Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2024.07.03 12:20
Tabular Output Report in Format: HTML
Building: OfficeMedium
Environment: RUNPERIOD 1 ** Great Falls Intl Arpt MT USA TMY3 WMO#=727750
Simulation Timestamp: 2024-07-03 12:20:12
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1964.16 | 394.24 | 394.24 |
Net Site Energy | 1964.16 | 394.24 | 394.24 |
Total Source Energy | 4995.38 | 1002.65 | 1002.65 |
Net Source Energy | 4995.38 | 1002.65 | 1002.65 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 1.200 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil No 1 | 1.050 |
Fuel Oil No 2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4982.19 |
Net Conditioned Building Area | 4982.19 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 588.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 106.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 301.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 51.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 719.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 26.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 107.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 2.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 59.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1376.01 | 588.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler | 0.00 | 588.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 106.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 301.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 51.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | ElevatorLift | 134.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLightsFan | 0.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
MiscPlug | 584.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 26.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 107.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 2.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 | |
Water Heater | 59.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Unassigned | 0.00 | 588.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | Unassigned | 106.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GENERAL | 301.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | Unassigned | 51.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | GENERAL | 719.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | Unassigned | 26.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Unassigned | 107.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | Unassigned | 2.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Unassigned | 59.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 70.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 55.36 | 118.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Other | 149.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 276.19 | 118.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 70.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 55.36 | 118.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Other | 149.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 276.19 | 118.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1376.008 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1376.008 | 100.00 |
Total On-Site and Utility Electric Sources | 1376.008 | 100.00 |
Total Electricity End Uses | 1376.008 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 271.06 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 271.06 | 100.00 |
Total Water End Uses | 271.06 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 438.50 |
Time Setpoint Not Met During Occupied Cooling | 104.50 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 2745.50 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 6B
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2016
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICEMEDIUM
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MT_GREATFALLS
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PERFORMANCEPATHPROPOSED
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |ZoneCoolingSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ZoneHeatingSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ZoneElectricSummaryMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |SpaceGainsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | FIRSTFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM |PeakSpaceGainsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | FIRSTFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM |SpaceGainComponentsAtCoolingPeakMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ComfortReportSimple55Monthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |OccupantComfortDataSummaryMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |BoilerReportMonthly
| HEATSYS1 BOILER |DXReportMonthly
| PACU_VAV_BOT COOLING COIL | PACU_VAV_MID COOLING COIL | PACU_VAV_TOP COOLING COIL |WindowReportMonthly
| PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW |WindowEnergyReportMonthly
| PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW |WindowZoneSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |WindowEnergyZoneSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWHSYS1 WATER HEATER |DaylightingReportMonthly
| PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_4_DAYLCTRL |CoilReportMonthly
| PACU_VAV_BOT HEATING COIL | CORE_BOTTOM VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | PACU_VAV_MID HEATING COIL | CORE_MID VAV BOX REHEAT COIL | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | PACU_VAV_TOP HEATING COIL | CORE_TOP VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | PACU_VAV_BOT COOLING COIL | PACU_VAV_MID COOLING COIL | PACU_VAV_TOP COOLING COIL |PlantLoopDemandReportMonthly
| HEATSYS1 | SWHSYS1 |FanReportMonthly
| PACU_VAV_BOT FAN | PACU_VAV_MID FAN | PACU_VAV_TOP FAN |PumpReportMonthly
| HEATSYS1 PUMP | SWHSYS1 PUMP |CondLoopDemandReportMonthly
| HEATSYS1 | SWHSYS1 |ZoneTemperatureOscillationReportMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |AirLoopSystemEnergyAndWaterUseMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |AirLoopSystemComponentLoadsMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |AirLoopSystemComponentEnergyUseMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |MechanicalVentilationLoadsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
GeneralValue | |
Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2024.07.03 12:20 |
RunPeriod | RUNPERIOD 1 |
Weather File | Great Falls Intl Arpt MT USA TMY3 WMO#=727750 |
Latitude [deg] | 47.47 |
Longitude [deg] | -111.4 |
Elevation [m] | 1117.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Above Ground Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Window Opening Area [m2] | 652.62 | 195.79 | 130.53 | 195.79 | 130.53 |
Gross Window-Wall Ratio [%] | 33.00 | 33.00 | 33.00 | 33.00 | 33.00 |
Above Ground Window-Wall Ratio [%] | 33.00 | 33.00 | 33.00 | 33.00 | 33.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Above Ground Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Window Opening Area [m2] | 652.62 | 195.79 | 130.53 | 195.79 | 130.53 |
Gross Window-Wall Ratio [%] | 33.00 | 33.00 | 33.00 | 33.00 | 33.00 |
Above Ground Window-Wall Ratio [%] | 33.00 | 33.00 | 33.00 | 33.00 | 33.00 |
Total | |
Gross Roof Area [m2] | 1660.73 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
CORE_BOTTOM | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.6994 | 18.58 | 89.4590 |
TOPFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
MIDFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
FIRSTFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
CORE_MID | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.6994 | 18.58 | 8.0700 |
CORE_TOP | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.6994 | 18.58 | 8.0700 |
PERIMETER_TOP_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 8.6994 | 18.58 | 8.0700 |
PERIMETER_TOP_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 8.6994 | 18.58 | 8.0695 |
PERIMETER_TOP_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 8.6994 | 18.58 | 8.0699 |
PERIMETER_TOP_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 8.6994 | 18.58 | 8.0700 |
PERIMETER_BOT_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 8.6994 | 18.58 | 8.0700 |
PERIMETER_BOT_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 8.6994 | 18.58 | 8.0695 |
PERIMETER_BOT_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 8.6994 | 18.58 | 8.0699 |
PERIMETER_BOT_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 8.6994 | 18.58 | 8.0700 |
PERIMETER_MID_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 8.6994 | 18.58 | 8.0700 |
PERIMETER_MID_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 8.6994 | 18.58 | 8.0695 |
PERIMETER_MID_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 8.6994 | 18.58 | 8.0699 |
PERIMETER_MID_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 8.6994 | 18.58 | 8.0700 |
Total | 4982.19 | 13667.13 | 1369.16 | 0.00 | 652.62 | 652.62 | 8.6994 | 18.58 | 24.1370 | |||
Conditioned Total | 4982.19 | 13667.13 | 1369.16 | 0.00 | 652.62 | 652.62 | 8.6994 | 18.58 | 24.1370 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 4982.19 | 6074.28 | 608.51 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
CORE_BOTTOM | 983.54 | Yes | Yes | 1.00 | CORE_BOTTOM | GENERAL | CORE_BOTTOM | 8.6994 | 18.58 | 89.4590 | |
TOPFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | TOPFLOOR_PLENUM | GENERAL | TOPFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
MIDFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | MIDFLOOR_PLENUM | GENERAL | MIDFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
FIRSTFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | FIRSTFLOOR_PLENUM | GENERAL | FIRSTFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
CORE_MID | 983.54 | Yes | Yes | 1.00 | CORE_MID | GENERAL | CORE_MID | 8.6994 | 18.58 | 8.0700 | |
CORE_TOP | 983.54 | Yes | Yes | 1.00 | CORE_TOP | GENERAL | CORE_TOP | 8.6994 | 18.58 | 8.0700 | |
PERIMETER_TOP_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_3 | GENERAL | PERIMETER_TOP_ZN_3 | 8.6994 | 18.58 | 8.0700 | |
PERIMETER_TOP_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_2 | GENERAL | PERIMETER_TOP_ZN_2 | 8.6994 | 18.58 | 8.0695 | |
PERIMETER_TOP_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_1 | GENERAL | PERIMETER_TOP_ZN_1 | 8.6994 | 18.58 | 8.0699 | |
PERIMETER_TOP_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_4 | GENERAL | PERIMETER_TOP_ZN_4 | 8.6994 | 18.58 | 8.0700 | |
PERIMETER_BOT_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_3 | GENERAL | PERIMETER_BOT_ZN_3 | 8.6994 | 18.58 | 8.0700 | |
PERIMETER_BOT_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_2 | GENERAL | PERIMETER_BOT_ZN_2 | 8.6994 | 18.58 | 8.0695 | |
PERIMETER_BOT_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_1 | GENERAL | PERIMETER_BOT_ZN_1 | 8.6994 | 18.58 | 8.0699 | |
PERIMETER_BOT_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_4 | GENERAL | PERIMETER_BOT_ZN_4 | 8.6994 | 18.58 | 8.0700 | |
PERIMETER_MID_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_3 | GENERAL | PERIMETER_MID_ZN_3 | 8.6994 | 18.58 | 8.0700 | |
PERIMETER_MID_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_2 | GENERAL | PERIMETER_MID_ZN_2 | 8.6994 | 18.58 | 8.0695 | |
PERIMETER_MID_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_1 | GENERAL | PERIMETER_MID_ZN_1 | 8.6994 | 18.58 | 8.0699 | |
PERIMETER_MID_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_4 | GENERAL | PERIMETER_MID_ZN_4 | 8.6994 | 18.58 | 8.0700 | |
Total | 4982.19 | 8.6994 | 9.29 | 24.1370 | |||||||
Conditioned Total | 4982.19 | 8.6994 | 9.29 | 24.1370 | |||||||
Unconditioned Total | 0.00 | 0.0000 | 0.00 | 0.0000 | |||||||
Not Part of Total | 4982.19 | 0.0000 | 0.00 | 0.0000 |
Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
GENERAL | 4982.19 | 4982.19 | 0.00 | 4982.19 | 8.6994 | 18.58 | 24.1370 |
Total | 4982.19 | 4982.19 | 0.00 | 4982.19 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
End UsesElectricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 17-JUL-15:30 | 09-JAN-07:19 | - | - | - | - | - | - | - | - | - | - | 05-JAN-12:09 |
Heating | 0.00 | 326022.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 75439.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 25681.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 41670.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 1410.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 36534.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 6.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 4599.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 185342.42 | 326022.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler | 0.00 | 326022.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 75439.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 25681.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | ElevatorLift | 7125.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLightsFan | 57.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
MiscPlug | 34487.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 1410.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 36534.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 6.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Water Heater | 4599.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 637.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 337.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 955.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 164.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 2279.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 85.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 339.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 9.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 186.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4357.82 | 637.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 127.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 67.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 191.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 32.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 457.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 17.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 68.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 1.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 37.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 874.68 | 127.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 127.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 67.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 191.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 32.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 457.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 17.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 68.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 1.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 37.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 874.68 | 127.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
AirTerminal:SingleDuct:VAV:ReheatDesign Size Maximum Air Flow Rate [m3/s] | Design Size Constant Minimum Air Flow Fraction | User-Specified Constant Minimum Air Flow Fraction | Design Size Minimum Air Flow Rate [m3/s] | Design Size Maximum Flow Fraction during Reheat [] | User-Specified Maximum Flow Fraction during Reheat [] | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | Design Size Maximum Reheat Water Flow Rate [m3/s] | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | |
CORE_BOTTOM VAV BOX COMPONENT | 3.10 | 0.241823 | 0.260000 | 0.805790 | 0.644860 | 0.500000 | 0.001576 | 0.000144 | 0.805790 | 12.80 | 0.008000 |
CORE_MID VAV BOX COMPONENT | 2.53 | 0.296782 | 0.315000 | 0.795460 | 0.791419 | 0.500000 | 0.001284 | 0.000229 | 0.889541 | 12.80 | 0.008000 |
CORE_TOP VAV BOX COMPONENT | 2.64 | 0.284075 | 0.311000 | 0.820488 | 0.757535 | 0.500000 | 0.001341 | 0.000408 | 1.59 | 12.80 | 0.008000 |
PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | 0.812194 | 0.194524 | 0.213000 | 0.172997 | 0.518732 | 0.500000 | 0.001959 | 0.000187 | 0.728244 | 12.80 | 0.008000 |
PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | 0.977380 | 0.102337 | 0.200000 | 0.195476 | 0.300000 | 0.500000 | 0.003723 | 0.000122 | 0.476192 | 12.80 | 0.008000 |
PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | 1.29 | 0.122622 | 0.200000 | 0.257690 | 0.326991 | 0.500000 | 0.003107 | 0.000188 | 0.734362 | 12.80 | 0.008000 |
PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | 1.10 | 0.091333 | 0.200000 | 0.219012 | 0.300000 | 0.500000 | 0.004172 | 0.000123 | 0.480653 | 12.80 | 0.008000 |
PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | 0.638689 | 0.247369 | 0.266000 | 0.169891 | 0.659650 | 0.500000 | 0.001540 | 0.000146 | 0.569246 | 12.80 | 0.008000 |
PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | 0.800665 | 0.124923 | 0.200000 | 0.160133 | 0.333129 | 0.500000 | 0.003050 | 0.000096 | 0.375328 | 12.80 | 0.008000 |
PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | 1.03 | 0.153083 | 0.200000 | 0.206414 | 0.408220 | 0.500000 | 0.002489 | 0.000147 | 0.575107 | 12.80 | 0.008000 |
PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | 0.867617 | 0.115276 | 0.200000 | 0.173523 | 0.307402 | 0.500000 | 0.003305 | 0.000097 | 0.379201 | 12.80 | 0.008000 |
PERIMETER_MID_ZN_3 VAV BOX COMPONENT | 0.710977 | 0.222218 | 0.236000 | 0.167791 | 0.592580 | 0.500000 | 0.001715 | 0.000145 | 0.566556 | 12.80 | 0.008000 |
PERIMETER_MID_ZN_2 VAV BOX COMPONENT | 0.968459 | 0.103279 | 0.200000 | 0.193692 | 0.300000 | 0.500000 | 0.003689 | 0.000096 | 0.372919 | 12.80 | 0.008000 |
PERIMETER_MID_ZN_1 VAV BOX COMPONENT | 1.18 | 0.133479 | 0.200000 | 0.236730 | 0.355943 | 0.500000 | 0.002854 | 0.000147 | 0.571804 | 12.80 | 0.008000 |
PERIMETER_MID_ZN_4 VAV BOX COMPONENT | 1.02 | 0.098289 | 0.200000 | 0.203512 | 0.300000 | 0.500000 | 0.003876 | 0.000097 | 0.376893 | 12.80 | 0.008000 |
Design Size Rated Capacity [W] | Design Size Maximum Water Flow Rate [m3/s] | Design Size U-Factor Times Area Value [W/K] | |
CORE_BOTTOM VAV BOX REHEAT COIL | 16502.30 | 0.000144 | 383.31 |
CORE_MID VAV BOX REHEAT COIL | 26162.29 | 0.000229 | 690.94 |
CORE_TOP VAV BOX REHEAT COIL | 46645.01 | 0.000408 | 1230.66 |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | 21338.52 | 0.000187 | 562.58 |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | 13952.51 | 0.000122 | 367.84 |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | 21517.58 | 0.000188 | 567.30 |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | 14083.04 | 0.000123 | 371.28 |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | 16684.97 | 0.000146 | 439.95 |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | 11000.42 | 0.000096 | 290.05 |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | 16856.47 | 0.000147 | 444.47 |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | 11113.76 | 0.000097 | 293.04 |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | 16606.50 | 0.000145 | 437.89 |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | 10930.06 | 0.000096 | 288.20 |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | 16760.06 | 0.000147 | 441.94 |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | 11046.34 | 0.000097 | 291.27 |
PACU_VAV_BOT HEATING COIL | 47996.91 | 0.000420 | 747.60 |
PACU_VAV_MID HEATING COIL | 49080.55 | 0.000429 | 753.21 |
PACU_VAV_TOP HEATING COIL | 49198.25 | 0.000430 | 771.38 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PACU_VAV_BOT | 3.22 | 1.52 | 6.44 | 2.34 | 5.65 | 5.65 | 0.300000 | 0.414965 | 5.65 |
PACU_VAV_MID | 3.20 | 1.60 | 6.41 | 2.78 | 5.34 | 5.34 | 0.300000 | 0.520057 | 5.34 |
PACU_VAV_TOP | 3.41 | 1.67 | 6.81 | 4.01 | 6.12 | 6.12 | 0.300000 | 0.654896 | 6.12 |
Maximum Outdoor Air Flow Rate [m3/s] | |
PACU_VAV_BOT_OA_CONTROLLER | 5.65 |
PACU_VAV_MID_OA_CONTROLLER | 5.34 |
PACU_VAV_TOP_OA_CONTROLLER | 6.12 |
Design Size High Speed Rated Air Flow Rate [m3/s] | Design Size High Speed Gross Rated Total Cooling Capacity [W] | Design Size High Speed Rated Sensible Heat Ratio | Design Size Low Speed Rated Air Flow Rate [m3/s] | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | Design Size Low Speed Gross Rated Sensible Heat Ratio | |
PACU_VAV_BOT COOLING COIL | 5.65 | 93545.07 | 0.800655 | 1.88 | 31178.57 | 0.800655 |
PACU_VAV_MID COOLING COIL | 5.34 | 88415.30 | 0.800655 | 1.78 | 29468.82 | 0.800655 |
PACU_VAV_TOP COOLING COIL | 6.12 | 101329.65 | 0.800655 | 2.04 | 33773.17 | 0.800655 |
Design Size Maximum Flow Rate [m3/s] | |
PACU_VAV_BOT FAN | 5.65 |
PACU_VAV_MID FAN | 5.34 |
PACU_VAV_TOP FAN | 6.12 |
Maximum Actuated Flow [m3/s] | |
PACU_VAV_BOT_HEATC_CONTROLLER | 0.000420 |
PACU_VAV_MID_HEATC_CONTROLLER | 0.000429 |
PACU_VAV_TOP_HEATC_CONTROLLER | 0.000430 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
HEATSYS1 | 0.003652 | 0.438271 |
SWHSYS1 | 0.000054 | 0.006435 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | Design Minimum Flow Rate [m3/s] | |
HEATSYS1 PUMP | 0.003652 | 1099.90 | 0.000000 |
Design Size Nominal Capacity [W] | User-Specified Nominal Capacity [W] | Design Size Design Water Flow Rate [m3/s] | |
HEATSYS1 BOILER | 417475.55 | 417475.55 | 0.003652 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | |
SWHSYS1 PUMP | 0.000054 | 6.85 |
Use Side Design Flow Rate [m3/s] | |
SWHSYS1 WATER HEATER | 0.000054 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
PERIMETER_TOP_ZN_3_WALL_NORTH | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | |
PERIMETER_TOP_ZN_2_WALL_EAST | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | |
PERIMETER_TOP_ZN_1_WALL_SOUTH | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | |
PERIMETER_TOP_ZN_4_WALL_WEST | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | |
PERIMETER_BOT_ZN_3_WALL_NORTH | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | |
PERIMETER_BOT_ZN_2_WALL_EAST | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | |
PERIMETER_BOT_ZN_1_WALL_SOUTH | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | |
PERIMETER_BOT_ZN_4_WALL_WEST | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | |
PERIMETER_MID_ZN_3_WALL_NORTH | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | |
PERIMETER_MID_ZN_2_WALL_EAST | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | |
PERIMETER_MID_ZN_1_WALL_SOUTH | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | |
PERIMETER_MID_ZN_4_WALL_WEST | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
VersionVersion ID | |
1 | 22.1 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 8.60 | 2.80 | -4.10 | -8.80 | -2.20 | 0.30 | 6.70 | 10.10 | 16.50 | 20.60 | 19.20 | 14.70 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Great Falls Intl Arpt MT USA TMY3 WMO#=727750 | 47.47 | -111.38 | -7.00 | 1117.00 | 88606 | 1.0531 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 7.03 | 29.40 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | OfficeMedium | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 18 | 167 | 24 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | CORE_BOTTOM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 1.37 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 0.00 | 2.74 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
2 | TOPFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 11.28 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 10.67 | 11.89 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 10 | 0 | 0 | No |
3 | MIDFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 7.32 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 6.71 | 7.92 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 14 | 0 | 0 | No |
4 | FIRSTFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 3.35 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 2.74 | 3.96 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 14 | 0 | 0 | No |
5 | CORE_MID | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 5.33 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 3.96 | 6.71 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
6 | CORE_TOP | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 9.30 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 7.92 | 10.67 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
7 | PERIMETER_TOP_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 9.30 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 7.92 | 10.67 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 71.65 | 65.26 | 6 | 1 | 0 | Yes |
8 | PERIMETER_TOP_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 9.30 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 7.92 | 10.67 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 47.77 | 43.51 | 6 | 1 | 0 | Yes |
9 | PERIMETER_TOP_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 9.30 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 7.92 | 10.67 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 71.65 | 65.26 | 6 | 1 | 0 | Yes |
10 | PERIMETER_TOP_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 9.30 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 7.92 | 10.67 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 47.77 | 43.51 | 6 | 1 | 0 | Yes |
11 | PERIMETER_BOT_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 1.37 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 0.00 | 2.74 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 67.75 | 65.26 | 6 | 5 | 0 | Yes |
12 | PERIMETER_BOT_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 1.37 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 0.00 | 2.74 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 45.82 | 43.51 | 6 | 3 | 0 | Yes |
13 | PERIMETER_BOT_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 1.37 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 0.00 | 2.74 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 67.75 | 65.26 | 6 | 5 | 0 | Yes |
14 | PERIMETER_BOT_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 1.37 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 0.00 | 2.74 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 45.82 | 43.51 | 6 | 3 | 0 | Yes |
15 | PERIMETER_MID_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 5.33 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 3.96 | 6.71 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 71.65 | 65.26 | 6 | 1 | 0 | Yes |
16 | PERIMETER_MID_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 5.33 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 3.96 | 6.71 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 47.77 | 43.51 | 6 | 1 | 0 | Yes |
17 | PERIMETER_MID_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 5.33 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 3.96 | 6.71 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 71.65 | 65.26 | 6 | 1 | 0 | Yes |
18 | PERIMETER_MID_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 5.33 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 3.96 | 6.71 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 47.77 | 43.51 | 6 | 1 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | CORE_BOTTOM | 983.54 | 52.9 | 18.579 | 5.382E-002 | 8.699 | 89.459 | 0.000 | 0.000 | 0.000 | 0.000 | 98.158 | No |
2 | TOPFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
3 | MIDFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
4 | FIRSTFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
5 | CORE_MID | 983.54 | 52.9 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
6 | CORE_TOP | 983.54 | 52.9 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
7 | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
8 | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 8.699 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
9 | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
10 | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
11 | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
12 | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 8.699 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
13 | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
14 | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
15 | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
16 | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 8.699 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
17 | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
18 | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | Cooling Effect Calculation | Ankle Draft Calculation | |
1 | CORE_BOTTOM | BLDG_OCC_SCH_WO_SB | CORE_BOTTOM | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
2 | CORE_MID | BLDG_OCC_SCH_WO_SB | CORE_MID | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
3 | CORE_TOP | BLDG_OCC_SCH_WO_SB | CORE_TOP | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
4 | PERIMETER_TOP_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
5 | PERIMETER_TOP_ZN_2 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
6 | PERIMETER_TOP_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
7 | PERIMETER_TOP_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
8 | PERIMETER_BOT_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
9 | PERIMETER_BOT_ZN_2 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
10 | PERIMETER_BOT_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
11 | PERIMETER_BOT_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
12 | PERIMETER_MID_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
13 | PERIMETER_MID_ZN_2 | BLDG_OCC_SCH_W_SB | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
14 | PERIMETER_MID_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
15 | PERIMETER_MID_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | CORE_BOTTOM_LIGHTS | LTG_SCH_OFFICE | CORE_BOTTOM | 983.54 | 52.9 | 8556.149 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 8556.149 |
2 | CORE_MID_LIGHTS | LTG_SCH_OFFICE | CORE_MID | 983.54 | 52.9 | 8556.149 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 8556.149 |
3 | CORE_TOP_LIGHTS | LTG_SCH_OFFICE | CORE_TOP | 983.54 | 52.9 | 8556.149 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 8556.149 |
4 | PERIMETER_TOP_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 1803.711 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1803.711 |
5 | PERIMETER_TOP_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 1141.898 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1141.898 |
6 | PERIMETER_TOP_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 1803.711 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1803.711 |
7 | PERIMETER_TOP_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 1141.823 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1141.823 |
8 | PERIMETER_BOT_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 1803.711 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1803.711 |
9 | PERIMETER_BOT_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 1141.898 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1141.898 |
10 | PERIMETER_BOT_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1803.711 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1803.711 |
11 | PERIMETER_BOT_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 1141.823 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1141.823 |
12 | PERIMETER_MID_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 1803.711 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1803.711 |
13 | PERIMETER_MID_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 1141.898 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1141.898 |
14 | PERIMETER_MID_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 1803.711 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1803.711 |
15 | PERIMETER_MID_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 1141.823 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1141.823 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | ELEVATOR_LIFT_RUNNING | ELEVATOR_RUNNING_SCH | CORE_BOTTOM | 983.54 | 52.9 | 76724.000 | 78.008 | 1449.300 | 0.000 | 0.500 | 0.000 | 0.500 | ElevatorLift | 0.000 | 4561.242 |
2 | ELEVATOR_LIFT_STANDBY | ELEVATOR_STANDBY_SCH | CORE_BOTTOM | 983.54 | 52.9 | 3200.000 | 3.254 | 60.447 | 0.000 | 0.500 | 0.000 | 0.500 | ElevatorLift | 2563.936 | 3200.000 |
3 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_ADD_DF | CORE_BOTTOM | 983.54 | 52.9 | 125.000 | 0.127 | 2.361 | 0.000 | 0.500 | 0.000 | 0.500 | ElevatorLightsFan | 0.000 | 86.250 |
4 | CORE_BOTTOM_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_BOTTOM | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
5 | CORE_MID_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_MID | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
6 | CORE_TOP_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_TOP | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
7 | PERIMETER_TOP_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
8 | PERIMETER_TOP_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
9 | PERIMETER_TOP_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
10 | PERIMETER_TOP_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
11 | PERIMETER_BOT_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
12 | PERIMETER_BOT_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
13 | PERIMETER_BOT_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
14 | PERIMETER_BOT_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
15 | PERIMETER_MID_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
16 | PERIMETER_MID_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
17 | PERIMETER_MID_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
18 | PERIMETER_MID_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 3.065 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | INTERIORFURNISHINGS | 2 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
3 | DROPCEILING | 4 | 1 | 3 | 0.167 | 4.488 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 7 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | INT_SLAB_FLOOR | 12 | 2 | 7 | 0.167 | 3.839 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
6 | INT_SLAB_CEILING | 13 | 2 | 7 | 0.167 | 3.839 | 0.900 | 0.900 | 0.700 | 0.700 | VeryRough |
7 | NONRES_ROOF | 17 | 3 | 3 | 0.167 | 0.1864 | 0.900 | 0.900 | 0.700 | 0.700 | Rough |
8 | NONRES_EXT_WALL_GRD | 20 | 4 | 7 | 0.167 | 0.7597 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
9 | NONRES_EXT_WALL_MID | 21 | 4 | 7 | 0.167 | 0.7464 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
10 | NONRES_EXT_WALL_TOP | 22 | 4 | 7 | 0.167 | 0.9868 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
11 | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 39 | 2 | 7 | 0.167 | 0.2198 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
12 | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 40 | 2 | 7 | 0.167 | 0.2318 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 41 | 2 | 7 | 0.167 | 0.2198 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 42 | 2 | 7 | 0.167 | 0.2318 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | CORE_BOT_ZN_5_FLOOR_FFACTOR | 43 | 2 | 8 | 0.167 | 0.5650E-02 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.3263 |
2 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
3 | AC02 ACOUSTIC CEILING | 0.0127 | 0.057 | 288.000 | 1339.000 | 0.2228 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
7 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
8 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
9 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
10 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
11 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 5.307 |
12 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
13 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
14 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
15 | NONRES_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 1.082 |
16 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
17 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
18 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
19 | NONRES_EXTERIOR_WALL_INSULATION_MID | 0.0000 | 0.000 | 0.000 | 0.000 | 1.106 |
20 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
21 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
22 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
23 | NONRES_EXTERIOR_WALL_INSULATION_TOP | 0.0000 | 0.000 | 0.000 | 0.000 | 0.7793 |
24 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
25 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.474 |
26 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
27 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.237 |
28 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
29 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.474 |
30 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
31 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.236 |
32 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
33 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 176.9 |
34 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 3.0649134 | 3.0649134 | 3.0649134 | |
3 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
4 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
5 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
6 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
7 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
8 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
9 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
10 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
11 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
12 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
13 | 3 | -0.21589802E-09 | 0.15643069E-09 | -0.21589802E-09 | 0.12999471E-21 |
14 | 2 | 0.50772448E-02 | 0.30006816E-02 | 0.50772448E-02 | -0.13693132E-08 |
15 | 1 | -2.5944910 | 1.4597758 | -2.5944910 | 0.76344767E-02 |
16 | 0 | 7.0433378 | 2.9911476 | 7.0433378 | |
17 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
18 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
19 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
20 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
21 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
22 | 7 | 0.43260499E-16 | 0.34524919E-16 | 0.52793240E-17 | 0.0000000 |
23 | 6 | 0.69434179E-09 | 0.98085174E-11 | 0.18162501E-10 | -0.40870994E-12 |
24 | 5 | -0.12888762E-04 | 0.28373718E-06 | -0.16918523E-06 | 0.92361873E-08 |
25 | 4 | 0.25174112E-01 | 0.33697681E-03 | 0.22646198E-03 | -0.31467795E-04 |
26 | 3 | -3.7600775 | 0.27170599E-01 | -0.48495626E-01 | 0.94171705E-02 |
27 | 2 | 51.553741 | 0.22121684 | 1.2284947 | -0.25833933 |
28 | 1 | -128.86110 | 0.21944682 | -5.1479470 | 1.1228340 |
29 | 0 | 81.526494 | 0.16043334E-01 | 4.4519351 | |
30 | 7 | 0.52793240E-17 | 0.34524919E-16 | 0.43260499E-16 | 0.0000000 |
31 | 6 | 0.18162501E-10 | 0.98085174E-11 | 0.69434179E-09 | -0.40870994E-12 |
32 | 5 | -0.16918523E-06 | 0.28373718E-06 | -0.12888762E-04 | 0.92361873E-08 |
33 | 4 | 0.22646198E-03 | 0.33697681E-03 | 0.25174112E-01 | -0.31467795E-04 |
34 | 3 | -0.48495626E-01 | 0.27170599E-01 | -3.7600775 | 0.94171705E-02 |
35 | 2 | 1.2284947 | 0.22121684 | 51.553741 | -0.25833933 |
36 | 1 | -5.1479470 | 0.21944682 | -128.86110 | 1.1228340 |
37 | 0 | 4.4519351 | 0.16043334E-01 | 81.526494 | |
38 | 3 | -0.62854340E-06 | 0.84784826E-09 | -0.38512804E-05 | 0.91756347E-17 |
39 | 2 | 0.78257096 | 0.11428808E-02 | 1.0614277 | -0.73836085E-06 |
40 | 1 | -21.991499 | 0.76199851E-01 | -6.3161914 | 0.20349372 |
41 | 0 | 21.357363 | 0.71091016E-01 | 5.4032014 | |
42 | 7 | -0.31468885E-12 | 0.58742715E-14 | -0.96802560E-13 | 0.16792992E-15 |
43 | 6 | 0.28872123E-07 | 0.21416477E-09 | 0.66123209E-08 | -0.13627602E-12 |
44 | 5 | -0.19112651E-03 | 0.18301600E-05 | -0.98293898E-04 | 0.65360363E-08 |
45 | 4 | 0.29333920 | 0.88954174E-03 | 0.10011225 | -0.33739231E-04 |
46 | 3 | -7.2899446 | 0.27524297E-01 | -2.3459205 | 0.29124746E-01 |
47 | 2 | 40.949034 | 0.97737712E-01 | 15.293846 | -0.33420785 |
48 | 1 | -80.605481 | 0.44056480E-01 | -29.167461 | 1.0798913 |
49 | 0 | 46.824338 | 0.88531397E-03 | 16.290617 | |
50 | 7 | -0.30618227E-12 | 0.12614254E-14 | -0.97456297E-13 | 0.16278992E-15 |
51 | 6 | 0.29029541E-07 | 0.21075172E-09 | 0.66470638E-08 | -0.13712239E-12 |
52 | 5 | -0.19192439E-03 | 0.17992386E-05 | -0.98693455E-04 | 0.65698920E-08 |
53 | 4 | 0.29427084 | 0.87374093E-03 | 0.10044741 | -0.33870887E-04 |
54 | 3 | -7.3083902 | 0.27014250E-01 | -2.3513943 | 0.29215155E-01 |
55 | 2 | 41.009863 | 0.95860246E-01 | 15.316286 | -0.33488536 |
56 | 1 | -80.652088 | 0.43184114E-01 | -29.187576 | 1.0808846 |
57 | 0 | 46.824338 | 0.86726935E-03 | 16.290137 | |
58 | 7 | -0.27636417E-12 | 0.12990813E-14 | -0.82271001E-13 | 0.80162457E-16 |
59 | 6 | 0.26158967E-07 | 0.26982527E-09 | 0.60134738E-08 | -0.12176112E-12 |
60 | 5 | -0.17726759E-03 | 0.23481051E-05 | -0.91336903E-04 | 0.59516496E-08 |
61 | 4 | 0.27699908 | 0.11597994E-02 | 0.94241662E-01 | -0.31446529E-04 |
62 | 3 | -6.9660490 | 0.36401088E-01 | -2.2498311 | 0.27538282E-01 |
63 | 2 | 39.880486 | 0.13088809 | 14.898993 | -0.32230875 |
64 | 1 | -79.786295 | 0.59645051E-01 | -28.813249 | 1.0624348 |
65 | 0 | 46.824344 | 0.12114519E-02 | 16.299244 | |
66 | 7 | -0.19168505E-08 | -0.51383041E-15 | 0.68469349E-14 | -0.93730203E-16 |
67 | 6 | 0.61617009E-05 | 0.42103975E-08 | 0.31882761E-02 | -0.26745931E-04 |
68 | 5 | -0.44250412E-03 | 0.24935927E-05 | -0.22363399 | 0.19553507E-02 |
69 | 4 | 0.10175003E-01 | 0.11350545E-03 | 4.8280370 | -0.45250478E-01 |
70 | 3 | -0.89340535E-01 | 0.90260008E-03 | -38.012894 | 0.39855955 |
71 | 2 | 0.31721614 | 0.15015396E-02 | 116.46736 | -1.4177174 |
72 | 1 | -0.45784565 | 0.45746588E-03 | -143.89754 | 2.0488794 |
73 | 0 | 0.22322007 | 0.11078117E-04 | 60.838472 | |
74 | 7 | -0.18147523E-08 | -0.43765969E-15 | 0.59880535E-14 | -0.82299290E-16 |
75 | 6 | 0.64914511E-05 | 0.44428550E-08 | 0.31873263E-02 | -0.26737964E-04 |
76 | 5 | -0.46689866E-03 | 0.26323880E-05 | -0.22358000 | 0.19548742E-02 |
77 | 4 | 0.10740407E-01 | 0.11982633E-03 | 4.8271378 | -0.45241835E-01 |
78 | 3 | -0.94318369E-01 | 0.95296379E-03 | -38.007814 | 0.39850340 |
79 | 2 | 0.33490849 | 0.15853305E-02 | 116.45748 | -1.4175852 |
80 | 1 | -0.48339250 | 0.48313585E-03 | -143.89172 | 2.0487838 |
81 | 0 | 0.23567793 | 0.11657420E-04 | 60.838472 | |
82 | 7 | -0.19168505E-08 | -0.51383063E-15 | 0.68469351E-14 | -0.93730206E-16 |
83 | 6 | 0.61617009E-05 | 0.42103975E-08 | 0.31882761E-02 | -0.26745931E-04 |
84 | 5 | -0.44250412E-03 | 0.24935927E-05 | -0.22363399 | 0.19553507E-02 |
85 | 4 | 0.10175003E-01 | 0.11350545E-03 | 4.8280370 | -0.45250478E-01 |
86 | 3 | -0.89340535E-01 | 0.90260008E-03 | -38.012894 | 0.39855955 |
87 | 2 | 0.31721614 | 0.15015396E-02 | 116.46736 | -1.4177174 |
88 | 1 | -0.45784565 | 0.45746588E-03 | -143.89754 | 2.0488794 |
89 | 0 | 0.22322007 | 0.11078117E-04 | 60.838472 | |
90 | 7 | -0.18146260E-08 | -0.43662845E-15 | 0.62700332E-14 | -0.82012168E-16 |
91 | 6 | 0.64918823E-05 | 0.44431590E-08 | 0.31873251E-02 | -0.26737954E-04 |
92 | 5 | -0.46693053E-03 | 0.26325692E-05 | -0.22357993 | 0.19548736E-02 |
93 | 4 | 0.10741146E-01 | 0.11983458E-03 | 4.8271366 | -0.45241823E-01 |
94 | 3 | -0.94324870E-01 | 0.95302955E-03 | -38.007807 | 0.39850333 |
95 | 2 | 0.33493160 | 0.15854399E-02 | 116.45746 | -1.4175850 |
96 | 1 | -0.48342587 | 0.48316934E-03 | -143.89172 | 2.0487836 |
97 | 0 | 0.23569420 | 0.11658190E-04 | 60.838472 | |
98 | 8 | 0.57026216E-10 | -0.29656739E-13 | 0.26072253E-13 | -0.16907584E-15 |
99 | 7 | -0.80728763E-07 | 0.14958947E-11 | -0.10196182E-04 | 0.85534123E-07 |
100 | 6 | 0.59163330E-05 | 0.23390251E-08 | 0.39199948E-02 | -0.33137873E-04 |
101 | 5 | -0.14678961E-03 | 0.29443049E-06 | -0.24001665 | 0.21083805E-02 |
102 | 4 | 0.15257864E-02 | 0.63469284E-05 | 4.9653291 | -0.46676227E-01 |
103 | 3 | -0.74362311E-02 | 0.30151767E-04 | -38.474208 | 0.40407555 |
104 | 2 | 0.17883035E-01 | 0.32406056E-04 | 117.10039 | -1.4265819 |
105 | 1 | -0.20235698E-01 | 0.62001922E-05 | -144.19380 | 2.0537490 |
106 | 0 | 0.84795330E-02 | 0.69040512E-07 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | Conductance (Before Adjusted) {W/m2-K} | Convection Coefficient Adjustment Ratio | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | WINDOW_U_0.36_SHGC_EAST_0.4 | 35 | 1 | VerySmooth | 2.045 | 2.045 | 1.000 | 0.401 | ||
2 | WINDOW_U_0.36_SHGC_SOUTH_0.4 | 36 | 1 | VerySmooth | 2.045 | 2.045 | 1.000 | 0.401 | ||
3 | WINDOW_U_0.36_SHGC_WEST_0.4 | 37 | 1 | VerySmooth | 2.045 | 2.045 | 1.000 | 0.401 | ||
4 | WINDOW_U_0.36_SHGC_NORTH_0.4 | 38 | 1 | VerySmooth | 2.045 | 2.045 | 1.000 | 0.401 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | GLAZING LAYER EAST | SpectralAverage | 3.65598E-002 | 0.31435 | 0.48154 | 0.48154 | 0.44000 | 0.13397 | 0.17027 | 0.00000 | 0.84000 | 0.84000 | 0.11562 | 1.00000 | No | |
2 | GLAZING LAYER SOUTH | SpectralAverage | 3.65598E-002 | 0.31435 | 0.48154 | 0.48154 | 0.44000 | 0.13397 | 0.17027 | 0.00000 | 0.84000 | 0.84000 | 0.11562 | 1.00000 | No | |
3 | GLAZING LAYER WEST | SpectralAverage | 3.65598E-002 | 0.31435 | 0.48154 | 0.48154 | 0.44000 | 0.13397 | 0.17027 | 0.00000 | 0.84000 | 0.84000 | 0.11562 | 1.00000 | No | |
4 | GLAZING LAYER NORTH | SpectralAverage | 3.65598E-002 | 0.31435 | 0.48154 | 0.48154 | 0.44000 | 0.13397 | 0.17027 | 0.00000 | 0.84000 | 0.84000 | 0.11562 | 1.00000 | No |
Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | PolygonClipping | Periodic | 30 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
Enclosure Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Enclosures | |
1 | PERIMETER_TOP_ZN_3 | 1 | 0 |
2 | PERIMETER_TOP_ZN_2 | 1 | 0 |
3 | PERIMETER_TOP_ZN_1 | 1 | 0 |
4 | PERIMETER_TOP_ZN_4 | 1 | 0 |
5 | PERIMETER_BOT_ZN_3 | 3 | 0 |
6 | PERIMETER_BOT_ZN_2 | 2 | 0 |
7 | PERIMETER_BOT_ZN_1 | 3 | 0 |
8 | PERIMETER_BOT_ZN_4 | 2 | 0 |
9 | PERIMETER_MID_ZN_3 | 1 | 0 |
10 | PERIMETER_MID_ZN_2 | 1 | 0 |
11 | PERIMETER_MID_ZN_1 | 1 | 0 |
12 | PERIMETER_MID_ZN_4 | 1 | 0 |
Enclosure Name | Number of Adjacent Enclosures with Windows | Adjacent Enclosure Names - 1st 100 (max) | |
1 | PERIMETER_TOP_ZN_3 | 0 | |
2 | PERIMETER_TOP_ZN_2 | 0 | |
3 | PERIMETER_TOP_ZN_1 | 0 | |
4 | PERIMETER_TOP_ZN_4 | 0 | |
5 | PERIMETER_BOT_ZN_3 | 0 | |
6 | PERIMETER_BOT_ZN_2 | 0 | |
7 | PERIMETER_BOT_ZN_1 | 0 | |
8 | PERIMETER_BOT_ZN_4 | 0 | |
9 | PERIMETER_MID_ZN_3 | 0 | |
10 | PERIMETER_MID_ZN_2 | 0 | |
11 | PERIMETER_MID_ZN_1 | 0 | |
12 | PERIMETER_MID_ZN_4 | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 0.3785 | 29307.1 | 27.185 | 0.8451 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | CORE_BOT_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
2 | CORE_BOT_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
3 | CORE_BOT_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
4 | CORE_BOT_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
5 | CORE_BOT_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
6 | CORE_BOT_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
7 | CORE_BOTTOM_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
8 | PERIMETER_TOP_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
9 | PERIMETER_TOP_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
10 | PERIMETER_TOP_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
11 | PERIMETER_TOP_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
12 | iz-PERIMETER_TOP_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
13 | iz-PERIMETER_TOP_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
14 | iz-PERIMETER_TOP_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
15 | iz-PERIMETER_TOP_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
16 | iz-CORE_TOP_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
17 | BUILDING_ROOF | 0 | 1660.73 | 183.01 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
18 | PERIMETER_MID_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
19 | PERIMETER_MID_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
20 | PERIMETER_MID_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
21 | PERIMETER_MID_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
22 | iz-PERIMETER_MID_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
23 | iz-PERIMETER_MID_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
24 | iz-PERIMETER_MID_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
25 | iz-PERIMETER_MID_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
26 | iz-CORE_MID_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
27 | iz-PERIMETER_TOP_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
28 | iz-PERIMETER_TOP_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
29 | iz-PERIMETER_TOP_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
30 | iz-PERIMETER_TOP_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
31 | iz-CORE_TOP_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
32 | PERIMETER_BOT_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
33 | PERIMETER_BOT_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
34 | PERIMETER_BOT_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
35 | PERIMETER_BOT_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
36 | iz-PERIMETER_BOT_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
37 | iz-PERIMETER_BOT_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
38 | iz-PERIMETER_BOT_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
39 | iz-PERIMETER_BOT_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
40 | iz-CORE_BOT_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
41 | iz-PERIMETER_MID_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
42 | iz-PERIMETER_MID_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
43 | iz-PERIMETER_MID_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
44 | iz-PERIMETER_MID_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
45 | iz-CORE_MID_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
46 | CORE_MID_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
47 | CORE_MID_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
48 | CORE_MID_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
49 | CORE_MID_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
50 | CORE_MID_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
51 | CORE_MID_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
52 | CORE_MID_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
53 | CORE_TOP_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
54 | CORE_TOP_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
55 | CORE_TOP_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
56 | CORE_TOP_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
57 | CORE_TOP_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
58 | CORE_TOP_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
59 | CORE_TOP_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
60 | PERIMETER_TOP_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
61 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
62 | PERIMETER_TOP_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
63 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
64 | iz-CORE_TOP_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
65 | PERIMETER_TOP_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
66 | PERIMETER_TOP_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
67 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
68 | PERIMETER_TOP_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
69 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
70 | PERIMETER_TOP_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
71 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
72 | iz-CORE_TOP_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
73 | PERIMETER_TOP_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
74 | PERIMETER_TOP_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
75 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
76 | PERIMETER_TOP_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
77 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
78 | PERIMETER_TOP_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
79 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
80 | iz-CORE_TOP_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
81 | PERIMETER_TOP_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
82 | PERIMETER_TOP_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
83 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
84 | PERIMETER_TOP_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
85 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
86 | PERIMETER_TOP_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
87 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
88 | iz-CORE_TOP_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
89 | PERIMETER_TOP_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
90 | PERIMETER_TOP_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
91 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
92 | PERIMETER_BOT_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
93 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
94 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
95 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
96 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
97 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
98 | PERIMETER_BOT_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
99 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
100 | iz-CORE_BOT_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
101 | PERIMETER_BOT_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
102 | PERIMETER_BOT_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
103 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
104 | PERIMETER_BOT_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
105 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
106 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
107 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
108 | PERIMETER_BOT_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
109 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
110 | iz-CORE_BOT_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
111 | PERIMETER_BOT_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
112 | PERIMETER_BOT_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
113 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
114 | PERIMETER_BOT_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
115 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
116 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
117 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
118 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
119 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
120 | PERIMETER_BOT_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
121 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
122 | iz-CORE_BOT_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
123 | PERIMETER_BOT_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
124 | PERIMETER_BOT_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
125 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
126 | PERIMETER_BOT_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
127 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
128 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
129 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
130 | PERIMETER_BOT_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
131 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
132 | iz-CORE_BOT_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
133 | PERIMETER_BOT_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
134 | PERIMETER_BOT_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
135 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
136 | PERIMETER_MID_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
137 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
138 | PERIMETER_MID_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
139 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
140 | iz-CORE_MID_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
141 | PERIMETER_MID_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
142 | PERIMETER_MID_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
143 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
144 | PERIMETER_MID_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
145 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
146 | PERIMETER_MID_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
147 | iz-PERIMETER_MID_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
148 | iz-CORE_MID_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
149 | PERIMETER_MID_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
150 | PERIMETER_MID_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
151 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
152 | PERIMETER_MID_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
153 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
154 | PERIMETER_MID_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
155 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
156 | iz-CORE_MID_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
157 | PERIMETER_MID_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
158 | PERIMETER_MID_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
159 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
160 | PERIMETER_MID_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
161 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
162 | PERIMETER_MID_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
163 | iz-PERIMETER_MID_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
164 | iz-CORE_MID_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
165 | PERIMETER_MID_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
166 | PERIMETER_MID_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
167 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | PERIMETER_TOP_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 3.509E-002 | 1.693E-004 | 2.563E-004 | 0.222 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | PERIMETER_TOP_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 2.339E-002 | 1.782E-004 | 2.563E-004 | 0.234 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | PERIMETER_TOP_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 3.509E-002 | 1.693E-004 | 2.563E-004 | 0.222 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | PERIMETER_TOP_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 2.339E-002 | 1.782E-004 | 2.563E-004 | 0.234 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | PERIMETER_BOT_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 3.509E-002 | 1.693E-004 | 2.492E-004 | 0.222 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | PERIMETER_BOT_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 2.339E-002 | 1.782E-004 | 2.509E-004 | 0.234 | 0.000 | 0.000 | 0.224 | 0.000 |
7 | PERIMETER_BOT_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 3.509E-002 | 1.693E-004 | 2.492E-004 | 0.222 | 0.000 | 0.000 | 0.224 | 0.000 |
8 | PERIMETER_BOT_ZN_1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 0.679 | 3.273E-003 | 4.819E-003 | 4.296 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | PERIMETER_BOT_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 2.339E-002 | 1.782E-004 | 2.509E-004 | 0.234 | 0.000 | 0.000 | 0.224 | 0.000 |
10 | PERIMETER_MID_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 3.509E-002 | 1.693E-004 | 2.563E-004 | 0.222 | 0.000 | 0.000 | 0.224 | 0.000 |
11 | PERIMETER_MID_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 2.339E-002 | 1.782E-004 | 2.563E-004 | 0.234 | 0.000 | 0.000 | 0.224 | 0.000 |
12 | PERIMETER_MID_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 3.509E-002 | 1.693E-004 | 2.563E-004 | 0.222 | 0.000 | 0.000 | 0.224 | 0.000 |
13 | PERIMETER_MID_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 2.339E-002 | 1.782E-004 | 2.563E-004 | 0.234 | 0.000 | 0.000 | 0.224 | 0.000 |
14 | FIRSTFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | FIRSTFLOOR_PLENUM | 1660.73 | 0.0 | 5.199E-002 | 3.130E-005 | 2.563E-004 | 9.244E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
15 | MIDFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | MIDFLOOR_PLENUM | 1660.73 | 0.0 | 5.199E-002 | 3.130E-005 | 2.563E-004 | 9.244E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
16 | TOPFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | TOPFLOOR_PLENUM | 1660.73 | 0.0 | 5.199E-002 | 3.130E-005 | 2.790E-005 | 9.244E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | CORE_BOTTOM | Mixing/Well-Stirred |
2 | TOPFLOOR_PLENUM | Mixing/Well-Stirred |
3 | MIDFLOOR_PLENUM | Mixing/Well-Stirred |
4 | FIRSTFLOOR_PLENUM | Mixing/Well-Stirred |
5 | CORE_MID | Mixing/Well-Stirred |
6 | CORE_TOP | Mixing/Well-Stirred |
7 | PERIMETER_TOP_ZN_3 | Mixing/Well-Stirred |
8 | PERIMETER_TOP_ZN_2 | Mixing/Well-Stirred |
9 | PERIMETER_TOP_ZN_1 | Mixing/Well-Stirred |
10 | PERIMETER_TOP_ZN_4 | Mixing/Well-Stirred |
11 | PERIMETER_BOT_ZN_3 | Mixing/Well-Stirred |
12 | PERIMETER_BOT_ZN_2 | Mixing/Well-Stirred |
13 | PERIMETER_BOT_ZN_1 | Mixing/Well-Stirred |
14 | PERIMETER_BOT_ZN_4 | Mixing/Well-Stirred |
15 | PERIMETER_MID_ZN_3 | Mixing/Well-Stirred |
16 | PERIMETER_MID_ZN_2 | Mixing/Well-Stirred |
17 | PERIMETER_MID_ZN_1 | Mixing/Well-Stirred |
18 | PERIMETER_MID_ZN_4 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sky Type | MonthAndDay | Daylighting Control Name | Enclosure Name | Window Name | Reference Point | Daylight Factor | |
1 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 1.3532E-002 |
2 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.3601E-002 |
3 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 1.5191E-002 |
4 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.5250E-002 |
5 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 8.5745E-003 |
6 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 8.6222E-003 |
7 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 4.6026E-003 |
8 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 4.6282E-003 |
9 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 0.1816 |
10 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 0.1047 |
11 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 0.2085 |
12 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 0.1213 |
13 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 0.1202 |
14 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 5.2555E-002 |
15 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 5.0870E-002 |
16 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.9083E-002 |
17 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 1.3535E-002 |
18 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.3623E-002 |
19 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 1.5194E-002 |
20 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.5275E-002 |
21 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 8.5774E-003 |
22 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 8.6363E-003 |
23 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 4.6024E-003 |
24 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 4.6280E-003 |
25 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 8.9569E-002 |
26 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 5.1943E-002 |
27 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 8.7754E-002 |
28 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 4.9959E-002 |
29 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 8.2633E-002 |
30 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 4.1697E-002 |
31 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 5.9724E-002 |
32 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 2.8144E-002 |
33 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 7.8346E-004 |
34 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 7.8639E-004 |
35 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 7.6421E-004 |
36 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 7.6634E-004 |
37 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 6.8188E-004 |
38 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 6.8264E-004 |
39 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 5.3717E-004 |
40 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 5.3805E-004 |
41 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 5.1122E-003 |
42 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 5.1759E-003 |
43 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.2694E-003 |
44 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 4.3218E-003 |
45 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 3.6829E-003 |
46 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 3.7225E-003 |
47 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.6024E-003 |
48 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 4.6280E-003 |
49 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.9798E-002 |
50 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.8511E-002 |
51 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 3.8510E-002 |
52 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.1822E-002 |
53 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 3.5212E-002 |
54 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.4806E-002 |
55 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 5.0870E-002 |
56 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.9083E-002 |
57 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 5.1117E-003 |
58 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 5.1770E-003 |
59 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.2680E-003 |
60 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 4.3194E-003 |
61 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 3.6802E-003 |
62 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 3.7124E-003 |
63 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.6026E-003 |
64 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 4.6282E-003 |
65 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 6.9903E-002 |
66 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 4.2080E-002 |
67 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 6.2578E-002 |
68 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 3.7273E-002 |
69 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 6.8289E-002 |
70 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 3.4832E-002 |
71 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 5.9724E-002 |
72 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 2.8145E-002 |
73 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 6.5804E-004 |
74 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 6.6650E-004 |
75 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 6.0294E-004 |
76 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 6.1241E-004 |
77 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 5.9426E-004 |
78 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 5.9746E-004 |
79 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 5.3719E-004 |
80 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 5.3807E-004 |
81 | Clear Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 0.1863 |
82 | Clear Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 0.1280 |
83 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 0.2114 |
84 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 0.1479 |
85 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 0.1300 |
86 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 6.6680E-002 |
87 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 5.7993E-002 |
88 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 2.7067E-002 |
89 | Clear Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 8.6550E-002 |
90 | Clear Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 5.0203E-002 |
91 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 8.4912E-002 |
92 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 4.8316E-002 |
93 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 8.0631E-002 |
94 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 4.0503E-002 |
95 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 5.8615E-002 |
96 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 2.7478E-002 |
97 | Clear Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 5.6515E-002 |
98 | Clear Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 3.6941E-002 |
99 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 4.4471E-002 |
100 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 2.9060E-002 |
101 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 4.1166E-002 |
102 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 2.1391E-002 |
103 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 5.7993E-002 |
104 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 2.7067E-002 |
105 | Clear Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 6.7543E-002 |
106 | Clear Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 4.0776E-002 |
107 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 6.0589E-002 |
108 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 3.6195E-002 |
109 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 6.6722E-002 |
110 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 3.3927E-002 |
111 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 5.8615E-002 |
112 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 2.7479E-002 |
113 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 0.1863 |
114 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 0.1280 |
115 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 0.2114 |
116 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 0.1479 |
117 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 0.1300 |
118 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 6.6672E-002 |
119 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 5.7987E-002 |
120 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 2.7064E-002 |
121 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 8.6549E-002 |
122 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 5.0199E-002 |
123 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 8.4911E-002 |
124 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 4.8312E-002 |
125 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 8.0627E-002 |
126 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 4.0499E-002 |
127 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 5.8609E-002 |
128 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 2.7475E-002 |
129 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 5.6517E-002 |
130 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 3.6939E-002 |
131 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 4.4472E-002 |
132 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 2.9059E-002 |
133 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 4.1163E-002 |
134 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 2.1389E-002 |
135 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 5.7987E-002 |
136 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 2.7064E-002 |
137 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 6.7543E-002 |
138 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 4.0774E-002 |
139 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 6.0589E-002 |
140 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 3.6192E-002 |
141 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 6.6718E-002 |
142 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 3.3923E-002 |
143 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 5.8610E-002 |
144 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 2.7475E-002 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | CORE_BOTTOM | Cooling | 37610.52745 | 37610.52745 | 3.09919 | 3.09919 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 21.56000 | 6.28881E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
2 | CORE_BOTTOM | Heating | 9406.53919 | 9406.53919 | 0.46107 | 0.46107 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:20:00 | -27.60000 | 3.41898E-004 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
3 | CORE_MID | Cooling | 30669.10117 | 30669.10117 | 2.52527 | 2.52527 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 21.56000 | 6.28881E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
4 | CORE_MID | Heating | 18329.01779 | 18329.01779 | 0.88954 | 0.88954 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -27.60000 | 3.41898E-004 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
5 | CORE_TOP | Cooling | 31756.81710 | 31756.81710 | 2.63822 | 2.63822 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 32.76000 | 6.30583E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
6 | CORE_TOP | Heating | 32648.96669 | 32648.96669 | 1.58938 | 1.58938 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -27.60000 | 3.41898E-004 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
7 | PERIMETER_TOP_ZN_3 | Cooling | 9776.87591 | 9776.87591 | 0.81219 | 0.81219 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | 33.08000 | 6.30633E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
8 | PERIMETER_TOP_ZN_3 | Heating | 14927.54466 | 14927.54466 | 0.72824 | 0.72824 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -27.60000 | 3.41898E-004 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
9 | PERIMETER_TOP_ZN_2 | Cooling | 11765.42229 | 11765.42229 | 0.97738 | 0.97738 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 09:30:00 | 25.96000 | 6.29539E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
10 | PERIMETER_TOP_ZN_2 | Heating | 9760.45422 | 9760.45422 | 0.47619 | 0.47619 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -27.60000 | 3.41898E-004 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
11 | PERIMETER_TOP_ZN_1 | Cooling | 15509.92602 | 15509.92602 | 1.28845 | 1.28845 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 33.26667 | 6.30663E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
12 | PERIMETER_TOP_ZN_1 | Heating | 15052.72465 | 15052.72465 | 0.73436 | 0.73436 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -27.60000 | 3.41898E-004 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
13 | PERIMETER_TOP_ZN_4 | Cooling | 13182.01199 | 13182.01199 | 1.09506 | 1.09506 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 30.36000 | 6.30211E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
14 | PERIMETER_TOP_ZN_4 | Heating | 9851.71542 | 9851.71542 | 0.48065 | 0.48065 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -27.60000 | 3.41898E-004 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
15 | PERIMETER_BOT_ZN_3 | Cooling | 7688.19239 | 7688.19239 | 0.63869 | 0.63869 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 33.40000 | 6.30683E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
16 | PERIMETER_BOT_ZN_3 | Heating | 11673.20177 | 11673.20177 | 0.56925 | 0.56925 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -27.60000 | 3.41898E-004 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
17 | PERIMETER_BOT_ZN_2 | Cooling | 9638.07607 | 9638.07607 | 0.80067 | 0.80067 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 09:50:00 | 26.86667 | 6.29676E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
18 | PERIMETER_BOT_ZN_2 | Heating | 7695.95577 | 7695.95577 | 0.37533 | 0.37533 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -27.60000 | 3.41898E-004 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
19 | PERIMETER_BOT_ZN_1 | Cooling | 12423.55612 | 12423.55612 | 1.03207 | 1.03207 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 33.40000 | 6.30683E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
20 | PERIMETER_BOT_ZN_1 | Heating | 11793.09216 | 11793.09216 | 0.57511 | 0.57511 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -27.60000 | 3.41898E-004 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
21 | PERIMETER_BOT_ZN_4 | Cooling | 10444.01386 | 10444.01386 | 0.86762 | 0.86762 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 28.36000 | 6.29904E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
22 | PERIMETER_BOT_ZN_4 | Heating | 7775.18876 | 7775.18876 | 0.37920 | 0.37920 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -27.60000 | 3.41898E-004 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
23 | PERIMETER_MID_ZN_3 | Cooling | 8558.42584 | 8558.42584 | 0.71098 | 0.71098 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 33.40000 | 6.30683E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
24 | PERIMETER_MID_ZN_3 | Heating | 11618.94942 | 11618.94942 | 0.56656 | 0.56656 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -27.60000 | 3.41898E-004 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
25 | PERIMETER_MID_ZN_2 | Cooling | 11658.00209 | 11658.00209 | 0.96846 | 0.96846 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 09:10:00 | 25.05333 | 6.29402E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
26 | PERIMETER_MID_ZN_2 | Heating | 7647.16996 | 7647.16996 | 0.37292 | 0.37292 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -27.60000 | 3.41898E-004 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
27 | PERIMETER_MID_ZN_1 | Cooling | 14248.30550 | 14248.30550 | 1.18365 | 1.18365 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 33.13333 | 6.30642E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
28 | PERIMETER_MID_ZN_1 | Heating | 11726.30793 | 11726.30793 | 0.57180 | 0.57180 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -27.60000 | 3.41898E-004 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
29 | PERIMETER_MID_ZN_4 | Cooling | 12249.02841 | 12249.02841 | 1.01756 | 1.01756 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 30.36000 | 6.30211E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
30 | PERIMETER_MID_ZN_4 | Heating | 7728.45876 | 7728.45876 | 0.37689 | 0.37689 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -27.60000 | 3.41898E-004 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PACU_VAV_BOT | Cooling | Sensible | 78792.77 | 5.65106 | 5.65106 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 00:00:00 |
2 | PACU_VAV_BOT | Heating | Sensible | 50730.26 | 2.34499 | 2.34499 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 |
3 | PACU_VAV_MID | Cooling | Sensible | 75018.36 | 5.34117 | 5.34117 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 00:00:00 |
4 | PACU_VAV_MID | Heating | Sensible | 50819.44 | 2.77771 | 2.77771 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:40:00 |
5 | PACU_VAV_TOP | Cooling | Sensible | 84034.61 | 6.12132 | 6.12132 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 00:00:00 |
6 | PACU_VAV_TOP | Heating | Sensible | 51088.12 | 4.00883 | 4.00883 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 03:50:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 3.09919 |
