Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2024.07.03 12:20
Tabular Output Report in Format: HTML
Building: OfficeMedium
Environment: RUNPERIOD 1 ** William R Fairchild WA USA TMY3 WMO#=727885
Simulation Timestamp: 2024-07-03 12:20:09
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1538.32 | 308.76 | 308.76 |
Net Site Energy | 1538.32 | 308.76 | 308.76 |
Total Source Energy | 4322.24 | 867.54 | 867.54 |
Net Source Energy | 4322.24 | 867.54 | 867.54 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 1.200 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil No 1 | 1.050 |
Fuel Oil No 2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4982.19 |
Net Conditioned Building Area | 4982.19 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 263.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 38.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 303.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 51.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 719.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 26.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 75.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 1.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 56.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1274.46 | 263.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler | 0.00 | 263.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 38.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 303.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 51.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | ElevatorLift | 134.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLightsFan | 0.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
MiscPlug | 584.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 26.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 75.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 1.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 | |
Water Heater | 56.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Unassigned | 0.00 | 263.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | Unassigned | 38.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GENERAL | 303.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | Unassigned | 51.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | GENERAL | 719.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | Unassigned | 26.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Unassigned | 75.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | Unassigned | 1.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Unassigned | 56.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 71.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 34.55 | 52.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Other | 149.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 255.80 | 52.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 71.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 34.55 | 52.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Other | 149.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 255.80 | 52.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1274.458 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1274.458 | 100.00 |
Total On-Site and Utility Electric Sources | 1274.458 | 100.00 |
Total Electricity End Uses | 1274.458 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 271.06 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 271.06 | 100.00 |
Total Water End Uses | 271.06 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 378.17 |
Time Setpoint Not Met During Occupied Cooling | 72.17 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 1952.33 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5C
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2016
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICEMEDIUM
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_WA_PORTANGELES
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PERFORMANCEPATHPROPOSED
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |ZoneCoolingSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ZoneHeatingSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ZoneElectricSummaryMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |SpaceGainsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | FIRSTFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM |PeakSpaceGainsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | FIRSTFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM |SpaceGainComponentsAtCoolingPeakMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ComfortReportSimple55Monthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |OccupantComfortDataSummaryMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |BoilerReportMonthly
| HEATSYS1 BOILER |DXReportMonthly
| PACU_VAV_BOT COOLING COIL | PACU_VAV_MID COOLING COIL | PACU_VAV_TOP COOLING COIL |WindowReportMonthly
| PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW |WindowEnergyReportMonthly
| PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW |WindowZoneSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |WindowEnergyZoneSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWHSYS1 WATER HEATER |DaylightingReportMonthly
| PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_4_DAYLCTRL |CoilReportMonthly
| PACU_VAV_BOT HEATING COIL | CORE_BOTTOM VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | PACU_VAV_MID HEATING COIL | CORE_MID VAV BOX REHEAT COIL | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | PACU_VAV_TOP HEATING COIL | CORE_TOP VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | PACU_VAV_BOT COOLING COIL | PACU_VAV_MID COOLING COIL | PACU_VAV_TOP COOLING COIL |PlantLoopDemandReportMonthly
| HEATSYS1 | SWHSYS1 |FanReportMonthly
| PACU_VAV_BOT FAN | PACU_VAV_MID FAN | PACU_VAV_TOP FAN |PumpReportMonthly
| HEATSYS1 PUMP | SWHSYS1 PUMP |CondLoopDemandReportMonthly
| HEATSYS1 | SWHSYS1 |ZoneTemperatureOscillationReportMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |AirLoopSystemEnergyAndWaterUseMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |AirLoopSystemComponentLoadsMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |AirLoopSystemComponentEnergyUseMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |MechanicalVentilationLoadsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
GeneralValue | |
Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2024.07.03 12:20 |
RunPeriod | RUNPERIOD 1 |
Weather File | William R Fairchild WA USA TMY3 WMO#=727885 |
Latitude [deg] | 48.12 |
Longitude [deg] | -123.5 |
Elevation [m] | 91.00 |
Time Zone | -8.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Above Ground Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Window Opening Area [m2] | 652.62 | 195.79 | 130.53 | 195.79 | 130.53 |
Gross Window-Wall Ratio [%] | 33.00 | 33.00 | 33.00 | 33.00 | 33.00 |
Above Ground Window-Wall Ratio [%] | 33.00 | 33.00 | 33.00 | 33.00 | 33.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Above Ground Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Window Opening Area [m2] | 652.62 | 195.79 | 130.53 | 195.79 | 130.53 |
Gross Window-Wall Ratio [%] | 33.00 | 33.00 | 33.00 | 33.00 | 33.00 |
Above Ground Window-Wall Ratio [%] | 33.00 | 33.00 | 33.00 | 33.00 | 33.00 |
Total | |
Gross Roof Area [m2] | 1660.73 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
CORE_BOTTOM | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.6994 | 18.58 | 89.4590 |
TOPFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
MIDFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
FIRSTFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
CORE_MID | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.6994 | 18.58 | 8.0700 |
CORE_TOP | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.6994 | 18.58 | 8.0700 |
PERIMETER_TOP_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 8.6994 | 18.58 | 8.0700 |
PERIMETER_TOP_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 8.6994 | 18.58 | 8.0695 |
PERIMETER_TOP_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 8.6994 | 18.58 | 8.0699 |
PERIMETER_TOP_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 8.6994 | 18.58 | 8.0700 |
PERIMETER_BOT_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 8.6994 | 18.58 | 8.0700 |
PERIMETER_BOT_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 8.6994 | 18.58 | 8.0695 |
PERIMETER_BOT_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 8.6994 | 18.58 | 8.0699 |
PERIMETER_BOT_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 8.6994 | 18.58 | 8.0700 |
PERIMETER_MID_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 8.6994 | 18.58 | 8.0700 |
PERIMETER_MID_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 8.6994 | 18.58 | 8.0695 |
PERIMETER_MID_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 8.6994 | 18.58 | 8.0699 |
PERIMETER_MID_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 8.6994 | 18.58 | 8.0700 |
Total | 4982.19 | 13667.13 | 1369.16 | 0.00 | 652.62 | 652.62 | 8.6994 | 18.58 | 24.1370 | |||
Conditioned Total | 4982.19 | 13667.13 | 1369.16 | 0.00 | 652.62 | 652.62 | 8.6994 | 18.58 | 24.1370 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 4982.19 | 6074.28 | 608.51 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
CORE_BOTTOM | 983.54 | Yes | Yes | 1.00 | CORE_BOTTOM | GENERAL | CORE_BOTTOM | 8.6994 | 18.58 | 89.4590 | |
TOPFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | TOPFLOOR_PLENUM | GENERAL | TOPFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
MIDFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | MIDFLOOR_PLENUM | GENERAL | MIDFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
FIRSTFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | FIRSTFLOOR_PLENUM | GENERAL | FIRSTFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
CORE_MID | 983.54 | Yes | Yes | 1.00 | CORE_MID | GENERAL | CORE_MID | 8.6994 | 18.58 | 8.0700 | |
CORE_TOP | 983.54 | Yes | Yes | 1.00 | CORE_TOP | GENERAL | CORE_TOP | 8.6994 | 18.58 | 8.0700 | |
PERIMETER_TOP_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_3 | GENERAL | PERIMETER_TOP_ZN_3 | 8.6994 | 18.58 | 8.0700 | |
PERIMETER_TOP_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_2 | GENERAL | PERIMETER_TOP_ZN_2 | 8.6994 | 18.58 | 8.0695 | |
PERIMETER_TOP_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_1 | GENERAL | PERIMETER_TOP_ZN_1 | 8.6994 | 18.58 | 8.0699 | |
PERIMETER_TOP_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_4 | GENERAL | PERIMETER_TOP_ZN_4 | 8.6994 | 18.58 | 8.0700 | |
PERIMETER_BOT_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_3 | GENERAL | PERIMETER_BOT_ZN_3 | 8.6994 | 18.58 | 8.0700 | |
PERIMETER_BOT_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_2 | GENERAL | PERIMETER_BOT_ZN_2 | 8.6994 | 18.58 | 8.0695 | |
PERIMETER_BOT_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_1 | GENERAL | PERIMETER_BOT_ZN_1 | 8.6994 | 18.58 | 8.0699 | |
PERIMETER_BOT_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_4 | GENERAL | PERIMETER_BOT_ZN_4 | 8.6994 | 18.58 | 8.0700 | |
PERIMETER_MID_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_3 | GENERAL | PERIMETER_MID_ZN_3 | 8.6994 | 18.58 | 8.0700 | |
PERIMETER_MID_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_2 | GENERAL | PERIMETER_MID_ZN_2 | 8.6994 | 18.58 | 8.0695 | |
PERIMETER_MID_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_1 | GENERAL | PERIMETER_MID_ZN_1 | 8.6994 | 18.58 | 8.0699 | |
PERIMETER_MID_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_4 | GENERAL | PERIMETER_MID_ZN_4 | 8.6994 | 18.58 | 8.0700 | |
Total | 4982.19 | 8.6994 | 9.29 | 24.1370 | |||||||
Conditioned Total | 4982.19 | 8.6994 | 9.29 | 24.1370 | |||||||
Unconditioned Total | 0.00 | 0.0000 | 0.00 | 0.0000 | |||||||
Not Part of Total | 4982.19 | 0.0000 | 0.00 | 0.0000 |
Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
GENERAL | 4982.19 | 4982.19 | 0.00 | 4982.19 | 8.6994 | 18.58 | 24.1370 |
Total | 4982.19 | 4982.19 | 0.00 | 4982.19 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
End UsesElectricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 13-JUN-15:30 | 10-JAN-07:10 | - | - | - | - | - | - | - | - | - | - | 03-JAN-12:20 |
Heating | 0.00 | 174236.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 41522.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 25681.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 41670.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 1410.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 22047.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 6.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 4629.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 136967.67 | 174236.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler | 0.00 | 174236.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 41522.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 25681.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | ElevatorLift | 7125.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLightsFan | 57.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
MiscPlug | 34487.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 1410.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 22047.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 6.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Water Heater | 4629.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 286.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 121.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 962.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 163.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 2279.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 85.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 240.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 4.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 179.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4036.21 | 286.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 57.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 24.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 193.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 32.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 457.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 17.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 48.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 35.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 810.13 | 57.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 57.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 24.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 193.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 32.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 457.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 17.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 48.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 35.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 810.13 | 57.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
AirTerminal:SingleDuct:VAV:ReheatDesign Size Maximum Air Flow Rate [m3/s] | Design Size Constant Minimum Air Flow Fraction | User-Specified Constant Minimum Air Flow Fraction | Design Size Minimum Air Flow Rate [m3/s] | Design Size Maximum Flow Fraction during Reheat [] | User-Specified Maximum Flow Fraction during Reheat [] | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | Design Size Maximum Reheat Water Flow Rate [m3/s] | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | |
CORE_BOTTOM VAV BOX COMPONENT | 2.71 | 0.276737 | 0.285000 | 0.771833 | 0.737965 | 0.500000 | 0.001377 | 0.000113 | 0.771833 | 12.80 | 0.008000 |
CORE_MID VAV BOX COMPONENT | 2.18 | 0.344179 | 0.348000 | 0.757774 | 0.917811 | 0.500000 | 0.001107 | 0.000168 | 0.757774 | 12.80 | 0.008000 |
CORE_TOP VAV BOX COMPONENT | 2.19 | 0.341756 | 0.356000 | 0.780691 | 0.911349 | 0.500000 | 0.001115 | 0.000265 | 0.910795 | 12.80 | 0.008000 |
PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | 0.588494 | 0.268468 | 0.280000 | 0.164778 | 0.715915 | 0.500000 | 0.001419 | 0.000116 | 0.399048 | 12.80 | 0.008000 |
PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | 0.786818 | 0.127122 | 0.200000 | 0.157364 | 0.338992 | 0.500000 | 0.002997 | 0.000076 | 0.261794 | 12.80 | 0.008000 |
PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | 1.18 | 0.134039 | 0.200000 | 0.235740 | 0.357437 | 0.500000 | 0.002842 | 0.000116 | 0.400222 | 12.80 | 0.008000 |
PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | 0.869257 | 0.115058 | 0.200000 | 0.173851 | 0.306822 | 0.500000 | 0.003311 | 0.000076 | 0.260789 | 12.80 | 0.008000 |
PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | 0.468349 | 0.337338 | 0.348000 | 0.162985 | 0.899567 | 0.500000 | 0.001129 | 0.000090 | 0.309849 | 12.80 | 0.008000 |
PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | 0.644469 | 0.155200 | 0.200000 | 0.128894 | 0.413867 | 0.500000 | 0.002455 | 0.000060 | 0.206549 | 12.80 | 0.008000 |
PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | 0.963745 | 0.163935 | 0.200000 | 0.192749 | 0.437160 | 0.500000 | 0.002324 | 0.000090 | 0.311414 | 12.80 | 0.008000 |
PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | 0.723584 | 0.138222 | 0.200000 | 0.144717 | 0.368592 | 0.500000 | 0.002756 | 0.000060 | 0.205526 | 12.80 | 0.008000 |
PERIMETER_MID_ZN_3 VAV BOX COMPONENT | 0.525787 | 0.300486 | 0.304000 | 0.159839 | 0.801296 | 0.500000 | 0.001268 | 0.000088 | 0.304289 | 12.80 | 0.008000 |
PERIMETER_MID_ZN_2 VAV BOX COMPONENT | 0.792379 | 0.126230 | 0.200000 | 0.158476 | 0.336613 | 0.500000 | 0.003018 | 0.000059 | 0.201814 | 12.80 | 0.008000 |
PERIMETER_MID_ZN_1 VAV BOX COMPONENT | 1.11 | 0.142934 | 0.200000 | 0.221069 | 0.381158 | 0.500000 | 0.002666 | 0.000089 | 0.305384 | 12.80 | 0.008000 |
PERIMETER_MID_ZN_4 VAV BOX COMPONENT | 0.816224 | 0.122534 | 0.200000 | 0.163245 | 0.326757 | 0.500000 | 0.003109 | 0.000058 | 0.200800 | 12.80 | 0.008000 |
Design Size Rated Capacity [W] | Design Size Maximum Water Flow Rate [m3/s] | Design Size U-Factor Times Area Value [W/K] | |
CORE_BOTTOM VAV BOX REHEAT COIL | 12896.73 | 0.000113 | 278.63 |
CORE_MID VAV BOX REHEAT COIL | 19181.53 | 0.000168 | 457.10 |
CORE_TOP VAV BOX REHEAT COIL | 30300.54 | 0.000265 | 800.19 |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | 13241.80 | 0.000116 | 349.29 |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | 8686.52 | 0.000076 | 229.12 |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | 13280.65 | 0.000116 | 350.31 |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | 8653.23 | 0.000076 | 228.24 |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | 10287.83 | 0.000090 | 271.44 |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | 6857.07 | 0.000060 | 180.91 |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | 10339.69 | 0.000090 | 272.81 |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | 6823.23 | 0.000060 | 180.02 |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | 10104.19 | 0.000088 | 266.61 |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | 6700.53 | 0.000059 | 176.79 |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | 10140.47 | 0.000089 | 267.56 |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | 6666.98 | 0.000058 | 175.90 |
PACU_VAV_BOT HEATING COIL | 22102.57 | 0.000193 | 370.78 |
PACU_VAV_MID HEATING COIL | 23023.16 | 0.000201 | 382.82 |
PACU_VAV_TOP HEATING COIL | 22418.10 | 0.000196 | 376.87 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PACU_VAV_BOT | 2.75 | 1.40 | 5.51 | 1.46 | 4.79 | 4.79 | 0.300000 | 0.304599 | 4.79 |
PACU_VAV_MID | 2.71 | 1.46 | 5.42 | 1.51 | 4.47 | 4.47 | 0.300000 | 0.337139 | 4.47 |
PACU_VAV_TOP | 2.81 | 1.51 | 5.62 | 2.23 | 4.99 | 4.99 | 0.300000 | 0.447313 | 4.99 |
Maximum Outdoor Air Flow Rate [m3/s] | |
PACU_VAV_BOT_OA_CONTROLLER | 4.79 |
PACU_VAV_MID_OA_CONTROLLER | 4.47 |
PACU_VAV_TOP_OA_CONTROLLER | 4.99 |
Design Size High Speed Rated Air Flow Rate [m3/s] | Design Size High Speed Gross Rated Total Cooling Capacity [W] | Design Size High Speed Rated Sensible Heat Ratio | Design Size Low Speed Rated Air Flow Rate [m3/s] | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | Design Size Low Speed Gross Rated Sensible Heat Ratio | |
PACU_VAV_BOT COOLING COIL | 4.79 | 79237.20 | 0.800655 | 1.60 | 26409.76 | 0.800655 |
PACU_VAV_MID COOLING COIL | 4.47 | 74062.64 | 0.800655 | 1.49 | 24685.08 | 0.800655 |
PACU_VAV_TOP COOLING COIL | 4.99 | 82622.85 | 0.800655 | 1.66 | 27538.20 | 0.800655 |
Design Size Maximum Flow Rate [m3/s] | |
PACU_VAV_BOT FAN | 4.79 |
PACU_VAV_MID FAN | 4.47 |
PACU_VAV_TOP FAN | 4.99 |
Maximum Actuated Flow [m3/s] | |
PACU_VAV_BOT_HEATC_CONTROLLER | 0.000193 |
PACU_VAV_MID_HEATC_CONTROLLER | 0.000201 |
PACU_VAV_TOP_HEATC_CONTROLLER | 0.000196 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
HEATSYS1 | 0.002115 | 0.253745 |
SWHSYS1 | 0.000054 | 0.006435 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | Design Minimum Flow Rate [m3/s] | |
HEATSYS1 PUMP | 0.002115 | 636.81 | 0.000000 |
Design Size Nominal Capacity [W] | User-Specified Nominal Capacity [W] | Design Size Design Water Flow Rate [m3/s] | |
HEATSYS1 BOILER | 241704.83 | 241704.83 | 0.002115 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | |
SWHSYS1 PUMP | 0.000054 | 6.85 |
Use Side Design Flow Rate [m3/s] | |
SWHSYS1 WATER HEATER | 0.000054 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
PERIMETER_TOP_ZN_3_WALL_NORTH | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | |
PERIMETER_TOP_ZN_2_WALL_EAST | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | |
PERIMETER_TOP_ZN_1_WALL_SOUTH | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | |
PERIMETER_TOP_ZN_4_WALL_WEST | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | |
PERIMETER_BOT_ZN_3_WALL_NORTH | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | |
PERIMETER_BOT_ZN_2_WALL_EAST | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | |
PERIMETER_BOT_ZN_1_WALL_SOUTH | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | |
PERIMETER_BOT_ZN_4_WALL_WEST | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | |
PERIMETER_MID_ZN_3_WALL_NORTH | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | |
PERIMETER_MID_ZN_2_WALL_EAST | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | |
PERIMETER_MID_ZN_1_WALL_SOUTH | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | |
PERIMETER_MID_ZN_4_WALL_WEST | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
VersionVersion ID | |
1 | 22.1 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 9.30 | 6.70 | 4.10 | 4.20 | 4.20 | 5.90 | 9.00 | 10.00 | 13.30 | 15.00 | 15.70 | 13.40 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | William R Fairchild WA USA TMY3 WMO#=727885 | 48.12 | -123.50 | -8.00 | 91.00 | 100237 | 1.1914 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 9.23 | 11.60 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | OfficeMedium | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 18 | 167 | 24 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | CORE_BOTTOM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 1.37 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 0.00 | 2.74 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
2 | TOPFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 11.28 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 10.67 | 11.89 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 10 | 0 | 0 | No |
3 | MIDFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 7.32 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 6.71 | 7.92 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 14 | 0 | 0 | No |
4 | FIRSTFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 3.35 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 2.74 | 3.96 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 14 | 0 | 0 | No |
5 | CORE_MID | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 5.33 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 3.96 | 6.71 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
6 | CORE_TOP | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 9.30 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 7.92 | 10.67 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
7 | PERIMETER_TOP_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 9.30 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 7.92 | 10.67 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 71.65 | 65.26 | 6 | 1 | 0 | Yes |
8 | PERIMETER_TOP_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 9.30 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 7.92 | 10.67 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 47.77 | 43.51 | 6 | 1 | 0 | Yes |
9 | PERIMETER_TOP_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 9.30 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 7.92 | 10.67 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 71.65 | 65.26 | 6 | 1 | 0 | Yes |
10 | PERIMETER_TOP_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 9.30 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 7.92 | 10.67 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 47.77 | 43.51 | 6 | 1 | 0 | Yes |
11 | PERIMETER_BOT_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 1.37 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 0.00 | 2.74 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 67.75 | 65.26 | 6 | 5 | 0 | Yes |
12 | PERIMETER_BOT_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 1.37 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 0.00 | 2.74 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 45.82 | 43.51 | 6 | 3 | 0 | Yes |
13 | PERIMETER_BOT_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 1.37 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 0.00 | 2.74 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 67.75 | 65.26 | 6 | 5 | 0 | Yes |
14 | PERIMETER_BOT_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 1.37 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 0.00 | 2.74 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 45.82 | 43.51 | 6 | 3 | 0 | Yes |
15 | PERIMETER_MID_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 5.33 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 3.96 | 6.71 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 71.65 | 65.26 | 6 | 1 | 0 | Yes |
16 | PERIMETER_MID_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 5.33 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 3.96 | 6.71 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 47.77 | 43.51 | 6 | 1 | 0 | Yes |
17 | PERIMETER_MID_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 5.33 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 3.96 | 6.71 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 71.65 | 65.26 | 6 | 1 | 0 | Yes |
18 | PERIMETER_MID_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 5.33 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 3.96 | 6.71 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 47.77 | 43.51 | 6 | 1 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | CORE_BOTTOM | 983.54 | 52.9 | 18.579 | 5.382E-002 | 8.699 | 89.459 | 0.000 | 0.000 | 0.000 | 0.000 | 98.158 | No |
2 | TOPFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
3 | MIDFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
4 | FIRSTFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
5 | CORE_MID | 983.54 | 52.9 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
6 | CORE_TOP | 983.54 | 52.9 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
7 | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
8 | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 8.699 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
9 | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
10 | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
11 | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
12 | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 8.699 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
13 | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
14 | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
15 | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
16 | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 8.699 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
17 | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
18 | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 8.699 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.769 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | Cooling Effect Calculation | Ankle Draft Calculation | |
1 | CORE_BOTTOM | BLDG_OCC_SCH_WO_SB | CORE_BOTTOM | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
2 | CORE_MID | BLDG_OCC_SCH_WO_SB | CORE_MID | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
3 | CORE_TOP | BLDG_OCC_SCH_WO_SB | CORE_TOP | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
4 | PERIMETER_TOP_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
5 | PERIMETER_TOP_ZN_2 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
6 | PERIMETER_TOP_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
7 | PERIMETER_TOP_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
8 | PERIMETER_BOT_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
9 | PERIMETER_BOT_ZN_2 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
10 | PERIMETER_BOT_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
11 | PERIMETER_BOT_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
12 | PERIMETER_MID_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
13 | PERIMETER_MID_ZN_2 | BLDG_OCC_SCH_W_SB | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
14 | PERIMETER_MID_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
15 | PERIMETER_MID_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | CORE_BOTTOM_LIGHTS | LTG_SCH_OFFICE | CORE_BOTTOM | 983.54 | 52.9 | 8556.149 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 8556.149 |
2 | CORE_MID_LIGHTS | LTG_SCH_OFFICE | CORE_MID | 983.54 | 52.9 | 8556.149 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 8556.149 |
3 | CORE_TOP_LIGHTS | LTG_SCH_OFFICE | CORE_TOP | 983.54 | 52.9 | 8556.149 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 8556.149 |
4 | PERIMETER_TOP_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 1803.711 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1803.711 |
5 | PERIMETER_TOP_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 1141.898 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1141.898 |
6 | PERIMETER_TOP_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 1803.711 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1803.711 |
7 | PERIMETER_TOP_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 1141.823 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1141.823 |
8 | PERIMETER_BOT_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 1803.711 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1803.711 |
9 | PERIMETER_BOT_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 1141.898 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1141.898 |
10 | PERIMETER_BOT_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1803.711 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1803.711 |
11 | PERIMETER_BOT_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 1141.823 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1141.823 |
12 | PERIMETER_MID_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 1803.711 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1803.711 |
13 | PERIMETER_MID_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 1141.898 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1141.898 |
14 | PERIMETER_MID_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 1803.711 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1803.711 |
15 | PERIMETER_MID_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 1141.823 | 8.699 | 161.624 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1141.823 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | ELEVATOR_LIFT_RUNNING | ELEVATOR_RUNNING_SCH | CORE_BOTTOM | 983.54 | 52.9 | 76724.000 | 78.008 | 1449.300 | 0.000 | 0.500 | 0.000 | 0.500 | ElevatorLift | 0.000 | 4561.242 |
2 | ELEVATOR_LIFT_STANDBY | ELEVATOR_STANDBY_SCH | CORE_BOTTOM | 983.54 | 52.9 | 3200.000 | 3.254 | 60.447 | 0.000 | 0.500 | 0.000 | 0.500 | ElevatorLift | 2563.936 | 3200.000 |
3 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_ADD_DF | CORE_BOTTOM | 983.54 | 52.9 | 125.000 | 0.127 | 2.361 | 0.000 | 0.500 | 0.000 | 0.500 | ElevatorLightsFan | 0.000 | 86.250 |
4 | CORE_BOTTOM_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_BOTTOM | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
5 | CORE_MID_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_MID | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
6 | CORE_TOP_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_TOP | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
7 | PERIMETER_TOP_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
8 | PERIMETER_TOP_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
9 | PERIMETER_TOP_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
10 | PERIMETER_TOP_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
11 | PERIMETER_BOT_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
12 | PERIMETER_BOT_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
13 | PERIMETER_BOT_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
14 | PERIMETER_BOT_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
15 | PERIMETER_MID_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
16 | PERIMETER_MID_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
17 | PERIMETER_MID_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
18 | PERIMETER_MID_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 3.065 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | INTERIORFURNISHINGS | 2 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
3 | DROPCEILING | 4 | 1 | 3 | 0.167 | 4.488 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 7 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | INT_SLAB_FLOOR | 12 | 2 | 7 | 0.167 | 3.839 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
6 | INT_SLAB_CEILING | 13 | 2 | 7 | 0.167 | 3.839 | 0.900 | 0.900 | 0.700 | 0.700 | VeryRough |
7 | NONRES_ROOF | 17 | 3 | 3 | 0.167 | 0.1864 | 0.900 | 0.900 | 0.700 | 0.700 | Rough |
8 | NONRES_EXT_WALL_GRD | 20 | 4 | 7 | 0.167 | 0.8022 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
9 | NONRES_EXT_WALL_MID | 21 | 4 | 7 | 0.167 | 0.7887 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
10 | NONRES_EXT_WALL_TOP | 22 | 4 | 7 | 0.167 | 1.032 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
11 | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 39 | 2 | 7 | 0.167 | 0.2242 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
12 | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 40 | 2 | 7 | 0.167 | 0.2365 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 41 | 2 | 7 | 0.167 | 0.2242 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 42 | 2 | 7 | 0.167 | 0.2366 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | CORE_BOT_ZN_5_FLOOR_FFACTOR | 43 | 2 | 8 | 0.167 | 0.5650E-02 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.3263 |
2 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
3 | AC02 ACOUSTIC CEILING | 0.0127 | 0.057 | 288.000 | 1339.000 | 0.2228 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
7 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
8 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
9 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
10 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
11 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 5.307 |
12 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
13 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
14 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
15 | NONRES_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 1.013 |
16 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
17 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
18 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
19 | NONRES_EXTERIOR_WALL_INSULATION_MID | 0.0000 | 0.000 | 0.000 | 0.000 | 1.034 |
20 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
21 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
22 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
23 | NONRES_EXTERIOR_WALL_INSULATION_TOP | 0.0000 | 0.000 | 0.000 | 0.000 | 0.7350 |
24 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
25 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.383 |
26 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
27 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.151 |
28 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
29 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.383 |
30 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
31 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.150 |
32 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
33 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 176.9 |
34 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 3.0649134 | 3.0649134 | 3.0649134 | |
3 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
4 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
5 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
6 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
7 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
8 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
9 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
10 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
11 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
12 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
13 | 3 | -0.21589802E-09 | 0.15643069E-09 | -0.21589802E-09 | 0.12999471E-21 |
14 | 2 | 0.50772448E-02 | 0.30006816E-02 | 0.50772448E-02 | -0.13693132E-08 |
15 | 1 | -2.5944910 | 1.4597758 | -2.5944910 | 0.76344767E-02 |
16 | 0 | 7.0433378 | 2.9911476 | 7.0433378 | |
17 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
18 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
19 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
20 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
21 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
22 | 7 | 0.43260499E-16 | 0.34524919E-16 | 0.52793240E-17 | 0.0000000 |
23 | 6 | 0.69434179E-09 | 0.98085174E-11 | 0.18162501E-10 | -0.40870994E-12 |
24 | 5 | -0.12888762E-04 | 0.28373718E-06 | -0.16918523E-06 | 0.92361873E-08 |
25 | 4 | 0.25174112E-01 | 0.33697681E-03 | 0.22646198E-03 | -0.31467795E-04 |
26 | 3 | -3.7600775 | 0.27170599E-01 | -0.48495626E-01 | 0.94171705E-02 |
27 | 2 | 51.553741 | 0.22121684 | 1.2284947 | -0.25833933 |
28 | 1 | -128.86110 | 0.21944682 | -5.1479470 | 1.1228340 |
29 | 0 | 81.526494 | 0.16043334E-01 | 4.4519351 | |
30 | 7 | 0.52793240E-17 | 0.34524919E-16 | 0.43260499E-16 | 0.0000000 |
31 | 6 | 0.18162501E-10 | 0.98085174E-11 | 0.69434179E-09 | -0.40870994E-12 |
32 | 5 | -0.16918523E-06 | 0.28373718E-06 | -0.12888762E-04 | 0.92361873E-08 |
33 | 4 | 0.22646198E-03 | 0.33697681E-03 | 0.25174112E-01 | -0.31467795E-04 |
34 | 3 | -0.48495626E-01 | 0.27170599E-01 | -3.7600775 | 0.94171705E-02 |
35 | 2 | 1.2284947 | 0.22121684 | 51.553741 | -0.25833933 |
36 | 1 | -5.1479470 | 0.21944682 | -128.86110 | 1.1228340 |
37 | 0 | 4.4519351 | 0.16043334E-01 | 81.526494 | |
38 | 3 | -0.62854340E-06 | 0.84784826E-09 | -0.38512804E-05 | 0.91756347E-17 |
39 | 2 | 0.78257096 | 0.11428808E-02 | 1.0614277 | -0.73836085E-06 |
40 | 1 | -21.991499 | 0.76199851E-01 | -6.3161914 | 0.20349372 |
41 | 0 | 21.357363 | 0.71091016E-01 | 5.4032014 | |
42 | 7 | -0.29755900E-12 | 0.81313074E-15 | -0.93602003E-13 | 0.14510957E-15 |
43 | 6 | 0.28367368E-07 | 0.22496401E-09 | 0.65009128E-08 | -0.13359594E-12 |
44 | 5 | -0.18856357E-03 | 0.19286971E-05 | -0.97009749E-04 | 0.64274374E-08 |
45 | 4 | 0.29034011 | 0.94012602E-03 | 0.99033658E-01 | -0.33316087E-04 |
46 | 3 | -7.2305496 | 0.29163423E-01 | -2.3282961 | 0.28833673E-01 |
47 | 2 | 40.753148 | 0.10379063 | 15.221555 | -0.33202618 |
48 | 1 | -80.455373 | 0.46876469E-01 | -29.102648 | 1.0766925 |
49 | 0 | 46.824339 | 0.94379271E-03 | 16.292168 | |
50 | 7 | -0.29905644E-12 | 0.21441847E-14 | -0.94350753E-13 | 0.15229914E-15 |
51 | 6 | 0.28527035E-07 | 0.22156944E-09 | 0.65361533E-08 | -0.13441220E-12 |
52 | 5 | -0.18937502E-03 | 0.18976302E-05 | -0.97416439E-04 | 0.64617957E-08 |
53 | 4 | 0.29129073 | 0.92413897E-03 | 0.99375489E-01 | -0.33450099E-04 |
54 | 3 | -7.2493786 | 0.28644335E-01 | -2.3338831 | 0.28925940E-01 |
55 | 2 | 40.815249 | 0.10187053 | 15.244478 | -0.33271782 |
56 | 1 | -80.502964 | 0.45980673E-01 | -29.123201 | 1.0777067 |
57 | 0 | 46.824339 | 0.92519179E-03 | 16.291675 | |
58 | 7 | -0.27570686E-12 | 0.13707328E-14 | -0.80264236E-13 | 0.78378346E-16 |
59 | 6 | 0.25615968E-07 | 0.28022365E-09 | 0.58936169E-08 | -0.11887149E-12 |
60 | 5 | -0.17446821E-03 | 0.24481169E-05 | -0.89927666E-04 | 0.58344893E-08 |
61 | 4 | 0.27366067 | 0.12133616E-02 | 0.93044102E-01 | -0.30982017E-04 |
62 | 3 | -6.8997845 | 0.38197916E-01 | -2.2301787 | 0.27213971E-01 |
63 | 2 | 39.661773 | 0.13771433 | 14.818013 | -0.31987377 |
64 | 1 | -79.618511 | 0.62899977E-01 | -28.740542 | 1.0588596 |
65 | 0 | 46.824345 | 0.12804488E-02 | 16.301062 | |
66 | 7 | -0.18778705E-08 | -0.48456698E-15 | 0.68415356E-14 | -0.90766841E-16 |
67 | 6 | 0.62832840E-05 | 0.42957215E-08 | 0.31879255E-02 | -0.26742991E-04 |
68 | 5 | -0.45150393E-03 | 0.25448514E-05 | -0.22361406 | 0.19551748E-02 |
69 | 4 | 0.10383635E-01 | 0.11583744E-03 | 4.8277051 | -0.45247288E-01 |
70 | 3 | -0.91177470E-01 | 0.92119394E-03 | -38.011019 | 0.39853883 |
71 | 2 | 0.32374524 | 0.15324382E-02 | 116.46371 | -1.4176686 |
72 | 1 | -0.46727348 | 0.46697369E-03 | -143.89540 | 2.0488441 |
73 | 0 | 0.22781756 | 0.11275910E-04 | 60.838472 | |
74 | 7 | -0.17777358E-08 | -0.41207670E-15 | 0.60771148E-14 | -0.79247013E-16 |
75 | 6 | 0.66205355E-05 | 0.45347915E-08 | 0.31869553E-02 | -0.26734852E-04 |
76 | 5 | -0.47643654E-03 | 0.26865296E-05 | -0.22355891 | 0.19546881E-02 |
77 | 4 | 0.10961386E-01 | 0.12229770E-03 | 4.8267865 | -0.45238458E-01 |
78 | 3 | -0.96263561E-01 | 0.97262436E-03 | -38.005829 | 0.39848146 |
79 | 2 | 0.34182167 | 0.16181264E-02 | 116.45361 | -1.4175335 |
80 | 1 | -0.49337445 | 0.49308431E-03 | -143.88945 | 2.0487464 |
81 | 0 | 0.24054552 | 0.11921404E-04 | 60.838472 | |
82 | 7 | -0.18778705E-08 | -0.48456747E-15 | 0.68415356E-14 | -0.90766840E-16 |
83 | 6 | 0.62832840E-05 | 0.42957215E-08 | 0.31879255E-02 | -0.26742991E-04 |
84 | 5 | -0.45150393E-03 | 0.25448514E-05 | -0.22361406 | 0.19551748E-02 |
85 | 4 | 0.10383635E-01 | 0.11583744E-03 | 4.8277051 | -0.45247288E-01 |
86 | 3 | -0.91177470E-01 | 0.92119394E-03 | -38.011019 | 0.39853883 |
87 | 2 | 0.32374524 | 0.15324382E-02 | 116.46371 | -1.4176686 |
88 | 1 | -0.46727348 | 0.46697369E-03 | -143.89540 | 2.0488441 |
89 | 0 | 0.22781756 | 0.11275910E-04 | 60.838472 | |
90 | 7 | -0.17776120E-08 | -0.41258204E-15 | 0.60425363E-14 | -0.82023253E-16 |
91 | 6 | 0.66209765E-05 | 0.45351028E-08 | 0.31869540E-02 | -0.26734841E-04 |
92 | 5 | -0.47646911E-03 | 0.26867147E-05 | -0.22355884 | 0.19546874E-02 |
93 | 4 | 0.10962140E-01 | 0.12230614E-03 | 4.8267853 | -0.45238446E-01 |
94 | 3 | -0.96270204E-01 | 0.97269154E-03 | -38.005822 | 0.39848139 |
95 | 2 | 0.34184528 | 0.16182383E-02 | 116.45360 | -1.4175333 |
96 | 1 | -0.49340854 | 0.49311848E-03 | -143.88944 | 2.0487463 |
97 | 0 | 0.24056214 | 0.11922214E-04 | 60.838472 | |
98 | 8 | 0.57026216E-10 | -0.29656739E-13 | 0.26072253E-13 | -0.16907584E-15 |
99 | 7 | -0.80728763E-07 | 0.14958947E-11 | -0.10196182E-04 | 0.85534123E-07 |
100 | 6 | 0.59163330E-05 | 0.23390251E-08 | 0.39199948E-02 | -0.33137873E-04 |
101 | 5 | -0.14678961E-03 | 0.29443049E-06 | -0.24001665 | 0.21083805E-02 |
102 | 4 | 0.15257864E-02 | 0.63469284E-05 | 4.9653291 | -0.46676227E-01 |
103 | 3 | -0.74362311E-02 | 0.30151767E-04 | -38.474208 | 0.40407555 |
104 | 2 | 0.17883035E-01 | 0.32406056E-04 | 117.10039 | -1.4265819 |
105 | 1 | -0.20235698E-01 | 0.62001922E-05 | -144.19380 | 2.0537490 |
106 | 0 | 0.84795330E-02 | 0.69040512E-07 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | Conductance (Before Adjusted) {W/m2-K} | Convection Coefficient Adjustment Ratio | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | WINDOW_U_0.38_SHGC_EAST_0.38 | 35 | 1 | VerySmooth | 2.159 | 2.159 | 1.000 | 0.381 | ||
2 | WINDOW_U_0.38_SHGC_SOUTH_0.38 | 36 | 1 | VerySmooth | 2.159 | 2.159 | 1.000 | 0.381 | ||
3 | WINDOW_U_0.38_SHGC_WEST_0.38 | 37 | 1 | VerySmooth | 2.159 | 2.159 | 1.000 | 0.381 | ||
4 | WINDOW_U_0.38_SHGC_NORTH_0.38 | 38 | 1 | VerySmooth | 2.159 | 2.159 | 1.000 | 0.381 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | GLAZING LAYER EAST | SpectralAverage | 3.45900E-002 | 0.29373 | 0.49855 | 0.49855 | 0.41800 | 0.13582 | 0.17513 | 0.00000 | 0.84000 | 0.84000 | 0.11893 | 1.00000 | No | |
2 | GLAZING LAYER SOUTH | SpectralAverage | 3.45900E-002 | 0.29373 | 0.49855 | 0.49855 | 0.41800 | 0.13582 | 0.17513 | 0.00000 | 0.84000 | 0.84000 | 0.11893 | 1.00000 | No | |
3 | GLAZING LAYER WEST | SpectralAverage | 3.45900E-002 | 0.29373 | 0.49855 | 0.49855 | 0.41800 | 0.13582 | 0.17513 | 0.00000 | 0.84000 | 0.84000 | 0.11893 | 1.00000 | No | |
4 | GLAZING LAYER NORTH | SpectralAverage | 3.45900E-002 | 0.29373 | 0.49855 | 0.49855 | 0.41800 | 0.13582 | 0.17513 | 0.00000 | 0.84000 | 0.84000 | 0.11893 | 1.00000 | No |
Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | PolygonClipping | Periodic | 30 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
Enclosure Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Enclosures | |
1 | PERIMETER_TOP_ZN_3 | 1 | 0 |
2 | PERIMETER_TOP_ZN_2 | 1 | 0 |
3 | PERIMETER_TOP_ZN_1 | 1 | 0 |
4 | PERIMETER_TOP_ZN_4 | 1 | 0 |
5 | PERIMETER_BOT_ZN_3 | 3 | 0 |
6 | PERIMETER_BOT_ZN_2 | 2 | 0 |
7 | PERIMETER_BOT_ZN_1 | 3 | 0 |
8 | PERIMETER_BOT_ZN_4 | 2 | 0 |
9 | PERIMETER_MID_ZN_3 | 1 | 0 |
10 | PERIMETER_MID_ZN_2 | 1 | 0 |
11 | PERIMETER_MID_ZN_1 | 1 | 0 |
12 | PERIMETER_MID_ZN_4 | 1 | 0 |
Enclosure Name | Number of Adjacent Enclosures with Windows | Adjacent Enclosure Names - 1st 100 (max) | |
1 | PERIMETER_TOP_ZN_3 | 0 | |
2 | PERIMETER_TOP_ZN_2 | 0 | |
3 | PERIMETER_TOP_ZN_1 | 0 | |
4 | PERIMETER_TOP_ZN_4 | 0 | |
5 | PERIMETER_BOT_ZN_3 | 0 | |
6 | PERIMETER_BOT_ZN_2 | 0 | |
7 | PERIMETER_BOT_ZN_1 | 0 | |
8 | PERIMETER_BOT_ZN_4 | 0 | |
9 | PERIMETER_MID_ZN_3 | 0 | |
10 | PERIMETER_MID_ZN_2 | 0 | |
11 | PERIMETER_MID_ZN_1 | 0 | |
12 | PERIMETER_MID_ZN_4 | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 0.3785 | 29307.1 | 27.185 | 0.8451 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | CORE_BOT_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
2 | CORE_BOT_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
3 | CORE_BOT_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
4 | CORE_BOT_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
5 | CORE_BOT_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
6 | CORE_BOT_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
7 | CORE_BOTTOM_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
8 | PERIMETER_TOP_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
9 | PERIMETER_TOP_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
10 | PERIMETER_TOP_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
11 | PERIMETER_TOP_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
12 | iz-PERIMETER_TOP_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
13 | iz-PERIMETER_TOP_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
14 | iz-PERIMETER_TOP_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
15 | iz-PERIMETER_TOP_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
16 | iz-CORE_TOP_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
17 | BUILDING_ROOF | 0 | 1660.73 | 183.01 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
18 | PERIMETER_MID_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
19 | PERIMETER_MID_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
20 | PERIMETER_MID_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
21 | PERIMETER_MID_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
22 | iz-PERIMETER_MID_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
23 | iz-PERIMETER_MID_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
24 | iz-PERIMETER_MID_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
25 | iz-PERIMETER_MID_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
26 | iz-CORE_MID_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
27 | iz-PERIMETER_TOP_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
28 | iz-PERIMETER_TOP_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
29 | iz-PERIMETER_TOP_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
30 | iz-PERIMETER_TOP_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
31 | iz-CORE_TOP_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
32 | PERIMETER_BOT_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
33 | PERIMETER_BOT_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
34 | PERIMETER_BOT_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
35 | PERIMETER_BOT_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
36 | iz-PERIMETER_BOT_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
37 | iz-PERIMETER_BOT_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
38 | iz-PERIMETER_BOT_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
39 | iz-PERIMETER_BOT_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
40 | iz-CORE_BOT_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
41 | iz-PERIMETER_MID_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
42 | iz-PERIMETER_MID_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
43 | iz-PERIMETER_MID_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
44 | iz-PERIMETER_MID_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
45 | iz-CORE_MID_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
46 | CORE_MID_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
47 | CORE_MID_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
48 | CORE_MID_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
49 | CORE_MID_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
50 | CORE_MID_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
51 | CORE_MID_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
52 | CORE_MID_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
53 | CORE_TOP_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
54 | CORE_TOP_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
55 | CORE_TOP_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
56 | CORE_TOP_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
57 | CORE_TOP_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
58 | CORE_TOP_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
59 | CORE_TOP_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
60 | PERIMETER_TOP_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
61 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
62 | PERIMETER_TOP_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
63 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
64 | iz-CORE_TOP_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
65 | PERIMETER_TOP_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
66 | PERIMETER_TOP_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
67 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
68 | PERIMETER_TOP_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
69 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
70 | PERIMETER_TOP_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
71 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
72 | iz-CORE_TOP_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
73 | PERIMETER_TOP_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
74 | PERIMETER_TOP_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
75 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
76 | PERIMETER_TOP_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
77 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
78 | PERIMETER_TOP_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
79 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
80 | iz-CORE_TOP_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
81 | PERIMETER_TOP_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
82 | PERIMETER_TOP_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
83 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
84 | PERIMETER_TOP_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
85 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
86 | PERIMETER_TOP_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
87 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
88 | iz-CORE_TOP_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
89 | PERIMETER_TOP_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
90 | PERIMETER_TOP_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
91 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
92 | PERIMETER_BOT_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
93 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
94 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
95 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
96 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
97 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
98 | PERIMETER_BOT_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
99 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
100 | iz-CORE_BOT_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
101 | PERIMETER_BOT_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
102 | PERIMETER_BOT_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
103 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
104 | PERIMETER_BOT_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
105 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
106 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
107 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
108 | PERIMETER_BOT_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
109 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
110 | iz-CORE_BOT_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
111 | PERIMETER_BOT_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
112 | PERIMETER_BOT_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
113 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
114 | PERIMETER_BOT_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
115 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
116 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
117 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
118 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
119 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
120 | PERIMETER_BOT_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
121 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
122 | iz-CORE_BOT_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
123 | PERIMETER_BOT_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
124 | PERIMETER_BOT_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
125 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
126 | PERIMETER_BOT_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
127 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
128 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
129 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
130 | PERIMETER_BOT_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
131 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
132 | iz-CORE_BOT_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
133 | PERIMETER_BOT_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
134 | PERIMETER_BOT_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
135 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
136 | PERIMETER_MID_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
137 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
138 | PERIMETER_MID_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
139 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
140 | iz-CORE_MID_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
141 | PERIMETER_MID_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
142 | PERIMETER_MID_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
143 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
144 | PERIMETER_MID_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
145 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
146 | PERIMETER_MID_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
147 | iz-PERIMETER_MID_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
148 | iz-CORE_MID_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
149 | PERIMETER_MID_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
150 | PERIMETER_MID_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
151 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
152 | PERIMETER_MID_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
153 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
154 | PERIMETER_MID_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
155 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
156 | iz-CORE_MID_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
157 | PERIMETER_MID_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
158 | PERIMETER_MID_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
159 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
160 | PERIMETER_MID_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
161 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
162 | PERIMETER_MID_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
163 | iz-PERIMETER_MID_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
164 | iz-CORE_MID_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
165 | PERIMETER_MID_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
166 | PERIMETER_MID_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
167 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | PERIMETER_TOP_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 3.509E-002 | 1.693E-004 | 2.563E-004 | 0.222 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | PERIMETER_TOP_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 2.339E-002 | 1.782E-004 | 2.563E-004 | 0.234 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | PERIMETER_TOP_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 3.509E-002 | 1.693E-004 | 2.563E-004 | 0.222 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | PERIMETER_TOP_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 2.339E-002 | 1.782E-004 | 2.563E-004 | 0.234 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | PERIMETER_BOT_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 3.509E-002 | 1.693E-004 | 2.492E-004 | 0.222 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | PERIMETER_BOT_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 2.339E-002 | 1.782E-004 | 2.509E-004 | 0.234 | 0.000 | 0.000 | 0.224 | 0.000 |
7 | PERIMETER_BOT_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 3.509E-002 | 1.693E-004 | 2.492E-004 | 0.222 | 0.000 | 0.000 | 0.224 | 0.000 |
8 | PERIMETER_BOT_ZN_1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 0.679 | 3.273E-003 | 4.819E-003 | 4.296 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | PERIMETER_BOT_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 2.339E-002 | 1.782E-004 | 2.509E-004 | 0.234 | 0.000 | 0.000 | 0.224 | 0.000 |
10 | PERIMETER_MID_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 3.509E-002 | 1.693E-004 | 2.563E-004 | 0.222 | 0.000 | 0.000 | 0.224 | 0.000 |
11 | PERIMETER_MID_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 2.339E-002 | 1.782E-004 | 2.563E-004 | 0.234 | 0.000 | 0.000 | 0.224 | 0.000 |
12 | PERIMETER_MID_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 3.509E-002 | 1.693E-004 | 2.563E-004 | 0.222 | 0.000 | 0.000 | 0.224 | 0.000 |
13 | PERIMETER_MID_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 2.339E-002 | 1.782E-004 | 2.563E-004 | 0.234 | 0.000 | 0.000 | 0.224 | 0.000 |
14 | FIRSTFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | FIRSTFLOOR_PLENUM | 1660.73 | 0.0 | 5.199E-002 | 3.130E-005 | 2.563E-004 | 9.244E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
15 | MIDFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | MIDFLOOR_PLENUM | 1660.73 | 0.0 | 5.199E-002 | 3.130E-005 | 2.563E-004 | 9.244E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
16 | TOPFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | TOPFLOOR_PLENUM | 1660.73 | 0.0 | 5.199E-002 | 3.130E-005 | 2.790E-005 | 9.244E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | CORE_BOTTOM | Mixing/Well-Stirred |
2 | TOPFLOOR_PLENUM | Mixing/Well-Stirred |
3 | MIDFLOOR_PLENUM | Mixing/Well-Stirred |
4 | FIRSTFLOOR_PLENUM | Mixing/Well-Stirred |
5 | CORE_MID | Mixing/Well-Stirred |
6 | CORE_TOP | Mixing/Well-Stirred |
7 | PERIMETER_TOP_ZN_3 | Mixing/Well-Stirred |
8 | PERIMETER_TOP_ZN_2 | Mixing/Well-Stirred |
9 | PERIMETER_TOP_ZN_1 | Mixing/Well-Stirred |
10 | PERIMETER_TOP_ZN_4 | Mixing/Well-Stirred |
11 | PERIMETER_BOT_ZN_3 | Mixing/Well-Stirred |
12 | PERIMETER_BOT_ZN_2 | Mixing/Well-Stirred |
13 | PERIMETER_BOT_ZN_1 | Mixing/Well-Stirred |
14 | PERIMETER_BOT_ZN_4 | Mixing/Well-Stirred |
15 | PERIMETER_MID_ZN_3 | Mixing/Well-Stirred |
16 | PERIMETER_MID_ZN_2 | Mixing/Well-Stirred |
17 | PERIMETER_MID_ZN_1 | Mixing/Well-Stirred |
18 | PERIMETER_MID_ZN_4 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sky Type | MonthAndDay | Daylighting Control Name | Enclosure Name | Window Name | Reference Point | Daylight Factor | |
1 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 1.2970E-002 |
2 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.3038E-002 |
3 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 1.4580E-002 |
4 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.4639E-002 |
5 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 8.1631E-003 |
6 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 8.2101E-003 |
7 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 4.3739E-003 |
8 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 4.3982E-003 |
9 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 0.1731 |
10 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 0.1005 |
11 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 0.1989 |
12 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 0.1166 |
13 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 0.1144 |
14 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 5.0096E-002 |
15 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 4.8328E-002 |
16 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.8130E-002 |
17 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 1.2972E-002 |
18 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.3052E-002 |
19 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 1.4582E-002 |
20 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.4655E-002 |
21 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 8.1649E-003 |
22 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 8.2191E-003 |
23 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 4.3736E-003 |
24 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 4.3979E-003 |
25 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 8.1195E-002 |
26 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 4.7424E-002 |
27 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 7.8376E-002 |
28 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 4.5002E-002 |
29 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 7.6191E-002 |
30 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 3.8532E-002 |
31 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 5.6742E-002 |
32 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 2.6741E-002 |
33 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 7.1963E-004 |
34 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 7.2245E-004 |
35 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 6.9432E-004 |
36 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 6.9637E-004 |
37 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 6.3390E-004 |
38 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 6.3461E-004 |
39 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 5.1047E-004 |
40 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 5.1131E-004 |
41 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.8708E-003 |
42 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 4.9312E-003 |
43 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.0641E-003 |
44 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 4.1134E-003 |
45 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 3.4976E-003 |
46 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 3.5341E-003 |
47 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.3736E-003 |
48 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 4.3979E-003 |
49 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.7481E-002 |
50 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.7207E-002 |
51 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 3.6682E-002 |
52 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.0804E-002 |
53 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 3.3427E-002 |
54 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.4048E-002 |
55 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.8328E-002 |
56 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.8130E-002 |
57 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.8705E-003 |
58 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 4.9320E-003 |
59 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.0633E-003 |
60 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 4.1120E-003 |
61 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 3.4959E-003 |
62 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 3.5277E-003 |
63 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.3739E-003 |
64 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 4.3982E-003 |
65 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 6.8515E-002 |
66 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 4.1036E-002 |
67 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 6.2133E-002 |
68 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 3.6779E-002 |
69 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 6.6907E-002 |
70 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 3.4079E-002 |
71 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 5.6742E-002 |
72 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 2.6742E-002 |
73 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 6.3941E-004 |
74 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 6.4819E-004 |
75 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 5.9115E-004 |
76 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 6.0111E-004 |
77 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 5.7742E-004 |
78 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 5.8054E-004 |
79 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 5.1049E-004 |
80 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 5.1133E-004 |
81 | Clear Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 0.1738 |
82 | Clear Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 0.1204 |
83 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 0.1965 |
84 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 0.1389 |
85 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 0.1232 |
86 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 6.3309E-002 |
87 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 5.5097E-002 |
88 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 2.5717E-002 |
89 | Clear Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 7.8453E-002 |
90 | Clear Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 4.5852E-002 |
91 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 7.5838E-002 |
92 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 4.3544E-002 |
93 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 7.4357E-002 |
94 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 3.7441E-002 |
95 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 5.5687E-002 |
96 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 2.6108E-002 |
97 | Clear Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 5.3871E-002 |
98 | Clear Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 3.5233E-002 |
99 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 4.2350E-002 |
100 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 2.7691E-002 |
101 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 3.9085E-002 |
102 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 2.0304E-002 |
103 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 5.5097E-002 |
104 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 2.5717E-002 |
105 | Clear Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 6.6203E-002 |
106 | Clear Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 3.9755E-002 |
107 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 6.0152E-002 |
108 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 3.5699E-002 |
109 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 6.5356E-002 |
110 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 3.3179E-002 |
111 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 5.5688E-002 |
112 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 2.6108E-002 |
113 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 0.1738 |
114 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 0.1204 |
115 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 0.1966 |
116 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 0.1389 |
117 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 0.1232 |
118 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 6.3302E-002 |
119 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 5.5092E-002 |
120 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 2.5714E-002 |
121 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 7.8453E-002 |
122 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 4.5849E-002 |
123 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 7.5837E-002 |
124 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 4.3540E-002 |
125 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 7.4352E-002 |
126 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 3.7437E-002 |
127 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 5.5682E-002 |
128 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 2.6105E-002 |
129 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 5.3873E-002 |
130 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 3.5231E-002 |
131 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 4.2351E-002 |
132 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 2.7689E-002 |
133 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 3.9083E-002 |
134 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 2.0302E-002 |
135 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 5.5092E-002 |
136 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 2.5714E-002 |
137 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 6.6203E-002 |
