthly

For: M NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 721842.01 93541364.74
February 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 88638567.61
March 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 2112255.16 0.105385E+09
April 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 29945288.99 29859711.15
May 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 57421742.56 14527543.24
June 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 0.102072E+09 3020736.17
July 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 91542834.75 1958812.38
August 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 66999231.02 3985590.61
September 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 53940564.49 7757645.21
October 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 19456429.80 52853117.68
November 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 1625739.84 87979092.43
December 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 126770.53 90298830.27
                   
Annual Sum or Average 0.512427E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.425965E+09 0.579806E+09
Minimum of Months 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 1958812.38
Maximum of Months 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 0.102072E+09 0.105385E+09



Table of Contents

Report: SpaceGainsMonthly

For: M N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 434234.19 57457708.48
February 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 54375622.87
March 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 1275536.69 63817956.92
April 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 18067903.40 17438657.86
May 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 34643681.56 8521986.21
June 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 61568151.77 1742688.13
July 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 55217426.40 1145771.14
August 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 40416340.53 2334271.67
September 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 32543413.05 4574577.98
October 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 11742063.12 31149920.24
November 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 980469.65 53669416.36
December 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 75332.74 56615310.95
                   
Annual Sum or Average 0.512427E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.256965E+09 0.352844E+09
Minimum of Months 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 1145771.14
Maximum of Months 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 61568151.77 63817956.92



Table of Contents

Report: SpaceGainsMonthly

For: M N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 434047.18 57448091.48
February 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 54395209.75
March 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 1275462.42 63850589.46
April 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 18067493.37 17450518.25
May 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 34643132.37 8526500.75
June 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 61567868.47 1742959.22
July 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 55217301.84 1146013.10
August 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 40416202.29 2335498.85
September 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 32543020.77 4576486.11
October 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 11741831.02 31177233.61
November 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 980369.33 53670228.56
December 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 75277.61 56648000.77
                   
Annual Sum or Average 0.512427E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.256962E+09 0.352967E+09
Minimum of Months 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 1146013.10
Maximum of Months 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 61567868.47 63850589.46



Table of Contents

Report: SpaceGainsMonthly

For: M S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 140020.80 61802506.64
February 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 57671683.88
March 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 540543.88 66726152.05
April 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 14759430.60 18125694.52
May 0.424935E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 29763639.47 8615791.30
June 0.406980E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 56866643.69 1757151.09
July 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 51131374.63 1165470.23
August 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 36508071.43 2417015.15
September 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 28894296.27 4782357.98
October 0.430920E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 9672945.53 33327416.89
November 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 391365.16 57113305.94
December 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 45443.72 60951607.79
                   
Annual Sum or Average 0.505732E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.228714E+09 0.374456E+09
Minimum of Months 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 1165470.23
Maximum of Months 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 56866643.69 66726152.05



Table of Contents

Report: SpaceGainsMonthly

For: M S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 140016.56 61806079.51
February 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 57691126.18
March 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 539785.79 66774816.50
April 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 14755270.79 18140781.91
May 0.424935E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 29748342.06 8623126.70
June 0.406980E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 56859062.10 1757926.35
July 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 51124727.27 1165934.51
August 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 36502281.84 2418711.53
September 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 28891129.70 4785574.10
October 0.430920E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 9671870.67 33343671.12
November 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 391357.93 57117673.75
December 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 45443.65 60960551.33
                   
Annual Sum or Average 0.505732E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.228669E+09 0.374586E+09
Minimum of Months 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 1165934.51
Maximum of Months 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 56859062.10 66774816.50



Table of Contents

Report: SpaceGainsMonthly

For: T SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 299484.63 0.124341E+09
February 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 0.113029E+09
March 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 1153074.54 0.133095E+09
April 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 32047751.38 38101094.82
May 0.424935E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 64575510.71 17817774.03
June 0.406980E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 0.123938E+09 3644855.50
July 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 0.111290E+09 2440011.61
August 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 79375865.07 5118275.67
September 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 62824086.64 9967451.96
October 0.430920E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 21005416.20 68421264.46
November 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 839652.12 0.115851E+09
December 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 96380.06 0.119480E+09
                   
Annual Sum or Average 0.505732E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.497445E+09 0.751306E+09
Minimum of Months 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 2440011.61
Maximum of Months 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 0.123938E+09 0.133095E+09



Table of Contents

Report: SpaceGainsMonthly

For: T NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 1016867.76 0.108334E+09
February 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 99924617.08
March 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 2760307.45 0.123759E+09
April 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 39346905.94 37367910.94
May 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 75536365.51 17850619.79
June 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 0.134482E+09 3723953.83
July 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 0.120505E+09 2452094.22
August 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 88160613.98 5104681.00
September 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 70919705.28 9809180.85
October 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 25602942.90 62362624.77
November 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 2187997.84 0.102394E+09
December 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 190286.15 0.106158E+09
                   
Annual Sum or Average 0.512427E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.560709E+09 0.679240E+09
Minimum of Months 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 2452094.22
Maximum of Months 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 0.134482E+09 0.123759E+09



Table of Contents

Report: SpaceGainsMonthly

For: T SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 299333.11 0.125458E+09
February 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 0.114669E+09
March 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 1151636.63 0.134875E+09
April 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 31988458.27 39594490.29
May 0.424935E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 64380817.57 18727452.45
June 0.406980E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 0.123767E+09 3837705.63
July 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 0.111130E+09 2541462.55
August 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 79195324.10 5279677.28
September 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 62716842.10 10242192.50
October 0.430920E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 20962198.65 69830026.51
November 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 837678.53 0.116837E+09
December 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 96383.10 0.120501E+09
                   
Annual Sum or Average 0.505732E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.496526E+09 0.762394E+09
Minimum of Months 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 2541462.55
Maximum of Months 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 0.123767E+09 0.134875E+09



Table of Contents

Report: SpaceGainsMonthly

For: T NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 954004.77 0.107924E+09
February 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 0.100441E+09
March 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 2744266.21 0.125104E+09
April 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 39301510.69 38884340.96
May 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 75506919.46 18705805.34
June 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 0.134479E+09 3915121.99
July 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 0.120500E+09 2553324.31
August 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 88146642.06 5271950.79
September 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 70895515.86 10107252.09
October 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 25533968.36 64785993.50
November 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 2112551.46 0.102005E+09
December 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 165932.63 0.105792E+09
                   
Annual Sum or Average 0.512427E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.560340E+09 0.685490E+09
Minimum of Months 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 2553324.31
Maximum of Months 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 0.134479E+09 0.125104E+09



Table of Contents

Report: SpaceGainsMonthly

For: T N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 601127.60 66454596.55
February 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 61471331.18
March 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 1661904.84 75956487.11
April 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 23722093.57 22704200.41
May 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 45555308.82 10979229.57
June 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 81116019.18 2267344.36
July 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 72683857.03 1501215.79
August 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 53173302.86 3113121.91
September 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 42771360.24 6002796.79
October 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 15424080.00 38390992.87
November 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 1305931.77 62735446.82
December 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 112045.43 64479626.96
                   
Annual Sum or Average 0.512427E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.338127E+09 0.416056E+09
Minimum of Months 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 1501215.79
Maximum of Months 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 81116019.18 75956487.11



Table of Contents

Report: SpaceGainsMonthly

For: T N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 597745.05 66432516.83
February 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 61566647.82
March 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 1660770.91 76055068.75
April 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 23719538.66 22745936.70
May 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 45553665.72 10992876.06
June 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 81115999.37 2268245.56
July 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 72683621.70 1501986.28
August 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 53172862.32 3115799.92
September 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 42770172.65 6006994.89
October 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 15420917.74 38701938.32
November 0.421173E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 1301110.27 62647693.97
December 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 110038.39 64484178.87
                   
Annual Sum or Average 0.512427E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.338106E+09 0.416520E+09
Minimum of Months 0.393095E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 1501986.28
Maximum of Months 0.435212E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 81115999.37 76055068.75



Table of Contents

Report: SpaceGainsMonthly

For: T S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 180137.85 77952677.53
February 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 71195222.21
March 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 694647.67 82669620.14
April 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 19319816.33 23347846.08
May 0.424935E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 38938971.17 10948668.67
June 0.406980E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 74776271.99 2218679.92
July 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 67139939.86 1493198.99
August 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 47893688.96 3123400.16
September 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 37893680.58 6106108.69
October 0.430920E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 12664319.70 42494994.34
November 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 504041.72 72206655.75
December 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 58141.71 74606910.65
                   
Annual Sum or Average 0.505732E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.300064E+09 0.468364E+09
Minimum of Months 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 1493198.99
Maximum of Months 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 74776271.99 82669620.14



Table of Contents

Report: SpaceGainsMonthly

For: T S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 180097.20 77973502.56
February 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 71294355.27
March 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 694416.39 82786955.77
April 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 19314853.10 23386930.97
May 0.424935E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 38924538.00 10966339.50
June 0.406980E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 74770276.11 2220007.40
July 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 67135103.93 1494048.21
August 0.418950E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 47888581.79 3125820.42
September 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 37890181.41 6110928.73
October 0.430920E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 12662969.83 42546552.56
November 0.418950E+09 38632611.29 0.100379E+10 0.00 0.00 0.00 0.00 503958.95 72227455.68
December 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 58137.59 74653357.91
                   
Annual Sum or Average 0.505732E+10 0.470030E+09 0.122128E+11 0.00 0.00 0.00 0.00 0.300023E+09 0.468786E+09
Minimum of Months 0.389025E+09 36057103.87 0.936871E+09 0.00 0.00 0.00 0.00 0.00 1494048.21
Maximum of Months 0.436905E+09 39920365.00 0.103725E+10 0.00 0.00 0.00 0.00 74770276.11 82786955.77



Table of Contents

Report: SpaceGainsMonthly

For: T CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.727675E+09 0.732995E+09 0.00 0.00 0.00 0.00 0.00 54251.88 21745095.80
February 0.657255E+09 0.662060E+09 0.00 0.00 0.00 0.00 0.00 0.00 19631516.13
March 0.727675E+09 0.732995E+09 0.00 0.00 0.00 0.00 0.00 128746.75 24161458.65
April 0.704201E+09 0.709350E+09 0.00 0.00 0.00 0.00 0.00 3450469.03 8097288.08
May 0.727675E+09 0.732995E+09 0.00 0.00 0.00 0.00 0.00 7776623.53 4214652.32
June 0.704201E+09 0.709350E+09 0.00 0.00 0.00 0.00 0.00 16002337.38 1149853.21
July 0.727675E+09 0.732995E+09 0.00 0.00 0.00 0.00 0.00 13555187.65 1040522.43
August 0.727675E+09 0.732995E+09 0.00 0.00 0.00 0.00 0.00 9595322.48 1790526.60
September 0.704201E+09 0.709350E+09 0.00 0.00 0.00 0.00 0.00 7108916.56 3019408.38
October 0.727675E+09 0.732995E+09 0.00 0.00 0.00 0.00 0.00 2406722.07 13155100.18
November 0.704201E+09 0.709350E+09 0.00 0.00 0.00 0.00 0.00 74023.04 20581501.69
December 0.727675E+09 0.732995E+09 0.00 0.00 0.00 0.00 0.00 10112.44 20247024.77
                   
Annual Sum or Average 0.856778E+10 0.863042E+10 0.00 0.00 0.00 0.00 0.00 60162712.81 0.138834E+09
Minimum of Months 0.657255E+09 0.662060E+09 0.00 0.00 0.00 0.00 0.00 0.00 1040522.43
Maximum of Months 0.727675E+09 0.732995E+09 0.00 0.00 0.00 0.00 0.00 16002337.38 24161458.65



Table of Contents

Report: SpaceGainsMonthly

For: G CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.727675E+09 0.732995E+09 0.159188E+09 0.00 0.00 0.00 0.00 3025656.38 0.177399E+10
February 0.657255E+09 0.662060E+09 0.143783E+09 0.00 0.00 0.00 0.00 0.00 0.192131E+10
March 0.727675E+09 0.732995E+09 0.159188E+09 0.00 0.00 0.00 0.00 14298100.84 0.161292E+10
April 0.704201E+09 0.709350E+09 0.154053E+09 0.00 0.00 0.00 0.00 0.278434E+09 0.667964E+09
May 0.727675E+09 0.732995E+09 0.159188E+09 0.00 0.00 0.00 0.00 0.508406E+09 0.389251E+09
June 0.704201E+09 0.709350E+09 0.154053E+09 0.00 0.00 0.00 0.00 0.997222E+09 0.136896E+09
July 0.727675E+09 0.732995E+09 0.159188E+09 0.00 0.00 0.00 0.00 0.789147E+09 0.135712E+09
August 0.727675E+09 0.732995E+09 0.159188E+09 0.00 0.00 0.00 0.00 0.737279E+09 0.206279E+09
September 0.704201E+09 0.709350E+09 0.154053E+09 0.00 0.00 0.00 0.00 0.475500E+09 0.310493E+09
October 0.727675E+09 0.732995E+09 0.159188E+09 0.00 0.00 0.00 0.00 0.160344E+09 0.113273E+10
November 0.704201E+09 0.709350E+09 0.154053E+09 0.00 0.00 0.00 0.00 1482820.88 0.179485E+10
December 0.727675E+09 0.732995E+09 0.159188E+09 0.00 0.00 0.00 0.00 6333.77 0.233325E+10
                   
Annual Sum or Average 0.856778E+10 0.863042E+10 0.187431E+10 0.00 0.00 0.00 0.00 0.396515E+10 0.124156E+11
Minimum of Months 0.657255E+09 0.662060E+09 0.143783E+09 0.00 0.00 0.00 0.00 0.00 0.135712E+09
Maximum of Months 0.727675E+09 0.732995E+09 0.159188E+09 0.00 0.00 0.00 0.00 0.997222E+09 0.233325E+10



Table of Contents

Report: SpaceGainsMonthly

For: M CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.727675E+09 0.732995E+09 0.00 0.00 0.00 0.00 0.00 24601.87 19182881.00
February 0.657255E+09 0.662060E+09 0.00 0.00 0.00 0.00 0.00 0.00 17589893.72
March 0.727675E+09 0.732995E+09 0.00 0.00 0.00 0.00 0.00 85959.44 21113628.87
April 0.704201E+09 0.709350E+09 0.00 0.00 0.00 0.00 0.00 2909087.91 6675964.71
May 0.727675E+09 0.732995E+09 0.00 0.00 0.00 0.00 0.00 6464606.93 3573916.06
June 0.704201E+09 0.709350E+09 0.00 0.00 0.00 0.00 0.00 13178093.79 984061.41
July 0.727675E+09 0.732995E+09 0.00 0.00 0.00 0.00 0.00 11340413.11 833345.23
August 0.727675E+09 0.732995E+09 0.00 0.00 0.00 0.00 0.00 7987599.39 1419791.99
September 0.704201E+09 0.709350E+09 0.00 0.00 0.00 0.00 0.00 5979381.52 2464963.10
October 0.727675E+09 0.732995E+09 0.00 0.00 0.00 0.00 0.00 1955579.22 11198916.34
November 0.704201E+09 0.709350E+09 0.00 0.00 0.00 0.00 0.00 41153.56 17982851.35
December 0.727675E+09 0.732995E+09 0.00 0.00 0.00 0.00 0.00 644.18 18199378.95
                   
Annual Sum or Average 0.856778E+10 0.863042E+10 0.00 0.00 0.00 0.00 0.00 49967120.92 0.121220E+09
Minimum of Months 0.657255E+09 0.662060E+09 0.00 0.00 0.00 0.00 0.00 0.00 833345.23
Maximum of Months 0.727675E+09 0.732995E+09 0.00 0.00 0.00 0.00 0.00 13178093.79 21113628.87



Table of Contents

Report: PeakSpaceGainsMonthly

For: G SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 8.23 31-JAN-17:09 101.45 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 112.66 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 15.29 16-MAR-16:10 88.60 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 71.25 30-APR-16:00 49.94 21-APR-06:00
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 109.75 20-MAY-14:00 33.29 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 130.47 30-JUN-16:10 18.41 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 138.72 22-JUL-16:00 20.01 01-JUL-06:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 109.40 13-AUG-16:00 55.58 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 81.85 17-SEP-12:00 28.04 27-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 57.06 04-OCT-17:00 84.73 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 17.57 19-NOV-15:00 125.16 22-NOV-12:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 5.42 25-DEC-16:00 87.91 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   18.41  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 138.72   125.16  



Table of Contents

Report: PeakSpaceGainsMonthly

For: G NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 10.82 31-JAN-14:00 90.10 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 104.49 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 22.88 15-MAR-13:00 84.14 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 71.25 30-APR-16:00 49.68 21-APR-06:00
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 109.75 20-MAY-14:00 33.29 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 141.39 19-JUN-14:00 18.21 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 138.72 22-JUL-16:00 19.47 01-JUL-06:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 109.40 13-AUG-16:00 45.18 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 86.82 01-SEP-16:00 26.04 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 57.69 10-OCT-15:00 91.37 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 17.68 01-NOV-16:00 101.46 24-NOV-10:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 5.42 25-DEC-16:00 80.77 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   18.21  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 141.39   104.49  



Table of Contents

Report: PeakSpaceGainsMonthly

For: OFFICE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 451.21 03-JAN-08:09 376.01 03-JAN-08:09 544.92 03-JAN-08:09 0.00 0.00 0.00 0.00 10.82 31-JAN-14:00 93.63 01-JAN-01:00
February 451.21 01-FEB-08:09 376.01 01-FEB-08:09 544.92 01-FEB-08:09 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 111.85 02-FEB-23:00
March 451.21 01-MAR-08:09 376.01 01-MAR-08:09 544.92 01-MAR-08:09 0.00 0.00 0.00 0.00 22.88 15-MAR-13:00 85.11 28-MAR-04:00
April 451.21 03-APR-07:10 376.01 03-APR-07:10 544.92 03-APR-07:10 0.00 0.00 0.00 0.00 59.35 10-APR-16:00 56.47 16-APR-09:00
May 451.21 01-MAY-07:10 376.01 01-MAY-07:10 544.92 01-MAY-07:10 0.00 0.00 0.00 0.00 78.18 19-MAY-14:00 41.30 23-MAY-05:00
June 451.21 01-JUN-07:10 376.01 01-JUN-07:10 544.92 01-JUN-07:10 0.00 0.00 0.00 0.00 141.39 19-JUN-14:00 27.65 13-JUN-06:00
July 451.21 03-JUL-07:10 376.01 03-JUL-07:10 544.92 03-JUL-07:10 0.00 0.00 0.00 0.00 109.52 21-JUL-15:00 51.90 17-JUL-20:00
August 451.21 01-AUG-07:10 376.01 01-AUG-07:10 544.92 01-AUG-07:10 0.00 0.00 0.00 0.00 96.59 09-AUG-15:00 62.55 05-AUG-17:25
September 451.21 01-SEP-07:10 376.01 01-SEP-07:10 544.92 01-SEP-07:10 0.00 0.00 0.00 0.00 86.82 01-SEP-16:00 52.07 03-SEP-05:00
October 451.21 02-OCT-07:10 376.01 02-OCT-07:10 544.92 02-OCT-07:10 0.00 0.00 0.00 0.00 57.69 10-OCT-15:00 111.30 22-OCT-14:00
November 451.21 01-NOV-07:10 376.01 01-NOV-07:10 544.92 01-NOV-07:10 0.00 0.00 0.00 0.00 17.68 01-NOV-16:00 107.17 24-NOV-10:00
December 451.21 01-DEC-08:09 376.01 01-DEC-08:09 544.92 01-DEC-08:09 0.00 0.00 0.00 0.00 4.56 21-DEC-15:00 82.77 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 451.21   376.01   544.92   0.00 0.00 0.00 0.00 0.00   27.65  
Maximum of Months 451.21   376.01   544.92   0.00 0.00 0.00 0.00 141.39   111.85  



Table of Contents

Report: PeakSpaceGainsMonthly

For: G NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 10.82 31-JAN-14:00 90.10 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 104.16 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 22.88 15-MAR-13:00 84.08 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 71.25 30-APR-15:30 49.72 21-APR-06:00
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 109.75 20-MAY-14:00 33.29 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 141.39 19-JUN-14:00 18.58 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 138.72 22-JUL-16:00 19.64 01-JUL-06:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 109.40 13-AUG-16:00 45.78 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 86.82 01-SEP-16:00 26.68 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 57.69 10-OCT-15:00 93.15 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 17.68 01-NOV-16:00 104.70 24-NOV-10:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 5.42 25-DEC-16:00 81.50 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   18.58  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 141.39   104.70  



Table of Contents

Report: PeakSpaceGainsMonthly

For: G N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 6.52 31-JAN-14:00 55.04 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 66.24 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 13.80 15-MAR-13:00 53.15 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 42.98 30-APR-16:00 30.12 21-APR-06:00
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 66.20 20-MAY-14:00 20.08 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 85.29 19-JUN-14:00 11.05 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 83.67 22-JUL-16:00 11.70 01-JUL-06:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 65.99 13-AUG-16:00 26.29 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 52.37 01-SEP-16:00 15.58 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 34.80 10-OCT-15:00 55.21 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 10.66 01-NOV-16:00 63.57 24-NOV-10:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 3.27 25-DEC-16:00 51.22 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   11.05  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 85.29   66.24  



Table of Contents

Report: PeakSpaceGainsMonthly

For: G N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 6.52 31-JAN-14:00 54.99 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 66.25 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 13.80 15-MAR-13:00 53.18 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 42.98 30-APR-16:00 30.12 21-APR-06:00
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 66.20 20-MAY-14:00 20.08 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 85.29 19-JUN-14:00 11.05 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 83.67 22-JUL-16:00 11.70 01-JUL-06:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 65.99 13-AUG-16:00 26.31 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 52.37 01-SEP-16:00 15.59 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 34.80 10-OCT-15:00 55.28 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 10.66 01-NOV-16:00 63.62 24-NOV-10:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 3.27 25-DEC-16:00 51.24 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   11.05  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 85.29   66.25  



Table of Contents

Report: PeakSpaceGainsMonthly

For: G S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 4.97 31-JAN-17:10 63.65 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 67.95 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 9.22 16-MAR-16:09 55.86 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 42.98 30-APR-15:20 30.12 21-APR-06:00
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 66.20 20-MAY-14:00 20.08 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 78.70 30-JUN-16:10 11.17 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 83.67 22-JUL-16:00 12.04 01-JUL-06:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 65.99 13-AUG-16:00 32.36 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 49.37 17-SEP-12:00 17.01 27-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 34.42 04-OCT-17:00 51.25 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 10.60 19-NOV-15:00 75.49 22-NOV-12:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 3.27 25-DEC-16:00 54.93 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   11.17  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 83.67   75.49  



Table of Contents

Report: PeakSpaceGainsMonthly

For: G S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 4.97 31-JAN-17:10 63.28 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 67.95 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 9.25 16-MAR-16:06 55.72 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 42.98 30-APR-15:20 30.12 21-APR-06:00
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 66.20 20-MAY-14:00 20.08 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 78.70 30-JUN-16:10 11.49 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 83.67 22-JUL-16:00 12.24 01-JUL-06:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 65.99 13-AUG-16:00 32.98 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 49.37 17-SEP-12:00 17.35 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 34.42 04-OCT-17:00 51.89 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 10.60 19-NOV-15:00 75.49 22-NOV-12:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 3.27 25-DEC-16:00 54.93 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   11.49  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 83.67   75.49  



Table of Contents

Report: PeakSpaceGainsMonthly

For: M SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 11.78 31-JAN-17:10 148.35 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 162.13 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 21.87 16-MAR-16:10 135.84 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 102.17 30-APR-16:00 74.72 26-APR-20:30
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 157.46 20-MAY-14:00 47.95 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 187.27 30-JUN-16:10 26.45 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 199.07 22-JUL-16:00 28.29 01-JUL-06:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 157.00 13-AUG-16:00 77.64 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 117.40 17-SEP-12:00 36.50 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 81.83 04-OCT-17:00 116.02 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 25.09 19-NOV-15:00 180.19 22-NOV-12:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 7.71 25-DEC-16:00 123.84 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   26.45  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 199.07   180.19  



Table of Contents

Report: PeakSpaceGainsMonthly

For: M NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 15.47 31-JAN-14:00 132.10 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 157.06 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 32.68 15-MAR-13:00 130.69 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 102.17 30-APR-16:00 73.49 26-APR-20:52
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 157.46 20-MAY-14:00 47.95 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 202.92 19-JUN-14:00 26.20 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 199.07 22-JUL-16:00 27.68 01-JUL-06:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 157.00 13-AUG-16:00 59.50 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 124.54 01-SEP-16:00 34.70 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 82.76 10-OCT-15:00 110.73 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 25.28 01-NOV-16:00 138.54 24-NOV-10:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 7.71 25-DEC-16:00 112.93 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   26.20  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 202.92   157.06  



Table of Contents

Report: PeakSpaceGainsMonthly

For: M SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 11.78 31-JAN-17:09 147.83 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 162.13 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 21.87 16-MAR-16:10 135.21 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 102.17 30-APR-15:20 72.55 26-APR-20:30
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 157.46 20-MAY-14:00 47.95 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 187.27 30-JUN-16:10 27.31 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 199.07 22-JUL-16:00 28.76 01-JUL-06:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 157.00 13-AUG-16:00 79.51 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 117.40 17-SEP-12:00 37.81 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 81.83 04-OCT-17:00 118.26 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 25.09 19-NOV-15:00 180.19 22-NOV-12:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 7.71 25-DEC-16:00 125.27 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   27.31  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 199.07   180.19  



Table of Contents

Report: PeakSpaceGainsMonthly

For: M NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 15.47 31-JAN-14:00 130.75 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 156.44 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 32.68 15-MAR-13:00 130.22 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 102.17 30-APR-15:20 71.86 21-APR-06:00
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 157.46 20-MAY-14:00 47.95 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 202.92 19-JUN-14:00 26.94 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 199.07 22-JUL-16:00 28.09 01-JUL-06:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 157.00 13-AUG-16:00 60.43 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 124.54 01-SEP-16:00 35.97 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 82.76 10-OCT-15:00 128.57 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 25.28 01-NOV-16:00 144.75 24-NOV-10:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 7.71 25-DEC-16:00 113.78 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   26.94  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 202.92   156.44  



Table of Contents

Report: PeakSpaceGainsMonthly

For: M N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 9.33 31-JAN-14:00 83.58 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 97.79 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 19.71 15-MAR-13:00 81.24 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 61.63 30-APR-16:00 43.35 21-APR-06:00
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 94.98 20-MAY-14:00 28.92 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 122.40 19-JUN-14:00 15.73 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 120.07 22-JUL-16:00 16.59 01-JUL-06:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 94.70 13-AUG-16:00 35.22 05-AUG-18:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 75.12 01-SEP-16:00 21.14 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 49.92 10-OCT-15:00 67.26 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 15.25 01-NOV-16:00 89.06 24-NOV-10:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 4.65 25-DEC-16:00 72.55 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   15.73  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 122.40   97.79  



Table of Contents

Report: PeakSpaceGainsMonthly

For: M N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 9.33 31-JAN-14:00 83.48 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 97.79 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 19.71 15-MAR-13:00 81.26 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 61.63 30-APR-15:50 43.35 21-APR-06:00
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 94.98 20-MAY-14:00 28.92 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 122.40 19-JUN-14:00 15.73 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 120.07 22-JUL-16:00 16.58 01-JUL-06:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 94.70 13-AUG-16:00 35.23 05-AUG-18:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 75.12 01-SEP-16:00 21.15 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 49.92 10-OCT-15:00 67.45 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 15.25 01-NOV-16:00 89.16 24-NOV-10:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 4.65 25-DEC-16:00 72.59 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   15.73  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 122.40   97.79  



Table of Contents

Report: PeakSpaceGainsMonthly

For: M S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 7.10 31-JAN-17:10 92.59 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 97.79 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 13.27 16-MAR-16:06 83.80 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 61.63 30-APR-15:20 43.35 21-APR-06:00
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 94.98 20-MAY-14:00 28.92 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 112.96 30-JUN-16:10 15.85 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 120.07 22-JUL-16:00 16.95 01-JUL-06:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 94.70 13-AUG-16:00 45.52 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 70.81 17-SEP-12:00 22.27 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 49.36 04-OCT-17:00 70.66 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 15.13 19-NOV-15:00 108.69 22-NOV-12:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 4.65 25-DEC-16:00 78.81 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   15.85  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 120.07   108.69  



Table of Contents

Report: PeakSpaceGainsMonthly

For: M S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 7.10 31-JAN-17:10 92.57 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 97.79 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 13.27 16-MAR-16:06 83.80 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 61.63 30-APR-15:20 43.35 21-APR-06:00
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 94.98 20-MAY-14:00 28.92 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 112.96 30-JUN-16:10 15.86 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 120.07 22-JUL-16:00 16.95 01-JUL-06:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 94.70 13-AUG-16:00 45.58 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 70.81 17-SEP-12:00 22.29 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 49.36 04-OCT-17:00 70.75 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 15.13 19-NOV-15:00 108.69 22-NOV-12:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 4.65 25-DEC-16:00 78.83 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   15.86  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 120.07   108.69  



Table of Contents

Report: PeakSpaceGainsMonthly

For: T SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 15.44 31-JAN-17:10 171.94 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 200.42 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 28.69 16-MAR-16:10 157.77 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 134.56 30-APR-16:00 101.54 26-APR-19:00
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 207.60 20-MAY-14:00 63.23 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 247.13 30-JUN-16:10 30.42 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 262.58 22-JUL-16:00 34.70 26-JUL-24:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 207.08 13-AUG-16:00 110.76 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 154.70 17-SEP-12:00 40.89 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 107.82 04-OCT-17:00 149.11 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 32.75 19-NOV-15:00 239.23 22-NOV-12:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 9.99 25-DEC-16:00 149.71 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   30.42  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 262.58   239.23  



Table of Contents

Report: PeakSpaceGainsMonthly

For: T NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 20.25 31-JAN-14:00 171.93 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 171.70 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 42.69 15-MAR-13:00 157.77 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 134.56 30-APR-16:00 106.94 26-APR-18:50
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 207.60 20-MAY-14:00 62.41 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 267.71 19-JUN-14:00 31.04 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 262.58 22-JUL-16:00 34.70 26-JUL-24:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 207.08 13-AUG-16:00 81.06 28-AUG-16:54
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 164.15 01-SEP-16:00 40.42 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 109.07 10-OCT-15:00 138.50 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 33.11 01-NOV-16:00 165.14 24-NOV-10:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 9.99 25-DEC-16:00 149.71 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   31.04  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 267.71   171.93  



Table of Contents

Report: PeakSpaceGainsMonthly

For: T SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 15.44 31-JAN-17:10 171.93 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 199.28 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 28.69 16-MAR-16:10 157.77 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 134.56 30-APR-15:20 92.43 26-APR-19:00
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 207.60 20-MAY-14:00 62.99 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 247.10 30-JUN-16:10 31.83 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 262.58 22-JUL-16:00 34.70 26-JUL-24:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 207.08 13-AUG-16:00 112.55 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 154.70 17-SEP-12:00 43.21 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 107.82 04-OCT-17:00 153.30 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 32.75 19-NOV-15:00 239.23 22-NOV-12:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 9.99 25-DEC-16:00 149.71 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   31.83  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 262.58   239.23  



Table of Contents

Report: PeakSpaceGainsMonthly

For: T NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 20.25 31-JAN-14:00 171.93 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 170.71 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 42.69 15-MAR-13:00 157.77 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 134.56 30-APR-15:10 96.84 26-APR-20:52
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 207.60 20-MAY-14:00 62.03 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 267.71 19-JUN-14:00 32.37 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 262.58 22-JUL-16:00 34.70 26-JUL-24:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 207.08 13-AUG-16:00 82.23 28-AUG-16:54
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 164.15 01-SEP-16:00 42.71 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 109.07 10-OCT-15:00 175.27 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 33.11 01-NOV-16:00 165.14 24-NOV-10:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 9.99 25-DEC-16:00 149.71 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   32.37  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 267.71   175.27  



Table of Contents

Report: PeakSpaceGainsMonthly

For: T N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 12.22 31-JAN-14:00 103.71 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 108.11 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 25.75 15-MAR-13:00 95.16 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 81.16 30-APR-15:30 60.10 26-APR-20:52
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 125.22 20-MAY-14:00 38.42 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 161.48 19-JUN-14:00 19.18 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 158.38 22-JUL-16:00 20.93 26-JUL-24:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 124.91 13-AUG-16:00 47.77 28-AUG-16:54
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 99.01 01-SEP-16:00 25.35 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 65.79 10-OCT-15:00 84.88 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 19.97 01-NOV-16:00 99.61 24-NOV-10:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 6.03 25-DEC-16:00 90.30 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   19.18  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 161.48   108.11  



Table of Contents

Report: PeakSpaceGainsMonthly

For: T N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 12.22 31-JAN-14:00 103.71 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 107.89 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 25.75 15-MAR-13:00 95.16 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 81.16 30-APR-15:30 59.71 26-APR-20:52
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 125.22 20-MAY-14:00 38.42 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 161.48 19-JUN-14:00 19.17 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 158.38 22-JUL-16:00 20.93 26-JUL-24:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 124.91 13-AUG-16:00 47.81 28-AUG-16:54
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 99.01 01-SEP-16:00 25.36 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 65.79 10-OCT-15:00 85.60 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 19.97 01-NOV-16:00 99.61 24-NOV-10:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 6.03 25-DEC-16:00 90.30 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   19.17  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 161.48   107.89  



Table of Contents

Report: PeakSpaceGainsMonthly

For: T S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 9.31 31-JAN-17:10 108.93 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 127.53 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 17.31 16-MAR-16:10 97.65 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 81.16 30-APR-15:20 55.77 26-APR-19:00
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 125.22 20-MAY-14:00 38.42 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 149.07 30-JUN-16:10 18.81 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 158.38 22-JUL-16:00 20.93 26-JUL-24:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 124.91 13-AUG-16:00 66.12 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 93.31 17-SEP-12:00 25.66 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 65.03 04-OCT-17:00 91.28 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 19.75 19-NOV-15:00 144.30 22-NOV-12:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 6.03 25-DEC-16:00 90.30 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   18.81  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 158.38   144.30  



Table of Contents

Report: PeakSpaceGainsMonthly

For: T S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 237.50 01-JAN-00:10 44.89 01-JAN-19:10 588.62 01-JAN-17:10 0.00 0.00 0.00 0.00 9.31 31-JAN-17:10 108.86 01-JAN-01:00
February 237.50 01-FEB-00:10 44.89 01-FEB-19:10 588.62 01-FEB-17:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 127.56 02-FEB-23:00
March 237.50 01-MAR-00:10 44.89 01-MAR-19:10 588.62 01-MAR-17:10 0.00 0.00 0.00 0.00 17.31 16-MAR-16:10 97.56 28-MAR-04:00
April 237.50 01-APR-00:10 44.89 01-APR-18:10 588.62 01-APR-16:10 0.00 0.00 0.00 0.00 81.16 30-APR-15:20 55.53 26-APR-19:00
May 237.50 01-MAY-00:10 44.89 01-MAY-18:10 588.62 01-MAY-16:10 0.00 0.00 0.00 0.00 125.22 20-MAY-14:00 38.42 23-MAY-05:00
June 237.50 01-JUN-00:10 44.89 01-JUN-18:10 588.62 01-JUN-16:10 0.00 0.00 0.00 0.00 149.07 30-JUN-16:10 18.81 13-JUN-06:00
July 237.50 01-JUL-00:10 44.89 01-JUL-18:10 588.62 01-JUL-16:10 0.00 0.00 0.00 0.00 158.38 22-JUL-16:00 20.93 26-JUL-24:00
August 237.50 01-AUG-00:10 44.89 01-AUG-18:10 588.62 01-AUG-16:10 0.00 0.00 0.00 0.00 124.91 13-AUG-16:00 66.20 28-AUG-17:00
September 237.50 01-SEP-00:10 44.89 01-SEP-18:10 588.62 01-SEP-16:10 0.00 0.00 0.00 0.00 93.31 17-SEP-12:00 25.67 15-SEP-07:00
October 237.50 01-OCT-00:10 44.89 01-OCT-18:10 588.62 01-OCT-16:10 0.00 0.00 0.00 0.00 65.03 04-OCT-17:00 91.55 22-OCT-14:00
November 237.50 01-NOV-00:10 44.89 01-NOV-18:10 588.62 01-NOV-16:10 0.00 0.00 0.00 0.00 19.75 19-NOV-15:00 144.30 22-NOV-12:00
December 237.50 01-DEC-00:10 44.89 01-DEC-19:10 588.62 01-DEC-17:10 0.00 0.00 0.00 0.00 6.03 25-DEC-16:00 90.30 07-DEC-08:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 0.00   18.81  
Maximum of Months 237.50   44.89   588.62   0.00 0.00 0.00 0.00 158.38   144.30  



Table of Contents

Report: PeakSpaceGainsMonthly

For: T CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 397.10 01-JAN-00:10 273.67 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00 2.37 31-JAN-14:00 31.28 01-JAN-01:00
February 397.10 01-FEB-00:10 273.67 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 35.18 02-FEB-23:00
March 397.10 01-MAR-00:10 273.67 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00 4.14 15-MAR-13:00 29.08 28-MAR-04:00
April 397.10 01-APR-00:10 273.67 01-APR-00:10 0.00 0.00 0.00 0.00 0.00 16.53 30-APR-15:00 18.20 26-APR-20:52
May 397.10 01-MAY-00:10 273.67 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00 27.78 20-MAY-14:00 12.11 23-MAY-05:00
June 397.10 01-JUN-00:10 273.67 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00 34.61 19-JUN-14:00 6.44 13-JUN-06:00
July 397.10 01-JUL-00:10 273.67 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00 34.45 22-JUL-16:00 10.55 26-JUL-24:00
August 397.10 01-AUG-00:10 273.67 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00 27.36 13-AUG-16:00 21.36 28-AUG-16:52
September 397.10 01-SEP-00:10 273.67 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00 20.79 17-SEP-12:00 10.31 03-SEP-05:00
October 397.10 01-OCT-00:10 273.67 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00 12.93 10-OCT-15:00 30.85 22-OCT-14:00
November 397.10 01-NOV-00:10 273.67 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00 3.14 19-NOV-15:00 35.96 22-NOV-12:00
December 397.10 01-DEC-00:10 273.67 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00 0.88 25-DEC-14:00 24.63 07-DEC-08:00
                           
Annual Sum or Average         0.00 0.00 0.00 0.00 0.00        
Minimum of Months 397.10   273.67   0.00 0.00 0.00 0.00 0.00 0.00   6.44  
Maximum of Months 397.10   273.67   0.00 0.00 0.00 0.00 0.00 34.61   35.96  



Table of Contents

Report: PeakSpaceGainsMonthly

For: G CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 397.10 01-JAN-00:10 273.67 01-JAN-00:10 117.25 01-JAN-07:10 0.00 0.00 0.00 0.00 667.65 31-JAN-17:01 11109.79 01-JAN-07:01
February 397.10 01-FEB-00:10 273.67 01-FEB-00:10 117.25 01-FEB-07:10 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 10400.84 01-FEB-07:01
March 397.10 01-MAR-00:10 273.67 01-MAR-00:10 117.25 01-MAR-07:10 0.00 0.00 0.00 0.00 1072.67 16-MAR-16:01 11917.20 26-MAR-06:01
April 397.10 01-APR-00:10 273.67 01-APR-00:10 117.25 01-APR-06:10 0.00 0.00 0.00 0.00 3295.46 14-APR-16:01 8263.26 21-APR-06:01
May 397.10 01-MAY-00:10 273.67 01-MAY-00:10 117.25 01-MAY-06:10 0.00 0.00 0.00 0.00 4202.67 31-MAY-16:01 6380.04 01-MAY-06:01
June 397.10 01-JUN-00:10 273.67 01-JUN-00:10 117.25 01-JUN-06:10 0.00 0.00 0.00 0.00 6097.96 16-JUN-16:01 3834.68 21-JUN-06:01
July 397.10 01-JUL-00:10 273.67 01-JUL-00:10 117.25 01-JUL-06:10 0.00 0.00 0.00 0.00 4798.16 05-JUL-16:01 4187.57 01-JUL-06:01
August 397.10 01-AUG-00:10 273.67 01-AUG-00:10 117.25 01-AUG-06:10 0.00 0.00 0.00 0.00 5655.34 25-AUG-16:01 3921.75 24-AUG-06:01
September 397.10 01-SEP-00:10 273.67 01-SEP-00:10 117.25 01-SEP-06:10 0.00 0.00 0.00 0.00 4205.51 08-SEP-16:01 4942.25 22-SEP-06:01
October 397.10 01-OCT-00:10 273.67 01-OCT-00:10 117.25 01-OCT-06:10 0.00 0.00 0.00 0.00 2968.39 03-OCT-16:01 10676.52 25-OCT-06:01
November 397.10 01-NOV-00:10 273.67 01-NOV-00:10 117.25 01-NOV-06:10 0.00 0.00 0.00 0.00 106.26 01-NOV-15:00 13045.70 23-NOV-07:01
December 397.10 01-DEC-00:10 273.67 01-DEC-00:10 117.25 01-DEC-07:10 0.00 0.00 0.00 0.00 10.56 21-DEC-15:00 13128.03 05-DEC-07:01
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 397.10   273.67   117.25   0.00 0.00 0.00 0.00 0.00   3834.68  
Maximum of Months 397.10   273.67   117.25   0.00 0.00 0.00 0.00 6097.96   13128.03  



Table of Contents

Report: PeakSpaceGainsMonthly

For: M CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 397.10 01-JAN-00:10 273.67 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00 1.22 31-JAN-15:40 26.66 01-JAN-01:00
February 397.10 01-FEB-00:10 273.67 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 30.94 02-FEB-23:00
March 397.10 01-MAR-00:10 273.67 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00 2.34 15-MAR-15:00 25.19 28-MAR-04:00
April 397.10 01-APR-00:10 273.67 01-APR-00:10 0.00 0.00 0.00 0.00 0.00 13.37 30-APR-15:00 13.94 21-APR-06:00
May 397.10 01-MAY-00:10 273.67 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00 21.95 20-MAY-14:00 10.00 23-MAY-05:00
June 397.10 01-JUN-00:10 273.67 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00 28.92 19-JUN-14:00 5.51 13-JUN-06:00
July 397.10 01-JUL-00:10 273.67 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00 28.28 22-JUL-16:00 7.86 26-JUL-24:00
August 397.10 01-AUG-00:10 273.67 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00 22.56 13-AUG-16:00 14.00 28-AUG-16:52
September 397.10 01-SEP-00:10 273.67 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00 16.36 17-SEP-12:00 8.17 03-SEP-05:00
October 397.10 01-OCT-00:10 273.67 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00 11.01 10-OCT-15:00 23.74 22-OCT-14:00
November 397.10 01-NOV-00:10 273.67 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00 1.59 19-NOV-15:00 29.75 22-NOV-12:00
December 397.10 01-DEC-00:10 273.67 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00 0.23 21-DEC-15:00 22.68 07-DEC-08:00
                           
Annual Sum or Average         0.00 0.00 0.00 0.00 0.00        
Minimum of Months 397.10   273.67   0.00 0.00 0.00 0.00 0.00 0.00   5.51  
Maximum of Months 397.10   273.67   0.00 0.00 0.00 0.00 0.00 28.92   30.94  



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: G SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 5064.37 09-JAN-17:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 11.25
February 5049.57 24-FEB-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 27.06
March 4940.49 24-MAR-16:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 53.50
April 4975.46 18-APR-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 26.64
May 4827.78 11-MAY-07:32 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 2.27
June 4837.38 04-JUN-06:42 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 1.14 0.00
July 4781.84 06-JUL-06:52 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 0.00 0.31
August 4884.69 23-AUG-07:22 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 3.68
September 5032.43 20-SEP-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 1.91
October 5008.93 07-OCT-15:52 1187.50 98.19 2354.49 0.00 0.00 0.00 0.00 0.00 31.32
November 5113.97 17-NOV-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 40.79
December 5052.89 13-DEC-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 15.45
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 4781.84   0.00 50.50 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5113.97   2375.00 252.50 5297.60 0.00 0.00 0.00 0.00 1.14 53.50



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: G NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 4571.61 26-JAN-14:42 296.88 28.05 1913.02 0.00 0.00 0.00 0.00 0.00 0.44
February 2806.30 01-FEB-17:12 494.00 112.22 2354.49 0.00 0.00 0.00 0.00 0.00 43.95
March 4753.08 17-MAR-21:52 1425.00 101.00 2507.53 0.00 0.00 0.00 0.00 0.00 13.10
April 4793.84 16-APR-21:32 1425.00 101.00 2507.53 0.00 0.00 0.00 0.00 0.00 4.98
May 4717.55 11-MAY-08:62 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 0.00 0.93
June 4759.97 04-JUN-06:42 1211.25 109.41 2295.63 0.00 0.00 0.00 0.00 1.10 0.00
July 4666.85 06-JUL-07:12 555.75 50.50 2330.95 0.00 0.00 0.00 0.00 2.09 0.00
August 4690.56 23-AUG-08:12 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 4.79 0.00
September 4933.36 20-SEP-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 1.54
October 4878.41 21-OCT-21:52 1425.00 101.00 2507.53 0.00 0.00 0.00 0.00 0.00 31.29
November 4914.49 15-NOV-20:12 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 21.33
December 4724.20 27-DEC-19:02 1239.75 269.34 3284.51 0.00 0.00 0.00 0.00 0.00 11.44
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 2806.30   296.88 28.05 1913.02 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 4933.36   2018.75 269.34 3826.05 0.00 0.00 0.00 0.00 4.79 43.95



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: OFFICE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 6051.00 17-JAN-07:01 0.00 752.00 1949.81 0.00 0.00 0.00 0.00 0.00 46.05
February 1831.68 01-FEB-14:00 451.21 376.01 544.92 0.00 0.00 0.00 0.00 0.00 7.22
March 5678.92 21-MAR-06:01 0.00 752.00 1949.81 0.00 0.00 0.00 0.00 0.00 36.91
April 6268.73 17-APR-06:01 0.00 676.80 1754.83 0.00 0.00 0.00 0.00 0.00 19.05
May 6134.05 01-MAY-06:01 0.00 752.00 1949.81 0.00 0.00 0.00 0.00 0.00 30.51
June 6169.21 12-JUN-06:01 0.00 752.00 1949.81 0.00 0.00 0.00 0.00 0.00 14.22
July 6319.62 31-JUL-06:01 0.00 752.00 1949.81 0.00 0.00 0.00 0.00 0.00 10.04
August 6458.17 21-AUG-06:01 0.00 752.00 1949.81 0.00 0.00 0.00 0.00 0.00 12.04
September 6400.96 27-SEP-06:01 0.00 752.00 1949.81 0.00 0.00 0.00 0.00 0.00 24.44
October 6468.82 10-OCT-06:01 0.00 752.00 1949.81 0.00 0.00 0.00 0.00 0.00 27.70
November 6348.38 16-NOV-07:01 0.00 752.00 1949.81 0.00 0.00 0.00 0.00 0.00 33.11
December 6255.40 26-DEC-07:01 0.00 752.00 1949.81 0.00 0.00 0.00 0.00 0.00 40.79
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 1831.68   0.00 376.01 544.92 0.00 0.00 0.00 0.00 0.00 7.22
Maximum of Months 6468.82   451.21 752.00 1949.81 0.00 0.00 0.00 0.00 0.00 46.05



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: G NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 4296.74 28-JAN-21:02 1425.00 185.17 3001.98 0.00 0.00 0.00 0.00 0.00 20.70
February 1242.61 01-FEB-17:12 494.00 112.22 2354.49 0.00 0.00 0.00 0.00 0.00 43.78
March 4452.76 18-MAR-11:32 356.25 33.66 2436.90 0.00 0.00 0.00 0.00 0.40 0.00
April 4524.62 18-APR-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 26.08
May 4437.08 11-MAY-08:62 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 0.00 1.68
June 4450.63 04-JUN-06:42 1211.25 109.41 2295.63 0.00 0.00 0.00 0.00 0.92 0.00
July 4356.28 06-JUL-07:12 555.75 50.50 2330.95 0.00 0.00 0.00 0.00 1.97 0.00
August 4385.51 23-AUG-08:12 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 4.61 0.00
September 4595.78 20-SEP-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 1.59
October 4566.13 21-OCT-21:52 1425.00 101.00 2507.53 0.00 0.00 0.00 0.00 0.00 31.53
November 4565.11 15-NOV-20:12 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 20.59
December 4397.25 27-DEC-19:02 1239.75 269.34 3284.51 0.00 0.00 0.00 0.00 0.00 11.23
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 1242.61   356.25 33.66 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 4595.78   2018.75 269.34 3826.05 0.00 0.00 0.00 0.00 4.61 43.78



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: G N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 3841.75 20-JAN-20:42 1033.12 224.45 2619.37 0.00 0.00 0.00 0.00 0.00 1.42
February 2309.28 01-FEB-17:12 494.00 112.22 2354.49 0.00 0.00 0.00 0.00 0.00 26.47
March 3851.35 17-MAR-21:52 1425.00 101.00 2507.53 0.00 0.00 0.00 0.00 0.00 8.65
April 3946.08 18-APR-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 16.12
May 3808.33 11-MAY-08:62 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 0.00 0.77
June 3833.36 04-JUN-06:42 1211.25 109.41 2295.63 0.00 0.00 0.00 0.00 0.50 0.00
July 3759.08 06-JUL-07:12 555.75 50.50 2330.95 0.00 0.00 0.00 0.00 1.09 0.00
August 3774.16 23-AUG-08:12 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 2.68 0.00
September 3956.60 20-SEP-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 0.95
October 3951.22 21-OCT-21:52 1425.00 101.00 2507.53 0.00 0.00 0.00 0.00 0.00 19.45
November 3962.87 15-NOV-20:12 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 12.86
December 3827.58 27-DEC-19:02 1239.75 269.34 3284.51 0.00 0.00 0.00 0.00 0.00 6.97
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 2309.28   356.25 33.66 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 3962.87   2018.75 269.34 3826.05 0.00 0.00 0.00 0.00 2.68 26.47



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: G N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 3835.90 20-JAN-20:42 1033.12 224.45 2619.37 0.00 0.00 0.00 0.00 0.00 1.42
February 2307.65 01-FEB-17:12 494.00 112.22 2354.49 0.00 0.00 0.00 0.00 0.00 26.47
March 3845.71 17-MAR-21:52 1425.00 101.00 2507.53 0.00 0.00 0.00 0.00 0.00 8.65
April 3940.28 18-APR-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 16.12
May 3803.28 11-MAY-08:62 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 0.00 0.78
June 3827.68 04-JUN-06:42 1211.25 109.41 2295.63 0.00 0.00 0.00 0.00 0.50 0.00
July 3753.41 06-JUL-07:12 555.75 50.50 2330.95 0.00 0.00 0.00 0.00 1.09 0.00
August 3768.46 23-AUG-08:12 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 2.68 0.00
September 3950.54 20-SEP-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 0.95
October 3945.45 21-OCT-21:52 1425.00 101.00 2507.53 0.00 0.00 0.00 0.00 0.00 19.46
November 3965.27 15-NOV-20:12 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 12.74
December 3821.46 27-DEC-19:02 1239.75 269.34 3284.51 0.00 0.00 0.00 0.00 0.00 6.96
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 2307.65   356.25 33.66 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 3965.27   2018.75 269.34 3826.05 0.00 0.00 0.00 0.00 2.68 26.47



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: G S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 4093.99 09-JAN-17:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 6.88
February 4092.25 24-FEB-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 16.53
March 4017.41 24-MAR-16:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 33.62
April 4035.72 18-APR-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 16.59
May 3913.90 11-MAY-07:32 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 1.61
June 3908.22 04-JUN-06:42 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 0.50 0.00
July 3869.88 06-JUL-06:52 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 0.00 0.38
August 3947.32 23-AUG-07:22 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 2.52
September 4048.60 20-SEP-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 1.24
October 4028.91 11-OCT-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 22.02
November 4136.99 17-NOV-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 24.85
December 4085.53 13-DEC-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 9.32
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 3869.88   0.00 50.50 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 4136.99   2375.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.50 33.62



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: G S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 4175.55 09-JAN-17:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 6.87
February 4172.58 24-FEB-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 16.48
March 4098.21 24-MAR-16:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 33.63
April 4122.41 18-APR-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 16.75
May 3996.56 11-MAY-07:32 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 1.61
June 3994.24 04-JUN-06:42 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 0.47 0.00
July 3949.39 06-JUL-06:52 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 0.00 0.36
August 4028.44 23-AUG-07:22 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 2.49
September 4135.95 20-SEP-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 1.25
October 4121.93 07-OCT-15:52 1187.50 98.19 2354.49 0.00 0.00 0.00 0.00 0.00 18.94
November 4218.63 17-NOV-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 24.82
December 4165.21 13-DEC-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 9.28
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 3949.39   0.00 50.50 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 4218.63   2375.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.47 33.63



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: M SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 5742.47 09-JAN-17:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 16.15
February 5758.08 24-FEB-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 41.15
March 5665.84 11-MAR-18:52 1425.00 227.25 3531.74 0.00 0.00 0.00 0.00 0.00 49.23
April 5629.00 18-APR-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 38.51
May 5455.88 11-MAY-07:32 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 3.30
June 5459.52 04-JUN-06:42 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 2.01 0.00
July 5405.98 12-JUL-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 47.93 0.00
August 5501.78 23-AUG-07:22 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 4.89
September 5668.16 20-SEP-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 1.82
October 5655.00 23-OCT-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 8.33
November 5783.47 17-NOV-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 58.43
December 5714.79 13-DEC-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 22.43
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 5405.98   0.00 50.50 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5783.47   2375.00 252.50 5297.60 0.00 0.00 0.00 0.00 47.93 58.43



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: M NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 5436.06 09-JAN-20:02 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 22.68
February 5474.18 22-FEB-20:32 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 36.65
March 5552.70 11-MAR-18:52 1239.75 227.25 3531.74 0.00 0.00 0.00 0.00 0.00 48.39
April 5447.05 18-APR-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 37.59
May 5356.97 11-MAY-08:62 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 0.00 1.64
June 5391.14 04-JUN-06:42 1211.25 109.41 2295.63 0.00 0.00 0.00 0.00 1.85 0.00
July 5283.35 06-JUL-07:12 555.75 50.50 2330.95 0.00 0.00 0.00 0.00 3.32 0.00
August 5293.14 23-AUG-08:12 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 7.36 0.00
September 5580.59 20-SEP-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 1.19
October 5499.41 21-OCT-20:02 1425.00 185.17 3001.98 0.00 0.00 0.00 0.00 0.00 13.42
November 5532.32 15-NOV-20:12 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 29.89
December 5335.54 27-DEC-19:02 1239.75 269.34 3284.51 0.00 0.00 0.00 0.00 0.00 16.25
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 5283.35   356.25 33.66 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5580.59   2018.75 269.34 3826.05 0.00 0.00 0.00 0.00 7.36 48.39



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: M SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 5283.55 09-JAN-17:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 16.18
February 5305.20 24-FEB-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 41.23
March 5246.91 11-MAR-18:52 1425.00 227.25 3531.74 0.00 0.00 0.00 0.00 0.00 50.41
April 5199.88 18-APR-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 38.86
May 5065.35 11-MAY-07:32 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 3.57
June 5055.70 04-JUN-06:42 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 1.59 0.00
July 4994.30 06-JUL-06:52 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 0.00 0.44
August 5086.92 23-AUG-07:22 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 5.27
September 5223.93 20-SEP-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 1.93
October 5206.89 23-OCT-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 8.46
November 5326.45 17-NOV-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 58.56
December 5256.94 13-DEC-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 21.97
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 4994.30   0.00 50.50 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5326.45   2375.00 252.50 5297.60 0.00 0.00 0.00 0.00 1.59 58.56



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: M NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 5004.17 09-JAN-20:02 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 22.29
February 5042.47 22-FEB-20:32 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 35.91
March 5081.43 11-MAR-18:52 1239.75 227.25 3531.74 0.00 0.00 0.00 0.00 0.00 47.29
April 5110.91 18-APR-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 37.86
May 4971.89 11-MAY-08:62 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 0.00 2.29
June 4985.74 04-JUN-06:42 1211.25 109.41 2295.63 0.00 0.00 0.00 0.00 1.52 0.00
July 4877.99 06-JUL-07:12 555.75 50.50 2330.95 0.00 0.00 0.00 0.00 3.03 0.00
August 4903.70 23-AUG-08:12 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 6.83 0.00
September 5137.24 20-SEP-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 1.29
October 5076.14 21-OCT-20:02 1425.00 185.17 3001.98 0.00 0.00 0.00 0.00 0.00 13.75
November 5084.32 15-NOV-20:12 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 28.81
December 4911.24 27-DEC-19:02 1239.75 269.34 3284.51 0.00 0.00 0.00 0.00 0.00 15.96
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 4877.99   356.25 33.66 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5137.24   2018.75 269.34 3826.05 0.00 0.00 0.00 0.00 6.83 47.29



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: M N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 4361.10 09-JAN-20:02 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 13.91
February 4391.19 22-FEB-20:32 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 22.32
March 4432.24 11-MAR-18:52 1239.75 227.25 3531.74 0.00 0.00 0.00 0.00 0.00 29.11
April 4424.34 18-APR-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 23.25
May 4269.72 11-MAY-08:62 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 0.00 1.14
June 4293.68 04-JUN-06:42 1211.25 109.41 2295.63 0.00 0.00 0.00 0.00 0.99 0.00
July 4203.83 06-JUL-07:12 555.75 50.50 2330.95 0.00 0.00 0.00 0.00 1.93 0.00
August 4212.08 23-AUG-08:12 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 4.30 0.00
September 4420.30 20-SEP-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 0.84
October 4398.96 21-OCT-21:52 1425.00 101.00 2507.53 0.00 0.00 0.00 0.00 0.00 27.00
November 4430.65 15-NOV-20:12 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 17.97
December 4279.93 27-DEC-19:02 1239.75 269.34 3284.51 0.00 0.00 0.00 0.00 0.00 9.99
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 4203.83   356.25 33.66 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 4432.24   2018.75 269.34 3826.05 0.00 0.00 0.00 0.00 4.30 29.11



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: M N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 4353.34 09-JAN-20:02 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 13.90
February 4383.75 22-FEB-20:32 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 22.30
March 4423.46 11-MAR-18:52 1239.75 227.25 3531.74 0.00 0.00 0.00 0.00 0.00 29.08
April 4417.04 18-APR-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 23.25
May 4263.26 11-MAY-08:62 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 0.00 1.16
June 4286.60 04-JUN-06:42 1211.25 109.41 2295.63 0.00 0.00 0.00 0.00 0.98 0.00
July 4196.71 06-JUL-07:12 555.75 50.50 2330.95 0.00 0.00 0.00 0.00 1.93 0.00
August 4205.41 23-AUG-08:12 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 4.29 0.00
September 4412.65 20-SEP-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 0.84
October 4392.59 21-OCT-21:52 1425.00 101.00 2507.53 0.00 0.00 0.00 0.00 0.00 27.03
November 4421.81 15-NOV-20:12 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 17.92
December 4272.33 27-DEC-19:02 1239.75 269.34 3284.51 0.00 0.00 0.00 0.00 0.00 9.98
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 4196.71   356.25 33.66 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 4423.46   2018.75 269.34 3826.05 0.00 0.00 0.00 0.00 4.29 29.08



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: M S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 4584.89 09-JAN-17:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 9.88
February 4606.95 24-FEB-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 25.05
March 4566.25 11-MAR-18:52 1425.00 227.25 3531.74 0.00 0.00 0.00 0.00 0.00 30.77
April 4509.88 18-APR-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 23.84
May 4370.50 11-MAY-07:32 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 2.25
June 4361.66 04-JUN-06:42 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 1.11 0.00
July 4321.26 06-JUL-06:52 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 0.00 0.43
August 4403.86 23-AUG-07:22 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 3.47
September 4511.50 20-SEP-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 1.24
October 4504.16 23-OCT-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 5.31
November 4623.74 17-NOV-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 35.63
December 4575.41 13-DEC-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 13.64
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 4321.26   0.00 50.50 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 4623.74   2375.00 252.50 5297.60 0.00 0.00 0.00 0.00 1.11 35.63



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: M S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 4577.99 09-JAN-17:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 9.88
February 4600.03 24-FEB-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 25.05
March 4558.68 11-MAR-18:52 1425.00 227.25 3531.74 0.00 0.00 0.00 0.00 0.00 30.76
April 4503.38 18-APR-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 23.85
May 4364.54 11-MAY-07:32 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 2.26
June 4355.33 04-JUN-06:42 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 1.11 0.00
July 4314.92 06-JUL-06:52 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 0.00 0.43
August 4397.56 23-AUG-07:22 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 3.48
September 4504.68 20-SEP-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 1.24
October 4497.86 23-OCT-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 5.31
November 4616.84 17-NOV-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 35.63
December 4568.54 13-DEC-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 13.64
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 4314.92   0.00 50.50 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 4616.84   2375.00 252.50 5297.60 0.00 0.00 0.00 0.00 1.11 35.63



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: T SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 6592.01 09-JAN-17:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 21.31
February 6600.54 24-FEB-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 54.30
March 6464.88 02-MAR-17:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 53.06
April 6408.12 06-APR-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 32.80
May 6170.86 11-MAY-07:32 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 2.42
June 6225.49 04-JUN-06:42 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 3.88 0.00
July 6263.74 12-JUL-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 63.16 0.00
August 6208.28 23-AUG-07:22 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 1.84
September 6489.89 20-SEP-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 1.38
October 6520.68 23-OCT-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 11.05
November 6632.98 17-NOV-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 77.04
December 6542.86 13-DEC-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 29.55
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 6170.86   0.00 50.50 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 6632.98   2375.00 252.50 5297.60 0.00 0.00 0.00 0.00 63.16 77.04



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: T NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 5288.78 07-JAN-22:52 1187.50 84.17 2089.61 0.00 0.00 0.00 0.00 0.00 32.81
February 5233.03 22-FEB-20:32 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 47.02
March 6360.35 11-MAR-18:52 1239.75 227.25 3531.74 0.00 0.00 0.00 0.00 0.00 62.32
April 6286.75 06-APR-17:32 1239.75 227.25 3531.74 0.00 0.00 0.00 0.00 0.00 76.96
May 6171.90 11-MAY-08:62 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 0.00 1.66
June 6225.78 04-JUN-06:42 1211.25 109.41 2295.63 0.00 0.00 0.00 0.00 3.07 0.00
July 6097.15 06-JUL-07:12 555.75 50.50 2330.95 0.00 0.00 0.00 0.00 5.23 0.00
August 6118.51 23-AUG-08:12 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 10.29 0.00
September 6441.45 20-SEP-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 0.94
October 6347.85 21-OCT-20:02 1425.00 185.17 3001.98 0.00 0.00 0.00 0.00 0.00 17.05
November 6368.26 15-NOV-20:12 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 38.58
December 2079.69 24-DEC-14:43 237.50 22.44 1530.42 0.00 0.00 0.00 0.00 0.00 0.64
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 2079.69   237.50 22.44 1530.42 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 6441.45   2018.75 269.34 3826.05 0.00 0.00 0.00 0.00 10.29 76.96



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: T SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 5933.43 09-JAN-17:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 21.37
February 5948.84 13-FEB-17:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 56.86
March 5840.11 11-MAR-18:52 1425.00 227.25 3531.74 0.00 0.00 0.00 0.00 0.00 66.01
April 5843.99 16-APR-10:52 712.50 33.66 2472.22 0.00 0.00 0.00 0.00 0.00 41.97
May 5673.40 13-MAY-09:42 1425.00 33.66 2436.90 0.00 0.00 0.00 0.00 0.00 4.83
June 5655.44 04-JUN-06:42 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 2.40 0.00
July 5644.66 12-JUL-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 62.24 0.00
August 5654.80 23-AUG-07:22 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 6.10
September 5845.14 20-SEP-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 1.58
October 5862.25 23-OCT-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 11.27
November 5966.19 17-NOV-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 77.29
December 5893.82 13-DEC-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 29.64
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 5644.66   0.00 33.66 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5966.19   2375.00 252.50 5297.60 0.00 0.00 0.00 0.00 62.24 77.29



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: T NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 5406.79 26-JAN-14:42 296.88 28.05 1913.02 0.00 0.00 0.00 0.00 0.00 1.63
February 2940.80 18-FEB-19:12 1239.75 269.34 3284.51 0.00 0.00 0.00 0.00 0.00 40.16
March 5699.89 18-MAR-11:32 356.25 33.66 2436.90 0.00 0.00 0.00 0.00 0.00 1.17
April 5782.52 16-APR-12:02 356.25 33.66 2330.95 0.00 0.00 0.00 0.00 0.00 19.40
May 5728.34 13-MAY-10:12 356.25 33.66 2472.22 0.00 0.00 0.00 0.00 0.00 8.43
June 5641.95 04-JUN-06:42 1211.25 109.41 2295.63 0.00 0.00 0.00 0.00 2.35 0.00
July 5516.98 06-JUL-07:12 555.75 50.50 2330.95 0.00 0.00 0.00 0.00 4.41 0.00
August 5552.93 23-AUG-08:12 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 9.30 0.00
September 5797.08 20-SEP-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 1.14
October 5736.29 21-OCT-20:02 1425.00 185.17 3001.98 0.00 0.00 0.00 0.00 0.00 17.69
November 5738.68 01-NOV-19:52 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 17.81
December 2562.31 24-DEC-14:43 237.50 22.44 1530.42 0.00 0.00 0.00 0.00 0.00 0.74
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 2562.31   237.50 22.44 1530.42 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5797.08   2018.75 269.34 3826.05 0.00 0.00 0.00 0.00 9.30 40.16



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: T N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 4473.96 07-JAN-22:52 1187.50 84.17 2089.61 0.00 0.00 0.00 0.00 0.00 19.69
February 3705.34 22-FEB-20:32 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 28.27
March 5155.20 17-MAR-21:52 1425.00 101.00 2507.53 0.00 0.00 0.00 0.00 0.00 19.24
April 5119.23 16-APR-21:32 1425.00 101.00 2507.53 0.00 0.00 0.00 0.00 0.00 5.84
May 5054.07 11-MAY-08:62 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 0.00 1.60
June 5085.12 04-JUN-06:42 1211.25 109.41 2295.63 0.00 0.00 0.00 0.00 1.39 0.00
July 4978.55 06-JUL-07:12 555.75 50.50 2330.95 0.00 0.00 0.00 0.00 2.73 0.00
August 4994.33 23-AUG-08:12 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 5.64 0.00
September 5230.64 20-SEP-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 0.88
October 5214.32 21-OCT-21:52 1425.00 101.00 2507.53 0.00 0.00 0.00 0.00 0.00 35.67
November 5199.68 01-NOV-19:52 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 11.00
December 1473.61 23-DEC-20:12 826.50 179.56 2095.50 0.00 0.00 0.00 0.00 0.00 21.01
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 1473.61   356.25 33.66 2089.61 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5230.64   2018.75 269.34 3826.05 0.00 0.00 0.00 0.00 5.64 35.67



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: T N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 4730.35 28-JAN-14:42 296.88 28.05 1913.02 0.00 0.00 0.00 0.00 0.00 0.58
February 3757.11 18-FEB-19:12 1239.75 269.34 3284.51 0.00 0.00 0.00 0.00 0.00 24.26
March 5140.99 18-MAR-11:32 356.25 33.66 2436.90 0.00 0.00 0.00 0.00 0.00 0.48
April 5100.93 16-APR-12:22 356.25 33.66 2330.95 0.00 0.00 0.00 0.00 0.00 5.74
May 5036.60 11-MAY-08:62 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 0.00 1.67
June 5066.38 04-JUN-06:42 1211.25 109.41 2295.63 0.00 0.00 0.00 0.00 1.37 0.00
July 4959.74 06-JUL-07:12 555.75 50.50 2330.95 0.00 0.00 0.00 0.00 2.73 0.00
August 4976.58 23-AUG-08:12 356.25 33.66 2366.26 0.00 0.00 0.00 0.00 5.60 0.00
September 5210.23 20-SEP-06:01 2018.75 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 0.89
October 5195.34 21-OCT-21:52 1425.00 101.00 2507.53 0.00 0.00 0.00 0.00 0.00 35.70
November 5180.11 01-NOV-19:52 1239.75 269.34 3143.25 0.00 0.00 0.00 0.00 0.00 11.01
December 1474.08 24-DEC-14:43 237.50 22.44 1530.42 0.00 0.00 0.00 0.00 0.00 0.33
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 1474.08   237.50 22.44 1530.42 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5210.23   2018.75 269.34 3826.05 0.00 0.00 0.00 0.00 5.60 35.70



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: T S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 5388.03 09-JAN-17:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 13.03
February 5396.85 13-FEB-17:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 34.58
March 5314.75 11-MAR-18:52 1425.00 227.25 3531.74 0.00 0.00 0.00 0.00 0.00 40.29
April 5213.44 07-APR-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 12.35
May 5066.80 11-MAY-07:32 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 2.00
June 5097.74 04-JUN-06:42 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 1.89 0.00
July 5077.06 12-JUL-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 37.43 0.00
August 5094.68 23-AUG-07:22 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 2.16
September 5289.29 20-SEP-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 1.14
October 5306.36 23-OCT-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 7.00
November 5420.57 17-NOV-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 46.99
December 5355.04 13-DEC-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 18.03
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 5066.80   0.00 50.50 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5420.57   2375.00 252.50 5297.60 0.00 0.00 0.00 0.00 37.43 46.99



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: T S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 5368.21 09-JAN-17:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 13.03
February 5376.88 13-FEB-17:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 34.59
March 5294.54 11-MAR-18:52 1425.00 227.25 3531.74 0.00 0.00 0.00 0.00 0.00 40.28
April 5194.24 07-APR-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 12.37
May 5052.44 13-MAY-09:42 1425.00 33.66 2436.90 0.00 0.00 0.00 0.00 0.00 3.05
June 5079.10 04-JUN-06:42 1425.00 109.41 2295.63 0.00 0.00 0.00 0.00 1.87 0.00
July 5057.93 12-JUL-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 37.41 0.00
August 5075.96 23-AUG-07:22 0.00 50.50 2330.95 0.00 0.00 0.00 0.00 0.00 2.19
September 5269.02 20-SEP-06:01 2375.00 182.35 3826.05 0.00 0.00 0.00 0.00 0.00 1.14
October 5286.77 23-OCT-16:01 0.00 224.44 4708.98 0.00 0.00 0.00 0.00 0.00 7.01
November 5400.11 17-NOV-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 47.00
December 5334.60 13-DEC-17:01 0.00 252.50 5297.60 0.00 0.00 0.00 0.00 0.00 18.03
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 5052.44   0.00 33.66 2295.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5400.11   2375.00 252.50 5297.60 0.00 0.00 0.00 0.00 37.41 47.00



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: T CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 0.00 01-JAN-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 20.21
February 0.00 01-FEB-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 10.76
March 0.00 01-MAR-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 9.32
April 0.00 01-APR-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 8.91
May 0.00 01-MAY-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 4.40
June 0.00 01-JUN-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 0.24
July 0.00 01-JUL-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.87 0.00
August 0.00 01-AUG-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 2.01 0.00
September 0.00 01-SEP-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 0.01
October 0.00 01-OCT-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 0.75
November 0.00 01-NOV-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 4.96
December 0.00 01-DEC-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 9.37
                       
Annual Sum or Average         0.00 0.00 0.00 0.00 0.00    
Minimum of Months 0.00   397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00   397.10 273.67 0.00 0.00 0.00 0.00 0.00 2.01 20.21



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: G CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 0.00 01-JAN-00:10 397.10 273.67 40.13 0.00 0.00 0.00 0.00 0.00 11.50
February 0.00 01-FEB-00:10 397.10 273.67 40.13 0.00 0.00 0.00 0.00 0.00 6.38
March 0.00 01-MAR-00:10 397.10 273.67 40.13 0.00 0.00 0.00 0.00 0.00 5.28
April 0.00 01-APR-00:10 397.10 273.67 40.13 0.00 0.00 0.00 0.00 0.00 4.78
May 0.00 01-MAY-00:10 397.10 273.67 40.13 0.00 0.00 0.00 0.00 0.00 2.92
June 0.00 01-JUN-00:10 397.10 273.67 40.13 0.00 0.00 0.00 0.00 0.00 0.60
July 0.00 01-JUL-00:10 397.10 273.67 40.13 0.00 0.00 0.00 0.00 0.00 0.26
August 0.00 01-AUG-00:10 397.10 273.67 40.13 0.00 0.00 0.00 0.00 0.51 0.00
September 0.00 01-SEP-00:10 397.10 273.67 40.13 0.00 0.00 0.00 0.00 0.00 0.60
October 0.00 01-OCT-00:10 397.10 273.67 40.13 0.00 0.00 0.00 0.00 0.00 1.28
November 0.00 01-NOV-00:10 397.10 273.67 40.13 0.00 0.00 0.00 0.00 0.00 3.22
December 0.00 01-DEC-00:10 397.10 273.67 40.13 0.00 0.00 0.00 0.00 0.00 5.74
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 0.00   397.10 273.67 40.13 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00   397.10 273.67 40.13 0.00 0.00 0.00 0.00 0.51 11.50



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: M CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 0.00 01-JAN-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 16.91
February 0.00 01-FEB-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 8.87
March 0.00 01-MAR-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 7.92
April 0.00 01-APR-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 7.56
May 0.00 01-MAY-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 3.53
June 0.00 01-JUN-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 0.23
July 0.00 01-JUL-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.82 0.00
August 0.00 01-AUG-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 1.72 0.00
September 0.00 01-SEP-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 0.01
October 0.00 01-OCT-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 0.60
November 0.00 01-NOV-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 4.19
December 0.00 01-DEC-00:10 397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 7.97
                       
Annual Sum or Average         0.00 0.00 0.00 0.00 0.00    
Minimum of Months 0.00   397.10 273.67 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00   397.10 273.67 0.00 0.00 0.00 0.00 0.00 1.72 16.91



Table of Contents

Report: EnergyConsumptionElectricityNaturalGasMonthly

For: Meter

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum} [W] ELECTRICITY:FACILITY {TIMESTAMP} NATURALGAS:FACILITY [J] NATURALGAS:FACILITY {Maximum} [W] NATURALGAS:FACILITY {TIMESTAMP}
January 0.562750E+11 48606.83 31-JAN-17:10 0.318673E+11 23106.97 22-JAN-07:49
February 0.468922E+11 40826.87 01-FEB-17:19 0.285438E+11 23082.06 01-FEB-07:19
March 0.540720E+11 48954.21 16-MAR-16:10 0.301373E+11 22203.87 01-MAR-07:30
April 0.695027E+11 56688.67 14-APR-16:19 0.269019E+11 20845.56 03-APR-06:00
May 0.774714E+11 57517.48 18-MAY-16:19 0.253268E+11 19037.01 01-MAY-06:30
June 0.881385E+11 65237.17 28-JUN-16:19 0.225534E+11 17306.16 01-JUN-06:19
July 0.917280E+11 61523.22 21-JUL-16:19 0.223287E+11 15890.72 01-JUL-06:30
August 0.897445E+11 64630.62 25-AUG-16:19 0.226292E+11 16677.75 30-AUG-06:19
September 0.830266E+11 62129.23 08-SEP-16:19 0.233451E+11 17553.50 30-SEP-06:30
October 0.686086E+11 58307.47 03-OCT-16:19 0.264440E+11 19568.72 31-OCT-06:00
November 0.562210E+11 52959.22 01-NOV-16:19 0.280012E+11 21227.91 30-NOV-07:40
December 0.545446E+11 44157.44 22-DEC-17:10 0.309344E+11 22940.19 29-DEC-07:40
             
Annual Sum or Average 0.836225E+12     0.319013E+12    
Minimum of Months 0.468922E+11 40826.87   0.223287E+11 15890.72  
Maximum of Months 0.917280E+11 65237.17   0.318673E+11 23106.97  



Table of Contents

Report: EnergyConsumptionElectricityGeneratedPropaneMonthly

For: Meter

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ELECTRICITYPRODUCED:FACILITY [J] ELECTRICITYPRODUCED:FACILITY {Maximum} [W] ELECTRICITYPRODUCED:FACILITY {TIMESTAMP} PROPANE:FACILITY [] PROPANE:FACILITY []
January 0.489010E+10 8172.48 30-JAN-12:30 0.00 0.00
February 0.438106E+10 10290.05 27-FEB-12:39 0.00 0.00
March 0.641412E+10 11861.89 28-MAR-12:30 0.00 0.00
April 0.911998E+10 11968.55 19-APR-12:30 0.00 0.00
May 0.100860E+11 12168.93 12-MAY-12:30 0.00 0.00
June 0.100572E+11 11816.79 10-JUN-12:30 0.00 0.00
July 0.853807E+10 11219.99 21-JUL-12:30 0.00 0.00
August 0.784545E+10 11012.64 05-AUG-12:30 0.00 0.00
September 0.634734E+10 10523.64 09-SEP-12:30 0.00 0.00
October 0.607568E+10 10081.88 12-OCT-12:30 0.00 0.00
November 0.464108E+10 8647.18 04-NOV-11:00 0.00 0.00
December 0.429721E+10 7567.10 14-DEC-12:30 0.00 0.00
           
Annual Sum or Average 0.826934E+11     0.00 0.00
Minimum of Months 0.429721E+10 7567.10   0.00 0.00
Maximum of Months 0.100860E+11 12168.93   0.00 0.00



Table of Contents

Report: EndUseEnergyConsumptionElectricityMonthly

For: Meter

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

INTERIORLIGHTS:ELECTRICITY [J] EXTERIORLIGHTS:ELECTRICITY [J] INTERIOREQUIPMENT:ELECTRICITY [J] EXTERIOREQUIPMENT:ELECTRICITY [] FANS:ELECTRICITY [J] PUMPS:ELECTRICITY [J] HEATING:ELECTRICITY [J] COOLING:ELECTRICITY [J] HEATREJECTION:ELECTRICITY [] HUMIDIFIER:ELECTRICITY [] HEATRECOVERY:ELECTRICITY [J] WATERSYSTEMS:ELECTRICITY [] COGENERATION:ELECTRICITY [J]
January 0.456285E+10 0.223585E+10 0.359601E+11 0.00 0.684653E+10 34626425.15 0.221532E+09 0.641351E+10 0.00 0.00 0.00 0.00 0.00
February 0.413026E+10 0.191793E+10 0.324930E+11 0.00 0.527774E+10 31275480.78 0.151284E+09 0.289071E+10 0.00 0.00 0.00 0.00 0.00
March 0.459163E+10 0.197193E+10 0.360016E+11 0.00 0.635278E+10 34626425.15 0.204969E+09 0.491441E+10 0.00 0.00 0.00 0.00 0.00
April 0.442185E+10 0.175331E+10 0.348090E+11 0.00 0.102532E+11 33509443.69 0.00 0.182318E+11 0.00 0.00 0.00 0.00 0.00
May 0.458204E+10 0.167841E+10 0.359878E+11 0.00 0.118989E+11 34626425.15 0.00 0.232896E+11 0.00 0.00 0.00 0.00 0.00
June 0.444104E+10 0.156866E+10 0.348367E+11 0.00 0.143248E+11 33509443.69 0.00 0.329338E+11 0.00 0.00 0.00 0.00 0.00
July 0.456285E+10 0.164183E+10 0.359601E+11 0.00 0.148059E+11 34626425.15 0.00 0.347227E+11 0.00 0.00 0.00 0.00 0.00
August 0.459163E+10 0.175157E+10 0.360016E+11 0.00 0.142836E+11 34626425.15 0.00 0.330814E+11 0.00 0.00 0.00 0.00 0.00
September 0.442185E+10 0.183954E+10 0.348090E+11 0.00 0.130346E+11 33509443.69 0.00 0.288881E+11 0.00 0.00 0.00 0.00 0.00
October 0.457244E+10 0.206252E+10 0.359739E+11 0.00 0.968745E+10 34626425.15 3761007.65 0.162739E+11 0.00 0.00 0.00 0.00 0.00
November 0.442185E+10 0.213133E+10 0.348090E+11 0.00 0.701852E+10 33509443.69 0.156675E+09 0.765006E+10 0.00 0.00 0.00 0.00 0.00
December 0.456285E+10 0.227853E+10 0.359601E+11 0.00 0.634341E+10 34626425.15 0.107717E+10 0.428790E+10 0.00 0.00 0.00 0.00 0.00
                           
Annual Sum or Average 0.538631E+11 0.228314E+11 0.423602E+12 0.00 0.120127E+12 0.407698E+09 0.181540E+10 0.213578E+12 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.413026E+10 0.156866E+10 0.324930E+11 0.00 0.527774E+10 31275480.78 0.00 0.289071E+10 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.459163E+10 0.227853E+10 0.360016E+11 0.00 0.148059E+11 34626425.15 0.107717E+10 0.347227E+11 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: EndUseEnergyConsumptionNaturalGasMonthly

For: Meter

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

INTERIOREQUIPMENT:NATURALGAS [] EXTERIOREQUIPMENT:NATURALGAS [] HEATING:NATURALGAS [] COOLING:NATURALGAS [] WATERSYSTEMS:NATURALGAS [J] COGENERATION:NATURALGAS [] HUMIDIFIER:NATURALGAS []
January 0.00 0.00 0.00 0.00 0.318673E+11 0.00 0.00
February 0.00 0.00 0.00 0.00 0.285438E+11 0.00 0.00
March 0.00 0.00 0.00 0.00 0.301373E+11 0.00 0.00
April 0.00 0.00 0.00 0.00 0.269019E+11 0.00 0.00
May 0.00 0.00 0.00 0.00 0.253268E+11 0.00 0.00
June 0.00 0.00 0.00 0.00 0.225534E+11 0.00 0.00
July 0.00 0.00 0.00 0.00 0.223287E+11 0.00 0.00
August 0.00 0.00 0.00 0.00 0.226292E+11 0.00 0.00
September 0.00 0.00 0.00 0.00 0.233451E+11 0.00 0.00
October 0.00 0.00 0.00 0.00 0.264440E+11 0.00 0.00
November 0.00 0.00 0.00 0.00 0.280012E+11 0.00 0.00
December 0.00 0.00 0.00 0.00 0.309344E+11 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.319013E+12 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.223287E+11 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.318673E+11 0.00 0.00