2 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.24182 |
3 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.26000 |
4 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.80579 |
5 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.64486 |
6 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
7 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.57554E-003 |
8 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.44369E-004 |
9 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.80579 |
10 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
11 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
12 | Coil:Heating:Water | CORE_BOTTOM VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 16502.30487 |
13 | Coil:Heating:Water | CORE_BOTTOM VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.44369E-004 |
14 | Coil:Heating:Water | CORE_BOTTOM VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 383.30597 |
15 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.52527 |
16 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.29678 |
17 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.31500 |
18 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.79546 |
19 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.79142 |
20 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
21 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.28377E-003 |
22 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.28879E-004 |
23 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.88954 |
24 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
25 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
26 | Coil:Heating:Water | CORE_MID VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 26162.28902 |
27 | Coil:Heating:Water | CORE_MID VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.28879E-004 |
28 | Coil:Heating:Water | CORE_MID VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 690.93627 |
29 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.63822 |
30 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.28408 |
31 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.31100 |
32 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.82049 |
33 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.75753 |
34 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
35 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.34119E-003 |
36 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 4.08071E-004 |
37 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.58938 |
38 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
39 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
40 | Coil:Heating:Water | CORE_TOP VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 46645.00621 |
41 | Coil:Heating:Water | CORE_TOP VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 4.08071E-004 |
42 | Coil:Heating:Water | CORE_TOP VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1230.66442 |
43 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.81219 |
44 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.19452 |
45 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.21300 |
46 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.17300 |
47 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.51873 |
48 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
49 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.95862E-003 |
50 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.86679E-004 |
51 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.72824 |
52 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
53 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
54 | Coil:Heating:Water | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 21338.52495 |
55 | Coil:Heating:Water | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.86679E-004 |
56 | Coil:Heating:Water | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 562.57895 |
57 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.97738 |
58 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.10234 |
59 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
60 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.19548 |
61 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.30000 |
62 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
63 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.72301E-003 |
64 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.22063E-004 |
65 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.47619 |
66 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
67 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
68 | Coil:Heating:Water | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 13952.50718 |
69 | Coil:Heating:Water | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.22063E-004 |
70 | Coil:Heating:Water | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 367.84367 |
71 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.28845 |
72 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.12262 |
73 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
74 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.25769 |
75 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.32699 |
76 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
77 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.10712E-003 |
78 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.88245E-004 |
79 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.73436 |
80 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
81 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
82 | Coil:Heating:Water | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 21517.57813 |
83 | Coil:Heating:Water | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.88245E-004 |
84 | Coil:Heating:Water | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 567.29694 |
85 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.09506 |
86 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 9.13332E-002 |
87 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
88 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.21901 |
89 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.30000 |
90 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
91 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 4.17154E-003 |
92 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.23205E-004 |
93 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.48065 |
94 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
95 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
96 | Coil:Heating:Water | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 14083.04368 |
97 | Coil:Heating:Water | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.23205E-004 |
98 | Coil:Heating:Water | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 371.28326 |
99 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.63869 |
100 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.24737 |
101 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.26600 |
102 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16989 |
103 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.65965 |
104 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
105 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.54021E-003 |
106 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.45967E-004 |
107 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.56925 |
108 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
109 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
110 | Coil:Heating:Water | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 16684.97035 |
111 | Coil:Heating:Water | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.45967E-004 |
112 | Coil:Heating:Water | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 439.95410 |
113 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.80067 |
114 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.12492 |
115 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
116 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16013 |
117 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.33313 |
118 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
119 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.04987E-003 |
120 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.62365E-005 |
121 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.37533 |
122 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
123 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
124 | Coil:Heating:Water | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 11000.42248 |
125 | Coil:Heating:Water | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.62365E-005 |
126 | Coil:Heating:Water | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 290.05398 |
127 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.03207 |
128 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.15308 |
129 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
130 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.20641 |
131 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.40822 |
132 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
133 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.48885E-003 |
134 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.47468E-004 |
135 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.57511 |
136 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
137 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
138 | Coil:Heating:Water | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 16856.46517 |
139 | Coil:Heating:Water | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.47468E-004 |
140 | Coil:Heating:Water | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 444.47286 |
141 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.86762 |
142 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.11528 |
143 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
144 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.17352 |
145 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.30740 |
146 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
147 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.30512E-003 |
148 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.72280E-005 |
149 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.37920 |
150 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
151 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
152 | Coil:Heating:Water | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 11113.75977 |
153 | Coil:Heating:Water | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.72280E-005 |
154 | Coil:Heating:Water | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 293.04031 |
155 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.71098 |
156 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.22222 |
157 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.23600 |
158 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16779 |
159 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.59258 |
160 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
161 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.71454E-003 |
162 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.45281E-004 |
163 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.56656 |
164 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
165 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
166 | Coil:Heating:Water | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 16606.49621 |
167 | Coil:Heating:Water | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.45281E-004 |
168 | Coil:Heating:Water | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 437.88931 |
169 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.96846 |
170 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.10328 |
171 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
172 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.19369 |
173 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.30000 |
174 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
175 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.68903E-003 |
176 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.56210E-005 |
177 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.37292 |
178 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
179 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
180 | Coil:Heating:Water | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 10930.06332 |
181 | Coil:Heating:Water | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.56210E-005 |
182 | Coil:Heating:Water | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 288.20179 |
183 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.18365 |
184 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.13348 |
185 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
186 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.23673 |
187 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.35594 |
188 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
189 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.85439E-003 |
190 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.46624E-004 |
191 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.57180 |
192 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
193 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
194 | Coil:Heating:Water | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 16760.06327 |
195 | Coil:Heating:Water | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.46624E-004 |
196 | Coil:Heating:Water | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 441.93568 |
197 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.01756 |
198 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 9.82895E-002 |
199 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
200 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.20351 |
201 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.30000 |
202 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
203 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.87631E-003 |
204 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.66382E-005 |
205 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.37689 |
206 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
207 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
208 | Coil:Heating:Water | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 11046.33933 |
209 | Coil:Heating:Water | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.66382E-005 |
210 | Coil:Heating:Water | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 291.26557 |
211 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 3.21912 |
212 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.51575 |
213 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Maximum Flow Rates [m3/s] | 6.43823 |
214 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Heating Design Air Flow Rate [m3/s] | 2.34499 |
215 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Cooling Design Air Flow Rate [m3/s] | 5.65106 |
216 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Main Design Air Flow Rate [m3/s] | 5.65106 |
217 | AirLoopHVAC | PACU_VAV_BOT | User Heating Air Flow Ratio [] | 0.30000 |
218 | AirLoopHVAC | PACU_VAV_BOT | Calculated Heating Air Flow Ratio [] | 0.41497 |
219 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 3.20296 |
220 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.59718 |
221 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Maximum Flow Rates [m3/s] | 6.40591 |
222 | AirLoopHVAC | PACU_VAV_MID | Adjusted Heating Design Air Flow Rate [m3/s] | 2.77771 |
223 | AirLoopHVAC | PACU_VAV_MID | Adjusted Cooling Design Air Flow Rate [m3/s] | 5.34117 |
224 | AirLoopHVAC | PACU_VAV_MID | Adjusted Main Design Air Flow Rate [m3/s] | 5.34117 |
225 | AirLoopHVAC | PACU_VAV_MID | User Heating Air Flow Ratio [] | 0.30000 |
226 | AirLoopHVAC | PACU_VAV_MID | Calculated Heating Air Flow Ratio [] | 0.52006 |
227 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 3.40565 |
228 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.66566 |
229 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Maximum Flow Rates [m3/s] | 6.81131 |
230 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Heating Design Air Flow Rate [m3/s] | 4.00883 |
231 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Cooling Design Air Flow Rate [m3/s] | 6.12132 |
232 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Main Design Air Flow Rate [m3/s] | 6.12132 |
233 | AirLoopHVAC | PACU_VAV_TOP | User Heating Air Flow Ratio [] | 0.30000 |
234 | AirLoopHVAC | PACU_VAV_TOP | Calculated Heating Air Flow Ratio [] | 0.65490 |
235 | AirLoopHVAC | PACU_VAV_BOT | Design Supply Air Flow Rate [m3/s] | 5.65106 |
236 | AirLoopHVAC | PACU_VAV_MID | Design Supply Air Flow Rate [m3/s] | 5.34117 |
237 | AirLoopHVAC | PACU_VAV_TOP | Design Supply Air Flow Rate [m3/s] | 6.12132 |
238 | Controller:OutdoorAir | PACU_VAV_BOT_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 5.65106 |
239 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 5.65106 |
240 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 93545.06964 |
241 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.80066 |
242 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 1.88350 |
243 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 31178.57171 |
244 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.80066 |
245 | Coil:Heating:Water | PACU_VAV_BOT HEATING COIL | Design Size Rated Capacity [W] | 47996.91054 |
246 | Coil:Heating:Water | PACU_VAV_BOT HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 4.19898E-004 |
247 | Coil:Heating:Water | PACU_VAV_BOT HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 747.59751 |
248 | Fan:VariableVolume | PACU_VAV_BOT FAN | Design Size Maximum Flow Rate [m3/s] | 5.65106 |
249 | Controller:WaterCoil | PACU_VAV_BOT_HEATC_CONTROLLER | Maximum Actuated Flow [m3/s] | 4.19898E-004 |
250 | Controller:OutdoorAir | PACU_VAV_MID_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 5.34117 |
251 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 5.34117 |
252 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 88415.29728 |
253 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.80066 |
254 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 1.78021 |
255 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 29468.81858 |
256 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.80066 |
257 | Coil:Heating:Water | PACU_VAV_MID HEATING COIL | Design Size Rated Capacity [W] | 49080.55344 |
258 | Coil:Heating:Water | PACU_VAV_MID HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 4.29378E-004 |
259 | Coil:Heating:Water | PACU_VAV_MID HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 753.20894 |
260 | Fan:VariableVolume | PACU_VAV_MID FAN | Design Size Maximum Flow Rate [m3/s] | 5.34117 |
261 | Controller:WaterCoil | PACU_VAV_MID_HEATC_CONTROLLER | Maximum Actuated Flow [m3/s] | 4.29378E-004 |
262 | Controller:OutdoorAir | PACU_VAV_TOP_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 6.12132 |
263 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 6.12132 |
264 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 101329.65116 |
265 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.80066 |
266 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 2.04024 |
267 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 33773.17273 |
268 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.80066 |
269 | Coil:Heating:Water | PACU_VAV_TOP HEATING COIL | Design Size Rated Capacity [W] | 49198.25196 |
270 | Coil:Heating:Water | PACU_VAV_TOP HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 4.30408E-004 |
271 | Coil:Heating:Water | PACU_VAV_TOP HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 771.37646 |
272 | Fan:VariableVolume | PACU_VAV_TOP FAN | Design Size Maximum Flow Rate [m3/s] | 6.12132 |
273 | Controller:WaterCoil | PACU_VAV_TOP_HEATC_CONTROLLER | Maximum Actuated Flow [m3/s] | 4.30408E-004 |
274 | PlantLoop | HEATSYS1 | Maximum Loop Flow Rate [m3/s] | 3.65226E-003 |
275 | PlantLoop | HEATSYS1 | Plant Loop Volume [m3] | 0.43827 |
276 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Flow Rate [m3/s] | 3.65226E-003 |
277 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Power Consumption [W] | 1099.89979 |
278 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Minimum Flow Rate [m3/s] | 0.00000 |
279 | Boiler:HotWater | HEATSYS1 BOILER | Design Size Nominal Capacity [W] | 417475.54988 |
280 | Boiler:HotWater | HEATSYS1 BOILER | User-Specified Nominal Capacity [W] | 417475.55000 |
281 | Boiler:HotWater | HEATSYS1 BOILER | Design Size Design Water Flow Rate [m3/s] | 3.65226E-003 |
282 | PlantLoop | SWHSYS1 | Maximum Loop Flow Rate [m3/s] | 5.36267E-005 |
283 | PlantLoop | SWHSYS1 | Plant Loop Volume [m3] | 6.43520E-003 |
284 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Flow Rate [m3/s] | 5.36267E-005 |
285 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Power Consumption [W] | 6.85023 |
286 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | Use Side Design Flow Rate [m3/s] | 5.36267E-005 |
Component Type | Name | Nominal Total Capacity {W} | |
1 | Coil:Heating:Water | CORE_BOTTOM VAV BOX REHEAT COIL | 15639.23 |
2 | Coil:Heating:Water | CORE_MID VAV BOX REHEAT COIL | 24800.07 |
3 | Coil:Heating:Water | CORE_TOP VAV BOX REHEAT COIL | 44208.15 |
4 | Coil:Heating:Water | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | 20220.99 |
5 | Coil:Heating:Water | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | 13221.74 |
6 | Coil:Heating:Water | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | 20390.64 |
7 | Coil:Heating:Water | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | 13345.43 |
8 | Coil:Heating:Water | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | 15811.58 |
9 | Coil:Heating:Water | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | 10424.54 |
10 | Coil:Heating:Water | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | 15974.07 |
11 | Coil:Heating:Water | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | 10531.93 |
12 | Coil:Heating:Water | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | 15737.24 |
13 | Coil:Heating:Water | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | 10357.88 |
14 | Coil:Heating:Water | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | 15882.75 |
15 | Coil:Heating:Water | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | 10468.06 |
16 | Coil:Heating:Water | PACU_VAV_BOT HEATING COIL | 32853.06 |
17 | Coil:Heating:Water | PACU_VAV_MID HEATING COIL | 32873.72 |
18 | Coil:Heating:Water | PACU_VAV_TOP HEATING COIL | 34181.92 |
DX Coil Type | DX Coil Name | Fan Type | Fan Name | Standard Net Cooling Capacity {W} | Standard Net Cooling Capacity {Btu/h} | IEER {Btu/W-h} | COP 100% Capacity {W/W} | COP 75% Capacity {W/W} | COP 50% Capacity {W/W} | COP 25% Capacity {W/W} | EER 100% Capacity {Btu/W-h} | EER 75% Capacity {Btu/W-h} | EER 50% Capacity {Btu/W-h} | EER 25% Capacity {Btu/W-h} | Supply Air Flow 100% {kg/s} | Supply Air Flow 75% {kg/s} | Supply Air Flow 50% {kg/s} | Supply Air Flow 25% {kg/s} | |
1 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | N/A | N/A | 91935.39 | 313696.58 | 11.87 | 3.01 | 3.40 | 3.58 | 3.76 | 10.26 | 11.60 | 12.22 | 12.82 | 5.7163 | 4.5199 | 3.0295 | 1.2756 |
2 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | N/A | N/A | 86893.89 | 296494.26 | 11.87 | 3.01 | 3.40 | 3.58 | 3.76 | 10.26 | 11.60 | 12.22 | 12.82 | 5.4029 | 4.2720 | 2.8634 | 1.2056 |
3 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | N/A | N/A | 99586.02 | 339801.61 | 11.87 | 3.01 | 3.40 | 3.58 | 3.76 | 10.26 | 11.60 | 12.22 | 12.82 | 6.1920 | 4.8960 | 3.2816 | 1.3817 |
Zone Name | # Surfaces | |
1 | CORE_BOTTOM | 7 |
2 | TOPFLOOR_PLENUM | 10 |
3 | MIDFLOOR_PLENUM | 14 |
4 | FIRSTFLOOR_PLENUM | 14 |
5 | CORE_MID | 7 |
6 | CORE_TOP | 7 |
7 | PERIMETER_TOP_ZN_3 | 8 |
8 | PERIMETER_TOP_ZN_2 | 8 |
9 | PERIMETER_TOP_ZN_1 | 8 |
10 | PERIMETER_TOP_ZN_4 | 8 |
11 | PERIMETER_BOT_ZN_3 | 12 |
12 | PERIMETER_BOT_ZN_2 | 10 |
13 | PERIMETER_BOT_ZN_1 | 12 |
14 | PERIMETER_BOT_ZN_4 | 10 |
15 | PERIMETER_MID_ZN_3 | 8 |
16 | PERIMETER_MID_ZN_2 | 8 |
17 | PERIMETER_MID_ZN_1 | 8 |
18 | PERIMETER_MID_ZN_4 | 8 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | CORE_BOT_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | CORE_BOT_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | CORE_BOT_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | CORE_BOT_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
5 | CORE_BOT_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | CORE_BOT_ZN_5_FLOOR_FFACTOR | 5.650E-003 | 5.642E-003 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_BOT_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
6 | CORE_BOT_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_BOT_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
7 | CORE_BOTTOM_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_BOTTOM_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
8 | PERIMETER_TOP_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 0.987 | 0.860 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
9 | PERIMETER_TOP_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 0.987 | 0.860 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | PERIMETER_TOP_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 0.987 | 0.860 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
11 | PERIMETER_TOP_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 0.987 | 0.860 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | iz-PERIMETER_TOP_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 225.00 | 180.00 | 6.47 | 40.76 | 0.00 | PERIMETER_TOP_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
13 | iz-PERIMETER_TOP_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 135.00 | 180.00 | 6.47 | 24.13 | 0.00 | PERIMETER_TOP_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
14 | iz-PERIMETER_TOP_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 45.00 | 180.00 | 6.47 | 40.76 | 0.00 | PERIMETER_TOP_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
15 | iz-PERIMETER_TOP_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 315.00 | 180.00 | 6.47 | 24.13 | 0.00 | PERIMETER_TOP_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
16 | iz-CORE_TOP_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 180.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_TOP_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
17 | BUILDING_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 1660.73 | 1660.73 | 1660.73 | 0.00 | 0.00 | 49.91 | 33.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
18 | PERIMETER_MID_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.746 | 0.671 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | PERIMETER_MID_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.746 | 0.671 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | PERIMETER_MID_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.746 | 0.671 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | PERIMETER_MID_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.746 | 0.671 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
22 | iz-PERIMETER_MID_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
23 | iz-PERIMETER_MID_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
24 | iz-PERIMETER_MID_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
25 | iz-PERIMETER_MID_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
26 | iz-CORE_MID_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_MID_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
27 | iz-PERIMETER_TOP_ZN_1_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_TOP_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
28 | iz-PERIMETER_TOP_ZN_2_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_TOP_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
29 | iz-PERIMETER_TOP_ZN_3_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_TOP_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
30 | iz-PERIMETER_TOP_ZN_4_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_TOP_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
31 | iz-CORE_TOP_ZN_5_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | CORE_TOP_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
32 | PERIMETER_BOT_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.760 | 0.682 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | PERIMETER_BOT_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.760 | 0.682 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
34 | PERIMETER_BOT_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.760 | 0.682 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | PERIMETER_BOT_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.760 | 0.682 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
36 | iz-PERIMETER_BOT_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_BOT_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
37 | iz-PERIMETER_BOT_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_BOT_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
38 | iz-PERIMETER_BOT_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_BOT_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
39 | iz-PERIMETER_BOT_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_BOT_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
40 | iz-CORE_BOT_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_BOT_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
41 | iz-PERIMETER_MID_ZN_1_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
42 | iz-PERIMETER_MID_ZN_2_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
43 | iz-PERIMETER_MID_ZN_3_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
44 | iz-PERIMETER_MID_ZN_4_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
45 | iz-CORE_MID_ZN_5_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | CORE_MID_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
46 | CORE_MID_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
47 | CORE_MID_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
48 | CORE_MID_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
49 | CORE_MID_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | CORE_MID_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | iz-CORE_MID_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
51 | CORE_MID_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_MID_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
52 | CORE_MID_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_MID_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
53 | CORE_TOP_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | CORE_TOP_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | CORE_TOP_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
56 | CORE_TOP_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | CORE_TOP_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | iz-CORE_TOP_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
58 | CORE_TOP_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 0.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_TOP_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
59 | CORE_TOP_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_TOP_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
60 | PERIMETER_TOP_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 0.987 | 0.860 | 71.65 | 136.92 | 71.65 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | Window | PERIMETER_TOP_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_NORTH_0.4 | N/A | 2.045 | No | 65.26 | 65.26 | 65.26 | 0.00 | 90.00 | 49.91 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
62 | PERIMETER_TOP_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
64 | iz-CORE_TOP_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | PERIMETER_TOP_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
66 | PERIMETER_TOP_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 225.00 | 0.00 | 6.47 | 49.91 | 0.00 | iz-PERIMETER_TOP_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
67 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
68 | PERIMETER_TOP_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 0.987 | 0.860 | 47.77 | 91.28 | 47.77 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | Window | PERIMETER_TOP_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_EAST_0.4 | N/A | 2.045 | No | 43.51 | 43.51 | 43.51 | 90.00 | 90.00 | 33.27 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | PERIMETER_TOP_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
71 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
72 | iz-CORE_TOP_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
73 | PERIMETER_TOP_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
74 | PERIMETER_TOP_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 315.00 | 0.00 | 6.47 | 33.27 | 0.00 | iz-PERIMETER_TOP_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
75 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
76 | PERIMETER_TOP_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 0.987 | 0.860 | 71.65 | 136.92 | 71.65 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
77 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | Window | PERIMETER_TOP_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_SOUTH_0.4 | N/A | 2.045 | No | 65.26 | 65.26 | 65.26 | 180.00 | 90.00 | 49.91 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
78 | PERIMETER_TOP_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
79 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | iz-CORE_TOP_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | PERIMETER_TOP_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
82 | PERIMETER_TOP_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 45.00 | 0.00 | 6.47 | 49.91 | 0.00 | iz-PERIMETER_TOP_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
83 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
84 | PERIMETER_TOP_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 0.987 | 0.860 | 47.77 | 91.28 | 47.77 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
85 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | Window | PERIMETER_TOP_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_WEST_0.4 | N/A | 2.045 | No | 43.51 | 43.51 | 43.51 | 270.00 | 90.00 | 33.27 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
86 | PERIMETER_TOP_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
88 | iz-CORE_TOP_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
89 | PERIMETER_TOP_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
90 | PERIMETER_TOP_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 135.00 | 0.00 | 6.47 | 33.27 | 0.00 | iz-PERIMETER_TOP_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
91 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
92 | PERIMETER_BOT_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.760 | 0.682 | 67.75 | 136.92 | 67.75 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
93 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_NORTH_0.4 | N/A | 2.045 | No | 21.75 | 21.75 | 21.75 | 0.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
94 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_NORTH_0.4 | N/A | 2.045 | No | 21.75 | 21.75 | 21.75 | 0.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
95 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_NORTH_0.4 | N/A | 2.045 | No | 21.75 | 21.75 | 21.75 | 0.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
96 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | Door | PERIMETER_BOT_ZN_3_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.065 | 3.065 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
97 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | Door | PERIMETER_BOT_ZN_3_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.065 | 3.065 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
98 | PERIMETER_BOT_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
99 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
100 | iz-CORE_BOT_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
101 | PERIMETER_BOT_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 0.220 | 0.209 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
102 | PERIMETER_BOT_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
103 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
104 | PERIMETER_BOT_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.760 | 0.682 | 45.82 | 91.28 | 45.82 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | Window | PERIMETER_BOT_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_EAST_0.4 | N/A | 2.045 | No | 41.85 | 41.85 | 41.85 | 90.00 | 90.00 | 30.84 | 1.36 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
106 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | Window | PERIMETER_BOT_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_EAST_0.4 | N/A | 2.045 | No | 1.65 | 1.65 | 1.65 | 90.00 | 90.00 | 1.22 | 1.36 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
107 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | Door | PERIMETER_BOT_ZN_2_WALL_EAST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.065 | 3.065 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
108 | PERIMETER_BOT_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
110 | iz-CORE_BOT_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
111 | PERIMETER_BOT_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 0.232 | 0.219 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
112 | PERIMETER_BOT_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
113 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
114 | PERIMETER_BOT_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.760 | 0.682 | 67.75 | 136.92 | 67.75 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
115 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_SOUTH_0.4 | N/A | 2.045 | No | 21.75 | 21.75 | 21.75 | 180.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
116 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_SOUTH_0.4 | N/A | 2.045 | No | 21.75 | 21.75 | 21.75 | 180.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
117 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_SOUTH_0.4 | N/A | 2.045 | No | 21.75 | 21.75 | 21.75 | 180.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
118 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | Door | PERIMETER_BOT_ZN_1_WALL_SOUTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.065 | 3.065 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
119 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | Door | PERIMETER_BOT_ZN_1_WALL_SOUTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.065 | 3.065 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
120 | PERIMETER_BOT_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
121 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
122 | iz-CORE_BOT_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
123 | PERIMETER_BOT_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 0.220 | 0.209 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
124 | PERIMETER_BOT_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
125 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
126 | PERIMETER_BOT_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.760 | 0.682 | 45.82 | 91.28 | 45.82 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
127 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | Window | PERIMETER_BOT_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_WEST_0.4 | N/A | 2.045 | No | 41.85 | 41.85 | 41.85 | 270.00 | 90.00 | 30.84 | 1.36 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
128 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | Window | PERIMETER_BOT_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_WEST_0.4 | N/A | 2.045 | No | 1.65 | 1.65 | 1.65 | 270.00 | 90.00 | 1.22 | 1.36 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
129 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | Door | PERIMETER_BOT_ZN_4_WALL_WEST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.065 | 3.065 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
130 | PERIMETER_BOT_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
131 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
132 | iz-CORE_BOT_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
133 | PERIMETER_BOT_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 0.232 | 0.219 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
134 | PERIMETER_BOT_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
135 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
136 | PERIMETER_MID_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.746 | 0.671 | 71.65 | 136.92 | 71.65 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
137 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | Window | PERIMETER_MID_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_NORTH_0.4 | N/A | 2.045 | No | 65.26 | 65.26 | 65.26 | 0.00 | 90.00 | 49.91 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
138 | PERIMETER_MID_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
139 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
140 | iz-CORE_MID_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
141 | PERIMETER_MID_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
142 | PERIMETER_MID_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
143 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
144 | PERIMETER_MID_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.746 | 0.671 | 47.77 | 91.28 | 47.77 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
145 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | Window | PERIMETER_MID_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_EAST_0.4 | N/A | 2.045 | No | 43.51 | 43.51 | 43.51 | 90.00 | 90.00 | 33.27 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
146 | PERIMETER_MID_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
147 | iz-PERIMETER_MID_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
148 | iz-CORE_MID_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
149 | PERIMETER_MID_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
150 | PERIMETER_MID_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
151 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
152 | PERIMETER_MID_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.746 | 0.671 | 71.65 | 136.92 | 71.65 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
153 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | Window | PERIMETER_MID_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_SOUTH_0.4 | N/A | 2.045 | No | 65.26 | 65.26 | 65.26 | 180.00 | 90.00 | 49.91 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
154 | PERIMETER_MID_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
155 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
156 | iz-CORE_MID_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
157 | PERIMETER_MID_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
158 | PERIMETER_MID_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
159 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
160 | PERIMETER_MID_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.746 | 0.671 | 47.77 | 91.28 | 47.77 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
161 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | Window | PERIMETER_MID_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.36_SHGC_WEST_0.4 | N/A | 2.045 | No | 43.51 | 43.51 | 43.51 | 270.00 | 90.00 | 33.27 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
162 | PERIMETER_MID_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
163 | iz-PERIMETER_MID_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
164 | iz-CORE_MID_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
165 | PERIMETER_MID_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
166 | PERIMETER_MID_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
167 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1Environment:Special Days |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | CORE_BOTTOM | RunPeriod: RUNPERIOD 1 | 8.2786712728E-003 | 6.2289533973E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
2 | TOPFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 0.1267697062 | 8.5206818216E-002 | Pass | Pass | 0.2183837296 | 0.4020675772 | Pass | Pass |
3 | MIDFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 1.5894671331E-002 | 1.1661330368E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
4 | FIRSTFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 1.3531853623E-002 | 9.6822838102E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
5 | CORE_MID | RunPeriod: RUNPERIOD 1 | 1.2036587668E-002 | 8.3884337302E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
6 | CORE_TOP | RunPeriod: RUNPERIOD 1 | 4.5160806725E-002 | 2.7086120397E-002 | Pass | Pass | 0.2362356438 | 0.4436026469 | Pass | Pass |
7 | PERIMETER_TOP_ZN_3 | RunPeriod: RUNPERIOD 1 | 0.1325444517 | 0.1797020133 | Pass | Pass | 8.2922295491 | 29.2436950432 | Pass | Pass |
8 | PERIMETER_TOP_ZN_2 | RunPeriod: RUNPERIOD 1 | 0.1156508845 | 0.1434725694 | Pass | Pass | 6.9605668177 | 26.9894589856 | Pass | Pass |
9 | PERIMETER_TOP_ZN_1 | RunPeriod: RUNPERIOD 1 | 0.1531989175 | 0.1422380635 | Pass | Pass | 9.7832679991 | 50.7541908126 | Pass | Pass |
10 | PERIMETER_TOP_ZN_4 | RunPeriod: RUNPERIOD 1 | 0.1443039439 | 0.1519849533 | Pass | Pass | 7.7353243357 | 27.8613850854 | Pass | Pass |
11 | PERIMETER_BOT_ZN_3 | RunPeriod: RUNPERIOD 1 | 1.9807567322E-002 | 1.7157029129E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
12 | PERIMETER_BOT_ZN_2 | RunPeriod: RUNPERIOD 1 | 4.1893159669E-002 | 6.6068975355E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
13 | PERIMETER_BOT_ZN_1 | RunPeriod: RUNPERIOD 1 | 9.7677499622E-002 | 9.9627918136E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
14 | PERIMETER_BOT_ZN_4 | RunPeriod: RUNPERIOD 1 | 4.3709673437E-002 | 4.4956348993E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
15 | PERIMETER_MID_ZN_3 | RunPeriod: RUNPERIOD 1 | 2.2916118352E-002 | 1.8373753627E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
16 | PERIMETER_MID_ZN_2 | RunPeriod: RUNPERIOD 1 | 5.3159711369E-002 | 7.8420444249E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
17 | PERIMETER_MID_ZN_1 | RunPeriod: RUNPERIOD 1 | 0.1313133539 | 0.1334857264 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
18 | PERIMETER_MID_ZN_4 | RunPeriod: RUNPERIOD 1 | 5.7121724833E-002 | 6.0105405991E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Heat Emission by ComponentsEnvelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
Heat Emissions [GJ] | 3594.25 | 110.91 | 0.00 | 2322.11 | 735.49 | 6762.76 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | -27.60 | 0.00 | -27.60 | Wetbulb [C] | 2.70 | 230.00 |
GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 33.40 | 16.00 | 16.30 | Wetbulb [C] | 4.90 | 240.00 |
Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
Jan | 0.00 | 0 | |||
Feb | 0.00 | 0 | |||
Mar | 0.00 | 0 | |||
Apr | 11.00 | 18 | |||
May | 24.00 | 14 | |||
Jun | 29.00 | 21 | |||
Jul | 6.00 | 9 | |||
Aug | 0.00 | 0 | |||
Sep | 0.00 | 0 | |||
Oct | 0.00 | 0 | |||
Nov | 0.00 | 0 | |||
Dec | 0.00 | 0 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
PERIMETER_TOP_PLENUM_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 0.860 | 0.987 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_TOP_PLENUM_WALL_EAST | NONRES_EXT_WALL_TOP | 0.30 | 0.860 | 0.987 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_TOP_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 0.860 | 0.987 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_TOP_PLENUM_WALL_WEST | NONRES_EXT_WALL_TOP | 0.30 | 0.860 | 0.987 | 40.57 | 40.57 | 270.00 | 90.00 | W |
BUILDING_ROOF | NONRES_ROOF | 0.30 | 0.182 | 0.186 | 1660.73 | 1660.73 | 0.00 | 0.00 | |
PERIMETER_MID_PLENUM_WALL_NORTH | NONRES_EXT_WALL_MID | 0.30 | 0.671 | 0.746 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_MID_PLENUM_WALL_EAST | NONRES_EXT_WALL_MID | 0.30 | 0.671 | 0.746 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_MID_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 0.671 | 0.746 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_MID_PLENUM_WALL_WEST | NONRES_EXT_WALL_MID | 0.30 | 0.671 | 0.746 | 40.57 | 40.57 | 270.00 | 90.00 | W |
PERIMETER_BOT_PLENUM_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.682 | 0.760 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_BOT_PLENUM_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.682 | 0.760 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_BOT_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.682 | 0.760 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_BOT_PLENUM_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.682 | 0.760 | 40.57 | 40.57 | 270.00 | 90.00 | W |
PERIMETER_TOP_ZN_3_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 0.860 | 0.987 | 136.92 | 71.65 | 0.00 | 90.00 | N |
PERIMETER_TOP_ZN_2_WALL_EAST | NONRES_EXT_WALL_TOP | 0.30 | 0.860 | 0.987 | 91.28 | 47.77 | 90.00 | 90.00 | E |
PERIMETER_TOP_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 0.860 | 0.987 | 136.92 | 71.65 | 180.00 | 90.00 | S |
PERIMETER_TOP_ZN_4_WALL_WEST | NONRES_EXT_WALL_TOP | 0.30 | 0.860 | 0.987 | 91.28 | 47.77 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_3_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.682 | 0.760 | 136.92 | 67.75 | 0.00 | 90.00 | N |
PERIMETER_BOT_ZN_3_FLOOR | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 1.00 | 0.212 | 0.220 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_BOT_ZN_2_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.682 | 0.760 | 91.28 | 45.82 | 90.00 | 90.00 | E |
PERIMETER_BOT_ZN_2_FLOOR | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 1.00 | 0.223 | 0.232 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_BOT_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.682 | 0.760 | 136.92 | 67.75 | 180.00 | 90.00 | S |
PERIMETER_BOT_ZN_1_FLOOR | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 1.00 | 0.212 | 0.220 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_BOT_ZN_4_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.682 | 0.760 | 91.28 | 45.82 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_4_FLOOR | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 1.00 | 0.223 | 0.232 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_MID_ZN_3_WALL_NORTH | NONRES_EXT_WALL_MID | 0.30 | 0.671 | 0.746 | 136.92 | 71.65 | 0.00 | 90.00 | N |
PERIMETER_MID_ZN_2_WALL_EAST | NONRES_EXT_WALL_MID | 0.30 | 0.671 | 0.746 | 91.28 | 47.77 | 90.00 | 90.00 | E |
PERIMETER_MID_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 0.671 | 0.746 | 136.92 | 71.65 | 180.00 | 90.00 | S |
PERIMETER_MID_ZN_4_WALL_WEST | NONRES_EXT_WALL_MID | 0.30 | 0.671 | 0.746 | 91.28 | 47.77 | 270.00 | 90.00 | W |
Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
CORE_BOT_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_BOT_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_BOT_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_BOT_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_BOT_ZN_5_FLOOR | CORE_BOT_ZN_5_FLOOR_FFACTOR | 1.00 | 0.006 | 0.006 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_BOT_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 225.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 135.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 45.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 315.00 | 180.00 | |
iz-CORE_TOP_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 180.00 | |
iz-PERIMETER_MID_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 180.00 | |
iz-PERIMETER_MID_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 90.00 | 180.00 | |
iz-PERIMETER_MID_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 180.00 | |
iz-PERIMETER_MID_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 270.00 | 180.00 | |
iz-CORE_MID_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_1_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_2_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 270.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_3_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_4_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 90.00 | 0.00 | |
iz-CORE_TOP_ZN_5_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 180.00 | 0.00 | |
iz-PERIMETER_BOT_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 90.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 270.00 | 180.00 | |
iz-CORE_BOT_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 180.00 | |
iz-PERIMETER_MID_ZN_1_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 0.00 | |
iz-PERIMETER_MID_ZN_2_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 270.00 | 0.00 | |
iz-PERIMETER_MID_ZN_3_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 0.00 | |
iz-PERIMETER_MID_ZN_4_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 90.00 | 0.00 | |
iz-CORE_MID_ZN_5_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 180.00 | 0.00 | |
CORE_MID_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_MID_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_MID_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_MID_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_MID_ZN_5_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_MID_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 0.00 | |
CORE_TOP_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_TOP_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_TOP_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_TOP_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_TOP_ZN_5_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_TOP_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 0.00 | |
PERIMETER_TOP_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_TOP_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_TOP_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_TOP_ZN_3_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_TOP_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 225.00 | 0.00 | |
PERIMETER_TOP_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_TOP_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_TOP_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_TOP_ZN_2_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_TOP_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 315.00 | 0.00 | |
PERIMETER_TOP_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_TOP_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_TOP_ZN_1_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_TOP_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 45.00 | 0.00 | |
PERIMETER_TOP_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_TOP_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_TOP_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_TOP_ZN_4_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_TOP_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 135.00 | 0.00 | |
PERIMETER_BOT_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_BOT_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_BOT_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_BOT_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 0.00 | |
PERIMETER_BOT_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_BOT_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_BOT_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 270.00 | 0.00 | |
PERIMETER_BOT_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_BOT_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_BOT_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 0.00 | |
PERIMETER_BOT_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_BOT_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_BOT_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_BOT_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 90.00 | 0.00 | |
PERIMETER_MID_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_MID_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_MID_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_MID_ZN_3_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_MID_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 0.00 | |
PERIMETER_MID_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_MID_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_MID_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_MID_ZN_2_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_MID_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 270.00 | 0.00 | |
PERIMETER_MID_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_MID_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_MID_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_MID_ZN_1_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_MID_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 0.00 | |
PERIMETER_MID_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_MID_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_MID_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_MID_ZN_4_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_MID_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 90.00 | 0.00 | |
CORE_BOTTOM_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
CORE_MID_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
CORE_TOP_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N |
Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | WINDOW_U_0.36_SHGC_NORTH_0.4 | 65.26 | 0.00 | 0.00 | 65.26 | 65.26 | 2.045 | 0.401 | 0.442 | No | PERIMETER_TOP_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | WINDOW_U_0.36_SHGC_EAST_0.4 | 43.51 | 0.00 | 0.00 | 43.51 | 43.51 | 2.045 | 0.401 | 0.442 | No | PERIMETER_TOP_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | WINDOW_U_0.36_SHGC_SOUTH_0.4 | 65.26 | 0.00 | 0.00 | 65.26 | 65.26 | 2.045 | 0.401 | 0.442 | No | PERIMETER_TOP_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | WINDOW_U_0.36_SHGC_WEST_0.4 | 43.51 | 0.00 | 0.00 | 43.51 | 43.51 | 2.045 | 0.401 | 0.442 | No | PERIMETER_TOP_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | WINDOW_U_0.36_SHGC_NORTH_0.4 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.045 | 0.401 | 0.442 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | WINDOW_U_0.36_SHGC_NORTH_0.4 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.045 | 0.401 | 0.442 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | WINDOW_U_0.36_SHGC_NORTH_0.4 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.045 | 0.401 | 0.442 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | WINDOW_U_0.36_SHGC_EAST_0.4 | 41.85 | 0.00 | 0.00 | 41.85 | 41.85 | 2.045 | 0.401 | 0.442 | No | PERIMETER_BOT_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | WINDOW_U_0.36_SHGC_EAST_0.4 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.045 | 0.401 | 0.442 | No | PERIMETER_BOT_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | WINDOW_U_0.36_SHGC_SOUTH_0.4 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.045 | 0.401 | 0.442 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | WINDOW_U_0.36_SHGC_SOUTH_0.4 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.045 | 0.401 | 0.442 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | WINDOW_U_0.36_SHGC_SOUTH_0.4 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.045 | 0.401 | 0.442 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | WINDOW_U_0.36_SHGC_WEST_0.4 | 41.85 | 0.00 | 0.00 | 41.85 | 41.85 | 2.045 | 0.401 | 0.442 | No | PERIMETER_BOT_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | WINDOW_U_0.36_SHGC_WEST_0.4 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.045 | 0.401 | 0.442 | No | PERIMETER_BOT_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | WINDOW_U_0.36_SHGC_NORTH_0.4 | 65.26 | 0.00 | 0.00 | 65.26 | 65.26 | 2.045 | 0.401 | 0.442 | No | PERIMETER_MID_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | WINDOW_U_0.36_SHGC_EAST_0.4 | 43.51 | 0.00 | 0.00 | 43.51 | 43.51 | 2.045 | 0.401 | 0.442 | No | PERIMETER_MID_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | WINDOW_U_0.36_SHGC_SOUTH_0.4 | 65.26 | 0.00 | 0.00 | 65.26 | 65.26 | 2.045 | 0.401 | 0.442 | No | PERIMETER_MID_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | WINDOW_U_0.36_SHGC_WEST_0.4 | 43.51 | 0.00 | 0.00 | 43.51 | 43.51 | 2.045 | 0.401 | 0.442 | No | PERIMETER_MID_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
Total or Average | 652.62 | 2.045 | 0.401 | 0.442 | |||||||||||||||||
North Total or Average | 195.79 | 2.045 | 0.401 | 0.442 | |||||||||||||||||
Non-North Total or Average | 456.84 | 2.045 | 0.401 | 0.442 |
Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
None |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 2.101 | 3.065 | 1.95 | PERIMETER_BOT_ZN_3_WALL_NORTH |
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 2.101 | 3.065 | 1.95 | PERIMETER_BOT_ZN_3_WALL_NORTH |
PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | SWINGING DOOR_CON | 2.101 | 3.065 | 1.95 | PERIMETER_BOT_ZN_2_WALL_EAST |
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | SWINGING DOOR_CON | 2.101 | 3.065 | 1.95 | PERIMETER_BOT_ZN_1_WALL_SOUTH |
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | SWINGING DOOR_CON | 2.101 | 3.065 | 1.95 | PERIMETER_BOT_ZN_1_WALL_SOUTH |
PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | SWINGING DOOR_CON | 2.101 | 3.065 | 1.95 | PERIMETER_BOT_ZN_4_WALL_WEST |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Interior LightingZone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
CORE_BOTTOM_LIGHTS | CORE_BOTTOM | CORE_BOTTOM | GENERAL | 8.6994 | 983.54 | 8556.15 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 44.78 | 0.0000 | Y | 71.93 |
CORE_MID_LIGHTS | CORE_MID | CORE_MID | GENERAL | 8.6994 | 983.54 | 8556.15 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 44.78 | 0.0000 | Y | 71.93 |
CORE_TOP_LIGHTS | CORE_TOP | CORE_TOP | GENERAL | 8.6994 | 983.54 | 8556.15 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 44.78 | 0.0000 | Y | 71.93 |
PERIMETER_TOP_ZN_3_LIGHTS | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3 | GENERAL | 8.6994 | 207.34 | 1803.71 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 26.32 | 0.0000 | Y | 8.91 |
PERIMETER_TOP_ZN_2_LIGHTS | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2 | GENERAL | 8.6994 | 131.26 | 1141.90 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.88 | 0.0000 | Y | 5.55 |
PERIMETER_TOP_ZN_1_LIGHTS | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1 | GENERAL | 8.6994 | 207.34 | 1803.71 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.59 | 0.0000 | Y | 8.67 |
PERIMETER_TOP_ZN_4_LIGHTS | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4 | GENERAL | 8.6994 | 131.25 | 1141.82 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.98 | 0.0000 | Y | 5.57 |
PERIMETER_BOT_ZN_3_LIGHTS | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3 | GENERAL | 8.6994 | 207.34 | 1803.71 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 26.22 | 0.0000 | Y | 8.88 |
PERIMETER_BOT_ZN_2_LIGHTS | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2 | GENERAL | 8.6994 | 131.26 | 1141.90 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.82 | 0.0000 | Y | 5.53 |
PERIMETER_BOT_ZN_1_LIGHTS | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1 | GENERAL | 8.6994 | 207.34 | 1803.71 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.54 | 0.0000 | Y | 8.65 |
PERIMETER_BOT_ZN_4_LIGHTS | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4 | GENERAL | 8.6994 | 131.25 | 1141.82 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.91 | 0.0000 | Y | 5.55 |
PERIMETER_MID_ZN_3_LIGHTS | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3 | GENERAL | 8.6994 | 207.34 | 1803.71 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 26.32 | 0.0000 | Y | 8.91 |
PERIMETER_MID_ZN_2_LIGHTS | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2 | GENERAL | 8.6994 | 131.26 | 1141.90 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.88 | 0.0000 | Y | 5.55 |
PERIMETER_MID_ZN_1_LIGHTS | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1 | GENERAL | 8.6994 | 207.34 | 1803.71 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.59 | 0.0000 | Y | 8.67 |
PERIMETER_MID_ZN_4_LIGHTS | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4 | GENERAL | 8.6994 | 131.25 | 1141.82 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.98 | 0.0000 | Y | 5.57 |
Interior Lighting Total | 8.6994 | 4982.19 | 43341.88 | 301.78 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
PERIMETER_BOT_ZN_1_DAYLREFPT1 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1803.71 | 691.72 |
PERIMETER_BOT_ZN_1_DAYLREFPT2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1803.71 | 251.62 |
PERIMETER_BOT_ZN_2_DAYLREFPT1 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1141.90 | 437.92 |
PERIMETER_BOT_ZN_2_DAYLREFPT2 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1141.90 | 159.29 |
PERIMETER_BOT_ZN_3_DAYLREFPT1 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1803.71 | 691.72 |
PERIMETER_BOT_ZN_3_DAYLREFPT2 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1803.71 | 251.62 |
PERIMETER_BOT_ZN_4_DAYLREFPT1 | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1141.82 | 437.89 |
PERIMETER_BOT_ZN_4_DAYLREFPT2 | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1141.82 | 159.28 |
PERIMETER_MID_ZN_1_DAYLREFPT1 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1803.71 | 691.72 |
PERIMETER_MID_ZN_1_DAYLREFPT2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1803.71 | 251.62 |
PERIMETER_MID_ZN_2_DAYLREFPT1 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1141.90 | 437.92 |
PERIMETER_MID_ZN_2_DAYLREFPT2 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1141.90 | 159.29 |
PERIMETER_MID_ZN_3_DAYLREFPT1 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1803.71 | 691.72 |
PERIMETER_MID_ZN_3_DAYLREFPT2 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1803.71 | 251.62 |
PERIMETER_MID_ZN_4_DAYLREFPT1 | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1141.82 | 437.89 |
PERIMETER_MID_ZN_4_DAYLREFPT2 | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1141.82 | 159.28 |
PERIMETER_TOP_ZN_1_DAYLREFPT1 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1803.71 | 691.72 |
PERIMETER_TOP_ZN_1_DAYLREFPT2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1803.71 | 251.62 |
PERIMETER_TOP_ZN_2_DAYLREFPT1 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1141.90 | 437.92 |
PERIMETER_TOP_ZN_2_DAYLREFPT2 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1141.90 | 159.29 |
PERIMETER_TOP_ZN_3_DAYLREFPT1 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1803.71 | 691.72 |
PERIMETER_TOP_ZN_3_DAYLREFPT2 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1803.71 | 251.62 |
PERIMETER_TOP_ZN_4_DAYLREFPT1 | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1141.82 | 437.89 |
PERIMETER_TOP_ZN_4_DAYLREFPT2 | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1141.82 | 159.28 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 563.81 | AstronomicalClock | - | 42.11 | 42.11 | 4.46 | |
EXTERIOR_LIGHTS_B | 407.66 | AstronomicalClock | - | 83.57 | 62.84 | 4.81 | |
EXTERIOR_LIGHTS_C | 4714.72 | AstronomicalClock | - | 83.57 | 48.07 | 42.54 | |
Exterior Lighting Total | 5686.19 | 51.81 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Central PlantType | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
HEATSYS1 BOILER | Boiler:HotWater | 417475.55 | 0.80 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | 93545.07 | 74897.35 | 18647.72 | 0.80 | 3.70 | |||
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | 88415.30 | 70790.17 | 17625.12 | 0.80 | 3.70 | |||
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | 101329.65 | 81130.12 | 20199.53 | 0.80 | 3.70 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
PACU_VAV_BOT COOLING COIL | 91935.4 | 3.01 | 10.26 | N/A | N/A | 11.87 | |
PACU_VAV_MID COOLING COIL | 86893.9 | 3.01 | 10.26 | N/A | N/A | 11.87 | |
PACU_VAV_TOP COOLING COIL | 99586.0 | 3.01 | 10.26 | N/A | N/A | 11.87 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | ||||||||
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | ||||||||
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | Coil:Heating:Water | 16502.30 | 15639.23 | - |
CORE_MID VAV BOX REHEAT COIL | Coil:Heating:Water | 26162.29 | 24800.07 | - |
CORE_TOP VAV BOX REHEAT COIL | Coil:Heating:Water | 46645.01 | 44208.15 | - |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Water | 21338.52 | 20220.99 | - |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Water | 13952.51 | 13221.74 | - |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 21517.58 | 20390.64 | - |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Water | 14083.04 | 13345.43 | - |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Water | 16684.97 | 15811.58 | - |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Water | 11000.42 | 10424.54 | - |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 16856.47 | 15974.07 | - |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Water | 11113.76 | 10531.93 | - |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Water | 16606.50 | 15737.24 | - |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Water | 10930.06 | 10357.88 | - |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 16760.06 | 15882.75 | - |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Water | 11046.34 | 10468.06 | - |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Water | 47996.91 | 32853.06 | - |
PACU_VAV_MID HEATING COIL | Coil:Heating:Water | 49080.55 | 32873.72 | - |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Water | 49198.25 | 34181.92 | - |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
PACU_VAV_BOT FAN | Fan:VariableVolume | 0.60 | 1389.42 | 5.65 | 12988.74 | 2298.46 | 1.00 | 1.13 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 |
PACU_VAV_MID FAN | Fan:VariableVolume | 0.60 | 1389.42 | 5.34 | 12276.47 | 2298.46 | 1.00 | 1.13 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 |
PACU_VAV_TOP FAN | Fan:VariableVolume | 0.60 | 1389.42 | 6.12 | 14069.63 | 2298.46 | 1.00 | 1.12 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
HEATSYS1 PUMP | Pump:VariableSpeed | Intermittent | 180705.70 | 0.003652 | 1099.90 | 301156.09 | 0.90 | General |
SWHSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.000054 | 6.85 | 127739.32 | 0.30 | General |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SWHSYS1 WATER HEATER | WaterHeater:Mixed | 0.38 | 29307.11 | 1.00 | 27.19 | 0.85 |
DX Cooling Coil Type | Assocated Fan | Net Cooling Capacity [W] | COP [W/W] | EER [Btu/W-h] | IEER [Btu/W-h] | Supply Air Flow 100% [kg/s] | COP 75% Capacity [W/W] | EER 75% Capacity [Btu/W-h] | Supply Air Flow 75% [kg/s] | COP 50% Capacity [W/W] | EER 50% Capacity [Btu/W-h] | Supply Air Flow 50% [kg/s] | COP 25% Capacity [W/W] | EER 25% Capacity [Btu/W-h] | Supply Air Flow 25% [kg/s] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 91935.39 | 3.01 | 10.26 | 11.87 | 5.7163 | 3.40 | 11.60 | 4.5199 | 3.58 | 12.22 | 3.0295 | 3.76 | 12.82 | 1.2756 |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 86893.89 | 3.01 | 10.26 | 11.87 | 5.4029 | 3.40 | 11.60 | 4.2720 | 3.58 | 12.22 | 2.8634 | 3.76 | 12.82 | 1.2056 |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 99586.02 | 3.01 | 10.26 | 11.87 | 6.1920 | 3.40 | 11.60 | 4.8960 | 3.58 | 12.22 | 3.2816 | 3.76 | 12.82 | 1.3817 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
CORE_BOTTOM | 37610.53 | 37610.53 | 38.24 | 3.099 | 3.099 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 24.00 | 24.00 | 0.00882 | 21.56 | 0.00629 | 0.425 | 0.00 |
CORE_MID | 30669.10 | 30669.10 | 31.18 | 2.525 | 2.525 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 24.00 | 24.00 | 0.00890 | 21.56 | 0.00629 | 0.425 | 0.00 |
CORE_TOP | 31756.82 | 31756.82 | 32.29 | 2.638 | 2.638 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 24.00 | 24.00 | 0.00888 | 32.76 | 0.00631 | 0.425 | 0.00 |
PERIMETER_TOP_ZN_3 | 9776.88 | 9776.88 | 47.15 | 0.812 | 0.812 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | 24.00 | 24.00 | 0.00871 | 33.08 | 0.00631 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_2 | 11765.42 | 11765.42 | 89.63 | 0.977 | 0.977 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 09:30:00 | 24.00 | 24.00 | 0.00861 | 25.96 | 0.00630 | 0.057 | 0.00 |
PERIMETER_TOP_ZN_1 | 15509.93 | 15509.93 | 74.80 | 1.288 | 1.288 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 24.00 | 24.00 | 0.00863 | 33.27 | 0.00631 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_4 | 13182.01 | 13182.01 | 100.43 | 1.095 | 1.095 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 24.00 | 24.00 | 0.00860 | 30.36 | 0.00630 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_3 | 7688.19 | 7688.19 | 37.08 | 0.639 | 0.639 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 24.00 | 24.00 | 0.00880 | 33.40 | 0.00631 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_2 | 9638.08 | 9638.08 | 73.43 | 0.801 | 0.801 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 09:50:00 | 24.00 | 24.00 | 0.00865 | 26.87 | 0.00630 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_1 | 12423.56 | 12423.56 | 59.92 | 1.032 | 1.032 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 24.00 | 24.00 | 0.00868 | 33.40 | 0.00631 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_4 | 10444.01 | 10444.01 | 79.57 | 0.868 | 0.868 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 24.00 | 24.00 | 0.00864 | 28.36 | 0.00630 | 0.057 | 0.00 |
PERIMETER_MID_ZN_3 | 8558.43 | 8558.43 | 41.28 | 0.711 | 0.711 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 24.00 | 24.00 | 0.00875 | 33.40 | 0.00631 | 0.090 | 0.00 |
PERIMETER_MID_ZN_2 | 11658.00 | 11658.00 | 88.81 | 0.968 | 0.968 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 09:10:00 | 24.00 | 24.00 | 0.00862 | 25.05 | 0.00629 | 0.057 | 0.00 |
PERIMETER_MID_ZN_1 | 14248.31 | 14248.31 | 68.72 | 1.184 | 1.184 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 24.00 | 24.00 | 0.00865 | 33.13 | 0.00631 | 0.090 | 0.00 |
PERIMETER_MID_ZN_4 | 12249.03 | 12249.03 | 93.32 | 1.018 | 1.018 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 24.00 | 24.00 | 0.00861 | 30.36 | 0.00630 | 0.057 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
CORE_BOTTOM | 9406.54 | 9406.54 | 9.56 | 0.461 | 0.461 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:20:00 | 21.00 | 21.00 | 0.00800 | -27.60 | 0.00034 | 0.425 | 0.00 |
CORE_MID | 18329.02 | 18329.02 | 18.64 | 0.890 | 0.890 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00800 | -27.60 | 0.00034 | 0.425 | 0.00 |
CORE_TOP | 32648.97 | 32648.97 | 33.20 | 1.589 | 1.589 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00800 | -27.60 | 0.00034 | 0.425 | 0.00 |
PERIMETER_TOP_ZN_3 | 14927.54 | 14927.54 | 72.00 | 0.728 | 0.728 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00788 | -27.60 | 0.00034 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_2 | 9760.45 | 9760.45 | 74.36 | 0.476 | 0.476 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00788 | -27.60 | 0.00034 | 0.057 | 0.00 |
PERIMETER_TOP_ZN_1 | 15052.72 | 15052.72 | 72.60 | 0.734 | 0.734 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00788 | -27.60 | 0.00034 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_4 | 9851.72 | 9851.72 | 75.06 | 0.481 | 0.481 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00788 | -27.60 | 0.00034 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_3 | 11673.20 | 11673.20 | 56.30 | 0.569 | 0.569 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00792 | -27.60 | 0.00034 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_2 | 7695.96 | 7695.96 | 58.63 | 0.375 | 0.375 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00792 | -27.60 | 0.00034 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_1 | 11793.09 | 11793.09 | 56.88 | 0.575 | 0.575 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00792 | -27.60 | 0.00034 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_4 | 7775.19 | 7775.19 | 59.24 | 0.379 | 0.379 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00792 | -27.60 | 0.00034 | 0.057 | 0.00 |
PERIMETER_MID_ZN_3 | 11618.95 | 11618.95 | 56.04 | 0.567 | 0.567 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00787 | -27.60 | 0.00034 | 0.090 | 0.00 |
PERIMETER_MID_ZN_2 | 7647.17 | 7647.17 | 58.26 | 0.373 | 0.373 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00787 | -27.60 | 0.00034 | 0.057 | 0.00 |
PERIMETER_MID_ZN_1 | 11726.31 | 11726.31 | 56.56 | 0.572 | 0.572 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00788 | -27.60 | 0.00034 | 0.090 | 0.00 |
PERIMETER_MID_ZN_4 | 7728.46 | 7728.46 | 58.88 | 0.377 | 0.377 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00787 | -27.60 | 0.00034 | 0.057 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PACU_VAV_BOT | 5.65 | 5.65 | 2.34 | 2.34 | 5.6511 | 2.3450 | 5.6511 | 0.4150 | 0.3000 |
PACU_VAV_MID | 5.34 | 5.34 | 2.78 | 2.78 | 5.3412 | 2.7777 | 5.3412 | 0.5201 | 0.3000 |
PACU_VAV_TOP | 6.12 | 6.12 | 4.01 | 4.01 | 6.1213 | 4.0088 | 6.1213 | 0.6549 | 0.3000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_BOTTOM VAV BOX | 16502.305 | 16502.305 | 0.805790 | 0.00014437 | 383.306 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:20:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:20:00 | 16502.30 | 16502.30 | 0.805790 | 12.80 | 10.41 | 0.00800000 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 0.0000 | 21.00 | 0.00800000 | 45.2310 | 9406.54 | 0.00 | 16556.75 | 16556.75 |
CORE_MID VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_MID VAV BOX | 26162.289 | 26162.289 | 0.889541 | 0.00022888 | 690.936 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 26162.29 | 26162.29 | 0.889541 | 12.80 | 10.41 | 0.00800000 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 0.0000 | 21.00 | 0.00800000 | 45.2310 | 18329.02 | 0.00 | 26255.08 | 26255.08 |