138 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 3.9753E-002 |
139 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 6.0151E-002 |
140 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 3.5697E-002 |
141 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 6.5352E-002 |
142 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 3.3175E-002 |
143 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 5.5683E-002 |
144 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 2.6105E-002 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | CORE_BOTTOM | Cooling | 37193.53802 | 37193.53802 | 2.70819 | 2.70819 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 19.66600 | 8.39663E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
2 | CORE_BOTTOM | Heating | 5207.86767 | 5207.86767 | 0.22172 | 0.42469 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
3 | CORE_MID | Cooling | 29932.85781 | 29932.85781 | 2.17751 | 2.17751 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 19.66600 | 8.39663E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
4 | CORE_MID | Heating | 11632.72292 | 11632.72292 | 0.49611 | 0.49611 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
5 | CORE_TOP | Cooling | 29861.98615 | 29861.98615 | 2.19295 | 2.19295 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:10:00 | 26.30900 | 8.40693E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
6 | CORE_TOP | Heating | 21227.36198 | 21227.36198 | 0.91080 | 0.91080 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
7 | PERIMETER_TOP_ZN_3 | Cooling | 8013.77273 | 8013.77273 | 0.58849 | 0.58849 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:10:00 | 26.30900 | 8.40693E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
8 | PERIMETER_TOP_ZN_3 | Heating | 9267.27487 | 9267.27487 | 0.39905 | 0.39905 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
9 | PERIMETER_TOP_ZN_2 | Cooling | 10714.55042 | 10714.55042 | 0.78682 | 0.78682 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:10:00 | 21.65283 | 8.39969E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
10 | PERIMETER_TOP_ZN_2 | Heating | 6079.03674 | 6079.03674 | 0.26179 | 0.26179 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
11 | PERIMETER_TOP_ZN_1 | Cooling | 16051.01706 | 16051.01706 | 1.17870 | 1.17870 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | 26.17250 | 8.40672E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
12 | PERIMETER_TOP_ZN_1 | Heating | 9294.42657 | 9294.42657 | 0.40022 | 0.40022 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
13 | PERIMETER_TOP_ZN_4 | Cooling | 11837.17064 | 11837.17064 | 0.86926 | 0.86926 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 17:10:00 | 24.97433 | 8.40484E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
14 | PERIMETER_TOP_ZN_4 | Heating | 6055.76894 | 6055.76894 | 0.26079 | 0.26079 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
15 | PERIMETER_BOT_ZN_3 | Cooling | 6377.68190 | 6377.68190 | 0.46835 | 0.46835 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:50:00 | 26.40000 | 8.40708E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
16 | PERIMETER_BOT_ZN_3 | Heating | 7201.82617 | 7201.82617 | 0.30985 | 0.30985 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
17 | PERIMETER_BOT_ZN_2 | Cooling | 8776.08130 | 8776.08130 | 0.64447 | 0.64447 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:20:00 | 21.91067 | 8.40008E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
18 | PERIMETER_BOT_ZN_2 | Heating | 4799.88518 | 4799.88518 | 0.20655 | 0.20655 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
19 | PERIMETER_BOT_ZN_1 | Cooling | 13123.79755 | 13123.79755 | 0.96374 | 0.96374 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 26.32417 | 8.40696E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
20 | PERIMETER_BOT_ZN_1 | Heating | 7238.09333 | 7238.09333 | 0.31141 | 0.31141 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
21 | PERIMETER_BOT_ZN_4 | Cooling | 9853.42101 | 9853.42101 | 0.72358 | 0.72358 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 18:00:00 | 24.21600 | 8.40365E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
22 | PERIMETER_BOT_ZN_4 | Heating | 4776.22806 | 4776.22806 | 0.20553 | 0.20553 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
23 | PERIMETER_MID_ZN_3 | Cooling | 7159.85867 | 7159.85867 | 0.52579 | 0.52579 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:50:00 | 26.40000 | 8.40708E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
24 | PERIMETER_MID_ZN_3 | Heating | 7073.84544 | 7073.84544 | 0.30429 | 0.30429 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
25 | PERIMETER_MID_ZN_2 | Cooling | 10790.26941 | 10790.26941 | 0.79238 | 0.79238 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:50:00 | 21.10683 | 8.39884E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
26 | PERIMETER_MID_ZN_2 | Heating | 4690.68809 | 4690.68809 | 0.20181 | 0.20181 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
27 | PERIMETER_MID_ZN_1 | Cooling | 15052.07935 | 15052.07935 | 1.10535 | 1.10535 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 | 26.09667 | 8.40660E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
28 | PERIMETER_MID_ZN_1 | Heating | 7099.21484 | 7099.21484 | 0.30538 | 0.30538 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
29 | PERIMETER_MID_ZN_4 | Cooling | 11114.98194 | 11114.98194 | 0.81622 | 0.81622 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 17:10:00 | 24.97433 | 8.40484E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
30 | PERIMETER_MID_ZN_4 | Heating | 4667.23815 | 4667.23815 | 0.20080 | 0.20080 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PACU_VAV_BOT | Cooling | Sensible | 67599.42 | 4.78672 | 4.78672 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 00:00:00 |
2 | PACU_VAV_BOT | Heating | Sensible | 24444.56 | 1.45803 | 1.45803 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 22:00:00 |
3 | PACU_VAV_MID | Cooling | Sensible | 63407.82 | 4.47412 | 4.47412 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 00:00:00 |
4 | PACU_VAV_MID | Heating | Sensible | 24465.34 | 1.50840 | 1.50840 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 14:30:00 |
5 | PACU_VAV_TOP | Cooling | Sensible | 70279.31 | 4.99125 | 4.99125 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 00:00:00 |
6 | PACU_VAV_TOP | Heating | Sensible | 24297.44 | 2.23265 | 2.23265 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 06:30:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.70819 |
2 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.27674 |
3 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.28500 |
4 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.77183 |
5 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.73796 |
6 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
7 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.37676E-003 |
8 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.12826E-004 |
9 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.77183 |
10 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
11 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
12 | Coil:Heating:Water | CORE_BOTTOM VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 12896.72803 |
13 | Coil:Heating:Water | CORE_BOTTOM VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.12826E-004 |
14 | Coil:Heating:Water | CORE_BOTTOM VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 278.63151 |
15 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.17751 |
16 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.34418 |
17 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.34800 |
18 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.75777 |
19 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.91781 |
20 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
21 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.10698E-003 |
22 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.67808E-004 |
23 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.75777 |
24 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
25 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
26 | Coil:Heating:Water | CORE_MID VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 19181.53445 |
27 | Coil:Heating:Water | CORE_MID VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.67808E-004 |
28 | Coil:Heating:Water | CORE_MID VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 457.09784 |
29 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.19295 |
30 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.34176 |
31 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.35600 |
32 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.78069 |
33 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.91135 |
34 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
35 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.11483E-003 |
36 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.65082E-004 |
37 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.91080 |
38 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
39 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
40 | Coil:Heating:Water | CORE_TOP VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 30300.53726 |
41 | Coil:Heating:Water | CORE_TOP VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.65082E-004 |
42 | Coil:Heating:Water | CORE_TOP VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 800.19069 |
43 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.58849 |
44 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.26847 |
45 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.28000 |
46 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16478 |
47 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.71591 |
48 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
49 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.41916E-003 |
50 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.15845E-004 |
51 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.39905 |
52 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
53 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
54 | Coil:Heating:Water | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 13241.80446 |
55 | Coil:Heating:Water | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.15845E-004 |
56 | Coil:Heating:Water | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 349.28692 |
57 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.78682 |
58 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.12712 |
59 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
60 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.15736 |
61 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.33899 |
62 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
63 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.99712E-003 |
64 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 7.59934E-005 |
65 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.26179 |
66 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
67 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
68 | Coil:Heating:Water | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 8686.51723 |
69 | Coil:Heating:Water | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.59934E-005 |
70 | Coil:Heating:Water | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 229.12082 |
71 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.17870 |
72 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.13404 |
73 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
74 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.23574 |
75 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.35744 |
76 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
77 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.84246E-003 |
78 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.16185E-004 |
79 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.40022 |
80 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
81 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
82 | Coil:Heating:Water | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 13280.64727 |
83 | Coil:Heating:Water | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.16185E-004 |
84 | Coil:Heating:Water | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 350.31038 |
85 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.86926 |
86 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.11506 |
87 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
88 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.17385 |
89 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.30682 |
90 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
91 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.31136E-003 |
92 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 7.57022E-005 |
93 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.26079 |
94 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
95 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
96 | Coil:Heating:Water | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 8653.23208 |
97 | Coil:Heating:Water | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.57022E-005 |
98 | Coil:Heating:Water | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 228.24377 |
99 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.46835 |
100 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.33734 |
101 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.34800 |
102 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16299 |
103 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.89957 |
104 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
105 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.12943E-003 |
106 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.00024E-005 |
107 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.30985 |
108 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
109 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
110 | Coil:Heating:Water | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 10287.82765 |
111 | Coil:Heating:Water | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.00024E-005 |
112 | Coil:Heating:Water | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 271.44020 |
113 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.64447 |
114 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.15520 |
115 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
116 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.12889 |
117 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.41387 |
118 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
119 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.45489E-003 |
120 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 5.99886E-005 |
121 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.20655 |
122 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
123 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
124 | Coil:Heating:Water | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 6857.06926 |
125 | Coil:Heating:Water | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 5.99886E-005 |
126 | Coil:Heating:Water | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 180.91009 |
127 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.96374 |
128 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.16394 |
129 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
130 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.19275 |
131 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.43716 |
132 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
133 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.32409E-003 |
134 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.04561E-005 |
135 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.31141 |
136 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
137 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
138 | Coil:Heating:Water | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 10339.69272 |
139 | Coil:Heating:Water | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.04561E-005 |
140 | Coil:Heating:Water | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 272.80730 |
141 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.72358 |
142 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.13822 |
143 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
144 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.14472 |
145 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.36859 |
146 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
147 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.75643E-003 |
148 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 5.96926E-005 |
149 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.20553 |
150 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
151 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
152 | Coil:Heating:Water | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 6823.22665 |
153 | Coil:Heating:Water | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 5.96926E-005 |
154 | Coil:Heating:Water | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 180.01835 |
155 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.52579 |
156 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.30049 |
157 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.30400 |
158 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.15984 |
159 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.80130 |
160 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
161 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.26795E-003 |
162 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 8.83959E-005 |
163 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.30429 |
164 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
165 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
166 | Coil:Heating:Water | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 10104.19185 |
167 | Coil:Heating:Water | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.83959E-005 |
168 | Coil:Heating:Water | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 266.60674 |
169 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.79238 |
170 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.12623 |
171 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
172 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.15848 |
173 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.33661 |
174 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
175 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.01831E-003 |
176 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 5.86192E-005 |
177 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.20181 |
178 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
179 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
180 | Coil:Heating:Water | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 6700.53184 |
181 | Coil:Heating:Water | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 5.86192E-005 |
182 | Coil:Heating:Water | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 176.78806 |
183 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.10535 |
184 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.14293 |
185 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
186 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.22107 |
187 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.38116 |
188 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
189 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.66556E-003 |
190 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 8.87133E-005 |
191 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.30538 |
192 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
193 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
194 | Coil:Heating:Water | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 10140.47323 |
195 | Coil:Heating:Water | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.87133E-005 |
196 | Coil:Heating:Water | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 267.56310 |
197 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.81622 |
198 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.12253 |
199 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
200 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16324 |
201 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.32676 |
202 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
203 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.10934E-003 |
204 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 5.83257E-005 |
205 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.20080 |
206 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.80000 |
207 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
208 | Coil:Heating:Water | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 6666.98479 |
209 | Coil:Heating:Water | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 5.83257E-005 |
210 | Coil:Heating:Water | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 175.90409 |
211 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.75417 |
212 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.40118 |
213 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Maximum Flow Rates [m3/s] | 5.50833 |
214 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Heating Design Air Flow Rate [m3/s] | 1.45803 |
215 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Cooling Design Air Flow Rate [m3/s] | 4.78672 |
216 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Main Design Air Flow Rate [m3/s] | 4.78672 |
217 | AirLoopHVAC | PACU_VAV_BOT | User Heating Air Flow Ratio [] | 0.30000 |
218 | AirLoopHVAC | PACU_VAV_BOT | Calculated Heating Air Flow Ratio [] | 0.30460 |
219 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.70862 |
220 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.46040 |
221 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Maximum Flow Rates [m3/s] | 5.41725 |
222 | AirLoopHVAC | PACU_VAV_MID | Adjusted Heating Design Air Flow Rate [m3/s] | 1.50840 |
223 | AirLoopHVAC | PACU_VAV_MID | Adjusted Cooling Design Air Flow Rate [m3/s] | 4.47412 |
224 | AirLoopHVAC | PACU_VAV_MID | Adjusted Main Design Air Flow Rate [m3/s] | 4.47412 |
225 | AirLoopHVAC | PACU_VAV_MID | User Heating Air Flow Ratio [] | 0.30000 |
226 | AirLoopHVAC | PACU_VAV_MID | Calculated Heating Air Flow Ratio [] | 0.33714 |
227 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.80811 |
228 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.51242 |
229 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Maximum Flow Rates [m3/s] | 5.61622 |
230 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Heating Design Air Flow Rate [m3/s] | 2.23265 |
231 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Cooling Design Air Flow Rate [m3/s] | 4.99125 |
232 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Main Design Air Flow Rate [m3/s] | 4.99125 |
233 | AirLoopHVAC | PACU_VAV_TOP | User Heating Air Flow Ratio [] | 0.30000 |
234 | AirLoopHVAC | PACU_VAV_TOP | Calculated Heating Air Flow Ratio [] | 0.44731 |
235 | AirLoopHVAC | PACU_VAV_BOT | Design Supply Air Flow Rate [m3/s] | 4.78672 |
236 | AirLoopHVAC | PACU_VAV_MID | Design Supply Air Flow Rate [m3/s] | 4.47412 |
237 | AirLoopHVAC | PACU_VAV_TOP | Design Supply Air Flow Rate [m3/s] | 4.99125 |
238 | Controller:OutdoorAir | PACU_VAV_BOT_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 4.78672 |
239 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 4.78672 |
240 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 79237.19703 |
241 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.80066 |
242 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 1.59541 |
243 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 26409.75777 |
244 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.80066 |
245 | Coil:Heating:Water | PACU_VAV_BOT HEATING COIL | Design Size Rated Capacity [W] | 22102.56569 |
246 | Coil:Heating:Water | PACU_VAV_BOT HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.93363E-004 |
247 | Coil:Heating:Water | PACU_VAV_BOT HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 370.77701 |
248 | Fan:VariableVolume | PACU_VAV_BOT FAN | Design Size Maximum Flow Rate [m3/s] | 4.78672 |
249 | Controller:WaterCoil | PACU_VAV_BOT_HEATC_CONTROLLER | Maximum Actuated Flow [m3/s] | 1.93363E-004 |
250 | Controller:OutdoorAir | PACU_VAV_MID_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 4.47412 |
251 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 4.47412 |
252 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 74062.63969 |
253 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.80066 |
254 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 1.49123 |
255 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 24685.07781 |
256 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.80066 |
257 | Coil:Heating:Water | PACU_VAV_MID HEATING COIL | Design Size Rated Capacity [W] | 23023.16105 |
258 | Coil:Heating:Water | PACU_VAV_MID HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.01417E-004 |
259 | Coil:Heating:Water | PACU_VAV_MID HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 382.82495 |
260 | Fan:VariableVolume | PACU_VAV_MID FAN | Design Size Maximum Flow Rate [m3/s] | 4.47412 |
261 | Controller:WaterCoil | PACU_VAV_MID_HEATC_CONTROLLER | Maximum Actuated Flow [m3/s] | 2.01417E-004 |
262 | Controller:OutdoorAir | PACU_VAV_TOP_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 4.99125 |
263 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 4.99125 |
264 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 82622.85341 |
265 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.80066 |
266 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 1.66358 |
267 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 27538.19704 |
268 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.80066 |
269 | Coil:Heating:Water | PACU_VAV_TOP HEATING COIL | Design Size Rated Capacity [W] | 22418.10283 |
270 | Coil:Heating:Water | PACU_VAV_TOP HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.96123E-004 |
271 | Coil:Heating:Water | PACU_VAV_TOP HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 376.87097 |
272 | Fan:VariableVolume | PACU_VAV_TOP FAN | Design Size Maximum Flow Rate [m3/s] | 4.99125 |
273 | Controller:WaterCoil | PACU_VAV_TOP_HEATC_CONTROLLER | Maximum Actuated Flow [m3/s] | 1.96123E-004 |
274 | PlantLoop | HEATSYS1 | Maximum Loop Flow Rate [m3/s] | 2.11454E-003 |
275 | PlantLoop | HEATSYS1 | Plant Loop Volume [m3] | 0.25374 |
276 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Flow Rate [m3/s] | 2.11454E-003 |
277 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Power Consumption [W] | 636.80637 |
278 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Minimum Flow Rate [m3/s] | 0.00000 |
279 | Boiler:HotWater | HEATSYS1 BOILER | Design Size Nominal Capacity [W] | 241704.82836 |
280 | Boiler:HotWater | HEATSYS1 BOILER | User-Specified Nominal Capacity [W] | 241704.83000 |
281 | Boiler:HotWater | HEATSYS1 BOILER | Design Size Design Water Flow Rate [m3/s] | 2.11454E-003 |
282 | PlantLoop | SWHSYS1 | Maximum Loop Flow Rate [m3/s] | 5.36267E-005 |
283 | PlantLoop | SWHSYS1 | Plant Loop Volume [m3] | 6.43520E-003 |
284 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Flow Rate [m3/s] | 5.36267E-005 |
285 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Power Consumption [W] | 6.85023 |
286 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | Use Side Design Flow Rate [m3/s] | 5.36267E-005 |
Component Type | Name | Nominal Total Capacity {W} | |
1 | Coil:Heating:Water | CORE_BOTTOM VAV BOX REHEAT COIL | 12223.91 |
2 | Coil:Heating:Water | CORE_MID VAV BOX REHEAT COIL | 18171.74 |
3 | Coil:Heating:Water | CORE_TOP VAV BOX REHEAT COIL | 28715.41 |
4 | Coil:Heating:Water | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | 12546.35 |
5 | Coil:Heating:Water | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | 8230.24 |
6 | Coil:Heating:Water | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | 12583.14 |
7 | Coil:Heating:Water | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | 8198.71 |
8 | Coil:Heating:Water | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | 9747.99 |
9 | Coil:Heating:Water | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | 6497.19 |
10 | Coil:Heating:Water | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | 9797.13 |
11 | Coil:Heating:Water | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | 6465.13 |
12 | Coil:Heating:Water | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | 9574.07 |
13 | Coil:Heating:Water | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | 6348.92 |
14 | Coil:Heating:Water | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | 9608.44 |
15 | Coil:Heating:Water | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | 6317.14 |
16 | Coil:Heating:Water | PACU_VAV_BOT HEATING COIL | 17681.29 |
17 | Coil:Heating:Water | PACU_VAV_MID HEATING COIL | 18094.40 |
18 | Coil:Heating:Water | PACU_VAV_TOP HEATING COIL | 18010.21 |
DX Coil Type | DX Coil Name | Fan Type | Fan Name | Standard Net Cooling Capacity {W} | Standard Net Cooling Capacity {Btu/h} | IEER {Btu/W-h} | COP 100% Capacity {W/W} | COP 75% Capacity {W/W} | COP 50% Capacity {W/W} | COP 25% Capacity {W/W} | EER 100% Capacity {Btu/W-h} | EER 75% Capacity {Btu/W-h} | EER 50% Capacity {Btu/W-h} | EER 25% Capacity {Btu/W-h} | Supply Air Flow 100% {kg/s} | Supply Air Flow 75% {kg/s} | Supply Air Flow 50% {kg/s} | Supply Air Flow 25% {kg/s} | |
1 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | N/A | N/A | 77873.72 | 265716.17 | 11.56 | 3.01 | 3.31 | 3.48 | 3.67 | 10.26 | 11.29 | 11.87 | 12.54 | 5.4775 | 4.3324 | 2.9040 | 1.2096 |
2 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | N/A | N/A | 72788.21 | 248363.67 | 11.56 | 3.01 | 3.31 | 3.48 | 3.67 | 10.26 | 11.29 | 11.87 | 12.54 | 5.1198 | 4.0495 | 2.7143 | 1.1306 |
3 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | N/A | N/A | 81201.12 | 277069.72 | 11.56 | 3.01 | 3.31 | 3.48 | 3.67 | 10.26 | 11.29 | 11.87 | 12.54 | 5.7116 | 4.5175 | 3.0280 | 1.2612 |
Zone Name | # Surfaces | |
1 | CORE_BOTTOM | 7 |
2 | TOPFLOOR_PLENUM | 10 |
3 | MIDFLOOR_PLENUM | 14 |
4 | FIRSTFLOOR_PLENUM | 14 |
5 | CORE_MID | 7 |
6 | CORE_TOP | 7 |
7 | PERIMETER_TOP_ZN_3 | 8 |
8 | PERIMETER_TOP_ZN_2 | 8 |
9 | PERIMETER_TOP_ZN_1 | 8 |
10 | PERIMETER_TOP_ZN_4 | 8 |
11 | PERIMETER_BOT_ZN_3 | 12 |
12 | PERIMETER_BOT_ZN_2 | 10 |
13 | PERIMETER_BOT_ZN_1 | 12 |
14 | PERIMETER_BOT_ZN_4 | 10 |
15 | PERIMETER_MID_ZN_3 | 8 |
16 | PERIMETER_MID_ZN_2 | 8 |
17 | PERIMETER_MID_ZN_1 | 8 |
18 | PERIMETER_MID_ZN_4 | 8 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | CORE_BOT_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | CORE_BOT_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | CORE_BOT_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | CORE_BOT_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
5 | CORE_BOT_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | CORE_BOT_ZN_5_FLOOR_FFACTOR | 5.650E-003 | 5.642E-003 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_BOT_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
6 | CORE_BOT_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_BOT_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
7 | CORE_BOTTOM_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_BOTTOM_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
8 | PERIMETER_TOP_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.032 | 0.894 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
9 | PERIMETER_TOP_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.032 | 0.894 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | PERIMETER_TOP_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.032 | 0.894 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
11 | PERIMETER_TOP_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.032 | 0.894 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | iz-PERIMETER_TOP_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 225.00 | 180.00 | 6.47 | 40.76 | 0.00 | PERIMETER_TOP_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
13 | iz-PERIMETER_TOP_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 135.00 | 180.00 | 6.47 | 24.13 | 0.00 | PERIMETER_TOP_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
14 | iz-PERIMETER_TOP_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 45.00 | 180.00 | 6.47 | 40.76 | 0.00 | PERIMETER_TOP_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
15 | iz-PERIMETER_TOP_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 315.00 | 180.00 | 6.47 | 24.13 | 0.00 | PERIMETER_TOP_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
16 | iz-CORE_TOP_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 180.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_TOP_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
17 | BUILDING_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 1660.73 | 1660.73 | 1660.73 | 0.00 | 0.00 | 49.91 | 33.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
18 | PERIMETER_MID_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.789 | 0.705 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | PERIMETER_MID_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.789 | 0.705 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | PERIMETER_MID_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.789 | 0.705 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | PERIMETER_MID_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.789 | 0.705 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
22 | iz-PERIMETER_MID_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
23 | iz-PERIMETER_MID_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
24 | iz-PERIMETER_MID_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
25 | iz-PERIMETER_MID_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
26 | iz-CORE_MID_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_MID_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
27 | iz-PERIMETER_TOP_ZN_1_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_TOP_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
28 | iz-PERIMETER_TOP_ZN_2_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_TOP_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
29 | iz-PERIMETER_TOP_ZN_3_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_TOP_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
30 | iz-PERIMETER_TOP_ZN_4_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_TOP_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
31 | iz-CORE_TOP_ZN_5_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | CORE_TOP_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
32 | PERIMETER_BOT_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.802 | 0.716 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | PERIMETER_BOT_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.802 | 0.716 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
34 | PERIMETER_BOT_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.802 | 0.716 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | PERIMETER_BOT_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.802 | 0.716 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
36 | iz-PERIMETER_BOT_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_BOT_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
37 | iz-PERIMETER_BOT_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_BOT_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
38 | iz-PERIMETER_BOT_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_BOT_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
39 | iz-PERIMETER_BOT_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_BOT_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
40 | iz-CORE_BOT_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_BOT_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
41 | iz-PERIMETER_MID_ZN_1_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
42 | iz-PERIMETER_MID_ZN_2_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
43 | iz-PERIMETER_MID_ZN_3_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
44 | iz-PERIMETER_MID_ZN_4_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
45 | iz-CORE_MID_ZN_5_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | CORE_MID_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
46 | CORE_MID_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
47 | CORE_MID_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
48 | CORE_MID_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
49 | CORE_MID_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | CORE_MID_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | iz-CORE_MID_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
51 | CORE_MID_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_MID_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
52 | CORE_MID_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_MID_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
53 | CORE_TOP_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | CORE_TOP_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | CORE_TOP_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
56 | CORE_TOP_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | CORE_TOP_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | iz-CORE_TOP_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
58 | CORE_TOP_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 0.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_TOP_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
59 | CORE_TOP_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_TOP_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
60 | PERIMETER_TOP_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.032 | 0.894 | 71.65 | 136.92 | 71.65 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | Window | PERIMETER_TOP_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_NORTH_0.38 | N/A | 2.159 | No | 65.26 | 65.26 | 65.26 | 0.00 | 90.00 | 49.91 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
62 | PERIMETER_TOP_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
64 | iz-CORE_TOP_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | PERIMETER_TOP_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
66 | PERIMETER_TOP_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 225.00 | 0.00 | 6.47 | 49.91 | 0.00 | iz-PERIMETER_TOP_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
67 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
68 | PERIMETER_TOP_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.032 | 0.894 | 47.77 | 91.28 | 47.77 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | Window | PERIMETER_TOP_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_EAST_0.38 | N/A | 2.159 | No | 43.51 | 43.51 | 43.51 | 90.00 | 90.00 | 33.27 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | PERIMETER_TOP_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
71 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
72 | iz-CORE_TOP_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
73 | PERIMETER_TOP_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
74 | PERIMETER_TOP_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 315.00 | 0.00 | 6.47 | 33.27 | 0.00 | iz-PERIMETER_TOP_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
75 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
76 | PERIMETER_TOP_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.032 | 0.894 | 71.65 | 136.92 | 71.65 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
77 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | Window | PERIMETER_TOP_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_SOUTH_0.38 | N/A | 2.159 | No | 65.26 | 65.26 | 65.26 | 180.00 | 90.00 | 49.91 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
78 | PERIMETER_TOP_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
79 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | iz-CORE_TOP_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | PERIMETER_TOP_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
82 | PERIMETER_TOP_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 45.00 | 0.00 | 6.47 | 49.91 | 0.00 | iz-PERIMETER_TOP_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
83 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
84 | PERIMETER_TOP_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.032 | 0.894 | 47.77 | 91.28 | 47.77 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
85 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | Window | PERIMETER_TOP_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_WEST_0.38 | N/A | 2.159 | No | 43.51 | 43.51 | 43.51 | 270.00 | 90.00 | 33.27 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
86 | PERIMETER_TOP_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
88 | iz-CORE_TOP_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
89 | PERIMETER_TOP_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
90 | PERIMETER_TOP_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 135.00 | 0.00 | 6.47 | 33.27 | 0.00 | iz-PERIMETER_TOP_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
91 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
92 | PERIMETER_BOT_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.802 | 0.716 | 67.75 | 136.92 | 67.75 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
93 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_NORTH_0.38 | N/A | 2.159 | No | 21.75 | 21.75 | 21.75 | 0.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
94 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_NORTH_0.38 | N/A | 2.159 | No | 21.75 | 21.75 | 21.75 | 0.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
95 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_NORTH_0.38 | N/A | 2.159 | No | 21.75 | 21.75 | 21.75 | 0.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
96 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | Door | PERIMETER_BOT_ZN_3_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.065 | 3.065 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
97 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | Door | PERIMETER_BOT_ZN_3_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.065 | 3.065 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
98 | PERIMETER_BOT_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
99 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
100 | iz-CORE_BOT_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
101 | PERIMETER_BOT_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 0.224 | 0.213 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
102 | PERIMETER_BOT_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
103 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
104 | PERIMETER_BOT_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.802 | 0.716 | 45.82 | 91.28 | 45.82 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | Window | PERIMETER_BOT_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_EAST_0.38 | N/A | 2.159 | No | 41.85 | 41.85 | 41.85 | 90.00 | 90.00 | 30.84 | 1.36 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
106 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | Window | PERIMETER_BOT_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_EAST_0.38 | N/A | 2.159 | No | 1.65 | 1.65 | 1.65 | 90.00 | 90.00 | 1.22 | 1.36 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
107 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | Door | PERIMETER_BOT_ZN_2_WALL_EAST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.065 | 3.065 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
108 | PERIMETER_BOT_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
110 | iz-CORE_BOT_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
111 | PERIMETER_BOT_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 0.237 | 0.224 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
112 | PERIMETER_BOT_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
113 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
114 | PERIMETER_BOT_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.802 | 0.716 | 67.75 | 136.92 | 67.75 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
115 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_SOUTH_0.38 | N/A | 2.159 | No | 21.75 | 21.75 | 21.75 | 180.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
116 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_SOUTH_0.38 | N/A | 2.159 | No | 21.75 | 21.75 | 21.75 | 180.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
117 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_SOUTH_0.38 | N/A | 2.159 | No | 21.75 | 21.75 | 21.75 | 180.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
118 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | Door | PERIMETER_BOT_ZN_1_WALL_SOUTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.065 | 3.065 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
119 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | Door | PERIMETER_BOT_ZN_1_WALL_SOUTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.065 | 3.065 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
120 | PERIMETER_BOT_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
121 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
122 | iz-CORE_BOT_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
123 | PERIMETER_BOT_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 0.224 | 0.213 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
124 | PERIMETER_BOT_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
125 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
126 | PERIMETER_BOT_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.802 | 0.716 | 45.82 | 91.28 | 45.82 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
127 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | Window | PERIMETER_BOT_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_WEST_0.38 | N/A | 2.159 | No | 41.85 | 41.85 | 41.85 | 270.00 | 90.00 | 30.84 | 1.36 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
128 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | Window | PERIMETER_BOT_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_WEST_0.38 | N/A | 2.159 | No | 1.65 | 1.65 | 1.65 | 270.00 | 90.00 | 1.22 | 1.36 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
129 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | Door | PERIMETER_BOT_ZN_4_WALL_WEST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.065 | 3.065 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
130 | PERIMETER_BOT_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
131 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
132 | iz-CORE_BOT_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
133 | PERIMETER_BOT_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 0.237 | 0.224 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
134 | PERIMETER_BOT_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
135 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
136 | PERIMETER_MID_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.789 | 0.705 | 71.65 | 136.92 | 71.65 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
137 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | Window | PERIMETER_MID_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_NORTH_0.38 | N/A | 2.159 | No | 65.26 | 65.26 | 65.26 | 0.00 | 90.00 | 49.91 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
138 | PERIMETER_MID_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
139 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
140 | iz-CORE_MID_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
141 | PERIMETER_MID_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
142 | PERIMETER_MID_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
143 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
144 | PERIMETER_MID_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.789 | 0.705 | 47.77 | 91.28 | 47.77 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
145 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | Window | PERIMETER_MID_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_EAST_0.38 | N/A | 2.159 | No | 43.51 | 43.51 | 43.51 | 90.00 | 90.00 | 33.27 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
146 | PERIMETER_MID_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
147 | iz-PERIMETER_MID_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
148 | iz-CORE_MID_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
149 | PERIMETER_MID_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
150 | PERIMETER_MID_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
151 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
152 | PERIMETER_MID_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.789 | 0.705 | 71.65 | 136.92 | 71.65 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
153 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | Window | PERIMETER_MID_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_SOUTH_0.38 | N/A | 2.159 | No | 65.26 | 65.26 | 65.26 | 180.00 | 90.00 | 49.91 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
154 | PERIMETER_MID_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
155 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
156 | iz-CORE_MID_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
157 | PERIMETER_MID_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
158 | PERIMETER_MID_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
159 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
160 | PERIMETER_MID_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.789 | 0.705 | 47.77 | 91.28 | 47.77 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
161 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | Window | PERIMETER_MID_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.38_SHGC_WEST_0.38 | N/A | 2.159 | No | 43.51 | 43.51 | 43.51 | 270.00 | 90.00 | 33.27 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
162 | PERIMETER_MID_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
163 | iz-PERIMETER_MID_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
164 | iz-CORE_MID_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
165 | PERIMETER_MID_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
166 | PERIMETER_MID_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
167 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1Environment:Special Days |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | CORE_BOTTOM | RunPeriod: RUNPERIOD 1 | 6.1304091837E-003 | 6.3074041655E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
2 | TOPFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 0.1267107201 | 6.9498781510E-002 | Pass | Pass | 0.1612465046 | 0.3644305156 | Pass | Pass |
3 | MIDFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 1.0066130831E-002 | 7.9830004296E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
4 | FIRSTFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 8.2664713882E-003 | 6.9224832137E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
5 | CORE_MID | RunPeriod: RUNPERIOD 1 | 9.0043160726E-003 | 7.7414322673E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
6 | CORE_TOP | RunPeriod: RUNPERIOD 1 | 4.6471041935E-002 | 2.4223400622E-002 | Pass | Pass | 0.1816175443 | 0.4258882439 | Pass | Pass |
7 | PERIMETER_TOP_ZN_3 | RunPeriod: RUNPERIOD 1 | 0.1419715478 | 0.1826643813 | Pass | Pass | 0.5875805848 | 1.7623868304 | Pass | Pass |
8 | PERIMETER_TOP_ZN_2 | RunPeriod: RUNPERIOD 1 | 0.1285897014 | 0.1422629961 | Pass | Pass | 0.4903349574 | 1.5732085903 | Pass | Pass |
9 | PERIMETER_TOP_ZN_1 | RunPeriod: RUNPERIOD 1 | 9.4811798304E-002 | 0.1040149272 | Pass | Pass | 0.6118417148 | 2.6830142722 | Pass | Pass |
10 | PERIMETER_TOP_ZN_4 | RunPeriod: RUNPERIOD 1 | 0.1390216881 | 0.1447191686 | Pass | Pass | 0.4930522620 | 1.5387636793 | Pass | Pass |
11 | PERIMETER_BOT_ZN_3 | RunPeriod: RUNPERIOD 1 | 1.4085908672E-002 | 1.1711698199E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
12 | PERIMETER_BOT_ZN_2 | RunPeriod: RUNPERIOD 1 | 3.7213288550E-002 | 6.3138260373E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
13 | PERIMETER_BOT_ZN_1 | RunPeriod: RUNPERIOD 1 | 5.8272354488E-002 | 8.1172571400E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
14 | PERIMETER_BOT_ZN_4 | RunPeriod: RUNPERIOD 1 | 3.3974623365E-002 | 4.3360862914E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
15 | PERIMETER_MID_ZN_3 | RunPeriod: RUNPERIOD 1 | 1.5697816342E-002 | 1.2570004868E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
16 | PERIMETER_MID_ZN_2 | RunPeriod: RUNPERIOD 1 | 4.6477988921E-002 | 7.2542323996E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
17 | PERIMETER_MID_ZN_1 | RunPeriod: RUNPERIOD 1 | 7.6314789327E-002 | 9.9477824309E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
18 | PERIMETER_MID_ZN_4 | RunPeriod: RUNPERIOD 1 | 4.0215169036E-002 | 5.0147412068E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Heat Emission by ComponentsEnvelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
Heat Emissions [GJ] | 3109.89 | 68.18 | 0.00 | 2614.43 | 292.25 | 6084.76 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | -4.30 | 0.00 | -4.30 | Wetbulb [C] | 1.20 | 110.00 |
WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 26.40 | 9.10 | 17.00 | Wetbulb [C] | 2.10 | 90.00 |
Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
Jan | 0.00 | 0 | |||
Feb | 42.00 | 35 | |||
Mar | 0.00 | 0 | |||
Apr | 0.00 | 0 | |||
May | 40.00 | 22 | |||
Jun | 4.00 | 8 | |||
Jul | 5.00 | 4 | |||
Aug | 7.00 | 8 | |||
Sep | 17.00 | 10 | |||
Oct | 50.00 | 49 | |||
Nov | 69.00 | 59 | |||
Dec | 95.00 | 53 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
PERIMETER_TOP_PLENUM_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 0.894 | 1.032 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_TOP_PLENUM_WALL_EAST | NONRES_EXT_WALL_TOP | 0.30 | 0.894 | 1.032 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_TOP_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 0.894 | 1.032 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_TOP_PLENUM_WALL_WEST | NONRES_EXT_WALL_TOP | 0.30 | 0.894 | 1.032 | 40.57 | 40.57 | 270.00 | 90.00 | W |
BUILDING_ROOF | NONRES_ROOF | 0.30 | 0.182 | 0.186 | 1660.73 | 1660.73 | 0.00 | 0.00 | |
PERIMETER_MID_PLENUM_WALL_NORTH | NONRES_EXT_WALL_MID | 0.30 | 0.705 | 0.789 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_MID_PLENUM_WALL_EAST | NONRES_EXT_WALL_MID | 0.30 | 0.705 | 0.789 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_MID_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 0.705 | 0.789 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_MID_PLENUM_WALL_WEST | NONRES_EXT_WALL_MID | 0.30 | 0.705 | 0.789 | 40.57 | 40.57 | 270.00 | 90.00 | W |
PERIMETER_BOT_PLENUM_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.716 | 0.802 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_BOT_PLENUM_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.716 | 0.802 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_BOT_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.716 | 0.802 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_BOT_PLENUM_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.716 | 0.802 | 40.57 | 40.57 | 270.00 | 90.00 | W |
PERIMETER_TOP_ZN_3_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 0.894 | 1.032 | 136.92 | 71.65 | 0.00 | 90.00 | N |
PERIMETER_TOP_ZN_2_WALL_EAST | NONRES_EXT_WALL_TOP | 0.30 | 0.894 | 1.032 | 91.28 | 47.77 | 90.00 | 90.00 | E |
PERIMETER_TOP_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 0.894 | 1.032 | 136.92 | 71.65 | 180.00 | 90.00 | S |
PERIMETER_TOP_ZN_4_WALL_WEST | NONRES_EXT_WALL_TOP | 0.30 | 0.894 | 1.032 | 91.28 | 47.77 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_3_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.716 | 0.802 | 136.92 | 67.75 | 0.00 | 90.00 | N |
PERIMETER_BOT_ZN_3_FLOOR | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 1.00 | 0.216 | 0.224 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_BOT_ZN_2_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.716 | 0.802 | 91.28 | 45.82 | 90.00 | 90.00 | E |
PERIMETER_BOT_ZN_2_FLOOR | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 1.00 | 0.228 | 0.237 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_BOT_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.716 | 0.802 | 136.92 | 67.75 | 180.00 | 90.00 | S |
PERIMETER_BOT_ZN_1_FLOOR | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 1.00 | 0.216 | 0.224 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_BOT_ZN_4_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.716 | 0.802 | 91.28 | 45.82 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_4_FLOOR | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 1.00 | 0.228 | 0.237 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_MID_ZN_3_WALL_NORTH | NONRES_EXT_WALL_MID | 0.30 | 0.705 | 0.789 | 136.92 | 71.65 | 0.00 | 90.00 | N |
PERIMETER_MID_ZN_2_WALL_EAST | NONRES_EXT_WALL_MID | 0.30 | 0.705 | 0.789 | 91.28 | 47.77 | 90.00 | 90.00 | E |
PERIMETER_MID_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 0.705 | 0.789 | 136.92 | 71.65 | 180.00 | 90.00 | S |
PERIMETER_MID_ZN_4_WALL_WEST | NONRES_EXT_WALL_MID | 0.30 | 0.705 | 0.789 | 91.28 | 47.77 | 270.00 | 90.00 | W |
Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
CORE_BOT_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_BOT_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_BOT_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_BOT_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_BOT_ZN_5_FLOOR | CORE_BOT_ZN_5_FLOOR_FFACTOR | 1.00 | 0.006 | 0.006 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_BOT_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 225.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 135.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 45.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 315.00 | 180.00 | |
iz-CORE_TOP_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 180.00 | |
iz-PERIMETER_MID_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 180.00 | |
iz-PERIMETER_MID_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 90.00 | 180.00 | |
iz-PERIMETER_MID_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 180.00 | |
iz-PERIMETER_MID_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 270.00 | 180.00 | |
iz-CORE_MID_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_1_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_2_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 270.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_3_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_4_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 90.00 | 0.00 | |
iz-CORE_TOP_ZN_5_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 180.00 | 0.00 | |
iz-PERIMETER_BOT_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 90.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 270.00 | 180.00 | |
iz-CORE_BOT_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 180.00 | |
iz-PERIMETER_MID_ZN_1_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 0.00 | |
iz-PERIMETER_MID_ZN_2_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 270.00 | 0.00 | |
iz-PERIMETER_MID_ZN_3_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 0.00 | |
iz-PERIMETER_MID_ZN_4_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 90.00 | 0.00 | |
iz-CORE_MID_ZN_5_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 180.00 | 0.00 | |
CORE_MID_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_MID_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_MID_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_MID_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_MID_ZN_5_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_MID_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 0.00 | |
CORE_TOP_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_TOP_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_TOP_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_TOP_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_TOP_ZN_5_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_TOP_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 0.00 | |
PERIMETER_TOP_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_TOP_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_TOP_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_TOP_ZN_3_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_TOP_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 225.00 | 0.00 | |
PERIMETER_TOP_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_TOP_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_TOP_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_TOP_ZN_2_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_TOP_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 315.00 | 0.00 | |
PERIMETER_TOP_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_TOP_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_TOP_ZN_1_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_TOP_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 45.00 | 0.00 | |
PERIMETER_TOP_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_TOP_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_TOP_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_TOP_ZN_4_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_TOP_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 135.00 | 0.00 | |
PERIMETER_BOT_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_BOT_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_BOT_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_BOT_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 0.00 | |
PERIMETER_BOT_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_BOT_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_BOT_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 270.00 | 0.00 | |
PERIMETER_BOT_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_BOT_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_BOT_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 0.00 | |
PERIMETER_BOT_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_BOT_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_BOT_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_BOT_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 90.00 | 0.00 | |
PERIMETER_MID_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_MID_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_MID_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_MID_ZN_3_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_MID_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 0.00 | |
PERIMETER_MID_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_MID_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_MID_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_MID_ZN_2_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_MID_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 270.00 | 0.00 | |
PERIMETER_MID_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_MID_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_MID_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_MID_ZN_1_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_MID_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 0.00 | |
PERIMETER_MID_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_MID_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_MID_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_MID_ZN_4_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_MID_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 90.00 | 0.00 | |
CORE_BOTTOM_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
CORE_MID_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
CORE_TOP_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N |
Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | WINDOW_U_0.38_SHGC_NORTH_0.38 | 65.26 | 0.00 | 0.00 | 65.26 | 65.26 | 2.159 | 0.381 | 0.420 | No | PERIMETER_TOP_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | WINDOW_U_0.38_SHGC_EAST_0.38 | 43.51 | 0.00 | 0.00 | 43.51 | 43.51 | 2.159 | 0.381 | 0.420 | No | PERIMETER_TOP_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | WINDOW_U_0.38_SHGC_SOUTH_0.38 | 65.26 | 0.00 | 0.00 | 65.26 | 65.26 | 2.159 | 0.381 | 0.420 | No | PERIMETER_TOP_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | WINDOW_U_0.38_SHGC_WEST_0.38 | 43.51 | 0.00 | 0.00 | 43.51 | 43.51 | 2.159 | 0.381 | 0.420 | No | PERIMETER_TOP_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | WINDOW_U_0.38_SHGC_NORTH_0.38 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.159 | 0.381 | 0.420 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | WINDOW_U_0.38_SHGC_NORTH_0.38 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.159 | 0.381 | 0.420 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | WINDOW_U_0.38_SHGC_NORTH_0.38 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.159 | 0.381 | 0.420 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | WINDOW_U_0.38_SHGC_EAST_0.38 | 41.85 | 0.00 | 0.00 | 41.85 | 41.85 | 2.159 | 0.381 | 0.420 | No | PERIMETER_BOT_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | WINDOW_U_0.38_SHGC_EAST_0.38 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.159 | 0.381 | 0.420 | No | PERIMETER_BOT_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | WINDOW_U_0.38_SHGC_SOUTH_0.38 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.159 | 0.381 | 0.420 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | WINDOW_U_0.38_SHGC_SOUTH_0.38 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.159 | 0.381 | 0.420 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | WINDOW_U_0.38_SHGC_SOUTH_0.38 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.159 | 0.381 | 0.420 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | WINDOW_U_0.38_SHGC_WEST_0.38 | 41.85 | 0.00 | 0.00 | 41.85 | 41.85 | 2.159 | 0.381 | 0.420 | No | PERIMETER_BOT_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | WINDOW_U_0.38_SHGC_WEST_0.38 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.159 | 0.381 | 0.420 | No | PERIMETER_BOT_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | WINDOW_U_0.38_SHGC_NORTH_0.38 | 65.26 | 0.00 | 0.00 | 65.26 | 65.26 | 2.159 | 0.381 | 0.420 | No | PERIMETER_MID_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | WINDOW_U_0.38_SHGC_EAST_0.38 | 43.51 | 0.00 | 0.00 | 43.51 | 43.51 | 2.159 | 0.381 | 0.420 | No | PERIMETER_MID_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | WINDOW_U_0.38_SHGC_SOUTH_0.38 | 65.26 | 0.00 | 0.00 | 65.26 | 65.26 | 2.159 | 0.381 | 0.420 | No | PERIMETER_MID_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | WINDOW_U_0.38_SHGC_WEST_0.38 | 43.51 | 0.00 | 0.00 | 43.51 | 43.51 | 2.159 | 0.381 | 0.420 | No | PERIMETER_MID_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
Total or Average | 652.62 | 2.159 | 0.381 | 0.420 | |||||||||||||||||
North Total or Average | 195.79 | 2.159 | 0.381 | 0.420 | |||||||||||||||||
Non-North Total or Average | 456.84 | 2.159 | 0.381 | 0.420 |
Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
None |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 2.101 | 3.065 | 1.95 | PERIMETER_BOT_ZN_3_WALL_NORTH |
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 2.101 | 3.065 | 1.95 | PERIMETER_BOT_ZN_3_WALL_NORTH |
PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | SWINGING DOOR_CON | 2.101 | 3.065 | 1.95 | PERIMETER_BOT_ZN_2_WALL_EAST |
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | SWINGING DOOR_CON | 2.101 | 3.065 | 1.95 | PERIMETER_BOT_ZN_1_WALL_SOUTH |
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | SWINGING DOOR_CON | 2.101 | 3.065 | 1.95 | PERIMETER_BOT_ZN_1_WALL_SOUTH |
PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | SWINGING DOOR_CON | 2.101 | 3.065 | 1.95 | PERIMETER_BOT_ZN_4_WALL_WEST |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Interior LightingZone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
CORE_BOTTOM_LIGHTS | CORE_BOTTOM | CORE_BOTTOM | GENERAL | 8.6994 | 983.54 | 8556.15 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 44.78 | 0.0000 | Y | 71.93 |
CORE_MID_LIGHTS | CORE_MID | CORE_MID | GENERAL | 8.6994 | 983.54 | 8556.15 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 44.78 | 0.0000 | Y | 71.93 |
CORE_TOP_LIGHTS | CORE_TOP | CORE_TOP | GENERAL | 8.6994 | 983.54 | 8556.15 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 44.78 | 0.0000 | Y | 71.93 |
PERIMETER_TOP_ZN_3_LIGHTS | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3 | GENERAL | 8.6994 | 207.34 | 1803.71 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 27.01 | 0.0000 | Y | 9.15 |
PERIMETER_TOP_ZN_2_LIGHTS | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2 | GENERAL | 8.6994 | 131.26 | 1141.90 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 26.51 | 0.0000 | Y | 5.68 |
PERIMETER_TOP_ZN_1_LIGHTS | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1 | GENERAL | 8.6994 | 207.34 | 1803.71 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 26.23 | 0.0000 | Y | 8.88 |
PERIMETER_TOP_ZN_4_LIGHTS | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4 | GENERAL | 8.6994 | 131.25 | 1141.82 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 26.68 | 0.0000 | Y | 5.72 |
PERIMETER_BOT_ZN_3_LIGHTS | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3 | GENERAL | 8.6994 | 207.34 | 1803.71 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 26.91 | 0.0000 | Y | 9.11 |
PERIMETER_BOT_ZN_2_LIGHTS | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2 | GENERAL | 8.6994 | 131.26 | 1141.90 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 26.43 | 0.0000 | Y | 5.67 |
PERIMETER_BOT_ZN_1_LIGHTS | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1 | GENERAL | 8.6994 | 207.34 | 1803.71 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 26.17 | 0.0000 | Y | 8.86 |
PERIMETER_BOT_ZN_4_LIGHTS | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4 | GENERAL | 8.6994 | 131.25 | 1141.82 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 26.60 | 0.0000 | Y | 5.70 |
PERIMETER_MID_ZN_3_LIGHTS | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3 | GENERAL | 8.6994 | 207.34 | 1803.71 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 27.01 | 0.0000 | Y | 9.15 |
PERIMETER_MID_ZN_2_LIGHTS | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2 | GENERAL | 8.6994 | 131.26 | 1141.90 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 26.51 | 0.0000 | Y | 5.68 |
PERIMETER_MID_ZN_1_LIGHTS | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1 | GENERAL | 8.6994 | 207.34 | 1803.71 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 26.23 | 0.0000 | Y | 8.88 |
PERIMETER_MID_ZN_4_LIGHTS | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4 | GENERAL | 8.6994 | 131.25 | 1141.82 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 26.68 | 0.0000 | Y | 5.72 |
Interior Lighting Total | 8.6994 | 4982.19 | 43341.88 | 303.97 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
PERIMETER_BOT_ZN_1_DAYLREFPT1 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1803.71 | 691.72 |