Table of Contents

Report: PeakEnergyEndUseElectricityPart1Monthly

For: Meter

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

INTERIORLIGHTS:ELECTRICITY {Maximum} [W] INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} EXTERIOREQUIPMENT:ELECTRICITY [] FANS:ELECTRICITY {Maximum} [W] FANS:ELECTRICITY {TIMESTAMP} PUMPS:ELECTRICITY {Maximum} [W] PUMPS:ELECTRICITY {TIMESTAMP} HEATING:ELECTRICITY {Maximum} [W] HEATING:ELECTRICITY {TIMESTAMP}
January 2561.45 01-JAN-19:10 1451.66 01-JAN-00:10 20787.24 03-JAN-17:10 0.00 7531.54 31-JAN-17:10 12.93 01-JAN-07:10 4505.53 01-JAN-05:00
February 2561.45 01-FEB-19:10 1451.66 01-FEB-00:10 20787.24 01-FEB-17:10 0.00 5764.02 01-FEB-17:19 12.93 01-FEB-07:10 977.69 05-FEB-04:00
March 2561.45 01-MAR-19:10 1451.66 01-MAR-00:10 20787.24 01-MAR-17:10 0.00 7529.46 16-MAR-16:10 12.93 01-MAR-07:10 3210.08 26-MAR-05:00
April 2561.45 01-APR-18:10 1451.66 01-APR-00:10 20787.24 03-APR-16:10 0.00 9195.25 14-APR-16:19 12.93 02-APR-06:10 0.00 01-APR-00:10
May 2561.45 01-MAY-18:10 1451.66 01-MAY-00:10 20787.24 01-MAY-16:10 0.00 9422.17 18-MAY-16:19 12.93 01-MAY-06:10 0.00 01-MAY-00:10
June 2561.45 01-JUN-18:10 1451.66 01-JUN-00:10 20787.24 01-JUN-16:10 0.00 10972.24 16-JUN-16:19 12.93 01-JUN-06:10 0.00 01-JUN-00:10
July 2561.45 01-JUL-18:10 1451.66 01-JUL-00:10 20787.24 03-JUL-16:10 0.00 9874.04 05-JUL-16:19 12.93 03-JUL-06:10 0.00 01-JUL-00:10
August 2561.45 01-AUG-18:10 1451.66 01-AUG-00:10 20787.24 01-AUG-16:10 0.00 10840.78 25-AUG-16:19 12.93 01-AUG-06:10 0.00 01-AUG-00:10
September 2561.45 01-SEP-18:10 1451.66 01-SEP-00:10 20787.24 01-SEP-16:10 0.00 9997.84 28-SEP-16:19 12.93 01-SEP-06:10 0.00 01-SEP-00:10
October 2561.45 01-OCT-18:10 1451.66 01-OCT-00:10 20787.24 02-OCT-16:10 0.00 9440.18 06-OCT-16:19 12.93 02-OCT-06:10 202.50 26-OCT-05:00
November 2561.45 01-NOV-18:10 1451.66 01-NOV-00:10 20787.24 01-NOV-16:10 0.00 8395.49 01-NOV-16:19 12.93 02-NOV-06:10 2789.32 24-NOV-05:00
December 2561.45 01-DEC-19:10 1451.66 01-DEC-00:10 20787.24 01-DEC-17:10 0.00 6585.42 22-DEC-17:10 12.93 01-DEC-07:10 4359.85 07-DEC-05:00
                           
Annual Sum or Average             0.00            
Minimum of Months 2561.45   1451.66   20787.24   0.00 5764.02   12.93   0.00  
Maximum of Months 2561.45   1451.66   20787.24   0.00 10972.24   12.93   4505.53  



Table of Contents

Report: PeakEnergyEndUseElectricityPart2Monthly

For: Meter

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING:ELECTRICITY {Maximum} [W] COOLING:ELECTRICITY {TIMESTAMP} HEATREJECTION:ELECTRICITY [] HUMIDIFIER:ELECTRICITY [] HEATRECOVERY:ELECTRICITY {Maximum} [W] HEATRECOVERY:ELECTRICITY {TIMESTAMP} WATERSYSTEMS:ELECTRICITY [] COGENERATION:ELECTRICITY {Maximum} [W] COGENERATION:ELECTRICITY {TIMESTAMP}
January 18235.53 31-JAN-17:10 0.00 0.00 0.00 01-JAN-00:10 0.00 0.00 01-JAN-00:10
February 12223.09 01-FEB-17:19 0.00 0.00 0.00 01-FEB-00:10 0.00 0.00 01-FEB-00:10
March 18584.99 16-MAR-16:10 0.00 0.00 0.00 01-MAR-00:10 0.00 0.00 01-MAR-00:10
April 24653.67 14-APR-16:19 0.00 0.00 0.00 01-APR-00:10 0.00 0.00 01-APR-00:10
May 25255.56 18-MAY-16:19 0.00 0.00 0.00 01-MAY-00:10 0.00 0.00 01-MAY-00:10
June 31651.86 28-JUN-16:19 0.00 0.00 0.00 01-JUN-00:10 0.00 0.00 01-JUN-00:10
July 28913.08 21-JUL-16:19 0.00 0.00 0.00 01-JUL-00:10 0.00 0.00 01-JUL-00:10
August 30950.09 25-AUG-16:19 0.00 0.00 0.00 01-AUG-00:10 0.00 0.00 01-AUG-00:10
September 29359.42 08-SEP-16:19 0.00 0.00 0.00 01-SEP-00:10 0.00 0.00 01-SEP-00:10
October 26315.30 03-OCT-16:19 0.00 0.00 0.00 01-OCT-00:10 0.00 0.00 01-OCT-00:10
November 21733.14 01-NOV-16:10 0.00 0.00 0.00 01-NOV-00:10 0.00 0.00 01-NOV-00:10
December 14732.26 22-DEC-17:10 0.00 0.00 0.00 01-DEC-00:10 0.00 0.00 01-DEC-00:10
                   
Annual Sum or Average     0.00 0.00     0.00    
Minimum of Months 12223.09   0.00 0.00 0.00   0.00 0.00  
Maximum of Months 31651.86   0.00 0.00 0.00   0.00 0.00  



Table of Contents

Report: ElectricComponentsOfPeakDemandMonthly

For: Meter

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ELECTRICITY:FACILITY {Maximum} [W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [] FANS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY []
January 48606.83 31-JAN-17:10 2039.59 20787.24 0.00 0.00 7531.54 12.93 0.00 18235.53 0.00
February 40826.87 01-FEB-17:19 2039.59 20787.24 0.00 0.00 5764.02 12.93 0.00 12223.09 0.00
March 48954.21 16-MAR-16:10 2039.59 20787.24 0.00 0.00 7529.46 12.93 0.00 18584.99 0.00
April 56688.67 14-APR-16:19 2039.59 20787.24 0.00 0.00 9195.25 12.93 0.00 24653.67 0.00
May 57517.48 18-MAY-16:19 2039.59 20787.24 0.00 0.00 9422.17 12.93 0.00 25255.56 0.00
June 65237.17 28-JUN-16:19 2039.59 20787.24 0.00 0.00 10745.55 12.93 0.00 31651.86 0.00
July 61523.22 21-JUL-16:19 2039.59 20787.24 0.00 0.00 9770.39 12.93 0.00 28913.08 0.00
August 64630.62 25-AUG-16:19 2039.59 20787.24 0.00 0.00 10840.78 12.93 0.00 30950.09 0.00
September 62129.23 08-SEP-16:19 2039.59 20787.24 0.00 0.00 9930.05 12.93 0.00 29359.42 0.00
October 58307.47 03-OCT-16:19 2039.59 20787.24 0.00 0.00 9152.41 12.93 0.00 26315.30 0.00
November 52959.22 01-NOV-16:19 2039.59 20787.24 0.00 0.00 8395.49 12.93 0.00 21723.97 0.00
December 44157.44 22-DEC-17:10 2039.59 20787.24 0.00 0.00 6585.42 12.93 0.00 14732.26 0.00
                       
Annual Sum or Average           0.00         0.00
Minimum of Months 40826.87   2039.59 20787.24 0.00 0.00 5764.02 12.93 0.00 12223.09 0.00
Maximum of Months 65237.17   2039.59 20787.24 0.00 0.00 10840.78 12.93 0.00 31651.86 0.00



Table of Contents

Report: PeakEnergyEndUseNaturalGasMonthly

For: Meter

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

INTERIOREQUIPMENT:NATURALGAS [] EXTERIOREQUIPMENT:NATURALGAS [] HEATING:NATURALGAS [] COOLING:NATURALGAS [] WATERSYSTEMS:NATURALGAS {Maximum} [W] WATERSYSTEMS:NATURALGAS {TIMESTAMP} COGENERATION:NATURALGAS []
January 0.00 0.00 0.00 0.00 23106.97 22-JAN-07:49 0.00
February 0.00 0.00 0.00 0.00 23082.06 01-FEB-07:19 0.00
March 0.00 0.00 0.00 0.00 22203.87 01-MAR-07:30 0.00
April 0.00 0.00 0.00 0.00 20845.56 03-APR-06:00 0.00
May 0.00 0.00 0.00 0.00 19037.01 01-MAY-06:30 0.00
June 0.00 0.00 0.00 0.00 17306.16 01-JUN-06:19 0.00
July 0.00 0.00 0.00 0.00 15890.72 01-JUL-06:30 0.00
August 0.00 0.00 0.00 0.00 16677.75 30-AUG-06:19 0.00
September 0.00 0.00 0.00 0.00 17553.50 30-SEP-06:30 0.00
October 0.00 0.00 0.00 0.00 19568.72 31-OCT-06:00 0.00
November 0.00 0.00 0.00 0.00 21227.91 30-NOV-07:40 0.00
December 0.00 0.00 0.00 0.00 22940.19 29-DEC-07:40 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00     0.00
Minimum of Months 0.00 0.00 0.00 0.00 15890.72   0.00
Maximum of Months 0.00 0.00 0.00 0.00 23106.97   0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: G SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 1.50 24.57 0.00 24.57
May 0.00 0.00 0.00 0.00 1.83 24.59 0.00 24.59
June 0.00 0.00 0.00 0.00 3.67 24.66 0.00 24.66
July 0.00 0.00 0.00 0.00 2.83 24.61 0.00 24.61
August 0.00 0.00 0.00 0.00 2.50 24.65 0.00 24.65
September 0.00 0.00 0.00 0.00 3.00 24.65 0.00 24.65
October 0.00 0.00 0.00 0.00 1.83 24.63 0.00 24.63
November 0.00 0.00 0.00 0.00 0.17 24.59 0.00 24.59
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   17.33 24.63 0.00 24.63
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 3.67 24.66 0.00 24.66



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: G NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: OFFICE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.17 24.56 0.00 24.56
May 0.00 0.00 0.00 0.00 0.17 24.71 0.00 24.71
June 0.00 0.00 0.00 0.00 3.17 24.88 0.00 24.88
July 0.00 0.00 0.00 0.00 3.33 25.21 0.00 25.21
August 0.00 0.00 0.00 0.00 3.83 25.07 0.00 25.07
September 0.00 0.00 0.00 0.00 3.00 25.08 0.00 25.08
October 0.00 0.00 0.00 0.00 1.17 24.84 0.00 24.84
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   14.83 25.04 0.00 25.04
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 3.83 25.21 0.00 25.21



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: G NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: G N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: G N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: G S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 2.17 24.60 0.00 24.60
February 0.00 0.00 0.00 0.00 0.17 24.56 0.00 24.56
March 0.00 0.00 0.00 0.00 0.17 24.59 0.00 24.59
April 0.00 0.00 0.00 0.00 3.17 24.64 0.00 24.64
May 0.00 0.00 0.00 0.00 3.67 24.66 0.00 24.66
June 0.00 0.00 0.00 0.00 3.67 24.75 0.00 24.75
July 0.00 0.00 0.00 0.00 3.33 24.72 0.00 24.72
August 0.00 0.00 0.00 0.00 3.83 24.72 0.00 24.72
September 0.00 0.00 0.00 0.00 3.33 24.74 0.00 24.74
October 0.00 0.00 0.00 0.00 3.00 24.68 0.00 24.68
November 0.00 0.00 0.00 0.00 2.50 24.60 0.00 24.60
December 0.00 0.00 0.00 0.00 0.83 24.59 0.00 24.59
                 
Annual Sum or Average 0.00   0.00   29.83 24.68 0.00 24.68
Minimum of Months 0.00 0.00 0.00 0.00 0.17 24.56 0.00 24.56
Maximum of Months 0.00 0.00 0.00 0.00 3.83 24.75 0.00 24.75



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: G S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 1.83 24.58 0.00 24.58
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.17 24.57 0.00 24.57
April 0.00 0.00 0.00 0.00 2.83 24.64 0.00 24.64
May 0.00 0.00 0.00 0.00 3.67 24.65 0.00 24.65
June 0.00 0.00 0.00 0.00 3.67 24.73 0.00 24.73
July 0.00 0.00 0.00 0.00 3.33 24.70 0.00 24.70
August 0.00 0.00 0.00 0.00 3.83 24.70 0.00 24.70
September 0.00 0.00 0.00 0.00 3.33 24.72 0.00 24.72
October 0.00 0.00 0.00 0.00 2.83 24.68 0.00 24.68
November 0.00 0.00 0.00 0.00 1.67 24.60 0.00 24.60
December 0.00 0.00 0.00 0.00 0.50 24.57 0.00 24.57
                 
Annual Sum or Average 0.00   0.00   27.67 24.68 0.00 24.68
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 3.83 24.73 0.00 24.73



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: M SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 1.17 24.58 0.00 24.58
May 0.00 0.00 0.00 0.00 1.83 24.60 0.00 24.60
June 0.00 0.00 0.00 0.00 3.50 24.66 0.00 24.66
July 0.00 0.00 0.00 0.00 1.33 24.60 0.00 24.60
August 0.00 0.00 0.00 0.00 1.67 24.64 0.00 24.64
September 0.00 0.00 0.00 0.00 1.33 24.63 0.00 24.63
October 0.00 0.00 0.00 0.00 1.17 24.59 0.00 24.59
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   12.00 24.62 0.00 24.62
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 3.50 24.66 0.00 24.66



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: M NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: M SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 1.67 24.59 0.00 24.59
May 0.00 0.00 0.00 0.00 2.17 24.60 0.00 24.60
June 0.00 0.00 0.00 0.00 3.50 24.67 0.00 24.67
July 0.00 0.00 0.00 0.00 2.67 24.61 0.00 24.61
August 0.00 0.00 0.00 0.00 2.50 24.63 0.00 24.63
September 0.00 0.00 0.00 0.00 2.17 24.63 0.00 24.63
October 0.00 0.00 0.00 0.00 1.50 24.60 0.00 24.60
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   16.17 24.62 0.00 24.62
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 3.50 24.67 0.00 24.67



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: M NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: M N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: M N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: M S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 2.00 24.60 0.00 24.60
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.17 24.56 0.00 24.56
April 0.00 0.00 0.00 0.00 2.33 24.61 0.00 24.61
May 0.00 0.00 0.00 0.00 3.33 24.61 0.00 24.61
June 0.00 0.00 0.00 0.00 3.67 24.67 0.00 24.67
July 0.00 0.00 0.00 0.00 3.00 24.64 0.00 24.64
August 0.00 0.00 0.00 0.00 3.67 24.64 0.00 24.64
September 0.00 0.00 0.00 0.00 3.00 24.67 0.00 24.67
October 0.00 0.00 0.00 0.00 2.33 24.66 0.00 24.66
November 0.00 0.00 0.00 0.00 1.17 24.60 0.00 24.60
December 0.00 0.00 0.00 0.00 0.33 24.58 0.00 24.58
                 
Annual Sum or Average 0.00   0.00   25.00 24.64 0.00 24.64
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 3.67 24.67 0.00 24.67



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: M S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 2.00 24.60 0.00 24.60
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.17 24.56 0.00 24.56
April 0.00 0.00 0.00 0.00 2.33 24.61 0.00 24.61
May 0.00 0.00 0.00 0.00 3.50 24.61 0.00 24.61
June 0.00 0.00 0.00 0.00 3.67 24.67 0.00 24.67
July 0.00 0.00 0.00 0.00 3.00 24.64 0.00 24.64
August 0.00 0.00 0.00 0.00 3.67 24.64 0.00 24.64
September 0.00 0.00 0.00 0.00 3.00 24.67 0.00 24.67
October 0.00 0.00 0.00 0.00 2.33 24.66 0.00 24.66
November 0.00 0.00 0.00 0.00 1.17 24.60 0.00 24.60
December 0.00 0.00 0.00 0.00 0.50 24.57 0.00 24.57
                 
Annual Sum or Average 0.00   0.00   25.33 24.64 0.00 24.64
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 3.67 24.67 0.00 24.67



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: T SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 1.67 24.64 0.00 24.64
May 0.00 0.00 0.00 0.00 2.50 24.65 0.00 24.65
June 0.00 0.00 0.00 0.00 3.67 24.81 0.00 24.81
July 0.00 0.00 0.00 0.00 2.00 24.66 0.00 24.66
August 0.00 0.00 0.00 0.00 2.50 24.72 0.00 24.72
September 0.00 0.00 0.00 0.00 2.17 24.67 0.00 24.67
October 0.00 0.00 0.00 0.00 1.33 24.64 0.00 24.64
November 0.00 0.00 0.00 0.00 0.17 24.56 0.00 24.56
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   16.00 24.70 0.00 24.70
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 3.67 24.81 0.00 24.81



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: T NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: T SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 1.83 24.66 0.00 24.66
May 0.00 0.00 0.00 0.00 3.00 24.66 0.00 24.66
June 0.00 0.00 0.00 0.00 3.67 24.83 0.00 24.83
July 0.00 0.00 0.00 0.00 3.00 24.70 0.00 24.70
August 0.00 0.00 0.00 0.00 2.83 24.74 0.00 24.74
September 0.00 0.00 0.00 0.00 2.83 24.69 0.00 24.69
October 0.00 0.00 0.00 0.00 1.50 24.66 0.00 24.66
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   18.67 24.72 0.00 24.72
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 3.67 24.83 0.00 24.83



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: T NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: T N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: T N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: T S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.33 24.58 0.00 24.58
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.17 24.57 0.00 24.57
April 0.00 0.00 0.00 0.00 2.17 24.66 0.00 24.66
May 0.00 0.00 0.00 0.00 3.17 24.66 0.00 24.66
June 0.00 0.00 0.00 0.00 3.67 24.81 0.00 24.81
July 0.00 0.00 0.00 0.00 3.00 24.70 0.00 24.70
August 0.00 0.00 0.00 0.00 3.67 24.70 0.00 24.70
September 0.00 0.00 0.00 0.00 3.17 24.71 0.00 24.71
October 0.00 0.00 0.00 0.00 2.00 24.68 0.00 24.68
November 0.00 0.00 0.00 0.00 0.50 24.60 0.00 24.60
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   21.83 24.70 0.00 24.70
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 3.67 24.81 0.00 24.81



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: T S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.33 24.58 0.00 24.58
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.17 24.58 0.00 24.58
April 0.00 0.00 0.00 0.00 2.17 24.67 0.00 24.67
May 0.00 0.00 0.00 0.00 3.33 24.66 0.00 24.66
June 0.00 0.00 0.00 0.00 3.67 24.81 0.00 24.81
July 0.00 0.00 0.00 0.00 3.00 24.71 0.00 24.71
August 0.00 0.00 0.00 0.00 3.67 24.71 0.00 24.71
September 0.00 0.00 0.00 0.00 3.17 24.71 0.00 24.71
October 0.00 0.00 0.00 0.00 2.00 24.68 0.00 24.68
November 0.00 0.00 0.00 0.00 0.50 24.60 0.00 24.60
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   22.00 24.71 0.00 24.71
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 3.67 24.81 0.00 24.81



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: T CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: G CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: M CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: ComfortReportSimple55Monthly

For: G SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 201.17 23.86 100.33 24.39 0.00 24.39
February 396.83 23.50 9.00 23.53 0.00 23.53
March 353.33 23.53 24.00 23.64 0.00 23.64
April 160.00 23.99 38.67 24.27 0.00 24.27
May 132.50 24.03 8.33 24.12 0.00 24.12
June 0.00 0.00 129.17 24.38 0.00 24.38
July 6.00 24.52 424.17 24.07 1.83 24.08
August 3.83 25.74 455.17 24.18 3.83 24.19
September 12.33 25.66 493.83 24.27 12.33 24.30
October 24.50 24.00 268.17 24.70 0.00 24.70
November 137.00 24.40 214.33 24.79 33.83 24.86
December 344.17 23.90 53.67 24.16 0.00 24.16
             
Annual Sum or Average 1771.67 23.81 2218.83 24.18 51.83 24.20
Minimum of Months 0.00 0.00 8.33 23.53 0.00 23.53
Maximum of Months 396.83 25.74 493.83 24.79 33.83 24.86



Table of Contents

Report: ComfortReportSimple55Monthly

For: G NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 680.17 23.46 8.67 23.46 2.67 23.45
February 672.00 22.61 0.00 22.61 0.00 22.61
March 690.33 23.01 0.00 23.01 0.00 23.01
April 414.83 23.99 26.50 24.09 0.00 24.09
May 358.50 24.02 8.50 24.05 0.00 24.05
June 7.83 24.00 114.00 24.44 0.00 24.44
July 10.83 24.61 576.33 24.06 4.33 24.07
August 9.50 25.64 653.67 24.15 9.50 24.17
September 15.50 25.56 606.50 24.28 15.50 24.32
October 152.67 24.04 293.83 24.63 1.33 24.63
November 342.83 24.08 203.33 24.45 35.50 24.50
December 681.50 23.32 3.17 23.33 0.00 23.33
             
Annual Sum or Average 4036.50 23.41 2494.50 23.77 68.83 23.79
Minimum of Months 7.83 22.61 0.00 22.61 0.00 22.61
Maximum of Months 690.33 25.64 653.67 24.63 35.50 24.63



Table of Contents

Report: ComfortReportSimple55Monthly

For: OFFICE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 29.17 23.97 13.83 23.98 0.00 23.98
February 61.33 23.83 0.00 23.83 0.00 23.83
March 84.00 23.80 6.00 23.81 0.00 23.81
April 2.50 24.00 54.50 24.00 0.00 24.00
May 0.00 0.00 41.17 24.00 0.00 24.00
June 0.00 0.00 141.83 24.00 0.00 24.00
July 0.00 0.00 140.00 24.00 0.00 24.00
August 0.00 0.00 160.67 24.00 0.00 24.00
September 0.00 0.00 140.00 24.00 0.00 24.00
October 4.00 24.00 106.17 24.00 0.00 24.00
November 7.17 24.00 65.50 24.00 0.00 24.00
December 68.33 23.91 7.00 23.92 0.00 23.92
             
Annual Sum or Average 256.50 23.87 876.67 23.97 0.00 23.97
Minimum of Months 0.00 0.00 0.00 23.81 0.00 23.81
Maximum of Months 84.00 24.00 160.67 24.00 0.00 24.00



Table of Contents

Report: ComfortReportSimple55Monthly

For: G NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 688.50 23.49 3.33 23.48 1.50 23.48
February 672.00 22.72 0.00 22.72 0.00 22.72
March 680.33 23.10 1.67 23.10 0.00 23.10
April 399.83 23.98 40.33 24.14 0.00 24.14
May 314.83 24.01 34.33 24.20 0.00 24.20
June 10.00 24.00 126.67 24.46 0.00 24.46
July 11.83 24.56 579.67 24.07 4.00 24.08
August 8.83 25.77 651.67 24.15 8.83 24.18
September 14.83 25.67 605.33 24.30 14.83 24.33
October 142.83 24.03 309.00 24.68 1.17 24.69
November 337.17 24.06 186.33 24.37 35.83 24.42
December 681.00 23.37 0.00 23.37 0.00 23.37
             
Annual Sum or Average 3962.00 23.45 2538.33 23.81 66.17 23.83
Minimum of Months 8.83 22.72 0.00 22.72 0.00 22.72
Maximum of Months 688.50 25.77 651.67 24.68 35.83 24.69



Table of Contents

Report: ComfortReportSimple55Monthly

For: G N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 637.00 23.68 7.00 23.69 0.00 23.69
February 672.00 23.26 0.00 23.26 0.00 23.26
March 672.00 23.47 0.67 23.47 0.00 23.47
April 461.00 24.00 16.83 24.06 0.00 24.06
May 504.17 24.01 11.50 24.04 0.00 24.04
June 19.50 24.00 78.50 24.53 0.00 24.53
July 19.83 24.34 568.67 24.06 4.83 24.07
August 9.67 25.63 629.67 24.15 9.67 24.17
September 16.33 25.48 557.00 24.30 16.33 24.33
October 196.50 24.04 257.33 24.51 1.50 24.52
November 335.67 24.15 173.33 24.40 34.83 24.46
December 679.33 23.70 0.00 23.70 0.00 23.70
             
Annual Sum or Average 4223.00 23.73 2300.50 23.94 67.17 23.95
Minimum of Months 9.67 23.26 0.00 23.26 0.00 23.26
Maximum of Months 679.33 25.63 629.67 24.53 34.83 24.53



Table of Contents

Report: ComfortReportSimple55Monthly

For: G N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 637.17 23.68 6.83 23.68 0.00 23.68
February 672.00 23.28 0.00 23.28 0.00 23.28
March 670.67 23.48 0.67 23.48 0.00 23.48
April 459.00 24.00 17.33 24.06 0.00 24.06
May 502.83 24.01 12.17 24.05 0.00 24.05
June 19.33 24.00 78.67 24.53 0.00 24.53
July 19.67 24.34 568.83 24.06 4.83 24.07
August 9.67 25.64 629.83 24.15 9.67 24.17
September 16.33 25.48 557.00 24.30 16.33 24.33
October 194.17 24.04 259.00 24.52 1.50 24.53
November 335.67 24.15 172.50 24.39 34.83 24.45
December 677.33 23.70 0.00 23.70 0.00 23.70
             
Annual Sum or Average 4213.83 23.73 2302.83 23.94 67.17 23.95
Minimum of Months 9.67 23.28 0.00 23.28 0.00 23.28
Maximum of Months 677.33 25.64 629.83 24.53 34.83 24.53



Table of Contents

Report: ComfortReportSimple55Monthly

For: G S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 105.83 23.93 116.00 24.74 0.00 24.74
February 158.50 23.85 23.00 23.99 0.00 23.99
March 208.67 23.84 49.83 24.10 0.00 24.10
April 157.17 24.01 34.67 24.29 0.00 24.29
May 148.50 24.01 11.67 24.13 0.00 24.13
June 0.00 0.00 87.33 24.57 0.00 24.57
July 10.17 24.32 408.83 24.07 2.00 24.08
August 3.83 25.77 443.83 24.18 3.83 24.19
September 12.67 25.61 476.83 24.27 12.67 24.31
October 7.17 24.00 267.33 24.75 0.00 24.75
November 83.83 24.69 226.33 24.93 32.67 25.01
December 259.83 24.00 64.50 24.37 0.00 24.37
             
Annual Sum or Average 1156.17 24.02 2210.17 24.35 51.17 24.37
Minimum of Months 0.00 0.00 11.67 23.99 0.00 23.99
Maximum of Months 259.83 25.77 476.83 24.93 32.67 25.01



Table of Contents

Report: ComfortReportSimple55Monthly

For: G S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 105.17 23.91 116.33 24.74 0.00 24.74
February 169.83 23.84 23.00 23.97 0.00 23.97
March 207.67 23.83 52.00 24.10 0.00 24.10
April 125.83 24.01 40.83 24.37 0.00 24.37
May 93.00 24.01 16.67 24.26 0.00 24.26
June 0.00 0.00 104.67 24.55 0.00 24.55
July 1.17 25.53 415.67 24.08 1.00 24.09
August 3.33 25.87 445.83 24.19 3.33 24.20
September 11.33 25.82 492.33 24.28 11.33 24.32
October 6.00 24.00 280.17 24.76 0.00 24.76
November 82.00 24.73 227.67 24.95 32.67 25.03
December 260.17 23.99 65.00 24.36 0.00 24.36
             
Annual Sum or Average 1065.50 24.01 2280.17 24.37 48.33 24.39
Minimum of Months 0.00 0.00 16.67 23.97 0.00 23.97
Maximum of Months 260.17 25.87 492.33 24.95 32.67 25.03



Table of Contents

Report: ComfortReportSimple55Monthly

For: M SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 172.50 23.89 124.00 24.61 0.00 24.61
February 134.83 23.84 59.00 24.22 0.00 24.22
March 131.67 23.84 123.67 24.62 0.00 24.62
April 120.17 24.02 49.50 24.45 0.00 24.45
May 100.50 24.02 14.67 24.22 0.00 24.22
June 1.00 24.00 118.67 24.40 0.00 24.40
July 17.33 24.31 400.50 24.06 3.83 24.07
August 6.50 25.30 439.00 24.14 6.17 24.16
September 16.50 25.18 423.33 24.23 16.50 24.26
October 84.50 24.03 211.83 24.59 0.50 24.59
November 186.50 24.17 191.83 24.59 35.67 24.63
December 372.67 23.83 54.17 24.09 0.00 24.09
             
Annual Sum or Average 1344.67 23.96 2210.17 24.33 62.67 24.34
Minimum of Months 1.00 23.83 14.67 24.06 0.00 24.07
Maximum of Months 372.67 25.30 439.00 24.62 35.67 24.63



Table of Contents

Report: ComfortReportSimple55Monthly

For: M NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 522.33 23.64 37.00 23.75 0.00 23.75
February 454.67 23.59 24.83 23.66 0.00 23.66
March 334.50 23.74 89.67 24.10 0.00 24.10
April 301.83 24.03 48.67 24.28 0.00 24.28
May 242.33 24.02 20.00 24.14 0.00 24.14
June 12.00 24.00 99.50 24.47 0.00 24.47
July 28.17 24.24 560.33 24.05 5.50 24.06
August 22.83 24.67 608.83 24.12 11.67 24.14
September 24.83 25.03 516.17 24.25 24.83 24.28
October 265.17 24.03 205.00 24.34 2.17 24.35
November 425.33 23.88 153.50 24.13 37.67 24.17
December 691.17 23.13 16.17 23.11 13.17 23.07
             
Annual Sum or Average 3325.17 23.69 2379.67 23.96 95.00 23.97
Minimum of Months 12.00 23.13 16.17 23.11 0.00 23.07
Maximum of Months 691.17 25.03 608.83 24.47 37.67 24.47



Table of Contents

Report: ComfortReportSimple55Monthly

For: M SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 175.17 23.89 124.83 24.60 0.00 24.60
February 124.83 23.85 67.50 24.26 0.00 24.26
March 133.17 23.85 119.83 24.61 0.00 24.61
April 113.33 24.01 59.67 24.57 0.00 24.57
May 98.83 24.01 29.50 24.44 0.00 24.44
June 2.33 24.00 116.33 24.48 0.00 24.48
July 16.33 24.33 403.50 24.08 3.50 24.09
August 7.33 25.14 433.67 24.16 5.67 24.17
September 15.83 25.27 422.67 24.24 15.83 24.28
October 84.17 24.02 215.83 24.61 0.33 24.61
November 187.33 24.13 189.33 24.54 37.50 24.56
December 371.33 23.83 60.83 24.12 0.00 24.12
             
Annual Sum or Average 1330.00 23.96 2243.50 24.35 62.83 24.36
Minimum of Months 2.33 23.83 29.50 24.08 0.00 24.09
Maximum of Months 371.33 25.27 433.67 24.61 37.50 24.61



Table of Contents

Report: ComfortReportSimple55Monthly

For: M NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 506.33 23.62 16.83 23.66 0.00 23.66
February 426.17 23.66 30.50 23.73 0.00 23.73
March 317.33 23.80 115.83 24.21 0.00 24.21
April 271.33 24.01 81.50 24.45 0.00 24.45
May 210.67 24.01 52.33 24.40 0.00 24.40
June 14.00 24.00 114.00 24.50 0.00 24.50
July 22.17 24.34 569.17 24.06 5.17 24.07
August 26.00 24.63 609.33 24.14 11.67 24.16
September 23.67 25.18 516.50 24.28 23.67 24.31
October 265.33 24.03 219.83 24.40 2.00 24.40
November 420.83 23.89 148.17 24.10 42.33 24.13
December 684.67 23.18 9.83 23.15 9.83 23.13
             
Annual Sum or Average 3188.50 23.70 2483.83 24.01 94.67 24.02
Minimum of Months 14.00 23.18 9.83 23.15 0.00 23.13
Maximum of Months 684.67 25.18 609.33 24.50 42.33 24.50



Table of Contents

Report: ComfortReportSimple55Monthly

For: M N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 466.33 23.82 21.83 23.87 0.00 23.87
February 329.17 23.91 32.83 23.98 0.00 23.98
March 253.67 23.96 82.00 24.28 0.00 24.28
April 410.33 24.02 28.67 24.12 0.00 24.12
May 473.83 24.01 18.33 24.07 0.00 24.07
June 35.83 24.00 50.00 24.53 0.00 24.53
July 56.83 24.12 528.67 24.04 6.83 24.05
August 36.50 24.40 568.33 24.12 11.50 24.15
September 25.17 25.03 481.83 24.27 25.17 24.30
October 268.33 24.06 182.17 24.29 2.17 24.29
November 394.33 24.07 144.00 24.24 38.50 24.29
December 673.17 23.66 0.00 23.66 0.00 23.66
             
Annual Sum or Average 3423.50 23.93 2138.67 24.08 84.17 24.09
Minimum of Months 25.17 23.66 0.00 23.66 0.00 23.66
Maximum of Months 673.17 25.03 568.33 24.53 38.50 24.53



Table of Contents

Report: ComfortReportSimple55Monthly

For: M N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 466.00 23.82 20.33 23.86 0.00 23.86
February 326.50 23.91 33.67 23.99 0.00 23.99
March 250.67 23.96 84.67 24.30 0.00 24.30
April 408.33 24.02 29.00 24.12 0.00 24.12
May 472.00 24.01 18.83 24.07 0.00 24.07
June 35.83 24.00 50.33 24.53 0.00 24.53
July 57.17 24.12 529.33 24.04 6.33 24.05
August 36.33 24.41 568.50 24.12 11.50 24.15
September 25.17 25.04 482.00 24.27 25.17 24.30
October 267.33 24.05 183.50 24.29 2.17 24.30
November 393.83 24.07 143.83 24.24 38.83 24.28
December 672.33 23.66 0.00 23.66 0.00 23.66
             
Annual Sum or Average 3411.50 23.93 2144.00 24.08 84.00 24.09
Minimum of Months 25.17 23.66 0.00 23.66 0.00 23.66
Maximum of Months 672.33 25.04 568.50 24.53 38.83 24.53



Table of Contents

Report: ComfortReportSimple55Monthly

For: M S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 106.67 23.96 133.83 24.86 0.00 24.86
February 44.67 23.98 83.17 24.54 0.00 24.54
March 103.50 23.97 123.00 24.74 0.00 24.74
April 137.33 24.01 42.50 24.40 0.00 24.40
May 145.00 24.01 14.00 24.15 0.00 24.15
June 5.83 24.00 58.67 24.65 0.00 24.65
July 25.33 24.19 389.17 24.06 3.67 24.07
August 9.50 24.87 414.33 24.15 5.83 24.17
September 16.17 25.19 398.17 24.25 16.17 24.28
October 57.67 24.02 212.83 24.66 0.33 24.66
November 145.67 24.26 203.50 24.68 34.33 24.72
December 313.00 23.98 65.67 24.32 0.00 24.32
             
Annual Sum or Average 1110.33 24.05 2138.83 24.40 60.33 24.42
Minimum of Months 5.83 23.96 14.00 24.06 0.00 24.07
Maximum of Months 313.00 25.19 414.33 24.86 34.33 24.86



Table of Contents

Report: ComfortReportSimple55Monthly

For: M S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 107.00 23.96 133.83 24.86 0.00 24.86
February 43.83 23.98 84.33 24.55 0.00 24.55
March 103.50 23.97 123.67 24.75 0.00 24.75
April 135.17 24.01 42.50 24.40 0.00 24.40
May 143.00 24.01 14.83 24.16 0.00 24.16
June 5.67 24.00 58.83 24.65 0.00 24.65
July 25.00 24.20 389.50 24.06 3.67 24.07
August 9.67 24.86 414.17 24.15 5.83 24.17
September 16.17 25.19 398.50 24.25 16.17 24.28
October 57.33 24.02 213.33 24.66 0.33 24.66
November 146.17 24.26 203.17 24.68 34.50 24.72
December 312.17 23.98 66.00 24.32 0.00 24.32
             
Annual Sum or Average 1104.67 24.05 2142.67 24.41 60.50 24.42
Minimum of Months 5.67 23.96 14.83 24.06 0.00 24.07
Maximum of Months 312.17 25.19 414.17 24.86 34.50 24.86



Table of Contents

Report: ComfortReportSimple55Monthly

For: T SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 356.83 22.82 107.17 23.35 14.33 23.30
February 389.17 22.42 36.00 22.65 1.67 22.64
March 330.50 22.83 122.67 23.30 25.67 23.20
April 233.17 23.84 74.17 24.08 0.67 24.09
May 221.50 23.96 40.67 23.99 0.00 23.99
June 35.67 24.04 180.17 24.09 0.00 24.09
July 39.17 24.24 418.50 24.04 11.00 24.06
August 27.83 24.47 434.33 24.12 11.17 24.14
September 29.33 24.70 399.00 24.17 28.67 24.21
October 221.67 23.49 181.50 24.06 2.17 24.07
November 346.50 23.09 153.67 23.55 72.00 23.57
December 450.50 22.40 147.17 22.42 104.17 22.22
             
Annual Sum or Average 2681.83 23.04 2295.00 23.57 271.50 23.52
Minimum of Months 27.83 22.40 36.00 22.42 0.00 22.22
Maximum of Months 450.50 24.70 434.33 24.17 104.17 24.21



Table of Contents

Report: ComfortReportSimple55Monthly

For: T NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 666.00 22.52 75.33 22.49 55.50 22.39
February 644.33 22.09 40.00 22.07 34.00 22.03
March 549.00 22.62 111.50 22.79 50.33 22.67
April 327.67 23.81 74.50 24.09 0.33 24.09
May 263.67 23.98 40.83 24.04 0.00 24.04
June 51.67 24.02 284.67 24.10 0.00 24.10
July 48.00 24.23 599.83 24.04 18.17 24.05
August 40.17 24.58 643.17 24.11 17.83 24.14
September 46.17 24.63 555.83 24.19 39.17 24.23
October 376.50 23.21 209.17 23.67 12.67 23.64
November 587.67 22.71 206.83 22.87 139.00 22.80
December 726.33 21.90 317.33 21.67 315.67 21.54
             
Annual Sum or Average 4327.17 22.72 3159.00 23.14 682.67 23.02
Minimum of Months 40.17 21.90 40.00 21.67 0.00 21.54
Maximum of Months 726.33 24.63 643.17 24.19 315.67 24.23



Table of Contents

Report: ComfortReportSimple55Monthly

For: T SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 355.67 22.82 109.50 23.35 13.33 23.30
February 382.67 22.43 42.00 22.70 1.33 22.70
March 327.50 22.83 121.50 23.30 22.67 23.20
April 232.00 23.88 69.00 24.17 1.17 24.19
May 214.50 23.97 31.33 24.10 0.00 24.10
June 42.33 24.02 181.50 24.16 0.00 24.16
July 36.33 24.27 415.83 24.06 10.00 24.08
August 28.33 24.55 434.67 24.13 11.17 24.16
September 28.33 24.78 399.50 24.19 28.00 24.23
October 218.50 23.49 175.83 24.07 1.83 24.08
November 350.33 23.07 152.00 23.50 71.00 23.50
December 447.67 22.41 150.67 22.44 105.00 22.24
             
Annual Sum or Average 2664.17 23.05 2283.33 23.59 265.50 23.53
Minimum of Months 28.33 22.41 31.33 22.44 0.00 22.24
Maximum of Months 447.67 24.78 434.67 24.19 105.00 24.23



Table of Contents

Report: ComfortReportSimple55Monthly

For: T NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 702.50 22.67 57.50 22.60 47.50 22.51
February 642.33 22.19 39.50 22.16 34.50 22.11
March 540.17 22.74 108.00 22.92 41.50 22.81
April 284.33 23.83 103.17 24.32 0.83 24.32
May 245.83 23.97 60.67 24.26 0.17 24.27
June 58.17 24.01 338.33 24.13 0.00 24.13
July 45.67 24.28 606.83 24.05 17.50 24.07
August 40.50 24.67 644.33 24.13 18.00 24.17
September 45.17 24.74 555.67 24.23 37.67 24.27
October 361.67 23.33 218.67 23.83 9.67 23.80
November 602.17 22.77 189.83 22.85 135.50 22.79
December 740.17 21.95 298.33 21.71 298.33 21.58
             
Annual Sum or Average 4308.67 22.78 3220.83 23.22 641.17 23.11
Minimum of Months 40.50 21.95 39.50 21.71 0.00 21.58
Maximum of Months 740.17 24.74 644.33 24.32 298.33 24.32



Table of Contents

Report: ComfortReportSimple55Monthly

For: T N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 709.33 22.85 42.83 22.80 33.17 22.73
February 648.67 22.38 9.17 22.37 7.33 22.35
March 561.50 22.95 66.50 23.03 27.50 22.95
April 365.33 23.94 41.00 24.13 0.00 24.13
May 286.50 24.01 14.33 24.10 0.00 24.10
June 58.83 24.01 142.00 24.18 0.00 24.18
July 48.50 24.23 558.67 24.05 15.33 24.06
August 40.83 24.53 617.83 24.12 15.50 24.15
September 38.83 24.79 517.50 24.22 36.17 24.26
October 392.50 23.52 174.00 23.84 3.17 23.84
November 595.83 22.94 143.50 23.13 83.83 23.14
December 743.50 22.06 239.00 21.83 239.00 21.69
             
Annual Sum or Average 4490.17 22.96 2566.33 23.28 461.00 23.20
Minimum of Months 38.83 22.06 9.17 21.83 0.00 21.69
Maximum of Months 743.50 24.79 617.83 24.22 239.00 24.26



Table of Contents

Report: ComfortReportSimple55Monthly

For: T N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 708.83 22.85 42.83 22.79 33.50 22.72
February 647.50 22.39 10.00 22.38 7.50 22.37
March 557.33 22.95 68.33 23.04 27.67 22.96
April 359.00 23.93 43.17 24.13 0.00 24.13
May 284.00 24.01 16.33 24.11 0.00 24.11
June 60.00 24.01 142.83 24.18 0.00 24.18
July 48.17 24.24 558.50 24.05 15.33 24.06
August 40.33 24.54 618.00 24.12 15.50 24.15
September 38.83 24.79 518.00 24.22 36.17 24.26
October 390.50 23.53 178.67 23.87 3.17 23.88
November 603.17 22.95 142.00 23.12 90.17 23.14
December 744.00 22.06 240.00 21.83 240.00 21.70
             
Annual Sum or Average 4481.67 22.96 2578.67 23.28 469.00 23.21
Minimum of Months 38.83 22.06 10.00 21.83 0.00 21.70
Maximum of Months 744.00 24.79 618.00 24.22 240.00 24.26



Table of Contents

Report: ComfortReportSimple55Monthly

For: T S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 332.83 23.28 107.67 23.82 3.50 23.81
February 351.83 22.90 40.50 23.15 0.00 23.15
March 302.33 23.18 106.00 23.65 8.33 23.60
April 233.00 23.95 44.50 24.16 0.00 24.16
May 232.83 24.01 5.83 24.04 0.00 24.04
June 40.33 24.03 110.50 24.14 0.00 24.14
July 38.50 24.24 396.00 24.05 8.83 24.07
August 25.67 24.45 422.17 24.12 9.17 24.14
September 25.83 24.81 390.17 24.19 25.83 24.23
October 198.33 23.74 176.83 24.23 1.00 24.24
November 318.33 23.46 155.17 23.90 61.00 23.91
December 434.00 22.81 96.17 22.92 49.33 22.77
             
Annual Sum or Average 2533.83 23.38 2051.50 23.81 167.00 23.79
Minimum of Months 25.67 22.81 5.83 22.92 0.00 22.77
Maximum of Months 434.00 24.81 422.17 24.23 61.00 24.24



Table of Contents

Report: ComfortReportSimple55Monthly

For: T S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 332.67 23.28 107.50 23.82 3.50 23.80
February 350.33 22.90 41.33 23.15 0.00 23.15
March 301.67 23.18 107.33 23.66 8.33 23.61
April 232.33 23.96 45.00 24.17 0.17 24.17
May 232.33 24.00 6.50 24.04 0.00 24.04
June 41.17 24.03 110.17 24.14 0.00 24.14
July 38.17 24.25 395.50 24.05 8.67 24.07
August 25.83 24.44 421.83 24.12 9.17 24.14
September 25.67 24.82 389.83 24.19 25.67 24.23
October 198.00 23.74 177.00 24.24 1.00 24.24
November 318.83 23.46 154.83 23.89 61.33 23.90
December 433.83 22.81 96.33 22.93 48.83 22.77
             
Annual Sum or Average 2530.83 23.38 2053.17 23.81 166.67 23.79
Minimum of Months 25.67 22.81 6.50 22.93 0.00 22.77
Maximum of Months 433.83 24.82 421.83 24.24 61.33 24.24



Table of Contents

Report: ComfortReportSimple55Monthly

For: T CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 24.03 744.00 24.03 744.00 24.03
February 672.00 23.32 672.00 23.32 672.00 23.32
March 744.00 24.23 744.00 24.23 744.00 24.23
April 720.00 25.87 720.00 25.87 720.00 25.87
May 744.00 26.16 744.00 26.16 744.00 26.16
June 720.00 26.79 720.00 26.79 720.00 26.79
July 744.00 26.70 744.00 26.70 744.00 26.70
August 744.00 26.65 744.00 26.65 744.00 26.65
September 720.00 26.44 720.00 26.44 720.00 26.44
October 744.00 25.40 744.00 25.40 744.00 25.40
November 720.00 24.34 720.00 24.34 720.00 24.34
December 744.00 22.92 744.00 22.92 744.00 22.92
             
Annual Sum or Average 8760.00 25.25 8760.00 25.25 8760.00 25.25
Minimum of Months 672.00 22.92 672.00 22.92 672.00 22.92
Maximum of Months 744.00 26.79 744.00 26.79 744.00 26.79



Table of Contents

Report: ComfortReportSimple55Monthly

For: G CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 236.00 22.89 295.17 24.36 34.33 24.30
February 521.17 22.96 143.33 23.22 80.50 23.24
March 388.17 23.19 271.17 24.07 36.33 23.99
April 62.50 25.07 640.67 26.91 28.50 26.96
May 71.17 28.20 715.00 27.64 61.83 27.74
June 605.33 28.74 719.50 28.63 605.33 28.67
July 719.00 28.49 743.17 28.47 719.00 28.48
August 722.50 28.44 744.00 28.41 722.50 28.42
September 684.67 28.21 720.00 28.16 684.67 28.18
October 238.83 27.14 655.17 27.13 205.17 27.30
November 218.83 24.34 493.83 25.51 114.83 25.56
December 395.00 22.90 188.83 23.56 21.17 23.34
             
Annual Sum or Average 4863.17 26.43 6329.83 26.97 3314.17 27.21
Minimum of Months 62.50 22.89 143.33 23.22 21.17 23.24
Maximum of Months 722.50 28.74 744.00 28.63 722.50 28.67



Table of Contents

Report: ComfortReportSimple55Monthly

For: M CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 744.00 25.61 744.00 25.61 744.00 25.61
February 672.00 25.28 672.00 25.28 672.00 25.28
March 744.00 25.64 744.00 25.64 744.00 25.64
April 720.00 26.18 720.00 26.18 720.00 26.18
May 744.00 26.26 744.00 26.26 744.00 26.26
June 720.00 26.51 720.00 26.51 720.00 26.51
July 744.00 26.37 744.00 26.37 744.00 26.37
August 744.00 26.39 744.00 26.39 744.00 26.39
September 720.00 26.32 720.00 26.32 720.00 26.32
October 744.00 26.09 744.00 26.09 744.00 26.09
November 720.00 25.77 720.00 25.77 720.00 25.77
December 744.00 25.10 744.00 25.10 744.00 25.10
             
Annual Sum or Average 8760.00 25.96 8760.00 25.96 8760.00 25.96
Minimum of Months 672.00 25.10 672.00 25.10 672.00 25.10
Maximum of Months 744.00 26.51 744.00 26.51 744.00 26.51



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_GSW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 533.00000 0.00000 0.00000 0.00000 0.00000
February 473.00000 0.00000 0.00000 0.00000 0.00000
March 506.00000 0.00000 0.00000 0.00000 0.00000
April 510.00000 0.00000 0.00000 0.00000 0.00000
May 515.00000 0.00000 0.00000 0.00000 0.00000
June 492.00000 0.00000 0.00000 0.00000 0.00000
July 533.00000 0.00000 0.00000 0.00000 0.00000
August 506.00000 0.00000 0.00000 0.00000 0.00000
September 510.00000 0.00000 0.00000 0.00000 0.00000
October 524.00000 0.00000 0.00000 0.00000 0.00000
November 510.00000 0.00000 0.00000 0.00000 0.00000
December 533.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 6145.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 473.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 533.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_GNW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 744.00000 0.00000 0.00000 0.00000 0.00000
February 672.00000 0.00000 0.00000 0.00000 0.00000
March 744.00000 0.00000 0.00000 0.00000 0.00000
April 720.00000 0.00000 0.00000 0.00000 0.00000
May 744.00000 0.00000 0.00000 0.00000 0.00000
June 720.00000 0.00000 0.00000 0.00000 0.00000
July 744.00000 0.00000 0.00000 0.00000 0.00000
August 744.00000 0.00000 0.00000 0.00000 0.00000
September 720.00000 0.00000 0.00000 0.00000 0.00000
October 744.00000 0.00000 0.00000 0.00000 0.00000
November 720.00000 0.00000 0.00000 0.00000 0.00000
December 744.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 8760.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 672.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 744.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_OFFICE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 140.00000 0.00000 0.00000 0.00000 0.00000
February 133.00000 0.00000 0.00000 0.00000 0.00000
March 161.00000 0.00000 0.00000 0.00000 0.00000
April 140.00000 0.00000 0.00000 0.00000 0.00000
May 154.00000 0.00000 0.00000 0.00000 0.00000
June 154.00000 0.00000 0.00000 0.00000 0.00000
July 140.00000 0.00000 0.00000 0.00000 0.00000
August 161.00000 0.00000 0.00000 0.00000 0.00000
September 140.00000 0.00000 0.00000 0.00000 0.00000
October 147.00000 0.00000 0.00000 0.00000 0.00000
November 140.00000 0.00000 0.00000 0.00000 0.00000
December 140.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 1750.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 133.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 161.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_GNE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 744.00000 0.00000 0.00000 0.00000 0.00000
February 672.00000 0.00000 0.00000 0.00000 0.00000
March 744.00000 0.00000 0.00000 0.00000 0.00000
April 720.00000 0.00000 0.00000 0.00000 0.00000
May 744.00000 0.00000 0.00000 0.00000 0.00000
June 720.00000 0.00000 0.00000 0.00000 0.00000
July 744.00000 0.00000 0.00000 0.00000 0.00000
August 744.00000 0.00000 0.00000 0.00000 0.00000
September 720.00000 0.00000 0.00000 0.00000 0.00000
October 744.00000 0.00000 0.00000 0.00000 0.00000
November 720.00000 0.00000 0.00000 0.00000 0.00000
December 744.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 8760.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 672.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 744.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_GN1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 744.00000 0.00000 0.00000 0.00000 0.00000
February 672.00000 0.00000 0.00000 0.00000 0.00000
March 744.00000 0.00000 0.00000 0.00000 0.00000
April 720.00000 0.00000 0.00000 0.00000 0.00000
May 744.00000 0.00000 0.00000 0.00000 0.00000
June 720.00000 0.00000 0.00000 0.00000 0.00000
July 744.00000 0.00000 0.00000 0.00000 0.00000
August 744.00000 0.00000 0.00000 0.00000 0.00000
September 720.00000 0.00000 0.00000 0.00000 0.00000
October 744.00000 0.00000 0.00000 0.00000 0.00000
November 720.00000 0.00000 0.00000 0.00000 0.00000
December 744.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 8760.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 672.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 744.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_GN2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 744.00000 0.00000 0.00000 0.00000 0.00000
February 672.00000 0.00000 0.00000 0.00000 0.00000
March 744.00000 0.00000 0.00000 0.00000 0.00000
April 720.00000 0.00000 0.00000 0.00000 0.00000
May 744.00000 0.00000 0.00000 0.00000 0.00000
June 720.00000 0.00000 0.00000 0.00000 0.00000
July 744.00000 0.00000 0.00000 0.00000 0.00000
August 744.00000 0.00000 0.00000 0.00000 0.00000
September 720.00000 0.00000 0.00000 0.00000 0.00000
October 744.00000 0.00000 0.00000 0.00000 0.00000
November 720.00000 0.00000 0.00000 0.00000 0.00000
December 744.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 8760.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 672.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 744.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_GS1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 533.00000 0.00000 0.00000 0.00000 0.00000
February 473.00000 0.00000 0.00000 0.00000 0.00000
March 506.00000 0.00000 0.00000 0.00000 0.00000
April 510.00000 0.00000 0.00000 0.00000 0.00000
May 515.00000 0.00000 0.00000 0.00000 0.00000
June 492.00000 0.00000 0.00000 0.00000 0.00000
July 533.00000 0.00000 0.00000 0.00000 0.00000
August 506.00000 0.00000 0.00000 0.00000 0.00000
September 510.00000 0.00000 0.00000 0.00000 0.00000
October 524.00000 0.00000 0.00000 0.00000 0.00000
November 510.00000 0.00000 0.00000 0.00000 0.00000
December 533.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 6145.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 473.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 533.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_GS2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 533.00000 0.00000 0.00000 0.00000 0.00000
February 473.00000 0.00000 0.00000 0.00000 0.00000
March 506.00000 0.00000 0.00000 0.00000 0.00000
April 510.00000 0.00000 0.00000 0.00000 0.00000
May 515.00000 0.00000 0.00000 0.00000 0.00000
June 492.00000 0.00000 0.00000 0.00000 0.00000
July 533.00000 0.00000 0.00000 0.00000 0.00000
August 506.00000 0.00000 0.00000 0.00000 0.00000
September 510.00000 0.00000 0.00000 0.00000 0.00000
October 524.00000 0.00000 0.00000 0.00000 0.00000
November 510.00000 0.00000 0.00000 0.00000 0.00000
December 533.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 6145.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 473.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 533.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_MSW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 533.00000 0.00000 0.00000 0.00000 0.00000
February 473.00000 0.00000 0.00000 0.00000 0.00000
March 506.00000 0.00000 0.00000 0.00000 0.00000
April 510.00000 0.00000 0.00000 0.00000 0.00000
May 515.00000 0.00000 0.00000 0.00000 0.00000
June 492.00000 0.00000 0.00000 0.00000 0.00000
July 533.00000 0.00000 0.00000 0.00000 0.00000
August 506.00000 0.00000 0.00000 0.00000 0.00000
September 510.00000 0.00000 0.00000 0.00000 0.00000
October 524.00000 0.00000 0.00000 0.00000 0.00000
November 510.00000 0.00000 0.00000 0.00000 0.00000
December 533.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 6145.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 473.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 533.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_MNW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 744.00000 0.00000 0.00000 0.00000 0.00000
February 672.00000 0.00000 0.00000 0.00000 0.00000
March 744.00000 0.00000 0.00000 0.00000 0.00000
April 720.00000 0.00000 0.00000 0.00000 0.00000
May 744.00000 0.00000 0.00000 0.00000 0.00000
June 720.00000 0.00000 0.00000 0.00000 0.00000
July 744.00000 0.00000 0.00000 0.00000 0.00000
August 744.00000 0.00000 0.00000 0.00000 0.00000
September 720.00000 0.00000 0.00000 0.00000 0.00000
October 744.00000 0.00000 0.00000 0.00000 0.00000
November 720.00000 0.00000 0.00000 0.00000 0.00000
December 744.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 8760.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 672.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 744.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_MSE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 533.00000 0.00000 0.00000 0.00000 0.00000
February 473.00000 0.00000 0.00000 0.00000 0.00000
March 506.00000 0.00000 0.00000 0.00000 0.00000
April 510.00000 0.00000 0.00000 0.00000 0.00000
May 515.00000 0.00000 0.00000 0.00000 0.00000
June 492.00000 0.00000 0.00000 0.00000 0.00000
July 533.00000 0.00000 0.00000 0.00000 0.00000
August 506.00000 0.00000 0.00000 0.00000 0.00000
September 510.00000 0.00000 0.00000 0.00000 0.00000
October 524.00000 0.00000 0.00000 0.00000 0.00000
November 510.00000 0.00000 0.00000 0.00000 0.00000
December 533.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 6145.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 473.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 533.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_MNE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 744.00000 0.00000 0.00000 0.00000 0.00000
February 672.00000 0.00000 0.00000 0.00000 0.00000
March 744.00000 0.00000 0.00000 0.00000 0.00000
April 720.00000 0.00000 0.00000 0.00000 0.00000
May 744.00000 0.00000 0.00000 0.00000 0.00000
June 720.00000 0.00000 0.00000 0.00000 0.00000
July 744.00000 0.00000 0.00000 0.00000 0.00000
August 744.00000 0.00000 0.00000 0.00000 0.00000
September 720.00000 0.00000 0.00000 0.00000 0.00000
October 744.00000 0.00000 0.00000 0.00000 0.00000
November 720.00000 0.00000 0.00000 0.00000 0.00000
December 744.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 8760.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 672.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 744.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_MN1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 744.00000 0.00000 0.00000 0.00000 0.00000
February 672.00000 0.00000 0.00000 0.00000 0.00000
March 744.00000 0.00000 0.00000 0.00000 0.00000
April 720.00000 0.00000 0.00000 0.00000 0.00000
May 744.00000 0.00000 0.00000 0.00000 0.00000
June 720.00000 0.00000 0.00000 0.00000 0.00000
July 744.00000 0.00000 0.00000 0.00000 0.00000
August 744.00000 0.00000 0.00000 0.00000 0.00000
September 720.00000 0.00000 0.00000 0.00000 0.00000
October 744.00000 0.00000 0.00000 0.00000 0.00000
November 720.00000 0.00000 0.00000 0.00000 0.00000
December 744.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 8760.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 672.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 744.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_MN2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 744.00000 0.00000 0.00000 0.00000 0.00000
February 672.00000 0.00000 0.00000 0.00000 0.00000
March 744.00000 0.00000 0.00000 0.00000 0.00000
April 720.00000 0.00000 0.00000 0.00000 0.00000
May 744.00000 0.00000 0.00000 0.00000 0.00000
June 720.00000 0.00000 0.00000 0.00000 0.00000
July 744.00000 0.00000 0.00000 0.00000 0.00000
August 744.00000 0.00000 0.00000 0.00000 0.00000
September 720.00000 0.00000 0.00000 0.00000 0.00000
October 744.00000 0.00000 0.00000 0.00000 0.00000
November 720.00000 0.00000 0.00000 0.00000 0.00000
December 744.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 8760.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 672.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 744.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_MS1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 533.00000 0.00000 0.00000 0.00000 0.00000
February 473.00000 0.00000 0.00000 0.00000 0.00000
March 506.00000 0.00000 0.00000 0.00000 0.00000
April 510.00000 0.00000 0.00000 0.00000 0.00000
May 515.00000 0.00000 0.00000 0.00000 0.00000
June 492.00000 0.00000 0.00000 0.00000 0.00000
July 533.00000 0.00000 0.00000 0.00000 0.00000
August 506.00000 0.00000 0.00000 0.00000 0.00000
September 510.00000 0.00000 0.00000 0.00000 0.00000
October 524.00000 0.00000 0.00000 0.00000 0.00000
November 510.00000 0.00000 0.00000 0.00000 0.00000
December 533.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 6145.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 473.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 533.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_MS2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 533.00000 0.00000 0.00000 0.00000 0.00000
February 473.00000 0.00000 0.00000 0.00000 0.00000
March 506.00000 0.00000 0.00000 0.00000 0.00000
April 510.00000 0.00000 0.00000 0.00000 0.00000
May 515.00000 0.00000 0.00000 0.00000 0.00000
June 492.00000 0.00000 0.00000 0.00000 0.00000
July 533.00000 0.00000 0.00000 0.00000 0.00000
August 506.00000 0.00000 0.00000 0.00000 0.00000
September 510.00000 0.00000 0.00000 0.00000 0.00000
October 524.00000 0.00000 0.00000 0.00000 0.00000
November 510.00000 0.00000 0.00000 0.00000 0.00000
December 533.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 6145.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 473.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 533.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_TSW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 533.00000 0.00000 0.00000 0.00000 0.00000
February 473.00000 0.00000 0.00000 0.00000 0.00000
March 506.00000 0.00000 0.00000 0.00000 0.00000
April 510.00000 0.00000 0.00000 0.00000 0.00000
May 515.00000 0.00000 0.00000 0.00000 0.00000
June 492.00000 0.00000 0.00000 0.00000 0.00000
July 533.00000 0.00000 0.00000 0.00000 0.00000
August 506.00000 0.00000 0.00000 0.00000 0.00000
September 510.00000 0.00000 0.00000 0.00000 0.00000
October 524.00000 0.00000 0.00000 0.00000 0.00000
November 510.00000 0.00000 0.00000 0.00000 0.00000
December 533.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 6145.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 473.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 533.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_TNW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 744.00000 0.00000 0.00000 0.00000 0.00000
February 672.00000 0.00000 0.00000 0.00000 0.00000
March 744.00000 0.00000 0.00000 0.00000 0.00000
April 720.00000 0.00000 0.00000 0.00000 0.00000
May 744.00000 0.00000 0.00000 0.00000 0.00000
June 720.00000 0.00000 0.00000 0.00000 0.00000
July 744.00000 0.00000 0.00000 0.00000 0.00000
August 744.00000 0.00000 0.00000 0.00000 0.00000
September 720.00000 0.00000 0.00000 0.00000 0.00000
October 744.00000 0.00000 0.00000 0.00000 0.00000
November 720.00000 0.00000 0.00000 0.00000 0.00000
December 744.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 8760.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 672.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 744.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_TSE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 533.00000 0.00000 0.00000 0.00000 0.00000
February 473.00000 0.00000 0.00000 0.00000 0.00000
March 506.00000 0.00000 0.00000 0.00000 0.00000
April 510.00000 0.00000 0.00000 0.00000 0.00000
May 515.00000 0.00000 0.00000 0.00000 0.00000
June 492.00000 0.00000 0.00000 0.00000 0.00000
July 533.00000 0.00000 0.00000 0.00000 0.00000
August 506.00000 0.00000 0.00000 0.00000 0.00000
September 510.00000 0.00000 0.00000 0.00000 0.00000
October 524.00000 0.00000 0.00000 0.00000 0.00000
November 510.00000 0.00000 0.00000 0.00000 0.00000
December 533.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 6145.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 473.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 533.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_TNE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 744.00000 0.00000 0.00000 0.00000 0.00000
February 672.00000 0.00000 0.00000 0.00000 0.00000
March 744.00000 0.00000 0.00000 0.00000 0.00000
April 720.00000 0.00000 0.00000 0.00000 0.00000
May 744.00000 0.00000 0.00000 0.00000 0.00000
June 720.00000 0.00000 0.00000 0.00000 0.00000
July 744.00000 0.00000 0.00000 0.00000 0.00000
August 744.00000 0.00000 0.00000 0.00000 0.00000
September 720.00000 0.00000 0.00000 0.00000 0.00000
October 744.00000 0.00000 0.00000 0.00000 0.00000
November 720.00000 0.00000 0.00000 0.00000 0.00000
December 744.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 8760.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 672.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 744.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_TN1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 744.00000 0.00000 0.00000 0.00000 0.00000
February 672.00000 0.00000 0.00000 0.00000 0.00000
March 744.00000 0.00000 0.00000 0.00000 0.00000
April 720.00000 0.00000 0.00000 0.00000 0.00000
May 744.00000 0.00000 0.00000 0.00000 0.00000
June 720.00000 0.00000 0.00000 0.00000 0.00000
July 744.00000 0.00000 0.00000 0.00000 0.00000
August 744.00000 0.00000 0.00000 0.00000 0.00000
September 720.00000 0.00000 0.00000 0.00000 0.00000
October 744.00000 0.00000 0.00000 0.00000 0.00000
November 720.00000 0.00000 0.00000 0.00000 0.00000
December 744.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 8760.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 672.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 744.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_TN2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 744.00000 0.00000 0.00000 0.00000 0.00000
February 672.00000 0.00000 0.00000 0.00000 0.00000
March 744.00000 0.00000 0.00000 0.00000 0.00000
April 720.00000 0.00000 0.00000 0.00000 0.00000
May 744.00000 0.00000 0.00000 0.00000 0.00000
June 720.00000 0.00000 0.00000 0.00000 0.00000
July 744.00000 0.00000 0.00000 0.00000 0.00000
August 744.00000 0.00000 0.00000 0.00000 0.00000
September 720.00000 0.00000 0.00000 0.00000 0.00000
October 744.00000 0.00000 0.00000 0.00000 0.00000
November 720.00000 0.00000 0.00000 0.00000 0.00000
December 744.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 8760.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 672.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 744.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_TS1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 533.00000 0.00000 0.00000 0.00000 0.00000
February 473.00000 0.00000 0.00000 0.00000 0.00000
March 506.00000 0.00000 0.00000 0.00000 0.00000
April 510.00000 0.00000 0.00000 0.00000 0.00000
May 515.00000 0.00000 0.00000 0.00000 0.00000
June 492.00000 0.00000 0.00000 0.00000 0.00000
July 533.00000 0.00000 0.00000 0.00000 0.00000
August 506.00000 0.00000 0.00000 0.00000 0.00000
September 510.00000 0.00000 0.00000 0.00000 0.00000
October 524.00000 0.00000 0.00000 0.00000 0.00000
November 510.00000 0.00000 0.00000 0.00000 0.00000
December 533.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 6145.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 473.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 533.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_TS2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 533.00000 0.00000 0.00000 0.00000 0.00000
February 473.00000 0.00000 0.00000 0.00000 0.00000
March 506.00000 0.00000 0.00000 0.00000 0.00000
April 510.00000 0.00000 0.00000 0.00000 0.00000
May 515.00000 0.00000 0.00000 0.00000 0.00000
June 492.00000 0.00000 0.00000 0.00000 0.00000
July 533.00000 0.00000 0.00000 0.00000 0.00000
August 506.00000 0.00000 0.00000 0.00000 0.00000
September 510.00000 0.00000 0.00000 0.00000 0.00000
October 524.00000 0.00000 0.00000 0.00000 0.00000
November 510.00000 0.00000 0.00000 0.00000 0.00000
December 533.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 6145.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 473.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 533.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_T CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 744.00000 0.00000 0.00000 0.00000 0.00000
February 672.00000 0.00000 0.00000 0.00000 0.00000
March 744.00000 0.00000 0.00000 0.00000 0.00000
April 720.00000 0.00000 0.00000 0.00000 0.00000
May 744.00000 0.00000 0.00000 0.00000 0.00000
June 720.00000 0.00000 0.00000 0.00000 0.00000
July 744.00000 0.00000 0.00000 0.00000 0.00000
August 744.00000 0.00000 0.00000 0.00000 0.00000
September 720.00000 0.00000 0.00000 0.00000 0.00000
October 744.00000 0.00000 0.00000 0.00000 0.00000
November 720.00000 0.00000 0.00000 0.00000 0.00000
December 744.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 8760.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 672.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 744.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_G CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 744.00000 0.00000 0.00000 0.00000 0.00000
February 672.00000 0.00000 0.00000 0.00000 0.00000
March 744.00000 0.00000 0.00000 0.00000 0.00000
April 720.00000 0.00000 0.00000 0.00000 0.00000
May 744.00000 0.00000 0.00000 0.00000 0.00000
June 720.00000 0.00000 0.00000 0.00000 0.00000
July 744.00000 0.00000 0.00000 0.00000 0.00000
August 744.00000 0.00000 0.00000 0.00000 0.00000
September 720.00000 0.00000 0.00000 0.00000 0.00000
October 744.00000 0.00000 0.00000 0.00000 0.00000
November 720.00000 0.00000 0.00000 0.00000 0.00000
December 744.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 8760.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 672.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 744.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: OCCUP_M CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 744.00000 0.00000 0.00000 0.00000 0.00000
February 672.00000 0.00000 0.00000 0.00000 0.00000
March 744.00000 0.00000 0.00000 0.00000 0.00000
April 720.00000 0.00000 0.00000 0.00000 0.00000
May 744.00000 0.00000 0.00000 0.00000 0.00000
June 720.00000 0.00000 0.00000 0.00000 0.00000
July 744.00000 0.00000 0.00000 0.00000 0.00000
August 744.00000 0.00000 0.00000 0.00000 0.00000
September 720.00000 0.00000 0.00000 0.00000 0.00000
October 744.00000 0.00000 0.00000 0.00000 0.00000
November 720.00000 0.00000 0.00000 0.00000 0.00000
December 744.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 8760.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 672.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 744.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: DXReportMonthly

For: SPLIT GSW HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.103163E+10 0.257320E+09 481.76 0.102640E+10 5231302.92 0.00 1.00 02-JAN-13:12 0.00 01-JAN-00:10 5971.49 08-JAN-20:12 5654.54 08-JAN-13:22 1414.81 08-JAN-20:12 1242.52 31-JAN-17:01 0.00
February 0.183011E+09 45758422.82 133.59 0.182350E+09 661097.17 0.00 1.00 01-FEB-17:01 0.00 01-FEB-09:05 5563.83 24-FEB-17:01 5563.83 24-FEB-17:01 541.50 18-FEB-12:42 1213.42 24-FEB-17:01 0.00
March 0.308628E+09 77164512.14 160.92 0.307874E+09 754243.36 0.00 1.00 01-MAR-17:02 0.00 01-MAR-03:10 5643.36 18-MAR-10:12 5640.92 18-MAR-11:22 120.31 05-MAR-22:52 1271.26 20-MAR-16:01 0.00
April 0.197846E+10 0.520185E+09 533.37 0.197831E+10 150095.16 0.00 1.00 02-APR-09:32 0.00 01-APR-00:10 5610.61 16-APR-11:12 5610.61 16-APR-11:12 10.90 17-APR-03:10 1309.77 25-APR-16:01 0.00
May 0.226249E+10 0.609034E+09 565.55 0.226249E+10 -0.0 0.00 1.00 01-MAY-16:01 0.00 01-MAY-07:02 5556.42 11-MAY-07:32 5556.42 11-MAY-07:32 0.00 14-MAY-08:42 1315.63 10-MAY-16:01 0.00
June 0.332115E+10 0.928774E+09 640.34 0.331610E+10 5053533.48 0.00 1.00 01-JUN-06:52 0.00 01-JUN-05:15 5587.66 04-JUN-06:42 5587.66 04-JUN-06:42 186.25 17-JUN-17:10 1390.25 30-JUN-16:01 0.00
July 0.404210E+10 0.108648E+10 697.17 0.374527E+10 0.296825E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 6021.19 15-JUL-06:42 5516.35 06-JUL-06:52 1635.07 15-JUL-06:43 1434.66 18-JUL-16:01 0.00
August 0.409925E+10 0.109073E+10 677.90 0.381091E+10 0.288343E+09 0.00 1.00 01-AUG-16:01 0.00 01-AUG-08:62 6031.61 05-AUG-21:52 5613.70 23-AUG-07:22 1672.01 05-AUG-09:13 1418.05 11-AUG-16:01 0.00
September 0.406857E+10 0.105320E+10 632.13 0.378379E+10 0.284774E+09 0.00 1.00 01-SEP-06:52 0.00 01-SEP-05:13 6250.49 03-SEP-10:42 5636.50 20-SEP-06:01 2601.85 03-SEP-10:43 1404.25 06-SEP-16:01 0.00
October 0.270895E+10 0.688004E+09 565.35 0.265300E+10 55941869.01 0.00 1.00 01-OCT-07:32 0.00 01-OCT-05:13 5943.88 03-OCT-07:22 5759.91 07-OCT-15:52 1312.72 03-OCT-07:23 1388.54 03-OCT-16:01 0.00
November 0.163283E+10 0.404552E+09 519.09 0.158552E+10 47303123.74 0.00 1.00 01-NOV-16:01 0.00 01-NOV-05:13 6218.68 12-NOV-22:52 5659.25 02-NOV-19:02 2437.42 12-NOV-22:53 1279.02 01-NOV-16:01 0.00
December 0.925447E+09 0.232291E+09 426.83 0.925348E+09 98877.74 0.00 1.00 01-DEC-17:01 0.00 01-DEC-09:05 5569.84 13-DEC-17:01 5569.84 13-DEC-17:01 16.29 13-DEC-09:00 1214.05 13-DEC-17:01 0.00
                                       
Annual Sum or Average 0.265625E+11 0.699349E+10 6034.00 0.255774E+11 0.985136E+09 0.00                         0.00
Minimum of Months 0.183011E+09 45758422.82 133.59 0.182350E+09 -0.0 0.00 1.00   0.00   5556.42   5516.35   0.00   1213.42   0.00
Maximum of Months 0.409925E+10 0.109073E+10 697.17 0.381091E+10 0.296825E+09 0.00 1.00   0.00   6250.49   5759.91   2601.85   1434.66   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT GNW HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.125760E+09 32493464.15 83.18 0.125291E+09 469196.47 0.00 1.00 18-JAN-14:42 0.00 01-JAN-00:10 5334.73 26-JAN-14:42 5334.73 26-JAN-14:42 1162.97 08-JAN-20:12 1180.12 26-JAN-14:42 0.00
February 3390549.46 866667.84 6.91 3390549.46 -0.0 0.00 0.63 01-FEB-17:12 0.00 01-FEB-00:20 3131.84 01-FEB-17:12 3131.84 01-FEB-17:12 0.00 01-FEB-17:50 740.58 01-FEB-17:12 0.00
March 0.137931E+09 35904587.31 86.51 0.137910E+09 21125.16 0.00 1.00 17-MAR-20:02 0.00 01-MAR-00:10 5443.90 17-MAR-21:52 5443.90 17-MAR-21:52 17.89 18-MAR-11:32 1201.33 21-MAR-11:52 0.00
April 0.162594E+10 0.436798E+09 538.27 0.162585E+10 95279.79 0.00 1.00 03-APR-09:42 0.00 01-APR-00:10 5482.39 16-APR-21:32 5482.39 16-APR-21:32 7.61 17-APR-03:10 1227.29 16-APR-13:42 0.00
May 0.239466E+10 0.655720E+09 637.49 0.239466E+10 0.00 0.00 1.00 01-MAY-10:42 0.00 01-MAY-07:02 5435.55 11-MAY-08:62 5435.55 11-MAY-08:62 0.00 13-MAY-10:32 1223.85 18-MAY-08:12 0.00
June 0.367754E+10 0.104207E+10 677.47 0.367239E+10 5146487.38 0.00 1.00 01-JUN-07:22 0.00 01-JUN-05:15 5491.48 04-JUN-06:42 5491.48 04-JUN-06:42 150.02 17-JUN-18:30 1242.07 23-JUN-07:02 0.00
July 0.426956E+10 0.116320E+10 722.29 0.395672E+10 0.312843E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 5960.86 15-JUL-06:42 5391.39 06-JUL-07:12 1771.16 15-JUL-06:43 1267.03 29-JUL-08:12 0.00
August 0.413620E+10 0.112158E+10 696.51 0.382973E+10 0.306474E+09 0.00 1.00 03-AUG-19:12 0.00 03-AUG-17:42 5984.06 05-AUG-21:52 5427.51 23-AUG-08:12 1830.25 05-AUG-21:53 1265.75 10-AUG-07:12 0.00
September 0.378105E+10 0.996258E+09 634.33 0.348751E+10 0.293535E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-05:13 6138.39 03-SEP-11:22 5531.33 20-SEP-06:01 2471.16 03-SEP-11:23 1276.53 12-SEP-07:52 0.00
October 0.190791E+10 0.498119E+09 506.99 0.185275E+10 55161125.92 0.00 1.00 01-OCT-07:42 0.00 01-OCT-05:13 5875.42 03-OCT-08:62 5550.92 21-OCT-20:02 1520.74 03-OCT-08:03 1263.07 03-OCT-08:62 0.00
November 0.651917E+09 0.164174E+09 331.75 0.616664E+09 35252207.38 0.00 1.00 01-NOV-11:12 0.00 01-NOV-05:13 6085.35 12-NOV-22:52 5548.84 11-NOV-13:02 2345.74 12-NOV-22:53 1230.89 01-NOV-11:12 0.00
December 88818552.31 22729889.58 89.01 88815436.13 3116.18 0.00 1.00 01-DEC-19:12 0.00 01-DEC-01:10 5332.34 27-DEC-19:02 5332.34 27-DEC-19:02 1.23 13-DEC-13:20 1189.09 25-DEC-13:12 0.00
                                       
Annual Sum or Average 0.228007E+11 0.616991E+10 5010.72 0.217917E+11 0.100900E+10 0.00                         0.00
Minimum of Months 3390549.46 866667.84 6.91 3390549.46 -0.0 0.00 0.63   0.00   3131.84   3131.84   0.00   740.58   0.00
Maximum of Months 0.426956E+10 0.116320E+10 722.29 0.395672E+10 0.312843E+09 0.00 1.00   0.00   6138.39   5550.92   2471.16   1276.53   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT OFFICE HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.112513E+10 0.281113E+09 191.44 0.112209E+10 3047684.83 0.00 1.00 17-JAN-07:01 0.00 01-JAN-00:10 6285.69 17-JAN-07:01 6285.69 17-JAN-07:01 234.12 09-JAN-07:01 1407.42 17-JAN-07:01 0.00
February 0.466751E+09 0.117927E+09 155.83 0.455844E+09 10906770.44 0.00 0.34 01-FEB-14:00 0.00 01-FEB-00:10 1952.21 01-FEB-14:00 1952.21 01-FEB-14:00 135.10 16-FEB-12:00 485.34 01-FEB-14:00 0.00
March 0.681168E+09 0.173390E+09 194.11 0.678119E+09 3048809.69 0.00 0.93 21-MAR-06:01 0.00 01-MAR-00:10 5908.99 21-MAR-06:01 5908.99 21-MAR-06:01 108.62 06-MAR-13:40 1328.25 21-MAR-06:01 0.00
April 0.183781E+10 0.475000E+09 226.94 0.183781E+10 0.00 0.00 1.00 03-APR-06:01 0.00 01-APR-00:10 6637.01 25-APR-06:01 6637.01 25-APR-06:01 0.00 05-APR-08:70 1449.82 25-APR-06:01 0.00
May 0.231068E+10 0.612091E+09 276.56 0.231068E+10 -0.0 0.00 1.00 01-MAY-06:01 0.00 01-MAY-00:10 6674.36 11-MAY-06:01 6674.36 11-MAY-06:01 0.00 21-MAY-16:15 1453.39 11-MAY-06:01 0.00
June 0.331500E+10 0.915795E+09 426.63 0.331255E+10 2454235.03 0.00 1.00 01-JUN-06:01 0.00 01-JUN-00:10 6795.00 30-JUN-06:01 6795.00 30-JUN-06:01 249.37 30-JUN-08:20 1549.03 30-JUN-06:01 0.00
July 0.362041E+10 0.960266E+09 504.30 0.339380E+10 0.226611E+09 0.00 1.00 03-JUL-06:01 0.00 01-JUL-00:10 7676.35 14-JUL-06:01 6983.99 11-JUL-06:01 3402.68 14-JUL-06:08 1561.47 12-JUL-06:01 0.00
August 0.401077E+10 0.105915E+10 457.40 0.377256E+10 0.238202E+09 0.00 1.00 01-AUG-06:01 0.00 01-AUG-01:30 7418.50 01-AUG-06:01 6999.04 21-AUG-06:01 2357.84 01-AUG-06:07 1583.37 16-AUG-06:01 0.00
September 0.352539E+10 0.901349E+09 435.19 0.329835E+10 0.227042E+09 0.00 1.00 01-SEP-06:01 0.00 01-SEP-00:10 7397.06 05-SEP-06:01 6850.33 20-SEP-06:01 2297.95 05-SEP-06:06 1524.15 07-SEP-06:01 0.00
October 0.250212E+10 0.628977E+09 295.40 0.245946E+10 42667300.93 0.00 1.00 02-OCT-06:01 0.00 01-OCT-00:40 7393.28 03-OCT-06:01 7027.27 02-OCT-06:01 2353.69 03-OCT-06:06 1501.16 02-OCT-06:01 0.00
November 0.158785E+10 0.391192E+09 202.85 0.155808E+10 29762851.06 0.00 1.00 01-NOV-06:01 0.00 01-NOV-00:10 7032.97 14-NOV-07:01 6756.26 01-NOV-06:01 1767.36 14-NOV-07:02 1478.42 14-NOV-07:01 0.00
December 0.870557E+09 0.218580E+09 177.18 0.869424E+09 1132571.20 0.00 1.00 26-DEC-07:01 0.00 01-DEC-00:10 6285.69 26-DEC-07:01 6285.69 26-DEC-07:01 94.77 13-DEC-10:50 1407.42 26-DEC-07:01 0.00
                                       