CORE_TOP VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_TOP VAV BOX | 46645.006 | 46645.006 | 1.589381 | 0.00040807 | 1230.664 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 46645.01 | 46645.01 | 1.589381 | 12.80 | 10.41 | 0.00800000 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 0.0000 | 21.00 | 0.00800000 | 45.2310 | 32648.97 | 0.00 | 46801.73 | 46801.73 |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_3 VAV BOX | 21338.525 | 21338.525 | 0.728244 | 0.00018668 | 562.579 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21338.52 | 21338.52 | 0.728244 | 12.80 | 10.41 | 0.00800000 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 0.0000 | 21.00 | 0.00788346 | 44.5822 | 14927.54 | 0.00 | 21407.28 | 21407.28 |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_2 VAV BOX | 13952.507 | 13952.507 | 0.476192 | 0.00012206 | 367.844 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 13952.51 | 13952.51 | 0.476192 | 12.80 | 10.41 | 0.00800000 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 0.0000 | 21.00 | 0.00788124 | 44.5699 | 9760.45 | 0.00 | 13997.41 | 13997.41 |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_1 VAV BOX | 21517.578 | 21517.578 | 0.734362 | 0.00018825 | 567.297 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21517.58 | 21517.58 | 0.734362 | 12.80 | 10.41 | 0.00800000 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 0.0000 | 21.00 | 0.00788443 | 44.5876 | 15052.72 | 0.00 | 21586.89 | 21586.89 |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_4 VAV BOX | 14083.044 | 14083.044 | 0.480653 | 0.00012320 | 371.283 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 14083.04 | 14083.04 | 0.480653 | 12.80 | 10.41 | 0.00800000 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 0.0000 | 21.00 | 0.00788233 | 44.5760 | 9851.72 | 0.00 | 14128.36 | 14128.36 |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_3 VAV BOX | 16684.970 | 16684.970 | 0.569246 | 0.00014597 | 439.954 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 16684.97 | 16684.97 | 0.569246 | 12.80 | 10.41 | 0.00800000 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 0.0000 | 21.00 | 0.00791875 | 44.7785 | 11673.20 | 0.00 | 16739.19 | 16739.19 |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_2 VAV BOX | 11000.422 | 11000.422 | 0.375328 | 0.00009624 | 290.054 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 11000.42 | 11000.42 | 0.375328 | 12.80 | 10.41 | 0.00800000 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 0.0000 | 21.00 | 0.00791838 | 44.7765 | 7695.96 | 0.00 | 11036.11 | 11036.11 |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_1 VAV BOX | 16856.465 | 16856.465 | 0.575107 | 0.00014747 | 444.473 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 16856.47 | 16856.47 | 0.575107 | 12.80 | 10.41 | 0.00800000 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 0.0000 | 21.00 | 0.00791972 | 44.7839 | 11793.09 | 0.00 | 16911.22 | 16911.22 |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_4 VAV BOX | 11113.760 | 11113.760 | 0.379201 | 0.00009723 | 293.040 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 11113.76 | 11113.76 | 0.379201 | 12.80 | 10.41 | 0.00800000 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 0.0000 | 21.00 | 0.00791932 | 44.7817 | 7775.19 | 0.00 | 11149.80 | 11149.80 |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_3 VAV BOX | 16606.496 | 16606.496 | 0.566556 | 0.00014528 | 437.889 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 16606.50 | 16606.50 | 0.566556 | 12.80 | 10.41 | 0.00800000 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 0.0000 | 21.00 | 0.00787375 | 44.5278 | 11618.95 | 0.00 | 16660.49 | 16660.49 |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_2 VAV BOX | 10930.063 | 10930.063 | 0.372919 | 0.00009562 | 288.202 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 10930.06 | 10930.06 | 0.372919 | 12.80 | 10.41 | 0.00800000 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 0.0000 | 21.00 | 0.00787266 | 44.5218 | 7647.17 | 0.00 | 10965.54 | 10965.54 |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_1 VAV BOX | 16760.063 | 16760.063 | 0.571804 | 0.00014662 | 441.936 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 16760.06 | 16760.06 | 0.571804 | 12.80 | 10.41 | 0.00800000 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 0.0000 | 21.00 | 0.00787503 | 44.5350 | 11726.31 | 0.00 | 16814.54 | 16814.54 |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_4 VAV BOX | 11046.339 | 11046.339 | 0.376893 | 0.00009664 | 291.266 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 11046.34 | 11046.34 | 0.376893 | 12.80 | 10.41 | 0.00800000 | 40.00 | 19.63 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 0.0000 | 21.00 | 0.00787410 | 44.5298 | 7728.46 | 0.00 | 11082.18 | 11082.18 |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_BOT | 93545.070 | 74897.352 | 5.651058 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | 91437.06 | 91437.06 | 5.651058 | 25.99 | 15.50 | 0.00826090 | 10.66 | 9.79 | 0.00826090 | 33.40 | 0.00630683 | 16.37 | 21.1495 | 24.00 | 0.00878571 | 41.3468 | 67952.95 | 0.00 | 96457.52 | 71070.07 |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Water | AirLoopHVAC | PACU_VAV_BOT | 47996.911 | 47996.911 | 1.695317 | 0.00041990 | 747.598 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 47996.91 | 47996.91 | 1.695317 | -13.95 | -13.95 | 0.00255519 | 12.80 | 10.41 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 70.4983 | 18.18 | 0.00784947 | 52.8848 | 20159.43 | 0.00 | 39715.96 | 39715.96 |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_MID | 88415.297 | 70790.173 | 5.341168 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 86422.89 | 86422.89 | 5.341168 | 26.11 | 15.52 | 0.00823724 | 10.66 | 9.77 | 0.00823724 | 33.40 | 0.00630683 | 16.37 | 22.3766 | 24.00 | 0.00879568 | 41.3929 | 64119.33 | 0.00 | 91168.04 | 67172.77 |
PACU_VAV_MID HEATING COIL | Coil:Heating:Water | AirLoopHVAC | PACU_VAV_MID | 49080.553 | 49080.553 | 1.602350 | 0.00042938 | 753.209 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:40:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 49080.55 | 49080.55 | 1.602350 | -16.14 | -16.14 | 0.00222936 | 12.80 | 10.41 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 74.5886 | 17.60 | 0.00765130 | 53.4967 | 19423.89 | 0.00 | 39759.71 | 39759.71 |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_TOP | 101329.651 | 81130.118 | 6.121324 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 99046.22 | 99046.22 | 6.121324 | 25.84 | 15.46 | 0.00827473 | 10.66 | 9.81 | 0.00827473 | 33.40 | 0.00630683 | 16.37 | 19.5247 | 24.00 | 0.00875549 | 41.2063 | 73277.23 | 0.00 | 104484.47 | 76984.34 |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Water | AirLoopHVAC | PACU_VAV_TOP | 49198.252 | 49198.252 | 1.836397 | 0.00043041 | 771.376 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 03:50:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 49198.25 | 49198.25 | 1.836397 | -12.52 | -12.52 | 0.00293518 | 12.80 | 10.41 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 65.0823 | 15.60 | 0.00767493 | 60.9375 | 22341.69 | 0.00 | 41330.62 | 41330.62 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
CORE_BOTTOM VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_BOTTOM VAV BOX | CORE_BOTTOM | N/A | N/A | N/A | Yes | Yes | Yes | No | 16502.305 | 16502.305 | 0.805790 | 0.00014437 | 383.306 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 3.8749 | 3.952879 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:20:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:20:00 | Sensible | 16502.30 | 16502.30 | 1.0000 | 0.84860982 | 0.805790 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | 0.14435463 | 60.00 | 32.22 | 27.78 | 0.000 | 16502.30 | -27.60 | 0.00034190 | -27.60 | 0.00000000 | 0.0000 | 21.00 | 0.00800000 | 21.00 | 0.00800000 | 45.2310 | 9406.54 | 0.00 | 16556.75 | 16556.75 | 0.84860982 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 31.93 | 18.68 | 0.00800000 | 52570.3 | |
CORE_MID VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_MID VAV BOX | CORE_MID | N/A | N/A | N/A | Yes | Yes | Yes | No | 26162.289 | 26162.289 | 0.889541 | 0.00022888 | 690.936 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 6.1432 | 6.266784 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 26162.29 | 26162.29 | 1.0000 | 0.93681094 | 0.889541 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | 0.22885577 | 60.00 | 32.22 | 27.78 | 0.000 | 26162.29 | -27.60 | 0.00034190 | -27.60 | 0.00000000 | 0.0000 | 20.92 | 0.00800000 | 21.00 | 0.00800000 | 45.2310 | 18329.02 | 0.00 | 26255.08 | 26255.08 | 0.93681094 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.28 | 21.27 | 0.00800000 | 61085.8 | |
CORE_TOP VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_TOP VAV BOX | CORE_TOP | N/A | N/A | N/A | Yes | Yes | Yes | No | 46645.006 | 46645.006 | 1.589381 | 0.00040807 | 1230.664 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 10.9527 | 11.173111 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 46645.01 | 46645.01 | 1.0000 | 1.67384002 | 1.589381 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | 0.40802924 | 60.00 | 32.22 | 27.78 | 0.000 | 46645.01 | -27.60 | 0.00034190 | -27.60 | 0.00000000 | 0.0000 | 20.95 | 0.00800000 | 21.00 | 0.00800000 | 45.2310 | 32648.97 | 0.00 | 46801.73 | 46801.73 | 1.67384002 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.22 | 21.25 | 0.00800000 | 61020.5 | |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_3 VAV BOX | PERIMETER_TOP_ZN_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 21338.525 | 21338.525 | 0.728244 | 0.00018668 | 562.579 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 5.0105 | 5.111323 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 21338.52 | 21338.52 | 1.0000 | 0.76694257 | 0.728244 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | 0.18665968 | 60.00 | 32.22 | 27.78 | 0.000 | 21338.52 | -27.60 | 0.00034190 | -27.60 | 0.00000000 | 0.0000 | 20.95 | 0.00788346 | 21.00 | 0.00788346 | 44.5822 | 14927.54 | 0.00 | 21407.28 | 21407.28 | 0.76694257 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.17 | 21.23 | 0.00800000 | 60972.3 | |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_2 VAV BOX | PERIMETER_TOP_ZN_2 | N/A | N/A | N/A | Yes | Yes | Yes | No | 13952.507 | 13952.507 | 0.476192 | 0.00012206 | 367.844 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 3.2762 | 3.342114 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 13952.51 | 13952.51 | 1.0000 | 0.50149700 | 0.476192 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | 0.12205017 | 60.00 | 32.22 | 27.78 | 0.000 | 13952.51 | -27.60 | 0.00034190 | -27.60 | 0.00000000 | 0.0000 | 20.95 | 0.00788124 | 21.00 | 0.00788124 | 44.5699 | 9760.45 | 0.00 | 13997.41 | 13997.41 | 0.50149700 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.17 | 21.23 | 0.00800000 | 60971.1 | |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_1 VAV BOX | PERIMETER_TOP_ZN_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 21517.578 | 21517.578 | 0.734362 | 0.00018825 | 567.297 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 5.0525 | 5.154213 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 21517.58 | 21517.58 | 1.0000 | 0.77338597 | 0.734362 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | 0.18822596 | 60.00 | 32.22 | 27.78 | 0.000 | 21517.58 | -27.60 | 0.00034190 | -27.60 | 0.00000000 | 0.0000 | 20.95 | 0.00788443 | 21.00 | 0.00788443 | 44.5876 | 15052.72 | 0.00 | 21586.89 | 21586.89 | 0.77338597 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.17 | 21.23 | 0.00800000 | 60972.0 | |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_4 VAV BOX | PERIMETER_TOP_ZN_4 | N/A | N/A | N/A | Yes | Yes | Yes | No | 14083.044 | 14083.044 | 0.480653 | 0.00012320 | 371.283 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 3.3068 | 3.373382 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 14083.04 | 14083.04 | 1.0000 | 0.50619447 | 0.480653 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | 0.12319204 | 60.00 | 32.22 | 27.78 | 0.000 | 14083.04 | -27.60 | 0.00034190 | -27.60 | 0.00000000 | 0.0000 | 20.95 | 0.00788233 | 21.00 | 0.00788233 | 44.5760 | 9851.72 | 0.00 | 14128.36 | 14128.36 | 0.50619447 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.17 | 21.23 | 0.00800000 | 60970.8 | |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_3 VAV BOX | PERIMETER_BOT_ZN_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 16684.970 | 16684.970 | 0.569246 | 0.00014597 | 439.954 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 3.9178 | 3.996634 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 16684.97 | 16684.97 | 1.0000 | 0.59949607 | 0.569246 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | 0.14595251 | 60.00 | 32.22 | 27.78 | 0.000 | 16684.97 | -27.60 | 0.00034190 | -27.60 | 0.00000000 | 0.0000 | 20.95 | 0.00791875 | 21.00 | 0.00791875 | 44.7785 | 11673.20 | 0.00 | 16739.19 | 16739.19 | 0.59949607 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.18 | 21.24 | 0.00800000 | 60981.9 | |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_2 VAV BOX | PERIMETER_BOT_ZN_2 | N/A | N/A | N/A | Yes | Yes | Yes | No | 11000.422 | 11000.422 | 0.375328 | 0.00009624 | 290.054 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 2.5830 | 2.634986 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 11000.42 | 11000.42 | 1.0000 | 0.39527337 | 0.375328 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | 0.09622668 | 60.00 | 32.22 | 27.78 | 0.000 | 11000.42 | -27.60 | 0.00034190 | -27.60 | 0.00000000 | 0.0000 | 20.95 | 0.00791838 | 21.00 | 0.00791838 | 44.7765 | 7695.96 | 0.00 | 11036.11 | 11036.11 | 0.39527337 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.18 | 21.24 | 0.00800000 | 60980.0 | |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_1 VAV BOX | PERIMETER_BOT_ZN_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 16856.465 | 16856.465 | 0.575107 | 0.00014747 | 444.473 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 3.9581 | 4.037713 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 16856.47 | 16856.47 | 1.0000 | 0.60566766 | 0.575107 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | 0.14745267 | 60.00 | 32.22 | 27.78 | 0.000 | 16856.47 | -27.60 | 0.00034190 | -27.60 | 0.00000000 | 0.0000 | 20.95 | 0.00791972 | 21.00 | 0.00791972 | 44.7839 | 11793.09 | 0.00 | 16911.22 | 16911.22 | 0.60566766 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.18 | 21.24 | 0.00800000 | 60981.4 | |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_4 VAV BOX | PERIMETER_BOT_ZN_4 | N/A | N/A | N/A | Yes | Yes | Yes | No | 11113.760 | 11113.760 | 0.379201 | 0.00009723 | 293.040 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 2.6096 | 2.662134 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 11113.76 | 11113.76 | 1.0000 | 0.39935209 | 0.379201 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | 0.09721810 | 60.00 | 32.22 | 27.78 | 0.000 | 11113.76 | -27.60 | 0.00034190 | -27.60 | 0.00000000 | 0.0000 | 20.95 | 0.00791932 | 21.00 | 0.00791932 | 44.7817 | 7775.19 | 0.00 | 11149.80 | 11149.80 | 0.39935209 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.18 | 21.24 | 0.00800000 | 60979.5 | |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_3 VAV BOX | PERIMETER_MID_ZN_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 16606.496 | 16606.496 | 0.566556 | 0.00014528 | 437.889 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 3.8994 | 3.977837 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 16606.50 | 16606.50 | 1.0000 | 0.59666323 | 0.566556 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | 0.14526605 | 60.00 | 32.22 | 27.78 | 0.000 | 16606.50 | -27.60 | 0.00034190 | -27.60 | 0.00000000 | 0.0000 | 20.95 | 0.00787375 | 21.00 | 0.00787375 | 44.5278 | 11618.95 | 0.00 | 16660.49 | 16660.49 | 0.59666323 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.18 | 21.24 | 0.00800000 | 60982.6 | |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_2 VAV BOX | PERIMETER_MID_ZN_2 | N/A | N/A | N/A | Yes | Yes | Yes | No | 10930.063 | 10930.063 | 0.372919 | 0.00009562 | 288.202 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 2.5665 | 2.618133 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 10930.06 | 10930.06 | 1.0000 | 0.39273621 | 0.372919 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | 0.09561121 | 60.00 | 32.22 | 27.78 | 0.000 | 10930.06 | -27.60 | 0.00034190 | -27.60 | 0.00000000 | 0.0000 | 20.95 | 0.00787266 | 21.00 | 0.00787266 | 44.5218 | 7647.17 | 0.00 | 10965.54 | 10965.54 | 0.39273621 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.18 | 21.24 | 0.00800000 | 60980.7 | |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_1 VAV BOX | PERIMETER_MID_ZN_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 16760.063 | 16760.063 | 0.571804 | 0.00014662 | 441.936 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 3.9354 | 4.014622 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 16760.06 | 16760.06 | 1.0000 | 0.60218966 | 0.571804 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | 0.14660939 | 60.00 | 32.22 | 27.78 | 0.000 | 16760.06 | -27.60 | 0.00034190 | -27.60 | 0.00000000 | 0.0000 | 20.95 | 0.00787503 | 21.00 | 0.00787503 | 44.5350 | 11726.31 | 0.00 | 16814.54 | 16814.54 | 0.60218966 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.18 | 21.24 | 0.00800000 | 60982.2 | |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_4 VAV BOX | PERIMETER_MID_ZN_4 | N/A | N/A | N/A | Yes | Yes | Yes | No | 11046.339 | 11046.339 | 0.376893 | 0.00009664 | 291.266 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 2.5938 | 2.645985 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 11046.34 | 11046.34 | 1.0000 | 0.39692065 | 0.376893 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 40.00 | 19.63 | 0.00800000 | 60796.0 | 0.09662834 | 60.00 | 32.22 | 27.78 | 0.000 | 11046.34 | -27.60 | 0.00034190 | -27.60 | 0.00000000 | 0.0000 | 20.95 | 0.00787410 | 21.00 | 0.00787410 | 44.5298 | 7728.46 | 0.00 | 11082.18 | 11082.18 | 0.39692065 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.18 | 21.24 | 0.00800000 | 60980.2 | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_BOT | CORE_BOTTOM; PERIMETER_BOT_ZN_1; PERIMETER_BOT_ZN_2; PERIMETER_BOT_ZN_3; PERIMETER_BOT_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 93545.070 | 74897.352 | 5.651058 | -999.0 | -999.000 | -999.0000 | 1.01106 | 1.00000 | 1020.1966 | 1004.8586 | 1.0531 | PACU_VAV_BOT FAN | Fan:VariableVolume | 5.651058 | 5.95135418 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | Sensible | 91437.06 | 91437.06 | 0.9775 | 5.95135418 | 5.651058 | 25.99 | 15.50 | 0.00826090 | 47174.1 | 10.66 | 9.79 | 0.00826090 | 31536.0 | -999.0 | -999.00 | -999.00 | -999.00 | 12988.739 | 78448.33 | 33.40 | 0.00630683 | 16.37 | 1.19517000 | 21.1495 | 24.00 | 0.00878571 | 24.00 | 0.00878571 | 41.3468 | 67952.95 | 0.00 | 96457.52 | 71070.07 | 5.71632068 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.51 | 13.70 | 0.00944336 | 38448.3 | |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | PACU_VAV_BOT | CORE_BOTTOM; PERIMETER_BOT_ZN_1; PERIMETER_BOT_ZN_2; PERIMETER_BOT_ZN_3; PERIMETER_BOT_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 47996.911 | 47996.911 | 1.695317 | 0.00041990 | 747.598 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PACU_VAV_BOT FAN | Fan:VariableVolume | 5.651058 | 5.95135418 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 11.2701 | 11.496939 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 06:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 47996.91 | 47996.91 | 1.0000 | 1.78540625 | 1.695317 | -13.95 | -13.95 | 0.00255519 | -7696.4 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 0.41985508 | 60.00 | 32.22 | 27.78 | 0.000 | 47996.91 | -27.60 | 0.00034190 | -27.60 | 1.19517000 | 70.4983 | 18.66 | 0.00784416 | 18.18 | 0.00784947 | 52.8848 | 20159.43 | 0.00 | 39715.96 | 39715.96 | 1.78540625 | 2.80 | -0.33 | 0.00255519 | 9217.2 | 24.83 | 11.04 | 0.00255519 | 31462.0 | |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_MID | CORE_MID; PERIMETER_MID_ZN_1; PERIMETER_MID_ZN_2; PERIMETER_MID_ZN_3; PERIMETER_MID_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 88415.297 | 70790.173 | 5.341168 | -999.0 | -999.000 | -999.0000 | 1.00365 | 1.00000 | 1020.1526 | 1004.8586 | 1.0531 | PACU_VAV_MID FAN | Fan:VariableVolume | 5.341168 | 5.62499714 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | Sensible | 86422.89 | 86422.89 | 0.9775 | 5.62499714 | 5.341168 | 26.11 | 15.52 | 0.00823724 | 47235.2 | 10.66 | 9.77 | 0.00823724 | 31476.3 | -999.0 | -999.00 | -999.00 | -999.00 | 12276.469 | 74146.42 | 33.40 | 0.00630683 | 16.37 | 1.19517000 | 22.3766 | 24.00 | 0.00879568 | 24.00 | 0.00879568 | 41.3929 | 64119.33 | 0.00 | 91168.04 | 67172.77 | 5.40285228 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.51 | 13.70 | 0.00944336 | 38448.3 | |
PACU_VAV_MID HEATING COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | PACU_VAV_MID | CORE_MID; PERIMETER_MID_ZN_1; PERIMETER_MID_ZN_2; PERIMETER_MID_ZN_3; PERIMETER_MID_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 49080.553 | 49080.553 | 1.602350 | 0.00042938 | 753.209 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PACU_VAV_MID FAN | Fan:VariableVolume | 5.341168 | 5.62499714 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 11.5246 | 11.756510 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 05:40:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 49080.55 | 49080.55 | 1.0000 | 1.68749914 | 1.602350 | -16.14 | -16.14 | 0.00222936 | -10713.7 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 0.42933429 | 60.00 | 32.22 | 27.78 | 0.000 | 49080.55 | -27.60 | 0.00034190 | -27.60 | 1.19517000 | 74.5886 | 17.48 | 0.00776949 | 17.60 | 0.00765130 | 53.4967 | 19423.89 | 0.00 | 39759.71 | 39759.71 | 1.68749914 | 2.80 | -0.83 | 0.00222936 | 8400.6 | 26.15 | 11.26 | 0.00222936 | 31962.0 | |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_TOP | CORE_TOP; PERIMETER_TOP_ZN_1; PERIMETER_TOP_ZN_2; PERIMETER_TOP_ZN_3; PERIMETER_TOP_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 101329.651 | 81130.118 | 6.121324 | -999.0 | -999.000 | -999.0000 | 1.02021 | 1.00000 | 1020.2223 | 1004.8586 | 1.0531 | PACU_VAV_TOP FAN | Fan:VariableVolume | 6.121324 | 6.44661066 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | Sensible | 99046.22 | 99046.22 | 0.9775 | 6.44661066 | 6.121324 | 25.84 | 15.46 | 0.00827473 | 47061.9 | 10.66 | 9.81 | 0.00827473 | 31571.0 | -999.0 | -999.00 | -999.00 | -999.00 | 14069.628 | 84976.59 | 33.40 | 0.00630683 | 16.37 | 1.19517000 | 19.5247 | 24.00 | 0.00875549 | 24.00 | 0.00875549 | 41.2063 | 73277.23 | 0.00 | 104484.47 | 76984.34 | 6.19201827 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 14.51 | 13.70 | 0.00944336 | 38448.3 | |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | PACU_VAV_TOP | CORE_TOP; PERIMETER_TOP_ZN_1; PERIMETER_TOP_ZN_2; PERIMETER_TOP_ZN_3; PERIMETER_TOP_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 49198.252 | 49198.252 | 1.836397 | 0.00043041 | 771.376 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PACU_VAV_TOP FAN | Fan:VariableVolume | 6.121324 | 6.44661066 | 4197.9300 | 999.8980 | 3.65188566 | 54.44 | 82.22 | 27.78 | 425877.41 | 11.5522 | 11.784703 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 03:50:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 49198.25 | 49198.25 | 1.0000 | 1.93398320 | 1.836397 | -12.52 | -12.52 | 0.00293518 | -5304.0 | 12.80 | 10.41 | 0.00800000 | 33059.8 | 0.43036386 | 60.00 | 32.22 | 27.78 | 0.000 | 49198.25 | -27.60 | 0.00034190 | -27.60 | 1.19517000 | 65.0823 | 15.60 | 0.00776874 | 15.60 | 0.00767493 | 60.9375 | 22341.69 | 0.00 | 41330.62 | 41330.62 | 1.93398320 | 2.80 | 0.43 | 0.00293518 | 10169.5 | 23.95 | 11.07 | 0.00293518 | 31540.3 |
Report: System Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PACU_VAV_BOT_OA_CONTROLLER | DifferentialDryBulb | 0.00 | 5.65 | - | |||
PACU_VAV_MID_OA_CONTROLLER | DifferentialDryBulb | 0.00 | 5.34 | - | |||
PACU_VAV_TOP_OA_CONTROLLER | DifferentialDryBulb | 0.00 | 6.12 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
CORE_BOTTOM | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORE_MID | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORE_TOP | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_3 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_2 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_1 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_4 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
CORE_BOTTOM | 1342.50 | 2985.67 | 116.33 |
CORE_MID | 1479.17 | 4004.33 | 698.00 |
CORE_TOP | 2179.50 | 4322.00 | 1517.50 |
PERIMETER_TOP_ZN_3 | 3192.83 | 4476.83 | 2450.50 |
PERIMETER_TOP_ZN_2 | 3360.50 | 4160.83 | 2223.50 |
PERIMETER_TOP_ZN_1 | 3024.67 | 3883.83 | 1799.83 |
PERIMETER_TOP_ZN_4 | 3299.33 | 4411.50 | 2304.67 |
PERIMETER_BOT_ZN_3 | 2800.50 | 4578.67 | 2224.67 |
PERIMETER_BOT_ZN_2 | 3031.67 | 4015.33 | 1831.50 |
PERIMETER_BOT_ZN_1 | 2692.17 | 3914.33 | 1508.00 |
PERIMETER_BOT_ZN_4 | 2960.50 | 4196.33 | 1912.00 |
PERIMETER_MID_ZN_3 | 2748.50 | 4270.17 | 1924.17 |
PERIMETER_MID_ZN_2 | 2545.33 | 3499.67 | 1592.17 |
PERIMETER_MID_ZN_1 | 2715.50 | 3576.50 | 1329.33 |
PERIMETER_MID_ZN_4 | 2920.00 | 4167.50 | 1821.83 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
Facility | 4720.50 | 4941.67 | 2745.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
CORE_BOTTOM | 0.00 | 0.33 | 0.00 | 0.00 |
CORE_MID | 3.17 | 0.00 | 3.00 | 0.00 |
CORE_TOP | 13.83 | 0.00 | 11.83 | 0.00 |
PERIMETER_TOP_ZN_3 | 150.33 | 5.50 | 78.83 | 4.00 |
PERIMETER_TOP_ZN_2 | 102.33 | 23.67 | 35.67 | 22.67 |
PERIMETER_TOP_ZN_1 | 84.67 | 26.83 | 31.83 | 24.67 |
PERIMETER_TOP_ZN_4 | 97.33 | 26.50 | 32.83 | 13.50 |
PERIMETER_BOT_ZN_3 | 68.83 | 0.00 | 51.50 | 0.00 |
PERIMETER_BOT_ZN_2 | 29.17 | 18.83 | 13.83 | 18.00 |
PERIMETER_BOT_ZN_1 | 405.50 | 25.50 | 396.00 | 23.00 |
PERIMETER_BOT_ZN_4 | 28.50 | 18.50 | 14.17 | 9.00 |
PERIMETER_MID_ZN_3 | 61.83 | 2.50 | 38.17 | 1.83 |
PERIMETER_MID_ZN_2 | 35.67 | 24.17 | 13.00 | 23.67 |
PERIMETER_MID_ZN_1 | 28.33 | 30.67 | 13.17 | 28.83 |
PERIMETER_MID_ZN_4 | 36.33 | 25.50 | 13.83 | 12.83 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 533.50 | 130.83 | 438.50 | 104.50 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
CORE_BOTTOM | 21.56 | 52.94 | 2698.04 | 0.975 | 0.000 | 0.000 | 0.000 |
CORE_MID | 21.56 | 52.94 | 2698.04 | 0.688 | 0.000 | 0.000 | 0.000 |
CORE_TOP | 21.56 | 52.94 | 2698.04 | 0.667 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_3 | 4.54 | 11.16 | 568.77 | 0.748 | 0.051 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_2 | 2.88 | 7.07 | 360.08 | 1.441 | 0.054 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_1 | 4.54 | 11.16 | 568.77 | 1.371 | 0.051 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_4 | 2.88 | 7.06 | 360.05 | 1.420 | 0.054 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_3 | 4.54 | 11.16 | 568.77 | 0.654 | 0.027 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_2 | 2.88 | 7.07 | 360.08 | 1.217 | 0.029 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_1 | 4.54 | 11.16 | 568.77 | 1.085 | 0.849 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_4 | 2.88 | 7.06 | 360.05 | 1.132 | 0.029 | 0.000 | 0.000 |
PERIMETER_MID_ZN_3 | 4.54 | 11.16 | 568.77 | 0.743 | 0.043 | 0.000 | 0.000 |
PERIMETER_MID_ZN_2 | 2.52 | 7.07 | 360.08 | 1.336 | 0.048 | 0.000 | 0.000 |
PERIMETER_MID_ZN_1 | 4.54 | 11.16 | 568.77 | 1.359 | 0.043 | 0.000 | 0.000 |
PERIMETER_MID_ZN_4 | 2.88 | 7.06 | 360.05 | 1.364 | 0.045 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
CORE_BOTTOM | 21.56 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
CORE_MID | 21.56 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
CORE_TOP | 21.56 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_3 | 4.54 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_2 | 2.88 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_1 | 4.54 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_4 | 2.88 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_3 | 4.54 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_2 | 2.88 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_1 | 4.54 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_4 | 2.88 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_3 | 4.54 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_2 | 2.52 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_1 | 4.54 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_4 | 2.88 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Mechanical Ventilation Parameters by ZoneAirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
CORE_BOTTOM | PACU_VAV_BOT | 21.56 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
CORE_MID | PACU_VAV_MID | 21.56 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
CORE_TOP | PACU_VAV_TOP | 21.56 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | 4.54 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | 2.88 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | 4.54 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | 2.88 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | 4.54 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | 2.88 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | 4.54 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | 2.88 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | 4.54 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | 2.52 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | 4.54 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | 2.88 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
Total Facility | 108.84 | 268.17 | 13667.13 | 4982.19 | 0.0000 | 2.151 |
Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
CORE_BOTTOM | 15516790.86 | 0.00 | 15516790.86 | 0.00 | 15516790.86 | 13393058.27 | 5675.58 | 48.10 | 3036.32 | 138.32 |
CORE_MID | 10996492.43 | 0.00 | 10996492.43 | 0.00 | 10996492.43 | 13393058.27 | 6453.77 | 33.61 | 2272.62 | 158.10 |
CORE_TOP | 10678111.10 | 0.00 | 10678111.10 | 0.00 | 10678111.10 | 13393058.27 | 6512.43 | 27.43 | 2220.14 | 81.97 |
PERIMETER_TOP_ZN_3 | 2520594.81 | 0.00 | 2520594.81 | 341693.17 | 2862287.98 | 2823374.22 | 5824.92 | 55.06 | 2880.02 | 81.97 |
PERIMETER_TOP_ZN_2 | 3072846.18 | 0.00 | 3072846.18 | 227794.08 | 3300640.26 | 1787429.43 | 4100.90 | 2.63 | 4656.46 | 81.97 |
PERIMETER_TOP_ZN_1 | 4606151.87 | 0.00 | 4606151.87 | 341693.17 | 4947845.05 | 2823374.22 | 4121.82 | 1.60 | 4636.58 | 81.97 |
PERIMETER_TOP_ZN_4 | 3045730.95 | 0.00 | 3045730.95 | 227794.08 | 3273525.03 | 1787312.18 | 4107.14 | 8.37 | 4644.49 | 81.97 |
PERIMETER_BOT_ZN_3 | 2215756.28 | 0.00 | 2215756.28 | 181675.92 | 2397432.20 | 2823374.22 | 6200.23 | 43.30 | 2516.48 | 138.32 |
PERIMETER_BOT_ZN_2 | 2598074.53 | 0.00 | 2598074.53 | 121116.55 | 2719191.09 | 1787429.43 | 4079.21 | 6.74 | 4674.06 | 138.32 |
PERIMETER_BOT_ZN_1 | 3660680.13 | 0.00 | 3660680.13 | 2939420.97 | 6600101.10 | 2823374.22 | 4272.43 | 50.34 | 4437.23 | 138.32 |
PERIMETER_BOT_ZN_4 | 2429651.03 | 0.00 | 2429651.03 | 121116.55 | 2550767.58 | 1787312.18 | 4102.61 | 19.41 | 4637.98 | 138.32 |
PERIMETER_MID_ZN_3 | 2503245.14 | 0.00 | 2503245.14 | 284432.92 | 2787678.05 | 2823374.22 | 5967.15 | 62.26 | 2730.58 | 158.10 |
PERIMETER_MID_ZN_2 | 3106096.57 | 0.00 | 3106096.57 | 189620.80 | 3295717.37 | 1787429.43 | 4028.08 | 3.31 | 4728.61 | 1067.10 |
PERIMETER_MID_ZN_1 | 4560927.43 | 0.00 | 4560927.43 | 284432.92 | 4845360.34 | 2823374.22 | 4080.33 | 6.89 | 4672.78 | 158.10 |
PERIMETER_MID_ZN_4 | 2923456.44 | 0.00 | 2923456.44 | 189620.80 | 3113077.24 | 1787312.18 | 4035.76 | 9.44 | 4714.80 | 158.10 |
Total Facility | 74434605.74 | 0.00 | 74434605.74 | 5450411.94 | 79885017.69 | 67843644.98 | 6692.73 | 287.04 | 4823.40 | 1147.89 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
CORE_BOTTOM | 0.7170 | 0.0000 | 0.7170 | 0.0000 | 0.7170 | 0.4247 | 2911.62 | 48.10 | 2983.28 |
CORE_MID | 0.5069 | 0.0000 | 0.5069 | 0.0000 | 0.5069 | 0.4247 | 3683.52 | 33.61 | 2225.88 |
CORE_TOP | 0.4920 | 0.0000 | 0.4920 | 0.0000 | 0.4920 | 0.4247 | 3745.97 | 27.43 | 2169.60 |
PERIMETER_TOP_ZN_3 | 0.1163 | 0.0000 | 0.1163 | 0.0080 | 0.1243 | 0.0895 | 3058.46 | 55.06 | 2829.48 |
PERIMETER_TOP_ZN_2 | 0.1419 | 0.0000 | 0.1419 | 0.0053 | 0.1473 | 0.0567 | 1334.44 | 2.63 | 4605.93 |
PERIMETER_TOP_ZN_1 | 0.2131 | 0.0000 | 0.2131 | 0.0080 | 0.2211 | 0.0895 | 1355.36 | 1.60 | 4586.04 |
PERIMETER_TOP_ZN_4 | 0.1400 | 0.0000 | 0.1400 | 0.0053 | 0.1453 | 0.0567 | 1340.68 | 8.37 | 4593.95 |
PERIMETER_BOT_ZN_3 | 0.1018 | 0.0000 | 0.1018 | 0.0043 | 0.1061 | 0.0895 | 3436.16 | 43.30 | 2463.55 |
PERIMETER_BOT_ZN_2 | 0.1198 | 0.0000 | 0.1198 | 0.0028 | 0.1226 | 0.0567 | 1316.37 | 6.71 | 4619.93 |
PERIMETER_BOT_ZN_1 | 0.1690 | 0.0000 | 0.1690 | 0.1332 | 0.3021 | 0.0895 | 1508.36 | 50.34 | 4384.31 |
PERIMETER_BOT_ZN_4 | 0.1115 | 0.0000 | 0.1115 | 0.0028 | 0.1144 | 0.0567 | 1339.85 | 19.34 | 4583.81 |
PERIMETER_MID_ZN_3 | 0.1155 | 0.0000 | 0.1155 | 0.0067 | 0.1222 | 0.0895 | 3196.90 | 62.26 | 2683.84 |
PERIMETER_MID_ZN_2 | 0.1316 | 0.0000 | 0.1316 | 0.0047 | 0.1363 | 0.0567 | 1257.36 | 2.96 | 3773.68 |
PERIMETER_MID_ZN_1 | 0.2111 | 0.0000 | 0.2111 | 0.0067 | 0.2177 | 0.0895 | 1310.07 | 6.89 | 4626.04 |
PERIMETER_MID_ZN_4 | 0.1344 | 0.0000 | 0.1344 | 0.0044 | 0.1388 | 0.0567 | 1265.74 | 9.44 | 4667.82 |
Total Facility | 3.4219 | 0.0000 | 3.4219 | 0.1923 | 3.6141 | 2.1513 | 3900.57 | 286.92 | 4745.14 |
Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
PACU_VAV_BOT | 29303574.08 | 0.00 | 29303574.08 | 22614548.33 | 4106.05 | 4.03 | 4649.92 | 138.32 |
PACU_VAV_MID | 26718547.67 | 0.00 | 26718547.67 | 22614548.33 | 4095.27 | 3.26 | 4661.48 | 157.99 |
PACU_VAV_TOP | 26533567.95 | 0.00 | 26533567.95 | 22614548.33 | 4126.31 | 2.28 | 4631.41 | 81.97 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
PACU_VAV_BOT | 1.3522 | 0.0000 | 1.3522 | 0.7171 | 1342.09 | 4.03 | 4596.88 |
PACU_VAV_MID | 1.2326 | 0.0000 | 1.2326 | 0.7171 | 1325.01 | 3.26 | 4614.73 |
PACU_VAV_TOP | 1.2236 | 0.0000 | 1.2236 | 0.7171 | 1359.85 | 2.28 | 4580.87 |
No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
PACU_VAV_BOT | 0.00 | 0.00 | 3029.59 | 0.00 | 0.00 | 0.00 | 1904.29 | 0.00 | 0.00 | 0.00 |
PACU_VAV_MID | 0.00 | 0.08 | 2793.96 | 0.00 | 0.00 | 0.00 | 2187.94 | 0.00 | 0.00 | 0.00 |
PACU_VAV_TOP | 0.00 | 0.00 | 2655.59 | 0.00 | 0.00 | 0.00 | 2204.76 | 0.00 | 0.00 | 0.00 |
No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
PACU_VAV_BOT | 0.0000 | 0.0000 | 2.1957 | 0.0000 | 0.0000 | 0.0000 | 0.8866 | 0.0000 | 0.0000 | 0.0000 |
PACU_VAV_MID | 0.0000 | 0.0000 | 2.0417 | 0.0000 | 0.0000 | 0.0000 | 0.8893 | 0.0000 | 0.0000 | 0.0000 |
PACU_VAV_TOP | 0.0000 | 0.0000 | 2.0685 | 0.0000 | 0.0000 | 0.0000 | 0.8845 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Surfaces by ClassTotal | Outdoors | |
Wall | 72 | 24 |
Floor | 30 | 4 |
Roof | 26 | 1 |
Internal Mass | 15 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 18 | 18 |
Door | 6 | 6 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 3 |
Conditioned Zones | 18 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 3 |
Count | |
IDF Objects | 982 |
Defaulted Fields | 577 |
Fields with Defaults | 2420 |
Autosized Fields | 193 |
Autosizable Fields | 250 |
Autocalculated Fields | 156 |
Autocalculatable Fields | 277 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1376.01 | 13834.26 | 26-MAR-17:30 | 185342.42 | 17-JUL-15:30 |
Electricity:Building | 1021.47 | 13465.67 | 26-MAR-17:20 | 74341.76 | 02-JAN-08:10 |
Electricity:Zone:CORE_BOTTOM | 322.35 | 5243.28 | 01-JAN-00:10 | 20463.73 | 02-JAN-08:10 |
Electricity:SpaceType:GENERAL | 1021.47 | 13465.67 | 26-MAR-17:20 | 74341.76 | 02-JAN-08:10 |
InteriorLights:Electricity | 301.78 | 987.92 | 26-MAR-17:20 | 32642.50 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_BOTTOM | 71.93 | 211.73 | 01-JAN-00:10 | 6443.98 | 02-JAN-08:10 |
InteriorLights:Electricity:SpaceType:GENERAL | 301.78 | 987.92 | 26-MAR-17:20 | 32642.50 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity | 301.78 | 987.92 | 26-MAR-17:20 | 32642.50 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_BOTTOM | 71.93 | 211.73 | 01-JAN-00:10 | 6443.98 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 301.78 | 987.92 | 26-MAR-17:20 | 32642.50 | 02-JAN-08:10 |
Electricity:Zone:CORE_MID | 187.35 | 2043.28 | 01-JAN-00:10 | 13252.30 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_MID | 71.93 | 211.73 | 01-JAN-00:10 | 6443.98 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_MID | 71.93 | 211.73 | 01-JAN-00:10 | 6443.98 | 02-JAN-08:10 |
Electricity:Zone:CORE_TOP | 187.35 | 2043.28 | 01-JAN-00:10 | 13252.30 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_TOP | 71.93 | 211.73 | 01-JAN-00:10 | 6443.98 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_TOP | 71.93 | 211.73 | 01-JAN-00:10 | 6443.98 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_TOP_ZN_3 | 33.24 | 422.10 | 26-MAR-17:10 | 2793.69 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_3 | 8.91 | 36.00 | 01-JAN-10:50 | 1358.45 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_3 | 8.91 | 36.00 | 01-JAN-10:50 | 1358.45 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_TOP_ZN_2 | 20.95 | 267.21 | 26-MAR-17:10 | 1768.58 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_2 | 5.55 | 22.79 | 01-JAN-08:50 | 860.01 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_2 | 5.55 | 22.79 | 01-JAN-08:50 | 860.01 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_TOP_ZN_1 | 33.00 | 422.10 | 12-MAR-17:10 | 2793.68 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_1 | 8.67 | 36.00 | 01-JAN-08:50 | 1358.45 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_1 | 8.67 | 36.00 | 01-JAN-08:50 | 1358.45 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_TOP_ZN_4 | 20.97 | 267.21 | 12-MAR-17:10 | 1768.52 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_4 | 5.57 | 22.79 | 01-JAN-10:30 | 859.95 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_4 | 5.57 | 22.79 | 01-JAN-10:30 | 859.95 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_BOT_ZN_3 | 33.21 | 422.10 | 19-MAR-17:10 | 2793.69 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_3 | 8.88 | 36.00 | 01-JAN-10:30 | 1358.45 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_3 | 8.88 | 36.00 | 01-JAN-10:30 | 1358.45 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_BOT_ZN_2 | 20.94 | 267.21 | 26-MAR-17:10 | 1768.58 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_2 | 5.53 | 22.79 | 01-JAN-08:50 | 860.01 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_2 | 5.53 | 22.79 | 01-JAN-08:50 | 860.01 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_BOT_ZN_1 | 32.98 | 422.10 | 12-MAR-17:10 | 2793.68 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_1 | 8.65 | 36.00 | 01-JAN-08:50 | 1358.45 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_1 | 8.65 | 36.00 | 01-JAN-08:50 | 1358.45 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_BOT_ZN_4 | 20.96 | 267.21 | 12-MAR-17:10 | 1768.52 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_4 | 5.55 | 22.79 | 01-JAN-10:30 | 859.95 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_4 | 5.55 | 22.79 | 01-JAN-10:30 | 859.95 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_MID_ZN_3 | 33.24 | 422.10 | 26-MAR-17:10 | 2793.69 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_3 | 8.91 | 36.00 | 01-JAN-10:50 | 1358.45 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_3 | 8.91 | 36.00 | 01-JAN-10:50 | 1358.45 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_MID_ZN_2 | 20.95 | 267.21 | 26-MAR-17:10 | 1768.58 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_2 | 5.55 | 22.79 | 01-JAN-08:50 | 860.01 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_2 | 5.55 | 22.79 | 01-JAN-08:50 | 860.01 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_MID_ZN_1 | 33.00 | 422.10 | 12-MAR-17:10 | 2793.68 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_1 | 8.67 | 36.00 | 01-JAN-08:50 | 1358.45 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_1 | 8.67 | 36.00 | 01-JAN-08:50 | 1358.45 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_MID_ZN_4 | 20.97 | 267.21 | 12-MAR-17:10 | 1768.52 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_4 | 5.57 | 22.79 | 01-JAN-10:30 | 859.95 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_4 | 5.57 | 22.79 | 01-JAN-10:30 | 859.95 | 02-JAN-08:10 |
InteriorEquipment:Electricity | 719.69 | 12477.75 | 01-JAN-00:10 | 41699.26 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 250.42 | 5031.54 | 01-JAN-00:10 | 14019.75 | 02-JAN-08:10 |
InteriorEquipment:Electricity:SpaceType:GENERAL | 719.69 | 12477.75 | 01-JAN-00:10 | 41699.26 | 02-JAN-08:10 |
ElevatorLift:InteriorEquipment:Electricity | 134.36 | 3200.00 | 01-JAN-00:10 | 7125.18 | 02-JAN-07:10 |
ElevatorLift:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 134.36 | 3200.00 | 01-JAN-00:10 | 7125.18 | 02-JAN-07:10 |
ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 134.36 | 3200.00 | 01-JAN-00:10 | 7125.18 | 02-JAN-07:10 |
ElevatorLightsFan:InteriorEquipment:Electricity | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
ElevatorLightsFan:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity | 584.69 | 9277.75 | 01-JAN-00:10 | 34487.83 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 584.69 | 9277.75 | 01-JAN-00:10 | 34487.83 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_MID | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_MID | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_TOP | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_TOP | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
Electricity:HVAC | 240.77 | 367.92 | 01-JAN-00:10 | 113384.49 | 17-JUL-15:30 |
ExteriorEquipment:Electricity | 26.90 | 367.92 | 01-JAN-00:10 | 1410.29 | 04-JAN-12:10 |
Transformer:ExteriorEquipment:Electricity | 26.90 | 367.92 | 01-JAN-00:10 | 1410.29 | 04-JAN-12:10 |
ElectricityPurchased:Facility | 1376.01 | 13834.26 | 26-MAR-17:30 | 185342.42 | 17-JUL-15:30 |
ElectricityPurchased:Plant | 1376.01 | 13834.26 | 26-MAR-17:30 | 185342.42 | 17-JUL-15:30 |
Cogeneration:ElectricityPurchased | 1376.01 | 13834.26 | 26-MAR-17:30 | 185342.42 | 17-JUL-15:30 |
General:Cogeneration:ElectricityPurchased | 1376.01 | 13834.26 | 26-MAR-17:30 | 185342.42 | 17-JUL-15:30 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1376.01 | 13834.26 | 26-MAR-17:30 | 185342.42 | 17-JUL-15:30 |
ElectricityNet:Plant | 1376.01 | 13834.26 | 26-MAR-17:30 | 185342.42 | 17-JUL-15:30 |
Cogeneration:ElectricityNet | 1376.01 | 13834.26 | 26-MAR-17:30 | 185342.42 | 17-JUL-15:30 |
General:Cogeneration:ElectricityNet | 1376.01 | 13834.26 | 26-MAR-17:30 | 185342.42 | 17-JUL-15:30 |
Fans:Electricity | 107.32 | 0.00 | 01-JAN-00:10 | 36534.75 | 17-JUL-15:30 |
General:Fans:Electricity | 107.32 | 0.00 | 01-JAN-00:10 | 36534.75 | 17-JUL-15:30 |
ExteriorLights:Electricity | 51.81 | 0.00 | 01-JAN-08:20 | 5686.19 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 51.81 | 0.00 | 01-JAN-08:20 | 5686.19 | 01-JAN-06:10 |
Cooling:Electricity | 106.54 | 0.00 | 01-JAN-00:10 | 75865.04 | 17-JUL-16:00 |
General:Cooling:Electricity | 106.54 | 0.00 | 01-JAN-00:10 | 75865.04 | 17-JUL-16:00 |
Electricity:Plant | 61.97 | 0.00 | 01-JAN-00:10 | 8142.04 | 09-JAN-13:00 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:Electricity | 59.04 | 0.00 | 01-JAN-00:10 | 7227.29 | 17-FEB-12:50 |
Water Heater:WaterSystems:Electricity | 59.04 | 0.00 | 01-JAN-00:10 | 7227.29 | 17-FEB-12:50 |
Pumps:Electricity | 2.93 | 0.00 | 01-JAN-00:10 | 1064.89 | 09-JAN-09:40 |
General:Pumps:Electricity | 2.93 | 0.00 | 01-JAN-00:10 | 1064.89 | 09-JAN-09:40 |
WIRED_LTG_ELECTRICITY | 8.48 | 0.00 | 01-JAN-00:10 | 917.25 | 02-JAN-08:20 |
WIRED_INT_EQUIP1 | 680.83 | 12477.75 | 01-JAN-00:10 | 37555.83 | 02-JAN-13:10 |
WIRED_INT_EQUIP2 | 624.19 | 9277.75 | 01-JAN-00:10 | 39135.32 | 02-JAN-08:10 |
Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
NaturalGas:Facility | 588.15 | 0.00 | 01-JAN-00:10 | 326022.83 | 09-JAN-07:20 |
NaturalGas:Plant | 588.15 | 0.00 | 01-JAN-00:10 | 326022.83 | 09-JAN-07:20 |
Heating:NaturalGas | 588.15 | 0.00 | 01-JAN-00:10 | 326022.83 | 09-JAN-07:20 |
Boiler:Heating:NaturalGas | 588.15 | 0.00 | 01-JAN-00:10 | 326022.83 | 09-JAN-07:20 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 05-JAN-12:10 |
Water:Plant | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 05-JAN-12:10 |
WaterSystems:Water | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 05-JAN-12:10 |
WaterUse:WaterSystems:Water | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 05-JAN-12:10 |
MainsWater:Facility | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 05-JAN-12:10 |
MainsWater:Plant | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 05-JAN-12:10 |
WaterSystems:MainsWater | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 05-JAN-12:10 |
WaterUse:WaterSystems:MainsWater | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 05-JAN-12:10 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
EnergyTransfer:Facility | 2467.32 | 0.00 | 01-JAN-00:10 | 673062.96 | 09-JAN-07:10 |
EnergyTransfer:Building | 1133.61 | 0.00 | 01-JAN-00:10 | 187361.31 | 17-JUL-15:30 |
EnergyTransfer:Zone:CORE_BOTTOM | 213.52 | 0.00 | 01-JAN-00:10 | 26010.93 | 05-SEP-07:50 |
Heating:EnergyTransfer | 195.55 | 0.00 | 01-JAN-00:10 | 162767.89 | 09-JAN-06:10 |
Heating:EnergyTransfer:Zone:CORE_BOTTOM | 0.01 | 0.00 | 01-JAN-00:10 | 3832.79 | 09-JAN-07:10 |
General:Heating:EnergyTransfer | 195.55 | 0.00 | 01-JAN-00:10 | 162767.89 | 09-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:CORE_BOTTOM | 0.01 | 0.00 | 01-JAN-00:10 | 3832.79 | 09-JAN-07:10 |
Cooling:EnergyTransfer | 938.06 | 0.00 | 01-JAN-00:10 | 187361.31 | 17-JUL-15:30 |
Cooling:EnergyTransfer:Zone:CORE_BOTTOM | 213.51 | 0.00 | 01-JAN-00:10 | 26010.93 | 05-SEP-07:50 |
General:Cooling:EnergyTransfer | 938.06 | 0.00 | 01-JAN-00:10 | 187361.31 | 17-JUL-15:30 |
General:Cooling:EnergyTransfer:Zone:CORE_BOTTOM | 213.51 | 0.00 | 01-JAN-00:10 | 26010.93 | 05-SEP-07:50 |
EnergyTransfer:Zone:TOPFLOOR_PLENUM | 58.08 | 0.00 | 01-JAN-00:10 | 17737.69 | 11-JAN-06:20 |
Heating:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 31.81 | 0.00 | 01-JAN-00:10 | 17737.69 | 11-JAN-06:20 |
General:Heating:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 31.81 | 0.00 | 01-JAN-00:10 | 17737.69 | 11-JAN-06:20 |
Cooling:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 26.27 | 0.00 | 01-JAN-00:10 | 13035.23 | 17-JUL-15:00 |
General:Cooling:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 26.27 | 0.00 | 01-JAN-00:10 | 13035.23 | 17-JUL-15:00 |
EnergyTransfer:Zone:MIDFLOOR_PLENUM | 27.20 | 0.00 | 01-JAN-00:10 | 10106.62 | 09-JAN-08:20 |
Heating:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 12.71 | 0.00 | 01-JAN-00:10 | 10106.62 | 09-JAN-08:20 |
General:Heating:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 12.71 | 0.00 | 01-JAN-00:10 | 10106.62 | 09-JAN-08:20 |
Cooling:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 14.49 | 0.00 | 01-JAN-00:10 | 6171.05 | 17-JUL-15:30 |
General:Cooling:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 14.49 | 0.00 | 01-JAN-00:10 | 6171.05 | 17-JUL-15:30 |
EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 26.65 | 0.00 | 01-JAN-00:10 | 6399.32 | 17-JUL-16:00 |
Heating:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 7.58 | 0.00 | 01-JAN-00:10 | 5288.67 | 09-JAN-12:00 |
General:Heating:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 7.58 | 0.00 | 01-JAN-00:10 | 5288.67 | 09-JAN-12:00 |
Cooling:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 19.07 | 0.00 | 01-JAN-00:10 | 6399.32 | 17-JUL-16:00 |
General:Cooling:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 19.07 | 0.00 | 01-JAN-00:10 | 6399.32 | 17-JUL-16:00 |
EnergyTransfer:Zone:CORE_MID | 140.30 | 0.00 | 01-JAN-00:10 | 20366.01 | 05-SEP-07:30 |
Heating:EnergyTransfer:Zone:CORE_MID | 1.60 | 0.00 | 01-JAN-00:10 | 15355.89 | 09-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:CORE_MID | 1.60 | 0.00 | 01-JAN-00:10 | 15355.89 | 09-JAN-06:10 |
Cooling:EnergyTransfer:Zone:CORE_MID | 138.70 | 0.00 | 01-JAN-00:10 | 20366.01 | 05-SEP-07:30 |
General:Cooling:EnergyTransfer:Zone:CORE_MID | 138.70 | 0.00 | 01-JAN-00:10 | 20366.01 | 05-SEP-07:30 |
EnergyTransfer:Zone:CORE_TOP | 133.48 | 0.00 | 01-JAN-00:10 | 24063.02 | 09-JAN-05:30 |
Heating:EnergyTransfer:Zone:CORE_TOP | 10.05 | 0.00 | 01-JAN-00:10 | 24063.02 | 09-JAN-05:30 |
General:Heating:EnergyTransfer:Zone:CORE_TOP | 10.05 | 0.00 | 01-JAN-00:10 | 24063.02 | 09-JAN-05:30 |
Cooling:EnergyTransfer:Zone:CORE_TOP | 123.43 | 0.00 | 01-JAN-00:10 | 21893.21 | 17-JUL-15:10 |
General:Cooling:EnergyTransfer:Zone:CORE_TOP | 123.43 | 0.00 | 01-JAN-00:10 | 21893.21 | 17-JUL-15:10 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 44.82 | 0.00 | 01-JAN-00:10 | 9715.45 | 09-JAN-05:20 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 20.12 | 0.00 | 01-JAN-00:10 | 9715.45 | 09-JAN-05:20 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 20.12 | 0.00 | 01-JAN-00:10 | 9715.45 | 09-JAN-05:20 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 24.70 | 0.00 | 01-JAN-00:10 | 7497.67 | 17-JUL-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 24.70 | 0.00 | 01-JAN-00:10 | 7497.67 | 17-JUL-16:00 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 42.45 | 0.00 | 01-JAN-00:10 | 10656.42 | 07-AUG-08:50 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 11.50 | 0.00 | 01-JAN-00:10 | 8101.55 | 09-JAN-05:30 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 11.50 | 0.00 | 01-JAN-00:10 | 8101.55 | 09-JAN-05:30 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 30.95 | 0.00 | 01-JAN-00:10 | 10656.42 | 07-AUG-08:50 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 30.95 | 0.00 | 01-JAN-00:10 | 10656.42 | 07-AUG-08:50 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 66.76 | 0.00 | 01-JAN-00:10 | 15011.38 | 01-SEP-13:20 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 13.89 | 0.00 | 01-JAN-00:10 | 11725.91 | 09-JAN-05:30 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 13.89 | 0.00 | 01-JAN-00:10 | 11725.91 | 09-JAN-05:30 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 52.87 | 0.00 | 01-JAN-00:10 | 15011.38 | 01-SEP-13:20 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 52.87 | 0.00 | 01-JAN-00:10 | 15011.38 | 01-SEP-13:20 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 42.65 | 0.00 | 01-JAN-00:10 | 11099.02 | 17-JUL-17:00 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 12.47 | 0.00 | 01-JAN-00:10 | 8458.67 | 09-JAN-05:30 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 12.47 | 0.00 | 01-JAN-00:10 | 8458.67 | 09-JAN-05:30 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 30.17 | 0.00 | 01-JAN-00:10 | 11099.02 | 17-JUL-17:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 30.17 | 0.00 | 01-JAN-00:10 | 11099.02 | 17-JUL-17:00 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 33.00 | 0.00 | 01-JAN-00:10 | 7417.23 | 09-JAN-05:20 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 11.13 | 0.00 | 01-JAN-00:10 | 7417.23 | 09-JAN-05:20 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 11.13 | 0.00 | 01-JAN-00:10 | 7417.23 | 09-JAN-05:20 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 21.87 | 0.00 | 01-JAN-00:10 | 5942.16 | 17-JUL-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 21.87 | 0.00 | 01-JAN-00:10 | 5942.16 | 17-JUL-16:00 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 34.12 | 0.00 | 01-JAN-00:10 | 8706.51 | 17-JUL-09:20 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 5.91 | 0.00 | 01-JAN-00:10 | 6045.60 | 09-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 5.91 | 0.00 | 01-JAN-00:10 | 6045.60 | 09-JAN-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 28.21 | 0.00 | 01-JAN-00:10 | 8706.51 | 17-JUL-09:20 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 28.21 | 0.00 | 01-JAN-00:10 | 8706.51 | 17-JUL-09:20 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 61.61 | 0.00 | 01-JAN-00:10 | 14394.31 | 09-JAN-08:00 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 22.14 | 0.00 | 01-JAN-00:10 | 14394.31 | 09-JAN-08:00 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 22.14 | 0.00 | 01-JAN-00:10 | 14394.31 | 09-JAN-08:00 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 39.48 | 0.00 | 01-JAN-00:10 | 13745.62 | 17-JUL-12:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 39.48 | 0.00 | 01-JAN-00:10 | 13745.62 | 17-JUL-12:00 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 32.77 | 0.00 | 01-JAN-00:10 | 8918.13 | 04-AUG-18:30 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 6.37 | 0.00 | 01-JAN-00:10 | 6237.07 | 09-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 6.37 | 0.00 | 01-JAN-00:10 | 6237.07 | 09-JAN-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 26.40 | 0.00 | 01-JAN-00:10 | 8918.13 | 04-AUG-18:30 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 26.40 | 0.00 | 01-JAN-00:10 | 8918.13 | 04-AUG-18:30 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 36.91 | 0.00 | 01-JAN-00:10 | 7953.12 | 09-JAN-05:20 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 9.98 | 0.00 | 01-JAN-00:10 | 7953.12 | 09-JAN-05:20 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 9.98 | 0.00 | 01-JAN-00:10 | 7953.12 | 09-JAN-05:20 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 26.93 | 0.00 | 01-JAN-00:10 | 6829.09 | 17-JUL-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 26.93 | 0.00 | 01-JAN-00:10 | 6829.09 | 17-JUL-16:00 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 38.77 | 0.00 | 01-JAN-00:10 | 10641.17 | 07-AUG-08:40 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 5.86 | 0.00 | 01-JAN-00:10 | 6678.58 | 09-JAN-05:30 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 5.86 | 0.00 | 01-JAN-00:10 | 6678.58 | 09-JAN-05:30 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 32.91 | 0.00 | 01-JAN-00:10 | 10641.17 | 07-AUG-08:40 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 32.91 | 0.00 | 01-JAN-00:10 | 10641.17 | 07-AUG-08:40 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 62.54 | 0.00 | 01-JAN-00:10 | 14349.73 | 18-OCT-13:10 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 6.26 | 0.00 | 01-JAN-00:10 | 9506.47 | 09-JAN-05:30 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 6.26 | 0.00 | 01-JAN-00:10 | 9506.47 | 09-JAN-05:30 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 56.28 | 0.00 | 01-JAN-00:10 | 14349.73 | 18-OCT-13:10 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 56.28 | 0.00 | 01-JAN-00:10 | 14349.73 | 18-OCT-13:10 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 37.99 | 0.00 | 01-JAN-00:10 | 10522.70 | 17-JUL-17:00 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 6.16 | 0.00 | 01-JAN-00:10 | 6644.38 | 09-JAN-05:30 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 6.16 | 0.00 | 01-JAN-00:10 | 6644.38 | 09-JAN-05:30 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 31.82 | 0.00 | 01-JAN-00:10 | 10522.70 | 17-JUL-17:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 31.82 | 0.00 | 01-JAN-00:10 | 10522.70 | 17-JUL-17:00 |
PlantLoopHeatingDemand:Facility | 470.45 | 0.00 | 01-JAN-00:10 | 261808.66 | 09-JAN-07:20 |
PlantLoopHeatingDemand:Plant | 56.23 | 0.00 | 01-JAN-00:10 | 7105.18 | 17-FEB-12:10 |
WaterSystems:PlantLoopHeatingDemand | 56.23 | 0.00 | 01-JAN-00:10 | 7105.18 | 17-FEB-12:10 |
General:WaterSystems:PlantLoopHeatingDemand | 56.23 | 0.00 | 01-JAN-00:10 | 7105.18 | 17-FEB-12:10 |
EnergyTransfer:HVAC | 866.25 | 0.00 | 01-JAN-00:10 | 297793.53 | 07-SEP-15:00 |
HeatingCoils:EnergyTransfer | 414.23 | 0.00 | 01-JAN-00:10 | 259499.12 | 09-JAN-07:20 |
PlantLoopHeatingDemand:HVAC | 414.23 | 0.00 | 01-JAN-00:10 | 259499.12 | 09-JAN-07:20 |
HeatingCoils:PlantLoopHeatingDemand | 414.23 | 0.00 | 01-JAN-00:10 | 259499.12 | 09-JAN-07:20 |
CoolingCoils:EnergyTransfer | 452.03 | 0.00 | 01-JAN-00:10 | 297790.32 | 07-SEP-15:00 |
EnergyTransfer:Plant | 467.45 | 0.00 | 01-JAN-00:10 | 260496.63 | 09-JAN-07:20 |
WaterSystems:EnergyTransfer | 56.23 | 0.00 | 01-JAN-00:10 | 7105.18 | 17-FEB-12:10 |
WaterUse:WaterSystems:EnergyTransfer | 56.23 | 0.00 | 01-JAN-00:10 | 7105.18 | 17-FEB-12:10 |
Boilers:EnergyTransfer | 411.23 | 0.00 | 01-JAN-00:10 | 258187.09 | 09-JAN-07:20 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
CORE_BOTTOM | 0.000 | 0.000 | 0.013 | -213.510 | 0.000 | 0.000 | 33.071 | 71.928 | 250.423 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -141.926 |
CORE_MID | 0.000 | 0.000 | 1.600 | -138.697 | 0.000 | 0.000 | 34.397 | 71.928 | 115.425 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -84.654 |
CORE_TOP | 0.000 | 0.000 | 10.053 | -123.425 | 0.000 | 0.000 | 35.321 | 71.928 | 115.425 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -109.303 |
PERIMETER_TOP_ZN_3 | 0.000 | 0.000 | 20.119 | -24.699 | 0.000 | 0.000 | 7.657 | 8.910 | 24.333 | 17.980 | 0.000 | 0.050 | 0.000 | 0.000 | -40.687 | 0.000 | -5.180 | -8.481 |
PERIMETER_TOP_ZN_2 | 0.000 | 0.000 | 11.499 | -30.952 | 0.000 | 0.000 | 4.794 | 5.547 | 15.404 | 39.928 | 0.000 | 0.033 | 0.001 | 0.000 | -25.569 | 0.000 | -3.505 | -17.178 |
PERIMETER_TOP_ZN_1 | 0.000 | 0.000 | 13.888 | -52.871 | 0.000 | 0.000 | 7.451 | 8.666 | 24.332 | 86.035 | 0.000 | 0.047 | 0.003 | 0.000 | -38.424 | 0.000 | -5.442 | -43.683 |
PERIMETER_TOP_ZN_4 | 0.000 | 0.000 | 12.473 | -30.172 | 0.000 | 0.000 | 4.877 | 5.568 | 15.403 | 38.197 | 0.000 | 0.033 | 0.000 | 0.000 | -26.846 | 0.000 | -3.512 | -16.022 |
PERIMETER_BOT_ZN_3 | 0.000 | 0.000 | 11.132 | -21.865 | 0.000 | 0.000 | 7.634 | 8.879 | 24.333 | 18.304 | 0.000 | 0.029 | 0.000 | 0.000 | -41.856 | 0.000 | -2.876 | -3.714 |
PERIMETER_BOT_ZN_2 | 0.000 | 0.000 | 5.907 | -28.215 | 0.000 | 0.000 | 4.743 | 5.534 | 15.404 | 40.009 | 0.000 | 0.018 | 0.000 | 0.000 | -26.750 | 0.000 | -1.979 | -14.671 |
PERIMETER_BOT_ZN_1 | 0.000 | 0.000 | 22.136 | -39.478 | 0.000 | 0.000 | 7.603 | 8.648 | 24.332 | 86.758 | 0.000 | 1.210 | 0.001 | 0.000 | -40.253 | 0.000 | -42.306 | -28.652 |
PERIMETER_BOT_ZN_4 | 0.000 | 0.000 | 6.365 | -26.402 | 0.000 | 0.000 | 4.809 | 5.554 | 15.403 | 38.370 | 0.000 | 0.018 | 0.002 | 0.000 | -28.048 | 0.000 | -1.981 | -14.088 |
PERIMETER_MID_ZN_3 | 0.000 | 0.000 | 9.981 | -26.927 | 0.000 | 0.000 | 7.546 | 8.910 | 24.333 | 17.632 | 0.000 | 0.042 | 5.744 | 0.000 | -42.709 | 0.000 | -4.551 | -0.000 |
PERIMETER_MID_ZN_2 | 0.000 | 0.000 | 5.856 | -32.914 | 0.000 | 0.000 | 3.516 | 5.547 | 15.404 | 39.663 | 0.000 | 0.028 | 0.002 | 0.000 | -26.749 | 0.000 | -3.069 | -7.282 |
PERIMETER_MID_ZN_1 | 0.000 | 0.000 | 6.258 | -56.279 | 0.000 | 0.000 | 7.333 | 8.666 | 24.332 | 85.615 | 0.000 | 0.040 | 0.002 | 0.000 | -40.344 | 0.000 | -4.778 | -30.842 |
PERIMETER_MID_ZN_4 | 0.000 | 0.000 | 6.164 | -31.822 | 0.000 | 0.000 | 4.810 | 5.568 | 15.403 | 37.973 | 0.000 | 0.027 | 0.000 | 0.000 | -28.144 | 0.000 | -3.080 | -6.901 |
TOPFLOOR_PLENUM | 31.810 | -26.270 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.051 | 2.335 | 0.000 | 0.000 | 0.000 | -7.926 | -0.004 |
MIDFLOOR_PLENUM | 12.713 | -14.487 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.061 | 9.542 | 0.000 | 0.000 | 0.000 | -7.830 | -0.001 |
FIRSTFLOOR_PLENUM | 7.584 | -19.071 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.046 | 17.797 | 0.000 | 0.000 | 0.000 | -6.355 | -0.000 |
Total Facility | 52.107 | -59.829 | 143.443 | -878.228 | 0.000 | 0.000 | 175.563 | 301.782 | 719.689 | 546.464 | 0.000 | 1.733 | 35.428 | 0.000 | -406.379 | 0.000 | -104.368 | -527.401 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
CORE_BOTTOM | 30-MAY-05:12 | 0.00 | 0.00 | 0.00 | -40992.46 | 0.00 | 0.00 | 315.91 | 715.98 | 7410.35 | 0.00 | 0.00 | 0.00 | 32550.22 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 17-JUL-06:03 | 0.00 | 0.00 | 0.00 | -31375.70 | 0.00 | 0.00 | 685.36 | 2148.02 | 3025.92 | 0.00 | 0.00 | 0.00 | 25516.40 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 05-SEP-06:03 | 0.00 | 0.00 | 0.00 | -31943.95 | 0.00 | 0.00 | 688.75 | 2148.02 | 3025.92 | 0.00 | 0.00 | 0.00 | 26081.25 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 16-JUL-18:31 | 0.00 | 0.00 | 0.00 | -11965.25 | 0.00 | 0.00 | 0.00 | 36.00 | 386.10 | 4366.74 | 0.00 | 53.42 | 7122.99 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 06-AUG-09:31 | 0.00 | 0.00 | 0.00 | -15859.21 | 0.00 | 0.00 | 11.19 | 22.79 | 302.86 | 11841.63 | 0.00 | 10.92 | 3669.82 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 03-SEP-12:52 | 0.00 | 0.00 | 0.00 | -20915.02 | 0.00 | 0.00 | 17.71 | 36.00 | 478.41 | 17860.51 | 0.00 | 160.18 | 2362.22 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 16-JUL-17:11 | 0.00 | 0.00 | 0.00 | -17923.66 | 0.00 | 0.00 | 0.00 | 22.79 | 244.42 | 13843.71 | 0.00 | 26.29 | 3786.45 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 16-JUL-18:21 | 0.00 | 0.00 | 0.00 | -8618.24 | 0.00 | 0.00 | 0.00 | 36.00 | 386.10 | 4758.52 | 0.00 | 28.35 | 3409.27 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 16-JUL-09:01 | 0.00 | 0.00 | 0.00 | -13360.25 | 0.00 | 0.00 | 14.48 | 22.79 | 302.86 | 11863.86 | 0.00 | 0.00 | 1191.18 | 0.00 | -0.00 | 0.00 | -34.93 | 0.00 |
PERIMETER_BOT_ZN_1 | 04-SEP-14:51 | 0.00 | 0.00 | 0.00 | -17078.48 | 0.00 | 0.00 | 21.80 | 36.00 | 478.41 | 12918.70 | 0.00 | 26.06 | 3597.51 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 16-JUL-18:21 | 0.00 | 0.00 | 0.00 | -15123.61 | 0.00 | 0.00 | 0.00 | 22.79 | 244.42 | 12423.54 | 0.00 | 9.32 | 2423.54 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 16-JUL-18:21 | 0.00 | 0.00 | 0.00 | -10512.80 | 0.00 | 0.00 | 0.00 | 36.00 | 386.10 | 4653.50 | 0.00 | 38.45 | 5398.74 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 02-JUL-09:01 | 0.00 | 0.00 | 0.00 | -17101.82 | 0.00 | 0.00 | 11.93 | 22.79 | 302.86 | 12072.31 | 0.00 | 0.00 | 4749.69 | 0.00 | -0.00 | 0.00 | -57.76 | 0.00 |
PERIMETER_MID_ZN_1 | 04-SEP-14:51 | 0.00 | 0.00 | 0.00 | -19595.40 | 0.00 | 0.00 | 20.31 | 36.00 | 478.41 | 12842.17 | 0.00 | 36.65 | 6181.86 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 16-JUL-17:01 | 0.00 | 0.00 | 0.00 | -18088.71 | 0.00 | 0.00 | 0.00 | 22.79 | 244.42 | 14031.85 | 0.00 | 14.32 | 3775.34 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 17-JUL-15:00 | 0.00 | -13034.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13034.91 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 17-JUL-15:30 | 0.00 | -6170.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.64 | 6139.32 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 17-JUL-16:00 | 0.00 | -6399.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.26 | 6348.05 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 17-JUL-15:30 | 0.00 | -25164.19 | 0.00 | -162195.69 | 0.00 | 0.00 | 17713.29 | 25681.07 | 41670.51 | 78761.25 | 0.00 | 1427.07 | 22106.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
CORE_BOTTOM | 09-JAN-06:02 | 0.00 | 0.00 | 6761.04 | 0.00 | 0.00 | 0.00 | 467.70 | 211.73 | 7410.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -14850.82 |
CORE_MID | 09-JAN-05:11 | 0.00 | 0.00 | 17872.35 | 0.00 | 0.00 | 0.00 | 0.00 | 211.73 | 2442.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -20526.14 |
CORE_TOP | 31-DEC-22:12 | 0.00 | 0.00 | 26839.29 | 0.00 | 0.00 | 0.00 | 0.00 | 211.73 | 1831.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -28882.57 |
PERIMETER_TOP_ZN_3 | 30-JAN-04:52 | 0.00 | 0.00 | 10733.76 | 0.00 | 0.00 | 0.00 | 0.00 | 44.64 | 514.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3538.88 | 0.00 | -796.95 | -6957.36 |
PERIMETER_TOP_ZN_2 | 30-JAN-04:52 | 0.00 | 0.00 | 9864.77 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 325.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2359.61 | 0.00 | -536.94 | -7322.37 |
PERIMETER_TOP_ZN_1 | 31-DEC-08:12 | 0.00 | 0.00 | 13900.65 | 0.00 | 0.00 | 0.00 | 60.58 | 75.47 | 478.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -4334.91 | 0.00 | -705.08 | -9475.11 |
PERIMETER_TOP_ZN_4 | 30-JAN-04:52 | 0.00 | 0.00 | 10514.63 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 325.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2432.31 | 0.00 | -538.87 | -7897.59 |
PERIMETER_BOT_ZN_3 | 29-JAN-22:12 | 0.00 | 0.00 | 8012.35 | 0.00 | 0.00 | 0.00 | 0.00 | 44.64 | 386.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -4663.99 | 0.00 | -328.10 | -3450.99 |
PERIMETER_BOT_ZN_2 | 08-JAN-18:32 | 0.00 | 0.00 | 7417.13 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 244.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3133.37 | 0.00 | -136.79 | -4419.66 |
PERIMETER_BOT_ZN_1 | 11-JAN-07:10 | 0.00 | 0.00 | 14558.17 | 0.00 | 0.00 | 0.00 | 218.93 | 452.82 | 637.88 | 0.00 | 0.00 | 0.00 | 17877.83 | 0.00 | -4890.21 | 0.00 | -28855.43 | 0.00 |
PERIMETER_BOT_ZN_4 | 08-JAN-18:32 | 0.00 | 0.00 | 7741.97 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 244.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3070.35 | 0.00 | -137.08 | -4807.21 |
PERIMETER_MID_ZN_3 | 08-JAN-18:32 | 0.00 | 0.00 | 8623.36 | 0.00 | 0.00 | 0.00 | 0.00 | 44.64 | 386.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -4590.07 | 0.00 | -317.47 | -4146.57 |
PERIMETER_MID_ZN_2 | 08-JAN-18:32 | 0.00 | 0.00 | 8351.60 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 244.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3131.01 | 0.00 | -212.90 | -5280.37 |
PERIMETER_MID_ZN_1 | 09-JAN-05:11 | 0.00 | 0.00 | 11186.81 | 0.00 | 0.00 | 0.00 | 0.00 | 44.64 | 514.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -4543.42 | 0.00 | -392.94 | -6809.88 |
PERIMETER_MID_ZN_4 | 08-JAN-18:32 | 0.00 | 0.00 | 8560.59 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 244.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3060.44 | 0.00 | -213.37 | -5559.46 |
TOPFLOOR_PLENUM | 11-JAN-06:09 | 19258.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -27.95 | -19230.68 |
MIDFLOOR_PLENUM | 09-JAN-08:23 | 10203.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -48.86 | -10154.62 |
FIRSTFLOOR_PLENUM | 06-NOV-06:01 | 6360.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -67.22 | -6292.78 |
Total Facility | 09-JAN-06:02 | 29278.92 | 0.00 | 144803.33 | 0.00 | 0.00 | 0.00 | 2507.66 | 1072.56 | 19712.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -47599.78 | 0.00 | -6440.01 | -143335.04 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PACU_VAV_BOT | 6.4382 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 5.6511 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_MID | 6.4059 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 5.3412 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_TOP | 6.8113 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 6.1213 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PACU_VAV_BOT | 3.2191 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.5158 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_MID | 3.2030 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.5972 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_TOP | 3.4057 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.6657 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
CORE_BOTTOM | PACU_VAV_BOT | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORE_MID | PACU_VAV_MID | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORE_TOP | PACU_VAV_TOP | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PACU_VAV_BOT | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 | |
PACU_VAV_MID | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 | |
PACU_VAV_TOP | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
CORE_BOTTOM | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 3.0992 | 3.0992 | 0.8058 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_MID | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.5253 | 2.5253 | 0.7955 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_TOP | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.6382 | 2.6382 | 0.8205 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.8122 | 0.8122 | 0.1730 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.9774 | 0.9774 | 0.1955 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.2884 | 1.2884 | 0.2577 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.0951 | 1.0951 | 0.2190 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6387 | 0.6387 | 0.1699 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.8007 | 0.8007 | 0.1601 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.0321 | 1.0321 | 0.2064 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.8676 | 0.8676 | 0.1735 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7110 | 0.7110 | 0.1678 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.9685 | 0.9685 | 0.1937 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.1836 | 1.1836 | 0.2367 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.0176 | 1.0176 | 0.2035 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PACU_VAV_BOT | 6.4382 | 5.6511 | 6.4382 | 1.5158 | 0.0000 | 1.0000 |
PACU_VAV_MID | 6.4059 | 5.3412 | 6.4059 | 1.5972 | 0.0000 | 1.0000 |
PACU_VAV_TOP | 6.8113 | 6.1213 | 6.8113 | 1.6657 | 0.0000 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
CORE_BOTTOM | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.5496 | 1.5496 | 0.8058 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_MID | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.2626 | 1.2626 | 0.7955 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_TOP | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.3191 | 1.3191 | 0.8205 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4061 | 0.4061 | 0.1730 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4887 | 0.4887 | 0.1955 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6442 | 0.6442 | 0.2577 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5475 | 0.5475 | 0.2190 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3193 | 0.3193 | 0.1699 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4003 | 0.4003 | 0.1601 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5160 | 0.5160 | 0.2064 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4338 | 0.4338 | 0.1735 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3555 | 0.3555 | 0.1678 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4842 | 0.4842 | 0.1937 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5918 | 0.5918 | 0.2367 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5088 | 0.5088 | 0.2035 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PACU_VAV_BOT | 3.2191 | 1.5158 | 1.5158 | 1.5158 | 0.0000 | 1.0000 |
PACU_VAV_MID | 3.2030 | 1.5972 | 1.5972 | 1.5972 | 0.0000 | 1.0000 |
PACU_VAV_TOP | 3.4057 | 1.6657 | 1.6657 | 1.6657 | 0.0000 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Great Falls Intl Arpt MT USA TMY3 WMO#=727750 |
Total gross floor area [m2] | 4982.19 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
CORE_BOTTOM | 983.54 | 983.54 | 0.00 | 113.98 |
CORE_MID | 983.54 | 983.54 | 0.00 | 113.98 |
CORE_TOP | 983.54 | 983.54 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_2 | 131.26 | 131.26 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_2 | 131.26 | 131.26 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
PERIMETER_MID_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_MID_ZN_2 | 131.26 | 131.26 | 0.00 | 96.54 |
PERIMETER_MID_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_MID_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
TOPFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
Totals | 4982.19 | 4982.19 | 0.00 |
Data | |
Number of hours heating loads not met | 438.50 |
Number of hours cooling loads not met | 104.50 |
Number of hours not met | 543.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heating -- Boiler | 0.00 | 0.00 | 588.15 | 326022.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heating -- Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- General | 106.54 | 75865.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 301.78 | 32642.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 51.81 | 5686.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ElevatorLift | 134.36 | 7125.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ElevatorLightsFan | 0.64 | 86.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 584.69 | 34487.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Transformer | 26.90 | 1410.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 107.32 | 36534.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- General | 2.93 | 1064.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 59.04 | 7227.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 719.69 | 1376.01 |
Natural Gas | 0.00 | 588.15 |
Additional | 0.00 | 0.00 |
Total | 719.69 | 1964.16 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 60.57 |
Space Heating | 0.00 |
Space Cooling | 21.38 |
Fans (All) | 21.54 |
Service Water Heating | 11.85 |
Receptacle Equipment | 144.45 |
Miscellaneous (All) | 276.19 |
Subtotal | 276.19 |
Natural Gas [MJ/m2] | |
Space Heating | 118.05 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 118.05 |
Subtotal | 118.05 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 15.36 |
Space Heating | 29.94 |
Space Cooling | 5.42 |
Fans (All) | 5.46 |
Service Water Heating | 3.01 |
Receptacle Equipment | 36.64 |
Miscellaneous | 4.16 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
ELEVATOR_RUNNING_SCH | 145. | 3744. |
ELEVATOR_STANDBY_SCH | 8276. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4472. | 4472. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 6752. | 8760. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6828. | 8760. |
ALWAYS_OFF | 0. | 0. |
LTG_SCH_OFFICE | 2460. | 8760. |
BLDG_EQUIP_SCH | 4095. | 8760. |
BLDG_OCC_SCH | 2528. | 5992. |
BLDG_OCC_SCH_W_SB | 1878. | 5056. |
BLDG_OCC_SCH_WO_SB | 2545. | 5992. |
ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
ELEV_LIGHT_FAN_SCH_ADD_DF | 1470. | 4212. |
BLDG_SWH_SCH | 1441. | 5992. |
WORK_EFF_SCH | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4472. | 4472. |
MINOA_SCHED | 8760. | 8760. |
CORE_BOTTOM SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_BOTTOM SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
CORE_MID SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_MID SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
CORE_TOP SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_TOP SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
INFIL_SCH_PNNL | 5172. | 8760. |
INFIL_DOOR_OPENING_SCH | 1121. | 3380. |
PERIMETER_MID_ZN_2_OA_MULT | 7824. | 7824. |
PERIMETER_MID_ZN_2_MDP_SCH | 1574. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_SCH_YES_OPTIMUM | CORE_BOTTOM DUAL SP CONTROL | January | 21.00 | 365 | 15.60 | 365 |
CLGSETP_SCH_YES_OPTIMUM | CORE_BOTTOM DUAL SP CONTROL | July | 24.00 | 365 | 26.70 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Heat Index HoursSafe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
CORE_BOTTOM | 8725.33 | 34.67 | 0.00 | 0.00 | 0.00 |
CORE_MID | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 8758.50 | 1.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 8742.83 | 17.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 8743.17 | 16.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 8740.17 | 19.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 8745.33 | 14.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 8749.67 | 10.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 8745.33 | 14.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 8758.83 | 1.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 8740.67 | 19.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 8742.50 | 17.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 8740.33 | 19.67 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 8714.67 | 45.33 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 8714.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 8760.00 | 45.33 | 0.00 | 0.00 | 0.00 |
Average | 8747.07 | 12.93 | 0.00 | 0.00 | 0.00 |
Sum | 157447.33 | 232.67 | 0.00 | 0.00 | 0.00 |
Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
CORE_BOTTOM | 128280.67 | 23.33 | 0.00 | 0.00 | 0.00 |
CORE_MID | 128304.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 128304.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 10134.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 128304.00 | 23.33 | 0.00 | 0.00 | 0.00 |
Average | 34142.04 | 1.30 | 0.00 | 0.00 | 0.00 |
Sum | 614556.67 | 23.33 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
CORE_BOTTOM | 8681.00 | 79.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 8750.17 | 9.83 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 8756.50 | 3.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 8758.83 | 1.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 8750.33 | 9.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 8753.50 | 6.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 8752.00 | 8.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 8757.67 | 2.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 8750.50 | 9.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 8748.67 | 11.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 8746.33 | 13.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 8758.00 | 2.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 8750.17 | 9.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 8749.00 | 11.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 8748.00 | 12.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 8748.50 | 11.50 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 8681.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 8760.00 | 79.00 | 0.00 | 0.00 | 0.00 |
Average | 8748.84 | 11.16 | 0.00 | 0.00 | 0.00 |
Sum | 157479.17 | 200.83 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
CORE_BOTTOM | 128245.83 | 58.17 | 0.00 | 0.00 | 0.00 |
CORE_MID | 128288.67 | 15.33 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 128297.00 | 7.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 10134.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 128297.00 | 58.17 | 0.00 | 0.00 | 0.00 |
Average | 34138.86 | 4.47 | 0.00 | 0.00 | 0.00 |
Sum | 614499.50 | 80.50 | 0.00 | 0.00 | 0.00 |
SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
None |
SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
CO2 Level HoursSafe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:12
Illuminance Level HoursA Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
CORE_BOTTOM | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 0.00 | 8760.00 | 0.00 |
Average | 0.00 | 0.00 | 5840.00 | 0.00 |
Sum | 0.00 | 0.00 | 105120.00 | 0.00 |
A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
CORE_BOTTOM | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_MID_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_MID_ZN_2 | 0.00 | 0.00 | 10134.00 | 0.00 |
PERIMETER_MID_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_MID_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 0.00 | 24909.00 | 0.00 |
Average | 0.00 | 0.00 | 12759.33 | 0.00 |
Sum | 0.00 | 0.00 | 229668.00 | 0.00 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 6B
For: Environment
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
For: Environment
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2016
For: Environment
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICEMEDIUM
For: Environment
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MT_GREATFALLS
For: Environment
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PERFORMANCEPATHPROPOSED
For: Environment
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | -8.80 |
February | -2.17 |
March | 0.301 |
April | 6.668 |
May | 10.099 |
June | 16.456 |
July | 20.571 |
August | 19.174 |
September | 14.689 |
October | 8.635 |
November | 2.839 |
December | -4.07 |
Annual Sum or Average | 7.074 |
Minimum of Months | -8.80 |
Maximum of Months | 20.571 |