PERIMETER_BOT_ZN_1_DAYLREFPT2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1803.71 | 251.62 |
PERIMETER_BOT_ZN_2_DAYLREFPT1 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1141.90 | 437.92 |
PERIMETER_BOT_ZN_2_DAYLREFPT2 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1141.90 | 159.29 |
PERIMETER_BOT_ZN_3_DAYLREFPT1 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1803.71 | 691.72 |
PERIMETER_BOT_ZN_3_DAYLREFPT2 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1803.71 | 251.62 |
PERIMETER_BOT_ZN_4_DAYLREFPT1 | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1141.82 | 437.89 |
PERIMETER_BOT_ZN_4_DAYLREFPT2 | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1141.82 | 159.28 |
PERIMETER_MID_ZN_1_DAYLREFPT1 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1803.71 | 691.72 |
PERIMETER_MID_ZN_1_DAYLREFPT2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1803.71 | 251.62 |
PERIMETER_MID_ZN_2_DAYLREFPT1 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1141.90 | 437.92 |
PERIMETER_MID_ZN_2_DAYLREFPT2 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1141.90 | 159.29 |
PERIMETER_MID_ZN_3_DAYLREFPT1 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1803.71 | 691.72 |
PERIMETER_MID_ZN_3_DAYLREFPT2 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1803.71 | 251.62 |
PERIMETER_MID_ZN_4_DAYLREFPT1 | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1141.82 | 437.89 |
PERIMETER_MID_ZN_4_DAYLREFPT2 | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1141.82 | 159.28 |
PERIMETER_TOP_ZN_1_DAYLREFPT1 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1803.71 | 691.72 |
PERIMETER_TOP_ZN_1_DAYLREFPT2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1803.71 | 251.62 |
PERIMETER_TOP_ZN_2_DAYLREFPT1 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1141.90 | 437.92 |
PERIMETER_TOP_ZN_2_DAYLREFPT2 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1141.90 | 159.29 |
PERIMETER_TOP_ZN_3_DAYLREFPT1 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1803.71 | 691.72 |
PERIMETER_TOP_ZN_3_DAYLREFPT2 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1803.71 | 251.62 |
PERIMETER_TOP_ZN_4_DAYLREFPT1 | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_DAYLCTRL | SplitFlux | Stepped | 0.38 | 1141.82 | 437.89 |
PERIMETER_TOP_ZN_4_DAYLREFPT2 | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_DAYLCTRL | SplitFlux | Stepped | 0.14 | 1141.82 | 159.28 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 563.81 | AstronomicalClock | - | 42.50 | 42.50 | 4.50 | |
EXTERIOR_LIGHTS_B | 407.66 | AstronomicalClock | - | 83.54 | 63.02 | 4.82 | |
EXTERIOR_LIGHTS_C | 4714.72 | AstronomicalClock | - | 83.54 | 47.95 | 42.44 | |
Exterior Lighting Total | 5686.19 | 51.76 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Central PlantType | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
HEATSYS1 BOILER | Boiler:HotWater | 241704.83 | 0.80 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | 79237.20 | 63441.68 | 15795.52 | 0.80 | 3.70 | |||
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | 74062.64 | 59298.64 | 14764.00 | 0.80 | 3.70 | |||
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | 82622.85 | 66152.42 | 16470.43 | 0.80 | 3.70 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
PACU_VAV_BOT COOLING COIL | 77873.7 | 3.01 | 10.26 | N/A | N/A | 11.56 | |
PACU_VAV_MID COOLING COIL | 72788.2 | 3.01 | 10.26 | N/A | N/A | 11.56 | |
PACU_VAV_TOP COOLING COIL | 81201.1 | 3.01 | 10.26 | N/A | N/A | 11.56 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | ||||||||
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | ||||||||
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | Coil:Heating:Water | 12896.73 | 12223.91 | - |
CORE_MID VAV BOX REHEAT COIL | Coil:Heating:Water | 19181.53 | 18171.74 | - |
CORE_TOP VAV BOX REHEAT COIL | Coil:Heating:Water | 30300.54 | 28715.41 | - |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Water | 13241.80 | 12546.35 | - |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Water | 8686.52 | 8230.24 | - |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 13280.65 | 12583.14 | - |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Water | 8653.23 | 8198.71 | - |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Water | 10287.83 | 9747.99 | - |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Water | 6857.07 | 6497.19 | - |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 10339.69 | 9797.13 | - |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Water | 6823.23 | 6465.13 | - |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Water | 10104.19 | 9574.07 | - |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Water | 6700.53 | 6348.92 | - |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 10140.47 | 9608.44 | - |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Water | 6666.98 | 6317.14 | - |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Water | 22102.57 | 17681.29 | - |
PACU_VAV_MID HEATING COIL | Coil:Heating:Water | 23023.16 | 18094.40 | - |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Water | 22418.10 | 18010.21 | - |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
PACU_VAV_BOT FAN | Fan:VariableVolume | 0.60 | 1314.72 | 4.79 | 10478.18 | 2189.01 | 1.00 | 1.14 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:10:00 |
PACU_VAV_MID FAN | Fan:VariableVolume | 0.60 | 1314.72 | 4.47 | 9793.91 | 2189.01 | 1.00 | 1.14 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:10:00 |
PACU_VAV_TOP FAN | Fan:VariableVolume | 0.60 | 1314.72 | 4.99 | 10925.89 | 2189.01 | 1.00 | 1.13 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
HEATSYS1 PUMP | Pump:VariableSpeed | Intermittent | 180705.70 | 0.002115 | 636.81 | 301156.09 | 0.90 | General |
SWHSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.000054 | 6.85 | 127739.32 | 0.30 | General |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SWHSYS1 WATER HEATER | WaterHeater:Mixed | 0.38 | 29307.11 | 1.00 | 27.19 | 0.85 |
DX Cooling Coil Type | Assocated Fan | Net Cooling Capacity [W] | COP [W/W] | EER [Btu/W-h] | IEER [Btu/W-h] | Supply Air Flow 100% [kg/s] | COP 75% Capacity [W/W] | EER 75% Capacity [Btu/W-h] | Supply Air Flow 75% [kg/s] | COP 50% Capacity [W/W] | EER 50% Capacity [Btu/W-h] | Supply Air Flow 50% [kg/s] | COP 25% Capacity [W/W] | EER 25% Capacity [Btu/W-h] | Supply Air Flow 25% [kg/s] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 77873.72 | 3.01 | 10.26 | 11.56 | 5.4775 | 3.31 | 11.29 | 4.3324 | 3.48 | 11.87 | 2.9040 | 3.67 | 12.54 | 1.2096 |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 72788.21 | 3.01 | 10.26 | 11.56 | 5.1198 | 3.31 | 11.29 | 4.0495 | 3.48 | 11.87 | 2.7143 | 3.67 | 12.54 | 1.1306 |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 81201.12 | 3.01 | 10.26 | 11.56 | 5.7116 | 3.31 | 11.29 | 4.5175 | 3.48 | 11.87 | 3.0280 | 3.67 | 12.54 | 1.2612 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
CORE_BOTTOM | 37193.54 | 37193.54 | 37.82 | 2.708 | 2.708 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 24.00 | 24.00 | 0.00883 | 19.67 | 0.00840 | 0.425 | 0.00 |
CORE_MID | 29932.86 | 29932.86 | 30.43 | 2.178 | 2.178 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 24.00 | 24.00 | 0.00891 | 19.67 | 0.00840 | 0.425 | 0.00 |
CORE_TOP | 29861.99 | 29861.99 | 30.36 | 2.193 | 2.193 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:10:00 | 24.00 | 24.00 | 0.00890 | 26.31 | 0.00841 | 0.425 | 0.00 |
PERIMETER_TOP_ZN_3 | 8013.77 | 8013.77 | 38.65 | 0.588 | 0.588 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:10:00 | 24.00 | 24.00 | 0.00881 | 26.31 | 0.00841 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_2 | 10714.55 | 10714.55 | 81.63 | 0.787 | 0.787 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:10:00 | 24.00 | 24.00 | 0.00865 | 21.65 | 0.00840 | 0.057 | 0.00 |
PERIMETER_TOP_ZN_1 | 16051.02 | 16051.02 | 77.41 | 1.179 | 1.179 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | 24.00 | 24.00 | 0.00866 | 26.17 | 0.00841 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_4 | 11837.17 | 11837.17 | 90.19 | 0.869 | 0.869 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 17:10:00 | 24.00 | 24.00 | 0.00863 | 24.97 | 0.00840 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_3 | 6377.68 | 6377.68 | 30.76 | 0.468 | 0.468 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:50:00 | 24.00 | 24.00 | 0.00889 | 26.40 | 0.00841 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_2 | 8776.08 | 8776.08 | 66.86 | 0.644 | 0.644 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:20:00 | 24.00 | 24.00 | 0.00868 | 21.91 | 0.00840 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_1 | 13123.80 | 13123.80 | 63.30 | 0.964 | 0.964 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 24.00 | 24.00 | 0.00869 | 26.32 | 0.00841 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_4 | 9853.42 | 9853.42 | 75.07 | 0.724 | 0.724 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 18:00:00 | 24.00 | 24.00 | 0.00866 | 24.22 | 0.00840 | 0.057 | 0.00 |
PERIMETER_MID_ZN_3 | 7159.86 | 7159.86 | 34.53 | 0.526 | 0.526 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:50:00 | 24.00 | 24.00 | 0.00885 | 26.40 | 0.00841 | 0.090 | 0.00 |
PERIMETER_MID_ZN_2 | 10790.27 | 10790.27 | 82.20 | 0.792 | 0.792 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:50:00 | 24.00 | 24.00 | 0.00865 | 21.11 | 0.00840 | 0.057 | 0.00 |
PERIMETER_MID_ZN_1 | 15052.08 | 15052.08 | 72.60 | 1.105 | 1.105 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 | 24.00 | 24.00 | 0.00867 | 26.10 | 0.00841 | 0.090 | 0.00 |
PERIMETER_MID_ZN_4 | 11114.98 | 11114.98 | 84.68 | 0.816 | 0.816 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 17:10:00 | 24.00 | 24.00 | 0.00864 | 24.97 | 0.00840 | 0.057 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
CORE_BOTTOM | 5207.87 | 5207.87 | 5.30 | 0.222 | 0.425 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00800 | -4.30 | 0.00266 | 0.425 | 0.00 |
CORE_MID | 11632.72 | 11632.72 | 11.83 | 0.496 | 0.496 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00800 | -4.30 | 0.00266 | 0.425 | 0.00 |
CORE_TOP | 21227.36 | 21227.36 | 21.58 | 0.911 | 0.911 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00800 | -4.30 | 0.00266 | 0.425 | 0.00 |
PERIMETER_TOP_ZN_3 | 9267.27 | 9267.27 | 44.70 | 0.399 | 0.399 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00792 | -4.30 | 0.00266 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_2 | 6079.04 | 6079.04 | 46.31 | 0.262 | 0.262 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00792 | -4.30 | 0.00266 | 0.057 | 0.00 |
PERIMETER_TOP_ZN_1 | 9294.43 | 9294.43 | 44.83 | 0.400 | 0.400 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00792 | -4.30 | 0.00266 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_4 | 6055.77 | 6055.77 | 46.14 | 0.261 | 0.261 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00792 | -4.30 | 0.00266 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_3 | 7201.83 | 7201.83 | 34.73 | 0.310 | 0.310 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00791 | -4.30 | 0.00266 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_2 | 4799.89 | 4799.89 | 36.57 | 0.207 | 0.207 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00791 | -4.30 | 0.00266 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_1 | 7238.09 | 7238.09 | 34.91 | 0.311 | 0.311 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00791 | -4.30 | 0.00266 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_4 | 4776.23 | 4776.23 | 36.39 | 0.206 | 0.206 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00791 | -4.30 | 0.00266 | 0.057 | 0.00 |
PERIMETER_MID_ZN_3 | 7073.85 | 7073.85 | 34.12 | 0.304 | 0.304 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00786 | -4.30 | 0.00266 | 0.090 | 0.00 |
PERIMETER_MID_ZN_2 | 4690.69 | 4690.69 | 35.74 | 0.202 | 0.202 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00787 | -4.30 | 0.00266 | 0.057 | 0.00 |
PERIMETER_MID_ZN_1 | 7099.21 | 7099.21 | 34.24 | 0.305 | 0.305 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00786 | -4.30 | 0.00266 | 0.090 | 0.00 |
PERIMETER_MID_ZN_4 | 4667.24 | 4667.24 | 35.56 | 0.201 | 0.201 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00787 | -4.30 | 0.00266 | 0.057 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PACU_VAV_BOT | 4.79 | 4.79 | 1.46 | 1.46 | 4.7867 | 1.4580 | 4.7867 | 0.3046 | 0.3000 |
PACU_VAV_MID | 4.47 | 4.47 | 1.51 | 1.51 | 4.4741 | 1.5084 | 4.4741 | 0.3371 | 0.3000 |
PACU_VAV_TOP | 4.99 | 4.99 | 2.23 | 2.23 | 4.9912 | 2.2326 | 4.9912 | 0.4473 | 0.3000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_BOTTOM VAV BOX | 12896.728 | 12896.728 | 0.771833 | 0.00011283 | 278.632 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 12896.73 | 12896.73 | 0.771833 | 12.80 | 11.50 | 0.00800000 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 0.0000 | 21.00 | 0.00800000 | 51.1678 | 5207.87 | 0.00 | 12941.74 | 12941.74 |
CORE_MID VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_MID VAV BOX | 19181.534 | 19181.534 | 0.757774 | 0.00016781 | 457.098 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 19181.53 | 19181.53 | 0.757774 | 12.80 | 11.50 | 0.00800000 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 0.0000 | 21.00 | 0.00800000 | 51.1678 | 11632.72 | 0.00 | 19243.95 | 19243.95 |
CORE_TOP VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_TOP VAV BOX | 30300.537 | 30300.537 | 0.910795 | 0.00026508 | 800.191 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 30300.54 | 30300.54 | 0.910795 | 12.80 | 11.50 | 0.00800000 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 0.0000 | 21.00 | 0.00800000 | 51.1678 | 21227.36 | 0.00 | 30407.75 | 30407.75 |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_3 VAV BOX | 13241.804 | 13241.804 | 0.399048 | 0.00011585 | 349.287 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 13241.80 | 13241.80 | 0.399048 | 12.80 | 11.50 | 0.00800000 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 0.0000 | 21.00 | 0.00792211 | 50.6769 | 9267.27 | 0.00 | 13285.72 | 13285.72 |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_2 VAV BOX | 8686.517 | 8686.517 | 0.261794 | 0.00007599 | 229.121 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 8686.52 | 8686.52 | 0.261794 | 12.80 | 11.50 | 0.00800000 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 0.0000 | 21.00 | 0.00792357 | 50.6861 | 6079.04 | 0.00 | 8715.26 | 8715.26 |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_1 VAV BOX | 13280.647 | 13280.647 | 0.400222 | 0.00011618 | 350.310 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 13280.65 | 13280.65 | 0.400222 | 12.80 | 11.50 | 0.00800000 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 0.0000 | 21.00 | 0.00792264 | 50.6802 | 9294.43 | 0.00 | 13324.69 | 13324.69 |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_4 VAV BOX | 8653.232 | 8653.232 | 0.260789 | 0.00007570 | 228.244 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 8653.23 | 8653.23 | 0.260789 | 12.80 | 11.50 | 0.00800000 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 0.0000 | 21.00 | 0.00792295 | 50.6822 | 6055.77 | 0.00 | 8681.88 | 8681.88 |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_3 VAV BOX | 10287.828 | 10287.828 | 0.309849 | 0.00009000 | 271.440 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 10287.83 | 10287.83 | 0.309849 | 12.80 | 11.50 | 0.00800000 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 0.0000 | 21.00 | 0.00790582 | 50.5741 | 7201.83 | 0.00 | 10322.47 | 10322.47 |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_2 VAV BOX | 6857.069 | 6857.069 | 0.206549 | 0.00005999 | 180.910 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6857.07 | 6857.07 | 0.206549 | 12.80 | 11.50 | 0.00800000 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 0.0000 | 21.00 | 0.00791147 | 50.6098 | 4799.89 | 0.00 | 6880.08 | 6880.08 |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_1 VAV BOX | 10339.693 | 10339.693 | 0.311414 | 0.00009046 | 272.807 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 10339.69 | 10339.69 | 0.311414 | 12.80 | 11.50 | 0.00800000 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 0.0000 | 21.00 | 0.00790691 | 50.5810 | 7238.09 | 0.00 | 10374.50 | 10374.50 |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_4 VAV BOX | 6823.227 | 6823.227 | 0.205526 | 0.00005969 | 180.018 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6823.23 | 6823.23 | 0.205526 | 12.80 | 11.50 | 0.00800000 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 0.0000 | 21.00 | 0.00791044 | 50.6032 | 4776.23 | 0.00 | 6846.13 | 6846.13 |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_3 VAV BOX | 10104.192 | 10104.192 | 0.304289 | 0.00008840 | 266.607 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 10104.19 | 10104.19 | 0.304289 | 12.80 | 11.50 | 0.00800000 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 0.0000 | 21.00 | 0.00786379 | 50.3090 | 7073.85 | 0.00 | 10138.30 | 10138.30 |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_2 VAV BOX | 6700.532 | 6700.532 | 0.201814 | 0.00005862 | 176.788 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6700.53 | 6700.53 | 0.201814 | 12.80 | 11.50 | 0.00800000 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 0.0000 | 21.00 | 0.00787055 | 50.3516 | 4690.69 | 0.00 | 6723.07 | 6723.07 |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_1 VAV BOX | 10140.473 | 10140.473 | 0.305384 | 0.00008871 | 267.563 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 10140.47 | 10140.47 | 0.305384 | 12.80 | 11.50 | 0.00800000 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 0.0000 | 21.00 | 0.00786493 | 50.3162 | 7099.21 | 0.00 | 10174.69 | 10174.69 |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_4 VAV BOX | 6666.985 | 6666.985 | 0.200800 | 0.00005833 | 175.904 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6666.98 | 6666.98 | 0.200800 | 12.80 | 11.50 | 0.00800000 | 40.00 | 21.06 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 0.0000 | 21.00 | 0.00786904 | 50.3421 | 4667.24 | 0.00 | 6689.42 | 6689.42 |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_BOT | 79237.197 | 63441.679 | 4.786719 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:10:00 | 81026.06 | 77936.22 | 4.786719 | 24.60 | 16.67 | 0.00870912 | 11.00 | 11.00 | 0.00850000 | 26.40 | 0.00840708 | 17.04 | 24.9685 | 24.00 | 0.00880966 | 46.8995 | 65171.56 | 0.00 | 81704.19 | 63960.45 |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Water | AirLoopHVAC | PACU_VAV_BOT | 22102.566 | 22102.566 | 1.436016 | 0.00019336 | 370.777 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 22:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 22102.57 | 22102.57 | 1.436016 | -0.06 | -0.43 | 0.00354774 | 12.80 | 11.50 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 83.2282 | 21.00 | 0.00795317 | 50.8725 | 20645.47 | 0.00 | 21397.04 | 21397.04 |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_MID | 74062.640 | 59298.642 | 4.474124 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:10:00 | 75759.69 | 72768.41 | 4.474124 | 24.64 | 16.69 | 0.00871751 | 11.00 | 11.00 | 0.00850000 | 26.40 | 0.00840708 | 17.04 | 26.7129 | 24.00 | 0.00883069 | 47.0099 | 60914.14 | 0.00 | 76368.52 | 59783.54 |
PACU_VAV_MID HEATING COIL | Coil:Heating:Water | AirLoopHVAC | PACU_VAV_MID | 23023.161 | 23023.161 | 1.342237 | 0.00020142 | 382.825 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 14:30:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 23023.16 | 23023.16 | 1.342237 | -1.53 | -1.72 | 0.00323700 | 12.80 | 11.50 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 89.0431 | 21.00 | 0.00794256 | 50.8056 | 26096.47 | 0.00 | 21894.60 | 21894.60 |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_TOP | 82622.853 | 66152.422 | 4.991247 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 84471.10 | 81331.19 | 4.991247 | 24.57 | 16.65 | 0.00870327 | 11.00 | 11.00 | 0.00850000 | 26.40 | 0.00840708 | 17.04 | 23.9453 | 24.00 | 0.00879666 | 46.8312 | 67893.58 | 0.00 | 85195.25 | 66693.36 |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Water | AirLoopHVAC | PACU_VAV_TOP | 22418.103 | 22418.103 | 1.497374 | 0.00019612 | 376.871 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 06:30:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 22418.10 | 22418.10 | 1.497374 | 0.29 | 0.02 | 0.00371276 | 12.80 | 11.50 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 79.8177 | 19.61 | 0.00787804 | 54.9290 | 29714.53 | 0.00 | 21795.96 | 21795.96 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
CORE_BOTTOM VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_BOTTOM VAV BOX | CORE_BOTTOM | N/A | N/A | N/A | Yes | Yes | Yes | No | 12896.728 | 12896.728 | 0.771833 | 0.00011283 | 278.632 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 5.2305 | 5.335735 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 12896.73 | 12896.73 | 1.0000 | 0.91954029 | 0.771833 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | 0.11281469 | 60.00 | 32.22 | 27.78 | 0.000 | 12896.73 | -4.30 | 0.00265759 | -4.30 | 0.00000000 | 0.0000 | 20.69 | 0.00800000 | 21.00 | 0.00800000 | 51.1678 | 5207.87 | 0.00 | 12941.74 | 12941.74 | 0.91954029 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 26.60 | 16.88 | 0.00800000 | 47134.0 | |
CORE_MID VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_MID VAV BOX | CORE_MID | N/A | N/A | N/A | Yes | Yes | Yes | No | 19181.534 | 19181.534 | 0.757774 | 0.00016781 | 457.098 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 7.7794 | 7.935934 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 19181.53 | 19181.53 | 1.0000 | 0.90279131 | 0.757774 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | 0.16779131 | 60.00 | 32.22 | 27.78 | 0.000 | 19181.53 | -4.30 | 0.00265759 | -4.30 | 0.00000000 | 0.0000 | 20.87 | 0.00800000 | 21.00 | 0.00800000 | 51.1678 | 11632.72 | 0.00 | 19243.95 | 19243.95 | 0.90279131 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 33.70 | 19.25 | 0.00800000 | 54375.9 | |
CORE_TOP VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_TOP VAV BOX | CORE_TOP | N/A | N/A | N/A | Yes | Yes | Yes | No | 30300.537 | 30300.537 | 0.910795 | 0.00026508 | 800.191 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 12.2889 | 12.536174 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 30300.54 | 30300.54 | 1.0000 | 1.08509582 | 0.910795 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | 0.26505528 | 60.00 | 32.22 | 27.78 | 0.000 | 30300.54 | -4.30 | 0.00265759 | -4.30 | 0.00000000 | 0.0000 | 20.91 | 0.00800000 | 21.00 | 0.00800000 | 51.1678 | 21227.36 | 0.00 | 30407.75 | 30407.75 | 1.08509582 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.28 | 21.27 | 0.00800000 | 61082.9 | |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_3 VAV BOX | PERIMETER_TOP_ZN_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 13241.804 | 13241.804 | 0.399048 | 0.00011585 | 349.287 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 5.3704 | 5.478502 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 13241.80 | 13241.80 | 1.0000 | 0.47541513 | 0.399048 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | 0.11583326 | 60.00 | 32.22 | 27.78 | 0.000 | 13241.80 | -4.30 | 0.00265759 | -4.30 | 0.00000000 | 0.0000 | 20.95 | 0.00792211 | 21.00 | 0.00792211 | 50.6769 | 9267.27 | 0.00 | 13285.72 | 13285.72 | 0.47541513 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.21 | 21.24 | 0.00800000 | 61005.3 | |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_2 VAV BOX | PERIMETER_TOP_ZN_2 | N/A | N/A | N/A | Yes | Yes | Yes | No | 8686.517 | 8686.517 | 0.261794 | 0.00007599 | 229.121 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 3.5230 | 3.593853 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 8686.52 | 8686.52 | 1.0000 | 0.31189406 | 0.261794 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | 0.07598569 | 60.00 | 32.22 | 27.78 | 0.000 | 8686.52 | -4.30 | 0.00265759 | -4.30 | 0.00000000 | 0.0000 | 20.95 | 0.00792357 | 21.00 | 0.00792357 | 50.6861 | 6079.04 | 0.00 | 8715.26 | 8715.26 | 0.31189406 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.20 | 21.24 | 0.00800000 | 61002.9 | |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_1 VAV BOX | PERIMETER_TOP_ZN_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 13280.647 | 13280.647 | 0.400222 | 0.00011618 | 350.310 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 5.3862 | 5.494573 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 13280.65 | 13280.65 | 1.0000 | 0.47681301 | 0.400222 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | 0.11617304 | 60.00 | 32.22 | 27.78 | 0.000 | 13280.65 | -4.30 | 0.00265759 | -4.30 | 0.00000000 | 0.0000 | 20.95 | 0.00792264 | 21.00 | 0.00792264 | 50.6802 | 9294.43 | 0.00 | 13324.69 | 13324.69 | 0.47681301 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.21 | 21.24 | 0.00800000 | 61005.1 | |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_4 VAV BOX | PERIMETER_TOP_ZN_4 | N/A | N/A | N/A | Yes | Yes | Yes | No | 8653.232 | 8653.232 | 0.260789 | 0.00007570 | 228.244 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 3.5095 | 3.580082 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 8653.23 | 8653.23 | 1.0000 | 0.31069625 | 0.260789 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | 0.07569453 | 60.00 | 32.22 | 27.78 | 0.000 | 8653.23 | -4.30 | 0.00265759 | -4.30 | 0.00000000 | 0.0000 | 20.95 | 0.00792295 | 21.00 | 0.00792295 | 50.6822 | 6055.77 | 0.00 | 8681.88 | 8681.88 | 0.31069625 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.20 | 21.24 | 0.00800000 | 61003.1 | |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_3 VAV BOX | PERIMETER_BOT_ZN_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 10287.828 | 10287.828 | 0.309849 | 0.00009000 | 271.440 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 4.1724 | 4.256360 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 10287.83 | 10287.83 | 1.0000 | 0.36914548 | 0.309849 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | 0.08999322 | 60.00 | 32.22 | 27.78 | 0.000 | 10287.83 | -4.30 | 0.00265759 | -4.30 | 0.00000000 | 0.0000 | 20.91 | 0.00790582 | 21.00 | 0.00790582 | 50.5741 | 7201.83 | 0.00 | 10322.47 | 10322.47 | 0.36914548 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.22 | 21.25 | 0.00800000 | 61023.0 | |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_2 VAV BOX | PERIMETER_BOT_ZN_2 | N/A | N/A | N/A | Yes | Yes | Yes | No | 6857.069 | 6857.069 | 0.206549 | 0.00005999 | 180.910 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 2.7810 | 2.836960 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 6857.07 | 6857.07 | 1.0000 | 0.24607623 | 0.206549 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | 0.05998251 | 60.00 | 32.22 | 27.78 | 0.000 | 6857.07 | -4.30 | 0.00265759 | -4.30 | 0.00000000 | 0.0000 | 20.95 | 0.00791147 | 21.00 | 0.00791147 | 50.6098 | 4799.89 | 0.00 | 6880.08 | 6880.08 | 0.24607623 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.22 | 21.25 | 0.00800000 | 61019.0 | |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_1 VAV BOX | PERIMETER_BOT_ZN_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 10339.693 | 10339.693 | 0.311414 | 0.00009046 | 272.807 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 4.1934 | 4.277818 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 10339.69 | 10339.69 | 1.0000 | 0.37101044 | 0.311414 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | 0.09044692 | 60.00 | 32.22 | 27.78 | 0.000 | 10339.69 | -4.30 | 0.00265759 | -4.30 | 0.00000000 | 0.0000 | 20.91 | 0.00790691 | 21.00 | 0.00790691 | 50.5810 | 7238.09 | 0.00 | 10374.50 | 10374.50 | 0.37101044 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.22 | 21.25 | 0.00800000 | 61022.6 | |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_4 VAV BOX | PERIMETER_BOT_ZN_4 | N/A | N/A | N/A | Yes | Yes | Yes | No | 6823.227 | 6823.227 | 0.205526 | 0.00005969 | 180.018 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 2.7673 | 2.822958 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 6823.23 | 6823.23 | 1.0000 | 0.24485839 | 0.205526 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | 0.05968647 | 60.00 | 32.22 | 27.78 | 0.000 | 6823.23 | -4.30 | 0.00265759 | -4.30 | 0.00000000 | 0.0000 | 20.95 | 0.00791044 | 21.00 | 0.00791044 | 50.6032 | 4776.23 | 0.00 | 6846.13 | 6846.13 | 0.24485839 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.22 | 21.25 | 0.00800000 | 61019.4 | |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_3 VAV BOX | PERIMETER_MID_ZN_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 10104.192 | 10104.192 | 0.304289 | 0.00008840 | 266.607 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 4.0979 | 4.180385 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 10104.19 | 10104.19 | 1.0000 | 0.36252155 | 0.304289 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | 0.08838686 | 60.00 | 32.22 | 27.78 | 0.000 | 10104.19 | -4.30 | 0.00265759 | -4.30 | 0.00000000 | 0.0000 | 20.91 | 0.00786379 | 21.00 | 0.00786379 | 50.3090 | 7073.85 | 0.00 | 10138.30 | 10138.30 | 0.36252155 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.23 | 21.25 | 0.00800000 | 61025.9 | |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_2 VAV BOX | PERIMETER_MID_ZN_2 | N/A | N/A | N/A | Yes | Yes | Yes | No | 6700.532 | 6700.532 | 0.201814 | 0.00005862 | 176.788 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 2.7175 | 2.772196 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 6700.53 | 6700.53 | 1.0000 | 0.24043519 | 0.201814 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | 0.05861320 | 60.00 | 32.22 | 27.78 | 0.000 | 6700.53 | -4.30 | 0.00265759 | -4.30 | 0.00000000 | 0.0000 | 20.95 | 0.00787055 | 21.00 | 0.00787055 | 50.3516 | 4690.69 | 0.00 | 6723.07 | 6723.07 | 0.24043519 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.22 | 21.25 | 0.00800000 | 61021.9 | |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_1 VAV BOX | PERIMETER_MID_ZN_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 10140.473 | 10140.473 | 0.305384 | 0.00008871 | 267.563 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 4.1126 | 4.195395 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 10140.47 | 10140.47 | 1.0000 | 0.36382610 | 0.305384 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | 0.08870423 | 60.00 | 32.22 | 27.78 | 0.000 | 10140.47 | -4.30 | 0.00265759 | -4.30 | 0.00000000 | 0.0000 | 20.91 | 0.00786493 | 21.00 | 0.00786493 | 50.3162 | 7099.21 | 0.00 | 10174.69 | 10174.69 | 0.36382610 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.23 | 21.25 | 0.00800000 | 61025.6 | |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_4 VAV BOX | PERIMETER_MID_ZN_4 | N/A | N/A | N/A | Yes | Yes | Yes | No | 6666.985 | 6666.985 | 0.200800 | 0.00005833 | 175.904 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 2.7039 | 2.758317 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 6666.98 | 6666.98 | 1.0000 | 0.23922804 | 0.200800 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 40.00 | 21.06 | 0.00800000 | 60796.0 | 0.05831974 | 60.00 | 32.22 | 27.78 | 0.000 | 6666.98 | -4.30 | 0.00265759 | -4.30 | 0.00000000 | 0.0000 | 20.95 | 0.00786904 | 21.00 | 0.00786904 | 50.3421 | 4667.24 | 0.00 | 6689.42 | 6689.42 | 0.23922804 | 12.80 | 11.60 | 0.00800000 | 33059.8 | 40.22 | 21.25 | 0.00800000 | 61022.4 | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_BOT | CORE_BOTTOM; PERIMETER_BOT_ZN_1; PERIMETER_BOT_ZN_2; PERIMETER_BOT_ZN_3; PERIMETER_BOT_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 79237.197 | 63441.679 | 4.786719 | -999.0 | -999.000 | -999.0000 | 1.01148 | 1.00000 | 1021.0298 | 1004.8586 | 1.1914 | PACU_VAV_BOT FAN | Fan:VariableVolume | 4.786719 | 5.70276313 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:10:00 | Sensible | 81026.06 | 77936.22 | 1.0226 | 5.70276313 | 4.786719 | 24.60 | 16.67 | 0.00870912 | 46896.8 | 11.00 | 11.00 | 0.00850000 | 32485.5 | -999.0 | -999.00 | -999.00 | -999.00 | 10478.181 | 70547.88 | 26.40 | 0.00840708 | 17.04 | 1.19517000 | 24.9685 | 24.00 | 0.00880966 | 24.00 | 0.00880966 | 46.8995 | 65171.56 | 0.00 | 81704.19 | 63960.45 | 5.47754709 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.26 | 14.43 | 0.00991458 | 40406.2 | |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | PACU_VAV_BOT | CORE_BOTTOM; PERIMETER_BOT_ZN_1; PERIMETER_BOT_ZN_2; PERIMETER_BOT_ZN_3; PERIMETER_BOT_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 22102.566 | 22102.566 | 1.436016 | 0.00019336 | 370.777 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PACU_VAV_BOT FAN | Fan:VariableVolume | 4.786719 | 5.70276313 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 8.9640 | 9.144445 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 22:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 22102.57 | 22102.57 | 1.0000 | 1.71082894 | 1.436016 | -0.06 | -0.43 | 0.00354774 | 8815.3 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 0.19334316 | 60.00 | 32.22 | 27.78 | 0.000 | 22102.57 | -4.30 | 0.00265759 | -4.30 | 1.19517000 | 83.2282 | 21.00 | 0.00796502 | 21.00 | 0.00795317 | 50.8725 | 20645.47 | 0.00 | 21397.04 | 21397.04 | 1.71082894 | 2.80 | 1.31 | 0.00354774 | 11704.7 | 15.17 | 7.78 | 0.00354774 | 24211.5 | |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_MID | CORE_MID; PERIMETER_MID_ZN_1; PERIMETER_MID_ZN_2; PERIMETER_MID_ZN_3; PERIMETER_MID_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 74062.640 | 59298.642 | 4.474124 | -999.0 | -999.000 | -999.0000 | 1.00748 | 1.00000 | 1021.0454 | 1004.8586 | 1.1914 | PACU_VAV_MID FAN | Fan:VariableVolume | 4.474124 | 5.33034618 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:10:00 | Sensible | 75759.69 | 72768.41 | 1.0229 | 5.33034618 | 4.474124 | 24.64 | 16.69 | 0.00871751 | 46960.9 | 11.00 | 11.00 | 0.00850000 | 32485.5 | -999.0 | -999.00 | -999.00 | -999.00 | 9793.907 | 65965.78 | 26.40 | 0.00840708 | 17.04 | 1.19517000 | 26.7129 | 24.00 | 0.00883069 | 24.00 | 0.00883069 | 47.0099 | 60914.14 | 0.00 | 76368.52 | 59783.54 | 5.11983780 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.26 | 14.43 | 0.00991458 | 40406.2 | |
PACU_VAV_MID HEATING COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | PACU_VAV_MID | CORE_MID; PERIMETER_MID_ZN_1; PERIMETER_MID_ZN_2; PERIMETER_MID_ZN_3; PERIMETER_MID_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 23023.161 | 23023.161 | 1.342237 | 0.00020142 | 382.825 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PACU_VAV_MID FAN | Fan:VariableVolume | 4.474124 | 5.33034618 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 9.3374 | 9.525321 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 14:30:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 23023.16 | 23023.16 | 1.0000 | 1.59910386 | 1.342237 | -1.53 | -1.72 | 0.00323700 | 6551.0 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 0.20139611 | 60.00 | 32.22 | 27.78 | 0.000 | 23023.16 | -4.30 | 0.00265759 | -4.30 | 1.19517000 | 89.0431 | 21.00 | 0.00794567 | 21.00 | 0.00794256 | 50.8056 | 26096.47 | 0.00 | 21894.60 | 21894.60 | 1.59910386 | 2.80 | 0.87 | 0.00323700 | 10925.9 | 16.34 | 7.98 | 0.00323700 | 24617.7 | |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_TOP | CORE_TOP; PERIMETER_TOP_ZN_1; PERIMETER_TOP_ZN_2; PERIMETER_TOP_ZN_3; PERIMETER_TOP_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 82622.853 | 66152.422 | 4.991247 | -999.0 | -999.000 | -999.0000 | 1.01396 | 1.00000 | 1021.0189 | 1004.8586 | 1.1914 | PACU_VAV_TOP FAN | Fan:VariableVolume | 4.991247 | 5.94643147 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | Sensible | 84471.10 | 81331.19 | 1.0224 | 5.94643147 | 4.991247 | 24.57 | 16.65 | 0.00870327 | 46857.3 | 11.00 | 11.00 | 0.00850000 | 32485.5 | -999.0 | -999.00 | -999.00 | -999.00 | 10925.894 | 73545.21 | 26.40 | 0.00840708 | 17.04 | 1.19517000 | 23.9453 | 24.00 | 0.00879666 | 24.00 | 0.00879666 | 46.8312 | 67893.58 | 0.00 | 85195.25 | 66693.36 | 5.71159238 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 15.26 | 14.43 | 0.00991458 | 40406.2 | |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | PACU_VAV_TOP | CORE_TOP; PERIMETER_TOP_ZN_1; PERIMETER_TOP_ZN_2; PERIMETER_TOP_ZN_3; PERIMETER_TOP_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 22418.103 | 22418.103 | 1.497374 | 0.00019612 | 376.871 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PACU_VAV_TOP FAN | Fan:VariableVolume | 4.991247 | 5.94643147 | 4197.9300 | 999.8980 | 2.11432357 | 54.44 | 82.22 | 27.78 | 246569.23 | 9.0920 | 9.274992 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 06:30:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 22418.10 | 22418.10 | 1.0000 | 1.78392944 | 1.497374 | 0.29 | 0.02 | 0.00371276 | 9582.9 | 12.80 | 11.50 | 0.00800000 | 33059.8 | 0.19610334 | 60.00 | 32.22 | 27.78 | 0.000 | 22418.10 | -4.30 | 0.00265759 | -4.30 | 1.19517000 | 79.8177 | 18.46 | 0.00788579 | 19.61 | 0.00787804 | 54.9290 | 29714.53 | 0.00 | 21795.96 | 21795.96 | 1.78392944 | 2.80 | 1.54 | 0.00371276 | 12118.3 | 14.88 | 7.84 | 0.00371276 | 24336.2 |
Report: System Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PACU_VAV_BOT_OA_CONTROLLER | DifferentialDryBulb | 0.00 | 4.79 | - | |||
PACU_VAV_MID_OA_CONTROLLER | DifferentialDryBulb | 0.00 | 4.47 | - | |||
PACU_VAV_TOP_OA_CONTROLLER | DifferentialDryBulb | 0.00 | 4.99 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
CORE_BOTTOM | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORE_MID | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORE_TOP | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_3 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_2 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_1 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_4 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
CORE_BOTTOM | 1786.83 | 2363.17 | 12.00 |
CORE_MID | 904.50 | 3779.00 | 99.83 |
CORE_TOP | 1258.50 | 4399.00 | 646.33 |
PERIMETER_TOP_ZN_3 | 2214.83 | 4733.83 | 1648.83 |
PERIMETER_TOP_ZN_2 | 2648.67 | 4237.00 | 1528.17 |
PERIMETER_TOP_ZN_1 | 2475.67 | 4211.00 | 1322.17 |
PERIMETER_TOP_ZN_4 | 2527.33 | 4627.50 | 1635.33 |
PERIMETER_BOT_ZN_3 | 1471.00 | 4895.00 | 1143.83 |
PERIMETER_BOT_ZN_2 | 2152.50 | 3934.33 | 964.00 |
PERIMETER_BOT_ZN_1 | 1990.67 | 4297.50 | 976.00 |
PERIMETER_BOT_ZN_4 | 2076.33 | 4291.50 | 1056.83 |
PERIMETER_MID_ZN_3 | 1603.33 | 4413.83 | 985.17 |
PERIMETER_MID_ZN_2 | 1791.50 | 3561.00 | 894.50 |
PERIMETER_MID_ZN_1 | 2005.50 | 3878.17 | 713.67 |
PERIMETER_MID_ZN_4 | 2022.83 | 4348.67 | 987.33 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
Facility | 4227.00 | 5224.33 | 1952.33 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
CORE_BOTTOM | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 0.83 | 0.00 | 0.83 | 0.00 |
CORE_TOP | 2.33 | 0.00 | 2.33 | 0.00 |
PERIMETER_TOP_ZN_3 | 20.00 | 0.00 | 17.33 | 0.00 |
PERIMETER_TOP_ZN_2 | 8.17 | 8.83 | 6.33 | 8.83 |
PERIMETER_TOP_ZN_1 | 4.67 | 14.50 | 4.00 | 14.50 |
PERIMETER_TOP_ZN_4 | 7.50 | 17.17 | 5.67 | 9.50 |
PERIMETER_BOT_ZN_3 | 2.50 | 0.00 | 2.33 | 0.00 |
PERIMETER_BOT_ZN_2 | 0.33 | 4.17 | 0.33 | 4.17 |
PERIMETER_BOT_ZN_1 | 367.50 | 7.67 | 367.50 | 7.67 |
PERIMETER_BOT_ZN_4 | 0.33 | 10.00 | 0.33 | 5.00 |
PERIMETER_MID_ZN_3 | 3.00 | 0.00 | 2.83 | 0.00 |
PERIMETER_MID_ZN_2 | 1.17 | 12.83 | 1.00 | 12.83 |
PERIMETER_MID_ZN_1 | 0.33 | 16.00 | 0.33 | 16.00 |
PERIMETER_MID_ZN_4 | 1.17 | 16.33 | 1.00 | 9.67 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 381.50 | 89.00 | 378.17 | 72.17 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
CORE_BOTTOM | 21.52 | 52.94 | 2698.04 | 0.984 | 0.000 | 0.000 | 0.000 |
CORE_MID | 21.52 | 52.94 | 2698.04 | 0.697 | 0.000 | 0.000 | 0.000 |
CORE_TOP | 21.52 | 52.94 | 2698.04 | 0.671 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_3 | 4.54 | 11.16 | 568.77 | 0.698 | 0.022 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_2 | 2.87 | 7.07 | 360.08 | 1.210 | 0.023 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_1 | 4.54 | 11.16 | 568.77 | 1.269 | 0.022 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_4 | 2.87 | 7.06 | 360.05 | 1.288 | 0.023 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_3 | 4.54 | 11.16 | 568.77 | 0.640 | 0.012 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_2 | 2.87 | 7.07 | 360.08 | 1.055 | 0.012 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_1 | 4.54 | 11.16 | 568.77 | 1.001 | 0.826 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_4 | 2.87 | 7.06 | 360.05 | 1.081 | 0.012 | 0.000 | 0.000 |
PERIMETER_MID_ZN_3 | 4.54 | 11.16 | 568.77 | 0.713 | 0.018 | 0.000 | 0.000 |
PERIMETER_MID_ZN_2 | 2.51 | 7.07 | 360.08 | 1.144 | 0.020 | 0.000 | 0.000 |
PERIMETER_MID_ZN_1 | 4.54 | 11.16 | 568.77 | 1.277 | 0.018 | 0.000 | 0.000 |
PERIMETER_MID_ZN_4 | 2.87 | 7.06 | 360.05 | 1.270 | 0.019 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
CORE_BOTTOM | 21.52 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
CORE_MID | 21.52 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
CORE_TOP | 21.52 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_3 | 4.54 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_2 | 2.87 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_1 | 4.54 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_4 | 2.87 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_3 | 4.54 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_2 | 2.87 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_1 | 4.54 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_4 | 2.87 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_3 | 4.54 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_2 | 2.51 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_1 | 4.54 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_4 | 2.87 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Mechanical Ventilation Parameters by ZoneAirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
CORE_BOTTOM | PACU_VAV_BOT | 21.52 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
CORE_MID | PACU_VAV_MID | 21.52 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
CORE_TOP | PACU_VAV_TOP | 21.52 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | 4.54 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | 2.87 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | 4.54 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | 2.87 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | 4.54 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | 2.87 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | 4.54 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | 2.87 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | 4.54 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | 2.51 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | 4.54 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | 2.87 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
Total Facility | 108.66 | 268.17 | 13667.13 | 4982.19 | 0.0000 | 2.151 |
Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
CORE_BOTTOM | 15542150.01 | 0.00 | 15542150.01 | 0.00 | 15542150.01 | 13393058.27 | 5200.39 | 53.39 | 3506.22 | 28.67 |
CORE_MID | 11076715.06 | 0.00 | 11076715.06 | 0.00 | 11076715.06 | 13393058.27 | 6034.45 | 56.08 | 2669.47 | 36.92 |
CORE_TOP | 10667779.09 | 0.00 | 10667779.09 | 0.00 | 10667779.09 | 13393058.27 | 6098.99 | 57.76 | 2603.24 | 46.77 |
PERIMETER_TOP_ZN_3 | 2341019.94 | 0.00 | 2341019.94 | 147358.57 | 2488378.50 | 2823374.22 | 6043.64 | 61.41 | 2654.95 | 46.77 |
PERIMETER_TOP_ZN_2 | 2566024.46 | 0.00 | 2566024.46 | 98238.45 | 2664262.91 | 1787429.43 | 4099.46 | 4.66 | 4655.88 | 46.77 |
PERIMETER_TOP_ZN_1 | 4244381.92 | 0.00 | 4244381.92 | 147358.57 | 4391740.48 | 2823374.22 | 4109.24 | 1.86 | 4648.90 | 46.77 |
PERIMETER_TOP_ZN_4 | 2741144.65 | 0.00 | 2741144.65 | 98238.45 | 2839383.10 | 1787312.18 | 4079.50 | 2.73 | 4677.77 | 46.77 |
PERIMETER_BOT_ZN_3 | 2146144.56 | 0.00 | 2146144.56 | 78349.72 | 2224494.28 | 2823374.22 | 5825.97 | 77.98 | 2856.05 | 28.67 |
PERIMETER_BOT_ZN_2 | 2231855.09 | 0.00 | 2231855.09 | 52232.83 | 2284087.92 | 1787429.43 | 4088.95 | 7.82 | 4663.22 | 28.67 |
PERIMETER_BOT_ZN_1 | 3351609.34 | 0.00 | 3351609.34 | 2809393.29 | 6161002.63 | 2823374.22 | 4104.02 | 17.84 | 4638.14 | 28.67 |
PERIMETER_BOT_ZN_4 | 2291110.14 | 0.00 | 2291110.14 | 52232.83 | 2343342.97 | 1787312.18 | 4053.01 | 7.03 | 4699.96 | 28.67 |
PERIMETER_MID_ZN_3 | 2390738.18 | 0.00 | 2390738.18 | 122664.65 | 2513402.83 | 2823374.22 | 6002.75 | 59.64 | 2697.61 | 36.92 |
PERIMETER_MID_ZN_2 | 2655737.72 | 0.00 | 2655737.72 | 81775.94 | 2737513.66 | 1787429.43 | 4012.11 | 4.48 | 4743.41 | 945.92 |
PERIMETER_MID_ZN_1 | 4268675.32 | 0.00 | 4268675.32 | 122664.65 | 4391339.97 | 2823374.22 | 4040.31 | 4.40 | 4715.29 | 36.92 |
PERIMETER_MID_ZN_4 | 2698246.12 | 0.00 | 2698246.12 | 81775.94 | 2780022.07 | 1787312.18 | 4002.28 | 5.92 | 4751.80 | 36.92 |
Total Facility | 71213331.59 | 0.00 | 71213331.59 | 3892283.91 | 75105615.50 | 67843644.98 | 6249.24 | 273.93 | 4813.28 | 970.49 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
CORE_BOTTOM | 0.7230 | 0.0000 | 0.7230 | 0.0000 | 0.7230 | 0.4247 | 2411.22 | 53.39 | 3478.39 |
CORE_MID | 0.5134 | 0.0000 | 0.5134 | 0.0000 | 0.5134 | 0.4247 | 3253.54 | 56.08 | 2633.39 |
CORE_TOP | 0.4942 | 0.0000 | 0.4942 | 0.0000 | 0.4942 | 0.4247 | 3317.16 | 57.76 | 2568.08 |
PERIMETER_TOP_ZN_3 | 0.1085 | 0.0000 | 0.1085 | 0.0034 | 0.1119 | 0.0895 | 3261.81 | 61.41 | 2619.78 |
PERIMETER_TOP_ZN_2 | 0.1190 | 0.0000 | 0.1190 | 0.0023 | 0.1213 | 0.0567 | 1317.63 | 4.66 | 4620.71 |
PERIMETER_TOP_ZN_1 | 0.1970 | 0.0000 | 0.1970 | 0.0034 | 0.2005 | 0.0895 | 1327.41 | 1.86 | 4613.73 |
PERIMETER_TOP_ZN_4 | 0.1268 | 0.0000 | 0.1268 | 0.0023 | 0.1291 | 0.0567 | 1297.66 | 2.73 | 4642.60 |
PERIMETER_BOT_ZN_3 | 0.0996 | 0.0000 | 0.0996 | 0.0018 | 0.1014 | 0.0895 | 3036.80 | 77.98 | 2828.22 |
PERIMETER_BOT_ZN_2 | 0.1037 | 0.0000 | 0.1037 | 0.0012 | 0.1050 | 0.0567 | 1299.83 | 7.82 | 4635.35 |
PERIMETER_BOT_ZN_1 | 0.1558 | 0.0000 | 0.1558 | 0.1295 | 0.2853 | 0.0895 | 1314.85 | 17.84 | 4610.31 |
PERIMETER_BOT_ZN_4 | 0.1063 | 0.0000 | 0.1063 | 0.0012 | 0.1075 | 0.0567 | 1263.89 | 7.03 | 4672.08 |
PERIMETER_MID_ZN_3 | 0.1108 | 0.0000 | 0.1108 | 0.0028 | 0.1137 | 0.0895 | 3221.83 | 59.64 | 2661.52 |
PERIMETER_MID_ZN_2 | 0.1125 | 0.0000 | 0.1125 | 0.0020 | 0.1145 | 0.0567 | 1231.20 | 4.48 | 3798.32 |
PERIMETER_MID_ZN_1 | 0.1983 | 0.0000 | 0.1983 | 0.0028 | 0.2011 | 0.0895 | 1259.39 | 4.40 | 4679.21 |
PERIMETER_MID_ZN_4 | 0.1249 | 0.0000 | 0.1249 | 0.0019 | 0.1268 | 0.0567 | 1221.37 | 5.92 | 4715.72 |
Total Facility | 3.2940 | 0.0000 | 3.2940 | 0.1546 | 3.4486 | 2.1513 | 3444.41 | 273.93 | 4764.01 |
Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
PACU_VAV_BOT | 36283099.76 | 0.00 | 36283099.76 | 22614548.33 | 4025.78 | 6.92 | 4727.30 | 28.67 |
PACU_VAV_MID | 32773349.77 | 0.00 | 32773349.77 | 22614548.33 | 4003.09 | 5.81 | 4751.10 | 36.92 |
PACU_VAV_TOP | 32021422.45 | 0.00 | 32021422.45 | 22614548.33 | 4086.28 | 4.61 | 4669.11 | 46.77 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
PACU_VAV_BOT | 1.6868 | 0.0000 | 1.6868 | 0.7171 | 1236.61 | 6.92 | 4699.47 |
PACU_VAV_MID | 1.5197 | 0.0000 | 1.5197 | 0.7171 | 1222.17 | 5.81 | 4715.01 |
PACU_VAV_TOP | 1.4841 | 0.0000 | 1.4841 | 0.7171 | 1304.45 | 4.61 | 4633.95 |
No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
PACU_VAV_BOT | 0.00 | 0.00 | 3530.97 | 0.00 | 0.00 | 0.00 | 1258.18 | 0.00 | 0.00 | 0.00 |
PACU_VAV_MID | 0.00 | 0.00 | 3104.97 | 0.00 | 0.00 | 0.00 | 1730.72 | 0.00 | 0.00 | 0.00 |
PACU_VAV_TOP | 0.00 | 0.00 | 3047.47 | 0.00 | 0.00 | 0.00 | 1777.67 | 0.00 | 0.00 | 0.00 |
No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
PACU_VAV_BOT | 0.0000 | 0.0000 | 2.4663 | 0.0000 | 0.0000 | 0.0000 | 1.1030 | 0.0000 | 0.0000 | 0.0000 |
PACU_VAV_MID | 0.0000 | 0.0000 | 2.3194 | 0.0000 | 0.0000 | 0.0000 | 1.1071 | 0.0000 | 0.0000 | 0.0000 |
PACU_VAV_TOP | 0.0000 | 0.0000 | 2.2866 | 0.0000 | 0.0000 | 0.0000 | 1.1030 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Surfaces by ClassTotal | Outdoors | |
Wall | 72 | 24 |
Floor | 30 | 4 |
Roof | 26 | 1 |
Internal Mass | 15 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 18 | 18 |
Door | 6 | 6 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 3 |
Conditioned Zones | 18 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 3 |
Count | |
IDF Objects | 982 |
Defaulted Fields | 577 |
Fields with Defaults | 2420 |
Autosized Fields | 193 |
Autosizable Fields | 250 |
Autocalculated Fields | 156 |
Autocalculatable Fields | 277 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1274.46 | 13834.26 | 29-MAY-17:40 | 136967.67 | 13-JUN-15:30 |
Electricity:Building | 1023.66 | 13465.67 | 16-APR-17:20 | 74341.76 | 02-JAN-08:10 |
Electricity:Zone:CORE_BOTTOM | 322.35 | 5243.28 | 01-JAN-00:10 | 20463.73 | 02-JAN-08:10 |
Electricity:SpaceType:GENERAL | 1023.66 | 13465.67 | 16-APR-17:20 | 74341.76 | 02-JAN-08:10 |
InteriorLights:Electricity | 303.97 | 987.92 | 16-APR-17:20 | 32642.50 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_BOTTOM | 71.93 | 211.73 | 01-JAN-00:10 | 6443.98 | 02-JAN-08:10 |
InteriorLights:Electricity:SpaceType:GENERAL | 303.97 | 987.92 | 16-APR-17:20 | 32642.50 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity | 303.97 | 987.92 | 16-APR-17:20 | 32642.50 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_BOTTOM | 71.93 | 211.73 | 01-JAN-00:10 | 6443.98 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 303.97 | 987.92 | 16-APR-17:20 | 32642.50 | 02-JAN-08:10 |
Electricity:Zone:CORE_MID | 187.35 | 2043.28 | 01-JAN-00:10 | 13252.30 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_MID | 71.93 | 211.73 | 01-JAN-00:10 | 6443.98 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_MID | 71.93 | 211.73 | 01-JAN-00:10 | 6443.98 | 02-JAN-08:10 |
Electricity:Zone:CORE_TOP | 187.35 | 2043.28 | 01-JAN-00:10 | 13252.30 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_TOP | 71.93 | 211.73 | 01-JAN-00:10 | 6443.98 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_TOP | 71.93 | 211.73 | 01-JAN-00:10 | 6443.98 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_TOP_ZN_3 | 33.48 | 422.10 | 02-APR-17:10 | 2793.69 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_3 | 9.15 | 36.00 | 01-JAN-10:50 | 1358.45 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_3 | 9.15 | 36.00 | 01-JAN-10:50 | 1358.45 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_TOP_ZN_2 | 21.09 | 267.21 | 16-APR-17:10 | 1768.58 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_2 | 5.68 | 22.79 | 01-JAN-08:40 | 860.01 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_2 | 5.68 | 22.79 | 01-JAN-08:40 | 860.01 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_TOP_ZN_1 | 33.21 | 422.10 | 02-APR-17:10 | 2793.68 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_1 | 8.88 | 36.00 | 01-JAN-08:40 | 1358.45 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_1 | 8.88 | 36.00 | 01-JAN-08:40 | 1358.45 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_TOP_ZN_4 | 21.12 | 267.21 | 12-MAR-17:10 | 1768.52 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_4 | 5.72 | 22.79 | 01-JAN-10:30 | 859.95 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_4 | 5.72 | 22.79 | 01-JAN-10:30 | 859.95 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_BOT_ZN_3 | 33.44 | 422.10 | 02-APR-17:10 | 2793.69 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_3 | 9.11 | 36.00 | 01-JAN-10:40 | 1358.45 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_3 | 9.11 | 36.00 | 01-JAN-10:40 | 1358.45 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_BOT_ZN_2 | 21.07 | 267.21 | 16-APR-17:10 | 1768.58 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_2 | 5.67 | 22.79 | 01-JAN-08:40 | 860.01 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_2 | 5.67 | 22.79 | 01-JAN-08:40 | 860.01 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_BOT_ZN_1 | 33.19 | 422.10 | 02-APR-17:10 | 2793.68 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_1 | 8.86 | 36.00 | 01-JAN-08:40 | 1358.45 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_1 | 8.86 | 36.00 | 01-JAN-08:40 | 1358.45 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_BOT_ZN_4 | 21.10 | 267.21 | 12-MAR-17:10 | 1768.52 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_4 | 5.70 | 22.79 | 01-JAN-10:30 | 859.95 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_4 | 5.70 | 22.79 | 01-JAN-10:30 | 859.95 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_MID_ZN_3 | 33.48 | 422.10 | 02-APR-17:10 | 2793.69 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_3 | 9.15 | 36.00 | 01-JAN-10:50 | 1358.45 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_3 | 9.15 | 36.00 | 01-JAN-10:50 | 1358.45 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_MID_ZN_2 | 21.09 | 267.21 | 16-APR-17:10 | 1768.58 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_2 | 5.68 | 22.79 | 01-JAN-08:40 | 860.01 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_2 | 5.68 | 22.79 | 01-JAN-08:40 | 860.01 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_MID_ZN_1 | 33.21 | 422.10 | 02-APR-17:10 | 2793.68 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_1 | 8.88 | 36.00 | 01-JAN-08:40 | 1358.45 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_1 | 8.88 | 36.00 | 01-JAN-08:40 | 1358.45 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_MID_ZN_4 | 21.12 | 267.21 | 12-MAR-17:10 | 1768.52 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_4 | 5.72 | 22.79 | 01-JAN-10:30 | 859.95 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_4 | 5.72 | 22.79 | 01-JAN-10:30 | 859.95 | 02-JAN-08:10 |
InteriorEquipment:Electricity | 719.69 | 12477.75 | 01-JAN-00:10 | 41699.26 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 250.42 | 5031.54 | 01-JAN-00:10 | 14019.75 | 02-JAN-08:10 |
InteriorEquipment:Electricity:SpaceType:GENERAL | 719.69 | 12477.75 | 01-JAN-00:10 | 41699.26 | 02-JAN-08:10 |
ElevatorLift:InteriorEquipment:Electricity | 134.36 | 3200.00 | 01-JAN-00:10 | 7125.18 | 02-JAN-07:10 |
ElevatorLift:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 134.36 | 3200.00 | 01-JAN-00:10 | 7125.18 | 02-JAN-07:10 |
ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 134.36 | 3200.00 | 01-JAN-00:10 | 7125.18 | 02-JAN-07:10 |
ElevatorLightsFan:InteriorEquipment:Electricity | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
ElevatorLightsFan:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity | 584.69 | 9277.75 | 01-JAN-00:10 | 34487.83 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 584.69 | 9277.75 | 01-JAN-00:10 | 34487.83 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_MID | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_MID | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_TOP | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_TOP | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
Electricity:HVAC | 141.21 | 367.92 | 01-JAN-00:10 | 64980.01 | 13-JUN-15:30 |
ExteriorEquipment:Electricity | 26.90 | 367.92 | 01-JAN-00:10 | 1410.29 | 02-JAN-08:20 |
Transformer:ExteriorEquipment:Electricity | 26.90 | 367.92 | 01-JAN-00:10 | 1410.29 | 02-JAN-08:20 |
ElectricityPurchased:Facility | 1274.46 | 13834.26 | 29-MAY-17:40 | 136967.67 | 13-JUN-15:30 |
ElectricityPurchased:Plant | 1274.46 | 13834.26 | 29-MAY-17:40 | 136967.67 | 13-JUN-15:30 |
Cogeneration:ElectricityPurchased | 1274.46 | 13834.26 | 29-MAY-17:40 | 136967.67 | 13-JUN-15:30 |
General:Cogeneration:ElectricityPurchased | 1274.46 | 13834.26 | 29-MAY-17:40 | 136967.67 | 13-JUN-15:30 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1274.46 | 13834.26 | 29-MAY-17:40 | 136967.67 | 13-JUN-15:30 |
ElectricityNet:Plant | 1274.46 | 13834.26 | 29-MAY-17:40 | 136967.67 | 13-JUN-15:30 |
Cogeneration:ElectricityNet | 1274.46 | 13834.26 | 29-MAY-17:40 | 136967.67 | 13-JUN-15:30 |
General:Cogeneration:ElectricityNet | 1274.46 | 13834.26 | 29-MAY-17:40 | 136967.67 | 13-JUN-15:30 |
Fans:Electricity | 75.99 | 0.00 | 01-JAN-00:10 | 22047.46 | 13-JUN-15:30 |
General:Fans:Electricity | 75.99 | 0.00 | 01-JAN-00:10 | 22047.46 | 13-JUN-15:30 |
ExteriorLights:Electricity | 51.76 | 0.00 | 01-JAN-08:20 | 5686.19 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 51.76 | 0.00 | 01-JAN-08:20 | 5686.19 | 01-JAN-06:10 |
Cooling:Electricity | 38.31 | 0.00 | 01-JAN-00:10 | 41647.56 | 13-JUN-16:00 |
General:Cooling:Electricity | 38.31 | 0.00 | 01-JAN-00:10 | 41647.56 | 13-JUN-16:00 |
Electricity:Plant | 57.83 | 0.00 | 01-JAN-00:10 | 6980.40 | 10-JAN-12:40 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:Electricity | 56.54 | 0.00 | 01-JAN-00:10 | 6667.55 | 13-FEB-12:30 |
Water Heater:WaterSystems:Electricity | 56.54 | 0.00 | 01-JAN-00:10 | 6667.55 | 13-FEB-12:30 |
Pumps:Electricity | 1.29 | 0.00 | 01-JAN-00:10 | 552.07 | 10-JAN-07:30 |
General:Pumps:Electricity | 1.29 | 0.00 | 01-JAN-00:10 | 552.07 | 10-JAN-07:30 |
WIRED_LTG_ELECTRICITY | 8.54 | 0.00 | 01-JAN-00:10 | 917.25 | 02-JAN-08:20 |
WIRED_INT_EQUIP1 | 680.83 | 12477.75 | 01-JAN-00:10 | 37555.83 | 02-JAN-13:10 |
WIRED_INT_EQUIP2 | 624.19 | 9277.75 | 01-JAN-00:10 | 39135.32 | 02-JAN-08:10 |
Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
NaturalGas:Facility | 263.87 | 0.00 | 01-JAN-00:10 | 174236.85 | 10-JAN-07:10 |
NaturalGas:Plant | 263.87 | 0.00 | 01-JAN-00:10 | 174236.85 | 10-JAN-07:10 |
Heating:NaturalGas | 263.87 | 0.00 | 01-JAN-00:10 | 174236.85 | 10-JAN-07:10 |
Boiler:Heating:NaturalGas | 263.87 | 0.00 | 01-JAN-00:10 | 174236.85 | 10-JAN-07:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:20 |
Water:Plant | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:20 |
WaterSystems:Water | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:20 |
WaterUse:WaterSystems:Water | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:20 |
MainsWater:Facility | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:20 |
MainsWater:Plant | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:20 |
WaterSystems:MainsWater | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:20 |
WaterUse:WaterSystems:MainsWater | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:20 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
EnergyTransfer:Facility | 1506.06 | 0.00 | 01-JAN-00:10 | 375305.11 | 02-JAN-07:20 |
EnergyTransfer:Building | 926.43 | 0.00 | 01-JAN-00:10 | 144831.88 | 13-JUN-15:40 |
EnergyTransfer:Zone:CORE_BOTTOM | 209.31 | 0.00 | 01-JAN-00:10 | 23424.94 | 24-JUL-16:00 |
Heating:EnergyTransfer | 72.95 | 0.00 | 01-JAN-00:10 | 100914.67 | 02-JAN-06:10 |
Heating:EnergyTransfer:Zone:CORE_BOTTOM | 0.00 | 0.00 | 01-JAN-00:10 | 1217.38 | 02-JAN-07:10 |
General:Heating:EnergyTransfer | 72.95 | 0.00 | 01-JAN-00:10 | 100914.67 | 02-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:CORE_BOTTOM | 0.00 | 0.00 | 01-JAN-00:10 | 1217.38 | 02-JAN-07:10 |
Cooling:EnergyTransfer | 853.47 | 0.00 | 01-JAN-00:10 | 144831.88 | 13-JUN-15:40 |
Cooling:EnergyTransfer:Zone:CORE_BOTTOM | 209.31 | 0.00 | 01-JAN-00:10 | 23424.94 | 24-JUL-16:00 |
General:Cooling:EnergyTransfer | 853.47 | 0.00 | 01-JAN-00:10 | 144831.88 | 13-JUN-15:40 |
General:Cooling:EnergyTransfer:Zone:CORE_BOTTOM | 209.31 | 0.00 | 01-JAN-00:10 | 23424.94 | 24-JUL-16:00 |
EnergyTransfer:Zone:TOPFLOOR_PLENUM | 35.61 | 0.00 | 01-JAN-00:10 | 10286.72 | 09-JAN-06:20 |
Heating:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 16.11 | 0.00 | 01-JAN-00:10 | 10286.72 | 09-JAN-06:20 |
General:Heating:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 16.11 | 0.00 | 01-JAN-00:10 | 10286.72 | 09-JAN-06:20 |
Cooling:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 19.50 | 0.00 | 01-JAN-00:10 | 8958.91 | 13-JUN-14:30 |
General:Cooling:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 19.50 | 0.00 | 01-JAN-00:10 | 8958.91 | 13-JUN-14:30 |
EnergyTransfer:Zone:MIDFLOOR_PLENUM | 17.11 | 0.00 | 01-JAN-00:10 | 6591.93 | 02-JAN-07:20 |
Heating:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 6.78 | 0.00 | 01-JAN-00:10 | 6591.93 | 02-JAN-07:20 |
General:Heating:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 6.78 | 0.00 | 01-JAN-00:10 | 6591.93 | 02-JAN-07:20 |
Cooling:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 10.33 | 0.00 | 01-JAN-00:10 | 3760.07 | 24-JUL-16:00 |
General:Cooling:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 10.33 | 0.00 | 01-JAN-00:10 | 3760.07 | 24-JUL-16:00 |
EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 19.87 | 0.00 | 01-JAN-00:10 | 4226.27 | 24-JUL-16:00 |
Heating:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 4.32 | 0.00 | 01-JAN-00:10 | 3650.35 | 02-JAN-08:40 |
General:Heating:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 4.32 | 0.00 | 01-JAN-00:10 | 3650.35 | 02-JAN-08:40 |
Cooling:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 15.55 | 0.00 | 01-JAN-00:10 | 4226.27 | 24-JUL-16:00 |
General:Cooling:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 15.55 | 0.00 | 01-JAN-00:10 | 4226.27 | 24-JUL-16:00 |
EnergyTransfer:Zone:CORE_MID | 138.73 | 0.00 | 01-JAN-00:10 | 17030.18 | 24-JUL-16:00 |
Heating:EnergyTransfer:Zone:CORE_MID | 0.18 | 0.00 | 01-JAN-00:10 | 9884.15 | 02-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:CORE_MID | 0.18 | 0.00 | 01-JAN-00:10 | 9884.15 | 02-JAN-06:10 |
Cooling:EnergyTransfer:Zone:CORE_MID | 138.55 | 0.00 | 01-JAN-00:10 | 17030.18 | 24-JUL-16:00 |
General:Cooling:EnergyTransfer:Zone:CORE_MID | 138.55 | 0.00 | 01-JAN-00:10 | 17030.18 | 24-JUL-16:00 |
EnergyTransfer:Zone:CORE_TOP | 125.01 | 0.00 | 01-JAN-00:10 | 18192.66 | 24-JUL-15:50 |
Heating:EnergyTransfer:Zone:CORE_TOP | 2.31 | 0.00 | 01-JAN-00:10 | 16985.47 | 26-DEC-06:20 |
General:Heating:EnergyTransfer:Zone:CORE_TOP | 2.31 | 0.00 | 01-JAN-00:10 | 16985.47 | 26-DEC-06:20 |
Cooling:EnergyTransfer:Zone:CORE_TOP | 122.70 | 0.00 | 01-JAN-00:10 | 18192.66 | 24-JUL-15:50 |
General:Cooling:EnergyTransfer:Zone:CORE_TOP | 122.70 | 0.00 | 01-JAN-00:10 | 18192.66 | 24-JUL-15:50 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 27.80 | 0.00 | 01-JAN-00:10 | 6419.92 | 26-DEC-06:20 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 6.45 | 0.00 | 01-JAN-00:10 | 6419.92 | 26-DEC-06:20 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 6.45 | 0.00 | 01-JAN-00:10 | 6419.92 | 26-DEC-06:20 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 21.35 | 0.00 | 01-JAN-00:10 | 5454.33 | 13-JUN-15:50 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 21.35 | 0.00 | 01-JAN-00:10 | 5454.33 | 13-JUN-15:50 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 28.66 | 0.00 | 01-JAN-00:10 | 8124.22 | 13-JUN-08:40 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 3.74 | 0.00 | 01-JAN-00:10 | 5380.46 | 26-DEC-06:20 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 3.74 | 0.00 | 01-JAN-00:10 | 5380.46 | 26-DEC-06:20 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 24.92 | 0.00 | 01-JAN-00:10 | 8124.22 | 13-JUN-08:40 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 24.92 | 0.00 | 01-JAN-00:10 | 8124.22 | 13-JUN-08:40 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 48.31 | 0.00 | 01-JAN-00:10 | 12757.23 | 11-SEP-13:10 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 4.68 | 0.00 | 01-JAN-00:10 | 8132.20 | 26-DEC-06:20 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 4.68 | 0.00 | 01-JAN-00:10 | 8132.20 | 26-DEC-06:20 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 43.64 | 0.00 | 01-JAN-00:10 | 12757.23 | 11-SEP-13:10 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 43.64 | 0.00 | 01-JAN-00:10 | 12757.23 | 11-SEP-13:10 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 29.34 | 0.00 | 01-JAN-00:10 | 9461.46 | 13-JUN-17:00 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 4.07 | 0.00 | 01-JAN-00:10 | 5488.10 | 26-DEC-06:20 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 4.07 | 0.00 | 01-JAN-00:10 | 5488.10 | 26-DEC-06:20 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 25.27 | 0.00 | 01-JAN-00:10 | 9461.46 | 13-JUN-17:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 25.27 | 0.00 | 01-JAN-00:10 | 9461.46 | 13-JUN-17:00 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 22.90 | 0.00 | 01-JAN-00:10 | 4694.89 | 02-JAN-06:10 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 2.39 | 0.00 | 01-JAN-00:10 | 4694.89 | 02-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 2.39 | 0.00 | 01-JAN-00:10 | 4694.89 | 02-JAN-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 20.51 | 0.00 | 01-JAN-00:10 | 3956.43 | 13-JUN-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 20.51 | 0.00 | 01-JAN-00:10 | 3956.43 | 13-JUN-16:00 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 24.57 | 0.00 | 01-JAN-00:10 | 6324.34 | 13-JUN-09:10 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 1.32 | 0.00 | 01-JAN-00:10 | 3581.48 | 02-JAN-06:20 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 1.32 | 0.00 | 01-JAN-00:10 | 3581.48 | 02-JAN-06:20 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 23.25 | 0.00 | 01-JAN-00:10 | 6324.34 | 13-JUN-09:10 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 23.25 | 0.00 | 01-JAN-00:10 | 6324.34 | 13-JUN-09:10 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 41.96 | 0.00 | 01-JAN-00:10 | 10495.35 | 11-SEP-13:40 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 13.41 | 0.00 | 01-JAN-00:10 | 8846.27 | 10-JAN-07:50 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 13.41 | 0.00 | 01-JAN-00:10 | 8846.27 | 10-JAN-07:50 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 28.55 | 0.00 | 01-JAN-00:10 | 10495.35 | 11-SEP-13:40 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 28.55 | 0.00 | 01-JAN-00:10 | 10495.35 | 11-SEP-13:40 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 24.27 | 0.00 | 01-JAN-00:10 | 7139.27 | 13-JUN-17:00 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 1.40 | 0.00 | 01-JAN-00:10 | 3757.61 | 02-JAN-06:20 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 1.40 | 0.00 | 01-JAN-00:10 | 3757.61 | 02-JAN-06:20 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 22.87 | 0.00 | 01-JAN-00:10 | 7139.27 | 13-JUN-17:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 22.87 | 0.00 | 01-JAN-00:10 | 7139.27 | 13-JUN-17:00 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 26.55 | 0.00 | 01-JAN-00:10 | 5016.37 | 13-JUN-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 1.96 | 0.00 | 01-JAN-00:10 | 4873.22 | 02-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 1.96 | 0.00 | 01-JAN-00:10 | 4873.22 | 02-JAN-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 24.59 | 0.00 | 01-JAN-00:10 | 5016.37 | 13-JUN-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 24.59 | 0.00 | 01-JAN-00:10 | 5016.37 | 13-JUN-16:00 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 28.76 | 0.00 | 01-JAN-00:10 | 8203.21 | 13-JUN-08:30 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 1.25 | 0.00 | 01-JAN-00:10 | 3958.53 | 02-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 1.25 | 0.00 | 01-JAN-00:10 | 3958.53 | 02-JAN-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 27.51 | 0.00 | 01-JAN-00:10 | 8203.21 | 13-JUN-08:30 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 27.51 | 0.00 | 01-JAN-00:10 | 8203.21 | 13-JUN-08:30 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 48.89 | 0.00 | 01-JAN-00:10 | 12537.29 | 11-SEP-13:10 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 1.32 | 0.00 | 01-JAN-00:10 | 5437.58 | 02-JAN-06:20 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 1.32 | 0.00 | 01-JAN-00:10 | 5437.58 | 02-JAN-06:20 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 47.57 | 0.00 | 01-JAN-00:10 | 12537.29 | 11-SEP-13:10 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 47.57 | 0.00 | 01-JAN-00:10 | 12537.29 | 11-SEP-13:10 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 28.78 | 0.00 | 01-JAN-00:10 | 9017.55 | 13-JUN-17:00 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 1.28 | 0.00 | 01-JAN-00:10 | 3955.48 | 02-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 1.28 | 0.00 | 01-JAN-00:10 | 3955.48 | 02-JAN-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 27.50 | 0.00 | 01-JAN-00:10 | 9017.55 | 13-JUN-17:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 27.50 | 0.00 | 01-JAN-00:10 | 9017.55 | 13-JUN-17:00 |
PlantLoopHeatingDemand:Facility | 233.18 | 0.00 | 01-JAN-00:10 | 140913.26 | 02-JAN-07:10 |
PlantLoopHeatingDemand:Plant | 53.74 | 0.00 | 01-JAN-00:10 | 6391.26 | 14-FEB-12:10 |
WaterSystems:PlantLoopHeatingDemand | 53.74 | 0.00 | 01-JAN-00:10 | 6391.26 | 14-FEB-12:10 |
General:WaterSystems:PlantLoopHeatingDemand | 53.74 | 0.00 | 01-JAN-00:10 | 6391.26 | 14-FEB-12:10 |
EnergyTransfer:HVAC | 347.70 | 0.00 | 01-JAN-00:10 | 186572.69 | 13-JUN-15:40 |
HeatingCoils:EnergyTransfer | 179.44 | 0.00 | 01-JAN-00:10 | 138812.15 | 02-JAN-07:10 |
PlantLoopHeatingDemand:HVAC | 179.44 | 0.00 | 01-JAN-00:10 | 138812.15 | 02-JAN-07:10 |
HeatingCoils:PlantLoopHeatingDemand | 179.44 | 0.00 | 01-JAN-00:10 | 138812.15 | 02-JAN-07:10 |
CoolingCoils:EnergyTransfer | 168.26 | 0.00 | 01-JAN-00:10 | 186567.05 | 13-JUN-15:40 |
EnergyTransfer:Plant | 231.93 | 0.00 | 01-JAN-00:10 | 139604.87 | 10-JAN-07:10 |
WaterSystems:EnergyTransfer | 53.74 | 0.00 | 01-JAN-00:10 | 6391.26 | 14-FEB-12:10 |
WaterUse:WaterSystems:EnergyTransfer | 53.74 | 0.00 | 01-JAN-00:10 | 6391.26 | 14-FEB-12:10 |
Boilers:EnergyTransfer | 178.19 | 0.00 | 01-JAN-00:10 | 137494.25 | 10-JAN-07:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
CORE_BOTTOM | 0.000 | 0.000 | 0.001 | -209.312 | 0.000 | 0.000 | 32.864 | 71.928 | 250.423 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -145.905 |
CORE_MID | 0.000 | 0.000 | 0.176 | -138.552 | 0.000 | 0.000 | 34.340 | 71.928 | 115.425 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -83.318 |
CORE_TOP | 0.000 | 0.000 | 2.312 | -122.698 | 0.000 | 0.000 | 35.277 | 71.928 | 115.425 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -102.244 |
PERIMETER_TOP_ZN_3 | 0.000 | 0.000 | 6.448 | -21.350 | 0.000 | 0.000 | 7.651 | 9.147 | 24.333 | 13.998 | 0.000 | 0.001 | 0.001 | 0.000 | -32.861 | 0.000 | -2.114 | -5.253 |
PERIMETER_TOP_ZN_2 | 0.000 | 0.000 | 3.736 | -24.922 | 0.000 | 0.000 | 4.797 | 5.682 | 15.404 | 30.501 | 0.000 | 0.001 | 0.001 | 0.000 | -21.198 | 0.000 | -1.435 | -12.566 |
PERIMETER_TOP_ZN_1 | 0.000 | 0.000 | 4.678 | -43.635 | 0.000 | 0.000 | 7.524 | 8.879 | 24.332 | 61.113 | 0.000 | 0.001 | 0.002 | 0.000 | -32.812 | 0.000 | -2.198 | -27.883 |
PERIMETER_TOP_ZN_4 | 0.000 | 0.000 | 4.069 | -25.271 | 0.000 | 0.000 | 4.878 | 5.718 | 15.403 | 29.886 | 0.000 | 0.001 | 0.000 | 0.000 | -22.038 | 0.000 | -1.439 | -11.207 |
PERIMETER_BOT_ZN_3 | 0.000 | 0.000 | 2.392 | -20.512 | 0.000 | 0.000 | 7.607 | 9.112 | 24.333 | 14.220 | 0.000 | 0.001 | 0.000 | 0.000 | -34.343 | 0.000 | -1.178 | -1.631 |
PERIMETER_BOT_ZN_2 | 0.000 | 0.000 | 1.320 | -23.248 | 0.000 | 0.000 | 4.747 | 5.666 | 15.404 | 30.501 | 0.000 | 0.000 | 0.000 | 0.000 | -22.504 | 0.000 | -0.815 | -11.069 |
PERIMETER_BOT_ZN_1 | 0.000 | 0.000 | 13.410 | -28.548 | 0.000 | 0.000 | 7.671 | 8.861 | 24.332 | 61.598 | 0.000 | 0.043 | 0.001 | 0.000 | -34.650 | 0.000 | -36.624 | -16.093 |
PERIMETER_BOT_ZN_4 | 0.000 | 0.000 | 1.397 | -22.869 | 0.000 | 0.000 | 4.806 | 5.700 | 15.403 | 29.964 | 0.000 | 0.000 | 0.001 | 0.000 | -23.370 | 0.000 | -0.817 | -10.215 |
PERIMETER_MID_ZN_3 | 0.000 | 0.000 | 1.959 | -24.589 | 0.000 | 0.000 | 7.522 | 9.146 | 24.333 | 13.579 | 0.000 | 0.001 | 4.946 | 0.000 | -35.029 | 0.000 | -1.868 | -0.000 |
PERIMETER_MID_ZN_2 | 0.000 | 0.000 | 1.250 | -27.512 | 0.000 | 0.000 | 3.519 | 5.682 | 15.404 | 30.219 | 0.000 | 0.001 | 0.002 | 0.000 | -22.468 | 0.000 | -1.260 | -4.834 |