Annual Sum or Average 0.258536E+11 0.673484E+10 3543.83 0.250688E+11 0.784876E+09 0.00                         0.00
Minimum of Months 0.466751E+09 0.117927E+09 155.83 0.455844E+09 -0.0 0.00 0.34   0.00   1952.21   1952.21   0.00   485.34   0.00
Maximum of Months 0.401077E+10 0.105915E+10 504.30 0.377256E+10 0.238202E+09 0.00 1.00   0.00   7676.35   7027.27   3402.68   1583.37   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT GNE HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.107937E+09 27919449.26 83.59 0.107465E+09 472496.81 0.00 1.00 17-JAN-13:42 0.00 01-JAN-00:10 4959.90 26-JAN-14:42 4959.90 26-JAN-14:42 984.17 08-JAN-20:12 1110.17 31-JAN-13:02 0.00
February 2938571.95 759319.77 6.26 2938571.95 -0.0 0.00 0.30 01-FEB-17:12 0.00 01-FEB-00:20 1303.42 01-FEB-17:12 1303.42 01-FEB-17:12 0.00 01-FEB-13:20 325.76 01-FEB-17:12 0.00
March 0.136082E+09 35382451.34 87.17 0.136045E+09 36655.14 0.00 1.00 16-MAR-11:12 0.00 01-MAR-00:10 5101.73 18-MAR-11:32 5101.73 18-MAR-11:32 27.43 18-MAR-11:38 1134.27 17-MAR-11:22 0.00
April 0.163310E+10 0.437440E+09 547.44 0.163301E+10 87673.24 0.00 1.00 02-APR-09:32 0.00 01-APR-00:10 5109.57 16-APR-12:22 5109.57 16-APR-12:22 7.25 17-APR-03:20 1141.21 16-APR-13:42 0.00
May 0.243412E+10 0.663463E+09 647.55 0.243412E+10 -0.0 0.00 1.00 01-MAY-10:42 0.00 01-MAY-07:02 5073.61 11-MAY-08:62 5073.61 11-MAY-08:62 0.00 14-MAY-08:43 1139.51 18-MAY-08:12 0.00
June 0.372564E+10 0.104985E+10 678.86 0.372032E+10 5318771.05 0.00 1.00 01-JUN-07:22 0.00 01-JUN-05:15 5102.59 04-JUN-06:42 5102.59 04-JUN-06:42 144.27 17-JUN-18:30 1154.09 23-JUN-07:02 0.00
July 0.440104E+10 0.119159E+10 722.42 0.408257E+10 0.318471E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 5535.70 15-JUL-06:42 5009.11 06-JUL-07:12 1627.20 15-JUL-06:43 1176.41 29-JUL-08:12 0.00
August 0.425704E+10 0.114700E+10 696.72 0.394422E+10 0.312821E+09 0.00 1.00 03-AUG-19:12 0.00 03-AUG-17:42 5559.34 05-AUG-21:52 5043.55 23-AUG-08:12 1692.58 05-AUG-21:53 1175.39 10-AUG-07:12 0.00
September 0.384205E+10 0.100676E+10 634.76 0.354343E+10 0.298625E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-05:13 5701.32 03-SEP-11:22 5138.93 20-SEP-06:01 2284.57 03-SEP-11:23 1185.57 12-SEP-07:52 0.00
October 0.194297E+10 0.505370E+09 509.34 0.188632E+10 56654301.70 0.00 1.00 01-OCT-07:42 0.00 01-OCT-05:13 5451.33 03-OCT-08:62 5166.14 21-OCT-21:52 1450.22 03-OCT-08:13 1173.17 03-OCT-08:62 0.00
November 0.616017E+09 0.155129E+09 336.77 0.582459E+09 33557909.59 0.00 1.00 01-NOV-11:12 0.00 01-NOV-05:13 5650.85 12-NOV-22:52 5155.43 01-NOV-19:52 2181.69 12-NOV-22:53 1143.25 01-NOV-11:12 0.00
December 87060013.66 22326577.33 96.31 87020326.51 39687.15 0.00 1.00 01-DEC-19:12 0.00 01-DEC-01:20 4940.24 27-DEC-19:02 4940.24 27-DEC-19:02 6.05 13-DEC-12:00 1106.16 25-DEC-13:12 0.00
                                       
Annual Sum or Average 0.231860E+11 0.624299E+10 5047.21 0.221599E+11 0.102608E+10 0.00                         0.00
Minimum of Months 2938571.95 759319.77 6.26 2938571.95 -0.0 0.00 0.30   0.00   1303.42   1303.42   0.00   325.76   0.00
Maximum of Months 0.440104E+10 0.119159E+10 722.42 0.408257E+10 0.318471E+09 0.00 1.00   0.00   5701.32   5166.14   2284.57   1185.57   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT GN1 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.164710E+09 42241680.44 191.91 0.163472E+09 1238589.62 0.00 1.00 08-JAN-20:12 0.00 01-JAN-00:10 4651.23 08-JAN-20:12 4309.56 20-JAN-20:42 1218.68 08-JAN-20:12 969.83 08-JAN-20:12 0.00
February 8895695.91 2292753.82 23.10 8846633.50 49062.41 0.00 0.64 01-FEB-17:12 0.00 01-FEB-03:00 2536.85 01-FEB-17:12 2536.85 01-FEB-17:12 113.82 18-FEB-19:12 599.16 01-FEB-17:12 0.00
March 0.167455E+09 43324037.81 154.78 0.167359E+09 96532.74 0.00 1.00 16-MAR-11:12 0.00 01-MAR-00:10 4365.36 18-MAR-11:32 4365.36 18-MAR-11:32 20.08 18-MAR-11:38 972.98 17-MAR-11:22 0.00
April 0.138027E+10 0.369209E+09 546.26 0.138016E+10 107358.40 0.00 1.00 03-APR-09:42 0.00 01-APR-00:10 4360.41 16-APR-12:22 4360.41 16-APR-12:22 8.53 17-APR-03:30 976.64 16-APR-13:42 0.00
May 0.203289E+10 0.553662E+09 638.38 0.203289E+10 0.00 0.00 1.00 01-MAY-10:42 0.00 01-MAY-07:02 4334.32 11-MAY-08:62 4334.32 11-MAY-08:62 0.00 06-MAY-08:43 975.36 18-MAY-08:12 0.00
June 0.299190E+10 0.844943E+09 677.03 0.298702E+10 4874305.11 0.00 1.00 01-JUN-07:22 0.00 01-JUN-05:15 4374.38 04-JUN-06:42 4374.38 04-JUN-06:42 128.39 17-JUN-18:40 989.85 23-JUN-07:02 0.00
July 0.356081E+10 0.964716E+09 722.37 0.326998E+10 0.290830E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 4751.70 15-JUL-06:42 4295.77 06-JUL-07:12 1415.86 15-JUL-06:43 1009.36 29-JUL-08:12 0.00
August 0.342963E+10 0.924339E+09 696.16 0.314346E+10 0.286170E+09 0.00 1.00 03-AUG-19:12 0.00 03-AUG-17:42 4766.49 05-AUG-21:52 4322.83 23-AUG-08:12 1451.31 04-AUG-09:15 1008.42 10-AUG-07:12 0.00
September 0.315381E+10 0.826196E+09 635.38 0.288107E+10 0.272737E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-05:13 4892.45 03-SEP-11:22 4405.35 20-SEP-07:52 2012.54 03-SEP-11:25 1017.16 12-SEP-08:62 0.00
October 0.167166E+10 0.434037E+09 509.54 0.161915E+10 52513566.20 0.00 1.00 01-OCT-07:42 0.00 01-OCT-05:13 4686.39 03-OCT-08:62 4422.55 21-OCT-21:52 1317.22 03-OCT-08:13 1007.37 03-OCT-08:13 0.00
November 0.675608E+09 0.169773E+09 395.68 0.639275E+09 36333485.28 0.00 1.00 01-NOV-11:12 0.00 01-NOV-05:13 4855.84 12-NOV-22:52 4422.35 01-NOV-19:52 1892.29 12-NOV-22:55 980.63 01-NOV-11:12 0.00
December 0.147343E+09 37797935.08 188.93 0.147256E+09 87015.43 0.00 1.00 01-DEC-19:12 0.00 01-DEC-09:40 4259.57 03-DEC-19:12 4259.57 03-DEC-19:12 9.97 13-DEC-11:50 948.06 25-DEC-13:12 0.00
                                       
Annual Sum or Average 0.193850E+11 0.521253E+10 5379.53 0.184400E+11 0.945036E+09 0.00                         0.00
Minimum of Months 8895695.91 2292753.82 23.10 8846633.50 0.00 0.00 0.64   0.00   2536.85   2536.85   0.00   599.16   0.00
Maximum of Months 0.356081E+10 0.964716E+09 722.37 0.326998E+10 0.290830E+09 0.00 1.00   0.00   4892.45   4422.55   2012.54   1017.16   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT GN2 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.164940E+09 42304676.04 191.89 0.163733E+09 1206288.33 0.00 1.00 08-JAN-20:12 0.00 01-JAN-00:10 4643.44 08-JAN-20:12 4302.52 20-JAN-20:42 1218.35 08-JAN-20:12 968.29 08-JAN-20:12 0.00
February 9274635.82 2389157.77 23.79 9208305.05 66330.77 0.00 0.64 01-FEB-17:12 0.00 01-FEB-03:00 2534.88 01-FEB-17:12 2534.88 01-FEB-17:12 141.05 18-FEB-19:12 598.65 01-FEB-17:12 0.00
March 0.169421E+09 43825279.02 155.37 0.169322E+09 99204.92 0.00 1.00 16-MAR-11:12 0.00 01-MAR-00:10 4359.24 18-MAR-11:32 4359.24 18-MAR-11:32 27.16 05-MAR-22:52 971.51 17-MAR-11:22 0.00
April 0.138649E+10 0.370811E+09 547.09 0.138638E+10 107920.58 0.00 1.00 03-APR-09:42 0.00 01-APR-00:10 4355.28 16-APR-12:22 4355.28 16-APR-12:22 8.57 17-APR-03:30 975.23 16-APR-13:42 0.00
May 0.203884E+10 0.555189E+09 638.54 0.203884E+10 -0.0 0.00 1.00 01-MAY-10:42 0.00 01-MAY-07:02 4328.11 11-MAY-08:62 4328.11 11-MAY-08:62 0.00 07-MAY-08:32 973.93 18-MAY-08:12 0.00
June 0.299512E+10 0.845750E+09 677.31 0.299024E+10 4879138.18 0.00 1.00 01-JUN-07:22 0.00 01-JUN-05:15 4367.57 04-JUN-06:42 4367.57 04-JUN-06:42 128.37 17-JUN-18:40 988.29 23-JUN-07:02 0.00
July 0.356666E+10 0.966147E+09 722.43 0.327560E+10 0.291059E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 4744.23 15-JUL-06:42 4288.99 06-JUL-07:12 1412.97 15-JUL-06:43 1007.77 29-JUL-08:12 0.00
August 0.343552E+10 0.925767E+09 696.25 0.314909E+10 0.286424E+09 0.00 1.00 03-AUG-19:12 0.00 03-AUG-17:42 4758.89 05-AUG-21:52 4316.02 23-AUG-08:12 1456.12 04-AUG-09:15 1006.79 10-AUG-07:12 0.00
September 0.315757E+10 0.827065E+09 635.22 0.288465E+10 0.272925E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-05:13 4884.66 03-SEP-11:22 4398.40 20-SEP-07:52 2008.87 03-SEP-11:25 1015.54 12-SEP-08:62 0.00
October 0.167707E+10 0.435372E+09 509.79 0.162448E+10 52590685.19 0.00 1.00 01-OCT-07:42 0.00 01-OCT-05:13 4678.80 03-OCT-08:62 4415.62 21-OCT-21:52 1314.46 03-OCT-08:13 1005.77 03-OCT-08:13 0.00
November 0.672475E+09 0.168990E+09 395.36 0.636134E+09 36340564.34 0.00 1.00 01-NOV-11:12 0.00 01-NOV-05:13 4848.03 12-NOV-22:52 4415.37 01-NOV-19:52 1889.55 12-NOV-22:55 979.08 01-NOV-11:12 0.00
December 0.148031E+09 37973891.65 190.20 0.147940E+09 91403.57 0.00 1.00 01-DEC-19:12 0.00 01-DEC-09:40 4252.98 03-DEC-19:12 4252.98 03-DEC-19:12 10.36 13-DEC-11:50 946.64 25-DEC-13:12 0.00
                                       
Annual Sum or Average 0.194214E+11 0.522158E+10 5383.23 0.184756E+11 0.945790E+09 0.00                         0.00
Minimum of Months 9274635.82 2389157.77 23.79 9208305.05 -0.0 0.00 0.64   0.00   2534.88   2534.88   0.00   598.65   0.00
Maximum of Months 0.356666E+10 0.966147E+09 722.43 0.327560E+10 0.291059E+09 0.00 1.00   0.00   4884.66   4415.62   2008.87   1015.54   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT GS1 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.132448E+10 0.329291E+09 528.62 0.131722E+10 7263827.73 0.00 1.00 02-JAN-13:12 0.00 01-JAN-00:10 4779.81 08-JAN-20:12 4520.55 08-JAN-13:22 1137.75 08-JAN-20:13 993.19 31-JAN-17:01 0.00
February 0.401953E+09 0.100609E+09 323.27 0.393212E+09 8741033.15 0.00 1.00 01-FEB-17:01 0.00 01-FEB-09:05 4614.86 18-FEB-19:12 4447.77 24-FEB-17:01 634.62 18-FEB-19:12 983.03 18-FEB-19:12 0.00
March 0.466074E+09 0.116388E+09 278.05 0.463178E+09 2895732.54 0.00 1.00 01-MAR-17:02 0.00 01-MAR-09:05 4522.35 18-MAR-10:12 4515.50 18-MAR-10:12 276.74 06-MAR-18:42 1015.17 20-MAR-16:01 0.00
April 0.178497E+10 0.465667E+09 538.08 0.178477E+10 193783.10 0.00 1.00 01-APR-09:42 0.00 01-APR-04:40 4485.62 16-APR-11:12 4485.62 16-APR-11:12 13.31 17-APR-03:10 1046.50 25-APR-16:01 0.00
May 0.194856E+10 0.519898E+09 550.25 0.194856E+10 0.00 0.00 1.00 01-MAY-16:01 0.00 01-MAY-07:02 4445.90 11-MAY-07:32 4445.90 11-MAY-07:32 0.00 09-MAY-16:02 1051.31 10-MAY-16:01 0.00
June 0.268904E+10 0.746586E+09 624.72 0.268416E+10 4885325.12 0.00 1.00 01-JUN-06:52 0.00 01-JUN-05:15 4464.20 04-JUN-06:42 4464.20 04-JUN-06:42 162.53 17-JUN-17:10 1111.21 30-JUN-16:01 0.00
July 0.339291E+10 0.903887E+09 682.78 0.311568E+10 0.277223E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 4823.85 15-JUL-06:42 4407.17 06-JUL-06:52 1349.01 15-JUL-06:43 1150.46 18-JUL-16:01 0.00
August 0.345835E+10 0.911259E+09 670.74 0.318774E+10 0.270617E+09 0.00 1.00 01-AUG-16:01 0.00 01-AUG-08:62 4816.70 05-AUG-21:52 4481.85 23-AUG-07:22 1318.99 05-AUG-09:13 1137.44 01-AUG-16:01 0.00
September 0.350120E+10 0.898216E+09 629.72 0.323428E+10 0.266920E+09 0.00 1.00 01-SEP-06:52 0.00 01-SEP-05:13 4996.44 03-SEP-10:42 4503.65 20-SEP-06:01 2118.75 03-SEP-10:45 1123.13 06-SEP-16:01 0.00
October 0.252154E+10 0.634843E+09 572.73 0.246745E+10 54087526.91 0.00 1.00 01-OCT-07:32 0.00 01-OCT-05:13 4749.24 03-OCT-07:22 4541.75 07-OCT-15:52 1038.37 03-OCT-07:23 1111.38 03-OCT-16:01 0.00
November 0.173782E+10 0.427856E+09 529.28 0.168889E+10 48924345.38 0.00 1.00 01-NOV-16:01 0.00 01-NOV-05:13 4956.27 12-NOV-22:52 4521.25 02-NOV-19:02 1955.07 12-NOV-22:55 1021.38 01-NOV-16:01 0.00
December 0.124236E+10 0.311123E+09 528.86 0.124192E+10 439631.15 0.00 1.00 01-DEC-17:01 0.00 01-DEC-09:05 4444.04 13-DEC-17:01 4444.04 13-DEC-17:01 28.31 13-DEC-09:00 969.32 13-DEC-17:01 0.00
                                       
Annual Sum or Average 0.244693E+11 0.636562E+10 6457.09 0.235271E+11 0.942192E+09 0.00                         0.00
Minimum of Months 0.401953E+09 0.100609E+09 278.05 0.393212E+09 0.00 0.00 1.00   0.00   4444.04   4407.17   0.00   969.32   0.00
Maximum of Months 0.350120E+10 0.911259E+09 682.78 0.323428E+10 0.277223E+09 0.00 1.00   0.00   4996.44   4541.75   2118.75   1150.46   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT GS2 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.131911E+10 0.328006E+09 523.78 0.131186E+10 7258443.80 0.00 1.00 02-JAN-13:12 0.00 01-JAN-00:10 4877.22 08-JAN-20:12 4616.11 08-JAN-13:22 1144.77 08-JAN-20:13 1014.24 31-JAN-17:01 0.00
February 0.390982E+09 97883794.41 315.30 0.382448E+09 8533794.25 0.00 1.00 01-FEB-17:01 0.00 01-FEB-09:05 4713.35 18-FEB-19:12 4541.09 24-FEB-17:01 645.44 18-FEB-19:12 1003.91 18-FEB-19:12 0.00
March 0.475441E+09 0.118736E+09 277.11 0.472552E+09 2889853.32 0.00 1.00 01-MAR-17:02 0.00 01-MAR-09:05 4619.41 18-MAR-10:12 4617.23 18-MAR-10:12 283.57 06-MAR-18:42 1037.03 20-MAR-16:01 0.00
April 0.190146E+10 0.495300E+09 548.16 0.190124E+10 220501.09 0.00 1.00 01-APR-09:42 0.00 01-APR-04:40 4578.06 16-APR-11:12 4578.06 16-APR-11:12 15.16 17-APR-03:10 1068.71 25-APR-16:01 0.00
May 0.210948E+10 0.561493E+09 566.86 0.210948E+10 0.00 0.00 1.00 01-MAY-16:01 0.00 01-MAY-07:02 4543.45 11-MAY-07:32 4543.45 11-MAY-07:32 0.00 02-MAY-16:01 1073.64 10-MAY-16:01 0.00
June 0.290878E+10 0.804848E+09 636.39 0.290373E+10 5047224.40 0.00 1.00 01-JUN-06:52 0.00 01-JUN-05:15 4559.04 04-JUN-06:42 4559.04 04-JUN-06:42 167.63 17-JUN-17:10 1134.77 30-JUN-16:01 0.00
July 0.366895E+10 0.974687E+09 691.90 0.338351E+10 0.285439E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 4903.59 15-JUL-06:42 4500.94 06-JUL-06:52 1286.17 15-JUL-06:43 1173.71 18-JUL-16:01 0.00
August 0.370086E+10 0.972700E+09 675.78 0.342288E+10 0.277983E+09 0.00 1.00 01-AUG-16:01 0.00 01-AUG-08:62 4913.49 05-AUG-21:52 4579.46 23-AUG-07:22 1314.67 05-AUG-09:13 1160.53 01-AUG-16:01 0.00
September 0.373757E+10 0.956180E+09 632.55 0.346334E+10 0.274229E+09 0.00 1.00 01-SEP-06:52 0.00 01-SEP-05:13 5083.13 03-SEP-10:42 4598.58 20-SEP-06:01 2087.72 03-SEP-10:45 1146.64 06-SEP-16:01 0.00
October 0.266778E+10 0.670477E+09 573.46 0.261185E+10 55936430.55 0.00 1.00 01-OCT-07:32 0.00 01-OCT-05:13 4841.79 03-OCT-07:22 4668.95 07-OCT-15:52 1026.91 03-OCT-07:23 1134.46 03-OCT-16:01 0.00
November 0.176278E+10 0.434087E+09 528.97 0.171327E+10 49510807.23 0.00 1.00 01-NOV-16:01 0.00 01-NOV-05:13 5059.58 12-NOV-22:52 4617.67 18-NOV-13:52 1991.77 12-NOV-22:55 1043.00 01-NOV-16:01 0.00
December 0.122901E+10 0.307812E+09 522.75 0.122858E+10 425052.42 0.00 1.00 01-DEC-17:01 0.00 01-DEC-09:05 4536.75 13-DEC-17:01 4536.75 13-DEC-17:01 28.28 13-DEC-09:00 989.73 13-DEC-17:01 0.00
                                       
Annual Sum or Average 0.258722E+11 0.672221E+10 6493.00 0.249047E+11 0.967473E+09 0.00                         0.00
Minimum of Months 0.390982E+09 97883794.41 277.11 0.382448E+09 0.00 0.00 1.00   0.00   4536.75   4500.94   0.00   989.73   0.00
Maximum of Months 0.373757E+10 0.974687E+09 691.90 0.346334E+10 0.285439E+09 0.00 1.00   0.00   5083.13   4668.95   2087.72   1173.71   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT MSW HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.306607E+10 0.763359E+09 523.26 0.305348E+10 12595000.41 0.00 1.00 02-JAN-13:12 0.00 01-JAN-00:10 13581.09 08-JAN-20:12 12895.97 22-JAN-15:52 2936.49 08-JAN-20:12 2829.53 31-JAN-17:01 0.00
February 0.143317E+10 0.357415E+09 389.59 0.139038E+10 42787231.45 0.00 1.00 01-FEB-17:01 0.00 01-FEB-09:05 13228.33 18-FEB-19:12 12879.80 13-FEB-17:01 1719.01 18-FEB-19:12 2806.05 18-FEB-19:12 0.00
March 0.198375E+10 0.495617E+09 384.51 0.197240E+10 11351217.21 0.00 1.00 01-MAR-17:02 0.00 01-MAR-09:05 12896.74 05-MAR-22:52 12891.68 18-MAR-10:12 750.77 06-MAR-18:42 2894.16 20-MAR-16:01 0.00
April 0.548738E+10 0.143378E+10 563.22 0.548708E+10 296915.16 0.00 1.00 01-APR-09:42 0.00 01-APR-07:00 12761.07 16-APR-11:12 12761.07 16-APR-11:12 23.50 17-APR-03:10 2981.67 25-APR-16:01 0.00
May 0.609659E+10 0.163146E+10 592.22 0.609659E+10 -0.0 0.00 1.00 01-MAY-16:01 0.00 01-MAY-07:02 12652.38 11-MAY-07:32 12652.38 11-MAY-07:32 0.00 11-MAY-07:32 2994.46 10-MAY-16:01 0.00
June 0.782072E+10 0.218506E+10 639.42 0.781036E+10 10357383.29 0.00 1.00 01-JUN-06:52 0.00 01-JUN-05:15 12713.82 04-JUN-06:42 12713.82 04-JUN-06:42 409.56 17-JUN-17:10 3164.88 30-JUN-16:01 0.00
July 0.827522E+10 0.223798E+10 677.68 0.766817E+10 0.607044E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 13803.58 15-JUL-06:42 12563.86 06-JUL-06:52 4134.16 15-JUL-06:43 3266.64 18-JUL-16:01 0.00
August 0.803843E+10 0.215694E+10 659.62 0.745923E+10 0.579201E+09 0.00 1.00 01-AUG-16:01 0.00 01-AUG-08:62 13839.43 05-AUG-20:52 12754.56 23-AUG-07:22 4253.63 05-AUG-20:53 3228.55 11-AUG-16:01 0.00
September 0.742771E+10 0.194701E+10 615.54 0.687260E+10 0.555108E+09 0.00 1.00 01-SEP-06:52 0.00 01-SEP-05:13 14335.63 03-SEP-10:42 12790.88 20-SEP-06:01 6280.93 03-SEP-10:43 3197.86 06-SEP-16:01 0.00
October 0.494581E+10 0.126755E+10 553.37 0.484067E+10 0.105140E+09 0.00 1.00 01-OCT-07:32 0.00 01-OCT-05:13 13679.68 03-OCT-07:22 12883.60 21-OCT-20:42 3616.88 03-OCT-07:23 3162.74 03-OCT-16:01 0.00
November 0.300771E+10 0.746692E+09 500.33 0.292367E+10 84039044.41 0.00 1.00 01-NOV-16:01 0.00 01-NOV-05:13 14002.98 13-NOV-22:52 12887.83 02-NOV-19:02 5057.11 12-NOV-22:52 2911.71 01-NOV-16:01 0.00
December 0.193805E+10 0.485706E+09 395.38 0.193801E+10 31751.64 0.00 1.00 01-DEC-17:01 0.00 01-DEC-09:05 12698.89 13-DEC-17:01 12698.89 13-DEC-17:01 25.86 13-DEC-09:00 2765.71 13-DEC-17:01 0.00
                                       
Annual Sum or Average 0.595206E+11 0.157086E+11 6494.14 0.575126E+11 0.200795E+10 0.00                         0.00
Minimum of Months 0.143317E+10 0.357415E+09 384.51 0.139038E+10 -0.0 0.00 1.00   0.00   12652.38   12563.86   0.00   2765.71   0.00
Maximum of Months 0.827522E+10 0.223798E+10 677.68 0.781036E+10 0.607044E+09 0.00 1.00   0.00   14335.63   12895.97   6280.93   3266.64   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT MNW HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.647220E+09 0.165478E+09 194.01 0.641456E+09 5764069.39 0.00 1.00 07-JAN-22:52 0.00 01-JAN-00:10 13396.19 08-JAN-20:12 12473.12 07-JAN-22:52 3363.44 08-JAN-20:12 2781.68 08-JAN-20:12 0.00
February 0.235888E+09 59460041.11 159.14 0.223702E+09 12185918.52 0.00 1.00 16-FEB-20:12 0.00 01-FEB-02:70 12958.84 18-FEB-19:12 12470.23 22-FEB-20:32 1707.81 18-FEB-19:12 2762.22 18-FEB-19:12 0.00
March 0.109441E+10 0.279610E+09 279.10 0.108819E+10 6223643.57 0.00 1.00 02-MAR-20:42 0.00 01-MAR-00:10 12659.91 05-MAR-22:52 12648.90 11-MAR-18:52 658.22 06-MAR-18:42 2799.35 17-MAR-11:22 0.00
April 0.470639E+10 0.125422E+10 568.82 0.470617E+10 219630.53 0.00 1.00 01-APR-09:42 0.00 01-APR-06:50 12533.83 16-APR-12:22 12533.83 16-APR-12:22 18.92 17-APR-03:20 2801.43 16-APR-13:42 0.00
May 0.634037E+10 0.172429E+10 640.53 0.634037E+10 -0.0 0.00 1.00 01-MAY-10:42 0.00 01-MAY-07:02 12433.87 11-MAY-08:62 12433.87 11-MAY-08:62 0.00 20-MAY-08:62 2797.51 18-MAY-08:12 0.00
June 0.848760E+10 0.240465E+10 677.83 0.847683E+10 10763198.44 0.00 1.00 01-JUN-07:22 0.00 01-JUN-05:15 12536.27 04-JUN-06:42 12536.27 04-JUN-06:42 335.13 17-JUN-18:30 2834.62 23-JUN-07:02 0.00
July 0.865876E+10 0.237655E+10 720.28 0.801895E+10 0.639814E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 13644.44 15-JUL-06:42 12306.45 06-JUL-07:12 4303.07 15-JUL-06:43 2893.27 29-JUL-08:12 0.00
August 0.799320E+10 0.218921E+10 692.78 0.737933E+10 0.613864E+09 0.00 1.00 03-AUG-19:12 0.00 03-AUG-17:42 13680.20 04-AUG-09:12 12352.17 23-AUG-08:12 4407.68 04-AUG-09:13 2891.77 10-AUG-07:12 0.00
September 0.673827E+10 0.179919E+10 629.37 0.616818E+10 0.570085E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-05:13 14072.82 03-SEP-11:22 12595.61 20-SEP-07:52 5983.72 03-SEP-11:23 2919.97 12-SEP-07:52 0.00
October 0.320386E+10 0.847230E+09 473.21 0.310277E+10 0.101089E+09 0.00 1.00 01-OCT-07:42 0.00 01-OCT-05:13 13497.44 03-OCT-08:62 12683.99 21-OCT-20:02 3826.01 03-OCT-08:03 2887.57 03-OCT-08:62 0.00
November 0.995074E+09 0.251637E+09 246.77 0.937609E+09 57464972.07 0.00 1.00 01-NOV-11:12 0.00 01-NOV-05:13 13756.38 12-NOV-22:52 12672.39 01-NOV-19:52 5023.11 12-NOV-22:52 2809.91 01-NOV-11:12 0.00
December 0.168450E+09 43161911.65 68.97 0.168449E+09 682.74 0.00 1.00 02-DEC-13:42 0.00 01-DEC-00:10 12169.28 26-DEC-21:32 12169.28 26-DEC-21:32 1.14 13-DEC-13:30 2689.86 26-DEC-21:32 0.00
                                       
Annual Sum or Average 0.492695E+11 0.133947E+11 5350.80 0.472520E+11 0.201747E+10 0.00                         0.00
Minimum of Months 0.168450E+09 43161911.65 68.97 0.168449E+09 -0.0 0.00 1.00   0.00   12169.28   12169.28   0.00   2689.86   0.00
Maximum of Months 0.865876E+10 0.240465E+10 720.28 0.847683E+10 0.639814E+09 0.00 1.00   0.00   14072.82   12683.99   5983.72   2919.97   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT MSE HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.300877E+10 0.748274E+09 534.95 0.299566E+10 13111596.98 0.00 1.00 02-JAN-13:12 0.00 01-JAN-00:10 12477.51 08-JAN-20:12 11822.57 08-JAN-11:52 2914.10 08-JAN-20:13 2598.32 31-JAN-17:01 0.00
February 0.152261E+10 0.379076E+09 408.29 0.147273E+10 49885108.66 0.00 1.00 01-FEB-17:01 0.00 01-FEB-09:05 12178.25 18-FEB-19:12 11827.11 14-FEB-17:01 1588.64 18-FEB-19:12 2578.51 18-FEB-19:12 0.00
March 0.203338E+10 0.507418E+09 400.30 0.202042E+10 12957451.05 0.00 1.00 01-MAR-17:02 0.00 01-MAR-09:05 11868.06 05-MAR-22:52 11838.64 11-MAR-18:52 700.36 06-MAR-18:42 2658.00 20-MAR-16:01 0.00
April 0.549194E+10 0.143237E+10 589.18 0.549163E+10 310744.48 0.00 1.00 01-APR-09:42 0.00 01-APR-07:00 11734.01 16-APR-12:32 11734.01 16-APR-12:32 24.18 17-APR-03:10 2738.12 25-APR-16:01 0.00
May 0.612587E+10 0.163658E+10 635.18 0.612587E+10 -0.0 0.00 1.00 01-MAY-16:01 0.00 01-MAY-07:02 11634.02 11-MAY-07:32 11634.02 11-MAY-07:32 0.00 10-MAY-16:08 2750.32 10-MAY-16:01 0.00
June 0.787163E+10 0.219353E+10 665.21 0.786097E+10 10654777.87 0.00 1.00 01-JUN-06:52 0.00 01-JUN-05:15 11680.68 04-JUN-06:42 11680.68 04-JUN-06:42 411.82 17-JUN-17:10 2906.19 30-JUN-16:01 0.00
July 0.852174E+10 0.229450E+10 703.15 0.789954E+10 0.622194E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 12668.44 15-JUL-06:42 11537.83 06-JUL-06:52 3742.32 15-JUL-06:43 2994.85 18-JUL-16:01 0.00
August 0.825606E+10 0.220649E+10 683.64 0.766191E+10 0.594150E+09 0.00 1.00 01-AUG-16:01 0.00 01-AUG-08:62 12717.10 05-AUG-20:52 11715.36 23-AUG-07:22 3871.68 05-AUG-20:53 2965.07 11-AUG-16:01 0.00
September 0.753640E+10 0.196734E+10 632.56 0.696873E+10 0.567667E+09 0.00 1.00 01-SEP-06:52 0.00 01-SEP-05:13 13169.82 03-SEP-10:42 11746.07 20-SEP-07:52 5754.86 03-SEP-10:43 2935.68 06-SEP-16:01 0.00
October 0.501703E+10 0.128270E+10 574.58 0.490882E+10 0.108206E+09 0.00 1.00 01-OCT-07:32 0.00 01-OCT-05:13 12540.24 03-OCT-07:22 11831.44 21-OCT-20:42 3209.75 03-OCT-07:23 2901.87 03-OCT-16:01 0.00
November 0.293145E+10 0.727325E+09 504.44 0.285335E+10 78098164.55 0.00 1.00 01-NOV-16:01 0.00 01-NOV-05:13 12825.95 12-NOV-22:52 11835.50 02-NOV-19:02 4671.83 12-NOV-22:52 2673.53 01-NOV-16:01 0.00
December 0.194694E+10 0.487407E+09 402.13 0.194683E+10 105849.74 0.00 1.00 01-DEC-17:01 0.00 01-DEC-09:05 11625.58 13-DEC-17:01 11625.58 13-DEC-17:01 59.14 13-DEC-09:00 2536.38 13-DEC-17:01 0.00
                                       
Annual Sum or Average 0.602638E+11 0.158630E+11 6733.60 0.582065E+11 0.205734E+10 0.00                         0.00
Minimum of Months 0.152261E+10 0.379076E+09 400.30 0.147273E+10 -0.0 0.00 1.00   0.00   11625.58   11537.83   0.00   2536.38   0.00
Maximum of Months 0.852174E+10 0.229450E+10 703.15 0.789954E+10 0.622194E+09 0.00 1.00   0.00   13169.82   11838.64   5754.86   2994.85   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT MNE HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.586762E+09 0.150251E+09 200.95 0.580523E+09 6239503.89 0.00 1.00 07-JAN-22:52 0.00 01-JAN-00:10 12280.75 08-JAN-20:12 11388.13 07-JAN-22:52 3114.27 08-JAN-20:12 2551.61 08-JAN-20:12 0.00
February 0.301896E+09 76106530.54 204.13 0.282814E+09 19081934.25 0.00 1.00 16-FEB-20:12 0.00 01-FEB-02:00 11901.12 18-FEB-19:12 11414.98 22-FEB-20:32 1503.48 18-FEB-19:12 2534.79 18-FEB-19:12 0.00
March 0.113729E+10 0.290103E+09 299.36 0.112942E+10 7872350.61 0.00 1.00 01-MAR-20:42 0.00 01-MAR-00:10 11637.04 05-MAR-22:52 11576.48 18-MAR-11:32 556.34 06-MAR-18:42 2570.80 17-MAR-11:22 0.00
April 0.471693E+10 0.125234E+10 573.66 0.471670E+10 227367.39 0.00 1.00 01-APR-09:42 0.00 01-APR-07:00 11516.04 16-APR-12:22 11516.04 16-APR-12:22 19.44 17-APR-03:20 2572.09 16-APR-13:42 0.00
May 0.642284E+10 0.173714E+10 648.01 0.642284E+10 -0.0 0.00 1.00 01-MAY-10:42 0.00 01-MAY-07:02 11430.85 11-MAY-08:62 11430.85 11-MAY-08:62 0.00 24-MAY-08:42 2568.80 18-MAY-08:12 0.00
June 0.859056E+10 0.241763E+10 678.75 0.857940E+10 11154142.07 0.00 1.00 01-JUN-07:22 0.00 01-JUN-05:15 11501.95 04-JUN-06:42 11501.95 04-JUN-06:42 327.82 17-JUN-17:10 2600.67 23-JUN-07:02 0.00
July 0.894486E+10 0.243855E+10 721.94 0.829125E+10 0.653614E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 12531.87 15-JUL-06:42 11293.80 06-JUL-07:12 3897.74 15-JUL-06:43 2654.17 29-JUL-08:12 0.00
August 0.825334E+10 0.224491E+10 696.43 0.762277E+10 0.630571E+09 0.00 1.00 03-AUG-19:12 0.00 03-AUG-17:42 12545.60 04-AUG-09:12 11348.85 23-AUG-08:12 3981.44 05-AUG-21:53 2653.79 10-AUG-07:12 0.00
September 0.686847E+10 0.182337E+10 634.17 0.628475E+10 0.583715E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-05:13 12912.22 03-SEP-11:22 11565.98 20-SEP-07:52 5462.60 03-SEP-11:23 2679.12 12-SEP-07:52 0.00
October 0.327606E+10 0.862744E+09 483.64 0.316978E+10 0.106279E+09 0.00 1.00 01-OCT-07:42 0.00 01-OCT-05:13 12388.23 03-OCT-08:62 11635.64 21-OCT-20:02 3506.49 03-OCT-08:03 2649.21 03-OCT-08:62 0.00
November 0.903581E+09 0.228545E+09 249.22 0.850791E+09 52789934.52 0.00 1.00 01-NOV-11:12 0.00 01-NOV-05:13 12609.06 12-NOV-22:52 11607.01 01-NOV-19:52 4653.70 12-NOV-22:52 2578.39 01-NOV-11:12 0.00
December 0.155636E+09 39934609.18 81.67 0.155585E+09 51506.60 0.00 1.00 01-DEC-19:12 0.00 01-DEC-00:10 11130.43 27-DEC-19:02 11130.43 27-DEC-19:02 9.40 13-DEC-12:00 2491.98 25-DEC-13:12 0.00
                                       
Annual Sum or Average 0.501582E+11 0.135616E+11 5471.93 0.480866E+11 0.207160E+10 0.00                         0.00
Minimum of Months 0.155636E+09 39934609.18 81.67 0.155585E+09 -0.0 0.00 1.00   0.00   11130.43   11130.43   0.00   2491.98   0.00
Maximum of Months 0.894486E+10 0.243855E+10 721.94 0.857940E+10 0.653614E+09 0.00 1.00   0.00   12912.22   11635.64   5462.60   2679.12   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT MN1 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.846795E+09 0.216254E+09 346.67 0.837594E+09 9201490.10 0.00 1.00 05-JAN-20:02 0.00 01-JAN-00:10 10548.17 08-JAN-20:12 9793.21 21-JAN-19:12 2634.01 08-JAN-20:13 2188.25 08-JAN-20:12 0.00
February 0.602808E+09 0.151871E+09 351.48 0.561884E+09 40923430.35 0.00 1.00 15-FEB-21:12 0.00 01-FEB-04:40 10204.86 18-FEB-19:12 9807.31 22-FEB-20:32 1230.23 18-FEB-19:12 2173.39 18-FEB-19:12 0.00
March 0.125582E+10 0.319496E+09 383.44 0.124409E+10 11725036.54 0.00 1.00 01-MAR-20:42 0.00 01-MAR-03:20 10035.16 06-MAR-18:42 9908.26 11-MAR-18:52 741.15 06-MAR-18:42 2201.86 17-MAR-11:22 0.00
April 0.373669E+10 0.993833E+09 566.43 0.373646E+10 223471.10 0.00 1.00 01-APR-09:42 0.00 01-APR-07:00 9844.15 16-APR-12:22 9844.15 16-APR-12:22 19.13 17-APR-03:30 2203.09 16-APR-13:42 0.00
May 0.498633E+10 0.135304E+10 640.17 0.498633E+10 -0.0 0.00 1.00 01-MAY-10:42 0.00 01-MAY-07:02 9770.47 11-MAY-08:62 9770.47 11-MAY-08:62 0.00 13-MAY-10:32 2199.70 18-MAY-08:12 0.00
June 0.651918E+10 0.184503E+10 673.61 0.650920E+10 9973190.04 0.00 1.00 01-JUN-07:22 0.00 01-JUN-05:15 9851.29 04-JUN-06:42 9851.29 04-JUN-06:42 275.34 17-JUN-18:40 2230.58 23-JUN-07:02 0.00
July 0.698941E+10 0.190892E+10 719.87 0.640539E+10 0.584022E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 10728.65 15-JUL-06:42 9666.71 06-JUL-07:12 3392.74 15-JUL-06:43 2275.57 29-JUL-08:12 0.00
August 0.648185E+10 0.176392E+10 692.96 0.591531E+10 0.566538E+09 0.00 1.00 03-AUG-19:12 0.00 03-AUG-17:42 10750.08 04-AUG-09:12 9708.44 23-AUG-08:12 3440.58 04-AUG-09:13 2274.34 10-AUG-07:12 0.00
September 0.561012E+10 0.148760E+10 628.56 0.508272E+10 0.527400E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-05:13 11064.58 03-SEP-11:22 9899.42 20-SEP-07:52 4689.76 03-SEP-11:23 2296.17 12-SEP-07:52 0.00
October 0.286629E+10 0.752577E+09 501.99 0.276881E+10 97487385.59 0.00 1.00 01-OCT-07:42 0.00 01-OCT-05:13 10611.94 03-OCT-08:62 9975.16 21-OCT-20:02 3104.12 03-OCT-08:03 2271.06 03-OCT-08:62 0.00
November 0.114005E+10 0.287524E+09 357.82 0.107395E+10 66099118.33 0.00 1.00 01-NOV-11:12 0.00 01-NOV-05:13 10841.20 12-NOV-22:52 9951.02 01-NOV-19:52 3964.24 12-NOV-22:53 2209.94 01-NOV-11:12 0.00
December 0.331959E+09 85192372.47 200.93 0.331684E+09 274812.49 0.00 1.00 01-DEC-19:12 0.00 01-DEC-03:40 9599.59 03-DEC-19:12 9599.59 03-DEC-19:12 27.78 13-DEC-11:40 2136.47 25-DEC-13:12 0.00
                                       
Annual Sum or Average 0.413673E+11 0.111653E+11 6063.94 0.394534E+11 0.191387E+10 0.00                         0.00
Minimum of Months 0.331959E+09 85192372.47 200.93 0.331684E+09 -0.0 0.00 1.00   0.00   9599.59   9599.59   0.00   2136.47   0.00
Maximum of Months 0.698941E+10 0.190892E+10 719.87 0.650920E+10 0.584022E+09 0.00 1.00   0.00   11064.58   9975.16   4689.76   2296.17   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT MN2 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.843369E+09 0.215386E+09 344.81 0.834232E+09 9136725.00 0.00 1.00 05-JAN-20:02 0.00 01-JAN-00:10 10528.62 08-JAN-20:12 9775.26 21-JAN-19:12 2594.44 08-JAN-20:13 2184.36 08-JAN-20:12 0.00
February 0.612864E+09 0.154395E+09 353.51 0.571340E+09 41523787.37 0.00 1.00 15-FEB-21:12 0.00 01-FEB-04:40 10187.88 18-FEB-19:12 9789.10 22-FEB-20:32 1223.88 18-FEB-19:12 2169.61 18-FEB-19:12 0.00
March 0.126402E+10 0.321534E+09 383.77 0.125212E+10 11894847.81 0.00 1.00 01-MAR-20:42 0.00 01-MAR-03:20 10017.55 06-MAR-18:42 9887.14 11-MAR-18:52 738.44 06-MAR-18:42 2198.04 17-MAR-11:22 0.00
April 0.375116E+10 0.997482E+09 566.37 0.375093E+10 229641.47 0.00 1.00 01-APR-09:42 0.00 01-APR-07:00 9829.87 16-APR-12:22 9829.87 16-APR-12:22 19.50 17-APR-03:30 2199.52 16-APR-13:42 0.00
May 0.500028E+10 0.135656E+10 640.13 0.500028E+10 -0.0 0.00 1.00 01-MAY-10:42 0.00 01-MAY-07:02 9754.43 11-MAY-08:62 9754.43 11-MAY-08:62 0.00 29-MAY-09:03 2196.10 18-MAY-08:12 0.00
June 0.652615E+10 0.184678E+10 673.81 0.651616E+10 9984026.75 0.00 1.00 01-JUN-07:22 0.00 01-JUN-05:15 9834.10 04-JUN-06:42 9834.10 04-JUN-06:42 275.26 17-JUN-18:40 2226.64 23-JUN-07:02 0.00
July 0.700082E+10 0.191177E+10 719.96 0.641634E+10 0.584482E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 10710.00 15-JUL-06:42 9649.51 06-JUL-07:12 3386.95 15-JUL-06:43 2271.60 29-JUL-08:12 0.00
August 0.649369E+10 0.176687E+10 693.01 0.592653E+10 0.567157E+09 0.00 1.00 03-AUG-19:12 0.00 03-AUG-17:42 10731.23 04-AUG-09:12 9692.06 23-AUG-08:12 3432.97 04-AUG-09:13 2270.32 10-AUG-07:12 0.00
September 0.561876E+10 0.148968E+10 628.59 0.509085E+10 0.527914E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-05:13 11045.11 03-SEP-11:22 9882.05 20-SEP-07:52 4680.67 03-SEP-11:23 2292.12 12-SEP-07:52 0.00
October 0.287671E+10 0.755207E+09 502.19 0.277905E+10 97655852.80 0.00 1.00 01-OCT-07:42 0.00 01-OCT-05:13 10593.46 03-OCT-08:62 9957.77 21-OCT-20:02 3095.74 03-OCT-08:03 2267.06 03-OCT-08:62 0.00
November 0.113574E+10 0.286476E+09 357.32 0.107019E+10 65549306.58 0.00 1.00 01-NOV-11:12 0.00 01-NOV-05:13 10821.02 12-NOV-22:52 9932.67 01-NOV-19:52 3961.24 12-NOV-22:53 2206.11 01-NOV-11:12 0.00
December 0.334148E+09 85753981.95 202.28 0.333863E+09 284680.68 0.00 1.00 01-DEC-19:12 0.00 01-DEC-03:40 9583.30 03-DEC-19:12 9583.30 03-DEC-19:12 28.71 13-DEC-11:30 2132.91 25-DEC-13:12 0.00
                                       
Annual Sum or Average 0.414577E+11 0.111879E+11 6065.76 0.395419E+11 0.191581E+10 0.00                         0.00
Minimum of Months 0.334148E+09 85753981.95 202.28 0.333863E+09 -0.0 0.00 1.00   0.00   9583.30   9583.30   0.00   2132.91   0.00
Maximum of Months 0.700082E+10 0.191177E+10 719.96 0.651616E+10 0.584482E+09 0.00 1.00   0.00   11045.11   9957.77   4680.67   2292.12   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT MS1 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.354885E+10 0.879326E+09 549.07 0.353291E+10 15942421.54 0.00 1.00 02-JAN-13:12 0.00 01-JAN-00:30 10702.27 08-JAN-20:12 10158.32 08-JAN-13:22 2398.07 08-JAN-20:13 2232.93 31-JAN-17:01 0.00
February 0.208045E+10 0.516702E+09 485.65 0.200694E+10 73509035.39 0.00 1.00 01-FEB-17:01 0.00 01-FEB-09:05 10456.54 18-FEB-19:12 10165.58 14-FEB-17:01 1462.41 18-FEB-19:13 2214.85 18-FEB-19:12 0.00
March 0.226842E+10 0.564477E+09 441.30 0.225170E+10 16727271.01 0.00 1.00 01-MAR-17:02 0.00 01-MAR-09:05 10220.82 06-MAR-18:42 10175.04 18-MAR-10:12 552.38 06-MAR-18:42 2283.47 20-MAR-16:01 0.00
April 0.457557E+10 0.118907E+10 556.59 0.457520E+10 364489.89 0.00 1.00 01-APR-09:42 0.00 01-APR-07:00 10070.87 16-APR-11:12 10070.87 16-APR-11:12 26.72 17-APR-03:10 2352.66 25-APR-16:01 0.00
May 0.481896E+10 0.128240E+10 572.91 0.481896E+10 -0.0 0.00 1.00 01-MAY-16:01 0.00 01-MAY-07:02 9984.95 11-MAY-07:32 9984.95 11-MAY-07:32 0.00 12-MAY-16:01 2363.22 10-MAY-16:01 0.00
June 0.593640E+10 0.165101E+10 615.44 0.592661E+10 9784163.68 0.00 1.00 01-JUN-06:52 0.00 01-JUN-05:15 10019.20 04-JUN-06:42 10019.20 04-JUN-06:42 342.40 17-JUN-17:10 2496.67 30-JUN-16:01 0.00
July 0.669057E+10 0.179456E+10 656.07 0.613473E+10 0.555847E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 10886.91 15-JUL-06:42 9909.27 06-JUL-06:52 3239.99 15-JUL-06:43 2589.35 18-JUL-16:01 0.00
August 0.661619E+10 0.175737E+10 644.28 0.607946E+10 0.536729E+09 0.00 1.00 01-AUG-16:01 0.00 01-AUG-08:62 10920.44 05-AUG-20:52 10059.96 23-AUG-07:22 3284.81 05-AUG-20:53 2560.37 01-AUG-16:01 0.00
September 0.637584E+10 0.165492E+10 606.97 0.585761E+10 0.518224E+09 0.00 1.00 01-SEP-06:52 0.00 01-SEP-05:13 11307.89 03-SEP-10:42 10093.33 20-SEP-07:52 5023.96 03-SEP-10:45 2526.93 06-SEP-16:01 0.00
October 0.470040E+10 0.119288E+10 560.47 0.459799E+10 0.102409E+09 0.00 1.00 01-OCT-07:32 0.00 01-OCT-05:13 10777.62 03-OCT-07:22 10166.02 21-OCT-20:42 2755.50 03-OCT-07:23 2501.37 03-OCT-16:01 0.00
November 0.338293E+10 0.835431E+09 519.83 0.329384E+10 89082685.99 0.00 1.00 01-NOV-16:01 0.00 01-NOV-05:13 11050.49 12-NOV-22:52 10171.07 18-NOV-13:52 3990.00 12-NOV-22:53 2297.31 01-NOV-16:01 0.00
December 0.270908E+10 0.677409E+09 526.29 0.270831E+10 765683.89 0.00 1.00 01-DEC-17:01 0.00 01-DEC-09:05 10015.72 13-DEC-17:01 10015.72 13-DEC-17:01 66.72 13-DEC-09:00 2181.67 13-DEC-17:01 0.00
                                       
Annual Sum or Average 0.537037E+11 0.139955E+11 6734.87 0.517843E+11 0.191939E+10 0.00                         0.00
Minimum of Months 0.208045E+10 0.516702E+09 441.30 0.200694E+10 -0.0 0.00 1.00   0.00   9984.95   9909.27   0.00   2181.67   0.00
Maximum of Months 0.669057E+10 0.179456E+10 656.07 0.613473E+10 0.555847E+09 0.00 1.00   0.00   11307.89   10175.04   5023.96   2589.35   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT MS2 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.355293E+10 0.880293E+09 549.40 0.353697E+10 15958318.05 0.00 1.00 02-JAN-13:12 0.00 01-JAN-00:30 10685.62 08-JAN-20:12 10143.63 08-JAN-13:22 2394.37 08-JAN-20:13 2229.44 31-JAN-17:01 0.00
February 0.209446E+10 0.520127E+09 486.52 0.202057E+10 73885885.67 0.00 1.00 01-FEB-17:01 0.00 01-FEB-09:05 10441.16 18-FEB-19:12 10151.23 14-FEB-17:01 1456.43 18-FEB-19:13 2211.43 18-FEB-19:12 0.00
March 0.228316E+10 0.568085E+09 442.70 0.226606E+10 17098359.27 0.00 1.00 01-MAR-17:02 0.00 01-MAR-09:05 10205.22 06-MAR-18:42 10160.15 18-MAR-10:12 549.44 06-MAR-18:42 2279.89 20-MAR-16:01 0.00
April 0.459436E+10 0.119383E+10 559.35 0.459400E+10 365614.72 0.00 1.00 01-APR-09:42 0.00 01-APR-07:00 10055.19 16-APR-11:12 10055.19 16-APR-11:12 26.80 17-APR-03:10 2349.00 25-APR-16:01 0.00
May 0.483823E+10 0.128743E+10 576.22 0.483823E+10 -0.0 0.00 1.00 01-MAY-16:01 0.00 01-MAY-07:02 9969.92 11-MAY-07:32 9969.92 11-MAY-07:32 0.00 03-MAY-16:02 2359.59 10-MAY-16:01 0.00
June 0.594992E+10 0.165473E+10 617.03 0.594013E+10 9793724.22 0.00 1.00 01-JUN-06:52 0.00 01-JUN-05:15 10003.79 04-JUN-06:42 10003.79 04-JUN-06:42 342.73 17-JUN-17:10 2492.78 30-JUN-16:01 0.00
July 0.670735E+10 0.179889E+10 657.04 0.615084E+10 0.556510E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 10869.91 15-JUL-06:42 9893.88 06-JUL-06:52 3232.75 15-JUL-06:43 2584.92 18-JUL-16:01 0.00
August 0.663355E+10 0.176183E+10 645.78 0.609614E+10 0.537411E+09 0.00 1.00 01-AUG-16:01 0.00 01-AUG-08:62 10903.13 05-AUG-20:52 10044.21 23-AUG-07:22 3278.59 05-AUG-20:53 2555.96 01-AUG-16:01 0.00
September 0.638724E+10 0.165774E+10 608.16 0.586853E+10 0.518710E+09 0.00 1.00 01-SEP-06:52 0.00 01-SEP-05:13 11290.29 03-SEP-10:42 10077.51 20-SEP-07:52 5015.23 03-SEP-10:45 2522.85 06-SEP-16:01 0.00
October 0.471524E+10 0.119654E+10 561.81 0.461267E+10 0.102568E+09 0.00 1.00 01-OCT-07:32 0.00 01-OCT-05:13 10760.31 03-OCT-07:22 10150.11 21-OCT-20:42 2749.13 03-OCT-07:23 2497.23 03-OCT-16:01 0.00
November 0.338362E+10 0.835606E+09 520.56 0.329481E+10 88802359.24 0.00 1.00 01-NOV-16:01 0.00 01-NOV-05:13 11032.98 13-NOV-17:01 10156.07 18-NOV-13:52 3985.69 12-NOV-22:53 2293.71 01-NOV-16:01 0.00
December 0.271847E+10 0.679725E+09 527.64 0.271771E+10 760702.47 0.00 1.00 01-DEC-17:01 0.00 01-DEC-09:05 9999.63 13-DEC-17:01 9999.63 13-DEC-17:01 66.95 13-DEC-09:00 2178.21 13-DEC-17:01 0.00
                                       
Annual Sum or Average 0.538585E+11 0.140348E+11 6752.20 0.519367E+11 0.192186E+10 0.00                         0.00
Minimum of Months 0.209446E+10 0.520127E+09 442.70 0.202057E+10 -0.0 0.00 1.00   0.00   9969.92   9893.88   0.00   2178.21   0.00
Maximum of Months 0.670735E+10 0.179889E+10 657.04 0.615084E+10 0.556510E+09 0.00 1.00   0.00   11290.29   10160.15   5015.23   2584.92   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT TSW HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.963442E+09 0.238003E+09 242.06 0.961751E+09 1690955.55 0.00 1.00 02-JAN-13:12 0.00 01-JAN-00:10 7823.16 08-JAN-20:12 7490.67 22-JAN-15:52 1991.87 08-JAN-20:12 1634.38 31-JAN-17:01 0.00
February 0.284162E+09 70089961.25 119.78 0.282402E+09 1759769.71 0.00 1.00 01-FEB-17:01 0.00 01-FEB-00:40 7630.13 18-FEB-19:12 7457.10 13-FEB-17:01 1129.99 18-FEB-19:12 1620.89 18-FEB-19:12 0.00
March 0.633698E+09 0.157733E+09 179.18 0.632818E+09 879325.75 0.00 1.00 02-MAR-17:01 0.00 01-MAR-00:10 7425.98 18-MAR-10:12 7425.98 18-MAR-10:12 195.58 05-MAR-22:52 1672.52 20-MAR-16:01 0.00
April 0.276292E+10 0.730818E+09 507.70 0.276290E+10 16001.67 0.00 1.00 01-APR-09:42 0.00 01-APR-00:40 7417.57 16-APR-13:22 7417.57 16-APR-13:22 2.65 17-APR-02:00 1723.35 25-APR-16:01 0.00
May 0.328171E+10 0.891925E+09 596.88 0.328171E+10 -0.0 0.00 1.00 01-MAY-16:01 0.00 01-MAY-02:40 7252.14 11-MAY-07:32 7252.14 11-MAY-07:32 0.00 03-MAY-16:02 1730.79 10-MAY-16:01 0.00
June 0.451607E+10 0.128076E+10 655.03 0.451085E+10 5218214.50 0.00 1.00 01-JUN-06:52 0.00 01-JUN-05:15 7334.68 04-JUN-06:42 7334.68 04-JUN-06:42 235.04 17-JUN-17:10 1829.51 30-JUN-16:01 0.00
July 0.471122E+10 0.129262E+10 701.17 0.440076E+10 0.310458E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 8048.10 15-JUL-06:42 7239.58 06-JUL-06:52 2585.03 15-JUL-06:42 1876.45 18-JUL-16:01 0.00
August 0.449993E+10 0.122869E+10 675.76 0.421116E+10 0.288769E+09 0.00 1.00 01-AUG-16:01 0.00 01-AUG-08:62 8000.45 05-AUG-09:12 7295.77 23-AUG-07:22 2544.48 04-AUG-07:32 1862.32 11-AUG-16:01 0.00
September 0.399719E+10 0.106429E+10 623.78 0.372084E+10 0.276348E+09 0.00 1.00 01-SEP-06:52 0.00 01-SEP-05:13 8285.66 03-SEP-10:42 7390.81 20-SEP-07:52 3626.59 03-SEP-10:43 1844.91 06-SEP-16:01 0.00
October 0.223401E+10 0.580720E+09 426.26 0.218754E+10 46466630.39 0.00 1.00 01-OCT-07:32 0.00 01-OCT-05:13 7941.78 03-OCT-07:22 7613.04 07-OCT-15:52 2297.77 03-OCT-07:22 1819.91 03-OCT-16:01 0.00
November 0.932336E+09 0.230444E+09 262.10 0.914684E+09 17651123.16 0.00 1.00 01-NOV-16:01 0.00 01-NOV-05:13 8047.56 13-NOV-22:52 7453.88 02-NOV-19:02 2887.10 13-NOV-22:52 1682.90 01-NOV-16:01 0.00
December 0.485611E+09 0.120134E+09 151.08 0.485611E+09 -0.0 0.00 1.00 01-DEC-17:01 0.00 01-DEC-00:10 7334.60 13-DEC-17:01 7334.60 13-DEC-17:01 0.00 23-DEC-16:12 1597.97 13-DEC-17:01 0.00
                                       
Annual Sum or Average 0.293023E+11 0.788622E+10 5140.78 0.283530E+11 0.949258E+09 0.00                         0.00
Minimum of Months 0.284162E+09 70089961.25 119.78 0.282402E+09 -0.0 0.00 1.00   0.00   7252.14   7239.58   0.00   1597.97   0.00
Maximum of Months 0.471122E+10 0.129262E+10 701.17 0.451085E+10 0.310458E+09 0.00 1.00   0.00   8285.66   7613.04   3626.59   1876.45   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT TNW HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.136376E+09 35549690.76 52.11 0.136114E+09 262660.50 0.00 0.90 18-JAN-14:42 0.00 01-JAN-00:10 6250.73 26-JAN-14:42 6250.73 26-JAN-14:42 989.71 08-JAN-20:12 1412.92 18-JAN-14:42 0.00
February 7560207.70 1906002.64 6.85 7497812.87 62394.83 0.00 0.84 22-FEB-20:32 0.00 01-FEB-00:10 5960.92 22-FEB-20:32 5960.92 22-FEB-20:32 261.35 18-FEB-19:12 1340.01 22-FEB-20:32 0.00
March 0.343289E+09 88163665.27 100.80 0.343080E+09 209428.80 0.00 1.00 09-MAR-18:32 0.00 01-MAR-00:10 7392.27 11-MAR-18:52 7356.04 11-MAR-18:52 82.31 05-MAR-22:52 1635.01 17-MAR-11:22 0.00
April 0.237952E+10 0.638914E+09 481.38 0.237951E+10 9799.27 0.00 1.00 03-APR-09:42 0.00 01-APR-00:10 7324.34 16-APR-12:22 7324.34 16-APR-12:22 1.81 17-APR-02:00 1637.52 16-APR-13:42 0.00
May 0.341796E+10 0.936272E+09 616.49 0.341796E+10 -0.0 0.00 1.00 01-MAY-10:42 0.00 01-MAY-02:20 7252.37 11-MAY-08:62 7252.37 11-MAY-08:62 0.00 12-MAY-08:42 1634.05 18-MAY-08:12 0.00
June 0.489424E+10 0.139408E+10 676.78 0.488862E+10 5617781.56 0.00 1.00 01-JUN-07:22 0.00 01-JUN-05:15 7328.90 04-JUN-06:42 7328.90 04-JUN-06:42 194.40 17-JUN-17:10 1656.39 23-JUN-07:02 0.00
July 0.494963E+10 0.136712E+10 720.03 0.461757E+10 0.332061E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 8035.58 15-JUL-06:42 7184.85 06-JUL-07:12 2641.54 15-JUL-06:43 1693.34 29-JUL-08:12 0.00
August 0.450120E+10 0.124274E+10 693.11 0.418901E+10 0.312186E+09 0.00 1.00 03-AUG-19:12 0.00 03-AUG-17:42 8015.79 04-AUG-09:12 7219.13 23-AUG-08:12 2519.72 04-AUG-09:13 1692.79 10-AUG-07:12 0.00
September 0.366265E+10 0.986722E+09 630.34 0.337664E+10 0.286010E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-05:13 8232.01 03-SEP-11:22 7368.91 20-SEP-07:52 3473.13 03-SEP-11:23 1709.06 12-SEP-07:52 0.00
October 0.144161E+10 0.386522E+09 325.91 0.139505E+10 46561128.42 0.00 1.00 01-OCT-07:42 0.00 01-OCT-05:13 7923.24 03-OCT-08:62 7417.59 21-OCT-20:02 2330.03 03-OCT-08:62 1689.51 03-OCT-08:62 0.00
November 0.244062E+09 62585825.81 84.96 0.235889E+09 8173075.46 0.00 1.00 01-NOV-11:12 0.00 01-NOV-00:10 7937.51 11-NOV-22:52 7408.00 01-NOV-19:52 2323.79 11-NOV-22:52 1643.68 01-NOV-11:12 0.00
December 24640577.03 6457248.85 12.86 24640577.03 -0.0 0.00 0.38 24-DEC-14:43 0.00 01-DEC-00:10 2386.93 24-DEC-14:43 2386.93 24-DEC-14:43 0.00 26-DEC-21:32 590.43 24-DEC-14:43 0.00
                                       
Annual Sum or Average 0.260027E+11 0.714703E+10 4401.62 0.250116E+11 0.991153E+09 0.00                         0.00
Minimum of Months 7560207.70 1906002.64 6.85 7497812.87 -0.0 0.00 0.38   0.00   2386.93   2386.93   0.00   590.43   0.00
Maximum of Months 0.494963E+10 0.139408E+10 720.03 0.488862E+10 0.332061E+09 0.00 1.00   0.00   8232.01   7417.59   3473.13   1709.06   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT TSE HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.901369E+09 0.222554E+09 255.70 0.899545E+09 1823940.09 0.00 1.00 02-JAN-13:12 0.00 01-JAN-00:10 7017.24 08-JAN-20:12 6696.06 22-JAN-15:52 1834.71 08-JAN-20:12 1464.47 31-JAN-17:01 0.00
February 0.279830E+09 69015144.46 137.90 0.276641E+09 3188900.85 0.00 1.00 01-FEB-17:01 0.00 01-FEB-00:30 6858.18 18-FEB-19:12 6685.21 13-FEB-17:01 998.67 18-FEB-19:12 1453.50 18-FEB-19:12 0.00
March 0.612670E+09 0.152448E+09 190.45 0.611593E+09 1077424.73 0.00 1.00 02-MAR-17:01 0.00 01-MAR-00:10 6757.94 18-MAR-11:02 6757.94 18-MAR-11:02 228.03 05-MAR-22:52 1498.61 20-MAR-16:01 0.00
April 0.273230E+10 0.721087E+09 523.86 0.273228E+10 15370.84 0.00 1.00 01-APR-09:42 0.00 01-APR-00:20 6743.71 16-APR-10:52 6743.71 16-APR-10:52 2.57 17-APR-02:00 1544.11 25-APR-16:01 0.00
May 0.327680E+10 0.888571E+09 621.48 0.327680E+10 0.00 0.00 1.00 01-MAY-10:22 0.00 01-MAY-02:30 6541.50 11-MAY-07:32 6541.50 11-MAY-07:32 0.00 26-MAY-16:12 1550.91 10-MAY-16:01 0.00
June 0.453906E+10 0.128220E+10 670.04 0.453368E+10 5380749.95 0.00 1.00 01-JUN-06:52 0.00 01-JUN-05:15 6587.29 04-JUN-06:42 6587.29 04-JUN-06:42 234.40 17-JUN-17:10 1639.00 30-JUN-16:01 0.00
July 0.484119E+10 0.132049E+10 711.62 0.452262E+10 0.318574E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 7208.20 15-JUL-06:42 6493.86 06-JUL-06:52 2385.69 15-JUL-06:43 1680.60 18-JUL-16:01 0.00
August 0.461138E+10 0.125217E+10 686.76 0.431451E+10 0.296862E+09 0.00 1.00 01-AUG-16:01 0.00 01-AUG-08:62 7155.87 04-AUG-07:32 6581.42 23-AUG-07:22 2278.11 04-AUG-07:32 1668.90 11-AUG-16:01 0.00
September 0.404975E+10 0.107215E+10 636.09 0.376602E+10 0.283735E+09 0.00 1.00 01-SEP-06:52 0.00 01-SEP-05:13 7422.76 03-SEP-10:42 6625.79 20-SEP-07:52 3237.81 03-SEP-10:43 1652.82 06-SEP-16:01 0.00
October 0.224284E+10 0.581264E+09 445.38 0.219472E+10 48117218.03 0.00 1.00 01-OCT-07:32 0.00 01-OCT-05:13 7125.43 03-OCT-07:22 6801.67 07-OCT-15:52 1981.04 03-OCT-07:22 1630.31 03-OCT-16:01 0.00
November 0.876182E+09 0.216923E+09 271.77 0.861718E+09 14464039.33 0.00 1.00 01-NOV-16:01 0.00 01-NOV-05:13 7205.71 13-NOV-17:01 6707.89 18-NOV-13:52 2559.10 13-NOV-17:01 1507.57 01-NOV-16:01 0.00
December 0.449275E+09 0.110903E+09 155.45 0.449275E+09 0.00 0.00 1.00 01-DEC-17:01 0.00 01-DEC-00:10 6568.88 13-DEC-17:01 6568.88 13-DEC-17:01 0.00 03-DEC-17:12 1431.49 13-DEC-17:01 0.00
                                       
Annual Sum or Average 0.294126E+11 0.788978E+10 5306.52 0.284394E+11 0.973238E+09 0.00                         0.00
Minimum of Months 0.279830E+09 69015144.46 137.90 0.276641E+09 0.00 0.00 1.00   0.00   6541.50   6493.86   0.00   1431.49   0.00
Maximum of Months 0.484119E+10 0.132049E+10 711.62 0.453368E+10 0.318574E+09 0.00 1.00   0.00   7422.76   6801.67   3237.81   1680.60   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT TNE HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.101827E+09 26565327.01 49.06 0.101648E+09 179047.38 0.00 1.00 18-JAN-14:42 0.00 01-JAN-00:10 6398.28 26-JAN-14:42 6398.28 26-JAN-14:42 772.80 08-JAN-20:12 1418.80 24-JAN-13:42 0.00
February 2723888.13 674973.66 4.40 2516460.60 207427.53 0.00 0.61 18-FEB-19:12 0.00 01-FEB-00:10 3850.46 18-FEB-19:12 3274.05 18-FEB-19:12 576.40 18-FEB-19:12 878.88 18-FEB-19:12 0.00
March 0.325511E+09 83556294.84 100.21 0.325309E+09 201333.27 0.00 1.00 09-MAR-18:32 0.00 01-MAR-00:10 6606.28 18-MAR-11:32 6606.28 18-MAR-11:32 150.41 05-MAR-22:52 1467.83 17-MAR-11:22 0.00
April 0.235929E+10 0.630685E+09 483.99 0.235928E+10 8799.48 0.00 1.00 01-APR-09:42 0.00 01-APR-00:10 6691.24 16-APR-12:02 6691.24 16-APR-12:02 1.71 17-APR-02:00 1467.99 16-APR-13:42 0.00
May 0.344466E+10 0.937120E+09 619.47 0.344466E+10 0.00 0.00 1.00 01-MAY-10:22 0.00 01-MAY-02:20 6579.90 13-MAY-10:12 6579.90 13-MAY-10:12 0.00 08-MAY-17:00 1465.72 18-MAY-08:12 0.00
June 0.494840E+10 0.139754E+10 679.11 0.494258E+10 5826593.20 0.00 1.00 01-JUN-07:22 0.00 01-JUN-05:15 6566.67 04-JUN-06:42 6566.67 04-JUN-06:42 193.96 17-JUN-17:10 1483.64 23-JUN-07:02 0.00
July 0.510202E+10 0.139720E+10 722.17 0.476225E+10 0.339772E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 7192.82 15-JUL-06:42 6443.96 06-JUL-07:12 2394.10 15-JUL-06:43 1516.10 29-JUL-08:12 0.00
August 0.463712E+10 0.126931E+10 695.99 0.431528E+10 0.321842E+09 0.00 1.00 03-AUG-19:12 0.00 03-AUG-17:42 7173.72 04-AUG-09:12 6472.51 23-AUG-08:12 2323.34 04-AUG-09:13 1516.63 10-AUG-07:12 0.00
September 0.372686E+10 0.996657E+09 634.28 0.343207E+10 0.294786E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-05:13 7370.83 03-SEP-11:22 6610.05 20-SEP-07:52 3095.21 03-SEP-11:23 1530.90 12-SEP-07:52 0.00
October 0.144129E+10 0.384729E+09 331.63 0.139254E+10 48756433.63 0.00 1.00 01-OCT-07:42 0.00 01-OCT-05:13 7096.92 03-OCT-08:62 6642.36 21-OCT-20:02 2115.14 03-OCT-08:03 1513.17 03-OCT-08:62 0.00
November 0.200416E+09 51487747.79 74.50 0.194351E+09 6064722.10 0.00 1.00 01-NOV-11:12 0.00 01-NOV-00:10 7155.92 11-NOV-22:52 6634.20 01-NOV-19:52 2546.29 11-NOV-22:52 1471.38 01-NOV-11:12 0.00
December 16966476.04 4464002.50 13.01 16966476.04 -0.0 0.00 0.51 24-DEC-14:43 0.00 01-DEC-00:10 2962.43 24-DEC-14:43 2962.43 24-DEC-14:43 0.00 24-DEC-14:43 716.70 24-DEC-14:43 0.00
                                       
Annual Sum or Average 0.263071E+11 0.717998E+10 4407.82 0.252895E+11 0.101765E+10 0.00                         0.00
Minimum of Months 2723888.13 674973.66 4.40 2516460.60 -0.0 0.00 0.51   0.00   2962.43   2962.43   0.00   716.70   0.00
Maximum of Months 0.510202E+10 0.139754E+10 722.17 0.494258E+10 0.339772E+09 0.00 1.00   0.00   7370.83   6691.24   3095.21   1530.90   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT TN1 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 84581229.84 22024695.54 58.37 83784647.71 796582.13 0.00 1.00 08-JAN-20:12 0.00 01-JAN-00:10 6279.61 08-JAN-20:12 5239.40 28-JAN-14:42 1682.27 08-JAN-20:12 1307.70 08-JAN-20:12 0.00
February 5729806.54 1422135.71 10.01 5333168.75 396637.79 0.00 0.79 18-FEB-19:12 0.00 01-FEB-00:10 4600.76 18-FEB-19:12 4108.99 22-FEB-20:32 663.08 18-FEB-19:12 1019.59 18-FEB-19:12 0.00
March 0.286273E+09 73535791.45 122.05 0.285960E+09 313446.24 0.00 1.00 09-MAR-18:32 0.00 01-MAR-00:10 5923.97 11-MAR-18:52 5916.17 18-MAR-11:32 175.24 05-MAR-22:52 1316.48 17-MAR-11:22 0.00
April 0.184595E+10 0.496452E+09 506.33 0.184593E+10 21646.80 0.00 1.00 02-APR-09:32 0.00 01-APR-00:10 5892.04 16-APR-12:22 5892.04 16-APR-12:22 2.54 17-APR-02:50 1317.21 16-APR-13:42 0.00
May 0.269889E+10 0.739508E+09 629.78 0.269889E+10 -0.0 0.00 1.00 01-MAY-10:42 0.00 01-MAY-03:00 5843.77 11-MAY-08:62 5843.77 11-MAY-08:62 0.00 12-MAY-08:42 1315.62 18-MAY-08:12 0.00
June 0.386126E+10 0.110007E+10 677.06 0.385604E+10 5222406.25 0.00 1.00 01-JUN-07:22 0.00 01-JUN-05:15 5895.34 04-JUN-06:42 5895.34 04-JUN-06:42 154.71 17-JUN-17:10 1333.14 23-JUN-07:02 0.00
July 0.408161E+10 0.112323E+10 720.35 0.377703E+10 0.304578E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 6455.44 15-JUL-06:42 5780.97 06-JUL-07:12 2128.98 15-JUL-06:43 1362.13 29-JUL-08:12 0.00
August 0.371580E+10 0.102102E+10 693.45 0.342549E+10 0.290303E+09 0.00 1.00 03-AUG-19:12 0.00 03-AUG-17:42 6439.18 04-AUG-09:12 5808.89 23-AUG-08:12 2064.32 04-AUG-09:13 1361.47 10-AUG-07:12 0.00
September 0.307482E+10 0.823867E+09 630.78 0.280850E+10 0.266319E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-05:13 6617.30 03-SEP-11:22 5925.55 20-SEP-07:52 2762.50 03-SEP-11:23 1374.47 12-SEP-07:52 0.00
October 0.118706E+10 0.317299E+09 355.77 0.114254E+10 44522806.53 0.00 1.00 01-OCT-07:42 0.00 01-OCT-05:13 6371.01 03-OCT-08:62 5967.25 21-OCT-20:02 1930.31 03-OCT-08:03 1358.94 03-OCT-08:62 0.00
November 0.196486E+09 50017930.32 107.09 0.184551E+09 11934639.17 0.00 1.00 01-NOV-11:12 0.00 01-NOV-05:13 6448.54 12-NOV-22:52 5960.86 01-NOV-19:52 2448.53 12-NOV-22:52 1322.15 01-NOV-11:12 0.00
December 11810854.07 3113494.47 12.63 11810854.07 0.00 0.00 0.31 23-DEC-20:12 0.00 01-DEC-00:10 1555.08 23-DEC-20:12 1555.08 23-DEC-20:12 0.00 23-DEC-20:12 388.67 23-DEC-20:12 0.00
                                       
Annual Sum or Average 0.210503E+11 0.577156E+10 4523.66 0.201259E+11 0.924408E+09 0.00                         0.00
Minimum of Months 5729806.54 1422135.71 10.01 5333168.75 -0.0 0.00 0.31   0.00   1555.08   1555.08   0.00   388.67   0.00
Maximum of Months 0.408161E+10 0.112323E+10 720.35 0.385604E+10 0.304578E+09 0.00 1.00   0.00   6617.30   5967.25   2762.50   1374.47   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT TN2 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 85485312.43 22247820.31 58.56 84706740.01 778572.42 0.00 1.00 08-JAN-20:12 0.00 01-JAN-00:10 6253.62 08-JAN-20:12 5565.95 28-JAN-14:42 1678.33 08-JAN-20:12 1302.41 08-JAN-20:12 0.00
February 5924786.96 1469155.93 10.14 5489873.18 434913.79 0.00 0.84 18-FEB-19:12 0.00 01-FEB-00:10 4947.63 18-FEB-19:12 4240.07 18-FEB-19:12 707.56 18-FEB-19:12 1086.07 18-FEB-19:12 0.00
March 0.288492E+09 74083951.76 123.33 0.288157E+09 334642.07 0.00 1.00 09-MAR-18:32 0.00 01-MAR-00:10 5898.67 11-MAR-18:52 5897.58 18-MAR-11:32 184.02 05-MAR-22:52 1311.32 17-MAR-11:22 0.00
April 0.185562E+10 0.498854E+09 506.02 0.185560E+10 22034.73 0.00 1.00 02-APR-09:32 0.00 01-APR-00:10 5869.42 16-APR-12:22 5869.42 16-APR-12:22 2.57 17-APR-02:50 1311.83 16-APR-13:42 0.00
May 0.270792E+10 0.741712E+09 630.46 0.270792E+10 -0.0 0.00 1.00 01-MAY-10:42 0.00 01-MAY-03:00 5822.02 11-MAY-08:62 5822.02 11-MAY-08:62 0.00 12-MAY-08:42 1310.83 18-MAY-08:12 0.00
June 0.386588E+10 0.110107E+10 677.36 0.386066E+10 5229819.52 0.00 1.00 01-JUN-07:22 0.00 01-JUN-05:15 5872.02 04-JUN-06:42 5872.02 04-JUN-06:42 154.78 17-JUN-17:10 1327.78 23-JUN-07:02 0.00
July 0.408869E+10 0.112486E+10 720.49 0.378385E+10 0.304839E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 6429.96 15-JUL-06:42 5757.70 06-JUL-07:12 2120.87 15-JUL-06:43 1356.69 29-JUL-08:12 0.00
August 0.372305E+10 0.102271E+10 693.45 0.343236E+10 0.290693E+09 0.00 1.00 03-AUG-19:12 0.00 03-AUG-17:42 6413.17 04-AUG-09:12 5786.57 23-AUG-08:12 2055.21 04-AUG-09:13 1356.02 10-AUG-07:12 0.00
September 0.308015E+10 0.825072E+09 630.76 0.281347E+10 0.266683E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-05:13 6590.61 03-SEP-11:22 5901.95 20-SEP-07:52 2750.80 03-SEP-11:23 1368.98 12-SEP-07:52 0.00
October 0.119317E+10 0.318840E+09 356.34 0.114858E+10 44587066.00 0.00 1.00 01-OCT-07:42 0.00 01-OCT-05:13 6345.90 03-OCT-08:62 5943.26 21-OCT-20:02 1919.60 03-OCT-08:03 1353.49 03-OCT-08:62 0.00
November 0.193571E+09 49324677.52 106.29 0.182207E+09 11363663.65 0.00 1.00 01-NOV-11:12 0.00 01-NOV-05:13 6417.17 11-NOV-22:52 5936.88 01-NOV-19:52 2374.32 12-NOV-22:52 1316.82 01-NOV-11:12 0.00
December 12088035.11 3187233.17 13.07 12088035.11 -0.0 0.00 0.34 24-DEC-14:43 0.00 01-DEC-00:10 1681.99 24-DEC-14:43 1681.99 24-DEC-14:43 0.00 25-DEC-16:20 419.11 24-DEC-14:43 0.00
                                       
Annual Sum or Average 0.211000E+11 0.578344E+10 4526.25 0.201751E+11 0.924966E+09 0.00                         0.00
Minimum of Months 5924786.96 1469155.93 10.14 5489873.18 -0.0 0.00 0.34   0.00   1681.99   1681.99   0.00   419.11   0.00
Maximum of Months 0.408869E+10 0.112486E+10 720.49 0.386066E+10 0.304839E+09 0.00 1.00   0.00   6590.61   5943.26   2750.80   1368.98   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT TS1 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.986036E+09 0.243003E+09 299.09 0.983327E+09 2708811.12 0.00 1.00 02-JAN-13:12 0.00 01-JAN-00:10 6334.76 08-JAN-20:12 6034.22 22-JAN-15:52 1559.18 08-JAN-20:12 1318.75 31-JAN-17:01 0.00
February 0.325333E+09 80297731.22 166.97 0.321288E+09 4044628.04 0.00 1.00 01-FEB-17:01 0.00 01-FEB-01:40 6177.21 18-FEB-19:12 6019.89 13-FEB-17:01 839.45 18-FEB-19:12 1308.59 18-FEB-19:12 0.00
March 0.589538E+09 0.146507E+09 221.68 0.588083E+09 1455410.72 0.00 1.00 01-MAR-17:02 0.00 01-MAR-00:50 6012.54 11-MAR-18:52 6008.35 11-MAR-18:52 167.77 05-MAR-22:52 1349.09 20-MAR-16:01 0.00
April 0.225966E+10 0.597513E+09 540.40 0.225962E+10 43223.30 0.00 1.00 01-APR-09:42 0.00 01-APR-02:70 5972.33 16-APR-13:22 5972.33 16-APR-13:22 4.20 17-APR-02:20 1390.22 25-APR-16:01 0.00
May 0.259825E+10 0.706099E+09 604.86 0.259825E+10 -0.0 0.00 1.00 01-MAY-16:01 0.00 01-MAY-03:20 5856.99 11-MAY-07:32 5856.99 11-MAY-07:32 0.00 11-MAY-16:02 1396.54 10-MAY-16:01 0.00
June 0.352402E+10 0.999563E+09 652.56 0.351909E+10 4930084.73 0.00 1.00 01-JUN-06:52 0.00 01-JUN-05:15 5915.97 04-JUN-06:42 5915.97 04-JUN-06:42 196.12 17-JUN-17:10 1476.91 30-JUN-16:01 0.00
July 0.388507E+10 0.106110E+10 698.94 0.359952E+10 0.285546E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 6481.78 15-JUL-06:42 5842.29 06-JUL-06:52 2128.89 15-JUL-06:43 1515.57 18-JUL-16:01 0.00
August 0.376159E+10 0.102119E+10 674.24 0.349204E+10 0.269550E+09 0.00 1.00 01-AUG-16:01 0.00 01-AUG-08:62 6443.14 05-AUG-09:12 5892.99 23-AUG-07:22 2014.08 05-AUG-09:13 1503.16 11-AUG-16:01 0.00
September 0.344988E+10 0.912900E+09 623.49 0.319053E+10 0.259347E+09 0.00 1.00 01-SEP-06:52 0.00 01-SEP-05:13 6675.29 03-SEP-10:42 5962.23 20-SEP-07:52 2890.36 03-SEP-10:43 1488.67 06-SEP-16:01 0.00
October 0.203094E+10 0.524866E+09 474.24 0.198533E+10 45610961.27 0.00 1.00 01-OCT-07:32 0.00 01-OCT-05:13 6404.49 03-OCT-07:22 6085.56 07-OCT-15:52 1805.47 03-OCT-07:22 1469.30 03-OCT-16:01 0.00
November 0.959864E+09 0.236815E+09 321.07 0.937105E+09 22759012.89 0.00 1.00 01-NOV-16:01 0.00 01-NOV-05:13 6498.51 13-NOV-17:01 6037.41 18-NOV-13:52 2446.46 12-NOV-22:52 1356.88 01-NOV-16:01 0.00
December 0.533834E+09 0.131807E+09 196.06 0.533834E+09 0.00 0.00 1.00 01-DEC-17:01 0.00 01-DEC-00:10 5919.99 13-DEC-17:01 5919.99 13-DEC-17:01 0.00 04-DEC-17:03 1289.24 13-DEC-17:01 0.00
                                       