Report: ZoneCoolingSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.946776E+10 | 9950.03 | 19-JAN-16:40 | -6.1 | -7.8 | 0.181163E+10 | 2606.56 | 19-JAN-14:00 | -6.1 | -7.8 |
February | 0.993277E+10 | 17166.31 | 28-FEB-17:00 | 10.00 | 4.31 | 0.172499E+10 | 2606.63 | 28-FEB-10:09 | 10.00 | 4.31 |
March | 0.139140E+11 | 17441.30 | 01-MAR-17:00 | 7.80 | 3.22 | 0.212435E+10 | 2606.64 | 01-MAR-10:09 | 7.80 | 3.22 |
April | 0.156179E+11 | 25152.19 | 25-APR-05:03 | 1.10 | -0.7 | 0.191167E+10 | 2606.64 | 04-APR-09:09 | 1.10 | -0.7 |
May | 0.192615E+11 | 40985.52 | 30-MAY-05:12 | 15.60 | 11.34 | 0.207604E+10 | 2606.83 | 02-MAY-13:09 | 15.60 | 11.34 |
June | 0.250520E+11 | 39789.25 | 23-JUN-05:12 | 17.97 | 11.79 | 0.207171E+10 | 2606.66 | 20-JUN-09:00 | 17.97 | 11.79 |
July | 0.266669E+11 | 40965.23 | 24-JUL-05:12 | 13.73 | 10.06 | 0.192729E+10 | 2606.72 | 13-JUL-09:00 | 13.73 | 10.06 |
August | 0.276486E+11 | 39816.40 | 15-AUG-05:12 | 13.90 | 8.81 | 0.216295E+10 | 2606.67 | 24-AUG-09:00 | 20.00 | 12.25 |
September | 0.230118E+11 | 39510.36 | 01-SEP-05:12 | 17.03 | 10.83 | 0.191940E+10 | 2606.72 | 07-SEP-09:00 | 16.70 | 15.61 |
October | 0.187749E+11 | 36698.11 | 19-OCT-06:02 | 12.02 | 5.45 | 0.199225E+10 | 2606.63 | 06-OCT-09:50 | 12.02 | 5.45 |
November | 0.136726E+11 | 28911.82 | 06-NOV-06:01 | -3.5 | -4.3 | 0.195309E+10 | 2606.65 | 16-NOV-14:09 | 10.63 | 6.46 |
December | 0.104898E+11 | 13967.30 | 07-DEC-16:10 | 6.32 | 2.06 | 0.184748E+10 | 2606.64 | 07-DEC-10:09 | 6.32 | 2.06 |
Annual Sum or Average | 0.213511E+12 | 0.235229E+11 | ||||||||
Minimum of Months | 0.946776E+10 | 9950.03 | -6.1 | -7.8 | 0.172499E+10 | 2606.56 | -6.1 | -7.8 | ||
Maximum of Months | 0.276486E+11 | 40985.52 | 17.97 | 11.79 | 0.216295E+10 | 2606.83 | 20.00 | 15.61 |
Report: ZoneCoolingSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 1948000.52 | 346.54 | 14-JAN-13:40 | 9.80 | 4.59 | 0.00 | 0.00 | 01-JAN-00:10 | 9.80 | 4.59 |
February | 0.117175E+09 | 2315.62 | 26-FEB-14:16 | 15.97 | 6.00 | 0.00 | 0.00 | 01-FEB-00:10 | 15.97 | 6.00 |
March | 0.446808E+09 | 2576.78 | 22-MAR-16:10 | 11.10 | 4.35 | 0.00 | 0.00 | 01-MAR-00:10 | 11.10 | 4.35 |
April | 0.124418E+10 | 6096.98 | 25-APR-15:10 | 17.13 | 7.50 | 0.00 | 0.00 | 01-APR-00:10 | 17.13 | 7.50 |
May | 0.258751E+10 | 9189.00 | 19-MAY-15:00 | 28.30 | 14.88 | 0.00 | 0.00 | 01-MAY-00:10 | 28.30 | 14.88 |
June | 0.522346E+10 | 10485.93 | 23-JUN-13:30 | 31.40 | 15.21 | 0.00 | 0.00 | 01-JUN-00:10 | 31.40 | 15.21 |
July | 0.691773E+10 | 13035.23 | 17-JUL-15:00 | 36.10 | 17.00 | 0.00 | 0.00 | 01-JUL-00:10 | 36.10 | 17.00 |
August | 0.593217E+10 | 11773.08 | 07-AUG-15:30 | 32.50 | 16.07 | 0.00 | 0.00 | 01-AUG-00:10 | 32.50 | 16.07 |
September | 0.286541E+10 | 8769.81 | 05-SEP-14:20 | 24.40 | 15.02 | 0.00 | 0.00 | 01-SEP-00:10 | 24.40 | 15.02 |
October | 0.853727E+09 | 5603.51 | 18-OCT-15:20 | 24.80 | 11.42 | 0.00 | 0.00 | 01-OCT-00:10 | 24.80 | 11.42 |
November | 80794942.52 | 1416.25 | 03-NOV-13:50 | 14.78 | 7.82 | 0.00 | 0.00 | 01-NOV-00:10 | 14.78 | 7.82 |
December | 51469.51 | 106.11 | 09-DEC-17:25 | 11.15 | 3.91 | 0.00 | 0.00 | 01-DEC-00:10 | 11.15 | 3.91 |
Annual Sum or Average | 0.262710E+11 | 0.00 | ||||||||
Minimum of Months | 51469.51 | 106.11 | 9.80 | 3.91 | 0.00 | 0.00 | 9.80 | 3.91 | ||
Maximum of Months | 0.691773E+10 | 13035.23 | 36.10 | 17.00 | 0.00 | 0.00 | 36.10 | 17.00 |
Report: ZoneCoolingSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 32562453.32 | 3795.68 | 26-JAN-05:01 | -22.2 | -22.7 | 0.00 | 0.00 | 01-JAN-00:10 | -22.2 | -22.7 |
February | 46693180.20 | 3873.50 | 04-FEB-05:01 | -20.4 | -20.8 | 0.00 | 0.00 | 01-FEB-00:10 | -20.4 | -20.8 |
March | 0.169449E+09 | 2957.52 | 03-MAR-06:01 | -12.8 | -13.7 | 0.00 | 0.00 | 01-MAR-00:10 | -12.8 | -13.7 |
April | 0.445617E+09 | 2740.71 | 11-APR-06:02 | 0.73 | -2.3 | 0.00 | 0.00 | 01-APR-00:10 | 0.73 | -2.3 |
May | 0.974187E+09 | 3236.05 | 19-MAY-16:00 | 27.80 | 14.54 | 0.00 | 0.00 | 01-MAY-00:10 | 27.80 | 14.54 |
June | 0.282454E+10 | 4407.61 | 23-JUN-15:30 | 27.50 | 14.33 | 0.00 | 0.00 | 01-JUN-00:10 | 27.50 | 14.33 |
July | 0.394185E+10 | 6171.05 | 17-JUL-15:30 | 36.65 | 17.14 | 0.00 | 0.00 | 01-JUL-00:10 | 36.65 | 17.14 |
August | 0.359073E+10 | 6163.94 | 07-AUG-15:30 | 32.50 | 16.07 | 0.00 | 0.00 | 01-AUG-00:10 | 32.50 | 16.07 |
September | 0.179115E+10 | 5656.49 | 05-SEP-06:10 | 18.90 | 13.05 | 0.00 | 0.00 | 01-SEP-00:10 | 18.90 | 13.05 |
October | 0.504660E+09 | 2133.81 | 04-OCT-06:03 | 0.00 | -0.5 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | -0.5 |
November | 0.142884E+09 | 2633.92 | 09-NOV-07:02 | -1.5 | -2.5 | 0.00 | 0.00 | 01-NOV-00:10 | -1.5 | -2.5 |
December | 22792493.99 | 3285.04 | 29-DEC-05:01 | -25.0 | -25.3 | 0.00 | 0.00 | 01-DEC-00:10 | -25.0 | -25.3 |
Annual Sum or Average | 0.144871E+11 | 0.00 | ||||||||
Minimum of Months | 22792493.99 | 2133.81 | -25.0 | -25.3 | 0.00 | 0.00 | -25.0 | -25.3 | ||
Maximum of Months | 0.394185E+10 | 6171.05 | 36.65 | 17.14 | 0.00 | 0.00 | 36.65 | 17.14 |
Report: ZoneCoolingSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.106573E+09 | 3668.93 | 28-JAN-05:01 | -27.5 | -27.9 | 0.00 | 0.00 | 01-JAN-00:10 | -27.5 | -27.9 |
February | 0.166433E+09 | 3517.90 | 04-FEB-05:01 | -20.4 | -20.8 | 0.00 | 0.00 | 01-FEB-00:10 | -20.4 | -20.8 |
March | 0.365430E+09 | 3431.01 | 03-MAR-17:10 | -14.4 | -15.2 | 0.00 | 0.00 | 01-MAR-00:10 | -14.4 | -15.2 |
April | 0.806857E+09 | 3454.21 | 12-APR-06:02 | -0.9 | -2.6 | 0.00 | 0.00 | 01-APR-00:10 | -0.9 | -2.6 |
May | 0.144048E+10 | 3525.00 | 30-MAY-06:15 | 15.40 | 11.37 | 0.00 | 0.00 | 01-MAY-00:10 | 15.40 | 11.37 |
June | 0.338005E+10 | 4625.79 | 23-JUN-15:30 | 27.50 | 14.33 | 0.00 | 0.00 | 01-JUN-00:10 | 27.50 | 14.33 |
July | 0.450873E+10 | 6399.32 | 17-JUL-16:00 | 37.20 | 17.28 | 0.00 | 0.00 | 01-JUL-00:10 | 37.20 | 17.28 |
August | 0.432536E+10 | 6132.49 | 07-AUG-16:00 | 32.20 | 16.16 | 0.00 | 0.00 | 01-AUG-00:10 | 32.20 | 16.16 |
September | 0.251455E+10 | 5883.55 | 05-SEP-06:10 | 18.90 | 13.05 | 0.00 | 0.00 | 01-SEP-00:10 | 18.90 | 13.05 |
October | 0.105234E+10 | 3013.74 | 06-OCT-06:02 | -0.9 | -1.3 | 0.00 | 0.00 | 01-OCT-00:10 | -0.9 | -1.3 |
November | 0.286690E+09 | 2999.89 | 10-NOV-07:02 | -4.5 | -5.4 | 0.00 | 0.00 | 01-NOV-00:10 | -4.5 | -5.4 |
December | 0.117946E+09 | 3405.28 | 29-DEC-05:01 | -25.0 | -25.3 | 0.00 | 0.00 | 01-DEC-00:10 | -25.0 | -25.3 |
Annual Sum or Average | 0.190714E+11 | 0.00 | ||||||||
Minimum of Months | 0.106573E+09 | 2999.89 | -27.5 | -27.9 | 0.00 | 0.00 | -27.5 | -27.9 | ||
Maximum of Months | 0.450873E+10 | 6399.32 | 37.20 | 17.28 | 0.00 | 0.00 | 37.20 | 17.28 |
Report: ZoneCoolingSummaryMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.542502E+10 | 6167.90 | 13-JAN-16:50 | 7.98 | 4.06 | 0.155474E+10 | 2272.94 | 13-JAN-16:00 | 7.80 | 3.93 |
February | 0.641986E+10 | 9670.20 | 28-FEB-17:00 | 10.00 | 4.31 | 0.151812E+10 | 2606.35 | 28-FEB-14:00 | 10.00 | 4.31 |
March | 0.885916E+10 | 9607.38 | 01-MAR-17:00 | 7.80 | 3.22 | 0.194493E+10 | 2606.59 | 02-MAR-14:20 | 10.77 | 4.53 |
April | 0.995935E+10 | 13138.63 | 25-APR-16:00 | 17.80 | 7.70 | 0.184060E+10 | 2606.62 | 13-APR-09:09 | 17.80 | 7.70 |
May | 0.123069E+11 | 22405.55 | 30-MAY-05:12 | 15.60 | 11.34 | 0.201373E+10 | 2606.67 | 04-MAY-13:09 | 15.60 | 11.34 |
June | 0.174945E+11 | 29305.31 | 26-JUN-06:02 | 13.03 | 10.64 | 0.206198E+10 | 2606.65 | 20-JUN-09:00 | 13.03 | 10.64 |
July | 0.191360E+11 | 31376.76 | 17-JUL-06:03 | 19.05 | 13.84 | 0.192123E+10 | 2606.69 | 13-JUL-09:00 | 19.05 | 13.84 |
August | 0.191792E+11 | 30894.40 | 07-AUG-06:03 | 19.45 | 10.91 | 0.215572E+10 | 2606.65 | 01-AUG-13:09 | 19.45 | 10.91 |
September | 0.146056E+11 | 31042.92 | 05-SEP-06:03 | 18.90 | 13.05 | 0.190071E+10 | 2606.70 | 07-SEP-09:00 | 16.70 | 15.61 |
October | 0.108623E+11 | 13815.60 | 18-OCT-16:00 | 24.40 | 11.02 | 0.193121E+10 | 2606.62 | 20-OCT-09:09 | 7.98 | 4.07 |
November | 0.802920E+10 | 10203.65 | 03-NOV-16:00 | 14.30 | 7.69 | 0.177022E+10 | 2606.58 | 09-NOV-14:09 | 9.33 | 4.09 |
December | 0.642020E+10 | 6930.72 | 07-DEC-16:20 | 5.93 | 1.89 | 0.158349E+10 | 2512.33 | 07-DEC-14:00 | 5.93 | 1.89 |
Annual Sum or Average | 0.138697E+12 | 0.221967E+11 | ||||||||
Minimum of Months | 0.542502E+10 | 6167.90 | 5.93 | 1.89 | 0.151812E+10 | 2272.94 | 5.93 | 1.89 | ||
Maximum of Months | 0.191792E+11 | 31376.76 | 24.40 | 13.84 | 0.215572E+10 | 2606.70 | 19.45 | 15.61 |
Report: ZoneCoolingSummaryMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.311665E+10 | 6099.79 | 13-JAN-16:50 | 7.98 | 4.06 | 0.147951E+10 | 2206.83 | 13-JAN-16:00 | 7.80 | 3.93 |
February | 0.462289E+10 | 7817.29 | 28-FEB-17:00 | 10.00 | 4.31 | 0.141840E+10 | 2537.84 | 28-FEB-16:00 | 10.00 | 4.31 |
March | 0.734554E+10 | 8057.57 | 29-MAR-16:00 | 12.20 | 4.07 | 0.180655E+10 | 2596.78 | 23-MAR-13:00 | 12.20 | 4.07 |
April | 0.893944E+10 | 14049.25 | 25-APR-16:00 | 17.80 | 7.70 | 0.174097E+10 | 2606.60 | 13-APR-13:00 | 17.80 | 7.70 |
May | 0.115549E+11 | 17126.25 | 19-MAY-16:00 | 27.80 | 14.54 | 0.194750E+10 | 2606.68 | 04-MAY-13:09 | 27.80 | 14.54 |
June | 0.171657E+11 | 19298.73 | 23-JUN-14:00 | 31.70 | 15.26 | 0.204953E+10 | 2606.64 | 29-JUN-09:30 | 25.55 | 12.82 |
July | 0.191851E+11 | 28776.60 | 17-JUL-06:03 | 19.05 | 13.84 | 0.191553E+10 | 2606.68 | 13-JUL-09:00 | 19.05 | 13.84 |
August | 0.185880E+11 | 28228.98 | 07-AUG-06:03 | 19.45 | 10.91 | 0.214553E+10 | 2606.65 | 01-AUG-13:09 | 19.45 | 10.91 |
September | 0.132650E+11 | 31941.21 | 05-SEP-06:03 | 18.90 | 13.05 | 0.185151E+10 | 2606.69 | 07-SEP-09:00 | 16.70 | 15.61 |
October | 0.921541E+10 | 13608.21 | 18-OCT-16:00 | 24.40 | 11.02 | 0.181709E+10 | 2606.57 | 19-OCT-13:09 | 21.10 | 10.07 |
November | 0.630833E+10 | 8131.67 | 03-NOV-16:00 | 14.30 | 7.69 | 0.162671E+10 | 2537.85 | 03-NOV-15:00 | 14.30 | 7.69 |
December | 0.411855E+10 | 6649.44 | 06-DEC-16:20 | 8.50 | 3.80 | 0.147377E+10 | 2372.32 | 07-DEC-14:00 | 8.30 | 2.55 |
Annual Sum or Average | 0.123425E+12 | 0.212726E+11 | ||||||||
Minimum of Months | 0.311665E+10 | 6099.79 | 7.98 | 3.80 | 0.141840E+10 | 2206.83 | 7.80 | 2.55 | ||
Maximum of Months | 0.191851E+11 | 31941.21 | 31.70 | 15.26 | 0.214553E+10 | 2606.69 | 27.80 | 15.61 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 26575174.28 | 1002.18 | 13-JAN-16:30 | 8.35 | 4.30 | 0.302106E+09 | 406.84 | 26-JAN-10:00 | -21.7 | -22.3 |
February | 0.261363E+09 | 1420.03 | 27-FEB-16:10 | 17.78 | 6.92 | 0.280829E+09 | 500.24 | 27-FEB-16:30 | 15.55 | 6.44 |
March | 0.758213E+09 | 1494.31 | 29-MAR-16:00 | 12.20 | 4.07 | 0.348939E+09 | 519.81 | 29-MAR-15:00 | 12.20 | 4.07 |
April | 0.141423E+10 | 3616.99 | 07-APR-14:30 | 22.50 | 9.29 | 0.338989E+09 | 549.48 | 13-APR-13:00 | 13.30 | 7.60 |
May | 0.246313E+10 | 5439.39 | 19-MAY-16:00 | 27.80 | 14.54 | 0.391906E+09 | 549.50 | 19-MAY-13:09 | 27.80 | 14.54 |
June | 0.464071E+10 | 6509.26 | 23-JUN-13:50 | 31.60 | 15.24 | 0.427736E+09 | 549.50 | 29-JUN-09:30 | 25.55 | 12.82 |
July | 0.554130E+10 | 11965.45 | 16-JUL-18:31 | 32.40 | 17.11 | 0.403332E+09 | 549.51 | 13-JUL-09:00 | 32.40 | 17.11 |
August | 0.479422E+10 | 11664.95 | 06-AUG-16:11 | 35.40 | 16.13 | 0.446880E+09 | 549.50 | 01-AUG-13:09 | 35.40 | 16.13 |
September | 0.274924E+10 | 10762.11 | 04-SEP-15:41 | 32.70 | 16.52 | 0.373013E+09 | 549.50 | 07-SEP-09:00 | 16.70 | 15.61 |
October | 0.138765E+10 | 2862.51 | 19-OCT-14:40 | 21.50 | 10.24 | 0.351633E+09 | 549.48 | 19-OCT-13:00 | 21.50 | 10.24 |
November | 0.548608E+09 | 1360.36 | 03-NOV-16:00 | 14.30 | 7.69 | 0.313741E+09 | 491.63 | 08-NOV-14:00 | 13.20 | 7.65 |
December | 0.114309E+09 | 1111.96 | 06-DEC-16:00 | 9.40 | 4.51 | 0.294193E+09 | 429.52 | 06-DEC-14:00 | 9.40 | 4.51 |
Annual Sum or Average | 0.246996E+11 | 0.427330E+10 | ||||||||
Minimum of Months | 26575174.28 | 1002.18 | 8.35 | 4.07 | 0.280829E+09 | 406.84 | -21.7 | -22.3 | ||
Maximum of Months | 0.554130E+10 | 11965.45 | 35.40 | 17.11 | 0.446880E+09 | 549.51 | 35.40 | 17.11 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 97119481.69 | 1202.35 | 20-JAN-10:30 | -2.8 | -5.5 | 0.192894E+09 | 268.20 | 20-JAN-10:39 | -2.6 | -5.4 |
February | 0.507051E+09 | 2120.79 | 27-FEB-10:30 | 13.05 | 4.83 | 0.182702E+09 | 347.87 | 28-FEB-10:09 | 1.57 | -0.3 |
March | 0.116063E+10 | 4259.72 | 23-MAR-10:00 | 8.30 | 1.60 | 0.232009E+09 | 347.88 | 22-MAR-09:00 | 8.30 | 1.60 |
April | 0.210399E+10 | 6725.84 | 25-APR-09:20 | 10.33 | 5.07 | 0.223897E+09 | 347.88 | 24-APR-09:30 | 10.33 | 5.07 |
May | 0.316364E+10 | 8174.38 | 19-MAY-08:50 | 17.52 | 11.29 | 0.256365E+09 | 347.89 | 02-MAY-13:09 | 17.52 | 11.29 |
June | 0.542674E+10 | 12606.43 | 25-JUN-08:52 | 16.70 | 11.81 | 0.271713E+09 | 348.66 | 23-JUN-09:00 | 16.70 | 11.81 |
July | 0.655919E+10 | 15427.90 | 16-JUL-09:12 | 22.57 | 16.22 | 0.255531E+09 | 348.54 | 03-JUL-09:00 | 22.57 | 16.22 |
August | 0.589607E+10 | 15859.34 | 06-AUG-09:31 | 29.07 | 14.77 | 0.284233E+09 | 348.56 | 11-AUG-09:50 | 27.52 | 12.49 |
September | 0.334972E+10 | 11854.40 | 04-SEP-08:22 | 26.15 | 14.59 | 0.239778E+09 | 347.88 | 14-SEP-13:00 | 21.70 | 13.42 |
October | 0.176102E+10 | 4949.16 | 18-OCT-09:40 | 19.07 | 8.41 | 0.231642E+09 | 347.87 | 27-OCT-09:39 | 9.07 | 4.22 |
November | 0.733918E+09 | 2006.67 | 03-NOV-09:40 | 7.90 | 4.84 | 0.201438E+09 | 347.86 | 03-NOV-09:00 | 8.70 | 5.33 |
December | 0.193352E+09 | 1265.05 | 20-DEC-10:20 | 3.67 | -0.4 | 0.186827E+09 | 276.38 | 20-DEC-10:30 | 3.85 | -0.4 |
Annual Sum or Average | 0.309524E+11 | 0.275903E+10 | ||||||||
Minimum of Months | 97119481.69 | 1202.35 | -2.8 | -5.5 | 0.182702E+09 | 268.20 | -2.6 | -5.4 | ||
Maximum of Months | 0.655919E+10 | 15859.34 | 29.07 | 16.22 | 0.284233E+09 | 348.66 | 27.52 | 16.22 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.891561E+09 | 5969.98 | 19-JAN-13:40 | -6.0 | -7.8 | 0.326122E+09 | 549.49 | 31-JAN-14:00 | -1.1 | -4.4 |
February | 0.205926E+10 | 17321.09 | 26-FEB-14:12 | 15.97 | 6.00 | 0.318108E+09 | 549.49 | 08-FEB-14:00 | 15.97 | 6.00 |
March | 0.306747E+10 | 11938.03 | 01-MAR-13:50 | 6.52 | 2.64 | 0.382963E+09 | 549.50 | 14-MAR-13:00 | 15.00 | 6.94 |
April | 0.345458E+10 | 11506.91 | 25-APR-13:40 | 16.30 | 6.98 | 0.351038E+09 | 549.71 | 25-APR-13:39 | 16.30 | 6.98 |
May | 0.444898E+10 | 10982.75 | 19-MAY-13:30 | 26.65 | 14.96 | 0.395965E+09 | 549.53 | 02-MAY-13:09 | 26.65 | 14.96 |
June | 0.655617E+10 | 10858.28 | 30-JUN-13:30 | 28.05 | 13.89 | 0.422211E+09 | 549.50 | 29-JUN-09:30 | 28.05 | 13.89 |
July | 0.816902E+10 | 19004.40 | 16-JUL-15:12 | 33.13 | 18.76 | 0.400661E+09 | 550.12 | 18-JUL-13:00 | 31.70 | 17.43 |
August | 0.889505E+10 | 20008.08 | 06-AUG-13:32 | 34.23 | 15.17 | 0.444575E+09 | 550.20 | 31-AUG-13:39 | 25.37 | 13.99 |
September | 0.679167E+10 | 20915.07 | 03-SEP-12:52 | 33.30 | 15.94 | 0.379371E+09 | 550.22 | 05-SEP-13:00 | 24.40 | 15.14 |
October | 0.476332E+10 | 19624.38 | 15-OCT-13:52 | 23.30 | 11.17 | 0.381197E+09 | 549.73 | 18-OCT-13:00 | 25.00 | 11.40 |
November | 0.253074E+10 | 12109.11 | 03-NOV-13:30 | 14.35 | 7.74 | 0.353789E+09 | 550.00 | 03-NOV-13:00 | 15.00 | 7.85 |
December | 0.124405E+10 | 6346.43 | 06-DEC-14:30 | 11.40 | 5.46 | 0.323381E+09 | 549.49 | 12-DEC-14:00 | -2.8 | -5.6 |
Annual Sum or Average | 0.528719E+11 | 0.447938E+10 | ||||||||
Minimum of Months | 0.891561E+09 | 5969.98 | -6.0 | -7.8 | 0.318108E+09 | 549.49 | -2.8 | -5.6 | ||
Maximum of Months | 0.889505E+10 | 20915.07 | 34.23 | 18.76 | 0.444575E+09 | 550.22 | 31.70 | 17.43 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.141847E+09 | 1681.02 | 13-JAN-15:50 | 9.08 | 4.76 | 0.193521E+09 | 301.34 | 13-JAN-15:00 | 8.90 | 4.67 |
February | 0.536740E+09 | 4546.73 | 28-FEB-16:40 | 10.37 | 4.49 | 0.181949E+09 | 347.03 | 27-FEB-14:00 | 10.37 | 4.49 |
March | 0.113871E+10 | 5787.66 | 28-MAR-16:00 | 10.60 | 3.09 | 0.222772E+09 | 347.83 | 02-MAR-14:00 | 10.60 | 3.09 |
April | 0.210810E+10 | 11748.51 | 22-APR-17:05 | 16.10 | 8.62 | 0.209107E+09 | 347.84 | 07-APR-13:00 | 16.10 | 8.62 |
May | 0.338909E+10 | 16724.90 | 28-MAY-17:02 | 20.92 | 10.40 | 0.240787E+09 | 347.85 | 19-MAY-13:09 | 20.92 | 10.40 |
June | 0.508413E+10 | 16731.96 | 18-JUN-17:22 | 25.30 | 14.49 | 0.263197E+09 | 347.85 | 29-JUN-09:30 | 25.55 | 12.82 |
July | 0.597443E+10 | 17924.56 | 16-JUL-17:11 | 33.13 | 17.22 | 0.251325E+09 | 347.86 | 13-JUL-09:00 | 33.13 | 17.22 |
August | 0.540491E+10 | 17162.90 | 06-AUG-16:11 | 35.40 | 16.13 | 0.276120E+09 | 347.85 | 01-AUG-13:09 | 35.40 | 16.13 |
September | 0.347561E+10 | 17373.51 | 04-SEP-16:21 | 32.80 | 16.63 | 0.227919E+09 | 347.85 | 05-SEP-09:09 | 17.20 | 11.96 |
October | 0.189240E+10 | 6978.25 | 18-OCT-16:00 | 24.40 | 11.02 | 0.218274E+09 | 347.83 | 18-OCT-13:00 | 24.40 | 11.02 |
November | 0.782837E+09 | 3486.09 | 03-NOV-15:40 | 14.40 | 7.69 | 0.202502E+09 | 346.99 | 09-NOV-14:00 | 9.00 | 3.82 |
December | 0.243798E+09 | 1843.86 | 06-DEC-15:50 | 9.68 | 4.65 | 0.188331E+09 | 322.41 | 06-DEC-15:00 | 9.40 | 4.51 |
Annual Sum or Average | 0.301726E+11 | 0.267580E+10 | ||||||||
Minimum of Months | 0.141847E+09 | 1681.02 | 9.08 | 3.09 | 0.181949E+09 | 301.34 | 8.90 | 3.09 | ||
Maximum of Months | 0.597443E+10 | 17924.56 | 35.40 | 17.22 | 0.276120E+09 | 347.86 | 35.40 | 17.22 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 17267839.07 | 931.50 | 14-JAN-17:03 | 8.90 | 4.06 | 0.302400E+09 | 406.81 | 27-JAN-10:30 | -25.0 | -25.4 |
February | 0.255203E+09 | 1383.14 | 26-FEB-14:01 | 15.78 | 5.88 | 0.280337E+09 | 461.95 | 27-FEB-14:00 | 18.90 | 7.23 |
March | 0.650253E+09 | 1271.88 | 29-MAR-16:00 | 12.20 | 4.07 | 0.342410E+09 | 473.26 | 29-MAR-13:00 | 12.20 | 4.07 |
April | 0.118575E+10 | 1497.54 | 07-APR-14:50 | 21.97 | 9.03 | 0.324652E+09 | 537.64 | 07-APR-13:00 | 21.97 | 9.03 |
May | 0.193913E+10 | 3410.62 | 30-MAY-15:30 | 19.40 | 10.94 | 0.385028E+09 | 549.49 | 30-MAY-09:09 | 19.40 | 10.94 |
June | 0.350792E+10 | 4772.79 | 29-JUN-15:30 | 31.65 | 14.51 | 0.429118E+09 | 549.50 | 23-JUN-09:09 | 31.65 | 14.51 |
July | 0.456172E+10 | 8618.25 | 16-JUL-18:21 | 32.50 | 17.04 | 0.403896E+09 | 549.50 | 13-JUL-09:00 | 32.50 | 17.04 |
August | 0.406599E+10 | 5638.62 | 09-AUG-14:50 | 33.40 | 16.01 | 0.450641E+09 | 549.50 | 01-AUG-13:09 | 33.40 | 16.01 |
September | 0.277199E+10 | 8258.04 | 04-SEP-16:11 | 32.80 | 16.58 | 0.384908E+09 | 549.50 | 07-SEP-09:00 | 16.70 | 15.61 |
October | 0.177230E+10 | 2551.60 | 19-OCT-14:30 | 21.40 | 10.24 | 0.371828E+09 | 549.48 | 19-OCT-13:00 | 21.40 | 10.24 |
November | 0.926240E+09 | 1374.15 | 08-NOV-14:00 | 13.90 | 7.97 | 0.325157E+09 | 506.76 | 08-NOV-14:09 | 13.78 | 7.92 |
December | 0.211411E+09 | 1106.26 | 06-DEC-16:00 | 9.40 | 4.51 | 0.296438E+09 | 435.99 | 06-DEC-14:00 | 9.40 | 4.51 |
Annual Sum or Average | 0.218652E+11 | 0.429681E+10 | ||||||||
Minimum of Months | 17267839.07 | 931.50 | 8.90 | 4.06 | 0.280337E+09 | 406.81 | -25.0 | -25.4 | ||
Maximum of Months | 0.456172E+10 | 8618.25 | 33.40 | 17.04 | 0.450641E+09 | 549.50 | 33.40 | 17.04 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 98156707.58 | 1023.75 | 20-JAN-10:05 | -3.1 | -5.8 | 0.193454E+09 | 274.68 | 20-JAN-10:09 | -3.1 | -5.8 |
February | 0.481822E+09 | 1681.82 | 27-FEB-10:30 | 13.05 | 4.83 | 0.184667E+09 | 347.88 | 28-FEB-10:09 | 1.57 | -0.3 |
March | 0.995176E+09 | 2574.42 | 28-MAR-08:40 | 4.07 | -0.3 | 0.232840E+09 | 347.87 | 22-MAR-09:20 | 4.07 | -0.3 |
April | 0.162376E+10 | 4347.55 | 25-APR-09:30 | 10.80 | 5.26 | 0.224561E+09 | 347.87 | 24-APR-09:30 | 10.80 | 5.26 |
May | 0.244171E+10 | 5435.04 | 19-MAY-09:20 | 18.53 | 11.74 | 0.258299E+09 | 347.89 | 02-MAY-13:09 | 18.53 | 11.74 |
June | 0.456623E+10 | 11001.99 | 25-JUN-08:41 | 16.52 | 11.73 | 0.273516E+09 | 348.35 | 23-JUN-09:00 | 16.52 | 11.73 |
July | 0.592903E+10 | 13361.62 | 16-JUL-09:01 | 22.38 | 16.15 | 0.256896E+09 | 348.21 | 13-JUL-09:39 | 22.38 | 16.15 |
August | 0.543832E+10 | 12632.84 | 06-AUG-09:21 | 28.60 | 14.63 | 0.286870E+09 | 348.34 | 11-AUG-09:00 | 27.80 | 12.62 |
September | 0.331367E+10 | 12594.87 | 04-SEP-08:51 | 26.70 | 14.88 | 0.249025E+09 | 347.88 | 14-SEP-13:00 | 21.70 | 13.42 |
October | 0.200317E+10 | 4172.93 | 18-OCT-09:40 | 19.07 | 8.41 | 0.247270E+09 | 347.88 | 16-OCT-09:09 | 19.07 | 8.41 |
November | 0.100789E+10 | 2064.32 | 03-NOV-09:15 | 7.10 | 4.34 | 0.213700E+09 | 347.87 | 03-NOV-09:09 | 7.10 | 4.34 |
December | 0.315997E+09 | 1108.81 | 06-DEC-10:40 | 9.07 | 5.19 | 0.188987E+09 | 288.25 | 07-DEC-10:00 | 6.10 | 2.52 |
Annual Sum or Average | 0.282149E+11 | 0.281009E+10 | ||||||||
Minimum of Months | 98156707.58 | 1023.75 | -3.1 | -5.8 | 0.184667E+09 | 274.68 | -3.1 | -5.8 | ||
Maximum of Months | 0.592903E+10 | 13361.62 | 28.60 | 16.15 | 0.286870E+09 | 348.35 | 27.80 | 16.15 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.346224E+09 | 2702.70 | 14-JAN-12:30 | 10.30 | 4.97 | 0.285473E+09 | 537.49 | 02-JAN-14:09 | 10.30 | 4.97 |
February | 0.112225E+10 | 15374.55 | 26-FEB-14:01 | 15.78 | 5.88 | 0.289305E+09 | 549.60 | 27-FEB-14:20 | 18.50 | 7.10 |
March | 0.142287E+10 | 8121.59 | 01-MAR-13:20 | 5.97 | 2.26 | 0.359323E+09 | 549.50 | 16-MAR-13:09 | 5.10 | -1.2 |
April | 0.170670E+10 | 6742.46 | 25-APR-12:07 | 15.28 | 6.55 | 0.334910E+09 | 549.50 | 13-APR-13:09 | 15.28 | 6.55 |
May | 0.251834E+10 | 7864.82 | 19-MAY-14:00 | 27.20 | 15.02 | 0.376683E+09 | 549.52 | 02-MAY-13:09 | 27.20 | 15.02 |
June | 0.471151E+10 | 11228.10 | 29-JUN-12:00 | 30.60 | 14.31 | 0.415506E+09 | 549.52 | 19-JUN-13:39 | 30.60 | 14.31 |
July | 0.717606E+10 | 15848.68 | 16-JUL-12:22 | 28.60 | 17.88 | 0.400865E+09 | 597.11 | 17-JUL-12:09 | 35.18 | 16.48 |
August | 0.782772E+10 | 15978.44 | 06-AUG-13:21 | 34.15 | 15.08 | 0.445943E+09 | 596.84 | 07-AUG-12:09 | 32.80 | 15.88 |
September | 0.592011E+10 | 17078.35 | 04-SEP-14:51 | 32.20 | 16.66 | 0.383325E+09 | 560.68 | 07-SEP-15:09 | 24.78 | 20.11 |
October | 0.408447E+10 | 16717.50 | 15-OCT-15:02 | 22.70 | 11.00 | 0.385267E+09 | 551.06 | 18-OCT-13:00 | 25.00 | 11.40 |
November | 0.195929E+10 | 10135.84 | 03-NOV-12:07 | 12.62 | 7.22 | 0.349061E+09 | 549.50 | 13-NOV-14:00 | 4.30 | -1.8 |
December | 0.682443E+09 | 3878.24 | 02-DEC-13:30 | 9.40 | 4.37 | 0.301518E+09 | 549.50 | 12-DEC-14:00 | -2.8 | -5.6 |
Annual Sum or Average | 0.394780E+11 | 0.432718E+10 | ||||||||
Minimum of Months | 0.346224E+09 | 2702.70 | 5.97 | 2.26 | 0.285473E+09 | 537.49 | -2.8 | -5.6 | ||
Maximum of Months | 0.782772E+10 | 17078.35 | 34.15 | 17.88 | 0.445943E+09 | 597.11 | 35.18 | 20.11 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.101323E+09 | 1282.85 | 13-JAN-16:00 | 8.90 | 4.67 | 0.193782E+09 | 293.41 | 13-JAN-15:00 | 8.90 | 4.67 |
February | 0.480248E+09 | 3492.70 | 28-FEB-16:50 | 10.18 | 4.40 | 0.182081E+09 | 338.70 | 27-FEB-16:49 | 10.18 | 4.40 |
March | 0.945178E+09 | 3743.63 | 28-MAR-17:30 | 9.75 | 2.59 | 0.222201E+09 | 347.77 | 02-MAR-14:00 | 9.75 | 2.59 |
April | 0.157569E+10 | 5897.29 | 25-APR-17:30 | 17.50 | 7.72 | 0.210168E+09 | 347.84 | 07-APR-13:00 | 17.50 | 7.72 |
May | 0.256519E+10 | 13594.98 | 28-MAY-18:52 | 18.90 | 10.17 | 0.246619E+09 | 347.84 | 30-MAY-13:00 | 18.90 | 10.34 |
June | 0.406034E+10 | 11426.43 | 24-JUN-17:42 | 26.38 | 11.78 | 0.269890E+09 | 347.85 | 29-JUN-09:20 | 25.17 | 12.64 |
July | 0.516490E+10 | 15124.15 | 16-JUL-18:21 | 32.50 | 17.04 | 0.255803E+09 | 347.86 | 13-JUL-09:00 | 32.50 | 17.04 |
August | 0.476566E+10 | 13593.63 | 06-AUG-16:41 | 35.10 | 15.80 | 0.284257E+09 | 347.85 | 01-AUG-13:09 | 35.10 | 15.80 |
September | 0.327330E+10 | 14794.60 | 04-SEP-16:51 | 32.80 | 16.77 | 0.242714E+09 | 347.86 | 07-SEP-09:00 | 16.70 | 15.61 |
October | 0.208536E+10 | 6689.88 | 15-OCT-16:22 | 21.65 | 10.63 | 0.235761E+09 | 347.84 | 19-OCT-13:00 | 21.10 | 10.22 |
November | 0.107135E+10 | 3060.45 | 03-NOV-15:50 | 14.35 | 7.69 | 0.210513E+09 | 346.75 | 09-NOV-14:00 | 9.00 | 3.82 |
December | 0.313970E+09 | 1477.25 | 06-DEC-15:50 | 9.68 | 4.65 | 0.190141E+09 | 324.96 | 06-DEC-15:00 | 9.40 | 4.51 |
Annual Sum or Average | 0.264025E+11 | 0.274393E+10 | ||||||||
Minimum of Months | 0.101323E+09 | 1282.85 | 8.90 | 2.59 | 0.182081E+09 | 293.41 | 8.90 | 2.59 | ||
Maximum of Months | 0.516490E+10 | 15124.15 | 35.10 | 17.04 | 0.284257E+09 | 347.86 | 35.10 | 17.04 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 69069407.88 | 1021.31 | 13-JAN-16:40 | 8.17 | 4.18 | 0.304143E+09 | 410.94 | 13-JAN-14:00 | 8.17 | 4.18 |
February | 0.438654E+09 | 1589.43 | 27-FEB-13:30 | 17.75 | 6.76 | 0.285512E+09 | 513.00 | 27-FEB-14:00 | 18.90 | 7.23 |
March | 0.111010E+10 | 1535.39 | 23-MAR-13:30 | 9.70 | 2.18 | 0.361527E+09 | 534.35 | 29-MAR-13:00 | 12.80 | 4.50 |
April | 0.171458E+10 | 3592.07 | 07-APR-14:30 | 22.50 | 9.29 | 0.355373E+09 | 549.48 | 13-APR-13:00 | 13.30 | 7.60 |
May | 0.263277E+10 | 4952.69 | 19-MAY-16:00 | 27.80 | 14.54 | 0.405259E+09 | 549.50 | 04-MAY-13:09 | 27.80 | 14.54 |
June | 0.468569E+10 | 8177.03 | 30-JUN-06:02 | 12.67 | 9.41 | 0.432490E+09 | 549.50 | 29-JUN-09:20 | 12.67 | 9.41 |
July | 0.549492E+10 | 10512.99 | 16-JUL-18:21 | 32.50 | 17.04 | 0.404849E+09 | 549.98 | 18-JUL-13:20 | 33.17 | 17.33 |
August | 0.484265E+10 | 9450.11 | 06-AUG-15:51 | 35.60 | 16.36 | 0.451996E+09 | 549.50 | 01-AUG-13:09 | 35.60 | 16.36 |
September | 0.298872E+10 | 10325.43 | 04-SEP-16:11 | 32.80 | 16.58 | 0.386462E+09 | 549.51 | 07-SEP-09:00 | 16.70 | 15.61 |
October | 0.177905E+10 | 3159.51 | 19-OCT-14:30 | 21.40 | 10.24 | 0.372499E+09 | 549.48 | 19-OCT-13:00 | 21.40 | 10.24 |
November | 0.916175E+09 | 1570.97 | 03-NOV-13:30 | 14.35 | 7.74 | 0.326773E+09 | 520.08 | 08-NOV-14:20 | 13.67 | 7.87 |
December | 0.254823E+09 | 1152.37 | 06-DEC-16:20 | 8.50 | 3.80 | 0.297200E+09 | 449.02 | 06-DEC-14:00 | 8.50 | 3.80 |
Annual Sum or Average | 0.269272E+11 | 0.438408E+10 | ||||||||
Minimum of Months | 69069407.88 | 1021.31 | 8.17 | 2.18 | 0.285512E+09 | 410.94 | 8.17 | 3.80 | ||
Maximum of Months | 0.549492E+10 | 10512.99 | 35.60 | 17.04 | 0.451996E+09 | 549.98 | 35.60 | 17.33 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.173105E+09 | 1324.76 | 20-JAN-10:00 | -3.3 | -5.9 | 0.142598E+09 | 276.00 | 20-JAN-09:00 | -3.3 | -5.9 |
February | 0.668444E+09 | 3054.11 | 28-FEB-09:55 | 1.10 | -0.5 | 0.136676E+09 | 338.72 | 28-FEB-11:09 | 4.37 | 1.41 |
March | 0.146810E+10 | 4889.82 | 23-MAR-10:10 | 8.40 | 1.62 | 0.173353E+09 | 338.72 | 22-MAR-10:09 | 8.40 | 1.62 |
April | 0.243606E+10 | 8504.22 | 16-APR-09:53 | 15.00 | 6.35 | 0.167824E+09 | 338.72 | 13-APR-14:09 | 15.00 | 6.35 |
May | 0.332845E+10 | 8380.99 | 19-MAY-08:40 | 17.23 | 11.19 | 0.191378E+09 | 338.75 | 02-MAY-12:09 | 17.23 | 11.19 |
June | 0.540595E+10 | 13532.68 | 25-JUN-08:32 | 16.33 | 11.66 | 0.201534E+09 | 339.01 | 21-JUN-08:00 | 16.33 | 11.66 |
July | 0.647196E+10 | 17102.24 | 02-JUL-09:01 | 22.48 | 15.33 | 0.189823E+09 | 344.20 | 17-JUL-07:19 | 23.53 | 15.09 |
August | 0.584881E+10 | 15506.10 | 06-AUG-08:32 | 25.90 | 14.14 | 0.210610E+09 | 340.19 | 07-AUG-10:30 | 30.60 | 15.17 |
September | 0.358590E+10 | 15750.73 | 04-SEP-08:51 | 26.70 | 14.88 | 0.180095E+09 | 339.76 | 07-SEP-15:09 | 24.78 | 20.11 |
October | 0.214922E+10 | 5488.02 | 18-OCT-09:00 | 17.20 | 7.57 | 0.175469E+09 | 338.72 | 19-OCT-10:09 | 19.18 | 9.33 |
November | 0.104636E+10 | 2768.09 | 03-NOV-10:10 | 9.10 | 5.57 | 0.153296E+09 | 338.72 | 03-NOV-10:09 | 9.10 | 5.57 |
December | 0.331350E+09 | 1377.13 | 20-DEC-10:00 | 3.30 | -0.6 | 0.138662E+09 | 283.12 | 20-DEC-09:00 | 3.30 | -0.6 |
Annual Sum or Average | 0.329137E+11 | 0.206132E+10 | ||||||||
Minimum of Months | 0.173105E+09 | 1324.76 | -3.3 | -5.9 | 0.136676E+09 | 276.00 | -3.3 | -5.9 | ||
Maximum of Months | 0.647196E+10 | 17102.24 | 26.70 | 15.33 | 0.210610E+09 | 344.20 | 30.60 | 20.11 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.115059E+10 | 7012.99 | 19-JAN-13:30 | -6.2 | -7.9 | 0.332437E+09 | 549.49 | 31-JAN-14:00 | -1.1 | -4.4 |
February | 0.245329E+10 | 17920.67 | 26-FEB-13:32 | 15.40 | 5.68 | 0.327600E+09 | 549.80 | 28-FEB-14:00 | 10.60 | 4.78 |
March | 0.358017E+10 | 12716.14 | 01-MAR-13:40 | 6.33 | 2.52 | 0.395191E+09 | 549.59 | 01-MAR-14:00 | 8.30 | 3.44 |
April | 0.386635E+10 | 16539.93 | 16-APR-14:52 | 19.40 | 8.41 | 0.363832E+09 | 549.88 | 24-APR-13:00 | 17.80 | 9.82 |
May | 0.461048E+10 | 10482.04 | 19-MAY-13:30 | 26.65 | 14.96 | 0.407755E+09 | 549.53 | 02-MAY-13:09 | 26.65 | 14.96 |
June | 0.648073E+10 | 13843.00 | 25-JUN-13:53 | 24.40 | 13.66 | 0.429260E+09 | 549.53 | 19-JUN-13:39 | 24.40 | 13.66 |
July | 0.799879E+10 | 18753.13 | 16-JUL-12:22 | 28.60 | 17.88 | 0.404023E+09 | 550.15 | 18-JUL-13:50 | 32.07 | 17.42 |
August | 0.878964E+10 | 18356.50 | 06-AUG-13:12 | 34.07 | 14.98 | 0.450763E+09 | 550.25 | 22-AUG-13:50 | 24.13 | 15.51 |
September | 0.709186E+10 | 19595.26 | 04-SEP-14:51 | 32.20 | 16.66 | 0.390705E+09 | 562.48 | 07-SEP-15:09 | 24.78 | 20.11 |
October | 0.546852E+10 | 18672.91 | 15-OCT-13:32 | 22.93 | 11.00 | 0.395298E+09 | 558.36 | 18-OCT-13:30 | 24.70 | 11.11 |
November | 0.318184E+10 | 12727.80 | 03-NOV-13:10 | 13.92 | 7.65 | 0.367366E+09 | 549.57 | 03-NOV-13:00 | 15.00 | 7.85 |
December | 0.160754E+10 | 7495.17 | 12-DEC-12:30 | -2.8 | -5.7 | 0.333331E+09 | 549.49 | 07-DEC-10:00 | -2.8 | -5.7 |
Annual Sum or Average | 0.562798E+11 | 0.459756E+10 | ||||||||
Minimum of Months | 0.115059E+10 | 7012.99 | -6.2 | -7.9 | 0.327600E+09 | 549.49 | -2.8 | -5.7 | ||
Maximum of Months | 0.878964E+10 | 19595.26 | 34.07 | 17.88 | 0.450763E+09 | 562.48 | 32.07 | 20.11 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.191178E+09 | 1640.29 | 13-JAN-15:50 | 9.08 | 4.76 | 0.194707E+09 | 311.99 | 13-JAN-15:00 | 8.90 | 4.67 |
February | 0.711812E+09 | 4799.93 | 28-FEB-16:40 | 10.37 | 4.49 | 0.184450E+09 | 347.82 | 27-FEB-14:00 | 10.37 | 4.49 |
March | 0.147291E+10 | 5834.47 | 28-MAR-16:00 | 10.60 | 3.09 | 0.227547E+09 | 347.84 | 02-MAR-14:30 | 10.60 | 3.09 |
April | 0.238634E+10 | 15889.00 | 16-APR-17:32 | 19.60 | 8.82 | 0.216674E+09 | 347.84 | 07-APR-13:00 | 19.60 | 8.82 |
May | 0.349210E+10 | 15632.05 | 28-MAY-17:02 | 20.92 | 10.40 | 0.248778E+09 | 347.85 | 25-MAY-13:09 | 20.92 | 10.40 |
June | 0.500381E+10 | 16595.21 | 18-JUN-17:51 | 25.00 | 14.46 | 0.268943E+09 | 347.86 | 19-JUN-13:39 | 24.80 | 12.00 |
July | 0.583311E+10 | 18089.20 | 16-JUL-17:01 | 33.22 | 17.33 | 0.254470E+09 | 347.86 | 13-JUL-09:00 | 33.22 | 17.33 |
August | 0.531280E+10 | 15934.51 | 06-AUG-16:31 | 35.20 | 15.91 | 0.281891E+09 | 347.85 | 01-AUG-13:09 | 35.20 | 15.91 |
September | 0.362917E+10 | 17632.15 | 04-SEP-16:11 | 32.80 | 16.58 | 0.236969E+09 | 347.86 | 07-SEP-09:00 | 16.70 | 15.61 |
October | 0.227813E+10 | 11035.33 | 15-OCT-16:12 | 21.83 | 10.69 | 0.228567E+09 | 347.84 | 19-OCT-13:00 | 21.10 | 10.22 |
November | 0.113335E+10 | 3793.26 | 03-NOV-15:40 | 14.40 | 7.69 | 0.208770E+09 | 347.83 | 09-NOV-14:00 | 9.00 | 3.82 |
December | 0.377859E+09 | 1808.30 | 06-DEC-15:50 | 9.68 | 4.65 | 0.190668E+09 | 335.78 | 06-DEC-15:00 | 9.40 | 4.51 |
Annual Sum or Average | 0.318226E+11 | 0.274243E+10 | ||||||||
Minimum of Months | 0.191178E+09 | 1640.29 | 9.08 | 3.09 | 0.184450E+09 | 311.99 | 8.90 | 3.09 | ||
Maximum of Months | 0.583311E+10 | 18089.20 | 35.20 | 17.33 | 0.281891E+09 | 347.86 | 35.20 | 17.33 |
Report: ZoneHeatingSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 10990726.20 | 6761.03 | 09-JAN-06:02 | -27.2 |
February | 1666161.10 | 5800.44 | 06-FEB-07:01 | 0.50 |
March | 0.00 | 0.00 | 01-MAR-00:10 | -3.0 |
April | 0.00 | 0.00 | 01-APR-00:10 | 2.68 |
May | 0.00 | 0.00 | 01-MAY-00:10 | -1.1 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 18.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 11.57 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 4.98 |
December | 0.00 | 0.00 | 01-DEC-00:10 | -2.1 |
Annual Sum or Average | 12656887.30 | |||
Minimum of Months | 0.00 | 0.00 | -27.2 | |
Maximum of Months | 10990726.20 | 6761.03 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.910656E+10 | 19258.61 | 11-JAN-06:09 | -32.1 |
February | 0.464451E+10 | 16281.54 | 04-FEB-06:07 | -19.5 |
March | 0.327572E+10 | 16385.86 | 06-MAR-05:11 | -17.8 |
April | 0.131605E+10 | 9010.19 | 29-APR-06:03 | -6.8 |
May | 0.898437E+09 | 9734.57 | 08-MAY-06:02 | -2.7 |
June | 0.291569E+09 | 4400.03 | 25-JUN-06:17 | 12.03 |
July | 0.151354E+09 | 4385.39 | 02-JUL-07:12 | 18.33 |
August | 0.250324E+09 | 4468.90 | 06-AUG-07:32 | 22.57 |
September | 0.575611E+09 | 4611.80 | 24-SEP-08:22 | 13.35 |
October | 0.130391E+10 | 11222.16 | 10-OCT-06:03 | -6.1 |
November | 0.326625E+10 | 15319.96 | 27-NOV-06:07 | -14.5 |
December | 0.672931E+10 | 18105.52 | 29-DEC-06:08 | -25.1 |
Annual Sum or Average | 0.318096E+11 | |||
Minimum of Months | 0.151354E+09 | 4385.39 | -32.1 | |
Maximum of Months | 0.910656E+10 | 19258.61 | 22.57 |
Report: ZoneHeatingSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.364803E+10 | 10203.41 | 09-JAN-08:23 | -26.9 |
February | 0.200894E+10 | 9046.99 | 06-FEB-07:12 | 0.40 |
March | 0.143096E+10 | 8372.67 | 06-MAR-07:09 | -19.7 |
April | 0.470679E+09 | 8341.81 | 16-APR-15:32 | 19.80 |
May | 0.439594E+09 | 3572.95 | 28-MAY-17:02 | 20.92 |
June | 24593009.25 | 4478.11 | 18-JUN-14:32 | 24.03 |
July | 35900431.46 | 4873.45 | 16-JUL-15:41 | 32.88 |
August | 23617206.77 | 4943.71 | 06-AUG-15:51 | 35.60 |
September | 0.155571E+09 | 5786.14 | 24-SEP-10:32 | 19.83 |
October | 0.548065E+09 | 7570.79 | 15-OCT-16:12 | 21.83 |
November | 0.147052E+10 | 7914.94 | 27-NOV-07:06 | -13.5 |
December | 0.245663E+10 | 8842.67 | 26-DEC-07:17 | -8.7 |
Annual Sum or Average | 0.127131E+11 | |||
Minimum of Months | 23617206.77 | 3572.95 | -26.9 | |
Maximum of Months | 0.364803E+10 | 10203.41 | 35.60 |
Report: ZoneHeatingSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.249349E+10 | 5702.29 | 09-JAN-07:01 | -27.2 |
February | 0.129502E+10 | 5272.18 | 06-FEB-07:01 | 0.50 |
March | 0.774681E+09 | 4403.36 | 06-MAR-09:10 | -9.5 |
April | 0.159635E+09 | 3198.90 | 25-APR-05:03 | 1.10 |
May | 0.174783E+09 | 5670.76 | 22-MAY-05:03 | -0.6 |
June | 20146322.64 | 2266.20 | 18-JUN-13:13 | 22.57 |
July | 28778566.99 | 3160.77 | 16-JUL-15:41 | 32.88 |
August | 24252158.20 | 3446.22 | 06-AUG-15:21 | 35.00 |
September | 41649578.23 | 2891.96 | 24-SEP-11:13 | 21.33 |
October | 0.154088E+09 | 5028.64 | 04-OCT-05:02 | -0.5 |
November | 0.753310E+09 | 6358.80 | 06-NOV-06:01 | -3.5 |
December | 0.166353E+10 | 4198.31 | 26-DEC-08:30 | -10.0 |
Annual Sum or Average | 0.758336E+10 | |||
Minimum of Months | 20146322.64 | 2266.20 | -27.2 | |
Maximum of Months | 0.249349E+10 | 6358.80 | 35.00 |
Report: ZoneHeatingSummaryMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.920781E+09 | 17872.36 | 09-JAN-05:11 | -27.2 |
February | 0.210395E+09 | 16873.62 | 06-FEB-05:01 | -0.4 |
March | 0.100621E+09 | 15982.41 | 06-MAR-06:02 | -16.3 |
April | 0.00 | 0.00 | 01-APR-00:10 | 2.68 |
May | 1758553.72 | 12644.81 | 01-MAY-06:01 | 0.10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 18.43 |
October | 752770.03 | 12546.17 | 10-OCT-06:01 | -6.1 |
November | 69622648.24 | 15074.45 | 27-NOV-06:01 | -14.5 |
December | 0.295590E+09 | 16091.41 | 26-DEC-06:01 | -7.9 |
Annual Sum or Average | 0.159952E+10 | |||
Minimum of Months | 0.00 | 0.00 | -27.2 | |
Maximum of Months | 0.920781E+09 | 17872.36 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.435562E+10 | 26772.37 | 30-JAN-04:52 | -17.2 |
February | 0.154622E+10 | 26249.20 | 06-FEB-05:01 | -0.4 |
March | 0.737230E+09 | 26271.83 | 06-MAR-05:01 | -18.4 |
April | 40358061.18 | 20695.75 | 29-APR-05:01 | -7.7 |
May | 0.103397E+09 | 22040.28 | 01-MAY-05:01 | -0.5 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
September | 365369.22 | 2387.06 | 19-SEP-06:03 | 2.20 |
October | 71203414.66 | 22268.27 | 10-OCT-05:01 | -6.1 |
November | 0.791504E+09 | 25792.03 | 27-NOV-05:01 | -15.4 |
December | 0.240694E+10 | 26839.22 | 31-DEC-22:12 | -23.9 |
Annual Sum or Average | 0.100528E+11 | |||
Minimum of Months | 0.00 | 0.00 | -23.9 | |
Maximum of Months | 0.435562E+10 | 26839.22 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.716627E+10 | 10733.80 | 30-JAN-04:52 | -17.2 |
February | 0.343075E+10 | 10316.03 | 05-FEB-07:42 | -20.0 |
March | 0.184253E+10 | 10427.26 | 06-MAR-03:02 | -18.8 |
April | 0.315908E+09 | 8615.69 | 29-APR-05:01 | -7.7 |
May | 0.206441E+09 | 9278.89 | 08-MAY-04:02 | -2.3 |
June | 620630.43 | 3654.43 | 17-JUN-06:03 | 6.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
August | 420843.00 | 2805.62 | 18-AUG-06:03 | 8.17 |
September | 36595713.88 | 7999.22 | 19-SEP-05:12 | 2.20 |
October | 0.323030E+09 | 9310.15 | 10-OCT-04:02 | -5.2 |
November | 0.188830E+10 | 10364.14 | 27-NOV-04:22 | -15.7 |
December | 0.490805E+10 | 10722.07 | 31-DEC-22:12 | -23.9 |
Annual Sum or Average | 0.201189E+11 | |||
Minimum of Months | 0.00 | 0.00 | -23.9 | |
Maximum of Months | 0.716627E+10 | 10733.80 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.424275E+10 | 9864.80 | 30-JAN-04:52 | -17.2 |
February | 0.188386E+10 | 9375.85 | 05-FEB-07:42 | -20.0 |
March | 0.100416E+10 | 9469.36 | 06-MAR-03:02 | -18.8 |
April | 0.144567E+09 | 7434.36 | 28-APR-05:01 | -6.5 |
May | 0.107840E+09 | 8155.66 | 08-MAY-04:02 | -2.3 |
June | 420127.79 | 2072.65 | 16-JUN-06:03 | 2.70 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
September | 20842849.78 | 6697.43 | 19-SEP-05:12 | 2.20 |
October | 0.168429E+09 | 8199.96 | 10-OCT-04:02 | -5.2 |
November | 0.106768E+10 | 9405.77 | 27-NOV-04:22 | -15.7 |
December | 0.285842E+10 | 9851.52 | 31-DEC-22:12 | -23.9 |
Annual Sum or Average | 0.114990E+11 | |||
Minimum of Months | 0.00 | 0.00 | -23.9 | |
Maximum of Months | 0.424275E+10 | 9864.80 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.509766E+10 | 13832.21 | 08-JAN-06:32 | -27.0 |
February | 0.216975E+10 | 13343.62 | 05-FEB-07:42 | -20.0 |
March | 0.134381E+10 | 13412.88 | 06-MAR-03:02 | -18.8 |
April | 0.283774E+09 | 10734.19 | 29-APR-05:01 | -7.7 |
May | 0.230423E+09 | 11680.90 | 08-MAY-04:02 | -2.3 |
June | 2994534.07 | 7699.18 | 17-JUN-06:03 | 6.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
August | 1503804.36 | 7213.11 | 18-AUG-06:03 | 8.17 |
September | 31782938.23 | 9722.41 | 19-SEP-05:12 | 2.20 |
October | 0.205881E+09 | 11697.40 | 10-OCT-04:02 | -5.2 |
November | 0.121808E+10 | 13331.26 | 27-NOV-04:22 | -15.7 |
December | 0.330285E+10 | 13900.66 | 31-DEC-08:12 | -27.4 |
Annual Sum or Average | 0.138885E+11 | |||
Minimum of Months | 0.00 | 0.00 | -27.4 | |
Maximum of Months | 0.509766E+10 | 13900.66 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.452747E+10 | 10514.65 | 30-JAN-04:52 | -17.2 |
February | 0.202437E+10 | 9957.55 | 05-FEB-07:42 | -20.0 |
March | 0.115150E+10 | 10092.28 | 06-MAR-03:02 | -18.8 |
April | 0.204055E+09 | 7783.28 | 28-APR-05:01 | -6.5 |
May | 0.146724E+09 | 8637.13 | 08-MAY-04:02 | -2.3 |
June | 2442440.21 | 4954.82 | 17-JUN-06:03 | 6.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
August | 1211023.11 | 4669.54 | 18-AUG-06:03 | 8.17 |
September | 27655836.45 | 7041.57 | 19-SEP-05:12 | 2.20 |
October | 0.201454E+09 | 8690.62 | 10-OCT-04:02 | -5.2 |
November | 0.114066E+10 | 10027.06 | 27-NOV-04:22 | -15.7 |
December | 0.304552E+10 | 10502.38 | 31-DEC-22:12 | -23.9 |
Annual Sum or Average | 0.124731E+11 | |||
Minimum of Months | 0.00 | 0.00 | -23.9 | |
Maximum of Months | 0.452747E+10 | 10514.65 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.470465E+10 | 8012.35 | 29-JAN-22:12 | -26.8 |
February | 0.229809E+10 | 7672.16 | 06-FEB-05:01 | -0.4 |
March | 0.105599E+10 | 7736.41 | 06-MAR-03:02 | -18.8 |
April | 0.128286E+09 | 6532.98 | 29-APR-05:01 | -7.7 |
May | 56790383.84 | 6595.66 | 01-MAY-05:01 | -0.5 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
September | 448470.37 | 1664.17 | 20-SEP-06:03 | 3.48 |
October | 17592614.68 | 6066.92 | 10-OCT-06:01 | -6.1 |
November | 0.546342E+09 | 7388.61 | 27-NOV-05:01 | -15.4 |
December | 0.232425E+10 | 7956.90 | 31-DEC-22:12 | -23.9 |
Annual Sum or Average | 0.111324E+11 | |||
Minimum of Months | 0.00 | 0.00 | -26.8 | |
Maximum of Months | 0.470465E+10 | 8012.35 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.265550E+10 | 7417.13 | 08-JAN-18:32 | -27.2 |
February | 0.115181E+10 | 6992.07 | 06-FEB-05:01 | -0.4 |
March | 0.441723E+09 | 7142.92 | 06-MAR-05:01 | -18.4 |
April | 42863207.64 | 5636.86 | 29-APR-05:01 | -7.7 |
May | 20905892.79 | 5642.00 | 01-MAY-05:01 | -0.5 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
September | 46033.40 | 306.89 | 20-SEP-06:03 | 3.48 |
October | 8362379.32 | 5077.48 | 10-OCT-06:01 | -6.1 |
November | 0.295617E+09 | 6677.66 | 27-NOV-05:01 | -15.4 |
December | 0.129072E+10 | 7371.70 | 31-DEC-22:12 | -23.9 |
Annual Sum or Average | 0.590755E+10 | |||
Minimum of Months | 0.00 | 0.00 | -27.2 | |
Maximum of Months | 0.265550E+10 | 7417.13 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.651099E+10 | 14558.43 | 11-JAN-07:10 | -27.2 |
February | 0.345700E+10 | 13811.38 | 01-FEB-07:10 | -24.9 |
March | 0.246452E+10 | 12994.23 | 06-MAR-07:10 | -19.7 |
April | 0.131038E+10 | 10298.12 | 28-APR-06:10 | -5.2 |
May | 0.112383E+10 | 9822.75 | 08-MAY-06:10 | -2.7 |
June | 0.218247E+09 | 8011.92 | 16-JUN-07:00 | 2.20 |
July | 17049981.21 | 5904.13 | 05-JUL-06:06 | 9.40 |
August | 0.126321E+09 | 7295.44 | 18-AUG-06:03 | 8.17 |
September | 0.394895E+09 | 8067.41 | 19-SEP-07:00 | 2.20 |
October | 0.675723E+09 | 9866.37 | 10-OCT-06:10 | -6.1 |
November | 0.182432E+10 | 11614.36 | 27-NOV-07:10 | -13.5 |
December | 0.401295E+10 | 14166.31 | 29-DEC-07:10 | -26.0 |
Annual Sum or Average | 0.221362E+11 | |||
Minimum of Months | 17049981.21 | 5904.13 | -27.2 | |
Maximum of Months | 0.651099E+10 | 14558.43 | 9.40 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.287983E+10 | 7741.97 | 08-JAN-18:32 | -27.2 |
February | 0.119891E+10 | 7351.71 | 06-FEB-05:01 | -0.4 |
March | 0.527393E+09 | 7486.57 | 06-MAR-05:01 | -18.4 |
April | 59412400.20 | 5700.50 | 29-APR-05:01 | -7.7 |
May | 26987769.42 | 5745.24 | 08-MAY-05:01 | -2.8 |
June | 2178.15 | 14.52 | 17-JUN-06:03 | 6.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
September | 97322.84 | 475.37 | 19-SEP-06:03 | 2.20 |
October | 9964203.97 | 5244.95 | 10-OCT-06:01 | -6.1 |
November | 0.291964E+09 | 6996.17 | 27-NOV-05:01 | -15.4 |
December | 0.137068E+10 | 7739.71 | 31-DEC-22:12 | -23.9 |
Annual Sum or Average | 0.636524E+10 | |||
Minimum of Months | 0.00 | 0.00 | -27.2 | |
Maximum of Months | 0.287983E+10 | 7741.97 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.432291E+10 | 8623.36 | 08-JAN-18:32 | -27.2 |
February | 0.178125E+10 | 8144.49 | 06-FEB-05:01 | -0.4 |
March | 0.663613E+09 | 8257.68 | 06-MAR-05:11 | -17.8 |
April | 42809925.31 | 6798.77 | 29-APR-05:01 | -7.7 |
May | 40090700.79 | 6968.04 | 08-MAY-05:01 | -2.8 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
September | 1684802.35 | 4744.68 | 19-SEP-06:03 | 2.20 |
October | 48334122.11 | 6969.77 | 10-OCT-05:01 | -6.1 |
November | 0.682126E+09 | 8201.97 | 27-NOV-05:01 | -15.4 |
December | 0.239773E+10 | 8397.24 | 31-DEC-23:21 | -23.6 |
Annual Sum or Average | 0.998055E+10 | |||
Minimum of Months | 0.00 | 0.00 | -27.2 | |
Maximum of Months | 0.432291E+10 | 8623.36 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.257534E+10 | 8351.62 | 08-JAN-18:32 | -27.2 |
February | 0.984755E+09 | 7717.60 | 06-FEB-05:01 | -0.4 |
March | 0.361193E+09 | 7874.46 | 06-MAR-05:11 | -17.8 |
April | 22907725.65 | 5985.51 | 29-APR-05:01 | -7.7 |
May | 23239786.39 | 6159.66 | 08-MAY-05:01 | -2.8 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
September | 2469259.44 | 4555.51 | 19-SEP-06:03 | 2.20 |
October | 29713388.32 | 6173.56 | 10-OCT-05:01 | -6.1 |
November | 0.425700E+09 | 7815.27 | 27-NOV-05:01 | -15.4 |
December | 0.143073E+10 | 8045.77 | 31-DEC-23:21 | -23.6 |
Annual Sum or Average | 0.585605E+10 | |||
Minimum of Months | 0.00 | 0.00 | -27.2 | |
Maximum of Months | 0.257534E+10 | 8351.62 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.283136E+10 | 11186.81 | 09-JAN-05:11 | -27.2 |
February | 0.966892E+09 | 10488.88 | 06-FEB-05:01 | -0.4 |
March | 0.415783E+09 | 10709.90 | 06-MAR-05:11 | -17.8 |
April | 43970261.85 | 8350.97 | 29-APR-05:01 | -7.7 |
May | 50151171.24 | 8585.20 | 08-MAY-05:01 | -2.8 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.42 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
September | 2174770.32 | 5500.20 | 19-SEP-06:03 | 2.20 |
October | 32531455.41 | 8576.56 | 10-OCT-05:01 | -6.1 |
November | 0.429372E+09 | 10587.89 | 27-NOV-05:01 | -15.4 |
December | 0.148560E+10 | 10943.83 | 31-DEC-23:21 | -23.6 |
Annual Sum or Average | 0.625783E+10 | |||
Minimum of Months | 0.00 | 0.00 | -27.2 | |
Maximum of Months | 0.283136E+10 | 11186.81 | 19.45 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.270369E+10 | 8560.61 | 08-JAN-18:32 | -27.2 |
February | 0.102453E+10 | 7937.50 | 06-FEB-05:01 | -0.4 |
March | 0.418664E+09 | 8106.90 | 06-MAR-05:11 | -17.8 |
April | 36223163.02 | 5976.16 | 29-APR-05:01 | -7.7 |
May | 31623104.67 | 6310.04 | 08-MAY-05:01 | -2.8 |
June | 191290.01 | 1275.27 | 17-JUN-06:03 | 6.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19.45 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.90 |
September | 2634584.71 | 4589.96 | 19-SEP-06:03 | 2.20 |
October | 34918371.55 | 6329.24 | 10-OCT-05:01 | -6.1 |
November | 0.422000E+09 | 8045.55 | 27-NOV-05:01 | -15.4 |
December | 0.148916E+10 | 8286.43 | 31-DEC-23:21 | -23.6 |
Annual Sum or Average | 0.616363E+10 | |||
Minimum of Months | 0.00 | 0.00 | -27.2 | |
Maximum of Months | 0.270369E+10 | 8560.61 | 19.45 |
Report: ZoneElectricSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.599791E+10 | 6443.98 | 02-JAN-08:09 | 0.210964E+11 | 14019.75 | 02-JAN-08:09 |
February | 0.544142E+10 | 6443.98 | 01-FEB-08:09 | 0.191215E+11 | 14019.75 | 01-FEB-08:09 |
March | 0.648083E+10 | 6443.98 | 01-MAR-08:09 | 0.217104E+11 | 14019.75 | 01-MAR-08:09 |
April | 0.577357E+10 | 6443.98 | 03-APR-07:10 | 0.204846E+11 | 14019.75 | 03-APR-07:10 |
May | 0.623937E+10 | 6443.98 | 01-MAY-07:10 | 0.214034E+11 | 14019.75 | 01-MAY-07:10 |
June | 0.621476E+10 | 6443.98 | 01-JUN-07:10 | 0.209475E+11 | 14019.75 | 01-JUN-07:10 |
July | 0.579818E+10 | 6443.98 | 03-JUL-07:10 | 0.209382E+11 | 14019.75 | 03-JUL-07:10 |
August | 0.648074E+10 | 6443.98 | 01-AUG-07:10 | 0.217104E+11 | 14019.75 | 01-AUG-07:10 |
September | 0.577357E+10 | 6443.98 | 01-SEP-07:10 | 0.204802E+11 | 14019.75 | 01-SEP-07:10 |
October | 0.599800E+10 | 6443.98 | 02-OCT-07:10 | 0.210986E+11 | 14019.75 | 02-OCT-07:10 |
November | 0.593174E+10 | 6443.98 | 01-NOV-07:10 | 0.204961E+11 | 14019.75 | 01-NOV-07:10 |
December | 0.579827E+10 | 6443.98 | 01-DEC-08:09 | 0.209360E+11 | 14019.75 | 01-DEC-08:09 |
Annual Sum or Average | 0.719283E+11 | 0.250423E+12 | ||||
Minimum of Months | 0.544142E+10 | 6443.98 | 0.191215E+11 | 14019.75 | ||
Maximum of Months | 0.648083E+10 | 6443.98 | 0.217104E+11 | 14019.75 |
Report: ZoneElectricSummaryMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.599791E+10 | 6443.98 | 02-JAN-08:09 | 0.971303E+10 | 6808.32 | 02-JAN-08:09 |
February | 0.544142E+10 | 6443.98 | 01-FEB-08:09 | 0.879311E+10 | 6808.32 | 01-FEB-08:09 |
March | 0.648083E+10 | 6443.98 | 01-MAR-08:09 | 0.101015E+11 | 6808.32 | 01-MAR-08:09 |
April | 0.577357E+10 | 6443.98 | 03-APR-07:10 | 0.937947E+10 | 6808.32 | 03-APR-07:10 |
May | 0.623937E+10 | 6443.98 | 01-MAY-07:10 | 0.990724E+10 | 6808.32 | 01-MAY-07:10 |
June | 0.621476E+10 | 6443.98 | 01-JUN-07:10 | 0.972788E+10 | 6808.32 | 01-JUN-07:10 |
July | 0.579818E+10 | 6443.98 | 03-JUL-07:10 | 0.955663E+10 | 6808.32 | 03-JUL-07:10 |
August | 0.648074E+10 | 6443.98 | 01-AUG-07:10 | 0.101015E+11 | 6808.32 | 01-AUG-07:10 |
September | 0.577357E+10 | 6443.98 | 01-SEP-07:10 | 0.937507E+10 | 6808.32 | 01-SEP-07:10 |
October | 0.599800E+10 | 6443.98 | 02-OCT-07:10 | 0.971523E+10 | 6808.32 | 02-OCT-07:10 |
November | 0.593174E+10 | 6443.98 | 01-NOV-07:10 | 0.950025E+10 | 6808.32 | 01-NOV-07:10 |
December | 0.579827E+10 | 6443.98 | 01-DEC-08:09 | 0.955443E+10 | 6808.32 | 01-DEC-08:09 |
Annual Sum or Average | 0.719283E+11 | 0.115425E+12 | ||||
Minimum of Months | 0.544142E+10 | 6443.98 | 0.879311E+10 | 6808.32 | ||
Maximum of Months | 0.648083E+10 | 6443.98 | 0.101015E+11 | 6808.32 |
Report: ZoneElectricSummaryMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.599791E+10 | 6443.98 | 02-JAN-08:09 | 0.971303E+10 | 6808.32 | 02-JAN-08:09 |
February | 0.544142E+10 | 6443.98 | 01-FEB-08:09 | 0.879311E+10 | 6808.32 | 01-FEB-08:09 |
March | 0.648083E+10 | 6443.98 | 01-MAR-08:09 | 0.101015E+11 | 6808.32 | 01-MAR-08:09 |
April | 0.577357E+10 | 6443.98 | 03-APR-07:10 | 0.937947E+10 | 6808.32 | 03-APR-07:10 |
May | 0.623937E+10 | 6443.98 | 01-MAY-07:10 | 0.990724E+10 | 6808.32 | 01-MAY-07:10 |
June | 0.621476E+10 | 6443.98 | 01-JUN-07:10 | 0.972788E+10 | 6808.32 | 01-JUN-07:10 |
July | 0.579818E+10 | 6443.98 | 03-JUL-07:10 | 0.955663E+10 | 6808.32 | 03-JUL-07:10 |
August | 0.648074E+10 | 6443.98 | 01-AUG-07:10 | 0.101015E+11 | 6808.32 | 01-AUG-07:10 |
September | 0.577357E+10 | 6443.98 | 01-SEP-07:10 | 0.937507E+10 | 6808.32 | 01-SEP-07:10 |
October | 0.599800E+10 | 6443.98 | 02-OCT-07:10 | 0.971523E+10 | 6808.32 | 02-OCT-07:10 |
November | 0.593174E+10 | 6443.98 | 01-NOV-07:10 | 0.950025E+10 | 6808.32 | 01-NOV-07:10 |
December | 0.579827E+10 | 6443.98 | 01-DEC-08:09 | 0.955443E+10 | 6808.32 | 01-DEC-08:09 |
Annual Sum or Average | 0.719283E+11 | 0.115425E+12 | ||||
Minimum of Months | 0.544142E+10 | 6443.98 | 0.879311E+10 | 6808.32 | ||
Maximum of Months | 0.648083E+10 | 6443.98 | 0.101015E+11 | 6808.32 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.891502E+09 | 1358.45 | 02-JAN-08:09 | 0.204758E+10 | 1435.25 | 02-JAN-08:09 |
February | 0.710238E+09 | 1358.45 | 01-FEB-08:09 | 0.185366E+10 | 1435.25 | 01-FEB-08:09 |
March | 0.783810E+09 | 1358.45 | 17-MAR-07:10 | 0.212947E+10 | 1435.25 | 01-MAR-08:09 |
April | 0.662339E+09 | 1184.79 | 14-APR-07:10 | 0.197726E+10 | 1435.25 | 03-APR-07:10 |
May | 0.687673E+09 | 947.97 | 03-MAY-07:10 | 0.208852E+10 | 1435.25 | 01-MAY-07:10 |
June | 0.669543E+09 | 711.15 | 16-JUN-07:10 | 0.205071E+10 | 1435.25 | 01-JUN-07:10 |
July | 0.636928E+09 | 774.31 | 07-JUL-07:19 | 0.201461E+10 | 1435.25 | 03-JUL-07:10 |
August | 0.717147E+09 | 774.31 | 17-AUG-07:10 | 0.212947E+10 | 1435.25 | 01-AUG-07:10 |
September | 0.680368E+09 | 1184.79 | 11-SEP-07:10 | 0.197634E+10 | 1435.25 | 01-SEP-07:10 |
October | 0.761506E+09 | 1358.45 | 25-OCT-07:10 | 0.204804E+10 | 1435.25 | 02-OCT-07:10 |
November | 0.837212E+09 | 1358.45 | 01-NOV-07:10 | 0.200273E+10 | 1435.25 | 01-NOV-07:10 |
December | 0.871754E+09 | 1358.45 | 01-DEC-08:09 | 0.201415E+10 | 1435.25 | 01-DEC-08:09 |
Annual Sum or Average | 0.891002E+10 | 0.243325E+11 | ||||
Minimum of Months | 0.636928E+09 | 711.15 | 0.185366E+10 | 1435.25 | ||
Maximum of Months | 0.891502E+09 | 1358.45 | 0.212947E+10 | 1435.25 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.541101E+09 | 860.01 | 02-JAN-08:09 | 0.129621E+10 | 908.57 | 02-JAN-08:09 |
February | 0.438776E+09 | 750.07 | 01-FEB-16:00 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.489006E+09 | 860.01 | 17-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.416629E+09 | 600.14 | 14-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.436811E+09 | 490.21 | 03-MAY-07:10 | 0.132213E+10 | 908.57 | 01-MAY-07:10 |
June | 0.428518E+09 | 410.22 | 01-JUN-07:10 | 0.129819E+10 | 908.57 | 01-JUN-07:10 |
July | 0.404649E+09 | 450.21 | 03-JUL-15:20 | 0.127534E+10 | 908.57 | 03-JUL-07:10 |
August | 0.456541E+09 | 490.21 | 17-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.427159E+09 | 600.14 | 13-SEP-07:10 | 0.125111E+10 | 908.57 | 01-SEP-07:10 |
October | 0.467940E+09 | 860.01 | 25-OCT-07:10 | 0.129650E+10 | 908.57 | 02-OCT-07:10 |
November | 0.511979E+09 | 860.01 | 01-NOV-07:10 | 0.126781E+10 | 908.57 | 01-NOV-07:10 |
December | 0.528006E+09 | 860.01 | 01-DEC-08:09 | 0.127504E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.554712E+10 | 0.154036E+11 | ||||
Minimum of Months | 0.404649E+09 | 410.22 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.541101E+09 | 860.01 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.832446E+09 | 1358.45 | 02-JAN-08:09 | 0.204757E+10 | 1435.24 | 02-JAN-08:09 |
February | 0.675230E+09 | 1121.62 | 02-FEB-08:09 | 0.185364E+10 | 1435.24 | 01-FEB-08:09 |
March | 0.770859E+09 | 1358.45 | 17-MAR-07:10 | 0.212945E+10 | 1435.24 | 01-MAR-08:09 |
April | 0.662781E+09 | 1184.79 | 14-APR-07:10 | 0.197725E+10 | 1435.24 | 03-APR-07:10 |
May | 0.692191E+09 | 947.97 | 03-MAY-07:10 | 0.208851E+10 | 1435.24 | 01-MAY-07:10 |
June | 0.676582E+09 | 711.15 | 01-JUN-07:10 | 0.205070E+10 | 1435.24 | 01-JUN-07:10 |
July | 0.641472E+09 | 774.31 | 07-JUL-07:19 | 0.201460E+10 | 1435.24 | 03-JUL-07:10 |
August | 0.723314E+09 | 774.31 | 17-AUG-07:10 | 0.212945E+10 | 1435.24 | 01-AUG-07:10 |
September | 0.675673E+09 | 1184.79 | 11-SEP-07:10 | 0.197632E+10 | 1435.24 | 01-SEP-07:10 |
October | 0.729461E+09 | 1358.45 | 25-OCT-07:10 | 0.204803E+10 | 1435.24 | 02-OCT-07:10 |
November | 0.780932E+09 | 1358.45 | 01-NOV-07:10 | 0.200271E+10 | 1435.24 | 01-NOV-07:10 |
December | 0.804817E+09 | 1358.45 | 01-DEC-08:09 | 0.201413E+10 | 1435.24 | 01-DEC-08:09 |
Annual Sum or Average | 0.866576E+10 | 0.243324E+11 | ||||
Minimum of Months | 0.641472E+09 | 711.15 | 0.185364E+10 | 1435.24 | ||
Maximum of Months | 0.832446E+09 | 1358.45 | 0.212945E+10 | 1435.24 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.547834E+09 | 859.95 | 02-JAN-08:09 | 0.129620E+10 | 908.57 | 02-JAN-08:09 |
February | 0.438492E+09 | 859.95 | 01-FEB-08:09 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.493866E+09 | 859.95 | 17-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.421217E+09 | 750.02 | 14-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.436887E+09 | 600.10 | 03-MAY-07:10 | 0.132212E+10 | 908.57 | 01-MAY-07:10 |
June | 0.424533E+09 | 450.19 | 01-JUN-07:10 | 0.129818E+10 | 908.57 | 01-JUN-07:10 |
July | 0.404856E+09 | 490.17 | 07-JUL-07:10 | 0.127533E+10 | 908.57 | 03-JUL-07:10 |
August | 0.456578E+09 | 600.10 | 17-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.430933E+09 | 750.02 | 11-SEP-07:10 | 0.125110E+10 | 908.57 | 01-SEP-07:10 |
October | 0.475964E+09 | 859.95 | 25-OCT-07:10 | 0.129649E+10 | 908.57 | 02-OCT-07:10 |
November | 0.509622E+09 | 859.95 | 01-NOV-07:10 | 0.126780E+10 | 908.57 | 01-NOV-07:10 |
December | 0.527360E+09 | 859.95 | 01-DEC-08:09 | 0.127503E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.556814E+10 | 0.154035E+11 | ||||
Minimum of Months | 0.404856E+09 | 450.19 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.547834E+09 | 859.95 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.885990E+09 | 1358.45 | 02-JAN-08:09 | 0.204758E+10 | 1435.25 | 02-JAN-08:09 |
February | 0.706861E+09 | 1184.79 | 01-FEB-08:09 | 0.185366E+10 | 1435.25 | 01-FEB-08:09 |
March | 0.781245E+09 | 1358.45 | 17-MAR-07:10 | 0.212947E+10 | 1435.25 | 01-MAR-08:09 |
April | 0.661011E+09 | 1011.14 | 14-APR-07:10 | 0.197726E+10 | 1435.25 | 03-APR-07:10 |
May | 0.687223E+09 | 947.97 | 03-MAY-07:10 | 0.208852E+10 | 1435.25 | 01-MAY-07:10 |
June | 0.668995E+09 | 711.15 | 16-JUN-07:10 | 0.205071E+10 | 1435.25 | 01-JUN-07:10 |
July | 0.636466E+09 | 774.31 | 07-JUL-07:30 | 0.201461E+10 | 1435.25 | 03-JUL-07:10 |
August | 0.716620E+09 | 774.31 | 17-AUG-07:10 | 0.212947E+10 | 1435.25 | 01-AUG-07:10 |
September | 0.678980E+09 | 1184.79 | 11-SEP-07:10 | 0.197634E+10 | 1435.25 | 01-SEP-07:10 |
October | 0.757811E+09 | 1358.45 | 25-OCT-07:10 | 0.204804E+10 | 1435.25 | 02-OCT-07:10 |
November | 0.832267E+09 | 1358.45 | 01-NOV-07:10 | 0.200273E+10 | 1435.25 | 01-NOV-07:10 |
December | 0.865635E+09 | 1358.45 | 01-DEC-08:09 | 0.201415E+10 | 1435.25 | 01-DEC-08:09 |
Annual Sum or Average | 0.887910E+10 | 0.243325E+11 | ||||
Minimum of Months | 0.636466E+09 | 711.15 | 0.185366E+10 | 1435.25 | ||
Maximum of Months | 0.885990E+09 | 1358.45 | 0.212947E+10 | 1435.25 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.538435E+09 | 860.01 | 02-JAN-08:09 | 0.129621E+10 | 908.57 | 02-JAN-08:09 |
February | 0.437398E+09 | 750.07 | 01-FEB-16:00 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.488194E+09 | 860.01 | 17-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.415976E+09 | 600.14 | 14-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.436359E+09 | 490.21 | 03-MAY-07:10 | 0.132213E+10 | 908.57 | 01-MAY-07:10 |
June | 0.427956E+09 | 410.22 | 01-JUN-07:10 | 0.129819E+10 | 908.57 | 01-JUN-07:10 |
July | 0.404257E+09 | 450.21 | 07-JUL-07:19 | 0.127534E+10 | 908.57 | 03-JUL-07:10 |
August | 0.455980E+09 | 450.21 | 17-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.426285E+09 | 600.14 | 13-SEP-07:10 | 0.125111E+10 | 908.57 | 01-SEP-07:10 |
October | 0.466954E+09 | 860.01 | 25-OCT-07:10 | 0.129650E+10 | 908.57 | 02-OCT-07:10 |
November | 0.510543E+09 | 860.01 | 01-NOV-07:10 | 0.126781E+10 | 908.57 | 01-NOV-07:10 |
December | 0.525328E+09 | 860.01 | 01-DEC-08:09 | 0.127504E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.553367E+10 | 0.154036E+11 | ||||
Minimum of Months | 0.404257E+09 | 410.22 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.538435E+09 | 860.01 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.830922E+09 | 1358.45 | 02-JAN-08:09 | 0.204757E+10 | 1435.24 | 02-JAN-08:09 |
February | 0.674141E+09 | 1121.62 | 02-FEB-08:09 | 0.185364E+10 | 1435.24 | 01-FEB-08:09 |
March | 0.769330E+09 | 1358.45 | 17-MAR-07:10 | 0.212945E+10 | 1435.24 | 01-MAR-08:09 |
April | 0.661230E+09 | 1011.14 | 14-APR-07:10 | 0.197725E+10 | 1435.24 | 03-APR-07:10 |
May | 0.691353E+09 | 947.97 | 03-MAY-07:10 | 0.208851E+10 | 1435.24 | 01-MAY-07:10 |
June | 0.675688E+09 | 711.15 | 16-JUN-07:10 | 0.205070E+10 | 1435.24 | 01-JUN-07:10 |
July | 0.640699E+09 | 774.31 | 07-JUL-07:30 | 0.201460E+10 | 1435.24 | 03-JUL-07:10 |
August | 0.722265E+09 | 774.31 | 17-AUG-07:10 | 0.212945E+10 | 1435.24 | 01-AUG-07:10 |
September | 0.674425E+09 | 947.97 | 11-SEP-07:10 | 0.197632E+10 | 1435.24 | 01-SEP-07:10 |
October | 0.728076E+09 | 1358.45 | 25-OCT-07:10 | 0.204803E+10 | 1435.24 | 02-OCT-07:10 |
November | 0.778960E+09 | 1358.45 | 01-NOV-07:10 | 0.200271E+10 | 1435.24 | 01-NOV-07:10 |
December | 0.801365E+09 | 1358.45 | 01-DEC-08:09 | 0.201413E+10 | 1435.24 | 01-DEC-08:09 |
Annual Sum or Average | 0.864845E+10 | 0.243324E+11 | ||||
Minimum of Months | 0.640699E+09 | 711.15 | 0.185364E+10 | 1435.24 | ||
Maximum of Months | 0.830922E+09 | 1358.45 | 0.212945E+10 | 1435.24 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.545876E+09 | 859.95 | 02-JAN-08:09 | 0.129620E+10 | 908.57 | 02-JAN-08:09 |
February | 0.437388E+09 | 859.95 | 02-FEB-08:09 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.492404E+09 | 859.95 | 17-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.420379E+09 | 750.02 | 14-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.436264E+09 | 600.10 | 03-MAY-07:10 | 0.132212E+10 | 908.57 | 01-MAY-07:10 |
June | 0.424135E+09 | 450.19 | 01-JUN-07:10 | 0.129818E+10 | 908.57 | 01-JUN-07:10 |
July | 0.404466E+09 | 490.17 | 07-JUL-07:10 | 0.127533E+10 | 908.57 | 03-JUL-07:10 |
August | 0.455908E+09 | 600.10 | 17-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.429910E+09 | 750.02 | 11-SEP-07:10 | 0.125110E+10 | 908.57 | 01-SEP-07:10 |
October | 0.473985E+09 | 859.95 | 25-OCT-07:10 | 0.129649E+10 | 908.57 | 02-OCT-07:10 |
November | 0.507544E+09 | 859.95 | 01-NOV-07:10 | 0.126780E+10 | 908.57 | 01-NOV-07:10 |
December | 0.525651E+09 | 859.95 | 01-DEC-08:09 | 0.127503E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.555391E+10 | 0.154035E+11 | ||||
Minimum of Months | 0.404466E+09 | 450.19 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.545876E+09 | 859.95 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.891464E+09 | 1358.45 | 02-JAN-08:09 | 0.204758E+10 | 1435.25 | 02-JAN-08:09 |
February | 0.710238E+09 | 1358.45 | 01-FEB-08:09 | 0.185366E+10 | 1435.25 | 01-FEB-08:09 |
March | 0.783810E+09 | 1358.45 | 17-MAR-07:10 | 0.212947E+10 | 1435.25 | 01-MAR-08:09 |
April | 0.662339E+09 | 1184.79 | 14-APR-07:10 | 0.197726E+10 | 1435.25 | 03-APR-07:10 |
May | 0.687673E+09 | 947.97 | 03-MAY-07:10 | 0.208852E+10 | 1435.25 | 01-MAY-07:10 |
June | 0.669543E+09 | 711.15 | 16-JUN-07:10 | 0.205071E+10 | 1435.25 | 01-JUN-07:10 |
July | 0.636928E+09 | 774.31 | 07-JUL-07:19 | 0.201461E+10 | 1435.25 | 03-JUL-07:10 |
August | 0.717147E+09 | 774.31 | 17-AUG-07:10 | 0.212947E+10 | 1435.25 | 01-AUG-07:10 |
September | 0.680368E+09 | 1184.79 | 11-SEP-07:10 | 0.197634E+10 | 1435.25 | 01-SEP-07:10 |
October | 0.761506E+09 | 1358.45 | 25-OCT-07:10 | 0.204804E+10 | 1435.25 | 02-OCT-07:10 |
November | 0.837212E+09 | 1358.45 | 01-NOV-07:10 | 0.200273E+10 | 1435.25 | 01-NOV-07:10 |
December | 0.871754E+09 | 1358.45 | 01-DEC-08:09 | 0.201415E+10 | 1435.25 | 01-DEC-08:09 |
Annual Sum or Average | 0.890998E+10 | 0.243325E+11 | ||||
Minimum of Months | 0.636928E+09 | 711.15 | 0.185366E+10 | 1435.25 | ||
Maximum of Months | 0.891464E+09 | 1358.45 | 0.212947E+10 | 1435.25 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.541101E+09 | 860.01 | 02-JAN-08:09 | 0.129621E+10 | 908.57 | 02-JAN-08:09 |
February | 0.438776E+09 | 750.07 | 01-FEB-16:00 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.489006E+09 | 860.01 | 17-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.416629E+09 | 600.14 | 14-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.436811E+09 | 490.21 | 03-MAY-07:10 | 0.132213E+10 | 908.57 | 01-MAY-07:10 |
June | 0.428518E+09 | 410.22 | 01-JUN-07:10 | 0.129819E+10 | 908.57 | 01-JUN-07:10 |
July | 0.404635E+09 | 450.21 | 03-JUL-15:20 | 0.127534E+10 | 908.57 | 03-JUL-07:10 |
August | 0.456541E+09 | 490.21 | 17-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.427159E+09 | 600.14 | 13-SEP-07:10 | 0.125111E+10 | 908.57 | 01-SEP-07:10 |
October | 0.467940E+09 | 860.01 | 25-OCT-07:10 | 0.129650E+10 | 908.57 | 02-OCT-07:10 |
November | 0.511979E+09 | 860.01 | 01-NOV-07:10 | 0.126781E+10 | 908.57 | 01-NOV-07:10 |
December | 0.528006E+09 | 860.01 | 01-DEC-08:09 | 0.127504E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.554710E+10 | 0.154036E+11 | ||||
Minimum of Months | 0.404635E+09 | 410.22 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.541101E+09 | 860.01 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.832446E+09 | 1358.45 | 02-JAN-08:09 | 0.204757E+10 | 1435.24 | 02-JAN-08:09 |
February | 0.675230E+09 | 1121.62 | 02-FEB-08:09 | 0.185364E+10 | 1435.24 | 01-FEB-08:09 |
March | 0.770859E+09 | 1358.45 | 17-MAR-07:10 | 0.212945E+10 | 1435.24 | 01-MAR-08:09 |
April | 0.662781E+09 | 1184.79 | 14-APR-07:10 | 0.197725E+10 | 1435.24 | 03-APR-07:10 |
May | 0.692191E+09 | 947.97 | 03-MAY-07:10 | 0.208851E+10 | 1435.24 | 01-MAY-07:10 |
June | 0.676582E+09 | 711.15 | 01-JUN-07:10 | 0.205070E+10 | 1435.24 | 01-JUN-07:10 |
July | 0.641434E+09 | 774.31 | 07-JUL-07:19 | 0.201460E+10 | 1435.24 | 03-JUL-07:10 |
August | 0.723314E+09 | 774.31 | 17-AUG-07:10 | 0.212945E+10 | 1435.24 | 01-AUG-07:10 |
September | 0.675673E+09 | 1184.79 | 11-SEP-07:10 | 0.197632E+10 | 1435.24 | 01-SEP-07:10 |
October | 0.729461E+09 | 1358.45 | 25-OCT-07:10 | 0.204803E+10 | 1435.24 | 02-OCT-07:10 |
November | 0.780932E+09 | 1358.45 | 01-NOV-07:10 | 0.200271E+10 | 1435.24 | 01-NOV-07:10 |
December | 0.804817E+09 | 1358.45 | 01-DEC-08:09 | 0.201413E+10 | 1435.24 | 01-DEC-08:09 |
Annual Sum or Average | 0.866572E+10 | 0.243324E+11 | ||||
Minimum of Months | 0.641434E+09 | 711.15 | 0.185364E+10 | 1435.24 | ||
Maximum of Months | 0.832446E+09 | 1358.45 | 0.212945E+10 | 1435.24 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.547834E+09 | 859.95 | 02-JAN-08:09 | 0.129620E+10 | 908.57 | 02-JAN-08:09 |
February | 0.438492E+09 | 859.95 | 01-FEB-08:09 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.493866E+09 | 859.95 | 17-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.421217E+09 | 750.02 | 14-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.436887E+09 | 600.10 | 03-MAY-07:10 | 0.132212E+10 | 908.57 | 01-MAY-07:10 |
June | 0.424533E+09 | 450.19 | 01-JUN-07:10 | 0.129818E+10 | 908.57 | 01-JUN-07:10 |
July | 0.404856E+09 | 490.17 | 07-JUL-07:10 | 0.127533E+10 | 908.57 | 03-JUL-07:10 |
August | 0.456578E+09 | 600.10 | 17-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.430933E+09 | 750.02 | 11-SEP-07:10 | 0.125110E+10 | 908.57 | 01-SEP-07:10 |
October | 0.475940E+09 | 859.95 | 25-OCT-07:10 | 0.129649E+10 | 908.57 | 02-OCT-07:10 |
November | 0.509622E+09 | 859.95 | 01-NOV-07:10 | 0.126780E+10 | 908.57 | 01-NOV-07:10 |
December | 0.527360E+09 | 859.95 | 01-DEC-08:09 | 0.127503E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.556812E+10 | 0.154035E+11 | ||||
Minimum of Months | 0.404856E+09 | 450.19 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.547834E+09 | 859.95 | 0.134804E+10 | 908.57 |
Report: SpaceGainsMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.599791E+10 | 0.210964E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.544142E+10 | 0.191215E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.648083E+10 | 0.217104E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.577357E+10 | 0.204846E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.623937E+10 | 0.214034E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.621476E+10 | 0.209475E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.579818E+10 | 0.209382E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.648074E+10 | 0.217104E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.577357E+10 | 0.204802E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.599800E+10 | 0.210986E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.593174E+10 | 0.204961E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.579827E+10 | 0.209360E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.719283E+11 | 0.250423E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.544142E+10 | 0.191215E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.648083E+10 | 0.217104E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.599791E+10 | 0.971303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.544142E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.648083E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.577357E+10 | 0.937947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.623937E+10 | 0.990724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.621476E+10 | 0.972788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.579818E+10 | 0.955663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.648074E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.577357E+10 | 0.937507E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.599800E+10 | 0.971523E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.593174E+10 | 0.950025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.579827E+10 | 0.955443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.719283E+11 | 0.115425E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.544142E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.648083E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.599791E+10 | 0.971303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.544142E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.648083E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.577357E+10 | 0.937947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.623937E+10 | 0.990724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.621476E+10 | 0.972788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.579818E+10 | 0.955663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.648074E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.577357E+10 | 0.937507E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.599800E+10 | 0.971523E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.593174E+10 | 0.950025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.579827E+10 | 0.955443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.719283E+11 | 0.115425E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.544142E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.648083E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.891502E+09 | 0.204758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.789241E+09 |
February | 0.901968E+09 | 0.710238E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.605178E+09 |
March | 0.107774E+10 | 0.783810E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.561484E+09 |
April | 0.956342E+09 | 0.662339E+09 | 0.197726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.403218E+09 |
May | 0.103597E+10 | 0.687673E+09 | 0.208852E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1014395.35 | 0.416157E+09 |
June | 0.103308E+10 | 0.669543E+09 | 0.205071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5261575.20 | 0.216726E+09 |
July | 0.959235E+09 | 0.636928E+09 | 0.201461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18189073.55 | 0.146739E+09 |
August | 0.107774E+10 | 0.717147E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15378526.37 | 0.157887E+09 |
September | 0.956342E+09 | 0.680368E+09 | 0.197634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9675762.13 | 0.274546E+09 |
October | 0.994195E+09 | 0.761506E+09 | 0.204804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 291054.26 | 0.381031E+09 |
November | 0.984487E+09 | 0.837212E+09 | 0.200273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.538017E+09 |
December | 0.959235E+09 | 0.871754E+09 | 0.201415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.690093E+09 |
Annual Sum or Average | 0.119305E+11 | 0.891002E+10 | 0.243325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 49810386.86 | 0.518032E+10 |
Minimum of Months | 0.901968E+09 | 0.636928E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146739E+09 |
Maximum of Months | 0.107774E+10 | 0.891502E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18189073.55 | 0.789241E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629407E+09 | 0.541101E+09 | 0.129621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.529793E+09 |
February | 0.571020E+09 | 0.438776E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.412167E+09 |
March | 0.682301E+09 | 0.489006E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.381381E+09 |
April | 0.605444E+09 | 0.416629E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.276673E+09 |
May | 0.655854E+09 | 0.436811E+09 | 0.132213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 707143.29 | 0.277592E+09 |
June | 0.654023E+09 | 0.428518E+09 | 0.129819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3562660.63 | 0.146051E+09 |
July | 0.607275E+09 | 0.404649E+09 | 0.127534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11824702.10 | 0.100227E+09 |
August | 0.682301E+09 | 0.456541E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10197071.28 | 0.106640E+09 |
September | 0.605444E+09 | 0.427159E+09 | 0.125111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6239551.62 | 0.187160E+09 |
October | 0.629407E+09 | 0.467940E+09 | 0.129650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50182.15 | 0.262041E+09 |
November | 0.623262E+09 | 0.511979E+09 | 0.126781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.361754E+09 |
December | 0.607275E+09 | 0.528006E+09 | 0.127504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.463219E+09 |
Annual Sum or Average | 0.755301E+10 | 0.554712E+10 | 0.154036E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 32581311.06 | 0.350470E+10 |
Minimum of Months | 0.571020E+09 | 0.404649E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100227E+09 |
Maximum of Months | 0.682301E+09 | 0.541101E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11824702.10 | 0.529793E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.832446E+09 | 0.204757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.818326E+09 |
February | 0.901968E+09 | 0.675230E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.654619E+09 |
March | 0.107774E+10 | 0.770859E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.592229E+09 |
April | 0.956342E+09 | 0.662781E+09 | 0.197725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.424368E+09 |
May | 0.103597E+10 | 0.692191E+09 | 0.208851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1018012.51 | 0.422269E+09 |
June | 0.103308E+10 | 0.676582E+09 | 0.205070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5244439.11 | 0.216723E+09 |
July | 0.959235E+09 | 0.641472E+09 | 0.201460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17302932.25 | 0.147992E+09 |
August | 0.107774E+10 | 0.723314E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15056777.38 | 0.161617E+09 |
September | 0.956342E+09 | 0.675673E+09 | 0.197632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8540206.08 | 0.287465E+09 |
October | 0.994195E+09 | 0.729461E+09 | 0.204803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57690.53 | 0.418448E+09 |
November | 0.984487E+09 | 0.780932E+09 | 0.200271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.571383E+09 |
December | 0.959235E+09 | 0.804817E+09 | 0.201413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.726116E+09 |
Annual Sum or Average | 0.119305E+11 | 0.866576E+10 | 0.243324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 47220057.85 | 0.544155E+10 |
Minimum of Months | 0.901968E+09 | 0.641472E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147992E+09 |
Maximum of Months | 0.107774E+10 | 0.832446E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17302932.25 | 0.818326E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.547834E+09 | 0.129620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.528459E+09 |
February | 0.570983E+09 | 0.438492E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.411997E+09 |
March | 0.682256E+09 | 0.493866E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.381644E+09 |
April | 0.605404E+09 | 0.421217E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.278020E+09 |
May | 0.655811E+09 | 0.436887E+09 | 0.132212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 670332.32 | 0.284560E+09 |
June | 0.653980E+09 | 0.424533E+09 | 0.129818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3477699.02 | 0.146796E+09 |
July | 0.607235E+09 | 0.404856E+09 | 0.127533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12066240.42 | 0.101467E+09 |
August | 0.682256E+09 | 0.456578E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10273572.22 | 0.106775E+09 |
September | 0.605404E+09 | 0.430933E+09 | 0.125110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6597996.36 | 0.185678E+09 |
October | 0.629366E+09 | 0.475964E+09 | 0.129649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 87425.51 | 0.259829E+09 |
November | 0.623221E+09 | 0.509622E+09 | 0.126780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.363096E+09 |
December | 0.607235E+09 | 0.527360E+09 | 0.127503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.463462E+09 |
Annual Sum or Average | 0.755252E+10 | 0.556814E+10 | 0.154035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 33173265.84 | 0.351178E+10 |
Minimum of Months | 0.570983E+09 | 0.404856E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101467E+09 |
Maximum of Months | 0.682256E+09 | 0.547834E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12066240.42 | 0.528459E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.885990E+09 | 0.204758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.436075E+09 |
February | 0.901968E+09 | 0.706861E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.336442E+09 |
March | 0.107774E+10 | 0.781245E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.305922E+09 |
April | 0.956342E+09 | 0.661011E+09 | 0.197726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.214532E+09 |
May | 0.103597E+10 | 0.687223E+09 | 0.208852E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 616431.48 | 0.222689E+09 |
June | 0.103308E+10 | 0.668995E+09 | 0.205071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3016079.00 | 0.114618E+09 |
July | 0.959235E+09 | 0.636466E+09 | 0.201461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10765363.33 | 77547101.10 |
August | 0.107774E+10 | 0.716620E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8688387.29 | 85470741.51 |
September | 0.956342E+09 | 0.678980E+09 | 0.197634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5760859.86 | 0.154756E+09 |
October | 0.994195E+09 | 0.757811E+09 | 0.204804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 83271.23 | 0.224181E+09 |
November | 0.984487E+09 | 0.832267E+09 | 0.200273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.311671E+09 |
December | 0.959235E+09 | 0.865635E+09 | 0.201415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.392249E+09 |
Annual Sum or Average | 0.119305E+11 | 0.887910E+10 | 0.243325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 28930392.18 | 0.287615E+10 |
Minimum of Months | 0.901968E+09 | 0.636466E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77547101.10 |
Maximum of Months | 0.107774E+10 | 0.885990E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10765363.33 | 0.436075E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629407E+09 | 0.538435E+09 | 0.129621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.293648E+09 |
February | 0.571020E+09 | 0.437398E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.230961E+09 |
March | 0.682301E+09 | 0.488194E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.210179E+09 |
April | 0.605444E+09 | 0.415976E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151709E+09 |
May | 0.655854E+09 | 0.436359E+09 | 0.132213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 385922.20 | 0.153835E+09 |
June | 0.654023E+09 | 0.427956E+09 | 0.129819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1933213.09 | 80688922.52 |
July | 0.607275E+09 | 0.404257E+09 | 0.127534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6408431.21 | 56222393.44 |
August | 0.682301E+09 | 0.455980E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5482606.03 | 60361902.07 |
September | 0.605444E+09 | 0.426285E+09 | 0.125111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3335414.39 | 0.108368E+09 |
October | 0.629407E+09 | 0.466954E+09 | 0.129650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22194.10 | 0.156961E+09 |
November | 0.623262E+09 | 0.510543E+09 | 0.126781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.211736E+09 |
December | 0.607275E+09 | 0.525328E+09 | 0.127504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.264421E+09 |
Annual Sum or Average | 0.755301E+10 | 0.553367E+10 | 0.154036E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 17567781.03 | 0.197909E+10 |
Minimum of Months | 0.571020E+09 | 0.404257E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56222393.44 |
Maximum of Months | 0.682301E+09 | 0.538435E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6408431.21 | 0.293648E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.830922E+09 | 0.204757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.706622E+10 |
February | 0.901968E+09 | 0.674141E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.528609E+10 |
March | 0.107774E+10 | 0.769330E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.510796E+10 |
April | 0.956342E+09 | 0.661230E+09 | 0.197725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.326517E+10 |
May | 0.103597E+10 | 0.691353E+09 | 0.208851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14996835.90 | 0.305146E+10 |