PERIMETER_MID_ZN_1 | 0.000 | 0.000 | 1.320 | -47.573 | 0.000 | 0.000 | 7.398 | 8.879 | 24.332 | 60.653 | 0.000 | 0.001 | 0.002 | 0.000 | -34.858 | 0.000 | -1.937 | -18.215 |
PERIMETER_MID_ZN_4 | 0.000 | 0.000 | 1.277 | -27.502 | 0.000 | 0.000 | 4.802 | 5.718 | 15.403 | 29.624 | 0.000 | 0.000 | 0.000 | 0.000 | -23.431 | 0.000 | -1.269 | -4.622 |
TOPFLOOR_PLENUM | 16.115 | -19.497 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.001 | 6.667 | 0.000 | 0.000 | 0.000 | -3.286 | -0.003 |
MIDFLOOR_PLENUM | 6.776 | -10.332 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.001 | 6.782 | 0.000 | 0.000 | 0.000 | -3.227 | -0.000 |
FIRSTFLOOR_PLENUM | 4.316 | -15.551 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.001 | 13.852 | 0.000 | 0.000 | 0.000 | -2.618 | -0.000 |
Total Facility | 27.207 | -45.380 | 45.744 | -808.093 | 0.000 | 0.000 | 175.402 | 303.975 | 719.689 | 405.857 | 0.000 | 0.052 | 32.258 | 0.000 | -339.561 | 0.000 | -62.085 | -455.060 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
CORE_BOTTOM | 25-JUL-05:12 | 0.00 | 0.00 | 0.00 | -39733.82 | 0.00 | 0.00 | 323.52 | 715.98 | 7410.35 | 0.00 | 0.00 | 0.00 | 31283.98 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 24-JUL-06:02 | 0.00 | 0.00 | 0.00 | -29167.56 | 0.00 | 0.00 | 716.03 | 2148.02 | 3025.92 | 0.00 | 0.00 | 0.00 | 23277.58 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 24-JUL-15:50 | 0.00 | 0.00 | 0.00 | -18192.29 | 0.00 | 0.00 | 3497.12 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 1442.87 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 13-JUN-15:50 | 0.00 | 0.00 | 0.00 | -5454.22 | 0.00 | 0.00 | 737.22 | 647.98 | 1435.25 | 2797.83 | 0.00 | 10.21 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -174.27 |
PERIMETER_TOP_ZN_2 | 23-JUL-09:02 | 0.00 | 0.00 | 0.00 | -13409.62 | 0.00 | 0.00 | 13.97 | 22.79 | 302.86 | 10030.12 | 0.00 | 0.00 | 3094.97 | 0.00 | -0.00 | 0.00 | -55.09 | 0.00 |
PERIMETER_TOP_ZN_1 | 06-AUG-13:22 | 0.00 | 0.00 | 0.00 | -20559.26 | 0.00 | 0.00 | 24.65 | 36.00 | 478.41 | 12228.56 | 0.00 | 0.00 | 7908.62 | 0.00 | -0.00 | 0.00 | -116.99 | 0.00 |
PERIMETER_TOP_ZN_4 | 09-JUL-17:11 | 0.00 | 0.00 | 0.00 | -16527.61 | 0.00 | 0.00 | 0.00 | 22.79 | 244.42 | 11762.40 | 0.00 | 0.00 | 4566.36 | 0.00 | -0.00 | 0.00 | -68.35 | 0.00 |
PERIMETER_BOT_ZN_3 | 13-JUN-16:00 | 0.00 | 0.00 | 0.00 | -3956.42 | 0.00 | 0.00 | 737.23 | 647.98 | 1435.25 | 2810.65 | 0.00 | 5.51 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1680.19 |
PERIMETER_BOT_ZN_2 | 23-JUL-08:52 | 0.00 | 0.00 | 0.00 | -10397.79 | 0.00 | 0.00 | 15.91 | 22.79 | 302.86 | 10451.01 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -30.97 | -363.81 |
PERIMETER_BOT_ZN_1 | 30-APR-13:31 | 0.00 | 0.00 | 0.00 | -16396.98 | 0.00 | 0.00 | 25.33 | 36.00 | 478.41 | 14433.56 | 0.00 | 0.00 | 1447.77 | 0.00 | -0.00 | 0.00 | -24.09 | 0.00 |
PERIMETER_BOT_ZN_4 | 11-JUN-16:32 | 0.00 | 0.00 | 0.00 | -12498.10 | 0.00 | 0.00 | 16.57 | 22.79 | 302.86 | 11334.38 | 0.00 | 0.00 | 875.94 | 0.00 | -0.00 | 0.00 | -54.43 | 0.00 |
PERIMETER_MID_ZN_3 | 13-JUN-16:00 | 0.00 | 0.00 | 0.00 | -5016.16 | 0.00 | 0.00 | 737.23 | 647.98 | 1435.25 | 2771.79 | 0.00 | 8.54 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -584.62 |
PERIMETER_MID_ZN_2 | 23-JUL-08:42 | 0.00 | 0.00 | 0.00 | -13575.30 | 0.00 | 0.00 | 13.83 | 22.79 | 302.86 | 10641.55 | 0.00 | 0.00 | 2643.77 | 0.00 | -0.00 | 0.00 | -49.51 | 0.00 |
PERIMETER_MID_ZN_1 | 24-SEP-13:12 | 0.00 | 0.00 | 0.00 | -19619.04 | 0.00 | 0.00 | 24.25 | 36.00 | 478.41 | 14656.61 | 0.00 | 0.00 | 4508.32 | 0.00 | -0.00 | 0.00 | -84.55 | 0.00 |
PERIMETER_MID_ZN_4 | 21-MAY-17:02 | 0.00 | 0.00 | 0.00 | -14802.87 | 0.00 | 0.00 | 0.00 | 22.79 | 244.42 | 10876.98 | 0.00 | 0.00 | 3715.29 | 0.00 | -0.00 | 0.00 | -56.61 | 0.00 |
TOPFLOOR_PLENUM | 13-JUN-14:30 | 0.00 | -8958.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8960.74 | 0.00 | -0.00 | 0.00 | -1.79 | 0.00 |
MIDFLOOR_PLENUM | 24-JUL-16:00 | 0.00 | -3760.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3784.73 | 0.00 | -0.00 | 0.00 | -24.72 | 0.00 |
FIRSTFLOOR_PLENUM | 24-JUL-16:00 | 0.00 | -4226.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4245.31 | 0.00 | -0.00 | 0.00 | -19.11 | 0.00 |
Total Facility | 13-JUN-15:40 | 0.00 | -16401.56 | 0.00 | -128429.85 | 0.00 | 0.00 | 17714.92 | 25681.07 | 41670.51 | 63574.96 | 0.00 | 346.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -4156.44 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
CORE_BOTTOM | 02-JAN-07:01 | 0.00 | 0.00 | 2396.75 | 0.00 | 0.00 | 0.00 | 909.79 | 2148.02 | 10194.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -15649.41 |
CORE_MID | 02-JAN-06:02 | 0.00 | 0.00 | 10811.48 | 0.00 | 0.00 | 0.00 | 498.57 | 211.73 | 3025.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -14547.70 |
CORE_TOP | 02-JAN-05:01 | 0.00 | 0.00 | 19518.75 | 0.00 | 0.00 | 0.00 | 0.00 | 211.73 | 2442.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -22172.53 |
PERIMETER_TOP_ZN_3 | 09-JAN-05:01 | 0.00 | 0.00 | 7133.93 | 0.00 | 0.00 | 0.00 | 0.00 | 44.64 | 514.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2072.68 | 0.00 | 0.00 | -5620.69 |
PERIMETER_TOP_ZN_2 | 09-JAN-05:01 | 0.00 | 0.00 | 6631.58 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 325.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1376.40 | 0.00 | 0.00 | -5609.33 |
PERIMETER_TOP_ZN_1 | 02-JAN-05:01 | 0.00 | 0.00 | 9866.93 | 0.00 | 0.00 | 0.00 | 0.00 | 44.64 | 514.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1692.54 | 0.00 | 0.00 | -8733.82 |
PERIMETER_TOP_ZN_4 | 02-JAN-05:01 | 0.00 | 0.00 | 6835.87 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 325.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1107.20 | 0.00 | 0.00 | -6082.81 |
PERIMETER_BOT_ZN_3 | 02-JAN-05:01 | 0.00 | 0.00 | 5349.03 | 0.00 | 0.00 | 0.00 | 0.00 | 44.64 | 514.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1786.56 | 0.00 | 0.00 | -4121.91 |
PERIMETER_BOT_ZN_2 | 02-JAN-05:01 | 0.00 | 0.00 | 4739.38 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 325.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1232.67 | 0.00 | 0.00 | -3860.85 |
PERIMETER_BOT_ZN_1 | 10-JAN-07:50 | 0.00 | 0.00 | 8845.10 | 0.00 | 0.00 | 0.00 | 235.15 | 452.82 | 637.88 | 0.00 | 0.00 | 0.00 | 9958.85 | 0.00 | -2697.27 | 0.00 | -17432.53 | 0.00 |
PERIMETER_BOT_ZN_4 | 02-JAN-05:01 | 0.00 | 0.00 | 4985.46 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 325.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1218.36 | 0.00 | 0.00 | -4121.25 |
PERIMETER_MID_ZN_3 | 02-JAN-05:01 | 0.00 | 0.00 | 5671.47 | 0.00 | 0.00 | 0.00 | 0.00 | 44.64 | 514.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1772.96 | 0.00 | 0.00 | -4457.95 |
PERIMETER_MID_ZN_2 | 02-JAN-05:01 | 0.00 | 0.00 | 5272.52 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 325.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1191.08 | 0.00 | 0.00 | -4435.60 |
PERIMETER_MID_ZN_1 | 02-JAN-05:01 | 0.00 | 0.00 | 7390.25 | 0.00 | 0.00 | 0.00 | 0.00 | 44.64 | 514.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1856.49 | 0.00 | 0.00 | -6093.20 |
PERIMETER_MID_ZN_4 | 02-JAN-05:01 | 0.00 | 0.00 | 5314.37 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 325.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1189.40 | 0.00 | 0.00 | -4479.12 |
TOPFLOOR_PLENUM | 04-DEC-06:19 | 11263.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -66.60 | -11196.48 |
MIDFLOOR_PLENUM | 02-JAN-07:12 | 6661.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -6661.23 |
FIRSTFLOOR_PLENUM | 20-APR-05:03 | 4350.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -4350.38 |
Total Facility | 02-JAN-06:02 | 5950.83 | 4178.32 | 94153.31 | -4178.32 | 0.00 | 0.00 | 2491.26 | 1072.56 | 19712.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -18704.33 | 0.00 | -1968.24 | -102707.73 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PACU_VAV_BOT | 5.5083 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 4.7867 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_MID | 5.4172 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 4.4741 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_TOP | 5.6162 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 4.9912 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PACU_VAV_BOT | 2.7542 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.4012 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_MID | 2.7086 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.4604 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_TOP | 2.8081 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.5124 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
CORE_BOTTOM | PACU_VAV_BOT | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORE_MID | PACU_VAV_MID | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORE_TOP | PACU_VAV_TOP | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PACU_VAV_BOT | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 | |
PACU_VAV_MID | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 | |
PACU_VAV_TOP | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
CORE_BOTTOM | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.7082 | 2.7082 | 0.7718 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_MID | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.1775 | 2.1775 | 0.7578 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_TOP | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.1930 | 2.1930 | 0.7807 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5885 | 0.5885 | 0.1648 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7868 | 0.7868 | 0.1574 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.1787 | 1.1787 | 0.2357 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.8693 | 0.8693 | 0.1739 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4683 | 0.4683 | 0.1630 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6445 | 0.6445 | 0.1289 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.9637 | 0.9637 | 0.1927 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7236 | 0.7236 | 0.1447 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5258 | 0.5258 | 0.1598 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7924 | 0.7924 | 0.1585 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.1053 | 1.1053 | 0.2211 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.8162 | 0.8162 | 0.1632 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PACU_VAV_BOT | 5.5083 | 4.7867 | 5.5083 | 1.4012 | 0.0000 | 1.0000 |
PACU_VAV_MID | 5.4172 | 4.4741 | 5.4172 | 1.4604 | 0.0000 | 1.0000 |
PACU_VAV_TOP | 5.6162 | 4.9912 | 5.6162 | 1.5124 | 0.0000 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
CORE_BOTTOM | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.3541 | 1.3541 | 0.7718 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_MID | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.0888 | 1.0888 | 0.7578 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_TOP | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.0965 | 1.0965 | 0.7807 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2942 | 0.2942 | 0.1648 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3934 | 0.3934 | 0.1574 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5894 | 0.5894 | 0.2357 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4346 | 0.4346 | 0.1739 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2342 | 0.2342 | 0.1630 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3222 | 0.3222 | 0.1289 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4819 | 0.4819 | 0.1927 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3618 | 0.3618 | 0.1447 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2629 | 0.2629 | 0.1598 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3962 | 0.3962 | 0.1585 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5527 | 0.5527 | 0.2211 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4081 | 0.4081 | 0.1632 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PACU_VAV_BOT | 2.7542 | 1.4012 | 1.4012 | 1.4012 | 0.0000 | 1.0000 |
PACU_VAV_MID | 2.7086 | 1.4604 | 1.4604 | 1.4604 | 0.0000 | 1.0000 |
PACU_VAV_TOP | 2.8081 | 1.5124 | 1.5124 | 1.5124 | 0.0000 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** William R Fairchild WA USA TMY3 WMO#=727885 |
Total gross floor area [m2] | 4982.19 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
CORE_BOTTOM | 983.54 | 983.54 | 0.00 | 113.98 |
CORE_MID | 983.54 | 983.54 | 0.00 | 113.98 |
CORE_TOP | 983.54 | 983.54 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_2 | 131.26 | 131.26 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_2 | 131.26 | 131.26 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
PERIMETER_MID_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_MID_ZN_2 | 131.26 | 131.26 | 0.00 | 96.54 |
PERIMETER_MID_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_MID_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
TOPFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
Totals | 4982.19 | 4982.19 | 0.00 |
Data | |
Number of hours heating loads not met | 378.17 |
Number of hours cooling loads not met | 72.17 |
Number of hours not met | 450.33 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heating -- Boiler | 0.00 | 0.00 | 263.87 | 174236.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heating -- Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- General | 38.31 | 41647.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 303.97 | 32642.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 51.76 | 5686.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ElevatorLift | 134.36 | 7125.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ElevatorLightsFan | 0.64 | 86.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 584.69 | 34487.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Transformer | 26.90 | 1410.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 75.99 | 22047.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- General | 1.29 | 552.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 56.54 | 6667.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 719.69 | 1274.46 |
Natural Gas | 0.00 | 263.87 |
Additional | 0.00 | 0.00 |
Total | 719.69 | 1538.32 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 61.01 |
Space Heating | 0.00 |
Space Cooling | 7.69 |
Fans (All) | 15.25 |
Service Water Heating | 11.35 |
Receptacle Equipment | 144.45 |
Miscellaneous (All) | 255.80 |
Subtotal | 255.80 |
Natural Gas [MJ/m2] | |
Space Heating | 52.96 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 52.96 |
Subtotal | 52.96 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 19.76 |
Space Heating | 17.15 |
Space Cooling | 2.49 |
Fans (All) | 4.94 |
Service Water Heating | 3.68 |
Receptacle Equipment | 46.78 |
Miscellaneous | 5.20 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
ELEVATOR_RUNNING_SCH | 145. | 3744. |
ELEVATOR_STANDBY_SCH | 8276. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4472. | 4472. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 6752. | 8760. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6828. | 8760. |
ALWAYS_OFF | 0. | 0. |
LTG_SCH_OFFICE | 2460. | 8760. |
BLDG_EQUIP_SCH | 4095. | 8760. |
BLDG_OCC_SCH | 2528. | 5992. |
BLDG_OCC_SCH_W_SB | 1878. | 5056. |
BLDG_OCC_SCH_WO_SB | 2545. | 5992. |
ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
ELEV_LIGHT_FAN_SCH_ADD_DF | 1470. | 4212. |
BLDG_SWH_SCH | 1441. | 5992. |
WORK_EFF_SCH | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4472. | 4472. |
MINOA_SCHED | 8760. | 8760. |
CORE_BOTTOM SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_BOTTOM SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
CORE_MID SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_MID SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
CORE_TOP SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_TOP SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
INFIL_SCH_PNNL | 5172. | 8760. |
INFIL_DOOR_OPENING_SCH | 1121. | 3380. |
PERIMETER_MID_ZN_2_OA_MULT | 7824. | 7824. |
PERIMETER_MID_ZN_2_MDP_SCH | 1574. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_SCH_YES_OPTIMUM | CORE_BOTTOM DUAL SP CONTROL | January | 21.00 | 365 | 15.60 | 365 |
CLGSETP_SCH_YES_OPTIMUM | CORE_BOTTOM DUAL SP CONTROL | July | 24.00 | 365 | 26.70 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Heat Index HoursSafe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
CORE_BOTTOM | 8753.00 | 7.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 8746.00 | 14.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 8744.17 | 15.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 8742.17 | 17.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 8745.33 | 14.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 8748.50 | 11.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 8747.83 | 12.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 8743.50 | 16.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 8743.33 | 16.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 8739.67 | 20.33 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 8750.17 | 9.83 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 8739.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 8760.00 | 20.33 | 0.00 | 0.00 | 0.00 |
Average | 8751.31 | 8.69 | 0.00 | 0.00 | 0.00 |
Sum | 157523.67 | 156.33 | 0.00 | 0.00 | 0.00 |
Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
CORE_BOTTOM | 128304.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 128304.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 128304.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 10134.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 128304.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Average | 34143.33 | 0.00 | 0.00 | 0.00 | 0.00 |
Sum | 614580.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
CORE_BOTTOM | 8665.17 | 94.83 | 0.00 | 0.00 | 0.00 |
CORE_MID | 8752.83 | 7.17 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 8752.00 | 8.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 8750.67 | 9.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 8743.00 | 17.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 8750.00 | 10.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 8752.00 | 8.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 8747.17 | 12.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 8749.50 | 10.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 8750.33 | 9.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 8742.00 | 18.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 8752.33 | 7.67 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 8665.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 8760.00 | 94.83 | 0.00 | 0.00 | 0.00 |
Average | 8748.17 | 11.83 | 0.00 | 0.00 | 0.00 |
Sum | 157467.00 | 213.00 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
CORE_BOTTOM | 128249.33 | 54.67 | 0.00 | 0.00 | 0.00 |
CORE_MID | 128301.67 | 2.33 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 128304.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 10134.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 128304.00 | 54.67 | 0.00 | 0.00 | 0.00 |
Average | 34140.17 | 3.17 | 0.00 | 0.00 | 0.00 |
Sum | 614523.00 | 57.00 | 0.00 | 0.00 | 0.00 |
SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
None |
SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
CO2 Level HoursSafe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2024-07-03 12:20:09
Illuminance Level HoursA Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
CORE_BOTTOM | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 0.00 | 8760.00 | 0.00 |
Average | 0.00 | 0.00 | 5840.00 | 0.00 |
Sum | 0.00 | 0.00 | 105120.00 | 0.00 |
A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
CORE_BOTTOM | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_MID_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_MID_ZN_2 | 0.00 | 0.00 | 10134.00 | 0.00 |
PERIMETER_MID_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_MID_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 0.00 | 24909.00 | 0.00 |
Average | 0.00 | 0.00 | 12759.33 | 0.00 |
Sum | 0.00 | 0.00 | 229668.00 | 0.00 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5C
For: Environment
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 4.180 |
February | 4.245 |
March | 5.898 |
April | 8.962 |
May | 9.987 |
June | 13.308 |
July | 15.016 |
August | 15.650 |
September | 13.434 |
October | 9.327 |
November | 6.665 |
December | 4.103 |
Annual Sum or Average | 9.257 |
Minimum of Months | 4.103 |
Maximum of Months | 15.650 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 4.180 |
February | 4.245 |
March | 5.898 |
April | 8.962 |
May | 9.987 |
June | 13.308 |
July | 15.016 |
August | 15.650 |
September | 13.434 |
October | 9.327 |
November | 6.665 |
December | 4.103 |
Annual Sum or Average | 9.257 |
Minimum of Months | 4.103 |
Maximum of Months | 15.650 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
For: Environment
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 4.180 |
February | 4.245 |
March | 5.898 |
April | 8.962 |
May | 9.987 |
June | 13.308 |
July | 15.016 |
August | 15.650 |
September | 13.434 |
October | 9.327 |
November | 6.665 |
December | 4.103 |
Annual Sum or Average | 9.257 |
Minimum of Months | 4.103 |
Maximum of Months | 15.650 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2016
For: Environment
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 4.180 |
February | 4.245 |
March | 5.898 |
April | 8.962 |
May | 9.987 |
June | 13.308 |
July | 15.016 |
August | 15.650 |
September | 13.434 |
October | 9.327 |
November | 6.665 |
December | 4.103 |
Annual Sum or Average | 9.257 |
Minimum of Months | 4.103 |
Maximum of Months | 15.650 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICEMEDIUM
For: Environment
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 4.180 |
February | 4.245 |
March | 5.898 |
April | 8.962 |
May | 9.987 |
June | 13.308 |
July | 15.016 |
August | 15.650 |
September | 13.434 |
October | 9.327 |
November | 6.665 |
December | 4.103 |
Annual Sum or Average | 9.257 |
Minimum of Months | 4.103 |
Maximum of Months | 15.650 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_WA_PORTANGELES
For: Environment
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 4.180 |
February | 4.245 |
March | 5.898 |
April | 8.962 |
May | 9.987 |
June | 13.308 |
July | 15.016 |
August | 15.650 |
September | 13.434 |
October | 9.327 |
November | 6.665 |
December | 4.103 |
Annual Sum or Average | 9.257 |
Minimum of Months | 4.103 |
Maximum of Months | 15.650 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 4.180 |
February | 4.245 |
March | 5.898 |
April | 8.962 |
May | 9.987 |
June | 13.308 |
July | 15.016 |
August | 15.650 |
September | 13.434 |
October | 9.327 |
November | 6.665 |
December | 4.103 |
Annual Sum or Average | 9.257 |
Minimum of Months | 4.103 |
Maximum of Months | 15.650 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PERFORMANCEPATHPROPOSED
For: Environment
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 4.180 |
February | 4.245 |
March | 5.898 |
April | 8.962 |
May | 9.987 |
June | 13.308 |
July | 15.016 |
August | 15.650 |
September | 13.434 |
October | 9.327 |
November | 6.665 |
December | 4.103 |
Annual Sum or Average | 9.257 |
Minimum of Months | 4.103 |
Maximum of Months | 15.650 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 4.180 |
February | 4.245 |
March | 5.898 |
April | 8.962 |
May | 9.987 |
June | 13.308 |
July | 15.016 |
August | 15.650 |
September | 13.434 |
October | 9.327 |
November | 6.665 |
December | 4.103 |
Annual Sum or Average | 9.257 |
Minimum of Months | 4.103 |
Maximum of Months | 15.650 |
Report: ZoneCoolingSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.110311E+11 | 14068.31 | 20-JAN-16:40 | 5.67 | 5.02 | 0.191962E+10 | 2606.66 | 23-JAN-10:20 | 9.67 | 8.91 |
February | 0.109594E+11 | 14312.18 | 10-FEB-17:00 | 6.00 | 4.60 | 0.178534E+10 | 2606.65 | 22-FEB-10:09 | 8.33 | 8.16 |
March | 0.134670E+11 | 14668.57 | 31-MAR-16:00 | 9.00 | 4.96 | 0.213697E+10 | 2606.65 | 28-MAR-13:09 | 9.00 | 4.96 |
April | 0.181412E+11 | 32933.75 | 20-APR-05:03 | 1.17 | -0.2 | 0.191548E+10 | 2606.74 | 14-APR-13:00 | 1.17 | -0.2 |
May | 0.210781E+11 | 36998.64 | 01-MAY-06:02 | 6.17 | 4.70 | 0.207732E+10 | 2606.64 | 05-MAY-13:00 | 8.00 | 6.98 |
June | 0.235490E+11 | 39561.15 | 27-JUN-05:12 | 14.33 | 14.33 | 0.207195E+10 | 2606.75 | 08-JUN-13:09 | 14.33 | 14.33 |
July | 0.236911E+11 | 39737.31 | 25-JUL-05:12 | 13.00 | 13.00 | 0.192627E+10 | 2606.68 | 03-JUL-09:09 | 13.00 | 13.00 |
August | 0.256499E+11 | 37964.76 | 07-AUG-06:02 | 11.67 | 10.35 | 0.216066E+10 | 2606.68 | 08-AUG-13:09 | 17.83 | 16.43 |
September | 0.219480E+11 | 37154.06 | 13-SEP-06:02 | 11.17 | 10.64 | 0.191813E+10 | 2606.77 | 19-SEP-13:50 | 14.33 | 13.96 |
October | 0.164691E+11 | 36039.28 | 02-OCT-06:02 | 10.00 | 7.49 | 0.198836E+10 | 2606.71 | 17-OCT-09:09 | 12.33 | 11.88 |
November | 0.126099E+11 | 15480.35 | 03-NOV-16:00 | 8.00 | 4.84 | 0.195663E+10 | 2606.64 | 10-NOV-10:09 | 11.00 | 9.41 |
December | 0.107180E+11 | 12398.27 | 22-DEC-17:00 | 5.00 | 4.08 | 0.187328E+10 | 2606.64 | 07-DEC-10:20 | 5.00 | 4.08 |
Annual Sum or Average | 0.209312E+12 | 0.237300E+11 | ||||||||
Minimum of Months | 0.107180E+11 | 12398.27 | 1.17 | -0.2 | 0.178534E+10 | 2606.64 | 1.17 | -0.2 | ||
Maximum of Months | 0.256499E+11 | 39737.31 | 14.33 | 14.33 | 0.216066E+10 | 2606.77 | 17.83 | 16.43 |
Report: ZoneCoolingSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 22175252.58 | 676.94 | 19-JAN-17:10 | 5.83 | 5.75 | 0.00 | 0.00 | 01-JAN-00:10 | 5.83 | 5.75 |
February | 67708532.35 | 1051.29 | 04-FEB-15:50 | 7.33 | 5.73 | 0.00 | 0.00 | 01-FEB-00:10 | 7.33 | 5.73 |
March | 0.184333E+09 | 2033.93 | 25-MAR-12:50 | 13.67 | 10.83 | 0.00 | 0.00 | 01-MAR-00:10 | 13.67 | 10.83 |
April | 0.202116E+10 | 7452.19 | 28-APR-15:00 | 20.10 | 13.70 | 0.00 | 0.00 | 01-APR-00:10 | 20.10 | 13.70 |
May | 0.241754E+10 | 8010.25 | 22-MAY-14:50 | 23.83 | 16.03 | 0.00 | 0.00 | 01-MAY-00:10 | 23.83 | 16.03 |
June | 0.354577E+10 | 8958.91 | 13-JUN-14:30 | 25.55 | 17.64 | 0.00 | 0.00 | 01-JUN-00:10 | 25.55 | 17.64 |
July | 0.415052E+10 | 8953.36 | 21-JUL-14:50 | 27.00 | 15.89 | 0.00 | 0.00 | 01-JUL-00:10 | 27.00 | 15.89 |
August | 0.398066E+10 | 8103.16 | 14-AUG-15:00 | 25.00 | 16.02 | 0.00 | 0.00 | 01-AUG-00:10 | 25.00 | 16.02 |
September | 0.249387E+10 | 6853.64 | 13-SEP-14:20 | 23.00 | 16.22 | 0.00 | 0.00 | 01-SEP-00:10 | 23.00 | 16.22 |
October | 0.583446E+09 | 3299.64 | 03-OCT-14:30 | 14.00 | 9.18 | 0.00 | 0.00 | 01-OCT-00:10 | 14.00 | 9.18 |
November | 30098227.00 | 747.03 | 11-NOV-13:50 | 9.00 | 7.08 | 0.00 | 0.00 | 01-NOV-00:10 | 9.00 | 7.08 |
December | 54937.09 | 103.01 | 06-DEC-13:03 | 7.00 | 5.20 | 0.00 | 0.00 | 01-DEC-00:10 | 7.00 | 5.20 |
Annual Sum or Average | 0.194973E+11 | 0.00 | ||||||||
Minimum of Months | 54937.09 | 103.01 | 5.83 | 5.20 | 0.00 | 0.00 | 5.83 | 5.20 | ||
Maximum of Months | 0.415052E+10 | 8958.91 | 27.00 | 17.64 | 0.00 | 0.00 | 27.00 | 17.64 |
Report: ZoneCoolingSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 54147513.94 | 1778.65 | 07-JAN-06:11 | 3.00 | 2.13 | 0.00 | 0.00 | 01-JAN-00:10 | 3.00 | 2.13 |
February | 71872190.27 | 1753.80 | 10-FEB-07:02 | 4.83 | 4.43 | 0.00 | 0.00 | 01-FEB-00:10 | 4.83 | 4.43 |
March | 0.164631E+09 | 2308.97 | 24-MAR-06:02 | 4.00 | 3.12 | 0.00 | 0.00 | 01-MAR-00:10 | 4.00 | 3.12 |
April | 0.761684E+09 | 2512.61 | 28-APR-16:00 | 20.00 | 12.32 | 0.00 | 0.00 | 01-APR-00:10 | 20.00 | 12.32 |
May | 0.108657E+10 | 2810.89 | 23-MAY-16:00 | 18.00 | 14.38 | 0.00 | 0.00 | 01-MAY-00:10 | 18.00 | 14.38 |
June | 0.184929E+10 | 3617.69 | 13-JUN-15:30 | 26.25 | 17.77 | 0.00 | 0.00 | 01-JUN-00:10 | 26.25 | 17.77 |
July | 0.221472E+10 | 3760.07 | 24-JUL-16:00 | 20.00 | 16.18 | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 | 16.18 |
August | 0.222185E+10 | 3191.19 | 14-AUG-16:00 | 26.00 | 15.86 | 0.00 | 0.00 | 01-AUG-00:10 | 26.00 | 15.86 |
September | 0.141345E+10 | 2976.19 | 13-SEP-16:00 | 23.00 | 16.22 | 0.00 | 0.00 | 01-SEP-00:10 | 23.00 | 16.22 |
October | 0.373989E+09 | 2187.13 | 19-OCT-06:03 | 5.33 | 4.70 | 0.00 | 0.00 | 01-OCT-00:10 | 5.33 | 4.70 |
November | 0.105809E+09 | 2035.71 | 01-NOV-06:03 | 5.00 | 4.51 | 0.00 | 0.00 | 01-NOV-00:10 | 5.00 | 4.51 |
December | 14017872.06 | 1755.86 | 23-DEC-06:11 | 3.00 | 2.55 | 0.00 | 0.00 | 01-DEC-00:10 | 3.00 | 2.55 |
Annual Sum or Average | 0.103320E+11 | 0.00 | ||||||||
Minimum of Months | 14017872.06 | 1753.80 | 3.00 | 2.13 | 0.00 | 0.00 | 3.00 | 2.13 | ||
Maximum of Months | 0.222185E+10 | 3760.07 | 26.25 | 17.77 | 0.00 | 0.00 | 26.25 | 17.77 |
Report: ZoneCoolingSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.174897E+09 | 2377.75 | 26-JAN-07:02 | 4.83 | 4.35 | 0.00 | 0.00 | 01-JAN-00:10 | 4.83 | 4.35 |
February | 0.211576E+09 | 2576.98 | 09-FEB-06:11 | 2.33 | 2.19 | 0.00 | 0.00 | 01-FEB-00:10 | 2.33 | 2.19 |
March | 0.348522E+09 | 2761.13 | 24-MAR-06:02 | 4.00 | 3.12 | 0.00 | 0.00 | 01-MAR-00:10 | 4.00 | 3.12 |
April | 0.130507E+10 | 2980.67 | 28-APR-16:00 | 20.00 | 12.32 | 0.00 | 0.00 | 01-APR-00:10 | 20.00 | 12.32 |
May | 0.177927E+10 | 3824.72 | 01-MAY-06:08 | 6.17 | 4.70 | 0.00 | 0.00 | 01-MAY-00:10 | 6.17 | 4.70 |
June | 0.253830E+10 | 4079.24 | 13-JUN-16:00 | 26.50 | 17.70 | 0.00 | 0.00 | 01-JUN-00:10 | 26.50 | 17.70 |
July | 0.286720E+10 | 4226.27 | 24-JUL-16:00 | 20.00 | 16.18 | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 | 16.18 |
August | 0.299159E+10 | 3861.82 | 14-AUG-16:00 | 26.00 | 15.86 | 0.00 | 0.00 | 01-AUG-00:10 | 26.00 | 15.86 |
September | 0.220419E+10 | 3671.81 | 13-SEP-16:00 | 23.00 | 16.22 | 0.00 | 0.00 | 01-SEP-00:10 | 23.00 | 16.22 |
October | 0.759003E+09 | 2940.21 | 04-OCT-06:06 | 3.17 | 3.17 | 0.00 | 0.00 | 01-OCT-00:10 | 3.17 | 3.17 |
November | 0.258116E+09 | 2648.14 | 01-NOV-06:03 | 5.00 | 4.51 | 0.00 | 0.00 | 01-NOV-00:10 | 5.00 | 4.51 |
December | 0.113022E+09 | 2290.27 | 08-DEC-06:11 | 1.67 | 1.24 | 0.00 | 0.00 | 01-DEC-00:10 | 1.67 | 1.24 |
Annual Sum or Average | 0.155508E+11 | 0.00 | ||||||||
Minimum of Months | 0.113022E+09 | 2290.27 | 1.67 | 1.24 | 0.00 | 0.00 | 1.67 | 1.24 | ||
Maximum of Months | 0.299159E+10 | 4226.27 | 26.50 | 17.70 | 0.00 | 0.00 | 26.50 | 17.70 |
Report: ZoneCoolingSummaryMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.756452E+10 | 7443.56 | 20-JAN-17:00 | 5.00 | 4.51 | 0.166884E+10 | 2500.90 | 20-JAN-14:00 | 5.00 | 4.51 |
February | 0.758303E+10 | 7424.40 | 24-FEB-17:00 | 6.00 | 4.60 | 0.155877E+10 | 2467.63 | 24-FEB-14:00 | 6.00 | 4.60 |
March | 0.922286E+10 | 7525.61 | 31-MAR-16:00 | 9.00 | 4.96 | 0.189880E+10 | 2506.29 | 31-MAR-13:00 | 9.00 | 4.96 |
April | 0.115121E+11 | 14447.29 | 28-APR-16:00 | 20.00 | 12.32 | 0.186839E+10 | 2606.70 | 14-APR-13:00 | 20.00 | 12.32 |
May | 0.137069E+11 | 15267.01 | 23-MAY-16:00 | 18.00 | 14.38 | 0.204798E+10 | 2606.62 | 22-MAY-13:00 | 18.00 | 14.38 |
June | 0.157441E+11 | 16376.02 | 26-JUN-16:00 | 22.00 | 17.42 | 0.205803E+10 | 2606.68 | 08-JUN-13:09 | 22.00 | 17.42 |
July | 0.161627E+11 | 29168.52 | 24-JUL-06:02 | 13.17 | 13.07 | 0.191349E+10 | 2606.65 | 03-JUL-09:09 | 13.17 | 13.07 |
August | 0.171867E+11 | 15789.41 | 18-AUG-16:00 | 21.00 | 16.54 | 0.214949E+10 | 2606.67 | 15-AUG-09:09 | 21.00 | 16.54 |
September | 0.142285E+11 | 15523.09 | 13-SEP-16:00 | 23.00 | 16.22 | 0.189858E+10 | 2606.72 | 19-SEP-13:50 | 14.33 | 13.96 |
October | 0.100893E+11 | 12744.32 | 03-OCT-16:00 | 14.00 | 8.96 | 0.186973E+10 | 2606.64 | 02-OCT-09:20 | 14.00 | 8.96 |
November | 0.827408E+10 | 7621.15 | 10-NOV-17:00 | 7.00 | 6.47 | 0.173165E+10 | 2543.64 | 10-NOV-14:00 | 7.00 | 6.47 |
December | 0.727686E+10 | 6982.66 | 21-DEC-15:10 | 7.83 | 6.90 | 0.159048E+10 | 2408.56 | 21-DEC-14:00 | 7.83 | 6.90 |
Annual Sum or Average | 0.138552E+12 | 0.222542E+11 | ||||||||
Minimum of Months | 0.727686E+10 | 6982.66 | 5.00 | 4.51 | 0.155877E+10 | 2408.56 | 5.00 | 4.51 | ||
Maximum of Months | 0.171867E+11 | 29168.52 | 23.00 | 17.42 | 0.214949E+10 | 2606.72 | 22.00 | 17.42 |
Report: ZoneCoolingSummaryMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.564177E+10 | 7205.49 | 19-JAN-16:40 | 6.67 | 6.49 | 0.155905E+10 | 2384.32 | 20-JAN-14:00 | 8.00 | 6.49 |
February | 0.597428E+10 | 7222.50 | 09-FEB-17:00 | 6.00 | 4.60 | 0.144896E+10 | 2359.69 | 24-FEB-14:00 | 6.00 | 4.60 |
March | 0.779899E+10 | 7437.17 | 31-MAR-16:00 | 9.00 | 4.96 | 0.177029E+10 | 2408.45 | 31-MAR-15:00 | 9.00 | 4.96 |
April | 0.107142E+11 | 15486.41 | 28-APR-16:00 | 20.00 | 12.32 | 0.179564E+10 | 2606.69 | 14-APR-13:00 | 20.00 | 12.32 |
May | 0.127126E+11 | 16518.77 | 23-MAY-15:50 | 18.00 | 14.38 | 0.199439E+10 | 2606.63 | 22-MAY-13:00 | 18.00 | 14.38 |
June | 0.150512E+11 | 18016.11 | 13-JUN-16:00 | 26.50 | 17.70 | 0.203883E+10 | 2606.67 | 09-JUN-13:00 | 26.50 | 17.70 |
July | 0.155695E+11 | 18192.66 | 24-JUL-15:50 | 19.83 | 16.14 | 0.189902E+10 | 2606.63 | 21-JUL-13:09 | 19.83 | 16.14 |
August | 0.162360E+11 | 16786.14 | 18-AUG-15:50 | 20.67 | 16.45 | 0.213121E+10 | 2606.68 | 15-AUG-09:09 | 20.67 | 16.45 |
September | 0.127797E+11 | 16078.89 | 13-SEP-16:00 | 23.00 | 16.22 | 0.186089E+10 | 2606.71 | 19-SEP-13:50 | 14.33 | 13.96 |
October | 0.879773E+10 | 11624.27 | 03-OCT-16:00 | 14.00 | 8.96 | 0.174037E+10 | 2606.56 | 02-OCT-13:00 | 14.00 | 8.96 |
November | 0.663064E+10 | 7458.98 | 10-NOV-16:30 | 9.00 | 7.52 | 0.159623E+10 | 2447.78 | 10-NOV-14:00 | 9.00 | 7.52 |
December | 0.479152E+10 | 6736.36 | 21-DEC-15:30 | 7.50 | 6.73 | 0.148257E+10 | 2292.78 | 21-DEC-14:00 | 7.50 | 6.73 |
Annual Sum or Average | 0.122698E+12 | 0.213175E+11 | ||||||||
Minimum of Months | 0.479152E+10 | 6736.36 | 6.00 | 4.60 | 0.144896E+10 | 2292.78 | 6.00 | 4.60 | ||
Maximum of Months | 0.162360E+11 | 18192.66 | 26.50 | 17.70 | 0.213121E+10 | 2606.71 | 26.50 | 17.70 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.319428E+09 | 1262.03 | 19-JAN-15:40 | 8.33 | 7.46 | 0.308569E+09 | 443.18 | 19-JAN-14:00 | 8.33 | 7.46 |
February | 0.452692E+09 | 1240.12 | 09-FEB-16:00 | 8.00 | 5.66 | 0.281528E+09 | 438.79 | 03-FEB-14:00 | 8.00 | 5.66 |
March | 0.859255E+09 | 1425.85 | 30-MAR-15:50 | 12.00 | 5.94 | 0.346559E+09 | 481.79 | 30-MAR-13:00 | 12.00 | 5.94 |
April | 0.196295E+10 | 3804.61 | 28-APR-15:30 | 20.05 | 13.01 | 0.358433E+09 | 549.50 | 14-APR-13:00 | 20.05 | 13.01 |
May | 0.255097E+10 | 4318.32 | 22-MAY-15:20 | 23.67 | 15.81 | 0.403612E+09 | 549.50 | 22-MAY-13:00 | 23.67 | 15.81 |
June | 0.345918E+10 | 5454.33 | 13-JUN-15:50 | 26.42 | 17.72 | 0.424345E+09 | 549.50 | 09-JUN-13:00 | 26.42 | 17.72 |
July | 0.372198E+10 | 5218.98 | 10-JUL-15:00 | 23.00 | 16.69 | 0.396971E+09 | 549.50 | 21-JUL-13:09 | 26.17 | 16.40 |
August | 0.359077E+10 | 4710.23 | 14-AUG-16:00 | 26.00 | 15.86 | 0.441877E+09 | 549.50 | 11-AUG-13:00 | 26.00 | 15.86 |
September | 0.247537E+10 | 4051.55 | 13-SEP-15:30 | 23.00 | 16.22 | 0.376657E+09 | 549.51 | 19-SEP-13:00 | 14.00 | 14.00 |
October | 0.124628E+10 | 1815.15 | 06-OCT-15:50 | 17.00 | 9.21 | 0.337250E+09 | 538.32 | 06-OCT-13:00 | 17.00 | 9.21 |
November | 0.540771E+09 | 1355.10 | 10-NOV-15:30 | 11.50 | 8.42 | 0.309211E+09 | 467.82 | 10-NOV-14:00 | 11.50 | 8.42 |
December | 0.169965E+09 | 1120.64 | 21-DEC-15:20 | 7.67 | 6.81 | 0.294923E+09 | 414.78 | 21-DEC-14:00 | 7.67 | 6.81 |
Annual Sum or Average | 0.213496E+11 | 0.427994E+10 | ||||||||
Minimum of Months | 0.169965E+09 | 1120.64 | 7.67 | 5.66 | 0.281528E+09 | 414.78 | 7.67 | 5.66 | ||
Maximum of Months | 0.372198E+10 | 5454.33 | 26.42 | 17.72 | 0.441877E+09 | 549.51 | 26.42 | 17.72 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.375422E+09 | 1335.74 | 20-JAN-10:40 | 5.33 | 4.86 | 0.195597E+09 | 304.52 | 20-JAN-10:50 | 5.67 | 5.18 |
February | 0.513893E+09 | 1434.03 | 24-FEB-10:30 | 5.50 | 4.13 | 0.181050E+09 | 320.46 | 24-FEB-10:39 | 5.67 | 4.28 |
March | 0.829703E+09 | 1376.12 | 25-MAR-09:50 | 10.67 | 7.61 | 0.219159E+09 | 309.63 | 31-MAR-09:00 | 9.00 | 5.32 |
April | 0.267879E+10 | 11755.35 | 30-APR-10:23 | 19.50 | 11.92 | 0.241671E+09 | 347.89 | 14-APR-13:00 | 19.50 | 11.92 |
May | 0.314290E+10 | 10044.40 | 21-MAY-08:43 | 13.00 | 9.39 | 0.262847E+09 | 347.88 | 22-MAY-13:00 | 23.00 | 15.76 |
June | 0.383812E+10 | 12188.84 | 25-JUN-09:53 | 18.00 | 12.90 | 0.270158E+09 | 348.21 | 13-JUN-09:20 | 18.00 | 12.90 |
July | 0.408915E+10 | 13410.65 | 23-JUL-09:02 | 20.17 | 15.71 | 0.253468E+09 | 347.89 | 03-JUL-09:09 | 20.17 | 15.71 |
August | 0.427620E+10 | 10849.79 | 20-AUG-10:02 | 16.17 | 13.12 | 0.282357E+09 | 347.89 | 14-AUG-09:50 | 16.17 | 13.12 |
September | 0.314460E+10 | 6535.26 | 12-SEP-09:20 | 17.67 | 14.44 | 0.247186E+09 | 347.89 | 06-SEP-09:09 | 17.67 | 14.44 |
October | 0.130537E+10 | 3311.18 | 04-OCT-10:00 | 13.00 | 9.81 | 0.219223E+09 | 347.87 | 05-OCT-09:09 | 12.17 | 8.92 |
November | 0.521126E+09 | 1323.40 | 03-NOV-09:50 | 6.83 | 5.00 | 0.195782E+09 | 302.54 | 03-NOV-09:00 | 7.00 | 5.17 |
December | 0.206529E+09 | 1149.91 | 06-DEC-10:20 | 5.00 | 3.82 | 0.187103E+09 | 275.58 | 06-DEC-10:30 | 5.50 | 4.16 |
Annual Sum or Average | 0.249218E+11 | 0.275560E+10 | ||||||||
Minimum of Months | 0.206529E+09 | 1149.91 | 5.00 | 3.82 | 0.181050E+09 | 275.58 | 5.50 | 4.16 | ||
Maximum of Months | 0.427620E+10 | 13410.65 | 20.17 | 15.71 | 0.282357E+09 | 348.21 | 23.00 | 15.76 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.123480E+10 | 6240.59 | 20-JAN-12:00 | 8.00 | 6.08 | 0.331504E+09 | 549.49 | 17-JAN-14:30 | 8.00 | 6.08 |
February | 0.154696E+10 | 7878.71 | 17-FEB-13:40 | 6.00 | 3.25 | 0.309923E+09 | 549.49 | 24-FEB-14:20 | 6.00 | 4.60 |
March | 0.151601E+10 | 3943.94 | 28-MAR-12:17 | 11.33 | 7.17 | 0.359934E+09 | 549.50 | 28-MAR-13:09 | 10.17 | 6.99 |
April | 0.469945E+10 | 20128.31 | 30-APR-13:02 | 22.17 | 13.02 | 0.370327E+09 | 549.53 | 14-APR-13:00 | 22.17 | 13.02 |
May | 0.460207E+10 | 10123.44 | 22-MAY-13:10 | 22.17 | 14.96 | 0.402735E+09 | 549.51 | 22-MAY-13:50 | 22.83 | 15.60 |
June | 0.524966E+10 | 11541.59 | 11-JUN-13:53 | 18.00 | 14.39 | 0.417864E+09 | 549.53 | 08-JUN-13:09 | 18.00 | 14.39 |
July | 0.593627E+10 | 18759.48 | 23-JUL-12:23 | 21.50 | 16.21 | 0.393380E+09 | 549.52 | 21-JUL-13:09 | 21.50 | 16.21 |
August | 0.703306E+10 | 20560.91 | 06-AUG-13:22 | 17.50 | 13.70 | 0.440251E+09 | 549.50 | 21-AUG-13:30 | 21.00 | 14.72 |
September | 0.642082E+10 | 19359.86 | 10-SEP-11:53 | 21.00 | 15.44 | 0.384900E+09 | 549.99 | 11-SEP-13:00 | 21.00 | 15.99 |
October | 0.326869E+10 | 15330.59 | 01-OCT-13:53 | 13.00 | 9.28 | 0.356297E+09 | 549.51 | 11-OCT-13:09 | 16.00 | 10.53 |
November | 0.138579E+10 | 6854.84 | 03-NOV-12:40 | 9.00 | 5.48 | 0.328788E+09 | 549.49 | 03-NOV-13:00 | 9.00 | 5.72 |
December | 0.742193E+09 | 5217.33 | 18-DEC-13:25 | 8.00 | 5.46 | 0.310132E+09 | 549.49 | 21-DEC-14:00 | 8.00 | 6.98 |
Annual Sum or Average | 0.436358E+11 | 0.440603E+10 | ||||||||
Minimum of Months | 0.742193E+09 | 3943.94 | 6.00 | 3.25 | 0.309923E+09 | 549.49 | 6.00 | 4.60 | ||
Maximum of Months | 0.703306E+10 | 20560.91 | 22.17 | 16.21 | 0.440251E+09 | 549.99 | 22.83 | 16.21 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.370158E+09 | 1675.81 | 19-JAN-16:00 | 8.00 | 7.45 | 0.196866E+09 | 324.46 | 19-JAN-16:10 | 7.67 | 7.22 |
February | 0.568637E+09 | 2601.98 | 27-FEB-16:30 | 8.00 | 6.72 | 0.183784E+09 | 338.68 | 17-FEB-16:00 | 8.00 | 6.72 |
March | 0.853758E+09 | 2808.33 | 23-MAR-16:50 | 10.00 | 6.65 | 0.217815E+09 | 338.67 | 31-MAR-15:00 | 9.00 | 4.96 |
April | 0.262407E+10 | 14439.39 | 30-APR-16:22 | 24.00 | 12.86 | 0.221070E+09 | 347.86 | 14-APR-13:00 | 24.00 | 12.86 |
May | 0.323124E+10 | 12489.93 | 21-MAY-16:32 | 19.33 | 11.98 | 0.247180E+09 | 347.85 | 22-MAY-13:00 | 23.00 | 15.76 |
June | 0.407277E+10 | 15963.23 | 11-JUN-16:32 | 14.67 | 12.70 | 0.261420E+09 | 347.86 | 09-JUN-13:00 | 14.67 | 12.70 |
July | 0.436338E+10 | 16528.10 | 09-JUL-17:11 | 21.00 | 15.03 | 0.246671E+09 | 347.85 | 21-JUL-13:09 | 26.17 | 16.40 |
August | 0.412715E+10 | 15761.93 | 13-AUG-17:02 | 18.83 | 14.64 | 0.273537E+09 | 347.85 | 21-AUG-13:00 | 21.00 | 15.01 |
September | 0.301010E+10 | 11243.94 | 10-SEP-16:33 | 19.67 | 16.13 | 0.231952E+09 | 347.86 | 25-SEP-13:00 | 21.00 | 13.56 |
October | 0.135790E+10 | 5192.09 | 03-OCT-15:40 | 14.00 | 8.96 | 0.210519E+09 | 347.83 | 04-OCT-13:00 | 14.00 | 10.28 |
November | 0.519145E+09 | 1709.65 | 10-NOV-15:40 | 11.33 | 8.41 | 0.196327E+09 | 329.60 | 10-NOV-15:50 | 11.17 | 8.40 |
December | 0.173329E+09 | 1370.66 | 21-DEC-14:40 | 8.00 | 6.98 | 0.187122E+09 | 289.00 | 21-DEC-14:50 | 8.00 | 6.98 |
Annual Sum or Average | 0.252716E+11 | 0.267426E+10 | ||||||||
Minimum of Months | 0.173329E+09 | 1370.66 | 8.00 | 6.65 | 0.183784E+09 | 289.00 | 7.67 | 4.96 | ||
Maximum of Months | 0.436338E+10 | 16528.10 | 24.00 | 16.13 | 0.273537E+09 | 347.86 | 26.17 | 16.40 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.449425E+09 | 1210.59 | 25-JAN-15:00 | 11.00 | 9.40 | 0.310602E+09 | 438.45 | 25-JAN-14:00 | 11.00 | 9.40 |
February | 0.580179E+09 | 1181.76 | 10-FEB-16:00 | 7.00 | 5.15 | 0.282670E+09 | 431.96 | 24-FEB-14:09 | 6.00 | 4.60 |
March | 0.999718E+09 | 1329.58 | 30-MAR-14:00 | 13.00 | 7.37 | 0.346375E+09 | 467.55 | 30-MAR-13:00 | 13.00 | 7.37 |
April | 0.183242E+10 | 2220.57 | 28-APR-15:40 | 20.03 | 12.78 | 0.353470E+09 | 549.48 | 28-APR-13:00 | 20.03 | 12.78 |
May | 0.221251E+10 | 2655.61 | 23-MAY-14:00 | 19.00 | 14.77 | 0.404269E+09 | 549.49 | 22-MAY-13:00 | 19.00 | 14.77 |
June | 0.285107E+10 | 3956.43 | 13-JUN-16:00 | 26.50 | 17.70 | 0.426979E+09 | 549.50 | 09-JUN-13:00 | 26.50 | 17.70 |
July | 0.314105E+10 | 3867.46 | 21-JUL-16:00 | 28.00 | 16.11 | 0.399683E+09 | 549.49 | 18-JUL-13:09 | 28.00 | 16.11 |
August | 0.307618E+10 | 3349.84 | 14-AUG-16:00 | 26.00 | 15.86 | 0.446043E+09 | 549.50 | 11-AUG-13:00 | 26.00 | 15.86 |
September | 0.233300E+10 | 3025.93 | 13-SEP-15:30 | 23.00 | 16.22 | 0.384939E+09 | 549.49 | 28-SEP-13:00 | 16.00 | 13.03 |
October | 0.164932E+10 | 1642.47 | 02-OCT-06:02 | 10.00 | 7.49 | 0.352006E+09 | 530.98 | 02-OCT-13:20 | 13.67 | 10.58 |
November | 0.994218E+09 | 1354.99 | 10-NOV-15:00 | 12.00 | 8.42 | 0.318950E+09 | 472.81 | 10-NOV-14:00 | 12.00 | 8.42 |
December | 0.392772E+09 | 1139.20 | 21-DEC-14:50 | 8.00 | 6.98 | 0.297151E+09 | 422.73 | 21-DEC-14:00 | 8.00 | 6.98 |
Annual Sum or Average | 0.205119E+11 | 0.432314E+10 | ||||||||
Minimum of Months | 0.392772E+09 | 1139.20 | 7.00 | 5.15 | 0.282670E+09 | 422.73 | 6.00 | 4.60 | ||
Maximum of Months | 0.314105E+10 | 3956.43 | 28.00 | 17.70 | 0.446043E+09 | 549.50 | 28.00 | 17.70 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.446171E+09 | 1121.29 | 20-JAN-10:30 | 5.00 | 4.55 | 0.198205E+09 | 309.74 | 20-JAN-10:39 | 5.33 | 4.86 |
February | 0.567325E+09 | 1175.92 | 24-FEB-10:30 | 5.50 | 4.13 | 0.183740E+09 | 320.64 | 24-FEB-10:39 | 5.67 | 4.28 |
March | 0.832381E+09 | 1117.29 | 31-MAR-09:50 | 8.33 | 5.01 | 0.221405E+09 | 309.03 | 31-MAR-09:00 | 9.00 | 5.32 |
April | 0.227406E+10 | 8882.26 | 30-APR-10:13 | 19.67 | 12.19 | 0.244912E+09 | 347.89 | 14-APR-13:00 | 19.67 | 12.19 |
May | 0.267776E+10 | 7127.82 | 23-MAY-06:02 | 13.17 | 11.94 | 0.267994E+09 | 347.88 | 22-MAY-13:00 | 13.17 | 11.94 |
June | 0.328623E+10 | 8083.32 | 25-JUN-09:53 | 18.00 | 12.90 | 0.273218E+09 | 347.89 | 20-JUN-09:09 | 18.00 | 12.90 |
July | 0.360902E+10 | 10398.08 | 23-JUL-08:52 | 20.00 | 15.65 | 0.255530E+09 | 347.88 | 03-JUL-09:09 | 20.00 | 15.65 |
August | 0.385406E+10 | 6288.79 | 13-AUG-09:53 | 16.00 | 13.60 | 0.286091E+09 | 347.88 | 23-AUG-09:09 | 16.17 | 12.09 |
September | 0.299705E+10 | 5371.81 | 12-SEP-09:20 | 17.67 | 14.44 | 0.252384E+09 | 347.89 | 06-SEP-09:09 | 17.67 | 14.44 |
October | 0.150572E+10 | 3025.20 | 04-OCT-10:00 | 13.00 | 9.81 | 0.230621E+09 | 347.87 | 02-OCT-09:20 | 13.00 | 9.81 |
November | 0.825611E+09 | 1153.56 | 03-NOV-09:35 | 6.67 | 4.83 | 0.203101E+09 | 315.97 | 03-NOV-09:50 | 6.83 | 5.00 |
December | 0.372985E+09 | 1012.13 | 08-DEC-10:30 | 5.00 | 3.66 | 0.189171E+09 | 288.73 | 08-DEC-10:39 | 5.33 | 3.83 |
Annual Sum or Average | 0.232484E+11 | 0.280637E+10 | ||||||||
Minimum of Months | 0.372985E+09 | 1012.13 | 5.00 | 3.66 | 0.183740E+09 | 288.73 | 5.33 | 3.83 | ||
Maximum of Months | 0.385406E+10 | 10398.08 | 20.00 | 15.65 | 0.286091E+09 | 347.89 | 20.00 | 15.65 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.588655E+09 | 3322.29 | 21-JAN-11:30 | 6.00 | 5.05 | 0.310818E+09 | 541.57 | 17-JAN-14:09 | 6.00 | 5.05 |
February | 0.781682E+09 | 3820.43 | 04-FEB-14:00 | 9.00 | 6.13 | 0.289054E+09 | 548.28 | 17-FEB-14:00 | 6.00 | 3.38 |
March | 0.678741E+09 | 1801.26 | 25-MAR-11:50 | 11.92 | 8.82 | 0.332901E+09 | 487.94 | 28-MAR-13:09 | 10.17 | 6.99 |
April | 0.268941E+10 | 16398.41 | 30-APR-13:31 | 22.67 | 12.88 | 0.353872E+09 | 549.52 | 14-APR-13:00 | 22.67 | 12.88 |
May | 0.263752E+10 | 7323.13 | 22-MAY-13:50 | 22.83 | 15.60 | 0.385227E+09 | 549.51 | 09-MAY-13:09 | 22.83 | 15.60 |
June | 0.327613E+10 | 7662.49 | 13-JUN-13:40 | 24.73 | 17.32 | 0.405240E+09 | 549.51 | 08-JUN-13:20 | 24.73 | 17.32 |
July | 0.407192E+10 | 9193.36 | 23-JUL-13:32 | 21.33 | 16.14 | 0.389555E+09 | 549.50 | 12-JUL-13:50 | 21.33 | 16.14 |
August | 0.512752E+10 | 16285.70 | 06-AUG-13:22 | 17.50 | 13.70 | 0.441184E+09 | 549.50 | 21-AUG-13:30 | 21.00 | 14.72 |
September | 0.493826E+10 | 14243.08 | 10-SEP-13:22 | 21.00 | 15.72 | 0.388914E+09 | 549.75 | 25-SEP-13:50 | 21.17 | 13.49 |
October | 0.247294E+10 | 10472.26 | 03-OCT-12:07 | 13.00 | 9.72 | 0.352942E+09 | 549.50 | 11-OCT-13:09 | 16.00 | 10.53 |
November | 0.976263E+09 | 3849.29 | 11-NOV-13:13 | 9.00 | 7.29 | 0.316460E+09 | 549.50 | 03-NOV-13:09 | 9.00 | 7.29 |
December | 0.309236E+09 | 1952.07 | 18-DEC-13:50 | 8.00 | 5.60 | 0.293480E+09 | 547.07 | 18-DEC-14:09 | 8.00 | 5.67 |
Annual Sum or Average | 0.285483E+11 | 0.425965E+10 | ||||||||
Minimum of Months | 0.309236E+09 | 1801.26 | 6.00 | 5.05 | 0.289054E+09 | 487.94 | 6.00 | 3.38 | ||
Maximum of Months | 0.512752E+10 | 16398.41 | 24.73 | 17.32 | 0.441184E+09 | 549.75 | 24.73 | 17.32 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.443087E+09 | 1353.85 | 19-JAN-15:50 | 8.17 | 7.46 | 0.198119E+09 | 317.40 | 19-JAN-15:00 | 8.00 | 7.45 |
February | 0.628770E+09 | 1717.55 | 27-FEB-16:30 | 8.00 | 6.72 | 0.184103E+09 | 338.68 | 27-FEB-16:00 | 8.00 | 6.97 |
March | 0.874666E+09 | 1750.50 | 23-MAR-17:00 | 10.00 | 6.65 | 0.218383E+09 | 325.87 | 23-MAR-15:00 | 10.00 | 6.65 |
April | 0.211512E+10 | 12390.53 | 30-APR-17:31 | 24.00 | 12.95 | 0.226664E+09 | 347.84 | 28-APR-13:00 | 24.00 | 12.95 |
May | 0.267177E+10 | 8714.36 | 21-MAY-16:52 | 20.00 | 12.79 | 0.257224E+09 | 347.85 | 22-MAY-13:00 | 23.00 | 15.76 |
June | 0.341667E+10 | 12499.57 | 11-JUN-16:32 | 14.67 | 12.70 | 0.269747E+09 | 347.85 | 09-JUN-13:00 | 14.67 | 12.70 |
July | 0.378626E+10 | 12204.15 | 09-JUL-17:41 | 21.00 | 15.03 | 0.253276E+09 | 347.85 | 12-JUL-13:00 | 21.00 | 15.44 |
August | 0.356066E+10 | 11051.18 | 06-AUG-16:42 | 18.67 | 13.29 | 0.283418E+09 | 347.85 | 15-AUG-09:09 | 16.00 | 13.59 |
September | 0.267436E+10 | 6112.63 | 12-SEP-16:00 | 21.00 | 15.99 | 0.244691E+09 | 347.85 | 25-SEP-13:00 | 21.00 | 13.56 |
October | 0.156352E+10 | 4399.97 | 03-OCT-16:00 | 14.00 | 8.96 | 0.221829E+09 | 347.83 | 04-OCT-13:00 | 14.00 | 10.28 |
November | 0.844614E+09 | 1415.75 | 10-NOV-15:40 | 11.33 | 8.41 | 0.200701E+09 | 328.39 | 10-NOV-15:50 | 11.17 | 8.40 |
December | 0.289329E+09 | 1151.91 | 21-DEC-14:50 | 8.00 | 6.98 | 0.188311E+09 | 290.87 | 21-DEC-14:00 | 8.00 | 6.98 |
Annual Sum or Average | 0.228688E+11 | 0.274647E+10 | ||||||||
Minimum of Months | 0.289329E+09 | 1151.91 | 8.00 | 6.65 | 0.184103E+09 | 290.87 | 8.00 | 6.65 | ||
Maximum of Months | 0.378626E+10 | 12499.57 | 24.00 | 15.99 | 0.283418E+09 | 347.85 | 24.00 | 15.76 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.599561E+09 | 1295.68 | 19-JAN-15:40 | 8.33 | 7.46 | 0.314914E+09 | 462.39 | 19-JAN-14:00 | 8.33 | 7.46 |
February | 0.763337E+09 | 1286.71 | 24-FEB-16:00 | 6.00 | 4.60 | 0.290029E+09 | 459.20 | 24-FEB-14:09 | 6.00 | 4.60 |
March | 0.129690E+10 | 1448.50 | 30-MAR-15:40 | 12.00 | 6.06 | 0.360160E+09 | 502.02 | 30-MAR-13:00 | 12.00 | 6.06 |
April | 0.216461E+10 | 3600.68 | 28-APR-15:30 | 20.05 | 13.01 | 0.373913E+09 | 549.50 | 14-APR-13:00 | 20.05 | 13.01 |
May | 0.271795E+10 | 3962.60 | 22-MAY-15:20 | 23.67 | 15.81 | 0.419348E+09 | 549.50 | 22-MAY-13:00 | 23.67 | 15.81 |
June | 0.359636E+10 | 5016.37 | 13-JUN-16:00 | 26.50 | 17.70 | 0.431299E+09 | 549.51 | 08-JUN-13:09 | 26.50 | 17.70 |
July | 0.384401E+10 | 4825.49 | 10-JUL-15:00 | 23.00 | 16.69 | 0.401610E+09 | 549.50 | 31-JUL-09:09 | 14.17 | 10.78 |
August | 0.376049E+10 | 4436.03 | 14-AUG-16:00 | 26.00 | 15.86 | 0.449339E+09 | 549.50 | 15-AUG-09:09 | 16.00 | 13.59 |
September | 0.270820E+10 | 3943.28 | 13-SEP-15:30 | 23.00 | 16.22 | 0.389872E+09 | 549.51 | 19-SEP-13:50 | 14.33 | 13.96 |
October | 0.167336E+10 | 2114.59 | 06-OCT-15:40 | 17.00 | 9.21 | 0.358482E+09 | 549.48 | 02-OCT-13:50 | 17.00 | 9.21 |
November | 0.100794E+10 | 1389.29 | 10-NOV-15:30 | 11.50 | 8.42 | 0.321422E+09 | 486.70 | 10-NOV-14:00 | 11.50 | 8.42 |
December | 0.456086E+09 | 1174.68 | 21-DEC-15:10 | 7.83 | 6.90 | 0.298277E+09 | 435.58 | 21-DEC-14:00 | 7.83 | 6.90 |
Annual Sum or Average | 0.245888E+11 | 0.440867E+10 | ||||||||
Minimum of Months | 0.456086E+09 | 1174.68 | 6.00 | 4.60 | 0.290029E+09 | 435.58 | 6.00 | 4.60 | ||
Maximum of Months | 0.384401E+10 | 5016.37 | 26.50 | 17.70 | 0.449339E+09 | 549.51 | 26.50 | 17.70 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.574946E+09 | 1455.88 | 20-JAN-10:00 | 4.00 | 3.60 | 0.146112E+09 | 310.23 | 20-JAN-09:00 | 4.00 | 3.60 |
February | 0.738692E+09 | 1575.29 | 17-FEB-10:00 | 3.00 | 2.16 | 0.136059E+09 | 331.55 | 17-FEB-09:00 | 3.00 | 2.16 |
March | 0.114206E+10 | 1496.48 | 25-MAR-09:50 | 10.67 | 7.61 | 0.164689E+09 | 317.35 | 30-MAR-10:39 | 9.67 | 6.89 |
April | 0.293389E+10 | 10538.41 | 30-APR-10:43 | 19.17 | 11.38 | 0.179969E+09 | 338.79 | 28-APR-07:49 | 19.17 | 11.38 |
May | 0.334542E+10 | 12260.42 | 21-MAY-08:43 | 13.00 | 9.39 | 0.196446E+09 | 338.72 | 22-MAY-14:09 | 23.17 | 15.81 |
June | 0.390191E+10 | 11960.78 | 11-JUN-09:23 | 16.00 | 13.04 | 0.200585E+09 | 338.93 | 13-JUN-08:00 | 21.60 | 15.95 |
July | 0.415671E+10 | 13576.42 | 23-JUL-08:42 | 19.83 | 15.59 | 0.188337E+09 | 338.73 | 31-JUL-08:09 | 14.83 | 10.71 |
August | 0.436434E+10 | 11321.47 | 13-AUG-09:53 | 16.00 | 13.60 | 0.209434E+09 | 338.74 | 21-AUG-07:10 | 14.33 | 12.39 |
September | 0.339292E+10 | 6994.50 | 12-SEP-09:00 | 18.00 | 14.38 | 0.184152E+09 | 338.73 | 21-SEP-08:09 | 13.00 | 11.30 |
October | 0.170468E+10 | 4096.06 | 03-OCT-09:00 | 12.00 | 9.31 | 0.165970E+09 | 338.72 | 02-OCT-10:30 | 12.00 | 9.31 |
November | 0.865617E+09 | 1435.27 | 03-NOV-10:30 | 8.00 | 5.31 | 0.147474E+09 | 310.64 | 03-NOV-10:30 | 8.00 | 5.31 |
December | 0.390681E+09 | 1278.32 | 06-DEC-10:00 | 4.00 | 3.12 | 0.139043E+09 | 284.81 | 06-DEC-09:00 | 4.00 | 3.12 |
Annual Sum or Average | 0.275119E+11 | 0.205827E+10 | ||||||||
Minimum of Months | 0.390681E+09 | 1278.32 | 3.00 | 2.16 | 0.136059E+09 | 284.81 | 3.00 | 2.16 | ||
Maximum of Months | 0.436434E+10 | 13576.42 | 19.83 | 15.59 | 0.209434E+09 | 338.93 | 23.17 | 15.95 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.168309E+10 | 7211.07 | 20-JAN-12:00 | 8.00 | 6.08 | 0.340878E+09 | 549.50 | 20-JAN-10:30 | 8.00 | 6.08 |
February | 0.205042E+10 | 8431.12 | 17-FEB-13:40 | 6.00 | 3.25 | 0.319867E+09 | 549.50 | 17-FEB-10:39 | 6.00 | 3.25 |
March | 0.201576E+10 | 4578.83 | 28-MAR-12:05 | 11.67 | 7.18 | 0.373766E+09 | 549.50 | 28-MAR-13:09 | 10.17 | 6.99 |
April | 0.498939E+10 | 18898.70 | 30-APR-13:22 | 22.50 | 12.93 | 0.381529E+09 | 549.82 | 28-APR-13:09 | 22.50 | 12.93 |
May | 0.478972E+10 | 11434.44 | 21-MAY-13:43 | 17.00 | 10.30 | 0.416629E+09 | 549.51 | 22-MAY-13:50 | 22.83 | 15.60 |
June | 0.527663E+10 | 9429.04 | 13-JUN-13:10 | 24.18 | 17.12 | 0.426898E+09 | 549.53 | 08-JUN-13:09 | 24.18 | 17.12 |
July | 0.595449E+10 | 17913.15 | 23-JUL-12:43 | 21.83 | 16.36 | 0.399631E+09 | 549.50 | 12-JUL-13:50 | 21.83 | 16.36 |
August | 0.708779E+10 | 18725.84 | 13-AUG-13:13 | 21.00 | 15.45 | 0.448322E+09 | 549.50 | 11-AUG-13:00 | 21.00 | 15.45 |
September | 0.674005E+10 | 19620.75 | 24-SEP-13:12 | 19.67 | 15.02 | 0.393880E+09 | 550.03 | 27-SEP-13:00 | 22.00 | 13.55 |
October | 0.389687E+10 | 11625.19 | 03-OCT-13:10 | 13.17 | 9.32 | 0.371531E+09 | 549.76 | 03-OCT-13:00 | 14.00 | 9.41 |
November | 0.199097E+10 | 7666.44 | 03-NOV-12:25 | 9.00 | 5.54 | 0.341527E+09 | 549.49 | 03-NOV-13:00 | 9.00 | 5.72 |
December | 0.109841E+10 | 5945.77 | 18-DEC-13:25 | 8.00 | 5.46 | 0.318350E+09 | 549.49 | 26-DEC-14:00 | 6.00 | 3.37 |
Annual Sum or Average | 0.475736E+11 | 0.453281E+10 | ||||||||
Minimum of Months | 0.109841E+10 | 4578.83 | 6.00 | 3.25 | 0.318350E+09 | 549.49 | 6.00 | 3.25 | ||
Maximum of Months | 0.708779E+10 | 19620.75 | 24.18 | 17.12 | 0.448322E+09 | 550.03 | 24.18 | 17.12 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.605795E+09 | 1643.94 | 19-JAN-15:50 | 8.17 | 7.46 | 0.199894E+09 | 335.43 | 19-JAN-15:00 | 8.00 | 7.45 |
February | 0.848702E+09 | 2788.49 | 27-FEB-16:30 | 8.00 | 6.72 | 0.187441E+09 | 342.07 | 09-FEB-14:00 | 8.00 | 6.72 |
March | 0.120908E+10 | 3069.75 | 23-MAR-16:40 | 10.00 | 6.65 | 0.223694E+09 | 338.68 | 10-MAR-16:49 | 10.00 | 6.65 |
April | 0.277602E+10 | 13329.47 | 30-APR-16:42 | 24.00 | 12.67 | 0.230035E+09 | 347.86 | 14-APR-13:00 | 24.00 | 12.67 |
May | 0.333957E+10 | 14806.26 | 21-MAY-17:02 | 20.00 | 12.86 | 0.257505E+09 | 347.85 | 22-MAY-13:00 | 23.00 | 15.76 |
June | 0.406662E+10 | 13238.41 | 25-JUN-16:52 | 21.00 | 14.00 | 0.268427E+09 | 347.86 | 09-JUN-13:00 | 21.00 | 14.00 |
July | 0.435616E+10 | 14338.86 | 30-JUL-16:22 | 15.00 | 11.37 | 0.251793E+09 | 347.85 | 12-JUL-13:00 | 15.00 | 11.37 |
August | 0.413775E+10 | 12545.15 | 20-AUG-16:12 | 23.33 | 14.80 | 0.281015E+09 | 347.85 | 11-AUG-13:00 | 23.33 | 14.80 |
September | 0.313676E+10 | 11422.67 | 10-SEP-16:12 | 20.33 | 16.35 | 0.241561E+09 | 347.86 | 25-SEP-13:00 | 21.00 | 13.56 |
October | 0.175121E+10 | 5357.63 | 03-OCT-15:40 | 14.00 | 8.96 | 0.220120E+09 | 347.83 | 04-OCT-13:00 | 14.00 | 10.28 |
November | 0.907221E+09 | 1806.11 | 10-NOV-15:40 | 11.33 | 8.41 | 0.200824E+09 | 341.11 | 15-NOV-14:00 | 12.00 | 8.90 |
December | 0.367304E+09 | 1382.18 | 21-DEC-14:40 | 8.00 | 6.98 | 0.188629E+09 | 303.26 | 21-DEC-14:50 | 8.00 | 6.98 |
Annual Sum or Average | 0.275022E+11 | 0.275094E+10 | ||||||||
Minimum of Months | 0.367304E+09 | 1382.18 | 8.00 | 6.65 | 0.187441E+09 | 303.26 | 8.00 | 6.65 | ||
Maximum of Months | 0.435616E+10 | 14806.26 | 24.00 | 16.35 | 0.281015E+09 | 347.86 | 24.00 | 15.76 |
Report: ZoneHeatingSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 1092327.47 | 2396.81 | 02-JAN-07:01 | 1.83 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 7.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 3.80 |
April | 0.00 | 0.00 | 01-APR-00:10 | 4.23 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 7.57 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 6.57 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 4.00 |
Annual Sum or Average | 1092327.47 | |||
Minimum of Months | 0.00 | 0.00 | 1.83 | |
Maximum of Months | 1092327.47 | 2396.81 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.305299E+10 | 11090.03 | 09-JAN-06:10 | -2.0 |
February | 0.207032E+10 | 9881.13 | 17-FEB-07:12 | -3.7 |
March | 0.180834E+10 | 9115.94 | 27-MAR-06:12 | 0.67 |
April | 0.727307E+09 | 4711.45 | 01-APR-06:03 | 3.17 |
May | 0.495423E+09 | 4119.91 | 03-MAY-05:03 | 3.50 |
June | 0.239250E+09 | 4064.09 | 01-JUN-05:03 | 6.50 |
July | 0.197251E+09 | 3896.23 | 30-JUL-07:30 | 14.00 |
August | 0.304821E+09 | 4035.79 | 20-AUG-07:23 | 15.00 |
September | 0.490672E+09 | 4163.68 | 24-SEP-08:28 | 17.00 |
October | 0.123395E+10 | 6391.32 | 23-OCT-06:03 | 4.00 |
November | 0.210049E+10 | 9374.15 | 20-NOV-07:06 | 1.00 |
December | 0.339408E+10 | 11262.61 | 04-DEC-06:19 | 3.00 |
Annual Sum or Average | 0.161149E+11 | |||
Minimum of Months | 0.197251E+09 | 3896.23 | -3.7 | |
Maximum of Months | 0.339408E+10 | 11262.61 | 17.00 |
Report: ZoneHeatingSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.146915E+10 | 6661.38 | 02-JAN-07:12 | 1.67 |
February | 0.100790E+10 | 4126.80 | 19-FEB-14:17 | 6.00 |
March | 0.866838E+09 | 3095.58 | 06-MAR-07:12 | 4.67 |
April | 0.239560E+09 | 5327.19 | 30-APR-10:43 | 19.17 |
May | 0.131283E+09 | 3625.89 | 21-MAY-08:43 | 13.00 |
June | 17993555.91 | 3244.65 | 18-JUN-09:02 | 13.98 |
July | 32158911.03 | 4188.98 | 30-JUL-15:02 | 16.83 |
August | 23976531.17 | 4839.98 | 13-AUG-15:13 | 21.00 |
September | 55558274.45 | 5116.43 | 24-SEP-15:53 | 22.00 |
October | 0.496644E+09 | 2764.41 | 01-OCT-10:10 | 13.17 |
November | 0.940221E+09 | 3780.73 | 27-NOV-07:13 | 4.00 |
December | 0.149485E+10 | 5715.84 | 26-DEC-07:08 | 1.83 |
Annual Sum or Average | 0.677613E+10 | |||
Minimum of Months | 17993555.91 | 2764.41 | 1.67 | |
Maximum of Months | 0.149485E+10 | 6661.38 | 22.00 |
Report: ZoneHeatingSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.102469E+10 | 3748.87 | 02-JAN-07:01 | 1.83 |
February | 0.639561E+09 | 2480.10 | 17-FEB-08:30 | -1.0 |
March | 0.579588E+09 | 2237.68 | 16-MAR-07:20 | 2.67 |
April | 38646143.97 | 4350.32 | 20-APR-05:03 | 1.17 |
May | 22449458.12 | 2361.60 | 07-MAY-15:47 | 14.00 |
June | 20733578.44 | 2101.33 | 18-JUN-16:23 | 14.00 |
July | 28507456.45 | 2447.83 | 05-JUL-05:12 | 7.67 |
August | 23863970.32 | 2308.92 | 06-AUG-15:22 | 17.50 |
September | 33059208.34 | 3070.87 | 17-SEP-11:15 | 15.33 |
October | 0.206724E+09 | 2428.71 | 01-OCT-09:53 | 13.00 |
November | 0.593690E+09 | 2578.97 | 11-NOV-13:13 | 9.00 |
December | 0.110406E+10 | 2777.21 | 26-DEC-08:20 | 1.33 |
Annual Sum or Average | 0.431558E+10 | |||
Minimum of Months | 20733578.44 | 2101.33 | -1.0 | |
Maximum of Months | 0.110406E+10 | 4350.32 | 17.50 |
Report: ZoneHeatingSummaryMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.101282E+09 | 10812.48 | 02-JAN-06:02 | 1.17 |
February | 7930505.35 | 8028.88 | 27-FEB-07:02 | 6.00 |
March | 4760355.50 | 8222.38 | 06-MAR-07:01 | 4.33 |
April | 0.00 | 0.00 | 01-APR-00:10 | 4.23 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 7.57 |
November | 7238953.10 | 8192.25 | 27-NOV-07:01 | 4.00 |
December | 54645286.15 | 8723.00 | 26-DEC-06:11 | 1.93 |
Annual Sum or Average | 0.175857E+09 | |||
Minimum of Months | 0.00 | 0.00 | 1.17 | |
Maximum of Months | 0.101282E+09 | 10812.48 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.746325E+09 | 19518.75 | 02-JAN-05:01 | 1.00 |
February | 0.305031E+09 | 16716.35 | 13-FEB-06:02 | -1.0 |
March | 0.203603E+09 | 16570.45 | 06-MAR-06:11 | 4.00 |
April | 4807207.89 | 14095.42 | 03-APR-06:02 | 3.17 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
October | 42113632.91 | 14670.51 | 23-OCT-06:03 | 4.00 |
November | 0.266783E+09 | 16833.48 | 27-NOV-06:11 | 4.00 |
December | 0.743136E+09 | 18540.14 | 26-DEC-06:11 | 1.93 |
Annual Sum or Average | 0.231180E+10 | |||
Minimum of Months | 0.00 | 0.00 | -1.0 | |
Maximum of Months | 0.746325E+09 | 19518.75 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.171399E+10 | 7133.89 | 09-JAN-05:01 | -2.1 |
February | 0.102052E+10 | 6698.01 | 13-FEB-05:02 | -1.0 |
March | 0.664039E+09 | 6554.32 | 06-MAR-06:11 | 4.00 |
April | 67388077.25 | 5705.59 | 01-APR-05:12 | 2.33 |
May | 7437430.66 | 5266.37 | 05-MAY-06:03 | 6.17 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
September | 3767555.83 | 5257.57 | 21-SEP-06:03 | 5.33 |
October | 0.218355E+09 | 6151.20 | 23-OCT-05:11 | 3.33 |
November | 0.830704E+09 | 6702.94 | 27-NOV-06:11 | 4.00 |
December | 0.192183E+10 | 7078.32 | 18-DEC-05:01 | 0.83 |
Annual Sum or Average | 0.644804E+10 | |||
Minimum of Months | 0.00 | 0.00 | -2.1 | |
Maximum of Months | 0.192183E+10 | 7133.89 | 11.43 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.982089E+09 | 6631.54 | 09-JAN-05:01 | -2.1 |
February | 0.565574E+09 | 5951.97 | 13-FEB-05:02 | -1.0 |
March | 0.389842E+09 | 5881.59 | 06-MAR-06:11 | 4.00 |
April | 18414704.85 | 4737.04 | 01-APR-05:12 | 2.33 |
May | 3623619.62 | 4199.90 | 17-MAY-06:03 | 6.17 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
September | 2574264.13 | 4154.50 | 20-SEP-06:03 | 6.17 |
October | 0.129985E+09 | 5325.22 | 23-OCT-05:11 | 3.33 |
November | 0.481010E+09 | 6054.97 | 27-NOV-06:11 | 4.00 |
December | 0.116250E+10 | 6540.33 | 18-DEC-05:01 | 0.83 |
Annual Sum or Average | 0.373561E+10 | |||
Minimum of Months | 0.00 | 0.00 | -2.1 | |
Maximum of Months | 0.116250E+10 | 6631.54 | 11.43 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.114252E+10 | 9866.92 | 02-JAN-05:01 | 1.00 |
February | 0.658621E+09 | 8755.86 | 13-FEB-05:02 | -1.0 |
March | 0.544676E+09 | 8857.52 | 06-MAR-06:11 | 4.00 |
April | 59460380.33 | 7041.28 | 01-APR-05:12 | 2.33 |
May | 18384307.81 | 6426.16 | 06-MAY-06:03 | 3.50 |
June | 450540.24 | 2252.70 | 08-JUN-06:03 | 7.50 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
September | 3738866.52 | 6316.02 | 20-SEP-06:03 | 6.17 |
October | 0.165964E+09 | 7822.01 | 23-OCT-05:11 | 3.33 |
November | 0.574264E+09 | 9089.32 | 27-NOV-06:11 | 4.00 |
December | 0.151045E+10 | 9685.95 | 26-DEC-06:11 | 1.93 |
Annual Sum or Average | 0.467853E+10 | |||
Minimum of Months | 0.00 | 0.00 | -1.0 | |
Maximum of Months | 0.151045E+10 | 9866.92 | 11.43 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.104145E+10 | 6835.86 | 02-JAN-05:01 | 1.00 |
February | 0.586872E+09 | 6202.61 | 13-FEB-05:02 | -1.0 |
March | 0.422119E+09 | 6074.65 | 06-MAR-06:11 | 4.00 |
April | 45759553.75 | 4755.36 | 01-APR-05:12 | 2.33 |
May | 12913933.05 | 4227.33 | 05-MAY-06:03 | 6.17 |
June | 237502.13 | 1187.51 | 08-JUN-06:03 | 7.50 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
September | 5194001.79 | 4205.11 | 20-SEP-06:03 | 6.17 |
October | 0.148350E+09 | 5414.66 | 23-OCT-05:11 | 3.33 |
November | 0.530807E+09 | 6296.13 | 27-NOV-06:11 | 4.00 |
December | 0.127558E+10 | 6787.19 | 18-DEC-05:01 | 0.83 |
Annual Sum or Average | 0.406929E+10 | |||
Minimum of Months | 0.00 | 0.00 | -1.0 | |
Maximum of Months | 0.127558E+10 | 6835.86 | 11.43 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.904269E+09 | 5349.24 | 02-JAN-05:01 | 1.00 |
February | 0.385070E+09 | 4679.29 | 13-FEB-06:02 | -1.0 |
March | 0.220897E+09 | 4651.30 | 06-MAR-06:11 | 4.00 |
April | 11029647.30 | 4234.26 | 03-APR-06:02 | 3.17 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
October | 14367862.93 | 4215.43 | 23-OCT-06:03 | 4.00 |
November | 0.149556E+09 | 4567.57 | 27-NOV-06:11 | 4.00 |
December | 0.706724E+09 | 4862.96 | 26-DEC-06:11 | 1.93 |
Annual Sum or Average | 0.239191E+10 | |||
Minimum of Months | 0.00 | 0.00 | -1.0 | |
Maximum of Months | 0.904269E+09 | 5349.24 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.476134E+09 | 4739.92 | 02-JAN-05:01 | 1.00 |
February | 0.182646E+09 | 3987.24 | 17-FEB-06:01 | -3.1 |
March | 0.124254E+09 | 4054.63 | 06-MAR-06:11 | 4.00 |
April | 1284539.41 | 3351.43 | 01-APR-06:03 | 3.17 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
October | 10075416.76 | 3371.65 | 23-OCT-06:03 | 4.00 |
November | 86563195.20 | 3877.42 | 27-NOV-06:11 | 4.00 |
December | 0.439166E+09 | 4281.78 | 26-DEC-06:11 | 1.93 |
Annual Sum or Average | 0.132012E+10 | |||
Minimum of Months | 0.00 | 0.00 | -3.1 | |
Maximum of Months | 0.476134E+09 | 4739.92 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.250716E+10 | 8846.27 | 10-JAN-07:50 | -5.7 |
February | 0.172535E+10 | 8819.57 | 17-FEB-07:10 | -3.8 |
March | 0.210271E+10 | 8160.28 | 08-MAR-07:10 | -0.5 |
April | 0.684130E+09 | 6682.94 | 03-APR-06:10 | 3.17 |
May | 0.687672E+09 | 6220.40 | 05-MAY-06:10 | 6.17 |
June | 0.277922E+09 | 5630.50 | 08-JUN-06:10 | 7.50 |
July | 97941305.33 | 5140.84 | 05-JUL-06:10 | 9.50 |
August | 82370622.10 | 5162.12 | 24-AUG-06:10 | 8.83 |
September | 0.239217E+09 | 5746.95 | 21-SEP-06:10 | 5.33 |
October | 0.873953E+09 | 6473.98 | 23-OCT-06:50 | 4.00 |
November | 0.158616E+10 | 8028.14 | 29-NOV-07:10 | -1.0 |
December | 0.254580E+10 | 8352.75 | 27-DEC-07:10 | -1.8 |
Annual Sum or Average | 0.134104E+11 | |||
Minimum of Months | 82370622.10 | 5140.84 | -5.7 | |
Maximum of Months | 0.254580E+10 | 8846.27 | 9.50 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.505816E+09 | 4986.08 | 02-JAN-05:01 | 1.00 |
February | 0.158972E+09 | 4079.00 | 13-FEB-06:02 | -1.0 |
March | 0.129958E+09 | 4143.13 | 06-MAR-06:11 | 4.00 |
April | 5471515.86 | 3412.78 | 03-APR-06:02 | 3.17 |
May | 409582.49 | 1379.32 | 05-MAY-06:03 | 6.17 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
October | 11467422.03 | 3377.72 | 30-OCT-06:03 | 6.83 |
November | 96414433.38 | 4024.75 | 27-NOV-06:11 | 4.00 |
December | 0.488562E+09 | 4419.39 | 26-DEC-06:11 | 1.93 |
Annual Sum or Average | 0.139707E+10 | |||
Minimum of Months | 0.00 | 0.00 | -1.0 | |
Maximum of Months | 0.505816E+09 | 4986.08 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.652317E+09 | 5671.61 | 02-JAN-05:01 | 1.00 |
February | 0.240307E+09 | 4932.71 | 13-FEB-06:02 | -1.0 |
March | 0.133397E+09 | 4877.15 | 06-MAR-06:11 | 4.00 |
April | 4116224.43 | 4333.45 | 01-APR-06:03 | 3.17 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
October | 22357292.51 | 4365.24 | 23-OCT-06:03 | 4.00 |
November | 0.191097E+09 | 4954.37 | 27-NOV-06:11 | 4.00 |
December | 0.715156E+09 | 5332.88 | 26-DEC-06:11 | 1.93 |
Annual Sum or Average | 0.195875E+10 | |||
Minimum of Months | 0.00 | 0.00 | -1.0 | |
Maximum of Months | 0.715156E+09 | 5671.61 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.399303E+09 | 5272.94 | 02-JAN-05:01 | 1.00 |
February | 0.145844E+09 | 4194.75 | 13-FEB-06:02 | -1.0 |
March | 85819121.01 | 4232.23 | 06-MAR-06:11 | 4.00 |
April | 2201272.58 | 3310.84 | 03-APR-06:02 | 3.17 |
May | 10815.61 | 72.10 | 17-MAY-06:03 | 6.17 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
October | 18344602.26 | 3373.37 | 23-OCT-06:03 | 4.00 |
November | 0.123201E+09 | 4324.43 | 27-NOV-06:11 | 4.00 |
December | 0.475144E+09 | 4855.26 | 26-DEC-06:11 | 1.93 |
Annual Sum or Average | 0.124987E+10 | |||
Minimum of Months | 0.00 | 0.00 | -1.0 | |
Maximum of Months | 0.475144E+09 | 5272.94 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.402419E+09 | 7390.71 | 02-JAN-05:01 | 1.00 |
February | 0.139493E+09 | 6046.59 | 27-FEB-06:11 | 6.00 |
March | 0.108413E+09 | 6230.31 | 06-MAR-06:11 | 4.00 |
April | 4446595.41 | 5071.31 | 01-APR-06:03 | 3.17 |
May | 372514.13 | 1941.10 | 05-MAY-06:03 | 6.17 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
October | 19915725.46 | 5104.84 | 23-OCT-06:03 | 4.00 |
November | 0.125035E+09 | 6334.26 | 27-NOV-06:11 | 4.00 |
December | 0.519664E+09 | 6915.64 | 26-DEC-06:11 | 1.93 |
Annual Sum or Average | 0.131976E+10 | |||
Minimum of Months | 0.00 | 0.00 | 1.00 | |
Maximum of Months | 0.519664E+09 | 7390.71 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.399102E+09 | 5314.79 | 02-JAN-05:01 | 1.00 |
February | 0.140932E+09 | 4251.37 | 13-FEB-06:02 | -1.0 |
March | 91826652.27 | 4238.68 | 06-MAR-06:11 | 4.00 |
April | 4643770.97 | 3357.26 | 03-APR-06:02 | 3.17 |
May | 482185.06 | 2278.58 | 05-MAY-06:03 | 6.17 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
October | 18410383.67 | 3346.79 | 23-OCT-06:03 | 4.00 |
November | 0.131250E+09 | 4364.54 | 27-NOV-06:11 | 4.00 |
December | 0.490251E+09 | 4880.95 | 26-DEC-06:11 | 1.93 |
Annual Sum or Average | 0.127690E+10 | |||
Minimum of Months | 0.00 | 0.00 | -1.0 | |
Maximum of Months | 0.490251E+09 | 5314.79 | 12.43 |
Report: ZoneElectricSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.599791E+10 | 6443.98 | 02-JAN-08:09 | 0.210964E+11 | 14019.75 | 02-JAN-08:09 |
February | 0.544142E+10 | 6443.98 | 01-FEB-08:09 | 0.191215E+11 | 14019.75 | 01-FEB-08:09 |
March | 0.648083E+10 | 6443.98 | 01-MAR-08:09 | 0.217104E+11 | 14019.75 | 01-MAR-08:09 |
April | 0.577357E+10 | 6443.98 | 03-APR-07:10 | 0.204846E+11 | 14019.75 | 03-APR-07:10 |
May | 0.623937E+10 | 6443.98 | 01-MAY-07:10 | 0.214034E+11 | 14019.75 | 01-MAY-07:10 |
June | 0.621476E+10 | 6443.98 | 01-JUN-07:10 | 0.209475E+11 | 14019.75 | 01-JUN-07:10 |
July | 0.579818E+10 | 6443.98 | 03-JUL-07:10 | 0.209382E+11 | 14019.75 | 03-JUL-07:10 |
August | 0.648074E+10 | 6443.98 | 01-AUG-07:10 | 0.217104E+11 | 14019.75 | 01-AUG-07:10 |
September | 0.577357E+10 | 6443.98 | 01-SEP-07:10 | 0.204802E+11 | 14019.75 | 01-SEP-07:10 |
October | 0.599800E+10 | 6443.98 | 02-OCT-07:10 | 0.210986E+11 | 14019.75 | 02-OCT-07:10 |
November | 0.593174E+10 | 6443.98 | 01-NOV-07:10 | 0.204961E+11 | 14019.75 | 01-NOV-07:10 |
December | 0.579827E+10 | 6443.98 | 01-DEC-08:09 | 0.209360E+11 | 14019.75 | 01-DEC-08:09 |
Annual Sum or Average | 0.719283E+11 | 0.250423E+12 | ||||
Minimum of Months | 0.544142E+10 | 6443.98 | 0.191215E+11 | 14019.75 | ||
Maximum of Months | 0.648083E+10 | 6443.98 | 0.217104E+11 | 14019.75 |
Report: ZoneElectricSummaryMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.599791E+10 | 6443.98 | 02-JAN-08:09 | 0.971303E+10 | 6808.32 | 02-JAN-08:09 |
February | 0.544142E+10 | 6443.98 | 01-FEB-08:09 | 0.879311E+10 | 6808.32 | 01-FEB-08:09 |
March | 0.648083E+10 | 6443.98 | 01-MAR-08:09 | 0.101015E+11 | 6808.32 | 01-MAR-08:09 |
April | 0.577357E+10 | 6443.98 | 03-APR-07:10 | 0.937947E+10 | 6808.32 | 03-APR-07:10 |
May | 0.623937E+10 | 6443.98 | 01-MAY-07:10 | 0.990724E+10 | 6808.32 | 01-MAY-07:10 |
June | 0.621476E+10 | 6443.98 | 01-JUN-07:10 | 0.972788E+10 | 6808.32 | 01-JUN-07:10 |
July | 0.579818E+10 | 6443.98 | 03-JUL-07:10 | 0.955663E+10 | 6808.32 | 03-JUL-07:10 |
August | 0.648074E+10 | 6443.98 | 01-AUG-07:10 | 0.101015E+11 | 6808.32 | 01-AUG-07:10 |
September | 0.577357E+10 | 6443.98 | 01-SEP-07:10 | 0.937507E+10 | 6808.32 | 01-SEP-07:10 |
October | 0.599800E+10 | 6443.98 | 02-OCT-07:10 | 0.971523E+10 | 6808.32 | 02-OCT-07:10 |
November | 0.593174E+10 | 6443.98 | 01-NOV-07:10 | 0.950025E+10 | 6808.32 | 01-NOV-07:10 |
December | 0.579827E+10 | 6443.98 | 01-DEC-08:09 | 0.955443E+10 | 6808.32 | 01-DEC-08:09 |
Annual Sum or Average | 0.719283E+11 | 0.115425E+12 | ||||
Minimum of Months | 0.544142E+10 | 6443.98 | 0.879311E+10 | 6808.32 | ||
Maximum of Months | 0.648083E+10 | 6443.98 | 0.101015E+11 | 6808.32 |
Report: ZoneElectricSummaryMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.599791E+10 | 6443.98 | 02-JAN-08:09 | 0.971303E+10 | 6808.32 | 02-JAN-08:09 |
February | 0.544142E+10 | 6443.98 | 01-FEB-08:09 | 0.879311E+10 | 6808.32 | 01-FEB-08:09 |
March | 0.648083E+10 | 6443.98 | 01-MAR-08:09 | 0.101015E+11 | 6808.32 | 01-MAR-08:09 |
April | 0.577357E+10 | 6443.98 | 03-APR-07:10 | 0.937947E+10 | 6808.32 | 03-APR-07:10 |
May | 0.623937E+10 | 6443.98 | 01-MAY-07:10 | 0.990724E+10 | 6808.32 | 01-MAY-07:10 |
June | 0.621476E+10 | 6443.98 | 01-JUN-07:10 | 0.972788E+10 | 6808.32 | 01-JUN-07:10 |
July | 0.579818E+10 | 6443.98 | 03-JUL-07:10 | 0.955663E+10 | 6808.32 | 03-JUL-07:10 |
August | 0.648074E+10 | 6443.98 | 01-AUG-07:10 | 0.101015E+11 | 6808.32 | 01-AUG-07:10 |
September | 0.577357E+10 | 6443.98 | 01-SEP-07:10 | 0.937507E+10 | 6808.32 | 01-SEP-07:10 |
October | 0.599800E+10 | 6443.98 | 02-OCT-07:10 | 0.971523E+10 | 6808.32 | 02-OCT-07:10 |
November | 0.593174E+10 | 6443.98 | 01-NOV-07:10 | 0.950025E+10 | 6808.32 | 01-NOV-07:10 |
December | 0.579827E+10 | 6443.98 | 01-DEC-08:09 | 0.955443E+10 | 6808.32 | 01-DEC-08:09 |
Annual Sum or Average | 0.719283E+11 | 0.115425E+12 | ||||
Minimum of Months | 0.544142E+10 | 6443.98 | 0.879311E+10 | 6808.32 | ||
Maximum of Months | 0.648083E+10 | 6443.98 | 0.101015E+11 | 6808.32 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.912524E+09 | 1358.45 | 02-JAN-08:09 | 0.204758E+10 | 1435.25 | 02-JAN-08:09 |