Annual Sum or Average 0.249040E+11 0.666166E+10 5473.61 0.240080E+11 0.895995E+09 0.00                         0.00
Minimum of Months 0.325333E+09 80297731.22 166.97 0.321288E+09 -0.0 0.00 1.00   0.00   5856.99   5842.29   0.00   1289.24   0.00
Maximum of Months 0.388507E+10 0.106110E+10 698.94 0.359952E+10 0.285546E+09 0.00 1.00   0.00   6675.29   6085.56   2890.36   1515.57   0.00



Table of Contents

Report: DXReportMonthly

For: SPLIT TS2 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.991272E+09 0.244255E+09 299.90 0.988552E+09 2720728.05 0.00 1.00 02-JAN-13:12 0.00 01-JAN-00:10 6309.43 08-JAN-20:12 6011.55 22-JAN-15:52 1554.07 08-JAN-20:12 1313.50 31-JAN-17:01 0.00
February 0.333034E+09 82195011.09 169.29 0.328833E+09 4201009.97 0.00 1.00 01-FEB-17:01 0.00 01-FEB-01:40 6154.41 18-FEB-19:12 5996.20 14-FEB-17:01 831.48 18-FEB-19:12 1303.47 18-FEB-19:12 0.00
March 0.595368E+09 0.147929E+09 224.63 0.593874E+09 1494236.47 0.00 1.00 01-MAR-17:02 0.00 01-MAR-00:50 6004.82 04-MAR-13:52 6004.82 04-MAR-13:52 161.78 05-MAR-22:52 1343.71 20-MAR-16:01 0.00
April 0.227013E+10 0.600132E+09 542.57 0.227008E+10 43890.68 0.00 1.00 01-APR-09:42 0.00 01-APR-02:70 5954.46 16-APR-13:22 5954.46 16-APR-13:22 4.25 17-APR-02:20 1384.68 25-APR-16:01 0.00
May 0.260906E+10 0.708937E+09 607.02 0.260906E+10 0.00 0.00 1.00 01-MAY-16:01 0.00 01-MAY-03:20 5838.54 11-MAY-07:32 5838.54 11-MAY-07:32 0.00 10-MAY-07:42 1390.99 10-MAY-16:01 0.00
June 0.353123E+10 0.100149E+10 653.39 0.352629E+10 4934996.58 0.00 1.00 01-JUN-06:52 0.00 01-JUN-05:15 5892.76 04-JUN-06:42 5892.76 04-JUN-06:42 196.21 17-JUN-17:10 1471.04 30-JUN-16:01 0.00
July 0.389423E+10 0.106341E+10 699.44 0.360834E+10 0.285888E+09 0.00 1.00 01-JUL-07:52 0.00 01-JUL-05:15 6456.29 15-JUL-06:42 5818.97 06-JUL-06:52 2120.04 15-JUL-06:43 1509.42 18-JUL-16:01 0.00
August 0.377100E+10 0.102356E+10 675.00 0.350105E+10 0.269949E+09 0.00 1.00 01-AUG-16:01 0.00 01-AUG-08:62 6416.36 05-AUG-09:12 5869.91 23-AUG-07:22 2003.50 05-AUG-09:13 1497.15 11-AUG-16:01 0.00
September 0.345626E+10 0.914395E+09 623.79 0.319656E+10 0.259705E+09 0.00 1.00 01-SEP-06:52 0.00 01-SEP-05:13 6648.54 03-SEP-10:42 5938.72 20-SEP-07:52 2878.33 03-SEP-10:43 1482.70 06-SEP-16:01 0.00
October 0.203996E+10 0.527058E+09 476.68 0.199425E+10 45703051.04 0.00 1.00 01-OCT-07:32 0.00 01-OCT-05:13 6379.09 03-OCT-07:22 6059.14 07-OCT-15:52 1801.85 03-OCT-07:23 1463.37 03-OCT-16:01 0.00
November 0.962513E+09 0.237476E+09 321.58 0.940133E+09 22379960.89 0.00 1.00 01-NOV-16:01 0.00 01-NOV-05:13 6470.82 13-NOV-17:01 6015.49 18-NOV-13:52 2439.93 12-NOV-22:52 1351.46 01-NOV-16:01 0.00
December 0.538325E+09 0.132908E+09 197.99 0.538325E+09 -0.0 0.00 1.00 01-DEC-17:01 0.00 01-DEC-00:10 5896.37 13-DEC-17:01 5896.37 13-DEC-17:01 0.00 03-DEC-12:52 1284.10 13-DEC-17:01 0.00
                                       
Annual Sum or Average 0.249924E+11 0.668375E+10 5491.30 0.240954E+11 0.897019E+09 0.00                         0.00
Minimum of Months 0.333034E+09 82195011.09 169.29 0.328833E+09 -0.0 0.00 1.00   0.00   5838.54   5818.97   0.00   1284.10   0.00
Maximum of Months 0.389423E+10 0.106341E+10 699.44 0.360834E+10 0.285888E+09 0.00 1.00   0.00   6648.54   6059.14   2878.33   1509.42   0.00



Table of Contents

Report: WindowReportMonthly

For: GWINDOW1 S SWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 244.00 194.57 49.43 374.98 139.61 0.00 0.00 0.00
February 157.28 106.75 50.53 218.58 131.95 0.00 0.00 0.00
March 123.66 61.05 62.61 185.72 117.96 0.00 0.00 0.00
April 114.25 48.73 65.51 218.10 65.16 0.00 0.00 0.00
May 73.79 12.30 61.49 155.59 43.04 0.00 0.00 0.00
June 63.39 5.18 58.21 180.31 15.43 0.00 0.00 0.00
July 64.37 6.59 57.78 176.86 11.30 0.00 0.00 0.00
August 78.89 22.17 56.71 201.12 16.17 0.00 0.00 0.00
September 113.16 48.41 64.75 241.39 25.16 0.00 0.00 0.00
October 179.97 124.58 55.39 303.08 86.83 0.00 0.00 0.00
November 212.09 163.00 49.09 318.09 131.00 0.00 0.00 0.00
December 227.87 180.33 47.54 331.85 169.48 0.00 0.00 0.00
                 
Annual Sum or Average 137.70 81.09 56.61 242.36 79.21 0.00 0.00 0.00
Minimum of Months 63.39 5.18 47.54 155.59 11.30 0.00 0.00 0.00
Maximum of Months 244.00 194.57 65.51 374.98 169.48 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: GWINDOW1 W SWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 66.67 41.57 25.10 92.68 100.66 0.00 0.00 0.00
February 53.58 25.86 27.72 61.12 93.36 0.00 0.00 0.00
March 71.48 34.25 37.22 97.37 78.09 0.00 0.00 0.00
April 109.04 62.15 46.89 189.11 42.46 0.00 0.00 0.00
May 109.52 61.30 48.22 204.08 28.23 0.00 0.00 0.00
June 116.40 68.52 47.87 248.72 10.44 0.00 0.00 0.00
July 84.66 39.52 45.14 188.06 7.66 0.00 0.00 0.00
August 80.88 40.64 40.25 175.03 10.91 0.00 0.00 0.00
September 70.45 29.64 40.81 143.05 16.98 0.00 0.00 0.00
October 71.98 41.13 30.84 115.09 61.14 0.00 0.00 0.00
November 66.05 39.78 26.28 88.54 94.12 0.00 0.00 0.00
December 53.41 30.39 23.02 64.44 123.53 0.00 0.00 0.00
                 
Annual Sum or Average 79.60 42.96 36.64 139.27 55.48 0.00 0.00 0.00
Minimum of Months 53.41 25.86 23.02 61.12 7.66 0.00 0.00 0.00
Maximum of Months 116.40 68.52 48.22 248.72 123.53 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: GWINDOW1 W NWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 66.67 41.57 25.10 99.24 91.02 0.00 0.00 0.00
February 53.58 25.86 27.72 65.99 83.53 0.00 0.00 0.00
March 71.48 34.25 37.22 102.29 72.31 0.00 0.00 0.00
April 109.04 62.15 46.89 193.60 40.53 0.00 0.00 0.00
May 109.52 61.30 48.22 208.16 27.24 0.00 0.00 0.00
June 116.40 68.52 47.87 253.30 9.96 0.00 0.00 0.00
July 84.66 39.52 45.14 192.45 7.17 0.00 0.00 0.00
August 80.88 40.64 40.25 180.50 9.87 0.00 0.00 0.00
September 70.45 29.64 40.81 148.41 15.49 0.00 0.00 0.00
October 71.98 41.13 30.84 119.80 58.39 0.00 0.00 0.00
November 66.05 39.78 26.28 93.08 89.28 0.00 0.00 0.00
December 53.41 30.39 23.02 69.54 113.56 0.00 0.00 0.00
                 
Annual Sum or Average 79.60 42.96 36.64 144.19 51.41 0.00 0.00 0.00
Minimum of Months 53.41 25.86 23.02 65.99 7.17 0.00 0.00 0.00
Maximum of Months 116.40 68.52 48.22 253.30 113.56 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: GWINDOW1 N NWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 29.81 0.00 29.81 22.05 140.56 0.00 0.00 0.00
February 33.96 0.00 33.96 18.10 130.20 0.00 0.00 0.00
March 45.15 0.01 45.14 45.94 112.92 0.00 0.00 0.00
April 55.17 0.73 54.44 95.27 60.58 0.00 0.00 0.00
May 64.98 5.63 59.35 132.61 37.44 0.00 0.00 0.00
June 74.53 13.34 61.19 206.09 13.46 0.00 0.00 0.00
July 63.60 6.45 57.15 177.65 10.07 0.00 0.00 0.00
August 51.66 1.38 50.27 144.85 14.40 0.00 0.00 0.00
September 48.61 0.03 48.58 118.90 23.61 0.00 0.00 0.00
October 37.59 0.00 37.59 53.60 90.70 0.00 0.00 0.00
November 31.32 0.00 31.32 19.51 138.89 0.00 0.00 0.00
December 27.84 0.00 27.84 11.21 176.88 0.00 0.00 0.00
                 
Annual Sum or Average 47.07 2.30 44.76 87.47 78.94 0.00 0.00 0.00
Minimum of Months 27.84 0.00 27.84 11.21 10.07 0.00 0.00 0.00
Maximum of Months 74.53 13.34 61.19 206.09 176.88 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: GWINDOW1 S SEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 244.00 194.57 49.43 377.51 142.17 0.00 0.00 0.00
February 157.28 106.75 50.53 220.34 131.50 0.00 0.00 0.00
March 123.66 61.05 62.61 185.68 120.03 0.00 0.00 0.00
April 114.25 48.73 65.51 212.66 79.01 0.00 0.00 0.00
May 73.79 12.30 61.49 147.60 59.21 0.00 0.00 0.00
June 63.39 5.18 58.21 163.20 29.70 0.00 0.00 0.00
July 64.37 6.59 57.78 155.37 26.35 0.00 0.00 0.00
August 78.89 22.17 56.71 187.39 33.60 0.00 0.00 0.00
September 113.16 48.41 64.75 229.65 45.81 0.00 0.00 0.00
October 179.97 124.58 55.39 298.79 103.32 0.00 0.00 0.00
November 212.09 163.00 49.09 320.41 137.83 0.00 0.00 0.00
December 227.87 180.33 47.54 334.29 170.53 0.00 0.00 0.00
                 
Annual Sum or Average 137.70 81.09 56.61 236.25 89.76 0.00 0.00 0.00
Minimum of Months 63.39 5.18 47.54 147.60 26.35 0.00 0.00 0.00
Maximum of Months 244.00 194.57 65.51 377.51 170.53 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: GWINDOW1 E SEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 63.64 40.03 23.61 78.80 94.50 0.00 0.00 0.00
February 62.52 35.77 26.75 71.72 87.80 0.00 0.00 0.00
March 77.97 40.00 37.97 103.77 75.06 0.00 0.00 0.00
April 111.66 66.61 45.05 185.07 47.32 0.00 0.00 0.00
May 115.71 68.62 47.08 204.49 34.68 0.00 0.00 0.00
June 120.57 74.94 45.62 242.15 17.40 0.00 0.00 0.00
July 101.97 57.59 44.38 203.07 15.84 0.00 0.00 0.00
August 96.66 55.18 41.48 192.29 20.82 0.00 0.00 0.00
September 79.25 38.19 41.06 148.47 28.51 0.00 0.00 0.00
October 79.52 48.36 31.16 120.11 67.42 0.00 0.00 0.00
November 61.24 36.75 24.49 73.88 92.41 0.00 0.00 0.00
December 55.77 33.67 22.10 59.04 114.98 0.00 0.00 0.00
                 
Annual Sum or Average 85.65 49.71 35.94 140.56 57.94 0.00 0.00 0.00
Minimum of Months 55.77 33.67 22.10 59.04 15.84 0.00 0.00 0.00
Maximum of Months 120.57 74.94 47.08 242.15 114.98 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: GWINDOW1 E NEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 63.64 40.03 23.61 84.33 83.22 0.00 0.00 0.00
February 62.52 35.77 26.75 75.24 79.18 0.00 0.00 0.00
March 77.97 40.00 37.97 107.87 68.07 0.00 0.00 0.00
April 111.66 66.61 45.05 192.83 36.87 0.00 0.00 0.00
May 115.71 68.62 47.08 213.94 24.00 0.00 0.00 0.00
June 120.57 74.94 45.62 258.32 8.39 0.00 0.00 0.00
July 101.97 57.59 44.38 221.98 6.21 0.00 0.00 0.00
August 96.66 55.18 41.48 206.92 8.91 0.00 0.00 0.00
September 79.25 38.19 41.06 161.92 14.07 0.00 0.00 0.00
October 79.52 48.36 31.16 127.33 53.88 0.00 0.00 0.00
November 61.24 36.75 24.49 76.96 82.55 0.00 0.00 0.00
December 55.77 33.67 22.10 63.03 104.96 0.00 0.00 0.00
                 
Annual Sum or Average 85.65 49.71 35.94 149.58 47.40 0.00 0.00 0.00
Minimum of Months 55.77 33.67 22.10 63.03 6.21 0.00 0.00 0.00
Maximum of Months 120.57 74.94 47.08 258.32 104.96 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: GWINDOW1 N NEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 29.81 0.00 29.81 21.54 139.89 0.00 0.00 0.00
February 33.96 0.00 33.96 17.20 131.13 0.00 0.00 0.00
March 45.15 0.01 45.14 44.76 113.28 0.00 0.00 0.00
April 55.17 0.73 54.44 94.19 60.45 0.00 0.00 0.00
May 64.98 5.63 59.35 131.62 37.28 0.00 0.00 0.00
June 74.53 13.34 61.19 205.58 13.33 0.00 0.00 0.00
July 63.60 6.45 57.15 176.96 10.04 0.00 0.00 0.00
August 51.66 1.38 50.27 144.21 14.42 0.00 0.00 0.00
September 48.61 0.03 48.58 118.44 23.61 0.00 0.00 0.00
October 37.59 0.00 37.59 52.81 90.68 0.00 0.00 0.00
November 31.32 0.00 31.32 19.16 138.10 0.00 0.00 0.00
December 27.84 0.00 27.84 10.78 177.04 0.00 0.00 0.00
                 
Annual Sum or Average 47.07 2.30 44.76 86.75 78.90 0.00 0.00 0.00
Minimum of Months 27.84 0.00 27.84 10.78 10.04 0.00 0.00 0.00
Maximum of Months 74.53 13.34 61.19 205.58 177.04 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: GWINDOW1 N N1A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 29.81 0.00 29.81 21.22 143.88 0.00 0.00 0.00
February 33.96 0.00 33.96 16.20 138.84 0.00 0.00 0.00
March 45.15 0.01 45.14 43.82 118.32 0.00 0.00 0.00
April 55.17 0.73 54.44 96.14 60.46 0.00 0.00 0.00
May 64.98 5.63 59.35 133.78 37.17 0.00 0.00 0.00
June 74.53 13.34 61.19 208.88 13.04 0.00 0.00 0.00
July 63.60 6.45 57.15 180.40 9.63 0.00 0.00 0.00
August 51.66 1.38 50.27 147.52 13.76 0.00 0.00 0.00
September 48.61 0.03 48.58 121.19 22.70 0.00 0.00 0.00
October 37.59 0.00 37.59 54.60 89.93 0.00 0.00 0.00
November 31.32 0.00 31.32 19.71 139.01 0.00 0.00 0.00
December 27.84 0.00 27.84 10.50 181.85 0.00 0.00 0.00
                 
Annual Sum or Average 47.07 2.30 44.76 88.16 80.48 0.00 0.00 0.00
Minimum of Months 27.84 0.00 27.84 10.50 9.63 0.00 0.00 0.00
Maximum of Months 74.53 13.34 61.19 208.88 181.85 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: GWINDOW1 N N2A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 29.81 0.00 29.81 21.20 143.82 0.00 0.00 0.00
February 33.96 0.00 33.96 16.11 139.04 0.00 0.00 0.00
March 45.15 0.01 45.14 43.72 118.45 0.00 0.00 0.00
April 55.17 0.73 54.44 96.07 60.47 0.00 0.00 0.00
May 64.98 5.63 59.35 133.74 37.17 0.00 0.00 0.00
June 74.53 13.34 61.19 208.86 13.03 0.00 0.00 0.00
July 63.60 6.45 57.15 180.37 9.63 0.00 0.00 0.00
August 51.66 1.38 50.27 147.49 13.77 0.00 0.00 0.00
September 48.61 0.03 48.58 121.17 22.70 0.00 0.00 0.00
October 37.59 0.00 37.59 54.54 89.96 0.00 0.00 0.00
November 31.32 0.00 31.32 19.70 138.95 0.00 0.00 0.00
December 27.84 0.00 27.84 10.47 181.91 0.00 0.00 0.00
                 
Annual Sum or Average 47.07 2.30 44.76 88.12 80.50 0.00 0.00 0.00
Minimum of Months 27.84 0.00 27.84 10.47 9.63 0.00 0.00 0.00
Maximum of Months 74.53 13.34 61.19 208.86 181.91 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: GWINDOW1 S S1A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 244.00 194.57 49.43 373.73 141.50 0.00 0.00 0.00
February 157.28 106.75 50.53 215.76 137.93 0.00 0.00 0.00
March 123.66 61.05 62.61 183.17 122.33 0.00 0.00 0.00
April 114.25 48.73 65.51 218.65 65.26 0.00 0.00 0.00
May 73.79 12.30 61.49 156.72 42.93 0.00 0.00 0.00
June 63.39 5.18 58.21 183.09 15.02 0.00 0.00 0.00
July 64.37 6.59 57.78 179.57 10.86 0.00 0.00 0.00
August 78.89 22.17 56.71 203.66 15.53 0.00 0.00 0.00
September 113.16 48.41 64.75 243.43 24.32 0.00 0.00 0.00
October 179.97 124.58 55.39 303.66 86.61 0.00 0.00 0.00
November 212.09 163.00 49.09 317.87 131.60 0.00 0.00 0.00
December 227.87 180.33 47.54 330.40 171.79 0.00 0.00 0.00
                 
Annual Sum or Average 137.70 81.09 56.61 242.71 80.23 0.00 0.00 0.00
Minimum of Months 63.39 5.18 47.54 156.72 10.86 0.00 0.00 0.00
Maximum of Months 244.00 194.57 65.51 373.73 171.79 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: GWINDOW1 S S2A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 244.00 194.57 49.43 373.78 141.41 0.00 0.00 0.00
February 157.28 106.75 50.53 215.80 137.76 0.00 0.00 0.00
March 123.66 61.05 62.61 183.08 122.33 0.00 0.00 0.00
April 114.25 48.73 65.51 218.18 65.76 0.00 0.00 0.00
May 73.79 12.30 61.49 156.00 43.53 0.00 0.00 0.00
June 63.39 5.18 58.21 182.06 15.47 0.00 0.00 0.00
July 64.37 6.59 57.78 178.43 11.29 0.00 0.00 0.00
August 78.89 22.17 56.71 202.77 16.08 0.00 0.00 0.00
September 113.16 48.41 64.75 242.65 25.04 0.00 0.00 0.00
October 179.97 124.58 55.39 303.19 87.19 0.00 0.00 0.00
November 212.09 163.00 49.09 317.79 131.75 0.00 0.00 0.00
December 227.87 180.33 47.54 330.45 171.68 0.00 0.00 0.00
                 
Annual Sum or Average 137.70 81.09 56.61 242.25 80.54 0.00 0.00 0.00
Minimum of Months 63.39 5.18 47.54 156.00 11.29 0.00 0.00 0.00
Maximum of Months 244.00 194.57 65.51 373.78 171.68 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: MWINDOW1 S SWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 244.00 194.57 49.43 371.10 142.26 0.00 0.00 0.00
February 157.28 106.75 50.53 211.88 141.60 0.00 0.00 0.00
March 123.66 61.05 62.61 177.91 127.79 0.00 0.00 0.00
April 114.25 48.73 65.51 215.14 66.57 0.00 0.00 0.00
May 73.79 12.30 61.49 153.33 43.69 0.00 0.00 0.00
June 63.39 5.18 58.21 180.27 15.06 0.00 0.00 0.00
July 64.37 6.59 57.78 178.85 10.34 0.00 0.00 0.00
August 78.89 22.17 56.71 203.20 14.46 0.00 0.00 0.00
September 113.16 48.41 64.75 243.62 22.23 0.00 0.00 0.00
October 179.97 124.58 55.39 303.28 84.48 0.00 0.00 0.00
November 212.09 163.00 49.09 317.11 129.75 0.00 0.00 0.00
December 227.87 180.33 47.54 330.17 169.56 0.00 0.00 0.00
                 
Annual Sum or Average 137.70 81.09 56.61 240.74 80.39 0.00 0.00 0.00
Minimum of Months 63.39 5.18 47.54 153.33 10.34 0.00 0.00 0.00
Maximum of Months 244.00 194.57 65.51 371.10 169.56 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: MWINDOW1 W SWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 66.67 41.57 25.10 91.08 102.61 0.00 0.00 0.00
February 53.58 25.86 27.72 57.85 100.39 0.00 0.00 0.00
March 71.48 34.25 37.22 92.44 84.48 0.00 0.00 0.00
April 109.04 62.15 46.89 187.00 43.39 0.00 0.00 0.00
May 109.52 61.30 48.22 202.14 28.69 0.00 0.00 0.00
June 116.40 68.52 47.87 248.11 10.25 0.00 0.00 0.00
July 84.66 39.52 45.14 189.05 7.08 0.00 0.00 0.00
August 80.88 40.64 40.25 176.24 9.87 0.00 0.00 0.00
September 70.45 29.64 40.81 144.61 15.14 0.00 0.00 0.00
October 71.98 41.13 30.84 115.45 59.46 0.00 0.00 0.00
November 66.05 39.78 26.28 88.21 93.13 0.00 0.00 0.00
December 53.41 30.39 23.02 63.81 123.47 0.00 0.00 0.00
                 
Annual Sum or Average 79.60 42.96 36.64 138.34 56.31 0.00 0.00 0.00
Minimum of Months 53.41 25.86 23.02 57.85 7.08 0.00 0.00 0.00
Maximum of Months 116.40 68.52 48.22 248.11 123.47 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: MWINDOW1 W NWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 66.67 41.57 25.10 96.98 95.78 0.00 0.00 0.00
February 53.58 25.86 27.72 61.76 95.07 0.00 0.00 0.00
March 71.48 34.25 37.22 96.30 81.63 0.00 0.00 0.00
April 109.04 62.15 46.89 191.56 41.98 0.00 0.00 0.00
May 109.52 61.30 48.22 206.77 27.77 0.00 0.00 0.00
June 116.40 68.52 47.87 253.26 9.81 0.00 0.00 0.00
July 84.66 39.52 45.14 193.76 6.66 0.00 0.00 0.00
August 80.88 40.64 40.25 182.06 9.01 0.00 0.00 0.00
September 70.45 29.64 40.81 150.21 13.96 0.00 0.00 0.00
October 71.98 41.13 30.84 120.66 56.83 0.00 0.00 0.00
November 66.05 39.78 26.28 93.41 87.75 0.00 0.00 0.00
December 53.41 30.39 23.02 69.57 112.76 0.00 0.00 0.00
                 
Annual Sum or Average 79.60 42.96 36.64 143.37 53.07 0.00 0.00 0.00
Minimum of Months 53.41 25.86 23.02 61.76 6.66 0.00 0.00 0.00
Maximum of Months 116.40 68.52 48.22 253.26 112.76 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: MWINDOW1 N NWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 29.81 0.00 29.81 19.72 148.06 0.00 0.00 0.00
February 33.96 0.00 33.96 13.29 148.63 0.00 0.00 0.00
March 45.15 0.01 45.14 38.78 128.12 0.00 0.00 0.00
April 55.17 0.73 54.44 93.25 62.78 0.00 0.00 0.00
May 64.98 5.63 59.35 131.17 38.09 0.00 0.00 0.00
June 74.53 13.34 61.19 206.74 13.23 0.00 0.00 0.00
July 63.60 6.45 57.15 180.14 9.34 0.00 0.00 0.00
August 51.66 1.38 50.27 147.76 13.12 0.00 0.00 0.00
September 48.61 0.03 48.58 122.23 21.25 0.00 0.00 0.00
October 37.59 0.00 37.59 55.47 88.08 0.00 0.00 0.00
November 31.32 0.00 31.32 20.49 136.19 0.00 0.00 0.00
December 27.84 0.00 27.84 11.59 175.32 0.00 0.00 0.00
                 
Annual Sum or Average 47.07 2.30 44.76 87.06 81.56 0.00 0.00 0.00
Minimum of Months 27.84 0.00 27.84 11.59 9.34 0.00 0.00 0.00
Maximum of Months 74.53 13.34 61.19 206.74 175.32 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: MWINDOW1 S SEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 244.00 194.57 49.43 370.19 141.83 0.00 0.00 0.00
February 157.28 106.75 50.53 210.64 141.79 0.00 0.00 0.00
March 123.66 61.05 62.61 176.44 127.66 0.00 0.00 0.00
April 114.25 48.73 65.51 213.59 66.52 0.00 0.00 0.00
May 73.79 12.30 61.49 151.88 43.74 0.00 0.00 0.00
June 63.39 5.18 58.21 179.23 15.03 0.00 0.00 0.00
July 64.37 6.59 57.78 177.79 10.36 0.00 0.00 0.00
August 78.89 22.17 56.71 202.18 14.54 0.00 0.00 0.00
September 113.16 48.41 64.75 242.89 22.25 0.00 0.00 0.00
October 179.97 124.58 55.39 302.01 84.38 0.00 0.00 0.00
November 212.09 163.00 49.09 316.39 129.19 0.00 0.00 0.00
December 227.87 180.33 47.54 329.16 169.44 0.00 0.00 0.00
                 
Annual Sum or Average 137.70 81.09 56.61 239.62 80.30 0.00 0.00 0.00
Minimum of Months 63.39 5.18 47.54 151.88 10.36 0.00 0.00 0.00
Maximum of Months 244.00 194.57 65.51 370.19 169.44 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: MWINDOW1 E SEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 63.64 40.03 23.61 75.35 94.67 0.00 0.00 0.00
February 62.52 35.77 26.75 66.73 95.48 0.00 0.00 0.00
March 77.97 40.00 37.97 97.52 79.63 0.00 0.00 0.00
April 111.66 66.61 45.05 185.77 39.52 0.00 0.00 0.00
May 115.71 68.62 47.08 207.25 25.30 0.00 0.00 0.00
June 120.57 74.94 45.62 252.59 8.64 0.00 0.00 0.00
July 101.97 57.59 44.38 218.14 6.12 0.00 0.00 0.00
August 96.66 55.18 41.48 202.18 8.90 0.00 0.00 0.00
September 79.25 38.19 41.06 157.89 13.72 0.00 0.00 0.00
October 79.52 48.36 31.16 122.84 55.09 0.00 0.00 0.00
November 61.24 36.75 24.49 72.39 86.94 0.00 0.00 0.00
December 55.77 33.67 22.10 57.43 115.31 0.00 0.00 0.00
                 
Annual Sum or Average 85.65 49.71 35.94 143.37 52.26 0.00 0.00 0.00
Minimum of Months 55.77 33.67 22.10 57.43 6.12 0.00 0.00 0.00
Maximum of Months 120.57 74.94 47.08 252.59 115.31 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: MWINDOW1 E NEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 63.64 40.03 23.61 81.49 87.51 0.00 0.00 0.00
February 62.52 35.77 26.75 70.38 89.78 0.00 0.00 0.00
March 77.97 40.00 37.97 101.32 76.62 0.00 0.00 0.00
April 111.66 66.61 45.05 190.47 38.08 0.00 0.00 0.00
May 115.71 68.62 47.08 212.27 24.37 0.00 0.00 0.00
June 120.57 74.94 45.62 258.15 8.19 0.00 0.00 0.00
July 101.97 57.59 44.38 223.20 5.70 0.00 0.00 0.00
August 96.66 55.18 41.48 208.36 8.03 0.00 0.00 0.00
September 79.25 38.19 41.06 163.77 12.60 0.00 0.00 0.00
October 79.52 48.36 31.16 128.14 52.40 0.00 0.00 0.00
November 61.24 36.75 24.49 77.32 81.14 0.00 0.00 0.00
December 55.77 33.67 22.10 63.01 104.42 0.00 0.00 0.00
                 
Annual Sum or Average 85.65 49.71 35.94 148.53 48.89 0.00 0.00 0.00
Minimum of Months 55.77 33.67 22.10 63.01 5.70 0.00 0.00 0.00
Maximum of Months 120.57 74.94 47.08 258.15 104.42 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: MWINDOW1 N NEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 29.81 0.00 29.81 19.14 147.12 0.00 0.00 0.00
February 33.96 0.00 33.96 12.59 149.07 0.00 0.00 0.00
March 45.15 0.01 45.14 37.70 128.02 0.00 0.00 0.00
April 55.17 0.73 54.44 92.01 62.59 0.00 0.00 0.00
May 64.98 5.63 59.35 130.05 37.89 0.00 0.00 0.00
June 74.53 13.34 61.19 206.21 13.09 0.00 0.00 0.00
July 63.60 6.45 57.15 179.49 9.29 0.00 0.00 0.00
August 51.66 1.38 50.27 147.12 13.11 0.00 0.00 0.00
September 48.61 0.03 48.58 121.72 21.24 0.00 0.00 0.00
October 37.59 0.00 37.59 54.49 88.06 0.00 0.00 0.00
November 31.32 0.00 31.32 20.00 135.37 0.00 0.00 0.00
December 27.84 0.00 27.84 11.03 175.56 0.00 0.00 0.00
                 
Annual Sum or Average 47.07 2.30 44.76 86.30 81.41 0.00 0.00 0.00
Minimum of Months 27.84 0.00 27.84 11.03 9.29 0.00 0.00 0.00
Maximum of Months 74.53 13.34 61.19 206.21 175.56 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: MWINDOW1 N N1A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 29.81 0.00 29.81 19.21 150.27 0.00 0.00 0.00
February 33.96 0.00 33.96 12.57 152.81 0.00 0.00 0.00
March 45.15 0.01 45.14 38.43 129.59 0.00 0.00 0.00
April 55.17 0.73 54.44 94.78 61.97 0.00 0.00 0.00
May 64.98 5.63 59.35 133.12 37.41 0.00 0.00 0.00
June 74.53 13.34 61.19 210.03 12.71 0.00 0.00 0.00
July 63.60 6.45 57.15 182.84 8.97 0.00 0.00 0.00
August 51.66 1.38 50.27 150.19 12.70 0.00 0.00 0.00
September 48.61 0.03 48.58 124.02 20.82 0.00 0.00 0.00
October 37.59 0.00 37.59 56.11 87.85 0.00 0.00 0.00
November 31.32 0.00 31.32 20.23 137.83 0.00 0.00 0.00
December 27.84 0.00 27.84 10.42 182.56 0.00 0.00 0.00
                 
Annual Sum or Average 47.07 2.30 44.76 88.01 82.65 0.00 0.00 0.00
Minimum of Months 27.84 0.00 27.84 10.42 8.97 0.00 0.00 0.00
Maximum of Months 74.53 13.34 61.19 210.03 182.56 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: MWINDOW1 N N2A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 29.81 0.00 29.81 19.18 150.21 0.00 0.00 0.00
February 33.96 0.00 33.96 12.53 152.87 0.00 0.00 0.00
March 45.15 0.01 45.14 38.36 129.62 0.00 0.00 0.00
April 55.17 0.73 54.44 94.71 61.98 0.00 0.00 0.00
May 64.98 5.63 59.35 133.07 37.41 0.00 0.00 0.00
June 74.53 13.34 61.19 210.01 12.71 0.00 0.00 0.00
July 63.60 6.45 57.15 182.82 8.97 0.00 0.00 0.00
August 51.66 1.38 50.27 150.16 12.70 0.00 0.00 0.00
September 48.61 0.03 48.58 124.00 20.82 0.00 0.00 0.00
October 37.59 0.00 37.59 56.05 87.87 0.00 0.00 0.00
November 31.32 0.00 31.32 20.20 137.79 0.00 0.00 0.00
December 27.84 0.00 27.84 10.38 182.64 0.00 0.00 0.00
                 
Annual Sum or Average 47.07 2.30 44.76 87.97 82.66 0.00 0.00 0.00
Minimum of Months 27.84 0.00 27.84 10.38 8.97 0.00 0.00 0.00
Maximum of Months 74.53 13.34 61.19 210.01 182.64 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: MWINDOW1 S S1A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 244.00 194.57 49.43 370.39 143.47 0.00 0.00 0.00
February 157.28 106.75 50.53 210.80 143.82 0.00 0.00 0.00
March 123.66 61.05 62.61 177.38 128.82 0.00 0.00 0.00
April 114.25 48.73 65.51 216.47 65.96 0.00 0.00 0.00
May 73.79 12.30 61.49 155.41 43.01 0.00 0.00 0.00
June 63.39 5.18 58.21 183.82 14.49 0.00 0.00 0.00
July 64.37 6.59 57.78 181.76 9.95 0.00 0.00 0.00
August 78.89 22.17 56.71 205.68 14.03 0.00 0.00 0.00
September 113.16 48.41 64.75 245.30 21.82 0.00 0.00 0.00
October 179.97 124.58 55.39 303.52 84.66 0.00 0.00 0.00
November 212.09 163.00 49.09 316.61 130.70 0.00 0.00 0.00
December 227.87 180.33 47.54 328.37 172.35 0.00 0.00 0.00
                 
Annual Sum or Average 137.70 81.09 56.61 241.55 80.82 0.00 0.00 0.00
Minimum of Months 63.39 5.18 47.54 155.41 9.95 0.00 0.00 0.00
Maximum of Months 244.00 194.57 65.51 370.39 172.35 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: MWINDOW1 S S2A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 244.00 194.57 49.43 370.35 143.46 0.00 0.00 0.00
February 157.28 106.75 50.53 210.74 143.86 0.00 0.00 0.00
March 123.66 61.05 62.61 177.29 128.86 0.00 0.00 0.00
April 114.25 48.73 65.51 216.38 65.98 0.00 0.00 0.00
May 73.79 12.30 61.49 155.31 43.02 0.00 0.00 0.00
June 63.39 5.18 58.21 183.75 14.49 0.00 0.00 0.00
July 64.37 6.59 57.78 181.69 9.96 0.00 0.00 0.00
August 78.89 22.17 56.71 205.62 14.04 0.00 0.00 0.00
September 113.16 48.41 64.75 245.26 21.83 0.00 0.00 0.00
October 179.97 124.58 55.39 303.46 84.68 0.00 0.00 0.00
November 212.09 163.00 49.09 316.58 130.68 0.00 0.00 0.00
December 227.87 180.33 47.54 328.33 172.36 0.00 0.00 0.00
                 
Annual Sum or Average 137.70 81.09 56.61 241.49 80.84 0.00 0.00 0.00
Minimum of Months 63.39 5.18 47.54 155.31 9.96 0.00 0.00 0.00
Maximum of Months 244.00 194.57 65.51 370.35 172.36 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: TWINDOW1 S SWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 244.00 194.57 49.43 373.87 131.01 0.00 0.00 0.00
February 157.28 106.75 50.53 216.33 124.29 0.00 0.00 0.00
March 123.66 61.05 62.61 181.12 116.48 0.00 0.00 0.00
April 114.25 48.73 65.51 211.91 62.95 0.00 0.00 0.00
May 73.79 12.30 61.49 149.40 40.96 0.00 0.00 0.00
June 63.39 5.18 58.21 174.46 13.86 0.00 0.00 0.00
July 64.37 6.59 57.78 173.27 9.60 0.00 0.00 0.00
August 78.89 22.17 56.71 197.86 13.39 0.00 0.00 0.00
September 113.16 48.41 64.75 238.97 20.61 0.00 0.00 0.00
October 179.97 124.58 55.39 302.14 78.86 0.00 0.00 0.00
November 212.09 163.00 49.09 319.22 119.60 0.00 0.00 0.00
December 227.87 180.33 47.54 336.23 152.43 0.00 0.00 0.00
                 
Annual Sum or Average 137.70 81.09 56.61 239.79 73.47 0.00 0.00 0.00
Minimum of Months 63.39 5.18 47.54 149.40 9.60 0.00 0.00 0.00
Maximum of Months 244.00 194.57 65.51 373.87 152.43 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: TWINDOW1 W SWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 66.67 41.57 25.10 90.55 92.91 0.00 0.00 0.00
February 53.58 25.86 27.72 58.50 86.79 0.00 0.00 0.00
March 71.48 34.25 37.22 93.40 76.01 0.00 0.00 0.00
April 109.04 62.15 46.89 184.47 40.85 0.00 0.00 0.00
May 109.52 61.30 48.22 199.20 26.90 0.00 0.00 0.00
June 116.40 68.52 47.87 243.89 9.50 0.00 0.00 0.00
July 84.66 39.52 45.14 185.11 6.62 0.00 0.00 0.00
August 80.88 40.64 40.25 172.50 9.18 0.00 0.00 0.00
September 70.45 29.64 40.81 141.43 14.07 0.00 0.00 0.00
October 71.98 41.13 30.84 113.72 54.81 0.00 0.00 0.00
November 66.05 39.78 26.28 87.66 84.57 0.00 0.00 0.00
December 53.41 30.39 23.02 64.38 108.92 0.00 0.00 0.00
                 
Annual Sum or Average 79.60 42.96 36.64 136.56 50.78 0.00 0.00 0.00
Minimum of Months 53.41 25.86 23.02 58.50 6.62 0.00 0.00 0.00
Maximum of Months 116.40 68.52 48.22 243.89 108.92 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: TWINDOW1 W NWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 66.67 41.57 25.10 99.84 84.37 0.00 0.00 0.00
February 53.58 25.86 27.72 65.11 79.79 0.00 0.00 0.00
March 71.48 34.25 37.22 98.90 72.82 0.00 0.00 0.00
April 109.04 62.15 46.89 189.88 39.94 0.00 0.00 0.00
May 109.52 61.30 48.22 204.35 26.41 0.00 0.00 0.00
June 116.40 68.52 47.87 249.42 9.31 0.00 0.00 0.00
July 84.66 39.52 45.14 190.27 6.40 0.00 0.00 0.00
August 80.88 40.64 40.25 179.00 8.68 0.00 0.00 0.00
September 70.45 29.64 40.81 147.82 13.40 0.00 0.00 0.00
October 71.98 41.13 30.84 120.99 51.77 0.00 0.00 0.00
November 66.05 39.78 26.28 95.89 77.31 0.00 0.00 0.00
December 53.41 30.39 23.02 72.78 99.22 0.00 0.00 0.00
                 
Annual Sum or Average 79.60 42.96 36.64 143.19 47.32 0.00 0.00 0.00
Minimum of Months 53.41 25.86 23.02 65.11 6.40 0.00 0.00 0.00
Maximum of Months 116.40 68.52 48.22 249.42 99.22 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: TWINDOW1 N NWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 29.81 0.00 29.81 24.27 130.76 0.00 0.00 0.00
February 33.96 0.00 33.96 17.80 124.77 0.00 0.00 0.00
March 45.15 0.01 45.14 42.91 114.75 0.00 0.00 0.00
April 55.17 0.73 54.44 91.44 59.91 0.00 0.00 0.00
May 64.98 5.63 59.35 128.57 36.71 0.00 0.00 0.00
June 74.53 13.34 61.19 201.63 12.75 0.00 0.00 0.00
July 63.60 6.45 57.15 175.25 9.07 0.00 0.00 0.00
August 51.66 1.38 50.27 143.46 12.76 0.00 0.00 0.00
September 48.61 0.03 48.58 118.88 20.45 0.00 0.00 0.00
October 37.59 0.00 37.59 56.27 80.47 0.00 0.00 0.00
November 31.32 0.00 31.32 24.23 120.19 0.00 0.00 0.00
December 27.84 0.00 27.84 15.73 153.98 0.00 0.00 0.00
                 
Annual Sum or Average 47.07 2.30 44.76 87.02 72.84 0.00 0.00 0.00
Minimum of Months 27.84 0.00 27.84 15.73 9.07 0.00 0.00 0.00
Maximum of Months 74.53 13.34 61.19 201.63 153.98 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: TWINDOW1 S SEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 244.00 194.57 49.43 371.64 129.99 0.00 0.00 0.00
February 157.28 106.75 50.53 213.55 124.16 0.00 0.00 0.00
March 123.66 61.05 62.61 178.26 115.73 0.00 0.00 0.00
April 114.25 48.73 65.51 209.40 62.56 0.00 0.00 0.00
May 73.79 12.30 61.49 147.32 40.82 0.00 0.00 0.00
June 63.39 5.18 58.21 173.21 13.78 0.00 0.00 0.00
July 64.37 6.59 57.78 172.03 9.56 0.00 0.00 0.00
August 78.89 22.17 56.71 196.60 13.37 0.00 0.00 0.00
September 113.16 48.41 64.75 238.00 20.55 0.00 0.00 0.00
October 179.97 124.58 55.39 299.87 78.41 0.00 0.00 0.00
November 212.09 163.00 49.09 317.42 118.46 0.00 0.00 0.00
December 227.87 180.33 47.54 333.99 151.84 0.00 0.00 0.00
                 
Annual Sum or Average 137.70 81.09 56.61 237.84 73.06 0.00 0.00 0.00
Minimum of Months 63.39 5.18 47.54 147.32 9.56 0.00 0.00 0.00
Maximum of Months 244.00 194.57 65.51 371.64 151.84 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: TWINDOW1 E SEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 63.64 40.03 23.61 77.09 87.50 0.00 0.00 0.00
February 62.52 35.77 26.75 69.20 84.28 0.00 0.00 0.00
March 77.97 40.00 37.97 99.92 72.91 0.00 0.00 0.00
April 111.66 66.61 45.05 183.57 37.54 0.00 0.00 0.00
May 115.71 68.62 47.08 204.50 23.91 0.00 0.00 0.00
June 120.57 74.94 45.62 248.44 8.02 0.00 0.00 0.00
July 101.97 57.59 44.38 214.14 5.70 0.00 0.00 0.00
August 96.66 55.18 41.48 198.36 8.23 0.00 0.00 0.00
September 79.25 38.19 41.06 154.71 12.75 0.00 0.00 0.00
October 79.52 48.36 31.16 121.95 51.58 0.00 0.00 0.00
November 61.24 36.75 24.49 73.75 80.40 0.00 0.00 0.00
December 55.77 33.67 22.10 61.03 104.00 0.00 0.00 0.00
                 
Annual Sum or Average 85.65 49.71 35.94 142.57 47.92 0.00 0.00 0.00
Minimum of Months 55.77 33.67 22.10 61.03 5.70 0.00 0.00 0.00
Maximum of Months 120.57 74.94 47.08 248.44 104.00 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: TWINDOW1 E NEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 63.64 40.03 23.61 86.19 77.75 0.00 0.00 0.00
February 62.52 35.77 26.75 74.95 75.86 0.00 0.00 0.00
March 77.97 40.00 37.97 105.01 69.07 0.00 0.00 0.00
April 111.66 66.61 45.05 188.95 36.53 0.00 0.00 0.00
May 115.71 68.62 47.08 209.95 23.36 0.00 0.00 0.00
June 120.57 74.94 45.62 254.30 7.80 0.00 0.00 0.00
July 101.97 57.59 44.38 219.59 5.47 0.00 0.00 0.00
August 96.66 55.18 41.48 205.14 7.72 0.00 0.00 0.00
September 79.25 38.19 41.06 161.30 12.09 0.00 0.00 0.00
October 79.52 48.36 31.16 128.97 48.37 0.00 0.00 0.00
November 61.24 36.75 24.49 81.32 71.78 0.00 0.00 0.00
December 55.77 33.67 22.10 68.09 92.01 0.00 0.00 0.00
                 
Annual Sum or Average 85.65 49.71 35.94 149.00 43.85 0.00 0.00 0.00
Minimum of Months 55.77 33.67 22.10 68.09 5.47 0.00 0.00 0.00
Maximum of Months 120.57 74.94 47.08 254.30 92.01 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: TWINDOW1 N NEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 29.81 0.00 29.81 22.55 128.87 0.00 0.00 0.00
February 33.96 0.00 33.96 15.91 124.49 0.00 0.00 0.00
March 45.15 0.01 45.14 40.41 113.75 0.00 0.00 0.00
April 55.17 0.73 54.44 89.15 59.40 0.00 0.00 0.00
May 64.98 5.63 59.35 126.79 36.28 0.00 0.00 0.00
June 74.53 13.34 61.19 200.86 12.56 0.00 0.00 0.00
July 63.60 6.45 57.15 174.36 8.97 0.00 0.00 0.00
August 51.66 1.38 50.27 142.57 12.68 0.00 0.00 0.00
September 48.61 0.03 48.58 118.13 20.39 0.00 0.00 0.00
October 37.59 0.00 37.59 54.18 80.33 0.00 0.00 0.00
November 31.32 0.00 31.32 22.78 118.06 0.00 0.00 0.00
December 27.84 0.00 27.84 14.55 152.75 0.00 0.00 0.00
                 
Annual Sum or Average 47.07 2.30 44.76 85.51 72.17 0.00 0.00 0.00
Minimum of Months 27.84 0.00 27.84 14.55 8.97 0.00 0.00 0.00
Maximum of Months 74.53 13.34 61.19 200.86 152.75 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: TWINDOW1 N N1A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 29.81 0.00 29.81 24.00 132.87 0.00 0.00 0.00
February 33.96 0.00 33.96 17.22 128.75 0.00 0.00 0.00
March 45.15 0.01 45.14 42.56 116.81 0.00 0.00 0.00
April 55.17 0.73 54.44 93.27 59.83 0.00 0.00 0.00
May 64.98 5.63 59.35 130.92 36.35 0.00 0.00 0.00
June 74.53 13.34 61.19 205.64 12.42 0.00 0.00 0.00
July 63.60 6.45 57.15 178.54 8.86 0.00 0.00 0.00
August 51.66 1.38 50.27 146.45 12.56 0.00 0.00 0.00
September 48.61 0.03 48.58 121.16 20.32 0.00 0.00 0.00
October 37.59 0.00 37.59 56.87 81.65 0.00 0.00 0.00
November 31.32 0.00 31.32 24.01 121.90 0.00 0.00 0.00
December 27.84 0.00 27.84 15.42 156.26 0.00 0.00 0.00
                 
Annual Sum or Average 47.07 2.30 44.76 88.33 73.82 0.00 0.00 0.00
Minimum of Months 27.84 0.00 27.84 15.42 8.86 0.00 0.00 0.00
Maximum of Months 74.53 13.34 61.19 205.64 156.26 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: TWINDOW1 N N2A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 29.81 0.00 29.81 23.85 132.70 0.00 0.00 0.00
February 33.96 0.00 33.96 17.03 128.82 0.00 0.00 0.00
March 45.15 0.01 45.14 42.33 116.78 0.00 0.00 0.00
April 55.17 0.73 54.44 93.10 59.79 0.00 0.00 0.00
May 64.98 5.63 59.35 130.81 36.33 0.00 0.00 0.00
June 74.53 13.34 61.19 205.61 12.41 0.00 0.00 0.00
July 63.60 6.45 57.15 178.50 8.86 0.00 0.00 0.00
August 51.66 1.38 50.27 146.41 12.55 0.00 0.00 0.00
September 48.61 0.03 48.58 121.12 20.32 0.00 0.00 0.00
October 37.59 0.00 37.59 56.69 81.80 0.00 0.00 0.00
November 31.32 0.00 31.32 23.90 121.63 0.00 0.00 0.00
December 27.84 0.00 27.84 15.31 156.17 0.00 0.00 0.00
                 
Annual Sum or Average 47.07 2.30 44.76 88.22 73.79 0.00 0.00 0.00
Minimum of Months 27.84 0.00 27.84 15.31 8.86 0.00 0.00 0.00
Maximum of Months 74.53 13.34 61.19 205.61 156.17 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: TWINDOW1 S S1A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 244.00 194.57 49.43 371.65 134.84 0.00 0.00 0.00
February 157.28 106.75 50.53 213.93 130.12 0.00 0.00 0.00
March 123.66 61.05 62.61 179.82 119.52 0.00 0.00 0.00
April 114.25 48.73 65.51 213.38 63.03 0.00 0.00 0.00
May 73.79 12.30 61.49 151.81 40.78 0.00 0.00 0.00
June 63.39 5.18 58.21 178.58 13.58 0.00 0.00 0.00
July 64.37 6.59 57.78 176.58 9.43 0.00 0.00 0.00
August 78.89 22.17 56.71 200.75 13.23 0.00 0.00 0.00
September 113.16 48.41 64.75 241.00 20.52 0.00 0.00 0.00
October 179.97 124.58 55.39 301.91 80.29 0.00 0.00 0.00
November 212.09 163.00 49.09 317.54 122.77 0.00 0.00 0.00
December 227.87 180.33 47.54 333.60 157.46 0.00 0.00 0.00
                 
Annual Sum or Average 137.70 81.09 56.61 240.29 75.24 0.00 0.00 0.00
Minimum of Months 63.39 5.18 47.54 151.81 9.43 0.00 0.00 0.00
Maximum of Months 244.00 194.57 65.51 371.65 157.46 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: TWINDOW1 S S2A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 244.00 194.57 49.43 371.51 134.79 0.00 0.00 0.00
February 157.28 106.75 50.53 213.68 130.19 0.00 0.00 0.00
March 123.66 61.05 62.61 179.58 119.53 0.00 0.00 0.00
April 114.25 48.73 65.51 213.19 63.02 0.00 0.00 0.00
May 73.79 12.30 61.49 151.65 40.77 0.00 0.00 0.00
June 63.39 5.18 58.21 178.49 13.58 0.00 0.00 0.00
July 64.37 6.59 57.78 176.50 9.43 0.00 0.00 0.00
August 78.89 22.17 56.71 200.67 13.23 0.00 0.00 0.00
September 113.16 48.41 64.75 240.93 20.52 0.00 0.00 0.00
October 179.97 124.58 55.39 301.75 80.29 0.00 0.00 0.00
November 212.09 163.00 49.09 317.42 122.70 0.00 0.00 0.00
December 227.87 180.33 47.54 333.43 157.46 0.00 0.00 0.00
                 
Annual Sum or Average 137.70 81.09 56.61 240.14 75.23 0.00 0.00 0.00
Minimum of Months 63.39 5.18 47.54 151.65 9.43 0.00 0.00 0.00
Maximum of Months 244.00 194.57 65.51 371.51 157.46 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: TWINDOW14

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 15.27 9.61 5.67 19.34 21.98 412.00 0.00 0.00
February 15.00 8.58 6.42 16.98 21.50 455.50 0.00 0.00
March 18.71 9.60 9.11 24.08 19.08 396.83 0.00 0.00
April 26.79 15.98 10.81 43.74 10.39 300.17 0.00 0.00
May 27.76 16.47 11.30 48.44 6.95 270.83 0.00 0.00
June 28.93 17.98 10.95 57.99 2.69 170.50 0.00 0.00
July 24.47 13.82 10.65 49.54 2.11 166.83 0.00 0.00
August 23.19 13.24 9.95 46.31 2.95 228.67 0.00 0.00
September 19.02 9.16 9.85 36.15 4.22 272.33 0.00 0.00
October 19.08 11.60 7.48 29.39 13.70 357.50 0.00 0.00
November 14.70 8.82 5.88 18.23 20.44 435.33 0.00 0.00
December 13.38 8.08 5.30 15.27 25.47 467.17 0.00 0.00
                 
Annual Sum or Average 20.55 11.93 8.62 33.87 12.59 3933.67 0.00 0.00
Minimum of Months 13.38 8.08 5.30 15.27 2.11 166.83 0.00 0.00
Maximum of Months 28.93 17.98 11.30 57.99 25.47 467.17 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: ENTRANCE DOOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 45.48 28.61 16.87 56.08 67.51 1.67 0.00 0.00
February 44.68 25.56 19.12 50.74 64.70 2.17 0.00 0.00
March 55.72 28.59 27.14 72.22 55.89 0.00 0.00 0.00
April 79.80 47.60 32.20 129.22 33.32 0.00 0.00 0.00
May 82.69 49.04 33.65 141.66 23.98 0.00 0.00 0.00
June 86.16 53.56 32.60 167.10 10.99 0.00 0.00 0.00
July 72.87 41.16 31.72 141.54 9.18 8.17 0.00 0.00
August 69.08 39.43 29.65 132.70 12.51 4.83 0.00 0.00
September 56.63 27.29 29.34 103.25 17.10 5.50 0.00 0.00
October 56.83 34.56 22.27 84.32 45.72 0.00 0.00 0.00
November 43.77 26.27 17.50 51.83 65.75 6.33 0.00 0.00
December 39.86 24.06 15.80 42.59 82.12 0.00 0.00 0.00
                 
Annual Sum or Average 61.21 35.52 25.68 97.99 40.63 28.67 0.00 0.00
Minimum of Months 39.86 24.06 15.80 42.59 9.18 0.00 0.00 0.00
Maximum of Months 86.16 53.56 33.65 167.10 82.12 8.17 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: MWINDOW14

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 15.27 9.61 5.67 17.79 24.29 531.33 0.00 0.00
February 15.00 8.58 6.42 15.55 24.92 569.17 0.00 0.00
March 18.71 9.60 9.11 22.59 20.96 501.17 0.00 0.00
April 26.79 15.98 10.81 43.58 10.89 337.33 0.00 0.00
May 27.76 16.47 11.30 48.60 7.29 299.50 0.00 0.00
June 28.93 17.98 10.95 58.87 2.81 168.50 0.00 0.00
July 24.47 13.82 10.65 50.48 2.16 162.50 0.00 0.00
August 23.19 13.24 9.95 47.11 3.04 223.33 0.00 0.00
September 19.02 9.16 9.85 36.70 4.38 272.00 0.00 0.00
October 19.08 11.60 7.48 28.82 14.75 423.00 0.00 0.00
November 14.70 8.82 5.88 16.95 22.64 537.33 0.00 0.00
December 13.38 8.08 5.30 13.51 29.09 609.50 0.00 0.00
                 
Annual Sum or Average 20.55 11.93 8.62 33.46 13.89 4634.67 0.00 0.00
Minimum of Months 13.38 8.08 5.30 13.51 2.16 162.50 0.00 0.00
Maximum of Months 28.93 17.98 11.30 58.87 29.09 609.50 0.00 0.00



Table of Contents

Report: WindowEnergyReportMonthly

For: GWINDOW1 S SWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.653529E+09 0.521139E+09 0.132390E+09 0.100436E+10 0.373937E+09
February 0.380497E+09 0.258253E+09 0.122244E+09 0.528777E+09 0.319223E+09
March 0.331207E+09 0.163506E+09 0.167701E+09 0.497430E+09 0.315949E+09
April 0.296125E+09 0.126312E+09 0.169812E+09 0.565323E+09 0.168900E+09
May 0.197635E+09 32952456.36 0.164682E+09 0.416739E+09 0.115272E+09
June 0.164307E+09 13427492.44 0.150879E+09 0.467357E+09 39982777.97
July 0.172417E+09 17647504.23 0.154769E+09 0.473708E+09 30266811.64
August 0.211292E+09 59390576.21 0.151901E+09 0.538689E+09 43297480.87
September 0.293304E+09 0.125469E+09 0.167835E+09 0.625674E+09 65214643.83
October 0.482030E+09 0.333667E+09 0.148363E+09 0.811768E+09 0.232560E+09
November 0.549741E+09 0.422508E+09 0.127233E+09 0.824501E+09 0.339544E+09
December 0.610316E+09 0.482989E+09 0.127327E+09 0.888827E+09 0.453937E+09
           
Annual Sum or Average 0.434240E+10 0.255726E+10 0.178514E+10 0.764315E+10 0.249808E+10
Minimum of Months 0.164307E+09 13427492.44 0.122244E+09 0.416739E+09 30266811.64
Maximum of Months 0.653529E+09 0.521139E+09 0.169812E+09 0.100436E+10 0.453937E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: GWINDOW1 W SWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.178570E+09 0.111345E+09 67224900.11 0.248247E+09 0.269608E+09
February 0.129630E+09 62568269.37 67061855.43 0.147862E+09 0.225852E+09
March 0.191442E+09 91740267.11 99702139.57 0.260795E+09 0.209154E+09
April 0.282638E+09 0.161104E+09 0.121534E+09 0.490183E+09 0.110046E+09
May 0.293337E+09 0.164195E+09 0.129142E+09 0.546607E+09 75616214.01
June 0.301706E+09 0.177616E+09 0.124090E+09 0.644695E+09 27048880.73
July 0.226749E+09 0.105858E+09 0.120890E+09 0.503713E+09 20527963.59
August 0.216639E+09 0.108846E+09 0.107793E+09 0.468789E+09 29226062.36
September 0.182609E+09 76819089.91 0.105790E+09 0.370782E+09 44009953.58
October 0.192784E+09 0.110170E+09 82613685.71 0.308261E+09 0.163752E+09
November 0.171212E+09 0.103098E+09 68114413.41 0.229506E+09 0.243948E+09
December 0.143058E+09 81405036.02 61653233.84 0.172600E+09 0.330853E+09
           
Annual Sum or Average 0.251037E+10 0.135476E+10 0.115561E+10 0.439204E+10 0.174964E+10
Minimum of Months 0.129630E+09 62568269.37 61653233.84 0.147862E+09 20527963.59
Maximum of Months 0.301706E+09 0.177616E+09 0.129142E+09 0.644695E+09 0.330853E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: GWINDOW1 W NWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.178570E+09 0.111345E+09 67224900.11 0.265800E+09 0.243782E+09
February 0.129630E+09 62568269.37 67061855.43 0.159651E+09 0.202083E+09
March 0.191442E+09 91740267.11 99702139.57 0.273985E+09 0.193672E+09
April 0.282638E+09 0.161104E+09 0.121534E+09 0.501801E+09 0.105058E+09
May 0.293337E+09 0.164195E+09 0.129142E+09 0.557524E+09 72971082.93
June 0.301706E+09 0.177616E+09 0.124090E+09 0.656549E+09 25826047.81
July 0.226749E+09 0.105858E+09 0.120890E+09 0.515454E+09 19205142.24
August 0.216639E+09 0.108846E+09 0.107793E+09 0.483454E+09 26422476.80
September 0.182609E+09 76819089.91 0.105790E+09 0.384667E+09 40159706.62
October 0.192784E+09 0.110170E+09 82613685.71 0.320878E+09 0.156381E+09
November 0.171212E+09 0.103098E+09 68114413.41 0.241272E+09 0.231402E+09
December 0.143058E+09 81405036.02 61653233.84 0.186268E+09 0.304146E+09
           
Annual Sum or Average 0.251037E+10 0.135476E+10 0.115561E+10 0.454730E+10 0.162111E+10
Minimum of Months 0.129630E+09 62568269.37 61653233.84 0.159651E+09 19205142.24
Maximum of Months 0.301706E+09 0.177616E+09 0.129142E+09 0.656549E+09 0.304146E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: GWINDOW1 N NWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 79833222.32 0.00 79833222.32 59060223.18 0.376463E+09
February 82164655.87 0.00 82164655.87 43798934.00 0.314987E+09
March 0.120929E+09 13678.22 0.120915E+09 0.123046E+09 0.302442E+09
April 0.143009E+09 1893895.70 0.141116E+09 0.246931E+09 0.157012E+09
May 0.174031E+09 15072597.96 0.158958E+09 0.355188E+09 0.100267E+09
June 0.193172E+09 34569125.85 0.158603E+09 0.534197E+09 34878712.68
July 0.170349E+09 17270585.85 0.153079E+09 0.475818E+09 26969396.21
August 0.138358E+09 3709336.69 0.134649E+09 0.387976E+09 38555837.05
September 0.125999E+09 74957.01 0.125924E+09 0.308184E+09 61184387.01
October 0.100680E+09 0.00 0.100680E+09 0.143550E+09 0.242918E+09
November 81179262.24 0.00 81179262.24 50573506.53 0.359993E+09
December 74571601.52 0.00 74571601.52 30016846.13 0.473754E+09
           
Annual Sum or Average 0.148428E+10 72604177.28 0.141167E+10 0.275834E+10 0.248943E+10
Minimum of Months 74571601.52 0.00 74571601.52 30016846.13 26969396.21
Maximum of Months 0.193172E+09 34569125.85 0.158958E+09 0.534197E+09 0.473754E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: GWINDOW1 S SEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.653529E+09 0.521139E+09 0.132390E+09 0.101112E+10 0.380791E+09
February 0.380497E+09 0.258253E+09 0.122244E+09 0.533051E+09 0.318113E+09
March 0.331207E+09 0.163506E+09 0.167701E+09 0.497331E+09 0.321501E+09
April 0.296125E+09 0.126312E+09 0.169812E+09 0.551220E+09 0.204785E+09
May 0.197635E+09 32952456.36 0.164682E+09 0.395319E+09 0.158579E+09
June 0.164307E+09 13427492.44 0.150879E+09 0.423006E+09 76981054.36
July 0.172417E+09 17647504.23 0.154769E+09 0.416152E+09 70575897.28
August 0.211292E+09 59390576.21 0.151901E+09 0.501895E+09 89986239.92
September 0.293304E+09 0.125469E+09 0.167835E+09 0.595244E+09 0.118731E+09
October 0.482030E+09 0.333667E+09 0.148363E+09 0.800285E+09 0.276737E+09
November 0.549741E+09 0.422508E+09 0.127233E+09 0.830511E+09 0.357243E+09
December 0.610316E+09 0.482989E+09 0.127327E+09 0.895362E+09 0.456745E+09
           
Annual Sum or Average 0.434240E+10 0.255726E+10 0.178514E+10 0.745050E+10 0.283077E+10
Minimum of Months 0.164307E+09 13427492.44 0.122244E+09 0.395319E+09 70575897.28
Maximum of Months 0.653529E+09 0.521139E+09 0.169812E+09 0.101112E+10 0.456745E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: GWINDOW1 E SEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.170462E+09 0.107228E+09 63233663.96 0.211055E+09 0.253096E+09
February 0.151259E+09 86534717.39 64724083.33 0.173510E+09 0.212414E+09
March 0.208847E+09 0.107140E+09 0.101707E+09 0.277933E+09 0.201048E+09
April 0.289417E+09 0.172643E+09 0.116775E+09 0.479694E+09 0.122664E+09
May 0.309908E+09 0.183796E+09 0.126111E+09 0.547695E+09 92879358.51
June 0.312507E+09 0.194252E+09 0.118255E+09 0.627663E+09 45088581.13
July 0.273125E+09 0.154253E+09 0.118872E+09 0.543898E+09 42417644.39
August 0.258893E+09 0.147782E+09 0.111111E+09 0.515037E+09 55764179.40
September 0.205407E+09 98979348.38 0.106428E+09 0.384831E+09 73904112.74
October 0.212986E+09 0.129526E+09 83460598.94 0.321709E+09 0.180575E+09
November 0.158745E+09 95268428.64 63476343.40 0.191494E+09 0.239517E+09
December 0.149374E+09 90171447.43 59202954.34 0.158124E+09 0.307958E+09
           
Annual Sum or Average 0.270093E+10 0.156757E+10 0.113336E+10 0.443264E+10 0.182733E+10
Minimum of Months 0.149374E+09 86534717.39 59202954.34 0.158124E+09 42417644.39
Maximum of Months 0.312507E+09 0.194252E+09 0.126111E+09 0.627663E+09 0.307958E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: GWINDOW1 E NEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.170462E+09 0.107228E+09 63233663.96 0.225870E+09 0.222899E+09
February 0.151259E+09 86534717.39 64724083.33 0.182028E+09 0.191557E+09
March 0.208847E+09 0.107140E+09 0.101707E+09 0.288923E+09 0.182307E+09
April 0.289417E+09 0.172643E+09 0.116775E+09 0.499811E+09 95565737.00
May 0.309908E+09 0.183796E+09 0.126111E+09 0.573012E+09 64268776.76
June 0.312507E+09 0.194252E+09 0.118255E+09 0.669573E+09 21751180.59
July 0.273125E+09 0.154253E+09 0.118872E+09 0.594563E+09 16636711.19
August 0.258893E+09 0.147782E+09 0.111111E+09 0.554219E+09 23866710.23
September 0.205407E+09 98979348.38 0.106428E+09 0.419699E+09 36475825.47
October 0.212986E+09 0.129526E+09 83460598.94 0.341038E+09 0.144315E+09
November 0.158745E+09 95268428.64 63476343.40 0.199472E+09 0.213982E+09
December 0.149374E+09 90171447.43 59202954.34 0.168820E+09 0.281135E+09
           
Annual Sum or Average 0.270093E+10 0.156757E+10 0.113336E+10 0.471703E+10 0.149476E+10
Minimum of Months 0.149374E+09 86534717.39 59202954.34 0.168820E+09 16636711.19
Maximum of Months 0.312507E+09 0.194252E+09 0.126111E+09 0.669573E+09 0.281135E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: GWINDOW1 N NEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 79833222.32 0.00 79833222.32 57706027.35 0.374683E+09
February 82164655.87 0.00 82164655.87 41606879.03 0.317233E+09
March 0.120929E+09 13678.22 0.120915E+09 0.119878E+09 0.303411E+09
April 0.143009E+09 1893895.70 0.141116E+09 0.244142E+09 0.156688E+09
May 0.174031E+09 15072597.96 0.158958E+09 0.352521E+09 99849922.84
June 0.193172E+09 34569125.85 0.158603E+09 0.532871E+09 34560533.41
July 0.170349E+09 17270585.85 0.153079E+09 0.473967E+09 26903232.99
August 0.138358E+09 3709336.69 0.134649E+09 0.386246E+09 38622822.17
September 0.125999E+09 74957.01 0.125924E+09 0.306992E+09 61207075.78
October 0.100680E+09 0.00 0.100680E+09 0.141438E+09 0.242873E+09
November 81179262.24 0.00 81179262.24 49666282.27 0.357944E+09
December 74571601.52 0.00 74571601.52 28869841.61 0.474190E+09
           
Annual Sum or Average 0.148428E+10 72604177.28 0.141167E+10 0.273591E+10 0.248817E+10
Minimum of Months 74571601.52 0.00 74571601.52 28869841.61 26903232.99
Maximum of Months 0.193172E+09 34569125.85 0.158958E+09 0.532871E+09 0.474190E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: GWINDOW1 N N1A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 79833222.32 0.00 79833222.32 56822338.90 0.385379E+09
February 82164655.87 0.00 82164655.87 39180643.53 0.335891E+09
March 0.120929E+09 13678.22 0.120915E+09 0.117374E+09 0.316919E+09
April 0.143009E+09 1893895.70 0.141116E+09 0.249191E+09 0.156702E+09
May 0.174031E+09 15072597.96 0.158958E+09 0.358329E+09 99548956.16
June 0.193172E+09 34569125.85 0.158603E+09 0.541420E+09 33788857.18
July 0.170349E+09 17270585.85 0.153079E+09 0.483185E+09 25783001.93
August 0.138358E+09 3709336.69 0.134649E+09 0.395123E+09 36858900.56
September 0.125999E+09 74957.01 0.125924E+09 0.314117E+09 58840818.39
October 0.100680E+09 0.00 0.100680E+09 0.146230E+09 0.240876E+09
November 81179262.24 0.00 81179262.24 51088447.48 0.360320E+09
December 74571601.52 0.00 74571601.52 28136267.75 0.487079E+09
           
Annual Sum or Average 0.148428E+10 72604177.28 0.141167E+10 0.278020E+10 0.253799E+10
Minimum of Months 74571601.52 0.00 74571601.52 28136267.75 25783001.93
Maximum of Months 0.193172E+09 34569125.85 0.158958E+09 0.541420E+09 0.487079E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: GWINDOW1 N N2A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 79833222.32 0.00 79833222.32 56774749.16 0.385216E+09
February 82164655.87 0.00 82164655.87 38974620.37 0.336368E+09
March 0.120929E+09 13678.22 0.120915E+09 0.117103E+09 0.317249E+09
April 0.143009E+09 1893895.70 0.141116E+09 0.249026E+09 0.156744E+09
May 0.174031E+09 15072597.96 0.158958E+09 0.358201E+09 99558753.94
June 0.193172E+09 34569125.85 0.158603E+09 0.541364E+09 33783098.66
July 0.170349E+09 17270585.85 0.153079E+09 0.483107E+09 25786585.14
August 0.138358E+09 3709336.69 0.134649E+09 0.395046E+09 36872270.74
September 0.125999E+09 74957.01 0.125924E+09 0.314061E+09 58850379.60
October 0.100680E+09 0.00 0.100680E+09 0.146087E+09 0.240961E+09
November 81179262.24 0.00 81179262.24 51054732.68 0.360170E+09
December 74571601.52 0.00 74571601.52 28049539.07 0.487241E+09
           
Annual Sum or Average 0.148428E+10 72604177.28 0.141167E+10 0.277885E+10 0.253880E+10
Minimum of Months 74571601.52 0.00 74571601.52 28049539.07 25786585.14
Maximum of Months 0.193172E+09 34569125.85 0.158958E+09 0.541364E+09 0.487241E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: GWINDOW1 S S1A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.653529E+09 0.521139E+09 0.132390E+09 0.100101E+10 0.378981E+09
February 0.380497E+09 0.258253E+09 0.122244E+09 0.521957E+09 0.333675E+09
March 0.331207E+09 0.163506E+09 0.167701E+09 0.490611E+09 0.327638E+09
April 0.296125E+09 0.126312E+09 0.169812E+09 0.566738E+09 0.169144E+09
May 0.197635E+09 32952456.36 0.164682E+09 0.419750E+09 0.114988E+09
June 0.164307E+09 13427492.44 0.150879E+09 0.474579E+09 38926514.58
July 0.172417E+09 17647504.23 0.154769E+09 0.480965E+09 29080074.03
August 0.211292E+09 59390576.21 0.151901E+09 0.545470E+09 41601894.93
September 0.293304E+09 0.125469E+09 0.167835E+09 0.630973E+09 63030357.54
October 0.482030E+09 0.333667E+09 0.148363E+09 0.813322E+09 0.231973E+09
November 0.549741E+09 0.422508E+09 0.127233E+09 0.823927E+09 0.341102E+09
December 0.610316E+09 0.482989E+09 0.127327E+09 0.884935E+09 0.460126E+09
           
Annual Sum or Average 0.434240E+10 0.255726E+10 0.178514E+10 0.765424E+10 0.253027E+10
Minimum of Months 0.164307E+09 13427492.44 0.122244E+09 0.419750E+09 29080074.03
Maximum of Months 0.653529E+09 0.521139E+09 0.169812E+09 0.100101E+10 0.460126E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: GWINDOW1 S S2A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.653529E+09 0.521139E+09 0.132390E+09 0.100112E+10 0.378752E+09
February 0.380497E+09 0.258253E+09 0.122244E+09 0.522072E+09 0.333268E+09
March 0.331207E+09 0.163506E+09 0.167701E+09 0.490358E+09 0.327657E+09
April 0.296125E+09 0.126312E+09 0.169812E+09 0.565525E+09 0.170447E+09
May 0.197635E+09 32952456.36 0.164682E+09 0.417821E+09 0.116603E+09
June 0.164307E+09 13427492.44 0.150879E+09 0.471907E+09 40101677.05
July 0.172417E+09 17647504.23 0.154769E+09 0.477900E+09 30226313.95
August 0.211292E+09 59390576.21 0.151901E+09 0.543092E+09 43062235.74
September 0.293304E+09 0.125469E+09 0.167835E+09 0.628961E+09 64890904.53
October 0.482030E+09 0.333667E+09 0.148363E+09 0.812058E+09 0.233534E+09
November 0.549741E+09 0.422508E+09 0.127233E+09 0.823700E+09 0.341493E+09
December 0.610316E+09 0.482989E+09 0.127327E+09 0.885070E+09 0.459838E+09
           
Annual Sum or Average 0.434240E+10 0.255726E+10 0.178514E+10 0.763958E+10 0.253987E+10
Minimum of Months 0.164307E+09 13427492.44 0.122244E+09 0.417821E+09 30226313.95
Maximum of Months 0.653529E+09 0.521139E+09 0.169812E+09 0.100112E+10 0.459838E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: MWINDOW1 S SWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.653529E+09 0.521139E+09 0.132390E+09 0.993946E+09 0.381031E+09
February 0.380497E+09 0.258253E+09 0.122244E+09 0.512589E+09 0.342553E+09
March 0.331207E+09 0.163506E+09 0.167701E+09 0.476508E+09 0.342275E+09
April 0.296125E+09 0.126312E+09 0.169812E+09 0.557631E+09 0.172562E+09
May 0.197635E+09 32952456.36 0.164682E+09 0.410688E+09 0.117018E+09
June 0.164307E+09 13427492.44 0.150879E+09 0.467248E+09 39031454.12
July 0.172417E+09 17647504.23 0.154769E+09 0.479021E+09 27686971.92
August 0.211292E+09 59390576.21 0.151901E+09 0.544243E+09 38731093.15
September 0.293304E+09 0.125469E+09 0.167835E+09 0.631463E+09 57619492.18
October 0.482030E+09 0.333667E+09 0.148363E+09 0.812315E+09 0.226260E+09
November 0.549741E+09 0.422508E+09 0.127233E+09 0.821959E+09 0.336300E+09
December 0.610316E+09 0.482989E+09 0.127327E+09 0.884334E+09 0.454160E+09
           
Annual Sum or Average 0.434240E+10 0.255726E+10 0.178514E+10 0.759194E+10 0.253523E+10
Minimum of Months 0.164307E+09 13427492.44 0.122244E+09 0.410688E+09 27686971.92
Maximum of Months 0.653529E+09 0.521139E+09 0.169812E+09 0.993946E+09 0.454160E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: MWINDOW1 W SWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.178570E+09 0.111345E+09 67224900.11 0.243956E+09 0.274818E+09
February 0.129630E+09 62568269.37 67061855.43 0.139942E+09 0.242870E+09
March 0.191442E+09 91740267.11 99702139.57 0.247603E+09 0.226265E+09
April 0.282638E+09 0.161104E+09 0.121534E+09 0.484710E+09 0.112462E+09
May 0.293337E+09 0.164195E+09 0.129142E+09 0.541418E+09 76844223.83
June 0.301706E+09 0.177616E+09 0.124090E+09 0.643093E+09 26579390.71
July 0.226749E+09 0.105858E+09 0.120890E+09 0.506354E+09 18970917.84
August 0.216639E+09 0.108846E+09 0.107793E+09 0.472054E+09 26425187.91
September 0.182609E+09 76819089.91 0.105790E+09 0.374832E+09 39237701.42
October 0.192784E+09 0.110170E+09 82613685.71 0.309216E+09 0.159263E+09
November 0.171212E+09 0.103098E+09 68114413.41 0.228645E+09 0.241395E+09
December 0.143058E+09 81405036.02 61653233.84 0.170912E+09 0.330697E+09
           
Annual Sum or Average 0.251037E+10 0.135476E+10 0.115561E+10 0.436274E+10 0.177583E+10
Minimum of Months 0.129630E+09 62568269.37 61653233.84 0.139942E+09 18970917.84
Maximum of Months 0.301706E+09 0.177616E+09 0.129142E+09 0.643093E+09 0.330697E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: MWINDOW1 W NWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.178570E+09 0.111345E+09 67224900.11 0.259740E+09 0.256530E+09
February 0.129630E+09 62568269.37 67061855.43 0.149407E+09 0.230005E+09
March 0.191442E+09 91740267.11 99702139.57 0.257938E+09 0.218648E+09
April 0.282638E+09 0.161104E+09 0.121534E+09 0.496531E+09 0.108805E+09
May 0.293337E+09 0.164195E+09 0.129142E+09 0.553805E+09 74371957.81
June 0.301706E+09 0.177616E+09 0.124090E+09 0.656449E+09 25431512.01
July 0.226749E+09 0.105858E+09 0.120890E+09 0.518957E+09 17847458.55
August 0.216639E+09 0.108846E+09 0.107793E+09 0.487633E+09 24128457.42
September 0.182609E+09 76819089.91 0.105790E+09 0.389356E+09 36184935.31
October 0.192784E+09 0.110170E+09 82613685.71 0.323165E+09 0.152203E+09
November 0.171212E+09 0.103098E+09 68114413.41 0.242114E+09 0.227447E+09
December 0.143058E+09 81405036.02 61653233.84 0.186329E+09 0.302013E+09
           
Annual Sum or Average 0.251037E+10 0.135476E+10 0.115561E+10 0.452142E+10 0.167362E+10
Minimum of Months 0.129630E+09 62568269.37 61653233.84 0.149407E+09 17847458.55
Maximum of Months 0.301706E+09 0.177616E+09 0.129142E+09 0.656449E+09 0.302013E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: MWINDOW1 N NWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 79833222.32 0.00 79833222.32 52812062.53 0.396571E+09
February 82164655.87 0.00 82164655.87 32141349.76 0.359562E+09
March 0.120929E+09 13678.22 0.120915E+09 0.103862E+09 0.343165E+09
April 0.143009E+09 1893895.70 0.141116E+09 0.241700E+09 0.162719E+09
May 0.174031E+09 15072597.96 0.158958E+09 0.351318E+09 0.102017E+09
June 0.193172E+09 34569125.85 0.158603E+09 0.535875E+09 34297924.87
July 0.170349E+09 17270585.85 0.153079E+09 0.482498E+09 25005716.92
August 0.138358E+09 3709336.69 0.134649E+09 0.395772E+09 35153101.72
September 0.125999E+09 74957.01 0.125924E+09 0.316832E+09 55087766.10
October 0.100680E+09 0.00 0.100680E+09 0.148571E+09 0.235923E+09
November 81179262.24 0.00 81179262.24 53102012.03 0.353013E+09
December 74571601.52 0.00 74571601.52 31050105.17 0.469577E+09
           
Annual Sum or Average 0.148428E+10 72604177.28 0.141167E+10 0.274553E+10 0.257209E+10
Minimum of Months 74571601.52 0.00 74571601.52 31050105.17 25005716.92
Maximum of Months 0.193172E+09 34569125.85 0.158958E+09 0.535875E+09 0.469577E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: MWINDOW1 S SEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.653529E+09 0.521139E+09 0.132390E+09 0.991507E+09 0.379875E+09
February 0.380497E+09 0.258253E+09 0.122244E+09 0.509579E+09 0.343009E+09
March 0.331207E+09 0.163506E+09 0.167701E+09 0.472568E+09 0.341917E+09
April 0.296125E+09 0.126312E+09 0.169812E+09 0.553622E+09 0.172415E+09
May 0.197635E+09 32952456.36 0.164682E+09 0.406784E+09 0.117147E+09
June 0.164307E+09 13427492.44 0.150879E+09 0.464568E+09 38961455.94
July 0.172417E+09 17647504.23 0.154769E+09 0.476201E+09 27744480.21
August 0.211292E+09 59390576.21 0.151901E+09 0.541512E+09 38949064.76
September 0.293304E+09 0.125469E+09 0.167835E+09 0.629563E+09 57667405.74
October 0.482030E+09 0.333667E+09 0.148363E+09 0.808907E+09 0.226004E+09
November 0.549741E+09 0.422508E+09 0.127233E+09 0.820093E+09 0.334866E+09
December 0.610316E+09 0.482989E+09 0.127327E+09 0.881630E+09 0.453835E+09
           
Annual Sum or Average 0.434240E+10 0.255726E+10 0.178514E+10 0.755653E+10 0.253239E+10
Minimum of Months 0.164307E+09 13427492.44 0.122244E+09 0.406784E+09 27744480.21
Maximum of Months 0.653529E+09 0.521139E+09 0.169812E+09 0.991507E+09 0.453835E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: MWINDOW1 E SEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.170462E+09 0.107228E+09 63233663.96 0.201824E+09 0.253554E+09
February 0.151259E+09 86534717.39 64724083.33 0.161432E+09 0.230990E+09
March 0.208847E+09 0.107140E+09 0.101707E+09 0.261196E+09 0.213274E+09
April 0.289417E+09 0.172643E+09 0.116775E+09 0.481503E+09 0.102448E+09
May 0.309908E+09 0.183796E+09 0.126111E+09 0.555109E+09 67775535.08
June 0.312507E+09 0.194252E+09 0.118255E+09 0.654726E+09 22395334.25
July 0.273125E+09 0.154253E+09 0.118872E+09 0.584258E+09 16402708.65
August 0.258893E+09 0.147782E+09 0.111111E+09 0.541524E+09 23832032.64
September 0.205407E+09 98979348.38 0.106428E+09 0.409239E+09 35561264.37
October 0.212986E+09 0.129526E+09 83460598.94 0.329011E+09 0.147559E+09
November 0.158745E+09 95268428.64 63476343.40 0.187623E+09 0.225345E+09
December 0.149374E+09 90171447.43 59202954.34 0.153816E+09 0.308848E+09
           
Annual Sum or Average 0.270093E+10 0.156757E+10 0.113336E+10 0.452126E+10 0.164799E+10
Minimum of Months 0.149374E+09 86534717.39 59202954.34 0.153816E+09 16402708.65
Maximum of Months 0.312507E+09 0.194252E+09 0.126111E+09 0.654726E+09 0.308848E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: MWINDOW1 E NEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.170462E+09 0.107228E+09 63233663.96 0.218259E+09 0.234390E+09
February 0.151259E+09 86534717.39 64724083.33 0.170274E+09 0.217201E+09
March 0.208847E+09 0.107140E+09 0.101707E+09 0.271389E+09 0.205223E+09
April 0.289417E+09 0.172643E+09 0.116775E+09 0.493699E+09 98707867.69
May 0.309908E+09 0.183796E+09 0.126111E+09 0.568539E+09 65276701.87
June 0.312507E+09 0.194252E+09 0.118255E+09 0.669132E+09 21239468.79
July 0.273125E+09 0.154253E+09 0.118872E+09 0.597816E+09 15268402.99
August 0.258893E+09 0.147782E+09 0.111111E+09 0.558075E+09 21517749.62
September 0.205407E+09 98979348.38 0.106428E+09 0.424498E+09 32649822.70
October 0.212986E+09 0.129526E+09 83460598.94 0.343201E+09 0.140336E+09
November 0.158745E+09 95268428.64 63476343.40 0.200401E+09 0.210305E+09
December 0.149374E+09 90171447.43 59202954.34 0.168769E+09 0.279688E+09
           