June | 0.103308E+10 | 0.675688E+09 | 0.205070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220012E+09 | 0.148022E+10 |
July | 0.959235E+09 | 0.640699E+09 | 0.201460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.531032E+09 | 0.638513E+09 |
August | 0.107774E+10 | 0.722265E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.380086E+09 | 0.117618E+10 |
September | 0.956342E+09 | 0.674425E+09 | 0.197632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 63459583.98 | 0.204848E+10 |
October | 0.994195E+09 | 0.728076E+09 | 0.204803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 860422.92 | 0.314544E+10 |
November | 0.984487E+09 | 0.778960E+09 | 0.200271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.437032E+10 |
December | 0.959235E+09 | 0.801365E+09 | 0.201413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.566996E+10 |
Annual Sum or Average | 0.119305E+11 | 0.864845E+10 | 0.243324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121045E+10 | 0.423060E+11 |
Minimum of Months | 0.901968E+09 | 0.640699E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.638513E+09 |
Maximum of Months | 0.107774E+10 | 0.830922E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.531032E+09 | 0.706622E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.545876E+09 | 0.129620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.292771E+09 |
February | 0.570983E+09 | 0.437388E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.230304E+09 |
March | 0.682256E+09 | 0.492404E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.209721E+09 |
April | 0.605404E+09 | 0.420379E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151604E+09 |
May | 0.655811E+09 | 0.436264E+09 | 0.132212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 368214.02 | 0.158371E+09 |
June | 0.653980E+09 | 0.424135E+09 | 0.129818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1864958.45 | 80992077.09 |
July | 0.607235E+09 | 0.404466E+09 | 0.127533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6463765.91 | 57104990.66 |
August | 0.682256E+09 | 0.455908E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5481951.08 | 60356902.88 |
September | 0.605404E+09 | 0.429910E+09 | 0.125110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3428296.88 | 0.108143E+09 |
October | 0.629366E+09 | 0.473985E+09 | 0.129649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23460.33 | 0.155558E+09 |
November | 0.623221E+09 | 0.507544E+09 | 0.126780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.211889E+09 |
December | 0.607235E+09 | 0.525651E+09 | 0.127503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.264193E+09 |
Annual Sum or Average | 0.755252E+10 | 0.555391E+10 | 0.154035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 17630646.66 | 0.198101E+10 |
Minimum of Months | 0.570983E+09 | 0.404466E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57104990.66 |
Maximum of Months | 0.682256E+09 | 0.545876E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6463765.91 | 0.292771E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.891464E+09 | 0.204758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.681340E+09 |
February | 0.901968E+09 | 0.710238E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.532963E+09 |
March | 0.107774E+10 | 0.783810E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.491271E+09 |
April | 0.956342E+09 | 0.662339E+09 | 0.197726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.356227E+09 |
May | 0.103597E+10 | 0.687673E+09 | 0.208852E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 864503.83 | 0.365033E+09 |
June | 0.103308E+10 | 0.669543E+09 | 0.205071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4465638.46 | 0.186646E+09 |
July | 0.959235E+09 | 0.636928E+09 | 0.201461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15443725.87 | 0.126820E+09 |
August | 0.107774E+10 | 0.717147E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13003061.48 | 0.137381E+09 |
September | 0.956342E+09 | 0.680368E+09 | 0.197634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8133535.15 | 0.243641E+09 |
October | 0.994195E+09 | 0.761506E+09 | 0.204804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 117726.43 | 0.346089E+09 |
November | 0.984487E+09 | 0.837212E+09 | 0.200273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.480178E+09 |
December | 0.959235E+09 | 0.871754E+09 | 0.201415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.603577E+09 |
Annual Sum or Average | 0.119305E+11 | 0.890998E+10 | 0.243325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 42028191.22 | 0.455116E+10 |
Minimum of Months | 0.901968E+09 | 0.636928E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126820E+09 |
Maximum of Months | 0.107774E+10 | 0.891464E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15443725.87 | 0.681340E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.465148E+09 | 0.541101E+09 | 0.129621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.457038E+09 |
February | 0.421807E+09 | 0.438776E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.362397E+09 |
March | 0.502994E+09 | 0.489006E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.332499E+09 |
April | 0.447140E+09 | 0.416629E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.242577E+09 |
May | 0.484071E+09 | 0.436811E+09 | 0.132213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 612528.62 | 0.242472E+09 |
June | 0.482240E+09 | 0.428518E+09 | 0.129819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3036667.04 | 0.125277E+09 |
July | 0.448971E+09 | 0.404635E+09 | 0.127534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10134465.89 | 86152659.19 |
August | 0.502994E+09 | 0.456541E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8610279.83 | 92308815.42 |
September | 0.447140E+09 | 0.427159E+09 | 0.125111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5319077.55 | 0.164345E+09 |
October | 0.465148E+09 | 0.467940E+09 | 0.129650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34688.47 | 0.235628E+09 |
November | 0.460569E+09 | 0.511979E+09 | 0.126781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.322128E+09 |
December | 0.448971E+09 | 0.528006E+09 | 0.127504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.405694E+09 |
Annual Sum or Average | 0.557719E+10 | 0.554710E+10 | 0.154036E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 27747707.41 | 0.306852E+10 |
Minimum of Months | 0.421807E+09 | 0.404635E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 86152659.19 |
Maximum of Months | 0.502994E+09 | 0.541101E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10134465.89 | 0.457038E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.832446E+09 | 0.204757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.708759E+09 |
February | 0.901968E+09 | 0.675230E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.575124E+09 |
March | 0.107774E+10 | 0.770859E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.516952E+09 |
April | 0.956342E+09 | 0.662781E+09 | 0.197725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.372784E+09 |
May | 0.103597E+10 | 0.692191E+09 | 0.208851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 866571.60 | 0.370030E+09 |
June | 0.103308E+10 | 0.676582E+09 | 0.205070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4429243.26 | 0.187280E+09 |
July | 0.959235E+09 | 0.641434E+09 | 0.201460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14541550.68 | 0.128424E+09 |
August | 0.107774E+10 | 0.723314E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12621505.61 | 0.140837E+09 |
September | 0.956342E+09 | 0.675673E+09 | 0.197632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7126378.45 | 0.253374E+09 |
October | 0.994195E+09 | 0.729461E+09 | 0.204803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45606.89 | 0.374733E+09 |
November | 0.984487E+09 | 0.780932E+09 | 0.200271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.509455E+09 |
December | 0.959235E+09 | 0.804817E+09 | 0.201413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.640361E+09 |
Annual Sum or Average | 0.119305E+11 | 0.866572E+10 | 0.243324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 39630856.48 | 0.477811E+10 |
Minimum of Months | 0.901968E+09 | 0.641434E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128424E+09 |
Maximum of Months | 0.107774E+10 | 0.832446E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14541550.68 | 0.708759E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.547834E+09 | 0.129620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.455888E+09 |
February | 0.570983E+09 | 0.438492E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.362165E+09 |
March | 0.682256E+09 | 0.493866E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.332731E+09 |
April | 0.605404E+09 | 0.421217E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.244427E+09 |
May | 0.655811E+09 | 0.436887E+09 | 0.132212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 567901.66 | 0.249183E+09 |
June | 0.653980E+09 | 0.424533E+09 | 0.129818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2906214.93 | 0.126917E+09 |
July | 0.607235E+09 | 0.404856E+09 | 0.127533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9960645.01 | 88001439.32 |
August | 0.682256E+09 | 0.456578E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8586816.42 | 93202725.13 |
September | 0.605404E+09 | 0.430933E+09 | 0.125110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5404490.40 | 0.164214E+09 |
October | 0.629366E+09 | 0.475940E+09 | 0.129649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 42796.31 | 0.234382E+09 |
November | 0.623221E+09 | 0.509622E+09 | 0.126780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323027E+09 |
December | 0.607235E+09 | 0.527360E+09 | 0.127503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.405381E+09 |
Annual Sum or Average | 0.755252E+10 | 0.556812E+10 | 0.154035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 27468864.74 | 0.307952E+10 |
Minimum of Months | 0.570983E+09 | 0.404856E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88001439.32 |
Maximum of Months | 0.682256E+09 | 0.547834E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9960645.01 | 0.455888E+09 |
Report: SpaceGainsMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.932464E+09 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.748343E+09 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.683424E+09 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.495282E+09 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 817800.67 | 0.499516E+09 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4462500.33 | 0.252634E+09 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17167772.34 | 0.172131E+09 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14615292.06 | 0.188661E+09 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9235681.23 | 0.342317E+09 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14542.91 | 0.498184E+09 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.686414E+09 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.855795E+09 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46313589.55 | 0.635516E+10 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.172131E+09 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17167772.34 | 0.932464E+09 |
Report: SpaceGainsMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115277E+10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.917517E+09 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.847492E+09 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.616676E+09 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1100207.75 | 0.625626E+09 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5826071.96 | 0.320942E+09 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22570859.42 | 0.217712E+09 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19060414.27 | 0.237802E+09 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12289862.24 | 0.425167E+09 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36188.86 | 0.601720E+09 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.828338E+09 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103774E+10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60883604.50 | 0.782950E+10 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.217712E+09 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22570859.42 | 0.115277E+10 |
Report: SpaceGainsMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117982E+10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.924821E+09 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.864691E+09 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.629596E+09 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 665421.21 | 0.644153E+09 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4830846.43 | 0.336221E+09 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18609955.53 | 0.225304E+09 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17266803.24 | 0.242789E+09 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10090296.94 | 0.426548E+09 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.594632E+09 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.817752E+09 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103935E+10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51463323.35 | 0.792568E+10 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.225304E+09 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18609955.53 | 0.117982E+10 |
Report: PeakSpaceGainsMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 6443.98 | 02-JAN-08:09 | 14019.75 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 6443.98 | 01-FEB-08:09 | 14019.75 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 6443.98 | 01-MAR-08:09 | 14019.75 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 6443.98 | 03-APR-07:10 | 14019.75 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 6443.98 | 01-MAY-07:10 | 14019.75 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 6443.98 | 01-JUN-07:10 | 14019.75 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 6443.98 | 03-JUL-07:10 | 14019.75 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 6443.98 | 01-AUG-07:10 | 14019.75 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 6443.98 | 01-SEP-07:10 | 14019.75 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 6443.98 | 02-OCT-07:10 | 14019.75 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 6443.98 | 01-NOV-07:10 | 14019.75 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 6443.98 | 01-DEC-08:09 | 14019.75 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 6443.98 | 14019.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 6443.98 | 14019.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 6443.98 | 02-JAN-08:09 | 6808.32 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 6443.98 | 01-FEB-08:09 | 6808.32 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 6443.98 | 01-MAR-08:09 | 6808.32 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 6443.98 | 03-APR-07:10 | 6808.32 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 6443.98 | 01-MAY-07:10 | 6808.32 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 6443.98 | 01-JUN-07:10 | 6808.32 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 6443.98 | 03-JUL-07:10 | 6808.32 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 6443.98 | 01-AUG-07:10 | 6808.32 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 6443.98 | 01-SEP-07:10 | 6808.32 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 6443.98 | 02-OCT-07:10 | 6808.32 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 6443.98 | 01-NOV-07:10 | 6808.32 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 6443.98 | 01-DEC-08:09 | 6808.32 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 6443.98 | 02-JAN-08:09 | 6808.32 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 6443.98 | 01-FEB-08:09 | 6808.32 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 6443.98 | 01-MAR-08:09 | 6808.32 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 6443.98 | 03-APR-07:10 | 6808.32 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 6443.98 | 01-MAY-07:10 | 6808.32 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 6443.98 | 01-JUN-07:10 | 6808.32 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 6443.98 | 03-JUL-07:10 | 6808.32 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 6443.98 | 01-AUG-07:10 | 6808.32 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 6443.98 | 01-SEP-07:10 | 6808.32 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 6443.98 | 02-OCT-07:10 | 6808.32 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 6443.98 | 01-NOV-07:10 | 6808.32 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 6443.98 | 01-DEC-08:09 | 6808.32 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1358.45 | 02-JAN-08:09 | 1435.25 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1443.38 | 05-JAN-22:01 |
February | 1306.65 | 01-FEB-10:09 | 1358.45 | 01-FEB-08:09 | 1435.25 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 793.77 | 08-FEB-22:02 |
March | 1306.65 | 01-MAR-10:09 | 1358.45 | 17-MAR-07:10 | 1435.25 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1021.00 | 02-MAR-23:00 |
April | 1306.65 | 03-APR-09:09 | 1184.79 | 14-APR-07:10 | 1435.25 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 710.96 | 27-APR-02:00 |
May | 1306.65 | 01-MAY-09:09 | 947.97 | 03-MAY-07:10 | 1435.25 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.95 | 20-MAY-17:03 | 1353.16 | 22-MAY-04:03 |
June | 1306.65 | 01-JUN-09:09 | 711.15 | 16-JUN-07:10 | 1435.25 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.29 | 29-JUN-15:00 | 578.33 | 14-JUN-02:00 |
July | 1306.65 | 03-JUL-09:09 | 774.31 | 07-JUL-07:19 | 1435.25 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 156.29 | 30-JUL-12:00 | 341.52 | 05-JUL-01:00 |
August | 1306.65 | 01-AUG-09:09 | 774.31 | 17-AUG-07:10 | 1435.25 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 187.85 | 06-AUG-17:36 | 419.92 | 23-AUG-03:00 |
September | 1306.65 | 01-SEP-09:09 | 1184.79 | 11-SEP-07:10 | 1435.25 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 215.78 | 03-SEP-13:00 | 751.79 | 12-SEP-03:00 |
October | 1306.65 | 02-OCT-09:09 | 1358.45 | 25-OCT-07:10 | 1435.25 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.44 | 15-OCT-14:00 | 631.41 | 30-OCT-22:00 |
November | 1306.65 | 01-NOV-09:09 | 1358.45 | 01-NOV-07:10 | 1435.25 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 803.91 | 29-NOV-22:03 |
December | 1306.65 | 01-DEC-10:09 | 1358.45 | 01-DEC-08:09 | 1435.25 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1101.55 | 01-DEC-05:05 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 711.15 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 341.52 | |||||
Maximum of Months | 1306.65 | 1358.45 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 215.78 | 1443.38 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.22 | 02-JAN-10:09 | 860.01 | 02-JAN-08:09 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 962.04 | 05-JAN-22:01 |
February | 827.22 | 01-FEB-10:09 | 750.07 | 01-FEB-16:00 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 528.85 | 08-FEB-22:02 |
March | 827.22 | 01-MAR-10:09 | 860.01 | 17-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 679.95 | 02-MAR-23:00 |
April | 827.22 | 03-APR-09:09 | 600.14 | 14-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 473.27 | 27-APR-02:00 |
May | 827.22 | 01-MAY-09:09 | 490.21 | 03-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 41.83 | 20-MAY-17:03 | 897.08 | 22-MAY-04:03 |
June | 827.22 | 01-JUN-09:09 | 410.22 | 01-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.86 | 29-JUN-15:00 | 379.99 | 14-JUN-02:00 |
July | 827.22 | 03-JUL-09:09 | 450.21 | 03-JUL-15:20 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 98.86 | 30-JUL-14:30 | 226.65 | 05-JUL-01:00 |
August | 827.22 | 01-AUG-09:09 | 490.21 | 17-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 130.41 | 06-AUG-17:38 | 278.45 | 23-AUG-03:00 |
September | 827.22 | 01-SEP-09:09 | 600.14 | 13-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 153.45 | 03-SEP-13:00 | 495.70 | 12-SEP-03:00 |
October | 827.22 | 02-OCT-09:09 | 860.01 | 25-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.74 | 15-OCT-14:00 | 422.39 | 30-OCT-22:00 |
November | 827.22 | 01-NOV-09:09 | 860.01 | 01-NOV-07:10 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 535.48 | 29-NOV-22:03 |
December | 827.22 | 01-DEC-10:09 | 860.01 | 01-DEC-08:09 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 729.15 | 01-DEC-05:08 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 226.65 | |||||
Maximum of Months | 827.22 | 860.01 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 153.45 | 962.04 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1358.45 | 02-JAN-08:09 | 1435.24 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1443.90 | 05-JAN-22:01 |
February | 1306.65 | 01-FEB-10:09 | 1121.62 | 02-FEB-08:09 | 1435.24 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 810.90 | 19-FEB-13:00 |
March | 1306.65 | 01-MAR-10:09 | 1358.45 | 17-MAR-07:10 | 1435.24 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1050.68 | 02-MAR-23:00 |
April | 1306.65 | 03-APR-09:09 | 1184.79 | 14-APR-07:10 | 1435.24 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 715.43 | 27-APR-02:00 |
May | 1306.65 | 01-MAY-09:09 | 947.97 | 03-MAY-07:10 | 1435.24 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 54.90 | 20-MAY-17:03 | 1357.47 | 22-MAY-04:03 |
June | 1306.65 | 01-JUN-09:09 | 711.15 | 01-JUN-07:10 | 1435.24 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.29 | 29-JUN-15:00 | 574.87 | 14-JUN-02:00 |
July | 1306.65 | 03-JUL-09:09 | 774.31 | 07-JUL-07:19 | 1435.24 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 140.72 | 30-JUL-14:30 | 343.86 | 05-JUL-01:00 |
August | 1306.65 | 01-AUG-09:09 | 774.31 | 17-AUG-07:10 | 1435.24 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 190.79 | 06-AUG-17:36 | 425.35 | 23-AUG-03:00 |
September | 1306.65 | 01-SEP-09:09 | 1184.79 | 11-SEP-07:10 | 1435.24 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 201.29 | 03-SEP-13:00 | 751.12 | 12-SEP-03:00 |
October | 1306.65 | 02-OCT-09:09 | 1358.45 | 25-OCT-07:10 | 1435.24 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.53 | 18-OCT-14:00 | 662.50 | 30-OCT-22:00 |
November | 1306.65 | 01-NOV-09:09 | 1358.45 | 01-NOV-07:10 | 1435.24 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 804.23 | 29-NOV-22:03 |
December | 1306.65 | 01-DEC-10:09 | 1358.45 | 01-DEC-08:09 | 1435.24 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1093.75 | 01-DEC-05:07 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 711.15 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 343.86 | |||||
Maximum of Months | 1306.65 | 1358.45 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 201.29 | 1443.90 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 859.95 | 02-JAN-08:09 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 961.80 | 05-JAN-22:01 |
February | 827.17 | 01-FEB-10:09 | 859.95 | 01-FEB-08:09 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 529.47 | 08-FEB-22:02 |
March | 827.17 | 01-MAR-10:09 | 859.95 | 17-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 689.97 | 02-MAR-23:00 |
April | 827.17 | 03-APR-09:09 | 750.02 | 14-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 473.23 | 27-APR-02:00 |
May | 827.17 | 01-MAY-09:09 | 600.10 | 03-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.21 | 20-MAY-17:03 | 895.34 | 22-MAY-04:03 |
June | 827.17 | 01-JUN-09:09 | 450.19 | 01-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.86 | 29-JUN-15:00 | 386.17 | 14-JUN-02:00 |
July | 827.17 | 03-JUL-09:09 | 490.17 | 07-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 128.17 | 30-JUL-12:00 | 234.89 | 05-JUL-01:00 |
August | 827.17 | 01-AUG-09:09 | 600.10 | 17-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 131.11 | 06-AUG-17:36 | 281.50 | 23-AUG-03:00 |
September | 827.17 | 01-SEP-09:09 | 750.02 | 11-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 162.73 | 03-SEP-13:00 | 492.66 | 12-SEP-03:00 |
October | 827.17 | 02-OCT-09:09 | 859.95 | 25-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13.59 | 15-OCT-12:40 | 425.77 | 30-OCT-22:00 |
November | 827.17 | 01-NOV-09:09 | 859.95 | 01-NOV-07:10 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 535.41 | 29-NOV-22:03 |
December | 827.17 | 01-DEC-10:09 | 859.95 | 01-DEC-08:09 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 729.15 | 01-DEC-05:08 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 450.19 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 234.89 | |||||
Maximum of Months | 827.17 | 859.95 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 162.73 | 961.80 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1358.45 | 02-JAN-08:09 | 1435.25 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 769.10 | 05-JAN-22:01 |
February | 1306.65 | 01-FEB-10:09 | 1184.79 | 01-FEB-08:09 | 1435.25 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 434.90 | 17-FEB-04:00 |
March | 1306.65 | 01-MAR-10:09 | 1358.45 | 17-MAR-07:10 | 1435.25 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 552.30 | 02-MAR-23:00 |
April | 1306.65 | 03-APR-09:09 | 1011.14 | 14-APR-07:10 | 1435.25 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 383.85 | 27-APR-02:00 |
May | 1306.65 | 01-MAY-09:09 | 947.97 | 03-MAY-07:10 | 1435.25 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.17 | 20-MAY-17:03 | 785.15 | 22-MAY-04:00 |
June | 1306.65 | 01-JUN-09:09 | 711.15 | 16-JUN-07:10 | 1435.25 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.22 | 29-JUN-15:00 | 321.17 | 14-JUN-02:00 |
July | 1306.65 | 03-JUL-09:09 | 774.31 | 07-JUL-07:30 | 1435.25 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 99.14 | 30-JUL-12:00 | 190.33 | 05-JUL-01:00 |
August | 1306.65 | 01-AUG-09:09 | 774.31 | 17-AUG-07:10 | 1435.25 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 106.80 | 06-AUG-17:50 | 240.73 | 23-AUG-03:00 |
September | 1306.65 | 01-SEP-09:09 | 1184.79 | 11-SEP-07:10 | 1435.25 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 129.18 | 03-SEP-13:00 | 447.87 | 12-SEP-03:00 |
October | 1306.65 | 02-OCT-09:09 | 1358.45 | 25-OCT-07:10 | 1435.25 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.76 | 15-OCT-14:00 | 365.34 | 30-OCT-22:00 |
November | 1306.65 | 01-NOV-09:09 | 1358.45 | 01-NOV-07:10 | 1435.25 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 429.77 | 29-NOV-22:03 |
December | 1306.65 | 01-DEC-10:09 | 1358.45 | 01-DEC-08:09 | 1435.25 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 647.79 | 01-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 711.15 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 190.33 | |||||
Maximum of Months | 1306.65 | 1358.45 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 129.18 | 785.15 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.22 | 02-JAN-10:09 | 860.01 | 02-JAN-08:09 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 512.63 | 05-JAN-22:01 |
February | 827.22 | 01-FEB-10:09 | 750.07 | 01-FEB-16:00 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 291.69 | 17-FEB-04:00 |
March | 827.22 | 01-MAR-10:09 | 860.01 | 17-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 372.95 | 02-MAR-23:00 |
April | 827.22 | 03-APR-09:09 | 600.14 | 14-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 266.10 | 27-APR-02:00 |
May | 827.22 | 01-MAY-09:09 | 490.21 | 03-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.76 | 20-MAY-17:03 | 525.32 | 22-MAY-04:00 |
June | 827.22 | 01-JUN-09:09 | 410.22 | 01-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.14 | 29-JUN-15:00 | 215.88 | 14-JUN-02:00 |
July | 827.22 | 03-JUL-09:09 | 450.21 | 07-JUL-07:19 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.32 | 30-JUL-12:00 | 130.58 | 05-JUL-01:00 |
August | 827.22 | 01-AUG-09:09 | 450.21 | 17-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.80 | 06-AUG-17:30 | 165.67 | 23-AUG-03:00 |
September | 827.22 | 01-SEP-09:09 | 600.14 | 13-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.81 | 03-SEP-12:52 | 298.51 | 12-SEP-03:00 |
October | 827.22 | 02-OCT-09:09 | 860.01 | 25-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2.45 | 18-OCT-14:00 | 249.08 | 30-OCT-22:00 |
November | 827.22 | 01-NOV-09:09 | 860.01 | 01-NOV-07:10 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 286.79 | 26-NOV-20:00 |
December | 827.22 | 01-DEC-10:09 | 860.01 | 01-DEC-08:09 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 429.04 | 01-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 130.58 | |||||
Maximum of Months | 827.22 | 860.01 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 74.81 | 525.32 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1358.45 | 02-JAN-08:09 | 1435.24 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 37274.45 | 10-JAN-17:01 |
February | 1306.65 | 01-FEB-10:09 | 1121.62 | 02-FEB-08:09 | 1435.24 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 36495.48 | 01-FEB-07:01 |
March | 1306.65 | 01-MAR-10:09 | 1358.45 | 17-MAR-07:10 | 1435.24 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 30548.19 | 06-MAR-07:01 |
April | 1306.65 | 03-APR-09:09 | 1011.14 | 14-APR-07:10 | 1435.24 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 19413.59 | 28-APR-06:01 |
May | 1306.65 | 01-MAY-09:09 | 947.97 | 03-MAY-07:10 | 1435.24 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2494.51 | 19-MAY-16:10 | 17421.01 | 08-MAY-06:01 |
June | 1306.65 | 01-JUN-09:09 | 711.15 | 16-JUN-07:10 | 1435.24 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4898.78 | 28-JUN-16:10 | 13433.63 | 16-JUN-06:03 |
July | 1306.65 | 03-JUL-09:09 | 774.31 | 07-JUL-07:30 | 1435.24 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8602.14 | 17-JUL-16:03 | 9253.48 | 05-JUL-06:02 |
August | 1306.65 | 01-AUG-09:09 | 774.31 | 17-AUG-07:10 | 1435.24 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5570.89 | 10-AUG-17:00 | 11270.71 | 28-AUG-06:02 |
September | 1306.65 | 01-SEP-09:09 | 947.97 | 11-SEP-07:10 | 1435.24 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2958.58 | 01-SEP-16:10 | 13816.48 | 19-SEP-06:03 |
October | 1306.65 | 02-OCT-09:09 | 1358.45 | 25-OCT-07:10 | 1435.24 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.08 | 18-OCT-14:40 | 20429.73 | 10-OCT-06:01 |
November | 1306.65 | 01-NOV-09:09 | 1358.45 | 01-NOV-07:10 | 1435.24 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 26748.71 | 27-NOV-07:01 |
December | 1306.65 | 01-DEC-10:09 | 1358.45 | 01-DEC-08:09 | 1435.24 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 36195.61 | 29-DEC-07:01 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 711.15 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9253.48 | |||||
Maximum of Months | 1306.65 | 1358.45 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 8602.14 | 37274.45 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 859.95 | 02-JAN-08:09 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 512.56 | 05-JAN-22:01 |
February | 827.17 | 01-FEB-10:09 | 859.95 | 02-FEB-08:09 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 294.53 | 17-FEB-04:00 |
March | 827.17 | 01-MAR-10:09 | 859.95 | 17-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 381.65 | 02-MAR-23:00 |
April | 827.17 | 03-APR-09:09 | 750.02 | 14-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 264.19 | 27-APR-02:00 |
May | 827.17 | 01-MAY-09:09 | 600.10 | 03-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22.70 | 20-MAY-17:03 | 526.13 | 22-MAY-04:00 |
June | 827.17 | 01-JUN-09:09 | 450.19 | 01-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.14 | 29-JUN-15:00 | 218.58 | 14-JUN-02:00 |
July | 827.17 | 03-JUL-09:09 | 490.17 | 07-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.81 | 30-JUL-12:00 | 133.54 | 05-JUL-01:00 |
August | 827.17 | 01-AUG-09:09 | 600.10 | 17-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.28 | 06-AUG-17:24 | 166.05 | 23-AUG-03:00 |
September | 827.17 | 01-SEP-09:09 | 750.02 | 11-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 84.20 | 03-SEP-12:52 | 298.64 | 12-SEP-03:00 |
October | 827.17 | 02-OCT-09:09 | 859.95 | 25-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2.46 | 18-OCT-14:00 | 250.59 | 30-OCT-22:00 |
November | 827.17 | 01-NOV-09:09 | 859.95 | 01-NOV-07:10 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 286.99 | 26-NOV-20:00 |
December | 827.17 | 01-DEC-10:09 | 859.95 | 01-DEC-08:09 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 432.16 | 01-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 450.19 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 133.54 | |||||
Maximum of Months | 827.17 | 859.95 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 84.20 | 526.13 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1358.45 | 02-JAN-08:09 | 1435.25 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1204.41 | 05-JAN-22:01 |
February | 1306.65 | 01-FEB-10:09 | 1358.45 | 01-FEB-08:09 | 1435.25 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 683.72 | 17-FEB-04:00 |
March | 1306.65 | 01-MAR-10:09 | 1358.45 | 17-MAR-07:10 | 1435.25 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 885.42 | 02-MAR-23:00 |
April | 1306.65 | 03-APR-09:09 | 1184.79 | 14-APR-07:10 | 1435.25 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 626.76 | 27-APR-02:00 |
May | 1306.65 | 01-MAY-09:09 | 947.97 | 03-MAY-07:10 | 1435.25 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.10 | 20-MAY-17:03 | 1222.56 | 22-MAY-04:00 |
June | 1306.65 | 01-JUN-09:09 | 711.15 | 16-JUN-07:10 | 1435.25 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.20 | 29-JUN-15:00 | 509.91 | 14-JUN-02:00 |
July | 1306.65 | 03-JUL-09:09 | 774.31 | 07-JUL-07:19 | 1435.25 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 130.22 | 30-JUL-12:00 | 301.02 | 05-JUL-01:00 |
August | 1306.65 | 01-AUG-09:09 | 774.31 | 17-AUG-07:10 | 1435.25 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 160.19 | 06-AUG-18:00 | 377.25 | 23-AUG-03:00 |
September | 1306.65 | 01-SEP-09:09 | 1184.79 | 11-SEP-07:10 | 1435.25 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 186.79 | 03-SEP-13:00 | 678.44 | 12-SEP-03:00 |
October | 1306.65 | 02-OCT-09:09 | 1358.45 | 25-OCT-07:10 | 1435.25 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22.38 | 15-OCT-14:00 | 563.32 | 30-OCT-22:00 |
November | 1306.65 | 01-NOV-09:09 | 1358.45 | 01-NOV-07:10 | 1435.25 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 672.74 | 29-NOV-22:03 |
December | 1306.65 | 01-DEC-10:09 | 1358.45 | 01-DEC-08:09 | 1435.25 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 973.77 | 01-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 711.15 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 301.02 | |||||
Maximum of Months | 1306.65 | 1358.45 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 186.79 | 1222.56 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 805.43 | 02-JAN-08:09 | 860.01 | 02-JAN-08:09 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 802.68 | 05-JAN-22:01 |
February | 805.43 | 01-FEB-08:09 | 750.07 | 01-FEB-16:00 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 454.00 | 17-FEB-04:00 |
March | 805.43 | 01-MAR-08:09 | 860.01 | 17-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 588.30 | 02-MAR-23:00 |
April | 805.43 | 03-APR-07:10 | 600.14 | 14-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 416.54 | 27-APR-02:00 |
May | 805.43 | 01-MAY-07:10 | 490.21 | 03-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.05 | 20-MAY-17:03 | 810.86 | 22-MAY-04:00 |
June | 805.43 | 01-JUN-07:10 | 410.22 | 01-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.80 | 29-JUN-15:00 | 335.55 | 14-JUN-02:00 |
July | 805.43 | 03-JUL-07:10 | 450.21 | 03-JUL-15:20 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 84.28 | 30-JUL-12:20 | 199.59 | 05-JUL-01:00 |
August | 805.43 | 01-AUG-07:10 | 490.21 | 17-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.72 | 06-AUG-18:00 | 250.11 | 23-AUG-03:00 |
September | 805.43 | 01-SEP-07:10 | 600.14 | 13-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 118.94 | 03-SEP-13:00 | 447.81 | 12-SEP-03:00 |
October | 805.43 | 02-OCT-07:10 | 860.01 | 25-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.09 | 18-OCT-14:00 | 374.06 | 30-OCT-22:00 |
November | 805.43 | 01-NOV-07:10 | 860.01 | 01-NOV-07:10 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 448.10 | 29-NOV-22:03 |
December | 805.43 | 01-DEC-08:09 | 860.01 | 01-DEC-08:09 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 644.29 | 01-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 805.43 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 199.59 | |||||
Maximum of Months | 805.43 | 860.01 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 118.94 | 810.86 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1358.45 | 02-JAN-08:09 | 1435.24 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1204.72 | 05-JAN-22:01 |
February | 1306.65 | 01-FEB-10:09 | 1121.62 | 02-FEB-08:09 | 1435.24 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 729.08 | 19-FEB-12:40 |
March | 1306.65 | 01-MAR-10:09 | 1358.45 | 17-MAR-07:10 | 1435.24 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 910.22 | 02-MAR-23:00 |
April | 1306.65 | 03-APR-09:09 | 1184.79 | 14-APR-07:10 | 1435.24 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 630.06 | 27-APR-02:00 |
May | 1306.65 | 01-MAY-09:09 | 947.97 | 03-MAY-07:10 | 1435.24 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 47.80 | 20-MAY-17:03 | 1226.30 | 22-MAY-04:00 |
June | 1306.65 | 01-JUN-09:09 | 711.15 | 01-JUN-07:10 | 1435.24 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.20 | 29-JUN-15:00 | 507.91 | 14-JUN-02:00 |
July | 1306.65 | 03-JUL-09:09 | 774.31 | 07-JUL-07:19 | 1435.24 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.88 | 30-JUL-12:18 | 302.86 | 05-JUL-01:00 |
August | 1306.65 | 01-AUG-09:09 | 774.31 | 17-AUG-07:10 | 1435.24 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 160.57 | 06-AUG-17:56 | 381.90 | 23-AUG-03:00 |
September | 1306.65 | 01-SEP-09:09 | 1184.79 | 11-SEP-07:10 | 1435.24 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 168.22 | 03-SEP-12:55 | 679.33 | 12-SEP-03:00 |
October | 1306.65 | 02-OCT-09:09 | 1358.45 | 25-OCT-07:10 | 1435.24 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5.56 | 18-OCT-14:30 | 588.04 | 30-OCT-22:00 |
November | 1306.65 | 01-NOV-09:09 | 1358.45 | 01-NOV-07:10 | 1435.24 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 675.98 | 26-NOV-13:45 |
December | 1306.65 | 01-DEC-10:09 | 1358.45 | 01-DEC-08:09 | 1435.24 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 989.68 | 01-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 711.15 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 302.86 | |||||
Maximum of Months | 1306.65 | 1358.45 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 168.22 | 1226.30 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 859.95 | 02-JAN-08:09 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 802.55 | 05-JAN-22:01 |
February | 827.17 | 01-FEB-10:09 | 859.95 | 01-FEB-08:09 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 457.44 | 17-FEB-04:00 |
March | 827.17 | 01-MAR-10:09 | 859.95 | 17-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 596.89 | 02-MAR-23:00 |
April | 827.17 | 03-APR-09:09 | 750.02 | 14-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 417.60 | 27-APR-02:00 |
May | 827.17 | 01-MAY-09:09 | 600.10 | 03-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.21 | 20-MAY-17:03 | 809.43 | 22-MAY-04:00 |
June | 827.17 | 01-JUN-09:09 | 450.19 | 01-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.80 | 29-JUN-15:00 | 340.65 | 14-JUN-02:00 |
July | 827.17 | 03-JUL-09:09 | 490.17 | 07-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 103.95 | 30-JUL-12:00 | 206.55 | 05-JUL-01:00 |
August | 827.17 | 01-AUG-09:09 | 600.10 | 17-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 117.92 | 06-AUG-12:00 | 252.79 | 23-AUG-03:00 |
September | 827.17 | 01-SEP-09:09 | 750.02 | 11-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 135.74 | 03-SEP-12:52 | 446.08 | 12-SEP-03:00 |
October | 827.17 | 02-OCT-09:09 | 859.95 | 25-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3.74 | 18-OCT-14:00 | 377.53 | 30-OCT-22:00 |
November | 827.17 | 01-NOV-09:09 | 859.95 | 01-NOV-07:10 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 448.05 | 29-NOV-22:03 |
December | 827.17 | 01-DEC-10:09 | 859.95 | 01-DEC-08:09 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 646.62 | 01-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 450.19 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 206.55 | |||||
Maximum of Months | 827.17 | 859.95 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 135.74 | 809.43 |
Report: PeakSpaceGainsMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1534.95 | 05-JAN-22:01 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 991.47 | 17-FEB-04:00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1228.61 | 02-MAR-23:00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 868.04 | 27-APR-02:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.76 | 20-MAY-17:03 | 1761.93 | 22-MAY-04:07 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.04 | 29-JUN-15:00 | 702.73 | 14-JUN-02:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 174.49 | 30-JUL-12:00 | 413.98 | 05-JUL-01:00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 190.68 | 06-AUG-17:50 | 530.78 | 23-AUG-03:00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 226.32 | 03-SEP-13:00 | 962.41 | 12-SEP-03:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.61 | 18-OCT-14:00 | 798.60 | 30-OCT-22:20 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 930.88 | 26-NOV-20:00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1439.02 | 01-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 413.98 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 226.32 | 1761.93 |
Report: PeakSpaceGainsMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1947.95 | 05-JAN-22:01 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1220.98 | 17-FEB-04:00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1550.19 | 02-MAR-23:00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 1102.86 | 27-APR-02:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.65 | 20-MAY-17:03 | 2187.18 | 22-MAY-04:00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90.52 | 29-JUN-15:00 | 892.38 | 14-JUN-02:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 231.63 | 30-JUL-12:00 | 517.62 | 05-JUL-01:00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 245.98 | 06-AUG-18:00 | 667.09 | 23-AUG-03:00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 299.62 | 03-SEP-13:00 | 1195.57 | 12-SEP-03:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.29 | 18-OCT-14:00 | 982.66 | 30-OCT-22:00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1123.35 | 26-NOV-20:00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1739.85 | 01-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 517.62 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 299.62 | 2187.18 |
Report: PeakSpaceGainsMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 2103.25 | 05-JAN-22:01 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1166.88 | 08-FEB-22:02 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1585.07 | 02-MAR-23:00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 1085.20 | 27-APR-02:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.22 | 20-MAY-17:03 | 2084.70 | 22-MAY-04:03 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.95 | 29-JUN-15:00 | 900.16 | 04-JUN-13:55 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 195.04 | 30-JUL-12:00 | 512.46 | 05-JUL-01:00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 218.73 | 06-AUG-18:00 | 646.85 | 22-AUG-21:03 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 252.89 | 03-SEP-13:00 | 1144.70 | 12-SEP-03:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 972.06 | 30-OCT-21:05 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1159.04 | 29-NOV-22:03 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1583.05 | 01-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 512.46 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 252.89 | 2103.25 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 9950.03 | 19-JAN-16:40 | 6035.01 | 6443.98 | 13991.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 17166.31 | 28-FEB-17:00 | 6035.01 | 6443.98 | 13991.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 17441.30 | 01-MAR-17:00 | 6035.01 | 6443.98 | 13991.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 25152.19 | 25-APR-05:03 | 2541.06 | 846.94 | 29641.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 40985.52 | 30-MAY-05:12 | 3176.32 | 3579.89 | 37051.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 39789.25 | 23-JUN-05:12 | 2541.06 | 2863.91 | 29641.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 40965.23 | 24-JUL-05:12 | 3176.32 | 3579.89 | 37051.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 39816.40 | 15-AUG-05:12 | 2541.06 | 2863.91 | 29641.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 39510.36 | 01-SEP-05:12 | 2541.06 | 2863.91 | 29641.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 36698.11 | 19-OCT-06:02 | 7623.17 | 12888.13 | 61169.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 28911.82 | 06-NOV-06:01 | 4446.85 | 1482.14 | 51872.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 13967.30 | 07-DEC-16:10 | 6035.01 | 6443.98 | 13991.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 9950.03 | 2541.06 | 846.94 | 13991.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 40985.52 | 7623.17 | 12888.13 | 61169.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 346.54 | 14-JAN-13:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 95.41 |
February | 2315.62 | 26-FEB-14:16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 253.22 |
March | 2576.78 | 22-MAR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 105.90 |
April | 6096.98 | 25-APR-15:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.01 |
May | 9189.00 | 19-MAY-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37.80 | 0.00 |
June | 10485.93 | 23-JUN-13:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.70 | 0.00 |
July | 13035.23 | 17-JUL-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 11773.08 | 07-AUG-15:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.72 | 0.00 |
September | 8769.81 | 05-SEP-14:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.83 |
October | 5603.51 | 18-OCT-15:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.38 |
November | 1416.25 | 03-NOV-13:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 86.61 |
December | 106.11 | 09-DEC-17:25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110.98 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 106.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 13035.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37.80 | 253.22 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3795.68 | 26-JAN-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 856.86 |
February | 3873.50 | 04-FEB-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 629.03 |
March | 2957.52 | 03-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 248.46 |
April | 2740.71 | 11-APR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 128.34 |
May | 3236.05 | 19-MAY-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.50 | 0.00 |
June | 4407.61 | 23-JUN-15:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.31 | 0.00 |
July | 6171.05 | 17-JUL-15:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.64 | 0.00 |
August | 6163.94 | 07-AUG-15:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.87 | 0.00 |
September | 5656.49 | 05-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.45 |
October | 2133.81 | 04-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 95.85 |
November | 2633.92 | 09-NOV-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.79 |
December | 3285.04 | 29-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 2133.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 6171.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.50 | 856.86 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3668.93 | 28-JAN-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 576.96 |
February | 3517.90 | 04-FEB-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 502.03 |
March | 3431.01 | 03-MAR-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 193.72 |
April | 3454.21 | 12-APR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.25 |
May | 3525.00 | 30-MAY-06:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.91 |
June | 4625.79 | 23-JUN-15:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.74 | 0.00 |
July | 6399.32 | 17-JUL-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.26 | 0.00 |
August | 6132.49 | 07-AUG-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.46 | 0.00 |
September | 5883.55 | 05-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.95 |
October | 3013.74 | 06-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 53.13 |
November | 2999.89 | 10-NOV-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 122.97 |
December | 3405.28 | 29-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 2999.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 6399.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.26 | 576.96 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6167.90 | 13-JAN-16:50 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 9670.20 | 28-FEB-17:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 9607.38 | 01-MAR-17:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 13138.63 | 25-APR-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 22405.55 | 30-MAY-05:12 | 3176.32 | 3579.89 | 15129.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 29305.31 | 26-JUN-06:02 | 6352.64 | 10740.11 | 15129.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 31376.76 | 17-JUL-06:03 | 3811.58 | 6444.06 | 9077.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 30894.40 | 07-AUG-06:03 | 3811.58 | 6444.06 | 9077.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 31042.92 | 05-SEP-06:03 | 5082.11 | 8592.08 | 12103.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 13815.60 | 18-OCT-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 10203.65 | 03-NOV-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6930.72 | 07-DEC-16:20 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 6167.90 | 3176.32 | 3579.89 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 31376.76 | 6352.64 | 10740.11 | 15129.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6099.79 | 13-JAN-16:50 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 7817.29 | 28-FEB-17:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 8057.57 | 29-MAR-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 14049.25 | 25-APR-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 17126.25 | 19-MAY-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 19298.73 | 23-JUN-14:00 | 6198.29 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 28776.60 | 17-JUL-06:03 | 3811.58 | 6444.06 | 9077.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 28228.98 | 07-AUG-06:03 | 3811.58 | 6444.06 | 9077.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 31941.21 | 05-SEP-06:03 | 5082.11 | 8592.08 | 12103.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 13608.21 | 18-OCT-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 8131.67 | 03-NOV-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6649.44 | 06-DEC-16:20 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 6099.79 | 3811.58 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 31941.21 | 6198.29 | 8592.08 | 12103.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1002.18 | 13-JAN-16:30 | 1272.23 | 1358.45 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 106.72 |
February | 1420.03 | 27-FEB-16:10 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.49 |
March | 1494.31 | 29-MAR-16:00 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 138.99 |
April | 3616.99 | 07-APR-14:30 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.32 |
May | 5439.39 | 19-MAY-16:00 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 44.73 | 0.00 |
June | 6509.26 | 23-JUN-13:50 | 1306.65 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 19.43 | 0.00 |
July | 11965.45 | 16-JUL-18:31 | 0.00 | 251.99 | 2702.72 | 0.00 | 0.00 | 0.00 | 0.00 | 53.42 | 0.00 |
August | 11664.95 | 06-AUG-16:11 | 468.72 | 251.99 | 3348.91 | 0.00 | 0.00 | 0.00 | 0.00 | 158.91 | 0.00 |
September | 10762.11 | 04-SEP-15:41 | 468.72 | 251.99 | 3348.91 | 0.00 | 0.00 | 0.00 | 0.00 | 67.41 | 0.00 |
October | 2862.51 | 19-OCT-14:40 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.61 |
November | 1360.36 | 03-NOV-16:00 | 1272.23 | 947.97 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.31 |
December | 1111.96 | 06-DEC-16:00 | 1272.23 | 1121.62 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 142.61 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1002.18 | 0.00 | 251.99 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 11965.45 | 1306.65 | 1358.45 | 3348.91 | 0.00 | 0.00 | 0.00 | 0.00 | 158.91 | 142.61 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1202.35 | 20-JAN-10:30 | 1654.44 | 820.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 145.62 |
February | 2120.79 | 27-FEB-10:30 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.78 |
March | 4259.72 | 23-MAR-10:00 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 137.69 |
April | 6725.84 | 25-APR-09:20 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.49 |
May | 8174.38 | 19-MAY-08:50 | 805.43 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.16 |
June | 12606.43 | 25-JUN-08:52 | 211.95 | 113.95 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 53.84 |
July | 15427.90 | 16-JUL-09:12 | 254.35 | 136.74 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 53.98 |
August | 15859.34 | 06-AUG-09:31 | 296.74 | 159.53 | 2120.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.92 | 0.00 |
September | 11854.40 | 04-SEP-08:22 | 211.95 | 113.95 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.18 |
October | 4949.16 | 18-OCT-09:40 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.37 |
November | 2006.67 | 03-NOV-09:40 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.31 |
December | 1265.05 | 20-DEC-10:20 | 1654.44 | 820.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64.67 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1202.35 | 211.95 | 113.95 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 15859.34 | 1654.44 | 820.45 | 2120.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.92 | 145.62 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5969.98 | 19-JAN-13:40 | 2544.47 | 1295.96 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 130.20 |
February | 17321.09 | 26-FEB-14:12 | 334.80 | 179.99 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 239.76 |
March | 11938.03 | 01-MAR-13:50 | 1272.23 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.46 |
April | 11506.91 | 25-APR-13:40 | 1306.65 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.63 |
May | 10982.75 | 19-MAY-13:30 | 1306.65 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 19.20 | 0.00 |
June | 10858.28 | 30-JUN-13:30 | 1306.65 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 10.13 | 0.00 |
July | 19004.40 | 16-JUL-15:12 | 401.76 | 215.99 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 73.49 | 0.00 |
August | 20008.08 | 06-AUG-13:32 | 401.76 | 215.99 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 119.85 | 0.00 |
September | 20915.07 | 03-SEP-12:52 | 401.76 | 215.99 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 160.18 | 0.00 |
October | 19624.38 | 15-OCT-13:52 | 334.80 | 179.99 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 131.26 |
November | 12109.11 | 03-NOV-13:30 | 1306.65 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.74 |
December | 6346.43 | 06-DEC-14:30 | 1306.65 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 199.74 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 5969.98 | 334.80 | 179.99 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 20915.07 | 2544.47 | 1295.96 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 160.18 | 239.76 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1681.02 | 13-JAN-15:50 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.18 |
February | 4546.73 | 28-FEB-16:40 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.45 |
March | 5787.66 | 28-MAR-16:00 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 78.93 |
April | 11748.51 | 22-APR-17:05 | 254.33 | 136.73 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.57 |
May | 16724.90 | 28-MAY-17:02 | 0.00 | 136.73 | 1466.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 148.32 |
June | 16731.96 | 18-JUN-17:22 | 0.00 | 136.73 | 1466.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.54 |
July | 17924.56 | 16-JUL-17:11 | 0.00 | 159.52 | 1710.93 | 0.00 | 0.00 | 0.00 | 0.00 | 26.29 | 0.00 |
August | 17162.90 | 06-AUG-16:11 | 296.72 | 159.52 | 2119.99 | 0.00 | 0.00 | 0.00 | 0.00 | 90.70 | 0.00 |
September | 17373.51 | 04-SEP-16:21 | 296.72 | 159.52 | 2119.99 | 0.00 | 0.00 | 0.00 | 0.00 | 30.77 | 0.00 |
October | 6978.25 | 18-OCT-16:00 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 1.62 | 0.00 |
November | 3486.09 | 03-NOV-15:40 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.96 |
December | 1843.86 | 06-DEC-15:50 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 113.12 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1681.02 | 0.00 | 136.73 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 17924.56 | 805.38 | 410.20 | 2119.99 | 0.00 | 0.00 | 0.00 | 0.00 | 90.70 | 148.32 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 931.50 | 14-JAN-17:03 | 200.88 | 226.40 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.95 |
February | 1383.14 | 26-FEB-14:01 | 468.72 | 251.99 | 3348.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.49 |
March | 1271.88 | 29-MAR-16:00 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 66.66 |
April | 1497.54 | 07-APR-14:50 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.85 |
May | 3410.62 | 30-MAY-15:30 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 4772.79 | 29-JUN-15:30 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 35.76 | 0.00 |
July | 8618.25 | 16-JUL-18:21 | 0.00 | 359.98 | 3861.03 | 0.00 | 0.00 | 0.00 | 0.00 | 28.35 | 0.00 |
August | 5638.62 | 09-AUG-14:50 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 17.20 | 0.00 |
September | 8258.04 | 04-SEP-16:11 | 669.60 | 359.98 | 4784.15 | 0.00 | 0.00 | 0.00 | 0.00 | 33.26 | 0.00 |
October | 2551.60 | 19-OCT-14:30 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.00 |
November | 1374.15 | 08-NOV-14:00 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.81 |
December | 1106.26 | 06-DEC-16:00 | 1272.23 | 1121.62 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75.96 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 931.50 | 0.00 | 226.40 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 8618.25 | 1272.23 | 1121.62 | 4784.15 | 0.00 | 0.00 | 0.00 | 0.00 | 35.76 | 75.96 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1023.75 | 20-JAN-10:05 | 1654.44 | 820.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80.76 |
February | 1681.82 | 27-FEB-10:30 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.05 |
March | 2574.42 | 28-MAR-08:40 | 805.43 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.47 |
April | 4347.55 | 25-APR-09:30 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.76 |
May | 5435.04 | 19-MAY-09:20 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.04 |
June | 11001.99 | 25-JUN-08:41 | 296.74 | 159.53 | 2120.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.69 |
July | 13361.62 | 16-JUL-09:01 | 381.52 | 205.11 | 2725.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.93 |
August | 12632.84 | 06-AUG-09:21 | 381.52 | 205.11 | 2725.72 | 0.00 | 0.00 | 0.00 | 0.00 | 5.73 | 0.00 |
September | 12594.87 | 04-SEP-08:51 | 296.74 | 159.53 | 2120.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.78 |
October | 4172.93 | 18-OCT-09:40 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.98 |
November | 2064.32 | 03-NOV-09:15 | 1654.44 | 820.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.82 |
December | 1108.81 | 06-DEC-10:40 | 1654.44 | 820.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.07 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1023.75 | 296.74 | 159.53 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 13361.62 | 1654.44 | 820.45 | 2725.72 | 0.00 | 0.00 | 0.00 | 0.00 | 5.73 | 80.76 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2702.70 | 14-JAN-12:30 | 137.54 | 107.99 | 558.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55.72 |
February | 15374.55 | 26-FEB-14:01 | 468.72 | 251.99 | 3348.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 132.35 |
March | 8121.59 | 01-MAR-13:20 | 2544.47 | 1295.96 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1833.93 |
April | 6742.46 | 25-APR-12:07 | 3816.70 | 1943.94 | 4305.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 859.72 |
May | 7864.82 | 19-MAY-14:00 | 1306.65 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 309.56 | 0.00 |
June | 11228.10 | 29-JUN-12:00 | 687.71 | 647.98 | 1275.77 | 0.00 | 0.00 | 0.00 | 0.00 | 4596.94 | 0.00 |
July | 15848.68 | 16-JUL-12:22 | 401.76 | 215.99 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 4.52 | 0.00 |
August | 15978.44 | 06-AUG-13:21 | 535.68 | 287.98 | 3827.30 | 0.00 | 0.00 | 0.00 | 0.00 | 65.31 | 0.00 |
September | 17078.35 | 04-SEP-14:51 | 535.68 | 287.98 | 3827.30 | 0.00 | 0.00 | 0.00 | 0.00 | 26.06 | 0.00 |
October | 16717.50 | 15-OCT-15:02 | 401.76 | 215.99 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97.66 |
November | 10135.84 | 03-NOV-12:07 | 3816.70 | 1943.94 | 4305.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1155.52 |
December | 3878.24 | 02-DEC-13:30 | 133.92 | 107.99 | 558.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 127.55 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2702.70 | 133.92 | 107.99 | 558.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 17078.35 | 3816.70 | 1943.94 | 4305.71 | 0.00 | 0.00 | 0.00 | 0.00 | 4596.94 | 1833.93 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1282.85 | 13-JAN-16:00 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.47 |
February | 3492.70 | 28-FEB-16:50 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.04 |
March | 3743.63 | 28-MAR-17:30 | 84.78 | 136.73 | 403.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.35 |
April | 5897.29 | 25-APR-17:30 | 84.78 | 136.73 | 403.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.10 |
May | 13594.98 | 28-MAY-18:52 | 0.00 | 136.73 | 1466.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69.36 |
June | 11426.43 | 24-JUN-17:42 | 254.33 | 136.73 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.50 |
July | 15124.15 | 16-JUL-18:21 | 0.00 | 227.88 | 2444.18 | 0.00 | 0.00 | 0.00 | 0.00 | 9.32 | 0.00 |
August | 13593.63 | 06-AUG-16:41 | 423.88 | 227.88 | 3028.56 | 0.00 | 0.00 | 0.00 | 0.00 | 50.67 | 0.00 |
September | 14794.60 | 04-SEP-16:51 | 423.88 | 227.88 | 3028.56 | 0.00 | 0.00 | 0.00 | 0.00 | 11.46 | 0.00 |
October | 6689.88 | 15-OCT-16:22 | 211.94 | 113.94 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.71 |
November | 3060.45 | 03-NOV-15:50 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.06 |
December | 1477.25 | 06-DEC-15:50 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.28 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1282.85 | 0.00 | 113.94 | 403.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 15124.15 | 805.38 | 410.20 | 3028.56 | 0.00 | 0.00 | 0.00 | 0.00 | 50.67 | 69.36 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1021.31 | 13-JAN-16:40 | 1272.23 | 1358.45 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.80 |
February | 1589.43 | 27-FEB-13:30 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.77 |
March | 1535.39 | 23-MAR-13:30 | 1306.65 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 116.60 |
April | 3592.07 | 07-APR-14:30 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.72 |
May | 4952.69 | 19-MAY-16:00 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 37.49 | 0.00 |
June | 8177.03 | 30-JUN-06:02 | 1339.19 | 1079.98 | 3189.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.25 |
July | 10512.99 | 16-JUL-18:21 | 0.00 | 359.98 | 3861.03 | 0.00 | 0.00 | 0.00 | 0.00 | 38.45 | 0.00 |
August | 9450.11 | 06-AUG-15:51 | 468.72 | 251.99 | 3348.91 | 0.00 | 0.00 | 0.00 | 0.00 | 133.23 | 0.00 |
September | 10325.43 | 04-SEP-16:11 | 669.60 | 359.98 | 4784.15 | 0.00 | 0.00 | 0.00 | 0.00 | 47.19 | 0.00 |
October | 3159.51 | 19-OCT-14:30 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.23 |
November | 1570.97 | 03-NOV-13:30 | 1306.65 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.83 |
December | 1152.37 | 06-DEC-16:20 | 1272.23 | 1358.45 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 111.43 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1021.31 | 0.00 | 251.99 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 10512.99 | 1339.19 | 1358.45 | 4784.15 | 0.00 | 0.00 | 0.00 | 0.00 | 133.23 | 116.60 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1324.76 | 20-JAN-10:00 | 1610.86 | 820.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 130.95 |
February | 3054.11 | 28-FEB-09:55 | 1610.86 | 820.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.62 |
March | 4889.82 | 23-MAR-10:10 | 805.43 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 112.99 |
April | 8504.22 | 16-APR-09:53 | 169.56 | 91.16 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 176.68 |
May | 8380.99 | 19-MAY-08:40 | 805.43 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.43 |
June | 13532.68 | 25-JUN-08:32 | 211.95 | 113.95 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.12 |
July | 17102.24 | 02-JUL-09:01 | 381.52 | 205.11 | 2725.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.76 |
August | 15506.10 | 06-AUG-08:32 | 254.35 | 136.74 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.12 |
September | 15750.73 | 04-SEP-08:51 | 296.74 | 159.53 | 2120.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.47 |
October | 5488.02 | 18-OCT-09:00 | 805.43 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.51 |
November | 2768.09 | 03-NOV-10:10 | 805.43 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.17 |
December | 1377.13 | 20-DEC-10:00 | 1610.86 | 820.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.31 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1324.76 | 169.56 | 91.16 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.12 | |
Maximum of Months | 17102.24 | 1610.86 | 820.45 | 2725.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 176.68 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 7012.99 | 19-JAN-13:30 | 1272.23 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 111.18 |
February | 17920.67 | 26-FEB-13:32 | 334.80 | 179.99 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 225.80 |
March | 12716.14 | 01-MAR-13:40 | 1272.23 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.40 |
April | 16539.93 | 16-APR-14:52 | 334.80 | 179.99 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 163.80 |
May | 10482.04 | 19-MAY-13:30 | 1306.65 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 16.14 | 0.00 |
June | 13843.00 | 25-JUN-13:53 | 267.84 | 143.99 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.65 |
July | 18753.13 | 16-JUL-12:22 | 401.76 | 215.99 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 3.92 | 0.00 |
August | 18356.50 | 06-AUG-13:12 | 401.76 | 215.99 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 99.67 | 0.00 |
September | 19595.26 | 04-SEP-14:51 | 535.68 | 287.98 | 3827.30 | 0.00 | 0.00 | 0.00 | 0.00 | 36.65 | 0.00 |
October | 18672.91 | 15-OCT-13:32 | 401.76 | 215.99 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 135.48 |
November | 12727.80 | 03-NOV-13:10 | 1306.65 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.31 |
December | 7495.17 | 12-DEC-12:30 | 687.71 | 647.98 | 1275.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.19 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 7012.99 | 267.84 | 143.99 | 1275.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 19595.26 | 1306.65 | 647.98 | 3827.30 | 0.00 | 0.00 | 0.00 | 0.00 | 99.67 | 225.80 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1640.29 | 13-JAN-15:50 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76.01 |
February | 4799.93 | 28-FEB-16:40 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.94 |
March | 5834.47 | 28-MAR-16:00 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 65.57 |
April | 15889.00 | 16-APR-17:32 | 0.00 | 136.73 | 1466.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69.65 |
May | 15632.05 | 28-MAY-17:02 | 0.00 | 136.73 | 1466.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 124.90 |
June | 16595.21 | 18-JUN-17:51 | 0.00 | 159.52 | 1710.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.15 |
July | 18089.20 | 16-JUL-17:01 | 0.00 | 227.88 | 2444.18 | 0.00 | 0.00 | 0.00 | 0.00 | 14.32 | 0.00 |
August | 15934.51 | 06-AUG-16:31 | 296.72 | 159.52 | 2119.99 | 0.00 | 0.00 | 0.00 | 0.00 | 76.40 | 0.00 |
September | 17632.15 | 04-SEP-16:11 | 423.88 | 227.88 | 3028.56 | 0.00 | 0.00 | 0.00 | 0.00 | 16.57 | 0.00 |
October | 11035.33 | 15-OCT-16:12 | 169.55 | 91.15 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.81 |
November | 3793.26 | 03-NOV-15:40 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.86 |
December | 1808.30 | 06-DEC-15:50 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.91 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1640.29 | 0.00 | 91.15 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 18089.20 | 805.38 | 410.20 | 3028.56 | 0.00 | 0.00 | 0.00 | 0.00 | 76.40 | 124.90 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
January | 0.107962E+12 | 95146.81 | 09-JAN-08:09 | 0.191148E+12 | 326022.83 | 09-JAN-07:19 |
February | 0.955439E+11 | 89618.92 | 27-FEB-15:30 | 0.102433E+12 | 287738.09 | 01-FEB-07:19 |
March | 0.108559E+12 | 84089.27 | 17-MAR-07:30 | 0.646021E+11 | 282380.50 | 06-MAR-07:19 |
April | 0.100537E+12 | 105442.91 | 06-APR-15:00 | 0.194747E+11 | 142521.03 | 29-APR-06:10 |
May | 0.110897E+12 | 136810.09 | 19-MAY-15:30 | 0.115770E+11 | 151617.56 | 08-MAY-06:10 |
June | 0.129118E+12 | 154400.15 | 29-JUN-15:09 | 0.764005E+09 | 35418.19 | 16-JUN-06:00 |
July | 0.145656E+12 | 185342.42 | 17-JUL-15:30 | 60365486.49 | 19554.39 | 05-JUL-06:19 |
August | 0.145582E+12 | 169661.25 | 07-AUG-15:39 | 0.351184E+09 | 26123.34 | 18-AUG-06:10 |
September | 0.116505E+12 | 166468.93 | 07-SEP-14:00 | 0.284729E+10 | 89128.44 | 19-SEP-06:10 |
October | 0.107221E+12 | 119318.71 | 18-OCT-15:00 | 0.125942E+11 | 166935.31 | 10-OCT-06:10 |
November | 0.103266E+12 | 94286.22 | 17-NOV-16:00 | 0.529004E+11 | 259656.32 | 27-NOV-07:19 |
December | 0.105163E+12 | 92073.21 | 29-DEC-08:09 | 0.129402E+12 | 306297.15 | 29-DEC-07:19 |
Annual Sum or Average | 0.137601E+13 | 0.588155E+12 | ||||
Minimum of Months | 0.955439E+11 | 84089.27 | 60365486.49 | 19554.39 | ||
Maximum of Months | 0.145656E+12 | 185342.42 | 0.191148E+12 | 326022.83 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [J] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [J] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.264207E+11 | 0.626771E+10 | 0.605851E+11 | 0.225896E+10 | 0.611156E+10 | 0.910798E+09 | 0.00 | 300716.96 | 0.00 | 0.00 | 0.00 | 0.540663E+10 | 0.00 |
February | 0.231055E+11 | 0.491554E+10 | 0.548702E+11 | 0.204970E+10 | 0.498255E+10 | 0.499739E+09 | 0.00 | 0.132266E+09 | 0.00 | 0.00 | 0.00 | 0.498838E+10 | 0.00 |
March | 0.270487E+11 | 0.447730E+10 | 0.627783E+11 | 0.235658E+10 | 0.575549E+10 | 0.314665E+09 | 0.00 | 396534.21 | 0.00 | 0.00 | 0.00 | 0.582710E+10 | 0.00 |
April | 0.238052E+11 | 0.347008E+10 | 0.586172E+11 | 0.219323E+10 | 0.583523E+10 | 99905408.40 | 0.00 | 0.144033E+10 | 0.00 | 0.00 | 0.00 | 0.507593E+10 | 0.00 |
May | 0.254764E+11 | 0.289027E+10 | 0.616817E+11 | 0.230706E+10 | 0.771686E+10 | 70471907.29 | 0.00 | 0.559972E+10 | 0.00 | 0.00 | 0.00 | 0.515458E+10 | 0.00 |
June | 0.252394E+11 | 0.253198E+10 | 0.604966E+11 | 0.226919E+10 | 0.139659E+11 | 17917655.04 | 0.00 | 0.197793E+11 | 0.00 | 0.00 | 0.00 | 0.481716E+10 | 0.00 |
July | 0.236562E+11 | 0.272636E+10 | 0.597911E+11 | 0.223004E+10 | 0.182435E+11 | 12624311.69 | 0.00 | 0.346534E+11 | 0.00 | 0.00 | 0.00 | 0.434266E+10 | 0.00 |
August | 0.265002E+11 | 0.326860E+10 | 0.627783E+11 | 0.235606E+10 | 0.171355E+11 | 15452572.66 | 0.00 | 0.288491E+11 | 0.00 | 0.00 | 0.00 | 0.467850E+10 | 0.00 |
September | 0.239586E+11 | 0.391803E+10 | 0.585950E+11 | 0.219216E+10 | 0.102986E+11 | 27613264.40 | 0.00 | 0.132331E+11 | 0.00 | 0.00 | 0.00 | 0.428208E+10 | 0.00 |
October | 0.252905E+11 | 0.500538E+10 | 0.605962E+11 | 0.225947E+10 | 0.665675E+10 | 71140991.66 | 0.00 | 0.272604E+10 | 0.00 | 0.00 | 0.00 | 0.461540E+10 | 0.00 |
November | 0.257040E+11 | 0.579766E+10 | 0.591197E+11 | 0.220159E+10 | 0.525616E+10 | 0.257800E+09 | 0.00 | 0.122773E+09 | 0.00 | 0.00 | 0.00 | 0.480616E+10 | 0.00 |
December | 0.255767E+11 | 0.653724E+10 | 0.597800E+11 | 0.223025E+10 | 0.536577E+10 | 0.627720E+09 | 0.00 | 291630.63 | 0.00 | 0.00 | 0.00 | 0.504485E+10 | 0.00 |
Annual Sum or Average | 0.301782E+12 | 0.518061E+11 | 0.719689E+12 | 0.269043E+11 | 0.107324E+12 | 0.292585E+10 | 0.00 | 0.106537E+12 | 0.00 | 0.00 | 0.00 | 0.590394E+11 | 0.00 |
Minimum of Months | 0.231055E+11 | 0.253198E+10 | 0.548702E+11 | 0.204970E+10 | 0.498255E+10 | 12624311.69 | 0.00 | 291630.63 | 0.00 | 0.00 | 0.00 | 0.428208E+10 | 0.00 |
Maximum of Months | 0.270487E+11 | 0.653724E+10 | 0.627783E+11 | 0.235658E+10 | 0.182435E+11 | 0.910798E+09 | 0.00 | 0.346534E+11 | 0.00 | 0.00 | 0.00 | 0.582710E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
January | 0.00 | 0.00 | 0.191148E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.102433E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.646021E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.194747E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.115770E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.764005E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 60365486.49 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.351184E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.284729E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.125942E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.529004E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.129402E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.588155E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 60365486.49 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.191148E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | EXTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY {Maximum} [W] | PUMPS:ELECTRICITY {TIMESTAMP} | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 32642.50 | 02-JAN-08:09 | 5686.19 | 01-JAN-06:10 | 41699.26 | 02-JAN-08:09 | 1410.29 | 04-JAN-12:09 | 9192.58 | 09-JAN-07:10 | 1064.89 | 09-JAN-09:39 | 0.00 | 01-JAN-00:10 |
February | 30631.47 | 02-FEB-08:09 | 5686.19 | 01-FEB-06:10 | 41699.26 | 01-FEB-08:09 | 1410.29 | 03-FEB-17:19 | 8858.99 | 06-FEB-07:10 | 988.86 | 01-FEB-07:19 | 0.00 | 01-FEB-00:10 |
March | 32642.50 | 17-MAR-07:10 | 5686.19 | 01-MAR-06:10 | 41699.26 | 01-MAR-08:09 | 1410.29 | 01-MAR-12:09 | 8418.11 | 06-MAR-07:10 | 959.90 | 06-MAR-07:10 | 0.00 | 01-MAR-00:10 |
April | 30143.87 | 14-APR-07:10 | 5686.19 | 01-APR-05:10 | 41699.26 | 03-APR-07:10 | 1410.29 | 04-APR-11:09 | 14386.74 | 25-APR-15:00 | 657.05 | 29-APR-06:10 | 0.00 | 01-APR-00:10 |
May | 28290.68 | 03-MAY-07:10 | 5686.19 | 01-MAY-05:10 | 41699.26 | 01-MAY-07:10 | 1410.29 | 04-MAY-16:10 | 22827.49 | 19-MAY-15:30 | 759.67 | 08-MAY-06:10 | 0.00 | 01-MAY-00:10 |
June | 26180.04 | 16-JUN-07:10 | 3328.83 | 01-JUN-20:10 | 41699.26 | 01-JUN-07:10 | 1410.29 | 01-JUN-11:09 | 29257.98 | 29-JUN-14:30 | 216.72 | 16-JUN-06:10 | 0.00 | 01-JUN-00:10 |
July | 26798.99 | 07-JUL-07:30 | 3328.83 | 01-JUL-20:30 | 41699.26 | 03-JUL-07:10 | 1410.29 | 05-JUL-07:19 | 36534.75 | 17-JUL-15:30 | 113.00 | 05-JUL-06:19 | 0.00 | 01-JUL-00:10 |
August | 27208.76 | 17-AUG-07:10 | 5686.19 | 03-AUG-05:10 | 41699.26 | 01-AUG-07:10 | 1410.29 | 16-AUG-16:10 | 34297.01 | 07-AUG-15:39 | 225.12 | 18-AUG-06:10 | 0.00 | 01-AUG-00:10 |
September | 29804.58 | 11-SEP-07:10 | 5686.19 | 01-SEP-05:10 | 41699.26 | 01-SEP-07:10 | 1410.29 | 11-SEP-11:09 | 31400.16 | 07-SEP-14:00 | 418.60 | 19-SEP-06:10 | 0.00 | 01-SEP-00:10 |
October | 32642.50 | 25-OCT-07:10 | 5686.19 | 01-OCT-05:10 | 41699.26 | 02-OCT-07:10 | 1410.29 | 04-OCT-16:10 | 16273.98 | 18-OCT-15:00 | 806.27 | 10-OCT-06:10 | 0.00 | 01-OCT-00:10 |
November | 32642.50 | 01-NOV-07:10 | 5686.19 | 01-NOV-05:10 | 41699.26 | 01-NOV-07:10 | 1410.29 | 01-NOV-16:10 | 8458.74 | 03-NOV-15:30 | 923.46 | 27-NOV-07:10 | 0.00 | 01-NOV-00:10 |
December | 32642.50 | 01-DEC-08:09 | 5686.19 | 01-DEC-06:10 | 41699.26 | 01-DEC-08:09 | 1410.29 | 05-DEC-08:09 | 8385.73 | 26-DEC-07:10 | 1043.05 | 29-DEC-07:40 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 26180.04 | 3328.83 | 41699.26 | 1410.29 | 8385.73 | 113.00 | 0.00 | |||||||
Maximum of Months | 32642.50 | 5686.19 | 41699.26 | 1410.29 | 36534.75 | 1064.89 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 184.16 | 30-JAN-06:40 | 0.00 | 0.00 | 0.00 | 7216.10 | 31-JAN-12:30 | 0.00 |
February | 9145.18 | 27-FEB-15:30 | 0.00 | 0.00 | 0.00 | 7227.29 | 17-FEB-12:50 | 0.00 |
March | 92.53 | 14-MAR-13:39 | 0.00 | 0.00 | 0.00 | 7223.16 | 01-MAR-12:00 | 0.00 |
April | 19034.93 | 06-APR-15:00 | 0.00 | 0.00 | 0.00 | 7160.64 | 03-APR-11:50 | 0.00 |
May | 40240.89 | 19-MAY-15:20 | 0.00 | 0.00 | 0.00 | 6727.53 | 01-MAY-11:20 | 0.00 |
June | 53063.11 | 29-JUN-14:00 | 0.00 | 0.00 | 0.00 | 6279.51 | 01-JUN-11:00 | 0.00 |
July | 75865.04 | 17-JUL-15:00 | 0.00 | 0.00 | 0.00 | 6054.01 | 05-JUL-11:39 | 0.00 |
August | 62450.92 | 07-AUG-15:30 | 0.00 | 0.00 | 0.00 | 5803.89 | 01-AUG-11:50 | 0.00 |
September | 63088.28 | 07-SEP-14:00 | 0.00 | 0.00 | 0.00 | 5885.61 | 29-SEP-11:00 | 0.00 |
October | 29835.51 | 18-OCT-15:20 | 0.00 | 0.00 | 0.00 | 6252.68 | 31-OCT-11:50 | 0.00 |
November | 4229.83 | 04-NOV-13:00 | 0.00 | 0.00 | 0.00 | 6694.70 | 30-NOV-12:00 | 0.00 |
December | 102.47 | 15-DEC-05:30 | 0.00 | 0.00 | 0.00 | 7137.68 | 29-DEC-12:00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 92.53 | 0.00 | 0.00 | 0.00 | 5803.89 | 0.00 | ||
Maximum of Months | 75865.04 | 0.00 | 0.00 | 0.00 | 7227.29 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 95146.81 | 09-JAN-08:09 | 32642.50 | 41699.26 | 5686.19 | 1410.29 | 8436.28 | 1029.83 | 0.00 | 0.00 | 0.00 |