February | 0.735043E+09 | 1358.45 | 01-FEB-08:09 | 0.185366E+10 | 1435.25 | 01-FEB-08:09 |
March | 0.796382E+09 | 1184.79 | 15-MAR-07:10 | 0.212947E+10 | 1435.25 | 01-MAR-08:09 |
April | 0.656956E+09 | 1184.79 | 10-APR-07:10 | 0.197726E+10 | 1435.25 | 03-APR-07:10 |
May | 0.684826E+09 | 711.15 | 03-MAY-07:10 | 0.208852E+10 | 1435.25 | 01-MAY-07:10 |
June | 0.672939E+09 | 647.98 | 01-JUN-07:10 | 0.205071E+10 | 1435.25 | 01-JUN-07:10 |
July | 0.631299E+09 | 711.15 | 07-JUL-07:10 | 0.201461E+10 | 1435.25 | 03-JUL-07:10 |
August | 0.724853E+09 | 947.97 | 22-AUG-07:19 | 0.212947E+10 | 1435.25 | 01-AUG-07:10 |
September | 0.679094E+09 | 947.97 | 08-SEP-07:10 | 0.197634E+10 | 1435.25 | 01-SEP-07:10 |
October | 0.796375E+09 | 1358.45 | 16-OCT-07:10 | 0.204804E+10 | 1435.25 | 02-OCT-07:10 |
November | 0.901323E+09 | 1358.45 | 01-NOV-07:10 | 0.200273E+10 | 1435.25 | 01-NOV-07:10 |
December | 0.954979E+09 | 1358.45 | 01-DEC-08:09 | 0.201415E+10 | 1435.25 | 01-DEC-08:09 |
Annual Sum or Average | 0.914659E+10 | 0.243325E+11 | ||||
Minimum of Months | 0.631299E+09 | 647.98 | 0.185366E+10 | 1435.25 | ||
Maximum of Months | 0.954979E+09 | 1358.45 | 0.212947E+10 | 1435.25 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.551081E+09 | 860.01 | 02-JAN-08:09 | 0.129621E+10 | 908.57 | 02-JAN-08:09 |
February | 0.450959E+09 | 860.01 | 01-FEB-08:09 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.497427E+09 | 750.07 | 15-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.415425E+09 | 600.14 | 10-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.435783E+09 | 450.21 | 15-MAY-15:09 | 0.132213E+10 | 908.57 | 01-MAY-07:10 |
June | 0.428746E+09 | 410.22 | 01-JUN-07:10 | 0.129819E+10 | 908.57 | 01-JUN-07:10 |
July | 0.402118E+09 | 450.21 | 07-JUL-15:30 | 0.127534E+10 | 908.57 | 03-JUL-07:10 |
August | 0.459102E+09 | 490.21 | 22-AUG-07:30 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.425039E+09 | 600.14 | 08-SEP-07:30 | 0.125111E+10 | 908.57 | 01-SEP-07:10 |
October | 0.492583E+09 | 860.01 | 16-OCT-07:10 | 0.129650E+10 | 908.57 | 02-OCT-07:10 |
November | 0.550318E+09 | 860.01 | 01-NOV-07:10 | 0.126781E+10 | 908.57 | 01-NOV-07:10 |
December | 0.573567E+09 | 860.01 | 01-DEC-08:09 | 0.127504E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.568215E+10 | 0.154036E+11 | ||||
Minimum of Months | 0.402118E+09 | 410.22 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.573567E+09 | 860.01 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.847701E+09 | 1358.45 | 02-JAN-08:09 | 0.204757E+10 | 1435.24 | 02-JAN-08:09 |
February | 0.697594E+09 | 1358.45 | 01-FEB-08:09 | 0.185364E+10 | 1435.24 | 01-FEB-08:09 |
March | 0.779045E+09 | 1184.79 | 15-MAR-07:10 | 0.212945E+10 | 1435.24 | 01-MAR-08:09 |
April | 0.657866E+09 | 1184.79 | 10-APR-07:10 | 0.197725E+10 | 1435.24 | 03-APR-07:10 |
May | 0.688318E+09 | 711.15 | 03-MAY-07:10 | 0.208851E+10 | 1435.24 | 01-MAY-07:10 |
June | 0.677102E+09 | 647.98 | 01-JUN-07:10 | 0.205070E+10 | 1435.24 | 01-JUN-07:10 |
July | 0.635638E+09 | 711.15 | 07-JUL-07:10 | 0.201460E+10 | 1435.24 | 03-JUL-07:10 |
August | 0.728067E+09 | 947.97 | 22-AUG-07:19 | 0.212945E+10 | 1435.24 | 01-AUG-07:10 |
September | 0.673715E+09 | 947.97 | 08-SEP-07:10 | 0.197632E+10 | 1435.24 | 01-SEP-07:10 |
October | 0.767074E+09 | 1358.45 | 16-OCT-07:10 | 0.204803E+10 | 1435.24 | 02-OCT-07:10 |
November | 0.845518E+09 | 1358.45 | 01-NOV-07:10 | 0.200271E+10 | 1435.24 | 01-NOV-07:10 |
December | 0.881787E+09 | 1358.45 | 01-DEC-08:09 | 0.201413E+10 | 1435.24 | 01-DEC-08:09 |
Annual Sum or Average | 0.887943E+10 | 0.243324E+11 | ||||
Minimum of Months | 0.635638E+09 | 647.98 | 0.185364E+10 | 1435.24 | ||
Maximum of Months | 0.881787E+09 | 1358.45 | 0.212945E+10 | 1435.24 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.557808E+09 | 859.95 | 02-JAN-08:09 | 0.129620E+10 | 908.57 | 02-JAN-08:09 |
February | 0.454445E+09 | 859.95 | 01-FEB-08:09 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.500499E+09 | 859.95 | 15-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.417038E+09 | 750.02 | 10-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.434760E+09 | 490.17 | 03-MAY-07:10 | 0.132212E+10 | 908.57 | 01-MAY-07:10 |
June | 0.426937E+09 | 450.19 | 05-JUN-07:10 | 0.129818E+10 | 908.57 | 01-JUN-07:10 |
July | 0.400733E+09 | 450.19 | 07-JUL-07:10 | 0.127533E+10 | 908.57 | 03-JUL-07:10 |
August | 0.461275E+09 | 600.10 | 22-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.430564E+09 | 750.02 | 08-SEP-07:10 | 0.125110E+10 | 908.57 | 01-SEP-07:10 |
October | 0.496722E+09 | 859.95 | 16-OCT-07:10 | 0.129649E+10 | 908.57 | 02-OCT-07:10 |
November | 0.552708E+09 | 859.95 | 01-NOV-07:10 | 0.126780E+10 | 908.57 | 01-NOV-07:10 |
December | 0.584249E+09 | 859.95 | 01-DEC-08:09 | 0.127503E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.571774E+10 | 0.154035E+11 | ||||
Minimum of Months | 0.400733E+09 | 450.19 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.584249E+09 | 859.95 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.907036E+09 | 1358.45 | 02-JAN-08:09 | 0.204758E+10 | 1435.25 | 02-JAN-08:09 |
February | 0.731145E+09 | 1358.45 | 01-FEB-08:09 | 0.185366E+10 | 1435.25 | 01-FEB-08:09 |
March | 0.792412E+09 | 1184.79 | 15-MAR-07:10 | 0.212947E+10 | 1435.25 | 01-MAR-08:09 |
April | 0.656294E+09 | 1184.79 | 10-APR-07:10 | 0.197726E+10 | 1435.25 | 03-APR-07:10 |
May | 0.684273E+09 | 711.15 | 03-MAY-07:10 | 0.208852E+10 | 1435.25 | 01-MAY-07:10 |
June | 0.672611E+09 | 647.98 | 01-JUN-07:10 | 0.205071E+10 | 1435.25 | 01-JUN-07:10 |
July | 0.630876E+09 | 711.15 | 07-JUL-07:10 | 0.201461E+10 | 1435.25 | 03-JUL-07:10 |
August | 0.723825E+09 | 947.97 | 22-AUG-07:30 | 0.212947E+10 | 1435.25 | 01-AUG-07:10 |
September | 0.677348E+09 | 947.97 | 08-SEP-07:10 | 0.197634E+10 | 1435.25 | 01-SEP-07:10 |
October | 0.792307E+09 | 1358.45 | 16-OCT-07:10 | 0.204804E+10 | 1435.25 | 02-OCT-07:10 |
November | 0.894818E+09 | 1358.45 | 01-NOV-07:10 | 0.200273E+10 | 1435.25 | 01-NOV-07:10 |
December | 0.948657E+09 | 1358.45 | 01-DEC-08:09 | 0.201415E+10 | 1435.25 | 01-DEC-08:09 |
Annual Sum or Average | 0.911160E+10 | 0.243325E+11 | ||||
Minimum of Months | 0.630876E+09 | 647.98 | 0.185366E+10 | 1435.25 | ||
Maximum of Months | 0.948657E+09 | 1358.45 | 0.212947E+10 | 1435.25 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.548797E+09 | 860.01 | 02-JAN-08:09 | 0.129621E+10 | 908.57 | 02-JAN-08:09 |
February | 0.449394E+09 | 860.01 | 01-FEB-08:09 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.496005E+09 | 750.07 | 15-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.414837E+09 | 600.14 | 10-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.435430E+09 | 450.21 | 15-MAY-15:09 | 0.132213E+10 | 908.57 | 01-MAY-07:10 |
June | 0.428460E+09 | 410.22 | 01-JUN-07:10 | 0.129819E+10 | 908.57 | 01-JUN-07:10 |
July | 0.401814E+09 | 450.21 | 07-JUL-15:30 | 0.127534E+10 | 908.57 | 03-JUL-07:10 |
August | 0.458486E+09 | 490.21 | 22-AUG-07:30 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.424438E+09 | 600.14 | 08-SEP-07:30 | 0.125111E+10 | 908.57 | 01-SEP-07:10 |
October | 0.490362E+09 | 860.01 | 16-OCT-07:10 | 0.129650E+10 | 908.57 | 02-OCT-07:10 |
November | 0.546594E+09 | 860.01 | 01-NOV-07:10 | 0.126781E+10 | 908.57 | 01-NOV-07:10 |
December | 0.571031E+09 | 860.01 | 01-DEC-08:09 | 0.127504E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.566565E+10 | 0.154036E+11 | ||||
Minimum of Months | 0.401814E+09 | 410.22 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.571031E+09 | 860.01 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.844936E+09 | 1358.45 | 02-JAN-08:09 | 0.204757E+10 | 1435.24 | 02-JAN-08:09 |
February | 0.695925E+09 | 1358.45 | 01-FEB-08:09 | 0.185364E+10 | 1435.24 | 01-FEB-08:09 |
March | 0.777373E+09 | 1184.79 | 15-MAR-07:10 | 0.212945E+10 | 1435.24 | 01-MAR-08:09 |
April | 0.657207E+09 | 1184.79 | 10-APR-07:10 | 0.197725E+10 | 1435.24 | 03-APR-07:10 |
May | 0.687849E+09 | 711.15 | 03-MAY-07:10 | 0.208851E+10 | 1435.24 | 01-MAY-07:10 |
June | 0.676246E+09 | 647.98 | 01-JUN-07:10 | 0.205070E+10 | 1435.24 | 01-JUN-07:10 |
July | 0.635016E+09 | 711.15 | 07-JUL-07:10 | 0.201460E+10 | 1435.24 | 03-JUL-07:10 |
August | 0.726922E+09 | 947.97 | 22-AUG-07:30 | 0.212945E+10 | 1435.24 | 01-AUG-07:10 |
September | 0.672639E+09 | 947.97 | 08-SEP-07:19 | 0.197632E+10 | 1435.24 | 01-SEP-07:10 |
October | 0.765293E+09 | 1358.45 | 16-OCT-07:10 | 0.204803E+10 | 1435.24 | 02-OCT-07:10 |
November | 0.842071E+09 | 1358.45 | 01-NOV-07:10 | 0.200271E+10 | 1435.24 | 01-NOV-07:10 |
December | 0.879126E+09 | 1358.45 | 01-DEC-08:09 | 0.201413E+10 | 1435.24 | 01-DEC-08:09 |
Annual Sum or Average | 0.886060E+10 | 0.243324E+11 | ||||
Minimum of Months | 0.635016E+09 | 647.98 | 0.185364E+10 | 1435.24 | ||
Maximum of Months | 0.879126E+09 | 1358.45 | 0.212945E+10 | 1435.24 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.555163E+09 | 859.95 | 02-JAN-08:09 | 0.129620E+10 | 908.57 | 02-JAN-08:09 |
February | 0.452450E+09 | 859.95 | 01-FEB-08:09 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.499225E+09 | 859.95 | 15-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.416032E+09 | 750.02 | 10-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.434277E+09 | 490.17 | 04-MAY-07:10 | 0.132212E+10 | 908.57 | 01-MAY-07:10 |
June | 0.426545E+09 | 450.19 | 14-JUN-07:10 | 0.129818E+10 | 908.57 | 01-JUN-07:10 |
July | 0.400419E+09 | 450.19 | 07-JUL-07:10 | 0.127533E+10 | 908.57 | 03-JUL-07:10 |
August | 0.460635E+09 | 600.10 | 22-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.429450E+09 | 750.02 | 08-SEP-07:10 | 0.125110E+10 | 908.57 | 01-SEP-07:10 |
October | 0.495165E+09 | 859.95 | 16-OCT-07:10 | 0.129649E+10 | 908.57 | 02-OCT-07:10 |
November | 0.549987E+09 | 859.95 | 01-NOV-07:10 | 0.126780E+10 | 908.57 | 01-NOV-07:10 |
December | 0.581106E+09 | 859.95 | 01-DEC-08:09 | 0.127503E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.570045E+10 | 0.154035E+11 | ||||
Minimum of Months | 0.400419E+09 | 450.19 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.581106E+09 | 859.95 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.912524E+09 | 1358.45 | 02-JAN-08:09 | 0.204758E+10 | 1435.25 | 02-JAN-08:09 |
February | 0.735043E+09 | 1358.45 | 01-FEB-08:09 | 0.185366E+10 | 1435.25 | 01-FEB-08:09 |
March | 0.796344E+09 | 1184.79 | 15-MAR-07:10 | 0.212947E+10 | 1435.25 | 01-MAR-08:09 |
April | 0.656956E+09 | 1184.79 | 10-APR-07:10 | 0.197726E+10 | 1435.25 | 03-APR-07:10 |
May | 0.684826E+09 | 711.15 | 03-MAY-07:10 | 0.208852E+10 | 1435.25 | 01-MAY-07:10 |
June | 0.672939E+09 | 647.98 | 01-JUN-07:10 | 0.205071E+10 | 1435.25 | 01-JUN-07:10 |
July | 0.631299E+09 | 711.15 | 07-JUL-07:10 | 0.201461E+10 | 1435.25 | 03-JUL-07:10 |
August | 0.724853E+09 | 947.97 | 22-AUG-07:19 | 0.212947E+10 | 1435.25 | 01-AUG-07:10 |
September | 0.679094E+09 | 947.97 | 08-SEP-07:10 | 0.197634E+10 | 1435.25 | 01-SEP-07:10 |
October | 0.796375E+09 | 1358.45 | 16-OCT-07:10 | 0.204804E+10 | 1435.25 | 02-OCT-07:10 |
November | 0.901219E+09 | 1358.45 | 01-NOV-07:10 | 0.200273E+10 | 1435.25 | 01-NOV-07:10 |
December | 0.954979E+09 | 1358.45 | 01-DEC-08:09 | 0.201415E+10 | 1435.25 | 01-DEC-08:09 |
Annual Sum or Average | 0.914645E+10 | 0.243325E+11 | ||||
Minimum of Months | 0.631299E+09 | 647.98 | 0.185366E+10 | 1435.25 | ||
Maximum of Months | 0.954979E+09 | 1358.45 | 0.212947E+10 | 1435.25 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.551081E+09 | 860.01 | 02-JAN-08:09 | 0.129621E+10 | 908.57 | 02-JAN-08:09 |
February | 0.450959E+09 | 860.01 | 01-FEB-08:09 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.497427E+09 | 750.07 | 15-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.415425E+09 | 600.14 | 10-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.435783E+09 | 450.21 | 15-MAY-15:09 | 0.132213E+10 | 908.57 | 01-MAY-07:10 |
June | 0.428746E+09 | 410.22 | 01-JUN-07:10 | 0.129819E+10 | 908.57 | 01-JUN-07:10 |
July | 0.402118E+09 | 450.21 | 07-JUL-15:30 | 0.127534E+10 | 908.57 | 03-JUL-07:10 |
August | 0.459102E+09 | 490.21 | 22-AUG-07:30 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.425039E+09 | 600.14 | 08-SEP-07:30 | 0.125111E+10 | 908.57 | 01-SEP-07:10 |
October | 0.492583E+09 | 860.01 | 16-OCT-07:10 | 0.129650E+10 | 908.57 | 02-OCT-07:10 |
November | 0.550318E+09 | 860.01 | 01-NOV-07:10 | 0.126781E+10 | 908.57 | 01-NOV-07:10 |
December | 0.573543E+09 | 860.01 | 01-DEC-08:09 | 0.127504E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.568212E+10 | 0.154036E+11 | ||||
Minimum of Months | 0.402118E+09 | 410.22 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.573543E+09 | 860.01 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.847701E+09 | 1358.45 | 02-JAN-08:09 | 0.204757E+10 | 1435.24 | 02-JAN-08:09 |
February | 0.697594E+09 | 1358.45 | 01-FEB-08:09 | 0.185364E+10 | 1435.24 | 01-FEB-08:09 |
March | 0.779045E+09 | 1184.79 | 15-MAR-07:10 | 0.212945E+10 | 1435.24 | 01-MAR-08:09 |
April | 0.657866E+09 | 1184.79 | 10-APR-07:10 | 0.197725E+10 | 1435.24 | 03-APR-07:10 |
May | 0.688318E+09 | 711.15 | 03-MAY-07:10 | 0.208851E+10 | 1435.24 | 01-MAY-07:10 |
June | 0.677102E+09 | 647.98 | 01-JUN-07:10 | 0.205070E+10 | 1435.24 | 01-JUN-07:10 |
July | 0.635638E+09 | 711.15 | 07-JUL-07:10 | 0.201460E+10 | 1435.24 | 03-JUL-07:10 |
August | 0.728067E+09 | 947.97 | 22-AUG-07:19 | 0.212945E+10 | 1435.24 | 01-AUG-07:10 |
September | 0.673715E+09 | 947.97 | 08-SEP-07:10 | 0.197632E+10 | 1435.24 | 01-SEP-07:10 |
October | 0.767074E+09 | 1358.45 | 16-OCT-07:10 | 0.204803E+10 | 1435.24 | 02-OCT-07:10 |
November | 0.845518E+09 | 1358.45 | 01-NOV-07:10 | 0.200271E+10 | 1435.24 | 01-NOV-07:10 |
December | 0.881787E+09 | 1358.45 | 01-DEC-08:09 | 0.201413E+10 | 1435.24 | 01-DEC-08:09 |
Annual Sum or Average | 0.887943E+10 | 0.243324E+11 | ||||
Minimum of Months | 0.635638E+09 | 647.98 | 0.185364E+10 | 1435.24 | ||
Maximum of Months | 0.881787E+09 | 1358.45 | 0.212945E+10 | 1435.24 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.557808E+09 | 859.95 | 02-JAN-08:09 | 0.129620E+10 | 908.57 | 02-JAN-08:09 |
February | 0.454437E+09 | 859.95 | 01-FEB-08:09 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.500499E+09 | 859.95 | 15-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.417038E+09 | 750.02 | 10-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.434760E+09 | 490.17 | 03-MAY-07:10 | 0.132212E+10 | 908.57 | 01-MAY-07:10 |
June | 0.426937E+09 | 450.19 | 05-JUN-07:10 | 0.129818E+10 | 908.57 | 01-JUN-07:10 |
July | 0.400733E+09 | 450.19 | 07-JUL-07:10 | 0.127533E+10 | 908.57 | 03-JUL-07:10 |
August | 0.461275E+09 | 600.10 | 22-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.430564E+09 | 750.02 | 08-SEP-07:10 | 0.125110E+10 | 908.57 | 01-SEP-07:10 |
October | 0.496722E+09 | 859.95 | 16-OCT-07:10 | 0.129649E+10 | 908.57 | 02-OCT-07:10 |
November | 0.552704E+09 | 859.95 | 01-NOV-07:10 | 0.126780E+10 | 908.57 | 01-NOV-07:10 |
December | 0.584117E+09 | 859.95 | 01-DEC-08:09 | 0.127503E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.571759E+10 | 0.154035E+11 | ||||
Minimum of Months | 0.400733E+09 | 450.19 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.584117E+09 | 859.95 | 0.134804E+10 | 908.57 |
Report: SpaceGainsMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.599791E+10 | 0.210964E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.544142E+10 | 0.191215E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.648083E+10 | 0.217104E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.577357E+10 | 0.204846E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.623937E+10 | 0.214034E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.621476E+10 | 0.209475E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.579818E+10 | 0.209382E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.648074E+10 | 0.217104E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.577357E+10 | 0.204802E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.599800E+10 | 0.210986E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.593174E+10 | 0.204961E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.579827E+10 | 0.209360E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.719283E+11 | 0.250423E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.544142E+10 | 0.191215E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.648083E+10 | 0.217104E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.599791E+10 | 0.971303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.544142E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.648083E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.577357E+10 | 0.937947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.623937E+10 | 0.990724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.621476E+10 | 0.972788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.579818E+10 | 0.955663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.648074E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.577357E+10 | 0.937507E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.599800E+10 | 0.971523E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.593174E+10 | 0.950025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.579827E+10 | 0.955443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.719283E+11 | 0.115425E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.544142E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.648083E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.599791E+10 | 0.971303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.544142E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.648083E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.577357E+10 | 0.937947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.623937E+10 | 0.990724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.621476E+10 | 0.972788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.579818E+10 | 0.955663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.648074E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.577357E+10 | 0.937507E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.599800E+10 | 0.971523E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.593174E+10 | 0.950025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.579827E+10 | 0.955443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.719283E+11 | 0.115425E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.544142E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.648083E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.912524E+09 | 0.204758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102681E+09 |
February | 0.901968E+09 | 0.735043E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.147380E+09 |
March | 0.107774E+10 | 0.796382E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87932048.33 |
April | 0.956342E+09 | 0.656956E+09 | 0.197726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117383E+09 |
May | 0.103597E+10 | 0.684826E+09 | 0.208852E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.289795E+09 |
June | 0.103308E+10 | 0.672939E+09 | 0.205071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 139646.96 | 0.228608E+09 |
July | 0.959235E+09 | 0.631299E+09 | 0.201461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 663271.82 | 0.218071E+09 |
August | 0.107774E+10 | 0.724853E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 90872.72 | 0.155668E+09 |
September | 0.956342E+09 | 0.679094E+09 | 0.197634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.158303E+09 |
October | 0.994195E+09 | 0.796375E+09 | 0.204804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159789E+09 |
November | 0.984487E+09 | 0.901323E+09 | 0.200273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.190560E+09 |
December | 0.959235E+09 | 0.954979E+09 | 0.201415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.257542E+09 |
Annual Sum or Average | 0.119305E+11 | 0.914659E+10 | 0.243325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 893791.50 | 0.211371E+10 |
Minimum of Months | 0.901968E+09 | 0.631299E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87932048.33 |
Maximum of Months | 0.107774E+10 | 0.954979E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 663271.82 | 0.289795E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629407E+09 | 0.551081E+09 | 0.129621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69146216.89 |
February | 0.571020E+09 | 0.450959E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 99398539.58 |
March | 0.682301E+09 | 0.497427E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59089977.69 |
April | 0.605444E+09 | 0.415425E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 81280208.33 |
May | 0.655854E+09 | 0.435783E+09 | 0.132213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.197224E+09 |
June | 0.654023E+09 | 0.428746E+09 | 0.129819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 93099.44 | 0.154037E+09 |
July | 0.607275E+09 | 0.402118E+09 | 0.127534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 476381.22 | 0.149076E+09 |
August | 0.682301E+09 | 0.459102E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60582.94 | 0.106661E+09 |
September | 0.605444E+09 | 0.425039E+09 | 0.125111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110571E+09 |
October | 0.629407E+09 | 0.492583E+09 | 0.129650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108356E+09 |
November | 0.623262E+09 | 0.550318E+09 | 0.126781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.127784E+09 |
December | 0.607275E+09 | 0.573567E+09 | 0.127504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.171988E+09 |
Annual Sum or Average | 0.755301E+10 | 0.568215E+10 | 0.154036E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 630063.60 | 0.143461E+10 |
Minimum of Months | 0.571020E+09 | 0.402118E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59089977.69 |
Maximum of Months | 0.682301E+09 | 0.573567E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 476381.22 | 0.197224E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.847701E+09 | 0.204757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109034E+09 |
February | 0.901968E+09 | 0.697594E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156029E+09 |
March | 0.107774E+10 | 0.779045E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90546236.75 |
April | 0.956342E+09 | 0.657866E+09 | 0.197725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124077E+09 |
May | 0.103597E+10 | 0.688318E+09 | 0.208851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.296570E+09 |
June | 0.103308E+10 | 0.677102E+09 | 0.205070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 139642.43 | 0.230279E+09 |
July | 0.959235E+09 | 0.635638E+09 | 0.201460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 694183.13 | 0.223369E+09 |
August | 0.107774E+10 | 0.728067E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 90871.87 | 0.162536E+09 |
September | 0.956342E+09 | 0.673715E+09 | 0.197632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.170422E+09 |
October | 0.994195E+09 | 0.767074E+09 | 0.204803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.170487E+09 |
November | 0.984487E+09 | 0.845518E+09 | 0.200271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.199675E+09 |
December | 0.959235E+09 | 0.881787E+09 | 0.201413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.265324E+09 |
Annual Sum or Average | 0.119305E+11 | 0.887943E+10 | 0.243324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 924697.42 | 0.219835E+10 |
Minimum of Months | 0.901968E+09 | 0.635638E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90546236.75 |
Maximum of Months | 0.107774E+10 | 0.881787E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 694183.13 | 0.296570E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.557808E+09 | 0.129620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69047155.24 |
February | 0.570983E+09 | 0.454445E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 99954390.56 |
March | 0.682256E+09 | 0.500499E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58727749.53 |
April | 0.605404E+09 | 0.417038E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80088612.53 |
May | 0.655811E+09 | 0.434760E+09 | 0.132212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.198950E+09 |
June | 0.653980E+09 | 0.426937E+09 | 0.129818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 93095.74 | 0.156469E+09 |
July | 0.607235E+09 | 0.400733E+09 | 0.127533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 389899.42 | 0.151379E+09 |
August | 0.682256E+09 | 0.461275E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60585.93 | 0.107825E+09 |
September | 0.605404E+09 | 0.430564E+09 | 0.125110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108757E+09 |
October | 0.629366E+09 | 0.496722E+09 | 0.129649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108490E+09 |
November | 0.623221E+09 | 0.552708E+09 | 0.126780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.127700E+09 |
December | 0.607235E+09 | 0.584249E+09 | 0.127503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.171556E+09 |
Annual Sum or Average | 0.755252E+10 | 0.571774E+10 | 0.154035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 543581.09 | 0.143894E+10 |
Minimum of Months | 0.570983E+09 | 0.400733E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58727749.53 |
Maximum of Months | 0.682256E+09 | 0.584249E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 389899.42 | 0.198950E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.907036E+09 | 0.204758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58052688.11 |
February | 0.901968E+09 | 0.731145E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83391237.31 |
March | 0.107774E+10 | 0.792412E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48404231.82 |
April | 0.956342E+09 | 0.656294E+09 | 0.197726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8302.35 | 62928986.30 |
May | 0.103597E+10 | 0.684273E+09 | 0.208852E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.22 | 0.157287E+09 |
June | 0.103308E+10 | 0.672611E+09 | 0.205071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 77367.78 | 0.123522E+09 |
July | 0.959235E+09 | 0.630876E+09 | 0.201461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 401012.06 | 0.118049E+09 |
August | 0.107774E+10 | 0.723825E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49989.64 | 84222198.89 |
September | 0.956342E+09 | 0.677348E+09 | 0.197634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88756553.97 |
October | 0.994195E+09 | 0.792307E+09 | 0.204804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 92068065.81 |
November | 0.984487E+09 | 0.894818E+09 | 0.200273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111417E+09 |
December | 0.959235E+09 | 0.948657E+09 | 0.201415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149960E+09 |
Annual Sum or Average | 0.119305E+11 | 0.911160E+10 | 0.243325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 536673.05 | 0.117806E+10 |
Minimum of Months | 0.901968E+09 | 0.630876E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48404231.82 |
Maximum of Months | 0.107774E+10 | 0.948657E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 401012.06 | 0.157287E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629407E+09 | 0.548797E+09 | 0.129621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39254071.18 |
February | 0.571020E+09 | 0.449394E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56484857.88 |
March | 0.682301E+09 | 0.496005E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32660420.82 |
April | 0.605444E+09 | 0.414837E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45094702.52 |
May | 0.655854E+09 | 0.435430E+09 | 0.132213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.80 | 0.110683E+09 |
June | 0.654023E+09 | 0.428460E+09 | 0.129819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51132.90 | 85478170.06 |
July | 0.607275E+09 | 0.401814E+09 | 0.127534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 258512.23 | 83373227.14 |
August | 0.682301E+09 | 0.458486E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33159.70 | 60142635.69 |
September | 0.605444E+09 | 0.424438E+09 | 0.125111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63914233.08 |
October | 0.629407E+09 | 0.490362E+09 | 0.129650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63317676.93 |
November | 0.623262E+09 | 0.546594E+09 | 0.126781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74951729.59 |
December | 0.607275E+09 | 0.571031E+09 | 0.127504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100088E+09 |
Annual Sum or Average | 0.755301E+10 | 0.566565E+10 | 0.154036E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 342805.63 | 0.815443E+09 |
Minimum of Months | 0.571020E+09 | 0.401814E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32660420.82 |
Maximum of Months | 0.682301E+09 | 0.571031E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 258512.23 | 0.110683E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.844936E+09 | 0.204757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.421990E+10 |
February | 0.901968E+09 | 0.695925E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.366134E+10 |
March | 0.107774E+10 | 0.777373E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.403496E+10 |
April | 0.956342E+09 | 0.657207E+09 | 0.197725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.301050E+10 |
May | 0.103597E+10 | 0.687849E+09 | 0.208851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 81.79 | 0.314131E+10 |
June | 0.103308E+10 | 0.676246E+09 | 0.205070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12548951.46 | 0.225192E+10 |
July | 0.959235E+09 | 0.635016E+09 | 0.201460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21193545.65 | 0.171716E+10 |
August | 0.107774E+10 | 0.726922E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9431587.47 | 0.177067E+10 |
September | 0.956342E+09 | 0.672639E+09 | 0.197632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.209227E+10 |
October | 0.994195E+09 | 0.765293E+09 | 0.204803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.305896E+10 |
November | 0.984487E+09 | 0.842071E+09 | 0.200271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.367471E+10 |
December | 0.959235E+09 | 0.879126E+09 | 0.201413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.399003E+10 |
Annual Sum or Average | 0.119305E+11 | 0.886060E+10 | 0.243324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 43174166.37 | 0.366237E+11 |
Minimum of Months | 0.901968E+09 | 0.635016E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.171716E+10 |
Maximum of Months | 0.107774E+10 | 0.879126E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21193545.65 | 0.421990E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.555163E+09 | 0.129620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39108911.29 |
February | 0.570983E+09 | 0.452450E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56832629.78 |
March | 0.682256E+09 | 0.499225E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32376483.71 |
April | 0.605404E+09 | 0.416032E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44408798.85 |
May | 0.655811E+09 | 0.434277E+09 | 0.132212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.82 | 0.111398E+09 |
June | 0.653980E+09 | 0.426545E+09 | 0.129818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51133.59 | 87418524.96 |
July | 0.607235E+09 | 0.400419E+09 | 0.127533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 209362.21 | 84642969.84 |
August | 0.682256E+09 | 0.460635E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33161.82 | 60810655.83 |
September | 0.605404E+09 | 0.429450E+09 | 0.125110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62750792.94 |
October | 0.629366E+09 | 0.495165E+09 | 0.129649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63071529.25 |
November | 0.623221E+09 | 0.549987E+09 | 0.126780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74695959.95 |
December | 0.607235E+09 | 0.581106E+09 | 0.127503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 99722321.21 |
Annual Sum or Average | 0.755252E+10 | 0.570045E+10 | 0.154035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 293658.44 | 0.817238E+09 |
Minimum of Months | 0.570983E+09 | 0.400419E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32376483.71 |
Maximum of Months | 0.682256E+09 | 0.581106E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 209362.21 | 0.111398E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.912524E+09 | 0.204758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91157693.89 |
February | 0.901968E+09 | 0.735043E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131789E+09 |
March | 0.107774E+10 | 0.796344E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77519337.16 |
April | 0.956342E+09 | 0.656956E+09 | 0.197726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103089E+09 |
May | 0.103597E+10 | 0.684826E+09 | 0.208852E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.253800E+09 |
June | 0.103308E+10 | 0.672939E+09 | 0.205071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 118152.56 | 0.197738E+09 |
July | 0.959235E+09 | 0.631299E+09 | 0.201461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 581650.02 | 0.188730E+09 |
August | 0.107774E+10 | 0.724853E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 76743.04 | 0.135560E+09 |
September | 0.956342E+09 | 0.679094E+09 | 0.197634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140946E+09 |
October | 0.994195E+09 | 0.796375E+09 | 0.204804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144358E+09 |
November | 0.984487E+09 | 0.901219E+09 | 0.200273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.172076E+09 |
December | 0.959235E+09 | 0.954979E+09 | 0.201415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.231310E+09 |
Annual Sum or Average | 0.119305E+11 | 0.914645E+10 | 0.243325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 776545.62 | 0.186807E+10 |
Minimum of Months | 0.901968E+09 | 0.631299E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77519337.16 |
Maximum of Months | 0.107774E+10 | 0.954979E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 581650.02 | 0.253800E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.465148E+09 | 0.551081E+09 | 0.129621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61311138.42 |
February | 0.421807E+09 | 0.450959E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88631863.49 |
March | 0.502994E+09 | 0.497427E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51811210.51 |
April | 0.447140E+09 | 0.415425E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70634496.22 |
May | 0.484071E+09 | 0.435783E+09 | 0.132213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.171402E+09 |
June | 0.482240E+09 | 0.428746E+09 | 0.129819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 78766.25 | 0.132599E+09 |
July | 0.448971E+09 | 0.402118E+09 | 0.127534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 418106.81 | 0.128087E+09 |
August | 0.502994E+09 | 0.459102E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51161.81 | 92170739.45 |
September | 0.447140E+09 | 0.425039E+09 | 0.125111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97168167.28 |
October | 0.465148E+09 | 0.492583E+09 | 0.129650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97044789.22 |
November | 0.460569E+09 | 0.550318E+09 | 0.126781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115005E+09 |
December | 0.448971E+09 | 0.573543E+09 | 0.127504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154303E+09 |
Annual Sum or Average | 0.557719E+10 | 0.568212E+10 | 0.154036E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 548034.87 | 0.126017E+10 |
Minimum of Months | 0.421807E+09 | 0.402118E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51811210.51 |
Maximum of Months | 0.502994E+09 | 0.573543E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 418106.81 | 0.171402E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.847701E+09 | 0.204757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96843517.41 |
February | 0.901968E+09 | 0.697594E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.138935E+09 |
March | 0.107774E+10 | 0.779045E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 79690786.34 |
April | 0.956342E+09 | 0.657866E+09 | 0.197725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108086E+09 |
May | 0.103597E+10 | 0.688318E+09 | 0.208851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.258846E+09 |
June | 0.103308E+10 | 0.677102E+09 | 0.205070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 118148.61 | 0.199381E+09 |
July | 0.959235E+09 | 0.635638E+09 | 0.201460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 596528.42 | 0.193160E+09 |
August | 0.107774E+10 | 0.728067E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 76741.63 | 0.141416E+09 |
September | 0.956342E+09 | 0.673715E+09 | 0.197632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150012E+09 |
October | 0.994195E+09 | 0.767074E+09 | 0.204803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.152393E+09 |
November | 0.984487E+09 | 0.845518E+09 | 0.200271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.179722E+09 |
December | 0.959235E+09 | 0.881787E+09 | 0.201413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238074E+09 |
Annual Sum or Average | 0.119305E+11 | 0.887943E+10 | 0.243324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 791418.66 | 0.193656E+10 |
Minimum of Months | 0.901968E+09 | 0.635638E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 79690786.34 |
Maximum of Months | 0.107774E+10 | 0.881787E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 596528.42 | 0.258846E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.557808E+09 | 0.129620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61247504.36 |
February | 0.570983E+09 | 0.454437E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89110945.82 |
March | 0.682256E+09 | 0.500499E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51633892.88 |
April | 0.605404E+09 | 0.417038E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70118886.47 |
May | 0.655811E+09 | 0.434760E+09 | 0.132212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.173715E+09 |
June | 0.653980E+09 | 0.426937E+09 | 0.129818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 78765.46 | 0.135468E+09 |
July | 0.607235E+09 | 0.400733E+09 | 0.127533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 322575.30 | 0.130953E+09 |
August | 0.682256E+09 | 0.461275E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51165.22 | 93962602.07 |
September | 0.605404E+09 | 0.430564E+09 | 0.125110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96488599.95 |
October | 0.629366E+09 | 0.496722E+09 | 0.129649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 97406029.37 |
November | 0.623221E+09 | 0.552704E+09 | 0.126780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114953E+09 |
December | 0.607235E+09 | 0.584117E+09 | 0.127503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.153957E+09 |
Annual Sum or Average | 0.755252E+10 | 0.571759E+10 | 0.154035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 452505.98 | 0.126901E+10 |
Minimum of Months | 0.570983E+09 | 0.400733E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51633892.88 |
Maximum of Months | 0.682256E+09 | 0.584117E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 322575.30 | 0.173715E+09 |
Report: SpaceGainsMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128288E+09 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.186862E+09 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107388E+09 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141999E+09 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.349102E+09 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82926.38 | 0.269111E+09 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 587253.91 | 0.259594E+09 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58492.46 | 0.190181E+09 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200526E+09 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206829E+09 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.247994E+09 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.330137E+09 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 728672.75 | 0.261801E+10 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107388E+09 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 587253.91 | 0.349102E+09 |
Report: SpaceGainsMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.155348E+09 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.227010E+09 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131379E+09 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.177111E+09 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.437805E+09 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 107609.03 | 0.339807E+09 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 786017.23 | 0.326102E+09 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77720.07 | 0.238746E+09 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.247837E+09 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.250656E+09 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.298183E+09 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.397275E+09 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 971346.33 | 0.322726E+10 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131379E+09 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 786017.23 | 0.437805E+09 |
Report: SpaceGainsMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156529E+09 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.226024E+09 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135770E+09 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.187965E+09 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.454335E+09 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39174.86 | 0.358053E+09 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 492454.51 | 0.344787E+09 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42536.65 | 0.247323E+09 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.250836E+09 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.247039E+09 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.289163E+09 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.388147E+09 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 574166.02 | 0.328597E+10 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135770E+09 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 492454.51 | 0.454335E+09 |
Report: PeakSpaceGainsMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 6443.98 | 02-JAN-08:09 | 14019.75 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 6443.98 | 01-FEB-08:09 | 14019.75 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 6443.98 | 01-MAR-08:09 | 14019.75 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 6443.98 | 03-APR-07:10 | 14019.75 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 6443.98 | 01-MAY-07:10 | 14019.75 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 6443.98 | 01-JUN-07:10 | 14019.75 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 6443.98 | 03-JUL-07:10 | 14019.75 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 6443.98 | 01-AUG-07:10 | 14019.75 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 6443.98 | 01-SEP-07:10 | 14019.75 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 6443.98 | 02-OCT-07:10 | 14019.75 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 6443.98 | 01-NOV-07:10 | 14019.75 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 6443.98 | 01-DEC-08:09 | 14019.75 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 6443.98 | 14019.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 6443.98 | 14019.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 6443.98 | 02-JAN-08:09 | 6808.32 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 6443.98 | 01-FEB-08:09 | 6808.32 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 6443.98 | 01-MAR-08:09 | 6808.32 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 6443.98 | 03-APR-07:10 | 6808.32 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 6443.98 | 01-MAY-07:10 | 6808.32 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 6443.98 | 01-JUN-07:10 | 6808.32 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 6443.98 | 03-JUL-07:10 | 6808.32 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 6443.98 | 01-AUG-07:10 | 6808.32 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 6443.98 | 01-SEP-07:10 | 6808.32 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 6443.98 | 02-OCT-07:10 | 6808.32 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 6443.98 | 01-NOV-07:10 | 6808.32 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 6443.98 | 01-DEC-08:09 | 6808.32 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 6443.98 | 02-JAN-08:09 | 6808.32 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 6443.98 | 01-FEB-08:09 | 6808.32 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 6443.98 | 01-MAR-08:09 | 6808.32 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 6443.98 | 03-APR-07:10 | 6808.32 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 6443.98 | 01-MAY-07:10 | 6808.32 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 6443.98 | 01-JUN-07:10 | 6808.32 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 6443.98 | 03-JUL-07:10 | 6808.32 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 6443.98 | 01-AUG-07:10 | 6808.32 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 6443.98 | 01-SEP-07:10 | 6808.32 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 6443.98 | 02-OCT-07:10 | 6808.32 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 6443.98 | 01-NOV-07:10 | 6808.32 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 6443.98 | 01-DEC-08:09 | 6808.32 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1358.45 | 02-JAN-08:09 | 1435.25 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 323.84 | 08-JAN-08:00 |
February | 1306.65 | 01-FEB-10:09 | 1358.45 | 01-FEB-08:09 | 1435.25 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 350.91 | 08-FEB-22:05 |
March | 1306.65 | 01-MAR-10:09 | 1184.79 | 15-MAR-07:10 | 1435.25 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 349.92 | 27-MAR-21:05 |
April | 1306.65 | 03-APR-09:09 | 1184.79 | 10-APR-07:10 | 1435.25 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 352.53 | 23-APR-22:00 |
May | 1306.65 | 01-MAY-09:09 | 711.15 | 03-MAY-07:10 | 1435.25 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 556.48 | 04-MAY-23:00 |
June | 1306.65 | 01-JUN-09:09 | 647.98 | 01-JUN-07:10 | 1435.25 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.24 | 13-JUN-15:30 | 406.73 | 05-JUN-21:20 |
July | 1306.65 | 03-JUL-09:09 | 711.15 | 07-JUL-07:10 | 1435.25 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.44 | 22-JUL-17:01 | 362.51 | 30-JUL-18:30 |
August | 1306.65 | 01-AUG-09:09 | 947.97 | 22-AUG-07:19 | 1435.25 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7.79 | 14-AUG-16:50 | 268.62 | 22-AUG-21:10 |
September | 1306.65 | 01-SEP-09:09 | 947.97 | 08-SEP-07:10 | 1435.25 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 333.43 | 06-SEP-04:00 |
October | 1306.65 | 02-OCT-09:09 | 1358.45 | 16-OCT-07:10 | 1435.25 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 402.45 | 20-OCT-22:00 |
November | 1306.65 | 01-NOV-09:09 | 1358.45 | 01-NOV-07:10 | 1435.25 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 375.91 | 25-NOV-05:00 |
December | 1306.65 | 01-DEC-10:09 | 1358.45 | 01-DEC-08:09 | 1435.25 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 633.08 | 02-DEC-18:05 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 268.62 | |||||
Maximum of Months | 1306.65 | 1358.45 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 31.44 | 633.08 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.22 | 02-JAN-10:09 | 860.01 | 02-JAN-08:09 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 215.39 | 08-JAN-08:00 |
February | 827.22 | 01-FEB-10:09 | 860.01 | 01-FEB-08:09 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 233.64 | 08-FEB-22:05 |
March | 827.22 | 01-MAR-10:09 | 750.07 | 15-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 233.03 | 27-MAR-21:05 |
April | 827.22 | 03-APR-09:09 | 600.14 | 10-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 234.51 | 23-APR-22:00 |
May | 827.22 | 01-MAY-09:09 | 450.21 | 15-MAY-15:09 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 366.92 | 04-MAY-23:00 |
June | 827.22 | 01-JUN-09:09 | 410.22 | 01-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.82 | 13-JUN-15:30 | 318.00 | 18-JUN-11:00 |
July | 827.22 | 03-JUL-09:09 | 450.21 | 07-JUL-15:30 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.22 | 22-JUL-19:10 | 244.61 | 30-JUL-18:30 |
August | 827.22 | 01-AUG-09:09 | 490.21 | 22-AUG-07:30 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5.19 | 14-AUG-16:50 | 174.01 | 22-AUG-21:10 |
September | 827.22 | 01-SEP-09:09 | 600.14 | 08-SEP-07:30 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 223.30 | 06-SEP-04:00 |
October | 827.22 | 02-OCT-09:09 | 860.01 | 16-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 266.15 | 20-OCT-22:00 |
November | 827.22 | 01-NOV-09:09 | 860.01 | 01-NOV-07:10 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 248.41 | 25-NOV-05:00 |
December | 827.22 | 01-DEC-10:09 | 860.01 | 01-DEC-08:09 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 418.33 | 02-DEC-18:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 174.01 | |||||
Maximum of Months | 827.22 | 860.01 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 27.22 | 418.33 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1358.45 | 02-JAN-08:09 | 1435.24 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 332.69 | 08-JAN-08:00 |
February | 1306.65 | 01-FEB-10:09 | 1358.45 | 01-FEB-08:09 | 1435.24 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 352.05 | 08-FEB-22:05 |
March | 1306.65 | 01-MAR-10:09 | 1184.79 | 15-MAR-07:10 | 1435.24 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 349.91 | 27-MAR-21:05 |
April | 1306.65 | 03-APR-09:09 | 1184.79 | 10-APR-07:10 | 1435.24 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 394.53 | 16-APR-12:00 |
May | 1306.65 | 01-MAY-09:09 | 711.15 | 03-MAY-07:10 | 1435.24 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 554.96 | 04-MAY-23:00 |
June | 1306.65 | 01-JUN-09:09 | 647.98 | 01-JUN-07:10 | 1435.24 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.23 | 13-JUN-15:30 | 447.62 | 18-JUN-16:00 |
July | 1306.65 | 03-JUL-09:09 | 711.15 | 07-JUL-07:10 | 1435.24 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.44 | 22-JUL-19:10 | 393.54 | 30-JUL-17:10 |
August | 1306.65 | 01-AUG-09:09 | 947.97 | 22-AUG-07:19 | 1435.24 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7.79 | 14-AUG-16:50 | 272.53 | 22-AUG-21:10 |
September | 1306.65 | 01-SEP-09:09 | 947.97 | 08-SEP-07:10 | 1435.24 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 338.31 | 06-SEP-04:00 |
October | 1306.65 | 02-OCT-09:09 | 1358.45 | 16-OCT-07:10 | 1435.24 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 411.81 | 01-OCT-24:00 |
November | 1306.65 | 01-NOV-09:09 | 1358.45 | 01-NOV-07:10 | 1435.24 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 377.65 | 26-NOV-04:00 |
December | 1306.65 | 01-DEC-10:09 | 1358.45 | 01-DEC-08:09 | 1435.24 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 640.08 | 02-DEC-18:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 272.53 | |||||
Maximum of Months | 1306.65 | 1358.45 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 37.44 | 640.08 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 859.95 | 02-JAN-08:09 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 215.28 | 08-JAN-08:00 |
February | 827.17 | 01-FEB-10:09 | 859.95 | 01-FEB-08:09 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 234.28 | 08-FEB-22:05 |
March | 827.17 | 01-MAR-10:09 | 859.95 | 15-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 233.10 | 27-MAR-21:05 |
April | 827.17 | 03-APR-09:09 | 750.02 | 10-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 233.49 | 23-APR-22:00 |
May | 827.17 | 01-MAY-09:09 | 490.17 | 03-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 368.95 | 04-MAY-23:00 |
June | 827.17 | 01-JUN-09:09 | 450.19 | 05-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.82 | 13-JUN-15:30 | 329.84 | 18-JUN-16:00 |
July | 827.17 | 03-JUL-09:09 | 450.19 | 07-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.29 | 22-JUL-19:10 | 327.00 | 30-JUL-17:10 |
August | 827.17 | 01-AUG-09:09 | 600.10 | 22-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5.19 | 14-AUG-16:50 | 185.88 | 22-AUG-21:10 |
September | 827.17 | 01-SEP-09:09 | 750.02 | 08-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 222.77 | 06-SEP-04:00 |
October | 827.17 | 02-OCT-09:09 | 859.95 | 16-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 270.77 | 20-OCT-22:00 |
November | 827.17 | 01-NOV-09:09 | 859.95 | 01-NOV-07:10 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 248.28 | 25-NOV-05:00 |
December | 827.17 | 01-DEC-10:09 | 859.95 | 01-DEC-08:09 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 417.23 | 02-DEC-18:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 450.19 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 185.88 | |||||
Maximum of Months | 827.17 | 859.95 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 18.29 | 417.23 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1358.45 | 02-JAN-08:09 | 1435.25 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 196.25 | 08-JAN-08:00 |
February | 1306.65 | 01-FEB-10:09 | 1358.45 | 01-FEB-08:09 | 1435.25 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 187.58 | 08-FEB-22:05 |
March | 1306.65 | 01-MAR-10:09 | 1184.79 | 15-MAR-07:10 | 1435.25 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 186.98 | 27-MAR-21:05 |
April | 1306.65 | 03-APR-09:09 | 1184.79 | 10-APR-07:10 | 1435.25 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.55 | 30-APR-19:00 | 200.00 | 23-APR-22:00 |
May | 1306.65 | 01-MAY-09:09 | 711.15 | 03-MAY-07:10 | 1435.25 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22-MAY-15:00 | 312.00 | 04-MAY-23:00 |
June | 1306.65 | 01-JUN-09:09 | 647.98 | 01-JUN-07:10 | 1435.25 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5.57 | 13-JUN-15:30 | 218.69 | 05-JUN-21:20 |
July | 1306.65 | 03-JUL-09:09 | 711.15 | 07-JUL-07:10 | 1435.25 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.75 | 22-JUL-19:10 | 202.32 | 30-JUL-18:53 |
August | 1306.65 | 01-AUG-09:09 | 947.97 | 22-AUG-07:30 | 1435.25 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.22 | 14-AUG-16:50 | 145.80 | 22-AUG-21:10 |
September | 1306.65 | 01-SEP-09:09 | 947.97 | 08-SEP-07:10 | 1435.25 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 194.76 | 06-SEP-04:00 |
October | 1306.65 | 02-OCT-09:09 | 1358.45 | 16-OCT-07:10 | 1435.25 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 230.66 | 20-OCT-22:00 |
November | 1306.65 | 01-NOV-09:09 | 1358.45 | 01-NOV-07:10 | 1435.25 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 229.23 | 25-NOV-05:00 |
December | 1306.65 | 01-DEC-10:09 | 1358.45 | 01-DEC-08:09 | 1435.25 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 357.03 | 02-DEC-18:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 145.80 | |||||
Maximum of Months | 1306.65 | 1358.45 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 21.75 | 357.03 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.22 | 02-JAN-10:09 | 860.01 | 02-JAN-08:09 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 131.85 | 08-JAN-08:00 |
February | 827.22 | 01-FEB-10:09 | 860.01 | 01-FEB-08:09 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 125.00 | 08-FEB-22:05 |
March | 827.22 | 01-MAR-10:09 | 750.07 | 15-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 124.66 | 27-MAR-21:05 |
April | 827.22 | 03-APR-09:09 | 600.14 | 10-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 137.12 | 23-APR-22:00 |
May | 827.22 | 01-MAY-09:09 | 450.21 | 15-MAY-15:09 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22-MAY-15:00 | 207.76 | 04-MAY-23:00 |
June | 827.22 | 01-JUN-09:09 | 410.22 | 01-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3.71 | 13-JUN-15:30 | 165.24 | 18-JUN-10:53 |
July | 827.22 | 03-JUL-09:09 | 450.21 | 07-JUL-15:30 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.60 | 22-JUL-19:10 | 142.04 | 30-JUL-18:53 |
August | 827.22 | 01-AUG-09:09 | 490.21 | 22-AUG-07:30 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2.81 | 14-AUG-16:50 | 99.77 | 22-AUG-21:10 |
September | 827.22 | 01-SEP-09:09 | 600.14 | 08-SEP-07:30 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 137.44 | 06-SEP-04:00 |
October | 827.22 | 02-OCT-09:09 | 860.01 | 16-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 155.75 | 01-OCT-24:00 |
November | 827.22 | 01-NOV-09:09 | 860.01 | 01-NOV-07:10 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 151.14 | 26-NOV-04:00 |
December | 827.22 | 01-DEC-10:09 | 860.01 | 01-DEC-08:09 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 236.65 | 02-DEC-18:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 99.77 | |||||
Maximum of Months | 827.22 | 860.01 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 14.60 | 236.65 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1358.45 | 02-JAN-08:09 | 1435.24 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 20860.45 | 10-JAN-07:01 |
February | 1306.65 | 01-FEB-10:09 | 1358.45 | 01-FEB-08:09 | 1435.24 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 20644.35 | 17-FEB-07:01 |
March | 1306.65 | 01-MAR-10:09 | 1184.79 | 15-MAR-07:10 | 1435.24 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 17528.10 | 08-MAR-07:01 |
April | 1306.65 | 03-APR-09:09 | 1184.79 | 10-APR-07:10 | 1435.24 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 14676.23 | 20-APR-06:02 |
May | 1306.65 | 01-MAY-09:09 | 711.15 | 03-MAY-07:10 | 1435.24 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.14 | 22-MAY-15:00 | 13351.86 | 02-MAY-06:03 |
June | 1306.65 | 01-JUN-09:09 | 647.98 | 01-JUN-07:10 | 1435.24 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2392.81 | 13-JUN-17:00 | 11020.17 | 08-JUN-06:03 |
July | 1306.65 | 03-JUL-09:09 | 711.15 | 07-JUL-07:10 | 1435.24 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3971.60 | 21-JUL-17:00 | 9829.69 | 05-JUL-06:03 |
August | 1306.65 | 01-AUG-09:09 | 947.97 | 22-AUG-07:30 | 1435.24 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2396.27 | 14-AUG-17:00 | 10391.43 | 24-AUG-06:03 |
September | 1306.65 | 01-SEP-09:09 | 947.97 | 08-SEP-07:19 | 1435.24 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 13405.05 | 21-SEP-06:03 |
October | 1306.65 | 02-OCT-09:09 | 1358.45 | 16-OCT-07:10 | 1435.24 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 15361.53 | 04-OCT-06:02 |
November | 1306.65 | 01-NOV-09:09 | 1358.45 | 01-NOV-07:10 | 1435.24 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 18210.45 | 29-NOV-07:01 |
December | 1306.65 | 01-DEC-10:09 | 1358.45 | 01-DEC-08:09 | 1435.24 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 19708.87 | 29-DEC-17:01 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9829.69 | |||||
Maximum of Months | 1306.65 | 1358.45 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 3971.60 | 20860.45 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 859.95 | 02-JAN-08:09 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 130.86 | 08-JAN-08:00 |
February | 827.17 | 01-FEB-10:09 | 859.95 | 01-FEB-08:09 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 125.32 | 08-FEB-22:05 |
March | 827.17 | 01-MAR-10:09 | 859.95 | 15-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 124.56 | 27-MAR-21:05 |
April | 827.17 | 03-APR-09:09 | 750.02 | 10-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 135.55 | 23-APR-22:00 |
May | 827.17 | 01-MAY-09:09 | 490.17 | 04-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22-MAY-15:00 | 209.92 | 04-MAY-23:00 |
June | 827.17 | 01-JUN-09:09 | 450.19 | 14-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3.71 | 13-JUN-15:30 | 170.52 | 18-JUN-16:00 |
July | 827.17 | 03-JUL-09:09 | 450.19 | 07-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.55 | 22-JUL-19:10 | 176.33 | 30-JUL-18:53 |
August | 827.17 | 01-AUG-09:09 | 600.10 | 22-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2.81 | 14-AUG-16:50 | 107.76 | 22-AUG-21:10 |
September | 827.17 | 01-SEP-09:09 | 750.02 | 08-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 133.63 | 06-SEP-04:00 |
October | 827.17 | 02-OCT-09:09 | 859.95 | 16-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 157.45 | 01-OCT-24:00 |
November | 827.17 | 01-NOV-09:09 | 859.95 | 01-NOV-07:10 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 150.90 | 25-NOV-05:00 |
December | 827.17 | 01-DEC-10:09 | 859.95 | 01-DEC-08:09 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 235.81 | 02-DEC-18:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 450.19 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 107.76 | |||||
Maximum of Months | 827.17 | 859.95 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 9.55 | 235.81 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1358.45 | 02-JAN-08:09 | 1435.25 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 304.40 | 08-JAN-08:00 |
February | 1306.65 | 01-FEB-10:09 | 1358.45 | 01-FEB-08:09 | 1435.25 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 295.06 | 08-FEB-22:05 |
March | 1306.65 | 01-MAR-10:09 | 1184.79 | 15-MAR-07:10 | 1435.25 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 293.88 | 27-MAR-21:05 |
April | 1306.65 | 03-APR-09:09 | 1184.79 | 10-APR-07:10 | 1435.25 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 320.53 | 23-APR-22:00 |
May | 1306.65 | 01-MAY-09:09 | 711.15 | 03-MAY-07:10 | 1435.25 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 495.33 | 04-MAY-23:00 |
June | 1306.65 | 01-JUN-09:09 | 647.98 | 01-JUN-07:10 | 1435.25 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.62 | 13-JUN-15:30 | 349.50 | 05-JUN-21:20 |
July | 1306.65 | 03-JUL-09:09 | 711.15 | 07-JUL-07:10 | 1435.25 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.64 | 22-JUL-19:10 | 321.22 | 30-JUL-19:00 |
August | 1306.65 | 01-AUG-09:09 | 947.97 | 22-AUG-07:19 | 1435.25 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.55 | 14-AUG-16:50 | 233.69 | 22-AUG-21:10 |
September | 1306.65 | 01-SEP-09:09 | 947.97 | 08-SEP-07:10 | 1435.25 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 304.80 | 06-SEP-04:00 |
October | 1306.65 | 02-OCT-09:09 | 1358.45 | 16-OCT-07:10 | 1435.25 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 359.42 | 20-OCT-22:00 |
November | 1306.65 | 01-NOV-09:09 | 1358.45 | 01-NOV-07:10 | 1435.25 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 348.61 | 25-NOV-05:00 |
December | 1306.65 | 01-DEC-10:09 | 1358.45 | 01-DEC-08:09 | 1435.25 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 552.27 | 02-DEC-18:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 233.69 | |||||
Maximum of Months | 1306.65 | 1358.45 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 28.64 | 552.27 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 805.43 | 02-JAN-08:09 | 860.01 | 02-JAN-08:09 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 202.41 | 08-JAN-08:00 |
February | 805.43 | 01-FEB-08:09 | 860.01 | 01-FEB-08:09 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 196.35 | 08-FEB-22:05 |
March | 805.43 | 01-MAR-08:09 | 750.07 | 15-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 195.65 | 27-MAR-21:05 |
April | 805.43 | 03-APR-07:10 | 600.14 | 10-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 213.11 | 23-APR-22:00 |
May | 805.43 | 01-MAY-07:10 | 450.21 | 15-MAY-15:09 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 325.04 | 04-MAY-23:00 |
June | 805.43 | 01-JUN-07:10 | 410.22 | 01-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5.75 | 13-JUN-15:30 | 264.79 | 18-JUN-10:23 |
July | 805.43 | 03-JUL-07:10 | 450.21 | 07-JUL-15:30 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.81 | 22-JUL-19:10 | 212.75 | 30-JUL-19:00 |
August | 805.43 | 01-AUG-07:10 | 490.21 | 22-AUG-07:30 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.36 | 14-AUG-16:50 | 150.91 | 22-AUG-21:10 |
September | 805.43 | 01-SEP-07:10 | 600.14 | 08-SEP-07:30 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 203.50 | 06-SEP-04:00 |
October | 805.43 | 02-OCT-07:10 | 860.01 | 16-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 236.63 | 20-OCT-22:00 |
November | 805.43 | 01-NOV-07:10 | 860.01 | 01-NOV-07:10 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 230.05 | 25-NOV-05:00 |
December | 805.43 | 01-DEC-08:09 | 860.01 | 01-DEC-08:09 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 364.78 | 02-DEC-18:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 805.43 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 150.91 | |||||
Maximum of Months | 805.43 | 860.01 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 24.81 | 364.78 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1358.45 | 02-JAN-08:09 | 1435.24 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 312.00 | 08-JAN-08:00 |
February | 1306.65 | 01-FEB-10:09 | 1358.45 | 01-FEB-08:09 | 1435.24 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 308.96 | 05-FEB-14:00 |
March | 1306.65 | 01-MAR-10:09 | 1184.79 | 15-MAR-07:10 | 1435.24 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 293.84 | 27-MAR-21:05 |
April | 1306.65 | 03-APR-09:09 | 1184.79 | 10-APR-07:10 | 1435.24 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 321.76 | 23-APR-22:00 |
May | 1306.65 | 01-MAY-09:09 | 711.15 | 03-MAY-07:10 | 1435.24 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 493.29 | 04-MAY-23:00 |
June | 1306.65 | 01-JUN-09:09 | 647.98 | 01-JUN-07:10 | 1435.24 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.62 | 13-JUN-15:30 | 370.82 | 18-JUN-16:00 |
July | 1306.65 | 03-JUL-09:09 | 711.15 | 07-JUL-07:10 | 1435.24 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.90 | 22-JUL-19:10 | 341.08 | 30-JUL-19:00 |
August | 1306.65 | 01-AUG-09:09 | 947.97 | 22-AUG-07:19 | 1435.24 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.55 | 14-AUG-16:50 | 237.06 | 22-AUG-21:10 |
September | 1306.65 | 01-SEP-09:09 | 947.97 | 08-SEP-07:10 | 1435.24 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 308.45 | 06-SEP-04:00 |
October | 1306.65 | 02-OCT-09:09 | 1358.45 | 16-OCT-07:10 | 1435.24 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 373.89 | 01-OCT-24:00 |
November | 1306.65 | 01-NOV-09:09 | 1358.45 | 01-NOV-07:10 | 1435.24 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 351.85 | 26-NOV-04:00 |
December | 1306.65 | 01-DEC-10:09 | 1358.45 | 01-DEC-08:09 | 1435.24 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 559.36 | 02-DEC-18:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 237.06 | |||||
Maximum of Months | 1306.65 | 1358.45 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 33.90 | 559.36 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 859.95 | 02-JAN-08:09 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 202.32 | 08-JAN-08:00 |
February | 827.17 | 01-FEB-10:09 | 859.95 | 01-FEB-08:09 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 197.04 | 08-FEB-22:05 |
March | 827.17 | 01-MAR-10:09 | 859.95 | 15-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 195.70 | 27-MAR-21:05 |
April | 827.17 | 03-APR-09:09 | 750.02 | 10-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 212.38 | 23-APR-22:00 |
May | 827.17 | 01-MAY-09:09 | 490.17 | 03-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 327.98 | 04-MAY-23:00 |
June | 827.17 | 01-JUN-09:09 | 450.19 | 05-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5.75 | 13-JUN-15:30 | 274.62 | 18-JUN-16:00 |
July | 827.17 | 03-JUL-09:09 | 450.19 | 07-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.59 | 22-JUL-19:08 | 274.60 | 30-JUL-19:00 |
August | 827.17 | 01-AUG-09:09 | 600.10 | 22-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.36 | 14-AUG-16:50 | 161.43 | 22-AUG-21:10 |
September | 827.17 | 01-SEP-09:09 | 750.02 | 08-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 203.42 | 06-SEP-04:00 |
October | 827.17 | 02-OCT-09:09 | 859.95 | 16-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 240.97 | 20-OCT-22:00 |
November | 827.17 | 01-NOV-09:09 | 859.95 | 01-NOV-07:10 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 229.95 | 25-NOV-05:00 |
December | 827.17 | 01-DEC-10:09 | 859.95 | 01-DEC-08:09 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 364.25 | 02-DEC-18:10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 450.19 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 161.43 | |||||
Maximum of Months | 827.17 | 859.95 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 14.59 | 364.25 |
Report: PeakSpaceGainsMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 445.20 | 08-JAN-08:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 410.06 | 08-FEB-22:05 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 402.96 | 27-MAR-21:05 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 454.90 | 23-APR-22:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 696.55 | 04-MAY-23:00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.45 | 13-JUN-16:00 | 474.92 | 05-JUN-22:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.65 | 22-JUL-18:52 | 444.72 | 30-JUL-19:00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.09 | 14-AUG-17:00 | 326.84 | 22-AUG-21:10 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 436.09 | 06-SEP-04:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 513.00 | 20-OCT-22:00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 516.78 | 25-NOV-05:00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 806.65 | 02-DEC-18:05 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 326.84 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.65 | 806.65 |
Report: PeakSpaceGainsMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 538.17 | 08-JAN-08:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 504.67 | 08-FEB-22:05 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 492.23 | 27-MAR-21:05 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 557.80 | 23-APR-22:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 870.98 | 04-MAY-23:00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.53 | 13-JUN-16:00 | 601.93 | 05-JUN-22:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.05 | 22-JUL-18:52 | 547.03 | 30-JUL-19:00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.89 | 14-AUG-17:00 | 414.17 | 22-AUG-21:10 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 538.49 | 06-SEP-04:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 622.72 | 20-OCT-22:00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 612.69 | 25-NOV-05:00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 969.82 | 02-DEC-18:05 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 414.17 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.05 | 969.82 |