Annual Sum or Average 0.270093E+10 0.156757E+10 0.113336E+10 0.468405E+10 0.154180E+10
Minimum of Months 0.149374E+09 86534717.39 59202954.34 0.168769E+09 15268402.99
Maximum of Months 0.312507E+09 0.194252E+09 0.126111E+09 0.669132E+09 0.279688E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: MWINDOW1 N NEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 79833222.32 0.00 79833222.32 51252191.47 0.394051E+09
February 82164655.87 0.00 82164655.87 30446481.39 0.360632E+09
March 0.120929E+09 13678.22 0.120915E+09 0.100973E+09 0.342894E+09
April 0.143009E+09 1893895.70 0.141116E+09 0.238501E+09 0.162230E+09
May 0.174031E+09 15072597.96 0.158958E+09 0.348314E+09 0.101477E+09
June 0.193172E+09 34569125.85 0.158603E+09 0.534487E+09 33934728.00
July 0.170349E+09 17270585.85 0.153079E+09 0.480733E+09 24876938.39
August 0.138358E+09 3709336.69 0.134649E+09 0.394034E+09 35121531.82
September 0.125999E+09 74957.01 0.125924E+09 0.315490E+09 55061466.52
October 0.100680E+09 0.00 0.100680E+09 0.145941E+09 0.235858E+09
November 81179262.24 0.00 81179262.24 51852105.36 0.350875E+09
December 74571601.52 0.00 74571601.52 29544827.62 0.470226E+09
           
Annual Sum or Average 0.148428E+10 72604177.28 0.141167E+10 0.272157E+10 0.256724E+10
Minimum of Months 74571601.52 0.00 74571601.52 29544827.62 24876938.39
Maximum of Months 0.193172E+09 34569125.85 0.158958E+09 0.534487E+09 0.470226E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: MWINDOW1 N N1A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 79833222.32 0.00 79833222.32 51446019.86 0.402490E+09
February 82164655.87 0.00 82164655.87 30407842.08 0.369680E+09
March 0.120929E+09 13678.22 0.120915E+09 0.102924E+09 0.347100E+09
April 0.143009E+09 1893895.70 0.141116E+09 0.245664E+09 0.160638E+09
May 0.174031E+09 15072597.96 0.158958E+09 0.356548E+09 0.100207E+09
June 0.193172E+09 34569125.85 0.158603E+09 0.544392E+09 32948799.33
July 0.170349E+09 17270585.85 0.153079E+09 0.489731E+09 24036000.56
August 0.138358E+09 3709336.69 0.134649E+09 0.402266E+09 34016221.65
September 0.125999E+09 74957.01 0.125924E+09 0.321466E+09 53953382.91
October 0.100680E+09 0.00 0.100680E+09 0.150275E+09 0.235311E+09
November 81179262.24 0.00 81179262.24 52431231.86 0.357255E+09
December 74571601.52 0.00 74571601.52 27918443.11 0.488964E+09
           
Annual Sum or Average 0.148428E+10 72604177.28 0.141167E+10 0.277547E+10 0.260660E+10
Minimum of Months 74571601.52 0.00 74571601.52 27918443.11 24036000.56
Maximum of Months 0.193172E+09 34569125.85 0.158958E+09 0.544392E+09 0.488964E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: MWINDOW1 N N2A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 79833222.32 0.00 79833222.32 51371839.38 0.402335E+09
February 82164655.87 0.00 82164655.87 30302313.68 0.369819E+09
March 0.120929E+09 13678.22 0.120915E+09 0.102748E+09 0.347187E+09
April 0.143009E+09 1893895.70 0.141116E+09 0.245495E+09 0.160649E+09
May 0.174031E+09 15072597.96 0.158958E+09 0.356417E+09 0.100207E+09
June 0.193172E+09 34569125.85 0.158603E+09 0.544338E+09 32938812.50
July 0.170349E+09 17270585.85 0.153079E+09 0.489664E+09 24035312.94
August 0.138358E+09 3709336.69 0.134649E+09 0.402196E+09 34022440.39
September 0.125999E+09 74957.01 0.125924E+09 0.321406E+09 53957753.56
October 0.100680E+09 0.00 0.100680E+09 0.150133E+09 0.235364E+09
November 81179262.24 0.00 81179262.24 52367553.90 0.357148E+09
December 74571601.52 0.00 74571601.52 27802731.29 0.489185E+09
           
Annual Sum or Average 0.148428E+10 72604177.28 0.141167E+10 0.277424E+10 0.260685E+10
Minimum of Months 74571601.52 0.00 74571601.52 27802731.29 24035312.94
Maximum of Months 0.193172E+09 34569125.85 0.158958E+09 0.544338E+09 0.489185E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: MWINDOW1 S S1A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.653529E+09 0.521139E+09 0.132390E+09 0.992043E+09 0.384271E+09
February 0.380497E+09 0.258253E+09 0.122244E+09 0.509975E+09 0.347924E+09
March 0.331207E+09 0.163506E+09 0.167701E+09 0.475103E+09 0.345036E+09
April 0.296125E+09 0.126312E+09 0.169812E+09 0.561093E+09 0.170979E+09
May 0.197635E+09 32952456.36 0.164682E+09 0.416245E+09 0.115191E+09
June 0.164307E+09 13427492.44 0.150879E+09 0.476458E+09 37546149.94
July 0.172417E+09 17647504.23 0.154769E+09 0.486815E+09 26653957.67
August 0.211292E+09 59390576.21 0.151901E+09 0.550905E+09 37577549.31
September 0.293304E+09 0.125469E+09 0.167835E+09 0.635812E+09 56568053.11
October 0.482030E+09 0.333667E+09 0.148363E+09 0.812955E+09 0.226759E+09
November 0.549741E+09 0.422508E+09 0.127233E+09 0.820658E+09 0.338775E+09
December 0.610316E+09 0.482989E+09 0.127327E+09 0.879518E+09 0.461613E+09
           
Annual Sum or Average 0.434240E+10 0.255726E+10 0.178514E+10 0.761758E+10 0.254889E+10
Minimum of Months 0.164307E+09 13427492.44 0.122244E+09 0.416245E+09 26653957.67
Maximum of Months 0.653529E+09 0.521139E+09 0.169812E+09 0.992043E+09 0.461613E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: MWINDOW1 S S2A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.653529E+09 0.521139E+09 0.132390E+09 0.991944E+09 0.384249E+09
February 0.380497E+09 0.258253E+09 0.122244E+09 0.509817E+09 0.348015E+09
March 0.331207E+09 0.163506E+09 0.167701E+09 0.474858E+09 0.345144E+09
April 0.296125E+09 0.126312E+09 0.169812E+09 0.560860E+09 0.171022E+09
May 0.197635E+09 32952456.36 0.164682E+09 0.415989E+09 0.115233E+09
June 0.164307E+09 13427492.44 0.150879E+09 0.476278E+09 37554260.98
July 0.172417E+09 17647504.23 0.154769E+09 0.486648E+09 26665924.81
August 0.211292E+09 59390576.21 0.151901E+09 0.550744E+09 37602905.78
September 0.293304E+09 0.125469E+09 0.167835E+09 0.635707E+09 56584336.53
October 0.482030E+09 0.333667E+09 0.148363E+09 0.812791E+09 0.226800E+09
November 0.549741E+09 0.422508E+09 0.127233E+09 0.820584E+09 0.338733E+09
December 0.610316E+09 0.482989E+09 0.127327E+09 0.879391E+09 0.461650E+09
           
Annual Sum or Average 0.434240E+10 0.255726E+10 0.178514E+10 0.761561E+10 0.254925E+10
Minimum of Months 0.164307E+09 13427492.44 0.122244E+09 0.415989E+09 26665924.81
Maximum of Months 0.653529E+09 0.521139E+09 0.169812E+09 0.991944E+09 0.461650E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: TWINDOW1 S SWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.653529E+09 0.521139E+09 0.132390E+09 0.100137E+10 0.350898E+09
February 0.380497E+09 0.258253E+09 0.122244E+09 0.523347E+09 0.300679E+09
March 0.331207E+09 0.163506E+09 0.167701E+09 0.485118E+09 0.311978E+09
April 0.296125E+09 0.126312E+09 0.169812E+09 0.549262E+09 0.163154E+09
May 0.197635E+09 32952456.36 0.164682E+09 0.400152E+09 0.109715E+09
June 0.164307E+09 13427492.44 0.150879E+09 0.452213E+09 35934643.57
July 0.172417E+09 17647504.23 0.154769E+09 0.464082E+09 25718728.92
August 0.211292E+09 59390576.21 0.151901E+09 0.529935E+09 35852545.92
September 0.293304E+09 0.125469E+09 0.167835E+09 0.619416E+09 53428814.59
October 0.482030E+09 0.333667E+09 0.148363E+09 0.809260E+09 0.211211E+09
November 0.549741E+09 0.422508E+09 0.127233E+09 0.827417E+09 0.310007E+09
December 0.610316E+09 0.482989E+09 0.127327E+09 0.900551E+09 0.408259E+09
           
Annual Sum or Average 0.434240E+10 0.255726E+10 0.178514E+10 0.756212E+10 0.231684E+10
Minimum of Months 0.164307E+09 13427492.44 0.122244E+09 0.400152E+09 25718728.92
Maximum of Months 0.653529E+09 0.521139E+09 0.169812E+09 0.100137E+10 0.408259E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: TWINDOW1 W SWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.178570E+09 0.111345E+09 67224900.11 0.242530E+09 0.248837E+09
February 0.129630E+09 62568269.37 67061855.43 0.141520E+09 0.209953E+09
March 0.191442E+09 91740267.11 99702139.57 0.250152E+09 0.203575E+09
April 0.282638E+09 0.161104E+09 0.121534E+09 0.478134E+09 0.105878E+09
May 0.293337E+09 0.164195E+09 0.129142E+09 0.533537E+09 72042776.59
June 0.301706E+09 0.177616E+09 0.124090E+09 0.632162E+09 24623351.38
July 0.226749E+09 0.105858E+09 0.120890E+09 0.495789E+09 17719952.68
August 0.216639E+09 0.108846E+09 0.107793E+09 0.462013E+09 24576451.49
September 0.182609E+09 76819089.91 0.105790E+09 0.366583E+09 36473200.12
October 0.192784E+09 0.110170E+09 82613685.71 0.304577E+09 0.146800E+09
November 0.171212E+09 0.103098E+09 68114413.41 0.227219E+09 0.219213E+09
December 0.143058E+09 81405036.02 61653233.84 0.172427E+09 0.291737E+09
           
Annual Sum or Average 0.251037E+10 0.135476E+10 0.115561E+10 0.430665E+10 0.160143E+10
Minimum of Months 0.129630E+09 62568269.37 61653233.84 0.141520E+09 17719952.68
Maximum of Months 0.301706E+09 0.177616E+09 0.129142E+09 0.632162E+09 0.291737E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: TWINDOW1 W NWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.178570E+09 0.111345E+09 67224900.11 0.267410E+09 0.225982E+09
February 0.129630E+09 62568269.37 67061855.43 0.157521E+09 0.193024E+09
March 0.191442E+09 91740267.11 99702139.57 0.264906E+09 0.195042E+09
April 0.282638E+09 0.161104E+09 0.121534E+09 0.492179E+09 0.103527E+09
May 0.293337E+09 0.164195E+09 0.129142E+09 0.547325E+09 70747473.38
June 0.301706E+09 0.177616E+09 0.124090E+09 0.646490E+09 24138118.63
July 0.226749E+09 0.105858E+09 0.120890E+09 0.509614E+09 17145418.03
August 0.216639E+09 0.108846E+09 0.107793E+09 0.479432E+09 23245916.34
September 0.182609E+09 76819089.91 0.105790E+09 0.383156E+09 34736811.48
October 0.192784E+09 0.110170E+09 82613685.71 0.324056E+09 0.138672E+09
November 0.171212E+09 0.103098E+09 68114413.41 0.248544E+09 0.200399E+09
December 0.143058E+09 81405036.02 61653233.84 0.194946E+09 0.265748E+09
           
Annual Sum or Average 0.251037E+10 0.135476E+10 0.115561E+10 0.451558E+10 0.149241E+10
Minimum of Months 0.129630E+09 62568269.37 61653233.84 0.157521E+09 17145418.03
Maximum of Months 0.301706E+09 0.177616E+09 0.129142E+09 0.646490E+09 0.265748E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: TWINDOW1 N NWA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 79833222.32 0.00 79833222.32 64998749.95 0.350231E+09
February 82164655.87 0.00 82164655.87 43073251.56 0.301833E+09
March 0.120929E+09 13678.22 0.120915E+09 0.114936E+09 0.307334E+09
April 0.143009E+09 1893895.70 0.141116E+09 0.237003E+09 0.155297E+09
May 0.174031E+09 15072597.96 0.158958E+09 0.344353E+09 98313148.34
June 0.193172E+09 34569125.85 0.158603E+09 0.522617E+09 33043751.81
July 0.170349E+09 17270585.85 0.153079E+09 0.469402E+09 24297121.27
August 0.138358E+09 3709336.69 0.134649E+09 0.384255E+09 34180481.24
September 0.125999E+09 74957.01 0.125924E+09 0.308130E+09 53016905.04
October 0.100680E+09 0.00 0.100680E+09 0.150704E+09 0.215541E+09
November 81179262.24 0.00 81179262.24 62793292.83 0.311536E+09
December 74571601.52 0.00 74571601.52 42135417.89 0.412428E+09
           
Annual Sum or Average 0.148428E+10 72604177.28 0.141167E+10 0.274440E+10 0.229705E+10
Minimum of Months 74571601.52 0.00 74571601.52 42135417.89 24297121.27
Maximum of Months 0.193172E+09 34569125.85 0.158958E+09 0.522617E+09 0.412428E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: TWINDOW1 S SEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.653529E+09 0.521139E+09 0.132390E+09 0.995391E+09 0.348169E+09
February 0.380497E+09 0.258253E+09 0.122244E+09 0.516620E+09 0.300378E+09
March 0.331207E+09 0.163506E+09 0.167701E+09 0.477444E+09 0.309966E+09
April 0.296125E+09 0.126312E+09 0.169812E+09 0.542753E+09 0.162154E+09
May 0.197635E+09 32952456.36 0.164682E+09 0.394584E+09 0.109329E+09
June 0.164307E+09 13427492.44 0.150879E+09 0.448972E+09 35720514.20
July 0.172417E+09 17647504.23 0.154769E+09 0.460752E+09 25611519.62
August 0.211292E+09 59390576.21 0.151901E+09 0.526573E+09 35819791.57
September 0.293304E+09 0.125469E+09 0.167835E+09 0.616894E+09 53266579.61
October 0.482030E+09 0.333667E+09 0.148363E+09 0.803178E+09 0.210018E+09
November 0.549741E+09 0.422508E+09 0.127233E+09 0.822755E+09 0.307053E+09
December 0.610316E+09 0.482989E+09 0.127327E+09 0.894546E+09 0.406681E+09
           
Annual Sum or Average 0.434240E+10 0.255726E+10 0.178514E+10 0.750046E+10 0.230417E+10
Minimum of Months 0.164307E+09 13427492.44 0.122244E+09 0.394584E+09 25611519.62
Maximum of Months 0.653529E+09 0.521139E+09 0.169812E+09 0.995391E+09 0.406681E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: TWINDOW1 E SEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.170462E+09 0.107228E+09 63233663.96 0.206479E+09 0.234367E+09
February 0.151259E+09 86534717.39 64724083.33 0.167406E+09 0.203899E+09
March 0.208847E+09 0.107140E+09 0.101707E+09 0.267617E+09 0.195271E+09
April 0.289417E+09 0.172643E+09 0.116775E+09 0.475815E+09 97309900.32
May 0.309908E+09 0.183796E+09 0.126111E+09 0.547734E+09 64042524.03
June 0.312507E+09 0.194252E+09 0.118255E+09 0.643955E+09 20790931.75
July 0.273125E+09 0.154253E+09 0.118872E+09 0.573558E+09 15257630.64
August 0.258893E+09 0.147782E+09 0.111111E+09 0.531279E+09 22045736.75
September 0.205407E+09 98979348.38 0.106428E+09 0.401002E+09 33046130.37
October 0.212986E+09 0.129526E+09 83460598.94 0.326636E+09 0.138148E+09
November 0.158745E+09 95268428.64 63476343.40 0.191153E+09 0.208388E+09
December 0.149374E+09 90171447.43 59202954.34 0.163453E+09 0.278559E+09
           
Annual Sum or Average 0.270093E+10 0.156757E+10 0.113336E+10 0.449609E+10 0.151112E+10
Minimum of Months 0.149374E+09 86534717.39 59202954.34 0.163453E+09 15257630.64
Maximum of Months 0.312507E+09 0.194252E+09 0.126111E+09 0.643955E+09 0.278559E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: TWINDOW1 E NEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.170462E+09 0.107228E+09 63233663.96 0.230853E+09 0.208243E+09
February 0.151259E+09 86534717.39 64724083.33 0.181326E+09 0.183514E+09
March 0.208847E+09 0.107140E+09 0.101707E+09 0.281264E+09 0.185001E+09
April 0.289417E+09 0.172643E+09 0.116775E+09 0.489748E+09 94689017.06
May 0.309908E+09 0.183796E+09 0.126111E+09 0.562322E+09 62576087.60
June 0.312507E+09 0.194252E+09 0.118255E+09 0.659138E+09 20218662.73
July 0.273125E+09 0.154253E+09 0.118872E+09 0.588149E+09 14642594.63
August 0.258893E+09 0.147782E+09 0.111111E+09 0.549459E+09 20667569.43
September 0.205407E+09 98979348.38 0.106428E+09 0.418087E+09 31339947.20
October 0.212986E+09 0.129526E+09 83460598.94 0.345431E+09 0.129542E+09
November 0.158745E+09 95268428.64 63476343.40 0.210792E+09 0.186061E+09
December 0.149374E+09 90171447.43 59202954.34 0.182367E+09 0.246433E+09
           
Annual Sum or Average 0.270093E+10 0.156757E+10 0.113336E+10 0.469894E+10 0.138293E+10
Minimum of Months 0.149374E+09 86534717.39 59202954.34 0.181326E+09 14642594.63
Maximum of Months 0.312507E+09 0.194252E+09 0.126111E+09 0.659138E+09 0.246433E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: TWINDOW1 N NEA

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 79833222.32 0.00 79833222.32 60410997.93 0.345157E+09
February 82164655.87 0.00 82164655.87 38485964.93 0.301157E+09
March 0.120929E+09 13678.22 0.120915E+09 0.108234E+09 0.304679E+09
April 0.143009E+09 1893895.70 0.141116E+09 0.231085E+09 0.153976E+09
May 0.174031E+09 15072597.96 0.158958E+09 0.339587E+09 97184421.40
June 0.193172E+09 34569125.85 0.158603E+09 0.520635E+09 32551824.37
July 0.170349E+09 17270585.85 0.153079E+09 0.467014E+09 24034325.95
August 0.138358E+09 3709336.69 0.134649E+09 0.381847E+09 33956062.05
September 0.125999E+09 74957.01 0.125924E+09 0.306205E+09 52854159.25
October 0.100680E+09 0.00 0.100680E+09 0.145113E+09 0.215162E+09
November 81179262.24 0.00 81179262.24 59050324.27 0.306003E+09
December 74571601.52 0.00 74571601.52 38969340.56 0.409132E+09
           
Annual Sum or Average 0.148428E+10 72604177.28 0.141167E+10 0.269664E+10 0.227585E+10
Minimum of Months 74571601.52 0.00 74571601.52 38485964.93 24034325.95
Maximum of Months 0.193172E+09 34569125.85 0.158958E+09 0.520635E+09 0.409132E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: TWINDOW1 N N1A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 79833222.32 0.00 79833222.32 64283482.03 0.355873E+09
February 82164655.87 0.00 82164655.87 41656278.67 0.311466E+09
March 0.120929E+09 13678.22 0.120915E+09 0.113980E+09 0.312857E+09
April 0.143009E+09 1893895.70 0.141116E+09 0.241765E+09 0.155070E+09
May 0.174031E+09 15072597.96 0.158958E+09 0.350647E+09 97361774.80
June 0.193172E+09 34569125.85 0.158603E+09 0.533029E+09 32187185.14
July 0.170349E+09 17270585.85 0.153079E+09 0.478192E+09 23738104.98
August 0.138358E+09 3709336.69 0.134649E+09 0.392257E+09 33628598.85
September 0.125999E+09 74957.01 0.125924E+09 0.314051E+09 52679703.37
October 0.100680E+09 0.00 0.100680E+09 0.152331E+09 0.218696E+09
November 81179262.24 0.00 81179262.24 62239628.07 0.315962E+09
December 74571601.52 0.00 74571601.52 41295912.55 0.418531E+09
           
Annual Sum or Average 0.148428E+10 72604177.28 0.141167E+10 0.278572E+10 0.232805E+10
Minimum of Months 74571601.52 0.00 74571601.52 41295912.55 23738104.98
Maximum of Months 0.193172E+09 34569125.85 0.158958E+09 0.533029E+09 0.418531E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: TWINDOW1 N N2A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 79833222.32 0.00 79833222.32 63871735.73 0.355418E+09
February 82164655.87 0.00 82164655.87 41191216.68 0.311639E+09
March 0.120929E+09 13678.22 0.120915E+09 0.113386E+09 0.312792E+09
April 0.143009E+09 1893895.70 0.141116E+09 0.241308E+09 0.154983E+09
May 0.174031E+09 15072597.96 0.158958E+09 0.350361E+09 97310769.74
June 0.193172E+09 34569125.85 0.158603E+09 0.532932E+09 32158378.26
July 0.170349E+09 17270585.85 0.153079E+09 0.478084E+09 23724270.76
August 0.138358E+09 3709336.69 0.134649E+09 0.392139E+09 33617658.71
September 0.125999E+09 74957.01 0.125924E+09 0.313937E+09 52665438.98
October 0.100680E+09 0.00 0.100680E+09 0.151826E+09 0.219088E+09
November 81179262.24 0.00 81179262.24 61936730.18 0.315254E+09
December 74571601.52 0.00 74571601.52 41010529.03 0.418288E+09
           
Annual Sum or Average 0.148428E+10 72604177.28 0.141167E+10 0.278198E+10 0.232694E+10
Minimum of Months 74571601.52 0.00 74571601.52 41010529.03 23724270.76
Maximum of Months 0.193172E+09 34569125.85 0.158958E+09 0.532932E+09 0.418288E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: TWINDOW1 S S1A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.653529E+09 0.521139E+09 0.132390E+09 0.995437E+09 0.361162E+09
February 0.380497E+09 0.258253E+09 0.122244E+09 0.517537E+09 0.314798E+09
March 0.331207E+09 0.163506E+09 0.167701E+09 0.481627E+09 0.320110E+09
April 0.296125E+09 0.126312E+09 0.169812E+09 0.553078E+09 0.163377E+09
May 0.197635E+09 32952456.36 0.164682E+09 0.406619E+09 0.109212E+09
June 0.164307E+09 13427492.44 0.150879E+09 0.462888E+09 35207714.38
July 0.172417E+09 17647504.23 0.154769E+09 0.472944E+09 25260459.27
August 0.211292E+09 59390576.21 0.151901E+09 0.537676E+09 35445075.25
September 0.293304E+09 0.125469E+09 0.167835E+09 0.624661E+09 53188832.02
October 0.482030E+09 0.333667E+09 0.148363E+09 0.808623E+09 0.215047E+09
November 0.549741E+09 0.422508E+09 0.127233E+09 0.823063E+09 0.318222E+09
December 0.610316E+09 0.482989E+09 0.127327E+09 0.893518E+09 0.421729E+09
           
Annual Sum or Average 0.434240E+10 0.255726E+10 0.178514E+10 0.757767E+10 0.237276E+10
Minimum of Months 0.164307E+09 13427492.44 0.122244E+09 0.406619E+09 25260459.27
Maximum of Months 0.653529E+09 0.521139E+09 0.169812E+09 0.995437E+09 0.421729E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: TWINDOW1 S S2A

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.653529E+09 0.521139E+09 0.132390E+09 0.995049E+09 0.361016E+09
February 0.380497E+09 0.258253E+09 0.122244E+09 0.516944E+09 0.314965E+09
March 0.331207E+09 0.163506E+09 0.167701E+09 0.480984E+09 0.320139E+09
April 0.296125E+09 0.126312E+09 0.169812E+09 0.552576E+09 0.163335E+09
May 0.197635E+09 32952456.36 0.164682E+09 0.406167E+09 0.109190E+09
June 0.164307E+09 13427492.44 0.150879E+09 0.462648E+09 35187640.30
July 0.172417E+09 17647504.23 0.154769E+09 0.472738E+09 25253220.33
August 0.211292E+09 59390576.21 0.151901E+09 0.537463E+09 35444732.12
September 0.293304E+09 0.125469E+09 0.167835E+09 0.624499E+09 53181286.33
October 0.482030E+09 0.333667E+09 0.148363E+09 0.808205E+09 0.215039E+09
November 0.549741E+09 0.422508E+09 0.127233E+09 0.822758E+09 0.318038E+09
December 0.610316E+09 0.482989E+09 0.127327E+09 0.893068E+09 0.421735E+09
           
Annual Sum or Average 0.434240E+10 0.255726E+10 0.178514E+10 0.757310E+10 0.237252E+10
Minimum of Months 0.164307E+09 13427492.44 0.122244E+09 0.406167E+09 25253220.33
Maximum of Months 0.653529E+09 0.521139E+09 0.169812E+09 0.995049E+09 0.421735E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: TWINDOW14

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 40903053.76 25729878.70 15173175.05 51796545.10 58884566.89
February 36295164.92 20764357.67 15530807.25 41072839.70 52023802.29
March 50113681.88 25708662.89 24405018.99 64502382.38 51098569.22
April 69446852.95 41426324.01 28020528.95 0.113379E+09 26943430.34
May 74363618.79 44102717.30 30260901.49 0.129747E+09 18604752.56
June 74987257.51 46611476.30 28375781.21 0.150315E+09 6966807.97
July 65537496.83 37013680.88 28523815.96 0.132694E+09 5652189.48
August 62122436.92 35460814.07 26661622.85 0.124034E+09 7896552.56
September 49288266.72 23750497.53 25537769.19 93712657.09 10927543.08
October 51106921.76 31080211.33 20026710.43 78705255.41 36699246.17
November 38091454.20 22860047.23 15231406.97 47240932.47 52975859.54
December 35842995.72 21637005.84 14205989.87 40888213.77 68218930.67
           
Annual Sum or Average 0.648099E+09 0.376146E+09 0.271954E+09 0.106809E+10 0.396892E+09
Minimum of Months 35842995.72 20764357.67 14205989.87 40888213.77 5652189.48
Maximum of Months 74987257.51 46611476.30 30260901.49 0.150315E+09 68218930.67



Table of Contents

Report: WindowEnergyReportMonthly

For: ENTRANCE DOOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.121819E+09 76629982.01 45189491.35 0.150200E+09 0.180806E+09
February 0.108096E+09 61841424.63 46254609.03 0.122754E+09 0.156513E+09
March 0.149251E+09 76566796.04 72684220.06 0.193445E+09 0.149691E+09
April 0.206830E+09 0.123378E+09 83452108.49 0.334938E+09 86363555.90
May 0.221473E+09 0.131349E+09 90124495.47 0.379427E+09 64215246.12
June 0.223331E+09 0.138821E+09 84510138.12 0.433121E+09 28482424.21
July 0.195187E+09 0.110236E+09 84951022.45 0.379092E+09 24591118.79
August 0.185016E+09 0.105611E+09 79404947.95 0.355411E+09 33498907.01
September 0.146793E+09 70734892.27 76057832.05 0.267620E+09 44319049.91
October 0.152209E+09 92564604.06 59644527.58 0.225855E+09 0.122458E+09
November 0.113446E+09 68082909.68 45362920.50 0.134343E+09 0.170432E+09
December 0.106749E+09 64440388.06 42308973.19 0.114085E+09 0.219946E+09
           
Annual Sum or Average 0.193020E+10 0.112026E+10 0.809945E+09 0.309029E+10 0.128132E+10
Minimum of Months 0.106749E+09 61841424.63 42308973.19 0.114085E+09 24591118.79
Maximum of Months 0.223331E+09 0.138821E+09 90124495.47 0.433121E+09 0.219946E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: MWINDOW14

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 40903053.76 25729878.70 15173175.05 47652697.20 65050350.78
February 36295164.92 20764357.67 15530807.25 37630289.01 60286793.65
March 50113681.88 25708662.89 24405018.99 60505957.62 56139983.81
April 69446852.95 41426324.01 28020528.95 0.112967E+09 28225898.52
May 74363618.79 44102717.30 30260901.49 0.130159E+09 19517383.60
June 74987257.51 46611476.30 28375781.21 0.152582E+09 7284246.27
July 65537496.83 37013680.88 28523815.96 0.135197E+09 5798692.31
August 62122436.92 35460814.07 26661622.85 0.126190E+09 8129972.00
September 49288266.72 23750497.53 25537769.19 95126843.93 11348184.49
October 51106921.76 31080211.33 20026710.43 77194958.52 39506615.36
November 38091454.20 22860047.23 15231406.97 43940625.48 58687731.37
December 35842995.72 21637005.84 14205989.87 36196285.56 77902891.26
           
Annual Sum or Average 0.648099E+09 0.376146E+09 0.271954E+09 0.105534E+10 0.437879E+09
Minimum of Months 35842995.72 20764357.67 14205989.87 36196285.56 5798692.31
Maximum of Months 74987257.51 46611476.30 30260901.49 0.152582E+09 77902891.26



Table of Contents

Report: WindowZoneSummaryMonthly

For: G SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 460.24 232.84 310.67 236.14 74.53 0.00 0.00
February 274.12 219.74 210.87 132.61 78.25 0.00 0.00
March 279.93 192.89 195.13 95.30 99.84 0.00 0.00
April 406.71 107.11 223.29 110.89 112.40 0.00 0.00
May 359.66 71.26 183.31 73.61 109.70 0.00 0.00
June 429.03 25.86 179.79 73.70 106.08 0.00 0.00
July 364.92 18.96 149.03 46.11 102.92 0.00 0.00
August 376.09 27.02 159.77 62.81 96.96 0.00 0.00
September 384.37 42.07 183.61 78.04 105.57 0.00 0.00
October 414.96 144.75 251.95 165.71 86.24 0.00 0.00
November 399.85 218.32 278.15 202.78 75.37 0.00 0.00
December 385.96 282.68 281.28 210.72 70.56 0.00 0.00
               
Annual Sum or Average 378.54 131.61 217.30 124.05 93.25 0.00 0.00
Minimum of Months 274.12 18.96 149.03 46.11 70.56 0.00 0.00
Maximum of Months 460.24 282.68 310.67 236.14 112.40 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: G NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 119.40 229.69 96.48 41.57 54.91 0.00 0.00
February 81.67 211.31 87.55 25.86 61.68 0.00 0.00
March 145.65 182.65 116.63 34.26 82.37 0.00 0.00
April 288.70 100.95 164.22 62.88 101.33 0.00 0.00
May 339.19 63.11 174.50 66.93 107.56 0.00 0.00
June 458.30 22.33 190.92 81.86 109.06 0.00 0.00
July 369.63 16.77 148.26 45.97 102.29 0.00 0.00
August 325.04 23.95 132.54 42.02 90.52 0.00 0.00
September 267.30 39.09 119.06 29.67 89.40 0.00 0.00
October 172.06 147.74 109.57 41.13 68.43 0.00 0.00
November 109.68 225.25 97.37 39.78 57.60 0.00 0.00
December 77.27 286.95 81.25 30.39 50.86 0.00 0.00
               
Annual Sum or Average 230.14 128.83 126.67 45.26 81.41 0.00 0.00
Minimum of Months 77.27 16.77 81.25 25.86 50.86 0.00 0.00
Maximum of Months 458.30 286.95 190.92 81.86 109.06 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: OFFICE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 453.89 234.24 307.64 234.61 73.04 0.00 0.00
February 289.33 216.56 219.81 142.52 77.29 0.00 0.00
March 284.64 190.28 201.63 101.05 100.59 0.00 0.00
April 390.81 119.41 225.90 115.34 110.57 0.00 0.00
May 346.36 88.16 189.49 80.92 108.57 0.00 0.00
June 402.02 43.77 183.96 80.12 103.83 0.00 0.00
July 356.50 40.25 166.35 64.18 102.17 0.00 0.00
August 377.73 52.47 175.55 77.35 98.20 0.00 0.00
September 376.16 72.36 192.40 86.59 105.81 0.00 0.00
October 416.38 168.22 259.49 172.94 86.55 0.00 0.00
November 391.35 227.29 273.34 199.76 73.58 0.00 0.00
December 389.70 281.88 283.64 213.99 69.64 0.00 0.00
               
Annual Sum or Average 373.40 144.30 223.34 130.80 92.54 0.00 0.00
Minimum of Months 284.64 40.25 166.35 64.18 69.64 0.00 0.00
Maximum of Months 453.89 281.88 307.64 234.61 110.57 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: G NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 93.92 211.16 93.45 40.03 53.42 0.00 0.00
February 82.08 199.95 96.49 35.77 60.72 0.00 0.00
March 144.73 173.45 123.12 40.01 83.12 0.00 0.00
April 282.47 92.77 166.83 67.34 99.49 0.00 0.00
May 345.15 60.87 180.68 74.25 106.43 0.00 0.00
June 463.90 21.71 195.09 88.28 106.81 0.00 0.00
July 398.87 16.18 165.57 64.04 101.53 0.00 0.00
August 350.95 23.15 148.32 56.56 91.76 0.00 0.00
September 278.98 36.31 127.86 38.22 89.64 0.00 0.00
October 172.41 136.83 117.11 48.36 68.75 0.00 0.00
November 84.18 208.71 92.56 36.75 55.81 0.00 0.00
December 58.36 266.56 83.61 33.67 49.95 0.00 0.00
               
Annual Sum or Average 230.36 120.32 132.71 52.01 80.70 0.00 0.00
Minimum of Months 58.36 16.18 83.61 33.67 49.95 0.00 0.00
Maximum of Months 463.90 266.56 195.09 88.28 106.81 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: G N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 21.22 143.88 29.81 0.00 29.81 0.00 0.00
February 16.20 138.84 33.96 0.00 33.96 0.00 0.00
March 43.82 118.32 45.15 0.01 45.14 0.00 0.00
April 96.14 60.46 55.17 0.73 54.44 0.00 0.00
May 133.78 37.17 64.98 5.63 59.35 0.00 0.00
June 208.88 13.04 74.53 13.34 61.19 0.00 0.00
July 180.40 9.63 63.60 6.45 57.15 0.00 0.00
August 147.52 13.76 51.66 1.38 50.27 0.00 0.00
September 121.19 22.70 48.61 0.03 48.58 0.00 0.00
October 54.60 89.93 37.59 0.00 37.59 0.00 0.00
November 19.71 139.01 31.32 0.00 31.32 0.00 0.00
December 10.50 181.85 27.84 0.00 27.84 0.00 0.00
               
Annual Sum or Average 88.16 80.48 47.07 2.30 44.76 0.00 0.00
Minimum of Months 10.50 9.63 27.84 0.00 27.84 0.00 0.00
Maximum of Months 208.88 181.85 74.53 13.34 61.19 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: G N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 21.20 143.82 29.81 0.00 29.81 0.00 0.00
February 16.11 139.04 33.96 0.00 33.96 0.00 0.00
March 43.72 118.45 45.15 0.01 45.14 0.00 0.00
April 96.07 60.47 55.17 0.73 54.44 0.00 0.00
May 133.74 37.17 64.98 5.63 59.35 0.00 0.00
June 208.86 13.03 74.53 13.34 61.19 0.00 0.00
July 180.37 9.63 63.60 6.45 57.15 0.00 0.00
August 147.49 13.77 51.66 1.38 50.27 0.00 0.00
September 121.17 22.70 48.61 0.03 48.58 0.00 0.00
October 54.54 89.96 37.59 0.00 37.59 0.00 0.00
November 19.70 138.95 31.32 0.00 31.32 0.00 0.00
December 10.47 181.91 27.84 0.00 27.84 0.00 0.00
               
Annual Sum or Average 88.12 80.50 47.07 2.30 44.76 0.00 0.00
Minimum of Months 10.47 9.63 27.84 0.00 27.84 0.00 0.00
Maximum of Months 208.86 181.91 74.53 13.34 61.19 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: G S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 373.73 141.50 244.00 194.57 49.43 0.00 0.00
February 215.76 137.93 157.28 106.75 50.53 0.00 0.00
March 183.17 122.33 123.66 61.05 62.61 0.00 0.00
April 218.65 65.26 114.25 48.73 65.51 0.00 0.00
May 156.72 42.93 73.79 12.30 61.49 0.00 0.00
June 183.09 15.02 63.39 5.18 58.21 0.00 0.00
July 179.57 10.86 64.37 6.59 57.78 0.00 0.00
August 203.66 15.53 78.89 22.17 56.71 0.00 0.00
September 243.43 24.32 113.16 48.41 64.75 0.00 0.00
October 303.66 86.61 179.97 124.58 55.39 0.00 0.00
November 317.87 131.60 212.09 163.00 49.09 0.00 0.00
December 330.40 171.79 227.87 180.33 47.54 0.00 0.00
               
Annual Sum or Average 242.71 80.23 137.70 81.09 56.61 0.00 0.00
Minimum of Months 156.72 10.86 63.39 5.18 47.54 0.00 0.00
Maximum of Months 373.73 171.79 244.00 194.57 65.51 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: G S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 373.78 141.41 244.00 194.57 49.43 0.00 0.00
February 215.80 137.76 157.28 106.75 50.53 0.00 0.00
March 183.08 122.33 123.66 61.05 62.61 0.00 0.00
April 218.18 65.76 114.25 48.73 65.51 0.00 0.00
May 156.00 43.53 73.79 12.30 61.49 0.00 0.00
June 182.06 15.47 63.39 5.18 58.21 0.00 0.00
July 178.43 11.29 64.37 6.59 57.78 0.00 0.00
August 202.77 16.08 78.89 22.17 56.71 0.00 0.00
September 242.65 25.04 113.16 48.41 64.75 0.00 0.00
October 303.19 87.19 179.97 124.58 55.39 0.00 0.00
November 317.79 131.75 212.09 163.00 49.09 0.00 0.00
December 330.45 171.68 227.87 180.33 47.54 0.00 0.00
               
Annual Sum or Average 242.25 80.54 137.70 81.09 56.61 0.00 0.00
Minimum of Months 156.00 11.29 63.39 5.18 47.54 0.00 0.00
Maximum of Months 373.78 171.68 244.00 194.57 65.51 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: M SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 454.52 237.20 310.67 236.14 74.53 0.00 0.00
February 263.50 235.76 210.87 132.61 78.25 0.00 0.00
March 266.52 208.43 195.13 95.30 99.84 0.00 0.00
April 401.57 109.39 223.29 110.89 112.40 0.00 0.00
May 355.47 72.37 183.31 73.61 109.70 0.00 0.00
June 428.36 25.31 179.79 73.70 106.08 0.00 0.00
July 367.89 17.41 149.03 46.11 102.92 0.00 0.00
August 379.38 24.26 159.77 62.81 96.96 0.00 0.00
September 388.17 37.31 183.61 78.04 105.57 0.00 0.00
October 415.66 140.86 251.95 165.71 86.24 0.00 0.00
November 398.66 216.21 278.15 202.78 75.37 0.00 0.00
December 383.69 282.74 281.28 210.72 70.56 0.00 0.00
               
Annual Sum or Average 375.88 133.51 217.30 124.05 93.25 0.00 0.00
Minimum of Months 263.50 17.41 149.03 46.11 70.56 0.00 0.00
Maximum of Months 454.52 282.74 310.67 236.14 112.40 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: M NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 114.41 241.56 96.48 41.57 54.91 0.00 0.00
February 71.85 240.51 87.55 25.86 61.68 0.00 0.00
March 131.59 206.27 116.63 34.26 82.37 0.00 0.00
April 284.62 104.57 164.22 62.88 101.33 0.00 0.00
May 336.33 64.25 174.50 66.93 107.56 0.00 0.00
June 458.90 21.94 190.92 81.86 109.06 0.00 0.00
July 373.47 15.56 148.26 45.97 102.29 0.00 0.00
August 329.53 21.84 132.54 42.02 90.52 0.00 0.00
September 272.44 35.21 119.06 29.67 89.40 0.00 0.00
October 174.88 143.66 109.57 41.13 68.43 0.00 0.00
November 111.14 221.19 97.37 39.78 57.60 0.00 0.00
December 77.80 284.72 81.25 30.39 50.86 0.00 0.00
               
Annual Sum or Average 228.78 132.97 126.67 45.26 81.41 0.00 0.00
Minimum of Months 71.85 15.56 81.25 25.86 50.86 0.00 0.00
Maximum of Months 458.90 284.72 190.92 81.86 109.06 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: M SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 442.69 233.65 307.64 234.61 73.04 0.00 0.00
February 273.52 233.42 219.81 142.52 77.29 0.00 0.00
March 268.63 201.95 201.63 101.05 100.59 0.00 0.00
April 392.88 99.57 225.90 115.34 110.57 0.00 0.00
May 354.24 64.16 189.49 80.92 108.57 0.00 0.00
June 429.79 21.64 183.96 80.12 103.83 0.00 0.00
July 395.03 15.58 166.35 64.18 102.17 0.00 0.00
August 403.40 22.48 175.55 77.35 98.20 0.00 0.00
September 399.59 34.79 192.40 86.59 105.81 0.00 0.00
October 422.69 137.32 259.49 172.94 86.55 0.00 0.00
November 385.78 213.13 273.34 199.76 73.58 0.00 0.00
December 382.03 280.19 283.64 213.99 69.64 0.00 0.00
               
Annual Sum or Average 379.81 129.38 223.34 130.80 92.54 0.00 0.00
Minimum of Months 268.63 15.58 166.35 64.18 69.64 0.00 0.00
Maximum of Months 442.69 280.19 307.64 234.61 110.57 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: M NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 87.87 221.88 93.45 40.03 53.42 0.00 0.00
February 70.75 226.64 96.49 35.77 60.72 0.00 0.00
March 129.84 195.46 123.12 40.01 83.12 0.00 0.00
April 277.56 95.74 166.83 67.34 99.49 0.00 0.00
May 341.88 61.83 180.68 74.25 106.43 0.00 0.00
June 464.34 21.27 195.09 88.28 106.81 0.00 0.00
July 402.61 14.92 165.57 64.04 101.53 0.00 0.00
August 355.33 21.00 148.32 56.56 91.76 0.00 0.00
September 284.30 32.65 127.86 38.22 89.64 0.00 0.00
October 175.15 132.98 117.11 48.36 68.75 0.00 0.00
November 85.63 204.82 92.56 36.75 55.81 0.00 0.00
December 58.81 264.75 83.61 33.67 49.95 0.00 0.00
               
Annual Sum or Average 228.58 124.05 132.71 52.01 80.70 0.00 0.00
Minimum of Months 58.81 14.92 83.61 33.67 49.95 0.00 0.00
Maximum of Months 464.34 264.75 195.09 88.28 106.81 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: M N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 19.21 150.27 29.81 0.00 29.81 0.00 0.00
February 12.57 152.81 33.96 0.00 33.96 0.00 0.00
March 38.43 129.59 45.15 0.01 45.14 0.00 0.00
April 94.78 61.97 55.17 0.73 54.44 0.00 0.00
May 133.12 37.41 64.98 5.63 59.35 0.00 0.00
June 210.03 12.71 74.53 13.34 61.19 0.00 0.00
July 182.84 8.97 63.60 6.45 57.15 0.00 0.00
August 150.19 12.70 51.66 1.38 50.27 0.00 0.00
September 124.02 20.82 48.61 0.03 48.58 0.00 0.00
October 56.11 87.85 37.59 0.00 37.59 0.00 0.00
November 20.23 137.83 31.32 0.00 31.32 0.00 0.00
December 10.42 182.56 27.84 0.00 27.84 0.00 0.00
               
Annual Sum or Average 88.01 82.65 47.07 2.30 44.76 0.00 0.00
Minimum of Months 10.42 8.97 27.84 0.00 27.84 0.00 0.00
Maximum of Months 210.03 182.56 74.53 13.34 61.19 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: M N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 19.18 150.21 29.81 0.00 29.81 0.00 0.00
February 12.53 152.87 33.96 0.00 33.96 0.00 0.00
March 38.36 129.62 45.15 0.01 45.14 0.00 0.00
April 94.71 61.98 55.17 0.73 54.44 0.00 0.00
May 133.07 37.41 64.98 5.63 59.35 0.00 0.00
June 210.01 12.71 74.53 13.34 61.19 0.00 0.00
July 182.82 8.97 63.60 6.45 57.15 0.00 0.00
August 150.16 12.70 51.66 1.38 50.27 0.00 0.00
September 124.00 20.82 48.61 0.03 48.58 0.00 0.00
October 56.05 87.87 37.59 0.00 37.59 0.00 0.00
November 20.20 137.79 31.32 0.00 31.32 0.00 0.00
December 10.38 182.64 27.84 0.00 27.84 0.00 0.00
               
Annual Sum or Average 87.97 82.66 47.07 2.30 44.76 0.00 0.00
Minimum of Months 10.38 8.97 27.84 0.00 27.84 0.00 0.00
Maximum of Months 210.01 182.64 74.53 13.34 61.19 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: M S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 370.39 143.47 244.00 194.57 49.43 0.00 0.00
February 210.80 143.82 157.28 106.75 50.53 0.00 0.00
March 177.38 128.82 123.66 61.05 62.61 0.00 0.00
April 216.47 65.96 114.25 48.73 65.51 0.00 0.00
May 155.41 43.01 73.79 12.30 61.49 0.00 0.00
June 183.82 14.49 63.39 5.18 58.21 0.00 0.00
July 181.76 9.95 64.37 6.59 57.78 0.00 0.00
August 205.68 14.03 78.89 22.17 56.71 0.00 0.00
September 245.30 21.82 113.16 48.41 64.75 0.00 0.00
October 303.52 84.66 179.97 124.58 55.39 0.00 0.00
November 316.61 130.70 212.09 163.00 49.09 0.00 0.00
December 328.37 172.35 227.87 180.33 47.54 0.00 0.00
               
Annual Sum or Average 241.55 80.82 137.70 81.09 56.61 0.00 0.00
Minimum of Months 155.41 9.95 63.39 5.18 47.54 0.00 0.00
Maximum of Months 370.39 172.35 244.00 194.57 65.51 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: M S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 370.35 143.46 244.00 194.57 49.43 0.00 0.00
February 210.74 143.86 157.28 106.75 50.53 0.00 0.00
March 177.29 128.86 123.66 61.05 62.61 0.00 0.00
April 216.38 65.98 114.25 48.73 65.51 0.00 0.00
May 155.31 43.02 73.79 12.30 61.49 0.00 0.00
June 183.75 14.49 63.39 5.18 58.21 0.00 0.00
July 181.69 9.96 64.37 6.59 57.78 0.00 0.00
August 205.62 14.04 78.89 22.17 56.71 0.00 0.00
September 245.26 21.83 113.16 48.41 64.75 0.00 0.00
October 303.46 84.68 179.97 124.58 55.39 0.00 0.00
November 316.58 130.68 212.09 163.00 49.09 0.00 0.00
December 328.33 172.36 227.87 180.33 47.54 0.00 0.00
               
Annual Sum or Average 241.49 80.84 137.70 81.09 56.61 0.00 0.00
Minimum of Months 155.31 9.96 63.39 5.18 47.54 0.00 0.00
Maximum of Months 370.35 172.36 244.00 194.57 65.51 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: T SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 458.42 217.92 310.67 236.14 74.53 0.00 0.00
February 270.12 206.36 210.87 132.61 78.25 0.00 0.00
March 271.10 189.06 195.13 95.30 99.84 0.00 0.00
April 395.75 103.17 223.29 110.89 112.40 0.00 0.00
May 348.59 67.85 183.31 73.61 109.70 0.00 0.00
June 418.34 23.35 179.79 73.70 106.08 0.00 0.00
July 358.37 16.21 149.03 46.11 102.92 0.00 0.00
August 370.29 22.50 159.77 62.81 96.96 0.00 0.00
September 380.35 34.63 183.61 78.04 105.57 0.00 0.00
October 413.41 131.22 251.95 165.71 86.24 0.00 0.00
November 401.47 198.77 278.15 202.78 75.37 0.00 0.00
December 392.75 253.49 281.28 210.72 70.56 0.00 0.00
               
Annual Sum or Average 373.81 121.70 217.30 124.05 93.25 0.00 0.00
Minimum of Months 270.12 16.21 149.03 46.11 70.56 0.00 0.00
Maximum of Months 458.42 253.49 310.67 236.14 112.40 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: T NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 121.94 212.96 96.48 41.57 54.91 0.00 0.00
February 80.23 201.87 87.55 25.86 61.68 0.00 0.00
March 138.39 184.14 116.63 34.26 82.37 0.00 0.00
April 281.06 99.60 164.22 62.88 101.33 0.00 0.00
May 331.42 61.63 174.50 66.93 107.56 0.00 0.00
June 450.03 21.05 190.92 81.86 109.06 0.00 0.00
July 365.13 15.08 148.26 45.97 102.29 0.00 0.00
August 322.18 21.16 132.54 42.02 90.52 0.00 0.00
September 266.69 33.84 119.06 29.67 89.40 0.00 0.00
October 176.04 131.04 109.57 41.13 68.43 0.00 0.00
November 117.69 195.08 97.37 39.78 57.60 0.00 0.00
December 85.94 250.63 81.25 30.39 50.86 0.00 0.00
               
Annual Sum or Average 228.72 118.67 126.67 45.26 81.41 0.00 0.00
Minimum of Months 80.23 15.08 81.25 25.86 50.86 0.00 0.00
Maximum of Months 450.03 250.63 190.92 81.86 109.06 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: T SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 445.74 214.50 307.64 234.61 73.04 0.00 0.00
February 279.28 204.98 219.81 142.52 77.29 0.00 0.00
March 273.48 183.94 201.63 101.05 100.59 0.00 0.00
April 387.31 94.45 225.90 115.34 110.57 0.00 0.00
May 347.59 60.50 189.49 80.92 108.57 0.00 0.00
June 419.91 20.05 183.96 80.12 103.83 0.00 0.00
July 385.38 14.48 166.35 64.18 102.17 0.00 0.00
August 394.16 20.81 175.55 77.35 98.20 0.00 0.00
September 391.72 32.32 192.40 86.59 105.81 0.00 0.00
October 419.88 128.05 259.49 172.94 86.55 0.00 0.00
November 388.17 195.86 273.34 199.76 73.58 0.00 0.00
December 390.54 251.37 283.64 213.99 69.64 0.00 0.00
               
Annual Sum or Average 377.52 118.09 223.34 130.80 92.54 0.00 0.00
Minimum of Months 273.48 14.48 166.35 64.18 69.64 0.00 0.00
Maximum of Months 445.74 251.37 307.64 234.61 110.57 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: T NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 98.77 196.64 93.45 40.03 53.42 0.00 0.00
February 81.80 191.28 96.49 35.77 60.72 0.00 0.00
March 138.09 175.50 123.12 40.01 83.12 0.00 0.00
April 274.00 91.84 166.83 67.34 99.49 0.00 0.00
May 336.38 59.29 180.68 74.25 106.43 0.00 0.00
June 455.15 20.34 195.09 88.28 106.81 0.00 0.00
July 393.88 14.37 165.57 64.04 101.53 0.00 0.00
August 347.58 20.27 148.32 56.56 91.76 0.00 0.00
September 278.39 31.44 127.86 38.22 89.64 0.00 0.00
October 177.11 122.66 117.11 48.36 68.75 0.00 0.00
November 95.16 180.90 92.56 36.75 55.81 0.00 0.00
December 70.50 232.62 83.61 33.67 49.95 0.00 0.00
               
Annual Sum or Average 229.60 111.10 132.71 52.01 80.70 0.00 0.00
Minimum of Months 70.50 14.37 83.61 33.67 49.95 0.00 0.00
Maximum of Months 455.15 232.62 195.09 88.28 106.81 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: T N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 24.00 132.87 29.81 0.00 29.81 0.00 0.00
February 17.22 128.75 33.96 0.00 33.96 0.00 0.00
March 42.56 116.81 45.15 0.01 45.14 0.00 0.00
April 93.27 59.83 55.17 0.73 54.44 0.00 0.00
May 130.92 36.35 64.98 5.63 59.35 0.00 0.00
June 205.64 12.42 74.53 13.34 61.19 0.00 0.00
July 178.54 8.86 63.60 6.45 57.15 0.00 0.00
August 146.45 12.56 51.66 1.38 50.27 0.00 0.00
September 121.16 20.32 48.61 0.03 48.58 0.00 0.00
October 56.87 81.65 37.59 0.00 37.59 0.00 0.00
November 24.01 121.90 31.32 0.00 31.32 0.00 0.00
December 15.42 156.26 27.84 0.00 27.84 0.00 0.00
               
Annual Sum or Average 88.33 73.82 47.07 2.30 44.76 0.00 0.00
Minimum of Months 15.42 8.86 27.84 0.00 27.84 0.00 0.00
Maximum of Months 205.64 156.26 74.53 13.34 61.19 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: T N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 23.85 132.70 29.81 0.00 29.81 0.00 0.00
February 17.03 128.82 33.96 0.00 33.96 0.00 0.00
March 42.33 116.78 45.15 0.01 45.14 0.00 0.00
April 93.10 59.79 55.17 0.73 54.44 0.00 0.00
May 130.81 36.33 64.98 5.63 59.35 0.00 0.00
June 205.61 12.41 74.53 13.34 61.19 0.00 0.00
July 178.50 8.86 63.60 6.45 57.15 0.00 0.00
August 146.41 12.55 51.66 1.38 50.27 0.00 0.00
September 121.12 20.32 48.61 0.03 48.58 0.00 0.00
October 56.69 81.80 37.59 0.00 37.59 0.00 0.00
November 23.90 121.63 31.32 0.00 31.32 0.00 0.00
December 15.31 156.17 27.84 0.00 27.84 0.00 0.00
               
Annual Sum or Average 88.22 73.79 47.07 2.30 44.76 0.00 0.00
Minimum of Months 15.31 8.86 27.84 0.00 27.84 0.00 0.00
Maximum of Months 205.61 156.17 74.53 13.34 61.19 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: T S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 371.65 134.84 244.00 194.57 49.43 0.00 0.00
February 213.93 130.12 157.28 106.75 50.53 0.00 0.00
March 179.82 119.52 123.66 61.05 62.61 0.00 0.00
April 213.38 63.03 114.25 48.73 65.51 0.00 0.00
May 151.81 40.78 73.79 12.30 61.49 0.00 0.00
June 178.58 13.58 63.39 5.18 58.21 0.00 0.00
July 176.58 9.43 64.37 6.59 57.78 0.00 0.00
August 200.75 13.23 78.89 22.17 56.71 0.00 0.00
September 241.00 20.52 113.16 48.41 64.75 0.00 0.00
October 301.91 80.29 179.97 124.58 55.39 0.00 0.00
November 317.54 122.77 212.09 163.00 49.09 0.00 0.00
December 333.60 157.46 227.87 180.33 47.54 0.00 0.00
               
Annual Sum or Average 240.29 75.24 137.70 81.09 56.61 0.00 0.00
Minimum of Months 151.81 9.43 63.39 5.18 47.54 0.00 0.00
Maximum of Months 371.65 157.46 244.00 194.57 65.51 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: T S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 371.51 134.79 244.00 194.57 49.43 0.00 0.00
February 213.68 130.19 157.28 106.75 50.53 0.00 0.00
March 179.58 119.53 123.66 61.05 62.61 0.00 0.00
April 213.19 63.02 114.25 48.73 65.51 0.00 0.00
May 151.65 40.77 73.79 12.30 61.49 0.00 0.00
June 178.49 13.58 63.39 5.18 58.21 0.00 0.00
July 176.50 9.43 64.37 6.59 57.78 0.00 0.00
August 200.67 13.23 78.89 22.17 56.71 0.00 0.00
September 240.93 20.52 113.16 48.41 64.75 0.00 0.00
October 301.75 80.29 179.97 124.58 55.39 0.00 0.00
November 317.42 122.70 212.09 163.00 49.09 0.00 0.00
December 333.43 157.46 227.87 180.33 47.54 0.00 0.00
               
Annual Sum or Average 240.14 75.23 137.70 81.09 56.61 0.00 0.00
Minimum of Months 151.65 9.43 63.39 5.18 47.54 0.00 0.00
Maximum of Months 371.51 157.46 244.00 194.57 65.51 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: T CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 19.34 21.98 15.27 9.61 5.67 0.00 0.00
February 16.98 21.50 15.00 8.58 6.42 0.00 0.00
March 24.08 19.08 18.71 9.60 9.11 0.00 0.00
April 43.74 10.39 26.79 15.98 10.81 0.00 0.00
May 48.44 6.95 27.76 16.47 11.30 0.00 0.00
June 57.99 2.69 28.93 17.98 10.95 0.00 0.00
July 49.54 2.11 24.47 13.82 10.65 0.00 0.00
August 46.31 2.95 23.19 13.24 9.95 0.00 0.00
September 36.15 4.22 19.02 9.16 9.85 0.00 0.00
October 29.39 13.70 19.08 11.60 7.48 0.00 0.00
November 18.23 20.44 14.70 8.82 5.88 0.00 0.00
December 15.27 25.47 13.38 8.08 5.30 0.00 0.00
               
Annual Sum or Average 33.87 12.59 20.55 11.93 8.62 0.00 0.00
Minimum of Months 15.27 2.11 13.38 8.08 5.30 0.00 0.00
Maximum of Months 57.99 25.47 28.93 17.98 11.30 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: G CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 56.08 67.51 45.48 28.61 16.87 0.00 0.00
February 50.74 64.70 44.68 25.56 19.12 0.00 0.00
March 72.22 55.89 55.72 28.59 27.14 0.00 0.00
April 129.22 33.32 79.80 47.60 32.20 0.00 0.00
May 141.66 23.98 82.69 49.04 33.65 0.00 0.00
June 167.10 10.99 86.16 53.56 32.60 0.00 0.00
July 141.54 9.18 72.87 41.16 31.72 0.00 0.00
August 132.70 12.51 69.08 39.43 29.65 0.00 0.00
September 103.25 17.10 56.63 27.29 29.34 0.00 0.00
October 84.32 45.72 56.83 34.56 22.27 0.00 0.00
November 51.83 65.75 43.77 26.27 17.50 0.00 0.00
December 42.59 82.12 39.86 24.06 15.80 0.00 0.00
               
Annual Sum or Average 97.99 40.63 61.21 35.52 25.68 0.00 0.00
Minimum of Months 42.59 9.18 39.86 24.06 15.80 0.00 0.00
Maximum of Months 167.10 82.12 86.16 53.56 33.65 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: M CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 17.79 24.29 15.27 9.61 5.67 0.00 0.00
February 15.55 24.92 15.00 8.58 6.42 0.00 0.00
March 22.59 20.96 18.71 9.60 9.11 0.00 0.00
April 43.58 10.89 26.79 15.98 10.81 0.00 0.00
May 48.60 7.29 27.76 16.47 11.30 0.00 0.00
June 58.87 2.81 28.93 17.98 10.95 0.00 0.00
July 50.48 2.16 24.47 13.82 10.65 0.00 0.00
August 47.11 3.04 23.19 13.24 9.95 0.00 0.00
September 36.70 4.38 19.02 9.16 9.85 0.00 0.00
October 28.82 14.75 19.08 11.60 7.48 0.00 0.00
November 16.95 22.64 14.70 8.82 5.88 0.00 0.00
December 13.51 29.09 13.38 8.08 5.30 0.00 0.00
               
Annual Sum or Average 33.46 13.89 20.55 11.93 8.62 0.00 0.00
Minimum of Months 13.51 2.16 13.38 8.08 5.30 0.00 0.00
Maximum of Months 58.87 29.09 28.93 17.98 11.30 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: G SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.123269E+10 0.623637E+09 0.832099E+09 0.632484E+09 0.199615E+09 0.00 0.00
February 0.663152E+09 0.531587E+09 0.510127E+09 0.320822E+09 0.189306E+09 0.00 0.00
March 0.749756E+09 0.516634E+09 0.522649E+09 0.255246E+09 0.267403E+09 0.00 0.00
April 0.105418E+10 0.277621E+09 0.578763E+09 0.287416E+09 0.291347E+09 0.00 0.00
May 0.963324E+09 0.190866E+09 0.490971E+09 0.197147E+09 0.293824E+09 0.00 0.00
June 0.111204E+10 67020305.34 0.466013E+09 0.191043E+09 0.274970E+09 0.00 0.00
July 0.977407E+09 50780256.35 0.399165E+09 0.123506E+09 0.275660E+09 0.00 0.00
August 0.100732E+10 72369692.00 0.427931E+09 0.168237E+09 0.259694E+09 0.00 0.00
September 0.996274E+09 0.109043E+09 0.475913E+09 0.202288E+09 0.273625E+09 0.00 0.00
October 0.111143E+10 0.387711E+09 0.674814E+09 0.443837E+09 0.230976E+09 0.00 0.00
November 0.103641E+10 0.565897E+09 0.720953E+09 0.525605E+09 0.195348E+09 0.00 0.00
December 0.103377E+10 0.757130E+09 0.753374E+09 0.564395E+09 0.188980E+09 0.00 0.00
               
Annual Sum or Average 0.119378E+11 0.415030E+10 0.685277E+10 0.391203E+10 0.294075E+10 0.00 0.00
Minimum of Months 0.663152E+09 50780256.35 0.399165E+09 0.123506E+09 0.188980E+09 0.00 0.00
Maximum of Months 0.123269E+10 0.757130E+09 0.832099E+09 0.632484E+09 0.293824E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: G NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.319814E+09 0.615200E+09 0.258403E+09 0.111345E+09 0.147058E+09 0.00 0.00
February 0.197586E+09 0.511207E+09 0.211795E+09 62568269.37 0.149227E+09 0.00 0.00
March 0.390122E+09 0.489205E+09 0.312372E+09 91753945.33 0.220618E+09 0.00 0.00
April 0.748311E+09 0.261650E+09 0.425647E+09 0.162997E+09 0.262650E+09 0.00 0.00
May 0.908500E+09 0.169025E+09 0.467367E+09 0.179267E+09 0.288100E+09 0.00 0.00
June 0.118791E+10 57872412.23 0.494877E+09 0.212185E+09 0.282693E+09 0.00 0.00
July 0.990024E+09 44926263.97 0.397098E+09 0.123129E+09 0.273969E+09 0.00 0.00
August 0.870597E+09 64144606.56 0.354998E+09 0.112556E+09 0.242442E+09 0.00 0.00
September 0.692834E+09 0.101327E+09 0.308608E+09 76894046.92 0.231714E+09 0.00 0.00
October 0.460841E+09 0.395712E+09 0.293464E+09 0.110170E+09 0.183294E+09 0.00 0.00
November 0.284302E+09 0.583852E+09 0.252391E+09 0.103098E+09 0.149294E+09 0.00 0.00
December 0.206949E+09 0.768565E+09 0.217630E+09 81405036.02 0.136225E+09 0.00 0.00
               
Annual Sum or Average 0.725779E+10 0.406269E+10 0.399465E+10 0.142737E+10 0.256728E+10 0.00 0.00
Minimum of Months 0.197586E+09 44926263.97 0.211795E+09 62568269.37 0.136225E+09 0.00 0.00
Maximum of Months 0.118791E+10 0.768565E+09 0.494877E+09 0.212185E+09 0.288100E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: OFFICE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.121569E+10 0.627399E+09 0.823991E+09 0.628367E+09 0.195624E+09 0.00 0.00
February 0.699946E+09 0.523913E+09 0.531756E+09 0.344788E+09 0.186968E+09 0.00 0.00
March 0.762368E+09 0.509652E+09 0.540054E+09 0.270646E+09 0.269408E+09 0.00 0.00
April 0.101299E+10 0.309521E+09 0.585542E+09 0.298955E+09 0.286587E+09 0.00 0.00
May 0.927685E+09 0.236129E+09 0.507542E+09 0.216749E+09 0.290793E+09 0.00 0.00
June 0.104205E+10 0.113449E+09 0.476814E+09 0.207679E+09 0.269135E+09 0.00 0.00
July 0.954862E+09 0.107806E+09 0.445542E+09 0.171901E+09 0.273641E+09 0.00 0.00
August 0.101171E+10 0.140525E+09 0.470185E+09 0.207172E+09 0.263013E+09 0.00 0.00
September 0.975002E+09 0.187563E+09 0.498711E+09 0.224448E+09 0.274263E+09 0.00 0.00
October 0.111524E+10 0.450562E+09 0.695016E+09 0.463193E+09 0.231823E+09 0.00 0.00
November 0.101438E+10 0.589131E+09 0.708486E+09 0.517776E+09 0.190710E+09 0.00 0.00
December 0.104376E+10 0.754981E+09 0.759691E+09 0.573161E+09 0.186530E+09 0.00 0.00
               
Annual Sum or Average 0.117757E+11 0.455063E+10 0.704333E+10 0.412484E+10 0.291849E+10 0.00 0.00
Minimum of Months 0.699946E+09 0.107806E+09 0.445542E+09 0.171901E+09 0.186530E+09 0.00 0.00
Maximum of Months 0.121569E+10 0.754981E+09 0.823991E+09 0.628367E+09 0.290793E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: G NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.251556E+09 0.565562E+09 0.250295E+09 0.107228E+09 0.143067E+09 0.00 0.00
February 0.198570E+09 0.483725E+09 0.233423E+09 86534717.39 0.146889E+09 0.00 0.00
March 0.387648E+09 0.464564E+09 0.329776E+09 0.107154E+09 0.222622E+09 0.00 0.00
April 0.732165E+09 0.240466E+09 0.432427E+09 0.174537E+09 0.257890E+09 0.00 0.00
May 0.924444E+09 0.163030E+09 0.483939E+09 0.198869E+09 0.285070E+09 0.00 0.00
June 0.120242E+10 56284794.40 0.505679E+09 0.228821E+09 0.276858E+09 0.00 0.00
July 0.106834E+10 43347180.10 0.443474E+09 0.171524E+09 0.271951E+09 0.00 0.00
August 0.939992E+09 62015905.02 0.397251E+09 0.151491E+09 0.245760E+09 0.00 0.00
September 0.723128E+09 94120115.46 0.331406E+09 99054305.40 0.232352E+09 0.00 0.00
October 0.461782E+09 0.366494E+09 0.313667E+09 0.129526E+09 0.184141E+09 0.00 0.00
November 0.218188E+09 0.540975E+09 0.239924E+09 95268428.64 0.144656E+09 0.00 0.00
December 0.156305E+09 0.713941E+09 0.223946E+09 90171447.43 0.133775E+09 0.00 0.00
               
Annual Sum or Average 0.726453E+10 0.379453E+10 0.418521E+10 0.164018E+10 0.254503E+10 0.00 0.00
Minimum of Months 0.156305E+09 43347180.10 0.223946E+09 86534717.39 0.133775E+09 0.00 0.00
Maximum of Months 0.120242E+10 0.713941E+09 0.505679E+09 0.228821E+09 0.285070E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: G N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 56822338.90 0.385379E+09 79833222.32 0.00 79833222.32 0.00 0.00
February 39180643.53 0.335891E+09 82164655.87 0.00 82164655.87 0.00 0.00
March 0.117374E+09 0.316919E+09 0.120929E+09 13678.22 0.120915E+09 0.00 0.00
April 0.249191E+09 0.156702E+09 0.143009E+09 1893895.70 0.141116E+09 0.00 0.00
May 0.358329E+09 99548956.16 0.174031E+09 15072597.96 0.158958E+09 0.00 0.00
June 0.541420E+09 33788857.18 0.193172E+09 34569125.85 0.158603E+09 0.00 0.00
July 0.483185E+09 25783001.93 0.170349E+09 17270585.85 0.153079E+09 0.00 0.00
August 0.395123E+09 36858900.56 0.138358E+09 3709336.69 0.134649E+09 0.00 0.00
September 0.314117E+09 58840818.39 0.125999E+09 74957.01 0.125924E+09 0.00 0.00
October 0.146230E+09 0.240876E+09 0.100680E+09 0.00 0.100680E+09 0.00 0.00
November 51088447.48 0.360320E+09 81179262.24 0.00 81179262.24 0.00 0.00
December 28136267.75 0.487079E+09 74571601.52 0.00 74571601.52 0.00 0.00
               
Annual Sum or Average 0.278020E+10 0.253799E+10 0.148428E+10 72604177.28 0.141167E+10 0.00 0.00
Minimum of Months 28136267.75 25783001.93 74571601.52 0.00 74571601.52 0.00 0.00
Maximum of Months 0.541420E+09 0.487079E+09 0.193172E+09 34569125.85 0.158958E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: G N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 56774749.16 0.385216E+09 79833222.32 0.00 79833222.32 0.00 0.00
February 38974620.37 0.336368E+09 82164655.87 0.00 82164655.87 0.00 0.00
March 0.117103E+09 0.317249E+09 0.120929E+09 13678.22 0.120915E+09 0.00 0.00
April 0.249026E+09 0.156744E+09 0.143009E+09 1893895.70 0.141116E+09 0.00 0.00
May 0.358201E+09 99558753.94 0.174031E+09 15072597.96 0.158958E+09 0.00 0.00
June 0.541364E+09 33783098.66 0.193172E+09 34569125.85 0.158603E+09 0.00 0.00
July 0.483107E+09 25786585.14 0.170349E+09 17270585.85 0.153079E+09 0.00 0.00
August 0.395046E+09 36872270.74 0.138358E+09 3709336.69 0.134649E+09 0.00 0.00
September 0.314061E+09 58850379.60 0.125999E+09 74957.01 0.125924E+09 0.00 0.00
October 0.146087E+09 0.240961E+09 0.100680E+09 0.00 0.100680E+09 0.00 0.00
November 51054732.68 0.360170E+09 81179262.24 0.00 81179262.24 0.00 0.00
December 28049539.07 0.487241E+09 74571601.52 0.00 74571601.52 0.00 0.00
               
Annual Sum or Average 0.277885E+10 0.253880E+10 0.148428E+10 72604177.28 0.141167E+10 0.00 0.00
Minimum of Months 28049539.07 25786585.14 74571601.52 0.00 74571601.52 0.00 0.00
Maximum of Months 0.541364E+09 0.487241E+09 0.193172E+09 34569125.85 0.158958E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: G S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.100101E+10 0.378981E+09 0.653529E+09 0.521139E+09 0.132390E+09 0.00 0.00
February 0.521957E+09 0.333675E+09 0.380497E+09 0.258253E+09 0.122244E+09 0.00 0.00
March 0.490611E+09 0.327638E+09 0.331207E+09 0.163506E+09 0.167701E+09 0.00 0.00
April 0.566738E+09 0.169144E+09 0.296125E+09 0.126312E+09 0.169812E+09 0.00 0.00
May 0.419750E+09 0.114988E+09 0.197635E+09 32952456.36 0.164682E+09 0.00 0.00
June 0.474579E+09 38926514.58 0.164307E+09 13427492.44 0.150879E+09 0.00 0.00
July 0.480965E+09 29080074.03 0.172417E+09 17647504.23 0.154769E+09 0.00 0.00
August 0.545470E+09 41601894.93 0.211292E+09 59390576.21 0.151901E+09 0.00 0.00
September 0.630973E+09 63030357.54 0.293304E+09 0.125469E+09 0.167835E+09 0.00 0.00
October 0.813322E+09 0.231973E+09 0.482030E+09 0.333667E+09 0.148363E+09 0.00 0.00
November 0.823927E+09 0.341102E+09 0.549741E+09 0.422508E+09 0.127233E+09 0.00 0.00
December 0.884935E+09 0.460126E+09 0.610316E+09 0.482989E+09 0.127327E+09 0.00 0.00
               
Annual Sum or Average 0.765424E+10 0.253027E+10 0.434240E+10 0.255726E+10 0.178514E+10 0.00 0.00
Minimum of Months 0.419750E+09 29080074.03 0.164307E+09 13427492.44 0.122244E+09 0.00 0.00
Maximum of Months 0.100101E+10 0.460126E+09 0.653529E+09 0.521139E+09 0.169812E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: G S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.100112E+10 0.378752E+09 0.653529E+09 0.521139E+09 0.132390E+09 0.00 0.00
February 0.522072E+09 0.333268E+09 0.380497E+09 0.258253E+09 0.122244E+09 0.00 0.00
March 0.490358E+09 0.327657E+09 0.331207E+09 0.163506E+09 0.167701E+09 0.00 0.00
April 0.565525E+09 0.170447E+09 0.296125E+09 0.126312E+09 0.169812E+09 0.00 0.00
May 0.417821E+09 0.116603E+09 0.197635E+09 32952456.36 0.164682E+09 0.00 0.00
June 0.471907E+09 40101677.05 0.164307E+09 13427492.44 0.150879E+09 0.00 0.00
July 0.477900E+09 30226313.95 0.172417E+09 17647504.23 0.154769E+09 0.00 0.00
August 0.543092E+09 43062235.74 0.211292E+09 59390576.21 0.151901E+09 0.00 0.00
September 0.628961E+09 64890904.53 0.293304E+09 0.125469E+09 0.167835E+09 0.00 0.00
October 0.812058E+09 0.233534E+09 0.482030E+09 0.333667E+09 0.148363E+09 0.00 0.00
November 0.823700E+09 0.341493E+09 0.549741E+09 0.422508E+09 0.127233E+09 0.00 0.00
December 0.885070E+09 0.459838E+09 0.610316E+09 0.482989E+09 0.127327E+09 0.00 0.00
               
Annual Sum or Average 0.763958E+10 0.253987E+10 0.434240E+10 0.255726E+10 0.178514E+10 0.00 0.00
Minimum of Months 0.417821E+09 30226313.95 0.164307E+09 13427492.44 0.122244E+09 0.00 0.00
Maximum of Months 0.100112E+10 0.459838E+09 0.653529E+09 0.521139E+09 0.169812E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: M SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.121737E+10 0.635322E+09 0.832099E+09 0.632484E+09 0.199615E+09 0.00 0.00
February 0.637458E+09 0.570349E+09 0.510127E+09 0.320822E+09 0.189306E+09 0.00 0.00
March 0.713840E+09 0.558268E+09 0.522649E+09 0.255246E+09 0.267403E+09 0.00 0.00
April 0.104087E+10 0.283549E+09 0.578763E+09 0.287416E+09 0.291347E+09 0.00 0.00
May 0.952079E+09 0.193836E+09 0.490971E+09 0.197147E+09 0.293824E+09 0.00 0.00
June 0.111032E+10 65591670.19 0.466013E+09 0.191043E+09 0.274970E+09 0.00 0.00
July 0.985348E+09 46630913.66 0.399165E+09 0.123506E+09 0.275660E+09 0.00 0.00
August 0.101613E+10 64990898.75 0.427931E+09 0.168237E+09 0.259694E+09 0.00 0.00
September 0.100615E+10 96708779.44 0.475913E+09 0.202288E+09 0.273625E+09 0.00 0.00
October 0.111330E+10 0.377291E+09 0.674814E+09 0.443837E+09 0.230976E+09 0.00 0.00
November 0.103333E+10 0.560421E+09 0.720953E+09 0.525605E+09 0.195348E+09 0.00 0.00
December 0.102768E+10 0.757294E+09 0.753374E+09 0.564395E+09 0.188980E+09 0.00 0.00
               
Annual Sum or Average 0.118539E+11 0.421025E+10 0.685277E+10 0.391203E+10 0.294075E+10 0.00 0.00
Minimum of Months 0.637458E+09 46630913.66 0.399165E+09 0.123506E+09 0.188980E+09 0.00 0.00
Maximum of Months 0.121737E+10 0.757294E+09 0.832099E+09 0.632484E+09 0.293824E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: M NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.306444E+09 0.646993E+09 0.258403E+09 0.111345E+09 0.147058E+09 0.00 0.00
February 0.173819E+09 0.581837E+09 0.211795E+09 62568269.37 0.149227E+09 0.00 0.00
March 0.352460E+09 0.552473E+09 0.312372E+09 91753945.33 0.220618E+09 0.00 0.00
April 0.737740E+09 0.271033E+09 0.425647E+09 0.162997E+09 0.262650E+09 0.00 0.00
May 0.900818E+09 0.172084E+09 0.467367E+09 0.179267E+09 0.288100E+09 0.00 0.00
June 0.118947E+10 56872363.86 0.494877E+09 0.212185E+09 0.282693E+09 0.00 0.00
July 0.100029E+10 41687549.29 0.397098E+09 0.123129E+09 0.273969E+09 0.00 0.00
August 0.882622E+09 58497837.63 0.354998E+09 0.112556E+09 0.242442E+09 0.00 0.00
September 0.706167E+09 91251932.10 0.308608E+09 76894046.92 0.231714E+09 0.00 0.00
October 0.468391E+09 0.384782E+09 0.293464E+09 0.110170E+09 0.183294E+09 0.00 0.00
November 0.288072E+09 0.573316E+09 0.252391E+09 0.103098E+09 0.149294E+09 0.00 0.00
December 0.208371E+09 0.762581E+09 0.217630E+09 81405036.02 0.136225E+09 0.00 0.00
               
Annual Sum or Average 0.721466E+10 0.419341E+10 0.399465E+10 0.142737E+10 0.256728E+10 0.00 0.00
Minimum of Months 0.173819E+09 41687549.29 0.211795E+09 62568269.37 0.136225E+09 0.00 0.00
Maximum of Months 0.118947E+10 0.762581E+09 0.494877E+09 0.212185E+09 0.288100E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: M SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.118570E+10 0.625795E+09 0.823991E+09 0.628367E+09 0.195624E+09 0.00 0.00
February 0.661707E+09 0.564695E+09 0.531756E+09 0.344788E+09 0.186968E+09 0.00 0.00
March 0.719487E+09 0.540914E+09 0.540054E+09 0.270646E+09 0.269408E+09 0.00 0.00
April 0.101836E+10 0.258094E+09 0.585542E+09 0.298955E+09 0.286587E+09 0.00 0.00
May 0.948804E+09 0.171834E+09 0.507542E+09 0.216749E+09 0.290793E+09 0.00 0.00
June 0.111403E+10 56089868.00 0.476814E+09 0.207679E+09 0.269135E+09 0.00 0.00
July 0.105804E+10 41730940.40 0.445542E+09 0.171901E+09 0.273641E+09 0.00 0.00
August 0.108048E+10 60223819.85 0.470185E+09 0.207172E+09 0.263013E+09 0.00 0.00
September 0.103575E+10 90176738.51 0.498711E+09 0.224448E+09 0.274263E+09 0.00 0.00
October 0.113214E+10 0.367787E+09 0.695016E+09 0.463193E+09 0.231823E+09 0.00 0.00
November 0.999937E+09 0.552432E+09 0.708486E+09 0.517776E+09 0.190710E+09 0.00 0.00
December 0.102323E+10 0.750465E+09 0.759691E+09 0.573161E+09 0.186530E+09 0.00 0.00
               
Annual Sum or Average 0.119777E+11 0.408024E+10 0.704333E+10 0.412484E+10 0.291849E+10 0.00 0.00
Minimum of Months 0.661707E+09 41730940.40 0.445542E+09 0.171901E+09 0.186530E+09 0.00 0.00
Maximum of Months 0.118570E+10 0.750465E+09 0.823991E+09 0.628367E+09 0.290793E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: M NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.235349E+09 0.594279E+09 0.250295E+09 0.107228E+09 0.143067E+09 0.00 0.00
February 0.171166E+09 0.548279E+09 0.233423E+09 86534717.39 0.146889E+09 0.00 0.00
March 0.347752E+09 0.523508E+09 0.329776E+09 0.107154E+09 0.222622E+09 0.00 0.00
April 0.719425E+09 0.248163E+09 0.432427E+09 0.174537E+09 0.257890E+09 0.00 0.00
May 0.915704E+09 0.165605E+09 0.483939E+09 0.198869E+09 0.285070E+09 0.00 0.00
June 0.120358E+10 55136430.04 0.505679E+09 0.228821E+09 0.276858E+09 0.00 0.00
July 0.107836E+10 39953238.95 0.443474E+09 0.171524E+09 0.271951E+09 0.00 0.00
August 0.951721E+09 56251288.22 0.397251E+09 0.151491E+09 0.245760E+09 0.00 0.00
September 0.736903E+09 84627146.58 0.331406E+09 99054305.40 0.232352E+09 0.00 0.00
October 0.469129E+09 0.356182E+09 0.313667E+09 0.129526E+09 0.184141E+09 0.00 0.00
November 0.221965E+09 0.530892E+09 0.239924E+09 95268428.64 0.144656E+09 0.00 0.00
December 0.157509E+09 0.709109E+09 0.223946E+09 90171447.43 0.133775E+09 0.00 0.00
               