February | 89618.92 | 27-FEB-15:30 | 25681.07 | 41659.26 | 0.00 | 1410.29 | 7473.85 | 6.85 | 0.00 | 9145.18 | 0.00 |
March | 84089.27 | 17-MAR-07:30 | 32642.50 | 41699.26 | 0.00 | 1410.29 | 3629.73 | 199.49 | 0.00 | 0.00 | 0.00 |
April | 105442.91 | 06-APR-15:00 | 25681.07 | 41670.51 | 0.00 | 1410.29 | 12229.77 | 6.85 | 0.00 | 19034.93 | 0.00 |
May | 136810.09 | 19-MAY-15:30 | 25681.07 | 41670.51 | 0.00 | 1410.29 | 22827.49 | 6.85 | 0.00 | 40205.01 | 0.00 |
June | 154400.15 | 29-JUN-15:09 | 25681.07 | 41670.51 | 0.00 | 1410.29 | 28548.73 | 6.85 | 0.00 | 52481.50 | 0.00 |
July | 185342.42 | 17-JUL-15:30 | 25681.07 | 41670.51 | 0.00 | 1410.29 | 36534.75 | 6.85 | 0.00 | 75439.44 | 0.00 |
August | 169661.25 | 07-AUG-15:39 | 25681.07 | 41670.51 | 0.00 | 1410.29 | 34297.01 | 6.85 | 0.00 | 62317.12 | 0.00 |
September | 166468.93 | 07-SEP-14:00 | 25681.07 | 41659.26 | 0.00 | 1410.29 | 31400.16 | 6.87 | 0.00 | 63088.28 | 0.00 |
October | 119318.71 | 18-OCT-15:00 | 26557.73 | 41670.51 | 0.00 | 1410.29 | 16273.98 | 6.85 | 0.00 | 28765.94 | 0.00 |
November | 94286.22 | 17-NOV-16:00 | 32642.50 | 41670.51 | 5686.19 | 1410.29 | 4032.87 | 6.85 | 0.00 | 3836.08 | 0.00 |
December | 92073.21 | 29-DEC-08:09 | 32642.50 | 41699.26 | 5686.19 | 1410.29 | 5628.93 | 970.17 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | ||||||||||
Minimum of Months | 84089.27 | 25681.07 | 41659.26 | 0.00 | 1410.29 | 3629.73 | 6.85 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 185342.42 | 32642.50 | 41699.26 | 5686.19 | 1410.29 | 36534.75 | 1029.83 | 0.00 | 75439.44 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | |
January | 0.00 | 0.00 | 326022.83 | 09-JAN-07:19 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 287738.09 | 01-FEB-07:19 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 282380.50 | 06-MAR-07:19 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 142521.03 | 29-APR-06:10 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 151617.56 | 08-MAY-06:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 35418.19 | 16-JUN-06:00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 19554.39 | 05-JUL-06:19 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 26123.34 | 18-AUG-06:10 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 89128.44 | 19-SEP-06:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 166935.31 | 10-OCT-06:10 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 259656.32 | 27-NOV-07:19 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 306297.15 | 29-DEC-07:19 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 19554.39 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 326022.83 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 26.20 | 0.00 | 26.20 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.31 | 0.00 | 27.31 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.33 | 26.75 | 0.00 | 26.75 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.31 | 0.00 | 27.31 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 2.50 | 19.47 | 2.33 | 19.57 | 0.00 | 19.57 | 0.00 | 19.57 |
February | 0.33 | 19.72 | 0.33 | 19.72 | 0.00 | 19.72 | 0.00 | 19.72 |
March | 0.17 | 19.18 | 0.17 | 19.18 | 0.00 | 19.18 | 0.00 | 19.18 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.17 | 19.17 | 0.17 | 19.17 | 0.00 | 19.17 | 0.00 | 19.17 |
Annual Sum or Average | 3.17 | 19.47 | 3.00 | 19.54 | 0.00 | 19.54 | 0.00 | 19.54 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2.50 | 19.72 | 2.33 | 19.72 | 0.00 | 19.72 | 0.00 | 19.72 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 7.33 | 18.94 | 6.33 | 19.12 | 0.00 | 19.12 | 0.00 | 19.12 |
February | 1.67 | 19.25 | 1.50 | 19.37 | 0.00 | 19.37 | 0.00 | 19.37 |
March | 1.50 | 19.09 | 1.17 | 19.34 | 0.00 | 19.34 | 0.00 | 19.34 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 1.00 | 19.06 | 0.83 | 19.23 | 0.00 | 19.23 | 0.00 | 19.23 |
December | 2.33 | 19.14 | 2.00 | 19.29 | 0.00 | 19.29 | 0.00 | 19.29 |
Annual Sum or Average | 13.83 | 19.04 | 11.83 | 19.21 | 0.00 | 19.21 | 0.00 | 19.21 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 7.33 | 19.25 | 6.33 | 19.37 | 0.00 | 19.37 | 0.00 | 19.37 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 70.00 | 16.83 | 40.17 | 17.38 | 0.00 | 17.38 | 0.00 | 17.38 |
February | 22.67 | 16.87 | 12.17 | 17.40 | 0.00 | 17.40 | 0.00 | 17.40 |
March | 11.17 | 16.20 | 4.67 | 16.74 | 0.00 | 16.74 | 0.00 | 16.74 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.33 | 17.12 | 0.00 | 17.12 | 0.00 | 17.12 | 0.00 | 17.12 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 27.48 | 0.83 | 27.46 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 27.55 | 1.17 | 27.56 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 27.47 | 2.00 | 27.47 |
October | 0.17 | 16.95 | 0.00 | 16.95 | 0.00 | 16.95 | 0.00 | 16.95 |
November | 9.00 | 16.43 | 4.33 | 16.85 | 0.00 | 16.85 | 0.00 | 16.85 |
December | 37.00 | 16.36 | 17.50 | 16.82 | 0.00 | 16.82 | 0.00 | 16.82 |
Annual Sum or Average | 150.33 | 16.65 | 78.83 | 17.18 | 5.50 | 17.42 | 4.00 | 17.59 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 70.00 | 17.12 | 40.17 | 17.40 | 2.17 | 27.55 | 2.00 | 27.56 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 46.33 | 16.11 | 21.00 | 16.69 | 0.00 | 16.69 | 0.00 | 16.69 |
February | 13.83 | 15.57 | 3.00 | 15.93 | 0.00 | 15.93 | 0.00 | 15.93 |
March | 8.00 | 15.37 | 1.67 | 15.72 | 0.00 | 15.72 | 0.00 | 15.72 |
April | 0.17 | 17.24 | 0.00 | 17.24 | 0.00 | 17.24 | 0.00 | 17.24 |
May | 0.33 | 17.09 | 0.00 | 17.09 | 0.00 | 17.09 | 0.00 | 17.09 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 4.67 | 28.01 | 4.67 | 28.01 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 10.17 | 28.10 | 9.67 | 28.12 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 | 28.34 | 3.17 | 28.40 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 27.93 | 5.17 | 27.93 |
October | 0.17 | 16.91 | 0.00 | 16.91 | 0.00 | 16.91 | 0.00 | 16.91 |
November | 6.33 | 15.92 | 1.83 | 16.38 | 0.00 | 16.38 | 0.00 | 16.38 |
December | 27.17 | 15.48 | 8.17 | 15.74 | 0.00 | 15.74 | 0.00 | 15.74 |
Annual Sum or Average | 102.33 | 15.81 | 35.67 | 16.27 | 23.67 | 18.00 | 22.67 | 19.24 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.72 | 0.00 | 15.72 |
Maximum of Months | 46.33 | 17.24 | 21.00 | 17.24 | 10.17 | 28.34 | 9.67 | 28.40 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 41.00 | 16.46 | 19.00 | 17.11 | 0.00 | 17.11 | 0.00 | 17.11 |
February | 10.50 | 15.78 | 2.33 | 16.18 | 1.17 | 17.18 | 1.17 | 18.02 |
March | 7.50 | 15.73 | 2.17 | 16.23 | 0.00 | 16.23 | 0.00 | 16.23 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.64 | 0.83 | 27.64 |
May | 0.17 | 17.05 | 0.00 | 17.05 | 0.83 | 25.76 | 0.83 | 26.55 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 2.83 | 27.63 | 2.83 | 27.63 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 7.50 | 27.95 | 6.67 | 27.97 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 28.18 | 3.50 | 28.20 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 7.17 | 28.22 | 6.33 | 28.25 |
October | 0.17 | 17.02 | 0.00 | 17.02 | 2.50 | 27.40 | 2.50 | 27.74 |
November | 5.00 | 16.15 | 1.17 | 16.69 | 0.00 | 16.69 | 0.00 | 16.69 |
December | 20.33 | 15.84 | 7.17 | 16.22 | 0.00 | 16.22 | 0.00 | 16.22 |
Annual Sum or Average | 84.67 | 16.15 | 31.83 | 16.70 | 26.83 | 18.82 | 24.67 | 20.17 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.22 | 0.00 | 16.22 |
Maximum of Months | 41.00 | 17.05 | 19.00 | 17.11 | 7.50 | 28.22 | 6.67 | 28.25 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 43.17 | 15.91 | 18.17 | 16.46 | 0.00 | 16.46 | 0.00 | 16.46 |
February | 12.83 | 15.21 | 2.83 | 15.34 | 0.00 | 15.34 | 0.00 | 15.34 |
March | 8.00 | 15.45 | 2.17 | 15.85 | 0.00 | 15.85 | 0.00 | 15.85 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 28.12 | 0.67 | 28.12 |
May | 0.17 | 16.95 | 0.00 | 16.95 | 3.17 | 27.68 | 1.33 | 27.83 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 4.83 | 28.21 | 1.83 | 28.25 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 9.00 | 28.64 | 4.50 | 28.63 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 28.37 | 2.17 | 28.38 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 28.39 | 2.67 | 28.46 |
October | 0.17 | 16.90 | 0.00 | 16.90 | 0.50 | 24.90 | 0.33 | 25.81 |
November | 6.50 | 15.55 | 1.83 | 15.79 | 0.00 | 15.79 | 0.00 | 15.79 |
December | 26.50 | 15.25 | 7.83 | 15.39 | 0.00 | 15.39 | 0.00 | 15.39 |
Annual Sum or Average | 97.33 | 15.58 | 32.83 | 15.95 | 26.50 | 18.06 | 13.50 | 18.88 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.34 | 0.00 | 15.34 |
Maximum of Months | 43.17 | 16.95 | 18.17 | 16.95 | 9.00 | 28.64 | 4.50 | 28.63 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 51.83 | 18.29 | 39.33 | 18.71 | 0.00 | 18.71 | 0.00 | 18.71 |
February | 5.67 | 19.00 | 4.17 | 19.37 | 0.00 | 19.37 | 0.00 | 19.37 |
March | 3.67 | 18.31 | 2.67 | 18.75 | 0.00 | 18.75 | 0.00 | 18.75 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.67 | 19.01 | 0.50 | 19.30 | 0.00 | 19.30 | 0.00 | 19.30 |
December | 7.00 | 17.88 | 4.83 | 18.33 | 0.00 | 18.33 | 0.00 | 18.33 |
Annual Sum or Average | 68.83 | 18.32 | 51.50 | 18.74 | 0.00 | 18.74 | 0.00 | 18.74 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 51.83 | 19.01 | 39.33 | 19.37 | 0.00 | 19.37 | 0.00 | 19.37 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 23.50 | 17.10 | 12.50 | 17.73 | 0.00 | 17.73 | 0.00 | 17.73 |
February | 1.00 | 16.97 | 0.00 | 16.97 | 0.00 | 16.97 | 0.00 | 16.97 |
March | 1.17 | 16.40 | 0.33 | 17.04 | 0.00 | 17.04 | 0.00 | 17.04 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 2.67 | 27.64 | 2.67 | 27.64 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 8.50 | 27.84 | 8.17 | 27.85 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 28.02 | 2.67 | 28.06 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 4.67 | 27.69 | 4.50 | 27.69 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.17 | 17.00 | 0.00 | 17.00 | 0.00 | 17.00 | 0.00 | 17.00 |
December | 3.33 | 15.24 | 1.00 | 15.18 | 0.00 | 15.18 | 0.00 | 15.18 |
Annual Sum or Average | 29.17 | 16.85 | 13.83 | 17.43 | 18.83 | 20.59 | 18.00 | 22.22 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 23.50 | 17.10 | 12.50 | 17.73 | 8.50 | 28.02 | 8.17 | 28.06 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 124.50 | 16.66 | 117.17 | 16.71 | 0.00 | 16.71 | 0.00 | 16.71 |
February | 60.00 | 17.40 | 59.50 | 17.40 | 1.17 | 17.50 | 1.17 | 17.60 |
March | 49.17 | 18.11 | 49.00 | 18.11 | 0.00 | 18.11 | 0.00 | 18.11 |
April | 28.17 | 18.84 | 28.17 | 18.84 | 0.00 | 18.84 | 0.00 | 18.84 |
May | 21.50 | 18.92 | 21.50 | 18.92 | 0.00 | 18.92 | 0.00 | 18.92 |
June | 1.00 | 19.41 | 1.00 | 19.41 | 0.00 | 19.41 | 0.00 | 19.41 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 7.00 | 26.82 | 6.67 | 26.80 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 26.64 | 4.67 | 26.59 |
September | 4.50 | 19.79 | 4.50 | 19.79 | 8.50 | 23.74 | 6.83 | 24.94 |
October | 12.17 | 19.04 | 12.17 | 19.04 | 3.17 | 20.06 | 3.17 | 20.87 |
November | 33.33 | 18.07 | 33.33 | 18.07 | 0.50 | 18.14 | 0.50 | 18.21 |
December | 71.17 | 17.26 | 69.67 | 17.28 | 0.00 | 17.28 | 0.00 | 17.28 |
Annual Sum or Average | 405.50 | 17.55 | 396.00 | 17.58 | 25.50 | 17.88 | 23.00 | 18.13 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.71 | 0.00 | 16.71 |
Maximum of Months | 124.50 | 19.79 | 117.17 | 19.79 | 8.50 | 26.82 | 6.83 | 26.80 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 22.33 | 17.01 | 12.00 | 17.60 | 0.00 | 17.60 | 0.00 | 17.60 |
February | 0.67 | 16.86 | 0.00 | 16.86 | 0.00 | 16.86 | 0.00 | 16.86 |
March | 1.83 | 17.88 | 1.00 | 18.67 | 0.00 | 18.67 | 0.00 | 18.67 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.45 | 0.00 | 27.45 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 27.78 | 0.83 | 27.72 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 27.85 | 1.00 | 27.85 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 7.17 | 28.15 | 3.67 | 28.10 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 28.22 | 1.17 | 28.21 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 3.50 | 28.06 | 2.00 | 28.11 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 27.72 | 0.33 | 27.72 |
November | 0.17 | 16.97 | 0.00 | 16.97 | 0.00 | 16.97 | 0.00 | 16.97 |
December | 3.50 | 15.21 | 1.17 | 15.14 | 0.00 | 15.14 | 0.00 | 15.14 |
Annual Sum or Average | 28.50 | 16.85 | 14.17 | 17.39 | 18.50 | 20.61 | 9.00 | 21.56 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.14 | 0.00 | 15.14 |
Maximum of Months | 22.33 | 17.88 | 12.00 | 18.67 | 7.17 | 28.22 | 3.67 | 28.21 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 38.83 | 17.27 | 23.83 | 17.79 | 0.00 | 17.79 | 0.00 | 17.79 |
February | 5.00 | 17.29 | 2.50 | 17.80 | 0.00 | 17.80 | 0.00 | 17.80 |
March | 4.33 | 17.33 | 2.17 | 17.99 | 0.00 | 17.99 | 0.00 | 17.99 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 27.47 | 0.00 | 27.47 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 27.34 | 0.50 | 27.35 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.50 | 27.37 | 1.33 | 27.37 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 1.83 | 19.26 | 1.50 | 19.51 | 0.00 | 19.51 | 0.00 | 19.51 |
December | 11.83 | 17.36 | 8.17 | 17.75 | 0.00 | 17.75 | 0.00 | 17.75 |
Annual Sum or Average | 61.83 | 17.35 | 38.17 | 17.85 | 2.50 | 18.09 | 1.83 | 18.25 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 38.83 | 19.26 | 23.83 | 19.51 | 1.50 | 27.47 | 1.33 | 27.47 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 24.17 | 16.34 | 9.83 | 16.92 | 0.00 | 16.92 | 0.00 | 16.92 |
February | 2.50 | 15.73 | 0.50 | 15.60 | 0.00 | 15.60 | 0.00 | 15.60 |
March | 2.17 | 15.83 | 0.33 | 16.28 | 0.00 | 16.28 | 0.00 | 16.28 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 27.57 | 0.50 | 27.57 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.34 | 0.17 | 27.34 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 4.83 | 28.10 | 4.83 | 28.10 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 9.33 | 28.16 | 9.17 | 28.17 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.50 | 28.26 | 3.17 | 28.30 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 5.83 | 27.83 | 5.83 | 27.83 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.83 | 16.60 | 0.17 | 17.07 | 0.00 | 17.07 | 0.00 | 17.07 |
December | 6.00 | 15.29 | 2.17 | 15.33 | 0.00 | 15.33 | 0.00 | 15.33 |
Annual Sum or Average | 35.67 | 16.09 | 13.00 | 16.54 | 24.17 | 20.37 | 23.67 | 22.26 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 24.17 | 16.60 | 9.83 | 17.07 | 9.33 | 28.26 | 9.17 | 28.30 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 20.50 | 16.94 | 10.17 | 17.53 | 0.50 | 17.69 | 0.50 | 17.84 |
February | 0.83 | 16.54 | 0.17 | 16.29 | 1.50 | 23.43 | 1.50 | 25.21 |
March | 1.50 | 17.21 | 0.67 | 17.97 | 0.50 | 19.76 | 0.50 | 20.99 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 27.65 | 1.17 | 27.65 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 27.53 | 1.17 | 27.53 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 2.50 | 27.56 | 2.50 | 27.56 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 7.50 | 27.81 | 7.00 | 27.82 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 27.99 | 3.67 | 28.02 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 7.33 | 28.17 | 6.50 | 28.21 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 28.17 | 3.00 | 28.17 |
November | 0.33 | 17.97 | 0.17 | 18.44 | 1.33 | 25.10 | 1.33 | 26.15 |
December | 5.17 | 15.66 | 2.00 | 15.88 | 0.00 | 15.88 | 0.00 | 15.88 |
Annual Sum or Average | 28.33 | 16.72 | 13.17 | 17.25 | 30.67 | 21.78 | 28.83 | 23.54 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.88 | 0.00 | 15.88 |
Maximum of Months | 20.50 | 17.97 | 10.17 | 18.44 | 7.50 | 28.17 | 7.00 | 28.21 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 24.00 | 16.19 | 9.83 | 16.70 | 0.00 | 16.70 | 0.00 | 16.70 |
February | 2.50 | 15.75 | 0.83 | 15.56 | 0.00 | 15.56 | 0.00 | 15.56 |
March | 2.50 | 16.43 | 0.67 | 17.13 | 0.00 | 17.13 | 0.00 | 17.13 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 28.13 | 0.50 | 28.20 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 3.33 | 28.16 | 1.33 | 28.17 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 4.50 | 28.15 | 1.50 | 28.18 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 8.67 | 28.53 | 4.50 | 28.52 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 | 28.25 | 2.17 | 28.22 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 28.33 | 2.33 | 28.38 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 27.82 | 0.50 | 27.82 |
November | 1.00 | 16.34 | 0.17 | 16.78 | 0.00 | 16.78 | 0.00 | 16.78 |
December | 6.33 | 15.20 | 2.33 | 15.16 | 0.00 | 15.16 | 0.00 | 15.16 |
Annual Sum or Average | 36.33 | 16.01 | 13.83 | 16.39 | 25.50 | 20.41 | 12.83 | 21.56 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.16 | 0.00 | 15.16 |
Maximum of Months | 24.00 | 16.43 | 9.83 | 17.13 | 8.67 | 28.53 | 4.50 | 28.52 |
Report: ComfortReportSimple55Monthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 22.65 | 83.33 | 22.43 | 83.33 | 22.27 |
February | 448.17 | 23.30 | 15.50 | 23.23 | 15.50 | 23.16 |
March | 489.67 | 23.78 | 2.00 | 23.77 | 2.00 | 23.76 |
April | 317.67 | 24.01 | 7.17 | 24.05 | 0.00 | 24.05 |
May | 186.50 | 24.04 | 83.17 | 24.59 | 0.00 | 24.59 |
June | 0.00 | 0.00 | 242.00 | 24.74 | 0.00 | 24.74 |
July | 0.33 | 27.12 | 370.17 | 24.65 | 0.33 | 24.65 |
August | 0.00 | 0.00 | 271.17 | 24.83 | 0.00 | 24.83 |
September | 19.33 | 24.00 | 200.67 | 24.84 | 0.00 | 24.84 |
October | 138.67 | 23.99 | 46.50 | 24.48 | 0.00 | 24.48 |
November | 386.33 | 23.88 | 5.67 | 23.91 | 0.00 | 23.91 |
December | 497.00 | 23.31 | 15.17 | 23.23 | 15.17 | 23.16 |
Annual Sum or Average | 2985.67 | 23.50 | 1342.50 | 23.83 | 116.33 | 23.76 |
Minimum of Months | 0.00 | 0.00 | 2.00 | 22.43 | 0.00 | 22.27 |
Maximum of Months | 502.00 | 27.12 | 370.17 | 24.84 | 83.33 | 24.84 |
Report: ComfortReportSimple55Monthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 21.07 | 291.33 | 20.90 | 291.33 | 20.82 |
February | 454.00 | 21.79 | 118.17 | 21.56 | 118.17 | 21.40 |
March | 514.00 | 22.50 | 50.50 | 22.33 | 50.50 | 22.18 |
April | 464.33 | 23.23 | 0.00 | 23.23 | 0.00 | 23.23 |
May | 340.17 | 23.40 | 45.83 | 23.61 | 2.00 | 23.59 |
June | 82.33 | 23.66 | 147.83 | 24.14 | 0.00 | 24.14 |
July | 21.50 | 23.82 | 291.67 | 24.42 | 0.00 | 24.42 |
August | 31.67 | 23.65 | 163.17 | 24.51 | 0.00 | 24.51 |
September | 181.33 | 23.59 | 136.17 | 24.04 | 1.50 | 24.04 |
October | 427.00 | 23.38 | 0.00 | 23.38 | 0.00 | 23.38 |
November | 489.00 | 22.57 | 45.33 | 22.43 | 45.33 | 22.31 |
December | 497.00 | 21.48 | 189.17 | 21.22 | 189.17 | 21.07 |
Annual Sum or Average | 4004.33 | 22.47 | 1479.17 | 22.53 | 698.00 | 22.32 |
Minimum of Months | 21.50 | 21.07 | 0.00 | 20.90 | 0.00 | 20.82 |
Maximum of Months | 514.00 | 23.82 | 291.67 | 24.51 | 291.33 | 24.51 |
Report: ComfortReportSimple55Monthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.45 | 429.67 | 20.37 | 429.67 | 20.34 |
February | 454.00 | 21.05 | 279.17 | 20.84 | 279.17 | 20.75 |
March | 514.00 | 21.65 | 159.00 | 21.36 | 159.00 | 21.17 |
April | 471.67 | 22.54 | 49.50 | 22.36 | 49.50 | 22.22 |
May | 371.50 | 22.95 | 50.33 | 22.92 | 27.00 | 22.79 |
June | 140.83 | 23.43 | 132.33 | 23.86 | 0.00 | 23.86 |
July | 48.17 | 23.53 | 253.17 | 24.24 | 0.00 | 24.24 |
August | 87.33 | 23.49 | 145.83 | 24.14 | 0.00 | 24.14 |
September | 258.33 | 23.10 | 110.33 | 23.52 | 3.00 | 23.53 |
October | 488.17 | 22.62 | 28.00 | 22.51 | 28.00 | 22.41 |
November | 489.00 | 21.54 | 189.17 | 21.25 | 189.17 | 21.08 |
December | 497.00 | 20.65 | 353.00 | 20.46 | 353.00 | 20.39 |
Annual Sum or Average | 4322.00 | 21.84 | 2179.50 | 21.76 | 1517.50 | 21.50 |
Minimum of Months | 48.17 | 20.45 | 28.00 | 20.37 | 0.00 | 20.34 |
Maximum of Months | 514.00 | 23.53 | 429.67 | 24.24 | 429.67 | 24.24 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 19.76 | 495.00 | 19.76 | 495.00 | 19.75 |
February | 454.00 | 20.28 | 415.50 | 20.22 | 415.50 | 20.20 |
March | 514.00 | 20.73 | 332.67 | 20.52 | 332.67 | 20.43 |
April | 473.33 | 21.66 | 147.33 | 21.33 | 147.33 | 21.13 |
May | 382.33 | 22.31 | 102.50 | 22.19 | 69.00 | 21.95 |
June | 154.50 | 23.08 | 176.83 | 23.73 | 0.83 | 23.72 |
July | 65.67 | 23.57 | 286.17 | 24.28 | 3.33 | 24.30 |
August | 143.50 | 23.22 | 164.00 | 23.86 | 3.83 | 23.88 |
September | 305.00 | 22.42 | 118.83 | 22.82 | 29.00 | 22.74 |
October | 496.50 | 21.64 | 138.17 | 21.35 | 138.17 | 21.16 |
November | 489.00 | 20.50 | 341.00 | 20.31 | 341.00 | 20.23 |
December | 497.00 | 19.90 | 474.83 | 19.88 | 474.83 | 19.87 |
Annual Sum or Average | 4476.83 | 21.11 | 3192.83 | 21.09 | 2450.50 | 20.84 |
Minimum of Months | 65.67 | 19.76 | 102.50 | 19.76 | 0.83 | 19.75 |
Maximum of Months | 514.00 | 23.57 | 495.00 | 24.28 | 495.00 | 24.30 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 19.94 | 480.83 | 19.92 | 480.83 | 19.91 |
February | 454.00 | 20.59 | 341.50 | 20.42 | 341.50 | 20.35 |
March | 502.17 | 21.01 | 270.33 | 20.73 | 270.33 | 20.59 |
April | 388.00 | 21.62 | 130.67 | 21.45 | 108.83 | 21.23 |
May | 296.67 | 22.04 | 138.50 | 22.24 | 57.50 | 21.99 |
June | 129.00 | 23.30 | 269.50 | 24.08 | 17.33 | 24.19 |
July | 78.00 | 24.74 | 378.50 | 24.58 | 31.83 | 24.74 |
August | 119.17 | 23.25 | 302.50 | 24.07 | 12.00 | 24.15 |
September | 260.33 | 22.51 | 180.00 | 23.21 | 37.83 | 23.23 |
October | 446.67 | 21.71 | 103.33 | 21.46 | 100.67 | 21.26 |
November | 487.83 | 20.68 | 303.00 | 20.48 | 303.00 | 20.39 |
December | 497.00 | 20.00 | 461.83 | 19.96 | 461.83 | 19.95 |
Annual Sum or Average | 4160.83 | 21.18 | 3360.50 | 21.40 | 2223.50 | 21.15 |
Minimum of Months | 78.00 | 19.94 | 103.33 | 19.92 | 12.00 | 19.91 |
Maximum of Months | 502.17 | 24.74 | 480.83 | 24.58 | 480.83 | 24.74 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 485.50 | 20.49 | 391.00 | 20.28 | 388.33 | 20.18 |
February | 396.83 | 21.05 | 270.83 | 20.85 | 251.67 | 20.68 |
March | 427.00 | 21.07 | 268.17 | 20.95 | 234.67 | 20.77 |
April | 369.50 | 21.62 | 166.67 | 21.61 | 120.67 | 21.38 |
May | 316.00 | 22.02 | 153.83 | 22.24 | 69.67 | 21.99 |
June | 179.17 | 22.89 | 210.67 | 23.71 | 10.50 | 23.77 |
July | 108.50 | 23.82 | 312.50 | 24.33 | 23.00 | 24.47 |
August | 143.67 | 23.16 | 275.50 | 23.98 | 12.33 | 24.06 |
September | 227.83 | 22.59 | 214.83 | 23.43 | 38.33 | 23.47 |
October | 350.17 | 21.89 | 172.83 | 22.08 | 91.17 | 21.88 |
November | 414.17 | 21.17 | 243.00 | 21.01 | 214.67 | 20.81 |
December | 465.50 | 20.50 | 344.83 | 20.24 | 344.83 | 20.14 |
Annual Sum or Average | 3883.83 | 21.47 | 3024.67 | 21.71 | 1799.83 | 21.44 |
Minimum of Months | 108.50 | 20.49 | 153.83 | 20.24 | 10.50 | 20.14 |
Maximum of Months | 485.50 | 23.82 | 391.00 | 24.33 | 388.33 | 24.47 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 19.92 | 476.50 | 19.89 | 476.50 | 19.88 |
February | 444.00 | 20.47 | 355.83 | 20.33 | 355.00 | 20.27 |
March | 487.33 | 20.76 | 304.17 | 20.57 | 300.50 | 20.47 |
April | 415.67 | 21.41 | 165.00 | 21.31 | 138.17 | 21.13 |
May | 339.67 | 22.02 | 159.33 | 22.24 | 74.67 | 22.06 |
June | 200.33 | 22.75 | 228.83 | 23.62 | 10.50 | 23.68 |
July | 128.67 | 23.50 | 306.83 | 24.19 | 20.33 | 24.32 |
August | 174.67 | 22.84 | 242.00 | 23.75 | 9.33 | 23.80 |
September | 298.83 | 22.16 | 166.50 | 22.81 | 41.33 | 22.79 |
October | 442.33 | 21.40 | 145.00 | 21.24 | 129.00 | 21.07 |
November | 481.00 | 20.67 | 304.17 | 20.45 | 304.17 | 20.35 |
December | 497.00 | 20.03 | 445.17 | 19.95 | 445.17 | 19.92 |
Annual Sum or Average | 4411.50 | 21.11 | 3299.33 | 21.27 | 2304.67 | 21.03 |
Minimum of Months | 128.67 | 19.92 | 145.00 | 19.89 | 9.33 | 19.88 |
Maximum of Months | 502.00 | 23.50 | 476.50 | 24.19 | 476.50 | 24.32 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.02 | 500.33 | 20.02 | 500.33 | 20.02 |
February | 454.00 | 20.46 | 422.00 | 20.42 | 422.00 | 20.41 |
March | 514.00 | 20.75 | 367.83 | 20.63 | 367.83 | 20.58 |
April | 485.00 | 21.41 | 151.50 | 21.21 | 151.50 | 21.09 |
May | 447.17 | 22.37 | 68.00 | 22.26 | 52.67 | 22.11 |
June | 213.00 | 23.41 | 109.83 | 23.69 | 0.00 | 23.69 |
July | 52.50 | 23.71 | 241.67 | 24.26 | 0.00 | 24.26 |
August | 133.17 | 23.50 | 119.33 | 23.94 | 0.00 | 23.94 |
September | 290.67 | 22.91 | 92.83 | 23.31 | 3.17 | 23.32 |
October | 501.17 | 22.39 | 22.33 | 22.32 | 22.33 | 22.25 |
November | 489.00 | 21.12 | 245.67 | 20.90 | 245.67 | 20.79 |
December | 497.00 | 20.29 | 459.17 | 20.25 | 459.17 | 20.24 |
Annual Sum or Average | 4578.67 | 21.41 | 2800.50 | 21.32 | 2224.67 | 21.08 |
Minimum of Months | 52.50 | 20.02 | 22.33 | 20.02 | 0.00 | 20.02 |
Maximum of Months | 514.00 | 23.71 | 500.33 | 24.26 | 500.33 | 24.26 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.23 | 483.67 | 20.21 | 483.67 | 20.20 |
February | 454.00 | 20.86 | 318.17 | 20.67 | 318.17 | 20.60 |
March | 510.83 | 21.24 | 248.33 | 20.98 | 248.33 | 20.85 |
April | 426.50 | 21.98 | 83.00 | 21.80 | 76.17 | 21.63 |
May | 332.17 | 22.50 | 83.17 | 22.68 | 27.83 | 22.54 |
June | 102.83 | 23.41 | 265.17 | 24.21 | 6.00 | 24.25 |
July | 38.67 | 25.68 | 411.83 | 24.68 | 24.00 | 24.80 |
August | 61.17 | 23.81 | 330.33 | 24.37 | 9.00 | 24.43 |
September | 195.67 | 23.18 | 179.50 | 23.91 | 15.33 | 24.01 |
October | 407.50 | 22.61 | 14.83 | 22.61 | 9.33 | 22.56 |
November | 487.00 | 21.46 | 192.17 | 21.20 | 192.17 | 21.06 |
December | 497.00 | 20.42 | 421.50 | 20.35 | 421.50 | 20.33 |
Annual Sum or Average | 4015.33 | 21.55 | 3031.67 | 21.78 | 1831.50 | 21.53 |
Minimum of Months | 38.67 | 20.23 | 14.83 | 20.21 | 6.00 | 20.20 |
Maximum of Months | 510.83 | 25.68 | 483.67 | 24.68 | 483.67 | 24.80 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 493.50 | 19.73 | 393.33 | 19.49 | 388.50 | 19.37 |
February | 409.67 | 20.60 | 268.00 | 20.42 | 248.17 | 20.23 |
March | 464.83 | 20.94 | 210.50 | 20.64 | 205.17 | 20.46 |
April | 425.67 | 21.63 | 118.50 | 21.44 | 104.67 | 21.22 |
May | 377.00 | 21.85 | 112.83 | 21.91 | 65.17 | 21.69 |
June | 204.50 | 22.61 | 166.83 | 23.42 | 0.83 | 23.41 |
July | 67.33 | 23.43 | 326.83 | 24.35 | 9.67 | 24.42 |
August | 98.83 | 22.92 | 294.50 | 24.14 | 7.00 | 24.19 |
September | 187.17 | 22.90 | 227.17 | 23.91 | 26.17 | 24.03 |
October | 303.33 | 22.45 | 110.00 | 22.89 | 20.33 | 22.84 |
November | 403.83 | 21.51 | 152.83 | 21.35 | 123.67 | 21.09 |
December | 478.67 | 20.37 | 310.83 | 20.06 | 308.67 | 19.91 |
Annual Sum or Average | 3914.33 | 21.29 | 2692.17 | 21.55 | 1508.00 | 21.22 |
Minimum of Months | 67.33 | 19.73 | 110.00 | 19.49 | 0.83 | 19.37 |
Maximum of Months | 493.50 | 23.43 | 393.33 | 24.35 | 388.50 | 24.42 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.20 | 483.00 | 20.18 | 483.00 | 20.17 |
February | 450.17 | 20.74 | 348.00 | 20.59 | 348.00 | 20.53 |
March | 504.33 | 21.01 | 281.67 | 20.81 | 281.67 | 20.72 |
April | 452.33 | 21.75 | 106.83 | 21.60 | 97.67 | 21.46 |
May | 346.83 | 22.39 | 98.33 | 22.61 | 36.83 | 22.47 |
June | 157.33 | 23.19 | 205.83 | 23.90 | 4.33 | 23.93 |
July | 47.83 | 24.37 | 364.00 | 24.48 | 12.67 | 24.55 |
August | 96.67 | 23.35 | 259.50 | 24.19 | 4.83 | 24.22 |
September | 233.33 | 22.93 | 169.33 | 23.67 | 11.33 | 23.74 |
October | 426.17 | 22.39 | 25.83 | 22.40 | 13.50 | 22.35 |
November | 482.33 | 21.36 | 199.00 | 21.12 | 199.00 | 20.98 |
December | 497.00 | 20.41 | 419.17 | 20.33 | 419.17 | 20.30 |
Annual Sum or Average | 4196.33 | 21.47 | 2960.50 | 21.64 | 1912.00 | 21.39 |
Minimum of Months | 47.83 | 20.20 | 25.83 | 20.18 | 4.33 | 20.17 |
Maximum of Months | 504.33 | 24.37 | 483.00 | 24.48 | 483.00 | 24.55 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.05 | 487.67 | 20.04 | 487.67 | 20.03 |
February | 454.00 | 20.61 | 353.00 | 20.49 | 353.00 | 20.44 |
March | 514.00 | 21.14 | 242.67 | 20.89 | 242.67 | 20.76 |
April | 474.67 | 22.19 | 61.00 | 21.99 | 61.00 | 21.84 |
May | 359.00 | 22.71 | 74.17 | 22.77 | 31.83 | 22.61 |
June | 110.33 | 23.46 | 187.83 | 24.01 | 0.00 | 24.01 |
July | 25.67 | 23.79 | 317.00 | 24.43 | 0.67 | 24.43 |
August | 91.83 | 23.48 | 175.00 | 24.15 | 0.50 | 24.15 |
September | 263.50 | 22.88 | 109.17 | 23.39 | 5.83 | 23.40 |
October | 489.17 | 22.30 | 41.33 | 22.17 | 41.33 | 22.05 |
November | 489.00 | 21.05 | 259.50 | 20.80 | 259.50 | 20.67 |
December | 497.00 | 20.20 | 440.17 | 20.14 | 440.17 | 20.12 |
Annual Sum or Average | 4270.17 | 21.45 | 2748.50 | 21.47 | 1924.17 | 21.20 |
Minimum of Months | 25.67 | 20.05 | 41.33 | 20.04 | 0.00 | 20.03 |
Maximum of Months | 514.00 | 23.79 | 487.67 | 24.43 | 487.67 | 24.43 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 427.00 | 20.07 | 401.33 | 20.03 | 401.33 | 20.02 |
February | 379.83 | 20.77 | 259.83 | 20.59 | 258.50 | 20.50 |
March | 420.00 | 21.19 | 183.83 | 20.93 | 183.83 | 20.78 |
April | 334.17 | 21.95 | 72.17 | 21.93 | 48.67 | 21.77 |
May | 252.00 | 22.31 | 100.17 | 22.66 | 28.00 | 22.50 |
June | 109.83 | 23.72 | 223.33 | 24.31 | 17.33 | 24.44 |
July | 54.67 | 25.37 | 323.83 | 24.79 | 30.00 | 24.96 |
August | 91.33 | 23.60 | 238.83 | 24.29 | 11.83 | 24.39 |
September | 214.50 | 22.84 | 140.83 | 23.62 | 18.00 | 23.74 |
October | 379.33 | 22.13 | 37.67 | 22.06 | 31.17 | 21.95 |
November | 415.00 | 21.09 | 196.83 | 20.85 | 196.83 | 20.72 |
December | 422.00 | 20.18 | 366.67 | 20.11 | 366.67 | 20.08 |
Annual Sum or Average | 3499.67 | 21.44 | 2545.33 | 21.67 | 1592.17 | 21.42 |
Minimum of Months | 54.67 | 20.07 | 37.67 | 20.03 | 11.83 | 20.02 |
Maximum of Months | 427.00 | 25.37 | 401.33 | 24.79 | 401.33 | 24.96 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 478.33 | 20.82 | 352.33 | 20.59 | 346.33 | 20.47 |
February | 381.33 | 21.39 | 237.83 | 21.28 | 207.33 | 21.09 |
March | 415.50 | 21.51 | 197.83 | 21.43 | 157.00 | 21.22 |
April | 352.00 | 22.11 | 98.00 | 22.24 | 51.00 | 22.08 |
May | 289.50 | 22.44 | 130.00 | 22.79 | 36.83 | 22.62 |
June | 142.67 | 23.28 | 218.17 | 23.98 | 5.50 | 24.03 |
July | 64.83 | 24.45 | 347.33 | 24.52 | 20.00 | 24.64 |
August | 105.17 | 23.66 | 291.83 | 24.27 | 12.00 | 24.35 |
September | 192.17 | 23.16 | 228.50 | 23.97 | 23.00 | 24.11 |
October | 312.83 | 22.49 | 125.50 | 22.89 | 30.33 | 22.86 |
November | 392.67 | 21.71 | 186.00 | 21.63 | 144.67 | 21.40 |
December | 449.50 | 20.86 | 302.17 | 20.63 | 295.33 | 20.49 |
Annual Sum or Average | 3576.50 | 21.84 | 2715.50 | 22.17 | 1329.33 | 21.91 |
Minimum of Months | 64.83 | 20.82 | 98.00 | 20.59 | 5.50 | 20.47 |
Maximum of Months | 478.33 | 24.45 | 352.33 | 24.52 | 346.33 | 24.64 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.20 | 465.17 | 20.15 | 465.17 | 20.13 |
February | 438.83 | 20.75 | 311.83 | 20.59 | 309.50 | 20.52 |
March | 483.83 | 21.09 | 223.83 | 20.89 | 218.33 | 20.76 |
April | 411.33 | 21.88 | 92.67 | 21.87 | 66.33 | 21.75 |
May | 306.00 | 22.34 | 135.17 | 22.73 | 40.00 | 22.62 |
June | 157.33 | 23.12 | 237.83 | 23.88 | 7.33 | 23.94 |
July | 75.33 | 24.14 | 343.67 | 24.44 | 20.17 | 24.56 |
August | 129.50 | 23.22 | 256.83 | 24.05 | 8.00 | 24.11 |
September | 264.00 | 22.60 | 162.33 | 23.37 | 16.17 | 23.44 |
October | 428.17 | 21.96 | 61.83 | 21.95 | 42.00 | 21.85 |
November | 474.17 | 21.12 | 223.83 | 20.86 | 223.83 | 20.73 |
December | 497.00 | 20.32 | 405.00 | 20.21 | 405.00 | 20.17 |
Annual Sum or Average | 4167.50 | 21.41 | 2920.00 | 21.62 | 1821.83 | 21.38 |
Minimum of Months | 75.33 | 20.20 | 61.83 | 20.15 | 7.33 | 20.13 |
Maximum of Months | 502.00 | 24.14 | 465.17 | 24.44 | 465.17 | 24.56 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.65168 | 16.56358 | -0.2281 | 7.23372 |
February | 454.00000 | 23.31774 | 16.03812 | -0.0547 | 5.99823 |
March | 514.00000 | 23.83102 | 16.95922 | 0.09773 | 5.66600 |
April | 485.00000 | 24.20762 | 19.88435 | 0.23396 | 6.29816 |
May | 508.00000 | 24.39366 | 22.87998 | -0.5547 | 12.43701 |
June | 496.00000 | 24.38581 | 30.76702 | -0.4315 | 9.40752 |
July | 497.00000 | 24.49675 | 34.58240 | -0.3504 | 8.29887 |
August | 514.00000 | 24.44691 | 30.58158 | -0.3979 | 8.92239 |
September | 485.00000 | 24.43966 | 30.07224 | -0.4353 | 9.71839 |
October | 502.00000 | 24.35434 | 22.00162 | 0.30529 | 7.14486 |
November | 489.00000 | 24.04182 | 18.16213 | 0.16250 | 5.95708 |
December | 497.00000 | 23.31080 | 15.69879 | -0.0586 | 6.00951 |
Annual Sum or Average | 5943.00000 | 23.99398 | 22.89424 | -0.1443 | 7.77656 |
Minimum of Months | 454.00000 | 22.65168 | 15.69879 | -0.5547 | 5.66600 |
Maximum of Months | 514.00000 | 24.49675 | 34.58240 | 0.30529 | 12.43701 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 21.06908 | 17.28702 | -0.5979 | 13.56929 |
February | 454.00000 | 21.79005 | 17.49359 | -0.4005 | 9.77692 |
March | 514.00000 | 22.50047 | 18.84658 | -0.2075 | 7.33729 |
April | 485.00000 | 23.28126 | 21.91594 | 0.01900 | 5.80866 |
May | 508.00000 | 23.75975 | 24.51684 | -0.7772 | 19.48770 |
June | 496.00000 | 24.11667 | 31.80864 | -0.5421 | 11.63355 |
July | 497.00000 | 24.28733 | 35.50058 | -0.4415 | 9.51973 |
August | 514.00000 | 24.23420 | 31.51933 | -0.4944 | 10.51888 |
September | 485.00000 | 24.05797 | 31.55066 | -0.5913 | 13.37985 |
October | 502.00000 | 23.51455 | 24.25832 | 0.09483 | 5.72649 |
November | 489.00000 | 22.57313 | 20.43149 | -0.1828 | 7.03060 |
December | 497.00000 | 21.48484 | 17.43026 | -0.4781 | 11.36352 |
Annual Sum or Average | 5943.00000 | 23.06472 | 24.42310 | -0.3841 | 10.44870 |
Minimum of Months | 454.00000 | 21.06908 | 17.28702 | -0.7772 | 5.72649 |
Maximum of Months | 514.00000 | 24.28733 | 35.50058 | 0.09483 | 19.48770 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.44567 | 15.90506 | -0.7919 | 19.98646 |
February | 454.00000 | 21.05103 | 18.10488 | -0.6008 | 14.30795 |
March | 514.00000 | 21.65393 | 19.52970 | -0.4217 | 10.76029 |
April | 485.00000 | 22.58126 | 22.72572 | -0.1514 | 7.07351 |
May | 508.00000 | 23.32087 | 24.97023 | -0.9299 | 25.84258 |
June | 496.00000 | 23.95825 | 31.91876 | -0.5964 | 13.34335 |
July | 497.00000 | 24.17976 | 35.45098 | -0.4745 | 10.24985 |
August | 514.00000 | 24.10644 | 31.59203 | -0.5424 | 11.80091 |
September | 485.00000 | 23.65887 | 32.25495 | -0.7355 | 18.55795 |
October | 502.00000 | 22.66185 | 25.52850 | -0.1160 | 6.59905 |
November | 489.00000 | 21.53665 | 21.39135 | -0.4456 | 11.13553 |
December | 497.00000 | 20.64550 | 17.82358 | -0.7108 | 17.89243 |
Annual Sum or Average | 5943.00000 | 22.49441 | 24.80496 | -0.5434 | 13.97405 |
Minimum of Months | 454.00000 | 20.44567 | 15.90506 | -0.9299 | 6.59905 |
Maximum of Months | 514.00000 | 24.17976 | 35.45098 | -0.1160 | 25.84258 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 19.76411 | 16.22228 | -1.0464 | 30.30075 |
February | 454.00000 | 20.27682 | 19.11325 | -0.8474 | 22.17446 |
March | 514.00000 | 20.72753 | 20.89248 | -0.6725 | 16.86903 |
April | 485.00000 | 21.71572 | 24.48716 | -0.3624 | 10.43195 |
May | 508.00000 | 22.79918 | 26.50514 | -1.0948 | 33.75159 |
June | 496.00000 | 23.84527 | 32.38923 | -0.6093 | 14.72423 |
July | 497.00000 | 24.20590 | 35.42420 | -0.4339 | 10.23959 |
August | 514.00000 | 23.94186 | 32.23521 | -0.5815 | 13.89625 |
September | 485.00000 | 23.13236 | 33.88463 | -0.9132 | 27.13280 |
October | 502.00000 | 21.66282 | 27.56169 | -0.3612 | 9.91387 |
November | 489.00000 | 20.49596 | 23.00442 | -0.7275 | 18.68248 |
December | 497.00000 | 19.90346 | 18.80676 | -0.9644 | 27.03358 |
Annual Sum or Average | 5943.00000 | 21.88583 | 25.91394 | -0.7174 | 19.58552 |
Minimum of Months | 454.00000 | 19.76411 | 16.22228 | -1.0948 | 9.91387 |
Maximum of Months | 514.00000 | 24.20590 | 35.42420 | -0.3612 | 33.75159 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 19.93907 | 15.54737 | -0.9899 | 27.84865 |
February | 454.00000 | 20.58718 | 18.02387 | -0.7464 | 19.39321 |
March | 514.00000 | 21.08088 | 19.55956 | -0.5576 | 14.87103 |
April | 485.00000 | 22.13469 | 22.91315 | -0.2178 | 9.88585 |
May | 508.00000 | 22.94270 | 25.37791 | -0.9643 | 29.33538 |
June | 496.00000 | 23.98302 | 31.62603 | -0.4458 | 12.78824 |
July | 497.00000 | 24.34119 | 34.81877 | -0.2493 | 9.05823 |
August | 514.00000 | 24.01546 | 31.46135 | -0.4265 | 11.93294 |
September | 485.00000 | 23.33208 | 32.81637 | -0.7616 | 23.27028 |
October | 502.00000 | 21.97430 | 26.18891 | -0.2532 | 9.03646 |
November | 489.00000 | 20.69227 | 21.89290 | -0.6616 | 16.56903 |
December | 497.00000 | 20.00254 | 18.01746 | -0.9265 | 25.46595 |
Annual Sum or Average | 5943.00000 | 22.09756 | 24.89176 | -0.5994 | 17.44656 |
Minimum of Months | 454.00000 | 19.93907 | 15.54737 | -0.9899 | 9.03646 |
Maximum of Months | 514.00000 | 24.34119 | 34.81877 | -0.2178 | 29.33538 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.62284 | 14.81875 | -0.7821 | 22.80529 |
February | 454.00000 | 21.47482 | 16.86934 | -0.4892 | 16.25541 |
March | 514.00000 | 21.59631 | 18.59632 | -0.4089 | 13.88417 |
April | 485.00000 | 22.27326 | 22.50485 | -0.1872 | 10.36803 |
May | 508.00000 | 22.88745 | 25.30117 | -1.0033 | 31.54296 |
June | 496.00000 | 23.73524 | 32.12670 | -0.5861 | 16.05720 |
July | 497.00000 | 24.15340 | 35.19948 | -0.3722 | 10.87883 |
August | 514.00000 | 23.95219 | 31.46120 | -0.4599 | 13.09681 |
September | 485.00000 | 23.49575 | 32.15229 | -0.6652 | 21.77050 |
October | 502.00000 | 22.59952 | 24.69196 | -0.0671 | 9.73802 |
November | 489.00000 | 21.65698 | 20.39684 | -0.3956 | 13.63981 |
December | 497.00000 | 20.72272 | 17.07336 | -0.7081 | 20.75134 |
Annual Sum or Average | 5943.00000 | 22.43821 | 24.30975 | -0.5114 | 16.75086 |
Minimum of Months | 454.00000 | 20.62284 | 14.81875 | -1.0033 | 9.73802 |
Maximum of Months | 514.00000 | 24.15340 | 35.19948 | -0.0671 | 31.54296 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 19.92462 | 15.36448 | -1.0016 | 28.45542 |
February | 454.00000 | 20.55486 | 17.80868 | -0.7602 | 20.47521 |
March | 514.00000 | 20.93354 | 19.45540 | -0.6010 | 16.08953 |
April | 485.00000 | 21.81588 | 23.24430 | -0.2965 | 10.72652 |
May | 508.00000 | 22.75251 | 25.66011 | -1.0231 | 32.78962 |
June | 496.00000 | 23.60896 | 32.56501 | -0.5882 | 16.82413 |
July | 497.00000 | 24.03538 | 35.68536 | -0.3844 | 11.74604 |
August | 514.00000 | 23.76055 | 32.15981 | -0.5359 | 15.00392 |
September | 485.00000 | 22.97965 | 33.35064 | -0.8755 | 27.98958 |
October | 502.00000 | 21.72439 | 26.28330 | -0.3104 | 10.07609 |
November | 489.00000 | 20.72026 | 21.62476 | -0.6573 | 17.19172 |
December | 497.00000 | 20.02531 | 17.77694 | -0.9262 | 25.74018 |
Annual Sum or Average | 5943.00000 | 21.91435 | 25.12266 | -0.6631 | 19.42406 |
Minimum of Months | 454.00000 | 19.92462 | 15.36448 | -1.0231 | 10.07609 |
Maximum of Months | 514.00000 | 24.03538 | 35.68536 | -0.2965 | 32.78962 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.02172 | 16.44905 | -0.9601 | 26.17485 |
February | 454.00000 | 20.46061 | 19.20071 | -0.7935 | 19.52186 |
March | 514.00000 | 20.74684 | 21.14004 | -0.6680 | 15.55004 |
April | 485.00000 | 21.41325 | 25.04277 | -0.4437 | 10.13498 |
May | 508.00000 | 22.60307 | 27.24070 | -1.1839 | 36.87698 |
June | 496.00000 | 23.82305 | 33.01296 | -0.6594 | 15.19219 |
July | 497.00000 | 24.18783 | 35.81232 | -0.4744 | 10.25373 |
August | 514.00000 | 24.02143 | 32.43903 | -0.5800 | 12.83165 |
September | 485.00000 | 23.47011 | 33.30816 | -0.8030 | 21.21257 |
October | 502.00000 | 22.39414 | 26.43907 | -0.1727 | 6.68978 |
November | 489.00000 | 21.12060 | 22.36963 | -0.5425 | 12.63849 |
December | 497.00000 | 20.28936 | 18.79579 | -0.8282 | 21.04373 |
Annual Sum or Average | 5943.00000 | 22.05838 | 25.97652 | -0.6758 | 17.35767 |
Minimum of Months | 454.00000 | 20.02172 | 16.44905 | -1.1839 | 6.68978 |
Maximum of Months | 514.00000 | 24.18783 | 35.81232 | -0.1727 | 36.87698 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.22522 | 15.97556 | -0.8967 | 23.63099 |
February | 454.00000 | 20.86174 | 18.36970 | -0.6707 | 16.58578 |
March | 514.00000 | 21.25558 | 20.05061 | -0.5129 | 12.74257 |
April | 485.00000 | 22.25409 | 23.24328 | -0.2078 | 8.41103 |
May | 508.00000 | 23.12073 | 25.67418 | -0.9422 | 27.49182 |
June | 496.00000 | 24.13055 | 31.65911 | -0.4390 | 11.28570 |
July | 497.00000 | 24.48538 | 34.69016 | -0.2324 | 7.79795 |
August | 514.00000 | 24.24967 | 31.21430 | -0.3699 | 9.40724 |
September | 485.00000 | 23.86822 | 31.91210 | -0.5892 | 15.65379 |
October | 502.00000 | 22.89912 | 24.98655 | -0.0218 | 6.52425 |
November | 489.00000 | 21.46845 | 21.43675 | -0.4422 | 10.86070 |
December | 497.00000 | 20.42180 | 18.25007 | -0.7820 | 19.45132 |
Annual Sum or Average | 5943.00000 | 22.44821 | 24.82629 | -0.5086 | 14.15811 |
Minimum of Months | 454.00000 | 20.22522 | 15.97556 | -0.9422 | 6.52425 |
Maximum of Months | 514.00000 | 24.48538 | 34.69016 | -0.0218 | 27.49182 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 19.82751 | 13.94721 | -0.8875 | 26.20993 |
February | 454.00000 | 21.01792 | 16.15754 | -0.5373 | 16.87725 |
March | 514.00000 | 21.25646 | 18.03825 | -0.4462 | 12.89210 |
April | 485.00000 | 21.98369 | 22.21830 | -0.2513 | 9.39204 |
May | 508.00000 | 22.51799 | 25.41919 | -1.1278 | 35.83608 |
June | 496.00000 | 23.58757 | 32.41589 | -0.6649 | 17.28664 |
July | 497.00000 | 24.22399 | 34.92721 | -0.3819 | 9.94892 |
August | 514.00000 | 24.07230 | 31.04027 | -0.4327 | 11.46455 |
September | 485.00000 | 23.82914 | 31.19828 | -0.5340 | 16.22465 |
October | 502.00000 | 23.20998 | 23.06517 | 0.11548 | 8.07284 |
November | 489.00000 | 22.05228 | 19.00299 | -0.2377 | 10.60006 |
December | 497.00000 | 20.52960 | 16.05526 | -0.6726 | 19.09721 |
Annual Sum or Average | 5943.00000 | 22.35064 | 23.67005 | -0.5060 | 16.18945 |
Minimum of Months | 454.00000 | 19.82751 | 13.94721 | -1.1278 | 8.07284 |
Maximum of Months | 514.00000 | 24.22399 | 34.92721 | 0.11548 | 35.83608 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.19884 | 15.82500 | -0.9119 | 24.20963 |
February | 454.00000 | 20.76943 | 18.21133 | -0.6950 | 17.37443 |
March | 514.00000 | 21.06443 | 20.00262 | -0.5642 | 13.75698 |
April | 485.00000 | 21.92301 | 23.58802 | -0.2887 | 8.82861 |
May | 508.00000 | 23.03454 | 25.77465 | -0.9676 | 29.12199 |
June | 496.00000 | 23.90305 | 32.37938 | -0.5400 | 13.37651 |
July | 497.00000 | 24.32231 | 35.27951 | -0.3267 | 8.73463 |
August | 514.00000 | 24.11673 | 31.74279 | -0.4470 | 10.97015 |
September | 485.00000 | 23.67010 | 32.26000 | -0.6591 | 17.99919 |
October | 502.00000 | 22.65960 | 25.14077 | -0.0754 | 6.73913 |
November | 489.00000 | 21.39893 | 21.27262 | -0.4558 | 11.27182 |
December | 497.00000 | 20.41435 | 18.04480 | -0.7871 | 19.88150 |
Annual Sum or Average | 5943.00000 | 22.30114 | 24.99990 | -0.5597 | 15.19575 |
Minimum of Months | 454.00000 | 20.19884 | 15.82500 | -0.9676 | 6.73913 |
Maximum of Months | 514.00000 | 24.32231 | 35.27951 | -0.0754 | 29.12199 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.05193 | 16.25890 | -0.9316 | 25.23128 |
February | 454.00000 | 20.60602 | 18.95772 | -0.7270 | 17.78380 |
March | 514.00000 | 21.14298 | 20.63338 | -0.5382 | 13.02811 |
April | 485.00000 | 22.22911 | 23.93812 | -0.2242 | 7.82073 |
May | 508.00000 | 23.19008 | 26.06485 | -0.9535 | 27.55697 |
June | 496.00000 | 24.02714 | 32.16396 | -0.5479 | 12.24097 |
July | 497.00000 | 24.31818 | 35.39444 | -0.3992 | 9.12993 |
August | 514.00000 | 24.11451 | 32.01497 | -0.5219 | 11.63898 |
September | 485.00000 | 23.55480 | 33.13930 | -0.7630 | 20.48550 |
October | 502.00000 | 22.34601 | 26.59612 | -0.1814 | 7.19501 |
November | 489.00000 | 21.05469 | 22.35777 | -0.5565 | 13.60563 |
December | 497.00000 | 20.20492 | 18.70604 | -0.8396 | 21.94492 |
Annual Sum or Average | 5943.00000 | 22.24940 | 25.55595 | -0.5984 | 15.63639 |
Minimum of Months | 454.00000 | 20.05193 | 16.25890 | -0.9535 | 7.19501 |
Maximum of Months | 514.00000 | 24.31818 | 35.39444 | -0.1814 | 27.55697 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 427.00000 | 20.06990 | 14.88294 | -0.9174 | 24.73063 |
February | 385.00000 | 20.82296 | 17.26803 | -0.6594 | 16.66315 |
March | 433.00000 | 21.28116 | 18.79529 | -0.4851 | 12.56647 |
April | 410.00000 | 22.39213 | 22.21877 | -0.1461 | 8.31644 |
May | 430.00000 | 23.14933 | 24.85514 | -0.8970 | 26.54735 |
June | 418.00000 | 24.12917 | 31.27473 | -0.4191 | 11.73772 |
July | 422.00000 | 24.49345 | 34.51805 | -0.2322 | 8.76333 |
August | 433.00000 | 24.16375 | 31.01433 | -0.4062 | 10.98143 |
September | 410.00000 | 23.58419 | 32.08732 | -0.6800 | 20.03259 |
October | 427.00000 | 22.36730 | 25.06139 | -0.1467 | 7.44612 |
November | 417.00000 | 21.10475 | 20.64221 | -0.5332 | 12.94941 |
December | 422.00000 | 20.18043 | 17.19608 | -0.8390 | 21.86295 |
Annual Sum or Average | 5034.00000 | 22.31997 | 24.18140 | -0.5300 | 15.22051 |
Minimum of Months | 385.00000 | 20.06990 | 14.88294 | -0.9174 | 7.44612 |
Maximum of Months | 433.00000 | 24.49345 | 34.51805 | -0.1461 | 26.54735 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 21.00283 | 14.65867 | -0.6503 | 18.67745 |
February | 454.00000 | 21.89732 | 16.53011 | -0.3542 | 13.28516 |
March | 514.00000 | 22.03615 | 18.27237 | -0.2728 | 10.91938 |
April | 485.00000 | 22.72007 | 22.00732 | -0.0635 | 8.29141 |
May | 508.00000 | 23.25398 | 24.90778 | -0.8703 | 25.74307 |
June | 496.00000 | 23.96394 | 31.86452 | -0.5134 | 12.87955 |
July | 497.00000 | 24.31647 | 35.06522 | -0.3257 | 9.18688 |
August | 514.00000 | 24.15375 | 31.23986 | -0.3954 | 10.58197 |
September | 485.00000 | 23.85887 | 31.53659 | -0.5337 | 16.33462 |
October | 502.00000 | 23.15333 | 23.86234 | 0.08446 | 8.38695 |
November | 489.00000 | 22.25584 | 19.69278 | -0.2210 | 10.61538 |
December | 497.00000 | 21.19701 | 16.71949 | -0.5527 | 16.40433 |
Annual Sum or Average | 5943.00000 | 22.82393 | 23.90796 | -0.3903 | 13.45930 |
Minimum of Months | 454.00000 | 21.00283 | 14.65867 | -0.8703 | 8.29141 |
Maximum of Months | 514.00000 | 24.31647 | 35.06522 | 0.08446 | 25.74307 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.19586 | 15.26608 | -0.8915 | 23.76909 |
February | 454.00000 | 20.87045 | 17.57225 | -0.6441 | 16.59471 |
March | 514.00000 | 21.26928 | 19.26594 | -0.4826 | 12.72115 |
April | 485.00000 | 22.24533 | 22.81789 | -0.1749 | 8.42313 |
May | 508.00000 | 23.11923 | 25.29211 | -0.8897 | 26.96383 |
June | 496.00000 | 23.85816 | 32.29743 | -0.5098 | 13.40999 |
July | 497.00000 | 24.22665 | 35.50849 | -0.3301 | 9.74017 |
August | 514.00000 | 23.99414 | 31.90291 | -0.4618 | 12.02397 |
September | 485.00000 | 23.38988 | 32.71043 | -0.7296 | 21.53604 |
October | 502.00000 | 22.28945 | 25.50889 | -0.1539 | 7.74271 |
November | 489.00000 | 21.20497 | 21.04944 | -0.5016 | 12.83271 |
December | 497.00000 | 20.32374 | 17.59821 | -0.8032 | 20.96509 |
Annual Sum or Average | 5943.00000 | 22.25985 | 24.77435 | -0.5476 | 15.56231 |
Minimum of Months | 454.00000 | 20.19586 | 15.26608 | -0.8915 | 7.74271 |
Maximum of Months | 514.00000 | 24.22665 | 35.50849 | -0.1539 | 26.96383 |
Report: BoilerReportMonthly
For: HEATSYS1 BOILER
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportBOILER HEATING ENERGY [J] | BOILER GAS CONSUMPTION [] | BOILER HEATING ENERGY {HOURS NON-ZERO} [HOURS] | BOILER HEATING RATE {Maximum} [W] | BOILER HEATING RATE {TIMESTAMP} | BOILER GAS CONSUMPTION RATE [] | BOILER INLET TEMPERATURE [C] | BOILER OUTLET TEMPERATURE [C] | BOILER MASS FLOW RATE [kg/s] | BOILER ANCILLARY ELECTRICITY RATE [W] | BOILER PART LOAD RATIO [] | BOILER PART LOAD RATIO {Maximum} [] | BOILER PART LOAD RATIO {TIMESTAMP} | |
January | 0.139929E+12 | 0.00 | 523.77 | 267299.89 | 17-JAN-06:11 | 0.00 | 35.74 | 51.60 | 0.66 | 0.00 | 0.13 | 0.64 | 17-JAN-06:11 |
February | 0.718547E+11 | 0.00 | 389.66 | 263014.02 | 13-FEB-06:11 | 0.00 | 31.20 | 46.45 | 0.33 | 0.00 | 0.07 | 0.63 | 13-FEB-06:11 |
March | 0.431061E+11 | 0.00 | 387.63 | 235261.91 | 01-MAR-07:01 | 0.00 | 28.66 | 43.76 | 0.16 | 0.00 | 0.04 | 0.56 | 01-MAR-07:01 |
April | 0.121377E+11 | 0.00 | 215.29 | 219495.76 | 28-APR-06:01 | 0.00 | 29.01 | 38.04 | 0.04 | 0.00 | 0.01 | 0.53 | 28-APR-06:01 |
May | 0.738148E+10 | 0.00 | 131.09 | 215952.49 | 01-MAY-06:01 | 0.00 | 38.41 | 43.02 | 0.03 | 0.00 | 0.01 | 0.52 | 01-MAY-06:01 |
June | 0.473070E+09 | 0.00 | 59.87 | 39143.91 | 17-JUN-06:03 | 0.00 | 38.67 | 40.75 | 0.00 | 0.00 | 0.00 | 0.09 | 17-JUN-06:03 |
July | 36302579.46 | 0.00 | 39.87 | 17514.41 | 05-JUL-06:06 | 0.00 | 36.81 | 38.06 | 0.00 | 0.00 | 0.00 | 0.04 | 05-JUL-06:06 |
August | 0.211637E+09 | 0.00 | 29.95 | 33496.09 | 18-AUG-06:03 | 0.00 | 40.14 | 40.91 | 0.00 | 0.00 | 0.00 | 0.08 | 18-AUG-06:03 |
September | 0.177303E+10 | 0.00 | 91.86 | 153188.86 | 19-SEP-06:03 | 0.00 | 37.45 | 40.65 | 0.01 | 0.00 | 0.00 | 0.37 | 19-SEP-06:03 |
October | 0.797578E+10 | 0.00 | 181.11 | 222372.98 | 05-OCT-06:01 | 0.00 | 28.13 | 35.58 | 0.03 | 0.00 | 0.01 | 0.53 | 05-OCT-06:01 |
November | 0.351592E+11 | 0.00 | 339.16 | 219843.12 | 22-NOV-06:11 | 0.00 | 29.14 | 42.71 | 0.13 | 0.00 | 0.03 | 0.53 | 22-NOV-06:11 |
December | 0.911900E+11 | 0.00 | 488.00 | 246447.08 | 29-DEC-07:11 | 0.00 | 33.65 | 50.10 | 0.39 | 0.00 | 0.08 | 0.59 | 29-DEC-07:11 |
Annual Sum or Average | 0.411228E+12 | 0.00 | 2877.25 | 0.00 | 33.94 | 42.63 | 0.15 | 0.00 | 0.03 | ||||
Minimum of Months | 36302579.46 | 0.00 | 29.95 | 17514.41 | 0.00 | 28.13 | 35.58 | 0.00 | 0.00 | 0.00 | 0.04 | ||
Maximum of Months | 0.139929E+12 | 0.00 | 523.77 | 267299.89 | 0.00 | 40.14 | 51.60 | 0.66 | 0.00 | 0.13 | 0.64 |
Report: DXReportMonthly
For: PACU_VAV_BOT COOLING COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 |
February | 0.185777E+09 | 46308631.22 | 8.33 | 0.185770E+09 | 7860.38 | 0.00 | 0.51 | 27-FEB-15:40 | 0.00 | 01-FEB-00:10 | 14469.84 | 27-FEB-15:40 | 14469.84 | 27-FEB-15:40 | 4.92 | 26-FEB-16:45 | 3477.07 | 27-FEB-15:40 | 0.00 |
March | 37611.29 | 10220.75 | 0.04 | 37611.29 | 0.00 | 0.00 | 0.01 | 23-MAR-06:03 | 0.00 | 01-MAR-00:10 | 250.74 | 23-MAR-06:03 | 250.74 | 23-MAR-06:03 | 0.00 | 23-MAR-06:03 | 68.14 | 23-MAR-06:03 | 0.00 |
April | 0.190249E+10 | 0.462090E+09 | 61.71 | 0.189322E+10 | 9268485.43 | 0.00 | 0.91 | 06-APR-16:00 | 0.00 | 01-APR-00:10 | 28445.41 | 06-APR-16:00 | 28445.41 | 06-APR-16:00 | 518.39 | 22-APR-15:00 | 6137.27 | 06-APR-16:00 | 0.00 |
May | 0.780736E+10 | 0.182647E+10 | 148.19 | 0.764472E+10 | 0.162642E+09 | 0.00 | 1.00 | 19-MAY-11:50 | 0.00 | 01-MAY-00:10 | 53935.87 | 19-MAY-15:30 | 53935.87 | 19-MAY-15:30 | 5260.90 | 02-MAY-13:00 | 12585.72 | 19-MAY-15:20 | 0.00 |
June | 0.286883E+11 | 0.661534E+10 | 309.86 | 0.274967E+11 | 0.119161E+10 | 0.00 | 1.00 | 05-JUN-12:10 | 0.00 | 01-JUN-00:10 | 67388.74 | 20-JUN-16:00 | 66522.55 | 29-JUN-14:50 | 13748.50 | 22-JUN-06:03 | 17429.64 | 29-JUN-15:00 | 0.00 |
July | 0.500020E+11 | 0.118840E+11 | 403.14 | 0.484322E+11 | 0.156984E+10 | 0.00 | 1.00 | 01-JUL-09:40 | 0.00 | 01-JUL-00:10 | 83646.60 | 17-JUL-16:00 | 83646.60 | 17-JUL-16:00 | 24110.24 | 19-JUL-06:03 | 25523.50 | 17-JUL-16:00 | 0.00 |
August | 0.425761E+11 | 0.100045E+11 | 368.77 | 0.421868E+11 | 0.389271E+09 | 0.00 | 1.00 | 01-AUG-10:20 | 0.00 | 01-AUG-00:10 | 76315.67 | 07-AUG-16:00 | 76315.67 | 07-AUG-16:00 | 6271.63 | 09-AUG-11:10 | 20003.83 | 07-AUG-16:00 | 0.00 |
September | 0.204001E+11 | 0.472665E+10 | 242.33 | 0.187518E+11 | 0.164828E+10 | 0.00 | 1.00 | 01-SEP-09:20 | 0.00 | 01-SEP-00:10 | 103868.84 | 07-SEP-14:55 | 65188.75 | 04-SEP-16:11 | 49999.13 | 07-SEP-14:50 | 22000.06 | 07-SEP-14:55 | 0.00 |
October | 0.446782E+10 | 0.102773E+10 | 96.46 | 0.445248E+10 | 15339445.30 | 0.00 | 1.00 | 16-OCT-14:10 | 0.00 | 01-OCT-00:10 | 49482.53 | 18-OCT-15:40 | 49482.53 | 18-OCT-15:40 | 692.36 | 15-OCT-11:05 | 10605.64 | 18-OCT-15:30 | 0.00 |
November | 0.164302E+09 | 43226350.25 | 15.33 | 0.160415E+09 | 3886612.57 | 0.00 | 0.23 | 17-NOV-17:00 | 0.00 | 01-NOV-00:10 | 6084.47 | 17-NOV-17:00 | 6084.47 | 17-NOV-17:00 | 343.97 | 17-NOV-18:05 | 1569.18 | 17-NOV-17:00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 |
Annual Sum or Average | 0.156194E+12 | 0.366364E+11 | 1654.15 | 0.151204E+12 | 0.499014E+10 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Maximum of Months | 0.500020E+11 | 0.118840E+11 | 403.14 | 0.484322E+11 | 0.164828E+10 | 0.00 | 1.00 | 0.00 | 103868.84 | 83646.60 | 49999.13 | 25523.50 | 0.00 |
Report: DXReportMonthly
For: PACU_VAV_MID COOLING COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 |
February | 0.181164E+09 | 45360885.12 | 10.07 | 0.181164E+09 | 0.00 | 0.00 | 0.48 | 27-FEB-13:30 | 0.00 | 01-FEB-00:10 | 12550.64 | 27-FEB-13:30 | 12550.64 | 27-FEB-13:30 | 0.00 | 27-FEB-13:50 | 3045.41 | 27-FEB-13:30 | 0.00 |
March | 1354643.00 | 367810.48 | 1.17 | 1354643.00 | -0.0 | 0.00 | 0.01 | 14-MAR-13:40 | 0.00 | 01-MAR-00:10 | 340.86 | 14-MAR-13:40 | 340.86 | 14-MAR-13:40 | 0.00 | 14-MAR-13:20 | 92.53 | 14-MAR-13:40 | 0.00 |
April | 0.202466E+10 | 0.489148E+09 | 66.93 | 0.201443E+10 | 10232889.20 | 0.00 | 0.98 | 06-APR-16:00 | 0.00 | 01-APR-00:10 | 29594.25 | 06-APR-16:00 | 29594.25 | 06-APR-16:00 | 615.52 | 23-APR-14:10 | 6254.15 | 06-APR-16:00 | 0.00 |
May | 0.785031E+10 | 0.183002E+10 | 154.28 | 0.768895E+10 | 0.161361E+09 | 0.00 | 1.00 | 18-MAY-15:00 | 0.00 | 01-MAY-00:10 | 54714.36 | 19-MAY-15:30 | 54714.36 | 19-MAY-15:30 | 5070.91 | 02-MAY-13:00 | 12773.57 | 19-MAY-15:20 | 0.00 |
June | 0.275249E+11 | 0.634511E+10 | 315.28 | 0.263806E+11 | 0.114431E+10 | 0.00 | 1.00 | 05-JUN-12:10 | 0.00 | 01-JUN-00:10 | 64017.44 | 20-JUN-16:00 | 63598.31 | 29-JUN-14:50 | 7981.22 | 20-JUN-15:00 | 16639.75 | 29-JUN-15:00 | 0.00 |
July | 0.460576E+11 | 0.109724E+11 | 401.55 | 0.447147E+11 | 0.134287E+10 | 0.00 | 1.00 | 01-JUL-09:50 | 0.00 | 01-JUL-00:10 | 79050.53 | 17-JUL-15:30 | 79050.53 | 17-JUL-15:30 | 13006.51 | 17-JUL-06:03 | 23711.88 | 17-JUL-15:30 | 0.00 |
August | 0.387182E+11 | 0.913513E+10 | 367.76 | 0.383495E+11 | 0.368750E+09 | 0.00 | 1.00 | 01-AUG-10:40 | 0.00 | 01-AUG-00:10 | 75379.54 | 07-AUG-15:30 | 75379.54 | 07-AUG-15:30 | 4164.82 | 22-AUG-15:30 | 19931.13 | 07-AUG-15:30 | 0.00 |
September | 0.180035E+11 | 0.418716E+10 | 231.61 | 0.166135E+11 | 0.138995E+10 | 0.00 | 1.00 | 01-SEP-09:20 | 0.00 | 01-SEP-00:10 | 98172.94 | 07-SEP-14:55 | 74977.51 | 04-SEP-16:11 | 46365.60 | 07-SEP-14:55 | 20793.63 | 07-SEP-14:55 | 0.00 |
October | 0.375756E+10 | 0.874317E+09 | 94.47 | 0.374328E+10 | 14277610.21 | 0.00 | 1.00 | 18-OCT-12:00 | 0.00 | 01-OCT-00:10 | 44382.65 | 18-OCT-15:50 | 44382.65 | 18-OCT-15:50 | 495.58 | 15-OCT-10:55 | 9496.71 | 18-OCT-15:20 | 0.00 |
November | 0.155966E+09 | 41163514.03 | 16.00 | 0.148513E+09 | 7452456.76 | 0.00 | 0.23 | 04-NOV-14:00 | 0.00 | 01-NOV-00:10 | 5579.05 | 04-NOV-14:00 | 5579.05 | 04-NOV-14:00 | 376.04 | 17-NOV-17:00 | 1441.12 | 04-NOV-14:00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 |
Annual Sum or Average | 0.144275E+12 | 0.339202E+11 | 1659.12 | 0.139836E+12 | 0.443920E+10 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | -0.0 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Maximum of Months | 0.460576E+11 | 0.109724E+11 | 401.55 | 0.447147E+11 | 0.138995E+10 | 0.00 | 1.00 | 0.00 | 98172.94 | 79050.53 | 46365.60 | 23711.88 | 0.00 |
Report: DXReportMonthly
For: PACU_VAV_TOP COOLING COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 1111996.74 | 300716.96 | 0.49 | 1102426.80 | 9569.94 | 0.00 | 0.05 | 30-JAN-06:40 | 0.00 | 01-JAN-00:10 | 1367.98 | 30-JAN-06:40 | 1367.98 | 30-JAN-06:40 | 31.90 | 01-JAN-10:20 | 368.31 | 30-JAN-06:40 | 0.00 |
February | 0.159223E+09 | 40596953.18 | 8.54 | 0.159222E+09 | 327.39 | 0.00 | 0.38 | 27-FEB-15:30 | 0.00 | 01-FEB-00:10 | 11252.70 | 27-FEB-15:30 | 11252.70 | 27-FEB-15:30 | 0.59 | 26-FEB-12:54 | 2796.91 | 27-FEB-15:30 | 0.00 |
March | 68128.95 | 18502.98 | 0.06 | 68128.95 | -0.0 | 0.00 | 0.01 | 08-MAR-05:43 | 0.00 | 01-MAR-00:10 | 340.64 | 08-MAR-05:43 | 340.64 | 08-MAR-05:43 | 0.00 | 01-MAR-00:10 | 92.51 | 08-MAR-05:43 | 0.00 |
April | 0.199734E+10 | 0.489088E+09 | 65.67 | 0.198239E+10 | 14941914.79 | 0.00 | 0.91 | 06-APR-16:00 | 0.00 | 01-APR-00:10 | 30786.32 | 06-APR-16:00 | 30786.32 | 06-APR-16:00 | 721.34 | 23-APR-13:45 | 6643.51 | 06-APR-16:00 | 0.00 |
May | 0.827110E+10 | 0.194323E+10 | 151.71 | 0.804353E+10 | 0.227570E+09 | 0.00 | 1.00 | 19-MAY-11:50 | 0.00 | 01-MAY-00:10 | 63690.30 | 19-MAY-15:30 | 63690.30 | 19-MAY-15:30 | 5544.50 | 02-MAY-13:00 | 14881.60 | 19-MAY-15:20 | 0.00 |
June | 0.293564E+11 | 0.681886E+10 | 313.27 | 0.280460E+11 | 0.131043E+10 | 0.00 | 1.00 | 05-JUN-12:50 | 0.00 | 01-JUN-00:10 | 72770.31 | 20-JUN-15:10 | 72508.40 | 29-JUN-14:50 | 8041.09 | 20-JUN-15:00 | 18993.72 | 29-JUN-15:00 | 0.00 |
July | 0.490847E+11 | 0.117969E+11 | 400.92 | 0.475405E+11 | 0.154423E+10 | 0.00 | 1.00 | 01-JUL-11:50 | 0.00 | 01-JUL-00:10 | 91285.91 | 17-JUL-15:20 | 91285.91 | 17-JUL-15:20 | 11773.04 | 19-JUL-09:30 | 27321.36 | 17-JUL-15:30 | 0.00 |
August | 0.407274E+11 | 0.970944E+10 | 365.62 | 0.402200E+11 | 0.507462E+09 | 0.00 | 1.00 | 01-AUG-11:40 | 0.00 | 01-AUG-00:10 | 87977.02 | 06-AUG-16:11 | 87977.02 | 06-AUG-16:11 | 4539.86 | 22-AUG-15:30 | 25392.74 | 06-AUG-16:11 | 0.00 |
September | 0.183481E+11 | 0.431925E+10 | 228.56 | 0.168109E+11 | 0.153715E+10 | 0.00 | 1.00 | 01-SEP-09:50 | 0.00 | 01-SEP-00:10 | 98544.56 | 07-SEP-15:20 | 81622.67 | 04-SEP-15:41 | 46975.03 | 07-SEP-15:00 | 21715.46 | 04-SEP-15:41 | 0.00 |
October | 0.346500E+10 | 0.823989E+09 | 90.94 | 0.343088E+10 | 34124820.57 | 0.00 | 1.00 | 18-OCT-12:40 | 0.00 | 01-OCT-00:10 | 45446.35 | 18-OCT-15:00 | 45446.35 | 18-OCT-15:00 | 734.46 | 15-OCT-11:15 | 9815.38 | 18-OCT-15:00 | 0.00 |
November | 0.144916E+09 | 38382713.51 | 15.16 | 0.134233E+09 | 10682520.59 | 0.00 | 0.19 | 04-NOV-14:00 | 0.00 | 01-NOV-00:10 | 5329.96 | 04-NOV-14:00 | 5329.96 | 04-NOV-14:00 | 519.69 | 17-NOV-17:00 | 1388.71 | 04-NOV-14:00 | 0.00 |
December | 1073522.51 | 291630.63 | 1.10 | 1072360.09 | 1162.43 | 0.00 | 0.02 | 18-DEC-06:05 | 0.00 | 01-DEC-00:10 | 664.54 | 18-DEC-06:05 | 664.54 | 18-DEC-06:05 | 3.87 | 03-DEC-09:00 | 179.99 | 18-DEC-06:05 | 0.00 |
Annual Sum or Average | 0.151556E+12 | 0.359804E+11 | 1642.04 | 0.146370E+12 | 0.518659E+10 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 68128.95 | 18502.98 | 0.06 | 68128.95 | -0.0 | 0.00 | 0.01 | 0.00 | 340.64 | 340.64 | 0.00 | 92.51 | 0.00 | ||||||
Maximum of Months | 0.490847E+11 | 0.117969E+11 | 400.92 | 0.475405E+11 | 0.154423E+10 | 0.00 | 1.00 | 0.00 | 98544.56 | 91285.91 | 46975.03 | 27321.36 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 339.38 | 0.00 | 339.38 | 15.07 | 2668.62 | 0.00 | 0.00 | 0.00 |
February | 479.19 | 0.00 | 479.19 | 97.54 | 1963.03 | 0.00 | 0.00 | 0.00 |
March | 778.42 | 0.00 | 778.42 | 304.16 | 1569.31 | 0.00 | 0.00 | 0.00 |
April | 887.57 | 5.18 | 882.39 | 500.47 | 1109.59 | 0.00 | 0.00 | 0.00 |
May | 1165.59 | 69.07 | 1096.52 | 891.48 | 841.35 | 0.00 | 0.00 | 0.00 |
June | 1357.26 | 156.01 | 1201.26 | 1392.59 | 554.43 | 0.00 | 0.00 | 0.00 |
July | 1239.93 | 116.13 | 1123.80 | 1502.01 | 467.26 | 0.00 | 0.00 | 0.00 |
August | 993.57 | 26.63 | 966.93 | 1097.62 | 527.67 | 0.00 | 0.00 | 0.00 |
September | 744.11 | 0.27 | 743.84 | 650.86 | 791.40 | 0.00 | 0.00 | 0.00 |
October | 542.79 | 0.00 | 542.79 | 273.44 | 1140.48 | 0.00 | 0.00 | 0.00 |
November | 368.99 | 0.00 | 368.99 | 73.10 | 1618.79 | 0.00 | 0.00 | 0.00 |
December | 284.59 | 0.00 | 284.59 | 8.29 | 2260.42 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 766.65 | 31.26 | 735.39 | 570.13 | 1290.19 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 284.59 | 0.00 | 284.59 | 8.29 | 467.26 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1357.26 | 156.01 | 1201.26 | 1502.01 | 2668.62 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 519.55 | 238.19 | 281.36 | 288.60 | 1637.37 | 0.00 | 0.00 | 0.00 |
February | 812.62 | 403.44 | 409.17 | 628.15 | 1205.13 | 0.00 | 0.00 | 0.00 |
March | 1092.64 | 452.10 | 640.53 | 915.70 | 988.29 | 0.00 | 0.00 | 0.00 |
April | 1394.10 | 690.90 | 703.19 | 1365.60 | 711.83 | 0.00 | 0.00 | 0.00 |
May | 1539.96 | 685.19 | 854.78 | 1606.08 | 566.07 | 0.00 | 0.00 | 0.00 |
June | 1993.28 | 1025.74 | 967.54 | 2372.51 | 379.39 | 0.00 | 0.00 | 0.00 |
July | 2092.00 | 1182.67 | 909.34 | 2680.14 | 312.47 | 0.00 | 0.00 | 0.00 |
August | 1818.05 | 1012.96 | 805.09 | 2277.32 | 349.30 | 0.00 | 0.00 | 0.00 |
September | 1286.09 | 663.87 | 622.21 | 1468.91 | 500.23 | 0.00 | 0.00 | 0.00 |
October | 922.70 | 468.53 | 454.17 | 892.47 | 718.27 | 0.00 | 0.00 | 0.00 |
November | 584.79 | 273.02 | 311.77 | 425.37 | 991.46 | 0.00 | 0.00 | 0.00 |
December | 431.32 | 185.25 | 246.07 | 228.87 | 1386.47 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1209.33 | 607.87 | 601.45 | 1266.10 | 810.79 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 431.32 | 185.25 | 246.07 | 228.87 | 312.47 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2092.00 | 1182.67 | 967.54 | 2680.14 | 1637.37 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 2392.28 | 1708.62 | 683.67 | 2251.73 | 2299.66 | 0.00 | 0.00 | 0.00 |
February | 3046.54 | 2191.18 | 855.35 | 3145.01 | 1726.09 | 0.00 | 0.00 | 0.00 |
March | 2723.21 | 1529.23 | 1193.98 | 2804.44 | 1536.35 | 0.00 | 0.00 | 0.00 |
April | 2189.00 | 1047.01 | 1141.99 | 2337.96 | 1146.32 | 0.00 | 0.00 | 0.00 |
May | 1944.87 | 645.95 | 1298.93 | 2107.95 | 914.39 | 0.00 | 0.00 | 0.00 |
June | 1932.43 | 563.59 | 1368.84 | 2377.29 | 637.45 | 0.00 | 0.00 | 0.00 |
July | 2083.35 | 769.58 | 1313.77 | 2854.64 | 511.47 | 0.00 | 0.00 | 0.00 |
August | 2475.92 | 1248.32 | 1227.61 | 3294.49 | 570.70 | 0.00 | 0.00 | 0.00 |
September | 2746.10 | 1682.62 | 1063.47 | 3392.98 | 805.80 | 0.00 | 0.00 | 0.00 |
October | 2870.90 | 1985.19 | 885.71 | 3271.92 | 1115.33 | 0.00 | 0.00 | 0.00 |
November | 2617.41 | 1895.95 | 721.46 | 2738.64 | 1434.66 | 0.00 | 0.00 | 0.00 |
December | 2274.93 | 1642.73 | 632.20 | 2198.87 | 1944.52 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 2437.21 | 1403.96 | 1033.24 | 2728.14 | 1218.42 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 1932.43 | 563.59 | 632.20 | 2107.95 | 511.47 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 3046.54 | 2191.18 | 1368.84 | 3392.98 | 2299.66 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 470.60 | 189.65 | 280.94 | 250.29 | 1706.15 | 0.00 | 0.00 | 0.00 |
February | 803.24 | 394.83 | 408.41 | 632.09 | 1237.46 | 0.00 | 0.00 | 0.00 |
March | 1027.95 | 376.66 | 651.30 | 843.58 | 1032.16 | 0.00 | 0.00 | 0.00 |
April | 1342.00 | 594.57 | 747.43 | 1328.98 | 754.26 | 0.00 | 0.00 | 0.00 |
May | 1659.96 | 757.03 | 902.93 | 1784.06 | 602.12 | 0.00 | 0.00 | 0.00 |
June | 1805.97 | 829.55 | 976.42 | 2158.19 | 419.27 | 0.00 | 0.00 | 0.00 |
July | 1850.01 | 934.84 | 915.17 | 2395.64 | 351.57 | 0.00 | 0.00 | 0.00 |
August | 1570.91 | 770.97 | 799.94 | 1982.44 | 378.01 | 0.00 | 0.00 | 0.00 |
September | 1263.70 | 638.88 | 624.82 | 1469.12 | 533.88 | 0.00 | 0.00 | 0.00 |
October | 903.20 | 448.75 | 454.45 | 895.29 | 755.42 | 0.00 | 0.00 | 0.00 |
November | 639.38 | 317.19 | 322.19 | 517.46 | 1031.46 | 0.00 | 0.00 | 0.00 |
December | 429.78 | 181.40 | 248.38 | 241.75 | 1429.56 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1148.79 | 536.71 | 612.08 | 1211.22 | 851.29 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 429.78 | 181.40 | 248.38 | 241.75 | 351.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1850.01 | 934.84 | 976.42 | 2395.64 | 1706.15 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 113.12 | 0.00 | 113.12 | 4.21 | 904.99 | 0.00 | 0.00 | 0.00 |
February | 159.72 | 0.00 | 159.72 | 32.59 | 665.80 | 0.00 | 0.00 | 0.00 |
March | 259.46 | 0.00 | 259.46 | 106.30 | 529.73 | 0.00 | 0.00 | 0.00 |
April | 295.84 | 1.73 | 294.12 | 178.25 | 366.36 | 0.00 | 0.00 | 0.00 |
May | 388.51 | 23.02 | 365.49 | 310.28 | 280.67 | 0.00 | 0.00 | 0.00 |
June | 452.40 | 52.00 | 400.40 | 474.21 | 183.38 | 0.00 | 0.00 | 0.00 |
July | 413.29 | 38.71 | 374.58 | 507.66 | 154.99 | 0.00 | 0.00 | 0.00 |
August | 331.17 | 8.88 | 322.30 | 370.09 | 178.17 | 0.00 | 0.00 | 0.00 |
September | 248.03 | 0.09 | 247.94 | 217.16 | 276.99 | 0.00 | 0.00 | 0.00 |
October | 180.92 | 0.00 | 180.92 | 85.08 | 412.15 | 0.00 | 0.00 | 0.00 |
November | 122.99 | 0.00 | 122.99 | 21.48 | 579.01 | 0.00 | 0.00 | 0.00 |
December | 94.86 | 0.00 | 94.86 | 2.58 | 786.42 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 255.54 | 10.42 | 245.12 | 193.47 | 442.40 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 94.86 | 0.00 | 94.86 | 2.58 | 154.99 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 452.40 | 52.00 | 400.40 | 507.66 | 904.99 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 113.13 | 0.00 | 113.13 | 4.21 | 905.05 | 0.00 | 0.00 | 0.00 |
February | 159.73 | 0.00 | 159.73 | 32.59 | 665.84 | 0.00 | 0.00 | 0.00 |
March | 259.47 | 0.00 | 259.47 | 106.30 | 529.76 | 0.00 | 0.00 | 0.00 |
April | 295.85 | 1.73 | 294.13 | 178.25 | 366.39 | 0.00 | 0.00 | 0.00 |
May | 388.53 | 23.02 | 365.50 | 310.29 | 280.69 | 0.00 | 0.00 | 0.00 |
June | 452.42 | 52.00 | 400.42 | 474.22 | 183.39 | 0.00 | 0.00 | 0.00 |
July | 413.31 | 38.71 | 374.60 | 507.68 | 155.00 | 0.00 | 0.00 | 0.00 |
August | 331.19 | 8.88 | 322.31 | 370.10 | 178.18 | 0.00 | 0.00 | 0.00 |
September | 248.04 | 0.09 | 247.95 | 217.17 | 277.01 | 0.00 | 0.00 | 0.00 |
October | 180.93 | 0.00 | 180.93 | 85.08 | 412.18 | 0.00 | 0.00 | 0.00 |
November | 123.00 | 0.00 | 123.00 | 21.48 | 579.05 | 0.00 | 0.00 | 0.00 |
December | 94.86 | 0.00 | 94.86 | 2.58 | 786.47 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 255.55 | 10.42 | 245.13 | 193.48 | 442.43 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 94.86 | 0.00 | 94.86 | 2.58 | 155.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 452.42 | 52.00 | 400.42 | 507.68 | 905.05 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 113.13 | 0.00 | 113.13 | 4.21 | 905.05 | 0.00 | 0.00 | 0.00 |
February | 159.73 | 0.00 | 159.73 | 32.59 | 665.84 | 0.00 | 0.00 | 0.00 |
March | 259.47 | 0.00 | 259.47 | 106.30 | 529.76 | 0.00 | 0.00 | 0.00 |
April | 295.85 | 1.73 | 294.13 | 178.25 | 366.39 | 0.00 | 0.00 | 0.00 |
May | 388.53 | 23.02 | 365.50 | 310.29 | 280.69 | 0.00 | 0.00 | 0.00 |
June | 452.42 | 52.00 | 400.42 | 474.22 | 183.39 | 0.00 | 0.00 | 0.00 |
July | 413.31 | 38.71 | 374.60 | 507.68 | 155.00 | 0.00 | 0.00 | 0.00 |
August | 331.19 | 8.88 | 322.31 | 370.10 | 178.18 | 0.00 | 0.00 | 0.00 |
September | 248.04 | 0.09 | 247.95 | 217.17 | 277.01 | 0.00 | 0.00 | 0.00 |
October | 180.93 | 0.00 | 180.93 | 85.08 | 412.18 | 0.00 | 0.00 | 0.00 |
November | 123.00 | 0.00 | 123.00 | 21.48 | 579.05 | 0.00 | 0.00 | 0.00 |
December | 94.86 | 0.00 | 94.86 | 2.58 | 786.47 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 255.55 | 10.42 | 245.13 | 193.48 | 442.43 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 94.86 | 0.00 | 94.86 | 2.58 | 155.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 452.42 | 52.00 | 400.42 | 507.68 | 905.05 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 499.78 | 229.13 | 270.65 | 276.23 | 1610.98 | 0.00 | 0.00 | 0.00 |
February | 781.70 | 388.09 | 393.60 | 605.28 | 1190.66 | 0.00 | 0.00 | 0.00 |
March | 1051.06 | 434.90 | 616.16 | 889.65 | 979.05 | 0.00 | 0.00 | 0.00 |
April | 1341.05 | 664.61 | 676.44 | 1329.17 | 701.36 | 0.00 | 0.00 | 0.00 |
May | 1481.37 | 659.11 | 822.25 | 1560.22 | 562.22 | 0.00 | 0.00 | 0.00 |
June | 1917.44 | 986.71 | 930.73 | 2295.80 | 376.65 | 0.00 | 0.00 | 0.00 |
July | 2012.40 | 1137.66 | 874.74 | 2587.38 | 315.66 | 0.00 | 0.00 | 0.00 |
August | 1748.87 | 974.41 | 774.46 | 2196.78 | 356.02 | 0.00 | 0.00 | 0.00 |
September | 1237.15 | 638.61 | 598.54 | 1410.24 | 521.72 | 0.00 | 0.00 | 0.00 |
October | 887.59 | 450.70 | 436.89 | 842.33 | 763.66 | 0.00 | 0.00 | 0.00 |
November | 562.54 | 262.63 | 299.91 | 395.00 | 1032.90 | 0.00 | 0.00 | 0.00 |
December | 414.90 | 178.20 | 236.70 | 215.33 | 1396.61 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1163.31 | 584.74 | 578.57 | 1220.44 | 815.97 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 414.90 | 178.20 | 236.70 | 215.33 | 315.66 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2012.40 | 1137.66 | 930.73 | 2587.38 | 1610.98 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 19.76 | 9.06 | 10.70 | 10.92 | 63.70 | 0.00 | 0.00 | 0.00 |
February | 30.91 | 15.34 | 15.56 | 23.93 | 47.08 | 0.00 | 0.00 | 0.00 |
March | 41.56 | 17.20 | 24.36 | 35.18 | 38.71 | 0.00 | 0.00 | 0.00 |
April | 53.02 | 26.28 | 26.75 | 52.55 | 27.73 | 0.00 | 0.00 | 0.00 |
May | 58.57 | 26.06 | 32.51 | 61.69 | 22.23 | 0.00 | 0.00 | 0.00 |
June | 75.81 | 39.01 | 36.80 | 90.77 | 14.89 | 0.00 | 0.00 | 0.00 |
July | 79.57 | 44.98 | 34.59 | 102.30 | 12.48 | 0.00 | 0.00 | 0.00 |
August | 69.15 | 38.53 | 30.62 | 86.86 | 14.08 | 0.00 | 0.00 | 0.00 |
September | 48.92 | 25.25 | 23.67 | 55.76 | 20.63 | 0.00 | 0.00 | 0.00 |
October | 35.09 | 17.82 | 17.27 | 33.31 | 30.19 | 0.00 | 0.00 | 0.00 |
November | 22.24 | 10.38 | 11.86 | 15.62 | 40.84 | 0.00 | 0.00 | 0.00 |
December | 16.40 | 7.05 | 9.36 | 8.51 | 55.22 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 46.00 | 23.12 | 22.88 | 48.25 | 32.26 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 16.40 | 7.05 | 9.36 | 8.51 | 12.48 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 79.57 | 44.98 | 36.80 | 102.30 | 63.70 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 797.41 | 569.53 | 227.89 | 760.59 | 778.73 | 0.00 | 0.00 | 0.00 |
February | 1015.49 | 730.38 | 285.11 | 1060.95 | 598.38 | 0.00 | 0.00 | 0.00 |
March | 907.72 | 509.73 | 397.99 | 948.06 | 531.66 | 0.00 | 0.00 | 0.00 |
April | 729.66 | 349.00 | 380.66 | 792.92 | 389.90 | 0.00 | 0.00 | 0.00 |
May | 648.28 | 215.31 | 432.97 | 717.95 | 308.71 | 0.00 | 0.00 | 0.00 |
June | 644.13 | 187.86 | 456.28 | 805.06 | 213.58 | 0.00 | 0.00 | 0.00 |
July | 694.44 | 256.52 | 437.92 | 958.74 | 175.95 | 0.00 | 0.00 | 0.00 |
August | 825.30 | 416.10 | 409.20 | 1104.23 | 201.04 | 0.00 | 0.00 | 0.00 |
September | 915.35 | 560.86 | 354.49 | 1134.72 | 294.28 | 0.00 | 0.00 | 0.00 |
October | 956.95 | 661.72 | 295.23 | 1089.44 | 417.58 | 0.00 | 0.00 | 0.00 |
November | 872.45 | 631.97 | 240.48 | 910.05 | 524.99 | 0.00 | 0.00 | 0.00 |
December | 758.29 | 547.56 | 210.73 | 734.92 | 678.64 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 812.39 | 467.98 | 344.41 | 917.04 | 425.48 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 644.13 | 187.86 | 210.73 | 717.95 | 175.95 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1015.49 | 730.38 | 456.28 | 1134.72 | 778.73 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 797.41 | 569.53 | 227.89 | 760.59 | 778.73 | 0.00 | 0.00 | 0.00 |
February | 1015.49 | 730.38 | 285.11 | 1060.95 | 598.38 | 0.00 | 0.00 | 0.00 |
March | 907.72 | 509.73 | 397.99 | 948.06 | 531.66 | 0.00 | 0.00 | 0.00 |
April | 729.66 | 349.00 | 380.66 | 792.92 | 389.90 | 0.00 | 0.00 | 0.00 |
May | 648.28 | 215.31 | 432.97 | 717.95 | 308.71 | 0.00 | 0.00 | 0.00 |
June | 644.13 | 187.86 | 456.28 | 805.06 | 213.58 | 0.00 | 0.00 | 0.00 |
July | 694.44 | 256.52 | 437.92 | 958.74 | 175.95 | 0.00 | 0.00 | 0.00 |
August | 825.30 | 416.10 | 409.20 | 1104.23 | 201.04 | 0.00 | 0.00 | 0.00 |
September | 915.35 | 560.86 | 354.49 | 1134.72 | 294.28 | 0.00 | 0.00 | 0.00 |
October | 956.95 | 661.72 | 295.23 | 1089.44 | 417.58 | 0.00 | 0.00 | 0.00 |
November | 872.45 | 631.97 | 240.48 | 910.05 | 524.99 | 0.00 | 0.00 | 0.00 |
December | 758.29 | 547.56 | 210.73 | 734.92 | 678.64 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 812.39 | 467.98 | 344.41 | 917.04 | 425.48 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 644.13 | 187.86 | 210.73 | 717.95 | 175.95 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1015.49 | 730.38 | 456.28 | 1134.72 | 778.73 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 797.36 | 569.49 | 227.87 | 760.54 | 778.68 | 0.00 | 0.00 | 0.00 |
February | 1015.43 | 730.33 | 285.10 | 1060.88 | 598.35 | 0.00 | 0.00 | 0.00 |
March | 907.66 | 509.70 | 397.96 | 948.00 | 531.63 | 0.00 | 0.00 | 0.00 |
April | 729.61 | 348.98 | 380.63 | 792.87 | 389.87 | 0.00 | 0.00 | 0.00 |
May | 648.24 | 215.30 | 432.94 | 717.90 | 308.69 | 0.00 | 0.00 | 0.00 |
June | 644.09 | 187.85 | 456.25 | 805.01 | 213.57 | 0.00 | 0.00 | 0.00 |
July | 694.40 | 256.51 | 437.89 | 958.68 | 175.94 | 0.00 | 0.00 | 0.00 |
August | 825.24 | 416.07 | 409.17 | 1104.16 | 201.03 | 0.00 | 0.00 | 0.00 |
September | 915.29 | 560.83 | 354.47 | 1134.65 | 294.26 | 0.00 | 0.00 | 0.00 |
October | 956.89 | 661.67 | 295.21 | 1089.37 | 417.55 | 0.00 | 0.00 | 0.00 |
November | 872.40 | 631.93 | 240.47 | 910.00 | 524.96 | 0.00 | 0.00 | 0.00 |
December | 758.25 | 547.53 | 210.72 | 734.87 | 678.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 812.34 | 467.95 | 344.39 | 916.99 | 425.45 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 644.09 | 187.85 | 210.72 | 717.90 | 175.94 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1015.43 | 730.33 | 456.25 | 1134.65 | 778.68 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 452.69 | 182.44 | 270.26 | 242.45 | 1673.69 | 0.00 | 0.00 | 0.00 |
February | 772.68 | 379.81 | 392.87 | 615.09 | 1223.53 | 0.00 | 0.00 | 0.00 |
March | 988.84 | 362.33 | 626.52 | 825.86 | 1018.47 | 0.00 | 0.00 | 0.00 |
April | 1290.94 | 571.94 | 718.99 | 1297.87 | 739.11 | 0.00 | 0.00 | 0.00 |
May | 1596.80 | 728.22 | 868.58 | 1732.73 | 600.46 | 0.00 | 0.00 | 0.00 |
June | 1737.26 | 797.98 | 939.27 | 2090.42 | 416.69 | 0.00 | 0.00 | 0.00 |
July | 1779.63 | 899.27 | 880.36 | 2312.82 | 354.55 | 0.00 | 0.00 | 0.00 |
August | 1511.14 | 741.63 | 769.51 | 1911.89 | 384.35 | 0.00 | 0.00 | 0.00 |
September | 1215.62 | 614.57 | 601.05 | 1410.67 | 557.16 | 0.00 | 0.00 | 0.00 |
October | 868.83 | 431.68 | 437.16 | 848.79 | 801.73 | 0.00 | 0.00 | 0.00 |
November | 615.05 | 305.12 | 309.93 | 490.69 | 1073.18 | 0.00 | 0.00 | 0.00 |
December | 413.43 | 174.50 | 238.93 | 231.73 | 1438.98 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1105.08 | 516.29 | 588.79 | 1170.43 | 855.57 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 413.43 | 174.50 | 238.93 | 231.73 | 354.55 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1779.63 | 899.27 | 939.27 | 2312.82 | 1673.69 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 17.90 | 7.21 | 10.69 | 9.59 | 66.18 | 0.00 | 0.00 | 0.00 |
February | 30.55 | 15.02 | 15.53 | 24.32 | 48.38 | 0.00 | 0.00 | 0.00 |
March | 39.10 | 14.33 | 24.77 | 32.65 | 40.27 | 0.00 | 0.00 | 0.00 |
April | 51.04 | 22.61 | 28.43 | 51.32 | 29.22 | 0.00 | 0.00 | 0.00 |
May | 63.14 | 28.79 | 34.34 | 68.51 | 23.74 | 0.00 | 0.00 | 0.00 |
June | 68.69 | 31.55 | 37.14 | 82.65 | 16.48 | 0.00 | 0.00 | 0.00 |
July | 70.36 | 35.56 | 34.81 | 91.45 | 14.02 | 0.00 | 0.00 | 0.00 |
August | 59.75 | 29.32 | 30.43 | 75.59 | 15.20 | 0.00 | 0.00 | 0.00 |
September | 48.06 | 24.30 | 23.77 | 55.78 | 22.03 | 0.00 | 0.00 | 0.00 |
October | 34.35 | 17.07 | 17.28 | 33.56 | 31.70 | 0.00 | 0.00 | 0.00 |
November | 24.32 | 12.06 | 12.25 | 19.40 | 42.43 | 0.00 | 0.00 | 0.00 |
December | 16.35 | 6.90 | 9.45 | 9.16 | 56.90 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 43.69 | 20.41 | 23.28 | 46.28 | 33.83 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 16.35 | 6.90 | 9.45 | 9.16 | 14.02 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 70.36 | 35.56 | 37.14 | 91.45 | 66.18 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 339.38 | 0.00 | 339.38 | 11.51 | 2751.08 | 0.00 | 0.00 | 0.00 |
February | 479.19 | 0.00 | 479.19 | 87.08 | 2046.37 | 0.00 | 0.00 | 0.00 |
March | 778.42 | 0.00 | 778.42 | 286.63 | 1650.37 | 0.00 | 0.00 | 0.00 |
April | 887.57 | 5.18 | 882.39 | 481.73 | 1179.16 | 0.00 | 0.00 | 0.00 |
May | 1165.59 | 69.07 | 1096.52 | 874.57 | 888.81 | 0.00 | 0.00 | 0.00 |
June | 1357.26 | 156.01 | 1201.26 | 1384.46 | 575.04 | 0.00 | 0.00 | 0.00 |
July | 1239.93 | 116.13 | 1123.80 | 1498.71 | 481.80 | 0.00 | 0.00 | 0.00 |
August | 993.57 | 26.63 | 966.93 | 1092.08 | 550.36 | 0.00 | 0.00 | 0.00 |
September | 744.11 | 0.27 | 743.84 | 638.12 | 841.37 | 0.00 | 0.00 | 0.00 |
October | 542.79 | 0.00 | 542.79 | 250.38 | 1229.40 | 0.00 | 0.00 | 0.00 |
November | 368.99 | 0.00 | 368.99 | 62.16 | 1729.71 | 0.00 | 0.00 | 0.00 |
December | 284.59 | 0.00 | 284.59 | 6.86 | 2359.92 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 766.65 | 31.26 | 735.39 | 559.11 | 1354.30 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 284.59 | 0.00 | 284.59 | 6.86 | 481.80 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1357.26 | 156.01 | 1201.26 | 1498.71 | 2751.08 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_2_WALL_EAST_WINDOW
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 519.55 | 238.19 | 281.36 | 281.82 | 1687.57 | 0.00 | 0.00 | 0.00 |
February | 812.62 | 403.44 | 409.17 | 615.92 | 1254.74 | 0.00 | 0.00 | 0.00 |
March | 1092.64 | 452.10 | 640.53 | 902.16 | 1036.47 | 0.00 | 0.00 | 0.00 |
April | 1394.10 | 690.90 | 703.19 | 1354.07 | 750.77 | 0.00 | 0.00 | 0.00 |
May | 1539.96 | 685.19 | 854.78 | 1598.26 | 594.82 | 0.00 | 0.00 | 0.00 |
June | 1993.28 | 1025.74 | 967.54 | 2370.55 | 391.98 | 0.00 | 0.00 | 0.00 |
July | 2092.00 | 1182.67 | 909.34 | 2680.89 | 321.76 | 0.00 | 0.00 | 0.00 |
August | 1818.05 | 1012.96 | 805.09 | 2276.28 | 362.50 | 0.00 | 0.00 | 0.00 |
September | 1286.09 | 663.87 | 622.21 | 1461.63 | 526.78 | 0.00 | 0.00 | 0.00 |
October | 922.70 | 468.53 | 454.17 | 875.69 | 767.87 | 0.00 | 0.00 | 0.00 |
November | 584.79 | 273.02 | 311.77 | 410.00 | 1054.47 | 0.00 | 0.00 | 0.00 |
December | 431.32 | 185.25 | 246.07 | 221.43 | 1446.63 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1209.33 | 607.87 | 601.45 | 1257.71 | 848.21 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 431.32 | 185.25 | 246.07 | 221.43 | 321.76 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2092.00 | 1182.67 | 967.54 | 2680.89 | 1687.57 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 2392.28 | 1708.62 | 683.67 | 2236.16 | 2378.16 | 0.00 | 0.00 | 0.00 |
February | 3046.54 | 2191.18 | 855.35 | 3125.97 | 1803.69 | 0.00 | 0.00 | 0.00 |
March | 2723.21 | 1529.23 | 1193.98 | 2786.81 | 1614.95 | 0.00 | 0.00 | 0.00 |
April | 2189.00 | 1047.01 | 1141.99 | 2323.18 | 1212.51 | 0.00 | 0.00 | 0.00 |
May | 1944.87 | 645.95 | 1298.93 | 2097.44 | 964.74 | 0.00 | 0.00 | 0.00 |
June | 1932.43 | 563.59 | 1368.84 | 2374.36 | 664.39 | 0.00 | 0.00 | 0.00 |
July | 2083.35 | 769.58 | 1313.77 | 2854.85 | 530.70 | 0.00 | 0.00 | 0.00 |
August | 2475.92 | 1248.32 | 1227.61 | 3293.63 | 596.19 | 0.00 | 0.00 | 0.00 |
September | 2746.10 | 1682.62 | 1063.47 | 3385.34 | 852.21 | 0.00 | 0.00 | 0.00 |
October | 2870.90 | 1985.19 | 885.71 | 3251.61 | 1193.66 | 0.00 | 0.00 | 0.00 |
November | 2617.41 | 1895.95 | 721.46 | 2709.90 | 1527.65 | 0.00 | 0.00 | 0.00 |
December | 2274.93 | 1642.73 | 632.20 | 2176.43 | 2035.71 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 2437.21 | 1403.96 | 1033.24 | 2714.84 | 1279.30 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 1932.43 | 563.59 | 632.20 | 2097.44 | 530.70 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 3046.54 | 2191.18 | 1368.84 | 3385.34 | 2378.16 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_4_WALL_WEST_WINDOW
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 470.60 | 189.65 | 280.94 | 246.26 | 1758.24 | 0.00 | 0.00 | 0.00 |
February | 803.24 | 394.83 | 408.41 | 623.93 | 1290.77 | 0.00 | 0.00 | 0.00 |
March | 1027.95 | 376.66 | 651.30 | 833.84 | 1083.62 | 0.00 | 0.00 | 0.00 |
April | 1342.00 | 594.57 | 747.43 | 1318.12 | 797.09 | 0.00 | 0.00 | 0.00 |
May | 1659.96 | 757.03 | 902.93 | 1776.46 | 634.62 | 0.00 | 0.00 | 0.00 |