Report: PeakSpaceGainsMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 477.22 | 08-JAN-08:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 518.92 | 08-FEB-22:05 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 523.00 | 27-MAR-21:05 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 534.31 | 23-APR-22:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 851.93 | 04-MAY-23:00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.94 | 13-JUN-17:00 | 705.93 | 18-JUN-16:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.10 | 22-JUL-18:52 | 635.95 | 30-JUL-18:43 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.32 | 14-AUG-18:00 | 413.40 | 22-AUG-21:03 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 490.49 | 06-SEP-04:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 597.91 | 20-OCT-22:00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 567.35 | 25-NOV-05:00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1032.60 | 02-DEC-18:05 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 413.40 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.10 | 1032.60 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 14068.31 | 20-JAN-16:40 | 6035.01 | 6443.98 | 13991.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 14312.18 | 10-FEB-17:00 | 6035.01 | 6443.98 | 13991.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 14668.57 | 31-MAR-16:00 | 6035.01 | 6443.98 | 13991.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 32933.75 | 20-APR-05:03 | 2541.06 | 846.94 | 29641.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 36998.64 | 01-MAY-06:02 | 6352.64 | 10740.11 | 50974.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 39561.15 | 27-JUN-05:12 | 2541.06 | 2863.91 | 29641.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 39737.31 | 25-JUL-05:12 | 2541.06 | 2863.91 | 29641.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 37964.76 | 07-AUG-06:02 | 7623.17 | 12888.13 | 61169.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 37154.06 | 13-SEP-06:02 | 7623.17 | 12888.13 | 61169.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 36039.28 | 02-OCT-06:02 | 7623.17 | 12888.13 | 61169.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 15480.35 | 03-NOV-16:00 | 6035.01 | 6443.98 | 13991.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 12398.27 | 22-DEC-17:00 | 6035.01 | 6443.98 | 13991.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 12398.27 | 2541.06 | 846.94 | 13991.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 39737.31 | 7623.17 | 12888.13 | 61169.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 676.94 | 19-JAN-17:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 1051.29 | 04-FEB-15:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.18 |
March | 2033.93 | 25-MAR-12:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.89 |
April | 7452.19 | 28-APR-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.96 |
May | 8010.25 | 22-MAY-14:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 |
June | 8958.91 | 13-JUN-14:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.79 |
July | 8953.36 | 21-JUL-14:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.49 | 0.00 |
August | 8103.16 | 14-AUG-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.42 |
September | 6853.64 | 13-SEP-14:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.61 |
October | 3299.64 | 03-OCT-14:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62.01 |
November | 747.03 | 11-NOV-13:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 235.11 |
December | 103.01 | 06-DEC-13:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37.98 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 103.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 8958.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.49 | 235.11 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1778.65 | 07-JAN-06:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.63 |
February | 1753.80 | 10-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.58 |
March | 2308.97 | 24-MAR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 2512.61 | 28-APR-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.66 |
May | 2810.89 | 23-MAY-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.10 |
June | 3617.69 | 13-JUN-15:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.34 | 0.00 |
July | 3760.07 | 24-JUL-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.72 |
August | 3191.19 | 14-AUG-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.43 | 0.00 |
September | 2976.19 | 13-SEP-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.37 |
October | 2187.13 | 19-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.08 |
November | 2035.71 | 01-NOV-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.58 |
December | 1755.86 | 23-DEC-06:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76.99 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 1753.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3760.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.34 | 76.99 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2377.75 | 26-JAN-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 2576.98 | 09-FEB-06:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.64 |
March | 2761.13 | 24-MAR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 2980.67 | 28-APR-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.70 |
May | 3824.72 | 01-MAY-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.42 |
June | 4079.24 | 13-JUN-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.45 | 0.00 |
July | 4226.27 | 24-JUL-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.11 |
August | 3861.82 | 14-AUG-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.80 | 0.00 |
September | 3671.81 | 13-SEP-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.86 |
October | 2940.21 | 04-OCT-06:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.05 |
November | 2648.14 | 01-NOV-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.05 |
December | 2290.27 | 08-DEC-06:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.47 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 2290.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 4226.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.45 | 89.42 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 7443.56 | 20-JAN-17:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 7424.40 | 24-FEB-17:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 7525.61 | 31-MAR-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 14447.29 | 28-APR-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 15267.01 | 23-MAY-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 16376.02 | 26-JUN-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 29168.52 | 24-JUL-06:02 | 7623.17 | 12888.13 | 18155.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 15789.41 | 18-AUG-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 15523.09 | 13-SEP-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 12744.32 | 03-OCT-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 7621.15 | 10-NOV-17:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6982.66 | 21-DEC-15:10 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 6982.66 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 29168.52 | 7623.17 | 12888.13 | 18155.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 7205.49 | 19-JAN-16:40 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 7222.50 | 09-FEB-17:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 7437.17 | 31-MAR-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 15486.41 | 28-APR-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 16518.77 | 23-MAY-15:50 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 18016.11 | 13-JUN-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 18192.66 | 24-JUL-15:50 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 16786.14 | 18-AUG-15:50 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 16078.89 | 13-SEP-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 11624.27 | 03-OCT-16:00 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 7458.98 | 10-NOV-16:30 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6736.36 | 21-DEC-15:30 | 12070.02 | 12887.96 | 13616.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 6736.36 | 6035.01 | 6443.98 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 18192.66 | 12070.02 | 12887.96 | 13616.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1262.03 | 19-JAN-15:40 | 1272.23 | 711.15 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 1240.12 | 09-FEB-16:00 | 1272.23 | 711.15 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.43 |
March | 1425.85 | 30-MAR-15:50 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77.08 |
April | 3804.61 | 28-APR-15:30 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.66 |
May | 4318.32 | 22-MAY-15:20 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.08 |
June | 5454.33 | 13-JUN-15:50 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 10.21 | 0.00 |
July | 5218.98 | 10-JUL-15:00 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.42 |
August | 4710.23 | 14-AUG-16:00 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 7.13 | 0.00 |
September | 4051.55 | 13-SEP-15:30 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.60 |
October | 1815.15 | 06-OCT-15:50 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.44 |
November | 1355.10 | 10-NOV-15:30 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.51 |
December | 1120.64 | 21-DEC-15:20 | 1272.23 | 1358.45 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.63 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1120.64 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 5454.33 | 1272.23 | 1358.45 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 10.21 | 77.08 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1335.74 | 20-JAN-10:40 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 1434.03 | 24-FEB-10:30 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.61 |
March | 1376.12 | 25-MAR-09:50 | 261.23 | 136.74 | 504.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 11755.35 | 30-APR-10:23 | 169.56 | 91.16 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.27 |
May | 10044.40 | 21-MAY-08:43 | 169.56 | 91.16 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83.19 |
June | 12188.84 | 25-JUN-09:53 | 169.56 | 91.16 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 13410.65 | 23-JUL-09:02 | 211.95 | 113.95 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55.09 |
August | 10849.79 | 20-AUG-10:02 | 169.56 | 91.16 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.19 |
September | 6535.26 | 12-SEP-09:20 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.33 |
October | 3311.18 | 04-OCT-10:00 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 1323.40 | 03-NOV-09:50 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.57 |
December | 1149.91 | 06-DEC-10:20 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.39 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1149.91 | 169.56 | 91.16 | 504.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 13410.65 | 827.22 | 410.22 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.19 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 6240.59 | 20-JAN-12:00 | 1272.23 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 7878.71 | 17-FEB-13:40 | 2544.47 | 1295.96 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.93 |
March | 3943.94 | 28-MAR-12:17 | 3816.70 | 1943.94 | 4305.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.33 |
April | 20128.31 | 30-APR-13:02 | 334.80 | 179.99 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.83 |
May | 10123.44 | 22-MAY-13:10 | 1306.65 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.22 |
June | 11541.59 | 11-JUN-13:53 | 267.84 | 143.99 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 114.23 |
July | 18759.48 | 23-JUL-12:23 | 267.84 | 143.99 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69.56 |
August | 20560.91 | 06-AUG-13:22 | 334.80 | 179.99 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 116.99 |
September | 19359.86 | 10-SEP-11:53 | 267.84 | 143.99 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.47 |
October | 15330.59 | 01-OCT-13:53 | 267.84 | 143.99 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 153.21 |
November | 6854.84 | 03-NOV-12:40 | 2544.47 | 1295.96 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 73.09 |
December | 5217.33 | 18-DEC-13:25 | 2544.47 | 1295.96 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.99 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 3943.94 | 267.84 | 143.99 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 20560.91 | 3816.70 | 1943.94 | 4305.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 153.21 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1675.81 | 19-JAN-16:00 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 2601.98 | 27-FEB-16:30 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 2808.33 | 23-MAR-16:50 | 254.33 | 227.89 | 504.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.58 |
April | 14439.39 | 30-APR-16:22 | 211.94 | 113.94 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.20 |
May | 12489.93 | 21-MAY-16:32 | 211.94 | 113.94 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 73.10 |
June | 15963.23 | 11-JUN-16:32 | 254.33 | 136.73 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110.30 |
July | 16528.10 | 09-JUL-17:11 | 0.00 | 159.52 | 1710.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.35 |
August | 15761.93 | 13-AUG-17:02 | 0.00 | 136.73 | 1466.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71.61 |
September | 11243.94 | 10-SEP-16:33 | 169.55 | 91.15 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 65.75 |
October | 5192.09 | 03-OCT-15:40 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.92 |
November | 1709.65 | 10-NOV-15:40 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.61 |
December | 1370.66 | 21-DEC-14:40 | 827.17 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.95 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1370.66 | 0.00 | 91.15 | 504.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16528.10 | 827.17 | 410.20 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110.30 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1210.59 | 25-JAN-15:00 | 1306.65 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.98 |
February | 1181.76 | 10-FEB-16:00 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.58 |
March | 1329.58 | 30-MAR-14:00 | 1306.65 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.79 |
April | 2220.57 | 28-APR-15:40 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.56 |
May | 2655.61 | 23-MAY-14:00 | 1306.65 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.17 |
June | 3956.43 | 13-JUN-16:00 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 5.51 | 0.00 |
July | 3867.46 | 21-JUL-16:00 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 3349.84 | 14-AUG-16:00 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 3.89 | 0.00 |
September | 3025.93 | 13-SEP-15:30 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.82 |
October | 1642.47 | 02-OCT-06:02 | 1607.03 | 2716.93 | 3827.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.95 |
November | 1354.99 | 10-NOV-15:00 | 1306.65 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.48 |
December | 1139.20 | 21-DEC-14:50 | 1306.65 | 711.15 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.43 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1139.20 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3956.43 | 1607.03 | 2716.93 | 3827.32 | 0.00 | 0.00 | 0.00 | 0.00 | 5.51 | 30.98 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1121.29 | 20-JAN-10:30 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 1175.92 | 24-FEB-10:30 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.10 |
March | 1117.29 | 31-MAR-09:50 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.22 |
April | 8882.26 | 30-APR-10:13 | 169.56 | 91.16 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.99 |
May | 7127.82 | 23-MAY-06:02 | 847.82 | 683.72 | 2019.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.81 |
June | 8083.32 | 25-JUN-09:53 | 169.56 | 91.16 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 10398.08 | 23-JUL-08:52 | 254.35 | 136.74 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.97 |
August | 6288.79 | 13-AUG-09:53 | 169.56 | 91.16 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.74 |
September | 5371.81 | 12-SEP-09:20 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.92 |
October | 3025.20 | 04-OCT-10:00 | 827.22 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 1153.56 | 03-NOV-09:35 | 1654.44 | 820.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.87 |
December | 1012.13 | 08-DEC-10:30 | 1654.44 | 820.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.27 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1012.13 | 169.56 | 91.16 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 10398.08 | 1654.44 | 820.45 | 2019.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.74 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3322.29 | 21-JAN-11:30 | 401.76 | 216.00 | 797.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 3820.43 | 04-FEB-14:00 | 133.92 | 107.99 | 558.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.01 |
March | 1801.26 | 25-MAR-11:50 | 137.54 | 107.99 | 558.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 16398.41 | 30-APR-13:31 | 468.72 | 251.99 | 3348.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.09 |
May | 7323.13 | 22-MAY-13:50 | 1306.65 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 124.94 |
June | 7662.49 | 13-JUN-13:40 | 1306.65 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 78.66 | 0.00 |
July | 9193.36 | 23-JUL-13:32 | 334.80 | 179.99 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.72 |
August | 16285.70 | 06-AUG-13:22 | 334.80 | 179.99 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.85 |
September | 14243.08 | 10-SEP-13:22 | 401.76 | 215.99 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.27 |
October | 10472.26 | 03-OCT-12:07 | 3816.70 | 1943.94 | 4305.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1238.70 |
November | 3849.29 | 11-NOV-13:13 | 200.88 | 107.99 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 105.92 |
December | 1952.07 | 18-DEC-13:50 | 1272.23 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1814.48 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1801.26 | 133.92 | 107.99 | 558.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16398.41 | 3816.70 | 1943.94 | 4305.71 | 0.00 | 0.00 | 0.00 | 0.00 | 78.66 | 1814.48 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1353.85 | 19-JAN-15:50 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 1717.55 | 27-FEB-16:30 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 1750.50 | 23-MAR-17:00 | 254.33 | 227.89 | 504.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.81 |
April | 12390.53 | 30-APR-17:31 | 0.00 | 159.52 | 1710.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.55 |
May | 8714.36 | 21-MAY-16:52 | 254.33 | 136.73 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.07 |
June | 12499.57 | 11-JUN-16:32 | 254.33 | 136.73 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.43 |
July | 12204.15 | 09-JUL-17:41 | 0.00 | 159.52 | 1710.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.62 |
August | 11051.18 | 06-AUG-16:42 | 211.94 | 113.94 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.22 |
September | 6112.63 | 12-SEP-16:00 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.95 |
October | 4399.97 | 03-OCT-16:00 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.80 |
November | 1415.75 | 10-NOV-15:40 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.41 |
December | 1151.91 | 21-DEC-14:50 | 827.17 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.73 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1151.91 | 0.00 | 113.94 | 504.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 12499.57 | 827.17 | 410.20 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.43 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1295.68 | 19-JAN-15:40 | 1272.23 | 711.15 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 1286.71 | 24-FEB-16:00 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.82 |
March | 1448.50 | 30-MAR-15:40 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55.78 |
April | 3600.68 | 28-APR-15:30 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.16 |
May | 3962.60 | 22-MAY-15:20 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.84 |
June | 5016.37 | 13-JUN-16:00 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 8.54 | 0.00 |
July | 4825.49 | 10-JUL-15:00 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.59 |
August | 4436.03 | 14-AUG-16:00 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 6.01 | 0.00 |
September | 3943.28 | 13-SEP-15:30 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.92 |
October | 2114.59 | 06-OCT-15:40 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.95 |
November | 1389.29 | 10-NOV-15:30 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.65 |
December | 1174.68 | 21-DEC-15:10 | 1272.23 | 1121.62 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.15 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1174.68 | 1272.23 | 647.98 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 5016.37 | 1272.23 | 1121.62 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 8.54 | 55.78 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1455.88 | 20-JAN-10:00 | 1610.86 | 820.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 1575.29 | 17-FEB-10:00 | 1610.86 | 820.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 1496.48 | 25-MAR-09:50 | 0.00 | 136.74 | 504.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 10538.41 | 30-APR-10:43 | 169.56 | 91.16 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.19 |
May | 12260.42 | 21-MAY-08:43 | 169.56 | 91.16 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69.42 |
June | 11960.78 | 11-JUN-09:23 | 169.56 | 91.16 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.63 |
July | 13576.42 | 23-JUL-08:42 | 211.95 | 113.95 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.51 |
August | 11321.47 | 13-AUG-09:53 | 169.56 | 91.16 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 66.33 |
September | 6994.50 | 12-SEP-09:00 | 805.43 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.32 |
October | 4096.06 | 03-OCT-09:00 | 805.43 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.61 |
November | 1435.27 | 03-NOV-10:30 | 805.43 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.82 |
December | 1278.32 | 06-DEC-10:00 | 805.43 | 410.22 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1278.32 | 0.00 | 91.16 | 504.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 13576.42 | 1610.86 | 820.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.63 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 7211.07 | 20-JAN-12:00 | 1272.23 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 8431.12 | 17-FEB-13:40 | 2544.47 | 1295.96 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.16 |
March | 4578.83 | 28-MAR-12:05 | 5088.93 | 2591.92 | 5740.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.90 |
April | 18898.70 | 30-APR-13:22 | 334.80 | 179.99 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.21 |
May | 11434.44 | 21-MAY-13:43 | 267.84 | 143.99 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 135.11 |
June | 9429.04 | 13-JUN-13:10 | 1306.65 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 | 0.00 |
July | 17913.15 | 23-JUL-12:43 | 267.84 | 143.99 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.60 |
August | 18725.84 | 13-AUG-13:13 | 267.84 | 143.99 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80.24 |
September | 19620.75 | 24-SEP-13:12 | 334.80 | 179.99 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.55 |
October | 11625.19 | 03-OCT-13:10 | 1306.65 | 647.98 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.91 |
November | 7666.44 | 03-NOV-12:25 | 2544.47 | 1295.96 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.60 |
December | 5945.77 | 18-DEC-13:25 | 2544.47 | 1295.96 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.24 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 4578.83 | 267.84 | 143.99 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 19620.75 | 5088.93 | 2591.92 | 5740.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 | 135.11 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1643.94 | 19-JAN-15:50 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 2788.49 | 27-FEB-16:30 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 3069.75 | 23-MAR-16:40 | 254.33 | 227.89 | 504.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.83 |
April | 13329.47 | 30-APR-16:42 | 211.94 | 113.94 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.43 |
May | 14806.26 | 21-MAY-17:02 | 0.00 | 136.73 | 1466.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.61 |
June | 13238.41 | 25-JUN-16:52 | 211.94 | 113.94 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.69 |
July | 14338.86 | 30-JUL-16:22 | 211.94 | 113.94 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 194.75 |
August | 12545.15 | 20-AUG-16:12 | 211.94 | 113.94 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.68 |
September | 11422.67 | 10-SEP-16:12 | 169.55 | 91.15 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.15 |
October | 5357.63 | 03-OCT-15:40 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.37 |
November | 1806.11 | 10-NOV-15:40 | 805.38 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.37 |
December | 1382.18 | 21-DEC-14:40 | 827.17 | 410.20 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.43 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1382.18 | 0.00 | 91.15 | 504.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 14806.26 | 827.17 | 410.20 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 194.75 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
January | 0.105119E+12 | 89717.68 | 20-JAN-16:00 | 0.642540E+11 | 174236.85 | 10-JAN-07:10 |
February | 0.936495E+11 | 83834.27 | 07-FEB-16:00 | 0.422913E+11 | 148287.88 | 13-FEB-07:10 |
March | 0.106571E+12 | 81467.86 | 15-MAR-07:19 | 0.364633E+11 | 132132.32 | 06-MAR-07:10 |
April | 0.998779E+11 | 107181.92 | 28-APR-15:20 | 0.525472E+10 | 83157.80 | 03-APR-06:10 |
May | 0.106093E+12 | 116423.32 | 22-MAY-15:09 | 0.263728E+10 | 45985.62 | 05-MAY-06:10 |
June | 0.110157E+12 | 136967.67 | 13-JUN-15:30 | 0.745785E+09 | 17032.07 | 08-JUN-06:10 |
July | 0.112798E+12 | 133821.91 | 21-JUL-15:39 | 0.280592E+09 | 14304.35 | 03-JUL-06:19 |
August | 0.122927E+12 | 130565.42 | 14-AUG-15:39 | 0.256252E+09 | 14858.13 | 24-AUG-06:19 |
September | 0.107563E+12 | 121012.64 | 13-SEP-15:20 | 0.865131E+09 | 37919.71 | 21-SEP-06:10 |
October | 0.103430E+12 | 88522.18 | 06-OCT-15:30 | 0.103903E+11 | 101042.70 | 23-OCT-06:10 |
November | 0.102294E+12 | 89718.35 | 17-NOV-16:40 | 0.334399E+11 | 138182.72 | 20-NOV-07:10 |
December | 0.103978E+12 | 89634.01 | 29-DEC-16:49 | 0.669867E+11 | 162801.15 | 26-DEC-07:19 |
Annual Sum or Average | 0.127446E+13 | 0.263865E+12 | ||||
Minimum of Months | 0.936495E+11 | 81467.86 | 0.256252E+09 | 14304.35 | ||
Maximum of Months | 0.122927E+12 | 136967.67 | 0.669867E+11 | 174236.85 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [J] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [J] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.265879E+11 | 0.633936E+10 | 0.605851E+11 | 0.225898E+10 | 0.412390E+10 | 0.289343E+09 | 0.00 | 10264.25 | 0.00 | 0.00 | 0.00 | 0.493470E+10 | 0.00 |
February | 0.233292E+11 | 0.494283E+10 | 0.548702E+11 | 0.204971E+10 | 0.375506E+10 | 0.193605E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.450880E+10 | 0.00 |
March | 0.271542E+11 | 0.444618E+10 | 0.627783E+11 | 0.235662E+10 | 0.438141E+10 | 0.167437E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.528733E+10 | 0.00 |
April | 0.237596E+11 | 0.339694E+10 | 0.586172E+11 | 0.219320E+10 | 0.597963E+10 | 37052190.69 | 0.00 | 0.120926E+10 | 0.00 | 0.00 | 0.00 | 0.468496E+10 | 0.00 |
May | 0.254473E+11 | 0.287507E+10 | 0.616817E+11 | 0.230704E+10 | 0.705812E+10 | 27320531.85 | 0.00 | 0.180517E+10 | 0.00 | 0.00 | 0.00 | 0.489083E+10 | 0.00 |
June | 0.252596E+11 | 0.251338E+10 | 0.604966E+11 | 0.226921E+10 | 0.891971E+10 | 17322557.85 | 0.00 | 0.595134E+10 | 0.00 | 0.00 | 0.00 | 0.473008E+10 | 0.00 |
July | 0.236022E+11 | 0.270668E+10 | 0.597911E+11 | 0.222998E+10 | 0.993103E+10 | 14068718.22 | 0.00 | 0.101339E+11 | 0.00 | 0.00 | 0.00 | 0.438893E+10 | 0.00 |
August | 0.265587E+11 | 0.320001E+10 | 0.627783E+11 | 0.235612E+10 | 0.105602E+11 | 14208940.94 | 0.00 | 0.126647E+11 | 0.00 | 0.00 | 0.00 | 0.479463E+10 | 0.00 |
September | 0.239414E+11 | 0.386819E+10 | 0.585950E+11 | 0.219214E+10 | 0.829261E+10 | 17020670.65 | 0.00 | 0.629444E+10 | 0.00 | 0.00 | 0.00 | 0.436238E+10 | 0.00 |
October | 0.256426E+11 | 0.502585E+10 | 0.605962E+11 | 0.225951E+10 | 0.500093E+10 | 58591991.30 | 0.00 | 0.249726E+09 | 0.00 | 0.00 | 0.00 | 0.459694E+10 | 0.00 |
November | 0.263283E+11 | 0.583860E+10 | 0.591197E+11 | 0.220161E+10 | 0.401025E+10 | 0.153816E+09 | 0.00 | 2669221.48 | 0.00 | 0.00 | 0.00 | 0.463885E+10 | 0.00 |
December | 0.263637E+11 | 0.660206E+10 | 0.597800E+11 | 0.223035E+10 | 0.397995E+10 | 0.301615E+09 | 0.00 | 29894.35 | 0.00 | 0.00 | 0.00 | 0.471981E+10 | 0.00 |
Annual Sum or Average | 0.303975E+12 | 0.517552E+11 | 0.719689E+12 | 0.269045E+11 | 0.759928E+11 | 0.129140E+10 | 0.00 | 0.383113E+11 | 0.00 | 0.00 | 0.00 | 0.565382E+11 | 0.00 |
Minimum of Months | 0.233292E+11 | 0.251338E+10 | 0.548702E+11 | 0.204971E+10 | 0.375506E+10 | 14068718.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.436238E+10 | 0.00 |
Maximum of Months | 0.271542E+11 | 0.660206E+10 | 0.627783E+11 | 0.235662E+10 | 0.105602E+11 | 0.301615E+09 | 0.00 | 0.126647E+11 | 0.00 | 0.00 | 0.00 | 0.528733E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
January | 0.00 | 0.00 | 0.642540E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.422913E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.364633E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.525472E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.263728E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.745785E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.280592E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.256252E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.865131E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.103903E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.334399E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.669867E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.263865E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.256252E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.669867E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | EXTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY {Maximum} [W] | PUMPS:ELECTRICITY {TIMESTAMP} | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 32642.50 | 02-JAN-08:09 | 5686.19 | 01-JAN-06:10 | 41699.26 | 02-JAN-08:09 | 1410.29 | 02-JAN-08:20 | 7544.43 | 02-JAN-07:10 | 552.07 | 10-JAN-07:30 | 0.00 | 01-JAN-00:10 |
February | 32642.50 | 01-FEB-08:09 | 5686.19 | 01-FEB-06:10 | 41699.26 | 01-FEB-08:09 | 1410.29 | 01-FEB-17:10 | 4951.37 | 13-FEB-07:10 | 518.43 | 17-FEB-07:10 | 0.00 | 01-FEB-00:10 |
March | 31270.76 | 15-MAR-07:10 | 5686.19 | 01-MAR-06:10 | 41699.26 | 01-MAR-08:09 | 1410.29 | 02-MAR-08:09 | 4748.64 | 06-MAR-07:10 | 503.01 | 06-MAR-07:10 | 0.00 | 01-MAR-00:10 |
April | 30491.18 | 10-APR-07:10 | 5686.19 | 01-APR-05:10 | 41699.26 | 03-APR-07:10 | 1410.29 | 04-APR-07:10 | 16867.74 | 28-APR-15:20 | 343.05 | 03-APR-06:10 | 0.00 | 01-APR-00:10 |
May | 26300.01 | 04-MAY-07:10 | 3328.83 | 01-MAY-19:19 | 41699.26 | 01-MAY-07:10 | 1410.29 | 01-MAY-12:09 | 16324.60 | 23-MAY-15:20 | 204.78 | 05-MAY-06:10 | 0.00 | 01-MAY-00:10 |
June | 25801.04 | 14-JUN-07:10 | 3328.83 | 01-JUN-19:00 | 41699.26 | 01-JUN-07:10 | 1410.29 | 02-JUN-11:09 | 22047.46 | 13-JUN-15:30 | 116.79 | 08-JUN-06:10 | 0.00 | 01-JUN-00:10 |
July | 26180.04 | 07-JUL-07:10 | 3328.83 | 01-JUL-20:19 | 41699.26 | 03-JUL-07:10 | 1410.29 | 03-JUL-11:09 | 21104.08 | 21-JUL-15:39 | 90.60 | 05-JUL-06:49 | 0.00 | 01-JUL-00:10 |
August | 28290.68 | 22-AUG-07:30 | 5686.19 | 14-AUG-05:10 | 41699.26 | 01-AUG-07:10 | 1410.29 | 01-AUG-07:19 | 20903.78 | 14-AUG-15:30 | 90.54 | 24-AUG-06:40 | 0.00 | 01-AUG-00:10 |
September | 28620.49 | 08-SEP-07:30 | 5686.19 | 01-SEP-05:10 | 41699.26 | 01-SEP-07:10 | 1410.29 | 08-SEP-11:09 | 19409.48 | 12-SEP-15:20 | 198.92 | 21-SEP-06:10 | 0.00 | 01-SEP-00:10 |
October | 32642.50 | 16-OCT-07:10 | 5686.19 | 01-OCT-05:10 | 41699.26 | 02-OCT-07:10 | 1410.29 | 04-OCT-07:10 | 10399.03 | 03-OCT-14:50 | 422.23 | 23-OCT-06:10 | 0.00 | 01-OCT-00:10 |
November | 32642.50 | 01-NOV-07:10 | 5686.19 | 01-NOV-05:10 | 41699.26 | 01-NOV-07:10 | 1410.29 | 01-NOV-07:10 | 5363.97 | 27-NOV-07:10 | 505.85 | 27-NOV-07:10 | 0.00 | 01-NOV-00:10 |
December | 32642.50 | 01-DEC-08:09 | 5686.19 | 01-DEC-06:10 | 41699.26 | 01-DEC-08:09 | 1410.29 | 01-DEC-08:09 | 6379.51 | 26-DEC-07:10 | 533.54 | 26-DEC-07:19 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 25801.04 | 3328.83 | 41699.26 | 1410.29 | 4748.64 | 90.54 | 0.00 | |||||||
Maximum of Months | 32642.50 | 5686.19 | 41699.26 | 1410.29 | 22047.46 | 552.07 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 17.11 | 09-JAN-05:49 | 0.00 | 0.00 | 0.00 | 6664.39 | 30-JAN-12:00 | 0.00 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 6667.55 | 13-FEB-12:30 | 0.00 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 6664.44 | 01-MAR-12:30 | 0.00 |
April | 16586.37 | 28-APR-14:00 | 0.00 | 0.00 | 0.00 | 6608.33 | 04-APR-11:20 | 0.00 |
May | 27370.62 | 22-MAY-14:00 | 0.00 | 0.00 | 0.00 | 6267.37 | 01-MAY-11:20 | 0.00 |
June | 41647.56 | 13-JUN-15:00 | 0.00 | 0.00 | 0.00 | 6220.35 | 01-JUN-11:50 | 0.00 |
July | 39634.48 | 21-JUL-15:00 | 0.00 | 0.00 | 0.00 | 6142.76 | 03-JUL-11:39 | 0.00 |
August | 36542.91 | 14-AUG-15:00 | 0.00 | 0.00 | 0.00 | 5834.20 | 31-AUG-11:00 | 0.00 |
September | 28839.67 | 13-SEP-15:20 | 0.00 | 0.00 | 0.00 | 6130.25 | 29-SEP-11:20 | 0.00 |
October | 7784.91 | 07-OCT-14:00 | 0.00 | 0.00 | 0.00 | 6220.56 | 31-OCT-11:50 | 0.00 |
November | 1982.88 | 24-NOV-11:00 | 0.00 | 0.00 | 0.00 | 6266.19 | 30-NOV-12:50 | 0.00 |
December | 26.28 | 18-DEC-05:19 | 0.00 | 0.00 | 0.00 | 6607.35 | 28-DEC-12:50 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 5834.20 | 0.00 | ||
Maximum of Months | 41647.56 | 0.00 | 0.00 | 0.00 | 6667.55 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 89717.68 | 20-JAN-16:00 | 32642.50 | 41670.51 | 5686.19 | 1410.29 | 3288.46 | 44.42 | 0.00 | 0.00 | 0.00 |
February | 83834.27 | 07-FEB-16:00 | 32642.50 | 41670.51 | 0.00 | 1410.29 | 3091.28 | 6.85 | 0.00 | 0.00 | 0.00 |
March | 81467.86 | 15-MAR-07:19 | 30940.97 | 41699.26 | 0.00 | 1410.29 | 2945.33 | 289.82 | 0.00 | 0.00 | 0.00 |
April | 107181.92 | 28-APR-15:20 | 25681.07 | 41670.51 | 0.00 | 1410.29 | 16867.74 | 6.85 | 0.00 | 16567.92 | 0.00 |
May | 116423.32 | 22-MAY-15:09 | 25681.07 | 41670.51 | 0.00 | 1410.29 | 16178.72 | 6.85 | 0.00 | 26851.18 | 0.00 |
June | 136967.67 | 13-JUN-15:30 | 25681.07 | 41670.51 | 0.00 | 1410.29 | 22047.46 | 6.91 | 0.00 | 41522.26 | 0.00 |
July | 133821.91 | 21-JUL-15:39 | 25681.07 | 41670.51 | 0.00 | 1410.29 | 21104.08 | 6.85 | 0.00 | 39341.26 | 0.00 |
August | 130565.42 | 14-AUG-15:39 | 25681.07 | 41670.51 | 0.00 | 1410.29 | 20810.15 | 6.89 | 0.00 | 36383.35 | 0.00 |
September | 121012.64 | 13-SEP-15:20 | 25681.07 | 41670.51 | 0.00 | 1410.29 | 18795.65 | 6.89 | 0.00 | 28839.67 | 0.00 |
October | 88522.18 | 06-OCT-15:30 | 25681.07 | 41670.51 | 0.00 | 1410.29 | 9154.72 | 6.85 | 0.00 | 5986.07 | 0.00 |
November | 89718.35 | 17-NOV-16:40 | 32642.50 | 41670.51 | 5686.19 | 1410.29 | 3325.29 | 20.77 | 0.00 | 0.00 | 0.00 |
December | 89634.01 | 29-DEC-16:49 | 32642.50 | 41670.51 | 5686.19 | 1410.29 | 2962.44 | 265.35 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | ||||||||||
Minimum of Months | 81467.86 | 25681.07 | 41670.51 | 0.00 | 1410.29 | 2945.33 | 6.85 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 136967.67 | 32642.50 | 41699.26 | 5686.19 | 1410.29 | 22047.46 | 289.82 | 0.00 | 41522.26 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [] | COGENERATION:NATURALGAS [] | |
January | 0.00 | 0.00 | 174236.85 | 10-JAN-07:10 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 148287.88 | 13-FEB-07:10 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 132132.32 | 06-MAR-07:10 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 83157.80 | 03-APR-06:10 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 45985.62 | 05-MAY-06:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 17032.07 | 08-JUN-06:10 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 14304.35 | 03-JUL-06:19 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 14858.13 | 24-AUG-06:19 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 37919.71 | 21-SEP-06:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 101042.70 | 23-OCT-06:10 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 138182.72 | 20-NOV-07:10 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 162801.15 | 26-DEC-07:19 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 14304.35 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 174236.85 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.83 | 19.80 | 0.83 | 19.80 | 0.00 | 19.80 | 0.00 | 19.80 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.83 | 19.80 | 0.83 | 19.80 | 0.00 | 19.80 | 0.00 | 19.80 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.83 | 19.80 | 0.83 | 19.80 | 0.00 | 19.80 | 0.00 | 19.80 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.33 | 19.61 | 1.33 | 19.61 | 0.00 | 19.61 | 0.00 | 19.61 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 1.00 | 19.21 | 1.00 | 19.21 | 0.00 | 19.21 | 0.00 | 19.21 |
Annual Sum or Average | 2.33 | 19.44 | 2.33 | 19.44 | 0.00 | 19.44 | 0.00 | 19.44 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1.33 | 19.61 | 1.33 | 19.61 | 0.00 | 19.61 | 0.00 | 19.61 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 8.33 | 18.60 | 6.67 | 18.90 | 0.00 | 18.90 | 0.00 | 18.90 |
February | 1.67 | 19.12 | 1.50 | 19.22 | 0.00 | 19.22 | 0.00 | 19.22 |
March | 0.50 | 19.10 | 0.50 | 19.10 | 0.00 | 19.10 | 0.00 | 19.10 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 1.50 | 19.16 | 1.33 | 19.28 | 0.00 | 19.28 | 0.00 | 19.28 |
December | 8.00 | 19.13 | 7.33 | 19.26 | 0.00 | 19.26 | 0.00 | 19.26 |
Annual Sum or Average | 20.00 | 18.91 | 17.33 | 19.11 | 0.00 | 19.11 | 0.00 | 19.11 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 8.33 | 19.16 | 7.33 | 19.28 | 0.00 | 19.28 | 0.00 | 19.28 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 3.17 | 18.50 | 2.33 | 18.80 | 0.00 | 18.80 | 0.00 | 18.80 |
February | 0.67 | 18.79 | 0.50 | 19.02 | 0.00 | 19.02 | 0.00 | 19.02 |
March | 0.17 | 19.14 | 0.17 | 19.14 | 0.00 | 19.14 | 0.00 | 19.14 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 27.91 | 1.00 | 27.91 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 27.49 | 0.67 | 27.49 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 27.63 | 1.83 | 27.63 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 3.33 | 27.90 | 3.33 | 27.90 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 27.60 | 2.00 | 27.60 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.50 | 18.51 | 0.33 | 18.78 | 0.00 | 18.78 | 0.00 | 18.78 |
December | 3.67 | 18.81 | 3.00 | 19.09 | 0.00 | 19.09 | 0.00 | 19.09 |
Annual Sum or Average | 8.17 | 18.68 | 6.33 | 18.96 | 8.83 | 22.28 | 8.83 | 23.78 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 3.67 | 19.14 | 3.00 | 19.14 | 3.33 | 27.91 | 3.33 | 27.91 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 2.00 | 18.89 | 1.50 | 19.17 | 0.00 | 19.17 | 0.00 | 19.17 |
February | 0.17 | 19.35 | 0.17 | 19.35 | 0.00 | 19.35 | 0.00 | 19.35 |
March | 0.17 | 19.16 | 0.17 | 19.16 | 0.00 | 19.16 | 0.00 | 19.16 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 28.20 | 1.67 | 28.20 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.31 | 0.83 | 27.31 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 27.67 | 3.00 | 27.67 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 4.33 | 27.77 | 4.33 | 27.77 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 27.80 | 3.83 | 27.80 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.55 | 0.83 | 27.55 |
November | 0.17 | 18.96 | 0.17 | 18.96 | 0.00 | 18.96 | 0.00 | 18.96 |
December | 2.17 | 19.12 | 2.00 | 19.20 | 0.00 | 19.20 | 0.00 | 19.20 |
Annual Sum or Average | 4.67 | 19.03 | 4.00 | 19.18 | 14.50 | 24.56 | 14.50 | 25.79 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2.17 | 19.35 | 2.00 | 19.35 | 4.33 | 28.20 | 4.33 | 28.20 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 2.83 | 18.28 | 2.00 | 18.66 | 0.00 | 18.66 | 0.00 | 18.66 |
February | 0.67 | 18.81 | 0.50 | 19.05 | 0.00 | 19.05 | 0.00 | 19.05 |
March | 0.17 | 19.16 | 0.17 | 19.16 | 0.00 | 19.16 | 0.00 | 19.16 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.50 | 28.28 | 1.00 | 28.29 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 2.50 | 27.83 | 1.33 | 27.82 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 28.06 | 1.33 | 28.07 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 28.16 | 2.67 | 28.17 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 | 28.04 | 2.33 | 28.08 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.75 | 0.83 | 27.75 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.67 | 18.21 | 0.33 | 18.53 | 0.00 | 18.53 | 0.00 | 18.53 |
December | 3.17 | 18.80 | 2.67 | 19.07 | 0.00 | 19.07 | 0.00 | 19.07 |
Annual Sum or Average | 7.50 | 18.56 | 5.67 | 18.88 | 17.17 | 24.07 | 9.50 | 25.03 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 3.17 | 19.16 | 2.67 | 19.16 | 5.67 | 28.28 | 2.67 | 28.29 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 2.33 | 19.40 | 2.17 | 19.48 | 0.00 | 19.48 | 0.00 | 19.48 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.17 | 19.38 | 0.17 | 19.38 | 0.00 | 19.38 | 0.00 | 19.38 |
Annual Sum or Average | 2.50 | 19.39 | 2.33 | 19.47 | 0.00 | 19.47 | 0.00 | 19.47 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2.33 | 19.40 | 2.17 | 19.48 | 0.00 | 19.48 | 0.00 | 19.48 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.33 | 19.87 | 0.33 | 19.87 | 0.00 | 19.87 | 0.00 | 19.87 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.54 | 0.83 | 27.54 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 27.42 | 0.33 | 27.42 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 27.67 | 2.33 | 27.67 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 27.48 | 0.67 | 27.48 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.33 | 19.87 | 0.33 | 19.87 | 4.17 | 26.53 | 4.17 | 27.02 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.33 | 19.87 | 0.33 | 19.87 | 2.33 | 27.67 | 2.33 | 27.67 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 67.33 | 18.28 | 67.33 | 18.28 | 0.00 | 18.28 | 0.00 | 18.28 |
February | 54.17 | 18.73 | 54.17 | 18.73 | 0.00 | 18.73 | 0.00 | 18.73 |
March | 65.00 | 18.80 | 65.00 | 18.80 | 0.00 | 18.80 | 0.00 | 18.80 |
April | 20.17 | 19.22 | 20.17 | 19.22 | 1.33 | 19.49 | 1.33 | 19.75 |
May | 15.50 | 19.70 | 15.50 | 19.70 | 0.00 | 19.70 | 0.00 | 19.70 |
June | 1.67 | 20.17 | 1.67 | 20.17 | 0.00 | 20.17 | 0.00 | 20.17 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 27.46 | 0.67 | 27.46 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 27.50 | 2.33 | 27.50 |
September | 2.83 | 20.02 | 2.83 | 20.02 | 2.33 | 22.25 | 2.33 | 23.47 |
October | 25.00 | 19.44 | 25.00 | 19.44 | 1.00 | 19.60 | 1.00 | 19.75 |
November | 51.67 | 19.01 | 51.67 | 19.01 | 0.00 | 19.01 | 0.00 | 19.01 |
December | 64.17 | 18.29 | 64.17 | 18.29 | 0.00 | 18.29 | 0.00 | 18.29 |
Annual Sum or Average | 367.50 | 18.75 | 367.50 | 18.75 | 7.67 | 18.84 | 7.67 | 18.93 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.28 | 0.00 | 18.28 |
Maximum of Months | 67.33 | 20.17 | 67.33 | 20.17 | 2.33 | 27.50 | 2.33 | 27.50 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.33 | 19.82 | 0.33 | 19.82 | 0.00 | 19.82 | 0.00 | 19.82 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 27.84 | 0.67 | 27.80 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.65 | 0.33 | 27.62 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 27.69 | 1.00 | 27.66 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 27.76 | 1.50 | 27.77 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 27.62 | 1.50 | 27.62 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.33 | 19.82 | 0.33 | 19.82 | 10.00 | 27.22 | 5.00 | 27.37 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.33 | 19.82 | 0.33 | 19.82 | 4.00 | 27.84 | 1.50 | 27.80 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 2.17 | 19.43 | 2.00 | 19.52 | 0.00 | 19.52 | 0.00 | 19.52 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.83 | 19.39 | 0.83 | 19.39 | 0.00 | 19.39 | 0.00 | 19.39 |
Annual Sum or Average | 3.00 | 19.42 | 2.83 | 19.48 | 0.00 | 19.48 | 0.00 | 19.48 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2.17 | 19.43 | 2.00 | 19.52 | 0.00 | 19.52 | 0.00 | 19.52 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.83 | 19.08 | 0.67 | 19.29 | 0.00 | 19.29 | 0.00 | 19.29 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 27.96 | 1.17 | 27.96 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 27.63 | 1.17 | 27.63 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 27.72 | 2.33 | 27.72 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 27.97 | 3.17 | 27.97 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 27.66 | 3.00 | 27.66 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 27.49 | 2.00 | 27.49 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.33 | 19.23 | 0.33 | 19.23 | 0.00 | 19.23 | 0.00 | 19.23 |
Annual Sum or Average | 1.17 | 19.12 | 1.00 | 19.27 | 12.83 | 26.52 | 12.83 | 27.09 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.83 | 19.23 | 0.67 | 19.29 | 3.17 | 27.97 | 3.17 | 27.97 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.17 | 19.31 | 0.17 | 19.31 | 0.00 | 19.31 | 0.00 | 19.31 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.27 | 0.17 | 27.27 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 28.05 | 1.83 | 28.05 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 27.31 | 0.33 | 27.31 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.27 | 0.17 | 27.27 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 2.67 | 27.62 | 2.67 | 27.62 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 4.50 | 27.73 | 4.50 | 27.73 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 4.83 | 27.79 | 4.83 | 27.79 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 27.67 | 1.17 | 27.67 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 27.34 | 0.33 | 27.34 |
December | 0.17 | 19.33 | 0.17 | 19.33 | 0.00 | 19.33 | 0.00 | 19.33 |
Annual Sum or Average | 0.33 | 19.32 | 0.33 | 19.32 | 16.00 | 27.40 | 16.00 | 27.56 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.17 | 19.33 | 0.17 | 19.33 | 4.83 | 28.05 | 4.83 | 28.05 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.83 | 19.29 | 0.67 | 19.53 | 0.00 | 19.53 | 0.00 | 19.53 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.50 | 28.20 | 1.00 | 28.16 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 27.89 | 1.33 | 27.91 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 2.50 | 28.12 | 1.33 | 28.12 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 5.33 | 28.11 | 2.67 | 28.12 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 27.93 | 2.50 | 27.96 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.79 | 0.83 | 27.79 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.33 | 19.23 | 0.33 | 19.23 | 0.00 | 19.23 | 0.00 | 19.23 |
Annual Sum or Average | 1.17 | 19.28 | 1.00 | 19.43 | 16.33 | 27.02 | 9.67 | 27.37 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.83 | 19.29 | 0.67 | 19.53 | 5.33 | 28.20 | 2.67 | 28.16 |
Report: ComfortReportSimple55Monthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 466.50 | 23.40 | 12.00 | 23.34 | 12.00 | 23.28 |
February | 426.17 | 23.80 | 0.00 | 23.80 | 0.00 | 23.80 |
March | 469.33 | 23.81 | 0.00 | 23.81 | 0.00 | 23.81 |
April | 94.33 | 23.95 | 62.83 | 24.66 | 0.00 | 24.66 |
May | 10.50 | 24.01 | 158.33 | 25.06 | 0.00 | 25.06 |
June | 0.00 | 0.00 | 344.17 | 24.58 | 0.00 | 24.58 |
July | 0.00 | 0.00 | 411.33 | 24.57 | 0.00 | 24.57 |
August | 0.00 | 0.00 | 419.17 | 24.45 | 0.00 | 24.45 |
September | 0.00 | 0.00 | 301.00 | 24.62 | 0.00 | 24.62 |
October | 96.17 | 23.76 | 76.50 | 24.48 | 0.00 | 24.48 |
November | 304.83 | 23.78 | 1.50 | 23.78 | 0.00 | 23.78 |
December | 495.33 | 23.53 | 0.00 | 23.53 | 0.00 | 23.53 |
Annual Sum or Average | 2363.17 | 23.67 | 1786.83 | 24.09 | 12.00 | 24.08 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 23.34 | 0.00 | 23.28 |
Maximum of Months | 495.33 | 24.01 | 419.17 | 25.06 | 12.00 | 25.06 |
Report: ComfortReportSimple55Monthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 21.80 | 41.83 | 21.68 | 41.83 | 21.57 |
February | 454.00 | 22.13 | 1.67 | 22.13 | 1.67 | 22.12 |
March | 514.00 | 22.36 | 1.33 | 22.36 | 1.33 | 22.35 |
April | 357.50 | 23.44 | 3.17 | 23.45 | 0.00 | 23.45 |
May | 235.50 | 23.45 | 32.17 | 23.57 | 0.00 | 23.57 |
June | 79.33 | 23.53 | 174.83 | 24.11 | 0.00 | 24.11 |
July | 56.17 | 23.43 | 255.00 | 24.16 | 0.00 | 24.16 |
August | 28.83 | 23.52 | 235.67 | 24.22 | 0.00 | 24.22 |
September | 139.67 | 23.40 | 103.83 | 23.80 | 0.00 | 23.80 |
October | 426.00 | 22.97 | 0.00 | 22.97 | 0.00 | 22.97 |
November | 489.00 | 22.36 | 1.67 | 22.35 | 1.67 | 22.34 |
December | 497.00 | 21.65 | 53.33 | 21.56 | 53.33 | 21.49 |
Annual Sum or Average | 3779.00 | 22.49 | 904.50 | 22.77 | 99.83 | 22.72 |
Minimum of Months | 28.83 | 21.65 | 0.00 | 21.56 | 0.00 | 21.49 |
Maximum of Months | 514.00 | 23.53 | 255.00 | 24.22 | 53.33 | 24.22 |
Report: ComfortReportSimple55Monthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 21.04 | 188.33 | 20.82 | 188.33 | 20.70 |
February | 454.00 | 21.28 | 102.83 | 21.08 | 102.83 | 20.93 |
March | 514.00 | 21.59 | 61.83 | 21.46 | 61.83 | 21.35 |
April | 407.33 | 22.92 | 1.17 | 22.92 | 1.17 | 22.91 |
May | 344.83 | 23.08 | 31.33 | 23.17 | 0.00 | 23.17 |
June | 163.50 | 23.27 | 126.50 | 23.66 | 0.00 | 23.66 |
July | 138.67 | 23.25 | 214.67 | 23.85 | 0.00 | 23.85 |
August | 136.00 | 23.30 | 173.00 | 23.78 | 0.00 | 23.78 |
September | 268.00 | 23.07 | 66.67 | 23.28 | 0.00 | 23.28 |
October | 484.67 | 22.20 | 10.00 | 22.16 | 10.00 | 22.12 |
November | 489.00 | 21.43 | 78.67 | 21.29 | 78.67 | 21.17 |
December | 497.00 | 20.88 | 203.50 | 20.67 | 203.50 | 20.55 |
Annual Sum or Average | 4399.00 | 21.96 | 1258.50 | 22.00 | 646.33 | 21.82 |
Minimum of Months | 136.00 | 20.88 | 1.17 | 20.67 | 0.00 | 20.55 |
Maximum of Months | 514.00 | 23.30 | 214.67 | 23.85 | 203.50 | 23.85 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.32 | 353.50 | 20.19 | 353.50 | 20.13 |
February | 454.00 | 20.46 | 272.67 | 20.29 | 272.67 | 20.22 |
March | 514.00 | 20.88 | 224.17 | 20.71 | 224.17 | 20.62 |
April | 429.33 | 22.19 | 48.50 | 22.03 | 45.00 | 21.87 |
May | 402.00 | 22.53 | 37.33 | 22.61 | 5.33 | 22.58 |
June | 206.83 | 22.97 | 135.00 | 23.44 | 0.00 | 23.44 |
July | 175.33 | 23.04 | 197.50 | 23.65 | 0.00 | 23.65 |
August | 219.00 | 22.99 | 154.17 | 23.43 | 0.00 | 23.43 |
September | 344.67 | 22.48 | 44.67 | 22.65 | 0.83 | 22.65 |
October | 500.67 | 21.35 | 97.67 | 21.14 | 97.67 | 21.00 |
November | 489.00 | 20.58 | 250.33 | 20.40 | 250.33 | 20.31 |
December | 497.00 | 20.16 | 399.33 | 20.07 | 399.33 | 20.03 |
Annual Sum or Average | 4733.83 | 21.37 | 2214.83 | 21.28 | 1648.83 | 21.05 |
Minimum of Months | 175.33 | 20.16 | 37.33 | 20.07 | 0.00 | 20.03 |
Maximum of Months | 514.00 | 23.04 | 399.33 | 23.65 | 399.33 | 23.65 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.42 | 335.83 | 20.28 | 335.83 | 20.23 |
February | 454.00 | 20.64 | 242.83 | 20.46 | 242.83 | 20.38 |
March | 514.00 | 20.91 | 200.67 | 20.75 | 200.67 | 20.66 |
April | 315.33 | 22.30 | 77.50 | 22.44 | 29.33 | 22.33 |
May | 286.83 | 22.43 | 121.33 | 22.95 | 5.83 | 22.92 |
June | 182.17 | 22.96 | 235.17 | 23.73 | 7.50 | 23.79 |
July | 145.50 | 23.29 | 291.67 | 24.08 | 13.50 | 24.17 |
August | 170.17 | 23.07 | 277.83 | 23.82 | 8.00 | 23.87 |
September | 229.83 | 22.38 | 178.00 | 23.24 | 1.67 | 23.23 |
October | 451.17 | 21.30 | 85.33 | 21.15 | 80.50 | 21.01 |
November | 489.00 | 20.65 | 217.67 | 20.47 | 217.67 | 20.37 |
December | 497.00 | 20.22 | 384.83 | 20.12 | 384.83 | 20.08 |
Annual Sum or Average | 4237.00 | 21.30 | 2648.67 | 21.55 | 1528.17 | 21.32 |
Minimum of Months | 145.50 | 20.22 | 77.50 | 20.12 | 1.67 | 20.08 |
Maximum of Months | 514.00 | 23.29 | 384.83 | 24.08 | 384.83 | 24.17 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 470.83 | 20.79 | 270.33 | 20.60 | 264.83 | 20.49 |
February | 410.33 | 21.00 | 200.17 | 20.83 | 186.00 | 20.68 |
March | 502.50 | 21.10 | 187.83 | 20.90 | 187.83 | 20.78 |
April | 307.50 | 22.15 | 128.67 | 22.47 | 43.67 | 22.35 |
May | 324.67 | 22.23 | 127.00 | 22.71 | 14.50 | 22.63 |
June | 221.00 | 22.67 | 204.83 | 23.44 | 2.33 | 23.46 |
July | 189.50 | 22.99 | 243.83 | 23.79 | 13.00 | 23.88 |
August | 199.17 | 23.08 | 251.33 | 23.76 | 16.00 | 23.87 |
September | 237.67 | 22.60 | 211.67 | 23.46 | 14.50 | 23.56 |
October | 403.67 | 21.46 | 123.83 | 21.62 | 65.33 | 21.47 |
November | 457.67 | 20.95 | 194.00 | 20.80 | 182.00 | 20.65 |
December | 486.50 | 20.54 | 332.17 | 20.36 | 332.17 | 20.28 |
Annual Sum or Average | 4211.00 | 21.52 | 2475.67 | 21.78 | 1322.17 | 21.56 |
Minimum of Months | 189.50 | 20.54 | 123.83 | 20.36 | 2.33 | 20.28 |
Maximum of Months | 502.50 | 23.08 | 332.17 | 23.79 | 332.17 | 23.88 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.43 | 336.50 | 20.28 | 336.50 | 20.21 |
February | 447.33 | 20.68 | 246.33 | 20.47 | 246.33 | 20.37 |
March | 509.33 | 20.85 | 220.50 | 20.70 | 220.50 | 20.61 |
April | 380.00 | 21.98 | 101.67 | 22.10 | 49.00 | 21.98 |
May | 359.67 | 22.22 | 116.67 | 22.62 | 19.50 | 22.60 |
June | 231.33 | 22.73 | 204.17 | 23.46 | 7.50 | 23.52 |
July | 186.33 | 22.84 | 246.00 | 23.70 | 13.17 | 23.80 |
August | 239.00 | 22.89 | 199.83 | 23.51 | 12.50 | 23.60 |
September | 319.33 | 22.23 | 113.83 | 22.77 | 5.50 | 22.80 |
October | 467.17 | 21.20 | 105.17 | 21.11 | 88.17 | 20.97 |
November | 489.00 | 20.65 | 234.33 | 20.46 | 234.33 | 20.36 |
December | 497.00 | 20.19 | 402.33 | 20.10 | 402.33 | 20.07 |
Annual Sum or Average | 4627.50 | 21.31 | 2527.33 | 21.43 | 1635.33 | 21.22 |
Minimum of Months | 186.33 | 20.19 | 101.67 | 20.10 | 5.50 | 20.07 |
Maximum of Months | 509.33 | 22.89 | 402.33 | 23.70 | 402.33 | 23.80 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.63 | 303.50 | 20.52 | 303.50 | 20.47 |
February | 454.00 | 20.74 | 225.67 | 20.62 | 225.67 | 20.56 |
March | 514.00 | 21.02 | 160.67 | 20.90 | 160.67 | 20.83 |
April | 480.67 | 22.28 | 13.00 | 22.23 | 13.00 | 22.19 |
May | 449.17 | 22.76 | 2.83 | 22.76 | 0.00 | 22.76 |
June | 240.17 | 23.27 | 79.33 | 23.49 | 0.00 | 23.49 |
July | 168.33 | 23.34 | 147.17 | 23.71 | 0.00 | 23.71 |
August | 231.83 | 23.30 | 76.50 | 23.47 | 0.00 | 23.47 |
September | 366.83 | 22.96 | 21.33 | 23.02 | 0.00 | 23.02 |
October | 502.00 | 21.88 | 8.67 | 21.86 | 8.67 | 21.83 |
November | 489.00 | 21.07 | 107.17 | 20.96 | 107.17 | 20.89 |
December | 497.00 | 20.59 | 325.17 | 20.50 | 325.17 | 20.46 |
Annual Sum or Average | 4895.00 | 21.73 | 1471.00 | 21.61 | 1143.83 | 21.43 |
Minimum of Months | 168.33 | 20.59 | 2.83 | 20.50 | 0.00 | 20.46 |
Maximum of Months | 514.00 | 23.34 | 325.17 | 23.71 | 325.17 | 23.71 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.76 | 266.83 | 20.64 | 266.83 | 20.58 |
February | 454.00 | 20.97 | 154.67 | 20.83 | 154.67 | 20.75 |
March | 514.00 | 21.11 | 133.00 | 20.98 | 133.00 | 20.90 |
April | 317.17 | 22.75 | 35.67 | 22.91 | 4.50 | 22.89 |
May | 261.00 | 22.94 | 111.17 | 23.42 | 0.00 | 23.42 |
June | 129.83 | 23.24 | 228.33 | 23.97 | 0.50 | 23.97 |
July | 74.17 | 23.76 | 318.17 | 24.35 | 9.33 | 24.41 |
August | 85.67 | 23.44 | 307.83 | 24.11 | 3.17 | 24.14 |
September | 167.83 | 23.13 | 200.17 | 23.84 | 0.00 | 23.84 |
October | 442.67 | 22.01 | 11.67 | 22.02 | 7.00 | 21.99 |
November | 489.00 | 21.17 | 82.83 | 21.07 | 82.83 | 20.99 |
December | 497.00 | 20.64 | 302.17 | 20.54 | 302.17 | 20.49 |
Annual Sum or Average | 3934.33 | 21.61 | 2152.50 | 21.98 | 964.00 | 21.78 |
Minimum of Months | 74.17 | 20.64 | 11.67 | 20.54 | 0.00 | 20.49 |
Maximum of Months | 514.00 | 23.76 | 318.17 | 24.35 | 302.17 | 24.41 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 493.50 | 20.74 | 229.00 | 20.48 | 225.67 | 20.33 |
February | 437.33 | 20.97 | 127.67 | 20.73 | 123.33 | 20.55 |
March | 514.00 | 20.74 | 170.33 | 20.52 | 170.33 | 20.39 |
April | 362.33 | 22.11 | 73.33 | 22.26 | 28.33 | 22.15 |
May | 375.83 | 22.14 | 70.83 | 22.44 | 10.50 | 22.38 |
June | 279.50 | 22.54 | 137.33 | 23.15 | 0.00 | 23.15 |
July | 168.67 | 22.82 | 212.67 | 23.71 | 2.67 | 23.74 |
August | 138.83 | 22.95 | 273.33 | 23.87 | 8.17 | 23.93 |
September | 169.50 | 22.88 | 236.83 | 23.82 | 9.83 | 23.89 |
October | 394.50 | 21.76 | 71.50 | 21.98 | 18.50 | 21.90 |
November | 467.67 | 21.07 | 95.33 | 20.94 | 86.17 | 20.77 |
December | 495.83 | 20.50 | 292.50 | 20.29 | 292.50 | 20.20 |
Annual Sum or Average | 4297.50 | 21.46 | 1990.67 | 21.71 | 976.00 | 21.48 |
Minimum of Months | 138.83 | 20.50 | 70.83 | 20.29 | 0.00 | 20.20 |
Maximum of Months | 514.00 | 22.95 | 292.50 | 23.87 | 292.50 | 23.93 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.73 | 279.33 | 20.61 | 279.33 | 20.55 |
February | 453.17 | 21.01 | 163.50 | 20.85 | 163.50 | 20.76 |
March | 513.00 | 21.03 | 150.83 | 20.91 | 150.83 | 20.84 |
April | 389.67 | 22.40 | 38.50 | 22.52 | 9.33 | 22.49 |
May | 331.33 | 22.71 | 86.50 | 23.09 | 0.17 | 23.09 |
June | 161.17 | 23.23 | 217.17 | 23.86 | 2.50 | 23.88 |
July | 108.17 | 23.38 | 306.83 | 24.10 | 8.17 | 24.15 |
August | 127.00 | 23.32 | 251.50 | 23.94 | 4.83 | 23.98 |
September | 254.00 | 22.94 | 134.17 | 23.42 | 0.33 | 23.42 |
October | 466.00 | 21.86 | 19.00 | 21.89 | 8.83 | 21.85 |
November | 489.00 | 21.10 | 97.50 | 20.99 | 97.50 | 20.91 |
December | 497.00 | 20.59 | 331.50 | 20.51 | 331.50 | 20.47 |
Annual Sum or Average | 4291.50 | 21.62 | 2076.33 | 21.86 | 1056.83 | 21.67 |
Minimum of Months | 108.17 | 20.59 | 19.00 | 20.51 | 0.17 | 20.47 |
Maximum of Months | 513.00 | 23.38 | 331.50 | 24.10 | 331.50 | 24.15 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.70 | 270.00 | 20.55 | 270.00 | 20.48 |
February | 454.00 | 20.89 | 176.00 | 20.72 | 176.00 | 20.63 |
March | 514.00 | 21.29 | 101.67 | 21.14 | 101.67 | 21.04 |
April | 416.33 | 22.71 | 7.50 | 22.69 | 5.83 | 22.66 |
May | 359.33 | 23.03 | 27.83 | 23.10 | 0.00 | 23.10 |
June | 143.50 | 23.38 | 147.50 | 23.78 | 0.00 | 23.78 |
July | 107.50 | 23.39 | 218.83 | 23.93 | 0.00 | 23.93 |
August | 140.00 | 23.32 | 167.67 | 23.71 | 0.00 | 23.71 |
September | 295.83 | 22.99 | 54.67 | 23.15 | 0.00 | 23.15 |
October | 495.33 | 21.97 | 18.17 | 21.91 | 18.17 | 21.86 |
November | 489.00 | 21.07 | 117.00 | 20.92 | 117.00 | 20.82 |
December | 497.00 | 20.54 | 296.50 | 20.40 | 296.50 | 20.34 |
Annual Sum or Average | 4413.83 | 21.72 | 1603.33 | 21.73 | 985.17 | 21.53 |
Minimum of Months | 107.50 | 20.54 | 7.50 | 20.40 | 0.00 | 20.34 |
Maximum of Months | 514.00 | 23.39 | 296.50 | 23.93 | 296.50 | 23.93 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 427.00 | 20.69 | 226.67 | 20.55 | 226.67 | 20.48 |
February | 385.00 | 20.96 | 133.17 | 20.81 | 133.17 | 20.72 |
March | 433.00 | 21.17 | 93.67 | 21.03 | 93.67 | 20.93 |
April | 270.17 | 22.62 | 52.17 | 22.89 | 8.17 | 22.90 |
May | 239.50 | 22.79 | 102.33 | 23.33 | 2.67 | 23.36 |
June | 146.17 | 23.31 | 187.67 | 23.95 | 8.50 | 24.02 |
July | 103.17 | 23.64 | 237.83 | 24.31 | 12.67 | 24.41 |
August | 131.67 | 23.43 | 217.50 | 24.01 | 10.83 | 24.10 |
September | 199.67 | 22.91 | 139.17 | 23.59 | 6.33 | 23.65 |
October | 386.67 | 21.73 | 26.67 | 21.73 | 17.17 | 21.67 |
November | 417.00 | 21.00 | 100.67 | 20.87 | 100.67 | 20.78 |
December | 422.00 | 20.49 | 274.00 | 20.37 | 274.00 | 20.32 |
Annual Sum or Average | 3561.00 | 21.61 | 1791.50 | 21.91 | 894.50 | 21.72 |
Minimum of Months | 103.17 | 20.49 | 26.67 | 20.37 | 2.67 | 20.32 |
Maximum of Months | 433.00 | 23.64 | 274.00 | 24.31 | 274.00 | 24.41 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 458.50 | 21.16 | 175.67 | 21.01 | 167.67 | 20.88 |
February | 392.83 | 21.36 | 112.83 | 21.35 | 88.67 | 21.20 |
March | 496.83 | 21.50 | 82.00 | 21.35 | 82.00 | 21.23 |
April | 279.17 | 22.62 | 99.50 | 23.08 | 9.83 | 23.10 |
May | 287.83 | 22.72 | 118.83 | 23.23 | 0.00 | 23.23 |
June | 178.67 | 23.12 | 223.00 | 23.77 | 1.67 | 23.78 |
July | 136.33 | 23.37 | 270.17 | 24.07 | 11.17 | 24.14 |
August | 138.83 | 23.57 | 283.17 | 24.07 | 17.67 | 24.18 |
September | 200.17 | 23.20 | 232.83 | 23.87 | 16.67 | 23.99 |
October | 386.33 | 22.04 | 84.83 | 22.35 | 14.50 | 22.33 |
November | 443.17 | 21.38 | 89.00 | 21.38 | 70.67 | 21.27 |
December | 479.50 | 20.93 | 233.67 | 20.73 | 233.17 | 20.63 |
Annual Sum or Average | 3878.17 | 21.89 | 2005.50 | 22.30 | 713.67 | 22.14 |
Minimum of Months | 136.33 | 20.93 | 82.00 | 20.73 | 0.00 | 20.63 |
Maximum of Months | 496.83 | 23.57 | 283.17 | 24.07 | 233.17 | 24.18 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 501.33 | 20.77 | 245.33 | 20.61 | 245.33 | 20.53 |
February | 440.67 | 21.03 | 140.83 | 20.85 | 140.83 | 20.74 |
March | 507.00 | 21.18 | 108.17 | 21.05 | 108.17 | 20.96 |
April | 368.00 | 22.50 | 66.00 | 22.72 | 11.50 | 22.71 |
May | 327.67 | 22.72 | 108.33 | 23.14 | 4.67 | 23.18 |
June | 175.00 | 23.15 | 226.17 | 23.80 | 6.83 | 23.85 |
July | 143.83 | 23.30 | 288.17 | 24.01 | 12.83 | 24.09 |
August | 166.33 | 23.28 | 245.67 | 23.87 | 12.17 | 23.95 |
September | 275.83 | 22.75 | 134.17 | 23.28 | 4.50 | 23.32 |
October | 459.33 | 21.72 | 38.17 | 21.76 | 18.67 | 21.70 |
November | 486.67 | 21.03 | 113.67 | 20.90 | 113.67 | 20.80 |
December | 497.00 | 20.54 | 308.17 | 20.42 | 308.17 | 20.37 |
Annual Sum or Average | 4348.67 | 21.64 | 2022.83 | 21.90 | 987.33 | 21.72 |
Minimum of Months | 143.83 | 20.54 | 38.17 | 20.42 | 4.50 | 20.37 |
Maximum of Months | 507.00 | 23.30 | 308.17 | 24.01 | 308.17 | 24.09 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 23.44939 | 33.19248 | 0.09313 | 5.83257 |
February | 454.00000 | 23.81801 | 31.68276 | 0.18564 | 5.87170 |
March | 514.00000 | 23.86624 | 30.96974 | 0.19990 | 5.99161 |
April | 485.00000 | 24.32839 | 29.20886 | 0.35037 | 7.78308 |
May | 508.00000 | 24.39943 | 34.61066 | -0.4475 | 9.67129 |
June | 496.00000 | 24.40518 | 41.65372 | -0.3640 | 8.26674 |
July | 497.00000 | 24.46912 | 43.12379 | -0.3292 | 7.78908 |
August | 514.00000 | 24.36638 | 43.10588 | -0.3530 | 8.00825 |
September | 485.00000 | 24.39037 | 40.96326 | -0.3806 | 8.48895 |
October | 502.00000 | 24.26627 | 36.33531 | 0.36554 | 7.99424 |
November | 489.00000 | 23.98105 | 34.66477 | 0.25335 | 6.55516 |
December | 497.00000 | 23.52675 | 30.86338 | 0.09674 | 5.46500 |
Annual Sum or Average | 5943.00000 | 24.10691 | 35.90113 | -0.0300 | 7.31966 |
Minimum of Months | 454.00000 | 23.44939 | 29.20886 | -0.4475 | 5.46500 |
Maximum of Months | 514.00000 | 24.46912 | 43.12379 | 0.36554 | 9.67129 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 21.80447 | 36.25658 | -0.2771 | 7.43813 |
February | 454.00000 | 22.13446 | 35.14328 | -0.1926 | 6.30370 |
March | 514.00000 | 22.36283 | 34.49670 | -0.1372 | 5.89669 |
April | 485.00000 | 23.64608 | 31.43730 | 0.18505 | 6.16223 |
May | 508.00000 | 23.82534 | 36.63449 | -0.6526 | 14.55765 |
June | 496.00000 | 24.05049 | 43.20856 | -0.5033 | 10.62496 |
July | 497.00000 | 24.10202 | 44.51107 | -0.4719 | 10.02731 |
August | 514.00000 | 24.07820 | 44.41844 | -0.4763 | 9.98350 |
September | 485.00000 | 23.90899 | 42.70074 | -0.5653 | 12.11496 |
October | 502.00000 | 23.14083 | 39.93910 | 0.10052 | 5.82307 |
November | 489.00000 | 22.35547 | 38.69693 | -0.1159 | 5.90949 |
December | 497.00000 | 21.64649 | 34.30649 | -0.3262 | 7.83564 |
Annual Sum or Average | 5943.00000 | 23.09400 | 38.50942 | -0.2878 | 8.57795 |
Minimum of Months | 454.00000 | 21.64649 | 31.43730 | -0.6526 | 5.82307 |
Maximum of Months | 514.00000 | 24.10202 | 44.51107 | 0.18505 | 14.55765 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 21.04192 | 36.14225 | -0.4858 | 11.29069 |
February | 454.00000 | 21.28006 | 36.73891 | -0.4109 | 9.54040 |
March | 514.00000 | 21.58896 | 35.87261 | -0.3320 | 8.09570 |
April | 485.00000 | 23.10226 | 32.44546 | 0.05430 | 6.09624 |
May | 508.00000 | 23.39430 | 37.64537 | -0.8013 | 19.88897 |
June | 496.00000 | 23.82222 | 43.87606 | -0.5827 | 12.80787 |
July | 497.00000 | 23.89369 | 45.11205 | -0.5424 | 11.88275 |
August | 514.00000 | 23.85998 | 44.98238 | -0.5556 | 11.96068 |
September | 485.00000 | 23.50037 | 44.05476 | -0.7108 | 16.66635 |
October | 502.00000 | 22.25790 | 41.98625 | -0.1150 | 6.33219 |
November | 489.00000 | 21.43399 | 40.62232 | -0.3486 | 8.45945 |
December | 497.00000 | 20.88364 | 35.70509 | -0.5343 | 12.07025 |
Annual Sum or Average | 5943.00000 | 22.51327 | 39.62289 | -0.4483 | 11.27789 |
Minimum of Months | 454.00000 | 20.88364 | 32.44546 | -0.8013 | 6.09624 |
Maximum of Months | 514.00000 | 23.89369 | 45.11205 | 0.05430 | 19.88897 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.32456 | 38.62862 | -0.6998 | 17.08613 |
February | 454.00000 | 20.45983 | 39.10745 | -0.6422 | 15.10662 |
March | 514.00000 | 20.87785 | 38.33618 | -0.5239 | 11.74738 |
April | 485.00000 | 22.40458 | 34.62852 | -0.1126 | 7.32050 |
May | 508.00000 | 22.83657 | 39.50577 | -0.9859 | 27.91242 |
June | 496.00000 | 23.60698 | 44.87968 | -0.6487 | 15.40901 |
July | 497.00000 | 23.73381 | 45.83106 | -0.5878 | 13.69868 |
August | 514.00000 | 23.57699 | 46.28480 | -0.6513 | 15.32536 |
September | 485.00000 | 22.91618 | 46.01321 | -0.9155 | 25.01717 |
October | 502.00000 | 21.35326 | 45.31740 | -0.3385 | 8.80197 |
November | 489.00000 | 20.58102 | 43.12325 | -0.5828 | 13.38137 |
December | 497.00000 | 20.16077 | 37.57665 | -0.7563 | 18.90284 |
Annual Sum or Average | 5943.00000 | 21.91337 | 41.62414 | -0.6211 | 15.82067 |
Minimum of Months | 454.00000 | 20.16077 | 34.62852 | -0.9859 | 7.32050 |
Maximum of Months | 514.00000 | 23.73381 | 46.28480 | -0.1126 | 27.91242 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.41890 | 37.87298 | -0.6673 | 15.91173 |
February | 454.00000 | 20.64227 | 38.20570 | -0.5860 | 13.50922 |
March | 514.00000 | 20.91480 | 37.63241 | -0.5026 | 11.28875 |
April | 485.00000 | 22.93255 | 32.68519 | 0.06387 | 7.84663 |
May | 508.00000 | 23.19833 | 37.94646 | -0.7915 | 22.02991 |
June | 496.00000 | 23.70411 | 44.05363 | -0.5354 | 13.85451 |
July | 497.00000 | 23.97459 | 44.79329 | -0.4244 | 11.58782 |
August | 514.00000 | 23.77901 | 45.02285 | -0.4895 | 12.64996 |
September | 485.00000 | 23.35239 | 43.95287 | -0.6895 | 18.90009 |
October | 502.00000 | 21.58571 | 44.22149 | -0.2641 | 8.58383 |
November | 489.00000 | 20.65071 | 42.46352 | -0.5579 | 12.63729 |
December | 497.00000 | 20.22280 | 36.95260 | -0.7367 | 18.11966 |
Annual Sum or Average | 5943.00000 | 22.12435 | 40.50662 | -0.5156 | 13.91787 |
Minimum of Months | 454.00000 | 20.22280 | 32.68519 | -0.7915 | 7.84663 |
Maximum of Months | 514.00000 | 23.97459 | 45.02285 | 0.06387 | 22.02991 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 21.00743 | 36.05817 | -0.5060 | 13.57830 |
February | 454.00000 | 21.30919 | 36.21959 | -0.4062 | 11.92410 |
March | 514.00000 | 21.16572 | 36.59473 | -0.4389 | 10.76643 |
April | 485.00000 | 22.88847 | 32.20659 | 0.05937 | 8.60432 |
May | 508.00000 | 22.95832 | 38.11263 | -0.8826 | 26.11543 |
June | 496.00000 | 23.48677 | 44.39895 | -0.6307 | 16.60785 |
July | 497.00000 | 23.73368 | 45.20488 | -0.5189 | 14.20355 |
August | 514.00000 | 23.69026 | 44.96488 | -0.5105 | 14.07282 |
September | 485.00000 | 23.41102 | 43.28871 | -0.6281 | 18.99251 |
October | 502.00000 | 21.98812 | 42.44250 | -0.1469 | 8.85474 |
November | 489.00000 | 21.17757 | 40.76388 | -0.4173 | 11.36528 |
December | 497.00000 | 20.61273 | 35.61176 | -0.6286 | 15.81955 |
Annual Sum or Average | 5943.00000 | 22.29137 | 39.68877 | -0.4731 | 14.27057 |
Minimum of Months | 454.00000 | 20.61273 | 32.20659 | -0.8826 | 8.60432 |
Maximum of Months | 514.00000 | 23.73368 | 45.20488 | 0.05937 | 26.11543 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.42929 | 37.57759 | -0.6689 | 16.26729 |
February | 454.00000 | 20.73146 | 37.74058 | -0.5651 | 13.94580 |
March | 514.00000 | 20.88042 | 37.40594 | -0.5129 | 11.75408 |
April | 485.00000 | 22.44361 | 33.54553 | -0.0551 | 8.22474 |
May | 508.00000 | 22.78106 | 38.81702 | -0.9265 | 28.06400 |
June | 496.00000 | 23.46125 | 44.76337 | -0.6065 | 16.56796 |
July | 497.00000 | 23.64915 | 45.78730 | -0.5219 | 14.65304 |
August | 514.00000 | 23.49157 | 46.03996 | -0.5917 | 15.87045 |
September | 485.00000 | 22.87257 | 45.31708 | -0.8543 | 24.95158 |
October | 502.00000 | 21.39795 | 44.35847 | -0.3088 | 8.95247 |
November | 489.00000 | 20.64918 | 42.18161 | -0.5619 | 13.04310 |
December | 497.00000 | 20.19263 | 36.75886 | -0.7511 | 18.67407 |
Annual Sum or Average | 5943.00000 | 21.92349 | 40.88501 | -0.5780 | 15.93423 |
Minimum of Months | 454.00000 | 20.19263 | 33.54553 | -0.9265 | 8.22474 |
Maximum of Months | 514.00000 | 23.64915 | 46.03996 | -0.0551 | 28.06400 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.63106 | 38.15546 | -0.6077 | 13.66501 |
February | 454.00000 | 20.74002 | 38.71920 | -0.5577 | 11.98990 |
March | 514.00000 | 21.01514 | 37.86443 | -0.4808 | 10.25589 |
April | 485.00000 | 22.29935 | 34.89318 | -0.1433 | 6.42882 |
May | 508.00000 | 22.89498 | 39.68749 | -0.9856 | 26.83883 |
June | 496.00000 | 23.66410 | 45.23201 | -0.6553 | 14.75151 |
July | 497.00000 | 23.82670 | 46.03902 | -0.5795 | 12.60446 |
August | 514.00000 | 23.66144 | 46.59806 | -0.6412 | 14.20456 |
September | 485.00000 | 23.21180 | 45.65310 | -0.8250 | 20.39350 |
October | 502.00000 | 21.88397 | 43.71989 | -0.1975 | 6.55035 |
November | 489.00000 | 21.07442 | 41.99212 | -0.4322 | 9.42573 |
December | 497.00000 | 20.58856 | 36.97439 | -0.6193 | 13.57876 |
Annual Sum or Average | 5943.00000 | 22.13411 | 41.31697 | -0.5614 | 13.41850 |
Minimum of Months | 454.00000 | 20.58856 | 34.89318 | -0.9856 | 6.42882 |
Maximum of Months | 514.00000 | 23.82670 | 46.59806 | -0.1433 | 26.83883 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.75831 | 38.02871 | -0.5649 | 12.47779 |
February | 454.00000 | 20.97287 | 38.33212 | -0.4878 | 10.56471 |
March | 514.00000 | 21.10743 | 37.69432 | -0.4476 | 9.72447 |
April | 485.00000 | 23.24312 | 32.46087 | 0.12105 | 6.94885 |
May | 508.00000 | 23.59037 | 37.46315 | -0.6894 | 17.33831 |
June | 496.00000 | 23.95187 | 43.75094 | -0.4840 | 11.39393 |
July | 497.00000 | 24.21278 | 44.44522 | -0.3714 | 9.36768 |
August | 514.00000 | 24.06488 | 44.61351 | -0.4148 | 9.78362 |
September | 485.00000 | 23.86899 | 42.90626 | -0.5280 | 12.59562 |
October | 502.00000 | 22.25871 | 42.76956 | -0.0910 | 6.62212 |
November | 489.00000 | 21.16731 | 41.90250 | -0.3994 | 8.88846 |
December | 497.00000 | 20.64446 | 36.93442 | -0.5995 | 13.07973 |
Annual Sum or Average | 5943.00000 | 22.49589 | 40.12966 | -0.4138 | 10.74421 |
Minimum of Months | 454.00000 | 20.64446 | 32.46087 | -0.6894 | 6.62212 |