Annual Sum or Average 0.720856E+10 0.391198E+10 0.418521E+10 0.164018E+10 0.254503E+10 0.00 0.00
Minimum of Months 0.157509E+09 39953238.95 0.223946E+09 86534717.39 0.133775E+09 0.00 0.00
Maximum of Months 0.120358E+10 0.709109E+09 0.505679E+09 0.228821E+09 0.285070E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: M N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 51446019.86 0.402490E+09 79833222.32 0.00 79833222.32 0.00 0.00
February 30407842.08 0.369680E+09 82164655.87 0.00 82164655.87 0.00 0.00
March 0.102924E+09 0.347100E+09 0.120929E+09 13678.22 0.120915E+09 0.00 0.00
April 0.245664E+09 0.160638E+09 0.143009E+09 1893895.70 0.141116E+09 0.00 0.00
May 0.356548E+09 0.100207E+09 0.174031E+09 15072597.96 0.158958E+09 0.00 0.00
June 0.544392E+09 32948799.33 0.193172E+09 34569125.85 0.158603E+09 0.00 0.00
July 0.489731E+09 24036000.56 0.170349E+09 17270585.85 0.153079E+09 0.00 0.00
August 0.402266E+09 34016221.65 0.138358E+09 3709336.69 0.134649E+09 0.00 0.00
September 0.321466E+09 53953382.91 0.125999E+09 74957.01 0.125924E+09 0.00 0.00
October 0.150275E+09 0.235311E+09 0.100680E+09 0.00 0.100680E+09 0.00 0.00
November 52431231.86 0.357255E+09 81179262.24 0.00 81179262.24 0.00 0.00
December 27918443.11 0.488964E+09 74571601.52 0.00 74571601.52 0.00 0.00
               
Annual Sum or Average 0.277547E+10 0.260660E+10 0.148428E+10 72604177.28 0.141167E+10 0.00 0.00
Minimum of Months 27918443.11 24036000.56 74571601.52 0.00 74571601.52 0.00 0.00
Maximum of Months 0.544392E+09 0.488964E+09 0.193172E+09 34569125.85 0.158958E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: M N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 51371839.38 0.402335E+09 79833222.32 0.00 79833222.32 0.00 0.00
February 30302313.68 0.369819E+09 82164655.87 0.00 82164655.87 0.00 0.00
March 0.102748E+09 0.347187E+09 0.120929E+09 13678.22 0.120915E+09 0.00 0.00
April 0.245495E+09 0.160649E+09 0.143009E+09 1893895.70 0.141116E+09 0.00 0.00
May 0.356417E+09 0.100207E+09 0.174031E+09 15072597.96 0.158958E+09 0.00 0.00
June 0.544338E+09 32938812.50 0.193172E+09 34569125.85 0.158603E+09 0.00 0.00
July 0.489664E+09 24035312.94 0.170349E+09 17270585.85 0.153079E+09 0.00 0.00
August 0.402196E+09 34022440.39 0.138358E+09 3709336.69 0.134649E+09 0.00 0.00
September 0.321406E+09 53957753.56 0.125999E+09 74957.01 0.125924E+09 0.00 0.00
October 0.150133E+09 0.235364E+09 0.100680E+09 0.00 0.100680E+09 0.00 0.00
November 52367553.90 0.357148E+09 81179262.24 0.00 81179262.24 0.00 0.00
December 27802731.29 0.489185E+09 74571601.52 0.00 74571601.52 0.00 0.00
               
Annual Sum or Average 0.277424E+10 0.260685E+10 0.148428E+10 72604177.28 0.141167E+10 0.00 0.00
Minimum of Months 27802731.29 24035312.94 74571601.52 0.00 74571601.52 0.00 0.00
Maximum of Months 0.544338E+09 0.489185E+09 0.193172E+09 34569125.85 0.158958E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: M S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.992043E+09 0.384271E+09 0.653529E+09 0.521139E+09 0.132390E+09 0.00 0.00
February 0.509975E+09 0.347924E+09 0.380497E+09 0.258253E+09 0.122244E+09 0.00 0.00
March 0.475103E+09 0.345036E+09 0.331207E+09 0.163506E+09 0.167701E+09 0.00 0.00
April 0.561093E+09 0.170979E+09 0.296125E+09 0.126312E+09 0.169812E+09 0.00 0.00
May 0.416245E+09 0.115191E+09 0.197635E+09 32952456.36 0.164682E+09 0.00 0.00
June 0.476458E+09 37546149.94 0.164307E+09 13427492.44 0.150879E+09 0.00 0.00
July 0.486815E+09 26653957.67 0.172417E+09 17647504.23 0.154769E+09 0.00 0.00
August 0.550905E+09 37577549.31 0.211292E+09 59390576.21 0.151901E+09 0.00 0.00
September 0.635812E+09 56568053.11 0.293304E+09 0.125469E+09 0.167835E+09 0.00 0.00
October 0.812955E+09 0.226759E+09 0.482030E+09 0.333667E+09 0.148363E+09 0.00 0.00
November 0.820658E+09 0.338775E+09 0.549741E+09 0.422508E+09 0.127233E+09 0.00 0.00
December 0.879518E+09 0.461613E+09 0.610316E+09 0.482989E+09 0.127327E+09 0.00 0.00
               
Annual Sum or Average 0.761758E+10 0.254889E+10 0.434240E+10 0.255726E+10 0.178514E+10 0.00 0.00
Minimum of Months 0.416245E+09 26653957.67 0.164307E+09 13427492.44 0.122244E+09 0.00 0.00
Maximum of Months 0.992043E+09 0.461613E+09 0.653529E+09 0.521139E+09 0.169812E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: M S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.991944E+09 0.384249E+09 0.653529E+09 0.521139E+09 0.132390E+09 0.00 0.00
February 0.509817E+09 0.348015E+09 0.380497E+09 0.258253E+09 0.122244E+09 0.00 0.00
March 0.474858E+09 0.345144E+09 0.331207E+09 0.163506E+09 0.167701E+09 0.00 0.00
April 0.560860E+09 0.171022E+09 0.296125E+09 0.126312E+09 0.169812E+09 0.00 0.00
May 0.415989E+09 0.115233E+09 0.197635E+09 32952456.36 0.164682E+09 0.00 0.00
June 0.476278E+09 37554260.98 0.164307E+09 13427492.44 0.150879E+09 0.00 0.00
July 0.486648E+09 26665924.81 0.172417E+09 17647504.23 0.154769E+09 0.00 0.00
August 0.550744E+09 37602905.78 0.211292E+09 59390576.21 0.151901E+09 0.00 0.00
September 0.635707E+09 56584336.53 0.293304E+09 0.125469E+09 0.167835E+09 0.00 0.00
October 0.812791E+09 0.226800E+09 0.482030E+09 0.333667E+09 0.148363E+09 0.00 0.00
November 0.820584E+09 0.338733E+09 0.549741E+09 0.422508E+09 0.127233E+09 0.00 0.00
December 0.879391E+09 0.461650E+09 0.610316E+09 0.482989E+09 0.127327E+09 0.00 0.00
               
Annual Sum or Average 0.761561E+10 0.254925E+10 0.434240E+10 0.255726E+10 0.178514E+10 0.00 0.00
Minimum of Months 0.415989E+09 26665924.81 0.164307E+09 13427492.44 0.122244E+09 0.00 0.00
Maximum of Months 0.991944E+09 0.461650E+09 0.653529E+09 0.521139E+09 0.169812E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: T SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.122784E+10 0.583681E+09 0.832099E+09 0.632484E+09 0.199615E+09 0.00 0.00
February 0.653470E+09 0.499235E+09 0.510127E+09 0.320822E+09 0.189306E+09 0.00 0.00
March 0.726108E+09 0.506391E+09 0.522649E+09 0.255246E+09 0.267403E+09 0.00 0.00
April 0.102578E+10 0.267415E+09 0.578763E+09 0.287416E+09 0.291347E+09 0.00 0.00
May 0.933657E+09 0.181726E+09 0.490971E+09 0.197147E+09 0.293824E+09 0.00 0.00
June 0.108435E+10 60531303.63 0.466013E+09 0.191043E+09 0.274970E+09 0.00 0.00
July 0.959846E+09 43413164.12 0.399165E+09 0.123506E+09 0.275660E+09 0.00 0.00
August 0.991779E+09 60259488.59 0.427931E+09 0.168237E+09 0.259694E+09 0.00 0.00
September 0.985862E+09 89765364.74 0.475913E+09 0.202288E+09 0.273625E+09 0.00 0.00
October 0.110727E+10 0.351447E+09 0.674814E+09 0.443837E+09 0.230976E+09 0.00 0.00
November 0.104062E+10 0.515203E+09 0.720953E+09 0.525605E+09 0.195348E+09 0.00 0.00
December 0.105194E+10 0.678960E+09 0.753374E+09 0.564395E+09 0.188980E+09 0.00 0.00
               
Annual Sum or Average 0.117885E+11 0.383803E+10 0.685277E+10 0.391203E+10 0.294075E+10 0.00 0.00
Minimum of Months 0.653470E+09 43413164.12 0.399165E+09 0.123506E+09 0.188980E+09 0.00 0.00
Maximum of Months 0.122784E+10 0.678960E+09 0.832099E+09 0.632484E+09 0.293824E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: T NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.326594E+09 0.570399E+09 0.258403E+09 0.111345E+09 0.147058E+09 0.00 0.00
February 0.194096E+09 0.488359E+09 0.211795E+09 62568269.37 0.149227E+09 0.00 0.00
March 0.370659E+09 0.493193E+09 0.312372E+09 91753945.33 0.220618E+09 0.00 0.00
April 0.728513E+09 0.258154E+09 0.425647E+09 0.162997E+09 0.262650E+09 0.00 0.00
May 0.887681E+09 0.165064E+09 0.467367E+09 0.179267E+09 0.288100E+09 0.00 0.00
June 0.116649E+10 54565510.80 0.494877E+09 0.212185E+09 0.282693E+09 0.00 0.00
July 0.977969E+09 40395120.41 0.397098E+09 0.123129E+09 0.273969E+09 0.00 0.00
August 0.862940E+09 56680516.48 0.354998E+09 0.112556E+09 0.242442E+09 0.00 0.00
September 0.691254E+09 87721746.56 0.308608E+09 76894046.92 0.231714E+09 0.00 0.00
October 0.471518E+09 0.350972E+09 0.293464E+09 0.110170E+09 0.183294E+09 0.00 0.00
November 0.305049E+09 0.505647E+09 0.252391E+09 0.103098E+09 0.149294E+09 0.00 0.00
December 0.230186E+09 0.671281E+09 0.217630E+09 81405036.02 0.136225E+09 0.00 0.00
               
Annual Sum or Average 0.721295E+10 0.374243E+10 0.399465E+10 0.142737E+10 0.256728E+10 0.00 0.00
Minimum of Months 0.194096E+09 40395120.41 0.211795E+09 62568269.37 0.136225E+09 0.00 0.00
Maximum of Months 0.116649E+10 0.671281E+09 0.494877E+09 0.212185E+09 0.288100E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: T SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.119386E+10 0.574524E+09 0.823991E+09 0.628367E+09 0.195624E+09 0.00 0.00
February 0.675645E+09 0.495895E+09 0.531756E+09 0.344788E+09 0.186968E+09 0.00 0.00
March 0.732499E+09 0.492674E+09 0.540054E+09 0.270646E+09 0.269408E+09 0.00 0.00
April 0.100392E+10 0.244815E+09 0.585542E+09 0.298955E+09 0.286587E+09 0.00 0.00
May 0.930981E+09 0.162035E+09 0.507542E+09 0.216749E+09 0.290793E+09 0.00 0.00
June 0.108839E+10 51978365.26 0.476814E+09 0.207679E+09 0.269135E+09 0.00 0.00
July 0.103221E+10 38771756.01 0.445542E+09 0.171901E+09 0.273641E+09 0.00 0.00
August 0.105572E+10 55732385.00 0.470185E+09 0.207172E+09 0.263013E+09 0.00 0.00
September 0.101535E+10 83762710.14 0.498711E+09 0.224448E+09 0.274263E+09 0.00 0.00
October 0.112461E+10 0.342958E+09 0.695016E+09 0.463193E+09 0.231823E+09 0.00 0.00
November 0.100613E+10 0.507661E+09 0.708486E+09 0.517776E+09 0.190710E+09 0.00 0.00
December 0.104602E+10 0.673263E+09 0.759691E+09 0.573161E+09 0.186530E+09 0.00 0.00
               
Annual Sum or Average 0.119053E+11 0.372407E+10 0.704333E+10 0.412484E+10 0.291849E+10 0.00 0.00
Minimum of Months 0.675645E+09 38771756.01 0.445542E+09 0.171901E+09 0.186530E+09 0.00 0.00
Maximum of Months 0.119386E+10 0.673263E+09 0.823991E+09 0.628367E+09 0.290793E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: T NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.264546E+09 0.526682E+09 0.250295E+09 0.107228E+09 0.143067E+09 0.00 0.00
February 0.197881E+09 0.462740E+09 0.233423E+09 86534717.39 0.146889E+09 0.00 0.00
March 0.369870E+09 0.470052E+09 0.329776E+09 0.107154E+09 0.222622E+09 0.00 0.00
April 0.710217E+09 0.238048E+09 0.432427E+09 0.174537E+09 0.257890E+09 0.00 0.00
May 0.900948E+09 0.158800E+09 0.483939E+09 0.198869E+09 0.285070E+09 0.00 0.00
June 0.117974E+10 52733245.29 0.505679E+09 0.228821E+09 0.276858E+09 0.00 0.00
July 0.105497E+10 38488166.69 0.443474E+09 0.171524E+09 0.271951E+09 0.00 0.00
August 0.930970E+09 54286920.82 0.397251E+09 0.151491E+09 0.245760E+09 0.00 0.00
September 0.721585E+09 81487728.57 0.331406E+09 99054305.40 0.232352E+09 0.00 0.00
October 0.474368E+09 0.328527E+09 0.313667E+09 0.129526E+09 0.184141E+09 0.00 0.00
November 0.246667E+09 0.468889E+09 0.239924E+09 95268428.64 0.144656E+09 0.00 0.00
December 0.188824E+09 0.623053E+09 0.223946E+09 90171447.43 0.133775E+09 0.00 0.00
               
Annual Sum or Average 0.724059E+10 0.350379E+10 0.418521E+10 0.164018E+10 0.254503E+10 0.00 0.00
Minimum of Months 0.188824E+09 38488166.69 0.223946E+09 86534717.39 0.133775E+09 0.00 0.00
Maximum of Months 0.117974E+10 0.623053E+09 0.505679E+09 0.228821E+09 0.285070E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: T N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 64283482.03 0.355873E+09 79833222.32 0.00 79833222.32 0.00 0.00
February 41656278.67 0.311466E+09 82164655.87 0.00 82164655.87 0.00 0.00
March 0.113980E+09 0.312857E+09 0.120929E+09 13678.22 0.120915E+09 0.00 0.00
April 0.241765E+09 0.155070E+09 0.143009E+09 1893895.70 0.141116E+09 0.00 0.00
May 0.350647E+09 97361774.80 0.174031E+09 15072597.96 0.158958E+09 0.00 0.00
June 0.533029E+09 32187185.14 0.193172E+09 34569125.85 0.158603E+09 0.00 0.00
July 0.478192E+09 23738104.98 0.170349E+09 17270585.85 0.153079E+09 0.00 0.00
August 0.392257E+09 33628598.85 0.138358E+09 3709336.69 0.134649E+09 0.00 0.00
September 0.314051E+09 52679703.37 0.125999E+09 74957.01 0.125924E+09 0.00 0.00
October 0.152331E+09 0.218696E+09 0.100680E+09 0.00 0.100680E+09 0.00 0.00
November 62239628.07 0.315962E+09 81179262.24 0.00 81179262.24 0.00 0.00
December 41295912.55 0.418531E+09 74571601.52 0.00 74571601.52 0.00 0.00
               
Annual Sum or Average 0.278572E+10 0.232805E+10 0.148428E+10 72604177.28 0.141167E+10 0.00 0.00
Minimum of Months 41295912.55 23738104.98 74571601.52 0.00 74571601.52 0.00 0.00
Maximum of Months 0.533029E+09 0.418531E+09 0.193172E+09 34569125.85 0.158958E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: T N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 63871735.73 0.355418E+09 79833222.32 0.00 79833222.32 0.00 0.00
February 41191216.68 0.311639E+09 82164655.87 0.00 82164655.87 0.00 0.00
March 0.113386E+09 0.312792E+09 0.120929E+09 13678.22 0.120915E+09 0.00 0.00
April 0.241308E+09 0.154983E+09 0.143009E+09 1893895.70 0.141116E+09 0.00 0.00
May 0.350361E+09 97310769.74 0.174031E+09 15072597.96 0.158958E+09 0.00 0.00
June 0.532932E+09 32158378.26 0.193172E+09 34569125.85 0.158603E+09 0.00 0.00
July 0.478084E+09 23724270.76 0.170349E+09 17270585.85 0.153079E+09 0.00 0.00
August 0.392139E+09 33617658.71 0.138358E+09 3709336.69 0.134649E+09 0.00 0.00
September 0.313937E+09 52665438.98 0.125999E+09 74957.01 0.125924E+09 0.00 0.00
October 0.151826E+09 0.219088E+09 0.100680E+09 0.00 0.100680E+09 0.00 0.00
November 61936730.18 0.315254E+09 81179262.24 0.00 81179262.24 0.00 0.00
December 41010529.03 0.418288E+09 74571601.52 0.00 74571601.52 0.00 0.00
               
Annual Sum or Average 0.278198E+10 0.232694E+10 0.148428E+10 72604177.28 0.141167E+10 0.00 0.00
Minimum of Months 41010529.03 23724270.76 74571601.52 0.00 74571601.52 0.00 0.00
Maximum of Months 0.532932E+09 0.418288E+09 0.193172E+09 34569125.85 0.158958E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: T S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.995437E+09 0.361162E+09 0.653529E+09 0.521139E+09 0.132390E+09 0.00 0.00
February 0.517537E+09 0.314798E+09 0.380497E+09 0.258253E+09 0.122244E+09 0.00 0.00
March 0.481627E+09 0.320110E+09 0.331207E+09 0.163506E+09 0.167701E+09 0.00 0.00
April 0.553078E+09 0.163377E+09 0.296125E+09 0.126312E+09 0.169812E+09 0.00 0.00
May 0.406619E+09 0.109212E+09 0.197635E+09 32952456.36 0.164682E+09 0.00 0.00
June 0.462888E+09 35207714.38 0.164307E+09 13427492.44 0.150879E+09 0.00 0.00
July 0.472944E+09 25260459.27 0.172417E+09 17647504.23 0.154769E+09 0.00 0.00
August 0.537676E+09 35445075.25 0.211292E+09 59390576.21 0.151901E+09 0.00 0.00
September 0.624661E+09 53188832.02 0.293304E+09 0.125469E+09 0.167835E+09 0.00 0.00
October 0.808623E+09 0.215047E+09 0.482030E+09 0.333667E+09 0.148363E+09 0.00 0.00
November 0.823063E+09 0.318222E+09 0.549741E+09 0.422508E+09 0.127233E+09 0.00 0.00
December 0.893518E+09 0.421729E+09 0.610316E+09 0.482989E+09 0.127327E+09 0.00 0.00
               
Annual Sum or Average 0.757767E+10 0.237276E+10 0.434240E+10 0.255726E+10 0.178514E+10 0.00 0.00
Minimum of Months 0.406619E+09 25260459.27 0.164307E+09 13427492.44 0.122244E+09 0.00 0.00
Maximum of Months 0.995437E+09 0.421729E+09 0.653529E+09 0.521139E+09 0.169812E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: T S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.995049E+09 0.361016E+09 0.653529E+09 0.521139E+09 0.132390E+09 0.00 0.00
February 0.516944E+09 0.314965E+09 0.380497E+09 0.258253E+09 0.122244E+09 0.00 0.00
March 0.480984E+09 0.320139E+09 0.331207E+09 0.163506E+09 0.167701E+09 0.00 0.00
April 0.552576E+09 0.163335E+09 0.296125E+09 0.126312E+09 0.169812E+09 0.00 0.00
May 0.406167E+09 0.109190E+09 0.197635E+09 32952456.36 0.164682E+09 0.00 0.00
June 0.462648E+09 35187640.30 0.164307E+09 13427492.44 0.150879E+09 0.00 0.00
July 0.472738E+09 25253220.33 0.172417E+09 17647504.23 0.154769E+09 0.00 0.00
August 0.537463E+09 35444732.12 0.211292E+09 59390576.21 0.151901E+09 0.00 0.00
September 0.624499E+09 53181286.33 0.293304E+09 0.125469E+09 0.167835E+09 0.00 0.00
October 0.808205E+09 0.215039E+09 0.482030E+09 0.333667E+09 0.148363E+09 0.00 0.00
November 0.822758E+09 0.318038E+09 0.549741E+09 0.422508E+09 0.127233E+09 0.00 0.00
December 0.893068E+09 0.421735E+09 0.610316E+09 0.482989E+09 0.127327E+09 0.00 0.00
               
Annual Sum or Average 0.757310E+10 0.237252E+10 0.434240E+10 0.255726E+10 0.178514E+10 0.00 0.00
Minimum of Months 0.406167E+09 25253220.33 0.164307E+09 13427492.44 0.122244E+09 0.00 0.00
Maximum of Months 0.995049E+09 0.421735E+09 0.653529E+09 0.521139E+09 0.169812E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: T CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 51796545.10 58884566.89 40903053.76 25729878.70 15173175.05 0.00 0.00
February 41072839.70 52023802.29 36295164.92 20764357.67 15530807.25 0.00 0.00
March 64502382.38 51098569.22 50113681.88 25708662.89 24405018.99 0.00 0.00
April 0.113379E+09 26943430.34 69446852.95 41426324.01 28020528.95 0.00 0.00
May 0.129747E+09 18604752.56 74363618.79 44102717.30 30260901.49 0.00 0.00
June 0.150315E+09 6966807.97 74987257.51 46611476.30 28375781.21 0.00 0.00
July 0.132694E+09 5652189.48 65537496.83 37013680.88 28523815.96 0.00 0.00
August 0.124034E+09 7896552.56 62122436.92 35460814.07 26661622.85 0.00 0.00
September 93712657.09 10927543.08 49288266.72 23750497.53 25537769.19 0.00 0.00
October 78705255.41 36699246.17 51106921.76 31080211.33 20026710.43 0.00 0.00
November 47240932.47 52975859.54 38091454.20 22860047.23 15231406.97 0.00 0.00
December 40888213.77 68218930.67 35842995.72 21637005.84 14205989.87 0.00 0.00
               
Annual Sum or Average 0.106809E+10 0.396892E+09 0.648099E+09 0.376146E+09 0.271954E+09 0.00 0.00
Minimum of Months 40888213.77 5652189.48 35842995.72 20764357.67 14205989.87 0.00 0.00
Maximum of Months 0.150315E+09 68218930.67 74987257.51 46611476.30 30260901.49 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: G CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.150200E+09 0.180806E+09 0.121819E+09 76629982.01 45189491.35 0.00 0.00
February 0.122754E+09 0.156513E+09 0.108096E+09 61841424.63 46254609.03 0.00 0.00
March 0.193445E+09 0.149691E+09 0.149251E+09 76566796.04 72684220.06 0.00 0.00
April 0.334938E+09 86363555.90 0.206830E+09 0.123378E+09 83452108.49 0.00 0.00
May 0.379427E+09 64215246.12 0.221473E+09 0.131349E+09 90124495.47 0.00 0.00
June 0.433121E+09 28482424.21 0.223331E+09 0.138821E+09 84510138.12 0.00 0.00
July 0.379092E+09 24591118.79 0.195187E+09 0.110236E+09 84951022.45 0.00 0.00
August 0.355411E+09 33498907.01 0.185016E+09 0.105611E+09 79404947.95 0.00 0.00
September 0.267620E+09 44319049.91 0.146793E+09 70734892.27 76057832.05 0.00 0.00
October 0.225855E+09 0.122458E+09 0.152209E+09 92564604.06 59644527.58 0.00 0.00
November 0.134343E+09 0.170432E+09 0.113446E+09 68082909.68 45362920.50 0.00 0.00
December 0.114085E+09 0.219946E+09 0.106749E+09 64440388.06 42308973.19 0.00 0.00
               
Annual Sum or Average 0.309029E+10 0.128132E+10 0.193020E+10 0.112026E+10 0.809945E+09 0.00 0.00
Minimum of Months 0.114085E+09 24591118.79 0.106749E+09 61841424.63 42308973.19 0.00 0.00
Maximum of Months 0.433121E+09 0.219946E+09 0.223331E+09 0.138821E+09 90124495.47 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: M CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 47652697.20 65050350.78 40903053.76 25729878.70 15173175.05 0.00 0.00
February 37630289.01 60286793.65 36295164.92 20764357.67 15530807.25 0.00 0.00
March 60505957.62 56139983.81 50113681.88 25708662.89 24405018.99 0.00 0.00
April 0.112967E+09 28225898.52 69446852.95 41426324.01 28020528.95 0.00 0.00
May 0.130159E+09 19517383.60 74363618.79 44102717.30 30260901.49 0.00 0.00
June 0.152582E+09 7284246.27 74987257.51 46611476.30 28375781.21 0.00 0.00
July 0.135197E+09 5798692.31 65537496.83 37013680.88 28523815.96 0.00 0.00
August 0.126190E+09 8129972.00 62122436.92 35460814.07 26661622.85 0.00 0.00
September 95126843.93 11348184.49 49288266.72 23750497.53 25537769.19 0.00 0.00
October 77194958.52 39506615.36 51106921.76 31080211.33 20026710.43 0.00 0.00
November 43940625.48 58687731.37 38091454.20 22860047.23 15231406.97 0.00 0.00
December 36196285.56 77902891.26 35842995.72 21637005.84 14205989.87 0.00 0.00
               
Annual Sum or Average 0.105534E+10 0.437879E+09 0.648099E+09 0.376146E+09 0.271954E+09 0.00 0.00
Minimum of Months 36196285.56 5798692.31 35842995.72 20764357.67 14205989.87 0.00 0.00
Maximum of Months 0.152582E+09 77902891.26 74987257.51 46611476.30 30260901.49 0.00 0.00



Table of Contents

Report: AverageOutdoorConditionsMonthly

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] SITE OUTDOOR AIR WETBULB TEMPERATURE [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] SITE WIND SPEED [m/s] SITE SKY TEMPERATURE [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] SITE RAIN STATUS []
January 14.83 7.47 -0.8 2.99 -0.8 34.08 283.26 0.00
February 12.72 9.35 6.24 2.64 2.53 52.02 191.85 0.02
March 15.42 8.67 1.96 3.53 3.02 74.19 207.67 0.01
April 23.31 10.14 -4.1 3.42 6.81 72.47 350.22 0.00
May 26.31 11.07 -4.9 3.62 8.60 75.22 359.64 0.00
June 31.20 14.28 0.18 3.69 15.53 67.31 396.02 0.00
July 30.42 17.99 9.86 3.72 19.28 82.46 278.62 0.02
August 29.82 18.15 11.14 3.33 18.26 71.82 270.19 0.02
September 27.75 17.59 11.45 3.72 17.29 82.54 200.28 0.01
October 20.87 10.99 1.63 3.42 6.03 49.01 269.00 0.00
November 15.43 8.80 1.49 3.02 1.83 40.49 251.35 0.01
December 11.86 4.25 -5.9 2.21 -4.3 34.74 244.35 0.00
                 
Annual Sum or Average 21.70 11.57 2.33 3.28 7.86 61.39 275.62 0.01
Minimum of Months 11.86 4.25 -5.9 2.21 -4.3 34.08 191.85 0.00
Maximum of Months 31.20 18.15 11.45 3.72 19.28 82.54 396.02 0.02



Table of Contents

Report: OutdoorConditionsMaximumDryBulbMonthly

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January 29.00 31-JAN-15:00 10.73 -14.0 2.10 7.75 109.00 697.00
February 22.00 18-FEB-14:09 14.42 9.67 5.20 14.10 264.00 225.33
March 28.80 16-MAR-15:20 13.79 1.47 3.77 14.35 156.17 666.17
April 35.00 14-APR-14:00 14.57 -4.0 1.50 19.70 150.00 819.50
May 37.00 15-MAY-16:00 15.57 -2.0 4.60 20.75 127.50 679.00
June 42.00 16-JUN-15:00 16.74 -5.0 5.70 25.49 135.00 753.50
July 40.00 12-JUL-13:00 19.40 7.00 2.10 27.95 147.00 3.00
August 41.00 25-AUG-14:09 17.27 -0.7 3.43 25.74 162.33 768.67
September 38.30 08-SEP-14:00 19.81 10.00 3.00 25.82 142.00 699.00
October 37.00 01-OCT-12:00 19.01 9.00 4.10 27.14 262.50 136.00
November 29.00 01-NOV-14:00 16.20 8.00 2.60 16.49 73.50 907.50
December 26.00 21-DEC-14:00 10.90 -5.0 2.60 7.35 68.50 756.50
                 
Annual Sum or Average                
Minimum of Months 22.00   10.73 -14.0 1.50 7.35 68.50 3.00
Maximum of Months 42.00   19.81 10.00 5.70 27.95 264.00 907.50



Table of Contents

Report: OutdoorConditionsMinimumDryBulbMonthly

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January 0.50 01-JAN-07:00 -1.2 -3.3 3.30 -16.2 17.50 352.00
February 5.00 01-FEB-04:00 3.59 2.00 3.10 -10.7 0.00 0.00
March 0.50 26-MAR-03:00 -2.4 -6.7 2.50 -17.0 0.00 0.00
April 8.00 21-APR-03:00 0.42 -14.0 1.00 -11.7 0.00 0.00
May 12.00 01-MAY-03:00 3.97 -7.0 2.60 -6.2 0.00 0.00
June 18.00 21-JUN-04:00 8.24 -2.0 1.50 3.48 0.00 0.00
July 18.00 01-JUL-05:00 6.53 -9.0 3.10 -1.2 16.00 325.00
August 17.00 05-AUG-17:00 15.02 14.00 5.70 11.46 29.00 0.00
September 16.60 22-SEP-05:00 13.83 12.20 3.00 4.92 0.00 0.00
October 5.00 25-OCT-05:00 0.48 -6.0 3.10 -12.7 0.00 0.00
November 0.00 23-NOV-05:00 -2.5 -6.0 2.10 -17.3 0.00 0.00
December -1.1 07-DEC-04:00 -5.6 -16.0 3.10 -20.8 0.00 0.00
                 
Annual Sum or Average                
Minimum of Months -1.1   -5.6 -16.0 1.00 -20.8 0.00 0.00
Maximum of Months 18.00   15.02 14.00 5.70 11.46 29.00 352.00



Table of Contents

Report: OutdoorConditionsMaximumWetBulbMonthly

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January 16.66 08-JAN-15:00 18.00 16.00 4.60 11.46 102.00 332.00
February 14.73 18-FEB-17:00 16.00 14.00 6.20 10.50 0.00 0.00
March 15.18 17-MAR-10:00 25.50 8.30 2.50 18.46 167.50 459.00
April 15.71 11-APR-14:00 33.00 3.00 2.10 15.94 178.50 758.00
May 15.57 15-MAY-16:00 37.00 -2.0 4.60 20.75 127.50 679.00
June 23.18 17-JUN-15:00 41.00 16.00 3.60 31.13 257.00 9.00
July 23.11 13-JUL-17:00 26.00 22.00 4.60 22.13 79.00 56.50
August 22.19 16-AUG-10:00 35.00 17.00 2.10 24.33 140.50 837.00
September 22.23 01-SEP-11:00 34.40 17.20 4.60 23.82 193.50 725.50
October 21.53 01-OCT-17:00 32.00 17.00 2.10 25.33 30.50 1.50
November 18.59 12-NOV-14:00 20.00 18.00 3.10 15.39 115.00 0.00
December 12.06 12-DEC-12:00 20.00 6.00 1.50 12.60 182.50 6.00
                 
Annual Sum or Average                
Minimum of Months 12.06   16.00 -2.0 1.50 10.50 0.00 0.00
Maximum of Months 23.18   41.00 22.00 6.20 31.13 257.00 837.00



Table of Contents

Report: OutdoorConditionsMaximumDewPointMonthly

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January 16.00 08-JAN-15:00 18.00 16.66 4.60 11.46 102.00 332.00
February 14.00 18-FEB-17:00 16.00 14.73 6.20 10.50 0.00 0.00
March 13.30 06-MAR-10:00 14.40 13.70 6.10 10.69 254.50 82.00
April 8.00 15-APR-20:00 23.00 14.00 6.20 7.75 0.00 0.00
May 9.00 26-MAY-02:00 21.00 13.75 3.60 16.30 0.00 0.00
June 16.00 17-JUN-15:00 41.00 23.18 3.60 31.13 257.00 9.00
July 22.00 13-JUL-17:00 26.00 23.11 4.60 22.13 79.00 56.50
August 20.00 09-AUG-17:00 25.00 21.44 5.10 19.17 35.00 0.00
September 20.50 02-SEP-22:10 22.62 21.05 3.18 20.17 0.00 0.00
October 19.00 03-OCT-02:00 23.00 20.15 2.10 10.30 0.00 0.00
November 18.00 12-NOV-14:00 20.00 18.59 3.10 15.39 115.00 0.00
December 10.00 12-DEC-23:00 12.00 10.87 1.50 7.55 0.00 0.00
                 
Annual Sum or Average                
Minimum of Months 8.00   12.00 10.87 1.50 7.55 0.00 0.00
Maximum of Months 22.00   41.00 23.18 6.20 31.13 257.00 332.00



Table of Contents

Report: OutdoorGroundConditionsMonthly

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE GROUND TEMPERATURE [C] SITE SURFACE GROUND TEMPERATURE [C] SITE DEEP GROUND TEMPERATURE [C] SITE MAINS WATER TEMPERATURE [C] SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] SITE SNOW ON GROUND STATUS []
January 18.00 13.00 16.00 18.65 31.23 0.00
February 18.00 13.00 16.00 19.06 29.93 0.00
March 18.00 13.00 16.00 20.99 39.76 0.00
April 18.00 13.00 16.00 24.03 60.89 0.00
May 18.00 13.00 16.00 27.32 65.75 0.00
June 18.00 13.00 16.00 29.99 69.24 0.00
July 18.00 13.00 16.00 31.31 56.42 0.00
August 18.00 13.00 16.00 30.91 52.05 0.00
September 18.00 13.00 16.00 28.91 42.71 0.00
October 18.00 13.00 16.00 25.85 39.20 0.00
November 18.00 13.00 16.00 22.56 30.64 0.00
December 18.00 13.00 16.00 19.93 27.41 0.00
             
Annual Sum or Average 18.00 13.00 16.00 24.99 45.50 0.00
Minimum of Months 18.00 13.00 16.00 18.65 27.41 0.00
Maximum of Months 18.00 13.00 16.00 31.31 69.24 0.00



Table of Contents

Report: WaterHeaterReportMonthly

For: SWHSYS1 WATER HEATER

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] WATER HEATER BURNER HEATING ENERGY [] WATER HEATER GAS CONSUMPTION [] WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] WATER HEATER LOSS DEMAND ENERGY [] WATER HEATER HEAT LOSS ENERGY [J] WATER HEATER TANK TEMPERATURE [C] WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] WATER HEATER SOURCE ENERGY []
January 0.254940E+11 -0.245473E+11 0.00 0.00 744.00 0.00 -946680502.5 59.95 0.00 0.00
February 0.228349E+11 -0.219501E+11 0.00 0.00 672.00 0.00 -884816172.7 59.95 0.00 0.00
March 0.241100E+11 -0.231539E+11 0.00 0.00 744.00 0.00 -956056366.1 59.95 0.00 0.00
April 0.215216E+11 -0.206609E+11 0.00 0.00 720.00 0.00 -860662997.5 59.95 0.00 0.00
May 0.202613E+11 -0.193905E+11 0.00 0.00 744.00 0.00 -870746002.6 59.95 0.00 0.00
June 0.180426E+11 -0.172285E+11 0.00 0.00 720.00 0.00 -814042171.1 59.95 0.00 0.00
July 0.178632E+11 -0.170196E+11 0.00 0.00 744.00 0.00 -843583019.3 59.95 0.00 0.00
August 0.181031E+11 -0.172578E+11 0.00 0.00 744.00 0.00 -845310218.7 59.95 0.00 0.00
September 0.186762E+11 -0.178512E+11 0.00 0.00 720.00 0.00 -824962245.6 59.95 0.00 0.00
October 0.211554E+11 -0.202652E+11 0.00 0.00 744.00 0.00 -890199874.0 59.95 0.00 0.00
November 0.224010E+11 -0.215041E+11 0.00 0.00 720.00 0.00 -896940268.4 59.95 0.00 0.00
December 0.247472E+11 -0.237863E+11 0.00 0.00 744.00 0.00 -960866366.8 59.95 0.00 0.00
                     
Annual Sum or Average 0.255210E+12 -0.244615E+12 0.00 0.00 8760.00 0.00 -0.105949E+11 59.95 0.00 0.00
Minimum of Months 0.178632E+11 -0.245473E+11 0.00 0.00 672.00 0.00 -960866366.8 59.95 0.00 0.00
Maximum of Months 0.254940E+11 -0.170196E+11 0.00 0.00 744.00 0.00 -814042171.1 59.95 0.00 0.00



Table of Contents

Report: DaylightingReportMonthly

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER [] DAYLIGHTING LIGHTING POWER MULTIPLIER [] DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME []
January 309.83 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 241.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 344.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 380.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 403.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 418.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 399.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 361.83 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 350.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 348.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 288.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 290.67 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                       
Annual Sum or Average 4135.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 241.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 418.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GSW HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GNW HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 13582686.20 310.87 01-JAN-08:00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 13582686.20     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 13582686.20 310.87   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT OFFICE HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 167757.21 1197.91 27-MAR-06:01 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 167757.21     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 167757.21 1197.91   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GNE HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 14861292.93 317.99 01-JAN-05:00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 14861292.93     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 14861292.93 317.99   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GN1 HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 560798.29 66.08 01-JAN-08:00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 560798.29     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 560798.29 66.08   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GN2 HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 665364.38 70.41 01-JAN-08:00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 665364.38     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 665364.38 70.41   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GS1 HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GS2 HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MSW HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MNW HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 3965964.48 299.01 01-JAN-08:00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 3821860.16 233.85 07-DEC-06:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 7787824.64     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 3965964.48 299.01   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MSE HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MNE HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 6811867.76 360.03 01-JAN-06:00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 2282770.23 216.64 07-DEC-06:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 9094637.99     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 6811867.76 360.03   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MN1 HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MN2 HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MS1 HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MS2 HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TSW HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 28979852.31 727.09 01-JAN-07:00 0.00 0.00 0.00 0.00 0.00
February 41713229.35 465.34 13-FEB-06:00 0.00 0.00 0.00 0.00 0.00
March 47071939.93 760.95 26-MAR-06:00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 19771497.23 646.28 24-NOV-07:00 0.00 0.00 0.00 0.00 0.00
December 0.191958E+09 1039.28 07-DEC-06:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.329495E+09     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.191958E+09 1039.28   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TNW HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.141747E+09 1015.62 01-JAN-08:00 0.00 0.00 0.00 0.00 0.00
February 0.161058E+09 598.08 09-FEB-07:00 0.00 0.00 0.00 0.00 0.00
March 89234637.57 865.96 26-MAR-06:00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 7050654.70 326.23 26-OCT-05:00 0.00 0.00 0.00 0.00 0.00
November 0.104839E+09 909.71 24-NOV-06:00 0.00 0.00 0.00 0.00 0.00
December 0.537055E+09 1346.61 07-DEC-06:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.104098E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.537055E+09 1346.61   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TSE HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 28678016.99 745.43 01-JAN-07:00 0.00 0.00 0.00 0.00 0.00
February 38910412.98 506.21 05-FEB-04:00 0.00 0.00 0.00 0.00 0.00
March 42259588.92 774.55 26-MAR-06:00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 18716972.52 662.18 24-NOV-07:00 0.00 0.00 0.00 0.00 0.00
December 0.181223E+09 1045.41 07-DEC-06:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.309788E+09     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.181223E+09 1045.41   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TNE HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.138503E+09 1024.44 01-JAN-07:00 0.00 0.00 0.00 0.00 0.00
February 0.143523E+09 650.86 05-FEB-04:00 0.00 0.00 0.00 0.00 0.00
March 81663096.18 875.94 26-MAR-06:00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 5096511.69 300.61 26-OCT-06:00 0.00 0.00 0.00 0.00 0.00
November 97154861.94 946.50 24-NOV-06:00 0.00 0.00 0.00 0.00 0.00
December 0.503026E+09 1368.81 07-DEC-06:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.968966E+09     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.503026E+09 1368.81   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TN1 HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 50007952.81 653.16 01-JAN-08:00 0.00 0.00 0.00 0.00 0.00
February 47308622.07 341.59 05-FEB-04:00 0.00 0.00 0.00 0.00 0.00
March 28201798.12 497.73 27-MAR-06:00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 49224.93 33.75 26-OCT-07:02 0.00 0.00 0.00 0.00 0.00
November 30882628.92 582.95 24-NOV-06:00 0.00 0.00 0.00 0.00 0.00
December 0.273518E+09 923.02 07-DEC-06:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.429968E+09     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.273518E+09 923.02   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TN2 HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 51025858.60 657.55 01-JAN-08:00 0.00 0.00 0.00 0.00 0.00
February 47118773.20 348.66 05-FEB-04:00 0.00 0.00 0.00 0.00 0.00
March 28212617.94 497.60 27-MAR-06:00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 31376566.43 586.75 24-NOV-06:00 0.00 0.00 0.00 0.00 0.00
December 0.273904E+09 924.90 07-DEC-06:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.431638E+09     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.273904E+09 924.90   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TS1 HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 7766327.30 355.81 01-JAN-07:00 0.00 0.00 0.00 0.00 0.00
February 4354363.09 174.41 05-FEB-07:00 0.00 0.00 0.00 0.00 0.00
March 9236182.65 376.44 26-MAR-06:00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 3547409.95 293.69 24-NOV-07:00 0.00 0.00 0.00 0.00 0.00
December 53917735.26 582.76 07-DEC-06:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 78822018.25     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 53917735.26 582.76   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TS2 HEATING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 7840144.50 357.49 01-JAN-07:00 0.00 0.00 0.00 0.00 0.00
February 4477494.58 180.83 05-FEB-07:00 0.00 0.00 0.00 0.00 0.00
March 9224889.19 376.73 26-MAR-06:00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 3588686.01 295.38 24-NOV-07:00 0.00 0.00 0.00 0.00 0.00
December 53559084.17 581.59 07-DEC-06:00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 78690298.45     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 53559084.17 581.59   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GSW_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GNW_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT OFFICE_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GNE_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GN1_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GN2_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GS1_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GS2_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MSW_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MNW_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MSE_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MNE_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MN1_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MN2_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MS1_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MS2_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TSW_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TNW_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TSE_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TNE_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TN1_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TN2_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TS1_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TS2_SUPPHEATCOIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GSW HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.103163E+10 0.102640E+10 5971.49 08-JAN-20:12 4556.69 0.00
February 0.00 0.00 0.183011E+09 0.182350E+09 5563.83 24-FEB-17:01 5563.83 0.00
March 0.00 0.00 0.308628E+09 0.307874E+09 5643.36 18-MAR-10:12 5582.05 0.00
April 0.00 0.00 0.197846E+10 0.197831E+10 5610.61 16-APR-11:12 5610.61 0.00
May 0.00 0.00 0.226249E+10 0.226249E+10 5556.42 11-MAY-07:32 5556.42 0.00
June 0.00 0.00 0.332115E+10 0.331610E+10 5587.66 04-JUN-06:42 5587.66 0.00
July 0.00 0.00 0.404210E+10 0.374527E+10 6021.19 15-JUL-06:42 4473.10 0.00
August 0.00 0.00 0.409925E+10 0.381091E+10 6031.61 05-AUG-21:52 4480.56 0.00
September 0.00 0.00 0.406857E+10 0.378379E+10 6250.49 03-SEP-10:42 3693.49 0.00
October 0.00 0.00 0.270895E+10 0.265300E+10 5943.88 03-OCT-07:22 4730.85 0.00
November 0.00 0.00 0.163283E+10 0.158552E+10 6218.68 12-NOV-22:52 3841.35 0.00
December 0.00 0.00 0.925447E+09 0.925348E+09 5569.84 13-DEC-17:01 5569.84 0.00
                 
Annual Sum or Average 0.00 0.00 0.265625E+11 0.255774E+11       0.00
Minimum of Months 0.00 0.00 0.183011E+09 0.182350E+09 5556.42   3693.49 0.00
Maximum of Months 0.00 0.00 0.409925E+10 0.381091E+10 6250.49   5610.61 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GNW HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.125760E+09 0.125291E+09 5334.73 26-JAN-14:42 5334.73 0.00
February 0.00 0.00 3390549.46 3390549.46 3131.84 01-FEB-17:12 3131.84 0.00
March 0.00 0.00 0.137931E+09 0.137910E+09 5443.90 17-MAR-21:52 5443.90 0.00
April 0.00 0.00 0.162594E+10 0.162585E+10 5482.39 16-APR-21:32 5482.39 0.00
May 0.00 0.00 0.239466E+10 0.239466E+10 5435.55 11-MAY-08:62 5435.55 0.00
June 0.00 0.00 0.367754E+10 0.367239E+10 5491.48 04-JUN-06:42 5491.48 0.00
July 0.00 0.00 0.426956E+10 0.395672E+10 5960.86 15-JUL-06:42 4268.13 0.00
August 0.00 0.00 0.413620E+10 0.382973E+10 5984.06 05-AUG-21:52 4231.87 0.00
September 0.00 0.00 0.378105E+10 0.348751E+10 6138.39 03-SEP-11:22 3719.17 0.00
October 0.00 0.00 0.190791E+10 0.185275E+10 5875.42 03-OCT-08:62 4440.02 0.00
November 0.00 0.00 0.651917E+09 0.616664E+09 6085.35 12-NOV-22:52 3798.34 0.00
December 0.00 0.00 88818552.31 88815436.13 5332.34 27-DEC-19:02 5332.34 0.00
                 
Annual Sum or Average 0.00 0.00 0.228007E+11 0.217917E+11       0.00
Minimum of Months 0.00 0.00 3390549.46 3390549.46 3131.84   3131.84 0.00
Maximum of Months 0.00 0.00 0.426956E+10 0.395672E+10 6138.39   5491.48 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT OFFICE HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.112513E+10 0.112209E+10 6285.69 17-JAN-07:01 6285.69 0.00
February 0.00 0.00 0.466751E+09 0.455844E+09 1952.21 01-FEB-14:00 1952.21 0.00
March 0.00 0.00 0.681168E+09 0.678119E+09 5908.99 21-MAR-06:01 5908.99 0.00
April 0.00 0.00 0.183781E+10 0.183781E+10 6637.01 25-APR-06:01 6637.01 0.00
May 0.00 0.00 0.231068E+10 0.231068E+10 6674.36 11-MAY-06:01 6674.36 0.00
June 0.00 0.00 0.331500E+10 0.331255E+10 6795.00 30-JUN-06:01 6795.00 0.00
July 0.00 0.00 0.362041E+10 0.339380E+10 7676.35 14-JUL-06:01 4593.64 0.00
August 0.00 0.00 0.401077E+10 0.377256E+10 7418.50 01-AUG-06:01 5689.56 0.00
September 0.00 0.00 0.352539E+10 0.329835E+10 7397.06 05-SEP-06:01 5721.22 0.00
October 0.00 0.00 0.250212E+10 0.245946E+10 7393.28 03-OCT-06:01 5602.07 0.00
November 0.00 0.00 0.158785E+10 0.155808E+10 7032.97 14-NOV-07:01 5344.24 0.00
December 0.00 0.00 0.870557E+09 0.869424E+09 6285.69 26-DEC-07:01 6285.69 0.00
                 
Annual Sum or Average 0.00 0.00 0.258536E+11 0.250688E+11       0.00
Minimum of Months 0.00 0.00 0.466751E+09 0.455844E+09 1952.21   1952.21 0.00
Maximum of Months 0.00 0.00 0.401077E+10 0.377256E+10 7676.35   6795.00 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GNE HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.107937E+09 0.107465E+09 4959.90 26-JAN-14:42 4959.90 0.00
February 0.00 0.00 2938571.95 2938571.95 1303.42 01-FEB-17:12 1303.42 0.00
March 0.00 0.00 0.136082E+09 0.136045E+09 5101.73 18-MAR-11:32 5101.73 0.00
April 0.00 0.00 0.163310E+10 0.163301E+10 5109.57 16-APR-12:22 5109.57 0.00
May 0.00 0.00 0.243412E+10 0.243412E+10 5073.61 11-MAY-08:62 5073.61 0.00
June 0.00 0.00 0.372564E+10 0.372032E+10 5102.59 04-JUN-06:42 5102.59 0.00
July 0.00 0.00 0.440104E+10 0.408257E+10 5535.70 15-JUL-06:42 3973.95 0.00
August 0.00 0.00 0.425704E+10 0.394422E+10 5559.34 05-AUG-21:52 3934.50 0.00
September 0.00 0.00 0.384205E+10 0.354343E+10 5701.32 03-SEP-11:22 3461.41 0.00
October 0.00 0.00 0.194297E+10 0.188632E+10 5451.33 03-OCT-08:62 4147.86 0.00
November 0.00 0.00 0.616017E+09 0.582459E+09 5650.85 12-NOV-22:52 3519.34 0.00
December 0.00 0.00 87060013.66 87020326.51 4940.24 27-DEC-19:02 4940.24 0.00
                 
Annual Sum or Average 0.00 0.00 0.231860E+11 0.221599E+11       0.00
Minimum of Months 0.00 0.00 2938571.95 2938571.95 1303.42   1303.42 0.00
Maximum of Months 0.00 0.00 0.440104E+10 0.408257E+10 5701.32   5109.57 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GN1 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.164710E+09 0.163472E+09 4651.23 08-JAN-20:12 3432.54 0.00
February 0.00 0.00 8895695.91 8846633.50 2536.85 01-FEB-17:12 2536.85 0.00
March 0.00 0.00 0.167455E+09 0.167359E+09 4365.36 18-MAR-11:32 4365.36 0.00
April 0.00 0.00 0.138027E+10 0.138016E+10 4360.41 16-APR-12:22 4360.41 0.00
May 0.00 0.00 0.203289E+10 0.203289E+10 4334.32 11-MAY-08:62 4334.32 0.00
June 0.00 0.00 0.299190E+10 0.298702E+10 4374.38 04-JUN-06:42 4374.38 0.00
July 0.00 0.00 0.356081E+10 0.326998E+10 4751.70 15-JUL-06:42 3386.69 0.00
August 0.00 0.00 0.342963E+10 0.314346E+10 4766.49 05-AUG-21:52 3375.22 0.00
September 0.00 0.00 0.315381E+10 0.288107E+10 4892.45 03-SEP-11:22 2955.35 0.00
October 0.00 0.00 0.167166E+10 0.161915E+10 4686.39 03-OCT-08:62 3519.74 0.00
November 0.00 0.00 0.675608E+09 0.639275E+09 4855.84 12-NOV-22:52 3056.53 0.00
December 0.00 0.00 0.147343E+09 0.147256E+09 4259.57 03-DEC-19:12 4259.57 0.00
                 
Annual Sum or Average 0.00 0.00 0.193850E+11 0.184400E+11       0.00
Minimum of Months 0.00 0.00 8895695.91 8846633.50 2536.85   2536.85 0.00
Maximum of Months 0.00 0.00 0.356081E+10 0.326998E+10 4892.45   4374.38 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GN2 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.164940E+09 0.163733E+09 4643.44 08-JAN-20:12 3425.10 0.00
February 0.00 0.00 9274635.82 9208305.05 2534.88 01-FEB-17:12 2534.88 0.00
March 0.00 0.00 0.169421E+09 0.169322E+09 4359.24 18-MAR-11:32 4359.24 0.00
April 0.00 0.00 0.138649E+10 0.138638E+10 4355.28 16-APR-12:22 4355.28 0.00
May 0.00 0.00 0.203884E+10 0.203884E+10 4328.11 11-MAY-08:62 4328.11 0.00
June 0.00 0.00 0.299512E+10 0.299024E+10 4367.57 04-JUN-06:42 4367.57 0.00
July 0.00 0.00 0.356666E+10 0.327560E+10 4744.23 15-JUL-06:42 3382.00 0.00
August 0.00 0.00 0.343552E+10 0.314909E+10 4758.89 05-AUG-21:52 3370.10 0.00
September 0.00 0.00 0.315757E+10 0.288465E+10 4884.66 03-SEP-11:22 2950.95 0.00
October 0.00 0.00 0.167707E+10 0.162448E+10 4678.80 03-OCT-08:62 3514.78 0.00
November 0.00 0.00 0.672475E+09 0.636134E+09 4848.03 12-NOV-22:52 3051.04 0.00
December 0.00 0.00 0.148031E+09 0.147940E+09 4252.98 03-DEC-19:12 4252.98 0.00
                 
Annual Sum or Average 0.00 0.00 0.194214E+11 0.184756E+11       0.00
Minimum of Months 0.00 0.00 9274635.82 9208305.05 2534.88   2534.88 0.00
Maximum of Months 0.00 0.00 0.356666E+10 0.327560E+10 4884.66   4367.57 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GS1 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.132448E+10 0.131722E+10 4779.81 08-JAN-20:12 3705.60 0.00
February 0.00 0.00 0.401953E+09 0.393212E+09 4614.86 18-FEB-19:12 3980.24 0.00
March 0.00 0.00 0.466074E+09 0.463178E+09 4522.35 18-MAR-10:12 4515.50 0.00
April 0.00 0.00 0.178497E+10 0.178477E+10 4485.62 16-APR-11:12 4485.62 0.00
May 0.00 0.00 0.194856E+10 0.194856E+10 4445.90 11-MAY-07:32 4445.90 0.00
June 0.00 0.00 0.268904E+10 0.268416E+10 4464.20 04-JUN-06:42 4464.20 0.00
July 0.00 0.00 0.339291E+10 0.311568E+10 4823.85 15-JUL-06:42 3528.84 0.00
August 0.00 0.00 0.345835E+10 0.318774E+10 4816.70 05-AUG-21:52 3584.74 0.00
September 0.00 0.00 0.350120E+10 0.323428E+10 4996.44 03-SEP-10:42 2944.22 0.00
October 0.00 0.00 0.252154E+10 0.246745E+10 4749.24 03-OCT-07:22 3776.06 0.00
November 0.00 0.00 0.173782E+10 0.168889E+10 4956.27 12-NOV-22:52 3085.38 0.00
December 0.00 0.00 0.124236E+10 0.124192E+10 4444.04 13-DEC-17:01 4444.04 0.00
                 
Annual Sum or Average 0.00 0.00 0.244693E+11 0.235271E+11       0.00
Minimum of Months 0.00 0.00 0.401953E+09 0.393212E+09 4444.04   2944.22 0.00
Maximum of Months 0.00 0.00 0.350120E+10 0.323428E+10 4996.44   4515.50 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT GS2 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.131911E+10 0.131186E+10 4877.22 08-JAN-20:12 3799.03 0.00
February 0.00 0.00 0.390982E+09 0.382448E+09 4713.35 18-FEB-19:12 4067.91 0.00
March 0.00 0.00 0.475441E+09 0.472552E+09 4619.41 18-MAR-10:12 4617.23 0.00
April 0.00 0.00 0.190146E+10 0.190124E+10 4578.06 16-APR-11:12 4578.06 0.00
May 0.00 0.00 0.210948E+10 0.210948E+10 4543.45 11-MAY-07:32 4543.45 0.00
June 0.00 0.00 0.290878E+10 0.290373E+10 4559.04 04-JUN-06:42 4559.04 0.00
July 0.00 0.00 0.366895E+10 0.338351E+10 4903.59 15-JUL-06:42 3676.01 0.00
August 0.00 0.00 0.370086E+10 0.342288E+10 4913.49 05-AUG-21:52 3679.03 0.00
September 0.00 0.00 0.373757E+10 0.346334E+10 5083.13 03-SEP-10:42 3062.24 0.00
October 0.00 0.00 0.266778E+10 0.261185E+10 4841.79 03-OCT-07:22 3882.20 0.00
November 0.00 0.00 0.176278E+10 0.171327E+10 5059.58 12-NOV-22:52 3154.19 0.00
December 0.00 0.00 0.122901E+10 0.122858E+10 4536.75 13-DEC-17:01 4536.75 0.00
                 
Annual Sum or Average 0.00 0.00 0.258722E+11 0.249047E+11       0.00
Minimum of Months 0.00 0.00 0.390982E+09 0.382448E+09 4536.75   3062.24 0.00
Maximum of Months 0.00 0.00 0.373757E+10 0.346334E+10 5083.13   4617.23 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MSW HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.306607E+10 0.305348E+10 13581.09 08-JAN-20:12 10644.60 0.00
February 0.00 0.00 0.143317E+10 0.139038E+10 13228.33 18-FEB-19:12 11509.32 0.00
March 0.00 0.00 0.198375E+10 0.197240E+10 12896.74 05-MAR-22:52 12613.94 0.00
April 0.00 0.00 0.548738E+10 0.548708E+10 12761.07 16-APR-11:12 12761.07 0.00
May 0.00 0.00 0.609659E+10 0.609659E+10 12652.38 11-MAY-07:32 12652.38 0.00
June 0.00 0.00 0.782072E+10 0.781036E+10 12713.82 04-JUN-06:42 12713.82 0.00
July 0.00 0.00 0.827522E+10 0.766817E+10 13803.58 15-JUL-06:42 9876.12 0.00
August 0.00 0.00 0.803843E+10 0.745923E+10 13839.43 05-AUG-20:52 9793.96 0.00
September 0.00 0.00 0.742771E+10 0.687260E+10 14335.63 03-SEP-10:42 8168.42 0.00
October 0.00 0.00 0.494581E+10 0.484067E+10 13679.68 03-OCT-07:22 10294.04 0.00
November 0.00 0.00 0.300771E+10 0.292367E+10 14002.98 13-NOV-22:52 9175.33 0.00
December 0.00 0.00 0.193805E+10 0.193801E+10 12698.89 13-DEC-17:01 12698.89 0.00
                 
Annual Sum or Average 0.00 0.00 0.595206E+11 0.575126E+11       0.00
Minimum of Months 0.00 0.00 0.143317E+10 0.139038E+10 12652.38   8168.42 0.00
Maximum of Months 0.00 0.00 0.827522E+10 0.781036E+10 14335.63   12761.07 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MNW HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.647220E+09 0.641456E+09 13396.19 08-JAN-20:12 10032.75 0.00
February 0.00 0.00 0.235888E+09 0.223702E+09 12958.84 18-FEB-19:12 11251.03 0.00
March 0.00 0.00 0.109441E+10 0.108819E+10 12659.91 05-MAR-22:52 12300.44 0.00
April 0.00 0.00 0.470639E+10 0.470617E+10 12533.83 16-APR-12:22 12533.83 0.00
May 0.00 0.00 0.634037E+10 0.634037E+10 12433.87 11-MAY-08:62 12433.87 0.00
June 0.00 0.00 0.848760E+10 0.847683E+10 12536.27 04-JUN-06:42 12536.27 0.00
July 0.00 0.00 0.865876E+10 0.801895E+10 13644.44 15-JUL-06:42 9530.73 0.00
August 0.00 0.00 0.799320E+10 0.737933E+10 13680.20 04-AUG-09:12 9454.44 0.00
September 0.00 0.00 0.673827E+10 0.616818E+10 14072.82 03-SEP-11:22 8207.47 0.00
October 0.00 0.00 0.320386E+10 0.310277E+10 13497.44 03-OCT-08:62 9718.09 0.00
November 0.00 0.00 0.995074E+09 0.937609E+09 13756.38 12-NOV-22:52 8733.28 0.00
December 0.00 0.00 0.168450E+09 0.168449E+09 12169.28 26-DEC-21:32 12169.28 0.00
                 
Annual Sum or Average 0.00 0.00 0.492695E+11 0.472520E+11       0.00
Minimum of Months 0.00 0.00 0.168450E+09 0.168449E+09 12169.28   8207.47 0.00
Maximum of Months 0.00 0.00 0.865876E+10 0.847683E+10 14072.82   12536.27 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MSE HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.300877E+10 0.299566E+10 12477.51 08-JAN-20:12 9746.81 0.00
February 0.00 0.00 0.152261E+10 0.147273E+10 12178.25 18-FEB-19:12 10589.61 0.00
March 0.00 0.00 0.203338E+10 0.202042E+10 11868.06 05-MAR-22:52 11655.19 0.00
April 0.00 0.00 0.549194E+10 0.549163E+10 11734.01 16-APR-12:32 11734.01 0.00
May 0.00 0.00 0.612587E+10 0.612587E+10 11634.02 11-MAY-07:32 11634.02 0.00
June 0.00 0.00 0.787163E+10 0.786097E+10 11680.68 04-JUN-06:42 11680.68 0.00
July 0.00 0.00 0.852174E+10 0.789954E+10 12668.44 15-JUL-06:42 9095.87 0.00
August 0.00 0.00 0.825606E+10 0.766191E+10 12717.10 05-AUG-20:52 9023.38 0.00
September 0.00 0.00 0.753640E+10 0.696873E+10 13169.82 03-SEP-10:42 7512.27 0.00
October 0.00 0.00 0.501703E+10 0.490882E+10 12540.24 03-OCT-07:22 9526.55 0.00
November 0.00 0.00 0.293145E+10 0.285335E+10 12825.95 12-NOV-22:52 8154.11 0.00
December 0.00 0.00 0.194694E+10 0.194683E+10 11625.58 13-DEC-17:01 11625.58 0.00
                 
Annual Sum or Average 0.00 0.00 0.602638E+11 0.582065E+11       0.00
Minimum of Months 0.00 0.00 0.152261E+10 0.147273E+10 11625.58   7512.27 0.00
Maximum of Months 0.00 0.00 0.852174E+10 0.789954E+10 13169.82   11734.01 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MNE HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.586762E+09 0.580523E+09 12280.75 08-JAN-20:12 9166.49 0.00
February 0.00 0.00 0.301896E+09 0.282814E+09 11901.12 18-FEB-19:12 10397.64 0.00
March 0.00 0.00 0.113729E+10 0.112942E+10 11637.04 05-MAR-22:52 11375.14 0.00
April 0.00 0.00 0.471693E+10 0.471670E+10 11516.04 16-APR-12:22 11516.04 0.00
May 0.00 0.00 0.642284E+10 0.642284E+10 11430.85 11-MAY-08:62 11430.85 0.00
June 0.00 0.00 0.859056E+10 0.857940E+10 11501.95 04-JUN-06:42 11501.95 0.00
July 0.00 0.00 0.894486E+10 0.829125E+10 12531.87 15-JUL-06:42 8793.58 0.00
August 0.00 0.00 0.825334E+10 0.762277E+10 12545.60 04-AUG-09:12 8737.20 0.00
September 0.00 0.00 0.686847E+10 0.628475E+10 12912.22 03-SEP-11:22 7550.81 0.00
October 0.00 0.00 0.327606E+10 0.316978E+10 12388.23 03-OCT-08:62 9051.83 0.00
November 0.00 0.00 0.903581E+09 0.850791E+09 12609.06 12-NOV-22:52 7955.36 0.00
December 0.00 0.00 0.155636E+09 0.155585E+09 11130.43 27-DEC-19:02 11130.43 0.00
                 
Annual Sum or Average 0.00 0.00 0.501582E+11 0.480866E+11       0.00
Minimum of Months 0.00 0.00 0.155636E+09 0.155585E+09 11130.43   7550.81 0.00
Maximum of Months 0.00 0.00 0.894486E+10 0.857940E+10 12912.22   11516.04 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MN1 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.846795E+09 0.837594E+09 10548.17 08-JAN-20:12 7972.64 0.00
February 0.00 0.00 0.602808E+09 0.561884E+09 10204.86 18-FEB-19:12 8974.63 0.00
March 0.00 0.00 0.125582E+10 0.124409E+10 10035.16 06-MAR-18:42 9294.01 0.00
April 0.00 0.00 0.373669E+10 0.373646E+10 9844.15 16-APR-12:22 9844.15 0.00
May 0.00 0.00 0.498633E+10 0.498633E+10 9770.47 11-MAY-08:62 9770.47 0.00
June 0.00 0.00 0.651918E+10 0.650920E+10 9851.29 04-JUN-06:42 9851.29 0.00
July 0.00 0.00 0.698941E+10 0.640539E+10 10728.65 15-JUL-06:42 7452.82 0.00
August 0.00 0.00 0.648185E+10 0.591531E+10 10750.08 04-AUG-09:12 7423.45 0.00
September 0.00 0.00 0.561012E+10 0.508272E+10 11064.58 03-SEP-11:22 6448.67 0.00
October 0.00 0.00 0.286629E+10 0.276881E+10 10611.94 03-OCT-08:62 7631.96 0.00
November 0.00 0.00 0.114005E+10 0.107395E+10 10841.20 12-NOV-22:52 6976.87 0.00
December 0.00 0.00 0.331959E+09 0.331684E+09 9599.59 03-DEC-19:12 9599.59 0.00
                 
Annual Sum or Average 0.00 0.00 0.413673E+11 0.394534E+11       0.00
Minimum of Months 0.00 0.00 0.331959E+09 0.331684E+09 9599.59   6448.67 0.00
Maximum of Months 0.00 0.00 0.698941E+10 0.650920E+10 11064.58   9851.29 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MN2 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.843369E+09 0.834232E+09 10528.62 08-JAN-20:12 7954.26 0.00
February 0.00 0.00 0.612864E+09 0.571340E+09 10187.88 18-FEB-19:12 8963.99 0.00
March 0.00 0.00 0.126402E+10 0.125212E+10 10017.55 06-MAR-18:42 9279.11 0.00
April 0.00 0.00 0.375116E+10 0.375093E+10 9829.87 16-APR-12:22 9829.87 0.00
May 0.00 0.00 0.500028E+10 0.500028E+10 9754.43 11-MAY-08:62 9754.43 0.00
June 0.00 0.00 0.652615E+10 0.651616E+10 9834.10 04-JUN-06:42 9834.10 0.00
July 0.00 0.00 0.700082E+10 0.641634E+10 10710.00 15-JUL-06:42 7439.56 0.00
August 0.00 0.00 0.649369E+10 0.592653E+10 10731.23 04-AUG-09:12 7411.88 0.00
September 0.00 0.00 0.561876E+10 0.509085E+10 11045.11 03-SEP-11:22 6438.08 0.00
October 0.00 0.00 0.287671E+10 0.277905E+10 10593.46 03-OCT-08:62 7621.60 0.00
November 0.00 0.00 0.113574E+10 0.107019E+10 10821.02 12-NOV-22:52 6959.02 0.00
December 0.00 0.00 0.334148E+09 0.333863E+09 9583.30 03-DEC-19:12 9583.30 0.00
                 
Annual Sum or Average 0.00 0.00 0.414577E+11 0.395419E+11       0.00
Minimum of Months 0.00 0.00 0.334148E+09 0.333863E+09 9583.30   6438.08 0.00
Maximum of Months 0.00 0.00 0.700082E+10 0.651616E+10 11045.11   9834.10 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MS1 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.354885E+10 0.353291E+10 10702.27 08-JAN-20:12 8466.70 0.00
February 0.00 0.00 0.208045E+10 0.200694E+10 10456.54 18-FEB-19:12 9191.34 0.00
March 0.00 0.00 0.226842E+10 0.225170E+10 10220.82 06-MAR-18:42 9668.44 0.00
April 0.00 0.00 0.457557E+10 0.457520E+10 10070.87 16-APR-11:12 10070.87 0.00
May 0.00 0.00 0.481896E+10 0.481896E+10 9984.95 11-MAY-07:32 9984.95 0.00
June 0.00 0.00 0.593640E+10 0.592661E+10 10019.20 04-JUN-06:42 10019.20 0.00
July 0.00 0.00 0.669057E+10 0.613473E+10 10886.91 15-JUL-06:42 7778.12 0.00
August 0.00 0.00 0.661619E+10 0.607946E+10 10920.44 05-AUG-20:52 7767.11 0.00
September 0.00 0.00 0.637584E+10 0.585761E+10 11307.89 03-SEP-10:42 6447.03 0.00
October 0.00 0.00 0.470040E+10 0.459799E+10 10777.62 03-OCT-07:22 8169.32 0.00
November 0.00 0.00 0.338293E+10 0.329384E+10 11050.49 12-NOV-22:52 7168.78 0.00
December 0.00 0.00 0.270908E+10 0.270831E+10 10015.72 13-DEC-17:01 10015.72 0.00
                 
Annual Sum or Average 0.00 0.00 0.537037E+11 0.517843E+11       0.00
Minimum of Months 0.00 0.00 0.208045E+10 0.200694E+10 9984.95   6447.03 0.00
Maximum of Months 0.00 0.00 0.669057E+10 0.613473E+10 11307.89   10070.87 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT MS2 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.355293E+10 0.353697E+10 10685.62 08-JAN-20:12 8453.11 0.00
February 0.00 0.00 0.209446E+10 0.202057E+10 10441.16 18-FEB-19:12 9181.63 0.00
March 0.00 0.00 0.228316E+10 0.226606E+10 10205.22 06-MAR-18:42 9655.78 0.00
April 0.00 0.00 0.459436E+10 0.459400E+10 10055.19 16-APR-11:12 10055.19 0.00
May 0.00 0.00 0.483823E+10 0.483823E+10 9969.92 11-MAY-07:32 9969.92 0.00
June 0.00 0.00 0.594992E+10 0.594013E+10 10003.79 04-JUN-06:42 10003.79 0.00
July 0.00 0.00 0.670735E+10 0.615084E+10 10869.91 15-JUL-06:42 7768.07 0.00
August 0.00 0.00 0.663355E+10 0.609614E+10 10903.13 05-AUG-20:52 7755.60 0.00
September 0.00 0.00 0.638724E+10 0.586853E+10 11290.29 03-SEP-10:42 6437.81 0.00
October 0.00 0.00 0.471524E+10 0.461267E+10 10760.31 03-OCT-07:22 8157.89 0.00
November 0.00 0.00 0.338362E+10 0.329481E+10 11032.98 13-NOV-17:01 7321.12 0.00
December 0.00 0.00 0.271847E+10 0.271771E+10 9999.63 13-DEC-17:01 9999.63 0.00
                 
Annual Sum or Average 0.00 0.00 0.538585E+11 0.519367E+11       0.00
Minimum of Months 0.00 0.00 0.209446E+10 0.202057E+10 9969.92   6437.81 0.00
Maximum of Months 0.00 0.00 0.670735E+10 0.615084E+10 11290.29   10055.19 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TSW HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.963442E+09 0.961751E+09 7823.16 08-JAN-20:12 5831.28 0.00
February 0.00 0.00 0.284162E+09 0.282402E+09 7630.13 18-FEB-19:12 6500.15 0.00
March 0.00 0.00 0.633698E+09 0.632818E+09 7425.98 18-MAR-10:12 7425.98 0.00
April 0.00 0.00 0.276292E+10 0.276290E+10 7417.57 16-APR-13:22 7417.57 0.00
May 0.00 0.00 0.328171E+10 0.328171E+10 7252.14 11-MAY-07:32 7252.14 0.00
June 0.00 0.00 0.451607E+10 0.451085E+10 7334.68 04-JUN-06:42 7334.68 0.00
July 0.00 0.00 0.471122E+10 0.440076E+10 8048.10 15-JUL-06:42 5463.07 0.00
August 0.00 0.00 0.449993E+10 0.421116E+10 8000.45 05-AUG-09:12 5562.84 0.00
September 0.00 0.00 0.399719E+10 0.372084E+10 8285.66 03-SEP-10:42 4736.83 0.00
October 0.00 0.00 0.223401E+10 0.218754E+10 7941.78 03-OCT-07:22 5644.02 0.00
November 0.00 0.00 0.932336E+09 0.914684E+09 8047.56 13-NOV-22:52 5160.46 0.00
December 0.00 0.00 0.485611E+09 0.485611E+09 7334.60 13-DEC-17:01 7334.60 0.00
                 
Annual Sum or Average 0.00 0.00 0.293023E+11 0.283530E+11       0.00
Minimum of Months 0.00 0.00 0.284162E+09 0.282402E+09 7252.14   4736.83 0.00
Maximum of Months 0.00 0.00 0.471122E+10 0.451085E+10 8285.66   7425.98 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TNW HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.136376E+09 0.136114E+09 6250.73 26-JAN-14:42 6250.73 0.00
February 0.00 0.00 7560207.70 7497812.87 5960.92 22-FEB-20:32 5960.92 0.00
March 0.00 0.00 0.343289E+09 0.343080E+09 7392.27 11-MAR-18:52 7356.04 0.00
April 0.00 0.00 0.237952E+10 0.237951E+10 7324.34 16-APR-12:22 7324.34 0.00
May 0.00 0.00 0.341796E+10 0.341796E+10 7252.37 11-MAY-08:62 7252.37 0.00
June 0.00 0.00 0.489424E+10 0.488862E+10 7328.90 04-JUN-06:42 7328.90 0.00
July 0.00 0.00 0.494963E+10 0.461757E+10 8035.58 15-JUL-06:42 5449.29 0.00
August 0.00 0.00 0.450120E+10 0.418901E+10 8015.79 04-AUG-09:12 5505.27 0.00
September 0.00 0.00 0.366265E+10 0.337664E+10 8232.01 03-SEP-11:22 4843.25 0.00
October 0.00 0.00 0.144161E+10 0.139505E+10 7923.24 03-OCT-08:62 5593.21 0.00
November 0.00 0.00 0.244062E+09 0.235889E+09 7937.51 11-NOV-22:52 5613.73 0.00
December 0.00 0.00 24640577.03 24640577.03 2386.93 24-DEC-14:43 2386.93 0.00
                 
Annual Sum or Average 0.00 0.00 0.260027E+11 0.250116E+11       0.00
Minimum of Months 0.00 0.00 7560207.70 7497812.87 2386.93   2386.93 0.00
Maximum of Months 0.00 0.00 0.494963E+10 0.488862E+10 8232.01   7356.04 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TSE HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.901369E+09 0.899545E+09 7017.24 08-JAN-20:12 5182.53 0.00
February 0.00 0.00 0.279830E+09 0.276641E+09 6858.18 18-FEB-19:12 5859.51 0.00
March 0.00 0.00 0.612670E+09 0.611593E+09 6757.94 18-MAR-11:02 6757.94 0.00
April 0.00 0.00 0.273230E+10 0.273228E+10 6743.71 16-APR-10:52 6743.71 0.00
May 0.00 0.00 0.327680E+10 0.327680E+10 6541.50 11-MAY-07:32 6541.50 0.00
June 0.00 0.00 0.453906E+10 0.453368E+10 6587.29 04-JUN-06:42 6587.29 0.00
July 0.00 0.00 0.484119E+10 0.452262E+10 7208.20 15-JUL-06:42 4920.04 0.00
August 0.00 0.00 0.461138E+10 0.431451E+10 7155.87 04-AUG-07:32 4877.76 0.00
September 0.00 0.00 0.404975E+10 0.376602E+10 7422.76 03-SEP-10:42 4247.79 0.00
October 0.00 0.00 0.224284E+10 0.219472E+10 7125.43 03-OCT-07:22 5144.39 0.00
November 0.00 0.00 0.876182E+09 0.861718E+09 7205.71 13-NOV-17:01 4646.61 0.00
December 0.00 0.00 0.449275E+09 0.449275E+09 6568.88 13-DEC-17:01 6568.88 0.00
                 
Annual Sum or Average 0.00 0.00 0.294126E+11 0.284394E+11       0.00
Minimum of Months 0.00 0.00 0.279830E+09 0.276641E+09 6541.50   4247.79 0.00
Maximum of Months 0.00 0.00 0.484119E+10 0.453368E+10 7422.76   6757.94 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TNE HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.101827E+09 0.101648E+09 6398.28 26-JAN-14:42 6398.28 0.00
February 0.00 0.00 2723888.13 2516460.60 3850.46 18-FEB-19:12 3274.05 0.00
March 0.00 0.00 0.325511E+09 0.325309E+09 6606.28 18-MAR-11:32 6606.28 0.00
April 0.00 0.00 0.235929E+10 0.235928E+10 6691.24 16-APR-12:02 6691.24 0.00
May 0.00 0.00 0.344466E+10 0.344466E+10 6579.90 13-MAY-10:12 6579.90 0.00
June 0.00 0.00 0.494840E+10 0.494258E+10 6566.67 04-JUN-06:42 6566.67 0.00
July 0.00 0.00 0.510202E+10 0.476225E+10 7192.82 15-JUL-06:42 4893.74 0.00
August 0.00 0.00 0.463712E+10 0.431528E+10 7173.72 04-AUG-09:12 4947.78 0.00
September 0.00 0.00 0.372686E+10 0.343207E+10 7370.83 03-SEP-11:22 4343.88 0.00
October 0.00 0.00 0.144129E+10 0.139254E+10 7096.92 03-OCT-08:62 5088.37 0.00
November 0.00 0.00 0.200416E+09 0.194351E+09 7155.92 11-NOV-22:52 4609.63 0.00
December 0.00 0.00 16966476.04 16966476.04 2962.43 24-DEC-14:43 2962.43 0.00
                 
Annual Sum or Average 0.00 0.00 0.263071E+11 0.252895E+11       0.00
Minimum of Months 0.00 0.00 2723888.13 2516460.60 2962.43   2962.43 0.00
Maximum of Months 0.00 0.00 0.510202E+10 0.494258E+10 7370.83   6691.24 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TN1 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 84581229.84 83784647.71 6279.61 08-JAN-20:12 4597.35 0.00
February 0.00 0.00 5729806.54 5333168.75 4600.76 18-FEB-19:12 3937.68 0.00
March 0.00 0.00 0.286273E+09 0.285960E+09 5923.97 11-MAR-18:52 5829.34 0.00
April 0.00 0.00 0.184595E+10 0.184593E+10 5892.04 16-APR-12:22 5892.04 0.00
May 0.00 0.00 0.269889E+10 0.269889E+10 5843.77 11-MAY-08:62 5843.77 0.00
June 0.00 0.00 0.386126E+10 0.385604E+10 5895.34 04-JUN-06:42 5895.34 0.00
July 0.00 0.00 0.408161E+10 0.377703E+10 6455.44 15-JUL-06:42 4408.41 0.00
August 0.00 0.00 0.371580E+10 0.342549E+10 6439.18 04-AUG-09:12 4456.15 0.00
September 0.00 0.00 0.307482E+10 0.280850E+10 6617.30 03-SEP-11:22 3910.62 0.00
October 0.00 0.00 0.118706E+10 0.114254E+10 6371.01 03-OCT-08:62 4528.22 0.00
November 0.00 0.00 0.196486E+09 0.184551E+09 6448.54 12-NOV-22:52 4000.01 0.00
December 0.00 0.00 11810854.07 11810854.07 1555.08 23-DEC-20:12 1555.08 0.00
                 
Annual Sum or Average 0.00 0.00 0.210503E+11 0.201259E+11       0.00
Minimum of Months 0.00 0.00 5729806.54 5333168.75 1555.08   1555.08 0.00
Maximum of Months 0.00 0.00 0.408161E+10 0.385604E+10 6617.30   5895.34 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TN2 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 85485312.43 84706740.01 6253.62 08-JAN-20:12 4575.29 0.00
February 0.00 0.00 5924786.96 5489873.18 4947.63 18-FEB-19:12 4240.07 0.00
March 0.00 0.00 0.288492E+09 0.288157E+09 5898.67 11-MAR-18:52 5798.69 0.00
April 0.00 0.00 0.185562E+10 0.185560E+10 5869.42 16-APR-12:22 5869.42 0.00
May 0.00 0.00 0.270792E+10 0.270792E+10 5822.02 11-MAY-08:62 5822.02 0.00
June 0.00 0.00 0.386588E+10 0.386066E+10 5872.02 04-JUN-06:42 5872.02 0.00
July 0.00 0.00 0.408869E+10 0.378385E+10 6429.96 15-JUL-06:42 4390.39 0.00
August 0.00 0.00 0.372305E+10 0.343236E+10 6413.17 04-AUG-09:12 4438.61 0.00
September 0.00 0.00 0.308015E+10 0.281347E+10 6590.61 03-SEP-11:22 3895.21 0.00
October 0.00 0.00 0.119317E+10 0.114858E+10 6345.90 03-OCT-08:62 4513.33 0.00
November 0.00 0.00 0.193571E+09 0.182207E+09 6417.17 11-NOV-22:52 4223.00 0.00
December 0.00 0.00 12088035.11 12088035.11 1681.99 24-DEC-14:43 1681.99 0.00
                 
Annual Sum or Average 0.00 0.00 0.211000E+11 0.201751E+11       0.00
Minimum of Months 0.00 0.00 5924786.96 5489873.18 1681.99   1681.99 0.00
Maximum of Months 0.00 0.00 0.408869E+10 0.386066E+10 6590.61   5872.02 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TS1 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.986036E+09 0.983327E+09 6334.76 08-JAN-20:12 4775.58 0.00
February 0.00 0.00 0.325333E+09 0.321288E+09 6177.21 18-FEB-19:12 5337.75 0.00
March 0.00 0.00 0.589538E+09 0.588083E+09 6012.54 11-MAR-18:52 6008.35 0.00
April 0.00 0.00 0.225966E+10 0.225962E+10 5972.33 16-APR-13:22 5972.33 0.00
May 0.00 0.00 0.259825E+10 0.259825E+10 5856.99 11-MAY-07:32 5856.99 0.00
June 0.00 0.00 0.352402E+10 0.351909E+10 5915.97 04-JUN-06:42 5915.97 0.00
July 0.00 0.00 0.388507E+10 0.359952E+10 6481.78 15-JUL-06:42 4436.36 0.00
August 0.00 0.00 0.376159E+10 0.349204E+10 6443.14 05-AUG-09:12 4512.61 0.00
September 0.00 0.00 0.344988E+10 0.319053E+10 6675.29 03-SEP-10:42 3836.73 0.00
October 0.00 0.00 0.203094E+10 0.198533E+10 6404.49 03-OCT-07:22 4599.02 0.00
November 0.00 0.00 0.959864E+09 0.937105E+09 6498.51 13-NOV-17:01 4251.82 0.00
December 0.00 0.00 0.533834E+09 0.533834E+09 5919.99 13-DEC-17:01 5919.99 0.00
                 
Annual Sum or Average 0.00 0.00 0.249040E+11 0.240080E+11       0.00
Minimum of Months 0.00 0.00 0.325333E+09 0.321288E+09 5856.99   3836.73 0.00
Maximum of Months 0.00 0.00 0.388507E+10 0.359952E+10 6675.29   6008.35 0.00