June | 1805.97 | 829.55 | 976.42 | 2155.27 | 436.61 | 0.00 | 0.00 | 0.00 |
July | 1850.01 | 934.84 | 915.17 | 2394.74 | 364.18 | 0.00 | 0.00 | 0.00 |
August | 1570.91 | 770.97 | 799.94 | 1979.55 | 394.86 | 0.00 | 0.00 | 0.00 |
September | 1263.70 | 638.88 | 624.82 | 1461.38 | 565.67 | 0.00 | 0.00 | 0.00 |
October | 903.20 | 448.75 | 454.45 | 881.13 | 810.36 | 0.00 | 0.00 | 0.00 |
November | 639.38 | 317.19 | 322.19 | 506.35 | 1098.35 | 0.00 | 0.00 | 0.00 |
December | 429.78 | 181.40 | 248.38 | 236.46 | 1491.62 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1148.79 | 536.71 | 612.08 | 1204.12 | 892.43 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 429.78 | 181.40 | 248.38 | 236.46 | 364.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1850.01 | 934.84 | 976.42 | 2394.74 | 1758.24 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.909008E+09 | 0.00 | 0.909008E+09 | 40368865.92 | 0.714764E+10 |
February | 0.115926E+10 | 0.00 | 0.115926E+10 | 0.235977E+09 | 0.474897E+10 |
March | 0.208493E+10 | 0.00 | 0.208493E+10 | 0.814672E+09 | 0.420323E+10 |
April | 0.230057E+10 | 13425633.98 | 0.228715E+10 | 0.129722E+10 | 0.287605E+10 |
May | 0.312191E+10 | 0.184993E+09 | 0.293692E+10 | 0.238775E+10 | 0.225348E+10 |
June | 0.351802E+10 | 0.404367E+09 | 0.311366E+10 | 0.360959E+10 | 0.143707E+10 |
July | 0.332104E+10 | 0.311055E+09 | 0.300998E+10 | 0.402297E+10 | 0.125152E+10 |
August | 0.266116E+10 | 71331635.12 | 0.258983E+10 | 0.293987E+10 | 0.141330E+10 |
September | 0.192874E+10 | 692135.30 | 0.192804E+10 | 0.168704E+10 | 0.205131E+10 |
October | 0.145380E+10 | 0.00 | 0.145380E+10 | 0.732391E+09 | 0.305467E+10 |
November | 0.956425E+09 | 0.00 | 0.956425E+09 | 0.189478E+09 | 0.419591E+10 |
December | 0.762255E+09 | 0.00 | 0.762255E+09 | 22197141.10 | 0.605430E+10 |
Annual Sum or Average | 0.241771E+11 | 0.985864E+09 | 0.231913E+11 | 0.179795E+11 | 0.406875E+11 |
Minimum of Months | 0.762255E+09 | 0.00 | 0.762255E+09 | 22197141.10 | 0.125152E+10 |
Maximum of Months | 0.351802E+10 | 0.404367E+09 | 0.311366E+10 | 0.402297E+10 | 0.714764E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.139155E+10 | 0.637971E+09 | 0.753582E+09 | 0.772987E+09 | 0.438553E+10 |
February | 0.196588E+10 | 0.976014E+09 | 0.989869E+09 | 0.151961E+10 | 0.291546E+10 |
March | 0.292652E+10 | 0.121091E+10 | 0.171561E+10 | 0.245262E+10 | 0.264704E+10 |
April | 0.361350E+10 | 0.179082E+10 | 0.182268E+10 | 0.353965E+10 | 0.184507E+10 |
May | 0.412464E+10 | 0.183520E+10 | 0.228943E+10 | 0.430173E+10 | 0.151616E+10 |
June | 0.516659E+10 | 0.265872E+10 | 0.250786E+10 | 0.614956E+10 | 0.983379E+09 |
July | 0.560323E+10 | 0.316765E+10 | 0.243557E+10 | 0.717849E+10 | 0.836921E+09 |
August | 0.486945E+10 | 0.271311E+10 | 0.215634E+10 | 0.609958E+10 | 0.935574E+09 |
September | 0.333354E+10 | 0.172076E+10 | 0.161278E+10 | 0.380742E+10 | 0.129659E+10 |
October | 0.247136E+10 | 0.125492E+10 | 0.121644E+10 | 0.239040E+10 | 0.192383E+10 |
November | 0.151578E+10 | 0.707668E+09 | 0.808108E+09 | 0.110257E+10 | 0.256986E+10 |
December | 0.115524E+10 | 0.496178E+09 | 0.659061E+09 | 0.613017E+09 | 0.371353E+10 |
Annual Sum or Average | 0.381373E+11 | 0.191699E+11 | 0.189673E+11 | 0.399276E+11 | 0.255689E+11 |
Minimum of Months | 0.115524E+10 | 0.496178E+09 | 0.659061E+09 | 0.613017E+09 | 0.836921E+09 |
Maximum of Months | 0.560323E+10 | 0.316765E+10 | 0.250786E+10 | 0.717849E+10 | 0.438553E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.640749E+10 | 0.457636E+10 | 0.183113E+10 | 0.603104E+10 | 0.615941E+10 |
February | 0.737018E+10 | 0.530091E+10 | 0.206927E+10 | 0.760841E+10 | 0.417575E+10 |
March | 0.729384E+10 | 0.409588E+10 | 0.319795E+10 | 0.751141E+10 | 0.411496E+10 |
April | 0.567389E+10 | 0.271386E+10 | 0.296003E+10 | 0.606000E+10 | 0.297125E+10 |
May | 0.520915E+10 | 0.173010E+10 | 0.347905E+10 | 0.564593E+10 | 0.244911E+10 |
June | 0.500885E+10 | 0.146082E+10 | 0.354803E+10 | 0.616192E+10 | 0.165227E+10 |
July | 0.558004E+10 | 0.206125E+10 | 0.351879E+10 | 0.764588E+10 | 0.136992E+10 |
August | 0.663152E+10 | 0.334349E+10 | 0.328803E+10 | 0.882396E+10 | 0.152855E+10 |
September | 0.711789E+10 | 0.436136E+10 | 0.275653E+10 | 0.879459E+10 | 0.208862E+10 |
October | 0.768941E+10 | 0.531713E+10 | 0.237228E+10 | 0.876351E+10 | 0.298730E+10 |
November | 0.678432E+10 | 0.491429E+10 | 0.187003E+10 | 0.709856E+10 | 0.371864E+10 |
December | 0.609317E+10 | 0.439988E+10 | 0.169328E+10 | 0.588944E+10 | 0.520820E+10 |
Annual Sum or Average | 0.768598E+11 | 0.442753E+11 | 0.325844E+11 | 0.860347E+11 | 0.384240E+11 |
Minimum of Months | 0.500885E+10 | 0.146082E+10 | 0.169328E+10 | 0.564593E+10 | 0.136992E+10 |
Maximum of Months | 0.768941E+10 | 0.531713E+10 | 0.354803E+10 | 0.882396E+10 | 0.615941E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.126045E+10 | 0.507971E+09 | 0.752480E+09 | 0.670377E+09 | 0.456974E+10 |
February | 0.194320E+10 | 0.955182E+09 | 0.988019E+09 | 0.152915E+10 | 0.299366E+10 |
March | 0.275327E+10 | 0.100884E+10 | 0.174443E+10 | 0.225946E+10 | 0.276453E+10 |
April | 0.347846E+10 | 0.154112E+10 | 0.193734E+10 | 0.344471E+10 | 0.195505E+10 |
May | 0.444603E+10 | 0.202763E+10 | 0.241840E+10 | 0.477844E+10 | 0.161272E+10 |
June | 0.468107E+10 | 0.215019E+10 | 0.253088E+10 | 0.559403E+10 | 0.108676E+10 |
July | 0.495508E+10 | 0.250387E+10 | 0.245120E+10 | 0.641649E+10 | 0.941649E+09 |
August | 0.420753E+10 | 0.206497E+10 | 0.214256E+10 | 0.530977E+10 | 0.101247E+10 |
September | 0.327551E+10 | 0.165596E+10 | 0.161954E+10 | 0.380797E+10 | 0.138381E+10 |
October | 0.241913E+10 | 0.120193E+10 | 0.121719E+10 | 0.239795E+10 | 0.202331E+10 |
November | 0.165727E+10 | 0.822147E+09 | 0.835122E+09 | 0.134125E+10 | 0.267353E+10 |
December | 0.115112E+10 | 0.485855E+09 | 0.665265E+09 | 0.647493E+09 | 0.382892E+10 |
Annual Sum or Average | 0.362281E+11 | 0.169257E+11 | 0.193024E+11 | 0.381971E+11 | 0.268462E+11 |
Minimum of Months | 0.115112E+10 | 0.485855E+09 | 0.665265E+09 | 0.647493E+09 | 0.941649E+09 |
Maximum of Months | 0.495508E+10 | 0.250387E+10 | 0.253088E+10 | 0.641649E+10 | 0.456974E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.302988E+09 | 0.00 | 0.302988E+09 | 11264721.70 | 0.242392E+10 |
February | 0.386400E+09 | 0.00 | 0.386400E+09 | 78848646.09 | 0.161069E+10 |
March | 0.694943E+09 | 0.00 | 0.694943E+09 | 0.284714E+09 | 0.141883E+10 |
April | 0.766822E+09 | 4474999.60 | 0.762347E+09 | 0.462016E+09 | 0.949615E+09 |
May | 0.104059E+10 | 61661249.44 | 0.978926E+09 | 0.831059E+09 | 0.751756E+09 |
June | 0.117262E+10 | 0.134783E+09 | 0.103784E+10 | 0.122914E+10 | 0.475308E+09 |
July | 0.110696E+10 | 0.103680E+09 | 0.100328E+10 | 0.135971E+10 | 0.415134E+09 |
August | 0.887013E+09 | 23776086.76 | 0.863237E+09 | 0.991246E+09 | 0.477209E+09 |
September | 0.642882E+09 | 230700.85 | 0.642651E+09 | 0.562879E+09 | 0.717968E+09 |
October | 0.484576E+09 | 0.00 | 0.484576E+09 | 0.227876E+09 | 0.110390E+10 |
November | 0.318793E+09 | 0.00 | 0.318793E+09 | 55682003.34 | 0.150079E+10 |
December | 0.254073E+09 | 0.00 | 0.254073E+09 | 6914475.19 | 0.210634E+10 |
Annual Sum or Average | 0.805866E+10 | 0.328606E+09 | 0.773005E+10 | 0.610136E+10 | 0.139515E+11 |
Minimum of Months | 0.254073E+09 | 0.00 | 0.254073E+09 | 6914475.19 | 0.415134E+09 |
Maximum of Months | 0.117262E+10 | 0.134783E+09 | 0.103784E+10 | 0.135971E+10 | 0.242392E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.303000E+09 | 0.00 | 0.303000E+09 | 11264106.94 | 0.242407E+10 |
February | 0.386416E+09 | 0.00 | 0.386416E+09 | 78848941.64 | 0.161080E+10 |
March | 0.694970E+09 | 0.00 | 0.694970E+09 | 0.284716E+09 | 0.141892E+10 |
April | 0.766852E+09 | 4475119.89 | 0.762377E+09 | 0.462028E+09 | 0.949675E+09 |
May | 0.104063E+10 | 61662906.91 | 0.978965E+09 | 0.831082E+09 | 0.751803E+09 |
June | 0.117267E+10 | 0.134786E+09 | 0.103788E+10 | 0.122919E+10 | 0.475337E+09 |
July | 0.110701E+10 | 0.103683E+09 | 0.100332E+10 | 0.135977E+10 | 0.415157E+09 |
August | 0.887050E+09 | 23776725.87 | 0.863273E+09 | 0.991287E+09 | 0.477237E+09 |
September | 0.642908E+09 | 230707.05 | 0.642677E+09 | 0.562900E+09 | 0.718011E+09 |
October | 0.484596E+09 | 0.00 | 0.484596E+09 | 0.227880E+09 | 0.110397E+10 |
November | 0.318806E+09 | 0.00 | 0.318806E+09 | 55681934.19 | 0.150089E+10 |
December | 0.254083E+09 | 0.00 | 0.254083E+09 | 6914060.65 | 0.210647E+10 |
Annual Sum or Average | 0.805898E+10 | 0.328615E+09 | 0.773036E+10 | 0.610156E+10 | 0.139523E+11 |
Minimum of Months | 0.254083E+09 | 0.00 | 0.254083E+09 | 6914060.65 | 0.415157E+09 |
Maximum of Months | 0.117267E+10 | 0.134786E+09 | 0.103788E+10 | 0.135977E+10 | 0.242407E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.303000E+09 | 0.00 | 0.303000E+09 | 11264106.94 | 0.242407E+10 |
February | 0.386416E+09 | 0.00 | 0.386416E+09 | 78848941.64 | 0.161080E+10 |
March | 0.694970E+09 | 0.00 | 0.694970E+09 | 0.284716E+09 | 0.141892E+10 |
April | 0.766852E+09 | 4475119.89 | 0.762377E+09 | 0.462028E+09 | 0.949675E+09 |
May | 0.104063E+10 | 61662906.91 | 0.978965E+09 | 0.831082E+09 | 0.751803E+09 |
June | 0.117267E+10 | 0.134786E+09 | 0.103788E+10 | 0.122919E+10 | 0.475337E+09 |
July | 0.110701E+10 | 0.103683E+09 | 0.100332E+10 | 0.135977E+10 | 0.415157E+09 |
August | 0.887050E+09 | 23776725.87 | 0.863273E+09 | 0.991287E+09 | 0.477237E+09 |
September | 0.642908E+09 | 230707.05 | 0.642677E+09 | 0.562900E+09 | 0.718011E+09 |
October | 0.484596E+09 | 0.00 | 0.484596E+09 | 0.227880E+09 | 0.110397E+10 |
November | 0.318806E+09 | 0.00 | 0.318806E+09 | 55681934.19 | 0.150089E+10 |
December | 0.254083E+09 | 0.00 | 0.254083E+09 | 6914060.65 | 0.210647E+10 |
Annual Sum or Average | 0.805898E+10 | 0.328615E+09 | 0.773036E+10 | 0.610156E+10 | 0.139523E+11 |
Minimum of Months | 0.254083E+09 | 0.00 | 0.254083E+09 | 6914060.65 | 0.415157E+09 |
Maximum of Months | 0.117267E+10 | 0.134786E+09 | 0.103788E+10 | 0.135977E+10 | 0.242407E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.133860E+10 | 0.613693E+09 | 0.724910E+09 | 0.739845E+09 | 0.431484E+10 |
February | 0.189108E+10 | 0.938873E+09 | 0.952207E+09 | 0.146428E+10 | 0.288044E+10 |
March | 0.281516E+10 | 0.116483E+10 | 0.165033E+10 | 0.238284E+10 | 0.262230E+10 |
April | 0.347601E+10 | 0.172268E+10 | 0.175333E+10 | 0.344520E+10 | 0.181791E+10 |
May | 0.396769E+10 | 0.176537E+10 | 0.220233E+10 | 0.417890E+10 | 0.150585E+10 |
June | 0.496999E+10 | 0.255755E+10 | 0.241245E+10 | 0.595072E+10 | 0.976284E+09 |
July | 0.539002E+10 | 0.304711E+10 | 0.234291E+10 | 0.693003E+10 | 0.845456E+09 |
August | 0.468417E+10 | 0.260986E+10 | 0.207430E+10 | 0.588386E+10 | 0.953574E+09 |
September | 0.320670E+10 | 0.165528E+10 | 0.155142E+10 | 0.365533E+10 | 0.135230E+10 |
October | 0.237733E+10 | 0.120717E+10 | 0.117016E+10 | 0.225610E+10 | 0.204538E+10 |
November | 0.145810E+10 | 0.680739E+09 | 0.777361E+09 | 0.102384E+10 | 0.267728E+10 |
December | 0.111128E+10 | 0.477296E+09 | 0.633985E+09 | 0.576752E+09 | 0.374067E+10 |
Annual Sum or Average | 0.366861E+11 | 0.184404E+11 | 0.182457E+11 | 0.384877E+11 | 0.257323E+11 |
Minimum of Months | 0.111128E+10 | 0.477296E+09 | 0.633985E+09 | 0.576752E+09 | 0.845456E+09 |
Maximum of Months | 0.539002E+10 | 0.304711E+10 | 0.241245E+10 | 0.693003E+10 | 0.431484E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 52927167.64 | 24264883.73 | 28662283.91 | 29252809.85 | 0.170605E+09 |
February | 74771572.24 | 37122182.26 | 37649389.99 | 57896428.73 | 0.113890E+09 |
March | 0.111309E+09 | 46056402.48 | 65252643.09 | 94215447.55 | 0.103683E+09 |
April | 0.137438E+09 | 68113079.73 | 69325033.87 | 0.136220E+09 | 71878610.36 |
May | 0.156879E+09 | 69801028.93 | 87077951.22 | 0.165230E+09 | 59540106.33 |
June | 0.196509E+09 | 0.101123E+09 | 95386044.30 | 0.235286E+09 | 38601383.47 |
July | 0.213117E+09 | 0.120480E+09 | 92636517.15 | 0.274007E+09 | 33428554.45 |
August | 0.185208E+09 | 0.103192E+09 | 82016115.23 | 0.232642E+09 | 37703476.66 |
September | 0.126790E+09 | 65448262.81 | 61341707.84 | 0.144528E+09 | 53468550.94 |
October | 93997321.50 | 47730217.26 | 46267104.23 | 89204270.93 | 80872468.25 |
November | 57651956.98 | 26915793.88 | 30736163.10 | 40481638.64 | 0.105857E+09 |
December | 43939043.72 | 18871857.87 | 25067185.85 | 22804252.93 | 0.147903E+09 |
Annual Sum or Average | 0.145054E+10 | 0.729118E+09 | 0.721418E+09 | 0.152177E+10 | 0.101743E+10 |
Minimum of Months | 43939043.72 | 18871857.87 | 25067185.85 | 22804252.93 | 33428554.45 |
Maximum of Months | 0.213117E+09 | 0.120480E+09 | 95386044.30 | 0.274007E+09 | 0.170605E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.213579E+10 | 0.152542E+10 | 0.610369E+09 | 0.203717E+10 | 0.208574E+10 |
February | 0.245668E+10 | 0.176693E+10 | 0.689748E+09 | 0.256664E+10 | 0.144761E+10 |
March | 0.243124E+10 | 0.136527E+10 | 0.106597E+10 | 0.253928E+10 | 0.142400E+10 |
April | 0.189127E+10 | 0.904601E+09 | 0.986668E+09 | 0.205524E+10 | 0.101062E+10 |
May | 0.173636E+10 | 0.576688E+09 | 0.115967E+10 | 0.192295E+10 | 0.826852E+09 |
June | 0.166960E+10 | 0.486930E+09 | 0.118267E+10 | 0.208671E+10 | 0.553605E+09 |
July | 0.185999E+10 | 0.687070E+09 | 0.117292E+10 | 0.256789E+10 | 0.471262E+09 |
August | 0.221047E+10 | 0.111447E+10 | 0.109600E+10 | 0.295757E+10 | 0.538472E+09 |
September | 0.237259E+10 | 0.145376E+10 | 0.918833E+09 | 0.294120E+10 | 0.762765E+09 |
October | 0.256309E+10 | 0.177234E+10 | 0.790751E+09 | 0.291796E+10 | 0.111844E+10 |
November | 0.226140E+10 | 0.163806E+10 | 0.623335E+09 | 0.235886E+10 | 0.136077E+10 |
December | 0.203102E+10 | 0.146660E+10 | 0.564419E+09 | 0.196841E+10 | 0.181767E+10 |
Annual Sum or Average | 0.256195E+11 | 0.147581E+11 | 0.108614E+11 | 0.289199E+11 | 0.134178E+11 |
Minimum of Months | 0.166960E+10 | 0.486930E+09 | 0.564419E+09 | 0.192295E+10 | 0.471262E+09 |
Maximum of Months | 0.256309E+10 | 0.177234E+10 | 0.118267E+10 | 0.295757E+10 | 0.208574E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.213579E+10 | 0.152542E+10 | 0.610369E+09 | 0.203717E+10 | 0.208574E+10 |
February | 0.245668E+10 | 0.176693E+10 | 0.689748E+09 | 0.256664E+10 | 0.144761E+10 |
March | 0.243124E+10 | 0.136527E+10 | 0.106597E+10 | 0.253928E+10 | 0.142400E+10 |
April | 0.189127E+10 | 0.904601E+09 | 0.986668E+09 | 0.205524E+10 | 0.101062E+10 |
May | 0.173636E+10 | 0.576688E+09 | 0.115967E+10 | 0.192295E+10 | 0.826852E+09 |
June | 0.166960E+10 | 0.486930E+09 | 0.118267E+10 | 0.208671E+10 | 0.553605E+09 |
July | 0.185999E+10 | 0.687070E+09 | 0.117292E+10 | 0.256789E+10 | 0.471262E+09 |
August | 0.221047E+10 | 0.111447E+10 | 0.109600E+10 | 0.295757E+10 | 0.538472E+09 |
September | 0.237259E+10 | 0.145376E+10 | 0.918833E+09 | 0.294120E+10 | 0.762765E+09 |
October | 0.256309E+10 | 0.177234E+10 | 0.790751E+09 | 0.291796E+10 | 0.111844E+10 |
November | 0.226140E+10 | 0.163806E+10 | 0.623335E+09 | 0.235886E+10 | 0.136077E+10 |
December | 0.203102E+10 | 0.146660E+10 | 0.564419E+09 | 0.196841E+10 | 0.181767E+10 |
Annual Sum or Average | 0.256195E+11 | 0.147581E+11 | 0.108614E+11 | 0.289199E+11 | 0.134178E+11 |
Minimum of Months | 0.166960E+10 | 0.486930E+09 | 0.564419E+09 | 0.192295E+10 | 0.471262E+09 |
Maximum of Months | 0.256309E+10 | 0.177234E+10 | 0.118267E+10 | 0.295757E+10 | 0.208574E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.213566E+10 | 0.152533E+10 | 0.610330E+09 | 0.203704E+10 | 0.208561E+10 |
February | 0.245653E+10 | 0.176682E+10 | 0.689705E+09 | 0.256648E+10 | 0.144752E+10 |
March | 0.243108E+10 | 0.136518E+10 | 0.106590E+10 | 0.253912E+10 | 0.142391E+10 |
April | 0.189115E+10 | 0.904544E+09 | 0.986605E+09 | 0.205511E+10 | 0.101055E+10 |
May | 0.173625E+10 | 0.576652E+09 | 0.115960E+10 | 0.192283E+10 | 0.826800E+09 |
June | 0.166949E+10 | 0.486899E+09 | 0.118259E+10 | 0.208658E+10 | 0.553570E+09 |
July | 0.185987E+10 | 0.687026E+09 | 0.117285E+10 | 0.256773E+10 | 0.471233E+09 |
August | 0.221033E+10 | 0.111440E+10 | 0.109593E+10 | 0.295738E+10 | 0.538438E+09 |
September | 0.237244E+10 | 0.145366E+10 | 0.918775E+09 | 0.294101E+10 | 0.762717E+09 |
October | 0.256293E+10 | 0.177223E+10 | 0.790701E+09 | 0.291778E+10 | 0.111837E+10 |
November | 0.226126E+10 | 0.163796E+10 | 0.623296E+09 | 0.235871E+10 | 0.136069E+10 |
December | 0.203089E+10 | 0.146650E+10 | 0.564384E+09 | 0.196829E+10 | 0.181755E+10 |
Annual Sum or Average | 0.256179E+11 | 0.147572E+11 | 0.108607E+11 | 0.289181E+11 | 0.134170E+11 |
Minimum of Months | 0.166949E+10 | 0.486899E+09 | 0.564384E+09 | 0.192283E+10 | 0.471233E+09 |
Maximum of Months | 0.256293E+10 | 0.177223E+10 | 0.118259E+10 | 0.295738E+10 | 0.208561E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.121249E+10 | 0.488643E+09 | 0.723851E+09 | 0.649366E+09 | 0.448282E+10 |
February | 0.186927E+10 | 0.918836E+09 | 0.950429E+09 | 0.148802E+10 | 0.295997E+10 |
March | 0.264851E+10 | 0.970452E+09 | 0.167806E+10 | 0.221199E+10 | 0.272787E+10 |
April | 0.334611E+10 | 0.148248E+10 | 0.186363E+10 | 0.336407E+10 | 0.191578E+10 |
May | 0.427686E+10 | 0.195047E+10 | 0.232639E+10 | 0.464095E+10 | 0.160826E+10 |
June | 0.450297E+10 | 0.206837E+10 | 0.243459E+10 | 0.541837E+10 | 0.108007E+10 |
July | 0.476655E+10 | 0.240860E+10 | 0.235795E+10 | 0.619465E+10 | 0.949624E+09 |
August | 0.404744E+10 | 0.198639E+10 | 0.206105E+10 | 0.512081E+10 | 0.102946E+10 |
September | 0.315088E+10 | 0.159295E+10 | 0.155793E+10 | 0.365646E+10 | 0.144417E+10 |
October | 0.232708E+10 | 0.115620E+10 | 0.117088E+10 | 0.227339E+10 | 0.214734E+10 |
November | 0.159421E+10 | 0.790863E+09 | 0.803349E+09 | 0.127187E+10 | 0.278167E+10 |
December | 0.110732E+10 | 0.467368E+09 | 0.639954E+09 | 0.620672E+09 | 0.385417E+10 |
Annual Sum or Average | 0.348497E+11 | 0.162816E+11 | 0.185681E+11 | 0.369106E+11 | 0.269812E+11 |
Minimum of Months | 0.110732E+10 | 0.467368E+09 | 0.639954E+09 | 0.620672E+09 | 0.949624E+09 |
Maximum of Months | 0.476655E+10 | 0.240860E+10 | 0.243459E+10 | 0.619465E+10 | 0.448282E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 47940791.39 | 19320428.56 | 28620362.83 | 25675209.09 | 0.177247E+09 |
February | 73908879.09 | 36329845.25 | 37579033.83 | 58834890.58 | 0.117035E+09 |
March | 0.104720E+09 | 38370693.06 | 66348889.56 | 87459637.00 | 0.107858E+09 |
April | 0.132302E+09 | 58615649.48 | 73686259.38 | 0.133012E+09 | 75748357.16 |
May | 0.169103E+09 | 77119687.82 | 91983232.37 | 0.183498E+09 | 63589290.12 |
June | 0.178043E+09 | 81781373.99 | 96261424.93 | 0.214237E+09 | 42705119.65 |
July | 0.188465E+09 | 95233511.60 | 93231038.90 | 0.244930E+09 | 37547270.33 |
August | 0.160032E+09 | 78539908.25 | 81491891.64 | 0.202472E+09 | 40703737.40 |
September | 0.124583E+09 | 62983752.76 | 61599007.06 | 0.144573E+09 | 57101013.21 |
October | 92010501.44 | 45714899.29 | 46295602.16 | 89887591.73 | 84903973.57 |
November | 63033538.01 | 31269916.93 | 31763621.08 | 50288484.05 | 0.109985E+09 |
December | 43782396.77 | 18479253.60 | 25303143.16 | 24540696.82 | 0.152390E+09 |
Annual Sum or Average | 0.137792E+10 | 0.643759E+09 | 0.734164E+09 | 0.145941E+10 | 0.106681E+10 |
Minimum of Months | 43782396.77 | 18479253.60 | 25303143.16 | 24540696.82 | 37547270.33 |
Maximum of Months | 0.188465E+09 | 95233511.60 | 96261424.93 | 0.244930E+09 | 0.177247E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.909008E+09 | 0.00 | 0.909008E+09 | 30841200.46 | 0.736849E+10 |
February | 0.115926E+10 | 0.00 | 0.115926E+10 | 0.210674E+09 | 0.495058E+10 |
March | 0.208493E+10 | 0.00 | 0.208493E+10 | 0.767705E+09 | 0.442035E+10 |
April | 0.230057E+10 | 13425633.98 | 0.228715E+10 | 0.124865E+10 | 0.305639E+10 |
May | 0.312191E+10 | 0.184993E+09 | 0.293692E+10 | 0.234244E+10 | 0.238058E+10 |
June | 0.351802E+10 | 0.404367E+09 | 0.311366E+10 | 0.358852E+10 | 0.149050E+10 |
July | 0.332104E+10 | 0.311055E+09 | 0.300998E+10 | 0.401413E+10 | 0.129045E+10 |
August | 0.266116E+10 | 71331635.12 | 0.258983E+10 | 0.292503E+10 | 0.147408E+10 |
September | 0.192874E+10 | 692135.30 | 0.192804E+10 | 0.165401E+10 | 0.218084E+10 |
October | 0.145380E+10 | 0.00 | 0.145380E+10 | 0.670622E+09 | 0.329281E+10 |
November | 0.956425E+09 | 0.00 | 0.956425E+09 | 0.161112E+09 | 0.448342E+10 |
December | 0.762255E+09 | 0.00 | 0.762255E+09 | 18372698.75 | 0.632082E+10 |
Annual Sum or Average | 0.241771E+11 | 0.985864E+09 | 0.231913E+11 | 0.176321E+11 | 0.427093E+11 |
Minimum of Months | 0.762255E+09 | 0.00 | 0.762255E+09 | 18372698.75 | 0.129045E+10 |
Maximum of Months | 0.351802E+10 | 0.404367E+09 | 0.311366E+10 | 0.401413E+10 | 0.736849E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_2_WALL_EAST_WINDOW
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.139155E+10 | 0.637971E+09 | 0.753582E+09 | 0.754837E+09 | 0.451998E+10 |
February | 0.196588E+10 | 0.976014E+09 | 0.989869E+09 | 0.149002E+10 | 0.303546E+10 |
March | 0.292652E+10 | 0.121091E+10 | 0.171561E+10 | 0.241634E+10 | 0.277608E+10 |
April | 0.361350E+10 | 0.179082E+10 | 0.182268E+10 | 0.350975E+10 | 0.194598E+10 |
May | 0.412464E+10 | 0.183520E+10 | 0.228943E+10 | 0.428079E+10 | 0.159316E+10 |
June | 0.516659E+10 | 0.265872E+10 | 0.250786E+10 | 0.614445E+10 | 0.101601E+10 |
July | 0.560323E+10 | 0.316765E+10 | 0.243557E+10 | 0.718048E+10 | 0.861790E+09 |
August | 0.486945E+10 | 0.271311E+10 | 0.215634E+10 | 0.609679E+10 | 0.970913E+09 |
September | 0.333354E+10 | 0.172076E+10 | 0.161278E+10 | 0.378855E+10 | 0.136542E+10 |
October | 0.247136E+10 | 0.125492E+10 | 0.121644E+10 | 0.234545E+10 | 0.205667E+10 |
November | 0.151578E+10 | 0.707668E+09 | 0.808108E+09 | 0.106271E+10 | 0.273319E+10 |
December | 0.115524E+10 | 0.496178E+09 | 0.659061E+09 | 0.593075E+09 | 0.387464E+10 |
Annual Sum or Average | 0.381373E+11 | 0.191699E+11 | 0.189673E+11 | 0.396632E+11 | 0.267493E+11 |
Minimum of Months | 0.115524E+10 | 0.496178E+09 | 0.659061E+09 | 0.593075E+09 | 0.861790E+09 |
Maximum of Months | 0.560323E+10 | 0.316765E+10 | 0.250786E+10 | 0.718048E+10 | 0.451998E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.640749E+10 | 0.457636E+10 | 0.183113E+10 | 0.598932E+10 | 0.636967E+10 |
February | 0.737018E+10 | 0.530091E+10 | 0.206927E+10 | 0.756235E+10 | 0.436350E+10 |
March | 0.729384E+10 | 0.409588E+10 | 0.319795E+10 | 0.746419E+10 | 0.432547E+10 |
April | 0.567389E+10 | 0.271386E+10 | 0.296003E+10 | 0.602169E+10 | 0.314282E+10 |
May | 0.520915E+10 | 0.173010E+10 | 0.347905E+10 | 0.561779E+10 | 0.258396E+10 |
June | 0.500885E+10 | 0.146082E+10 | 0.354803E+10 | 0.615434E+10 | 0.172209E+10 |
July | 0.558004E+10 | 0.206125E+10 | 0.351879E+10 | 0.764643E+10 | 0.142144E+10 |
August | 0.663152E+10 | 0.334349E+10 | 0.328803E+10 | 0.882166E+10 | 0.159684E+10 |
September | 0.711789E+10 | 0.436136E+10 | 0.275653E+10 | 0.877480E+10 | 0.220892E+10 |
October | 0.768941E+10 | 0.531713E+10 | 0.237228E+10 | 0.870912E+10 | 0.319711E+10 |
November | 0.678432E+10 | 0.491429E+10 | 0.187003E+10 | 0.702406E+10 | 0.395966E+10 |
December | 0.609317E+10 | 0.439988E+10 | 0.169328E+10 | 0.582935E+10 | 0.545245E+10 |
Annual Sum or Average | 0.768598E+11 | 0.442753E+11 | 0.325844E+11 | 0.856151E+11 | 0.403439E+11 |
Minimum of Months | 0.500885E+10 | 0.146082E+10 | 0.169328E+10 | 0.561779E+10 | 0.142144E+10 |
Maximum of Months | 0.768941E+10 | 0.531713E+10 | 0.354803E+10 | 0.882166E+10 | 0.636967E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_4_WALL_WEST_WINDOW
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.126045E+10 | 0.507971E+09 | 0.752480E+09 | 0.659586E+09 | 0.470928E+10 |
February | 0.194320E+10 | 0.955182E+09 | 0.988019E+09 | 0.150942E+10 | 0.312263E+10 |
March | 0.275327E+10 | 0.100884E+10 | 0.174443E+10 | 0.223335E+10 | 0.290236E+10 |
April | 0.347846E+10 | 0.154112E+10 | 0.193734E+10 | 0.341657E+10 | 0.206605E+10 |
May | 0.444603E+10 | 0.202763E+10 | 0.241840E+10 | 0.475807E+10 | 0.169977E+10 |
June | 0.468107E+10 | 0.215019E+10 | 0.253088E+10 | 0.558647E+10 | 0.113170E+10 |
July | 0.495508E+10 | 0.250387E+10 | 0.245120E+10 | 0.641406E+10 | 0.975422E+09 |
August | 0.420753E+10 | 0.206497E+10 | 0.214256E+10 | 0.530203E+10 | 0.105759E+10 |
September | 0.327551E+10 | 0.165596E+10 | 0.161954E+10 | 0.378790E+10 | 0.146623E+10 |
October | 0.241913E+10 | 0.120193E+10 | 0.121719E+10 | 0.236002E+10 | 0.217047E+10 |
November | 0.165727E+10 | 0.822147E+09 | 0.835122E+09 | 0.131246E+10 | 0.284693E+10 |
December | 0.115112E+10 | 0.485855E+09 | 0.665265E+09 | 0.633330E+09 | 0.399516E+10 |
Annual Sum or Average | 0.362281E+11 | 0.169257E+11 | 0.193024E+11 | 0.379733E+11 | 0.281436E+11 |
Minimum of Months | 0.115112E+10 | 0.485855E+09 | 0.665265E+09 | 0.633330E+09 | 0.975422E+09 |
Maximum of Months | 0.495508E+10 | 0.250387E+10 | 0.253088E+10 | 0.641406E+10 | 0.470928E+10 |
Report: WindowZoneSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 15.07 | 2668.62 | 339.38 | 0.00 | 339.38 | 0.00 | 0.00 |
February | 97.54 | 1963.03 | 479.19 | 0.00 | 479.19 | 0.00 | 0.00 |
March | 304.16 | 1569.31 | 778.42 | 0.00 | 778.42 | 0.00 | 0.00 |
April | 500.47 | 1109.59 | 887.57 | 5.18 | 882.39 | 0.00 | 0.00 |
May | 891.48 | 841.35 | 1165.59 | 69.07 | 1096.52 | 0.00 | 0.00 |
June | 1392.59 | 554.43 | 1357.26 | 156.01 | 1201.26 | 0.00 | 0.00 |
July | 1502.01 | 467.26 | 1239.93 | 116.13 | 1123.80 | 0.00 | 0.00 |
August | 1097.62 | 527.67 | 993.57 | 26.63 | 966.93 | 0.00 | 0.00 |
September | 650.86 | 791.40 | 744.11 | 0.27 | 743.84 | 0.00 | 0.00 |
October | 273.44 | 1140.48 | 542.79 | 0.00 | 542.79 | 0.00 | 0.00 |
November | 73.10 | 1618.79 | 368.99 | 0.00 | 368.99 | 0.00 | 0.00 |
December | 8.29 | 2260.42 | 284.59 | 0.00 | 284.59 | 0.00 | 0.00 |
Annual Sum or Average | 570.13 | 1290.19 | 766.65 | 31.26 | 735.39 | 0.00 | 0.00 |
Minimum of Months | 8.29 | 467.26 | 284.59 | 0.00 | 284.59 | 0.00 | 0.00 |
Maximum of Months | 1502.01 | 2668.62 | 1357.26 | 156.01 | 1201.26 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 288.60 | 1637.37 | 519.55 | 238.19 | 281.36 | 0.00 | 0.00 |
February | 628.15 | 1205.13 | 812.62 | 403.44 | 409.17 | 0.00 | 0.00 |
March | 915.70 | 988.29 | 1092.64 | 452.10 | 640.53 | 0.00 | 0.00 |
April | 1365.60 | 711.83 | 1394.10 | 690.90 | 703.19 | 0.00 | 0.00 |
May | 1606.08 | 566.07 | 1539.96 | 685.19 | 854.78 | 0.00 | 0.00 |
June | 2372.51 | 379.39 | 1993.28 | 1025.74 | 967.54 | 0.00 | 0.00 |
July | 2680.14 | 312.47 | 2092.00 | 1182.67 | 909.34 | 0.00 | 0.00 |
August | 2277.32 | 349.30 | 1818.05 | 1012.96 | 805.09 | 0.00 | 0.00 |
September | 1468.91 | 500.23 | 1286.09 | 663.87 | 622.21 | 0.00 | 0.00 |
October | 892.47 | 718.27 | 922.70 | 468.53 | 454.17 | 0.00 | 0.00 |
November | 425.37 | 991.46 | 584.79 | 273.02 | 311.77 | 0.00 | 0.00 |
December | 228.87 | 1386.47 | 431.32 | 185.25 | 246.07 | 0.00 | 0.00 |
Annual Sum or Average | 1266.10 | 810.79 | 1209.33 | 607.87 | 601.45 | 0.00 | 0.00 |
Minimum of Months | 228.87 | 312.47 | 431.32 | 185.25 | 246.07 | 0.00 | 0.00 |
Maximum of Months | 2680.14 | 1637.37 | 2092.00 | 1182.67 | 967.54 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 2251.73 | 2299.66 | 2392.28 | 1708.62 | 683.67 | 0.00 | 0.00 |
February | 3145.01 | 1726.09 | 3046.54 | 2191.18 | 855.35 | 0.00 | 0.00 |
March | 2804.44 | 1536.35 | 2723.21 | 1529.23 | 1193.98 | 0.00 | 0.00 |
April | 2337.96 | 1146.32 | 2189.00 | 1047.01 | 1141.99 | 0.00 | 0.00 |
May | 2107.95 | 914.39 | 1944.87 | 645.95 | 1298.93 | 0.00 | 0.00 |
June | 2377.29 | 637.45 | 1932.43 | 563.59 | 1368.84 | 0.00 | 0.00 |
July | 2854.64 | 511.47 | 2083.35 | 769.58 | 1313.77 | 0.00 | 0.00 |
August | 3294.49 | 570.70 | 2475.92 | 1248.32 | 1227.61 | 0.00 | 0.00 |
September | 3392.98 | 805.80 | 2746.10 | 1682.62 | 1063.47 | 0.00 | 0.00 |
October | 3271.92 | 1115.33 | 2870.90 | 1985.19 | 885.71 | 0.00 | 0.00 |
November | 2738.64 | 1434.66 | 2617.41 | 1895.95 | 721.46 | 0.00 | 0.00 |
December | 2198.87 | 1944.52 | 2274.93 | 1642.73 | 632.20 | 0.00 | 0.00 |
Annual Sum or Average | 2728.14 | 1218.42 | 2437.21 | 1403.96 | 1033.24 | 0.00 | 0.00 |
Minimum of Months | 2107.95 | 511.47 | 1932.43 | 563.59 | 632.20 | 0.00 | 0.00 |
Maximum of Months | 3392.98 | 2299.66 | 3046.54 | 2191.18 | 1368.84 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 250.29 | 1706.15 | 470.60 | 189.65 | 280.94 | 0.00 | 0.00 |
February | 632.09 | 1237.46 | 803.24 | 394.83 | 408.41 | 0.00 | 0.00 |
March | 843.58 | 1032.16 | 1027.95 | 376.66 | 651.30 | 0.00 | 0.00 |
April | 1328.98 | 754.26 | 1342.00 | 594.57 | 747.43 | 0.00 | 0.00 |
May | 1784.06 | 602.12 | 1659.96 | 757.03 | 902.93 | 0.00 | 0.00 |
June | 2158.19 | 419.27 | 1805.97 | 829.55 | 976.42 | 0.00 | 0.00 |
July | 2395.64 | 351.57 | 1850.01 | 934.84 | 915.17 | 0.00 | 0.00 |
August | 1982.44 | 378.01 | 1570.91 | 770.97 | 799.94 | 0.00 | 0.00 |
September | 1469.12 | 533.88 | 1263.70 | 638.88 | 624.82 | 0.00 | 0.00 |
October | 895.29 | 755.42 | 903.20 | 448.75 | 454.45 | 0.00 | 0.00 |
November | 517.46 | 1031.46 | 639.38 | 317.19 | 322.19 | 0.00 | 0.00 |
December | 241.75 | 1429.56 | 429.78 | 181.40 | 248.38 | 0.00 | 0.00 |
Annual Sum or Average | 1211.22 | 851.29 | 1148.79 | 536.71 | 612.08 | 0.00 | 0.00 |
Minimum of Months | 241.75 | 351.57 | 429.78 | 181.40 | 248.38 | 0.00 | 0.00 |
Maximum of Months | 2395.64 | 1706.15 | 1850.01 | 934.84 | 976.42 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 12.62 | 2715.08 | 339.38 | 0.00 | 339.38 | 0.00 | 0.00 |
February | 97.78 | 1997.47 | 479.18 | 0.00 | 479.18 | 0.00 | 0.00 |
March | 318.90 | 1589.26 | 778.41 | 0.00 | 778.41 | 0.00 | 0.00 |
April | 534.75 | 1099.14 | 887.55 | 5.18 | 882.37 | 0.00 | 0.00 |
May | 930.86 | 842.06 | 1165.56 | 69.07 | 1096.50 | 0.00 | 0.00 |
June | 1422.65 | 550.15 | 1357.23 | 156.00 | 1201.23 | 0.00 | 0.00 |
July | 1523.02 | 465.00 | 1239.91 | 116.13 | 1123.78 | 0.00 | 0.00 |
August | 1110.30 | 534.53 | 993.55 | 26.63 | 966.91 | 0.00 | 0.00 |
September | 651.50 | 831.01 | 744.10 | 0.27 | 743.83 | 0.00 | 0.00 |
October | 255.24 | 1236.50 | 542.77 | 0.00 | 542.77 | 0.00 | 0.00 |
November | 64.45 | 1737.10 | 368.98 | 0.00 | 368.98 | 0.00 | 0.00 |
December | 7.74 | 2359.35 | 284.59 | 0.00 | 284.59 | 0.00 | 0.00 |
Annual Sum or Average | 580.43 | 1327.25 | 766.64 | 31.26 | 735.37 | 0.00 | 0.00 |
Minimum of Months | 7.74 | 465.00 | 284.59 | 0.00 | 284.59 | 0.00 | 0.00 |
Maximum of Months | 1523.02 | 2715.08 | 1357.23 | 156.00 | 1201.23 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 287.15 | 1674.67 | 519.54 | 238.19 | 281.35 | 0.00 | 0.00 |
February | 629.21 | 1237.74 | 812.60 | 403.44 | 409.17 | 0.00 | 0.00 |
March | 924.83 | 1017.77 | 1092.62 | 452.09 | 640.53 | 0.00 | 0.00 |
April | 1381.72 | 729.09 | 1394.08 | 690.89 | 703.18 | 0.00 | 0.00 |
May | 1621.91 | 584.45 | 1539.94 | 685.17 | 854.77 | 0.00 | 0.00 |
June | 2386.58 | 391.55 | 1993.25 | 1025.72 | 967.53 | 0.00 | 0.00 |
July | 2689.68 | 328.14 | 2091.97 | 1182.64 | 909.33 | 0.00 | 0.00 |
August | 2283.64 | 370.10 | 1818.02 | 1012.94 | 805.08 | 0.00 | 0.00 |
September | 1465.99 | 542.35 | 1286.07 | 663.86 | 622.21 | 0.00 | 0.00 |
October | 875.64 | 793.85 | 922.69 | 468.52 | 454.16 | 0.00 | 0.00 |
November | 410.62 | 1073.74 | 584.78 | 273.01 | 311.77 | 0.00 | 0.00 |
December | 223.85 | 1451.83 | 431.31 | 185.25 | 246.06 | 0.00 | 0.00 |
Annual Sum or Average | 1268.69 | 848.23 | 1209.31 | 607.86 | 601.44 | 0.00 | 0.00 |
Minimum of Months | 223.85 | 328.14 | 431.31 | 185.25 | 246.06 | 0.00 | 0.00 |
Maximum of Months | 2689.68 | 1674.67 | 2091.97 | 1182.64 | 967.53 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 2281.73 | 2336.13 | 2392.19 | 1708.55 | 683.64 | 0.00 | 0.00 |
February | 3182.77 | 1795.12 | 3046.42 | 2191.09 | 855.32 | 0.00 | 0.00 |
March | 2844.12 | 1594.95 | 2723.10 | 1529.16 | 1193.94 | 0.00 | 0.00 |
April | 2378.70 | 1169.67 | 2188.92 | 1046.97 | 1141.95 | 0.00 | 0.00 |
May | 2153.80 | 926.11 | 1944.81 | 645.92 | 1298.89 | 0.00 | 0.00 |
June | 2415.12 | 640.73 | 1932.36 | 563.56 | 1368.80 | 0.00 | 0.00 |
July | 2876.16 | 527.84 | 2083.28 | 769.55 | 1313.73 | 0.00 | 0.00 |
August | 3312.62 | 603.11 | 2475.84 | 1248.26 | 1227.57 | 0.00 | 0.00 |
September | 3404.09 | 882.81 | 2745.99 | 1682.55 | 1063.44 | 0.00 | 0.00 |
October | 3268.26 | 1252.71 | 2870.79 | 1985.11 | 885.68 | 0.00 | 0.00 |
November | 2730.10 | 1574.93 | 2617.30 | 1895.87 | 721.44 | 0.00 | 0.00 |
December | 2204.72 | 2035.87 | 2274.84 | 1642.66 | 632.18 | 0.00 | 0.00 |
Annual Sum or Average | 2751.07 | 1276.40 | 2437.12 | 1403.90 | 1033.21 | 0.00 | 0.00 |
Minimum of Months | 2153.80 | 527.84 | 1932.36 | 563.56 | 632.18 | 0.00 | 0.00 |
Maximum of Months | 3404.09 | 2336.13 | 3046.42 | 2191.09 | 1368.80 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 252.03 | 1739.87 | 470.59 | 189.65 | 280.94 | 0.00 | 0.00 |
February | 639.41 | 1271.91 | 803.23 | 394.83 | 408.40 | 0.00 | 0.00 |
March | 858.52 | 1058.74 | 1027.94 | 376.65 | 651.29 | 0.00 | 0.00 |
April | 1349.18 | 768.34 | 1341.98 | 594.56 | 747.42 | 0.00 | 0.00 |
May | 1801.24 | 624.20 | 1659.93 | 757.02 | 902.92 | 0.00 | 0.00 |
June | 2173.07 | 433.17 | 1805.95 | 829.54 | 976.41 | 0.00 | 0.00 |
July | 2404.26 | 368.57 | 1849.99 | 934.82 | 915.17 | 0.00 | 0.00 |
August | 1987.48 | 399.55 | 1570.89 | 770.96 | 799.93 | 0.00 | 0.00 |
September | 1466.45 | 579.19 | 1263.68 | 638.86 | 624.82 | 0.00 | 0.00 |
October | 882.35 | 833.43 | 903.19 | 448.74 | 454.44 | 0.00 | 0.00 |
November | 510.09 | 1115.61 | 639.37 | 317.18 | 322.19 | 0.00 | 0.00 |
December | 240.89 | 1495.88 | 429.77 | 181.39 | 248.38 | 0.00 | 0.00 |
Annual Sum or Average | 1216.71 | 889.40 | 1148.77 | 536.70 | 612.07 | 0.00 | 0.00 |
Minimum of Months | 240.89 | 368.57 | 429.77 | 181.39 | 248.38 | 0.00 | 0.00 |
Maximum of Months | 2404.26 | 1739.87 | 1849.99 | 934.82 | 976.41 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 11.51 | 2751.08 | 339.38 | 0.00 | 339.38 | 0.00 | 0.00 |
February | 87.08 | 2046.37 | 479.19 | 0.00 | 479.19 | 0.00 | 0.00 |
March | 286.63 | 1650.37 | 778.42 | 0.00 | 778.42 | 0.00 | 0.00 |
April | 481.73 | 1179.16 | 887.57 | 5.18 | 882.39 | 0.00 | 0.00 |
May | 874.57 | 888.81 | 1165.59 | 69.07 | 1096.52 | 0.00 | 0.00 |
June | 1384.46 | 575.04 | 1357.26 | 156.01 | 1201.26 | 0.00 | 0.00 |
July | 1498.71 | 481.80 | 1239.93 | 116.13 | 1123.80 | 0.00 | 0.00 |
August | 1092.08 | 550.36 | 993.57 | 26.63 | 966.93 | 0.00 | 0.00 |
September | 638.12 | 841.37 | 744.11 | 0.27 | 743.84 | 0.00 | 0.00 |
October | 250.38 | 1229.40 | 542.79 | 0.00 | 542.79 | 0.00 | 0.00 |
November | 62.16 | 1729.71 | 368.99 | 0.00 | 368.99 | 0.00 | 0.00 |
December | 6.86 | 2359.92 | 284.59 | 0.00 | 284.59 | 0.00 | 0.00 |
Annual Sum or Average | 559.11 | 1354.30 | 766.65 | 31.26 | 735.39 | 0.00 | 0.00 |
Minimum of Months | 6.86 | 481.80 | 284.59 | 0.00 | 284.59 | 0.00 | 0.00 |
Maximum of Months | 1498.71 | 2751.08 | 1357.26 | 156.01 | 1201.26 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 281.82 | 1687.57 | 519.55 | 238.19 | 281.36 | 0.00 | 0.00 |
February | 615.92 | 1254.74 | 812.62 | 403.44 | 409.17 | 0.00 | 0.00 |
March | 902.16 | 1036.47 | 1092.64 | 452.10 | 640.53 | 0.00 | 0.00 |
April | 1354.07 | 750.77 | 1394.10 | 690.90 | 703.19 | 0.00 | 0.00 |
May | 1598.26 | 594.82 | 1539.96 | 685.19 | 854.78 | 0.00 | 0.00 |
June | 2370.55 | 391.98 | 1993.28 | 1025.74 | 967.54 | 0.00 | 0.00 |
July | 2680.89 | 321.76 | 2092.00 | 1182.67 | 909.34 | 0.00 | 0.00 |
August | 2276.28 | 362.50 | 1818.05 | 1012.96 | 805.09 | 0.00 | 0.00 |
September | 1461.63 | 526.78 | 1286.09 | 663.87 | 622.21 | 0.00 | 0.00 |
October | 875.69 | 767.87 | 922.70 | 468.53 | 454.17 | 0.00 | 0.00 |
November | 410.00 | 1054.47 | 584.79 | 273.02 | 311.77 | 0.00 | 0.00 |
December | 221.43 | 1446.63 | 431.32 | 185.25 | 246.07 | 0.00 | 0.00 |
Annual Sum or Average | 1257.71 | 848.21 | 1209.33 | 607.87 | 601.45 | 0.00 | 0.00 |
Minimum of Months | 221.43 | 321.76 | 431.32 | 185.25 | 246.07 | 0.00 | 0.00 |
Maximum of Months | 2680.89 | 1687.57 | 2092.00 | 1182.67 | 967.54 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 2236.16 | 2378.16 | 2392.28 | 1708.62 | 683.67 | 0.00 | 0.00 |
February | 3125.97 | 1803.69 | 3046.54 | 2191.18 | 855.35 | 0.00 | 0.00 |
March | 2786.81 | 1614.95 | 2723.21 | 1529.23 | 1193.98 | 0.00 | 0.00 |
April | 2323.18 | 1212.51 | 2189.00 | 1047.01 | 1141.99 | 0.00 | 0.00 |
May | 2097.44 | 964.74 | 1944.87 | 645.95 | 1298.93 | 0.00 | 0.00 |
June | 2374.36 | 664.39 | 1932.43 | 563.59 | 1368.84 | 0.00 | 0.00 |
July | 2854.85 | 530.70 | 2083.35 | 769.58 | 1313.77 | 0.00 | 0.00 |
August | 3293.63 | 596.19 | 2475.92 | 1248.32 | 1227.61 | 0.00 | 0.00 |
September | 3385.34 | 852.21 | 2746.10 | 1682.62 | 1063.47 | 0.00 | 0.00 |
October | 3251.61 | 1193.66 | 2870.90 | 1985.19 | 885.71 | 0.00 | 0.00 |
November | 2709.90 | 1527.65 | 2617.41 | 1895.95 | 721.46 | 0.00 | 0.00 |
December | 2176.43 | 2035.71 | 2274.93 | 1642.73 | 632.20 | 0.00 | 0.00 |
Annual Sum or Average | 2714.84 | 1279.30 | 2437.21 | 1403.96 | 1033.24 | 0.00 | 0.00 |
Minimum of Months | 2097.44 | 530.70 | 1932.43 | 563.59 | 632.20 | 0.00 | 0.00 |
Maximum of Months | 3385.34 | 2378.16 | 3046.54 | 2191.18 | 1368.84 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 246.26 | 1758.24 | 470.60 | 189.65 | 280.94 | 0.00 | 0.00 |
February | 623.93 | 1290.77 | 803.24 | 394.83 | 408.41 | 0.00 | 0.00 |
March | 833.84 | 1083.62 | 1027.95 | 376.66 | 651.30 | 0.00 | 0.00 |
April | 1318.12 | 797.09 | 1342.00 | 594.57 | 747.43 | 0.00 | 0.00 |
May | 1776.46 | 634.62 | 1659.96 | 757.03 | 902.93 | 0.00 | 0.00 |
June | 2155.27 | 436.61 | 1805.97 | 829.55 | 976.42 | 0.00 | 0.00 |
July | 2394.74 | 364.18 | 1850.01 | 934.84 | 915.17 | 0.00 | 0.00 |
August | 1979.55 | 394.86 | 1570.91 | 770.97 | 799.94 | 0.00 | 0.00 |
September | 1461.38 | 565.67 | 1263.70 | 638.88 | 624.82 | 0.00 | 0.00 |
October | 881.13 | 810.36 | 903.20 | 448.75 | 454.45 | 0.00 | 0.00 |
November | 506.35 | 1098.35 | 639.38 | 317.19 | 322.19 | 0.00 | 0.00 |
December | 236.46 | 1491.62 | 429.78 | 181.40 | 248.38 | 0.00 | 0.00 |
Annual Sum or Average | 1204.12 | 892.43 | 1148.79 | 536.71 | 612.08 | 0.00 | 0.00 |
Minimum of Months | 236.46 | 364.18 | 429.78 | 181.40 | 248.38 | 0.00 | 0.00 |
Maximum of Months | 2394.74 | 1758.24 | 1850.01 | 934.84 | 976.42 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 40368865.92 | 0.714764E+10 | 0.909008E+09 | 0.00 | 0.909008E+09 | 0.00 | 0.00 |
February | 0.235977E+09 | 0.474897E+10 | 0.115926E+10 | 0.00 | 0.115926E+10 | 0.00 | 0.00 |
March | 0.814672E+09 | 0.420323E+10 | 0.208493E+10 | 0.00 | 0.208493E+10 | 0.00 | 0.00 |
April | 0.129722E+10 | 0.287605E+10 | 0.230057E+10 | 13425633.98 | 0.228715E+10 | 0.00 | 0.00 |
May | 0.238775E+10 | 0.225348E+10 | 0.312191E+10 | 0.184993E+09 | 0.293692E+10 | 0.00 | 0.00 |
June | 0.360959E+10 | 0.143707E+10 | 0.351802E+10 | 0.404367E+09 | 0.311366E+10 | 0.00 | 0.00 |
July | 0.402297E+10 | 0.125152E+10 | 0.332104E+10 | 0.311055E+09 | 0.300998E+10 | 0.00 | 0.00 |
August | 0.293987E+10 | 0.141330E+10 | 0.266116E+10 | 71331635.12 | 0.258983E+10 | 0.00 | 0.00 |
September | 0.168704E+10 | 0.205131E+10 | 0.192874E+10 | 692135.30 | 0.192804E+10 | 0.00 | 0.00 |
October | 0.732391E+09 | 0.305467E+10 | 0.145380E+10 | 0.00 | 0.145380E+10 | 0.00 | 0.00 |
November | 0.189478E+09 | 0.419591E+10 | 0.956425E+09 | 0.00 | 0.956425E+09 | 0.00 | 0.00 |
December | 22197141.10 | 0.605430E+10 | 0.762255E+09 | 0.00 | 0.762255E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.179795E+11 | 0.406875E+11 | 0.241771E+11 | 0.985864E+09 | 0.231913E+11 | 0.00 | 0.00 |
Minimum of Months | 22197141.10 | 0.125152E+10 | 0.762255E+09 | 0.00 | 0.762255E+09 | 0.00 | 0.00 |
Maximum of Months | 0.402297E+10 | 0.714764E+10 | 0.351802E+10 | 0.404367E+09 | 0.311366E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.772987E+09 | 0.438553E+10 | 0.139155E+10 | 0.637971E+09 | 0.753582E+09 | 0.00 | 0.00 |
February | 0.151961E+10 | 0.291546E+10 | 0.196588E+10 | 0.976014E+09 | 0.989869E+09 | 0.00 | 0.00 |
March | 0.245262E+10 | 0.264704E+10 | 0.292652E+10 | 0.121091E+10 | 0.171561E+10 | 0.00 | 0.00 |
April | 0.353965E+10 | 0.184507E+10 | 0.361350E+10 | 0.179082E+10 | 0.182268E+10 | 0.00 | 0.00 |
May | 0.430173E+10 | 0.151616E+10 | 0.412464E+10 | 0.183520E+10 | 0.228943E+10 | 0.00 | 0.00 |
June | 0.614956E+10 | 0.983379E+09 | 0.516659E+10 | 0.265872E+10 | 0.250786E+10 | 0.00 | 0.00 |
July | 0.717849E+10 | 0.836921E+09 | 0.560323E+10 | 0.316765E+10 | 0.243557E+10 | 0.00 | 0.00 |
August | 0.609958E+10 | 0.935574E+09 | 0.486945E+10 | 0.271311E+10 | 0.215634E+10 | 0.00 | 0.00 |
September | 0.380742E+10 | 0.129659E+10 | 0.333354E+10 | 0.172076E+10 | 0.161278E+10 | 0.00 | 0.00 |
October | 0.239040E+10 | 0.192383E+10 | 0.247136E+10 | 0.125492E+10 | 0.121644E+10 | 0.00 | 0.00 |
November | 0.110257E+10 | 0.256986E+10 | 0.151578E+10 | 0.707668E+09 | 0.808108E+09 | 0.00 | 0.00 |
December | 0.613017E+09 | 0.371353E+10 | 0.115524E+10 | 0.496178E+09 | 0.659061E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.399276E+11 | 0.255689E+11 | 0.381373E+11 | 0.191699E+11 | 0.189673E+11 | 0.00 | 0.00 |
Minimum of Months | 0.613017E+09 | 0.836921E+09 | 0.115524E+10 | 0.496178E+09 | 0.659061E+09 | 0.00 | 0.00 |
Maximum of Months | 0.717849E+10 | 0.438553E+10 | 0.560323E+10 | 0.316765E+10 | 0.250786E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.603104E+10 | 0.615941E+10 | 0.640749E+10 | 0.457636E+10 | 0.183113E+10 | 0.00 | 0.00 |
February | 0.760841E+10 | 0.417575E+10 | 0.737018E+10 | 0.530091E+10 | 0.206927E+10 | 0.00 | 0.00 |
March | 0.751141E+10 | 0.411496E+10 | 0.729384E+10 | 0.409588E+10 | 0.319795E+10 | 0.00 | 0.00 |
April | 0.606000E+10 | 0.297125E+10 | 0.567389E+10 | 0.271386E+10 | 0.296003E+10 | 0.00 | 0.00 |
May | 0.564593E+10 | 0.244911E+10 | 0.520915E+10 | 0.173010E+10 | 0.347905E+10 | 0.00 | 0.00 |
June | 0.616192E+10 | 0.165227E+10 | 0.500885E+10 | 0.146082E+10 | 0.354803E+10 | 0.00 | 0.00 |
July | 0.764588E+10 | 0.136992E+10 | 0.558004E+10 | 0.206125E+10 | 0.351879E+10 | 0.00 | 0.00 |
August | 0.882396E+10 | 0.152855E+10 | 0.663152E+10 | 0.334349E+10 | 0.328803E+10 | 0.00 | 0.00 |
September | 0.879459E+10 | 0.208862E+10 | 0.711789E+10 | 0.436136E+10 | 0.275653E+10 | 0.00 | 0.00 |
October | 0.876351E+10 | 0.298730E+10 | 0.768941E+10 | 0.531713E+10 | 0.237228E+10 | 0.00 | 0.00 |
November | 0.709856E+10 | 0.371864E+10 | 0.678432E+10 | 0.491429E+10 | 0.187003E+10 | 0.00 | 0.00 |
December | 0.588944E+10 | 0.520820E+10 | 0.609317E+10 | 0.439988E+10 | 0.169328E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.860347E+11 | 0.384240E+11 | 0.768598E+11 | 0.442753E+11 | 0.325844E+11 | 0.00 | 0.00 |
Minimum of Months | 0.564593E+10 | 0.136992E+10 | 0.500885E+10 | 0.146082E+10 | 0.169328E+10 | 0.00 | 0.00 |
Maximum of Months | 0.882396E+10 | 0.615941E+10 | 0.768941E+10 | 0.531713E+10 | 0.354803E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.670377E+09 | 0.456974E+10 | 0.126045E+10 | 0.507971E+09 | 0.752480E+09 | 0.00 | 0.00 |
February | 0.152915E+10 | 0.299366E+10 | 0.194320E+10 | 0.955182E+09 | 0.988019E+09 | 0.00 | 0.00 |
March | 0.225946E+10 | 0.276453E+10 | 0.275327E+10 | 0.100884E+10 | 0.174443E+10 | 0.00 | 0.00 |
April | 0.344471E+10 | 0.195505E+10 | 0.347846E+10 | 0.154112E+10 | 0.193734E+10 | 0.00 | 0.00 |
May | 0.477844E+10 | 0.161272E+10 | 0.444603E+10 | 0.202763E+10 | 0.241840E+10 | 0.00 | 0.00 |
June | 0.559403E+10 | 0.108676E+10 | 0.468107E+10 | 0.215019E+10 | 0.253088E+10 | 0.00 | 0.00 |
July | 0.641649E+10 | 0.941649E+09 | 0.495508E+10 | 0.250387E+10 | 0.245120E+10 | 0.00 | 0.00 |
August | 0.530977E+10 | 0.101247E+10 | 0.420753E+10 | 0.206497E+10 | 0.214256E+10 | 0.00 | 0.00 |
September | 0.380797E+10 | 0.138381E+10 | 0.327551E+10 | 0.165596E+10 | 0.161954E+10 | 0.00 | 0.00 |
October | 0.239795E+10 | 0.202331E+10 | 0.241913E+10 | 0.120193E+10 | 0.121719E+10 | 0.00 | 0.00 |
November | 0.134125E+10 | 0.267353E+10 | 0.165727E+10 | 0.822147E+09 | 0.835122E+09 | 0.00 | 0.00 |
December | 0.647493E+09 | 0.382892E+10 | 0.115112E+10 | 0.485855E+09 | 0.665265E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.381971E+11 | 0.268462E+11 | 0.362281E+11 | 0.169257E+11 | 0.193024E+11 | 0.00 | 0.00 |
Minimum of Months | 0.647493E+09 | 0.941649E+09 | 0.115112E+10 | 0.485855E+09 | 0.665265E+09 | 0.00 | 0.00 |
Maximum of Months | 0.641649E+10 | 0.456974E+10 | 0.495508E+10 | 0.250387E+10 | 0.253088E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 33792935.58 | 0.727207E+10 | 0.908988E+09 | 0.00 | 0.908988E+09 | 0.00 | 0.00 |
February | 0.236547E+09 | 0.483228E+10 | 0.115923E+10 | 0.00 | 0.115923E+10 | 0.00 | 0.00 |
March | 0.854146E+09 | 0.425667E+10 | 0.208488E+10 | 0.00 | 0.208488E+10 | 0.00 | 0.00 |
April | 0.138607E+10 | 0.284896E+10 | 0.230053E+10 | 13425239.37 | 0.228710E+10 | 0.00 | 0.00 |
May | 0.249322E+10 | 0.225536E+10 | 0.312184E+10 | 0.184987E+09 | 0.293686E+10 | 0.00 | 0.00 |
June | 0.368752E+10 | 0.142598E+10 | 0.351795E+10 | 0.404355E+09 | 0.311360E+10 | 0.00 | 0.00 |
July | 0.407925E+10 | 0.124545E+10 | 0.332097E+10 | 0.311046E+09 | 0.300993E+10 | 0.00 | 0.00 |
August | 0.297382E+10 | 0.143168E+10 | 0.266111E+10 | 71329538.49 | 0.258978E+10 | 0.00 | 0.00 |
September | 0.168868E+10 | 0.215399E+10 | 0.192870E+10 | 692114.96 | 0.192801E+10 | 0.00 | 0.00 |
October | 0.683637E+09 | 0.331184E+10 | 0.145377E+10 | 0.00 | 0.145377E+10 | 0.00 | 0.00 |
November | 0.167046E+09 | 0.450256E+10 | 0.956405E+09 | 0.00 | 0.956405E+09 | 0.00 | 0.00 |
December | 20742596.48 | 0.631928E+10 | 0.762238E+09 | 0.00 | 0.762238E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.183045E+11 | 0.418561E+11 | 0.241766E+11 | 0.985835E+09 | 0.231908E+11 | 0.00 | 0.00 |
Minimum of Months | 20742596.48 | 0.124545E+10 | 0.762238E+09 | 0.00 | 0.762238E+09 | 0.00 | 0.00 |
Maximum of Months | 0.407925E+10 | 0.727207E+10 | 0.351795E+10 | 0.404355E+09 | 0.311360E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.769098E+09 | 0.448545E+10 | 0.139153E+10 | 0.637958E+09 | 0.753572E+09 | 0.00 | 0.00 |
February | 0.152218E+10 | 0.299433E+10 | 0.196585E+10 | 0.975995E+09 | 0.989856E+09 | 0.00 | 0.00 |
March | 0.247706E+10 | 0.272598E+10 | 0.292647E+10 | 0.121089E+10 | 0.171558E+10 | 0.00 | 0.00 |
April | 0.358142E+10 | 0.188979E+10 | 0.361344E+10 | 0.179079E+10 | 0.182265E+10 | 0.00 | 0.00 |
May | 0.434413E+10 | 0.156539E+10 | 0.412457E+10 | 0.183517E+10 | 0.228940E+10 | 0.00 | 0.00 |
June | 0.618600E+10 | 0.101489E+10 | 0.516650E+10 | 0.265867E+10 | 0.250783E+10 | 0.00 | 0.00 |
July | 0.720404E+10 | 0.878884E+09 | 0.560314E+10 | 0.316759E+10 | 0.243555E+10 | 0.00 | 0.00 |
August | 0.611650E+10 | 0.991278E+09 | 0.486938E+10 | 0.271306E+10 | 0.215632E+10 | 0.00 | 0.00 |
September | 0.379986E+10 | 0.140576E+10 | 0.333349E+10 | 0.172073E+10 | 0.161276E+10 | 0.00 | 0.00 |
October | 0.234531E+10 | 0.212625E+10 | 0.247132E+10 | 0.125490E+10 | 0.121643E+10 | 0.00 | 0.00 |
November | 0.106432E+10 | 0.278314E+10 | 0.151575E+10 | 0.707654E+09 | 0.808097E+09 | 0.00 | 0.00 |
December | 0.599556E+09 | 0.388858E+10 | 0.115522E+10 | 0.496168E+09 | 0.659052E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.400095E+11 | 0.267497E+11 | 0.381367E+11 | 0.191696E+11 | 0.189671E+11 | 0.00 | 0.00 |
Minimum of Months | 0.599556E+09 | 0.878884E+09 | 0.115522E+10 | 0.496168E+09 | 0.659052E+09 | 0.00 | 0.00 |
Maximum of Months | 0.720404E+10 | 0.448545E+10 | 0.560314E+10 | 0.316759E+10 | 0.250783E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.611138E+10 | 0.625708E+10 | 0.640724E+10 | 0.457617E+10 | 0.183107E+10 | 0.00 | 0.00 |
February | 0.769975E+10 | 0.434274E+10 | 0.736989E+10 | 0.530069E+10 | 0.206920E+10 | 0.00 | 0.00 |
March | 0.761769E+10 | 0.427190E+10 | 0.729356E+10 | 0.409571E+10 | 0.319785E+10 | 0.00 | 0.00 |
April | 0.616559E+10 | 0.303178E+10 | 0.567369E+10 | 0.271375E+10 | 0.295994E+10 | 0.00 | 0.00 |
May | 0.576873E+10 | 0.248050E+10 | 0.520897E+10 | 0.173003E+10 | 0.347894E+10 | 0.00 | 0.00 |
June | 0.626000E+10 | 0.166078E+10 | 0.500869E+10 | 0.146076E+10 | 0.354793E+10 | 0.00 | 0.00 |
July | 0.770350E+10 | 0.141376E+10 | 0.557986E+10 | 0.206117E+10 | 0.351869E+10 | 0.00 | 0.00 |
August | 0.887253E+10 | 0.161538E+10 | 0.663128E+10 | 0.334335E+10 | 0.328793E+10 | 0.00 | 0.00 |
September | 0.882341E+10 | 0.228825E+10 | 0.711762E+10 | 0.436118E+10 | 0.275644E+10 | 0.00 | 0.00 |
October | 0.875370E+10 | 0.335526E+10 | 0.768911E+10 | 0.531691E+10 | 0.237220E+10 | 0.00 | 0.00 |
November | 0.707642E+10 | 0.408223E+10 | 0.678405E+10 | 0.491409E+10 | 0.186997E+10 | 0.00 | 0.00 |
December | 0.590511E+10 | 0.545288E+10 | 0.609292E+10 | 0.439970E+10 | 0.169322E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.867578E+11 | 0.402526E+11 | 0.768569E+11 | 0.442735E+11 | 0.325834E+11 | 0.00 | 0.00 |
Minimum of Months | 0.576873E+10 | 0.141376E+10 | 0.500869E+10 | 0.146076E+10 | 0.169322E+10 | 0.00 | 0.00 |
Maximum of Months | 0.887253E+10 | 0.625708E+10 | 0.768911E+10 | 0.531691E+10 | 0.354793E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.675041E+09 | 0.466006E+10 | 0.126043E+10 | 0.507963E+09 | 0.752472E+09 | 0.00 | 0.00 |
February | 0.154686E+10 | 0.307701E+10 | 0.194317E+10 | 0.955166E+09 | 0.988008E+09 | 0.00 | 0.00 |
March | 0.229945E+10 | 0.283573E+10 | 0.275323E+10 | 0.100882E+10 | 0.174441E+10 | 0.00 | 0.00 |
April | 0.349708E+10 | 0.199153E+10 | 0.347841E+10 | 0.154109E+10 | 0.193732E+10 | 0.00 | 0.00 |
May | 0.482445E+10 | 0.167185E+10 | 0.444597E+10 | 0.202759E+10 | 0.241838E+10 | 0.00 | 0.00 |
June | 0.563261E+10 | 0.112278E+10 | 0.468101E+10 | 0.215016E+10 | 0.253085E+10 | 0.00 | 0.00 |
July | 0.643958E+10 | 0.987172E+09 | 0.495501E+10 | 0.250383E+10 | 0.245118E+10 | 0.00 | 0.00 |
August | 0.532328E+10 | 0.107016E+10 | 0.420747E+10 | 0.206493E+10 | 0.214254E+10 | 0.00 | 0.00 |
September | 0.380103E+10 | 0.150127E+10 | 0.327547E+10 | 0.165594E+10 | 0.161953E+10 | 0.00 | 0.00 |
October | 0.236328E+10 | 0.223225E+10 | 0.241909E+10 | 0.120191E+10 | 0.121718E+10 | 0.00 | 0.00 |
November | 0.132216E+10 | 0.289165E+10 | 0.165725E+10 | 0.822133E+09 | 0.835113E+09 | 0.00 | 0.00 |
December | 0.645213E+09 | 0.400656E+10 | 0.115110E+10 | 0.485847E+09 | 0.665257E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.383700E+11 | 0.280480E+11 | 0.362276E+11 | 0.169254E+11 | 0.193022E+11 | 0.00 | 0.00 |
Minimum of Months | 0.645213E+09 | 0.987172E+09 | 0.115110E+10 | 0.485847E+09 | 0.665257E+09 | 0.00 | 0.00 |
Maximum of Months | 0.643958E+10 | 0.466006E+10 | 0.495501E+10 | 0.250383E+10 | 0.253085E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 30841200.46 | 0.736849E+10 | 0.909008E+09 | 0.00 | 0.909008E+09 | 0.00 | 0.00 |
February | 0.210674E+09 | 0.495058E+10 | 0.115926E+10 | 0.00 | 0.115926E+10 | 0.00 | 0.00 |
March | 0.767705E+09 | 0.442035E+10 | 0.208493E+10 | 0.00 | 0.208493E+10 | 0.00 | 0.00 |
April | 0.124865E+10 | 0.305639E+10 | 0.230057E+10 | 13425633.98 | 0.228715E+10 | 0.00 | 0.00 |
May | 0.234244E+10 | 0.238058E+10 | 0.312191E+10 | 0.184993E+09 | 0.293692E+10 | 0.00 | 0.00 |
June | 0.358852E+10 | 0.149050E+10 | 0.351802E+10 | 0.404367E+09 | 0.311366E+10 | 0.00 | 0.00 |
July | 0.401413E+10 | 0.129045E+10 | 0.332104E+10 | 0.311055E+09 | 0.300998E+10 | 0.00 | 0.00 |
August | 0.292503E+10 | 0.147408E+10 | 0.266116E+10 | 71331635.12 | 0.258983E+10 | 0.00 | 0.00 |
September | 0.165401E+10 | 0.218084E+10 | 0.192874E+10 | 692135.30 | 0.192804E+10 | 0.00 | 0.00 |
October | 0.670622E+09 | 0.329281E+10 | 0.145380E+10 | 0.00 | 0.145380E+10 | 0.00 | 0.00 |
November | 0.161112E+09 | 0.448342E+10 | 0.956425E+09 | 0.00 | 0.956425E+09 | 0.00 | 0.00 |
December | 18372698.75 | 0.632082E+10 | 0.762255E+09 | 0.00 | 0.762255E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.176321E+11 | 0.427093E+11 | 0.241771E+11 | 0.985864E+09 | 0.231913E+11 | 0.00 | 0.00 |
Minimum of Months | 18372698.75 | 0.129045E+10 | 0.762255E+09 | 0.00 | 0.762255E+09 | 0.00 | 0.00 |
Maximum of Months | 0.401413E+10 | 0.736849E+10 | 0.351802E+10 | 0.404367E+09 | 0.311366E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.754837E+09 | 0.451998E+10 | 0.139155E+10 | 0.637971E+09 | 0.753582E+09 | 0.00 | 0.00 |
February | 0.149002E+10 | 0.303546E+10 | 0.196588E+10 | 0.976014E+09 | 0.989869E+09 | 0.00 | 0.00 |
March | 0.241634E+10 | 0.277608E+10 | 0.292652E+10 | 0.121091E+10 | 0.171561E+10 | 0.00 | 0.00 |
April | 0.350975E+10 | 0.194598E+10 | 0.361350E+10 | 0.179082E+10 | 0.182268E+10 | 0.00 | 0.00 |
May | 0.428079E+10 | 0.159316E+10 | 0.412464E+10 | 0.183520E+10 | 0.228943E+10 | 0.00 | 0.00 |
June | 0.614445E+10 | 0.101601E+10 | 0.516659E+10 | 0.265872E+10 | 0.250786E+10 | 0.00 | 0.00 |
July | 0.718048E+10 | 0.861790E+09 | 0.560323E+10 | 0.316765E+10 | 0.243557E+10 | 0.00 | 0.00 |
August | 0.609679E+10 | 0.970913E+09 | 0.486945E+10 | 0.271311E+10 | 0.215634E+10 | 0.00 | 0.00 |
September | 0.378855E+10 | 0.136542E+10 | 0.333354E+10 | 0.172076E+10 | 0.161278E+10 | 0.00 | 0.00 |
October | 0.234545E+10 | 0.205667E+10 | 0.247136E+10 | 0.125492E+10 | 0.121644E+10 | 0.00 | 0.00 |
November | 0.106271E+10 | 0.273319E+10 | 0.151578E+10 | 0.707668E+09 | 0.808108E+09 | 0.00 | 0.00 |
December | 0.593075E+09 | 0.387464E+10 | 0.115524E+10 | 0.496178E+09 | 0.659061E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.396632E+11 | 0.267493E+11 | 0.381373E+11 | 0.191699E+11 | 0.189673E+11 | 0.00 | 0.00 |
Minimum of Months | 0.593075E+09 | 0.861790E+09 | 0.115524E+10 | 0.496178E+09 | 0.659061E+09 | 0.00 | 0.00 |
Maximum of Months | 0.718048E+10 | 0.451998E+10 | 0.560323E+10 | 0.316765E+10 | 0.250786E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.598932E+10 | 0.636967E+10 | 0.640749E+10 | 0.457636E+10 | 0.183113E+10 | 0.00 | 0.00 |
February | 0.756235E+10 | 0.436350E+10 | 0.737018E+10 | 0.530091E+10 | 0.206927E+10 | 0.00 | 0.00 |
March | 0.746419E+10 | 0.432547E+10 | 0.729384E+10 | 0.409588E+10 | 0.319795E+10 | 0.00 | 0.00 |
April | 0.602169E+10 | 0.314282E+10 | 0.567389E+10 | 0.271386E+10 | 0.296003E+10 | 0.00 | 0.00 |
May | 0.561779E+10 | 0.258396E+10 | 0.520915E+10 | 0.173010E+10 | 0.347905E+10 | 0.00 | 0.00 |
June | 0.615434E+10 | 0.172209E+10 | 0.500885E+10 | 0.146082E+10 | 0.354803E+10 | 0.00 | 0.00 |
July | 0.764643E+10 | 0.142144E+10 | 0.558004E+10 | 0.206125E+10 | 0.351879E+10 | 0.00 | 0.00 |
August | 0.882166E+10 | 0.159684E+10 | 0.663152E+10 | 0.334349E+10 | 0.328803E+10 | 0.00 | 0.00 |
September | 0.877480E+10 | 0.220892E+10 | 0.711789E+10 | 0.436136E+10 | 0.275653E+10 | 0.00 | 0.00 |
October | 0.870912E+10 | 0.319711E+10 | 0.768941E+10 | 0.531713E+10 | 0.237228E+10 | 0.00 | 0.00 |
November | 0.702406E+10 | 0.395966E+10 | 0.678432E+10 | 0.491429E+10 | 0.187003E+10 | 0.00 | 0.00 |
December | 0.582935E+10 | 0.545245E+10 | 0.609317E+10 | 0.439988E+10 | 0.169328E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.856151E+11 | 0.403439E+11 | 0.768598E+11 | 0.442753E+11 | 0.325844E+11 | 0.00 | 0.00 |
Minimum of Months | 0.561779E+10 | 0.142144E+10 | 0.500885E+10 | 0.146082E+10 | 0.169328E+10 | 0.00 | 0.00 |
Maximum of Months | 0.882166E+10 | 0.636967E+10 | 0.768941E+10 | 0.531713E+10 | 0.354803E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.659586E+09 | 0.470928E+10 | 0.126045E+10 | 0.507971E+09 | 0.752480E+09 | 0.00 | 0.00 |
February | 0.150942E+10 | 0.312263E+10 | 0.194320E+10 | 0.955182E+09 | 0.988019E+09 | 0.00 | 0.00 |
March | 0.223335E+10 | 0.290236E+10 | 0.275327E+10 | 0.100884E+10 | 0.174443E+10 | 0.00 | 0.00 |
April | 0.341657E+10 | 0.206605E+10 | 0.347846E+10 | 0.154112E+10 | 0.193734E+10 | 0.00 | 0.00 |
May | 0.475807E+10 | 0.169977E+10 | 0.444603E+10 | 0.202763E+10 | 0.241840E+10 | 0.00 | 0.00 |
June | 0.558647E+10 | 0.113170E+10 | 0.468107E+10 | 0.215019E+10 | 0.253088E+10 | 0.00 | 0.00 |
July | 0.641406E+10 | 0.975422E+09 | 0.495508E+10 | 0.250387E+10 | 0.245120E+10 | 0.00 | 0.00 |
August | 0.530203E+10 | 0.105759E+10 | 0.420753E+10 | 0.206497E+10 | 0.214256E+10 | 0.00 | 0.00 |
September | 0.378790E+10 | 0.146623E+10 | 0.327551E+10 | 0.165596E+10 | 0.161954E+10 | 0.00 | 0.00 |
October | 0.236002E+10 | 0.217047E+10 | 0.241913E+10 | 0.120193E+10 | 0.121719E+10 | 0.00 | 0.00 |
November | 0.131246E+10 | 0.284693E+10 | 0.165727E+10 | 0.822147E+09 | 0.835122E+09 | 0.00 | 0.00 |
December | 0.633330E+09 | 0.399516E+10 | 0.115112E+10 | 0.485855E+09 | 0.665265E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.379733E+11 | 0.281436E+11 | 0.362281E+11 | 0.169257E+11 | 0.193024E+11 | 0.00 | 0.00 |
Minimum of Months | 0.633330E+09 | 0.975422E+09 | 0.115112E+10 | 0.485855E+09 | 0.665265E+09 | 0.00 | 0.00 |
Maximum of Months | 0.641406E+10 | 0.470928E+10 | 0.495508E+10 | 0.250387E+10 | 0.253088E+10 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | -8.8 | -10.9 | -16.1 | 5.70 | -23.3 | 32.48 | 106.19 | 0.00 |
February | -2.2 | -5.0 | -9.9 | 6.21 | -16.1 | 41.31 | 158.25 | 0.00 |
March | 0.30 | -2.9 | -8.4 | 5.38 | -12.8 | 78.62 | 145.02 | 0.00 |
April | 6.67 | 2.34 | -2.9 | 4.89 | -6.2 | 82.10 | 182.32 | 0.01 |
May | 10.10 | 5.18 | 0.22 | 5.28 | -1.1 | 102.67 | 205.47 | 0.01 |
June | 16.46 | 10.06 | 4.91 | 4.56 | 5.05 | 103.05 | 264.47 | 0.02 |
July | 20.57 | 12.46 | 6.56 | 4.24 | 8.00 | 89.47 | 301.47 | 0.00 |
August | 19.17 | 11.04 | 4.61 | 4.29 | 7.19 | 78.96 | 261.05 | 0.00 |
September | 14.69 | 9.08 | 4.37 | 5.43 | 3.42 | 63.03 | 204.21 | 0.00 |
October | 8.64 | 4.13 | -1.0 | 5.38 | -4.2 | 47.64 | 162.42 | 0.00 |
November | 2.84 | -0.9 | -6.9 | 5.91 | -11.0 | 33.00 | 125.52 | 0.00 |
December | -4.1 | -6.5 | -11.1 | 5.64 | -18.2 | 26.54 | 97.81 | 0.00 |
Annual Sum or Average | 7.07 | 2.37 | -2.9 | 5.23 | -5.7 | 65.04 | 184.63 | 0.00 |
Minimum of Months | -8.8 | -10.9 | -16.1 | 4.24 | -23.3 | 26.54 | 97.81 | 0.00 |
Maximum of Months | 20.57 | 12.46 | 6.56 | 6.21 | 8.00 | 103.05 | 301.47 | 0.02 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 10.60 | 14-JAN-12:00 | 5.16 | -1.1 | 8.20 | -2.3 | 105.00 | 464.50 |
February | 18.90 | 27-FEB-14:00 | 7.23 | -7.8 | 5.20 | 1.37 | 76.00 | 634.50 |
March | 15.00 | 14-MAR-13:20 | 6.67 | -2.4 | 9.30 | 1.23 | 201.67 | 711.67 |
April | 23.30 | 07-APR-13:00 | 9.68 | -4.4 | 9.30 | 4.92 | 314.50 | 110.00 |
May | 30.00 | 20-MAY-15:00 | 15.22 | 5.60 | 6.70 | 20.57 | 215.50 | 18.50 |
June | 32.20 | 29-JUN-12:00 | 14.40 | 0.60 | 9.30 | 17.03 | 187.00 | 729.00 |
July | 37.20 | 17-JUL-15:00 | 17.28 | 4.40 | 4.60 | 20.22 | 119.50 | 797.00 |
August | 35.60 | 05-AUG-15:00 | 17.65 | 6.70 | 5.20 | 22.47 | 136.50 | 625.50 |
September | 34.40 | 02-SEP-14:00 | 16.28 | 4.40 | 7.70 | 20.75 | 95.50 | 789.50 |
October | 25.00 | 18-OCT-13:00 | 11.40 | -1.1 | 7.70 | 7.35 | 48.00 | 913.00 |
November | 17.20 | 04-NOV-13:00 | 8.18 | -1.1 | 11.30 | 2.22 | 81.00 | 689.50 |
December | 13.90 | 10-DEC-01:00 | 5.50 | -5.0 | 13.90 | 5.74 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 10.60 | 5.16 | -7.8 | 4.60 | -2.3 | 0.00 | 0.00 | |
Maximum of Months | 37.20 | 17.65 | 6.70 | 13.90 | 22.47 | 314.50 | 913.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -33.9 | 10-JAN-21:00 | -34.1 | -37.8 | 3.10 | -54.3 | 0.00 | 0.00 |
February | -25.0 | 01-FEB-03:00 | -25.2 | -27.8 | 2.10 | -45.6 | 0.00 | 0.00 |
March | -23.3 | 04-MAR-23:00 | -23.8 | -28.9 | 3.60 | -44.5 | 0.00 | 0.00 |
April | -7.8 | 29-APR-03:00 | -8.7 | -10.6 | 4.10 | -25.6 | 0.00 | 0.00 |
May | -2.8 | 08-MAY-00:10 | -3.3 | -3.9 | 6.18 | -10.2 | 0.00 | 0.00 |
June | 0.60 | 15-JUN-03:00 | -0.5 | -1.7 | 2.60 | -15.7 | 0.00 | 0.00 |
July | 5.60 | 08-JUL-03:00 | 2.99 | 0.00 | 4.10 | -9.2 | 0.00 | 0.00 |
August | 6.70 | 17-AUG-00:00 | 4.32 | 1.70 | 2.60 | -7.1 | 0.00 | 0.00 |
September | 0.00 | 17-SEP-02:00 | -1.6 | -3.9 | 4.10 | -16.8 | 0.00 | 0.00 |
October | -6.1 | 10-OCT-05:19 | -6.6 | -7.8 | 3.77 | -20.6 | 0.00 | 0.00 |
November | -16.7 | 26-NOV-07:00 | -17.3 | -20.6 | 4.60 | -33.8 | 19.50 | 94.00 |
December | -28.3 | 29-DEC-08:00 | -28.6 | -32.2 | 2.10 | -48.7 | 69.50 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -33.9 | -34.1 | -37.8 | 2.10 | -54.3 | 0.00 | 0.00 | |
Maximum of Months | 6.70 | 4.32 | 1.70 | 6.18 | -7.1 | 69.50 | 94.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 5.18 | 13-JAN-14:00 | 10.00 | 0.00 | 8.80 | -3.0 | 40.00 | 694.00 |
February | 7.23 | 27-FEB-14:00 | 18.90 | -7.8 | 5.20 | 1.37 | 76.00 | 634.50 |
March | 6.94 | 14-MAR-13:00 | 15.00 | -1.7 | 10.30 | 1.80 | 241.00 | 538.00 |
April | 11.02 | 06-APR-15:00 | 22.20 | 1.10 | 3.60 | 5.33 | 110.00 | 779.00 |
May | 15.22 | 20-MAY-15:00 | 30.00 | 5.60 | 6.70 | 20.57 | 215.50 | 18.50 |
June | 19.20 | 20-JUN-14:00 | 29.40 | 14.40 | 2.60 | 18.28 | 204.00 | 614.00 |
July | 19.21 | 19-JUL-11:00 | 29.40 | 14.40 | 8.80 | 19.52 | 306.50 | 563.50 |
August | 17.65 | 05-AUG-15:00 | 35.60 | 6.70 | 5.20 | 22.47 | 136.50 | 625.50 |
September | 20.12 | 07-SEP-15:20 | 25.17 | 17.93 | 4.10 | 15.88 | 127.67 | 652.00 |
October | 11.61 | 18-OCT-14:00 | 25.00 | -0.6 | 7.70 | 7.55 | 40.50 | 852.00 |
November | 8.89 | 17-NOV-16:00 | 17.20 | 1.10 | 11.30 | 4.10 | 0.00 | 0.00 |
December | 7.62 | 19-DEC-14:00 | 12.80 | 2.80 | 8.20 | 1.37 | 74.00 | 138.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 5.18 | 10.00 | -7.8 | 2.60 | -3.0 | 0.00 | 0.00 | |
Maximum of Months | 20.12 | 35.60 | 17.93 | 11.30 | 22.47 | 306.50 | 852.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 1.70 | 12-JAN-14:00 | 7.20 | 4.48 | 5.20 | -1.0 | 107.00 | 61.00 |
February | -0.6 | 11-FEB-08:00 | 4.40 | 2.16 | 10.80 | -5.7 | 69.50 | 50.50 |
March | -0.6 | 10-MAR-12:00 | 8.90 | 4.51 | 10.30 | -2.3 | 253.00 | 140.50 |
April | 6.10 | 17-APR-16:19 | 7.97 | 6.96 | 4.50 | 0.87 | 201.50 | 117.50 |
May | 12.20 | 02-MAY-12:00 | 18.90 | 14.61 | 12.90 | 14.84 | 108.50 | 934.50 |
June | 15.60 | 20-JUN-19:00 | 25.60 | 18.76 | 3.60 | 20.22 | 17.50 | 17.00 |
July | 16.70 | 18-JUL-21:00 | 19.40 | 17.51 | 4.10 | 16.49 | 0.00 | 0.00 |
August | 11.10 | 08-AUG-11:00 | 26.70 | 16.75 | 2.60 | 12.03 | 134.50 | 869.00 |
September | 18.30 | 07-SEP-14:00 | 24.40 | 20.10 | 4.10 | 15.57 | 111.00 | 720.00 |
October | 6.70 | 01-OCT-14:09 | 9.08 | 7.78 | 2.10 | 4.07 | 260.33 | 0.33 |
November | 3.30 | 16-NOV-19:00 | 10.60 | 6.88 | 9.80 | -1.7 | 0.00 | 0.00 |
December | 2.80 | 19-DEC-14:09 | 10.97 | 6.81 | 10.78 | -1.0 | 95.00 | 292.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -0.6 | 4.40 | 2.16 | 2.10 | -5.7 | 0.00 | 0.00 | |
Maximum of Months | 18.30 | 26.70 | 20.10 | 12.90 | 20.22 | 260.33 | 934.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 5.41 | 12.59 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 4.46 | 20.37 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 5.03 | 30.19 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 7.01 | 37.07 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 9.90 | 46.35 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 12.91 | 55.45 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 15.24 | 57.38 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 16.26 | 48.01 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 15.67 | 34.51 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 13.64 | 22.84 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 10.74 | 14.52 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 7.74 | 10.24 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 10.37 | 32.53 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 4.46 | 10.24 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 16.26 | 57.38 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.540674E+10 | -0.515797E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -248770674.8 | 60.05 | 0.00 | 0.00 |
February | 0.498839E+10 | -0.476848E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -219910103.4 | 60.05 | 0.00 | 0.00 |
March | 0.582697E+10 | -0.558766E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -239312936.4 | 60.05 | 0.00 | 0.00 |
April | 0.507603E+10 | -0.484790E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -228127973.9 | 60.05 | 0.00 | 0.00 |
May | 0.515457E+10 | -0.492077E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -233793970.8 | 60.05 | 0.00 | 0.00 |
June | 0.481715E+10 | -0.459196E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -225196473.3 | 60.05 | 0.00 | 0.00 |
July | 0.434268E+10 | -0.411123E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -231453151.4 | 60.05 | 0.00 | 0.00 |
August | 0.467851E+10 | -0.444657E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -231932402.7 | 60.05 | 0.00 | 0.00 |
September | 0.428198E+10 | -0.405707E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -224909458.6 | 60.05 | 0.00 | 0.00 |
October | 0.461544E+10 | -0.438146E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -233986183.2 | 60.05 | 0.00 | 0.00 |
November | 0.480615E+10 | -0.457646E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -229693885.9 | 60.05 | 0.00 | 0.00 |
December | 0.504481E+10 | -0.480114E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -243670195.8 | 60.05 | 0.00 | 0.00 |
Annual Sum or Average | 0.590394E+11 | -0.562487E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.279076E+10 | 60.05 | 0.00 | 0.00 |
Minimum of Months | 0.428198E+10 | -0.558766E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -248770674.8 | 60.05 | 0.00 | 0.00 |
Maximum of Months | 0.582697E+10 | -0.405707E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -219910103.4 | 60.05 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_1_DAYLCTRL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 226.83 | 0.51 | 0.48 | 01-JAN-08:50 | 6273.26 | 36.84 | 217.67 | 231.50 | 5291.76 | 37.85 | 219.83 | 215.00 |
February | 275.00 | 0.50 | 0.48 | 01-FEB-08:20 | 8487.19 | 37.17 | 268.17 | 259.33 | 3694.38 | 32.01 | 239.83 | 247.17 |
March | 304.00 | 0.50 | 0.48 | 01-MAR-07:49 | 9878.72 | 33.00 | 260.33 | 324.00 | 2070.36 | 22.60 | 220.50 | 295.33 |
April | 325.17 | 0.50 | 0.48 | 01-APR-08:50 | 2477.10 | 19.40 | 12.33 | 349.83 | 1440.65 | 21.67 | 201.00 | 318.00 |
May | 385.83 | 0.51 | 0.48 | 01-MAY-06:30 | 2176.98 | 19.18 | 4.83 | 398.00 | 1238.90 | 21.41 | 229.00 | 358.67 |
June | 434.17 | 0.52 | 0.48 | 01-JUN-13:39 | 1859.20 | 18.66 | 0.33 | 412.33 | 1093.17 | 20.93 | 236.67 | 367.17 |
July | 417.33 | 0.51 | 0.48 | 01-JUL-06:40 | 2002.78 | 19.05 | 3.83 | 406.17 | 1211.94 | 21.35 | 210.50 | 371.83 |
August | 421.33 | 0.52 | 0.48 | 01-AUG-06:49 | 2156.27 | 18.52 | 4.17 | 384.83 | 1310.49 | 20.80 | 196.33 | 349.83 |
September | 352.17 | 0.52 | 0.48 | 01-SEP-06:00 | 3064.20 | 20.00 | 42.83 | 327.50 | 1569.80 | 21.16 | 175.83 | 300.67 |
October | 317.67 | 0.50 | 0.48 | 01-OCT-08:39 | 8586.68 | 34.77 | 286.00 | 301.67 | 2494.90 | 25.27 | 212.83 | 285.67 |
November | 269.50 | 0.51 | 0.48 | 01-NOV-07:00 | 6399.81 | 37.03 | 260.33 | 250.50 | 5677.80 | 38.52 | 263.50 | 241.17 |
December | 236.83 | 0.51 | 0.48 | 01-DEC-08:50 | 4942.63 | 36.20 | 218.33 | 231.67 | 4382.40 | 38.87 | 239.50 | 219.67 |
Annual Sum or Average | 3965.83 | 0.51 | 4452.83 | 25.92 | 1579.17 | 3877.33 | 2329.43 | 25.57 | 2645.33 | 3570.17 | ||
Minimum of Months | 226.83 | 0.50 | 0.48 | 1859.20 | 18.52 | 0.33 | 231.50 | 1093.17 | 20.80 | 175.83 | 215.00 | |
Maximum of Months | 434.17 | 0.52 | 0.48 | 9878.72 | 37.17 | 286.00 | 412.33 | 5677.80 | 38.87 | 263.50 | 371.83 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_2_DAYLCTRL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 226.83 | 0.53 | 0.48 | 01-JAN-08:50 | 1952.47 | 23.81 | 89.67 | 216.83 | 1119.82 | 24.08 | 96.00 | 184.67 |
February | 275.00 | 0.52 | 0.48 | 01-FEB-08:09 | 2138.61 | 21.32 | 75.17 | 246.67 | 1142.84 | 22.07 | 95.83 | 215.33 |
March | 304.00 | 0.50 | 0.48 | 01-MAR-07:49 | 3409.89 | 22.89 | 95.00 | 319.67 | 1904.85 | 23.80 | 138.83 | 288.67 |
April | 325.17 | 0.50 | 0.48 | 01-APR-08:39 | 3428.91 | 22.11 | 85.33 | 356.67 | 1919.47 | 23.20 | 83.33 | 324.33 |
May | 385.83 | 0.50 | 0.48 | 01-MAY-05:40 | 3766.05 | 22.35 | 113.67 | 407.00 | 1661.06 | 22.30 | 69.17 | 372.17 |
June | 434.17 | 0.51 | 0.48 | 01-JUN-13:39 | 4581.35 | 22.70 | 134.17 | 423.17 | 2007.45 | 23.30 | 91.83 | 392.17 |
July | 417.33 | 0.49 | 0.48 | 01-JUL-06:40 | 4985.59 | 23.51 | 132.67 | 421.83 | 2149.07 | 23.14 | 79.83 | 396.33 |
August | 421.33 | 0.51 | 0.48 | 01-AUG-05:30 | 3936.63 | 21.82 | 115.67 | 390.83 | 2305.85 | 23.86 | 116.50 | 361.17 |
September | 352.17 | 0.52 | 0.48 | 01-SEP-06:19 | 2990.71 | 22.10 | 104.33 | 327.17 | 1672.13 | 23.07 | 112.67 | 298.00 |
October | 317.67 | 0.52 | 0.48 | 01-OCT-08:20 | 2673.23 | 22.50 | 107.33 | 290.00 | 1541.90 | 23.69 | 126.50 | 255.33 |
November | 269.50 | 0.53 | 0.48 | 01-NOV-07:49 | 1686.71 | 21.22 | 83.50 | 231.50 | 967.54 | 23.24 | 105.83 | 200.83 |
December | 236.83 | 0.54 | 0.48 | 01-DEC-08:50 | 1515.46 | 23.74 | 100.67 | 210.50 | 906.47 | 24.25 | 102.00 | 171.50 |
Annual Sum or Average | 3965.83 | 0.51 | 3298.15 | 22.48 | 1237.17 | 3841.83 | 1691.07 | 23.30 | 1218.33 | 3460.50 | ||
Minimum of Months | 226.83 | 0.49 | 0.48 | 1515.46 | 21.22 | 75.17 | 210.50 | 906.47 | 22.07 | 69.17 | 171.50 | |
Maximum of Months | 434.17 | 0.54 | 0.48 | 4985.59 | 23.81 | 134.17 | 423.17 | 2305.85 | 24.25 | 138.83 | 396.33 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_3_DAYLCTRL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 226.83 | 0.57 | 0.48 | 01-JAN-10:30 | 629.46 | 15.10 | 0.00 | 193.83 | 373.93 | 17.56 | 0.00 | 130.17 |
February | 275.00 | 0.54 | 0.48 | 01-FEB-11:20 | 688.71 | 16.11 | 0.00 | 232.00 | 425.76 | 18.59 | 0.00 | 178.50 |
March | 304.00 | 0.51 | 0.48 | 01-MAR-08:09 | 1086.71 | 18.10 | 0.00 | 312.67 | 641.07 | 20.37 | 52.50 | 272.67 |
April | 325.17 | 0.50 | 0.48 | 01-APR-08:00 | 1131.87 | 18.77 | 0.00 | 352.33 | 677.93 | 20.95 | 78.50 | 314.67 |
May | 385.83 | 0.49 | 0.48 | 01-MAY-06:10 | 1402.27 | 20.73 | 45.00 | 412.17 | 791.68 | 21.52 | 176.33 | 377.33 |
June | 434.17 | 0.50 | 0.48 | 01-JUN-13:39 | 1456.29 | 22.27 | 103.83 | 440.83 | 828.43 | 22.79 | 257.00 | 416.50 |
July | 417.33 | 0.49 | 0.48 | 01-JUL-06:40 | 1426.67 | 21.84 | 80.00 | 426.67 | 825.71 | 21.75 | 201.50 | 401.17 |
August | 421.33 | 0.50 | 0.48 | 01-AUG-05:49 | 1105.18 | 18.40 | 0.00 | 400.17 | 705.73 | 20.63 | 116.67 | 379.50 |
September | 352.17 | 0.52 | 0.48 | 01-SEP-06:00 | 902.93 | 17.41 | 0.00 | 324.33 | 562.56 | 19.68 | 23.50 | 280.83 |
October | 317.67 | 0.54 | 0.48 | 01-OCT-09:20 | 745.58 | 16.48 | 0.00 | 275.50 | 456.34 | 18.88 | 0.83 | 215.50 |
November | 269.50 | 0.57 | 0.48 | 01-NOV-08:00 | 590.53 | 15.22 | 0.00 | 210.67 | 356.85 | 17.71 | 0.00 | 141.67 |
December | 236.83 | 0.59 | 0.48 | 01-DEC-09:50 | 513.90 | 14.54 | 0.00 | 187.67 | 309.43 | 17.12 | 0.00 | 95.50 |
Annual Sum or Average | 3965.83 | 0.52 | 1033.99 | 18.38 | 228.83 | 3768.83 | 614.46 | 20.13 | 906.83 | 3204.00 | ||
Minimum of Months | 226.83 | 0.49 | 0.48 | 513.90 | 14.54 | 0.00 | 187.67 | 309.43 | 17.12 | 0.00 | 95.50 | |
Maximum of Months | 434.17 | 0.59 | 0.48 | 1456.29 | 22.27 | 103.83 | 440.83 | 828.43 | 22.79 | 257.00 | 416.50 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_4_DAYLCTRL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 226.83 | 0.54 | 0.48 | 01-JAN-10:30 | 1814.22 | 22.48 | 85.00 | 210.17 | 1064.47 | 23.02 | 88.00 | 174.33 |
February | 275.00 | 0.52 | 0.48 | 01-FEB-11:09 | 2259.95 | 21.30 | 77.50 | 243.67 | 1287.46 | 23.80 | 111.83 | 216.33 |
March | 304.00 | 0.50 | 0.48 | 01-MAR-08:20 | 3186.07 | 22.46 | 92.33 | 317.83 | 1782.84 | 24.43 | 134.00 | 288.00 |
April | 325.17 | 0.50 | 0.48 | 01-APR-08:00 | 3335.15 | 20.83 | 75.83 | 349.33 | 1882.16 | 22.08 | 74.50 | 315.67 |
May | 385.83 | 0.50 | 0.48 | 01-MAY-06:49 | 3803.68 | 19.78 | 75.17 | 403.50 | 1785.40 | 19.34 | 6.83 | 369.67 |
June | 434.17 | 0.51 | 0.48 | 01-JUN-13:39 | 3895.12 | 17.93 | 52.00 | 425.00 | 1768.55 | 19.02 | 5.17 | 393.33 |
July | 417.33 | 0.50 | 0.48 | 01-JUL-06:00 | 4518.84 | 19.88 | 79.67 | 410.50 | 2056.45 | 19.35 | 5.83 | 383.17 |
August | 421.33 | 0.51 | 0.48 | 01-AUG-06:49 | 3469.97 | 19.63 | 88.67 | 389.17 | 1953.60 | 21.12 | 72.83 | 360.83 |
September | 352.17 | 0.52 | 0.48 | 01-SEP-07:19 | 3449.58 | 21.56 | 98.83 | 328.00 | 1476.93 | 22.49 | 91.17 | 298.17 |
October | 317.67 | 0.52 | 0.48 | 01-OCT-09:20 | 2289.60 | 21.11 | 85.50 | 287.00 | 1308.92 | 23.30 | 115.67 | 254.67 |
November | 269.50 | 0.54 | 0.48 | 01-NOV-08:00 | 2025.51 | 23.26 | 103.17 | 230.17 | 1158.94 | 23.92 | 104.83 | 198.33 |
December | 236.83 | 0.55 | 0.48 | 01-DEC-09:50 | 1383.48 | 21.21 | 79.00 | 210.17 | 806.27 | 23.28 | 93.50 | 173.67 |
Annual Sum or Average | 3965.83 | 0.52 | 3128.81 | 20.71 | 992.67 | 3804.50 | 1595.32 | 21.77 | 904.17 | 3426.17 | ||
Minimum of Months | 226.83 | 0.50 | 0.48 | 1383.48 | 17.93 | 52.00 | 210.17 | 806.27 | 19.02 | 5.17 | 173.67 | |
Maximum of Months | 434.17 | 0.55 | 0.48 | 4518.84 | 23.26 | 103.17 | 425.00 | 2056.45 | 24.43 | 134.00 | 393.33 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_1_DAYLCTRL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 226.83 | 0.51 | 0.48 | 01-JAN-08:50 | 6080.72 | 36.57 | 216.17 | 230.50 | 5140.75 | 37.56 | 215.67 | 213.50 |
February | 275.00 | 0.50 | 0.48 | 01-FEB-08:20 | 8257.57 | 35.95 | 256.83 | 256.83 | 3536.16 | 30.59 | 180.17 | 246.50 |
March | 304.00 | 0.50 | 0.48 | 01-MAR-07:49 | 9686.47 | 32.23 | 253.67 | 322.50 | 1930.01 | 19.77 | 24.00 | 293.33 |
April | 325.17 | 0.51 | 0.48 | 01-APR-08:50 | 2348.85 | 15.61 | 0.00 | 347.50 | 1346.62 | 19.17 | 25.17 | 314.17 |
May | 385.83 | 0.51 | 0.48 | 01-MAY-06:40 | 2077.56 | 15.50 | 0.00 | 396.33 | 1170.25 | 19.00 | 18.33 | 355.67 |
June | 434.17 | 0.52 | 0.48 | 01-JUN-13:39 | 1776.49 | 15.07 | 0.00 | 409.50 | 1037.44 | 18.64 | 4.33 | 363.83 |
July | 417.33 | 0.51 | 0.48 | 01-JUL-06:49 | 1908.90 | 15.48 | 0.00 | 403.67 | 1146.52 | 19.08 | 17.67 | 369.00 |
August | 421.33 | 0.52 | 0.48 | 01-AUG-06:49 | 2042.59 | 14.78 | 0.00 | 382.00 | 1225.68 | 18.37 | 15.67 | 347.67 |
September | 352.17 | 0.52 | 0.48 | 01-SEP-06:00 | 2914.91 | 16.36 | 29.50 | 326.50 | 1454.90 | 18.54 | 27.33 | 298.33 |
October | 317.67 | 0.51 | 0.48 | 01-OCT-08:39 | 8396.08 | 33.93 | 280.00 | 301.17 | 2355.75 | 22.86 | 84.17 | 285.00 |
November | 269.50 | 0.51 | 0.48 | 01-NOV-07:00 | 6177.85 | 35.29 | 246.33 | 248.33 | 5538.72 | 38.30 | 263.00 | 239.83 |
December | 236.83 | 0.51 | 0.48 | 01-DEC-08:50 | 4693.74 | 33.05 | 197.00 | 228.33 | 4249.57 | 38.67 | 232.17 | 218.50 |
Annual Sum or Average | 3965.83 | 0.51 | 4301.49 | 23.23 | 1479.50 | 3853.17 | 2223.95 | 23.60 | 1107.67 | 3545.33 | ||
Minimum of Months | 226.83 | 0.50 | 0.48 | 1776.49 | 14.78 | 0.00 | 228.33 | 1037.44 | 18.37 | 4.33 | 213.50 | |
Maximum of Months | 434.17 | 0.52 | 0.48 | 9686.47 | 36.57 | 280.00 | 409.50 | 5538.72 | 38.67 | 263.00 | 369.00 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_2_DAYLCTRL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 226.83 | 0.53 | 0.48 | 01-JAN-08:50 | 1806.55 | 21.20 | 74.83 | 213.67 | 1078.39 | 23.86 | 86.17 | 181.33 |
February | 275.00 | 0.52 | 0.48 | 01-FEB-08:09 | 2068.59 | 20.82 | 75.17 | 244.67 | 1087.73 | 21.85 | 86.33 | 212.83 |
March | 304.00 | 0.50 | 0.48 | 01-MAR-07:49 | 3317.17 | 22.44 | 94.83 | 318.67 | 1831.71 | 23.60 | 126.00 | 286.17 |
April | 325.17 | 0.50 | 0.48 | 01-APR-08:39 | 3334.91 | 21.64 | 85.33 | 355.67 | 1845.02 | 23.01 | 73.83 | 320.67 |
May | 385.83 | 0.50 | 0.48 | 01-MAY-05:40 | 3675.09 | 21.90 | 113.67 | 406.00 | 1588.73 | 22.12 | 61.33 | 367.83 |
June | 434.17 | 0.51 | 0.48 | 01-JUN-13:39 | 4473.30 | 22.25 | 134.17 | 420.00 | 1908.06 | 22.43 | 79.83 | 388.00 |
July | 417.33 | 0.49 | 0.48 | 01-JUL-06:40 | 4869.09 | 23.06 | 132.67 | 419.50 | 2055.41 | 22.97 | 77.17 | 393.83 |
August | 421.33 | 0.51 | 0.48 | 01-AUG-05:40 | 3811.17 | 21.14 | 112.67 | 388.83 | 2221.52 | 23.68 | 107.50 | 359.00 |
September | 352.17 | 0.52 | 0.48 | 01-SEP-06:30 | 2808.81 | 19.99 | 85.17 | 325.17 | 1603.76 | 22.88 | 103.50 | 294.17 |
October | 317.67 | 0.52 | 0.48 | 01-OCT-08:30 | 2606.17 | 22.04 | 107.00 | 287.67 | 1488.60 | 23.48 | 119.17 | 253.83 |
November | 269.50 | 0.54 | 0.48 | 01-NOV-07:49 | 1634.38 | 20.54 | 81.00 | 230.00 | 927.34 | 23.02 | 96.17 | 198.17 |
December | 236.83 | 0.55 | 0.48 | 01-DEC-08:50 | 1395.67 | 20.78 | 80.17 | 206.67 | 874.89 | 24.03 | 94.83 | 167.17 |
Annual Sum or Average | 3965.83 | 0.51 | 3191.63 | 21.57 | 1176.67 | 3816.50 | 1621.47 | 23.03 | 1111.83 | 3423.00 | ||
Minimum of Months | 226.83 | 0.49 | 0.48 | 1395.67 | 19.99 | 74.83 | 206.67 | 874.89 | 21.85 | 61.33 | 167.17 | |
Maximum of Months | 434.17 | 0.55 | 0.48 | 4869.09 | 23.06 | 134.17 | 420.00 | 2221.52 | 24.03 | 126.00 | 393.83 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_3_DAYLCTRL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 226.83 | 0.58 | 0.48 | 01-JAN-10:50 | 605.53 | 11.41 | 0.00 | 190.33 | 360.77 | 15.06 | 0.00 | 122.83 |
February | 275.00 | 0.55 | 0.48 | 01-FEB-11:20 | 663.18 | 12.49 | 0.00 | 230.17 | 412.16 | 16.22 | 0.00 | 173.00 |
March | 304.00 | 0.51 | 0.48 | 01-MAR-08:20 | 1048.27 | 14.68 | 0.00 | 309.83 | 619.97 | 18.19 | 0.00 | 269.00 |
April | 325.17 | 0.50 | 0.48 | 01-APR-08:00 | 1092.52 | 15.47 | 0.00 | 350.33 | 656.71 | 18.99 | 5.33 | 311.50 |
May | 385.83 | 0.49 | 0.48 | 01-MAY-06:10 | 1354.31 | 17.61 | 38.50 | 411.33 | 798.05 | 20.86 | 61.00 | 377.33 |
June | 434.17 | 0.50 | 0.48 | 01-JUN-13:39 | 1405.89 | 19.58 | 96.67 | 439.33 | 799.67 | 20.84 | 76.33 | 413.17 |
July | 417.33 | 0.49 | 0.48 | 01-JUL-06:40 | 1379.31 | 19.04 | 72.17 | 425.17 | 799.73 | 19.75 | 48.00 | 398.00 |
August | 421.33 | 0.50 | 0.48 | 01-AUG-05:49 | 1067.64 | 15.06 | 0.00 | 398.83 | 685.77 | 18.67 | 11.83 | 377.17 |
September | 352.17 | 0.53 | 0.48 | 01-SEP-06:00 | 871.22 | 14.10 | 0.00 | 322.00 | 545.93 | 17.64 | 0.00 | 276.17 |
October | 317.67 | 0.54 | 0.48 | 01-OCT-12:39 | 718.37 | 12.96 | 0.00 | 271.00 | 441.79 | 16.62 | 0.00 | 209.83 |
November | 269.50 | 0.57 | 0.48 | 01-NOV-08:00 | 568.14 | 11.48 | 0.00 | 207.50 | 344.70 | 15.24 | 0.00 | 134.83 |
December | 236.83 | 0.59 | 0.48 | 01-DEC-09:00 | 493.14 | 10.70 | 0.00 | 182.00 | 298.07 | 14.50 | 0.00 | 83.67 |
Annual Sum or Average | 3965.83 | 0.52 | 997.76 | 15.08 | 207.33 | 3737.83 | 597.88 | 18.11 | 202.50 | 3146.50 | ||
Minimum of Months | 226.83 | 0.49 | 0.48 | 493.14 | 10.70 | 0.00 | 182.00 | 298.07 | 14.50 | 0.00 | 83.67 | |
Maximum of Months | 434.17 | 0.59 | 0.48 | 1405.89 | 19.58 | 96.67 | 439.33 | 799.73 | 20.86 | 76.33 | 413.17 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_4_DAYLCTRL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 226.83 | 0.55 | 0.48 | 01-JAN-10:30 | 1765.63 | 22.13 | 85.00 | 207.67 | 1027.42 | 22.94 | 86.50 | 172.00 |
February | 275.00 | 0.52 | 0.48 | 01-FEB-11:09 | 2195.54 | 20.88 | 77.33 | 242.00 | 1235.28 | 23.70 | 111.33 | 214.50 |
March | 304.00 | 0.51 | 0.48 | 01-MAR-08:20 | 3101.28 | 22.06 | 92.17 | 315.67 | 1690.18 | 23.47 | 120.33 | 283.67 |
April | 325.17 | 0.50 | 0.48 | 01-APR-09:09 | 3236.89 | 20.38 | 75.83 | 348.00 | 1806.57 | 21.93 | 69.33 | 312.50 |
May | 385.83 | 0.50 | 0.48 | 01-MAY-06:00 | 3636.52 | 19.32 | 75.00 | 401.00 | 1704.31 | 19.18 | 2.67 | 367.17 |
June | 434.17 | 0.51 | 0.48 | 01-JUN-13:39 | 3797.38 | 17.42 | 52.00 | 423.83 | 1692.97 | 18.85 | 4.33 | 389.33 |
July | 417.33 | 0.50 | 0.48 | 01-JUL-06:00 | 4410.39 | 19.41 | 79.67 | 409.33 | 1971.37 | 19.18 | 4.50 | 380.17 |
August | 421.33 | 0.51 | 0.48 | 01-AUG-06:00 | 3377.08 | 19.17 | 88.50 | 387.00 | 1880.38 | 20.97 | 67.50 | 357.50 |
September | 352.17 | 0.52 | 0.48 | 01-SEP-07:19 | 3367.39 | 21.14 | 98.67 | 326.00 | 1408.87 | 22.37 | 88.67 | 295.67 |
October | 317.67 | 0.52 | 0.48 | 01-OCT-12:39 | 2201.48 | 20.34 | 81.33 | 284.17 | 1254.65 | 23.19 | 113.17 | 250.83 |
November | 269.50 | 0.54 | 0.48 | 01-NOV-08:00 | 1869.01 | 20.69 | 82.33 | 227.17 | 1116.67 | 23.83 | 104.00 | 195.50 |
December | 236.83 | 0.55 | 0.48 | 01-DEC-09:50 | 1340.74 | 20.83 | 78.50 | 208.67 | 773.50 | 23.20 | 91.83 | 170.33 |