Maximum of Months | 514.00000 | 24.21278 | 44.61351 | 0.12105 | 17.33831 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.80526 | 35.09119 | -0.5022 | 12.67661 |
February | 454.00000 | 21.10570 | 35.50929 | -0.4029 | 10.52111 |
March | 514.00000 | 20.74360 | 35.59435 | -0.5027 | 11.26014 |
April | 485.00000 | 22.65844 | 31.94217 | 0.01399 | 7.62519 |
May | 508.00000 | 22.71865 | 38.17146 | -0.9510 | 27.66877 |
June | 496.00000 | 23.25649 | 44.95998 | -0.7115 | 18.18606 |
July | 497.00000 | 23.72860 | 45.50037 | -0.5325 | 13.12616 |
August | 514.00000 | 23.82362 | 45.01947 | -0.4715 | 11.84977 |
September | 485.00000 | 23.76815 | 42.32909 | -0.4989 | 13.42742 |
October | 502.00000 | 22.29865 | 40.67494 | -0.0375 | 7.64106 |
November | 489.00000 | 21.24452 | 39.31813 | -0.3429 | 9.29356 |
December | 497.00000 | 20.51046 | 34.54497 | -0.5930 | 13.81533 |
Annual Sum or Average | 5943.00000 | 22.22721 | 39.09023 | -0.4632 | 13.13740 |
Minimum of Months | 454.00000 | 20.51046 | 31.94217 | -0.9510 | 7.62519 |
Maximum of Months | 514.00000 | 23.82362 | 45.50037 | 0.01399 | 27.66877 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.73347 | 37.67045 | -0.5739 | 12.84315 |
February | 454.00000 | 21.01672 | 37.82896 | -0.4747 | 10.65237 |
March | 514.00000 | 21.03637 | 37.40298 | -0.4646 | 10.08792 |
April | 485.00000 | 22.75627 | 33.31217 | 0.00074 | 6.83588 |
May | 508.00000 | 23.25597 | 38.12141 | -0.7998 | 21.51034 |
June | 496.00000 | 23.86602 | 44.03059 | -0.5065 | 12.01429 |
July | 497.00000 | 24.02021 | 45.02176 | -0.4277 | 10.49343 |
August | 514.00000 | 23.91728 | 45.27098 | -0.4771 | 11.03310 |
September | 485.00000 | 23.52144 | 44.04706 | -0.6580 | 16.08336 |
October | 502.00000 | 22.02459 | 42.98531 | -0.1440 | 6.72778 |
November | 489.00000 | 21.10039 | 41.62854 | -0.4162 | 9.25947 |
December | 497.00000 | 20.59433 | 36.65012 | -0.6196 | 13.60503 |
Annual Sum or Average | 5943.00000 | 22.32881 | 40.35492 | -0.4645 | 11.78260 |
Minimum of Months | 454.00000 | 20.59433 | 33.31217 | -0.7998 | 6.72778 |
Maximum of Months | 514.00000 | 24.02021 | 45.27098 | 0.00074 | 21.51034 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.70291 | 37.90362 | -0.5726 | 13.03943 |
February | 454.00000 | 20.88766 | 38.34307 | -0.5032 | 11.01614 |
March | 514.00000 | 21.28585 | 37.60486 | -0.3961 | 9.00583 |
April | 485.00000 | 22.89814 | 33.74454 | 0.01073 | 6.23984 |
May | 508.00000 | 23.31732 | 38.45137 | -0.8225 | 20.69475 |
June | 496.00000 | 23.86638 | 44.10694 | -0.5597 | 12.23780 |
July | 497.00000 | 23.95868 | 45.16123 | -0.5114 | 11.07701 |
August | 514.00000 | 23.82881 | 45.57217 | -0.5624 | 12.16632 |
September | 485.00000 | 23.38340 | 44.66967 | -0.7538 | 18.19727 |
October | 502.00000 | 22.00078 | 43.77757 | -0.1659 | 6.65998 |
November | 489.00000 | 21.06543 | 42.10926 | -0.4312 | 9.65494 |
December | 497.00000 | 20.53694 | 36.86355 | -0.6247 | 14.04832 |
Annual Sum or Average | 5943.00000 | 22.32104 | 40.71406 | -0.4919 | 12.01689 |
Minimum of Months | 454.00000 | 20.53694 | 33.74454 | -0.8225 | 6.23984 |
Maximum of Months | 514.00000 | 23.95868 | 45.57217 | 0.01073 | 20.69475 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 427.00000 | 20.69039 | 36.64579 | -0.5730 | 12.86859 |
February | 385.00000 | 20.96165 | 36.73432 | -0.4821 | 10.60743 |
March | 433.00000 | 21.16713 | 36.50509 | -0.4179 | 9.35539 |
April | 410.00000 | 23.15234 | 31.96649 | 0.11603 | 7.30945 |
May | 430.00000 | 23.45469 | 36.89454 | -0.7108 | 18.77166 |
June | 418.00000 | 23.87080 | 43.24613 | -0.4915 | 12.29788 |
July | 422.00000 | 24.14035 | 44.08170 | -0.3855 | 10.44779 |
August | 433.00000 | 23.92548 | 44.46333 | -0.4545 | 11.38147 |
September | 410.00000 | 23.60015 | 42.97954 | -0.6107 | 15.86563 |
October | 427.00000 | 21.96077 | 42.51508 | -0.1592 | 7.10816 |
November | 417.00000 | 20.99637 | 40.96253 | -0.4445 | 9.79001 |
December | 422.00000 | 20.49224 | 35.73988 | -0.6360 | 14.27827 |
Annual Sum or Average | 5034.00000 | 22.37383 | 39.41979 | -0.4383 | 11.68533 |
Minimum of Months | 385.00000 | 20.49224 | 31.96649 | -0.7108 | 7.10816 |
Maximum of Months | 433.00000 | 24.14035 | 44.46333 | 0.11603 | 18.77166 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 21.43169 | 35.31147 | -0.3717 | 10.54504 |
February | 454.00000 | 21.76326 | 35.40964 | -0.2651 | 9.30071 |
March | 514.00000 | 21.58532 | 35.87884 | -0.3104 | 8.46672 |
April | 485.00000 | 23.28888 | 31.46292 | 0.16235 | 7.90223 |
May | 508.00000 | 23.38866 | 37.18515 | -0.7347 | 19.60694 |
June | 496.00000 | 23.78247 | 43.63432 | -0.5336 | 12.86825 |
July | 497.00000 | 23.98058 | 44.52247 | -0.4388 | 11.16409 |
August | 514.00000 | 23.95366 | 44.32791 | -0.4219 | 10.93427 |
September | 485.00000 | 23.77716 | 42.27018 | -0.4973 | 13.86037 |
October | 502.00000 | 22.52602 | 41.13723 | 0.00216 | 7.58572 |
November | 489.00000 | 21.67702 | 39.77252 | -0.2649 | 8.75482 |
December | 497.00000 | 21.04467 | 34.84715 | -0.4872 | 11.89076 |
Annual Sum or Average | 5943.00000 | 22.68829 | 38.84708 | -0.3487 | 11.09431 |
Minimum of Months | 454.00000 | 21.04467 | 31.46292 | -0.7347 | 7.58572 |
Maximum of Months | 514.00000 | 23.98058 | 44.52247 | 0.16235 | 19.60694 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.77595 | 36.98983 | -0.5479 | 12.53026 |
February | 454.00000 | 21.11661 | 37.07491 | -0.4354 | 10.46003 |
March | 514.00000 | 21.22262 | 36.82614 | -0.3978 | 9.23054 |
April | 485.00000 | 22.89148 | 32.79044 | 0.05840 | 7.22035 |
May | 508.00000 | 23.23864 | 37.86107 | -0.7705 | 21.06932 |
June | 496.00000 | 23.77731 | 43.97088 | -0.5034 | 12.67324 |
July | 497.00000 | 23.91976 | 45.05088 | -0.4348 | 11.42517 |
August | 514.00000 | 23.80003 | 45.31748 | -0.4891 | 12.12254 |
September | 485.00000 | 23.34365 | 44.08718 | -0.6932 | 18.16904 |
October | 502.00000 | 21.91931 | 43.14411 | -0.1604 | 7.08215 |
November | 489.00000 | 21.04600 | 41.41598 | -0.4269 | 9.71327 |
December | 497.00000 | 20.54351 | 36.13551 | -0.6246 | 14.02574 |
Annual Sum or Average | 5943.00000 | 22.30762 | 40.08274 | -0.4532 | 12.16080 |
Minimum of Months | 454.00000 | 20.54351 | 32.79044 | -0.7705 | 7.08215 |
Maximum of Months | 514.00000 | 23.91976 | 45.31748 | 0.05840 | 21.06932 |
Report: BoilerReportMonthly
For: HEATSYS1 BOILER
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportBOILER HEATING ENERGY [J] | BOILER GAS CONSUMPTION [] | BOILER HEATING ENERGY {HOURS NON-ZERO} [HOURS] | BOILER HEATING RATE {Maximum} [W] | BOILER HEATING RATE {TIMESTAMP} | BOILER GAS CONSUMPTION RATE [] | BOILER INLET TEMPERATURE [C] | BOILER OUTLET TEMPERATURE [C] | BOILER MASS FLOW RATE [kg/s] | BOILER ANCILLARY ELECTRICITY RATE [W] | BOILER PART LOAD RATIO [] | BOILER PART LOAD RATIO {Maximum} [] | BOILER PART LOAD RATIO {TIMESTAMP} | |
January | 0.443795E+11 | 0.00 | 380.70 | 160998.41 | 30-JAN-06:11 | 0.00 | 30.65 | 45.47 | 0.15 | 0.00 | 0.07 | 0.67 | 30-JAN-06:11 |
February | 0.283494E+11 | 0.00 | 338.40 | 157538.42 | 23-FEB-07:01 | 0.00 | 29.31 | 44.75 | 0.10 | 0.00 | 0.05 | 0.65 | 23-FEB-07:01 |
March | 0.238322E+11 | 0.00 | 375.65 | 163949.87 | 21-MAR-06:01 | 0.00 | 27.82 | 43.54 | 0.07 | 0.00 | 0.04 | 0.68 | 21-MAR-06:01 |
April | 0.334763E+10 | 0.00 | 126.03 | 147580.33 | 03-APR-06:02 | 0.00 | 31.69 | 36.68 | 0.01 | 0.00 | 0.01 | 0.61 | 03-APR-06:02 |
May | 0.161768E+10 | 0.00 | 91.00 | 69065.12 | 05-MAY-06:03 | 0.00 | 35.42 | 38.42 | 0.01 | 0.00 | 0.00 | 0.29 | 05-MAY-06:03 |
June | 0.448187E+09 | 0.00 | 57.30 | 12977.82 | 08-JUN-06:03 | 0.00 | 40.28 | 41.84 | 0.00 | 0.00 | 0.00 | 0.05 | 08-JUN-06:03 |
July | 0.168637E+09 | 0.00 | 47.80 | 9589.99 | 20-JUL-06:05 | 0.00 | 38.33 | 39.67 | 0.00 | 0.00 | 0.00 | 0.04 | 20-JUL-06:05 |
August | 0.154072E+09 | 0.00 | 47.22 | 11407.79 | 21-AUG-06:07 | 0.00 | 33.88 | 35.62 | 0.00 | 0.00 | 0.00 | 0.05 | 21-AUG-06:07 |
September | 0.525049E+09 | 0.00 | 46.32 | 55160.34 | 21-SEP-06:03 | 0.00 | 36.45 | 38.03 | 0.00 | 0.00 | 0.00 | 0.23 | 21-SEP-06:03 |
October | 0.665267E+10 | 0.00 | 238.96 | 140904.75 | 19-OCT-06:03 | 0.00 | 27.61 | 37.57 | 0.02 | 0.00 | 0.01 | 0.58 | 19-OCT-06:03 |
November | 0.220048E+11 | 0.00 | 343.76 | 159775.76 | 27-NOV-06:11 | 0.00 | 27.13 | 42.27 | 0.07 | 0.00 | 0.04 | 0.66 | 27-NOV-06:11 |
December | 0.467097E+11 | 0.00 | 382.11 | 153246.86 | 13-DEC-07:01 | 0.00 | 30.05 | 45.40 | 0.15 | 0.00 | 0.07 | 0.63 | 13-DEC-07:01 |
Annual Sum or Average | 0.178189E+12 | 0.00 | 2475.26 | 0.00 | 32.39 | 40.75 | 0.05 | 0.00 | 0.02 | ||||
Minimum of Months | 0.154072E+09 | 0.00 | 46.32 | 9589.99 | 0.00 | 27.13 | 35.62 | 0.00 | 0.00 | 0.00 | 0.04 | ||
Maximum of Months | 0.467097E+11 | 0.00 | 382.11 | 163949.87 | 0.00 | 40.28 | 45.47 | 0.15 | 0.00 | 0.07 | 0.68 |
Report: DXReportMonthly
For: PACU_VAV_BOT COOLING COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 |
April | 0.165716E+10 | 0.396729E+09 | 49.78 | 0.158759E+10 | 69566319.24 | 0.00 | 1.00 | 30-APR-13:31 | 0.00 | 01-APR-00:10 | 33968.14 | 30-APR-15:31 | 33968.14 | 30-APR-15:31 | 5018.83 | 28-APR-08:00 | 7166.77 | 30-APR-15:31 | 0.00 |
May | 0.266743E+10 | 0.609433E+09 | 61.03 | 0.227714E+10 | 0.390294E+09 | 0.00 | 1.00 | 22-MAY-12:40 | 0.00 | 01-MAY-00:10 | 43730.43 | 22-MAY-15:00 | 43730.43 | 22-MAY-15:00 | 5575.92 | 23-MAY-15:20 | 9221.24 | 22-MAY-15:00 | 0.00 |
June | 0.910238E+10 | 0.203391E+10 | 152.99 | 0.754193E+10 | 0.156045E+10 | 0.00 | 1.00 | 12-JUN-12:10 | 0.00 | 01-JUN-00:10 | 62011.75 | 13-JUN-16:00 | 56670.86 | 13-JUN-16:00 | 21334.42 | 25-JUN-17:41 | 13887.84 | 13-JUN-16:00 | 0.00 |
July | 0.154463E+11 | 0.351545E+10 | 274.39 | 0.125732E+11 | 0.287307E+10 | 0.00 | 1.00 | 06-JUL-14:00 | 0.00 | 01-JUL-00:10 | 57482.29 | 21-JUL-16:00 | 57482.29 | 21-JUL-16:00 | 13080.91 | 24-JUL-15:30 | 13382.63 | 21-JUL-16:00 | 0.00 |
August | 0.198093E+11 | 0.449336E+10 | 358.37 | 0.156851E+11 | 0.412422E+10 | 0.00 | 1.00 | 07-AUG-14:50 | 0.00 | 01-AUG-00:10 | 56935.84 | 14-AUG-15:50 | 55917.14 | 14-AUG-16:00 | 12193.73 | 18-AUG-15:40 | 12575.79 | 14-AUG-16:00 | 0.00 |
September | 0.996732E+10 | 0.225251E+10 | 197.41 | 0.821777E+10 | 0.174954E+10 | 0.00 | 1.00 | 11-SEP-12:20 | 0.00 | 01-SEP-00:10 | 48888.34 | 13-SEP-15:20 | 44254.99 | 13-SEP-15:20 | 11873.55 | 12-SEP-14:00 | 10253.75 | 13-SEP-15:20 | 0.00 |
October | 0.367213E+09 | 93995753.69 | 22.17 | 0.352012E+09 | 15200866.84 | 0.00 | 0.48 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 | 11237.88 | 07-OCT-15:00 | 11237.88 | 07-OCT-15:00 | 1659.96 | 17-OCT-15:00 | 2727.13 | 07-OCT-15:00 | 0.00 |
November | 3627594.25 | 967521.89 | 0.67 | 2532434.30 | 1095159.95 | 0.00 | 0.13 | 24-NOV-12:00 | 0.00 | 01-NOV-00:10 | 2726.22 | 24-NOV-12:00 | 1950.72 | 24-NOV-12:00 | 775.49 | 24-NOV-12:00 | 721.14 | 24-NOV-12:00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 |
Annual Sum or Average | 0.590207E+11 | 0.133963E+11 | 1116.81 | 0.482373E+11 | 0.107834E+11 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Maximum of Months | 0.198093E+11 | 0.449336E+10 | 358.37 | 0.156851E+11 | 0.412422E+10 | 0.00 | 1.00 | 0.00 | 62011.75 | 57482.29 | 21334.42 | 13887.84 | 0.00 |
Report: DXReportMonthly
For: PACU_VAV_MID COOLING COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 |
April | 0.169940E+10 | 0.402180E+09 | 50.58 | 0.164012E+10 | 59280722.08 | 0.00 | 1.00 | 28-APR-14:50 | 0.00 | 01-APR-00:10 | 36018.95 | 30-APR-16:02 | 36018.95 | 30-APR-16:02 | 3631.01 | 28-APR-08:00 | 7597.45 | 30-APR-16:02 | 0.00 |
May | 0.258085E+10 | 0.587576E+09 | 62.28 | 0.221394E+10 | 0.366912E+09 | 0.00 | 1.00 | 22-MAY-12:30 | 0.00 | 01-MAY-00:10 | 41431.84 | 22-MAY-15:00 | 41431.84 | 22-MAY-15:00 | 5358.65 | 23-MAY-15:20 | 8736.24 | 22-MAY-15:00 | 0.00 |
June | 0.859590E+10 | 0.192017E+10 | 153.48 | 0.713659E+10 | 0.145931E+10 | 0.00 | 1.00 | 12-JUN-11:50 | 0.00 | 01-JUN-00:10 | 58229.78 | 13-JUN-15:30 | 52882.15 | 13-JUN-15:30 | 16420.67 | 25-JUN-17:54 | 13002.30 | 13-JUN-16:00 | 0.00 |
July | 0.142948E+11 | 0.325453E+10 | 275.85 | 0.116285E+11 | 0.266632E+10 | 0.00 | 1.00 | 06-JUL-13:50 | 0.00 | 01-JUL-00:10 | 52739.87 | 21-JUL-15:40 | 52739.87 | 21-JUL-15:40 | 11958.53 | 24-JUL-15:30 | 12255.45 | 21-JUL-16:00 | 0.00 |
August | 0.179853E+11 | 0.408506E+10 | 359.66 | 0.142172E+11 | 0.376801E+10 | 0.00 | 1.00 | 07-AUG-15:00 | 0.00 | 01-AUG-00:10 | 52237.87 | 14-AUG-15:30 | 50608.34 | 14-AUG-15:50 | 11337.30 | 18-AUG-15:30 | 11444.13 | 14-AUG-15:50 | 0.00 |
September | 0.909981E+10 | 0.205909E+10 | 198.32 | 0.748338E+10 | 0.161643E+10 | 0.00 | 1.00 | 10-SEP-16:12 | 0.00 | 01-SEP-00:10 | 44202.81 | 13-SEP-14:50 | 40129.52 | 13-SEP-14:50 | 11589.33 | 12-SEP-14:00 | 9271.87 | 13-SEP-14:50 | 0.00 |
October | 0.316370E+09 | 81260129.22 | 22.17 | 0.303283E+09 | 13086993.11 | 0.00 | 0.47 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 | 10457.21 | 07-OCT-15:00 | 10457.21 | 07-OCT-15:00 | 1188.99 | 17-OCT-15:00 | 2538.92 | 07-OCT-15:00 | 0.00 |
November | 3121318.34 | 834067.44 | 0.67 | 2149836.75 | 971481.60 | 0.00 | 0.12 | 24-NOV-12:00 | 0.00 | 01-NOV-00:10 | 2325.31 | 24-NOV-12:00 | 1634.43 | 24-NOV-12:00 | 690.89 | 24-NOV-12:00 | 616.65 | 24-NOV-12:00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 |
Annual Sum or Average | 0.545755E+11 | 0.123907E+11 | 1123.00 | 0.446252E+11 | 0.995032E+10 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Maximum of Months | 0.179853E+11 | 0.408506E+10 | 359.66 | 0.142172E+11 | 0.376801E+10 | 0.00 | 1.00 | 0.00 | 58229.78 | 52882.15 | 16420.67 | 13002.30 | 0.00 |
Report: DXReportMonthly
For: PACU_VAV_TOP COOLING COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 37783.32 | 10264.25 | 0.04 | 33482.03 | 4301.30 | 0.00 | 0.01 | 09-JAN-05:50 | 0.00 | 01-JAN-00:05 | 251.89 | 09-JAN-05:50 | 223.21 | 09-JAN-05:50 | 28.68 | 09-JAN-05:50 | 68.43 | 09-JAN-05:50 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 |
April | 0.172034E+10 | 0.410350E+09 | 49.81 | 0.165004E+10 | 70306289.38 | 0.00 | 1.00 | 30-APR-12:22 | 0.00 | 01-APR-00:10 | 37281.89 | 30-APR-16:22 | 37281.89 | 30-APR-16:22 | 2726.79 | 28-APR-08:00 | 7865.11 | 30-APR-16:22 | 0.00 |
May | 0.265047E+10 | 0.608163E+09 | 61.33 | 0.225245E+10 | 0.398015E+09 | 0.00 | 1.00 | 22-MAY-12:50 | 0.00 | 01-MAY-00:10 | 44638.13 | 22-MAY-15:00 | 44638.13 | 22-MAY-15:00 | 5759.61 | 23-MAY-14:50 | 9413.14 | 22-MAY-15:00 | 0.00 |
June | 0.889391E+10 | 0.199726E+10 | 150.82 | 0.735563E+10 | 0.153828E+10 | 0.00 | 1.00 | 12-JUN-12:10 | 0.00 | 01-JUN-00:10 | 67275.96 | 13-JUN-14:40 | 61066.17 | 13-JUN-15:40 | 24219.60 | 25-JUN-17:52 | 14821.98 | 13-JUN-15:40 | 0.00 |
July | 0.146668E+11 | 0.336395E+10 | 271.34 | 0.119150E+11 | 0.275184E+10 | 0.00 | 1.00 | 06-JUL-14:20 | 0.00 | 01-JUL-00:10 | 60941.63 | 21-JUL-15:50 | 60941.63 | 21-JUL-15:50 | 12148.29 | 24-JUL-15:30 | 14117.98 | 21-JUL-15:50 | 0.00 |
August | 0.177848E+11 | 0.408632E+10 | 357.96 | 0.139049E+11 | 0.387995E+10 | 0.00 | 1.00 | 13-AUG-13:02 | 0.00 | 01-AUG-00:10 | 56834.38 | 14-AUG-15:40 | 56834.38 | 14-AUG-15:40 | 11558.42 | 18-AUG-15:30 | 12527.62 | 14-AUG-16:00 | 0.00 |
September | 0.865673E+10 | 0.198284E+10 | 191.42 | 0.704163E+10 | 0.161510E+10 | 0.00 | 1.00 | 10-SEP-11:53 | 0.00 | 01-SEP-00:10 | 44509.68 | 13-SEP-15:00 | 40712.19 | 13-SEP-15:00 | 11068.04 | 12-SEP-14:00 | 9338.74 | 13-SEP-15:00 | 0.00 |
October | 0.287355E+09 | 74470520.62 | 21.67 | 0.271109E+09 | 16245593.40 | 0.00 | 0.42 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 | 10236.53 | 07-OCT-15:00 | 10236.53 | 07-OCT-15:00 | 1248.90 | 17-OCT-15:00 | 2518.86 | 07-OCT-15:00 | 0.00 |
November | 3243000.23 | 867632.15 | 0.67 | 2206059.70 | 1036940.54 | 0.00 | 0.11 | 24-NOV-12:00 | 0.00 | 01-NOV-00:10 | 2428.47 | 24-NOV-12:00 | 1684.22 | 24-NOV-12:00 | 744.25 | 24-NOV-12:00 | 645.09 | 24-NOV-12:00 | 0.00 |
December | 110070.61 | 29894.35 | 0.11 | 92625.08 | 17445.53 | 0.00 | 0.01 | 18-DEC-05:20 | 0.00 | 01-DEC-00:10 | 290.37 | 18-DEC-05:20 | 237.98 | 18-DEC-05:20 | 52.40 | 18-DEC-05:20 | 78.85 | 18-DEC-05:20 | 0.00 |
Annual Sum or Average | 0.546638E+11 | 0.125243E+11 | 1105.17 | 0.443930E+11 | 0.102708E+11 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Maximum of Months | 0.177848E+11 | 0.408632E+10 | 357.96 | 0.139049E+11 | 0.387995E+10 | 0.00 | 1.00 | 0.00 | 67275.96 | 61066.17 | 24219.60 | 14821.98 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 258.91 | 0.00 | 258.91 | 24.15 | 1483.94 | 0.00 | 0.00 | 0.00 |
February | 404.29 | 0.00 | 404.29 | 71.17 | 1396.30 | 0.00 | 0.00 | 0.00 |
March | 559.47 | 0.00 | 559.47 | 205.98 | 1150.21 | 0.00 | 0.00 | 0.00 |
April | 910.90 | 4.08 | 906.83 | 583.38 | 975.59 | 0.00 | 0.00 | 0.00 |
May | 1138.86 | 54.94 | 1083.92 | 734.30 | 794.42 | 0.00 | 0.00 | 0.00 |
June | 1258.94 | 78.94 | 1180.00 | 1038.45 | 636.73 | 0.00 | 0.00 | 0.00 |
July | 1194.17 | 68.09 | 1126.09 | 1054.22 | 589.06 | 0.00 | 0.00 | 0.00 |
August | 938.68 | 14.71 | 923.97 | 811.68 | 655.29 | 0.00 | 0.00 | 0.00 |
September | 714.47 | 0.16 | 714.31 | 536.78 | 859.86 | 0.00 | 0.00 | 0.00 |
October | 457.82 | 0.00 | 457.82 | 203.91 | 1084.95 | 0.00 | 0.00 | 0.00 |
November | 275.08 | 0.00 | 275.08 | 36.98 | 1306.77 | 0.00 | 0.00 | 0.00 |
December | 187.33 | 0.00 | 187.33 | 3.06 | 1592.70 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 692.86 | 18.53 | 674.33 | 443.88 | 1042.01 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 187.33 | 0.00 | 187.33 | 3.06 | 589.06 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1258.94 | 78.94 | 1180.00 | 1054.22 | 1592.70 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 352.80 | 141.72 | 211.08 | 214.57 | 930.82 | 0.00 | 0.00 | 0.00 |
February | 526.08 | 194.34 | 331.74 | 353.27 | 885.93 | 0.00 | 0.00 | 0.00 |
March | 549.77 | 108.34 | 441.43 | 350.57 | 729.99 | 0.00 | 0.00 | 0.00 |
April | 1476.18 | 693.66 | 782.51 | 1538.59 | 624.07 | 0.00 | 0.00 | 0.00 |
May | 1552.15 | 676.87 | 875.29 | 1570.73 | 544.39 | 0.00 | 0.00 | 0.00 |
June | 1536.35 | 613.60 | 922.74 | 1652.80 | 433.59 | 0.00 | 0.00 | 0.00 |
July | 1568.31 | 666.53 | 901.78 | 1761.72 | 402.57 | 0.00 | 0.00 | 0.00 |
August | 1485.63 | 709.82 | 775.81 | 1721.08 | 435.11 | 0.00 | 0.00 | 0.00 |
September | 1337.86 | 711.41 | 626.45 | 1502.30 | 547.63 | 0.00 | 0.00 | 0.00 |
October | 645.80 | 267.64 | 378.16 | 579.28 | 699.37 | 0.00 | 0.00 | 0.00 |
November | 336.68 | 114.74 | 221.93 | 202.56 | 832.28 | 0.00 | 0.00 | 0.00 |
December | 249.52 | 92.77 | 156.75 | 132.51 | 1013.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 969.49 | 416.49 | 553.01 | 967.19 | 672.19 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 249.52 | 92.77 | 156.75 | 132.51 | 402.57 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1568.31 | 711.41 | 922.74 | 1761.72 | 1013.12 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1469.89 | 951.52 | 518.37 | 1469.75 | 1350.28 | 0.00 | 0.00 | 0.00 |
February | 1795.21 | 1095.46 | 699.75 | 1836.50 | 1336.38 | 0.00 | 0.00 | 0.00 |
March | 1109.91 | 323.16 | 786.76 | 919.11 | 1117.81 | 0.00 | 0.00 | 0.00 |
April | 2304.83 | 1041.76 | 1263.07 | 2617.78 | 1018.46 | 0.00 | 0.00 | 0.00 |
May | 1906.31 | 620.63 | 1285.68 | 1996.35 | 892.28 | 0.00 | 0.00 | 0.00 |
June | 1756.12 | 425.08 | 1331.03 | 1910.38 | 700.29 | 0.00 | 0.00 | 0.00 |
July | 1902.72 | 595.86 | 1306.86 | 2231.03 | 652.67 | 0.00 | 0.00 | 0.00 |
August | 2229.57 | 1002.94 | 1226.63 | 2773.24 | 706.09 | 0.00 | 0.00 | 0.00 |
September | 2634.77 | 1543.49 | 1091.28 | 3250.85 | 883.03 | 0.00 | 0.00 | 0.00 |
October | 1810.19 | 1057.98 | 752.22 | 2005.51 | 1078.27 | 0.00 | 0.00 | 0.00 |
November | 1283.43 | 780.74 | 502.69 | 1288.21 | 1253.21 | 0.00 | 0.00 | 0.00 |
December | 1017.23 | 651.75 | 365.49 | 988.64 | 1515.54 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1765.65 | 837.60 | 928.05 | 1937.89 | 1040.46 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 1017.23 | 323.16 | 365.49 | 919.11 | 652.67 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2634.77 | 1543.49 | 1331.03 | 3250.85 | 1515.54 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 343.08 | 113.35 | 229.72 | 213.49 | 947.79 | 0.00 | 0.00 | 0.00 |
February | 607.44 | 256.48 | 350.96 | 489.07 | 913.47 | 0.00 | 0.00 | 0.00 |
March | 549.26 | 105.07 | 444.18 | 349.49 | 740.82 | 0.00 | 0.00 | 0.00 |
April | 1295.99 | 514.78 | 781.21 | 1333.64 | 659.63 | 0.00 | 0.00 | 0.00 |
May | 1520.49 | 618.28 | 902.21 | 1548.19 | 574.15 | 0.00 | 0.00 | 0.00 |
June | 1641.97 | 675.94 | 966.03 | 1801.63 | 459.81 | 0.00 | 0.00 | 0.00 |
July | 1672.27 | 737.31 | 934.96 | 1916.91 | 429.47 | 0.00 | 0.00 | 0.00 |
August | 1404.60 | 608.15 | 796.45 | 1628.81 | 465.27 | 0.00 | 0.00 | 0.00 |
September | 1126.86 | 505.31 | 621.55 | 1259.74 | 580.86 | 0.00 | 0.00 | 0.00 |
October | 601.14 | 216.17 | 384.97 | 537.31 | 720.27 | 0.00 | 0.00 | 0.00 |
November | 325.31 | 94.96 | 230.35 | 204.82 | 856.79 | 0.00 | 0.00 | 0.00 |
December | 184.14 | 38.86 | 145.28 | 70.70 | 1050.43 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 940.37 | 373.87 | 566.50 | 947.67 | 698.81 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 184.14 | 38.86 | 145.28 | 70.70 | 429.47 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1672.27 | 737.31 | 966.03 | 1916.91 | 1050.43 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 86.30 | 0.00 | 86.30 | 7.27 | 517.79 | 0.00 | 0.00 | 0.00 |
February | 134.76 | 0.00 | 134.76 | 22.39 | 486.40 | 0.00 | 0.00 | 0.00 |
March | 186.48 | 0.00 | 186.48 | 69.37 | 397.18 | 0.00 | 0.00 | 0.00 |
April | 303.62 | 1.36 | 302.26 | 203.21 | 328.96 | 0.00 | 0.00 | 0.00 |
May | 379.60 | 18.31 | 361.29 | 252.29 | 269.38 | 0.00 | 0.00 | 0.00 |
June | 419.63 | 26.31 | 393.31 | 354.31 | 214.99 | 0.00 | 0.00 | 0.00 |
July | 398.04 | 22.69 | 375.34 | 357.27 | 199.89 | 0.00 | 0.00 | 0.00 |
August | 312.88 | 4.90 | 307.98 | 275.56 | 222.89 | 0.00 | 0.00 | 0.00 |
September | 238.14 | 0.05 | 238.09 | 179.48 | 299.12 | 0.00 | 0.00 | 0.00 |
October | 152.60 | 0.00 | 152.60 | 64.40 | 389.45 | 0.00 | 0.00 | 0.00 |
November | 91.69 | 0.00 | 91.69 | 10.09 | 470.69 | 0.00 | 0.00 | 0.00 |
December | 62.44 | 0.00 | 62.44 | 0.35 | 566.61 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 230.94 | 6.18 | 224.77 | 150.30 | 362.99 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 62.44 | 0.00 | 62.44 | 0.35 | 199.89 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 419.63 | 26.31 | 393.31 | 357.27 | 566.61 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 86.30 | 0.00 | 86.30 | 7.27 | 517.82 | 0.00 | 0.00 | 0.00 |
February | 134.76 | 0.00 | 134.76 | 22.38 | 486.43 | 0.00 | 0.00 | 0.00 |
March | 186.49 | 0.00 | 186.49 | 69.36 | 397.20 | 0.00 | 0.00 | 0.00 |
April | 303.63 | 1.36 | 302.27 | 203.21 | 328.98 | 0.00 | 0.00 | 0.00 |
May | 379.62 | 18.31 | 361.30 | 252.29 | 269.40 | 0.00 | 0.00 | 0.00 |
June | 419.64 | 26.31 | 393.33 | 354.32 | 215.00 | 0.00 | 0.00 | 0.00 |
July | 398.05 | 22.69 | 375.36 | 357.28 | 199.90 | 0.00 | 0.00 | 0.00 |
August | 312.89 | 4.90 | 307.99 | 275.57 | 222.91 | 0.00 | 0.00 | 0.00 |
September | 238.15 | 0.05 | 238.10 | 179.48 | 299.13 | 0.00 | 0.00 | 0.00 |
October | 152.61 | 0.00 | 152.61 | 64.40 | 389.48 | 0.00 | 0.00 | 0.00 |
November | 91.69 | 0.00 | 91.69 | 10.09 | 470.72 | 0.00 | 0.00 | 0.00 |
December | 62.44 | 0.00 | 62.44 | 0.35 | 566.65 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 230.95 | 6.18 | 224.77 | 150.31 | 363.01 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 62.44 | 0.00 | 62.44 | 0.35 | 199.90 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 419.64 | 26.31 | 393.33 | 357.28 | 566.65 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 86.30 | 0.00 | 86.30 | 7.27 | 517.82 | 0.00 | 0.00 | 0.00 |
February | 134.76 | 0.00 | 134.76 | 22.38 | 486.43 | 0.00 | 0.00 | 0.00 |
March | 186.49 | 0.00 | 186.49 | 69.36 | 397.20 | 0.00 | 0.00 | 0.00 |
April | 303.63 | 1.36 | 302.27 | 203.21 | 328.98 | 0.00 | 0.00 | 0.00 |
May | 379.62 | 18.31 | 361.30 | 252.29 | 269.40 | 0.00 | 0.00 | 0.00 |
June | 419.64 | 26.31 | 393.33 | 354.32 | 215.00 | 0.00 | 0.00 | 0.00 |
July | 398.05 | 22.69 | 375.36 | 357.28 | 199.90 | 0.00 | 0.00 | 0.00 |
August | 312.89 | 4.90 | 307.99 | 275.57 | 222.91 | 0.00 | 0.00 | 0.00 |
September | 238.15 | 0.05 | 238.10 | 179.48 | 299.13 | 0.00 | 0.00 | 0.00 |
October | 152.61 | 0.00 | 152.61 | 64.40 | 389.48 | 0.00 | 0.00 | 0.00 |
November | 91.69 | 0.00 | 91.69 | 10.09 | 470.72 | 0.00 | 0.00 | 0.00 |
December | 62.44 | 0.00 | 62.44 | 0.35 | 566.65 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 230.95 | 6.18 | 224.77 | 150.31 | 363.01 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 62.44 | 0.00 | 62.44 | 0.35 | 199.90 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 419.64 | 26.31 | 393.33 | 357.28 | 566.65 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 339.37 | 136.33 | 203.05 | 202.93 | 942.05 | 0.00 | 0.00 | 0.00 |
February | 506.07 | 186.94 | 319.12 | 335.40 | 895.88 | 0.00 | 0.00 | 0.00 |
March | 528.85 | 104.22 | 424.63 | 337.34 | 730.77 | 0.00 | 0.00 | 0.00 |
April | 1420.01 | 667.27 | 752.74 | 1486.77 | 629.67 | 0.00 | 0.00 | 0.00 |
May | 1493.09 | 651.11 | 841.98 | 1515.72 | 552.40 | 0.00 | 0.00 | 0.00 |
June | 1477.89 | 590.25 | 887.64 | 1598.84 | 435.48 | 0.00 | 0.00 | 0.00 |
July | 1508.63 | 641.17 | 867.47 | 1701.68 | 407.70 | 0.00 | 0.00 | 0.00 |
August | 1429.10 | 682.81 | 746.29 | 1660.46 | 444.04 | 0.00 | 0.00 | 0.00 |
September | 1286.95 | 684.34 | 602.61 | 1442.44 | 569.16 | 0.00 | 0.00 | 0.00 |
October | 621.23 | 257.45 | 363.78 | 547.23 | 735.22 | 0.00 | 0.00 | 0.00 |
November | 323.86 | 110.38 | 213.49 | 187.53 | 868.08 | 0.00 | 0.00 | 0.00 |
December | 240.02 | 89.24 | 150.79 | 122.74 | 1039.38 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 932.60 | 400.64 | 531.96 | 930.38 | 686.45 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 240.02 | 89.24 | 150.79 | 122.74 | 407.70 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1508.63 | 684.34 | 887.64 | 1701.68 | 1039.38 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 13.42 | 5.39 | 8.03 | 8.02 | 37.25 | 0.00 | 0.00 | 0.00 |
February | 20.01 | 7.39 | 12.62 | 13.26 | 35.42 | 0.00 | 0.00 | 0.00 |
March | 20.91 | 4.12 | 16.79 | 13.34 | 28.89 | 0.00 | 0.00 | 0.00 |
April | 56.15 | 26.38 | 29.76 | 58.79 | 24.90 | 0.00 | 0.00 | 0.00 |
May | 59.04 | 25.74 | 33.29 | 59.93 | 21.84 | 0.00 | 0.00 | 0.00 |
June | 58.43 | 23.34 | 35.10 | 63.22 | 17.22 | 0.00 | 0.00 | 0.00 |
July | 59.65 | 25.35 | 34.30 | 67.28 | 16.12 | 0.00 | 0.00 | 0.00 |
August | 56.51 | 27.00 | 29.51 | 65.65 | 17.56 | 0.00 | 0.00 | 0.00 |
September | 50.88 | 27.06 | 23.83 | 57.03 | 22.50 | 0.00 | 0.00 | 0.00 |
October | 24.56 | 10.18 | 14.38 | 21.64 | 29.07 | 0.00 | 0.00 | 0.00 |
November | 12.81 | 4.36 | 8.44 | 7.41 | 34.32 | 0.00 | 0.00 | 0.00 |
December | 9.49 | 3.53 | 5.96 | 4.85 | 41.10 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 36.87 | 15.84 | 21.03 | 36.79 | 27.14 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 9.49 | 3.53 | 5.96 | 4.85 | 16.12 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 59.65 | 27.06 | 35.10 | 67.28 | 41.10 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 489.96 | 317.17 | 172.79 | 491.99 | 473.95 | 0.00 | 0.00 | 0.00 |
February | 598.39 | 365.15 | 233.25 | 615.79 | 470.94 | 0.00 | 0.00 | 0.00 |
March | 369.97 | 107.72 | 262.25 | 313.11 | 383.81 | 0.00 | 0.00 | 0.00 |
April | 768.26 | 347.24 | 421.02 | 883.42 | 352.76 | 0.00 | 0.00 | 0.00 |
May | 635.43 | 206.87 | 428.55 | 676.60 | 306.65 | 0.00 | 0.00 | 0.00 |
June | 585.36 | 141.69 | 443.67 | 648.66 | 237.76 | 0.00 | 0.00 | 0.00 |
July | 634.23 | 198.62 | 435.62 | 751.92 | 225.53 | 0.00 | 0.00 | 0.00 |
August | 743.18 | 334.31 | 408.87 | 930.15 | 249.77 | 0.00 | 0.00 | 0.00 |
September | 878.24 | 514.49 | 363.75 | 1085.63 | 320.69 | 0.00 | 0.00 | 0.00 |
October | 603.39 | 352.65 | 250.74 | 667.41 | 394.56 | 0.00 | 0.00 | 0.00 |
November | 427.80 | 260.24 | 167.56 | 429.33 | 452.46 | 0.00 | 0.00 | 0.00 |
December | 339.07 | 217.24 | 121.83 | 330.14 | 533.11 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 588.54 | 279.19 | 309.35 | 651.11 | 366.26 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 339.07 | 107.72 | 121.83 | 313.11 | 225.53 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 878.24 | 514.49 | 443.67 | 1085.63 | 533.11 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 489.96 | 317.17 | 172.79 | 491.99 | 473.95 | 0.00 | 0.00 | 0.00 |
February | 598.39 | 365.15 | 233.25 | 615.79 | 470.94 | 0.00 | 0.00 | 0.00 |
March | 369.97 | 107.72 | 262.25 | 313.11 | 383.81 | 0.00 | 0.00 | 0.00 |
April | 768.26 | 347.24 | 421.02 | 883.42 | 352.76 | 0.00 | 0.00 | 0.00 |
May | 635.43 | 206.87 | 428.55 | 676.60 | 306.65 | 0.00 | 0.00 | 0.00 |
June | 585.36 | 141.69 | 443.67 | 648.66 | 237.76 | 0.00 | 0.00 | 0.00 |
July | 634.23 | 198.62 | 435.62 | 751.92 | 225.53 | 0.00 | 0.00 | 0.00 |
August | 743.18 | 334.31 | 408.87 | 930.15 | 249.77 | 0.00 | 0.00 | 0.00 |
September | 878.24 | 514.49 | 363.75 | 1085.63 | 320.69 | 0.00 | 0.00 | 0.00 |
October | 603.39 | 352.65 | 250.74 | 667.41 | 394.56 | 0.00 | 0.00 | 0.00 |
November | 427.80 | 260.24 | 167.56 | 429.33 | 452.46 | 0.00 | 0.00 | 0.00 |
December | 339.07 | 217.24 | 121.83 | 330.14 | 533.11 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 588.54 | 279.19 | 309.35 | 651.11 | 366.26 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 339.07 | 107.72 | 121.83 | 313.11 | 225.53 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 878.24 | 514.49 | 443.67 | 1085.63 | 533.11 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 489.92 | 317.15 | 172.78 | 491.96 | 473.92 | 0.00 | 0.00 | 0.00 |
February | 598.35 | 365.12 | 233.23 | 615.75 | 470.91 | 0.00 | 0.00 | 0.00 |
March | 369.94 | 107.71 | 262.23 | 313.09 | 383.79 | 0.00 | 0.00 | 0.00 |
April | 768.22 | 347.22 | 420.99 | 883.36 | 352.74 | 0.00 | 0.00 | 0.00 |
May | 635.39 | 206.86 | 428.53 | 676.55 | 306.63 | 0.00 | 0.00 | 0.00 |
June | 585.33 | 141.68 | 443.65 | 648.62 | 237.75 | 0.00 | 0.00 | 0.00 |
July | 634.19 | 198.60 | 435.59 | 751.87 | 225.51 | 0.00 | 0.00 | 0.00 |
August | 743.13 | 334.29 | 408.85 | 930.09 | 249.75 | 0.00 | 0.00 | 0.00 |
September | 878.19 | 514.45 | 363.73 | 1085.56 | 320.67 | 0.00 | 0.00 | 0.00 |
October | 603.35 | 352.63 | 250.72 | 667.37 | 394.54 | 0.00 | 0.00 | 0.00 |
November | 427.77 | 260.23 | 167.55 | 429.31 | 452.43 | 0.00 | 0.00 | 0.00 |
December | 339.05 | 217.23 | 121.82 | 330.11 | 533.07 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 588.50 | 279.18 | 309.33 | 651.06 | 366.24 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 339.05 | 107.71 | 121.82 | 313.09 | 225.51 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 878.19 | 514.45 | 443.65 | 1085.56 | 533.07 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 330.03 | 109.04 | 220.98 | 204.56 | 958.78 | 0.00 | 0.00 | 0.00 |
February | 584.33 | 246.72 | 337.61 | 470.42 | 926.13 | 0.00 | 0.00 | 0.00 |
March | 528.36 | 101.07 | 427.28 | 340.12 | 742.03 | 0.00 | 0.00 | 0.00 |
April | 1246.68 | 495.19 | 751.49 | 1293.29 | 660.75 | 0.00 | 0.00 | 0.00 |
May | 1462.64 | 594.76 | 867.88 | 1496.94 | 581.84 | 0.00 | 0.00 | 0.00 |
June | 1579.49 | 650.22 | 929.28 | 1742.81 | 465.50 | 0.00 | 0.00 | 0.00 |
July | 1608.65 | 709.25 | 899.39 | 1852.60 | 436.16 | 0.00 | 0.00 | 0.00 |
August | 1351.16 | 585.01 | 766.14 | 1572.66 | 475.14 | 0.00 | 0.00 | 0.00 |
September | 1083.99 | 486.08 | 597.90 | 1208.80 | 600.82 | 0.00 | 0.00 | 0.00 |
October | 578.26 | 207.94 | 370.32 | 509.17 | 753.52 | 0.00 | 0.00 | 0.00 |
November | 312.94 | 91.35 | 221.59 | 193.03 | 891.64 | 0.00 | 0.00 | 0.00 |
December | 177.13 | 37.38 | 139.75 | 65.94 | 1075.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 904.59 | 359.65 | 544.95 | 914.00 | 712.86 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 177.13 | 37.38 | 139.75 | 65.94 | 436.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1608.65 | 709.25 | 929.28 | 1852.60 | 1075.16 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 13.05 | 4.31 | 8.74 | 8.09 | 37.91 | 0.00 | 0.00 | 0.00 |
February | 23.10 | 9.76 | 13.35 | 18.60 | 36.62 | 0.00 | 0.00 | 0.00 |
March | 20.89 | 4.00 | 16.89 | 13.45 | 29.34 | 0.00 | 0.00 | 0.00 |
April | 49.29 | 19.58 | 29.71 | 51.14 | 26.13 | 0.00 | 0.00 | 0.00 |
May | 57.83 | 23.52 | 34.32 | 59.19 | 23.01 | 0.00 | 0.00 | 0.00 |
June | 62.45 | 25.71 | 36.74 | 68.91 | 18.41 | 0.00 | 0.00 | 0.00 |
July | 63.60 | 28.04 | 35.56 | 73.25 | 17.25 | 0.00 | 0.00 | 0.00 |
August | 53.42 | 23.13 | 30.29 | 62.18 | 18.79 | 0.00 | 0.00 | 0.00 |
September | 42.86 | 19.22 | 23.64 | 47.79 | 23.76 | 0.00 | 0.00 | 0.00 |
October | 22.86 | 8.22 | 14.64 | 20.13 | 29.79 | 0.00 | 0.00 | 0.00 |
November | 12.37 | 3.61 | 8.76 | 7.63 | 35.25 | 0.00 | 0.00 | 0.00 |
December | 7.00 | 1.48 | 5.53 | 2.61 | 42.51 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 35.77 | 14.22 | 21.55 | 36.14 | 28.19 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 7.00 | 1.48 | 5.53 | 2.61 | 17.25 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 63.60 | 28.04 | 36.74 | 73.25 | 42.51 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 258.91 | 0.00 | 258.91 | 18.72 | 1579.45 | 0.00 | 0.00 | 0.00 |
February | 404.29 | 0.00 | 404.29 | 58.32 | 1493.39 | 0.00 | 0.00 | 0.00 |
March | 559.47 | 0.00 | 559.47 | 188.59 | 1227.34 | 0.00 | 0.00 | 0.00 |
April | 910.90 | 4.08 | 906.83 | 565.08 | 1035.43 | 0.00 | 0.00 | 0.00 |
May | 1138.86 | 54.94 | 1083.92 | 709.74 | 841.20 | 0.00 | 0.00 | 0.00 |
June | 1258.94 | 78.94 | 1180.00 | 1025.93 | 666.41 | 0.00 | 0.00 | 0.00 |
July | 1194.17 | 68.09 | 1126.09 | 1043.30 | 615.10 | 0.00 | 0.00 | 0.00 |
August | 938.68 | 14.71 | 923.97 | 801.54 | 688.50 | 0.00 | 0.00 | 0.00 |
September | 714.47 | 0.16 | 714.31 | 520.14 | 915.65 | 0.00 | 0.00 | 0.00 |
October | 457.82 | 0.00 | 457.82 | 183.72 | 1177.17 | 0.00 | 0.00 | 0.00 |
November | 275.08 | 0.00 | 275.08 | 28.54 | 1412.26 | 0.00 | 0.00 | 0.00 |
December | 187.33 | 0.00 | 187.33 | 1.03 | 1700.79 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 692.86 | 18.53 | 674.33 | 430.60 | 1110.75 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 187.33 | 0.00 | 187.33 | 1.03 | 615.10 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1258.94 | 78.94 | 1180.00 | 1043.30 | 1700.79 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_2_WALL_EAST_WINDOW
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 352.80 | 141.72 | 211.08 | 206.59 | 988.73 | 0.00 | 0.00 | 0.00 |
February | 526.08 | 194.34 | 331.74 | 340.30 | 943.95 | 0.00 | 0.00 | 0.00 |
March | 549.77 | 108.34 | 441.43 | 337.64 | 775.87 | 0.00 | 0.00 | 0.00 |
April | 1476.18 | 693.66 | 782.51 | 1527.79 | 655.95 | 0.00 | 0.00 | 0.00 |
May | 1552.15 | 676.87 | 875.29 | 1559.51 | 571.65 | 0.00 | 0.00 | 0.00 |
June | 1536.35 | 613.60 | 922.74 | 1647.28 | 451.63 | 0.00 | 0.00 | 0.00 |
July | 1568.31 | 666.53 | 901.78 | 1757.85 | 418.26 | 0.00 | 0.00 | 0.00 |
August | 1485.63 | 709.82 | 775.81 | 1716.81 | 453.67 | 0.00 | 0.00 | 0.00 |
September | 1337.86 | 711.41 | 626.45 | 1493.08 | 576.98 | 0.00 | 0.00 | 0.00 |
October | 645.80 | 267.64 | 378.16 | 565.86 | 752.19 | 0.00 | 0.00 | 0.00 |
November | 336.68 | 114.74 | 221.93 | 193.30 | 894.80 | 0.00 | 0.00 | 0.00 |
December | 249.52 | 92.77 | 156.75 | 126.28 | 1079.28 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 969.49 | 416.49 | 553.01 | 958.24 | 712.44 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 249.52 | 92.77 | 156.75 | 126.28 | 418.26 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1568.31 | 711.41 | 922.74 | 1757.85 | 1079.28 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1469.89 | 951.52 | 518.37 | 1451.67 | 1435.84 | 0.00 | 0.00 | 0.00 |
February | 1795.21 | 1095.46 | 699.75 | 1814.33 | 1422.99 | 0.00 | 0.00 | 0.00 |
March | 1109.91 | 323.16 | 786.76 | 897.80 | 1190.34 | 0.00 | 0.00 | 0.00 |
April | 2304.83 | 1041.76 | 1263.07 | 2604.12 | 1074.67 | 0.00 | 0.00 | 0.00 |
May | 1906.31 | 620.63 | 1285.68 | 1981.27 | 943.86 | 0.00 | 0.00 | 0.00 |
June | 1756.12 | 425.08 | 1331.03 | 1901.16 | 734.62 | 0.00 | 0.00 | 0.00 |
July | 1902.72 | 595.86 | 1306.86 | 2224.58 | 683.18 | 0.00 | 0.00 | 0.00 |
August | 2229.57 | 1002.94 | 1226.63 | 2767.37 | 741.23 | 0.00 | 0.00 | 0.00 |
September | 2634.77 | 1543.49 | 1091.28 | 3239.63 | 933.76 | 0.00 | 0.00 | 0.00 |
October | 1810.19 | 1057.98 | 752.22 | 1985.94 | 1161.30 | 0.00 | 0.00 | 0.00 |
November | 1283.43 | 780.74 | 502.69 | 1269.85 | 1348.36 | 0.00 | 0.00 | 0.00 |
December | 1017.23 | 651.75 | 365.49 | 973.87 | 1614.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1765.65 | 837.60 | 928.05 | 1923.29 | 1105.35 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 1017.23 | 323.16 | 365.49 | 897.80 | 683.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2634.77 | 1543.49 | 1331.03 | 3239.63 | 1614.12 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_4_WALL_WEST_WINDOW
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 343.08 | 113.35 | 229.72 | 207.31 | 1007.41 | 0.00 | 0.00 | 0.00 |
February | 607.44 | 256.48 | 350.96 | 478.98 | 974.13 | 0.00 | 0.00 | 0.00 |
March | 549.26 | 105.07 | 444.18 | 338.00 | 789.10 | 0.00 | 0.00 | 0.00 |
April | 1295.99 | 514.78 | 781.21 | 1322.57 | 697.00 | 0.00 | 0.00 | 0.00 |
May | 1520.49 | 618.28 | 902.21 | 1536.60 | 607.12 | 0.00 | 0.00 | 0.00 |
June | 1641.97 | 675.94 | 966.03 | 1795.66 | 482.31 | 0.00 | 0.00 | 0.00 |
July | 1672.27 | 737.31 | 934.96 | 1912.49 | 449.49 | 0.00 | 0.00 | 0.00 |
August | 1404.60 | 608.15 | 796.45 | 1623.40 | 488.84 | 0.00 | 0.00 | 0.00 |
September | 1126.86 | 505.31 | 621.55 | 1249.20 | 616.74 | 0.00 | 0.00 | 0.00 |
October | 601.14 | 216.17 | 384.97 | 524.61 | 776.57 | 0.00 | 0.00 | 0.00 |
November | 325.31 | 94.96 | 230.35 | 197.86 | 922.12 | 0.00 | 0.00 | 0.00 |
December | 184.14 | 38.86 | 145.28 | 67.17 | 1119.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 940.37 | 373.87 | 566.50 | 939.36 | 742.98 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 184.14 | 38.86 | 145.28 | 67.17 | 449.49 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1672.27 | 737.31 | 966.03 | 1912.49 | 1119.12 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.693455E+09 | 0.00 | 0.693455E+09 | 64693257.22 | 0.397457E+10 |
February | 0.978065E+09 | 0.00 | 0.978065E+09 | 0.172167E+09 | 0.337792E+10 |
March | 0.149848E+10 | 0.00 | 0.149848E+10 | 0.551687E+09 | 0.308073E+10 |
April | 0.236106E+10 | 10567121.51 | 0.235049E+10 | 0.151212E+10 | 0.252873E+10 |
May | 0.305033E+10 | 0.147164E+09 | 0.290316E+10 | 0.196675E+10 | 0.212779E+10 |
June | 0.326317E+10 | 0.204622E+09 | 0.305855E+10 | 0.269166E+10 | 0.165039E+10 |
July | 0.319847E+10 | 0.182362E+09 | 0.301611E+10 | 0.282362E+10 | 0.157773E+10 |
August | 0.251416E+10 | 39390701.15 | 0.247477E+10 | 0.217400E+10 | 0.175513E+10 |
September | 0.185189E+10 | 409786.82 | 0.185148E+10 | 0.139133E+10 | 0.222876E+10 |
October | 0.122624E+10 | 0.00 | 0.122624E+10 | 0.546158E+09 | 0.290592E+10 |
November | 0.713019E+09 | 0.00 | 0.713019E+09 | 95847264.98 | 0.338716E+10 |
December | 0.501749E+09 | 0.00 | 0.501749E+09 | 8192083.51 | 0.426589E+10 |
Annual Sum or Average | 0.218501E+11 | 0.584515E+09 | 0.212656E+11 | 0.139982E+11 | 0.328607E+11 |
Minimum of Months | 0.501749E+09 | 0.00 | 0.501749E+09 | 8192083.51 | 0.157773E+10 |
Maximum of Months | 0.326317E+10 | 0.204622E+09 | 0.305855E+10 | 0.282362E+10 | 0.426589E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.944935E+09 | 0.379582E+09 | 0.565353E+09 | 0.574715E+09 | 0.249311E+10 |
February | 0.127270E+10 | 0.470146E+09 | 0.802556E+09 | 0.854636E+09 | 0.214325E+10 |
March | 0.147250E+10 | 0.290176E+09 | 0.118233E+10 | 0.938978E+09 | 0.195520E+10 |
April | 0.382625E+10 | 0.179798E+10 | 0.202827E+10 | 0.398802E+10 | 0.161758E+10 |
May | 0.415728E+10 | 0.181292E+10 | 0.234436E+10 | 0.420704E+10 | 0.145810E+10 |
June | 0.398221E+10 | 0.159046E+10 | 0.239175E+10 | 0.428407E+10 | 0.112386E+10 |
July | 0.420055E+10 | 0.178523E+10 | 0.241532E+10 | 0.471858E+10 | 0.107824E+10 |
August | 0.397910E+10 | 0.190118E+10 | 0.207793E+10 | 0.460973E+10 | 0.116539E+10 |
September | 0.346773E+10 | 0.184398E+10 | 0.162375E+10 | 0.389396E+10 | 0.141946E+10 |
October | 0.172971E+10 | 0.716838E+09 | 0.101288E+10 | 0.155153E+10 | 0.187320E+10 |
November | 0.872663E+09 | 0.297416E+09 | 0.575247E+09 | 0.525048E+09 | 0.215726E+10 |
December | 0.668308E+09 | 0.248468E+09 | 0.419840E+09 | 0.354920E+09 | 0.271355E+10 |
Annual Sum or Average | 0.305739E+11 | 0.131344E+11 | 0.174396E+11 | 0.305012E+11 | 0.211982E+11 |
Minimum of Months | 0.668308E+09 | 0.248468E+09 | 0.419840E+09 | 0.354920E+09 | 0.107824E+10 |
Maximum of Months | 0.420055E+10 | 0.190118E+10 | 0.241532E+10 | 0.471858E+10 | 0.271355E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.393696E+10 | 0.254856E+10 | 0.138841E+10 | 0.393657E+10 | 0.361659E+10 |
February | 0.434296E+10 | 0.265013E+10 | 0.169283E+10 | 0.444287E+10 | 0.323297E+10 |
March | 0.297279E+10 | 0.865544E+09 | 0.210725E+10 | 0.246173E+10 | 0.299395E+10 |
April | 0.597411E+10 | 0.270023E+10 | 0.327388E+10 | 0.678528E+10 | 0.263985E+10 |
May | 0.510585E+10 | 0.166230E+10 | 0.344355E+10 | 0.534703E+10 | 0.238988E+10 |
June | 0.455185E+10 | 0.110181E+10 | 0.345004E+10 | 0.495170E+10 | 0.181516E+10 |
July | 0.509624E+10 | 0.159594E+10 | 0.350030E+10 | 0.597560E+10 | 0.174812E+10 |
August | 0.597167E+10 | 0.268628E+10 | 0.328539E+10 | 0.742786E+10 | 0.189119E+10 |
September | 0.682932E+10 | 0.400073E+10 | 0.282859E+10 | 0.842619E+10 | 0.228883E+10 |
October | 0.484842E+10 | 0.283368E+10 | 0.201474E+10 | 0.537155E+10 | 0.288804E+10 |
November | 0.332664E+10 | 0.202368E+10 | 0.130296E+10 | 0.333903E+10 | 0.324832E+10 |
December | 0.272456E+10 | 0.174564E+10 | 0.978921E+09 | 0.264797E+10 | 0.405921E+10 |
Annual Sum or Average | 0.556814E+11 | 0.264145E+11 | 0.292669E+11 | 0.611134E+11 | 0.328121E+11 |
Minimum of Months | 0.272456E+10 | 0.865544E+09 | 0.978921E+09 | 0.246173E+10 | 0.174812E+10 |
Maximum of Months | 0.682932E+10 | 0.400073E+10 | 0.350030E+10 | 0.842619E+10 | 0.405921E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.918904E+09 | 0.303610E+09 | 0.615294E+09 | 0.571799E+09 | 0.253855E+10 |
February | 0.146952E+10 | 0.620477E+09 | 0.849039E+09 | 0.118316E+10 | 0.220988E+10 |
March | 0.147112E+10 | 0.281426E+09 | 0.118970E+10 | 0.936066E+09 | 0.198422E+10 |
April | 0.335920E+10 | 0.133430E+10 | 0.202489E+10 | 0.345680E+10 | 0.170975E+10 |
May | 0.407248E+10 | 0.165601E+10 | 0.241647E+10 | 0.414669E+10 | 0.153781E+10 |
June | 0.425598E+10 | 0.175202E+10 | 0.250395E+10 | 0.466981E+10 | 0.119183E+10 |
July | 0.447901E+10 | 0.197481E+10 | 0.250420E+10 | 0.513424E+10 | 0.115028E+10 |
August | 0.376207E+10 | 0.162887E+10 | 0.213320E+10 | 0.436261E+10 | 0.124617E+10 |
September | 0.292082E+10 | 0.130976E+10 | 0.161106E+10 | 0.326524E+10 | 0.150559E+10 |
October | 0.161008E+10 | 0.578979E+09 | 0.103110E+10 | 0.143914E+10 | 0.192917E+10 |
November | 0.843214E+09 | 0.246145E+09 | 0.597069E+09 | 0.530884E+09 | 0.222081E+10 |
December | 0.493193E+09 | 0.104075E+09 | 0.389119E+09 | 0.189375E+09 | 0.281346E+10 |
Annual Sum or Average | 0.296556E+11 | 0.117905E+11 | 0.178651E+11 | 0.298858E+11 | 0.220375E+11 |
Minimum of Months | 0.493193E+09 | 0.104075E+09 | 0.389119E+09 | 0.189375E+09 | 0.115028E+10 |
Maximum of Months | 0.447901E+10 | 0.197481E+10 | 0.250420E+10 | 0.513424E+10 | 0.281346E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.231141E+09 | 0.00 | 0.231141E+09 | 19466127.85 | 0.138685E+10 |
February | 0.326006E+09 | 0.00 | 0.326006E+09 | 54155212.77 | 0.117671E+10 |
March | 0.499471E+09 | 0.00 | 0.499471E+09 | 0.185788E+09 | 0.106380E+10 |
April | 0.786983E+09 | 3522207.19 | 0.783461E+09 | 0.526712E+09 | 0.852656E+09 |
May | 0.101673E+10 | 49052190.66 | 0.967675E+09 | 0.675724E+09 | 0.721515E+09 |
June | 0.108767E+10 | 68204100.91 | 0.101947E+10 | 0.918374E+09 | 0.557254E+09 |
July | 0.106611E+10 | 60784394.63 | 0.100532E+10 | 0.956917E+09 | 0.535391E+09 |
August | 0.838015E+09 | 13129612.50 | 0.824885E+09 | 0.738056E+09 | 0.596998E+09 |
September | 0.617269E+09 | 136589.14 | 0.617132E+09 | 0.465203E+09 | 0.775308E+09 |
October | 0.408726E+09 | 0.00 | 0.408726E+09 | 0.172481E+09 | 0.104311E+10 |
November | 0.237662E+09 | 0.00 | 0.237662E+09 | 26146507.65 | 0.122004E+10 |
December | 0.167242E+09 | 0.00 | 0.167242E+09 | 949983.89 | 0.151761E+10 |
Annual Sum or Average | 0.728302E+10 | 0.194829E+09 | 0.708819E+10 | 0.473997E+10 | 0.114472E+11 |
Minimum of Months | 0.167242E+09 | 0.00 | 0.167242E+09 | 949983.89 | 0.535391E+09 |
Maximum of Months | 0.108767E+10 | 68204100.91 | 0.101947E+10 | 0.956917E+09 | 0.151761E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.231149E+09 | 0.00 | 0.231149E+09 | 19465070.80 | 0.138694E+10 |
February | 0.326019E+09 | 0.00 | 0.326019E+09 | 54153024.82 | 0.117678E+10 |
March | 0.499489E+09 | 0.00 | 0.499489E+09 | 0.185786E+09 | 0.106387E+10 |
April | 0.787014E+09 | 3522301.86 | 0.783492E+09 | 0.526725E+09 | 0.852709E+09 |
May | 0.101677E+10 | 49053509.20 | 0.967713E+09 | 0.675737E+09 | 0.721560E+09 |
June | 0.108771E+10 | 68205934.26 | 0.101951E+10 | 0.918398E+09 | 0.557287E+09 |
July | 0.106615E+10 | 60786028.54 | 0.100536E+10 | 0.956945E+09 | 0.535423E+09 |
August | 0.838049E+09 | 13129965.42 | 0.824919E+09 | 0.738081E+09 | 0.597033E+09 |
September | 0.617294E+09 | 136592.81 | 0.617157E+09 | 0.465217E+09 | 0.775354E+09 |
October | 0.408742E+09 | 0.00 | 0.408742E+09 | 0.172482E+09 | 0.104318E+10 |
November | 0.237670E+09 | 0.00 | 0.237670E+09 | 26145185.08 | 0.122012E+10 |
December | 0.167248E+09 | 0.00 | 0.167248E+09 | 949658.67 | 0.151771E+10 |
Annual Sum or Average | 0.728330E+10 | 0.194834E+09 | 0.708847E+10 | 0.474008E+10 | 0.114480E+11 |
Minimum of Months | 0.167248E+09 | 0.00 | 0.167248E+09 | 949658.67 | 0.535423E+09 |
Maximum of Months | 0.108771E+10 | 68205934.26 | 0.101951E+10 | 0.956945E+09 | 0.151771E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.231149E+09 | 0.00 | 0.231149E+09 | 19465070.80 | 0.138694E+10 |
February | 0.326019E+09 | 0.00 | 0.326019E+09 | 54153024.82 | 0.117678E+10 |
March | 0.499489E+09 | 0.00 | 0.499489E+09 | 0.185786E+09 | 0.106387E+10 |
April | 0.787014E+09 | 3522301.86 | 0.783492E+09 | 0.526725E+09 | 0.852709E+09 |
May | 0.101677E+10 | 49053509.20 | 0.967713E+09 | 0.675737E+09 | 0.721560E+09 |
June | 0.108771E+10 | 68205934.26 | 0.101951E+10 | 0.918398E+09 | 0.557287E+09 |
July | 0.106615E+10 | 60786028.54 | 0.100536E+10 | 0.956945E+09 | 0.535423E+09 |
August | 0.838049E+09 | 13129965.42 | 0.824919E+09 | 0.738081E+09 | 0.597033E+09 |
September | 0.617294E+09 | 136592.81 | 0.617157E+09 | 0.465217E+09 | 0.775354E+09 |
October | 0.408742E+09 | 0.00 | 0.408742E+09 | 0.172482E+09 | 0.104318E+10 |
November | 0.237670E+09 | 0.00 | 0.237670E+09 | 26145185.08 | 0.122012E+10 |
December | 0.167248E+09 | 0.00 | 0.167248E+09 | 949658.67 | 0.151771E+10 |
Annual Sum or Average | 0.728330E+10 | 0.194834E+09 | 0.708847E+10 | 0.474008E+10 | 0.114480E+11 |
Minimum of Months | 0.167248E+09 | 0.00 | 0.167248E+09 | 949658.67 | 0.535423E+09 |
Maximum of Months | 0.108771E+10 | 68205934.26 | 0.101951E+10 | 0.956945E+09 | 0.151771E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.908980E+09 | 0.365137E+09 | 0.543842E+09 | 0.543525E+09 | 0.252318E+10 |
February | 0.122428E+10 | 0.452255E+09 | 0.772020E+09 | 0.811411E+09 | 0.216732E+10 |
March | 0.141647E+10 | 0.279134E+09 | 0.113734E+10 | 0.903541E+09 | 0.195730E+10 |
April | 0.368065E+10 | 0.172956E+10 | 0.195110E+10 | 0.385370E+10 | 0.163210E+10 |
May | 0.399910E+10 | 0.174393E+10 | 0.225517E+10 | 0.405970E+10 | 0.147956E+10 |
June | 0.383069E+10 | 0.152993E+10 | 0.230076E+10 | 0.414419E+10 | 0.112876E+10 |
July | 0.404072E+10 | 0.171730E+10 | 0.232342E+10 | 0.455777E+10 | 0.109197E+10 |
August | 0.382770E+10 | 0.182883E+10 | 0.199887E+10 | 0.444737E+10 | 0.118933E+10 |
September | 0.333578E+10 | 0.177381E+10 | 0.156197E+10 | 0.373881E+10 | 0.147526E+10 |
October | 0.166390E+10 | 0.689560E+09 | 0.974338E+09 | 0.146570E+10 | 0.196921E+10 |
November | 0.839458E+09 | 0.286098E+09 | 0.553359E+09 | 0.486069E+09 | 0.225006E+10 |
December | 0.642878E+09 | 0.239012E+09 | 0.403866E+09 | 0.328744E+09 | 0.278388E+10 |
Annual Sum or Average | 0.294106E+11 | 0.126346E+11 | 0.167760E+11 | 0.293405E+11 | 0.216479E+11 |
Minimum of Months | 0.642878E+09 | 0.239012E+09 | 0.403866E+09 | 0.328744E+09 | 0.109197E+10 |
Maximum of Months | 0.404072E+10 | 0.182883E+10 | 0.232342E+10 | 0.455777E+10 | 0.278388E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 35940239.15 | 14437204.89 | 21503034.26 | 21490482.50 | 99764360.75 |
February | 48406731.90 | 17881744.77 | 30524987.13 | 32082470.31 | 85693846.75 |
March | 56006058.90 | 11036702.52 | 44969356.38 | 35725209.78 | 77389831.49 |
April | 0.145530E+09 | 68385164.57 | 77144613.80 | 0.152372E+09 | 64531898.45 |
May | 0.158121E+09 | 68953464.77 | 89167261.40 | 0.160517E+09 | 58500367.55 |
June | 0.151462E+09 | 60492136.94 | 90969782.63 | 0.163858E+09 | 44629985.99 |
July | 0.159766E+09 | 67900410.63 | 91866013.04 | 0.180210E+09 | 43175588.23 |
August | 0.151344E+09 | 72310336.11 | 79033396.67 | 0.175845E+09 | 47024866.89 |
September | 0.131894E+09 | 70134807.01 | 61758862.23 | 0.147829E+09 | 58330407.38 |
October | 65789025.65 | 27264569.16 | 38524456.48 | 57952282.26 | 77860876.74 |
November | 33191402.08 | 11312070.14 | 21879331.94 | 19218747.68 | 88965345.20 |
December | 25418824.06 | 9450332.80 | 15968491.26 | 12998240.15 | 0.110072E+09 |
Annual Sum or Average | 0.116287E+10 | 0.499559E+09 | 0.663310E+09 | 0.116010E+10 | 0.855939E+09 |
Minimum of Months | 25418824.06 | 9450332.80 | 15968491.26 | 12998240.15 | 43175588.23 |
Maximum of Months | 0.159766E+09 | 72310336.11 | 91866013.04 | 0.180210E+09 | 0.110072E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.131230E+10 | 0.849502E+09 | 0.462795E+09 | 0.131775E+10 | 0.126942E+10 |
February | 0.144763E+10 | 0.883360E+09 | 0.564267E+09 | 0.148971E+10 | 0.113929E+10 |
March | 0.990915E+09 | 0.288509E+09 | 0.702407E+09 | 0.838627E+09 | 0.102800E+10 |
April | 0.199134E+10 | 0.900058E+09 | 0.109128E+10 | 0.228982E+10 | 0.914363E+09 |
May | 0.170193E+10 | 0.554088E+09 | 0.114784E+10 | 0.181220E+10 | 0.821322E+09 |
June | 0.151727E+10 | 0.367263E+09 | 0.115000E+10 | 0.168132E+10 | 0.616283E+09 |
July | 0.169872E+10 | 0.531971E+09 | 0.116675E+10 | 0.201393E+10 | 0.604051E+09 |
August | 0.199053E+10 | 0.895409E+09 | 0.109512E+10 | 0.249132E+10 | 0.668984E+09 |
September | 0.227640E+10 | 0.133355E+10 | 0.942852E+09 | 0.281394E+10 | 0.831226E+09 |
October | 0.161611E+10 | 0.944542E+09 | 0.671570E+09 | 0.178758E+10 | 0.105680E+10 |
November | 0.110886E+10 | 0.674547E+09 | 0.434314E+09 | 0.111283E+10 | 0.117277E+10 |
December | 0.908169E+09 | 0.581867E+09 | 0.326302E+09 | 0.884234E+09 | 0.142787E+10 |
Annual Sum or Average | 0.185602E+11 | 0.880467E+10 | 0.975550E+10 | 0.205333E+11 | 0.115504E+11 |
Minimum of Months | 0.908169E+09 | 0.288509E+09 | 0.326302E+09 | 0.838627E+09 | 0.604051E+09 |
Maximum of Months | 0.227640E+10 | 0.133355E+10 | 0.116675E+10 | 0.281394E+10 | 0.142787E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.131230E+10 | 0.849502E+09 | 0.462795E+09 | 0.131775E+10 | 0.126942E+10 |
February | 0.144763E+10 | 0.883360E+09 | 0.564267E+09 | 0.148971E+10 | 0.113929E+10 |
March | 0.990915E+09 | 0.288509E+09 | 0.702407E+09 | 0.838627E+09 | 0.102800E+10 |
April | 0.199134E+10 | 0.900058E+09 | 0.109128E+10 | 0.228982E+10 | 0.914363E+09 |
May | 0.170193E+10 | 0.554088E+09 | 0.114784E+10 | 0.181220E+10 | 0.821322E+09 |
June | 0.151727E+10 | 0.367263E+09 | 0.115000E+10 | 0.168132E+10 | 0.616283E+09 |
July | 0.169872E+10 | 0.531971E+09 | 0.116675E+10 | 0.201393E+10 | 0.604051E+09 |
August | 0.199053E+10 | 0.895409E+09 | 0.109512E+10 | 0.249132E+10 | 0.668984E+09 |
September | 0.227640E+10 | 0.133355E+10 | 0.942852E+09 | 0.281394E+10 | 0.831226E+09 |
October | 0.161611E+10 | 0.944542E+09 | 0.671570E+09 | 0.178758E+10 | 0.105680E+10 |
November | 0.110886E+10 | 0.674547E+09 | 0.434314E+09 | 0.111283E+10 | 0.117277E+10 |
December | 0.908169E+09 | 0.581867E+09 | 0.326302E+09 | 0.884234E+09 | 0.142787E+10 |
Annual Sum or Average | 0.185602E+11 | 0.880467E+10 | 0.975550E+10 | 0.205333E+11 | 0.115504E+11 |
Minimum of Months | 0.908169E+09 | 0.288509E+09 | 0.326302E+09 | 0.838627E+09 | 0.604051E+09 |
Maximum of Months | 0.227640E+10 | 0.133355E+10 | 0.116675E+10 | 0.281394E+10 | 0.142787E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.131221E+10 | 0.849448E+09 | 0.462765E+09 | 0.131766E+10 | 0.126934E+10 |
February | 0.144754E+10 | 0.883304E+09 | 0.564232E+09 | 0.148962E+10 | 0.113922E+10 |
March | 0.990853E+09 | 0.288491E+09 | 0.702362E+09 | 0.838574E+09 | 0.102793E+10 |
April | 0.199121E+10 | 0.900001E+09 | 0.109121E+10 | 0.228967E+10 | 0.914306E+09 |
May | 0.170182E+10 | 0.554053E+09 | 0.114777E+10 | 0.181208E+10 | 0.821270E+09 |
June | 0.151717E+10 | 0.367240E+09 | 0.114993E+10 | 0.168121E+10 | 0.616244E+09 |
July | 0.169862E+10 | 0.531937E+09 | 0.116668E+10 | 0.201380E+10 | 0.604013E+09 |
August | 0.199040E+10 | 0.895352E+09 | 0.109505E+10 | 0.249116E+10 | 0.668942E+09 |
September | 0.227626E+10 | 0.133346E+10 | 0.942792E+09 | 0.281377E+10 | 0.831173E+09 |
October | 0.161601E+10 | 0.944483E+09 | 0.671528E+09 | 0.178747E+10 | 0.105673E+10 |
November | 0.110879E+10 | 0.674504E+09 | 0.434286E+09 | 0.111276E+10 | 0.117269E+10 |
December | 0.908112E+09 | 0.581831E+09 | 0.326281E+09 | 0.884178E+09 | 0.142778E+10 |
Annual Sum or Average | 0.185590E+11 | 0.880411E+10 | 0.975489E+10 | 0.205320E+11 | 0.115496E+11 |
Minimum of Months | 0.908112E+09 | 0.288491E+09 | 0.326281E+09 | 0.838574E+09 | 0.604013E+09 |
Maximum of Months | 0.227626E+10 | 0.133346E+10 | 0.116668E+10 | 0.281377E+10 | 0.142778E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.883941E+09 | 0.292057E+09 | 0.591884E+09 | 0.547892E+09 | 0.256800E+10 |
February | 0.141360E+10 | 0.596867E+09 | 0.816736E+09 | 0.113803E+10 | 0.224049E+10 |
March | 0.141515E+10 | 0.270718E+09 | 0.114443E+10 | 0.910986E+09 | 0.198746E+10 |
April | 0.323139E+10 | 0.128353E+10 | 0.194786E+10 | 0.335220E+10 | 0.171267E+10 |
May | 0.391754E+10 | 0.159300E+10 | 0.232454E+10 | 0.400940E+10 | 0.155841E+10 |
June | 0.409405E+10 | 0.168536E+10 | 0.240869E+10 | 0.451736E+10 | 0.120658E+10 |
July | 0.430860E+10 | 0.189967E+10 | 0.240893E+10 | 0.496201E+10 | 0.116822E+10 |
August | 0.361893E+10 | 0.156689E+10 | 0.205204E+10 | 0.421220E+10 | 0.127261E+10 |
September | 0.280969E+10 | 0.125992E+10 | 0.154977E+10 | 0.313321E+10 | 0.155732E+10 |
October | 0.154882E+10 | 0.556948E+09 | 0.991875E+09 | 0.136375E+10 | 0.201823E+10 |
November | 0.811131E+09 | 0.236779E+09 | 0.574353E+09 | 0.500332E+09 | 0.231112E+10 |
December | 0.474429E+09 | 0.100114E+09 | 0.374314E+09 | 0.176620E+09 | 0.287971E+10 |
Annual Sum or Average | 0.285273E+11 | 0.113419E+11 | 0.171854E+11 | 0.288240E+11 | 0.224808E+11 |
Minimum of Months | 0.474429E+09 | 0.100114E+09 | 0.374314E+09 | 0.176620E+09 | 0.116822E+10 |
Maximum of Months | 0.430860E+10 | 0.189967E+10 | 0.240893E+10 | 0.496201E+10 | 0.287971E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 34950143.05 | 11547628.87 | 23402514.17 | 21663064.37 | 0.101536E+09 |
February | 55892455.60 | 23599514.25 | 32292941.35 | 44996579.58 | 88587001.90 |
March | 55953690.29 | 10703896.48 | 45249793.81 | 36019389.46 | 78582395.69 |
April | 0.127766E+09 | 50749461.26 | 77016299.65 | 0.132543E+09 | 67717277.64 |
May | 0.154895E+09 | 62985575.77 | 91909834.13 | 0.158528E+09 | 61618140.45 |
June | 0.161875E+09 | 66637346.21 | 95237229.37 | 0.178612E+09 | 47706999.08 |
July | 0.170358E+09 | 75110828.46 | 95246719.66 | 0.196193E+09 | 46190182.60 |
August | 0.143089E+09 | 61953287.28 | 81135723.18 | 0.166546E+09 | 50317871.02 |
September | 0.111092E+09 | 49816103.70 | 61276194.12 | 0.123884E+09 | 61575008.97 |
October | 61238889.54 | 22021157.68 | 39217731.86 | 53921209.89 | 79798970.47 |
November | 32071318.67 | 9361983.52 | 22709335.16 | 19782592.32 | 91379779.47 |
December | 18758435.89 | 3958422.73 | 14800013.17 | 6983347.47 | 0.113861E+09 |
Annual Sum or Average | 0.112794E+10 | 0.448445E+09 | 0.679494E+09 | 0.113967E+10 | 0.888871E+09 |
Minimum of Months | 18758435.89 | 3958422.73 | 14800013.17 | 6983347.47 | 46190182.60 |
Maximum of Months | 0.170358E+09 | 75110828.46 | 95246719.66 | 0.196193E+09 | 0.113861E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.693455E+09 | 0.00 | 0.693455E+09 | 50144748.88 | 0.423039E+10 |
February | 0.978065E+09 | 0.00 | 0.978065E+09 | 0.141086E+09 | 0.361282E+10 |
March | 0.149848E+10 | 0.00 | 0.149848E+10 | 0.505108E+09 | 0.328729E+10 |
April | 0.236106E+10 | 10567121.51 | 0.235049E+10 | 0.146470E+10 | 0.268384E+10 |
May | 0.305033E+10 | 0.147164E+09 | 0.290316E+10 | 0.190096E+10 | 0.225308E+10 |
June | 0.326317E+10 | 0.204622E+09 | 0.305855E+10 | 0.265922E+10 | 0.172732E+10 |
July | 0.319847E+10 | 0.182362E+09 | 0.301611E+10 | 0.279437E+10 | 0.164748E+10 |
August | 0.251416E+10 | 39390701.15 | 0.247477E+10 | 0.214684E+10 | 0.184408E+10 |
September | 0.185189E+10 | 409786.82 | 0.185148E+10 | 0.134821E+10 | 0.237336E+10 |
October | 0.122624E+10 | 0.00 | 0.122624E+10 | 0.492076E+09 | 0.315293E+10 |
November | 0.713019E+09 | 0.00 | 0.713019E+09 | 73981112.28 | 0.366057E+10 |
December | 0.501749E+09 | 0.00 | 0.501749E+09 | 2746541.31 | 0.455540E+10 |
Annual Sum or Average | 0.218501E+11 | 0.584515E+09 | 0.212656E+11 | 0.135794E+11 | 0.350286E+11 |
Minimum of Months | 0.501749E+09 | 0.00 | 0.501749E+09 | 2746541.31 | 0.164748E+10 |
Maximum of Months | 0.326317E+10 | 0.204622E+09 | 0.305855E+10 | 0.279437E+10 | 0.455540E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_2_WALL_EAST_WINDOW
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.944935E+09 | 0.379582E+09 | 0.565353E+09 | 0.553330E+09 | 0.264823E+10 |
February | 0.127270E+10 | 0.470146E+09 | 0.802556E+09 | 0.823261E+09 | 0.228361E+10 |
March | 0.147250E+10 | 0.290176E+09 | 0.118233E+10 | 0.904336E+09 | 0.207810E+10 |
April | 0.382625E+10 | 0.179798E+10 | 0.202827E+10 | 0.396004E+10 | 0.170023E+10 |
May | 0.415728E+10 | 0.181292E+10 | 0.234436E+10 | 0.417699E+10 | 0.153112E+10 |
June | 0.398221E+10 | 0.159046E+10 | 0.239175E+10 | 0.426974E+10 | 0.117064E+10 |
July | 0.420055E+10 | 0.178523E+10 | 0.241532E+10 | 0.470824E+10 | 0.112026E+10 |
August | 0.397910E+10 | 0.190118E+10 | 0.207793E+10 | 0.459830E+10 | 0.121512E+10 |
September | 0.346773E+10 | 0.184398E+10 | 0.162375E+10 | 0.387007E+10 | 0.149553E+10 |
October | 0.172971E+10 | 0.716838E+09 | 0.101288E+10 | 0.151560E+10 | 0.201467E+10 |
November | 0.872663E+09 | 0.297416E+09 | 0.575247E+09 | 0.501028E+09 | 0.231932E+10 |
December | 0.668308E+09 | 0.248468E+09 | 0.419840E+09 | 0.338223E+09 | 0.289075E+10 |
Annual Sum or Average | 0.305739E+11 | 0.131344E+11 | 0.174396E+11 | 0.302191E+11 | 0.224676E+11 |
Minimum of Months | 0.668308E+09 | 0.248468E+09 | 0.419840E+09 | 0.338223E+09 | 0.112026E+10 |
Maximum of Months | 0.420055E+10 | 0.190118E+10 | 0.241532E+10 | 0.470824E+10 | 0.289075E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.393696E+10 | 0.254856E+10 | 0.138841E+10 | 0.388816E+10 | 0.384574E+10 |
February | 0.434296E+10 | 0.265013E+10 | 0.169283E+10 | 0.438922E+10 | 0.344250E+10 |
March | 0.297279E+10 | 0.865544E+09 | 0.210725E+10 | 0.240466E+10 | 0.318820E+10 |
April | 0.597411E+10 | 0.270023E+10 | 0.327388E+10 | 0.674988E+10 | 0.278554E+10 |
May | 0.510585E+10 | 0.166230E+10 | 0.344355E+10 | 0.530664E+10 | 0.252805E+10 |
June | 0.455185E+10 | 0.110181E+10 | 0.345004E+10 | 0.492782E+10 | 0.190413E+10 |
July | 0.509624E+10 | 0.159594E+10 | 0.350030E+10 | 0.595832E+10 | 0.182983E+10 |
August | 0.597167E+10 | 0.268628E+10 | 0.328539E+10 | 0.741213E+10 | 0.198531E+10 |
September | 0.682932E+10 | 0.400073E+10 | 0.282859E+10 | 0.839711E+10 | 0.242030E+10 |
October | 0.484842E+10 | 0.283368E+10 | 0.201474E+10 | 0.531914E+10 | 0.311042E+10 |
November | 0.332664E+10 | 0.202368E+10 | 0.130296E+10 | 0.329145E+10 | 0.349494E+10 |
December | 0.272456E+10 | 0.174564E+10 | 0.978921E+09 | 0.260841E+10 | 0.432326E+10 |
Annual Sum or Average | 0.556814E+11 | 0.264145E+11 | 0.292669E+11 | 0.606529E+11 | 0.348582E+11 |
Minimum of Months | 0.272456E+10 | 0.865544E+09 | 0.978921E+09 | 0.240466E+10 | 0.182983E+10 |
Maximum of Months | 0.682932E+10 | 0.400073E+10 | 0.350030E+10 | 0.839711E+10 | 0.432326E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_4_WALL_WEST_WINDOW
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.918904E+09 | 0.303610E+09 | 0.615294E+09 | 0.555248E+09 | 0.269825E+10 |
February | 0.146952E+10 | 0.620477E+09 | 0.849039E+09 | 0.115874E+10 | 0.235661E+10 |
March | 0.147112E+10 | 0.281426E+09 | 0.118970E+10 | 0.905302E+09 | 0.211351E+10 |
April | 0.335920E+10 | 0.133430E+10 | 0.202489E+10 | 0.342810E+10 | 0.180662E+10 |
May | 0.407248E+10 | 0.165601E+10 | 0.241647E+10 | 0.411562E+10 | 0.162610E+10 |
June | 0.425598E+10 | 0.175202E+10 | 0.250395E+10 | 0.465436E+10 | 0.125014E+10 |
July | 0.447901E+10 | 0.197481E+10 | 0.250420E+10 | 0.512242E+10 | 0.120392E+10 |
August | 0.376207E+10 | 0.162887E+10 | 0.213320E+10 | 0.434810E+10 | 0.130932E+10 |
September | 0.292082E+10 | 0.130976E+10 | 0.161106E+10 | 0.323794E+10 | 0.159858E+10 |
October | 0.161008E+10 | 0.578979E+09 | 0.103110E+10 | 0.140511E+10 | 0.207996E+10 |
November | 0.843214E+09 | 0.246145E+09 | 0.597069E+09 | 0.512853E+09 | 0.239014E+10 |
December | 0.493193E+09 | 0.104075E+09 | 0.389119E+09 | 0.179910E+09 | 0.299744E+10 |
Annual Sum or Average | 0.296556E+11 | 0.117905E+11 | 0.178651E+11 | 0.296237E+11 | 0.234306E+11 |
Minimum of Months | 0.493193E+09 | 0.104075E+09 | 0.389119E+09 | 0.179910E+09 | 0.120392E+10 |
Maximum of Months | 0.447901E+10 | 0.197481E+10 | 0.250420E+10 | 0.512242E+10 | 0.299744E+10 |
Report: WindowZoneSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 24.15 | 1483.94 | 258.91 | 0.00 | 258.91 | 0.00 | 0.00 |
February | 71.17 | 1396.30 | 404.29 | 0.00 | 404.29 | 0.00 | 0.00 |
March | 205.98 | 1150.21 | 559.47 | 0.00 | 559.47 | 0.00 | 0.00 |
April | 583.38 | 975.59 | 910.90 | 4.08 | 906.83 | 0.00 | 0.00 |
May | 734.30 | 794.42 | 1138.86 | 54.94 | 1083.92 | 0.00 | 0.00 |
June | 1038.45 | 636.73 | 1258.94 | 78.94 | 1180.00 | 0.00 | 0.00 |
July | 1054.22 | 589.06 | 1194.17 | 68.09 | 1126.09 | 0.00 | 0.00 |
August | 811.68 | 655.29 | 938.68 | 14.71 | 923.97 | 0.00 | 0.00 |
September | 536.78 | 859.86 | 714.47 | 0.16 | 714.31 | 0.00 | 0.00 |
October | 203.91 | 1084.95 | 457.82 | 0.00 | 457.82 | 0.00 | 0.00 |
November | 36.98 | 1306.77 | 275.08 | 0.00 | 275.08 | 0.00 | 0.00 |
December | 3.06 | 1592.70 | 187.33 | 0.00 | 187.33 | 0.00 | 0.00 |
Annual Sum or Average | 443.88 | 1042.01 | 692.86 | 18.53 | 674.33 | 0.00 | 0.00 |
Minimum of Months | 3.06 | 589.06 | 187.33 | 0.00 | 187.33 | 0.00 | 0.00 |
Maximum of Months | 1054.22 | 1592.70 | 1258.94 | 78.94 | 1180.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 214.57 | 930.82 | 352.80 | 141.72 | 211.08 | 0.00 | 0.00 |
February | 353.27 | 885.93 | 526.08 | 194.34 | 331.74 | 0.00 | 0.00 |
March | 350.57 | 729.99 | 549.77 | 108.34 | 441.43 | 0.00 | 0.00 |
April | 1538.59 | 624.07 | 1476.18 | 693.66 | 782.51 | 0.00 | 0.00 |
May | 1570.73 | 544.39 | 1552.15 | 676.87 | 875.29 | 0.00 | 0.00 |
June | 1652.80 | 433.59 | 1536.35 | 613.60 | 922.74 | 0.00 | 0.00 |
July | 1761.72 | 402.57 | 1568.31 | 666.53 | 901.78 | 0.00 | 0.00 |
August | 1721.08 | 435.11 | 1485.63 | 709.82 | 775.81 | 0.00 | 0.00 |
September | 1502.30 | 547.63 | 1337.86 | 711.41 | 626.45 | 0.00 | 0.00 |
October | 579.28 | 699.37 | 645.80 | 267.64 | 378.16 | 0.00 | 0.00 |
November | 202.56 | 832.28 | 336.68 | 114.74 | 221.93 | 0.00 | 0.00 |
December | 132.51 | 1013.12 | 249.52 | 92.77 | 156.75 | 0.00 | 0.00 |
Annual Sum or Average | 967.19 | 672.19 | 969.49 | 416.49 | 553.01 | 0.00 | 0.00 |
Minimum of Months | 132.51 | 402.57 | 249.52 | 92.77 | 156.75 | 0.00 | 0.00 |
Maximum of Months | 1761.72 | 1013.12 | 1568.31 | 711.41 | 922.74 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1469.75 | 1350.28 | 1469.89 | 951.52 | 518.37 | 0.00 | 0.00 |
February | 1836.50 | 1336.38 | 1795.21 | 1095.46 | 699.75 | 0.00 | 0.00 |
March | 919.11 | 1117.81 | 1109.91 | 323.16 | 786.76 | 0.00 | 0.00 |
April | 2617.78 | 1018.46 | 2304.83 | 1041.76 | 1263.07 | 0.00 | 0.00 |
May | 1996.35 | 892.28 | 1906.31 | 620.63 | 1285.68 | 0.00 | 0.00 |
June | 1910.38 | 700.29 | 1756.12 | 425.08 | 1331.03 | 0.00 | 0.00 |
July | 2231.03 | 652.67 | 1902.72 | 595.86 | 1306.86 | 0.00 | 0.00 |
August | 2773.24 | 706.09 | 2229.57 | 1002.94 | 1226.63 | 0.00 | 0.00 |
September | 3250.85 | 883.03 | 2634.77 | 1543.49 | 1091.28 | 0.00 | 0.00 |
October | 2005.51 | 1078.27 | 1810.19 | 1057.98 | 752.22 | 0.00 | 0.00 |
November | 1288.21 | 1253.21 | 1283.43 | 780.74 | 502.69 | 0.00 | 0.00 |
December | 988.64 | 1515.54 | 1017.23 | 651.75 | 365.49 | 0.00 | 0.00 |
Annual Sum or Average | 1937.89 | 1040.46 | 1765.65 | 837.60 | 928.05 | 0.00 | 0.00 |
Minimum of Months | 919.11 | 652.67 | 1017.23 | 323.16 | 365.49 | 0.00 | 0.00 |
Maximum of Months | 3250.85 | 1515.54 | 2634.77 | 1543.49 | 1331.03 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 213.49 | 947.79 | 343.08 | 113.35 | 229.72 | 0.00 | 0.00 |
February | 489.07 | 913.47 | 607.44 | 256.48 | 350.96 | 0.00 | 0.00 |
March | 349.49 | 740.82 | 549.26 | 105.07 | 444.18 | 0.00 | 0.00 |
April | 1333.64 | 659.63 | 1295.99 | 514.78 | 781.21 | 0.00 | 0.00 |
May | 1548.19 | 574.15 | 1520.49 | 618.28 | 902.21 | 0.00 | 0.00 |
June | 1801.63 | 459.81 | 1641.97 | 675.94 | 966.03 | 0.00 | 0.00 |
July | 1916.91 | 429.47 | 1672.27 | 737.31 | 934.96 | 0.00 | 0.00 |
August | 1628.81 | 465.27 | 1404.60 | 608.15 | 796.45 | 0.00 | 0.00 |
September | 1259.74 | 580.86 | 1126.86 | 505.31 | 621.55 | 0.00 | 0.00 |
October | 537.31 | 720.27 | 601.14 | 216.17 | 384.97 | 0.00 | 0.00 |
November | 204.82 | 856.79 | 325.31 | 94.96 | 230.35 | 0.00 | 0.00 |
December | 70.70 | 1050.43 | 184.14 | 38.86 | 145.28 | 0.00 | 0.00 |
Annual Sum or Average | 947.67 | 698.81 | 940.37 | 373.87 | 566.50 | 0.00 | 0.00 |
Minimum of Months | 70.70 | 429.47 | 184.14 | 38.86 | 145.28 | 0.00 | 0.00 |
Maximum of Months | 1916.91 | 1050.43 | 1672.27 | 737.31 | 966.03 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 21.80 | 1553.44 | 258.90 | 0.00 | 258.90 | 0.00 | 0.00 |
February | 67.15 | 1459.27 | 404.28 | 0.00 | 404.28 | 0.00 | 0.00 |
March | 208.09 | 1191.58 | 559.46 | 0.00 | 559.46 | 0.00 | 0.00 |
April | 609.63 | 986.91 | 910.88 | 4.08 | 906.81 | 0.00 | 0.00 |
May | 756.87 | 808.18 | 1138.84 | 54.94 | 1083.89 | 0.00 | 0.00 |
June | 1062.95 | 645.00 | 1258.91 | 78.94 | 1179.97 | 0.00 | 0.00 |
July | 1071.84 | 599.70 | 1194.15 | 68.08 | 1126.06 | 0.00 | 0.00 |
August | 826.69 | 668.71 | 938.66 | 14.71 | 923.96 | 0.00 | 0.00 |
September | 538.44 | 897.38 | 714.45 | 0.16 | 714.29 | 0.00 | 0.00 |
October | 193.19 | 1168.41 | 457.81 | 0.00 | 457.81 | 0.00 | 0.00 |
November | 30.26 | 1412.14 | 275.08 | 0.00 | 275.08 | 0.00 | 0.00 |
December | 1.06 | 1699.90 | 187.33 | 0.00 | 187.33 | 0.00 | 0.00 |
Annual Sum or Average | 450.92 | 1089.01 | 692.85 | 18.53 | 674.31 | 0.00 | 0.00 |
Minimum of Months | 1.06 | 599.70 | 187.33 | 0.00 | 187.33 | 0.00 | 0.00 |
Maximum of Months | 1071.84 | 1699.90 | 1258.91 | 78.94 | 1179.97 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 210.95 | 979.30 | 352.79 | 141.72 | 211.08 | 0.00 | 0.00 |
February | 348.67 | 931.30 | 526.08 | 194.34 | 331.74 | 0.00 | 0.00 |
March | 350.68 | 759.67 | 549.76 | 108.34 | 441.42 | 0.00 | 0.00 |
April | 1545.55 | 654.57 | 1476.15 | 693.65 | 782.50 | 0.00 | 0.00 |
May | 1575.65 | 574.24 | 1552.13 | 676.85 | 875.27 | 0.00 | 0.00 |
June | 1662.06 | 452.70 | 1536.32 | 613.59 | 922.73 | 0.00 | 0.00 |
July | 1768.96 | 423.82 | 1568.28 | 666.52 | 901.77 | 0.00 | 0.00 |
August | 1726.11 | 461.60 | 1485.60 | 709.80 | 775.80 | 0.00 | 0.00 |
September | 1499.47 | 591.66 | 1337.84 | 711.40 | 626.44 | 0.00 | 0.00 |
October | 568.86 | 764.29 | 645.79 | 267.63 | 378.16 | 0.00 | 0.00 |
November | 194.94 | 902.40 | 336.67 | 114.74 | 221.93 | 0.00 | 0.00 |
December | 127.59 | 1080.48 | 249.51 | 92.77 | 156.75 | 0.00 | 0.00 |
Annual Sum or Average | 967.17 | 713.59 | 969.48 | 416.48 | 553.00 | 0.00 | 0.00 |
Minimum of Months | 127.59 | 423.82 | 249.51 | 92.77 | 156.75 | 0.00 | 0.00 |
Maximum of Months | 1768.96 | 1080.48 | 1568.28 | 711.40 | 922.73 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1475.94 | 1421.81 | 1469.84 | 951.48 | 518.35 | 0.00 | 0.00 |
February | 1847.32 | 1412.78 | 1795.14 | 1095.41 | 699.72 | 0.00 | 0.00 |
March | 939.30 | 1151.41 | 1109.87 | 323.14 | 786.73 | 0.00 | 0.00 |
April | 2650.20 | 1058.27 | 2304.74 | 1041.71 | 1263.03 | 0.00 | 0.00 |
May | 2029.75 | 919.92 | 1906.24 | 620.61 | 1285.64 | 0.00 | 0.00 |
June | 1945.93 | 713.28 | 1756.06 | 425.06 | 1330.99 | 0.00 | 0.00 |
July | 2255.70 | 676.57 | 1902.65 | 595.83 | 1306.82 | 0.00 | 0.00 |
August | 2790.39 | 749.29 | 2229.49 | 1002.90 | 1226.59 | 0.00 | 0.00 |
September | 3256.81 | 962.05 | 2634.67 | 1543.43 | 1091.24 | 0.00 | 0.00 |
October | 2002.18 | 1183.66 | 1810.12 | 1057.93 | 752.19 | 0.00 | 0.00 |
November | 1287.97 | 1357.34 | 1283.38 | 780.71 | 502.67 | 0.00 | 0.00 |
December | 990.38 | 1599.28 | 1017.19 | 651.72 | 365.47 | 0.00 | 0.00 |
Annual Sum or Average | 1953.28 | 1098.76 | 1765.58 | 837.56 | 928.02 | 0.00 | 0.00 |
Minimum of Months | 939.30 | 676.57 | 1017.19 | 323.14 | 365.47 | 0.00 | 0.00 |
Maximum of Months | 3256.81 | 1599.28 | 2634.67 | 1543.43 | 1330.99 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 212.65 | 996.69 | 343.07 | 113.35 | 229.72 | 0.00 | 0.00 |
February | 489.02 | 962.75 | 607.43 | 256.48 | 350.95 | 0.00 | 0.00 |
March | 353.57 | 771.37 | 549.25 | 105.07 | 444.18 | 0.00 | 0.00 |
April | 1344.42 | 686.88 | 1295.97 | 514.77 | 781.20 | 0.00 | 0.00 |
May | 1556.13 | 604.85 | 1520.47 | 618.27 | 902.20 | 0.00 | 0.00 |
June | 1811.72 | 483.91 | 1641.95 | 675.92 | 966.02 | 0.00 | 0.00 |
July | 1925.85 | 453.41 | 1672.25 | 737.30 | 934.95 | 0.00 | 0.00 |
August | 1634.84 | 493.93 | 1404.58 | 608.14 | 796.44 | 0.00 | 0.00 |
September | 1256.59 | 624.57 | 1126.84 | 505.30 | 621.54 | 0.00 | 0.00 |
October | 529.30 | 783.31 | 601.13 | 216.16 | 384.97 | 0.00 | 0.00 |
November | 200.66 | 926.89 | 325.31 | 94.96 | 230.35 | 0.00 | 0.00 |
December | 68.55 | 1117.67 | 184.14 | 38.86 | 145.28 | 0.00 | 0.00 |
Annual Sum or Average | 950.14 | 741.05 | 940.36 | 373.87 | 566.49 | 0.00 | 0.00 |
Minimum of Months | 68.55 | 453.41 | 184.14 | 38.86 | 145.28 | 0.00 | 0.00 |
Maximum of Months | 1925.85 | 1117.67 | 1672.25 | 737.30 | 966.02 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 18.72 | 1579.45 | 258.91 | 0.00 | 258.91 | 0.00 | 0.00 |
February | 58.32 | 1493.39 | 404.29 | 0.00 | 404.29 | 0.00 | 0.00 |
March | 188.59 | 1227.34 | 559.47 | 0.00 | 559.47 | 0.00 | 0.00 |
April | 565.08 | 1035.43 | 910.90 | 4.08 | 906.83 | 0.00 | 0.00 |
May | 709.74 | 841.20 | 1138.86 | 54.94 | 1083.92 | 0.00 | 0.00 |
June | 1025.93 | 666.41 | 1258.94 | 78.94 | 1180.00 | 0.00 | 0.00 |
July | 1043.30 | 615.10 | 1194.17 | 68.09 | 1126.09 | 0.00 | 0.00 |
August | 801.54 | 688.50 | 938.68 | 14.71 | 923.97 | 0.00 | 0.00 |
September | 520.14 | 915.65 | 714.47 | 0.16 | 714.31 | 0.00 | 0.00 |
October | 183.72 | 1177.17 | 457.82 | 0.00 | 457.82 | 0.00 | 0.00 |
November | 28.54 | 1412.26 | 275.08 | 0.00 | 275.08 | 0.00 | 0.00 |
December | 1.03 | 1700.79 | 187.33 | 0.00 | 187.33 | 0.00 | 0.00 |
Annual Sum or Average | 430.60 | 1110.75 | 692.86 | 18.53 | 674.33 | 0.00 | 0.00 |
Minimum of Months | 1.03 | 615.10 | 187.33 | 0.00 | 187.33 | 0.00 | 0.00 |
Maximum of Months | 1043.30 | 1700.79 | 1258.94 | 78.94 | 1180.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 206.59 | 988.73 | 352.80 | 141.72 | 211.08 | 0.00 | 0.00 |