Table of Contents

Report: CoilReportMonthly

For: SPLIT TS2 HP COOLING COIL

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.991272E+09 0.988552E+09 6309.43 08-JAN-20:12 4755.36 0.00
February 0.00 0.00 0.333034E+09 0.328833E+09 6154.41 18-FEB-19:12 5322.93 0.00
March 0.00 0.00 0.595368E+09 0.593874E+09 6004.82 04-MAR-13:52 6004.82 0.00
April 0.00 0.00 0.227013E+10 0.227008E+10 5954.46 16-APR-13:22 5954.46 0.00
May 0.00 0.00 0.260906E+10 0.260906E+10 5838.54 11-MAY-07:32 5838.54 0.00
June 0.00 0.00 0.353123E+10 0.352629E+10 5892.76 04-JUN-06:42 5892.76 0.00
July 0.00 0.00 0.389423E+10 0.360834E+10 6456.29 15-JUL-06:42 4419.09 0.00
August 0.00 0.00 0.377100E+10 0.350105E+10 6416.36 05-AUG-09:12 4494.82 0.00
September 0.00 0.00 0.345626E+10 0.319656E+10 6648.54 03-SEP-10:42 3821.63 0.00
October 0.00 0.00 0.203996E+10 0.199425E+10 6379.09 03-OCT-07:22 4582.04 0.00
November 0.00 0.00 0.962513E+09 0.940133E+09 6470.82 13-NOV-17:01 4223.21 0.00
December 0.00 0.00 0.538325E+09 0.538325E+09 5896.37 13-DEC-17:01 5896.37 0.00
                 
Annual Sum or Average 0.00 0.00 0.249924E+11 0.240954E+11       0.00
Minimum of Months 0.00 0.00 0.333034E+09 0.328833E+09 5838.54   3821.63 0.00
Maximum of Months 0.00 0.00 0.389423E+10 0.360834E+10 6648.54   6004.82 0.00



Table of Contents

Report: PlantLoopDemandReportMonthly

For: SWHSYS1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 0.00 0.00 01-JAN-00:10 9175.56 17548.02 23-JAN-07:50
February 0.00 0.00 01-FEB-00:10 9083.94 17515.12 01-FEB-07:40
March 0.00 0.00 01-MAR-00:10 8655.62 17008.24 01-MAR-07:50
April 0.00 0.00 01-APR-00:10 7982.63 15871.57 01-APR-06:50
May 0.00 0.00 01-MAY-00:10 7252.29 14486.77 01-MAY-06:50
June 0.00 0.00 01-JUN-00:10 6660.36 13151.57 01-JUN-06:40
July 0.00 0.00 01-JUL-00:10 6368.31 12292.21 01-JUL-06:50
August 0.00 0.00 01-AUG-00:10 6457.14 12618.20 31-AUG-06:50
September 0.00 0.00 01-SEP-00:10 6900.27 13712.09 30-SEP-06:50
October 0.00 0.00 01-OCT-00:10 7578.32 15137.80 31-OCT-06:40
November 0.00 0.00 01-NOV-00:10 8307.55 16438.20 30-NOV-07:40
December 0.00 0.00 01-DEC-00:10 8891.54 17332.53 31-DEC-07:40
             
Annual Sum or Average 0.00     7768.81    
Minimum of Months 0.00 0.00   6368.31 12292.21  
Maximum of Months 0.00 0.00   9175.56 17548.02  



Table of Contents

Report: FanReportMonthly

For: SPLIT GSW SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 82346605.43 0.76 383.01 02-JAN-13:12 1.01
February 14645891.62 0.23 383.01 01-FEB-17:01 1.01
March 24407174.58 0.25 383.01 01-MAR-17:02 1.01
April 0.163267E+09 0.85 383.01 02-APR-09:32 1.01
May 0.189836E+09 0.87 383.01 01-MAY-16:01 1.02
June 0.279509E+09 1.01 383.01 01-JUN-06:52 1.01
July 0.320861E+09 1.05 383.01 01-JUL-07:52 1.01
August 0.322334E+09 1.02 383.01 01-AUG-16:01 1.00
September 0.314776E+09 0.98 383.01 01-SEP-06:52 1.00
October 0.213976E+09 0.86 383.01 01-OCT-07:32 1.00
November 0.128599E+09 0.83 383.01 01-NOV-16:01 1.00
December 74819462.82 0.67 383.01 01-DEC-17:01 1.01
           
Annual Sum or Average 0.212938E+10 0.79      
Minimum of Months 14645891.62 0.23 383.01   1.00
Maximum of Months 0.322334E+09 1.05 383.01   1.02



Table of Contents

Report: FanReportMonthly

For: G SW APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: G SW APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.77
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT GNW SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 11759494.28 0.16 376.61 18-JAN-14:42 1.01
February 279331.51 0.01 238.14 01-FEB-17:12 1.08
March 11273745.61 0.14 376.61 17-MAR-20:02 1.01
April 0.136637E+09 0.87 376.61 03-APR-09:42 1.02
May 0.203797E+09 0.98 376.61 01-MAY-10:42 1.01
June 0.313536E+09 1.06 376.61 01-JUN-07:22 1.01
July 0.343014E+09 1.09 376.61 01-JUL-07:52 1.01
August 0.330393E+09 1.05 376.61 03-AUG-19:12 1.00
September 0.297169E+09 0.99 376.61 01-SEP-07:02 1.00
October 0.153699E+09 0.78 376.61 01-OCT-07:42 1.00
November 51918849.79 0.54 376.61 01-NOV-11:12 1.00
December 7314810.24 0.14 376.61 01-DEC-19:12 1.01
           
Annual Sum or Average 0.186079E+10 0.65      
Minimum of Months 279331.51 0.01 238.14   1.00
Maximum of Months 0.343014E+09 1.09 376.61   1.08



Table of Contents

Report: FanReportMonthly

For: G NW APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.77 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: G NW APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT OFFICE SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.118266E+10 1.02 458.18 01-JAN-00:10 1.01
February 0.105523E+10 1.02 458.18 01-FEB-00:10 1.02
March 0.116347E+10 1.02 458.18 01-MAR-00:10 1.01
April 0.115154E+10 1.02 458.18 01-APR-00:10 1.01
May 0.119022E+10 1.02 458.18 01-MAY-00:10 1.02
June 0.116147E+10 1.01 458.18 01-JUN-00:10 1.02
July 0.120577E+10 1.01 458.18 01-JUL-00:10 1.01
August 0.120382E+10 1.01 458.18 01-AUG-00:10 1.00
September 0.116709E+10 1.01 458.18 01-SEP-00:10 1.00
October 0.119647E+10 1.01 458.18 01-OCT-00:10 1.01
November 0.114893E+10 1.02 458.18 01-NOV-00:10 1.01
December 0.117908E+10 1.02 458.18 01-DEC-00:10 1.01
           
Annual Sum or Average 0.140057E+11 1.01      
Minimum of Months 0.105523E+10 1.01 458.18   1.00
Maximum of Months 0.120577E+10 1.02 458.18   1.02



Table of Contents

Report: FanReportMonthly

For: SPLIT GNE SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 10419670.60 0.16 349.91 17-JAN-13:42 1.02
February 244080.63 0.01 105.00 01-FEB-17:12 1.14
March 11109126.77 0.14 349.91 16-MAR-11:12 1.01
April 0.136843E+09 0.88 349.91 02-APR-09:32 1.01
May 0.206208E+09 1.00 349.91 01-MAY-10:42 1.01
June 0.315876E+09 1.06 349.91 01-JUN-07:22 1.01
July 0.351479E+09 1.08 349.91 01-JUL-07:52 1.01
August 0.338028E+09 1.04 349.91 03-AUG-19:12 1.00
September 0.300390E+09 0.98 349.91 01-SEP-07:02 1.00
October 0.155931E+09 0.78 349.91 01-OCT-07:42 1.00
November 49050469.27 0.55 349.91 01-NOV-11:12 1.00
December 7186179.45 0.15 349.91 01-DEC-19:12 1.01
           
Annual Sum or Average 0.188276E+10 0.66      
Minimum of Months 244080.63 0.01 105.00   1.00
Maximum of Months 0.351479E+09 1.08 349.91   1.14



Table of Contents

Report: FanReportMonthly

For: G NE APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.77 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: G NE APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT GN1 SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 13614494.67 0.31 300.03 08-JAN-20:12 1.00
February 737575.93 0.04 192.80 01-FEB-17:12 1.08
March 13650771.47 0.24 300.03 16-MAR-11:12 1.01
April 0.115719E+09 0.88 300.03 03-APR-09:42 1.02
May 0.172355E+09 0.98 300.03 01-MAY-10:42 1.01
June 0.254447E+09 1.06 300.03 01-JUN-07:22 1.01
July 0.284508E+09 1.08 300.03 01-JUL-07:52 1.01
August 0.272421E+09 1.04 300.03 03-AUG-19:12 1.00
September 0.246546E+09 0.99 300.03 01-SEP-07:02 1.00
October 0.134204E+09 0.78 300.03 01-OCT-07:42 1.00
November 53776868.44 0.64 300.03 01-NOV-11:12 1.00
December 12175652.53 0.30 300.03 01-DEC-19:12 1.01
           
Annual Sum or Average 0.157416E+10 0.70      
Minimum of Months 737575.93 0.04 192.80   1.00
Maximum of Months 0.284508E+09 1.08 300.03   1.08



Table of Contents

Report: FanReportMonthly

For: G N1 APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: G N1 APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT GN2 SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 13647324.26 0.31 299.56 08-JAN-20:12 1.00
February 768193.44 0.04 192.63 01-FEB-17:12 1.08
March 13809173.47 0.24 299.56 16-MAR-11:12 1.01
April 0.116220E+09 0.88 299.56 03-APR-09:42 1.02
May 0.172828E+09 0.98 299.56 01-MAY-10:42 1.01
June 0.254686E+09 1.06 299.56 01-JUN-07:22 1.01
July 0.284929E+09 1.08 299.56 01-JUL-07:52 1.01
August 0.272842E+09 1.04 299.56 03-AUG-19:12 1.00
September 0.246805E+09 0.99 299.56 01-SEP-07:02 1.00
October 0.134623E+09 0.78 299.56 01-OCT-07:42 1.00
November 53527216.51 0.64 299.56 01-NOV-11:12 1.00
December 12232348.64 0.30 299.56 01-DEC-19:12 1.01
           
Annual Sum or Average 0.157692E+10 0.70      
Minimum of Months 768193.44 0.04 192.63   1.00
Maximum of Months 0.284929E+09 1.08 299.56   1.08



Table of Contents

Report: FanReportMonthly

For: G N2 APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: G N2 APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT GS1 SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.105362E+09 0.82 305.97 02-JAN-13:12 1.01
February 32051096.61 0.56 305.97 01-FEB-17:01 1.01
March 36897953.48 0.43 305.97 01-MAR-17:02 1.01
April 0.146546E+09 0.86 305.97 01-APR-09:42 1.01
May 0.162551E+09 0.85 305.97 01-MAY-16:01 1.02
June 0.225249E+09 0.98 305.97 01-JUN-06:52 1.01
July 0.267332E+09 1.03 305.97 01-JUL-07:52 1.01
August 0.269894E+09 1.01 305.97 01-AUG-16:01 1.00
September 0.268856E+09 0.97 305.97 01-SEP-06:52 1.00
October 0.197953E+09 0.87 305.97 01-OCT-07:32 1.00
November 0.136162E+09 0.84 305.97 01-NOV-16:01 1.00
December 0.100291E+09 0.82 305.97 01-DEC-17:01 1.01
           
Annual Sum or Average 0.194914E+10 0.84      
Minimum of Months 32051096.61 0.43 305.97   1.00
Maximum of Months 0.269894E+09 1.03 305.97   1.02



Table of Contents

Report: FanReportMonthly

For: G S1 APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: G S1 APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.77
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT GS2 SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.104949E+09 0.81 312.45 02-JAN-13:12 1.01
February 31184925.02 0.55 312.45 01-FEB-17:01 1.01
March 37640140.70 0.43 312.45 01-MAR-17:02 1.01
April 0.155892E+09 0.87 312.45 01-APR-09:42 1.01
May 0.175594E+09 0.87 312.45 01-MAY-16:01 1.02
June 0.242900E+09 1.00 312.45 01-JUN-06:52 1.01
July 0.288514E+09 1.04 312.45 01-JUL-07:52 1.01
August 0.288289E+09 1.01 312.45 01-AUG-16:01 1.00
September 0.286443E+09 0.97 312.45 01-SEP-06:52 1.00
October 0.209069E+09 0.87 312.45 01-OCT-07:32 1.00
November 0.138142E+09 0.84 312.45 01-NOV-16:01 1.00
December 99213912.27 0.82 312.45 01-DEC-17:01 1.01
           
Annual Sum or Average 0.205783E+10 0.84      
Minimum of Months 31184925.02 0.43 312.45   1.00
Maximum of Months 0.288514E+09 1.04 312.45   1.02



Table of Contents

Report: FanReportMonthly

For: G S2 APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: G S2 APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.77
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT MSW SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.244177E+09 0.82 872.00 02-JAN-13:12 1.01
February 0.113512E+09 0.68 872.00 01-FEB-17:01 1.01
March 0.157184E+09 0.60 872.00 01-MAR-17:02 1.01
April 0.450111E+09 0.90 872.00 01-APR-09:42 1.01
May 0.508384E+09 0.91 872.00 01-MAY-16:01 1.02
June 0.657591E+09 1.00 872.00 01-JUN-06:52 1.01
July 0.660368E+09 1.03 872.00 01-JUL-07:52 1.01
August 0.636438E+09 1.00 872.00 01-AUG-16:01 1.00
September 0.580306E+09 0.96 872.00 01-SEP-06:52 1.00
October 0.393463E+09 0.85 872.00 01-OCT-07:32 1.00
November 0.237275E+09 0.81 872.00 01-NOV-16:01 1.00
December 0.156421E+09 0.62 872.00 01-DEC-17:01 1.01
           
Annual Sum or Average 0.479523E+10 0.85      
Minimum of Months 0.113512E+09 0.60 872.00   1.00
Maximum of Months 0.660368E+09 1.03 872.00   1.02



Table of Contents

Report: FanReportMonthly

For: M SW APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.117990E+09 0.77 44.05 01-JAN-00:10 0.77
February 0.106572E+09 0.76 44.05 01-FEB-00:10 0.77
March 0.117990E+09 0.76 44.05 01-MAR-00:10 0.76
April 0.114184E+09 0.77 44.05 01-APR-00:10 0.77
May 0.117990E+09 0.77 44.05 01-MAY-00:10 0.77
June 0.114184E+09 0.77 44.05 01-JUN-00:10 0.77
July 0.117990E+09 0.76 44.05 01-JUL-00:10 0.76
August 0.117990E+09 0.76 44.05 01-AUG-00:10 0.76
September 0.114184E+09 0.76 44.05 01-SEP-00:10 0.76
October 0.117990E+09 0.76 44.05 01-OCT-00:10 0.76
November 0.114184E+09 0.76 44.05 01-NOV-00:10 0.76
December 0.117990E+09 0.77 44.05 01-DEC-00:10 0.77
           
Annual Sum or Average 0.138924E+10 0.76      
Minimum of Months 0.106572E+09 0.76 44.05   0.76
Maximum of Months 0.117990E+09 0.77 44.05   0.77



Table of Contents

Report: FanReportMonthly

For: M SW APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.117990E+09 0.77 44.05 01-JAN-00:10 0.77
February 0.106572E+09 0.76 44.05 01-FEB-00:10 0.77
March 0.117990E+09 0.76 44.05 01-MAR-00:10 0.76
April 0.114184E+09 0.77 44.05 01-APR-00:10 0.77
May 0.117990E+09 0.77 44.05 01-MAY-00:10 0.77
June 0.114184E+09 0.77 44.05 01-JUN-00:10 0.77
July 0.117990E+09 0.76 44.05 01-JUL-00:10 0.76
August 0.117990E+09 0.76 44.05 01-AUG-00:10 0.76
September 0.114184E+09 0.76 44.05 01-SEP-00:10 0.76
October 0.117990E+09 0.76 44.05 01-OCT-00:10 0.76
November 0.114184E+09 0.76 44.05 01-NOV-00:10 0.77
December 0.117990E+09 0.77 44.05 01-DEC-00:10 0.77
           
Annual Sum or Average 0.138924E+10 0.76      
Minimum of Months 0.106572E+09 0.76 44.05   0.76
Maximum of Months 0.117990E+09 0.77 44.05   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT MNW SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 53505686.84 0.32 859.96 07-JAN-22:52 1.01
February 18832877.93 0.28 859.96 16-FEB-20:12 1.00
March 88342079.18 0.44 859.96 02-MAR-20:42 1.01
April 0.393086E+09 0.91 859.96 01-APR-09:42 1.01
May 0.536450E+09 0.98 859.96 01-MAY-10:42 1.01
June 0.723777E+09 1.06 859.96 01-JUN-07:22 1.01
July 0.700117E+09 1.09 859.96 01-JUL-07:52 1.01
August 0.643710E+09 1.05 859.96 03-AUG-19:12 1.00
September 0.535093E+09 0.99 859.96 01-SEP-07:02 1.00
October 0.260454E+09 0.73 859.96 01-OCT-07:42 1.00
November 79426494.69 0.40 859.96 01-NOV-11:12 1.00
December 14301781.81 0.13 859.96 02-DEC-13:42 1.01
           
Annual Sum or Average 0.404710E+10 0.70      
Minimum of Months 14301781.81 0.13 859.96   1.00
Maximum of Months 0.723777E+09 1.09 859.96   1.01



Table of Contents

Report: FanReportMonthly

For: M NW APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.117990E+09 0.77 44.05 01-JAN-00:10 0.77
February 0.106572E+09 0.76 44.05 01-FEB-00:10 0.77
March 0.117990E+09 0.76 44.05 01-MAR-00:10 0.76
April 0.114184E+09 0.77 44.05 01-APR-00:10 0.77
May 0.117990E+09 0.77 44.05 01-MAY-00:10 0.77
June 0.114184E+09 0.77 44.05 01-JUN-00:10 0.77
July 0.117990E+09 0.76 44.05 01-JUL-00:10 0.76
August 0.117990E+09 0.76 44.05 01-AUG-00:10 0.76
September 0.114184E+09 0.76 44.05 01-SEP-00:10 0.76
October 0.117990E+09 0.76 44.05 01-OCT-00:10 0.76
November 0.114184E+09 0.76 44.05 01-NOV-00:10 0.76
December 0.117990E+09 0.77 44.05 01-DEC-00:10 0.77
           
Annual Sum or Average 0.138924E+10 0.76      
Minimum of Months 0.106572E+09 0.76 44.05   0.76
Maximum of Months 0.117990E+09 0.77 44.05   0.77



Table of Contents

Report: FanReportMonthly

For: M NW APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.117990E+09 0.77 44.05 01-JAN-00:10 0.77
February 0.106572E+09 0.76 44.05 01-FEB-00:10 0.77
March 0.117990E+09 0.76 44.05 01-MAR-00:10 0.76
April 0.114184E+09 0.77 44.05 01-APR-00:10 0.77
May 0.117990E+09 0.77 44.05 01-MAY-00:10 0.77
June 0.114184E+09 0.77 44.05 01-JUN-00:10 0.77
July 0.117990E+09 0.76 44.05 01-JUL-00:10 0.76
August 0.117990E+09 0.76 44.05 01-AUG-00:10 0.76
September 0.114184E+09 0.76 44.05 01-SEP-00:10 0.76
October 0.117990E+09 0.76 44.05 01-OCT-00:10 0.76
November 0.114184E+09 0.76 44.05 01-NOV-00:10 0.76
December 0.117990E+09 0.77 44.05 01-DEC-00:10 0.77
           
Annual Sum or Average 0.138924E+10 0.76      
Minimum of Months 0.106572E+09 0.76 44.05   0.76
Maximum of Months 0.117990E+09 0.77 44.05   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT MSE SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.239310E+09 0.83 800.78 02-JAN-13:12 1.01
February 0.120287E+09 0.71 800.78 01-FEB-17:01 1.01
March 0.160907E+09 0.62 800.78 01-MAR-17:02 1.01
April 0.449418E+09 0.94 800.78 01-APR-09:42 1.01
May 0.509513E+09 0.97 800.78 01-MAY-16:01 1.02
June 0.659534E+09 1.04 800.78 01-JUN-06:52 1.01
July 0.676710E+09 1.06 800.78 01-JUL-07:52 1.01
August 0.650770E+09 1.03 800.78 01-AUG-16:01 1.00
September 0.586286E+09 0.99 800.78 01-SEP-06:52 1.00
October 0.397977E+09 0.88 800.78 01-OCT-07:32 1.00
November 0.231192E+09 0.81 800.78 01-NOV-16:01 1.00
December 0.156991E+09 0.63 800.78 01-DEC-17:01 1.01
           
Annual Sum or Average 0.483889E+10 0.88      
Minimum of Months 0.120287E+09 0.62 800.78   1.00
Maximum of Months 0.676710E+09 1.06 800.78   1.02



Table of Contents

Report: FanReportMonthly

For: M SE APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.117990E+09 0.77 44.05 01-JAN-00:10 0.77
February 0.106572E+09 0.76 44.05 01-FEB-00:10 0.77
March 0.117990E+09 0.76 44.05 01-MAR-00:10 0.76
April 0.114184E+09 0.77 44.05 01-APR-00:10 0.77
May 0.117990E+09 0.77 44.05 01-MAY-00:10 0.77
June 0.114184E+09 0.77 44.05 01-JUN-00:10 0.77
July 0.117990E+09 0.76 44.05 01-JUL-00:10 0.76
August 0.117990E+09 0.76 44.05 01-AUG-00:10 0.76
September 0.114184E+09 0.76 44.05 01-SEP-00:10 0.76
October 0.117990E+09 0.76 44.05 01-OCT-00:10 0.76
November 0.114184E+09 0.76 44.05 01-NOV-00:10 0.76
December 0.117990E+09 0.77 44.05 01-DEC-00:10 0.77
           
Annual Sum or Average 0.138924E+10 0.76      
Minimum of Months 0.106572E+09 0.76 44.05   0.76
Maximum of Months 0.117990E+09 0.77 44.05   0.77



Table of Contents

Report: FanReportMonthly

For: M SE APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.117990E+09 0.77 44.05 01-JAN-00:10 0.77
February 0.106572E+09 0.76 44.05 01-FEB-00:10 0.77
March 0.117990E+09 0.76 44.05 01-MAR-00:10 0.76
April 0.114184E+09 0.77 44.05 01-APR-00:10 0.77
May 0.117990E+09 0.77 44.05 01-MAY-00:10 0.77
June 0.114184E+09 0.77 44.05 01-JUN-00:10 0.77
July 0.117990E+09 0.76 44.05 01-JUL-00:10 0.76
August 0.117990E+09 0.76 44.05 01-AUG-00:10 0.76
September 0.114184E+09 0.76 44.05 01-SEP-00:10 0.76
October 0.117990E+09 0.76 44.05 01-OCT-00:10 0.76
November 0.114184E+09 0.76 44.05 01-NOV-00:10 0.77
December 0.117990E+09 0.77 44.05 01-DEC-00:10 0.77
           
Annual Sum or Average 0.138924E+10 0.76      
Minimum of Months 0.106572E+09 0.76 44.05   0.76
Maximum of Months 0.117990E+09 0.77 44.05   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT MNE SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 48894994.15 0.33 788.91 07-JAN-22:52 1.01
February 24036531.29 0.36 788.91 16-FEB-20:12 1.00
March 91677618.95 0.47 788.91 01-MAR-20:42 1.00
April 0.392493E+09 0.91 788.91 01-APR-09:42 1.01
May 0.540435E+09 0.99 788.91 01-MAY-10:42 1.01
June 0.727718E+09 1.06 788.91 01-JUN-07:22 1.01
July 0.718670E+09 1.09 788.91 01-JUL-07:52 1.01
August 0.660477E+09 1.05 788.91 03-AUG-19:12 1.00
September 0.542526E+09 0.99 788.91 01-SEP-07:02 1.00
October 0.265217E+09 0.75 788.91 01-OCT-07:42 1.00
November 72116348.10 0.40 788.91 01-NOV-11:12 1.00
December 13112205.45 0.14 788.91 01-DEC-19:12 1.01
           
Annual Sum or Average 0.409737E+10 0.71      
Minimum of Months 13112205.45 0.14 788.91   1.00
Maximum of Months 0.727718E+09 1.09 788.91   1.01



Table of Contents

Report: FanReportMonthly

For: M NE APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.117990E+09 0.77 44.05 01-JAN-00:10 0.77
February 0.106572E+09 0.76 44.05 01-FEB-00:10 0.77
March 0.117990E+09 0.76 44.05 01-MAR-00:10 0.76
April 0.114184E+09 0.77 44.05 01-APR-00:10 0.77
May 0.117990E+09 0.77 44.05 01-MAY-00:10 0.77
June 0.114184E+09 0.77 44.05 01-JUN-00:10 0.77
July 0.117990E+09 0.76 44.05 01-JUL-00:10 0.76
August 0.117990E+09 0.76 44.05 01-AUG-00:10 0.76
September 0.114184E+09 0.76 44.05 01-SEP-00:10 0.76
October 0.117990E+09 0.76 44.05 01-OCT-00:10 0.76
November 0.114184E+09 0.76 44.05 01-NOV-00:10 0.76
December 0.117990E+09 0.77 44.05 01-DEC-00:10 0.77
           
Annual Sum or Average 0.138924E+10 0.76      
Minimum of Months 0.106572E+09 0.76 44.05   0.76
Maximum of Months 0.117990E+09 0.77 44.05   0.77



Table of Contents

Report: FanReportMonthly

For: M NE APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.117990E+09 0.77 44.05 01-JAN-00:10 0.77
February 0.106572E+09 0.76 44.05 01-FEB-00:10 0.77
March 0.117990E+09 0.76 44.05 01-MAR-00:10 0.76
April 0.114184E+09 0.77 44.05 01-APR-00:10 0.77
May 0.117990E+09 0.77 44.05 01-MAY-00:10 0.77
June 0.114184E+09 0.77 44.05 01-JUN-00:10 0.77
July 0.117990E+09 0.76 44.05 01-JUL-00:10 0.76
August 0.117990E+09 0.76 44.05 01-AUG-00:10 0.76
September 0.114184E+09 0.76 44.05 01-SEP-00:10 0.76
October 0.117990E+09 0.76 44.05 01-OCT-00:10 0.76
November 0.114184E+09 0.76 44.05 01-NOV-00:10 0.77
December 0.117990E+09 0.77 44.05 01-DEC-00:10 0.77
           
Annual Sum or Average 0.138924E+10 0.76      
Minimum of Months 0.106572E+09 0.76 44.05   0.76
Maximum of Months 0.117990E+09 0.77 44.05   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT MN1 SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 69265860.30 0.55 676.41 05-JAN-20:02 1.01
February 47953527.68 0.61 676.41 15-FEB-21:12 1.00
March 0.101128E+09 0.60 676.41 01-MAR-20:42 1.00
April 0.311991E+09 0.91 676.41 01-APR-09:42 1.01
May 0.421486E+09 0.98 676.41 01-MAY-10:42 1.01
June 0.555763E+09 1.06 676.41 01-JUN-07:22 1.01
July 0.562470E+09 1.09 676.41 01-JUL-07:52 1.01
August 0.519119E+09 1.05 676.41 03-AUG-19:12 1.00
September 0.442925E+09 0.99 676.41 01-SEP-07:02 1.00
October 0.232217E+09 0.78 676.41 01-OCT-07:42 1.00
November 90985083.80 0.58 676.41 01-NOV-11:12 1.00
December 27446249.19 0.32 676.41 01-DEC-19:12 1.01
           
Annual Sum or Average 0.338275E+10 0.79      
Minimum of Months 27446249.19 0.32 676.41   1.00
Maximum of Months 0.562470E+09 1.09 676.41   1.01



Table of Contents

Report: FanReportMonthly

For: M N1 APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.117990E+09 0.77 44.05 01-JAN-00:10 0.77
February 0.106572E+09 0.76 44.05 01-FEB-00:10 0.77
March 0.117990E+09 0.76 44.05 01-MAR-00:10 0.76
April 0.114184E+09 0.77 44.05 01-APR-00:10 0.77
May 0.117990E+09 0.77 44.05 01-MAY-00:10 0.77
June 0.114184E+09 0.77 44.05 01-JUN-00:10 0.77
July 0.117990E+09 0.76 44.05 01-JUL-00:10 0.76
August 0.117990E+09 0.76 44.05 01-AUG-00:10 0.76
September 0.114184E+09 0.76 44.05 01-SEP-00:10 0.76
October 0.117990E+09 0.76 44.05 01-OCT-00:10 0.76
November 0.114184E+09 0.76 44.05 01-NOV-00:10 0.76
December 0.117990E+09 0.77 44.05 01-DEC-00:10 0.77
           
Annual Sum or Average 0.138924E+10 0.76      
Minimum of Months 0.106572E+09 0.76 44.05   0.76
Maximum of Months 0.117990E+09 0.77 44.05   0.77



Table of Contents

Report: FanReportMonthly

For: M N1 APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.117990E+09 0.77 44.05 01-JAN-00:10 0.77
February 0.106572E+09 0.76 44.05 01-FEB-00:10 0.77
March 0.117990E+09 0.76 44.05 01-MAR-00:10 0.76
April 0.114184E+09 0.77 44.05 01-APR-00:10 0.77
May 0.117990E+09 0.77 44.05 01-MAY-00:10 0.77
June 0.114184E+09 0.77 44.05 01-JUN-00:10 0.77
July 0.117990E+09 0.76 44.05 01-JUL-00:10 0.76
August 0.117990E+09 0.76 44.05 01-AUG-00:10 0.76
September 0.114184E+09 0.76 44.05 01-SEP-00:10 0.76
October 0.117990E+09 0.76 44.05 01-OCT-00:10 0.76
November 0.114184E+09 0.76 44.05 01-NOV-00:10 0.77
December 0.117990E+09 0.77 44.05 01-DEC-00:10 0.77
           
Annual Sum or Average 0.138924E+10 0.76      
Minimum of Months 0.106572E+09 0.76 44.05   0.76
Maximum of Months 0.117990E+09 0.77 44.05   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT MN2 SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 68989303.60 0.54 675.22 05-JAN-20:02 1.01
February 48749839.70 0.62 675.22 15-FEB-21:12 1.00
March 0.101773E+09 0.60 675.22 01-MAR-20:42 1.00
April 0.313130E+09 0.90 675.22 01-APR-09:42 1.01
May 0.422576E+09 0.98 675.22 01-MAY-10:42 1.01
June 0.556279E+09 1.06 675.22 01-JUN-07:22 1.01
July 0.563308E+09 1.09 675.22 01-JUL-07:52 1.01
August 0.519986E+09 1.05 675.22 03-AUG-19:12 1.00
September 0.443545E+09 0.99 675.22 01-SEP-07:02 1.00
October 0.233036E+09 0.78 675.22 01-OCT-07:42 1.00
November 90657889.11 0.58 675.22 01-NOV-11:12 1.00
December 27627227.83 0.32 675.22 01-DEC-19:12 1.01
           
Annual Sum or Average 0.338966E+10 0.79      
Minimum of Months 27627227.83 0.32 675.22   1.00
Maximum of Months 0.563308E+09 1.09 675.22   1.01



Table of Contents

Report: FanReportMonthly

For: M N2 APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.117990E+09 0.77 44.05 01-JAN-00:10 0.77
February 0.106572E+09 0.76 44.05 01-FEB-00:10 0.77
March 0.117990E+09 0.76 44.05 01-MAR-00:10 0.76
April 0.114184E+09 0.77 44.05 01-APR-00:10 0.77
May 0.117990E+09 0.77 44.05 01-MAY-00:10 0.77
June 0.114184E+09 0.77 44.05 01-JUN-00:10 0.77
July 0.117990E+09 0.76 44.05 01-JUL-00:10 0.76
August 0.117990E+09 0.76 44.05 01-AUG-00:10 0.76
September 0.114184E+09 0.76 44.05 01-SEP-00:10 0.76
October 0.117990E+09 0.76 44.05 01-OCT-00:10 0.76
November 0.114184E+09 0.76 44.05 01-NOV-00:10 0.76
December 0.117990E+09 0.77 44.05 01-DEC-00:10 0.77
           
Annual Sum or Average 0.138924E+10 0.76      
Minimum of Months 0.106572E+09 0.76 44.05   0.76
Maximum of Months 0.117990E+09 0.77 44.05   0.77



Table of Contents

Report: FanReportMonthly

For: M N2 APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.117990E+09 0.77 44.05 01-JAN-00:10 0.77
February 0.106572E+09 0.76 44.05 01-FEB-00:10 0.77
March 0.117990E+09 0.76 44.05 01-MAR-00:10 0.76
April 0.114184E+09 0.77 44.05 01-APR-00:10 0.77
May 0.117990E+09 0.77 44.05 01-MAY-00:10 0.77
June 0.114184E+09 0.77 44.05 01-JUN-00:10 0.77
July 0.117990E+09 0.76 44.05 01-JUL-00:10 0.76
August 0.117990E+09 0.76 44.05 01-AUG-00:10 0.76
September 0.114184E+09 0.76 44.05 01-SEP-00:10 0.76
October 0.117990E+09 0.76 44.05 01-OCT-00:10 0.76
November 0.114184E+09 0.76 44.05 01-NOV-00:10 0.77
December 0.117990E+09 0.77 44.05 01-DEC-00:10 0.77
           
Annual Sum or Average 0.138924E+10 0.76      
Minimum of Months 0.106572E+09 0.76 44.05   0.76
Maximum of Months 0.117990E+09 0.77 44.05   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT MS1 SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.281288E+09 0.85 687.94 02-JAN-13:12 1.01
February 0.163879E+09 0.84 687.94 01-FEB-17:01 1.01
March 0.179254E+09 0.69 687.94 01-MAR-17:02 1.01
April 0.374189E+09 0.88 687.94 01-APR-09:42 1.01
May 0.400770E+09 0.88 687.94 01-MAY-16:01 1.02
June 0.498183E+09 0.97 687.94 01-JUN-06:52 1.01
July 0.530473E+09 0.99 687.94 01-JUL-07:52 1.01
August 0.520112E+09 0.97 687.94 01-AUG-16:01 1.00
September 0.494433E+09 0.95 687.94 01-SEP-06:52 1.00
October 0.371685E+09 0.86 687.94 01-OCT-07:32 1.00
November 0.265888E+09 0.83 687.94 01-NOV-16:01 1.00
December 0.218364E+09 0.82 687.94 01-DEC-17:01 1.01
           
Annual Sum or Average 0.429852E+10 0.88      
Minimum of Months 0.163879E+09 0.69 687.94   1.00
Maximum of Months 0.530473E+09 0.99 687.94   1.02



Table of Contents

Report: FanReportMonthly

For: M S1 APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.117990E+09 0.77 44.05 01-JAN-00:10 0.77
February 0.106572E+09 0.76 44.05 01-FEB-00:10 0.77
March 0.117990E+09 0.76 44.05 01-MAR-00:10 0.76
April 0.114184E+09 0.77 44.05 01-APR-00:10 0.77
May 0.117990E+09 0.77 44.05 01-MAY-00:10 0.77
June 0.114184E+09 0.77 44.05 01-JUN-00:10 0.77
July 0.117990E+09 0.76 44.05 01-JUL-00:10 0.76
August 0.117990E+09 0.76 44.05 01-AUG-00:10 0.76
September 0.114184E+09 0.76 44.05 01-SEP-00:10 0.76
October 0.117990E+09 0.76 44.05 01-OCT-00:10 0.76
November 0.114184E+09 0.76 44.05 01-NOV-00:10 0.76
December 0.117990E+09 0.77 44.05 01-DEC-00:10 0.77
           
Annual Sum or Average 0.138924E+10 0.76      
Minimum of Months 0.106572E+09 0.76 44.05   0.76
Maximum of Months 0.117990E+09 0.77 44.05   0.77



Table of Contents

Report: FanReportMonthly

For: M S1 APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.117990E+09 0.77 44.05 01-JAN-00:10 0.77
February 0.106572E+09 0.76 44.05 01-FEB-00:10 0.77
March 0.117990E+09 0.76 44.05 01-MAR-00:10 0.76
April 0.114184E+09 0.77 44.05 01-APR-00:10 0.77
May 0.117990E+09 0.77 44.05 01-MAY-00:10 0.77
June 0.114184E+09 0.77 44.05 01-JUN-00:10 0.77
July 0.117990E+09 0.76 44.05 01-JUL-00:10 0.76
August 0.117990E+09 0.76 44.05 01-AUG-00:10 0.76
September 0.114184E+09 0.76 44.05 01-SEP-00:10 0.76
October 0.117990E+09 0.76 44.05 01-OCT-00:10 0.76
November 0.114184E+09 0.76 44.05 01-NOV-00:10 0.77
December 0.117990E+09 0.77 44.05 01-DEC-00:10 0.77
           
Annual Sum or Average 0.138924E+10 0.76      
Minimum of Months 0.106572E+09 0.76 44.05   0.76
Maximum of Months 0.117990E+09 0.77 44.05   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT MS2 SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.281593E+09 0.85 686.86 02-JAN-13:12 1.01
February 0.164962E+09 0.84 686.86 01-FEB-17:01 1.01
March 0.180395E+09 0.69 686.86 01-MAR-17:02 1.01
April 0.375666E+09 0.89 686.86 01-APR-09:42 1.01
May 0.402308E+09 0.88 686.86 01-MAY-16:01 1.02
June 0.499269E+09 0.97 686.86 01-JUN-06:52 1.01
July 0.531730E+09 0.99 686.86 01-JUL-07:52 1.01
August 0.521406E+09 0.97 686.86 01-AUG-16:01 1.00
September 0.495259E+09 0.95 686.86 01-SEP-06:52 1.00
October 0.372819E+09 0.86 686.86 01-OCT-07:32 1.00
November 0.265944E+09 0.83 686.86 01-NOV-16:01 1.00
December 0.219110E+09 0.82 686.86 01-DEC-17:01 1.01
           
Annual Sum or Average 0.431046E+10 0.88      
Minimum of Months 0.164962E+09 0.69 686.86   1.00
Maximum of Months 0.531730E+09 0.99 686.86   1.02



Table of Contents

Report: FanReportMonthly

For: M S2 APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.117990E+09 0.77 44.05 01-JAN-00:10 0.77
February 0.106572E+09 0.76 44.05 01-FEB-00:10 0.77
March 0.117990E+09 0.76 44.05 01-MAR-00:10 0.76
April 0.114184E+09 0.77 44.05 01-APR-00:10 0.77
May 0.117990E+09 0.77 44.05 01-MAY-00:10 0.77
June 0.114184E+09 0.77 44.05 01-JUN-00:10 0.77
July 0.117990E+09 0.76 44.05 01-JUL-00:10 0.76
August 0.117990E+09 0.76 44.05 01-AUG-00:10 0.76
September 0.114184E+09 0.76 44.05 01-SEP-00:10 0.76
October 0.117990E+09 0.76 44.05 01-OCT-00:10 0.76
November 0.114184E+09 0.76 44.05 01-NOV-00:10 0.76
December 0.117990E+09 0.77 44.05 01-DEC-00:10 0.77
           
Annual Sum or Average 0.138924E+10 0.76      
Minimum of Months 0.106572E+09 0.76 44.05   0.76
Maximum of Months 0.117990E+09 0.77 44.05   0.77



Table of Contents

Report: FanReportMonthly

For: M S2 APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.117990E+09 0.77 44.05 01-JAN-00:10 0.77
February 0.106572E+09 0.76 44.05 01-FEB-00:10 0.77
March 0.117990E+09 0.76 44.05 01-MAR-00:10 0.76
April 0.114184E+09 0.77 44.05 01-APR-00:10 0.77
May 0.117990E+09 0.77 44.05 01-MAY-00:10 0.77
June 0.114184E+09 0.77 44.05 01-JUN-00:10 0.77
July 0.117990E+09 0.76 44.05 01-JUL-00:10 0.76
August 0.117990E+09 0.76 44.05 01-AUG-00:10 0.76
September 0.114184E+09 0.76 44.05 01-SEP-00:10 0.76
October 0.117990E+09 0.76 44.05 01-OCT-00:10 0.76
November 0.114184E+09 0.76 44.05 01-NOV-00:10 0.77
December 0.117990E+09 0.77 44.05 01-DEC-00:10 0.77
           
Annual Sum or Average 0.138924E+10 0.76      
Minimum of Months 0.106572E+09 0.76 44.05   0.76
Maximum of Months 0.117990E+09 0.77 44.05   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT TSW SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 78795762.30 0.41 503.97 02-JAN-13:12 1.01
February 25625284.20 0.32 503.97 01-FEB-17:01 1.01
March 54122048.97 0.35 503.97 02-MAR-17:01 1.01
April 0.227246E+09 0.81 503.97 01-APR-09:42 1.01
May 0.275164E+09 0.92 503.97 01-MAY-16:01 1.02
June 0.381907E+09 1.03 503.97 01-JUN-06:52 1.01
July 0.377985E+09 1.06 503.97 01-JUL-07:52 1.01
August 0.358354E+09 1.03 503.97 01-AUG-16:01 1.00
September 0.313898E+09 0.98 503.97 01-SEP-06:52 1.00
October 0.177654E+09 0.66 503.97 01-OCT-07:32 1.00
November 74643699.11 0.45 503.97 01-NOV-16:01 1.00
December 57628176.61 0.44 503.97 01-DEC-17:01 1.01
           
Annual Sum or Average 0.240302E+10 0.71      
Minimum of Months 25625284.20 0.32 503.97   1.00
Maximum of Months 0.381907E+09 1.06 503.97   1.02



Table of Contents

Report: FanReportMonthly

For: T SW APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.77 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: T SW APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.77
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT TNW SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 23482048.28 0.29 452.33 18-JAN-14:42 1.03
February 13434315.41 0.30 424.00 22-FEB-20:32 1.03
March 35730289.32 0.29 502.82 09-MAR-18:32 1.01
April 0.199218E+09 0.77 502.82 03-APR-09:42 1.02
May 0.290026E+09 0.95 502.82 01-MAY-10:42 1.01
June 0.418125E+09 1.06 502.82 01-JUN-07:22 1.01
July 0.401353E+09 1.09 502.82 01-JUL-07:52 1.01
August 0.363864E+09 1.05 502.82 03-AUG-19:12 1.00
September 0.292134E+09 0.99 502.82 01-SEP-07:02 1.00
October 0.118077E+09 0.52 502.82 01-OCT-07:42 1.00
November 28541604.53 0.31 502.82 01-NOV-11:12 1.00
December 50805552.92 0.51 190.27 24-DEC-14:43 1.12
           
Annual Sum or Average 0.223479E+10 0.68      
Minimum of Months 13434315.41 0.29 190.27   1.00
Maximum of Months 0.418125E+09 1.09 502.82   1.12



Table of Contents

Report: FanReportMonthly

For: T NW APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.77 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: T NW APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.77
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT TSE SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 73799998.61 0.43 451.55 02-JAN-13:12 1.01
February 25002978.53 0.33 451.55 01-FEB-17:01 1.01
March 52030528.52 0.36 451.55 02-MAR-17:01 1.01
April 0.224017E+09 0.83 451.55 01-APR-09:42 1.01
May 0.273809E+09 0.96 451.55 01-MAY-10:22 1.01
June 0.381949E+09 1.05 451.55 01-JUN-06:52 1.01
July 0.385979E+09 1.07 451.55 01-JUL-07:52 1.01
August 0.365074E+09 1.04 451.55 01-AUG-16:01 1.00
September 0.316243E+09 1.00 451.55 01-SEP-06:52 1.00
October 0.177658E+09 0.68 451.55 01-OCT-07:32 1.00
November 70280431.24 0.46 451.55 01-NOV-16:01 1.00
December 53718502.39 0.44 451.55 01-DEC-17:01 1.01
           
Annual Sum or Average 0.239956E+10 0.72      
Minimum of Months 25002978.53 0.33 451.55   1.00
Maximum of Months 0.385979E+09 1.07 451.55   1.01



Table of Contents

Report: FanReportMonthly

For: T SE APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.77 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: T SE APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.77
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT TNE SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 20464040.52 0.27 450.33 18-JAN-14:42 1.01
February 11713956.07 0.26 273.80 18-FEB-19:12 1.07
March 33705558.81 0.27 450.33 09-MAR-18:32 1.01
April 0.196661E+09 0.77 450.33 01-APR-09:42 1.01
May 0.290361E+09 0.95 450.33 01-MAY-10:22 1.01
June 0.419301E+09 1.06 450.33 01-JUN-07:22 1.01
July 0.410469E+09 1.09 450.33 01-JUL-07:52 1.01
August 0.371980E+09 1.05 450.33 03-AUG-19:12 1.00
September 0.295292E+09 1.00 450.33 01-SEP-07:02 1.00
October 0.117287E+09 0.53 450.33 01-OCT-07:42 1.00
November 24467147.19 0.27 450.33 01-NOV-11:12 1.00
December 47776753.29 0.47 230.75 24-DEC-14:43 1.10
           
Annual Sum or Average 0.223948E+10 0.67      
Minimum of Months 11713956.07 0.26 230.75   1.00
Maximum of Months 0.419301E+09 1.09 450.33   1.10



Table of Contents

Report: FanReportMonthly

For: T NE APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.77 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: T NE APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.77
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT TN1 SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 11612375.87 0.17 404.46 08-JAN-20:12 1.00
February 4289280.11 0.17 317.67 18-FEB-19:12 1.04
March 25828492.07 0.24 404.46 09-MAR-18:32 1.01
April 0.154958E+09 0.81 404.46 02-APR-09:32 1.01
May 0.229300E+09 0.97 404.46 01-MAY-10:42 1.01
June 0.330125E+09 1.06 404.46 01-JUN-07:22 1.01
July 0.329887E+09 1.09 404.46 01-JUL-07:52 1.01
August 0.299259E+09 1.05 404.46 03-AUG-19:12 1.00
September 0.244246E+09 0.99 404.46 01-SEP-07:02 1.00
October 96545175.97 0.55 404.46 01-OCT-07:42 1.00
November 18440130.83 0.24 404.46 01-NOV-11:12 1.00
December 26823576.87 0.36 125.59 23-DEC-20:12 1.14
           
Annual Sum or Average 0.177132E+10 0.65      
Minimum of Months 4289280.11 0.17 125.59   1.00
Maximum of Months 0.330125E+09 1.09 404.46   1.14



Table of Contents

Report: FanReportMonthly

For: T N1 APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.77 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: T N1 APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.77
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT TN2 SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 11773278.75 0.18 402.83 08-JAN-20:12 1.00
February 4288005.90 0.17 338.35 18-FEB-19:12 1.03
March 26001853.14 0.24 402.83 09-MAR-18:32 1.01
April 0.155705E+09 0.81 402.83 02-APR-09:32 1.01
May 0.229980E+09 0.97 402.83 01-MAY-10:42 1.01
June 0.330419E+09 1.06 402.83 01-JUN-07:22 1.01
July 0.330367E+09 1.09 402.83 01-JUL-07:52 1.01
August 0.299757E+09 1.05 402.83 03-AUG-19:12 1.00
September 0.244604E+09 0.99 402.83 01-SEP-07:02 1.00
October 97015157.64 0.55 402.83 01-OCT-07:42 1.00
November 18266827.21 0.24 402.83 01-NOV-11:12 1.00
December 26898695.37 0.36 135.17 24-DEC-14:43 1.13
           
Annual Sum or Average 0.177508E+10 0.65      
Minimum of Months 4288005.90 0.17 135.17   1.00
Maximum of Months 0.330419E+09 1.09 402.83   1.13



Table of Contents

Report: FanReportMonthly

For: T N2 APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.77 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: T N2 APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.77
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT TS1 SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 78360199.94 0.48 406.47 02-JAN-13:12 1.01
February 25848164.93 0.31 406.47 01-FEB-17:01 1.01
March 47144771.88 0.37 406.47 01-MAR-17:02 1.01
April 0.186064E+09 0.86 406.47 01-APR-09:42 1.01
May 0.218213E+09 0.93 406.47 01-MAY-16:01 1.02
June 0.298456E+09 1.03 406.47 01-JUN-06:52 1.01
July 0.310640E+09 1.06 406.47 01-JUL-07:52 1.01
August 0.298465E+09 1.02 406.47 01-AUG-16:01 1.00
September 0.269774E+09 0.98 406.47 01-SEP-06:52 1.00
October 0.161023E+09 0.73 406.47 01-OCT-07:32 1.00
November 75177298.50 0.53 406.47 01-NOV-16:01 1.00
December 48023063.24 0.40 406.47 01-DEC-17:01 1.01
           
Annual Sum or Average 0.201719E+10 0.73      
Minimum of Months 25848164.93 0.31 406.47   1.00
Maximum of Months 0.310640E+09 1.06 406.47   1.02



Table of Contents

Report: FanReportMonthly

For: T S1 APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: T S1 APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.77
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: SPLIT TS2 SUPPLY FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 78760724.81 0.48 404.85 02-JAN-13:12 1.01
February 26454475.09 0.31 404.85 01-FEB-17:01 1.01
March 47589745.75 0.37 404.85 01-MAR-17:02 1.01
April 0.186860E+09 0.87 404.85 01-APR-09:42 1.01
May 0.219060E+09 0.94 404.85 01-MAY-16:01 1.02
June 0.298997E+09 1.03 404.85 01-JUN-06:52 1.01
July 0.311294E+09 1.06 404.85 01-JUL-07:52 1.01
August 0.299136E+09 1.02 404.85 01-AUG-16:01 1.00
September 0.270203E+09 0.98 404.85 01-SEP-06:52 1.00
October 0.161693E+09 0.73 404.85 01-OCT-07:32 1.00
November 75390748.34 0.53 404.85 01-NOV-16:01 1.00
December 48339054.42 0.40 404.85 01-DEC-17:01 1.01
           
Annual Sum or Average 0.202378E+10 0.73      
Minimum of Months 26454475.09 0.31 404.85   1.00
Maximum of Months 0.311294E+09 1.06 404.85   1.02



Table of Contents

Report: FanReportMonthly

For: T S2 APARTMENT ERV SUP FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.76
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: FanReportMonthly

For: T S2 APARTMENT ERV EXH FAN

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 58995248.38 0.77 22.03 01-JAN-00:10 0.77
February 53286030.80 0.76 22.03 01-FEB-00:10 0.77
March 58995248.38 0.76 22.03 01-MAR-00:10 0.76
April 57092175.85 0.77 22.03 01-APR-00:10 0.77
May 58995248.38 0.77 22.03 01-MAY-00:10 0.77
June 57092175.85 0.77 22.03 01-JUN-00:10 0.77
July 58995248.38 0.76 22.03 01-JUL-00:10 0.76
August 58995248.38 0.76 22.03 01-AUG-00:10 0.76
September 57092175.85 0.76 22.03 01-SEP-00:10 0.76
October 58995248.38 0.76 22.03 01-OCT-00:10 0.76
November 57092175.85 0.76 22.03 01-NOV-00:10 0.77
December 58995248.38 0.77 22.03 01-DEC-00:10 0.77
           
Annual Sum or Average 0.694621E+09 0.76      
Minimum of Months 53286030.80 0.76 22.03   0.76
Maximum of Months 58995248.38 0.77 22.03   0.77



Table of Contents

Report: PumpReportMonthly

For: SWHSYS1 PUMP

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PUMP ELECTRICITY ENERGY [J] PUMP FLUID HEAT GAIN ENERGY [J] PUMP ELECTRICITY RATE {Maximum} [W] PUMP ELECTRICITY RATE {TIMESTAMP} PUMP SHAFT POWER {AT MAX/MIN} [W] PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s]
January 34626425.15 10387927.54 12.93 01-JAN-00:10 3.88 3.88 55.82 0.10
February 31275480.78 9382644.23 12.93 01-FEB-00:10 3.88 3.88 55.78 0.10
March 34626425.15 10387927.54 12.93 01-MAR-00:10 3.88 3.88 55.90 0.10
April 33509443.69 10052833.11 12.93 01-APR-00:10 3.88 3.88 58.31 0.10
May 34626425.15 10387927.54 12.93 01-MAY-00:10 3.88 3.88 58.46 0.10
June 33509443.69 10052833.11 12.93 01-JUN-00:10 3.88 3.88 58.59 0.10
July 34626425.15 10387927.54 12.93 01-JUL-00:10 3.88 3.88 58.69 0.10
August 34626425.15 10387927.54 12.93 01-AUG-00:10 3.88 3.88 58.70 0.10
September 33509443.69 10052833.11 12.93 01-SEP-00:10 3.88 3.88 58.65 0.10
October 34626425.15 10387927.54 12.93 01-OCT-00:10 3.88 3.88 58.53 0.10
November 33509443.69 10052833.11 12.93 01-NOV-00:10 3.88 3.88 58.38 0.10
December 34626425.15 10387927.54 12.93 01-DEC-00:10 3.88 3.88 56.03 0.10
                 
Annual Sum or Average 0.407698E+09 0.122309E+09            
Minimum of Months 31275480.78 9382644.23 12.93   3.88 3.88 55.78 0.10
Maximum of Months 34626425.15 10387927.54 12.93   3.88 3.88 58.70 0.10



Table of Contents

Report: CondLoopDemandReportMonthly

For: SWHSYS1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 0.00 0.00 01-JAN-00:10 55.82 59.95 9175.56 17548.02 23-JAN-07:50
February 0.00 0.00 01-FEB-00:10 55.78 59.95 9083.94 17515.12 01-FEB-07:40
March 0.00 0.00 01-MAR-00:10 55.90 59.95 8655.62 17008.24 01-MAR-07:50
April 0.00 0.00 01-APR-00:10 58.31 59.95 7982.63 15871.57 01-APR-06:50
May 0.00 0.00 01-MAY-00:10 58.46 59.96 7252.29 14486.77 01-MAY-06:50
June 0.00 0.00 01-JUN-00:10 58.59 59.94 6660.36 13151.57 01-JUN-06:40
July 0.00 0.00 01-JUL-00:10 58.69 59.95 6368.31 12292.21 01-JUL-06:50
August 0.00 0.00 01-AUG-00:10 58.70 59.94 6457.14 12618.20 31-AUG-06:50
September 0.00 0.00 01-SEP-00:10 58.65 59.96 6900.27 13712.09 30-SEP-06:50
October 0.00 0.00 01-OCT-00:10 58.53 59.95 7578.32 15137.80 31-OCT-06:40
November 0.00 0.00 01-NOV-00:10 58.38 59.95 8307.55 16438.20 30-NOV-07:40
December 0.00 0.00 01-DEC-00:10 56.03 59.95 8891.54 17332.53 31-DEC-07:40
                 
Annual Sum or Average 0.00         7768.81    
Minimum of Months 0.00 0.00   55.78 59.94 6368.31 12292.21  
Maximum of Months 0.00 0.00   58.70 59.96 9175.56 17548.02  



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: G SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: G NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: OFFICE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: G NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: G N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: G N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: G S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: G S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: M SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: M NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: M SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: M NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: M N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: M N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: M S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: M S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: T SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: T NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: T SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: T NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: T N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: T N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: T S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: T S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: T CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: G CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: M CORRIDOR