Annual Sum or Average | 3965.83 | 0.52 | 3031.22 | 20.10 | 966.33 | 3780.50 | 1528.17 | 21.58 | 864.17 | 3389.17 | ||
Minimum of Months | 226.83 | 0.50 | 0.48 | 1340.74 | 17.42 | 52.00 | 207.67 | 773.50 | 18.85 | 2.67 | 170.33 | |
Maximum of Months | 434.17 | 0.55 | 0.48 | 4410.39 | 22.13 | 98.67 | 423.83 | 1971.37 | 23.83 | 120.33 | 389.33 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_1_DAYLCTRL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 226.83 | 0.51 | 0.48 | 01-JAN-08:50 | 6080.72 | 36.57 | 216.17 | 230.50 | 5140.66 | 37.56 | 215.67 | 213.50 |
February | 275.00 | 0.50 | 0.48 | 01-FEB-08:20 | 8257.54 | 35.95 | 256.83 | 256.83 | 3536.06 | 30.59 | 180.17 | 246.50 |
March | 304.00 | 0.50 | 0.48 | 01-MAR-07:49 | 9686.33 | 32.23 | 253.67 | 322.50 | 1929.87 | 19.77 | 24.17 | 293.33 |
April | 325.17 | 0.51 | 0.48 | 01-APR-08:50 | 2348.71 | 15.61 | 0.00 | 347.50 | 1346.52 | 19.17 | 25.17 | 314.17 |
May | 385.83 | 0.51 | 0.48 | 01-MAY-06:40 | 2077.44 | 15.50 | 0.00 | 396.33 | 1170.16 | 19.00 | 18.33 | 355.67 |
June | 434.17 | 0.52 | 0.48 | 01-JUN-13:39 | 1776.40 | 15.07 | 0.00 | 409.50 | 1037.37 | 18.64 | 4.33 | 363.83 |
July | 417.33 | 0.51 | 0.48 | 01-JUL-06:49 | 1908.81 | 15.48 | 0.00 | 403.67 | 1146.44 | 19.08 | 17.67 | 369.00 |
August | 421.33 | 0.52 | 0.48 | 01-AUG-06:49 | 2042.49 | 14.79 | 0.00 | 382.00 | 1225.60 | 18.37 | 15.67 | 347.67 |
September | 352.17 | 0.52 | 0.48 | 01-SEP-06:00 | 2914.81 | 16.36 | 29.50 | 326.50 | 1454.80 | 18.55 | 27.33 | 298.33 |
October | 317.67 | 0.51 | 0.48 | 01-OCT-08:39 | 8396.03 | 33.93 | 280.00 | 301.17 | 2355.64 | 22.86 | 84.17 | 285.00 |
November | 269.50 | 0.51 | 0.48 | 01-NOV-07:00 | 6177.85 | 35.29 | 246.33 | 248.33 | 5538.63 | 38.30 | 263.00 | 239.83 |
December | 236.83 | 0.51 | 0.48 | 01-DEC-08:50 | 4693.76 | 33.05 | 197.00 | 228.33 | 4249.50 | 38.67 | 232.17 | 218.50 |
Annual Sum or Average | 3965.83 | 0.51 | 4301.41 | 23.23 | 1479.50 | 3853.17 | 2223.86 | 23.60 | 1107.83 | 3545.33 | ||
Minimum of Months | 226.83 | 0.50 | 0.48 | 1776.40 | 14.79 | 0.00 | 228.33 | 1037.37 | 18.37 | 4.33 | 213.50 | |
Maximum of Months | 434.17 | 0.52 | 0.48 | 9686.33 | 36.57 | 280.00 | 409.50 | 5538.63 | 38.67 | 263.00 | 369.00 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_2_DAYLCTRL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 226.83 | 0.53 | 0.48 | 01-JAN-08:50 | 1806.53 | 21.20 | 74.83 | 213.67 | 1078.35 | 23.86 | 86.17 | 181.33 |
February | 275.00 | 0.52 | 0.48 | 01-FEB-08:09 | 2068.57 | 20.83 | 75.17 | 244.67 | 1087.68 | 21.85 | 86.67 | 212.83 |
March | 304.00 | 0.50 | 0.48 | 01-MAR-07:49 | 3317.11 | 22.45 | 95.00 | 318.67 | 1831.63 | 23.60 | 126.00 | 286.17 |
April | 325.17 | 0.50 | 0.48 | 01-APR-08:39 | 3334.85 | 21.64 | 85.33 | 355.67 | 1844.95 | 23.01 | 73.83 | 320.67 |
May | 385.83 | 0.50 | 0.48 | 01-MAY-05:40 | 3675.02 | 21.90 | 113.67 | 406.00 | 1588.65 | 22.12 | 61.33 | 367.83 |
June | 434.17 | 0.51 | 0.48 | 01-JUN-13:39 | 4473.25 | 22.25 | 134.17 | 420.00 | 1907.98 | 22.43 | 79.83 | 388.00 |
July | 417.33 | 0.49 | 0.48 | 01-JUL-06:40 | 4869.05 | 23.06 | 132.67 | 419.50 | 2055.34 | 22.97 | 77.17 | 393.83 |
August | 421.33 | 0.51 | 0.48 | 01-AUG-05:40 | 3811.13 | 21.14 | 112.67 | 388.83 | 2221.45 | 23.69 | 107.50 | 359.00 |
September | 352.17 | 0.52 | 0.48 | 01-SEP-06:30 | 2808.77 | 19.99 | 85.17 | 325.17 | 1603.69 | 22.88 | 103.50 | 294.17 |
October | 317.67 | 0.52 | 0.48 | 01-OCT-08:30 | 2606.15 | 22.04 | 107.00 | 287.67 | 1488.55 | 23.48 | 119.17 | 253.83 |
November | 269.50 | 0.54 | 0.48 | 01-NOV-07:49 | 1634.36 | 20.54 | 81.00 | 230.00 | 927.30 | 23.02 | 96.17 | 198.17 |
December | 236.83 | 0.55 | 0.48 | 01-DEC-08:50 | 1395.65 | 20.79 | 80.17 | 206.67 | 874.85 | 24.03 | 94.83 | 167.17 |
Annual Sum or Average | 3965.83 | 0.51 | 3191.59 | 21.57 | 1176.83 | 3816.50 | 1621.41 | 23.03 | 1112.17 | 3423.00 | ||
Minimum of Months | 226.83 | 0.49 | 0.48 | 1395.65 | 19.99 | 74.83 | 206.67 | 874.85 | 21.85 | 61.33 | 167.17 | |
Maximum of Months | 434.17 | 0.55 | 0.48 | 4869.05 | 23.06 | 134.17 | 420.00 | 2221.45 | 24.03 | 126.00 | 393.83 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_3_DAYLCTRL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 226.83 | 0.58 | 0.48 | 01-JAN-10:50 | 605.51 | 11.41 | 0.00 | 190.33 | 360.75 | 15.07 | 0.00 | 122.83 |
February | 275.00 | 0.55 | 0.48 | 01-FEB-11:20 | 663.16 | 12.49 | 0.00 | 230.17 | 412.14 | 16.22 | 0.00 | 173.00 |
March | 304.00 | 0.51 | 0.48 | 01-MAR-08:20 | 1048.23 | 14.69 | 0.00 | 309.83 | 619.93 | 18.19 | 0.00 | 269.00 |
April | 325.17 | 0.50 | 0.48 | 01-APR-08:00 | 1092.48 | 15.47 | 0.00 | 350.33 | 656.66 | 18.99 | 5.33 | 311.50 |
May | 385.83 | 0.49 | 0.48 | 01-MAY-06:10 | 1354.27 | 17.61 | 38.50 | 411.33 | 798.00 | 20.86 | 61.00 | 377.33 |
June | 434.17 | 0.50 | 0.48 | 01-JUN-13:39 | 1405.86 | 19.58 | 96.67 | 439.33 | 799.62 | 20.84 | 76.33 | 413.17 |
July | 417.33 | 0.49 | 0.48 | 01-JUL-06:40 | 1379.28 | 19.04 | 72.17 | 425.17 | 799.69 | 19.75 | 48.00 | 398.00 |
August | 421.33 | 0.50 | 0.48 | 01-AUG-05:49 | 1067.62 | 15.06 | 0.00 | 398.83 | 685.74 | 18.67 | 12.00 | 377.17 |
September | 352.17 | 0.53 | 0.48 | 01-SEP-06:00 | 871.20 | 14.10 | 0.00 | 322.00 | 545.90 | 17.64 | 0.00 | 276.17 |
October | 317.67 | 0.54 | 0.48 | 01-OCT-12:39 | 718.35 | 12.96 | 0.00 | 271.00 | 441.76 | 16.62 | 0.00 | 209.83 |
November | 269.50 | 0.57 | 0.48 | 01-NOV-08:00 | 568.13 | 11.48 | 0.00 | 207.50 | 344.68 | 15.24 | 0.00 | 134.83 |
December | 236.83 | 0.59 | 0.48 | 01-DEC-09:00 | 493.13 | 10.70 | 0.00 | 182.00 | 298.05 | 14.50 | 0.00 | 83.67 |
Annual Sum or Average | 3965.83 | 0.52 | 997.74 | 15.08 | 207.33 | 3737.83 | 597.84 | 18.11 | 202.67 | 3146.50 | ||
Minimum of Months | 226.83 | 0.49 | 0.48 | 493.13 | 10.70 | 0.00 | 182.00 | 298.05 | 14.50 | 0.00 | 83.67 | |
Maximum of Months | 434.17 | 0.59 | 0.48 | 1405.86 | 19.58 | 96.67 | 439.33 | 799.69 | 20.86 | 76.33 | 413.17 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_4_DAYLCTRL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 226.83 | 0.55 | 0.48 | 01-JAN-10:30 | 1765.60 | 22.13 | 85.00 | 207.67 | 1027.38 | 22.94 | 86.67 | 172.00 |
February | 275.00 | 0.52 | 0.48 | 01-FEB-11:09 | 2195.51 | 20.89 | 77.33 | 242.00 | 1235.23 | 23.70 | 111.33 | 214.50 |
March | 304.00 | 0.51 | 0.48 | 01-MAR-08:20 | 3101.22 | 22.06 | 92.17 | 315.67 | 1690.10 | 23.47 | 120.33 | 283.67 |
April | 325.17 | 0.50 | 0.48 | 01-APR-09:09 | 3236.83 | 20.38 | 75.83 | 348.00 | 1806.49 | 21.93 | 69.33 | 312.50 |
May | 385.83 | 0.50 | 0.48 | 01-MAY-06:00 | 3636.45 | 19.32 | 75.00 | 401.00 | 1704.22 | 19.18 | 2.67 | 367.17 |
June | 434.17 | 0.51 | 0.48 | 01-JUN-13:39 | 3797.32 | 17.42 | 52.00 | 423.83 | 1692.89 | 18.85 | 4.33 | 389.33 |
July | 417.33 | 0.50 | 0.48 | 01-JUL-06:00 | 4410.34 | 19.41 | 79.67 | 409.33 | 1971.29 | 19.19 | 4.67 | 380.17 |
August | 421.33 | 0.51 | 0.48 | 01-AUG-06:00 | 3377.03 | 19.17 | 88.50 | 387.00 | 1880.31 | 20.97 | 67.50 | 357.50 |
September | 352.17 | 0.52 | 0.48 | 01-SEP-07:19 | 3367.36 | 21.14 | 98.67 | 326.00 | 1408.81 | 22.37 | 88.67 | 295.67 |
October | 317.67 | 0.52 | 0.48 | 01-OCT-12:39 | 2201.46 | 20.34 | 81.33 | 284.17 | 1254.60 | 23.20 | 113.17 | 250.67 |
November | 269.50 | 0.54 | 0.48 | 01-NOV-08:00 | 1868.99 | 20.69 | 82.33 | 227.17 | 1116.63 | 23.83 | 104.00 | 195.50 |
December | 236.83 | 0.55 | 0.48 | 01-DEC-09:50 | 1340.73 | 20.83 | 78.50 | 208.67 | 773.46 | 23.20 | 91.83 | 170.33 |
Annual Sum or Average | 3965.83 | 0.52 | 3031.18 | 20.10 | 966.33 | 3780.50 | 1528.10 | 21.58 | 864.50 | 3389.00 | ||
Minimum of Months | 226.83 | 0.50 | 0.48 | 1340.73 | 17.42 | 52.00 | 207.67 | 773.46 | 18.85 | 2.67 | 170.33 | |
Maximum of Months | 434.17 | 0.55 | 0.48 | 4410.34 | 22.13 | 98.67 | 423.83 | 1971.29 | 23.83 | 120.33 | 389.33 |
Report: CoilReportMonthly
For: PACU_VAV_BOT HEATING COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.189434E+11 | 35166.97 | 10-JAN-22:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.103113E+11 | 32637.73 | 01-FEB-07:19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.574709E+10 | 28862.15 | 06-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.120110E+10 | 12281.58 | 29-APR-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.634540E+09 | 9076.42 | 08-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 426510.86 | 299.60 | 17-JUN-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 310714.83 | 5.27 | 19-JUL-15:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 106810.82 | 5.00 | 01-AUG-14:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 34234505.77 | 2689.18 | 18-SEP-21:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.678465E+09 | 12189.92 | 10-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.407887E+10 | 21337.18 | 27-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.120766E+11 | 34326.01 | 29-DEC-08:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.537065E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 106810.82 | 5.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.189434E+11 | 35166.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_BOTTOM VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.156081E+09 | 13485.77 | 10-JAN-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 8991465.72 | 13488.86 | 06-FEB-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.165073E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.156081E+09 | 13488.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.787997E+10 | 10474.76 | 10-JAN-22:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.444361E+10 | 10018.22 | 06-FEB-07:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.340286E+10 | 9999.91 | 15-MAR-06:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.197787E+10 | 10100.52 | 27-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.157712E+10 | 10482.55 | 22-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.317920E+09 | 10121.60 | 16-JUN-06:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 30936468.67 | 7911.07 | 05-JUL-06:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.193538E+09 | 10122.56 | 18-AUG-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.546454E+09 | 10489.74 | 12-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.928809E+09 | 10221.42 | 02-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.239432E+10 | 10030.74 | 06-NOV-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.517730E+10 | 10237.78 | 29-DEC-08:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.288707E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 30936468.67 | 7911.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.787997E+10 | 10489.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.400710E+10 | 7444.03 | 10-JAN-22:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.193497E+10 | 7119.32 | 06-FEB-07:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.995737E+09 | 7093.88 | 10-MAR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.216427E+09 | 7090.66 | 22-APR-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 80712068.07 | 7081.38 | 08-MAY-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 411052.80 | 1215.13 | 20-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 34186414.29 | 7084.03 | 05-OCT-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.688369E+09 | 7095.94 | 27-NOV-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.226336E+10 | 7265.67 | 29-DEC-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.102213E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.400710E+10 | 7444.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.625963E+10 | 8012.07 | 10-JAN-22:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.336816E+10 | 7667.61 | 06-FEB-07:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.191592E+10 | 7656.34 | 22-MAR-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.437574E+09 | 7648.69 | 28-APR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.150167E+09 | 7653.23 | 08-MAY-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 2667825.49 | 2627.45 | 20-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 63124575.62 | 7645.06 | 10-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.104621E+10 | 7653.38 | 29-NOV-06:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.351463E+10 | 7832.42 | 29-DEC-08:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.167581E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.625963E+10 | 8012.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.435385E+10 | 7800.88 | 10-JAN-22:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.208885E+10 | 7459.72 | 06-FEB-07:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.123449E+10 | 7432.76 | 10-MAR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.303671E+09 | 7429.05 | 22-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.105585E+09 | 7424.71 | 10-MAY-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 489170.80 | 983.42 | 17-JUN-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 2406399.26 | 1446.92 | 19-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 50559418.02 | 7422.34 | 05-OCT-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.740519E+09 | 7435.24 | 27-NOV-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.245817E+10 | 7597.54 | 29-DEC-08:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.113386E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.435385E+10 | 7800.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_MID HEATING COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.195946E+11 | 36948.19 | 10-JAN-22:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.111528E+11 | 33341.81 | 01-FEB-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.699693E+10 | 27487.00 | 04-MAR-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.206675E+10 | 13415.92 | 29-APR-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.121510E+10 | 10615.38 | 08-MAY-06:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 28688711.93 | 3622.02 | 16-JUN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 260457.41 | 4.98 | 20-JUL-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 73272.18 | 4.28 | 22-AUG-12:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.229905E+09 | 5037.25 | 19-SEP-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.139353E+10 | 13632.60 | 10-OCT-06:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.515070E+10 | 22530.25 | 27-NOV-07:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.132343E+11 | 35651.25 | 29-DEC-07:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.610636E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 73272.18 | 4.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.195946E+11 | 36948.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_MID VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.288742E+10 | 19550.49 | 02-JAN-06:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.954718E+09 | 19544.80 | 13-FEB-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.351140E+09 | 19505.58 | 07-MAR-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 8594602.46 | 19269.74 | 01-MAY-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 3338185.86 | 19278.86 | 10-OCT-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.303533E+09 | 19538.79 | 29-NOV-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.122558E+10 | 19538.26 | 19-DEC-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.573433E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.288742E+10 | 19550.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.419906E+10 | 10967.23 | 10-JAN-22:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.169266E+10 | 10670.48 | 14-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.904612E+09 | 10670.36 | 10-MAR-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.186381E+09 | 10621.70 | 22-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.138706E+09 | 10643.61 | 08-MAY-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 151425.62 | 865.08 | 17-JUN-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 10575772.23 | 7120.31 | 19-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 88449293.19 | 10672.91 | 10-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.891595E+09 | 10663.02 | 27-NOV-06:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.247106E+10 | 10756.24 | 29-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.105833E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.419906E+10 | 10967.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.407016E+10 | 8027.15 | 10-JAN-22:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.187427E+10 | 7814.75 | 03-FEB-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.914898E+09 | 7806.96 | 10-MAR-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.157787E+09 | 7755.25 | 21-APR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 91601869.81 | 7781.59 | 08-MAY-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 13435796.86 | 6426.81 | 19-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.142520E+09 | 7808.53 | 10-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.103429E+10 | 7802.44 | 27-NOV-06:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.265483E+10 | 7804.00 | 13-DEC-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.109538E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.407016E+10 | 8027.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.580610E+10 | 8376.25 | 10-JAN-21:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.266509E+10 | 8182.29 | 08-FEB-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.115787E+10 | 8178.47 | 08-MAR-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.139091E+09 | 8151.93 | 29-APR-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 84561031.39 | 8153.36 | 01-MAY-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6966015.72 | 6078.37 | 19-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.125037E+09 | 8156.81 | 10-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.119699E+10 | 8176.89 | 13-NOV-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.354325E+10 | 8328.39 | 29-DEC-09:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.147250E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.580610E+10 | 8376.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.427120E+10 | 8263.24 | 10-JAN-22:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.197694E+10 | 8036.23 | 14-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.108047E+10 | 8036.06 | 10-MAR-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.217445E+09 | 7989.34 | 12-APR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.122761E+09 | 8009.89 | 08-MAY-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 1579126.66 | 2447.17 | 17-JUN-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 337767.09 | 949.84 | 18-AUG-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 21271088.85 | 6461.67 | 19-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.176574E+09 | 8037.63 | 10-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.107006E+10 | 8031.55 | 27-NOV-06:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.276090E+10 | 8033.10 | 13-DEC-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.116995E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.427120E+10 | 8263.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_TOP HEATING COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.219102E+11 | 37079.57 | 10-JAN-22:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.122178E+11 | 35833.71 | 01-FEB-07:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.797037E+10 | 32808.88 | 04-MAR-07:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.257459E+10 | 15984.52 | 29-APR-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.148970E+10 | 12427.41 | 08-MAY-06:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 92059345.79 | 5280.36 | 16-JUN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 195730.70 | 4.89 | 19-JUL-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 1037073.86 | 965.42 | 18-AUG-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.441780E+09 | 7067.70 | 19-SEP-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.189488E+10 | 16263.83 | 10-OCT-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.592097E+10 | 22640.21 | 27-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.149754E+11 | 36253.77 | 29-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.694889E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 195730.70 | 4.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.219102E+11 | 37079.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_TOP VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.852038E+10 | 26685.72 | 02-JAN-06:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.370812E+10 | 26696.99 | 13-FEB-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.182411E+10 | 26692.12 | 10-MAR-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.252235E+09 | 26618.33 | 28-APR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.232876E+09 | 26687.93 | 08-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 3497959.24 | 7044.96 | 19-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.181742E+09 | 26656.91 | 10-OCT-05:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.199869E+10 | 26691.00 | 29-NOV-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.553615E+10 | 26691.45 | 07-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.222578E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.852038E+10 | 26696.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.685216E+10 | 13212.87 | 10-JAN-22:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.319043E+10 | 12741.58 | 01-FEB-07:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.222058E+10 | 12638.86 | 06-MAR-05:14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.719510E+09 | 12629.64 | 29-APR-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.484920E+09 | 12640.58 | 09-MAY-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 19204894.17 | 10182.99 | 17-JUN-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6266557.19 | 9389.07 | 18-AUG-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.120022E+09 | 12571.76 | 19-SEP-05:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.500507E+09 | 12635.11 | 11-OCT-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.202295E+10 | 12634.92 | 27-NOV-05:14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.468709E+10 | 12924.95 | 29-DEC-08:25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.208236E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.685216E+10 | 13212.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.589428E+10 | 9241.11 | 10-JAN-22:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.292997E+10 | 8911.00 | 01-FEB-07:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.178853E+10 | 8838.58 | 10-MAR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.465519E+09 | 8833.35 | 29-APR-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.253408E+09 | 8837.43 | 09-MAY-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 4684005.39 | 3193.21 | 16-JUN-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 1300582.00 | 871.10 | 17-AUG-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 95079555.67 | 8795.37 | 19-SEP-05:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.478873E+09 | 8838.35 | 11-OCT-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.193069E+10 | 8836.46 | 27-NOV-05:14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.427666E+10 | 9020.10 | 29-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.181190E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.589428E+10 | 9241.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.895604E+10 | 10201.93 | 10-JAN-22:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.461809E+10 | 9881.39 | 01-FEB-08:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.270866E+10 | 9789.60 | 20-MAR-05:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.642788E+09 | 9773.94 | 22-APR-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.363516E+09 | 9790.05 | 08-MAY-05:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 3071290.02 | 4686.77 | 17-JUN-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 1364288.64 | 3802.53 | 18-AUG-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.102230E+09 | 9746.74 | 13-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.649306E+09 | 9793.41 | 05-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.277698E+10 | 9790.52 | 30-NOV-06:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.638413E+10 | 10058.91 | 29-DEC-08:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.272062E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.895604E+10 | 10201.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.634847E+10 | 9855.80 | 10-JAN-22:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.325440E+10 | 9502.49 | 01-FEB-07:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.221515E+10 | 9424.31 | 10-MAR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.678464E+09 | 9419.14 | 29-APR-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.389502E+09 | 9423.17 | 09-MAY-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 22288078.68 | 6522.89 | 17-JUN-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 9832205.32 | 6062.84 | 18-AUG-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.155748E+09 | 9377.61 | 19-SEP-05:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.660599E+09 | 9424.09 | 11-OCT-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.217301E+10 | 9416.57 | 27-NOV-05:43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.460539E+10 | 9619.37 | 29-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.205129E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.634847E+10 | 9855.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_BOT COOLING COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.185777E+09 | 0.185770E+09 | 14469.84 | 27-FEB-15:40 | 14469.84 | 0.00 |
March | 0.00 | 0.00 | 37611.29 | 37611.29 | 250.74 | 23-MAR-06:03 | 250.74 | 0.00 |
April | 0.00 | 0.00 | 0.190249E+10 | 0.189322E+10 | 28445.41 | 06-APR-16:00 | 28445.41 | 0.00 |
May | 0.00 | 0.00 | 0.780736E+10 | 0.764472E+10 | 53935.87 | 19-MAY-15:30 | 53935.87 | 0.00 |
June | 0.00 | 0.00 | 0.286883E+11 | 0.274967E+11 | 67388.74 | 20-JUN-16:00 | 59253.01 | 0.00 |
July | 0.00 | 0.00 | 0.500020E+11 | 0.484322E+11 | 83646.60 | 17-JUL-16:00 | 83646.60 | 0.00 |
August | 0.00 | 0.00 | 0.425761E+11 | 0.421868E+11 | 76315.67 | 07-AUG-16:00 | 76315.67 | 0.00 |
September | 0.00 | 0.00 | 0.204001E+11 | 0.187518E+11 | 103868.84 | 07-SEP-14:55 | 54813.15 | 0.00 |
October | 0.00 | 0.00 | 0.446782E+10 | 0.445248E+10 | 49482.53 | 18-OCT-15:40 | 49482.53 | 0.00 |
November | 0.00 | 0.00 | 0.164302E+09 | 0.160415E+09 | 6084.47 | 17-NOV-17:00 | 6084.47 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.156194E+12 | 0.151204E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.500020E+11 | 0.484322E+11 | 103868.84 | 83646.60 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_MID COOLING COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.181164E+09 | 0.181164E+09 | 12550.64 | 27-FEB-13:30 | 12550.64 | 0.00 |
March | 0.00 | 0.00 | 1354643.00 | 1354643.00 | 340.86 | 14-MAR-13:40 | 340.86 | 0.00 |
April | 0.00 | 0.00 | 0.202466E+10 | 0.201443E+10 | 29594.25 | 06-APR-16:00 | 29594.25 | 0.00 |
May | 0.00 | 0.00 | 0.785031E+10 | 0.768895E+10 | 54714.36 | 19-MAY-15:30 | 54714.36 | 0.00 |
June | 0.00 | 0.00 | 0.275249E+11 | 0.263806E+11 | 64017.44 | 20-JUN-16:00 | 56242.49 | 0.00 |
July | 0.00 | 0.00 | 0.460576E+11 | 0.447147E+11 | 79050.53 | 17-JUL-15:30 | 79050.53 | 0.00 |
August | 0.00 | 0.00 | 0.387182E+11 | 0.383495E+11 | 75379.54 | 07-AUG-15:30 | 75379.54 | 0.00 |
September | 0.00 | 0.00 | 0.180035E+11 | 0.166135E+11 | 98172.94 | 07-SEP-14:55 | 51807.34 | 0.00 |
October | 0.00 | 0.00 | 0.375756E+10 | 0.374328E+10 | 44382.65 | 18-OCT-15:50 | 44382.65 | 0.00 |
November | 0.00 | 0.00 | 0.155966E+09 | 0.148513E+09 | 5579.05 | 04-NOV-14:00 | 5579.05 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.144275E+12 | 0.139836E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.460576E+11 | 0.447147E+11 | 98172.94 | 79050.53 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_TOP COOLING COIL
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 1111996.74 | 1102426.80 | 1367.98 | 30-JAN-06:40 | 1367.98 | 0.00 |
February | 0.00 | 0.00 | 0.159223E+09 | 0.159222E+09 | 11252.70 | 27-FEB-15:30 | 11252.70 | 0.00 |
March | 0.00 | 0.00 | 68128.95 | 68128.95 | 340.64 | 08-MAR-05:43 | 340.64 | 0.00 |
April | 0.00 | 0.00 | 0.199734E+10 | 0.198239E+10 | 30786.32 | 06-APR-16:00 | 30786.32 | 0.00 |
May | 0.00 | 0.00 | 0.827110E+10 | 0.804353E+10 | 63690.30 | 19-MAY-15:30 | 63690.30 | 0.00 |
June | 0.00 | 0.00 | 0.293564E+11 | 0.280460E+11 | 72770.31 | 20-JUN-15:10 | 64767.77 | 0.00 |
July | 0.00 | 0.00 | 0.490847E+11 | 0.475405E+11 | 91285.91 | 17-JUL-15:20 | 91285.91 | 0.00 |
August | 0.00 | 0.00 | 0.407274E+11 | 0.402200E+11 | 87977.02 | 06-AUG-16:11 | 87977.02 | 0.00 |
September | 0.00 | 0.00 | 0.183481E+11 | 0.168109E+11 | 98544.56 | 07-SEP-15:20 | 53427.00 | 0.00 |
October | 0.00 | 0.00 | 0.346500E+10 | 0.343088E+10 | 45446.35 | 18-OCT-15:00 | 45446.35 | 0.00 |
November | 0.00 | 0.00 | 0.144916E+09 | 0.134233E+09 | 5329.96 | 04-NOV-14:00 | 5329.96 | 0.00 |
December | 0.00 | 0.00 | 1073522.51 | 1072360.09 | 664.54 | 18-DEC-06:05 | 664.54 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.151556E+12 | 0.146370E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 68128.95 | 68128.95 | 340.64 | 340.64 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.490847E+11 | 0.475405E+11 | 98544.56 | 91285.91 | 0.00 |
Report: PlantLoopDemandReportMonthly
For: HEATSYS1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 52243.48 | 267299.89 | 17-JAN-06:11 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 29701.85 | 263014.02 | 13-FEB-06:11 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 16093.97 | 235261.91 | 01-MAR-07:01 |
April | 0.00 | 0.00 | 01-APR-00:10 | 4682.77 | 219495.76 | 28-APR-06:01 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 2755.93 | 215952.49 | 01-MAY-06:01 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 182.51 | 39143.91 | 17-JUN-06:03 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 13.55 | 17514.41 | 05-JUL-06:06 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 79.02 | 33496.09 | 18-AUG-06:03 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 684.04 | 153188.86 | 19-SEP-06:03 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 2977.82 | 222372.98 | 05-OCT-06:01 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 13564.50 | 219843.12 | 22-NOV-06:11 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 34046.45 | 246447.08 | 29-DEC-07:11 |
Annual Sum or Average | 0.00 | 13039.95 | ||||
Minimum of Months | 0.00 | 0.00 | 13.55 | 17514.41 | ||
Maximum of Months | 0.00 | 0.00 | 52243.48 | 267299.89 |
Report: PlantLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 1916.14 | 7053.97 | 31-JAN-13:00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 1961.40 | 7091.46 | 17-FEB-12:20 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 2076.18 | 7078.84 | 01-MAR-12:17 |
April | 0.00 | 0.00 | 01-APR-00:10 | 1860.80 | 6886.35 | 03-APR-11:30 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 1827.61 | 6581.45 | 01-MAY-12:00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 1762.01 | 6179.87 | 01-JUN-11:17 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 1525.91 | 5809.86 | 03-JUL-11:20 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 1650.70 | 5604.87 | 01-AUG-11:30 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 1556.08 | 5739.54 | 29-SEP-11:40 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 1626.60 | 6081.16 | 31-OCT-11:17 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 1756.14 | 6469.99 | 30-NOV-12:40 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 1783.17 | 6811.81 | 29-DEC-12:55 |
Annual Sum or Average | 0.00 | 1774.15 | ||||
Minimum of Months | 0.00 | 0.00 | 1525.91 | 5604.87 | ||
Maximum of Months | 0.00 | 0.00 | 2076.18 | 7091.46 |
Report: FanReportMonthly
For: PACU_VAV_BOT FAN
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.186643E+10 | 0.38 | 3139.59 | 02-JAN-07:01 | 0.91 |
February | 0.159546E+10 | 0.36 | 3302.51 | 28-FEB-16:30 | 0.94 |
March | 0.193492E+10 | 0.37 | 3174.44 | 01-MAR-16:30 | 0.92 |
April | 0.208118E+10 | 0.36 | 5050.24 | 27-APR-06:02 | 1.20 |
May | 0.278342E+10 | 0.40 | 7081.77 | 19-MAY-15:40 | 1.46 |
June | 0.506001E+10 | 0.56 | 10131.39 | 29-JUN-14:30 | 1.83 |
July | 0.668072E+10 | 0.63 | 12983.54 | 25-JUL-15:50 | 2.14 |
August | 0.642366E+10 | 0.62 | 11860.46 | 09-AUG-16:00 | 2.02 |
September | 0.415227E+10 | 0.50 | 12983.54 | 07-SEP-14:50 | 2.12 |
October | 0.272412E+10 | 0.39 | 5917.39 | 18-OCT-16:00 | 1.32 |
November | 0.187132E+10 | 0.34 | 4425.33 | 06-NOV-06:01 | 1.11 |
December | 0.163569E+10 | 0.34 | 1879.08 | 18-DEC-06:01 | 0.71 |
Annual Sum or Average | 0.388092E+11 | 0.44 | |||
Minimum of Months | 0.159546E+10 | 0.34 | 1879.08 | 0.71 | |
Maximum of Months | 0.668072E+10 | 0.63 | 12983.54 | 2.14 |
Report: FanReportMonthly
For: PACU_VAV_MID FAN
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.192960E+10 | 0.39 | 3325.23 | 02-JAN-06:03 | 0.97 |
February | 0.161349E+10 | 0.36 | 3325.23 | 01-FEB-07:01 | 0.98 |
March | 0.186249E+10 | 0.37 | 3325.23 | 06-MAR-06:05 | 0.98 |
April | 0.190840E+10 | 0.36 | 5220.09 | 25-APR-15:50 | 1.27 |
May | 0.252924E+10 | 0.40 | 7834.78 | 19-MAY-15:30 | 1.61 |
June | 0.466089E+10 | 0.55 | 9640.88 | 29-JUN-14:30 | 1.84 |
July | 0.603678E+10 | 0.61 | 12271.56 | 17-JUL-10:50 | 2.14 |
August | 0.564095E+10 | 0.59 | 12271.56 | 07-AUG-15:30 | 2.14 |
September | 0.326739E+10 | 0.46 | 12271.56 | 07-SEP-15:00 | 2.12 |
October | 0.205949E+10 | 0.36 | 5981.86 | 18-OCT-15:50 | 1.37 |
November | 0.163519E+10 | 0.34 | 3325.23 | 13-NOV-07:01 | 0.98 |
December | 0.165041E+10 | 0.35 | 3325.23 | 01-DEC-07:02 | 0.98 |
Annual Sum or Average | 0.347943E+11 | 0.43 | |||
Minimum of Months | 0.161349E+10 | 0.34 | 3325.23 | 0.97 | |
Maximum of Months | 0.603678E+10 | 0.61 | 12271.56 | 2.14 |
Report: FanReportMonthly
For: PACU_VAV_TOP FAN
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.231552E+10 | 0.44 | 3231.96 | 02-JAN-05:01 | 0.89 |
February | 0.177360E+10 | 0.38 | 3231.96 | 01-FEB-06:01 | 0.89 |
March | 0.195808E+10 | 0.38 | 3231.96 | 01-MAR-07:01 | 0.89 |
April | 0.184564E+10 | 0.35 | 4848.61 | 25-APR-15:50 | 1.12 |
May | 0.240419E+10 | 0.38 | 7918.04 | 19-MAY-15:30 | 1.49 |
June | 0.424504E+10 | 0.50 | 9485.71 | 29-JUN-14:30 | 1.67 |
July | 0.552602E+10 | 0.54 | 14064.00 | 17-JUL-15:00 | 2.14 |
August | 0.507092E+10 | 0.53 | 13327.22 | 07-AUG-15:40 | 2.07 |
September | 0.287892E+10 | 0.41 | 9837.97 | 01-SEP-15:50 | 1.71 |
October | 0.187314E+10 | 0.34 | 4975.89 | 18-OCT-15:40 | 1.13 |
November | 0.174965E+10 | 0.36 | 3231.96 | 06-NOV-07:02 | 0.89 |
December | 0.207968E+10 | 0.41 | 3231.96 | 01-DEC-06:01 | 0.89 |
Annual Sum or Average | 0.337204E+11 | 0.42 | |||
Minimum of Months | 0.174965E+10 | 0.34 | 3231.96 | 0.89 | |
Maximum of Months | 0.552602E+10 | 0.54 | 14064.00 | 2.14 |
Report: PumpReportMonthly
For: HEATSYS1 PUMP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.898418E+09 | 0.808576E+09 | 1075.65 | 09-JAN-07:07 | 968.08 | 968.08 | 41.63 | 3.46 |
February | 0.488543E+09 | 0.439689E+09 | 1000.90 | 01-FEB-07:15 | 900.81 | 900.81 | 42.56 | 3.19 |
March | 0.301989E+09 | 0.271790E+09 | 954.70 | 06-MAR-07:01 | 859.23 | 859.23 | 43.22 | 2.97 |
April | 87944900.68 | 79150410.61 | 875.88 | 29-APR-06:03 | 788.29 | 788.29 | 38.67 | 2.29 |
May | 57944200.23 | 52149780.20 | 883.38 | 08-MAY-06:01 | 795.04 | 795.04 | 39.72 | 2.37 |
June | 5685878.07 | 5117290.26 | 391.60 | 17-JUN-06:03 | 352.44 | 352.44 | 40.70 | 0.49 |
July | 367873.88 | 331086.49 | 136.89 | 12-JUL-06:06 | 123.21 | 123.21 | 39.14 | 0.15 |
August | 2776900.55 | 2499210.50 | 412.20 | 18-AUG-06:03 | 370.98 | 370.98 | 44.50 | 0.52 |
September | 15652756.68 | 14087481.01 | 758.09 | 19-SEP-06:03 | 682.28 | 682.28 | 33.55 | 1.39 |
October | 58761249.65 | 52885124.68 | 889.35 | 10-OCT-06:01 | 800.42 | 800.42 | 40.56 | 2.44 |
November | 0.245741E+09 | 0.221167E+09 | 920.38 | 27-NOV-07:25 | 828.34 | 828.34 | 42.02 | 2.73 |
December | 0.615463E+09 | 0.553917E+09 | 1036.28 | 29-DEC-07:11 | 932.65 | 932.65 | 42.29 | 3.33 |
Annual Sum or Average | 0.277929E+10 | 0.250136E+10 | ||||||
Minimum of Months | 367873.88 | 331086.49 | 136.89 | 123.21 | 123.21 | 33.55 | 0.15 | |
Maximum of Months | 0.898418E+09 | 0.808576E+09 | 1075.65 | 968.08 | 968.08 | 44.50 | 3.46 |
Report: PumpReportMonthly
For: SWHSYS1 PUMP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 12379742.02 | 3713922.60 | 6.85 | 01-JAN-06:10 | 2.06 | 2.06 | 57.91 | 0.05 |
February | 11196021.66 | 3358806.50 | 6.85 | 01-FEB-06:01 | 2.06 | 2.06 | 56.77 | 0.05 |
March | 12675672.10 | 3802701.63 | 6.85 | 01-MAR-06:01 | 2.06 | 2.06 | 56.80 | 0.05 |
April | 11960507.72 | 3588152.32 | 6.85 | 01-APR-05:05 | 2.06 | 2.06 | 56.48 | 0.05 |
May | 12527707.06 | 3758312.12 | 6.85 | 01-MAY-05:01 | 2.06 | 2.06 | 57.27 | 0.05 |
June | 12231776.97 | 3669533.09 | 6.85 | 01-JUN-05:03 | 2.06 | 2.06 | 57.01 | 0.05 |
July | 12256437.81 | 3676931.34 | 6.85 | 01-JUL-05:03 | 2.06 | 2.06 | 57.19 | 0.05 |
August | 12675672.10 | 3802701.63 | 6.85 | 01-AUG-05:03 | 2.06 | 2.06 | 57.30 | 0.05 |
September | 11960507.72 | 3588152.32 | 6.85 | 01-SEP-05:03 | 2.06 | 2.06 | 57.25 | 0.05 |
October | 12379742.02 | 3713922.60 | 6.85 | 01-OCT-05:10 | 2.06 | 2.06 | 58.12 | 0.05 |
November | 12059151.09 | 3617745.33 | 6.85 | 01-NOV-05:03 | 2.06 | 2.06 | 56.99 | 0.05 |
December | 12256437.81 | 3676931.34 | 6.85 | 01-DEC-06:01 | 2.06 | 2.06 | 57.05 | 0.05 |
Annual Sum or Average | 0.146559E+09 | 43967812.83 | ||||||
Minimum of Months | 11196021.66 | 3358806.50 | 6.85 | 2.06 | 2.06 | 56.48 | 0.05 | |
Maximum of Months | 12675672.10 | 3802701.63 | 6.85 | 2.06 | 2.06 | 58.12 | 0.05 |
Report: CondLoopDemandReportMonthly
For: HEATSYS1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 39.09 | 39.09 | 52243.48 | 267299.89 | 17-JAN-06:11 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 35.46 | 35.46 | 29701.85 | 263014.02 | 13-FEB-06:11 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.41 | 25.41 | 16093.97 | 235261.91 | 01-MAR-07:01 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.69 | 27.69 | 4682.77 | 219495.76 | 28-APR-06:01 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 22.33 | 22.33 | 2755.93 | 215952.49 | 01-MAY-06:01 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 43.61 | 43.61 | 182.51 | 39143.91 | 17-JUN-06:03 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 30.74 | 30.74 | 13.55 | 17514.41 | 05-JUL-06:06 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 36.17 | 36.17 | 79.02 | 33496.09 | 18-AUG-06:03 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 36.74 | 36.74 | 684.04 | 153188.86 | 19-SEP-06:03 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 39.62 | 39.62 | 2977.82 | 222372.98 | 05-OCT-06:01 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 26.83 | 26.83 | 13564.50 | 219843.12 | 22-NOV-06:11 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 32.44 | 32.44 | 34046.45 | 246447.08 | 29-DEC-07:11 |
Annual Sum or Average | 0.00 | 13039.95 | ||||||
Minimum of Months | 0.00 | 0.00 | 22.33 | 22.33 | 13.55 | 17514.41 | ||
Maximum of Months | 0.00 | 0.00 | 43.61 | 43.61 | 52243.48 | 267299.89 |
Report: CondLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 57.91 | 57.91 | 1916.14 | 7053.97 | 31-JAN-13:00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 57.29 | 57.29 | 1961.40 | 7091.46 | 17-FEB-12:20 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 57.28 | 57.28 | 2076.18 | 7078.84 | 01-MAR-12:17 |
April | 0.00 | 0.00 | 01-APR-00:10 | 57.35 | 57.35 | 1860.80 | 6886.35 | 03-APR-11:30 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 57.99 | 57.99 | 1827.61 | 6581.45 | 01-MAY-12:00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 57.63 | 57.63 | 1762.01 | 6179.87 | 01-JUN-11:17 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 57.77 | 57.77 | 1525.91 | 5809.86 | 03-JUL-11:20 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 57.86 | 57.86 | 1650.70 | 5604.87 | 01-AUG-11:30 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 57.87 | 57.87 | 1556.08 | 5739.54 | 29-SEP-11:40 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 56.90 | 56.90 | 1626.60 | 6081.16 | 31-OCT-11:17 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 57.67 | 57.67 | 1756.14 | 6469.99 | 30-NOV-12:40 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 57.52 | 57.52 | 1783.17 | 6811.81 | 29-DEC-12:55 |
Annual Sum or Average | 0.00 | 1774.15 | ||||||
Minimum of Months | 0.00 | 0.00 | 56.90 | 56.90 | 1525.91 | 5604.87 | ||
Maximum of Months | 0.00 | 0.00 | 57.99 | 57.99 | 2076.18 | 7091.46 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_BOT
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.416000E+11 | 0.00 | 0.00 | 0.186643E+10 | 0.00 | 0.00 |
February | 0.221559E+11 | 0.00 | 0.00 | 0.164177E+10 | 0.00 | 0.00 |
March | 0.132961E+11 | 0.00 | 0.00 | 0.193493E+10 | 0.00 | 0.00 |
April | 0.413664E+10 | 0.00 | 0.00 | 0.254327E+10 | 0.00 | 0.00 |
May | 0.254812E+10 | 0.00 | 0.00 | 0.460989E+10 | 0.00 | 0.00 |
June | 0.318836E+09 | 0.00 | 0.00 | 0.116754E+11 | 0.00 | 0.00 |
July | 31247183.50 | 0.00 | 0.00 | 0.185648E+11 | 0.00 | 0.00 |
August | 0.193645E+09 | 0.00 | 0.00 | 0.164282E+11 | 0.00 | 0.00 |
September | 0.586174E+09 | 0.00 | 0.00 | 0.887892E+10 | 0.00 | 0.00 |
October | 0.175514E+10 | 0.00 | 0.00 | 0.375185E+10 | 0.00 | 0.00 |
November | 0.894828E+10 | 0.00 | 0.00 | 0.191455E+10 | 0.00 | 0.00 |
December | 0.254901E+11 | 0.00 | 0.00 | 0.163569E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.121060E+12 | 0.00 | 0.00 | 0.754456E+11 | 0.00 | 0.00 |
Minimum of Months | 31247183.50 | 0.00 | 0.00 | 0.163569E+10 | 0.00 | 0.00 |
Maximum of Months | 0.416000E+11 | 0.00 | 0.00 | 0.185648E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_MID
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.408285E+11 | 0.00 | 0.00 | 0.192960E+10 | 0.00 | 0.00 |
February | 0.203165E+11 | 0.00 | 0.00 | 0.165885E+10 | 0.00 | 0.00 |
March | 0.114059E+11 | 0.00 | 0.00 | 0.186285E+10 | 0.00 | 0.00 |
April | 0.276745E+10 | 0.00 | 0.00 | 0.239755E+10 | 0.00 | 0.00 |
May | 0.166132E+10 | 0.00 | 0.00 | 0.435926E+10 | 0.00 | 0.00 |
June | 30419264.21 | 0.00 | 0.00 | 0.110060E+11 | 0.00 | 0.00 |
July | 260457.41 | 0.00 | 0.00 | 0.170092E+11 | 0.00 | 0.00 |
August | 411039.27 | 0.00 | 0.00 | 0.147761E+11 | 0.00 | 0.00 |
September | 0.282154E+09 | 0.00 | 0.00 | 0.745456E+10 | 0.00 | 0.00 |
October | 0.192944E+10 | 0.00 | 0.00 | 0.293381E+10 | 0.00 | 0.00 |
November | 0.964717E+10 | 0.00 | 0.00 | 0.167635E+10 | 0.00 | 0.00 |
December | 0.258899E+11 | 0.00 | 0.00 | 0.165041E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.114760E+12 | 0.00 | 0.00 | 0.687145E+11 | 0.00 | 0.00 |
Minimum of Months | 260457.41 | 0.00 | 0.00 | 0.165041E+10 | 0.00 | 0.00 |
Maximum of Months | 0.408285E+11 | 0.00 | 0.00 | 0.170092E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_TOP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.584815E+11 | 0.00 | 0.00 | 0.231583E+10 | 0.00 | 0.00 |
February | 0.299188E+11 | 0.00 | 0.00 | 0.181419E+10 | 0.00 | 0.00 |
March | 0.187274E+11 | 0.00 | 0.00 | 0.195810E+10 | 0.00 | 0.00 |
April | 0.533311E+10 | 0.00 | 0.00 | 0.233473E+10 | 0.00 | 0.00 |
May | 0.321392E+10 | 0.00 | 0.00 | 0.434742E+10 | 0.00 | 0.00 |
June | 0.141308E+09 | 0.00 | 0.00 | 0.110639E+11 | 0.00 | 0.00 |
July | 195730.70 | 0.00 | 0.00 | 0.173229E+11 | 0.00 | 0.00 |
August | 19800707.03 | 0.00 | 0.00 | 0.147804E+11 | 0.00 | 0.00 |
September | 0.918358E+09 | 0.00 | 0.00 | 0.719817E+10 | 0.00 | 0.00 |
October | 0.436591E+10 | 0.00 | 0.00 | 0.269713E+10 | 0.00 | 0.00 |
November | 0.168233E+11 | 0.00 | 0.00 | 0.178803E+10 | 0.00 | 0.00 |
December | 0.404648E+11 | 0.00 | 0.00 | 0.207997E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.178408E+12 | 0.00 | 0.00 | 0.697008E+11 | 0.00 | 0.00 |
Minimum of Months | 195730.70 | 0.00 | 0.00 | 0.178803E+10 | 0.00 | 0.00 |
Maximum of Months | 0.584815E+11 | 0.00 | 0.00 | 0.173229E+11 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_BOT
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.186643E+10 | 0.00 | 0.416000E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.159546E+10 | 0.185777E+09 | 0.221559E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.193492E+10 | 37611.29 | 0.132961E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.208118E+10 | 0.190249E+10 | 0.413664E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.278342E+10 | 0.780736E+10 | 0.254812E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.506001E+10 | 0.286883E+11 | 0.318836E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.668072E+10 | 0.500020E+11 | 31247183.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.642366E+10 | 0.425761E+11 | 0.193645E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.415227E+10 | 0.204001E+11 | 0.586174E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.272412E+10 | 0.446782E+10 | 0.175514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.187132E+10 | 0.164302E+09 | 0.894828E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.163569E+10 | 0.00 | 0.254901E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.388092E+11 | 0.156194E+12 | 0.121060E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.159546E+10 | 0.00 | 31247183.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.668072E+10 | 0.500020E+11 | 0.416000E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_MID
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.192960E+10 | 0.00 | 0.408285E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.161349E+10 | 0.181164E+09 | 0.203165E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.186249E+10 | 1354643.00 | 0.114059E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.190840E+10 | 0.202466E+10 | 0.276745E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.252924E+10 | 0.785031E+10 | 0.166132E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.466089E+10 | 0.275249E+11 | 30419264.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.603678E+10 | 0.460576E+11 | 260457.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.564095E+10 | 0.387182E+11 | 411039.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.326739E+10 | 0.180035E+11 | 0.282154E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.205949E+10 | 0.375756E+10 | 0.192944E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.163519E+10 | 0.155966E+09 | 0.964717E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.165041E+10 | 0.00 | 0.258899E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.347943E+11 | 0.144275E+12 | 0.114760E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.161349E+10 | 0.00 | 260457.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.603678E+10 | 0.460576E+11 | 0.408285E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_TOP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.231552E+10 | 1111996.74 | 0.584815E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.177360E+10 | 0.159223E+09 | 0.299188E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.195808E+10 | 68128.95 | 0.187274E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.184564E+10 | 0.199734E+10 | 0.533311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.240419E+10 | 0.827110E+10 | 0.321392E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.424504E+10 | 0.293564E+11 | 0.141308E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.552602E+10 | 0.490847E+11 | 195730.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.507092E+10 | 0.407274E+11 | 19800707.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.287892E+10 | 0.183481E+11 | 0.918358E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.187314E+10 | 0.346500E+10 | 0.436591E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.174965E+10 | 0.144916E+09 | 0.168233E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.207968E+10 | 1073522.51 | 0.404648E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.337204E+11 | 0.151556E+12 | 0.178408E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.174965E+10 | 68128.95 | 195730.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.552602E+10 | 0.490847E+11 | 0.584815E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_BOT
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.186643E+10 | 0.416000E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.159546E+10 | 0.221559E+11 | 0.00 | 0.00 | 46308631.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.193492E+10 | 0.132961E+11 | 0.00 | 0.00 | 10220.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.208118E+10 | 0.413664E+10 | 0.00 | 0.00 | 0.462090E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.278342E+10 | 0.254812E+10 | 0.00 | 0.00 | 0.182647E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.506001E+10 | 0.318836E+09 | 0.00 | 0.00 | 0.661534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.668072E+10 | 31247183.50 | 0.00 | 0.00 | 0.118840E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.642366E+10 | 0.193645E+09 | 0.00 | 0.00 | 0.100045E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.415227E+10 | 0.586174E+09 | 0.00 | 0.00 | 0.472665E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.272412E+10 | 0.175514E+10 | 0.00 | 0.00 | 0.102773E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.187132E+10 | 0.894828E+10 | 0.00 | 0.00 | 43226350.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.163569E+10 | 0.254901E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.388092E+11 | 0.121060E+12 | 0.00 | 0.00 | 0.366364E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.159546E+10 | 31247183.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.668072E+10 | 0.416000E+11 | 0.00 | 0.00 | 0.118840E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_MID
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.192960E+10 | 0.408285E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.161349E+10 | 0.203165E+11 | 0.00 | 0.00 | 45360885.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.186249E+10 | 0.114059E+11 | 0.00 | 0.00 | 367810.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.190840E+10 | 0.276745E+10 | 0.00 | 0.00 | 0.489148E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.252924E+10 | 0.166132E+10 | 0.00 | 0.00 | 0.183002E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.466089E+10 | 30419264.21 | 0.00 | 0.00 | 0.634511E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.603678E+10 | 260457.41 | 0.00 | 0.00 | 0.109724E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.564095E+10 | 411039.27 | 0.00 | 0.00 | 0.913513E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.326739E+10 | 0.282154E+09 | 0.00 | 0.00 | 0.418716E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.205949E+10 | 0.192944E+10 | 0.00 | 0.00 | 0.874317E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.163519E+10 | 0.964717E+10 | 0.00 | 0.00 | 41163514.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.165041E+10 | 0.258899E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.347943E+11 | 0.114760E+12 | 0.00 | 0.00 | 0.339202E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.161349E+10 | 260457.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.603678E+10 | 0.408285E+11 | 0.00 | 0.00 | 0.109724E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_TOP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.231552E+10 | 0.584815E+11 | 0.00 | 0.00 | 300716.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.177360E+10 | 0.299188E+11 | 0.00 | 0.00 | 40596953.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.195808E+10 | 0.187274E+11 | 0.00 | 0.00 | 18502.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.184564E+10 | 0.533311E+10 | 0.00 | 0.00 | 0.489088E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.240419E+10 | 0.321392E+10 | 0.00 | 0.00 | 0.194323E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.424504E+10 | 0.141308E+09 | 0.00 | 0.00 | 0.681886E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.552602E+10 | 195730.70 | 0.00 | 0.00 | 0.117969E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.507092E+10 | 19800707.03 | 0.00 | 0.00 | 0.970944E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.287892E+10 | 0.918358E+09 | 0.00 | 0.00 | 0.431925E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.187314E+10 | 0.436591E+10 | 0.00 | 0.00 | 0.823989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.174965E+10 | 0.168233E+11 | 0.00 | 0.00 | 38382713.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.207968E+10 | 0.404648E+11 | 0.00 | 0.00 | 291630.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.337204E+11 | 0.178408E+12 | 0.00 | 0.00 | 0.359804E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.174965E+10 | 195730.70 | 0.00 | 0.00 | 18502.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.552602E+10 | 0.584815E+11 | 0.00 | 0.00 | 0.117969E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.133976E+11 | 0.00 | 0.00 | 2842174.33 | 0.00 | 75642207.03 | 0.421969E+10 | 0.00 | 0.27 |
February | 0.827844E+10 | 0.00 | 0.00 | 10361239.11 | 0.00 | 2043075.01 | 0.707118E+10 | 0.00 | 0.34 |
March | 0.359250E+10 | 0.00 | 0.00 | 25841337.70 | 0.00 | 0.00 | 0.146632E+11 | 0.00 | 0.40 |
April | 0.909024E+09 | 0.00 | 0.00 | 32462310.20 | 0.00 | 0.00 | 0.167274E+11 | 0.00 | 0.59 |
May | 0.100207E+10 | 16593157.83 | 0.00 | 37520889.71 | 2638684.78 | 0.00 | 0.181209E+11 | 0.00 | 0.80 |
June | 0.622185E+09 | 0.181496E+09 | 0.00 | 42246403.81 | 27604200.69 | 0.00 | 0.161038E+11 | 0.00 | 1.10 |
July | 0.643081E+09 | 0.379462E+09 | 0.00 | 35303322.85 | 16084812.28 | 0.00 | 0.870790E+10 | 0.00 | 0.92 |
August | 0.611310E+09 | 0.206444E+09 | 0.00 | 43354843.23 | 17757115.68 | 0.00 | 0.134760E+11 | 0.00 | 1.07 |
September | 0.712252E+09 | 0.282356E+09 | 0.00 | 40587767.07 | 15135526.37 | 0.00 | 0.177311E+11 | 0.00 | 1.00 |
October | 0.811931E+09 | 0.00 | 0.00 | 39810948.59 | 0.00 | 0.00 | 0.196431E+11 | 0.00 | 0.76 |
November | 0.259683E+10 | 0.00 | 0.00 | 26229543.98 | 0.00 | 0.00 | 0.146455E+11 | 0.00 | 0.47 |
December | 0.892285E+10 | 0.00 | 0.00 | 11734961.70 | 0.00 | 0.00 | 0.759818E+10 | 0.00 | 0.30 |
Annual Sum or Average | 0.421001E+11 | 0.106635E+10 | 0.00 | 0.348296E+09 | 79220339.80 | 77685282.03 | 0.158708E+12 | 0.00 | 0.67 |
Minimum of Months | 0.611310E+09 | 0.00 | 0.00 | 2842174.33 | 0.00 | 0.00 | 0.421969E+10 | 0.00 | 0.27 |
Maximum of Months | 0.133976E+11 | 0.379462E+09 | 0.00 | 43354843.23 | 27604200.69 | 75642207.03 | 0.196431E+11 | 0.00 | 1.10 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.139460E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.300373E+10 | 0.00 | 0.00 | 0.26 |
February | 0.121454E+11 | 0.00 | 0.00 | 464921.00 | 0.00 | 0.866111E+09 | 0.492144E+09 | 0.00 | 0.29 |
March | 0.109862E+11 | 0.00 | 0.00 | 2198648.94 | 0.00 | 0.162613E+09 | 0.291424E+10 | 0.00 | 0.31 |
April | 0.608245E+10 | 0.00 | 0.00 | 8584859.12 | 0.00 | 0.00 | 0.622046E+10 | 0.00 | 0.42 |
May | 0.445523E+10 | 9750388.71 | 0.00 | 14793582.61 | 6149014.48 | 979244.23 | 0.830494E+10 | 0.00 | 0.54 |
June | 0.148796E+10 | 0.139924E+09 | 0.00 | 25467816.41 | 21879551.00 | 0.00 | 0.986194E+10 | 0.00 | 0.77 |
July | 0.972915E+09 | 0.275484E+09 | 0.00 | 22511753.99 | 14975207.90 | 0.00 | 0.544220E+10 | 0.00 | 0.66 |
August | 0.112380E+10 | 0.152552E+09 | 0.00 | 26477426.20 | 18301630.57 | 0.00 | 0.823619E+10 | 0.00 | 0.74 |
September | 0.241685E+10 | 0.211080E+09 | 0.00 | 19044852.23 | 14965899.23 | 0.00 | 0.895674E+10 | 0.00 | 0.64 |
October | 0.545217E+10 | 0.00 | 0.00 | 11356991.21 | 0.00 | 645013.53 | 0.690960E+10 | 0.00 | 0.46 |
November | 0.938374E+10 | 0.00 | 0.00 | 2740078.97 | 0.00 | 98000860.81 | 0.254419E+10 | 0.00 | 0.32 |
December | 0.133635E+11 | 0.00 | 0.00 | 71580.98 | 0.00 | 0.104262E+10 | 0.150766E+09 | 0.00 | 0.26 |
Annual Sum or Average | 0.818162E+11 | 0.788790E+09 | 0.00 | 0.133713E+09 | 76271303.18 | 0.517470E+10 | 0.600334E+11 | 0.00 | 0.47 |
Minimum of Months | 0.972915E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.26 |
Maximum of Months | 0.139460E+11 | 0.275484E+09 | 0.00 | 26477426.20 | 21879551.00 | 0.300373E+10 | 0.986194E+10 | 0.00 | 0.77 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.821455E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.703956E+10 | 0.00 | 0.00 | 0.25 |
February | 0.940694E+10 | 0.00 | 0.00 | 179998.23 | 0.00 | 0.284123E+10 | 0.203191E+09 | 0.00 | 0.28 |
March | 0.110355E+11 | 0.00 | 0.00 | 682151.50 | 0.00 | 0.129196E+10 | 0.888360E+09 | 0.00 | 0.30 |
April | 0.789888E+10 | 0.00 | 0.00 | 4648526.63 | 0.00 | 73161885.10 | 0.367547E+10 | 0.00 | 0.40 |
May | 0.580533E+10 | 3507078.02 | 0.00 | 10702521.81 | 1884660.83 | 96482078.08 | 0.648535E+10 | 0.00 | 0.53 |
June | 0.206596E+10 | 99343526.73 | 0.00 | 23085819.76 | 7979036.07 | 0.00 | 0.874339E+10 | 0.00 | 0.78 |
July | 0.135966E+10 | 0.205604E+09 | 0.00 | 20820636.99 | 14566846.71 | 0.00 | 0.462776E+10 | 0.00 | 0.67 |
August | 0.169248E+10 | 0.101638E+09 | 0.00 | 23572875.72 | 14969800.83 | 0.00 | 0.671450E+10 | 0.00 | 0.72 |
September | 0.391333E+10 | 0.200699E+09 | 0.00 | 12681104.80 | 11063163.24 | 1675654.87 | 0.599684E+10 | 0.00 | 0.59 |
October | 0.732360E+10 | 0.00 | 0.00 | 4458769.98 | 0.00 | 84606695.91 | 0.346558E+10 | 0.00 | 0.42 |
November | 0.901862E+10 | 0.00 | 0.00 | 493858.11 | 0.00 | 0.105002E+10 | 0.813007E+09 | 0.00 | 0.31 |
December | 0.897278E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.430764E+10 | 0.00 | 0.00 | 0.25 |
Annual Sum or Average | 0.767076E+11 | 0.610792E+09 | 0.00 | 0.101326E+09 | 50463507.67 | 0.167863E+11 | 0.416135E+11 | 0.00 | 0.46 |
Minimum of Months | 0.135966E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.25 |
Maximum of Months | 0.110355E+11 | 0.205604E+09 | 0.00 | 23572875.72 | 14969800.83 | 0.703956E+10 | 0.874339E+10 | 0.00 | 0.78 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.104857E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.436000E+10 | 0.00 | 0.00 | 0.32 |
February | 0.619495E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.237853E+10 | 0.00 | 0.00 | 0.31 |
March | 0.150094E+10 | 0.00 | 0.00 | 4060.65 | 0.00 | 0.137887E+10 | 13191881.28 | 0.00 | 0.31 |
April | 0.164824E+10 | 0.00 | 0.00 | 573758.46 | 0.00 | 0.347790E+09 | 0.428776E+09 | 0.00 | 0.40 |
May | 0.132910E+10 | 1780722.86 | 0.00 | 2466130.62 | 397375.01 | 0.171841E+09 | 0.122000E+10 | 0.00 | 0.59 |
June | 0.552674E+09 | 33561820.98 | 0.00 | 6244490.50 | 1682355.52 | 519929.18 | 0.203837E+10 | 0.00 | 0.96 |
July | 0.294106E+09 | 71666333.57 | 0.00 | 5879359.45 | 3071375.39 | 0.00 | 0.114941E+10 | 0.00 | 0.84 |
August | 0.521659E+09 | 38842796.58 | 0.00 | 5524345.13 | 3156337.04 | 172158.65 | 0.134471E+10 | 0.00 | 0.82 |
September | 0.112452E+10 | 58720960.40 | 0.00 | 2160914.58 | 2417754.38 | 44869206.30 | 0.847123E+09 | 0.00 | 0.60 |
October | 0.161789E+10 | 0.00 | 0.00 | 389477.77 | 0.00 | 0.368849E+09 | 0.267997E+09 | 0.00 | 0.41 |
November | 0.101235E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137727E+10 | 0.00 | 0.00 | 0.32 |
December | 0.322495E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.302895E+10 | 0.00 | 0.00 | 0.29 |
Annual Sum or Average | 0.106483E+11 | 0.204573E+09 | 0.00 | 23242537.17 | 10725197.36 | 0.134577E+11 | 0.730958E+10 | 0.00 | 0.51 |
Minimum of Months | 0.104857E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.29 |
Maximum of Months | 0.164824E+10 | 71666333.57 | 0.00 | 6244490.50 | 3156337.04 | 0.436000E+10 | 0.203837E+10 | 0.00 | 0.96 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.410153E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.356789E+10 | 0.00 | 0.00 | 0.47 |
February | 0.101998E+10 | 0.00 | 0.00 | 63730.87 | 0.00 | 0.196054E+10 | 59868426.09 | 0.00 | 0.51 |
March | 0.177979E+10 | 0.00 | 0.00 | 616186.08 | 0.00 | 0.108059E+10 | 0.373255E+09 | 0.00 | 0.55 |
April | 0.152042E+10 | 0.00 | 0.00 | 2297604.85 | 0.00 | 0.270339E+09 | 0.136939E+10 | 0.00 | 0.82 |
May | 0.121377E+10 | 1288516.49 | 0.00 | 4086383.99 | 448970.30 | 0.149318E+09 | 0.213977E+10 | 0.00 | 1.15 |
June | 0.530355E+09 | 26859474.57 | 0.00 | 8882704.75 | 1900953.80 | 927700.13 | 0.278272E+10 | 0.00 | 1.86 |
July | 0.267313E+09 | 59925806.95 | 0.00 | 9610875.87 | 2964024.15 | 0.00 | 0.190558E+10 | 0.00 | 1.80 |
August | 0.493269E+09 | 39471179.29 | 0.00 | 7779208.26 | 3351513.23 | 0.00 | 0.219030E+10 | 0.00 | 1.73 |
September | 0.107768E+10 | 48857988.69 | 0.00 | 3332549.97 | 2579068.51 | 40140817.52 | 0.145452E+10 | 0.00 | 1.17 |
October | 0.173808E+10 | 0.00 | 0.00 | 983816.11 | 0.00 | 0.281794E+09 | 0.581072E+09 | 0.00 | 0.76 |
November | 0.141381E+10 | 0.00 | 0.00 | 21155.12 | 0.00 | 0.117749E+10 | 18162840.57 | 0.00 | 0.55 |
December | 0.630757E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.263925E+10 | 0.00 | 0.00 | 0.46 |
Annual Sum or Average | 0.120954E+11 | 0.176403E+09 | 0.00 | 37674215.87 | 11244529.98 | 0.111683E+11 | 0.128746E+11 | 0.00 | 0.99 |
Minimum of Months | 0.267313E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.46 |
Maximum of Months | 0.177979E+10 | 59925806.95 | 0.00 | 9610875.87 | 3351513.23 | 0.356789E+10 | 0.278272E+10 | 0.00 | 1.86 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.102477E+10 | 0.00 | 0.00 | 1038097.34 | 0.00 | 0.376084E+10 | 0.658232E+09 | 0.00 | 0.41 |
February | 0.130169E+10 | 0.00 | 0.00 | 3145260.23 | 0.00 | 0.194289E+10 | 0.163921E+10 | 0.00 | 0.59 |
March | 0.183337E+10 | 0.00 | 0.00 | 5355087.48 | 0.00 | 0.128878E+10 | 0.268806E+10 | 0.00 | 0.66 |
April | 0.172591E+10 | 0.00 | 0.00 | 5020744.14 | 0.00 | 0.428725E+09 | 0.280884E+10 | 0.00 | 0.87 |
May | 0.161812E+10 | 2527125.31 | 0.00 | 6013629.96 | 591863.80 | 0.261135E+09 | 0.299402E+10 | 0.00 | 1.06 |
June | 0.975306E+09 | 46321276.42 | 0.00 | 8568060.04 | 2288166.77 | 7462022.54 | 0.274343E+10 | 0.00 | 1.36 |
July | 0.539874E+09 | 0.103335E+09 | 0.00 | 8632067.58 | 2577344.21 | 0.00 | 0.162732E+10 | 0.00 | 1.23 |
August | 0.795306E+09 | 78019133.38 | 0.00 | 10834941.95 | 3193176.18 | 1672927.79 | 0.252787E+10 | 0.00 | 1.51 |
September | 0.123070E+10 | 0.140858E+09 | 0.00 | 8134503.74 | 1110051.39 | 45037099.74 | 0.321186E+10 | 0.00 | 1.42 |
October | 0.160827E+10 | 0.00 | 0.00 | 7824469.54 | 0.00 | 0.268104E+09 | 0.352352E+10 | 0.00 | 1.11 |
November | 0.144914E+10 | 0.00 | 0.00 | 3764271.41 | 0.00 | 0.116169E+10 | 0.192168E+10 | 0.00 | 0.62 |
December | 0.125706E+10 | 0.00 | 0.00 | 1564528.45 | 0.00 | 0.261260E+10 | 0.784949E+09 | 0.00 | 0.42 |
Annual Sum or Average | 0.153595E+11 | 0.371061E+09 | 0.00 | 69895661.86 | 9760602.35 | 0.117789E+11 | 0.271290E+11 | 0.00 | 0.94 |
Minimum of Months | 0.539874E+09 | 0.00 | 0.00 | 1038097.34 | 0.00 | 0.00 | 0.658232E+09 | 0.00 | 0.41 |
Maximum of Months | 0.183337E+10 | 0.140858E+09 | 0.00 | 10834941.95 | 3193176.18 | 0.376084E+10 | 0.352352E+10 | 0.00 | 1.51 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.419265E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401317E+10 | 0.00 | 0.00 | 0.52 |
February | 0.981072E+09 | 0.00 | 0.00 | 271482.07 | 0.00 | 0.227794E+10 | 0.173307E+09 | 0.00 | 0.58 |
March | 0.178049E+10 | 0.00 | 0.00 | 937454.26 | 0.00 | 0.143227E+10 | 0.532188E+09 | 0.00 | 0.65 |
April | 0.194472E+10 | 0.00 | 0.00 | 2137079.37 | 0.00 | 0.386865E+09 | 0.116850E+10 | 0.00 | 0.95 |
May | 0.155921E+10 | 1559646.64 | 0.00 | 4496669.83 | 503070.06 | 0.216344E+09 | 0.203150E+10 | 0.00 | 1.28 |
June | 0.893111E+09 | 38425611.33 | 0.00 | 6940141.33 | 606860.32 | 7943661.82 | 0.197368E+10 | 0.00 | 1.67 |
July | 0.501413E+09 | 82844464.76 | 0.00 | 6428064.73 | 1630895.34 | 0.00 | 0.105453E+10 | 0.00 | 1.39 |
August | 0.795990E+09 | 43244074.24 | 0.00 | 5854224.87 | 1971070.09 | 2540380.03 | 0.130214E+10 | 0.00 | 1.45 |
September | 0.145275E+10 | 82850376.56 | 0.00 | 2735039.60 | 1203570.31 | 70288734.40 | 0.111891E+10 | 0.00 | 1.22 |
October | 0.190933E+10 | 0.00 | 0.00 | 1234428.15 | 0.00 | 0.407739E+09 | 0.707077E+09 | 0.00 | 0.90 |
November | 0.132577E+10 | 0.00 | 0.00 | 213022.01 | 0.00 | 0.139961E+10 | 0.212812E+09 | 0.00 | 0.62 |
December | 0.694675E+09 | 0.00 | 0.00 | 3628.62 | 0.00 | 0.293492E+10 | 9699718.89 | 0.00 | 0.52 |
Annual Sum or Average | 0.142578E+11 | 0.248924E+09 | 0.00 | 31251234.83 | 5915466.12 | 0.131496E+11 | 0.102843E+11 | 0.00 | 0.98 |
Minimum of Months | 0.419265E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.52 |
Maximum of Months | 0.194472E+10 | 82850376.56 | 0.00 | 6940141.33 | 1971070.09 | 0.401317E+10 | 0.203150E+10 | 0.00 | 1.67 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 89487589.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.446884E+10 | 0.00 | 0.00 | 0.31 |
February | 0.686851E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.248279E+10 | 0.00 | 0.00 | 0.31 |
March | 0.151680E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151703E+10 | 0.00 | 0.00 | 0.31 |
April | 0.204360E+10 | 0.00 | 0.00 | 16600.23 | 0.00 | 0.322994E+09 | 9012302.04 | 0.00 | 0.37 |
May | 0.183593E+10 | 1391929.32 | 0.00 | 864677.51 | 1718931.24 | 96292036.77 | 0.419191E+09 | 0.00 | 0.46 |
June | 0.630932E+09 | 33109040.82 | 0.00 | 4073066.47 | 5820017.79 | 0.00 | 0.141212E+10 | 0.00 | 0.70 |
July | 0.289192E+09 | 84046105.81 | 0.00 | 4425209.08 | 3391291.59 | 0.00 | 0.965055E+09 | 0.00 | 0.67 |
August | 0.518021E+09 | 43763244.77 | 0.00 | 4139301.28 | 3743876.89 | 0.00 | 0.119698E+10 | 0.00 | 0.69 |
September | 0.126117E+10 | 49619921.77 | 0.00 | 2098069.46 | 3192488.77 | 466310.22 | 0.864585E+09 | 0.00 | 0.59 |
October | 0.204412E+10 | 0.00 | 0.00 | 433647.40 | 0.00 | 55380288.76 | 0.329455E+09 | 0.00 | 0.41 |
November | 0.172725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.903132E+09 | 0.00 | 0.00 | 0.32 |
December | 0.630742E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.278625E+10 | 0.00 | 0.00 | 0.28 |
Annual Sum or Average | 0.132741E+11 | 0.211930E+09 | 0.00 | 16050571.44 | 17866606.27 | 0.126332E+11 | 0.519640E+10 | 0.00 | 0.45 |
Minimum of Months | 89487589.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.28 |
Maximum of Months | 0.204412E+10 | 84046105.81 | 0.00 | 4425209.08 | 5820017.79 | 0.446884E+10 | 0.141212E+10 | 0.00 | 0.70 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.492379E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.352230E+10 | 0.00 | 0.00 | 0.43 |
February | 0.964580E+09 | 0.00 | 0.00 | 69788.74 | 0.00 | 0.183801E+10 | 44283591.99 | 0.00 | 0.44 |
March | 0.177515E+10 | 0.00 | 0.00 | 296981.30 | 0.00 | 0.883447E+09 | 0.191289E+09 | 0.00 | 0.46 |
April | 0.150814E+10 | 0.00 | 0.00 | 1383565.71 | 0.00 | 0.146984E+09 | 0.832703E+09 | 0.00 | 0.62 |
May | 0.117361E+10 | 2529179.30 | 0.00 | 2849588.90 | 524380.45 | 60398283.45 | 0.143234E+10 | 0.00 | 0.85 |
June | 0.409406E+09 | 37263089.44 | 0.00 | 6884226.81 | 5395925.26 | 0.00 | 0.231070E+10 | 0.00 | 1.49 |
July | 0.171915E+09 | 84977256.42 | 0.00 | 8163735.25 | 2428504.03 | 0.00 | 0.175242E+10 | 0.00 | 1.52 |
August | 0.320063E+09 | 49912416.46 | 0.00 | 7210933.71 | 3512877.09 | 0.00 | 0.217020E+10 | 0.00 | 1.54 |
September | 0.778190E+09 | 43033978.37 | 0.00 | 3816605.65 | 2711973.17 | 219858.71 | 0.170985E+10 | 0.00 | 1.09 |
October | 0.143343E+10 | 0.00 | 0.00 | 1719564.26 | 0.00 | 25276229.22 | 0.102406E+10 | 0.00 | 0.70 |
November | 0.170738E+10 | 0.00 | 0.00 | 103936.97 | 0.00 | 0.667557E+09 | 0.100685E+09 | 0.00 | 0.48 |
December | 0.928806E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.214984E+10 | 0.00 | 0.00 | 0.40 |
Annual Sum or Average | 0.116631E+11 | 0.217716E+09 | 0.00 | 32498927.30 | 14573660.02 | 0.929404E+10 | 0.115685E+11 | 0.00 | 0.84 |
Minimum of Months | 0.171915E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.40 |
Maximum of Months | 0.177515E+10 | 84977256.42 | 0.00 | 8163735.25 | 5395925.26 | 0.352230E+10 | 0.231070E+10 | 0.00 | 1.54 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.693905E+09 | 0.00 | 0.00 | 34759.52 | 0.00 | 0.637524E+10 | 43857193.57 | 0.00 | 0.48 |
February | 0.969038E+09 | 0.00 | 0.00 | 1276505.94 | 0.00 | 0.351123E+10 | 0.682287E+09 | 0.00 | 0.54 |
March | 0.152172E+10 | 0.00 | 0.00 | 1197266.79 | 0.00 | 0.242907E+10 | 0.776117E+09 | 0.00 | 0.49 |
April | 0.144513E+10 | 0.00 | 0.00 | 1288577.62 | 0.00 | 0.129245E+10 | 0.833716E+09 | 0.00 | 0.57 |
May | 0.169758E+10 | 4084727.81 | 0.00 | 2069786.86 | 1054071.83 | 0.887746E+09 | 0.819450E+09 | 0.00 | 0.69 |
June | 0.112048E+10 | 58742949.78 | 0.00 | 4355665.23 | 6679470.08 | 0.161391E+09 | 0.121316E+10 | 0.00 | 0.90 |
July | 0.488193E+09 | 0.151444E+09 | 0.00 | 6181402.56 | 3868772.83 | 19425661.39 | 0.108142E+10 | 0.00 | 0.93 |
August | 0.642897E+09 | 0.102087E+09 | 0.00 | 8133855.83 | 3411344.51 | 0.110223E+09 | 0.183976E+10 | 0.00 | 1.21 |
September | 0.102900E+10 | 0.125954E+09 | 0.00 | 6861759.19 | 1224136.36 | 0.283696E+09 | 0.248949E+10 | 0.00 | 1.20 |
October | 0.140678E+10 | 0.00 | 0.00 | 6272935.29 | 0.00 | 0.532933E+09 | 0.281582E+10 | 0.00 | 0.95 |
November | 0.157322E+10 | 0.00 | 0.00 | 1835145.66 | 0.00 | 0.155065E+10 | 0.121326E+10 | 0.00 | 0.54 |
December | 0.116138E+10 | 0.00 | 0.00 | 240149.37 | 0.00 | 0.412723E+10 | 0.219092E+09 | 0.00 | 0.43 |
Annual Sum or Average | 0.137493E+11 | 0.442313E+09 | 0.00 | 39747809.86 | 16237795.62 | 0.212813E+11 | 0.140274E+11 | 0.00 | 0.75 |
Minimum of Months | 0.488193E+09 | 0.00 | 0.00 | 34759.52 | 0.00 | 19425661.39 | 43857193.57 | 0.00 | 0.43 |
Maximum of Months | 0.169758E+10 | 0.151444E+09 | 0.00 | 8133855.83 | 6679470.08 | 0.637524E+10 | 0.281582E+10 | 0.00 | 1.21 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.367668E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.396229E+10 | 0.00 | 0.00 | 0.47 |
February | 0.999131E+09 | 0.00 | 0.00 | 151365.30 | 0.00 | 0.199439E+10 | 95007964.69 | 0.00 | 0.49 |
March | 0.181964E+10 | 0.00 | 0.00 | 383316.54 | 0.00 | 0.108930E+10 | 0.224172E+09 | 0.00 | 0.51 |
April | 0.189731E+10 | 0.00 | 0.00 | 921285.49 | 0.00 | 0.194539E+09 | 0.515241E+09 | 0.00 | 0.67 |
May | 0.142352E+10 | 1569041.97 | 0.00 | 2847455.39 | 1755679.29 | 65601979.34 | 0.124527E+10 | 0.00 | 0.90 |
June | 0.632583E+09 | 46079379.14 | 0.00 | 4887657.16 | 3205176.06 | 250757.31 | 0.158919E+10 | 0.00 | 1.24 |
July | 0.280185E+09 | 0.106921E+09 | 0.00 | 5483234.84 | 1618166.34 | 0.00 | 0.103277E+10 | 0.00 | 1.13 |
August | 0.526239E+09 | 56043661.03 | 0.00 | 4975609.62 | 1967459.65 | 0.00 | 0.127297E+10 | 0.00 | 1.20 |
September | 0.109512E+10 | 69101105.24 | 0.00 | 2921738.17 | 1026526.28 | 476279.20 | 0.122533E+10 | 0.00 | 1.05 |
October | 0.182630E+10 | 0.00 | 0.00 | 1361154.66 | 0.00 | 38409794.14 | 0.800314E+09 | 0.00 | 0.75 |
November | 0.177514E+10 | 0.00 | 0.00 | 237066.90 | 0.00 | 0.715363E+09 | 0.212557E+09 | 0.00 | 0.52 |
December | 0.909059E+09 | 0.00 | 0.00 | 2729.02 | 0.00 | 0.241135E+10 | 6769875.87 | 0.00 | 0.43 |
Annual Sum or Average | 0.135519E+11 | 0.279714E+09 | 0.00 | 24172613.11 | 9573007.62 | 0.104720E+11 | 0.821959E+10 | 0.00 | 0.78 |
Minimum of Months | 0.280185E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.43 |
Maximum of Months | 0.189731E+10 | 0.106921E+09 | 0.00 | 5483234.84 | 3205176.06 | 0.396229E+10 | 0.158919E+10 | 0.00 | 1.24 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.321700E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401916E+10 | 0.00 | 0.00 | 0.30 |
February | 0.929516E+09 | 0.00 | 0.00 | 1304.31 | 0.00 | 0.204794E+10 | 5447819.06 | 0.00 | 0.30 |
March | 0.208107E+10 | 0.00 | 0.00 | 17922.92 | 0.00 | 0.873819E+09 | 40230079.09 | 0.00 | 0.31 |
April | 0.186917E+10 | 0.00 | 0.00 | 758348.27 | 0.00 | 0.106492E+09 | 0.517932E+09 | 0.00 | 0.40 |
May | 0.130947E+10 | 4032232.08 | 0.00 | 2836979.05 | 1297044.18 | 60101681.31 | 0.132987E+10 | 0.00 | 0.58 |
June | 0.434203E+09 | 47918679.51 | 0.00 | 6433070.69 | 4615169.53 | 0.00 | 0.221606E+10 | 0.00 | 0.94 |
July | 0.238764E+09 | 0.101255E+09 | 0.00 | 5969690.00 | 3158799.88 | 0.00 | 0.126959E+10 | 0.00 | 0.82 |
August | 0.422752E+09 | 58719909.05 | 0.00 | 5542567.18 | 3860459.83 | 0.00 | 0.153236E+10 | 0.00 | 0.82 |
September | 0.109425E+10 | 63162290.90 | 0.00 | 2689005.26 | 3156836.36 | 4124944.35 | 0.108423E+10 | 0.00 | 0.62 |
October | 0.182945E+10 | 0.00 | 0.00 | 728837.17 | 0.00 | 99393872.92 | 0.472346E+09 | 0.00 | 0.42 |
November | 0.161333E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.923604E+09 | 0.00 | 0.00 | 0.32 |
December | 0.690757E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.262320E+10 | 0.00 | 0.00 | 0.28 |
Annual Sum or Average | 0.128344E+11 | 0.275088E+09 | 0.00 | 24977724.84 | 16088309.78 | 0.107578E+11 | 0.846807E+10 | 0.00 | 0.51 |
Minimum of Months | 0.238764E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.28 |
Maximum of Months | 0.208107E+10 | 0.101255E+09 | 0.00 | 6433070.69 | 4615169.53 | 0.401916E+10 | 0.221606E+10 | 0.00 | 0.94 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.694426E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.373316E+10 | 0.00 | 0.00 | 0.50 |
February | 0.127161E+10 | 0.00 | 0.00 | 175160.41 | 0.00 | 0.194791E+10 | 0.121812E+09 | 0.00 | 0.54 |
March | 0.222194E+10 | 0.00 | 0.00 | 918917.09 | 0.00 | 0.811670E+09 | 0.519902E+09 | 0.00 | 0.58 |
April | 0.177826E+10 | 0.00 | 0.00 | 2730412.87 | 0.00 | 82275825.18 | 0.154238E+10 | 0.00 | 0.86 |
May | 0.131047E+10 | 4363930.06 | 0.00 | 4424168.43 | 818857.98 | 68904323.86 | 0.219986E+10 | 0.00 | 1.15 |
June | 0.485166E+09 | 39736713.33 | 0.00 | 8892317.62 | 5251441.20 | 0.00 | 0.288900E+10 | 0.00 | 1.81 |
July | 0.234254E+09 | 84243640.49 | 0.00 | 9684037.13 | 3031466.48 | 0.00 | 0.201639E+10 | 0.00 | 1.75 |
August | 0.501009E+09 | 56006093.47 | 0.00 | 7633914.80 | 4441765.40 | 0.00 | 0.231449E+10 | 0.00 | 1.71 |
September | 0.110354E+10 | 51205049.51 | 0.00 | 3853863.04 | 3501146.60 | 4827288.88 | 0.170958E+10 | 0.00 | 1.21 |
October | 0.189303E+10 | 0.00 | 0.00 | 1549026.06 | 0.00 | 83547081.28 | 0.909308E+09 | 0.00 | 0.80 |
November | 0.189977E+10 | 0.00 | 0.00 | 117162.29 | 0.00 | 0.928474E+09 | 89330766.78 | 0.00 | 0.58 |
December | 0.110290E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.251665E+10 | 0.00 | 0.00 | 0.49 |
Annual Sum or Average | 0.144964E+11 | 0.235555E+09 | 0.00 | 39978979.74 | 17044677.65 | 0.101774E+11 | 0.143121E+11 | 0.00 | 1.00 |
Minimum of Months | 0.234254E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.49 |
Maximum of Months | 0.222194E+10 | 84243640.49 | 0.00 | 9684037.13 | 5251441.20 | 0.373316E+10 | 0.288900E+10 | 0.00 | 1.81 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.139384E+10 | 0.00 | 0.00 | 1582011.07 | 0.00 | 0.344550E+10 | 0.956303E+09 | 0.00 | 0.42 |
February | 0.159845E+10 | 0.00 | 0.00 | 4120972.79 | 0.00 | 0.157867E+10 | 0.201320E+10 | 0.00 | 0.62 |
March | 0.227005E+10 | 0.00 | 0.00 | 6258329.32 | 0.00 | 0.842966E+09 | 0.287044E+10 | 0.00 | 0.68 |
April | 0.196538E+10 | 0.00 | 0.00 | 5674440.30 | 0.00 | 0.122796E+09 | 0.285005E+10 | 0.00 | 0.88 |
May | 0.159916E+10 | 10452279.25 | 0.00 | 6420778.75 | 1015739.06 | 98245718.46 | 0.292367E+10 | 0.00 | 1.02 |
June | 0.802859E+09 | 72847435.38 | 0.00 | 8320109.91 | 3342529.55 | 0.00 | 0.274912E+10 | 0.00 | 1.28 |
July | 0.449315E+09 | 0.151024E+09 | 0.00 | 8220694.51 | 3915914.01 | 0.00 | 0.158927E+10 | 0.00 | 1.14 |
August | 0.643335E+09 | 0.120861E+09 | 0.00 | 10092714.03 | 3536206.90 | 0.00 | 0.252843E+10 | 0.00 | 1.44 |
September | 0.111786E+10 | 0.155721E+09 | 0.00 | 8845316.60 | 1900157.02 | 4197840.08 | 0.342066E+10 | 0.00 | 1.42 |
October | 0.154317E+10 | 0.00 | 0.00 | 9711773.53 | 0.00 | 71504214.71 | 0.416168E+10 | 0.00 | 1.16 |
November | 0.176127E+10 | 0.00 | 0.00 | 5222618.54 | 0.00 | 0.739639E+09 | 0.254703E+10 | 0.00 | 0.66 |
December | 0.162656E+10 | 0.00 | 0.00 | 2251610.27 | 0.00 | 0.219537E+10 | 0.113934E+10 | 0.00 | 0.44 |
Annual Sum or Average | 0.167712E+11 | 0.510905E+09 | 0.00 | 76721369.61 | 13710546.54 | 0.909888E+10 | 0.297492E+11 | 0.00 | 0.93 |
Minimum of Months | 0.449315E+09 | 0.00 | 0.00 | 1582011.07 | 0.00 | 0.00 | 0.956303E+09 | 0.00 | 0.42 |
Maximum of Months | 0.227005E+10 | 0.155721E+09 | 0.00 | 10092714.03 | 3915914.01 | 0.344550E+10 | 0.416168E+10 | 0.00 | 1.44 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.741874E+09 | 0.00 | 0.00 | 199.31 | 0.00 | 0.388402E+10 | 2057689.05 | 0.00 | 0.52 |
February | 0.132353E+10 | 0.00 | 0.00 | 358365.84 | 0.00 | 0.202026E+10 | 0.201503E+09 | 0.00 | 0.58 |
March | 0.228222E+10 | 0.00 | 0.00 | 1061462.12 | 0.00 | 0.972152E+09 | 0.569694E+09 | 0.00 | 0.64 |
April | 0.211671E+10 | 0.00 | 0.00 | 2305150.41 | 0.00 | 0.142068E+09 | 0.117286E+10 | 0.00 | 0.93 |
May | 0.150513E+10 | 3171793.28 | 0.00 | 4724803.21 | 2249745.25 | 75049833.26 | 0.201556E+10 | 0.00 | 1.21 |
June | 0.745009E+09 | 54899725.84 | 0.00 | 6329167.17 | 4066283.14 | 291746.16 | 0.197508E+10 | 0.00 | 1.54 |
July | 0.417828E+09 | 0.122252E+09 | 0.00 | 6342505.80 | 1596931.32 | 0.00 | 0.106668E+10 | 0.00 | 1.30 |
August | 0.692334E+09 | 68141804.52 | 0.00 | 5445906.17 | 2351847.32 | 0.00 | 0.133625E+10 | 0.00 | 1.37 |
September | 0.136695E+10 | 90346885.10 | 0.00 | 3055488.59 | 663225.66 | 7288877.18 | 0.126938E+10 | 0.00 | 1.19 |
October | 0.216151E+10 | 0.00 | 0.00 | 1591306.06 | 0.00 | 0.103730E+09 | 0.836814E+09 | 0.00 | 0.88 |
November | 0.183197E+10 | 0.00 | 0.00 | 356732.54 | 0.00 | 0.989947E+09 | 0.280983E+09 | 0.00 | 0.62 |
December | 0.105268E+10 | 0.00 | 0.00 | 13502.20 | 0.00 | 0.272450E+10 | 19672694.71 | 0.00 | 0.51 |
Annual Sum or Average | 0.162377E+11 | 0.338812E+09 | 0.00 | 31584589.42 | 10928032.69 | 0.109193E+11 | 0.107465E+11 | 0.00 | 0.94 |
Minimum of Months | 0.417828E+09 | 0.00 | 0.00 | 199.31 | 0.00 | 0.00 | 2057689.05 | 0.00 | 0.51 |
Maximum of Months | 0.228222E+10 | 0.122252E+09 | 0.00 | 6342505.80 | 4066283.14 | 0.388402E+10 | 0.201556E+10 | 0.00 | 1.54 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2024-07-03 12:20:12
Custom Monthly ReportSITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
January | 0.150046E+12 | 0.173693E+11 | 0.00 | 0.163666E+12 | 0.512208E+11 |
February | 0.200827E+12 | 0.134001E+11 | 0.00 | 0.160389E+12 | 0.312371E+11 |
March | 0.326404E+12 | 0.128310E+11 | 0.00 | 0.191744E+12 | 0.214979E+11 |
April | 0.344680E+12 | 0.880689E+10 | 0.00 | 0.217458E+12 | 0.147017E+11 |
May | 0.452329E+12 | 0.849745E+10 | 0.00 | 0.225585E+12 | 0.337240E+11 |
June | 0.487855E+12 | 0.408999E+10 | 0.00 | 0.204186E+12 | 0.105640E+12 |
July | 0.484778E+12 | 0.207856E+10 | 0.00 | 0.173218E+12 | 0.179822E+12 |
August | 0.406730E+12 | 0.300127E+10 | 0.00 | 0.197577E+12 | 0.151010E+12 |
September | 0.312106E+12 | 0.559778E+10 | 0.00 | 0.204109E+12 | 0.710590E+11 |
October | 0.210087E+12 | 0.853657E+10 | 0.00 | 0.233420E+12 | 0.190349E+11 |
November | 0.119968E+12 | 0.117850E+11 | 0.00 | 0.188054E+12 | 0.183291E+11 |
December | 0.984359E+11 | 0.149172E+11 | 0.00 | 0.162680E+12 | 0.382132E+11 |
Annual Sum or Average | 0.359425E+13 | 0.110911E+12 | 0.00 | 0.232209E+13 | 0.735490E+12 |
Minimum of Months | 0.984359E+11 | 0.207856E+10 | 0.00 | 0.160389E+12 | 0.147017E+11 |