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT GSW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.339667E+09 0.00 0.00
February 0.00 0.00 0.00 60404314.44 0.00 0.00
March 0.00 0.00 0.00 0.101572E+09 0.00 0.00
April 0.00 0.00 0.00 0.683451E+09 0.00 0.00
May 0.00 0.00 0.00 0.798869E+09 0.00 0.00
June 0.00 0.00 0.00 0.120828E+10 0.00 0.00
July 0.00 0.00 0.00 0.140734E+10 0.00 0.00
August 0.00 0.00 0.00 0.141306E+10 0.00 0.00
September 0.00 0.00 0.00 0.136798E+10 0.00 0.00
October 0.00 0.00 0.00 0.901980E+09 0.00 0.00
November 0.00 0.00 0.00 0.534961E+09 0.00 0.00
December 0.00 0.00 0.00 0.310673E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.912824E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 60404314.44 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.141306E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT GNW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 51374141.14 0.00 0.00
February 0.00 0.00 0.00 1145999.35 0.00 0.00
March 0.00 0.00 0.00 47178332.92 0.00 0.00
April 0.00 0.00 0.00 0.573435E+09 0.00 0.00
May 0.00 0.00 0.00 0.859517E+09 0.00 0.00
June 0.00 0.00 0.00 0.135561E+10 0.00 0.00
July 0.00 0.00 0.00 0.150621E+10 0.00 0.00
August 0.00 0.00 0.00 0.145197E+10 0.00 0.00
September 0.00 0.00 0.00 0.129343E+10 0.00 0.00
October 0.00 0.00 0.00 0.651818E+09 0.00 0.00
November 0.00 0.00 0.00 0.216093E+09 0.00 0.00
December 0.00 0.00 0.00 30044699.81 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.803782E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 1145999.35 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.150621E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT OFFICE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.146593E+10 0.00 0.00
February 0.00 0.00 0.00 0.117316E+10 0.00 0.00
March 0.00 0.00 0.00 0.134075E+10 0.00 0.00
April 0.00 0.00 0.00 0.162654E+10 0.00 0.00
May 0.00 0.00 0.00 0.180231E+10 0.00 0.00
June 0.00 0.00 0.00 0.207726E+10 0.00 0.00
July 0.00 0.00 0.00 0.216603E+10 0.00 0.00
August 0.00 0.00 0.00 0.226298E+10 0.00 0.00
September 0.00 0.00 0.00 0.206844E+10 0.00 0.00
October 0.00 0.00 0.00 0.182545E+10 0.00 0.00
November 0.00 0.00 0.00 0.154249E+10 0.00 0.00
December 0.00 0.00 0.00 0.141371E+10 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.207650E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.117316E+10 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.226298E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT GNE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 45916697.41 0.00 0.00
February 0.00 0.00 0.00 1003400.40 0.00 0.00
March 0.00 0.00 0.00 46491578.11 0.00 0.00
April 0.00 0.00 0.00 0.574283E+09 0.00 0.00
May 0.00 0.00 0.00 0.869671E+09 0.00 0.00
June 0.00 0.00 0.00 0.136573E+10 0.00 0.00
July 0.00 0.00 0.00 0.154306E+10 0.00 0.00
August 0.00 0.00 0.00 0.148503E+10 0.00 0.00
September 0.00 0.00 0.00 0.130715E+10 0.00 0.00
October 0.00 0.00 0.00 0.661301E+09 0.00 0.00
November 0.00 0.00 0.00 0.204180E+09 0.00 0.00
December 0.00 0.00 0.00 29512756.77 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.813333E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 1003400.40 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.154306E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT GN1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 56952807.43 0.00 0.00
February 0.00 0.00 0.00 3030329.74 0.00 0.00
March 0.00 0.00 0.00 56974809.28 0.00 0.00
April 0.00 0.00 0.00 0.484928E+09 0.00 0.00
May 0.00 0.00 0.00 0.726017E+09 0.00 0.00
June 0.00 0.00 0.00 0.109939E+10 0.00 0.00
July 0.00 0.00 0.00 0.124922E+10 0.00 0.00
August 0.00 0.00 0.00 0.119676E+10 0.00 0.00
September 0.00 0.00 0.00 0.107274E+10 0.00 0.00
October 0.00 0.00 0.00 0.568241E+09 0.00 0.00
November 0.00 0.00 0.00 0.223875E+09 0.00 0.00
December 0.00 0.00 0.00 50062792.72 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.678820E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 3030329.74 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.124922E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT GN2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 57132930.67 0.00 0.00
February 0.00 0.00 0.00 3157351.21 0.00 0.00
March 0.00 0.00 0.00 57634452.50 0.00 0.00
April 0.00 0.00 0.00 0.487031E+09 0.00 0.00
May 0.00 0.00 0.00 0.728017E+09 0.00 0.00
June 0.00 0.00 0.00 0.110044E+10 0.00 0.00
July 0.00 0.00 0.00 0.125108E+10 0.00 0.00
August 0.00 0.00 0.00 0.119861E+10 0.00 0.00
September 0.00 0.00 0.00 0.107387E+10 0.00 0.00
October 0.00 0.00 0.00 0.569994E+09 0.00 0.00
November 0.00 0.00 0.00 0.222842E+09 0.00 0.00
December 0.00 0.00 0.00 50295393.38 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.680010E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 3157351.21 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.125108E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT GS1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.434653E+09 0.00 0.00
February 0.00 0.00 0.00 0.132660E+09 0.00 0.00
March 0.00 0.00 0.00 0.153286E+09 0.00 0.00
April 0.00 0.00 0.00 0.612213E+09 0.00 0.00
May 0.00 0.00 0.00 0.682448E+09 0.00 0.00
June 0.00 0.00 0.00 0.971835E+09 0.00 0.00
July 0.00 0.00 0.00 0.117122E+10 0.00 0.00
August 0.00 0.00 0.00 0.118115E+10 0.00 0.00
September 0.00 0.00 0.00 0.116707E+10 0.00 0.00
October 0.00 0.00 0.00 0.832796E+09 0.00 0.00
November 0.00 0.00 0.00 0.566067E+09 0.00 0.00
December 0.00 0.00 0.00 0.423783E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.832919E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.132660E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.118115E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT GS2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.432955E+09 0.00 0.00
February 0.00 0.00 0.00 0.129069E+09 0.00 0.00
March 0.00 0.00 0.00 0.156376E+09 0.00 0.00
April 0.00 0.00 0.00 0.651192E+09 0.00 0.00
May 0.00 0.00 0.00 0.737088E+09 0.00 0.00
June 0.00 0.00 0.00 0.104775E+10 0.00 0.00
July 0.00 0.00 0.00 0.126320E+10 0.00 0.00
August 0.00 0.00 0.00 0.126099E+10 0.00 0.00
September 0.00 0.00 0.00 0.124262E+10 0.00 0.00
October 0.00 0.00 0.00 0.879546E+09 0.00 0.00
November 0.00 0.00 0.00 0.574282E+09 0.00 0.00
December 0.00 0.00 0.00 0.418640E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.879371E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.129069E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.126320E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT MSW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.100754E+10 0.00 0.00
February 0.00 0.00 0.00 0.470926E+09 0.00 0.00
March 0.00 0.00 0.00 0.652801E+09 0.00 0.00
April 0.00 0.00 0.00 0.188390E+10 0.00 0.00
May 0.00 0.00 0.00 0.213985E+10 0.00 0.00
June 0.00 0.00 0.00 0.284265E+10 0.00 0.00
July 0.00 0.00 0.00 0.289835E+10 0.00 0.00
August 0.00 0.00 0.00 0.279338E+10 0.00 0.00
September 0.00 0.00 0.00 0.252731E+10 0.00 0.00
October 0.00 0.00 0.00 0.166101E+10 0.00 0.00
November 0.00 0.00 0.00 0.984958E+09 0.00 0.00
December 0.00 0.00 0.00 0.643722E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.205064E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.470926E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.289835E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT MNW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.221747E+09 0.00 0.00
February 0.00 0.00 0.00 78292919.04 0.00 0.00
March 0.00 0.00 0.00 0.367952E+09 0.00 0.00
April 0.00 0.00 0.00 0.164730E+10 0.00 0.00
May 0.00 0.00 0.00 0.226074E+10 0.00 0.00
June 0.00 0.00 0.00 0.312843E+10 0.00 0.00
July 0.00 0.00 0.00 0.307667E+10 0.00 0.00
August 0.00 0.00 0.00 0.283292E+10 0.00 0.00
September 0.00 0.00 0.00 0.233428E+10 0.00 0.00
October 0.00 0.00 0.00 0.110768E+10 0.00 0.00
November 0.00 0.00 0.00 0.331063E+09 0.00 0.00
December 0.00 0.00 0.00 60643968.83 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.174477E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 60643968.83 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.312843E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT MSE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.987583E+09 0.00 0.00
February 0.00 0.00 0.00 0.499362E+09 0.00 0.00
March 0.00 0.00 0.00 0.668324E+09 0.00 0.00
April 0.00 0.00 0.00 0.188179E+10 0.00 0.00
May 0.00 0.00 0.00 0.214609E+10 0.00 0.00
June 0.00 0.00 0.00 0.285307E+10 0.00 0.00
July 0.00 0.00 0.00 0.297121E+10 0.00 0.00
August 0.00 0.00 0.00 0.285726E+10 0.00 0.00
September 0.00 0.00 0.00 0.255363E+10 0.00 0.00
October 0.00 0.00 0.00 0.168067E+10 0.00 0.00
November 0.00 0.00 0.00 0.959511E+09 0.00 0.00
December 0.00 0.00 0.00 0.646093E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.207046E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.499362E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.297121E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT MNE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.203460E+09 0.00 0.00
February 0.00 0.00 0.00 0.100143E+09 0.00 0.00
March 0.00 0.00 0.00 0.381781E+09 0.00 0.00
April 0.00 0.00 0.00 0.164483E+10 0.00 0.00
May 0.00 0.00 0.00 0.227757E+10 0.00 0.00
June 0.00 0.00 0.00 0.314535E+10 0.00 0.00
July 0.00 0.00 0.00 0.315722E+10 0.00 0.00
August 0.00 0.00 0.00 0.290539E+10 0.00 0.00
September 0.00 0.00 0.00 0.236589E+10 0.00 0.00
October 0.00 0.00 0.00 0.112796E+10 0.00 0.00
November 0.00 0.00 0.00 0.300661E+09 0.00 0.00
December 0.00 0.00 0.00 55055944.40 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.176653E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 55055944.40 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.315722E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT MN1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.285520E+09 0.00 0.00
February 0.00 0.00 0.00 0.199824E+09 0.00 0.00
March 0.00 0.00 0.00 0.420624E+09 0.00 0.00
April 0.00 0.00 0.00 0.130582E+10 0.00 0.00
May 0.00 0.00 0.00 0.177452E+10 0.00 0.00
June 0.00 0.00 0.00 0.240079E+10 0.00 0.00
July 0.00 0.00 0.00 0.247139E+10 0.00 0.00
August 0.00 0.00 0.00 0.228304E+10 0.00 0.00
September 0.00 0.00 0.00 0.193052E+10 0.00 0.00
October 0.00 0.00 0.00 0.984794E+09 0.00 0.00
November 0.00 0.00 0.00 0.378509E+09 0.00 0.00
December 0.00 0.00 0.00 0.112668E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.145480E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.112668E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.247139E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT MN2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.284375E+09 0.00 0.00
February 0.00 0.00 0.00 0.203145E+09 0.00 0.00
March 0.00 0.00 0.00 0.423308E+09 0.00 0.00
April 0.00 0.00 0.00 0.131061E+10 0.00 0.00
May 0.00 0.00 0.00 0.177914E+10 0.00 0.00
June 0.00 0.00 0.00 0.240306E+10 0.00 0.00
July 0.00 0.00 0.00 0.247508E+10 0.00 0.00
August 0.00 0.00 0.00 0.228686E+10 0.00 0.00
September 0.00 0.00 0.00 0.193323E+10 0.00 0.00
October 0.00 0.00 0.00 0.988243E+09 0.00 0.00
November 0.00 0.00 0.00 0.377134E+09 0.00 0.00
December 0.00 0.00 0.00 0.113411E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.145776E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.113411E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.247508E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT MS1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.116076E+10 0.00 0.00
February 0.00 0.00 0.00 0.680581E+09 0.00 0.00
March 0.00 0.00 0.00 0.745232E+09 0.00 0.00
April 0.00 0.00 0.00 0.156326E+10 0.00 0.00
May 0.00 0.00 0.00 0.168317E+10 0.00 0.00
June 0.00 0.00 0.00 0.214919E+10 0.00 0.00
July 0.00 0.00 0.00 0.232503E+10 0.00 0.00
August 0.00 0.00 0.00 0.227748E+10 0.00 0.00
September 0.00 0.00 0.00 0.214936E+10 0.00 0.00
October 0.00 0.00 0.00 0.156456E+10 0.00 0.00
November 0.00 0.00 0.00 0.110310E+10 0.00 0.00
December 0.00 0.00 0.00 0.905442E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.183072E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.680581E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.232503E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT MS2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.116203E+10 0.00 0.00
February 0.00 0.00 0.00 0.685089E+09 0.00 0.00
March 0.00 0.00 0.00 0.749981E+09 0.00 0.00
April 0.00 0.00 0.00 0.156950E+10 0.00 0.00
May 0.00 0.00 0.00 0.168974E+10 0.00 0.00
June 0.00 0.00 0.00 0.215400E+10 0.00 0.00
July 0.00 0.00 0.00 0.233062E+10 0.00 0.00
August 0.00 0.00 0.00 0.228323E+10 0.00 0.00
September 0.00 0.00 0.00 0.215300E+10 0.00 0.00
October 0.00 0.00 0.00 0.156935E+10 0.00 0.00
November 0.00 0.00 0.00 0.110333E+10 0.00 0.00
December 0.00 0.00 0.00 0.908457E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.183583E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.685089E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.233062E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT TSW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.329512E+09 0.00 0.00
February 0.00 0.00 0.00 0.108651E+09 0.00 0.00
March 0.00 0.00 0.00 0.231347E+09 0.00 0.00
April 0.00 0.00 0.00 0.958064E+09 0.00 0.00
May 0.00 0.00 0.00 0.116709E+10 0.00 0.00
June 0.00 0.00 0.00 0.166267E+10 0.00 0.00
July 0.00 0.00 0.00 0.167060E+10 0.00 0.00
August 0.00 0.00 0.00 0.158704E+10 0.00 0.00
September 0.00 0.00 0.00 0.137819E+10 0.00 0.00
October 0.00 0.00 0.00 0.758374E+09 0.00 0.00
November 0.00 0.00 0.00 0.313421E+09 0.00 0.00
December 0.00 0.00 0.00 0.257464E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.104224E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.108651E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.167060E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT TNW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.107400E+09 0.00 0.00
February 0.00 0.00 0.00 65025169.25 0.00 0.00
March 0.00 0.00 0.00 0.157104E+09 0.00 0.00
April 0.00 0.00 0.00 0.838133E+09 0.00 0.00
May 0.00 0.00 0.00 0.122630E+10 0.00 0.00
June 0.00 0.00 0.00 0.181220E+10 0.00 0.00
July 0.00 0.00 0.00 0.176848E+10 0.00 0.00
August 0.00 0.00 0.00 0.160660E+10 0.00 0.00
September 0.00 0.00 0.00 0.127886E+10 0.00 0.00
October 0.00 0.00 0.00 0.506764E+09 0.00 0.00
November 0.00 0.00 0.00 0.127024E+09 0.00 0.00
December 0.00 0.00 0.00 0.249469E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.974335E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 65025169.25 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.181220E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT TSE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.308952E+09 0.00 0.00
February 0.00 0.00 0.00 0.106055E+09 0.00 0.00
March 0.00 0.00 0.00 0.222530E+09 0.00 0.00
April 0.00 0.00 0.00 0.945104E+09 0.00 0.00
May 0.00 0.00 0.00 0.116238E+10 0.00 0.00
June 0.00 0.00 0.00 0.166415E+10 0.00 0.00
July 0.00 0.00 0.00 0.170647E+10 0.00 0.00
August 0.00 0.00 0.00 0.161725E+10 0.00 0.00
September 0.00 0.00 0.00 0.138840E+10 0.00 0.00
October 0.00 0.00 0.00 0.758922E+09 0.00 0.00
November 0.00 0.00 0.00 0.295143E+09 0.00 0.00
December 0.00 0.00 0.00 0.240618E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.104160E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.106055E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.170647E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT TNE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 94620041.85 0.00 0.00
February 0.00 0.00 0.00 56796660.37 0.00 0.00
March 0.00 0.00 0.00 0.148188E+09 0.00 0.00
April 0.00 0.00 0.00 0.827346E+09 0.00 0.00
May 0.00 0.00 0.00 0.122748E+10 0.00 0.00
June 0.00 0.00 0.00 0.181684E+10 0.00 0.00
July 0.00 0.00 0.00 0.180767E+10 0.00 0.00
August 0.00 0.00 0.00 0.164129E+10 0.00 0.00
September 0.00 0.00 0.00 0.129195E+10 0.00 0.00
October 0.00 0.00 0.00 0.503597E+09 0.00 0.00
November 0.00 0.00 0.00 0.109539E+09 0.00 0.00
December 0.00 0.00 0.00 0.234193E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.975950E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 56796660.37 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.181684E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT TN1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 52944920.01 0.00 0.00
February 0.00 0.00 0.00 20485647.55 0.00 0.00
March 0.00 0.00 0.00 0.112397E+09 0.00 0.00
April 0.00 0.00 0.00 0.651410E+09 0.00 0.00
May 0.00 0.00 0.00 0.968808E+09 0.00 0.00
June 0.00 0.00 0.00 0.143019E+10 0.00 0.00
July 0.00 0.00 0.00 0.145312E+10 0.00 0.00
August 0.00 0.00 0.00 0.132028E+10 0.00 0.00
September 0.00 0.00 0.00 0.106811E+10 0.00 0.00
October 0.00 0.00 0.00 0.413860E+09 0.00 0.00
November 0.00 0.00 0.00 80608801.03 0.00 0.00
December 0.00 0.00 0.00 0.136882E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.770910E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 20485647.55 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.145312E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT TN2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 53661691.23 0.00 0.00
February 0.00 0.00 0.00 20470630.86 0.00 0.00
March 0.00 0.00 0.00 0.113121E+09 0.00 0.00
April 0.00 0.00 0.00 0.654559E+09 0.00 0.00
May 0.00 0.00 0.00 0.971692E+09 0.00 0.00
June 0.00 0.00 0.00 0.143149E+10 0.00 0.00
July 0.00 0.00 0.00 0.145523E+10 0.00 0.00
August 0.00 0.00 0.00 0.132247E+10 0.00 0.00
September 0.00 0.00 0.00 0.106968E+10 0.00 0.00
October 0.00 0.00 0.00 0.415855E+09 0.00 0.00
November 0.00 0.00 0.00 79958014.41 0.00 0.00
December 0.00 0.00 0.00 0.137177E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.772536E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 20470630.86 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.145523E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT TS1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.325818E+09 0.00 0.00
February 0.00 0.00 0.00 0.107493E+09 0.00 0.00
March 0.00 0.00 0.00 0.198677E+09 0.00 0.00
April 0.00 0.00 0.00 0.783578E+09 0.00 0.00
May 0.00 0.00 0.00 0.924311E+09 0.00 0.00
June 0.00 0.00 0.00 0.129802E+10 0.00 0.00
July 0.00 0.00 0.00 0.137174E+10 0.00 0.00
August 0.00 0.00 0.00 0.131965E+10 0.00 0.00
September 0.00 0.00 0.00 0.118267E+10 0.00 0.00
October 0.00 0.00 0.00 0.685889E+09 0.00 0.00
November 0.00 0.00 0.00 0.313630E+09 0.00 0.00
December 0.00 0.00 0.00 0.207920E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.871940E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.107493E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.137174E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: SPLIT TS2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.327497E+09 0.00 0.00
February 0.00 0.00 0.00 0.110034E+09 0.00 0.00
March 0.00 0.00 0.00 0.200544E+09 0.00 0.00
April 0.00 0.00 0.00 0.786993E+09 0.00 0.00
May 0.00 0.00 0.00 0.927997E+09 0.00 0.00
June 0.00 0.00 0.00 0.130049E+10 0.00 0.00
July 0.00 0.00 0.00 0.137470E+10 0.00 0.00
August 0.00 0.00 0.00 0.132270E+10 0.00 0.00
September 0.00 0.00 0.00 0.118460E+10 0.00 0.00
October 0.00 0.00 0.00 0.688751E+09 0.00 0.00
November 0.00 0.00 0.00 0.314518E+09 0.00 0.00
December 0.00 0.00 0.00 0.209212E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.874804E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.110034E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.137470E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT GSW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 82346605.43 0.103163E+10 0.00 0.00 0.00 0.00 0.00 0.00
February 14645891.62 0.183011E+09 0.00 0.00 0.00 0.00 0.00 0.00
March 24407174.58 0.308628E+09 0.00 0.00 0.00 0.00 0.00 0.00
April 0.163267E+09 0.197846E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.189836E+09 0.226249E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.279509E+09 0.332115E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.320861E+09 0.404210E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.322334E+09 0.409925E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.314776E+09 0.406857E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.213976E+09 0.270895E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.128599E+09 0.163283E+10 0.00 0.00 0.00 0.00 0.00 0.00
December 74819462.82 0.925447E+09 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.212938E+10 0.265625E+11 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 14645891.62 0.183011E+09 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.322334E+09 0.409925E+10 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT GNW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 11759494.28 0.125760E+09 13582686.20 0.00 0.00 0.00 0.00 0.00
February 279331.51 3390549.46 0.00 0.00 0.00 0.00 0.00 0.00
March 11273745.61 0.137931E+09 0.00 0.00 0.00 0.00 0.00 0.00
April 0.136637E+09 0.162594E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.203797E+09 0.239466E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.313536E+09 0.367754E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.343014E+09 0.426956E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.330393E+09 0.413620E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.297169E+09 0.378105E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.153699E+09 0.190791E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 51918849.79 0.651917E+09 0.00 0.00 0.00 0.00 0.00 0.00
December 7314810.24 88818552.31 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.186079E+10 0.228007E+11 13582686.20 0.00 0.00 0.00 0.00 0.00
Minimum of Months 279331.51 3390549.46 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.343014E+09 0.426956E+10 13582686.20 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT OFFICE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.118266E+10 0.112513E+10 0.00 0.00 0.00 0.00 0.00 0.00
February 0.105523E+10 0.466751E+09 0.00 0.00 0.00 0.00 0.00 0.00
March 0.116347E+10 0.681168E+09 167757.21 0.00 0.00 0.00 0.00 0.00
April 0.115154E+10 0.183781E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.119022E+10 0.231068E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.116147E+10 0.331500E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.120577E+10 0.362041E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.120382E+10 0.401077E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.116709E+10 0.352539E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.119647E+10 0.250212E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.114893E+10 0.158785E+10 0.00 0.00 0.00 0.00 0.00 0.00
December 0.117908E+10 0.870557E+09 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.140057E+11 0.258536E+11 167757.21 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.105523E+10 0.466751E+09 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.120577E+10 0.401077E+10 167757.21 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT GNE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 10419670.60 0.107937E+09 14861292.93 0.00 0.00 0.00 0.00 0.00
February 244080.63 2938571.95 0.00 0.00 0.00 0.00 0.00 0.00
March 11109126.77 0.136082E+09 0.00 0.00 0.00 0.00 0.00 0.00
April 0.136843E+09 0.163310E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.206208E+09 0.243412E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.315876E+09 0.372564E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.351479E+09 0.440104E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.338028E+09 0.425704E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.300390E+09 0.384205E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.155931E+09 0.194297E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 49050469.27 0.616017E+09 0.00 0.00 0.00 0.00 0.00 0.00
December 7186179.45 87060013.66 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.188276E+10 0.231860E+11 14861292.93 0.00 0.00 0.00 0.00 0.00
Minimum of Months 244080.63 2938571.95 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.351479E+09 0.440104E+10 14861292.93 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT GN1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 13614494.67 0.164710E+09 560798.29 0.00 0.00 0.00 0.00 0.00
February 737575.93 8895695.91 0.00 0.00 0.00 0.00 0.00 0.00
March 13650771.47 0.167455E+09 0.00 0.00 0.00 0.00 0.00 0.00
April 0.115719E+09 0.138027E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.172355E+09 0.203289E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.254447E+09 0.299190E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.284508E+09 0.356081E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.272421E+09 0.342963E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.246546E+09 0.315381E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.134204E+09 0.167166E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 53776868.44 0.675608E+09 0.00 0.00 0.00 0.00 0.00 0.00
December 12175652.53 0.147343E+09 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.157416E+10 0.193850E+11 560798.29 0.00 0.00 0.00 0.00 0.00
Minimum of Months 737575.93 8895695.91 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.284508E+09 0.356081E+10 560798.29 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT GN2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 13647324.26 0.164940E+09 665364.38 0.00 0.00 0.00 0.00 0.00
February 768193.44 9274635.82 0.00 0.00 0.00 0.00 0.00 0.00
March 13809173.47 0.169421E+09 0.00 0.00 0.00 0.00 0.00 0.00
April 0.116220E+09 0.138649E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.172828E+09 0.203884E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.254686E+09 0.299512E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.284929E+09 0.356666E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.272842E+09 0.343552E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.246805E+09 0.315757E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.134623E+09 0.167707E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 53527216.51 0.672475E+09 0.00 0.00 0.00 0.00 0.00 0.00
December 12232348.64 0.148031E+09 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.157692E+10 0.194214E+11 665364.38 0.00 0.00 0.00 0.00 0.00
Minimum of Months 768193.44 9274635.82 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.284929E+09 0.356666E+10 665364.38 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT GS1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.105362E+09 0.132448E+10 0.00 0.00 0.00 0.00 0.00 0.00
February 32051096.61 0.401953E+09 0.00 0.00 0.00 0.00 0.00 0.00
March 36897953.48 0.466074E+09 0.00 0.00 0.00 0.00 0.00 0.00
April 0.146546E+09 0.178497E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.162551E+09 0.194856E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.225249E+09 0.268904E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.267332E+09 0.339291E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.269894E+09 0.345835E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.268856E+09 0.350120E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.197953E+09 0.252154E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.136162E+09 0.173782E+10 0.00 0.00 0.00 0.00 0.00 0.00
December 0.100291E+09 0.124236E+10 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.194914E+10 0.244693E+11 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 32051096.61 0.401953E+09 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.269894E+09 0.350120E+10 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT GS2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.104949E+09 0.131911E+10 0.00 0.00 0.00 0.00 0.00 0.00
February 31184925.02 0.390982E+09 0.00 0.00 0.00 0.00 0.00 0.00
March 37640140.70 0.475441E+09 0.00 0.00 0.00 0.00 0.00 0.00
April 0.155892E+09 0.190146E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.175594E+09 0.210948E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.242900E+09 0.290878E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.288514E+09 0.366895E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.288289E+09 0.370086E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.286443E+09 0.373757E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.209069E+09 0.266778E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.138142E+09 0.176278E+10 0.00 0.00 0.00 0.00 0.00 0.00
December 99213912.27 0.122901E+10 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.205783E+10 0.258722E+11 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 31184925.02 0.390982E+09 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.288514E+09 0.373757E+10 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT MSW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.244177E+09 0.306607E+10 0.00 0.00 0.00 0.00 0.00 0.00
February 0.113512E+09 0.143317E+10 0.00 0.00 0.00 0.00 0.00 0.00
March 0.157184E+09 0.198375E+10 0.00 0.00 0.00 0.00 0.00 0.00
April 0.450111E+09 0.548738E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.508384E+09 0.609659E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.657591E+09 0.782072E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.660368E+09 0.827522E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.636438E+09 0.803843E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.580306E+09 0.742771E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.393463E+09 0.494581E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.237275E+09 0.300771E+10 0.00 0.00 0.00 0.00 0.00 0.00
December 0.156421E+09 0.193805E+10 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.479523E+10 0.595206E+11 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.113512E+09 0.143317E+10 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.660368E+09 0.827522E+10 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT MNW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 53505686.84 0.647220E+09 3965964.48 0.00 0.00 0.00 0.00 0.00
February 18832877.93 0.235888E+09 0.00 0.00 0.00 0.00 0.00 0.00
March 88342079.18 0.109441E+10 0.00 0.00 0.00 0.00 0.00 0.00
April 0.393086E+09 0.470639E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.536450E+09 0.634037E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.723777E+09 0.848760E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.700117E+09 0.865876E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.643710E+09 0.799320E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.535093E+09 0.673827E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.260454E+09 0.320386E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 79426494.69 0.995074E+09 0.00 0.00 0.00 0.00 0.00 0.00
December 14301781.81 0.168450E+09 3821860.16 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.404710E+10 0.492695E+11 7787824.64 0.00 0.00 0.00 0.00 0.00
Minimum of Months 14301781.81 0.168450E+09 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.723777E+09 0.865876E+10 3965964.48 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT MSE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.239310E+09 0.300877E+10 0.00 0.00 0.00 0.00 0.00 0.00
February 0.120287E+09 0.152261E+10 0.00 0.00 0.00 0.00 0.00 0.00
March 0.160907E+09 0.203338E+10 0.00 0.00 0.00 0.00 0.00 0.00
April 0.449418E+09 0.549194E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.509513E+09 0.612587E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.659534E+09 0.787163E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.676710E+09 0.852174E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.650770E+09 0.825606E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.586286E+09 0.753640E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.397977E+09 0.501703E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.231192E+09 0.293145E+10 0.00 0.00 0.00 0.00 0.00 0.00
December 0.156991E+09 0.194694E+10 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.483889E+10 0.602638E+11 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.120287E+09 0.152261E+10 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.676710E+09 0.852174E+10 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT MNE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 48894994.15 0.586762E+09 6811867.76 0.00 0.00 0.00 0.00 0.00
February 24036531.29 0.301896E+09 0.00 0.00 0.00 0.00 0.00 0.00
March 91677618.95 0.113729E+10 0.00 0.00 0.00 0.00 0.00 0.00
April 0.392493E+09 0.471693E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.540435E+09 0.642284E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.727718E+09 0.859056E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.718670E+09 0.894486E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.660477E+09 0.825334E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.542526E+09 0.686847E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.265217E+09 0.327606E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 72116348.10 0.903581E+09 0.00 0.00 0.00 0.00 0.00 0.00
December 13112205.45 0.155636E+09 2282770.23 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.409737E+10 0.501582E+11 9094637.99 0.00 0.00 0.00 0.00 0.00
Minimum of Months 13112205.45 0.155636E+09 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.727718E+09 0.894486E+10 6811867.76 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT MN1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 69265860.30 0.846795E+09 0.00 0.00 0.00 0.00 0.00 0.00
February 47953527.68 0.602808E+09 0.00 0.00 0.00 0.00 0.00 0.00
March 0.101128E+09 0.125582E+10 0.00 0.00 0.00 0.00 0.00 0.00
April 0.311991E+09 0.373669E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.421486E+09 0.498633E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.555763E+09 0.651918E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.562470E+09 0.698941E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.519119E+09 0.648185E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.442925E+09 0.561012E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.232217E+09 0.286629E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 90985083.80 0.114005E+10 0.00 0.00 0.00 0.00 0.00 0.00
December 27446249.19 0.331959E+09 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.338275E+10 0.413673E+11 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 27446249.19 0.331959E+09 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.562470E+09 0.698941E+10 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT MN2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 68989303.60 0.843369E+09 0.00 0.00 0.00 0.00 0.00 0.00
February 48749839.70 0.612864E+09 0.00 0.00 0.00 0.00 0.00 0.00
March 0.101773E+09 0.126402E+10 0.00 0.00 0.00 0.00 0.00 0.00
April 0.313130E+09 0.375116E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.422576E+09 0.500028E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.556279E+09 0.652615E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.563308E+09 0.700082E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.519986E+09 0.649369E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.443545E+09 0.561876E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.233036E+09 0.287671E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 90657889.11 0.113574E+10 0.00 0.00 0.00 0.00 0.00 0.00
December 27627227.83 0.334148E+09 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.338966E+10 0.414577E+11 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 27627227.83 0.334148E+09 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.563308E+09 0.700082E+10 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT MS1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.281288E+09 0.354885E+10 0.00 0.00 0.00 0.00 0.00 0.00
February 0.163879E+09 0.208045E+10 0.00 0.00 0.00 0.00 0.00 0.00
March 0.179254E+09 0.226842E+10 0.00 0.00 0.00 0.00 0.00 0.00
April 0.374189E+09 0.457557E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.400770E+09 0.481896E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.498183E+09 0.593640E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.530473E+09 0.669057E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.520112E+09 0.661619E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.494433E+09 0.637584E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.371685E+09 0.470040E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.265888E+09 0.338293E+10 0.00 0.00 0.00 0.00 0.00 0.00
December 0.218364E+09 0.270908E+10 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.429852E+10 0.537037E+11 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.163879E+09 0.208045E+10 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.530473E+09 0.669057E+10 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT MS2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.281593E+09 0.355293E+10 0.00 0.00 0.00 0.00 0.00 0.00
February 0.164962E+09 0.209446E+10 0.00 0.00 0.00 0.00 0.00 0.00
March 0.180395E+09 0.228316E+10 0.00 0.00 0.00 0.00 0.00 0.00
April 0.375666E+09 0.459436E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.402308E+09 0.483823E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.499269E+09 0.594992E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.531730E+09 0.670735E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.521406E+09 0.663355E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.495259E+09 0.638724E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.372819E+09 0.471524E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.265944E+09 0.338362E+10 0.00 0.00 0.00 0.00 0.00 0.00
December 0.219110E+09 0.271847E+10 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.431046E+10 0.538585E+11 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.164962E+09 0.209446E+10 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.531730E+09 0.670735E+10 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT TSW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 78795762.30 0.963442E+09 28979852.31 0.00 0.00 0.00 0.00 0.00
February 25625284.20 0.284162E+09 41713229.35 0.00 0.00 0.00 0.00 0.00
March 54122048.97 0.633698E+09 47071939.93 0.00 0.00 0.00 0.00 0.00
April 0.227246E+09 0.276292E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.275164E+09 0.328171E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.381907E+09 0.451607E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.377985E+09 0.471122E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.358354E+09 0.449993E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.313898E+09 0.399719E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.177654E+09 0.223401E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 74643699.11 0.932336E+09 19771497.23 0.00 0.00 0.00 0.00 0.00
December 57628176.61 0.485611E+09 0.191958E+09 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.240302E+10 0.293023E+11 0.329495E+09 0.00 0.00 0.00 0.00 0.00
Minimum of Months 25625284.20 0.284162E+09 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.381907E+09 0.471122E+10 0.191958E+09 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT TNW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 23482048.28 0.136376E+09 0.141747E+09 0.00 0.00 0.00 0.00 0.00
February 13434315.41 7560207.70 0.161058E+09 0.00 0.00 0.00 0.00 0.00
March 35730289.32 0.343289E+09 89234637.57 0.00 0.00 0.00 0.00 0.00
April 0.199218E+09 0.237952E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.290026E+09 0.341796E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.418125E+09 0.489424E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.401353E+09 0.494963E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.363864E+09 0.450120E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.292134E+09 0.366265E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.118077E+09 0.144161E+10 7050654.70 0.00 0.00 0.00 0.00 0.00
November 28541604.53 0.244062E+09 0.104839E+09 0.00 0.00 0.00 0.00 0.00
December 50805552.92 24640577.03 0.537055E+09 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.223479E+10 0.260027E+11 0.104098E+10 0.00 0.00 0.00 0.00 0.00
Minimum of Months 13434315.41 7560207.70 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.418125E+09 0.494963E+10 0.537055E+09 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT TSE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 73799998.61 0.901369E+09 28678016.99 0.00 0.00 0.00 0.00 0.00
February 25002978.53 0.279830E+09 38910412.98 0.00 0.00 0.00 0.00 0.00
March 52030528.52 0.612670E+09 42259588.92 0.00 0.00 0.00 0.00 0.00
April 0.224017E+09 0.273230E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.273809E+09 0.327680E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.381949E+09 0.453906E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.385979E+09 0.484119E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.365074E+09 0.461138E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.316243E+09 0.404975E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.177658E+09 0.224284E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 70280431.24 0.876182E+09 18716972.52 0.00 0.00 0.00 0.00 0.00
December 53718502.39 0.449275E+09 0.181223E+09 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.239956E+10 0.294126E+11 0.309788E+09 0.00 0.00 0.00 0.00 0.00
Minimum of Months 25002978.53 0.279830E+09 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.385979E+09 0.484119E+10 0.181223E+09 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT TNE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 20464040.52 0.101827E+09 0.138503E+09 0.00 0.00 0.00 0.00 0.00
February 11713956.07 2723888.13 0.143523E+09 0.00 0.00 0.00 0.00 0.00
March 33705558.81 0.325511E+09 81663096.18 0.00 0.00 0.00 0.00 0.00
April 0.196661E+09 0.235929E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.290361E+09 0.344466E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.419301E+09 0.494840E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.410469E+09 0.510202E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.371980E+09 0.463712E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.295292E+09 0.372686E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.117287E+09 0.144129E+10 5096511.69 0.00 0.00 0.00 0.00 0.00
November 24467147.19 0.200416E+09 97154861.94 0.00 0.00 0.00 0.00 0.00
December 47776753.29 16966476.04 0.503026E+09 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.223948E+10 0.263071E+11 0.968966E+09 0.00 0.00 0.00 0.00 0.00
Minimum of Months 11713956.07 2723888.13 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.419301E+09 0.510202E+10 0.503026E+09 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT TN1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 11612375.87 84581229.84 50007952.81 0.00 0.00 0.00 0.00 0.00
February 4289280.11 5729806.54 47308622.07 0.00 0.00 0.00 0.00 0.00
March 25828492.07 0.286273E+09 28201798.12 0.00 0.00 0.00 0.00 0.00
April 0.154958E+09 0.184595E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.229300E+09 0.269889E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.330125E+09 0.386126E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.329887E+09 0.408161E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.299259E+09 0.371580E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.244246E+09 0.307482E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 96545175.97 0.118706E+10 49224.93 0.00 0.00 0.00 0.00 0.00
November 18440130.83 0.196486E+09 30882628.92 0.00 0.00 0.00 0.00 0.00
December 26823576.87 11810854.07 0.273518E+09 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.177132E+10 0.210503E+11 0.429968E+09 0.00 0.00 0.00 0.00 0.00
Minimum of Months 4289280.11 5729806.54 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.330125E+09 0.408161E+10 0.273518E+09 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT TN2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 11773278.75 85485312.43 51025858.60 0.00 0.00 0.00 0.00 0.00
February 4288005.90 5924786.96 47118773.20 0.00 0.00 0.00 0.00 0.00
March 26001853.14 0.288492E+09 28212617.94 0.00 0.00 0.00 0.00 0.00
April 0.155705E+09 0.185562E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.229980E+09 0.270792E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.330419E+09 0.386588E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.330367E+09 0.408869E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.299757E+09 0.372305E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.244604E+09 0.308015E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 97015157.64 0.119317E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 18266827.21 0.193571E+09 31376566.43 0.00 0.00 0.00 0.00 0.00
December 26898695.37 12088035.11 0.273904E+09 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.177508E+10 0.211000E+11 0.431638E+09 0.00 0.00 0.00 0.00 0.00
Minimum of Months 4288005.90 5924786.96 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.330419E+09 0.408869E+10 0.273904E+09 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT TS1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 78360199.94 0.986036E+09 7766327.30 0.00 0.00 0.00 0.00 0.00
February 25848164.93 0.325333E+09 4354363.09 0.00 0.00 0.00 0.00 0.00
March 47144771.88 0.589538E+09 9236182.65 0.00 0.00 0.00 0.00 0.00
April 0.186064E+09 0.225966E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.218213E+09 0.259825E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.298456E+09 0.352402E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.310640E+09 0.388507E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.298465E+09 0.376159E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.269774E+09 0.344988E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.161023E+09 0.203094E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 75177298.50 0.959864E+09 3547409.95 0.00 0.00 0.00 0.00 0.00
December 48023063.24 0.533834E+09 53917735.26 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.201719E+10 0.249040E+11 78822018.25 0.00 0.00 0.00 0.00 0.00
Minimum of Months 25848164.93 0.325333E+09 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.310640E+09 0.388507E+10 53917735.26 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: SPLIT TS2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 78760724.81 0.991272E+09 7840144.50 0.00 0.00 0.00 0.00 0.00
February 26454475.09 0.333034E+09 4477494.58 0.00 0.00 0.00 0.00 0.00
March 47589745.75 0.595368E+09 9224889.19 0.00 0.00 0.00 0.00 0.00
April 0.186860E+09 0.227013E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.219060E+09 0.260906E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.298997E+09 0.353123E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.311294E+09 0.389423E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.299136E+09 0.377100E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.270203E+09 0.345626E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.161693E+09 0.203996E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 75390748.34 0.962513E+09 3588686.01 0.00 0.00 0.00 0.00 0.00
December 48339054.42 0.538325E+09 53559084.17 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.202378E+10 0.249924E+11 78690298.45 0.00 0.00 0.00 0.00 0.00
Minimum of Months 26454475.09 0.333034E+09 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.311294E+09 0.389423E+10 53559084.17 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT GSW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 82346605.43 0.00 0.00 0.00 0.257320E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 14645891.62 0.00 0.00 0.00 45758422.82 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 24407174.58 0.00 0.00 0.00 77164512.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.163267E+09 0.00 0.00 0.00 0.520185E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.189836E+09 0.00 0.00 0.00 0.609034E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.279509E+09 0.00 0.00 0.00 0.928774E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.320861E+09 0.00 0.00 0.00 0.108648E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.322334E+09 0.00 0.00 0.00 0.109073E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.314776E+09 0.00 0.00 0.00 0.105320E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.213976E+09 0.00 0.00 0.00 0.688004E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.128599E+09 0.00 0.00 1809916.51 0.404552E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 74819462.82 0.00 0.00 3562561.29 0.232291E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.212938E+10 0.00 0.00 5372477.80 0.699349E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 14645891.62 0.00 0.00 0.00 45758422.82 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.322334E+09 0.00 0.00 3562561.29 0.109073E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT GNW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 11759494.28 0.00 0.00 7121182.70 32493464.15 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 279331.51 0.00 0.00 0.00 866667.84 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 11273745.61 0.00 0.00 0.00 35904587.31 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.136637E+09 0.00 0.00 0.00 0.436798E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.203797E+09 0.00 0.00 0.00 0.655720E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.313536E+09 0.00 0.00 0.00 0.104207E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.343014E+09 0.00 0.00 0.00 0.116320E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.330393E+09 0.00 0.00 0.00 0.112158E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.297169E+09 0.00 0.00 0.00 0.996258E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.153699E+09 0.00 0.00 0.00 0.498119E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 51918849.79 0.00 0.00 0.00 0.164174E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 7314810.24 0.00 0.00 0.00 22729889.58 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.186079E+10 0.00 0.00 7121182.70 0.616991E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 279331.51 0.00 0.00 0.00 866667.84 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.343014E+09 0.00 0.00 7121182.70 0.116320E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT OFFICE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.118266E+10 0.00 0.00 2160000.00 0.281113E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.105523E+10 0.00 0.00 0.00 0.117927E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.116347E+10 0.00 0.00 3895752.16 0.173390E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.115154E+10 0.00 0.00 0.00 0.475000E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.119022E+10 0.00 0.00 0.00 0.612091E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.116147E+10 0.00 0.00 0.00 0.915795E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.120577E+10 0.00 0.00 0.00 0.960266E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.120382E+10 0.00 0.00 0.00 0.105915E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.116709E+10 0.00 0.00 0.00 0.901349E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.119647E+10 0.00 0.00 0.00 0.628977E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.114893E+10 0.00 0.00 2370000.00 0.391192E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.117908E+10 0.00 0.00 16048182.81 0.218580E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.140057E+11 0.00 0.00 24473934.98 0.673484E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.105523E+10 0.00 0.00 0.00 0.117927E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.120577E+10 0.00 0.00 16048182.81 0.105915E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT GNE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 10419670.60 0.00 0.00 7577577.55 27919449.26 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 244080.63 0.00 0.00 0.00 759319.77 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 11109126.77 0.00 0.00 0.00 35382451.34 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.136843E+09 0.00 0.00 0.00 0.437440E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.206208E+09 0.00 0.00 0.00 0.663463E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.315876E+09 0.00 0.00 0.00 0.104985E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.351479E+09 0.00 0.00 0.00 0.119159E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.338028E+09 0.00 0.00 0.00 0.114700E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.300390E+09 0.00 0.00 0.00 0.100676E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.155931E+09 0.00 0.00 0.00 0.505370E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 49050469.27 0.00 0.00 0.00 0.155129E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 7186179.45 0.00 0.00 0.00 22326577.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.188276E+10 0.00 0.00 7577577.55 0.624299E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 244080.63 0.00 0.00 0.00 759319.77 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.351479E+09 0.00 0.00 7577577.55 0.119159E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT GN1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 13614494.67 0.00 0.00 1096632.32 42241680.44 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 737575.93 0.00 0.00 0.00 2292753.82 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 13650771.47 0.00 0.00 0.00 43324037.81 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.115719E+09 0.00 0.00 0.00 0.369209E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.172355E+09 0.00 0.00 0.00 0.553662E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.254447E+09 0.00 0.00 0.00 0.844943E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.284508E+09 0.00 0.00 0.00 0.964716E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.272421E+09 0.00 0.00 0.00 0.924339E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.246546E+09 0.00 0.00 0.00 0.826196E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.134204E+09 0.00 0.00 0.00 0.434037E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 53776868.44 0.00 0.00 324902.44 0.169773E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 12175652.53 0.00 0.00 89205.10 37797935.08 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.157416E+10 0.00 0.00 1510739.87 0.521253E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 737575.93 0.00 0.00 0.00 2292753.82 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.284508E+09 0.00 0.00 1096632.32 0.964716E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT GN2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 13647324.26 0.00 0.00 1180930.37 42304676.04 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 768193.44 0.00 0.00 0.00 2389157.77 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 13809173.47 0.00 0.00 0.00 43825279.02 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.116220E+09 0.00 0.00 0.00 0.370811E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.172828E+09 0.00 0.00 0.00 0.555189E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.254686E+09 0.00 0.00 0.00 0.845750E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.284929E+09 0.00 0.00 0.00 0.966147E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.272842E+09 0.00 0.00 0.00 0.925767E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.246805E+09 0.00 0.00 0.00 0.827065E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.134623E+09 0.00 0.00 0.00 0.435372E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 53527216.51 0.00 0.00 324954.04 0.168990E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 12232348.64 0.00 0.00 89153.09 37973891.65 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.157692E+10 0.00 0.00 1595037.50 0.522158E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 768193.44 0.00 0.00 0.00 2389157.77 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.284929E+09 0.00 0.00 1180930.37 0.966147E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT GS1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.105362E+09 0.00 0.00 0.00 0.329291E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 32051096.61 0.00 0.00 0.00 0.100609E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 36897953.48 0.00 0.00 0.00 0.116388E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.146546E+09 0.00 0.00 0.00 0.465667E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.162551E+09 0.00 0.00 0.00 0.519898E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.225249E+09 0.00 0.00 0.00 0.746586E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.267332E+09 0.00 0.00 0.00 0.903887E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.269894E+09 0.00 0.00 0.00 0.911259E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.268856E+09 0.00 0.00 0.00 0.898216E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.197953E+09 0.00 0.00 0.00 0.634843E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.136162E+09 0.00 0.00 2049631.13 0.427856E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.100291E+09 0.00 0.00 12368573.29 0.311123E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.194914E+10 0.00 0.00 14418204.42 0.636562E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 32051096.61 0.00 0.00 0.00 0.100609E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.269894E+09 0.00 0.00 12368573.29 0.911259E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT GS2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.104949E+09 0.00 0.00 0.00 0.328006E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 31184925.02 0.00 0.00 0.00 97883794.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 37640140.70 0.00 0.00 0.00 0.118736E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.155892E+09 0.00 0.00 0.00 0.495300E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.175594E+09 0.00 0.00 0.00 0.561493E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.242900E+09 0.00 0.00 0.00 0.804848E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.288514E+09 0.00 0.00 0.00 0.974687E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.288289E+09 0.00 0.00 0.00 0.972700E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.286443E+09 0.00 0.00 0.00 0.956180E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.209069E+09 0.00 0.00 0.00 0.670477E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.138142E+09 0.00 0.00 2052713.56 0.434087E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 99213912.27 0.00 0.00 11614218.64 0.307812E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.205783E+10 0.00 0.00 13666932.20 0.672221E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 31184925.02 0.00 0.00 0.00 97883794.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.288514E+09 0.00 0.00 11614218.64 0.974687E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT MSW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.244177E+09 0.00 0.00 0.00 0.763359E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.113512E+09 0.00 0.00 0.00 0.357415E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.157184E+09 0.00 0.00 0.00 0.495617E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.450111E+09 0.00 0.00 0.00 0.143378E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.508384E+09 0.00 0.00 0.00 0.163146E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.657591E+09 0.00 0.00 0.00 0.218506E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.660368E+09 0.00 0.00 0.00 0.223798E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.636438E+09 0.00 0.00 0.00 0.215694E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.580306E+09 0.00 0.00 0.00 0.194701E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.393463E+09 0.00 0.00 0.00 0.126755E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.237275E+09 0.00 0.00 990411.74 0.746692E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.156421E+09 0.00 0.00 1595241.02 0.485706E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.479523E+10 0.00 0.00 2585652.75 0.157086E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.113512E+09 0.00 0.00 0.00 0.357415E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.660368E+09 0.00 0.00 1595241.02 0.223798E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT MNW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 53505686.84 0.00 0.00 2763118.90 0.165478E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 18832877.93 0.00 0.00 0.00 59460041.11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 88342079.18 0.00 0.00 0.00 0.279610E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.393086E+09 0.00 0.00 0.00 0.125422E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.536450E+09 0.00 0.00 0.00 0.172429E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.723777E+09 0.00 0.00 0.00 0.240465E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.700117E+09 0.00 0.00 0.00 0.237655E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.643710E+09 0.00 0.00 0.00 0.218921E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.535093E+09 0.00 0.00 0.00 0.179919E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.260454E+09 0.00 0.00 0.00 0.847230E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 79426494.69 0.00 0.00 0.00 0.251637E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 14301781.81 0.00 0.00 3180275.37 43161911.65 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.404710E+10 0.00 0.00 5943394.27 0.133947E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 14301781.81 0.00 0.00 0.00 43161911.65 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.723777E+09 0.00 0.00 3180275.37 0.240465E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT MSE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.239310E+09 0.00 0.00 0.00 0.748274E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.120287E+09 0.00 0.00 0.00 0.379076E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.160907E+09 0.00 0.00 0.00 0.507418E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.449418E+09 0.00 0.00 0.00 0.143237E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.509513E+09 0.00 0.00 0.00 0.163658E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.659534E+09 0.00 0.00 0.00 0.219353E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.676710E+09 0.00 0.00 0.00 0.229450E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.650770E+09 0.00 0.00 0.00 0.220649E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.586286E+09 0.00 0.00 0.00 0.196734E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.397977E+09 0.00 0.00 0.00 0.128270E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.231192E+09 0.00 0.00 994508.64 0.727325E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.156991E+09 0.00 0.00 1694809.66 0.487407E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.483889E+10 0.00 0.00 2689318.30 0.158630E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.120287E+09 0.00 0.00 0.00 0.379076E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.676710E+09 0.00 0.00 1694809.66 0.229450E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT MNE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 48894994.15 0.00 0.00 4313391.80 0.150251E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 24036531.29 0.00 0.00 0.00 76106530.54 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 91677618.95 0.00 0.00 0.00 0.290103E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.392493E+09 0.00 0.00 0.00 0.125234E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.540435E+09 0.00 0.00 0.00 0.173714E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.727718E+09 0.00 0.00 0.00 0.241763E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.718670E+09 0.00 0.00 0.00 0.243855E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.660477E+09 0.00 0.00 0.00 0.224491E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.542526E+09 0.00 0.00 0.00 0.182337E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.265217E+09 0.00 0.00 0.00 0.862744E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 72116348.10 0.00 0.00 0.00 0.228545E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 13112205.45 0.00 0.00 2009129.77 39934609.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.409737E+10 0.00 0.00 6322521.57 0.135616E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 13112205.45 0.00 0.00 0.00 39934609.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.727718E+09 0.00 0.00 4313391.80 0.243855E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT MN1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 69265860.30 0.00 0.00 0.00 0.216254E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 47953527.68 0.00 0.00 0.00 0.151871E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.101128E+09 0.00 0.00 0.00 0.319496E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.311991E+09 0.00 0.00 0.00 0.993833E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.421486E+09 0.00 0.00 0.00 0.135304E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.555763E+09 0.00 0.00 0.00 0.184503E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.562470E+09 0.00 0.00 0.00 0.190892E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.519119E+09 0.00 0.00 0.00 0.176392E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.442925E+09 0.00 0.00 0.00 0.148760E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.232217E+09 0.00 0.00 0.00 0.752577E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 90985083.80 0.00 0.00 0.00 0.287524E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 27446249.19 0.00 0.00 29784.89 85192372.47 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.338275E+10 0.00 0.00 29784.89 0.111653E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 27446249.19 0.00 0.00 0.00 85192372.47 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.562470E+09 0.00 0.00 29784.89 0.190892E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT MN2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 68989303.60 0.00 0.00 0.00 0.215386E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 48749839.70 0.00 0.00 0.00 0.154395E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.101773E+09 0.00 0.00 0.00 0.321534E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.313130E+09 0.00 0.00 0.00 0.997482E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.422576E+09 0.00 0.00 0.00 0.135656E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.556279E+09 0.00 0.00 0.00 0.184678E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.563308E+09 0.00 0.00 0.00 0.191177E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.519986E+09 0.00 0.00 0.00 0.176687E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.443545E+09 0.00 0.00 0.00 0.148968E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.233036E+09 0.00 0.00 0.00 0.755207E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 90657889.11 0.00 0.00 0.00 0.286476E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 27627227.83 0.00 0.00 29762.49 85753981.95 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.338966E+10 0.00 0.00 29762.49 0.111879E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 27627227.83 0.00 0.00 0.00 85753981.95 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.563308E+09 0.00 0.00 29762.49 0.191177E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT MS1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.281288E+09 0.00 0.00 148102.96 0.879326E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.163879E+09 0.00 0.00 0.00 0.516702E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.179254E+09 0.00 0.00 1501836.39 0.564477E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.374189E+09 0.00 0.00 0.00 0.118907E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.400770E+09 0.00 0.00 0.00 0.128240E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.498183E+09 0.00 0.00 0.00 0.165101E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.530473E+09 0.00 0.00 0.00 0.179456E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.520112E+09 0.00 0.00 0.00 0.175737E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.494433E+09 0.00 0.00 0.00 0.165492E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.371685E+09 0.00 0.00 0.00 0.119288E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.265888E+09 0.00 0.00 1783271.24 0.835431E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.218364E+09 0.00 0.00 9669321.94 0.677409E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.429852E+10 0.00 0.00 13102532.53 0.139955E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.163879E+09 0.00 0.00 0.00 0.516702E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.530473E+09 0.00 0.00 9669321.94 0.179456E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT MS2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.281593E+09 0.00 0.00 148174.30 0.880293E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.164962E+09 0.00 0.00 0.00 0.520127E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.180395E+09 0.00 0.00 1501364.98 0.568085E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.375666E+09 0.00 0.00 0.00 0.119383E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.402308E+09 0.00 0.00 0.00 0.128743E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.499269E+09 0.00 0.00 0.00 0.165473E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.531730E+09 0.00 0.00 0.00 0.179889E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.521406E+09 0.00 0.00 0.00 0.176183E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.495259E+09 0.00 0.00 0.00 0.165774E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.372819E+09 0.00 0.00 0.00 0.119654E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.265944E+09 0.00 0.00 1783150.43 0.835606E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.219110E+09 0.00 0.00 9620894.80 0.679725E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.431046E+10 0.00 0.00 13053584.52 0.140348E+11 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.164962E+09 0.00 0.00 0.00 0.520127E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.531730E+09 0.00 0.00 9620894.80 0.179889E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT TSW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 78795762.30 0.00 0.00 12713167.67 0.238003E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 25625284.20 0.00 0.00 12935443.31 70089961.25 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 54122048.97 0.00 0.00 19492252.74 0.157733E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.227246E+09 0.00 0.00 0.00 0.730818E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.275164E+09 0.00 0.00 0.00 0.891925E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.381907E+09 0.00 0.00 0.00 0.128076E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.377985E+09 0.00 0.00 0.00 0.129262E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.358354E+09 0.00 0.00 0.00 0.122869E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.313898E+09 0.00 0.00 0.00 0.106429E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.177654E+09 0.00 0.00 0.00 0.580720E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 74643699.11 0.00 0.00 8333885.89 0.230444E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 57628176.61 0.00 0.00 79702281.32 0.120134E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.240302E+10 0.00 0.00 0.133177E+09 0.788622E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 25625284.20 0.00 0.00 0.00 70089961.25 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.381907E+09 0.00 0.00 79702281.32 0.129262E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT TNW

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 23482048.28 0.00 0.00 48368147.05 35549690.76 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 13434315.41 0.00 0.00 49684851.21 1906002.64 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 35730289.32 0.00 0.00 33210063.15 88163665.27 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.199218E+09 0.00 0.00 0.00 0.638914E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.290026E+09 0.00 0.00 0.00 0.936272E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.418125E+09 0.00 0.00 0.00 0.139408E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.401353E+09 0.00 0.00 0.00 0.136712E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.363864E+09 0.00 0.00 0.00 0.124274E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.292134E+09 0.00 0.00 0.00 0.986722E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.118077E+09 0.00 0.00 2164973.41 0.386522E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 28541604.53 0.00 0.00 35896719.49 62585825.81 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 50805552.92 0.00 0.00 0.192206E+09 6457248.85 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.223479E+10 0.00 0.00 0.361531E+09 0.714703E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 13434315.41 0.00 0.00 0.00 1906002.64 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.418125E+09 0.00 0.00 0.192206E+09 0.139408E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT TSE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 73799998.61 0.00 0.00 12597914.24 0.222554E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 25002978.53 0.00 0.00 12037010.18 69015144.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 52030528.52 0.00 0.00 18051344.29 0.152448E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.224017E+09 0.00 0.00 0.00 0.721087E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.273809E+09 0.00 0.00 0.00 0.888571E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.381949E+09 0.00 0.00 0.00 0.128220E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.385979E+09 0.00 0.00 0.00 0.132049E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.365074E+09 0.00 0.00 0.00 0.125217E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.316243E+09 0.00 0.00 0.00 0.107215E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.177658E+09 0.00 0.00 0.00 0.581264E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 70280431.24 0.00 0.00 7939615.35 0.216923E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 53718502.39 0.00 0.00 75996874.81 0.110903E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.239956E+10 0.00 0.00 0.126623E+09 0.788978E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 25002978.53 0.00 0.00 0.00 69015144.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.385979E+09 0.00 0.00 75996874.81 0.132049E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT TNE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 20464040.52 0.00 0.00 47590674.31 26565327.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 11713956.07 0.00 0.00 44407730.65 674973.66 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 33705558.81 0.00 0.00 30925679.77 83556294.84 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.196661E+09 0.00 0.00 0.00 0.630685E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.290361E+09 0.00 0.00 0.00 0.937120E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.419301E+09 0.00 0.00 0.00 0.139754E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.410469E+09 0.00 0.00 0.00 0.139720E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.371980E+09 0.00 0.00 0.00 0.126931E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.295292E+09 0.00 0.00 0.00 0.996657E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.117287E+09 0.00 0.00 1580941.84 0.384729E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 24467147.19 0.00 0.00 33584021.26 51487747.79 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 47776753.29 0.00 0.00 0.181953E+09 4464002.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.223948E+10 0.00 0.00 0.340042E+09 0.717998E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 11713956.07 0.00 0.00 0.00 674973.66 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.419301E+09 0.00 0.00 0.181953E+09 0.139754E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT TN1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 11612375.87 0.00 0.00 19307848.59 22024695.54 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 4289280.11 0.00 0.00 14774231.73 1422135.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 25828492.07 0.00 0.00 13032784.88 73535791.45 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.154958E+09 0.00 0.00 0.00 0.496452E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.229300E+09 0.00 0.00 0.00 0.739508E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.330125E+09 0.00 0.00 0.00 0.110007E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.329887E+09 0.00 0.00 0.00 0.112323E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.299259E+09 0.00 0.00 0.00 0.102102E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.244246E+09 0.00 0.00 0.00 0.823867E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 96545175.97 0.00 0.00 15092.41 0.317299E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 18440130.83 0.00 0.00 12150739.88 50017930.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 26823576.87 0.00 0.00 0.106945E+09 3113494.47 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.177132E+10 0.00 0.00 0.166226E+09 0.577156E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 4289280.11 0.00 0.00 0.00 1422135.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.330125E+09 0.00 0.00 0.106945E+09 0.112323E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT TN2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 11773278.75 0.00 0.00 19640592.17 22247820.31 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 4288005.90 0.00 0.00 14713469.02 1469155.93 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 26001853.14 0.00 0.00 13035499.73 74083951.76 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.155705E+09 0.00 0.00 0.00 0.498854E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.229980E+09 0.00 0.00 0.00 0.741712E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.330419E+09 0.00 0.00 0.00 0.110107E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.330367E+09 0.00 0.00 0.00 0.112486E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.299757E+09 0.00 0.00 0.00 0.102271E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.244604E+09 0.00 0.00 0.00 0.825072E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 97015157.64 0.00 0.00 0.00 0.318840E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 18266827.21 0.00 0.00 12366509.68 49324677.52 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 26898695.37 0.00 0.00 0.107091E+09 3187233.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.177508E+10 0.00 0.00 0.166847E+09 0.578344E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 4288005.90 0.00 0.00 0.00 1469155.93 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.330419E+09 0.00 0.00 0.107091E+09 0.112486E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT TS1

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 78360199.94 0.00 0.00 4454482.21 0.243003E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 25848164.93 0.00 0.00 1347239.70 80297731.22 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 47144771.88 0.00 0.00 5025109.41 0.146507E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.186064E+09 0.00 0.00 0.00 0.597513E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.218213E+09 0.00 0.00 0.00 0.706099E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.298456E+09 0.00 0.00 0.00 0.999563E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.310640E+09 0.00 0.00 0.00 0.106110E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.298465E+09 0.00 0.00 0.00 0.102119E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.269774E+09 0.00 0.00 0.00 0.912900E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.161023E+09 0.00 0.00 0.00 0.524866E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 75177298.50 0.00 0.00 1638243.77 0.236815E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 48023063.24 0.00 0.00 28089424.85 0.131807E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.201719E+10 0.00 0.00 40554499.94 0.666166E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 25848164.93 0.00 0.00 0.00 80297731.22 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.310640E+09 0.00 0.00 28089424.85 0.106110E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: SPLIT TS2

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 78760724.81 0.00 0.00 4481436.47 0.244255E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 26454475.09 0.00 0.00 1384518.36 82195011.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 47589745.75 0.00 0.00 5024549.05 0.147929E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.186860E+09 0.00 0.00 0.00 0.600132E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.219060E+09 0.00 0.00 0.00 0.708937E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.298997E+09 0.00 0.00 0.00 0.100149E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.311294E+09 0.00 0.00 0.00 0.106341E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.299136E+09 0.00 0.00 0.00 0.102356E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.270203E+09 0.00 0.00 0.00 0.914395E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.161693E+09 0.00 0.00 0.00 0.527058E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 75390748.34 0.00 0.00 1651791.22 0.237476E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 48339054.42 0.00 0.00 27965045.72 0.132908E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.202378E+10 0.00 0.00 40507340.81 0.668375E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 26454475.09 0.00 0.00 0.00 82195011.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.311294E+09 0.00 0.00 27965045.72 0.106341E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: G SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 82433067.99 248226.93 0.00 3977466.30 417394.91 0.00 0.228842E+09 0.00 0.35
February 0.237157E+09 458686.27 0.00 871948.33 167275.31 0.00 71792623.99 0.00 0.36
March 0.199697E+09 2330461.18 0.00 894030.22 2461235.92 0.00 69536739.43 0.00 0.36
April 31829055.23 44429529.68 0.00 1739383.42 3903441.40 0.00 84749613.84 0.00 0.35
May 21790009.30 78129625.47 0.00 1105936.32 7136785.70 0.00 48238001.46 0.00 0.35
June 7092526.97 0.168277E+09 0.00 815602.34 6735584.95 0.00 16588133.99 0.00 0.36
July 2809301.68 0.369744E+09 0.00 240354.63 18826616.79 0.00 7314145.90 0.00 0.36
August 2213650.12 0.332500E+09 0.00 369894.21 18205025.24 0.00 4574668.50 0.00 0.36
September 4526268.94 0.267529E+09 0.00 666014.63 17871415.93 0.00 6632776.04 0.00 0.36
October 45153900.35 61365604.15 0.00 4015953.72 3394691.04 0.00 0.125456E+09 0.00 0.36
November 52854563.34 6479157.85 0.00 4848701.94 2721437.79 0.00 0.217991E+09 0.00 0.36
December 0.146270E+09 243857.84 0.00 3768567.73 375114.57 0.00 0.256476E+09 0.00 0.35
                   
Annual Sum or Average 0.833827E+09 0.133174E+10 0.00 23313853.79 82216019.54 0.00 0.113819E+10 0.00 0.36
Minimum of Months 2213650.12 243857.84 0.00 240354.63 167275.31 0.00 4574668.50 0.00 0.35
Maximum of Months 0.237157E+09 0.369744E+09 0.00 4848701.94 18826616.79 0.00 0.256476E+09 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: G NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.234614E+09 867711.30 0.00 245020.08 1147139.99 12178184.02 24578450.98 0.00 0.35
February 0.259613E+09 221464.06 0.00 20218.40 678750.37 0.00 3817075.30 0.00 0.35
March 0.224521E+09 4127516.57 0.00 192926.42 1408438.44 0.00 15872186.95 0.00 0.35
April 34267738.21 55045941.65 0.00 1016504.61 1380560.04 0.00 78611086.27 0.00 0.35
May 19992463.27 93597179.33 0.00 857973.58 480781.56 0.00 48469434.02 0.00 0.35
June 6882748.47 0.186267E+09 0.00 731838.64 188272.08 0.00 16724767.12 0.00 0.36
July 2697860.05 0.417515E+09 0.00 212865.41 2973579.41 0.00 7021430.78 0.00 0.36
August 2223085.60 0.377670E+09 0.00 274269.38 6840041.76 0.00 4743986.33 0.00 0.36
September 3913429.21 0.294087E+09 0.00 452995.79 14408863.12 0.00 6388606.50 0.00 0.36
October 51617624.01 71122968.58 0.00 1747247.03 2364151.17 0.00 0.119179E+09 0.00 0.36
November 0.114629E+09 6364195.80 0.00 1339500.87 3852667.33 0.00 0.144463E+09 0.00 0.36
December 0.302079E+09 642997.71 0.00 278887.73 634711.34 0.00 57613458.44 0.00 0.35
                   
Annual Sum or Average 0.125705E+10 0.150753E+10 0.00 7370247.94 36357956.61 12178184.02 0.527483E+09 0.00 0.35
Minimum of Months 2223085.60 221464.06 0.00 20218.40 188272.08 0.00 3817075.30 0.00 0.35
Maximum of Months 0.302079E+09 0.417515E+09 0.00 1747247.03 14408863.12 12178184.02 0.144463E+09 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: OFFICE

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.998658E+09 315352.97 0.00 2224312.37 2273.09 0.00 0.177326E+09 0.00 0.50
February 0.926661E+09 0.00 0.00 781336.52 39955.95 0.00 0.199547E+09 0.00 0.50
March 0.891126E+09 2075152.45 0.00 980501.10 164089.87 47477.32 0.152379E+09 0.00 0.49
April 0.421324E+09 53675754.80 0.00 2260652.34 28187976.23 0.00 63644239.06 0.00 0.51
May 0.287055E+09 0.110007E+09 0.00 1788558.57 60074626.23 0.00 17199039.80 0.00 0.51
June 0.124455E+09 0.316325E+09 0.00 887186.81 0.137210E+09 0.00 1264269.87 0.00 0.51
July 0.111512E+09 0.419296E+09 0.00 458240.67 0.137071E+09 0.00 291438.98 0.00 0.52
August 0.143892E+09 0.455345E+09 0.00 815432.53 94348574.04 0.00 2166337.58 0.00 0.52
September 0.192995E+09 0.298346E+09 0.00 1327912.55 52866427.71 0.00 7416620.58 0.00 0.52
October 0.643158E+09 85467672.58 0.00 3521869.96 9969324.77 0.00 0.124157E+09 0.00 0.51
November 0.946210E+09 5138238.73 0.00 3181156.18 329152.40 0.00 0.166286E+09 0.00 0.50
December 0.123647E+10 149397.83 0.00 1689633.16 0.00 0.00 0.219491E+09 0.00 0.50
                   
Annual Sum or Average 0.692352E+10 0.174614E+10 0.00 19916792.76 0.520263E+09 47477.32 0.113117E+10 0.00 0.51
Minimum of Months 0.111512E+09 0.00 0.00 458240.67 0.00 0.00 291438.98 0.00 0.49
Maximum of Months 0.123647E+10 0.455345E+09 0.00 3521869.96 0.137210E+09 47477.32 0.219491E+09 0.00 0.52



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: G NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.232201E+09 874236.53 0.00 228520.27 1289248.61 12013621.93 26555105.93 0.00 0.35
February 0.263315E+09 221916.13 0.00 13197.27 651765.04 0.00 3672352.00 0.00 0.35
March 0.227196E+09 4117358.58 0.00 187891.12 1317398.80 0.00 16077170.84 0.00 0.35
April 35001840.47 54756582.58 0.00 1111577.42 603050.26 0.00 79873839.91 0.00 0.35
May 20556314.78 92234358.46 0.00 971990.22 147370.33 0.00 49676658.86 0.00 0.35
June 7019687.58 0.185393E+09 0.00 778294.43 147252.16 0.00 16923596.02 0.00 0.36
July 2780562.03 0.421589E+09 0.00 218165.66 2901396.18 0.00 7024095.03 0.00 0.36
August 2310856.57 0.382377E+09 0.00 268498.76 6782669.66 0.00 4746947.76 0.00 0.36
September 4104499.90 0.297143E+09 0.00 454497.97 14027482.97 0.00 6396834.34 0.00 0.36
October 52574415.34 71492838.49 0.00 1815186.10 2361923.12 0.00 0.119211E+09 0.00 0.36
November 0.110239E+09 6130473.72 0.00 1336471.96 3849001.62 0.00 0.148094E+09 0.00 0.35
December 0.300609E+09 645788.87 0.00 271649.08 606515.30 0.00 59672944.60 0.00 0.35
                   
Annual Sum or Average 0.125791E+10 0.151698E+10 0.00 7655940.26 34685074.04 12013621.93 0.537925E+09 0.00 0.35
Minimum of Months 2310856.57 221916.13 0.00 13197.27 147252.16 0.00 3672352.00 0.00 0.35
Maximum of Months 0.300609E+09 0.421589E+09 0.00 1815186.10 14027482.97 12013621.93 0.148094E+09 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: G N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.176569E+09 739571.21 0.00 526831.60 1147948.08 0.00 0.107328E+09 0.00 0.35
February 0.275501E+09 383560.48 0.00 47896.09 342995.05 0.00 15738790.17 0.00 0.36
March 0.209401E+09 3895340.22 0.00 351370.31 1037793.93 0.00 51990763.95 0.00 0.35
April 33130235.23 53614712.09 0.00 1086462.94 1041765.16 0.00 82300240.79 0.00 0.35
May 20792353.44 90560857.01 0.00 899559.22 408786.25 0.00 50224079.80 0.00 0.35
June 7311349.61 0.182387E+09 0.00 712913.03 134575.52 0.00 17748321.74 0.00 0.36
July 2761577.62 0.407059E+09 0.00 206181.68 3054812.10 0.00 7372261.13 0.00 0.36
August 2235579.83 0.368310E+09 0.00 234641.23 6700769.35 0.00 5070225.19 0.00 0.36
September 3943374.72 0.284787E+09 0.00 411889.04 13851573.56 0.00 7147314.41 0.00 0.36
October 50231962.61 69159317.76 0.00 1828986.79 2362102.06 0.00 0.120346E+09 0.00 0.36
November 73307164.56 6468876.07 0.00 1613629.97 3303756.61 0.00 0.186685E+09 0.00 0.36
December 0.239940E+09 601797.92 0.00 583231.24 511701.47 0.00 0.137083E+09 0.00 0.35
                   
Annual Sum or Average 0.109512E+10 0.146797E+10 0.00 8503593.13 33898579.14 0.00 0.789034E+09 0.00 0.35
Minimum of Months 2235579.83 383560.48 0.00 47896.09 134575.52 0.00 5070225.19 0.00 0.35
Maximum of Months 0.275501E+09 0.407059E+09 0.00 1828986.79 13851573.56 0.00 0.186685E+09 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: G N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.177264E+09 739513.97 0.00 527147.27 1153470.67 0.00 0.106534E+09 0.00 0.35
February 0.275700E+09 412485.81 0.00 49971.22 306899.22 0.00 16117606.44 0.00 0.36
March 0.209276E+09 3894406.13 0.00 355751.07 1024612.91 0.00 52555892.13 0.00 0.35
April 32963282.56 53629359.85 0.00 1090581.26 1008172.60 0.00 82526912.60 0.00 0.35
May 20815613.73 90533674.86 0.00 902836.35 405839.24 0.00 50226873.17 0.00 0.35
June 7289029.20 0.182371E+09 0.00 714138.34 134394.23 0.00 17773623.76 0.00 0.36
July 2760414.42 0.407263E+09 0.00 206128.28 3037155.69 0.00 7373838.02 0.00 0.36
August 2235821.23 0.368532E+09 0.00 234455.73 6700547.32 0.00 5071185.76 0.00 0.36
September 3948541.74 0.284919E+09 0.00 411911.42 13863931.64 0.00 7143169.60 0.00 0.36
October 50401300.09 69198479.71 0.00 1838580.37 2327050.92 0.00 0.120422E+09 0.00 0.36
November 73768849.01 6458244.51 0.00 1609788.90 3278768.82 0.00 0.186571E+09 0.00 0.36
December 0.239729E+09 601478.76 0.00 585006.00 508942.31 0.00 0.137484E+09 0.00 0.35
                   
Annual Sum or Average 0.109615E+10 0.146855E+10 0.00 8526296.20 33749785.58 0.00 0.789799E+09 0.00 0.35
Minimum of Months 2235821.23 412485.81 0.00 49971.22 134394.23 0.00 5071185.76 0.00 0.35
Maximum of Months 0.275700E+09 0.407263E+09 0.00 1838580.37 13863931.64 0.00 0.186571E+09 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: G S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 67715346.57 176002.36 0.00 5134348.48 396883.24 0.00 0.251440E+09 0.00 0.35
February 0.136577E+09 443794.11 0.00 1714774.30 100691.26 0.00 0.187103E+09 0.00 0.36
March 0.138070E+09 2272181.39 0.00 1564364.19 2057684.34 0.00 0.145939E+09 0.00 0.36
April 30895535.28 42142260.58 0.00 1915349.79 4369680.64 0.00 89403053.48 0.00 0.35
May 22926949.49 71109216.58 0.00 1176708.22 11390544.10 0.00 50097157.85 0.00 0.35
June 7443224.83 0.158735E+09 0.00 821971.04 12835444.28 0.00 17645696.72 0.00 0.36
July 2927432.29 0.351711E+09 0.00 224144.86 27681129.31 0.00 7629861.11 0.00 0.36
August 2105100.51 0.320049E+09 0.00 333582.95 23635730.76 0.00 4892227.61 0.00 0.36
September 4567396.68 0.259807E+09 0.00 617903.46 18167157.13 0.00 7364979.94 0.00 0.36
October 44341023.69 59692384.06 0.00 4258437.32 3299731.75 0.00 0.129513E+09 0.00 0.36
November 52278227.91 6886928.13 0.00 5384717.73 2675102.69 0.00 0.221551E+09 0.00 0.36
December 73781634.98 192287.00 0.00 5056637.56 351595.63 0.00 0.338424E+09 0.00 0.35
                   
Annual Sum or Average 0.583629E+09 0.127322E+10 0.00 28202939.90 0.106961E+09 0.00 0.145100E+10 0.00 0.36
Minimum of Months 2105100.51 176002.36 0.00 224144.86 100691.26 0.00 4892227.61 0.00 0.35
Maximum of Months 0.138070E+09 0.351711E+09 0.00 5384717.73 27681129.31 0.00 0.338424E+09 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: G S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 68549522.57 245522.35 0.00 5091842.65 434811.13 0.00 0.250406E+09 0.00 0.35
February 0.140952E+09 444464.13 0.00 1667857.63 98876.69 0.00 0.182668E+09 0.00 0.36
March 0.139079E+09 2258785.99 0.00 1576500.05 2026851.27 0.00 0.145075E+09 0.00 0.36
April 30909710.25 42861497.24 0.00 2040026.25 3454566.76 0.00 89831700.55 0.00 0.35
May 22919223.10 73330496.65 0.00 1302273.26 8649960.43 0.00 50560816.82 0.00 0.35
June 7572806.61 0.162456E+09 0.00 912255.09 8731915.72 0.00 17812375.32 0.00 0.36
July 2973044.20 0.362940E+09 0.00 254029.97 23896991.45 0.00 7670797.38 0.00 0.36
August 2243961.17 0.329499E+09 0.00 362276.14 20775743.22 0.00 4877458.55 0.00 0.36
September 4513368.25 0.266800E+09 0.00 662278.19 18711279.96 0.00 7256736.24 0.00 0.36
October 45055401.03 60643181.84 0.00 4442054.35 3387316.04 0.00 0.129463E+09 0.00 0.36
November 52701777.14 7027297.56 0.00 5411303.57 2707541.40 0.00 0.221370E+09 0.00 0.36
December 76838564.63 184020.24 0.00 4977645.89 352837.05 0.00 0.335332E+09 0.00 0.35
                   
Annual Sum or Average 0.594308E+09 0.130869E+10 0.00 28700343.06 93228691.13 0.00 0.144232E+10 0.00 0.36
Minimum of Months 2243961.17 184020.24 0.00 254029.97 98876.69 0.00 4877458.55 0.00 0.35
Maximum of Months 0.140952E+09 0.362940E+09 0.00 5411303.57 23896991.45 0.00 0.335332E+09 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: M SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.140341E+09 634324.38 0.00 10672284.23 889210.98 0.00 0.479190E+09 0.00 0.35
February 0.227035E+09 867779.88 0.00 5158020.83 58372.62 0.00 0.399537E+09 0.00 0.36
March 0.221371E+09 6359446.94 0.00 5859779.30 1607351.11 0.00 0.348932E+09 0.00 0.36
April 55769121.83 94790948.30 0.00 4672029.00 4790740.05 0.00 0.171843E+09 0.00 0.35
May 41129112.06 0.169450E+09 0.00 2807418.74 6298675.29 0.00 93461774.51 0.00 0.35
June 13340265.02 0.344882E+09 0.00 1689016.68 13592351.13 0.00 30622636.67 0.00 0.36
July 5251463.35 0.715398E+09 0.00 428235.38 53704128.18 0.00 13725798.74 0.00 0.36
August 4113451.15 0.633240E+09 0.00 668446.07 51657193.00 0.00 8533734.88 0.00 0.36
September 7476009.72 0.502093E+09 0.00 1012153.91 36874629.74 0.00 12557958.89 0.00 0.36
October 85391805.82 0.119413E+09 0.00 6783874.09 7870617.58 0.00 0.244648E+09 0.00 0.36
November 0.120975E+09 11131131.89 0.00 8968321.60 4659570.39 0.00 0.409723E+09 0.00 0.36
December 0.333475E+09 565303.31 0.00 7591911.75 785661.29 0.00 0.459527E+09 0.00 0.35
                   
Annual Sum or Average 0.125567E+10 0.259883E+10 0.00 56311491.58 0.182789E+09 0.00 0.267230E+10 0.00 0.36
Minimum of Months 4113451.15 565303.31 0.00 428235.38 58372.62 0.00 8533734.88 0.00 0.35
Maximum of Months 0.333475E+09 0.715398E+09 0.00 10672284.23 53704128.18 0.00 0.479190E+09 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: M NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.387698E+09 2135729.31 0.00 1432213.57 1590648.07 0.00 0.176275E+09 0.00 0.35
February 0.441189E+09 874578.81 0.00 850508.48 165844.18 0.00 0.156568E+09 0.00 0.36
March 0.316004E+09 9077643.11 0.00 2290434.07 1000427.26 0.00 0.232909E+09 0.00 0.36
April 57634950.27 0.114828E+09 0.00 2992913.86 1411602.21 0.00 0.166556E+09 0.00 0.35
May 39322112.49 0.193271E+09 0.00 2251916.05 679359.27 0.00 92925252.22 0.00 0.35
June 13127983.04 0.380899E+09 0.00 1520912.26 386531.14 0.00 30934318.08 0.00 0.36
July 5121221.14 0.826893E+09 0.00 378106.57 6093798.48 0.00 13252523.80 0.00 0.36
August 4211283.22 0.737861E+09 0.00 463841.19 12699099.08 0.00 8667847.01 0.00 0.36
September 7485574.19 0.559416E+09 0.00 721514.99 25686973.91 0.00 12483635.14 0.00 0.36
October 0.118278E+09 0.139000E+09 0.00 2353414.98 4907612.45 0.00 0.206231E+09 0.00 0.36
November 0.321542E+09 11477009.93 0.00 1719361.67 7535436.00 0.00 0.177857E+09 0.00 0.35
December 0.616154E+09 1404302.88 0.00 454468.99 1494562.37 0.00 79700667.17 0.00 0.35
                   
Annual Sum or Average 0.232777E+10 0.297714E+10 0.00 17429606.66 63651894.41 0.00 0.135436E+10 0.00 0.35
Minimum of Months 4211283.22 874578.81 0.00 378106.57 165844.18 0.00 8667847.01 0.00 0.35
Maximum of Months 0.616154E+09 0.826893E+09 0.00 2992913.86 25686973.91 0.00 0.232909E+09 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: M SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.134714E+09 592554.10 0.00 10863291.38 870887.21 0.00 0.491653E+09 0.00 0.35
February 0.209247E+09 847633.33 0.00 5484876.17 31919.66 0.00 0.421407E+09 0.00 0.36
March 0.217159E+09 6619122.39 0.00 6177004.40 921778.72 0.00 0.360707E+09 0.00 0.36
April 58325184.86 94272654.17 0.00 5197694.18 1331942.12 0.00 0.177705E+09 0.00 0.35
May 43416991.98 0.169719E+09 0.00 3188035.95 705225.97 0.00 97314266.22 0.00 0.35
June 13342348.16 0.351000E+09 0.00 1836433.95 4188731.50 0.00 31851688.08 0.00 0.36
July 5242136.41 0.751303E+09 0.00 453597.65 28534482.83 0.00 14023153.81 0.00 0.36
August 4323858.26 0.666235E+09 0.00 666092.07 30586823.13 0.00 8627565.96 0.00 0.36
September 7662734.05 0.518538E+09 0.00 1058403.40 29908796.29 0.00 12602640.28 0.00 0.36
October 81541790.54 0.122488E+09 0.00 7179567.10 5457626.43 0.00 0.253509E+09 0.00 0.36
November 0.117867E+09 10604047.74 0.00 9025902.40 4400313.43 0.00 0.418705E+09 0.00 0.36
December 0.326038E+09 471376.18 0.00 7807060.48 796657.80 0.00 0.472154E+09 0.00 0.35
                   
Annual Sum or Average 0.121888E+10 0.269269E+10 0.00 58937959.15 0.107735E+09 0.00 0.276026E+10 0.00 0.36
Minimum of Months 4323858.26 471376.18 0.00 453597.65 31919.66 0.00 8627565.96 0.00 0.35
Maximum of Months 0.326038E+09 0.751303E+09 0.00 10863291.38 30586823.13 0.00 0.491653E+09 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: M NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.380108E+09 2177462.66 0.00 1429520.17 1726654.64 1602612.79 0.177746E+09 0.00 0.35
February 0.398121E+09 875495.19 0.00 1007713.09 158533.19 0.00 0.198908E+09 0.00 0.36
March 0.302843E+09 8651197.20 0.00 2440005.72 916103.06 0.00 0.247032E+09 0.00 0.36
April 62495131.16 0.111727E+09 0.00 3377164.47 1010137.66 0.00 0.168721E+09 0.00 0.35
May 41468112.60 0.188788E+09 0.00 2550128.53 329557.31 0.00 95245122.77 0.00 0.35
June 13406600.04 0.378542E+09 0.00 1631764.57 355790.73 0.00 31526263.03 0.00 0.36
July 5176497.05 0.836099E+09 0.00 393699.44 5486265.35 0.00 13465357.78 0.00 0.36
August 4440324.98 0.749414E+09 0.00 448683.58 12004906.19 0.00 8736060.50 0.00 0.36
September 7778560.62 0.568593E+09 0.00 721901.90 24273274.54 0.00 12606289.69 0.00 0.36
October 0.116626E+09 0.141071E+09 0.00 2536409.98 4048127.10 0.00 0.208082E+09 0.00 0.36
November 0.315957E+09 10379922.21 0.00 1693127.95 5115855.46 0.00 0.187591E+09 0.00 0.35
December 0.609322E+09 1388040.58 0.00 438481.32 1435419.83 0.00 89083643.92 0.00 0.35
                   
Annual Sum or Average 0.225774E+10 0.299771E+10 0.00 18668600.73 56860625.06 1602612.79 0.143874E+10 0.00 0.35
Minimum of Months 4440324.98 875495.19 0.00 393699.44 158533.19 0.00 8736060.50 0.00 0.35
Maximum of Months 0.609322E+09 0.836099E+09 0.00 3377164.47 24273274.54 1602612.79 0.247032E+09 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: M N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.212458E+09 1867720.71 0.00 2556387.49 1569448.07 0.00 0.366327E+09 0.00 0.35
February 0.238512E+09 896661.82 0.00 1931448.37 142003.47 0.00 0.360288E+09 0.00 0.36
March 0.185760E+09 8578566.26 0.00 3167202.44 1005476.81 0.00 0.372029E+09 0.00 0.36
April 57964537.77 0.110553E+09 0.00 2899038.42 1437919.24 0.00 0.170009E+09 0.00 0.35
May 40712420.52 0.185752E+09 0.00 2143582.25 680492.53 0.00 97496913.29 0.00 0.35
June 14258862.98 0.371011E+09 0.00 1422278.27 401976.72 0.00 33305319.38 0.00 0.36
July 5407543.59 0.804274E+09 0.00 354053.37 6002231.45 0.00 14012687.32 0.00 0.36
August 4307490.72 0.719699E+09 0.00 413047.32 12565317.93 0.00 9540801.90 0.00 0.36
September 7631400.10 0.543359E+09 0.00 685021.44 25948044.53 0.00 14138116.89 0.00 0.36
October 87850356.20 0.135251E+09 0.00 2832703.16 4976569.09 0.00 0.229559E+09 0.00 0.36
November 0.185092E+09 11726967.62 0.00 2602855.90 5267496.83 0.00 0.326707E+09 0.00 0.35
December 0.485008E+09 1326063.75 0.00 1229755.66 1011450.14 0.00 0.260479E+09 0.00 0.35
                   
Annual Sum or Average 0.152496E+10 0.289429E+10 0.00 22237374.08 61008426.82 0.00 0.225389E+10 0.00 0.36
Minimum of Months 4307490.72 896661.82 0.00 354053.37 142003.47 0.00 9540801.90 0.00 0.35
Maximum of Months 0.485008E+09 0.804274E+09 0.00 3167202.44 25948044.53 0.00 0.372029E+09 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: M N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.213336E+09 1866912.54 0.00 2544601.14 1573328.96 0.00 0.365373E+09 0.00 0.35
February 0.237298E+09 896421.65 0.00 1952625.62 139919.15 0.00 0.361246E+09 0.00 0.36
March 0.184342E+09 8576084.14 0.00 3186595.40 998226.82 0.00 0.373674E+09 0.00 0.36
April 58099343.85 0.110523E+09 0.00 2908605.53 1433177.93 0.00 0.170045E+09 0.00 0.35
May 40765578.43 0.185680E+09 0.00 2149902.00 677195.60 0.00 97516699.26 0.00 0.35
June 14244068.00 0.370968E+09 0.00 1423059.33 400993.37 0.00 33329163.37 0.00 0.36
July 5408877.91 0.804626E+09 0.00 353786.64 5995103.80 0.00 14013579.86 0.00 0.36
August 4308617.07 0.720190E+09 0.00 412447.82 12525019.30 0.00 9541267.86 0.00 0.36
September 7635456.67 0.543669E+09 0.00 684664.72 25988136.17 0.00 14137204.03 0.00 0.36
October 87845642.12 0.135323E+09 0.00 2841478.95 4965154.63 0.00 0.229607E+09 0.00 0.36
November 0.186354E+09 11638957.71 0.00 2591058.80 5261776.70 0.00 0.325748E+09 0.00 0.35
December 0.485398E+09 1325163.66 0.00 1235681.53 1002958.43 0.00 0.260606E+09 0.00 0.35
                   
Annual Sum or Average 0.152504E+10 0.289528E+10 0.00 22284507.49 60960990.87 0.00 0.225484E+10 0.00 0.36
Minimum of Months 4308617.07 896421.65 0.00 353786.64 139919.15 0.00 9541267.86 0.00 0.35
Maximum of Months 0.485398E+09 0.804626E+09 0.00 3186595.40 25988136.17 0.00 0.373674E+09 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: M S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.121348E+09 561548.88 0.00 12671960.87 844642.47 0.00 0.512659E+09 0.00 0.35
February 0.132150E+09 858486.68 0.00 7055610.35 35795.33 0.00 0.485176E+09 0.00 0.36
March 0.157495E+09 6068956.19 0.00 7152942.85 1555797.03 0.00 0.422034E+09 0.00 0.36
April 57947662.15 89814533.41 0.00 4641058.59 5799116.51 0.00 0.177332E+09 0.00 0.35
May 43363659.54 0.157341E+09 0.00 2719404.97 12099444.55 0.00 97760637.84 0.00 0.35
June 14174228.01 0.321308E+09 0.00 1622825.26 28784966.99 0.00 33039390.05 0.00 0.36
July 5520792.11 0.676198E+09 0.00 397902.07 72549742.50 0.00 14546626.71 0.00 0.36
August 4171225.50 0.602777E+09 0.00 610151.78 68360401.01 0.00 9374594.26 0.00 0.36
September 7563022.00 0.486111E+09 0.00 967885.08 41434277.97 0.00 14266003.26 0.00 0.36
October 83603542.93 0.115881E+09 0.00 7617284.80 8442769.75 0.00 0.254395E+09 0.00 0.36
November 98831362.21 12573790.38 0.00 10505091.40 4736525.16 0.00 0.439454E+09 0.00 0.36
December 0.161353E+09 448558.55 0.00 10530495.25 727653.53 0.00 0.656978E+09 0.00 0.35
                   
Annual Sum or Average 0.887522E+09 0.246994E+10 0.00 66492613.28 0.245371E+09 0.00 0.311702E+10 0.00 0.36
Minimum of Months 4171225.50 448558.55 0.00 397902.07 35795.33 0.00 9374594.26 0.00 0.35
Maximum of Months 0.161353E+09 0.676198E+09 0.00 12671960.87 72549742.50 0.00 0.656978E+09 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: M S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.121266E+09 560237.92 0.00 12690261.12 841831.06 0.00 0.512831E+09 0.00 0.35
February 0.131191E+09 858378.76 0.00 7089642.53 35151.93 0.00 0.486095E+09 0.00 0.36
March 0.157525E+09 6124252.77 0.00 7200347.04 1492084.89 0.00 0.422935E+09 0.00 0.36
April 57617283.70 90023106.73 0.00 4668370.17 5443085.48 0.00 0.177882E+09 0.00 0.35
May 43362804.96 0.157817E+09 0.00 2736625.38 11364227.06 0.00 97946987.51 0.00 0.35
June 14189386.55 0.322351E+09 0.00 1626841.93 27627456.95 0.00 33038845.27 0.00 0.36
July 5525000.17 0.678453E+09 0.00 398077.83 70778078.15 0.00 14547311.31 0.00 0.36
August 4158102.21 0.604410E+09 0.00 610464.51 67290248.53 0.00 9391119.94 0.00 0.36
September 7575548.10 0.486825E+09 0.00 969416.48 41185046.31 0.00 14254576.67 0.00 0.36
October 83010997.35 0.116180E+09 0.00 7647342.96 8198676.10 0.00 0.255138E+09 0.00 0.36
November 98495889.11 12539037.95 0.00 10513166.29 4728850.43 0.00 0.440052E+09 0.00 0.36
December 0.159624E+09 448114.37 0.00 10561321.41 728523.57 0.00 0.658827E+09 0.00 0.35
                   
Annual Sum or Average 0.883541E+09 0.247659E+10 0.00 66711877.67 0.239713E+09 0.00 0.312294E+10 0.00 0.36
Minimum of Months 4158102.21 448114.37 0.00 398077.83 35151.93 0.00 9391119.94 0.00 0.35
Maximum of Months 0.159624E+09 0.678453E+09 0.00 12690261.12 70778078.15 0.00 0.658827E+09 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: T SW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.197530E+09 428229.39 0.00 3284878.38 371826.25 11815583.18 66451792.51 0.00 0.35
February 0.209157E+09 104354.72 0.00 1351963.78 429129.91 22176592.90 48317309.67 0.00 0.36
March 0.185185E+09 3664537.76 0.00 1645086.45 732944.95 23406863.87 44301966.68 0.00 0.35
April 51912952.53 49978031.89 0.00 1471874.03 1812013.43 0.00 55328394.09 0.00 0.35
May 23364217.42 88596370.27 0.00 811330.49 1510550.80 0.00 39336511.32 0.00 0.35
June 5672040.15 0.178096E+09 0.00 572991.70 3168294.85 0.00 14583774.28 0.00 0.36
July 2211301.29 0.368511E+09 0.00 145252.33 12027380.30 0.00 6591508.66 0.00 0.36
August 2090135.19 0.319693E+09 0.00 234775.51 14727946.91 0.00 4049404.48 0.00 0.36
September 3763326.07 0.249564E+09 0.00 406178.71 12932467.76 0.00 6708929.54 0.00 0.36
October 99143397.09 59706165.44 0.00 2176247.17 2954349.25 0.00 54046290.84 0.00 0.36
November 0.169723E+09 3619556.29 0.00 2821756.09 2119081.88 8616297.22 72389611.26 0.00 0.35
December 0.206757E+09 420638.91 0.00 2039105.90 764197.23 77609415.11 56579246.75 0.00 0.35
                   
Annual Sum or Average 0.115651E+10 0.132238E+10 0.00 16961440.54 53550183.53 0.143625E+09 0.468685E+09 0.00 0.36
Minimum of Months 2090135.19 104354.72 0.00 145252.33 371826.25 0.00 4049404.48 0.00 0.35
Maximum of Months 0.209157E+09 0.368511E+09 0.00 3284878.38 14727946.91 77609415.11 72389611.26 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: T NW APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.166233E+09 1424936.63 0.00 136232.35 1089630.58 61211797.51 5062654.52 0.00 0.35
February 0.165354E+09 27129.46 0.00 43288.75 741972.59 72660773.19 3788696.12 0.00 0.35
March 0.175325E+09 4839373.45 0.00 498311.40 940955.54 40442465.03 19590141.94 0.00 0.35
April 60907909.50 59373677.88 0.00 889167.19 1064008.84 0.00 44964379.43 0.00 0.35
May 24471144.75 99858444.44 0.00 695885.03 454395.70 0.00 37716438.70 0.00 0.35
June 5794880.45 0.193749E+09 0.00 560694.14 242851.77 0.00 14632837.47 0.00 0.36
July 2289690.52 0.413053E+09 0.00 129817.36 2434451.42 0.00 6354471.07 0.00 0.36
August 2184113.10 0.365587E+09 0.00 184011.88 5395522.45 0.00 4184695.81 0.00 0.36
September 3952620.26 0.276928E+09 0.00 275537.05 10664149.21 0.00 6597915.49 0.00 0.36
October 0.112165E+09 69147108.81 0.00 518074.78 3036247.88 3578071.83 26512085.23 0.00 0.35
November 0.158874E+09 4321658.65 0.00 219750.77 4051851.59 47286386.42 12074561.71 0.00 0.35
December 0.126950E+09 859335.59 0.00 13434.35 1949827.47 0.165935E+09 347420.09 0.00 0.35
                   
Annual Sum or Average 0.100450E+10 0.148917E+10 0.00 4164205.06 32065865.04 0.391115E+09 0.181826E+09 0.00 0.35
Minimum of Months 2184113.10 27129.46 0.00 13434.35 242851.77 0.00 347420.09 0.00 0.35
Maximum of Months 0.175325E+09 0.413053E+09 0.00 889167.19 10664149.21 0.165935E+09 44964379.43 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: T SE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.198464E+09 317148.03 0.00 3307108.53 365430.54 11660024.04 70780932.91 0.00 0.35
February 0.209120E+09 103579.27 0.00 1343826.82 415491.15 19906786.32 57103658.10 0.00 0.36
March 0.188674E+09 3644199.48 0.00 1662478.89 417611.95 21471787.99 47074395.87 0.00 0.35
April 54109045.71 49396905.64 0.00 1789370.71 606092.90 0.00 57670237.71 0.00 0.35
May 25185260.92 87396456.75 0.00 1066569.26 327943.50 0.00 40619492.71 0.00 0.35
June 5628195.47 0.177969E+09 0.00 658630.14 1562222.23 0.00 15158055.19 0.00 0.36
July 2241495.12 0.377633E+09 0.00 158407.70 8083916.85 0.00 6724616.09 0.00 0.36
August 2262343.17 0.328837E+09 0.00 230647.45 11213194.42 0.00 4074265.62 0.00 0.36
September 3868921.55 0.255477E+09 0.00 425840.13 11534758.58 0.00 6732410.75 0.00 0.36
October 98638515.50 60878270.64 0.00 2276355.98 2052373.96 0.00 57345640.47 0.00 0.36
November 0.170066E+09 3548876.98 0.00 2718938.58 2026952.75 8073754.08 75828151.24 0.00 0.35
December 0.214618E+09 380524.50 0.00 1989228.79 787898.44 73508682.82 56662181.26 0.00 0.35
                   
Annual Sum or Average 0.117288E+10 0.134558E+10 0.00 17627402.99 39393887.27 0.134621E+09 0.495774E+09 0.00 0.36
Minimum of Months 2241495.12 103579.27 0.00 158407.70 327943.50 0.00 4074265.62 0.00 0.35
Maximum of Months 0.214618E+09 0.377633E+09 0.00 3307108.53 11534758.58 73508682.82 75828151.24 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: T NE APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.168633E+09 1442063.90 0.00 94348.27 1092614.44 59367567.01 2570995.99 0.00 0.35
February 0.177434E+09 15535.60 0.00 18387.30 773400.77 63880014.08 2416539.73 0.00 0.35
March 0.180680E+09 4825048.34 0.00 449360.73 657420.28 37370642.47 18764590.74 0.00 0.35
April 65410688.85 58275362.51 0.00 1088859.54 538267.51 0.00 44391814.07 0.00 0.35
May 27170200.00 97849501.21 0.00 914006.67 183516.06 0.00 37665437.86 0.00 0.35
June 5955866.31 0.192538E+09 0.00 630387.67 182211.81 0.00 14941507.94 0.00 0.36
July 2322426.81 0.417708E+09 0.00 137378.67 2084021.06 0.00 6490469.28 0.00 0.36
August 2393757.60 0.371642E+09 0.00 181141.87 5072698.89 0.00 4201753.89 0.00 0.36
September 4243941.15 0.281833E+09 0.00 279153.76 10016939.72 0.00 6661358.90 0.00 0.36
October 0.115964E+09 70707219.53 0.00 498695.93 1830109.65 2787139.24 27163122.24 0.00 0.35
November 0.166704E+09 4218203.99 0.00 168000.96 3112882.84 42096657.58 9055201.78 0.00 0.35
December 0.130692E+09 824005.12 0.00 6996.90 1497344.39 0.160533E+09 28847.99 0.00 0.35
                   
Annual Sum or Average 0.104760E+10 0.150188E+10 0.00 4466718.26 27041427.40 0.366035E+09 0.174352E+09 0.00 0.35
Minimum of Months 2322426.81 15535.60 0.00 6996.90 182211.81 0.00 28847.99 0.00 0.35
Maximum of Months 0.180680E+09 0.417708E+09 0.00 1088859.54 10016939.72 0.160533E+09 44391814.07 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: T N1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.209853E+09 1195640.69 0.00 120546.50 1202060.98 24284055.10 8791326.78 0.00 0.35
February 0.219588E+09 71923.05 0.00 30977.22 669725.80 30503435.19 4371729.80 0.00 0.35
March 0.198977E+09 4579839.04 0.00 474145.27 864632.86 16011596.08 30811833.05 0.00 0.35
April 50850129.51 56809832.41 0.00 905606.37 807297.04 0.00 59600319.11 0.00 0.35
May 21946305.89 95157686.66 0.00 740072.01 417659.26 0.00 44428916.15 0.00 0.35
June 6221115.78 0.187809E+09 0.00 579466.39 209056.21 0.00 16344422.14 0.00 0.36
July 2452507.12 0.406521E+09 0.00 133908.42 2459169.10 0.00 6851525.63 0.00 0.36
August 2229382.40 0.361125E+09 0.00 173654.68 5500581.04 0.00 4615673.89 0.00 0.36
September 4019196.06 0.272606E+09 0.00 281141.66 11035395.13 0.00 7356336.88 0.00 0.36
October 0.108101E+09 67691376.20 0.00 569457.71 2774467.91 0.00 40341092.60 0.00 0.35
November 0.191526E+09 4516374.83 0.00 228563.58 3127692.73 14044337.55 19131967.50 0.00 0.35
December 0.178998E+09 760995.25 0.00 12012.12 1669121.74 0.120247E+09 1768374.47 0.00 0.35
                   
Annual Sum or Average 0.119476E+10 0.145885E+10 0.00 4249551.93 30736859.81 0.205090E+09 0.244414E+09 0.00 0.35
Minimum of Months 2229382.40 71923.05 0.00 12012.12 209056.21 0.00 1768374.47 0.00 0.35
Maximum of Months 0.219588E+09 0.406521E+09 0.00 905606.37 11035395.13 0.120247E+09 59600319.11 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: T N2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.209666E+09 1199670.90 0.00 119360.29 1185125.07 24547531.95 8536287.21 0.00 0.35
February 0.220652E+09 72540.23 0.00 31424.34 665718.63 29797606.12 4414918.14 0.00 0.35
March 0.198946E+09 4580553.68 0.00 474235.60 833884.84 15973645.90 31042836.62 0.00 0.35
April 50992407.88 56765585.54 0.00 913770.43 793717.95 0.00 59663577.10 0.00 0.35
May 21958269.83 95074912.56 0.00 747759.50 403787.80 0.00 44507980.14 0.00 0.35
June 6190291.90 0.187768E+09 0.00 579768.75 206870.88 0.00 16382869.67 0.00 0.36
July 2449257.36 0.406711E+09 0.00 133846.77 2434344.97 0.00 6857959.92 0.00 0.36
August 2234346.60 0.361376E+09 0.00 173159.20 5497287.18 0.00 4615729.52 0.00 0.36
September 4025951.32 0.272849E+09 0.00 280985.58 11006604.20 0.00 7359600.78 0.00 0.36
October 0.109325E+09 67847276.43 0.00 576153.61 2633214.72 0.00 41219033.37 0.00 0.35
November 0.192086E+09 4393798.02 0.00 230986.71 2630008.40 14382202.06 19181415.89 0.00 0.35
December 0.179199E+09 734242.44 0.00 11069.97 1654967.18 0.120226E+09 1495199.24 0.00 0.35
                   
Annual Sum or Average 0.119772E+10 0.145937E+10 0.00 4272520.76 29945531.83 0.204927E+09 0.245277E+09 0.00 0.35
Minimum of Months 2234346.60 72540.23 0.00 11069.97 206870.88 0.00 1495199.24 0.00 0.35
Maximum of Months 0.220652E+09 0.406711E+09 0.00 913770.43 11006604.20 0.120226E+09 59663577.10 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: T S1 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.192304E+09 270350.00 0.00 3742963.47 359691.92 6125146.16 98934449.53 0.00 0.35
February 0.225496E+09 406950.33 0.00 1531388.11 90784.82 4086996.63 72447120.04 0.00 0.36
March 0.190885E+09 3520695.72 0.00 1723516.01 670986.69 6343501.01 70928639.68 0.00 0.36
April 36841979.23 47644645.88 0.00 1514092.24 1632180.17 0.00 76490952.42 0.00 0.35
May 21837597.98 84654871.47 0.00 869389.91 1380069.59 0.00 45096247.32 0.00 0.35
June 6180212.00 0.172552E+09 0.00 593889.66 3349265.09 0.00 16111932.89 0.00 0.36
July 2400500.44 0.361146E+09 0.00 145065.69 13559304.36 0.00 7115806.20 0.00 0.36
August 2130919.81 0.315586E+09 0.00 223835.88 16016819.11 0.00 4509544.62 0.00 0.36
September 3815571.86 0.246761E+09 0.00 394248.26 13558692.80 0.00 7545260.68 0.00 0.36
October 82974182.55 58551074.07 0.00 2427249.41 2949880.23 0.00 79305986.01 0.00 0.36
November 0.158800E+09 3569107.68 0.00 3130039.16 2079868.23 2545787.90 0.101781E+09 0.00 0.36
December 0.246313E+09 350098.60 0.00 2404741.71 670654.65 32403578.63 84887692.06 0.00 0.35
                   
Annual Sum or Average 0.116998E+10 0.129501E+10 0.00 18700419.50 56318197.65 51505010.34 0.665154E+09 0.00 0.36
Minimum of Months 2130919.81 270350.00 0.00 145065.69 90784.82 0.00 4509544.62 0.00 0.35
Maximum of Months 0.246313E+09 0.361146E+09 0.00 3742963.47 16016819.11 32403578.63 0.101781E+09 0.00 0.36



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: T S2 APARTMENT

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.192034E+09 259881.39 0.00 3771701.78 358779.48 6124357.24 99509875.02 0.00 0.35
February 0.224917E+09 406607.79 0.00 1554909.81 89240.78 4085250.43 73736070.14 0.00 0.36
March 0.190993E+09 3536720.63 0.00 1745605.47 641458.90 6343683.26 71241299.37 0.00 0.36
April 37173921.90 47700488.85 0.00 1536192.02 1467148.05 0.00 76363015.08 0.00 0.35
May 21866671.06 84681603.24 0.00 878232.69 1235735.97 0.00 45174746.84 0.00 0.35
June 6150726.42 0.172585E+09 0.00 595508.89 3234466.81 0.00 16152096.84 0.00 0.36
July 2402403.31 0.361656E+09 0.00 145262.60 13291722.99 0.00 7116772.06 0.00 0.36
August 2130621.68 0.316036E+09 0.00 223651.05 15841378.02 0.00 4513239.80 0.00 0.36
September 3811923.41 0.247081E+09 0.00 395104.51 13462333.32 0.00 7553244.11 0.00 0.36
October 82966870.18 58666050.03 0.00 2447254.64 2835523.55 0.00 79516016.23 0.00 0.36
November 0.159112E+09 3561335.11 0.00 3137704.33 2077808.00 2545456.55 0.101832E+09 0.00 0.36
December 0.246141E+09 349708.59 0.00 2423696.68 675163.59 32168747.86 85577282.26 0.00 0.35
                   
Annual Sum or Average 0.116970E+10 0.129652E+10 0.00 18854824.46 55210759.46 51267495.34 0.668286E+09 0.00 0.36
Minimum of Months 2130621.68 259881.39 0.00 145262.60 89240.78 0.00 4513239.80 0.00 0.35
Maximum of Months 0.246141E+09 0.361656E+09 0.00 3771701.78 15841378.02 32168747.86 0.101832E+09 0.00 0.36



Table of Contents

Report: HeatEmissionsReportMonthly

For: Environment

Timestamp: 2024-07-03 12:27:39

Custom Monthly Report

SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J]
January 0.106391E+12 0.740952E+10 0.00 0.117745E+10 0.318550E+11
February 0.105543E+12 0.688072E+10 0.00 0.112695E+10 0.141492E+11
March 0.125818E+12 0.836968E+10 0.00 0.104229E+10 0.243214E+11
April 0.137131E+12 0.324699E+10 0.00 0.405365E+09 0.872861E+11
May 0.124725E+12 0.148265E+10 0.00 0.135961E+09 0.109486E+12
June 0.128272E+12 -0.130401E+10 0.00 -326928374.4 0.149940E+12
July 0.124991E+12 -0.222944E+10 0.00 -444105451.0 0.162588E+12
August 0.113036E+12 -0.156909E+10 0.00 -402819827.3 0.155596E+12
September 0.104106E+12 -635381650.6 0.00 -149472636.4 0.138716E+12
October 0.107505E+12 0.490316E+10 0.00 0.675399E+09 0.792778E+11
November 0.104803E+12 0.770079E+10 0.00 0.111021E+10 0.382797E+11
December 0.882398E+11 0.699708E+10 0.00 0.145750E+10 0.204047E+11
           
Annual Sum or Average 0.137056E+13 0.412527E+11 0.00 0.580781E+10 0.101190E+13
Minimum of Months 0.882398E+11 -0.222944E+10 0.00 -444105451.0 0.141492E+11
Maximum of Months 0.137131E+12 0.836968E+10 0.00 0.145750E+10 0.162588E+12