February | 340.30 | 943.95 | 526.08 | 194.34 | 331.74 | 0.00 | 0.00 |
March | 337.64 | 775.87 | 549.77 | 108.34 | 441.43 | 0.00 | 0.00 |
April | 1527.79 | 655.95 | 1476.18 | 693.66 | 782.51 | 0.00 | 0.00 |
May | 1559.51 | 571.65 | 1552.15 | 676.87 | 875.29 | 0.00 | 0.00 |
June | 1647.28 | 451.63 | 1536.35 | 613.60 | 922.74 | 0.00 | 0.00 |
July | 1757.85 | 418.26 | 1568.31 | 666.53 | 901.78 | 0.00 | 0.00 |
August | 1716.81 | 453.67 | 1485.63 | 709.82 | 775.81 | 0.00 | 0.00 |
September | 1493.08 | 576.98 | 1337.86 | 711.41 | 626.45 | 0.00 | 0.00 |
October | 565.86 | 752.19 | 645.80 | 267.64 | 378.16 | 0.00 | 0.00 |
November | 193.30 | 894.80 | 336.68 | 114.74 | 221.93 | 0.00 | 0.00 |
December | 126.28 | 1079.28 | 249.52 | 92.77 | 156.75 | 0.00 | 0.00 |
Annual Sum or Average | 958.24 | 712.44 | 969.49 | 416.49 | 553.01 | 0.00 | 0.00 |
Minimum of Months | 126.28 | 418.26 | 249.52 | 92.77 | 156.75 | 0.00 | 0.00 |
Maximum of Months | 1757.85 | 1079.28 | 1568.31 | 711.41 | 922.74 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1451.67 | 1435.84 | 1469.89 | 951.52 | 518.37 | 0.00 | 0.00 |
February | 1814.33 | 1422.99 | 1795.21 | 1095.46 | 699.75 | 0.00 | 0.00 |
March | 897.80 | 1190.34 | 1109.91 | 323.16 | 786.76 | 0.00 | 0.00 |
April | 2604.12 | 1074.67 | 2304.83 | 1041.76 | 1263.07 | 0.00 | 0.00 |
May | 1981.27 | 943.86 | 1906.31 | 620.63 | 1285.68 | 0.00 | 0.00 |
June | 1901.16 | 734.62 | 1756.12 | 425.08 | 1331.03 | 0.00 | 0.00 |
July | 2224.58 | 683.18 | 1902.72 | 595.86 | 1306.86 | 0.00 | 0.00 |
August | 2767.37 | 741.23 | 2229.57 | 1002.94 | 1226.63 | 0.00 | 0.00 |
September | 3239.63 | 933.76 | 2634.77 | 1543.49 | 1091.28 | 0.00 | 0.00 |
October | 1985.94 | 1161.30 | 1810.19 | 1057.98 | 752.22 | 0.00 | 0.00 |
November | 1269.85 | 1348.36 | 1283.43 | 780.74 | 502.69 | 0.00 | 0.00 |
December | 973.87 | 1614.12 | 1017.23 | 651.75 | 365.49 | 0.00 | 0.00 |
Annual Sum or Average | 1923.29 | 1105.35 | 1765.65 | 837.60 | 928.05 | 0.00 | 0.00 |
Minimum of Months | 897.80 | 683.18 | 1017.23 | 323.16 | 365.49 | 0.00 | 0.00 |
Maximum of Months | 3239.63 | 1614.12 | 2634.77 | 1543.49 | 1331.03 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 207.31 | 1007.41 | 343.08 | 113.35 | 229.72 | 0.00 | 0.00 |
February | 478.98 | 974.13 | 607.44 | 256.48 | 350.96 | 0.00 | 0.00 |
March | 338.00 | 789.10 | 549.26 | 105.07 | 444.18 | 0.00 | 0.00 |
April | 1322.57 | 697.00 | 1295.99 | 514.78 | 781.21 | 0.00 | 0.00 |
May | 1536.60 | 607.12 | 1520.49 | 618.28 | 902.21 | 0.00 | 0.00 |
June | 1795.66 | 482.31 | 1641.97 | 675.94 | 966.03 | 0.00 | 0.00 |
July | 1912.49 | 449.49 | 1672.27 | 737.31 | 934.96 | 0.00 | 0.00 |
August | 1623.40 | 488.84 | 1404.60 | 608.15 | 796.45 | 0.00 | 0.00 |
September | 1249.20 | 616.74 | 1126.86 | 505.31 | 621.55 | 0.00 | 0.00 |
October | 524.61 | 776.57 | 601.14 | 216.17 | 384.97 | 0.00 | 0.00 |
November | 197.86 | 922.12 | 325.31 | 94.96 | 230.35 | 0.00 | 0.00 |
December | 67.17 | 1119.12 | 184.14 | 38.86 | 145.28 | 0.00 | 0.00 |
Annual Sum or Average | 939.36 | 742.98 | 940.37 | 373.87 | 566.50 | 0.00 | 0.00 |
Minimum of Months | 67.17 | 449.49 | 184.14 | 38.86 | 145.28 | 0.00 | 0.00 |
Maximum of Months | 1912.49 | 1119.12 | 1672.27 | 737.31 | 966.03 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 64693257.22 | 0.397457E+10 | 0.693455E+09 | 0.00 | 0.693455E+09 | 0.00 | 0.00 |
February | 0.172167E+09 | 0.337792E+10 | 0.978065E+09 | 0.00 | 0.978065E+09 | 0.00 | 0.00 |
March | 0.551687E+09 | 0.308073E+10 | 0.149848E+10 | 0.00 | 0.149848E+10 | 0.00 | 0.00 |
April | 0.151212E+10 | 0.252873E+10 | 0.236106E+10 | 10567121.51 | 0.235049E+10 | 0.00 | 0.00 |
May | 0.196675E+10 | 0.212779E+10 | 0.305033E+10 | 0.147164E+09 | 0.290316E+10 | 0.00 | 0.00 |
June | 0.269166E+10 | 0.165039E+10 | 0.326317E+10 | 0.204622E+09 | 0.305855E+10 | 0.00 | 0.00 |
July | 0.282362E+10 | 0.157773E+10 | 0.319847E+10 | 0.182362E+09 | 0.301611E+10 | 0.00 | 0.00 |
August | 0.217400E+10 | 0.175513E+10 | 0.251416E+10 | 39390701.15 | 0.247477E+10 | 0.00 | 0.00 |
September | 0.139133E+10 | 0.222876E+10 | 0.185189E+10 | 409786.82 | 0.185148E+10 | 0.00 | 0.00 |
October | 0.546158E+09 | 0.290592E+10 | 0.122624E+10 | 0.00 | 0.122624E+10 | 0.00 | 0.00 |
November | 95847264.98 | 0.338716E+10 | 0.713019E+09 | 0.00 | 0.713019E+09 | 0.00 | 0.00 |
December | 8192083.51 | 0.426589E+10 | 0.501749E+09 | 0.00 | 0.501749E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.139982E+11 | 0.328607E+11 | 0.218501E+11 | 0.584515E+09 | 0.212656E+11 | 0.00 | 0.00 |
Minimum of Months | 8192083.51 | 0.157773E+10 | 0.501749E+09 | 0.00 | 0.501749E+09 | 0.00 | 0.00 |
Maximum of Months | 0.282362E+10 | 0.426589E+10 | 0.326317E+10 | 0.204622E+09 | 0.305855E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.574715E+09 | 0.249311E+10 | 0.944935E+09 | 0.379582E+09 | 0.565353E+09 | 0.00 | 0.00 |
February | 0.854636E+09 | 0.214325E+10 | 0.127270E+10 | 0.470146E+09 | 0.802556E+09 | 0.00 | 0.00 |
March | 0.938978E+09 | 0.195520E+10 | 0.147250E+10 | 0.290176E+09 | 0.118233E+10 | 0.00 | 0.00 |
April | 0.398802E+10 | 0.161758E+10 | 0.382625E+10 | 0.179798E+10 | 0.202827E+10 | 0.00 | 0.00 |
May | 0.420704E+10 | 0.145810E+10 | 0.415728E+10 | 0.181292E+10 | 0.234436E+10 | 0.00 | 0.00 |
June | 0.428407E+10 | 0.112386E+10 | 0.398221E+10 | 0.159046E+10 | 0.239175E+10 | 0.00 | 0.00 |
July | 0.471858E+10 | 0.107824E+10 | 0.420055E+10 | 0.178523E+10 | 0.241532E+10 | 0.00 | 0.00 |
August | 0.460973E+10 | 0.116539E+10 | 0.397910E+10 | 0.190118E+10 | 0.207793E+10 | 0.00 | 0.00 |
September | 0.389396E+10 | 0.141946E+10 | 0.346773E+10 | 0.184398E+10 | 0.162375E+10 | 0.00 | 0.00 |
October | 0.155153E+10 | 0.187320E+10 | 0.172971E+10 | 0.716838E+09 | 0.101288E+10 | 0.00 | 0.00 |
November | 0.525048E+09 | 0.215726E+10 | 0.872663E+09 | 0.297416E+09 | 0.575247E+09 | 0.00 | 0.00 |
December | 0.354920E+09 | 0.271355E+10 | 0.668308E+09 | 0.248468E+09 | 0.419840E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.305012E+11 | 0.211982E+11 | 0.305739E+11 | 0.131344E+11 | 0.174396E+11 | 0.00 | 0.00 |
Minimum of Months | 0.354920E+09 | 0.107824E+10 | 0.668308E+09 | 0.248468E+09 | 0.419840E+09 | 0.00 | 0.00 |
Maximum of Months | 0.471858E+10 | 0.271355E+10 | 0.420055E+10 | 0.190118E+10 | 0.241532E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.393657E+10 | 0.361659E+10 | 0.393696E+10 | 0.254856E+10 | 0.138841E+10 | 0.00 | 0.00 |
February | 0.444287E+10 | 0.323297E+10 | 0.434296E+10 | 0.265013E+10 | 0.169283E+10 | 0.00 | 0.00 |
March | 0.246173E+10 | 0.299395E+10 | 0.297279E+10 | 0.865544E+09 | 0.210725E+10 | 0.00 | 0.00 |
April | 0.678528E+10 | 0.263985E+10 | 0.597411E+10 | 0.270023E+10 | 0.327388E+10 | 0.00 | 0.00 |
May | 0.534703E+10 | 0.238988E+10 | 0.510585E+10 | 0.166230E+10 | 0.344355E+10 | 0.00 | 0.00 |
June | 0.495170E+10 | 0.181516E+10 | 0.455185E+10 | 0.110181E+10 | 0.345004E+10 | 0.00 | 0.00 |
July | 0.597560E+10 | 0.174812E+10 | 0.509624E+10 | 0.159594E+10 | 0.350030E+10 | 0.00 | 0.00 |
August | 0.742786E+10 | 0.189119E+10 | 0.597167E+10 | 0.268628E+10 | 0.328539E+10 | 0.00 | 0.00 |
September | 0.842619E+10 | 0.228883E+10 | 0.682932E+10 | 0.400073E+10 | 0.282859E+10 | 0.00 | 0.00 |
October | 0.537155E+10 | 0.288804E+10 | 0.484842E+10 | 0.283368E+10 | 0.201474E+10 | 0.00 | 0.00 |
November | 0.333903E+10 | 0.324832E+10 | 0.332664E+10 | 0.202368E+10 | 0.130296E+10 | 0.00 | 0.00 |
December | 0.264797E+10 | 0.405921E+10 | 0.272456E+10 | 0.174564E+10 | 0.978921E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.611134E+11 | 0.328121E+11 | 0.556814E+11 | 0.264145E+11 | 0.292669E+11 | 0.00 | 0.00 |
Minimum of Months | 0.246173E+10 | 0.174812E+10 | 0.272456E+10 | 0.865544E+09 | 0.978921E+09 | 0.00 | 0.00 |
Maximum of Months | 0.842619E+10 | 0.405921E+10 | 0.682932E+10 | 0.400073E+10 | 0.350030E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.571799E+09 | 0.253855E+10 | 0.918904E+09 | 0.303610E+09 | 0.615294E+09 | 0.00 | 0.00 |
February | 0.118316E+10 | 0.220988E+10 | 0.146952E+10 | 0.620477E+09 | 0.849039E+09 | 0.00 | 0.00 |
March | 0.936066E+09 | 0.198422E+10 | 0.147112E+10 | 0.281426E+09 | 0.118970E+10 | 0.00 | 0.00 |
April | 0.345680E+10 | 0.170975E+10 | 0.335920E+10 | 0.133430E+10 | 0.202489E+10 | 0.00 | 0.00 |
May | 0.414669E+10 | 0.153781E+10 | 0.407248E+10 | 0.165601E+10 | 0.241647E+10 | 0.00 | 0.00 |
June | 0.466981E+10 | 0.119183E+10 | 0.425598E+10 | 0.175202E+10 | 0.250395E+10 | 0.00 | 0.00 |
July | 0.513424E+10 | 0.115028E+10 | 0.447901E+10 | 0.197481E+10 | 0.250420E+10 | 0.00 | 0.00 |
August | 0.436261E+10 | 0.124617E+10 | 0.376207E+10 | 0.162887E+10 | 0.213320E+10 | 0.00 | 0.00 |
September | 0.326524E+10 | 0.150559E+10 | 0.292082E+10 | 0.130976E+10 | 0.161106E+10 | 0.00 | 0.00 |
October | 0.143914E+10 | 0.192917E+10 | 0.161008E+10 | 0.578979E+09 | 0.103110E+10 | 0.00 | 0.00 |
November | 0.530884E+09 | 0.222081E+10 | 0.843214E+09 | 0.246145E+09 | 0.597069E+09 | 0.00 | 0.00 |
December | 0.189375E+09 | 0.281346E+10 | 0.493193E+09 | 0.104075E+09 | 0.389119E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.298858E+11 | 0.220375E+11 | 0.296556E+11 | 0.117905E+11 | 0.178651E+11 | 0.00 | 0.00 |
Minimum of Months | 0.189375E+09 | 0.115028E+10 | 0.493193E+09 | 0.104075E+09 | 0.389119E+09 | 0.00 | 0.00 |
Maximum of Months | 0.513424E+10 | 0.281346E+10 | 0.447901E+10 | 0.197481E+10 | 0.250420E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 58396269.44 | 0.416073E+10 | 0.693439E+09 | 0.00 | 0.693439E+09 | 0.00 | 0.00 |
February | 0.162461E+09 | 0.353027E+10 | 0.978043E+09 | 0.00 | 0.978043E+09 | 0.00 | 0.00 |
March | 0.557360E+09 | 0.319153E+10 | 0.149845E+10 | 0.00 | 0.149845E+10 | 0.00 | 0.00 |
April | 0.158016E+10 | 0.255807E+10 | 0.236101E+10 | 10566810.92 | 0.235044E+10 | 0.00 | 0.00 |
May | 0.202720E+10 | 0.216463E+10 | 0.305026E+10 | 0.147159E+09 | 0.290310E+10 | 0.00 | 0.00 |
June | 0.275517E+10 | 0.167183E+10 | 0.326310E+10 | 0.204616E+09 | 0.305848E+10 | 0.00 | 0.00 |
July | 0.287081E+10 | 0.160624E+10 | 0.319840E+10 | 0.182356E+09 | 0.301605E+10 | 0.00 | 0.00 |
August | 0.221422E+10 | 0.179106E+10 | 0.251411E+10 | 39389543.35 | 0.247472E+10 | 0.00 | 0.00 |
September | 0.139564E+10 | 0.232602E+10 | 0.185186E+10 | 409774.77 | 0.185145E+10 | 0.00 | 0.00 |
October | 0.517446E+09 | 0.312947E+10 | 0.122621E+10 | 0.00 | 0.122621E+10 | 0.00 | 0.00 |
November | 78436877.81 | 0.366028E+10 | 0.713002E+09 | 0.00 | 0.713002E+09 | 0.00 | 0.00 |
December | 2849301.23 | 0.455302E+10 | 0.501738E+09 | 0.00 | 0.501738E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.142201E+11 | 0.343431E+11 | 0.218496E+11 | 0.584498E+09 | 0.212651E+11 | 0.00 | 0.00 |
Minimum of Months | 2849301.23 | 0.160624E+10 | 0.501738E+09 | 0.00 | 0.501738E+09 | 0.00 | 0.00 |
Maximum of Months | 0.287081E+10 | 0.455302E+10 | 0.326310E+10 | 0.204616E+09 | 0.305848E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.565015E+09 | 0.262295E+10 | 0.944920E+09 | 0.379575E+09 | 0.565345E+09 | 0.00 | 0.00 |
February | 0.843494E+09 | 0.225301E+10 | 0.127268E+10 | 0.470136E+09 | 0.802545E+09 | 0.00 | 0.00 |
March | 0.939267E+09 | 0.203469E+10 | 0.147248E+10 | 0.290171E+09 | 0.118231E+10 | 0.00 | 0.00 |
April | 0.400608E+10 | 0.169664E+10 | 0.382618E+10 | 0.179794E+10 | 0.202824E+10 | 0.00 | 0.00 |
May | 0.422022E+10 | 0.153806E+10 | 0.415722E+10 | 0.181288E+10 | 0.234433E+10 | 0.00 | 0.00 |
June | 0.430805E+10 | 0.117339E+10 | 0.398215E+10 | 0.159042E+10 | 0.239172E+10 | 0.00 | 0.00 |
July | 0.473798E+10 | 0.113515E+10 | 0.420049E+10 | 0.178520E+10 | 0.241529E+10 | 0.00 | 0.00 |
August | 0.462321E+10 | 0.123635E+10 | 0.397904E+10 | 0.190114E+10 | 0.207790E+10 | 0.00 | 0.00 |
September | 0.388664E+10 | 0.153359E+10 | 0.346767E+10 | 0.184394E+10 | 0.162373E+10 | 0.00 | 0.00 |
October | 0.152365E+10 | 0.204707E+10 | 0.172969E+10 | 0.716824E+09 | 0.101286E+10 | 0.00 | 0.00 |
November | 0.505288E+09 | 0.233903E+10 | 0.872649E+09 | 0.297410E+09 | 0.575239E+09 | 0.00 | 0.00 |
December | 0.341742E+09 | 0.289395E+10 | 0.668297E+09 | 0.248463E+09 | 0.419834E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.305006E+11 | 0.225039E+11 | 0.305735E+11 | 0.131341E+11 | 0.174394E+11 | 0.00 | 0.00 |
Minimum of Months | 0.341742E+09 | 0.113515E+10 | 0.668297E+09 | 0.248463E+09 | 0.419834E+09 | 0.00 | 0.00 |
Maximum of Months | 0.473798E+10 | 0.289395E+10 | 0.420049E+10 | 0.190114E+10 | 0.241529E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.395316E+10 | 0.380817E+10 | 0.393681E+10 | 0.254845E+10 | 0.138835E+10 | 0.00 | 0.00 |
February | 0.446905E+10 | 0.341780E+10 | 0.434279E+10 | 0.265002E+10 | 0.169277E+10 | 0.00 | 0.00 |
March | 0.251583E+10 | 0.308393E+10 | 0.297268E+10 | 0.865508E+09 | 0.210718E+10 | 0.00 | 0.00 |
April | 0.686931E+10 | 0.274303E+10 | 0.597390E+10 | 0.270012E+10 | 0.327378E+10 | 0.00 | 0.00 |
May | 0.543647E+10 | 0.246391E+10 | 0.510568E+10 | 0.166223E+10 | 0.344345E+10 | 0.00 | 0.00 |
June | 0.504385E+10 | 0.184881E+10 | 0.455170E+10 | 0.110177E+10 | 0.344993E+10 | 0.00 | 0.00 |
July | 0.604166E+10 | 0.181211E+10 | 0.509607E+10 | 0.159588E+10 | 0.350019E+10 | 0.00 | 0.00 |
August | 0.747379E+10 | 0.200691E+10 | 0.597146E+10 | 0.268617E+10 | 0.328529E+10 | 0.00 | 0.00 |
September | 0.844166E+10 | 0.249363E+10 | 0.682906E+10 | 0.400056E+10 | 0.282850E+10 | 0.00 | 0.00 |
October | 0.536264E+10 | 0.317032E+10 | 0.484824E+10 | 0.283357E+10 | 0.201467E+10 | 0.00 | 0.00 |
November | 0.333843E+10 | 0.351823E+10 | 0.332651E+10 | 0.202360E+10 | 0.130291E+10 | 0.00 | 0.00 |
December | 0.265265E+10 | 0.428352E+10 | 0.272445E+10 | 0.174557E+10 | 0.978885E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.615985E+11 | 0.346504E+11 | 0.556793E+11 | 0.264134E+11 | 0.292659E+11 | 0.00 | 0.00 |
Minimum of Months | 0.251583E+10 | 0.181211E+10 | 0.272445E+10 | 0.865508E+09 | 0.978885E+09 | 0.00 | 0.00 |
Maximum of Months | 0.844166E+10 | 0.428352E+10 | 0.682906E+10 | 0.400056E+10 | 0.350019E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.569555E+09 | 0.266954E+10 | 0.918891E+09 | 0.303605E+09 | 0.615287E+09 | 0.00 | 0.00 |
February | 0.118303E+10 | 0.232908E+10 | 0.146950E+10 | 0.620467E+09 | 0.849029E+09 | 0.00 | 0.00 |
March | 0.947005E+09 | 0.206604E+10 | 0.147111E+10 | 0.281422E+09 | 0.118968E+10 | 0.00 | 0.00 |
April | 0.348474E+10 | 0.178038E+10 | 0.335915E+10 | 0.133428E+10 | 0.202487E+10 | 0.00 | 0.00 |
May | 0.416793E+10 | 0.162003E+10 | 0.407243E+10 | 0.165599E+10 | 0.241645E+10 | 0.00 | 0.00 |
June | 0.469597E+10 | 0.125428E+10 | 0.425592E+10 | 0.175200E+10 | 0.250393E+10 | 0.00 | 0.00 |
July | 0.515820E+10 | 0.121441E+10 | 0.447895E+10 | 0.197478E+10 | 0.250418E+10 | 0.00 | 0.00 |
August | 0.437875E+10 | 0.132293E+10 | 0.376202E+10 | 0.162885E+10 | 0.213318E+10 | 0.00 | 0.00 |
September | 0.325709E+10 | 0.161890E+10 | 0.292078E+10 | 0.130974E+10 | 0.161104E+10 | 0.00 | 0.00 |
October | 0.141767E+10 | 0.209803E+10 | 0.161006E+10 | 0.578969E+09 | 0.103109E+10 | 0.00 | 0.00 |
November | 0.520115E+09 | 0.240250E+10 | 0.843203E+09 | 0.246141E+09 | 0.597062E+09 | 0.00 | 0.00 |
December | 0.183603E+09 | 0.299357E+10 | 0.493187E+09 | 0.104073E+09 | 0.389114E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.299637E+11 | 0.233697E+11 | 0.296552E+11 | 0.117903E+11 | 0.178649E+11 | 0.00 | 0.00 |
Minimum of Months | 0.183603E+09 | 0.121441E+10 | 0.493187E+09 | 0.104073E+09 | 0.389114E+09 | 0.00 | 0.00 |
Maximum of Months | 0.515820E+10 | 0.299357E+10 | 0.447895E+10 | 0.197478E+10 | 0.250418E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 50144748.88 | 0.423039E+10 | 0.693455E+09 | 0.00 | 0.693455E+09 | 0.00 | 0.00 |
February | 0.141086E+09 | 0.361282E+10 | 0.978065E+09 | 0.00 | 0.978065E+09 | 0.00 | 0.00 |
March | 0.505108E+09 | 0.328729E+10 | 0.149848E+10 | 0.00 | 0.149848E+10 | 0.00 | 0.00 |
April | 0.146470E+10 | 0.268384E+10 | 0.236106E+10 | 10567121.51 | 0.235049E+10 | 0.00 | 0.00 |
May | 0.190096E+10 | 0.225308E+10 | 0.305033E+10 | 0.147164E+09 | 0.290316E+10 | 0.00 | 0.00 |
June | 0.265922E+10 | 0.172732E+10 | 0.326317E+10 | 0.204622E+09 | 0.305855E+10 | 0.00 | 0.00 |
July | 0.279437E+10 | 0.164748E+10 | 0.319847E+10 | 0.182362E+09 | 0.301611E+10 | 0.00 | 0.00 |
August | 0.214684E+10 | 0.184408E+10 | 0.251416E+10 | 39390701.15 | 0.247477E+10 | 0.00 | 0.00 |
September | 0.134821E+10 | 0.237336E+10 | 0.185189E+10 | 409786.82 | 0.185148E+10 | 0.00 | 0.00 |
October | 0.492076E+09 | 0.315293E+10 | 0.122624E+10 | 0.00 | 0.122624E+10 | 0.00 | 0.00 |
November | 73981112.28 | 0.366057E+10 | 0.713019E+09 | 0.00 | 0.713019E+09 | 0.00 | 0.00 |
December | 2746541.31 | 0.455540E+10 | 0.501749E+09 | 0.00 | 0.501749E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.135794E+11 | 0.350286E+11 | 0.218501E+11 | 0.584515E+09 | 0.212656E+11 | 0.00 | 0.00 |
Minimum of Months | 2746541.31 | 0.164748E+10 | 0.501749E+09 | 0.00 | 0.501749E+09 | 0.00 | 0.00 |
Maximum of Months | 0.279437E+10 | 0.455540E+10 | 0.326317E+10 | 0.204622E+09 | 0.305855E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.553330E+09 | 0.264823E+10 | 0.944935E+09 | 0.379582E+09 | 0.565353E+09 | 0.00 | 0.00 |
February | 0.823261E+09 | 0.228361E+10 | 0.127270E+10 | 0.470146E+09 | 0.802556E+09 | 0.00 | 0.00 |
March | 0.904336E+09 | 0.207810E+10 | 0.147250E+10 | 0.290176E+09 | 0.118233E+10 | 0.00 | 0.00 |
April | 0.396004E+10 | 0.170023E+10 | 0.382625E+10 | 0.179798E+10 | 0.202827E+10 | 0.00 | 0.00 |
May | 0.417699E+10 | 0.153112E+10 | 0.415728E+10 | 0.181292E+10 | 0.234436E+10 | 0.00 | 0.00 |
June | 0.426974E+10 | 0.117064E+10 | 0.398221E+10 | 0.159046E+10 | 0.239175E+10 | 0.00 | 0.00 |
July | 0.470824E+10 | 0.112026E+10 | 0.420055E+10 | 0.178523E+10 | 0.241532E+10 | 0.00 | 0.00 |
August | 0.459830E+10 | 0.121512E+10 | 0.397910E+10 | 0.190118E+10 | 0.207793E+10 | 0.00 | 0.00 |
September | 0.387007E+10 | 0.149553E+10 | 0.346773E+10 | 0.184398E+10 | 0.162375E+10 | 0.00 | 0.00 |
October | 0.151560E+10 | 0.201467E+10 | 0.172971E+10 | 0.716838E+09 | 0.101288E+10 | 0.00 | 0.00 |
November | 0.501028E+09 | 0.231932E+10 | 0.872663E+09 | 0.297416E+09 | 0.575247E+09 | 0.00 | 0.00 |
December | 0.338223E+09 | 0.289075E+10 | 0.668308E+09 | 0.248468E+09 | 0.419840E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.302191E+11 | 0.224676E+11 | 0.305739E+11 | 0.131344E+11 | 0.174396E+11 | 0.00 | 0.00 |
Minimum of Months | 0.338223E+09 | 0.112026E+10 | 0.668308E+09 | 0.248468E+09 | 0.419840E+09 | 0.00 | 0.00 |
Maximum of Months | 0.470824E+10 | 0.289075E+10 | 0.420055E+10 | 0.190118E+10 | 0.241532E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.388816E+10 | 0.384574E+10 | 0.393696E+10 | 0.254856E+10 | 0.138841E+10 | 0.00 | 0.00 |
February | 0.438922E+10 | 0.344250E+10 | 0.434296E+10 | 0.265013E+10 | 0.169283E+10 | 0.00 | 0.00 |
March | 0.240466E+10 | 0.318820E+10 | 0.297279E+10 | 0.865544E+09 | 0.210725E+10 | 0.00 | 0.00 |
April | 0.674988E+10 | 0.278554E+10 | 0.597411E+10 | 0.270023E+10 | 0.327388E+10 | 0.00 | 0.00 |
May | 0.530664E+10 | 0.252805E+10 | 0.510585E+10 | 0.166230E+10 | 0.344355E+10 | 0.00 | 0.00 |
June | 0.492782E+10 | 0.190413E+10 | 0.455185E+10 | 0.110181E+10 | 0.345004E+10 | 0.00 | 0.00 |
July | 0.595832E+10 | 0.182983E+10 | 0.509624E+10 | 0.159594E+10 | 0.350030E+10 | 0.00 | 0.00 |
August | 0.741213E+10 | 0.198531E+10 | 0.597167E+10 | 0.268628E+10 | 0.328539E+10 | 0.00 | 0.00 |
September | 0.839711E+10 | 0.242030E+10 | 0.682932E+10 | 0.400073E+10 | 0.282859E+10 | 0.00 | 0.00 |
October | 0.531914E+10 | 0.311042E+10 | 0.484842E+10 | 0.283368E+10 | 0.201474E+10 | 0.00 | 0.00 |
November | 0.329145E+10 | 0.349494E+10 | 0.332664E+10 | 0.202368E+10 | 0.130296E+10 | 0.00 | 0.00 |
December | 0.260841E+10 | 0.432326E+10 | 0.272456E+10 | 0.174564E+10 | 0.978921E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.606529E+11 | 0.348582E+11 | 0.556814E+11 | 0.264145E+11 | 0.292669E+11 | 0.00 | 0.00 |
Minimum of Months | 0.240466E+10 | 0.182983E+10 | 0.272456E+10 | 0.865544E+09 | 0.978921E+09 | 0.00 | 0.00 |
Maximum of Months | 0.839711E+10 | 0.432326E+10 | 0.682932E+10 | 0.400073E+10 | 0.350030E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.555248E+09 | 0.269825E+10 | 0.918904E+09 | 0.303610E+09 | 0.615294E+09 | 0.00 | 0.00 |
February | 0.115874E+10 | 0.235661E+10 | 0.146952E+10 | 0.620477E+09 | 0.849039E+09 | 0.00 | 0.00 |
March | 0.905302E+09 | 0.211351E+10 | 0.147112E+10 | 0.281426E+09 | 0.118970E+10 | 0.00 | 0.00 |
April | 0.342810E+10 | 0.180662E+10 | 0.335920E+10 | 0.133430E+10 | 0.202489E+10 | 0.00 | 0.00 |
May | 0.411562E+10 | 0.162610E+10 | 0.407248E+10 | 0.165601E+10 | 0.241647E+10 | 0.00 | 0.00 |
June | 0.465436E+10 | 0.125014E+10 | 0.425598E+10 | 0.175202E+10 | 0.250395E+10 | 0.00 | 0.00 |
July | 0.512242E+10 | 0.120392E+10 | 0.447901E+10 | 0.197481E+10 | 0.250420E+10 | 0.00 | 0.00 |
August | 0.434810E+10 | 0.130932E+10 | 0.376207E+10 | 0.162887E+10 | 0.213320E+10 | 0.00 | 0.00 |
September | 0.323794E+10 | 0.159858E+10 | 0.292082E+10 | 0.130976E+10 | 0.161106E+10 | 0.00 | 0.00 |
October | 0.140511E+10 | 0.207996E+10 | 0.161008E+10 | 0.578979E+09 | 0.103110E+10 | 0.00 | 0.00 |
November | 0.512853E+09 | 0.239014E+10 | 0.843214E+09 | 0.246145E+09 | 0.597069E+09 | 0.00 | 0.00 |
December | 0.179910E+09 | 0.299744E+10 | 0.493193E+09 | 0.104075E+09 | 0.389119E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.296237E+11 | 0.234306E+11 | 0.296556E+11 | 0.117905E+11 | 0.178651E+11 | 0.00 | 0.00 |
Minimum of Months | 0.179910E+09 | 0.120392E+10 | 0.493193E+09 | 0.104075E+09 | 0.389119E+09 | 0.00 | 0.00 |
Maximum of Months | 0.512242E+10 | 0.299744E+10 | 0.447901E+10 | 0.197481E+10 | 0.250420E+10 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 4.18 | 3.23 | 2.03 | 1.05 | -4.0 | 28.28 | 62.93 | 0.00 |
February | 4.25 | 3.55 | 2.74 | 1.60 | -5.0 | 43.80 | 86.73 | 0.02 |
March | 5.90 | 4.45 | 2.76 | 1.18 | -1.9 | 68.95 | 35.00 | 0.00 |
April | 8.96 | 6.24 | 3.38 | 1.56 | -0.7 | 96.13 | 186.12 | 0.00 |
May | 9.99 | 8.07 | 6.28 | 3.35 | -0.9 | 110.92 | 199.68 | 0.02 |
June | 13.31 | 11.27 | 9.70 | 3.33 | 3.35 | 121.69 | 199.28 | 0.00 |
July | 15.02 | 12.39 | 10.49 | 3.21 | 4.49 | 111.91 | 220.83 | 0.00 |
August | 15.65 | 12.75 | 10.65 | 2.92 | 3.95 | 91.47 | 211.91 | 0.00 |
September | 13.43 | 11.01 | 9.10 | 2.64 | 1.43 | 68.72 | 198.32 | 0.01 |
October | 9.33 | 8.03 | 6.81 | 1.97 | -1.0 | 48.92 | 91.86 | 0.04 |
November | 6.66 | 5.66 | 4.54 | 2.05 | -2.3 | 30.27 | 53.24 | 0.04 |
December | 4.10 | 3.14 | 1.95 | 2.36 | -5.1 | 20.52 | 40.74 | 0.04 |
Annual Sum or Average | 9.26 | 7.50 | 5.89 | 2.27 | -0.6 | 70.25 | 132.30 | 0.02 |
Minimum of Months | 4.10 | 3.14 | 1.95 | 1.05 | -5.1 | 20.52 | 35.00 | 0.00 |
Maximum of Months | 15.65 | 12.75 | 10.65 | 3.35 | 4.49 | 121.69 | 220.83 | 0.04 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 14.00 | 29-JAN-05:00 | 9.37 | 5.00 | 3.60 | 8.35 | 0.00 | 0.00 |
February | 11.00 | 07-FEB-14:00 | 9.86 | 9.00 | 2.10 | 6.35 | 138.00 | 225.00 |
March | 14.00 | 25-MAR-12:00 | 11.22 | 9.00 | 2.60 | 7.35 | 287.00 | 93.00 |
April | 24.00 | 30-APR-14:00 | 13.13 | 4.00 | 1.50 | 7.75 | 167.50 | 716.00 |
May | 24.00 | 22-MAY-14:00 | 16.08 | 11.00 | 2.60 | 9.33 | 159.00 | 769.00 |
June | 27.00 | 13-JUN-16:00 | 17.53 | 12.00 | 3.10 | 12.41 | 141.50 | 652.50 |
July | 30.00 | 22-JUL-17:00 | 16.80 | 8.00 | 0.00 | 14.28 | 122.00 | 407.00 |
August | 27.00 | 14-AUG-17:19 | 14.18 | 3.33 | 2.60 | 10.37 | 133.00 | 358.83 |
September | 23.00 | 11-SEP-16:00 | 16.22 | 12.00 | 2.60 | 8.74 | 108.00 | 325.50 |
October | 19.00 | 07-OCT-14:00 | 10.10 | 1.00 | 1.50 | 2.22 | 131.00 | 540.50 |
November | 16.00 | 24-NOV-11:00 | 12.01 | 9.00 | 4.10 | 9.33 | 61.50 | 0.00 |
December | 13.00 | 23-DEC-10:00 | 7.64 | 2.00 | 7.70 | 6.75 | 70.50 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 11.00 | 7.64 | 1.00 | 0.00 | 2.22 | 0.00 | 0.00 | |
Maximum of Months | 30.00 | 17.53 | 12.00 | 7.70 | 14.28 | 287.00 | 769.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -6.0 | 10-JAN-07:00 | -7.0 | -9.0 | 0.00 | -20.0 | 0.00 | 0.00 |
February | -4.0 | 17-FEB-06:00 | -4.0 | -4.0 | 0.00 | -20.5 | 0.00 | 0.00 |
March | -1.0 | 08-MAR-06:00 | -1.4 | -2.0 | 0.00 | -14.4 | 17.50 | 184.50 |
April | 0.00 | 08-APR-04:00 | -0.9 | -2.0 | 0.00 | -12.7 | 0.00 | 0.00 |
May | 2.00 | 06-MAY-04:00 | 1.57 | 1.00 | 3.60 | -13.7 | 12.50 | 117.00 |
June | 6.00 | 01-JUN-03:00 | 5.05 | 4.00 | 0.00 | -9.2 | 0.00 | 0.00 |
July | 7.00 | 05-JUL-04:00 | 6.47 | 6.00 | 3.10 | -7.8 | 28.00 | 155.00 |
August | 8.00 | 20-AUG-04:00 | 7.45 | 7.00 | 0.00 | -6.6 | 0.00 | 0.00 |
September | 5.00 | 20-SEP-03:00 | 5.00 | 5.00 | 2.60 | -10.0 | 0.00 | 0.00 |
October | 2.00 | 07-OCT-03:00 | 2.00 | 2.00 | 0.00 | -13.4 | 0.00 | 0.00 |
November | -2.0 | 29-NOV-01:00 | -2.0 | -2.0 | 3.10 | -10.7 | 0.00 | 0.00 |
December | -3.0 | 29-DEC-20:00 | -4.5 | -7.0 | 3.60 | -20.2 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -6.0 | -7.0 | -9.0 | 0.00 | -20.5 | 0.00 | 0.00 | |
Maximum of Months | 8.00 | 7.45 | 7.00 | 3.60 | -6.6 | 28.00 | 184.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 12.44 | 29-JAN-04:00 | 13.00 | 12.00 | 0.00 | 9.13 | 0.00 | 0.00 |
February | 9.86 | 07-FEB-14:00 | 11.00 | 9.00 | 2.10 | 6.35 | 138.00 | 225.00 |
March | 12.00 | 19-MAR-11:00 | 12.00 | 12.00 | 2.60 | 8.15 | 131.00 | 0.00 |
April | 15.39 | 28-APR-07:00 | 16.00 | 15.00 | 0.00 | 5.54 | 119.50 | 626.00 |
May | 16.08 | 22-MAY-14:00 | 24.00 | 11.00 | 2.60 | 9.33 | 159.00 | 769.00 |
June | 19.93 | 25-JUN-17:00 | 22.00 | 19.00 | 0.00 | 15.94 | 136.50 | 360.50 |
July | 17.31 | 22-JUL-09:00 | 26.00 | 12.00 | 4.60 | 11.46 | 224.50 | 619.50 |
August | 17.06 | 14-AUG-12:00 | 24.00 | 13.00 | 2.60 | 9.91 | 205.50 | 669.50 |
September | 16.54 | 10-SEP-15:00 | 21.00 | 14.00 | 3.60 | 8.54 | 160.50 | 483.00 |
October | 13.58 | 17-OCT-14:00 | 16.00 | 12.00 | 0.00 | 12.03 | 144.00 | 44.50 |
November | 12.01 | 24-NOV-11:00 | 16.00 | 9.00 | 4.10 | 9.33 | 61.50 | 0.00 |
December | 7.93 | 02-DEC-12:00 | 9.00 | 7.00 | 0.00 | 2.01 | 135.50 | 84.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 7.93 | 9.00 | 7.00 | 0.00 | 2.01 | 0.00 | 0.00 | |
Maximum of Months | 19.93 | 26.00 | 19.00 | 4.60 | 15.94 | 224.50 | 769.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 12.00 | 29-JAN-04:00 | 13.00 | 12.44 | 0.00 | 9.13 | 0.00 | 0.00 |
February | 9.00 | 07-FEB-14:00 | 11.00 | 9.86 | 2.10 | 6.35 | 138.00 | 225.00 |
March | 12.00 | 19-MAR-11:00 | 12.00 | 12.00 | 2.60 | 8.15 | 131.00 | 0.00 |
April | 15.00 | 28-APR-07:00 | 16.00 | 15.39 | 0.00 | 5.54 | 119.50 | 626.00 |
May | 12.00 | 23-MAY-07:00 | 17.00 | 13.95 | 3.10 | 5.13 | 112.00 | 719.50 |
June | 19.00 | 25-JUN-17:00 | 22.00 | 19.93 | 0.00 | 15.94 | 136.50 | 360.50 |
July | 14.00 | 17-JUL-17:00 | 18.00 | 15.45 | 3.60 | 9.91 | 120.00 | 0.00 |
August | 16.00 | 08-AUG-12:00 | 18.00 | 16.70 | 1.50 | 11.46 | 154.00 | 0.00 |
September | 14.00 | 10-SEP-15:00 | 21.00 | 16.54 | 3.60 | 8.54 | 160.50 | 483.00 |
October | 13.00 | 17-OCT-18:00 | 13.00 | 13.00 | 2.60 | 9.33 | 0.00 | 0.00 |
November | 12.00 | 08-NOV-14:00 | 12.00 | 12.00 | 0.00 | 8.15 | 93.00 | 106.00 |
December | 7.00 | 02-DEC-11:00 | 8.00 | 7.45 | 3.10 | 1.16 | 144.50 | 146.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 7.00 | 8.00 | 7.45 | 0.00 | 1.16 | 0.00 | 0.00 | |
Maximum of Months | 19.00 | 22.00 | 19.93 | 3.60 | 15.94 | 160.50 | 719.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 10.33 | 8.85 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 10.00 | 14.79 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 10.33 | 17.09 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 11.26 | 40.86 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 12.54 | 47.73 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 13.82 | 50.98 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 14.77 | 51.67 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 15.12 | 44.67 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 14.78 | 34.25 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 13.84 | 17.71 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 12.55 | 9.34 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 11.27 | 6.14 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 12.57 | 28.73 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 10.00 | 6.14 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 15.12 | 51.67 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.493479E+10 | -0.469246E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -242330755.8 | 60.05 | 0.00 | 0.00 |
February | 0.450874E+10 | -0.429250E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -216242502.3 | 60.05 | 0.00 | 0.00 |
March | 0.528729E+10 | -0.504838E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -238913504.7 | 60.05 | 0.00 | 0.00 |
April | 0.468500E+10 | -0.445840E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -226598164.4 | 60.05 | 0.00 | 0.00 |
May | 0.489086E+10 | -0.465747E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -233381546.4 | 60.05 | 0.00 | 0.00 |
June | 0.473007E+10 | -0.450480E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -225267475.4 | 60.05 | 0.00 | 0.00 |
July | 0.438891E+10 | -0.415672E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -232183994.5 | 60.05 | 0.00 | 0.00 |
August | 0.479471E+10 | -0.456188E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -232824349.9 | 60.05 | 0.00 | 0.00 |
September | 0.436239E+10 | -0.413713E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -225256595.3 | 60.05 | 0.00 | 0.00 |
October | 0.459689E+10 | -0.436185E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -235043424.0 | 60.05 | 0.00 | 0.00 |
November | 0.463876E+10 | -0.440844E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -230326338.0 | 60.05 | 0.00 | 0.00 |
December | 0.471991E+10 | -0.447811E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -241804824.9 | 60.05 | 0.00 | 0.00 |
Annual Sum or Average | 0.565383E+11 | -0.537581E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.278017E+10 | 60.05 | 0.00 | 0.00 |
Minimum of Months | 0.436239E+10 | -0.504838E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -242330755.8 | 60.05 | 0.00 | 0.00 |
Maximum of Months | 0.528729E+10 | -0.413713E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -216242502.3 | 60.05 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_1_DAYLCTRL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 195.67 | 0.52 | 0.48 | 01-JAN-08:39 | 3998.42 | 36.20 | 191.00 | 221.50 | 3359.75 | 37.46 | 190.17 | 194.83 |
February | 217.00 | 0.51 | 0.48 | 01-FEB-11:39 | 5735.42 | 35.90 | 213.67 | 245.83 | 2739.84 | 31.78 | 200.00 | 222.00 |
March | 215.50 | 0.52 | 0.48 | 01-MAR-11:39 | 4223.70 | 30.95 | 182.17 | 310.00 | 1208.66 | 21.50 | 172.00 | 267.00 |
April | 359.67 | 0.51 | 0.48 | 01-APR-07:10 | 2654.10 | 19.57 | 25.67 | 354.50 | 1508.23 | 21.80 | 251.83 | 329.17 |
May | 417.17 | 0.51 | 0.48 | 01-MAY-06:00 | 2105.78 | 19.18 | 0.17 | 409.17 | 1187.32 | 21.40 | 258.33 | 373.17 |
June | 410.67 | 0.50 | 0.48 | 01-JUN-05:00 | 2045.99 | 19.48 | 0.00 | 412.00 | 1140.13 | 21.68 | 270.50 | 371.00 |
July | 429.00 | 0.51 | 0.48 | 01-JUL-05:00 | 2041.54 | 19.25 | 2.17 | 420.50 | 1167.00 | 21.47 | 268.17 | 382.50 |
August | 396.33 | 0.51 | 0.48 | 01-AUG-06:19 | 2370.44 | 19.22 | 17.00 | 381.67 | 1374.53 | 21.46 | 261.00 | 347.83 |
September | 337.67 | 0.51 | 0.48 | 01-SEP-07:49 | 3515.38 | 21.25 | 54.83 | 329.83 | 1674.10 | 22.00 | 230.50 | 303.17 |
October | 234.00 | 0.50 | 0.48 | 01-OCT-06:49 | 7253.79 | 35.03 | 216.83 | 279.67 | 2161.19 | 24.53 | 187.33 | 239.67 |
November | 171.33 | 0.51 | 0.48 | 01-NOV-11:39 | 4604.37 | 36.04 | 167.00 | 215.50 | 3847.55 | 37.37 | 168.00 | 173.17 |
December | 131.67 | 0.50 | 0.48 | 02-DEC-08:50 | 3871.70 | 37.08 | 128.50 | 182.17 | 3262.61 | 38.43 | 128.67 | 132.83 |
Annual Sum or Average | 3515.67 | 0.51 | 3302.02 | 24.71 | 1199.00 | 3762.33 | 1770.25 | 24.71 | 2586.50 | 3336.33 | ||
Minimum of Months | 131.67 | 0.50 | 0.48 | 2041.54 | 19.18 | 0.00 | 182.17 | 1140.13 | 21.40 | 128.67 | 132.83 | |
Maximum of Months | 429.00 | 0.52 | 0.48 | 7253.79 | 37.08 | 216.83 | 420.50 | 3847.55 | 38.43 | 270.50 | 382.50 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_2_DAYLCTRL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 195.67 | 0.54 | 0.48 | 01-JAN-08:39 | 1454.27 | 23.19 | 82.50 | 209.00 | 868.02 | 23.79 | 80.17 | 143.67 |
February | 217.00 | 0.51 | 0.48 | 01-FEB-11:39 | 1725.91 | 21.25 | 62.33 | 236.67 | 988.58 | 23.90 | 85.33 | 193.17 |
March | 215.50 | 0.52 | 0.48 | 01-MAR-11:39 | 1989.12 | 21.82 | 71.33 | 303.00 | 895.99 | 22.61 | 67.33 | 250.00 |
April | 359.67 | 0.51 | 0.48 | 01-APR-06:10 | 3695.34 | 22.82 | 107.17 | 363.33 | 2173.48 | 25.02 | 131.50 | 338.00 |
May | 417.17 | 0.50 | 0.48 | 01-MAY-06:40 | 3826.82 | 22.85 | 133.33 | 421.83 | 1725.88 | 22.74 | 76.83 | 381.00 |
June | 410.67 | 0.49 | 0.48 | 01-JUN-04:49 | 3844.44 | 22.75 | 129.50 | 419.50 | 1765.92 | 23.54 | 81.50 | 388.17 |
July | 429.00 | 0.50 | 0.48 | 01-JUL-04:49 | 3763.05 | 23.00 | 139.67 | 430.50 | 1719.42 | 23.59 | 90.00 | 400.67 |
August | 396.33 | 0.50 | 0.48 | 01-AUG-05:30 | 3631.10 | 23.34 | 127.83 | 389.83 | 1608.15 | 23.06 | 89.00 | 360.17 |
September | 337.67 | 0.50 | 0.48 | 01-SEP-07:40 | 3432.81 | 23.62 | 109.33 | 337.00 | 1904.80 | 24.46 | 130.17 | 306.17 |
October | 234.00 | 0.51 | 0.48 | 01-OCT-06:40 | 2678.24 | 23.05 | 82.33 | 271.50 | 1235.52 | 23.77 | 99.50 | 213.83 |
November | 171.33 | 0.53 | 0.48 | 01-NOV-11:00 | 1454.21 | 21.35 | 55.67 | 202.33 | 854.42 | 23.74 | 79.67 | 135.17 |
December | 131.67 | 0.52 | 0.48 | 02-DEC-08:50 | 1253.51 | 23.77 | 52.67 | 163.83 | 877.24 | 25.90 | 70.83 | 98.17 |
Annual Sum or Average | 3515.67 | 0.51 | 3084.92 | 22.82 | 1153.67 | 3748.33 | 1528.46 | 23.73 | 1081.83 | 3208.17 | ||
Minimum of Months | 131.67 | 0.49 | 0.48 | 1253.51 | 21.25 | 52.67 | 163.83 | 854.42 | 22.61 | 67.33 | 98.17 | |
Maximum of Months | 429.00 | 0.54 | 0.48 | 3844.44 | 23.77 | 139.67 | 430.50 | 2173.48 | 25.90 | 131.50 | 400.67 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_3_DAYLCTRL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 195.67 | 0.59 | 0.48 | 01-JAN-10:39 | 526.46 | 14.46 | 0.00 | 185.33 | 307.16 | 16.85 | 0.00 | 72.17 |
February | 217.00 | 0.55 | 0.48 | 01-FEB-12:09 | 697.83 | 16.23 | 0.00 | 222.00 | 409.64 | 18.53 | 0.00 | 140.00 |
March | 215.50 | 0.53 | 0.48 | 01-MAR-11:39 | 862.63 | 17.00 | 0.00 | 299.17 | 469.45 | 19.06 | 3.17 | 217.67 |
April | 359.67 | 0.51 | 0.48 | 01-APR-07:19 | 1141.16 | 18.78 | 0.00 | 360.33 | 681.93 | 20.90 | 106.50 | 328.33 |
May | 417.17 | 0.50 | 0.48 | 01-MAY-06:00 | 1354.35 | 20.66 | 46.33 | 425.33 | 780.80 | 22.78 | 214.33 | 398.67 |
June | 410.67 | 0.49 | 0.48 | 01-JUN-04:00 | 1543.07 | 21.79 | 84.33 | 427.33 | 888.37 | 23.85 | 250.17 | 403.50 |
July | 429.00 | 0.49 | 0.48 | 01-JUL-04:00 | 1433.64 | 21.57 | 72.83 | 438.67 | 844.49 | 23.66 | 255.67 | 416.17 |
August | 396.33 | 0.51 | 0.48 | 01-AUG-05:00 | 1160.55 | 18.82 | 0.00 | 391.17 | 703.27 | 21.01 | 145.17 | 359.50 |
September | 337.67 | 0.52 | 0.48 | 01-SEP-07:00 | 933.16 | 18.14 | 0.00 | 325.17 | 585.95 | 20.40 | 23.33 | 281.17 |
October | 234.00 | 0.53 | 0.48 | 01-OCT-07:49 | 790.60 | 16.93 | 0.00 | 261.67 | 474.77 | 19.21 | 0.50 | 176.33 |
November | 171.33 | 0.57 | 0.48 | 01-NOV-12:20 | 583.74 | 15.25 | 0.00 | 178.67 | 342.63 | 17.59 | 0.00 | 76.67 |
December | 131.67 | 0.60 | 0.48 | 02-DEC-10:00 | 493.97 | 14.64 | 0.00 | 128.83 | 292.12 | 17.13 | 0.00 | 38.83 |
Annual Sum or Average | 3515.67 | 0.52 | 1077.92 | 18.68 | 203.50 | 3643.67 | 635.19 | 20.87 | 998.83 | 2909.00 | ||
Minimum of Months | 131.67 | 0.49 | 0.48 | 493.97 | 14.46 | 0.00 | 128.83 | 292.12 | 16.85 | 0.00 | 38.83 | |
Maximum of Months | 429.00 | 0.60 | 0.48 | 1543.07 | 21.79 | 84.33 | 438.67 | 888.37 | 23.85 | 255.67 | 416.17 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_4_DAYLCTRL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 195.67 | 0.56 | 0.48 | 01-JAN-10:30 | 1269.35 | 20.25 | 64.50 | 201.00 | 755.42 | 22.91 | 75.83 | 143.33 |
February | 217.00 | 0.53 | 0.48 | 01-FEB-11:39 | 2013.21 | 20.86 | 58.33 | 232.17 | 1113.95 | 22.75 | 78.17 | 180.83 |
March | 215.50 | 0.53 | 0.48 | 01-MAR-11:39 | 1881.95 | 21.72 | 72.33 | 302.50 | 1023.63 | 22.71 | 71.00 | 249.17 |
April | 359.67 | 0.51 | 0.48 | 01-APR-08:09 | 3568.05 | 21.75 | 102.33 | 354.50 | 1621.10 | 21.83 | 81.50 | 326.83 |
May | 417.17 | 0.51 | 0.48 | 01-MAY-07:19 | 3206.76 | 19.52 | 73.83 | 411.17 | 1798.22 | 21.17 | 47.17 | 381.67 |
June | 410.67 | 0.50 | 0.48 | 01-JUN-06:10 | 3739.85 | 18.61 | 50.67 | 416.50 | 1678.06 | 19.58 | 1.67 | 378.83 |
July | 429.00 | 0.50 | 0.48 | 01-JUL-06:10 | 3711.47 | 18.50 | 53.33 | 426.50 | 1706.56 | 19.53 | 4.50 | 393.67 |
August | 396.33 | 0.51 | 0.48 | 01-AUG-06:30 | 3294.37 | 20.43 | 86.83 | 381.00 | 1853.16 | 21.77 | 75.17 | 349.00 |
September | 337.67 | 0.52 | 0.48 | 01-SEP-08:20 | 3189.96 | 22.09 | 96.83 | 322.83 | 1766.93 | 23.39 | 102.00 | 295.33 |
October | 234.00 | 0.52 | 0.48 | 01-OCT-07:00 | 2524.97 | 22.45 | 79.83 | 268.00 | 1152.04 | 23.01 | 96.17 | 209.17 |
November | 171.33 | 0.54 | 0.48 | 01-NOV-11:00 | 1417.49 | 20.61 | 51.67 | 194.00 | 776.91 | 22.59 | 71.00 | 130.83 |
December | 131.67 | 0.56 | 0.48 | 02-DEC-10:20 | 1033.58 | 20.18 | 37.67 | 157.33 | 543.32 | 20.68 | 39.17 | 81.33 |
Annual Sum or Average | 3515.67 | 0.52 | 2899.17 | 20.40 | 828.17 | 3667.50 | 1470.53 | 21.59 | 743.33 | 3120.00 | ||
Minimum of Months | 131.67 | 0.50 | 0.48 | 1033.58 | 18.50 | 37.67 | 157.33 | 543.32 | 19.53 | 1.67 | 81.33 | |
Maximum of Months | 429.00 | 0.56 | 0.48 | 3739.85 | 22.45 | 102.33 | 426.50 | 1853.16 | 23.39 | 102.00 | 393.67 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_1_DAYLCTRL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 195.67 | 0.52 | 0.48 | 01-JAN-08:39 | 3821.37 | 33.98 | 177.17 | 220.00 | 3255.89 | 37.24 | 190.00 | 191.33 |
February | 217.00 | 0.51 | 0.48 | 01-FEB-11:39 | 5582.34 | 35.67 | 213.50 | 245.00 | 2622.53 | 30.43 | 141.83 | 219.50 |
March | 215.50 | 0.52 | 0.48 | 01-MAR-11:39 | 4115.56 | 30.17 | 181.17 | 308.67 | 1136.48 | 18.53 | 7.83 | 263.17 |
April | 359.67 | 0.52 | 0.48 | 01-APR-07:19 | 2520.34 | 15.86 | 0.00 | 353.50 | 1411.67 | 19.38 | 39.83 | 326.50 |
May | 417.17 | 0.51 | 0.48 | 01-MAY-06:00 | 2010.02 | 15.52 | 0.00 | 407.33 | 1121.64 | 19.00 | 15.50 | 371.17 |
June | 410.67 | 0.50 | 0.48 | 01-JUN-06:10 | 1958.53 | 15.84 | 0.00 | 409.33 | 1082.38 | 19.29 | 7.83 | 368.00 |
July | 429.00 | 0.51 | 0.48 | 01-JUL-06:10 | 1949.35 | 15.63 | 0.00 | 418.67 | 1104.31 | 19.12 | 17.00 | 378.67 |
August | 396.33 | 0.52 | 0.48 | 01-AUG-06:19 | 2251.27 | 15.53 | 0.00 | 380.17 | 1288.86 | 19.05 | 37.33 | 344.33 |
September | 337.67 | 0.51 | 0.48 | 01-SEP-07:49 | 3357.85 | 17.74 | 29.50 | 328.17 | 1554.77 | 19.48 | 45.50 | 300.50 |
October | 234.00 | 0.51 | 0.48 | 01-OCT-06:00 | 7081.08 | 34.59 | 216.17 | 278.83 | 2034.41 | 21.96 | 45.83 | 236.50 |
November | 171.33 | 0.51 | 0.48 | 01-NOV-11:39 | 4450.68 | 35.79 | 166.83 | 213.50 | 3739.35 | 37.16 | 167.50 | 170.50 |
December | 131.67 | 0.51 | 0.48 | 02-DEC-08:50 | 3714.96 | 36.27 | 126.00 | 179.67 | 3154.58 | 38.20 | 128.67 | 129.67 |
Annual Sum or Average | 3515.67 | 0.51 | 3176.16 | 22.02 | 1110.33 | 3742.83 | 1681.86 | 22.63 | 844.67 | 3299.83 | ||
Minimum of Months | 131.67 | 0.50 | 0.48 | 1949.35 | 15.52 | 0.00 | 179.67 | 1082.38 | 18.53 | 7.83 | 129.67 | |
Maximum of Months | 429.00 | 0.52 | 0.48 | 7081.08 | 36.27 | 216.17 | 418.67 | 3739.35 | 38.20 | 190.00 | 378.67 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_2_DAYLCTRL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 195.67 | 0.55 | 0.48 | 01-JAN-08:39 | 1413.27 | 22.77 | 82.50 | 207.00 | 837.18 | 23.56 | 77.00 | 138.17 |
February | 217.00 | 0.52 | 0.48 | 01-FEB-11:39 | 1670.85 | 20.75 | 62.33 | 234.83 | 946.14 | 23.67 | 80.83 | 188.83 |
March | 215.50 | 0.53 | 0.48 | 01-MAR-11:39 | 1933.33 | 21.37 | 71.33 | 301.67 | 854.94 | 22.40 | 60.50 | 245.33 |
April | 359.67 | 0.51 | 0.48 | 01-APR-06:19 | 3587.14 | 22.37 | 107.17 | 362.17 | 2045.18 | 23.65 | 97.83 | 333.33 |
May | 417.17 | 0.50 | 0.48 | 01-MAY-06:40 | 3733.03 | 22.41 | 133.33 | 420.17 | 1652.87 | 22.56 | 72.33 | 377.33 |
June | 410.67 | 0.49 | 0.48 | 01-JUN-04:49 | 3749.07 | 22.31 | 129.50 | 418.00 | 1694.86 | 23.34 | 81.00 | 384.83 |
July | 429.00 | 0.50 | 0.48 | 01-JUL-04:49 | 3660.56 | 22.42 | 137.67 | 428.83 | 1638.21 | 22.80 | 78.33 | 397.00 |
August | 396.33 | 0.51 | 0.48 | 01-AUG-05:30 | 3489.34 | 21.53 | 109.83 | 387.00 | 1532.90 | 22.88 | 78.17 | 356.33 |
September | 337.67 | 0.50 | 0.48 | 01-SEP-07:40 | 3335.62 | 23.17 | 109.33 | 335.00 | 1821.18 | 24.09 | 117.83 | 302.50 |
October | 234.00 | 0.51 | 0.48 | 01-OCT-06:49 | 2605.09 | 22.60 | 82.33 | 268.83 | 1143.88 | 22.52 | 84.33 | 208.83 |
November | 171.33 | 0.53 | 0.48 | 01-NOV-11:00 | 1407.84 | 20.87 | 55.67 | 199.17 | 820.40 | 23.51 | 74.67 | 128.00 |
December | 131.67 | 0.53 | 0.48 | 02-DEC-08:50 | 1203.27 | 22.81 | 50.17 | 160.00 | 846.22 | 25.69 | 67.00 | 96.00 |
Annual Sum or Average | 3515.67 | 0.51 | 2995.65 | 22.18 | 1131.17 | 3722.67 | 1456.17 | 23.25 | 969.83 | 3156.50 | ||
Minimum of Months | 131.67 | 0.49 | 0.48 | 1203.27 | 20.75 | 50.17 | 160.00 | 820.40 | 22.40 | 60.50 | 96.00 | |
Maximum of Months | 429.00 | 0.55 | 0.48 | 3749.07 | 23.17 | 137.67 | 428.83 | 2045.18 | 25.69 | 117.83 | 397.00 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_3_DAYLCTRL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 195.67 | 0.60 | 0.48 | 01-JAN-10:50 | 505.49 | 10.74 | 0.00 | 182.17 | 295.45 | 14.34 | 0.00 | 63.00 |
February | 217.00 | 0.55 | 0.48 | 01-FEB-12:20 | 671.10 | 12.62 | 0.00 | 220.00 | 394.84 | 16.18 | 0.00 | 130.67 |
March | 215.50 | 0.53 | 0.48 | 01-MAR-11:39 | 832.43 | 13.21 | 0.00 | 297.00 | 451.94 | 16.58 | 0.00 | 204.17 |
April | 359.67 | 0.51 | 0.48 | 01-APR-07:30 | 1100.39 | 15.62 | 0.00 | 359.00 | 659.80 | 19.08 | 8.67 | 324.17 |
May | 417.17 | 0.50 | 0.48 | 01-MAY-06:00 | 1306.73 | 17.57 | 38.00 | 423.33 | 754.09 | 20.87 | 73.00 | 395.17 |
June | 410.67 | 0.49 | 0.48 | 01-JUN-04:00 | 1488.61 | 18.78 | 56.83 | 426.00 | 857.15 | 21.99 | 105.50 | 401.33 |
July | 429.00 | 0.49 | 0.48 | 01-JUL-04:00 | 1375.76 | 17.40 | 34.00 | 436.67 | 815.74 | 21.87 | 107.00 | 413.50 |
August | 396.33 | 0.51 | 0.48 | 01-AUG-05:00 | 1118.66 | 15.55 | 0.00 | 390.17 | 680.66 | 19.10 | 13.33 | 356.83 |
September | 337.67 | 0.52 | 0.48 | 01-SEP-08:09 | 898.27 | 15.05 | 0.00 | 322.17 | 567.58 | 18.59 | 0.00 | 277.00 |
October | 234.00 | 0.53 | 0.48 | 01-OCT-07:00 | 760.51 | 13.51 | 0.00 | 258.67 | 458.35 | 17.03 | 0.00 | 169.83 |
November | 171.33 | 0.57 | 0.48 | 01-NOV-12:20 | 560.68 | 11.49 | 0.00 | 174.50 | 329.81 | 15.10 | 0.00 | 71.17 |
December | 131.67 | 0.60 | 0.48 | 02-DEC-11:09 | 473.73 | 10.71 | 0.00 | 123.00 | 280.89 | 14.50 | 0.00 | 34.17 |
Annual Sum or Average | 3515.67 | 0.52 | 1038.04 | 15.25 | 128.83 | 3612.67 | 613.51 | 18.83 | 307.50 | 2841.00 | ||
Minimum of Months | 131.67 | 0.49 | 0.48 | 473.73 | 10.71 | 0.00 | 123.00 | 280.89 | 14.34 | 0.00 | 34.17 | |
Maximum of Months | 429.00 | 0.60 | 0.48 | 1488.61 | 18.78 | 56.83 | 436.67 | 857.15 | 21.99 | 107.00 | 413.50 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_4_DAYLCTRL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 195.67 | 0.56 | 0.48 | 01-JAN-10:30 | 1228.96 | 19.86 | 64.33 | 199.00 | 725.49 | 22.81 | 75.67 | 137.33 |
February | 217.00 | 0.53 | 0.48 | 01-FEB-11:39 | 1949.26 | 20.44 | 58.33 | 230.17 | 1024.79 | 21.47 | 69.00 | 176.33 |
March | 215.50 | 0.53 | 0.48 | 01-MAR-11:39 | 1827.92 | 21.33 | 72.33 | 301.67 | 982.70 | 22.49 | 67.50 | 245.17 |
April | 359.67 | 0.52 | 0.48 | 01-APR-08:20 | 3402.30 | 21.32 | 102.00 | 351.67 | 1552.44 | 21.69 | 76.17 | 323.00 |
May | 417.17 | 0.51 | 0.48 | 01-MAY-07:19 | 3113.67 | 19.06 | 73.83 | 409.83 | 1727.00 | 21.01 | 46.83 | 380.00 |
June | 410.67 | 0.50 | 0.48 | 01-JUN-06:19 | 3638.44 | 18.13 | 50.50 | 414.33 | 1600.79 | 19.42 | 0.00 | 376.67 |
July | 429.00 | 0.51 | 0.48 | 01-JUL-06:10 | 3610.51 | 18.01 | 53.33 | 425.33 | 1626.46 | 19.37 | 3.67 | 390.83 |
August | 396.33 | 0.52 | 0.48 | 01-AUG-06:40 | 3201.37 | 19.99 | 86.83 | 379.67 | 1767.66 | 21.62 | 71.50 | 346.00 |
September | 337.67 | 0.52 | 0.48 | 01-SEP-08:20 | 3106.21 | 21.66 | 96.83 | 321.00 | 1677.79 | 23.00 | 96.17 | 290.83 |
October | 234.00 | 0.52 | 0.48 | 01-OCT-07:00 | 2456.00 | 22.07 | 79.83 | 266.67 | 1076.23 | 22.04 | 87.83 | 205.33 |
November | 171.33 | 0.55 | 0.48 | 01-NOV-11:00 | 1372.76 | 20.21 | 51.67 | 191.50 | 744.35 | 22.49 | 70.17 | 126.17 |
December | 131.67 | 0.56 | 0.48 | 02-DEC-10:30 | 1000.79 | 19.78 | 37.67 | 151.50 | 519.88 | 20.58 | 38.50 | 78.50 |
Annual Sum or Average | 3515.67 | 0.52 | 2810.97 | 19.96 | 827.50 | 3642.33 | 1400.87 | 21.30 | 703.00 | 3076.17 | ||
Minimum of Months | 131.67 | 0.50 | 0.48 | 1000.79 | 18.01 | 37.67 | 151.50 | 519.88 | 19.37 | 0.00 | 78.50 | |
Maximum of Months | 429.00 | 0.56 | 0.48 | 3638.44 | 22.07 | 102.00 | 425.33 | 1767.66 | 23.00 | 96.17 | 390.83 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_1_DAYLCTRL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 195.67 | 0.52 | 0.48 | 01-JAN-08:39 | 3821.38 | 33.98 | 177.17 | 220.00 | 3255.81 | 37.24 | 190.00 | 191.33 |
February | 217.00 | 0.51 | 0.48 | 01-FEB-11:39 | 5582.31 | 35.67 | 213.50 | 245.00 | 2622.42 | 30.43 | 141.83 | 219.50 |
March | 215.50 | 0.52 | 0.48 | 01-MAR-11:39 | 4115.43 | 30.17 | 181.17 | 308.67 | 1136.36 | 18.53 | 7.83 | 263.17 |
April | 359.67 | 0.52 | 0.48 | 01-APR-07:19 | 2520.19 | 15.86 | 0.00 | 353.50 | 1411.56 | 19.38 | 39.83 | 326.50 |
May | 417.17 | 0.51 | 0.48 | 01-MAY-06:00 | 2009.90 | 15.52 | 0.00 | 407.33 | 1121.56 | 19.00 | 15.67 | 371.17 |
June | 410.67 | 0.50 | 0.48 | 01-JUN-06:10 | 1958.41 | 15.84 | 0.00 | 409.33 | 1082.30 | 19.29 | 7.83 | 368.00 |
July | 429.00 | 0.51 | 0.48 | 01-JUL-06:10 | 1949.24 | 15.63 | 0.00 | 418.67 | 1104.23 | 19.12 | 17.17 | 378.67 |
August | 396.33 | 0.52 | 0.48 | 01-AUG-06:19 | 2251.15 | 15.53 | 0.00 | 380.17 | 1288.77 | 19.05 | 37.33 | 344.33 |
September | 337.67 | 0.51 | 0.48 | 01-SEP-07:49 | 3357.73 | 17.74 | 29.50 | 328.17 | 1554.65 | 19.48 | 45.50 | 300.50 |
October | 234.00 | 0.51 | 0.48 | 01-OCT-06:00 | 7081.03 | 34.59 | 216.17 | 278.83 | 2034.28 | 21.96 | 45.83 | 236.50 |
November | 171.33 | 0.51 | 0.48 | 01-NOV-11:39 | 4450.68 | 35.79 | 166.83 | 213.50 | 3739.26 | 37.16 | 167.50 | 170.50 |
December | 131.67 | 0.51 | 0.48 | 02-DEC-08:50 | 3714.99 | 36.27 | 126.00 | 179.67 | 3154.51 | 38.20 | 128.67 | 129.67 |
Annual Sum or Average | 3515.67 | 0.51 | 3176.06 | 22.02 | 1110.33 | 3742.83 | 1681.76 | 22.63 | 845.00 | 3299.83 | ||
Minimum of Months | 131.67 | 0.50 | 0.48 | 1949.24 | 15.52 | 0.00 | 179.67 | 1082.30 | 18.53 | 7.83 | 129.67 | |
Maximum of Months | 429.00 | 0.52 | 0.48 | 7081.03 | 36.27 | 216.17 | 418.67 | 3739.26 | 38.20 | 190.00 | 378.67 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_2_DAYLCTRL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 195.67 | 0.55 | 0.48 | 01-JAN-08:39 | 1413.25 | 22.77 | 82.50 | 207.00 | 837.14 | 23.56 | 77.00 | 138.17 |
February | 217.00 | 0.52 | 0.48 | 01-FEB-11:39 | 1670.82 | 20.75 | 62.33 | 234.83 | 946.09 | 23.67 | 80.83 | 188.83 |
March | 215.50 | 0.53 | 0.48 | 01-MAR-11:39 | 1933.26 | 21.37 | 71.33 | 301.67 | 854.87 | 22.40 | 60.50 | 245.33 |
April | 359.67 | 0.51 | 0.48 | 01-APR-06:19 | 3587.09 | 22.37 | 107.17 | 362.17 | 2045.10 | 23.65 | 98.00 | 333.33 |
May | 417.17 | 0.50 | 0.48 | 01-MAY-06:40 | 3732.96 | 22.41 | 133.33 | 420.17 | 1652.78 | 22.56 | 72.33 | 377.33 |
June | 410.67 | 0.49 | 0.48 | 01-JUN-04:49 | 3748.99 | 22.32 | 129.50 | 418.00 | 1694.77 | 23.34 | 81.00 | 384.83 |
July | 429.00 | 0.50 | 0.48 | 01-JUL-04:49 | 3660.49 | 22.42 | 137.67 | 428.83 | 1638.12 | 22.80 | 78.33 | 397.00 |
August | 396.33 | 0.51 | 0.48 | 01-AUG-05:30 | 3489.29 | 21.53 | 109.83 | 387.00 | 1532.83 | 22.88 | 78.17 | 356.33 |
September | 337.67 | 0.50 | 0.48 | 01-SEP-07:40 | 3335.60 | 23.17 | 109.33 | 335.00 | 1821.11 | 24.09 | 118.00 | 302.50 |
October | 234.00 | 0.51 | 0.48 | 01-OCT-06:49 | 2605.06 | 22.60 | 82.33 | 268.83 | 1143.82 | 22.52 | 84.33 | 208.83 |
November | 171.33 | 0.53 | 0.48 | 01-NOV-11:00 | 1407.81 | 20.87 | 55.67 | 199.17 | 820.35 | 23.51 | 74.67 | 128.00 |
December | 131.67 | 0.53 | 0.48 | 02-DEC-08:50 | 1203.26 | 22.81 | 50.17 | 160.00 | 846.19 | 25.69 | 67.00 | 95.83 |
Annual Sum or Average | 3515.67 | 0.51 | 2995.60 | 22.18 | 1131.17 | 3722.67 | 1456.10 | 23.25 | 970.17 | 3156.33 | ||
Minimum of Months | 131.67 | 0.49 | 0.48 | 1203.26 | 20.75 | 50.17 | 160.00 | 820.35 | 22.40 | 60.50 | 95.83 | |
Maximum of Months | 429.00 | 0.55 | 0.48 | 3748.99 | 23.17 | 137.67 | 428.83 | 2045.10 | 25.69 | 118.00 | 397.00 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_3_DAYLCTRL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 195.67 | 0.60 | 0.48 | 01-JAN-10:50 | 505.47 | 10.74 | 0.00 | 182.17 | 295.43 | 14.34 | 0.00 | 63.00 |
February | 217.00 | 0.55 | 0.48 | 01-FEB-12:20 | 671.08 | 12.62 | 0.00 | 220.00 | 394.81 | 16.18 | 0.00 | 130.67 |
March | 215.50 | 0.53 | 0.48 | 01-MAR-11:39 | 832.39 | 13.22 | 0.00 | 297.00 | 451.90 | 16.59 | 0.00 | 204.17 |
April | 359.67 | 0.51 | 0.48 | 01-APR-07:30 | 1100.35 | 15.62 | 0.00 | 359.00 | 659.75 | 19.08 | 8.67 | 324.17 |
May | 417.17 | 0.50 | 0.48 | 01-MAY-06:00 | 1306.68 | 17.57 | 38.00 | 423.33 | 754.04 | 20.87 | 73.17 | 395.17 |
June | 410.67 | 0.49 | 0.48 | 01-JUN-04:00 | 1488.55 | 18.78 | 56.83 | 426.00 | 857.09 | 21.99 | 105.50 | 401.33 |
July | 429.00 | 0.49 | 0.48 | 01-JUL-04:00 | 1375.72 | 17.40 | 34.00 | 436.67 | 815.69 | 21.87 | 107.00 | 413.50 |
August | 396.33 | 0.51 | 0.48 | 01-AUG-05:00 | 1118.63 | 15.56 | 0.00 | 390.17 | 680.61 | 19.10 | 13.33 | 356.83 |
September | 337.67 | 0.52 | 0.48 | 01-SEP-08:09 | 898.26 | 15.06 | 0.00 | 322.17 | 567.55 | 18.59 | 0.00 | 277.00 |
October | 234.00 | 0.53 | 0.48 | 01-OCT-07:00 | 760.49 | 13.51 | 0.00 | 258.67 | 458.32 | 17.03 | 0.00 | 169.83 |
November | 171.33 | 0.57 | 0.48 | 01-NOV-12:20 | 560.66 | 11.50 | 0.00 | 174.50 | 329.79 | 15.11 | 0.00 | 71.17 |
December | 131.67 | 0.60 | 0.48 | 02-DEC-11:09 | 473.72 | 10.71 | 0.00 | 123.00 | 280.87 | 14.50 | 0.00 | 34.17 |
Annual Sum or Average | 3515.67 | 0.52 | 1038.01 | 15.25 | 128.83 | 3612.67 | 613.47 | 18.83 | 307.67 | 2841.00 | ||
Minimum of Months | 131.67 | 0.49 | 0.48 | 473.72 | 10.71 | 0.00 | 123.00 | 280.87 | 14.34 | 0.00 | 34.17 | |
Maximum of Months | 429.00 | 0.60 | 0.48 | 1488.55 | 18.78 | 56.83 | 436.67 | 857.09 | 21.99 | 107.00 | 413.50 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_4_DAYLCTRL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 195.67 | 0.56 | 0.48 | 01-JAN-10:30 | 1228.94 | 19.87 | 64.33 | 199.00 | 725.45 | 22.82 | 75.67 | 137.33 |
February | 217.00 | 0.53 | 0.48 | 01-FEB-11:39 | 1949.24 | 20.44 | 58.33 | 230.17 | 1024.73 | 21.47 | 69.00 | 176.17 |
March | 215.50 | 0.53 | 0.48 | 01-MAR-11:39 | 1827.85 | 21.33 | 72.33 | 301.67 | 982.63 | 22.49 | 67.50 | 245.17 |
April | 359.67 | 0.52 | 0.48 | 01-APR-08:20 | 3402.24 | 21.32 | 102.00 | 351.67 | 1552.35 | 21.69 | 76.17 | 323.00 |
May | 417.17 | 0.51 | 0.48 | 01-MAY-07:19 | 3113.60 | 19.06 | 73.83 | 409.83 | 1726.91 | 21.01 | 46.83 | 380.00 |
June | 410.67 | 0.50 | 0.48 | 01-JUN-06:19 | 3638.36 | 18.13 | 50.50 | 414.33 | 1600.70 | 19.42 | 0.00 | 376.67 |
July | 429.00 | 0.51 | 0.48 | 01-JUL-06:10 | 3610.44 | 18.01 | 53.33 | 425.33 | 1626.38 | 19.37 | 3.67 | 390.83 |
August | 396.33 | 0.52 | 0.48 | 01-AUG-06:40 | 3201.32 | 19.99 | 86.83 | 379.67 | 1767.58 | 21.62 | 71.50 | 346.00 |
September | 337.67 | 0.52 | 0.48 | 01-SEP-08:20 | 3106.18 | 21.66 | 96.83 | 321.00 | 1677.72 | 23.00 | 96.17 | 290.83 |
October | 234.00 | 0.52 | 0.48 | 01-OCT-07:00 | 2455.97 | 22.07 | 79.83 | 266.67 | 1076.17 | 22.04 | 87.83 | 205.33 |
November | 171.33 | 0.55 | 0.48 | 01-NOV-11:00 | 1372.74 | 20.22 | 51.67 | 191.50 | 744.30 | 22.49 | 70.17 | 126.00 |
December | 131.67 | 0.56 | 0.48 | 02-DEC-10:30 | 1000.77 | 19.78 | 37.67 | 151.33 | 519.84 | 20.58 | 38.50 | 78.50 |
Annual Sum or Average | 3515.67 | 0.52 | 2810.92 | 19.96 | 827.50 | 3642.17 | 1400.80 | 21.30 | 703.00 | 3075.83 | ||
Minimum of Months | 131.67 | 0.50 | 0.48 | 1000.77 | 18.01 | 37.67 | 151.33 | 519.84 | 19.37 | 0.00 | 78.50 | |
Maximum of Months | 429.00 | 0.56 | 0.48 | 3638.36 | 22.07 | 102.00 | 425.33 | 1767.58 | 23.00 | 96.17 | 390.83 |
Report: CoilReportMonthly
For: PACU_VAV_BOT HEATING COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.516947E+10 | 14770.95 | 10-JAN-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.309700E+10 | 12466.00 | 17-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.224327E+10 | 8948.57 | 08-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.181009E+09 | 6908.76 | 08-APR-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 21119325.59 | 4074.50 | 06-MAY-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 183308.45 | 5.16 | 13-JUN-14:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 174742.70 | 4.57 | 17-JUL-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 196925.85 | 4.78 | 14-AUG-15:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 215628.05 | 731.69 | 21-SEP-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.167779E+09 | 4246.17 | 07-OCT-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.172119E+10 | 9879.53 | 29-NOV-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.460338E+10 | 11119.29 | 29-DEC-21:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.172050E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 174742.70 | 4.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.516947E+10 | 14770.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_BOTTOM VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 12426400.94 | 10052.91 | 02-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 12426400.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 12426400.94 | 10052.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.386118E+10 | 8025.62 | 10-JAN-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.279796E+10 | 7993.43 | 08-FEB-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.353543E+10 | 7994.84 | 20-MAR-05:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.103572E+10 | 8077.49 | 24-APR-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.106563E+10 | 8296.51 | 02-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.448301E+09 | 8077.98 | 07-JUN-06:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.168465E+09 | 8067.84 | 05-JUL-06:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.155995E+09 | 8061.39 | 30-AUG-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.382411E+09 | 8081.21 | 20-SEP-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.139862E+10 | 8110.75 | 04-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.260323E+10 | 7997.21 | 24-NOV-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.408159E+10 | 7992.41 | 05-DEC-06:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.215345E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.155995E+09 | 7992.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.408159E+10 | 8296.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.121290E+10 | 5329.14 | 02-JAN-07:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.711692E+09 | 5313.62 | 13-FEB-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.603375E+09 | 5311.69 | 20-MAR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 5946747.41 | 5299.79 | 03-APR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 85790291.31 | 5303.15 | 17-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.440259E+09 | 5308.36 | 30-NOV-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.121457E+10 | 5310.26 | 05-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.427453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.121457E+10 | 5329.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.193026E+10 | 5606.86 | 02-JAN-07:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.115300E+10 | 5596.00 | 27-FEB-06:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.856138E+09 | 5594.37 | 17-MAR-06:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 56073785.56 | 5581.09 | 11-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.107263E+09 | 5586.05 | 16-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.636719E+09 | 5595.06 | 13-NOV-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.175252E+10 | 5595.59 | 18-DEC-06:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.649197E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.193026E+10 | 5606.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.138976E+10 | 5574.43 | 02-JAN-07:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.771985E+09 | 5558.48 | 13-FEB-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.713260E+09 | 5556.03 | 20-MAR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 37764091.44 | 5548.86 | 11-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 3243455.94 | 2312.65 | 05-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.130284E+09 | 5552.60 | 20-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.560303E+09 | 5552.87 | 30-NOV-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.148277E+10 | 5554.93 | 04-DEC-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.508937E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.148277E+10 | 5574.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_MID HEATING COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.619399E+10 | 14899.75 | 10-JAN-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.433420E+10 | 13451.52 | 17-FEB-07:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.343480E+10 | 9996.74 | 08-MAR-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.457497E+09 | 7751.85 | 08-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 84403290.54 | 4800.43 | 06-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 425998.71 | 322.37 | 07-JUN-21:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 158447.18 | 4.29 | 21-JUL-13:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 174650.75 | 4.34 | 14-AUG-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 14454088.83 | 2660.82 | 21-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.513695E+09 | 5716.54 | 23-OCT-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.274036E+10 | 10951.33 | 29-NOV-07:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.597220E+10 | 12132.62 | 29-DEC-21:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.237464E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 158447.18 | 4.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.619399E+10 | 14899.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_MID VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.534897E+09 | 14174.20 | 03-JAN-07:14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 45947925.53 | 14171.10 | 21-FEB-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 28796855.33 | 14176.73 | 06-MAR-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 41786506.07 | 14105.72 | 27-NOV-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.461506E+09 | 14179.36 | 12-DEC-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.111293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.534897E+09 | 14179.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.122806E+10 | 8366.35 | 30-JAN-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.667623E+09 | 8364.85 | 06-FEB-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.593838E+09 | 8364.83 | 07-MAR-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 31430995.46 | 8326.05 | 11-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 2098261.44 | 3380.41 | 05-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.143406E+09 | 8321.64 | 27-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.598052E+09 | 8363.39 | 20-NOV-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.162342E+10 | 8364.79 | 06-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.488793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.162342E+10 | 8366.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.128446E+10 | 5709.29 | 09-JAN-07:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.767677E+09 | 5711.71 | 13-FEB-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.578585E+09 | 5701.68 | 07-MAR-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 11377568.14 | 5664.90 | 03-APR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 607695.26 | 1106.33 | 17-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.180972E+09 | 5683.56 | 18-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.692979E+09 | 5700.79 | 20-NOV-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.149736E+10 | 5709.76 | 26-DEC-07:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.501402E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.149736E+10 | 5711.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.152755E+10 | 5914.08 | 23-JAN-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.840059E+09 | 5902.95 | 21-FEB-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.518733E+09 | 5905.16 | 06-MAR-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 20593804.86 | 5853.65 | 03-APR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.117936E+09 | 5860.05 | 20-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.658455E+09 | 5911.57 | 27-NOV-07:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.168315E+10 | 5911.06 | 19-DEC-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.536648E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.168315E+10 | 5914.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.130913E+10 | 5753.78 | 09-JAN-07:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.746799E+09 | 5756.19 | 13-FEB-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.590432E+09 | 5746.03 | 07-MAR-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 35163226.16 | 5727.00 | 12-APR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 3621525.41 | 3339.44 | 05-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.203139E+09 | 5727.62 | 18-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.711642E+09 | 5747.25 | 27-NOV-06:14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.157888E+10 | 5754.23 | 26-DEC-07:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.517880E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.157888E+10 | 5756.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_TOP HEATING COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.665844E+10 | 16743.84 | 10-JAN-07:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.473217E+10 | 16221.61 | 17-FEB-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.380662E+10 | 12027.32 | 08-MAR-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.744852E+09 | 10036.02 | 08-APR-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.228628E+09 | 6794.33 | 06-MAY-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 4586157.48 | 1958.28 | 08-JUN-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 96471.72 | 4.63 | 10-JUL-13:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 287418.89 | 301.05 | 24-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 49929326.20 | 4615.80 | 21-SEP-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.872678E+09 | 7527.09 | 23-OCT-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.322530E+10 | 12475.71 | 29-NOV-07:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.647213E+10 | 13717.26 | 27-DEC-07:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.267957E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 96471.72 | 4.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.665844E+10 | 16743.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_TOP VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.270259E+10 | 20895.22 | 14-JAN-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.140689E+10 | 20901.66 | 01-FEB-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.999435E+09 | 20896.40 | 07-MAR-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 27954909.84 | 20706.09 | 03-APR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.245938E+09 | 20906.00 | 30-OCT-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.124577E+10 | 20920.97 | 24-NOV-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.326581E+10 | 20897.69 | 21-DEC-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.989438E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.326581E+10 | 20920.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.241167E+10 | 10049.03 | 30-JAN-06:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.161708E+10 | 10046.00 | 27-FEB-06:16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.155019E+10 | 10049.41 | 06-MAR-06:17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.231092E+09 | 10010.54 | 26-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 91994189.49 | 10017.39 | 15-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 1904611.30 | 3784.53 | 08-JUN-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 22998007.66 | 9999.84 | 20-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.667077E+09 | 10026.96 | 23-OCT-05:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.159915E+10 | 10046.89 | 13-NOV-06:14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.304336E+10 | 10047.81 | 05-DEC-06:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.112365E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.304336E+10 | 10049.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.206257E+10 | 6649.83 | 10-JAN-07:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.138343E+10 | 6636.62 | 13-FEB-07:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.115037E+10 | 6632.16 | 06-MAR-06:17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 88302175.68 | 6596.76 | 11-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 21732205.20 | 6601.83 | 04-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 7558250.90 | 6603.51 | 21-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.540268E+09 | 6633.11 | 23-OCT-05:14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.136046E+10 | 6637.97 | 20-NOV-07:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.238119E+10 | 6641.54 | 04-DEC-06:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.899587E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.238119E+10 | 6649.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.291394E+10 | 7228.35 | 10-JAN-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.194713E+10 | 7138.31 | 17-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.147120E+10 | 7129.70 | 17-MAR-06:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.188959E+09 | 7088.78 | 03-APR-05:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 29679121.95 | 7081.90 | 05-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 17349735.76 | 7081.43 | 21-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.639529E+09 | 7127.34 | 30-OCT-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.175850E+10 | 7130.36 | 13-NOV-07:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.323481E+10 | 7130.99 | 05-DEC-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.122011E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.323481E+10 | 7228.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.228650E+10 | 6913.17 | 17-JAN-06:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.152801E+10 | 6908.97 | 13-FEB-07:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.132882E+10 | 6899.56 | 06-MAR-06:25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.212593E+09 | 6877.27 | 26-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 78545902.53 | 6881.67 | 15-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 1319805.25 | 2317.26 | 08-JUN-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 316757.35 | 628.61 | 01-JUL-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 97731.21 | 437.74 | 24-AUG-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 36306353.90 | 6874.13 | 21-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.694248E+09 | 6893.69 | 30-OCT-05:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.156285E+10 | 6910.41 | 20-NOV-07:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.267514E+10 | 6906.88 | 18-DEC-06:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.104047E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 97731.21 | 437.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.267514E+10 | 6913.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_BOT COOLING COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.165716E+10 | 0.158759E+10 | 33968.14 | 30-APR-15:31 | 33968.14 | 0.00 |
May | 0.00 | 0.00 | 0.266743E+10 | 0.227714E+10 | 43730.43 | 22-MAY-15:00 | 43730.43 | 0.00 |
June | 0.00 | 0.00 | 0.910238E+10 | 0.754193E+10 | 62011.75 | 13-JUN-16:00 | 56670.86 | 0.00 |
July | 0.00 | 0.00 | 0.154463E+11 | 0.125732E+11 | 57482.29 | 21-JUL-16:00 | 57482.29 | 0.00 |
August | 0.00 | 0.00 | 0.198093E+11 | 0.156851E+11 | 56935.84 | 14-AUG-15:50 | 55807.50 | 0.00 |
September | 0.00 | 0.00 | 0.996732E+10 | 0.821777E+10 | 48888.34 | 13-SEP-15:20 | 44254.99 | 0.00 |
October | 0.00 | 0.00 | 0.367213E+09 | 0.352012E+09 | 11237.88 | 07-OCT-15:00 | 11237.88 | 0.00 |
November | 0.00 | 0.00 | 3627594.25 | 2532434.30 | 2726.22 | 24-NOV-12:00 | 1950.72 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.590207E+11 | 0.482373E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.198093E+11 | 0.156851E+11 | 62011.75 | 57482.29 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_MID COOLING COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.169940E+10 | 0.164012E+10 | 36018.95 | 30-APR-16:02 | 36018.95 | 0.00 |
May | 0.00 | 0.00 | 0.258085E+10 | 0.221394E+10 | 41431.84 | 22-MAY-15:00 | 41431.84 | 0.00 |
June | 0.00 | 0.00 | 0.859590E+10 | 0.713659E+10 | 58229.78 | 13-JUN-15:30 | 52882.15 | 0.00 |
July | 0.00 | 0.00 | 0.142948E+11 | 0.116285E+11 | 52739.87 | 21-JUL-15:40 | 52739.87 | 0.00 |
August | 0.00 | 0.00 | 0.179853E+11 | 0.142172E+11 | 52237.87 | 14-AUG-15:30 | 50526.38 | 0.00 |
September | 0.00 | 0.00 | 0.909981E+10 | 0.748338E+10 | 44202.81 | 13-SEP-14:50 | 40129.52 | 0.00 |
October | 0.00 | 0.00 | 0.316370E+09 | 0.303283E+09 | 10457.21 | 07-OCT-15:00 | 10457.21 | 0.00 |
November | 0.00 | 0.00 | 3121318.34 | 2149836.75 | 2325.31 | 24-NOV-12:00 | 1634.43 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.545755E+11 | 0.446252E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.179853E+11 | 0.142172E+11 | 58229.78 | 52882.15 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_TOP COOLING COIL
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 37783.32 | 33482.03 | 251.89 | 09-JAN-05:50 | 223.21 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.172034E+10 | 0.165004E+10 | 37281.89 | 30-APR-16:22 | 37281.89 | 0.00 |
May | 0.00 | 0.00 | 0.265047E+10 | 0.225245E+10 | 44638.13 | 22-MAY-15:00 | 44638.13 | 0.00 |
June | 0.00 | 0.00 | 0.889391E+10 | 0.735563E+10 | 67275.96 | 13-JUN-14:40 | 59428.32 | 0.00 |
July | 0.00 | 0.00 | 0.146668E+11 | 0.119150E+11 | 60941.63 | 21-JUL-15:50 | 60941.63 | 0.00 |
August | 0.00 | 0.00 | 0.177848E+11 | 0.139049E+11 | 56834.38 | 14-AUG-15:40 | 56834.38 | 0.00 |
September | 0.00 | 0.00 | 0.865673E+10 | 0.704163E+10 | 44509.68 | 13-SEP-15:00 | 40712.19 | 0.00 |
October | 0.00 | 0.00 | 0.287355E+09 | 0.271109E+09 | 10236.53 | 07-OCT-15:00 | 10236.53 | 0.00 |
November | 0.00 | 0.00 | 3243000.23 | 2206059.70 | 2428.47 | 24-NOV-12:00 | 1684.22 | 0.00 |
December | 0.00 | 0.00 | 110070.61 | 92625.08 | 290.37 | 18-DEC-05:20 | 237.98 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.546638E+11 | 0.443930E+11 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.177848E+11 | 0.139049E+11 | 67275.96 | 60941.63 | 0.00 |
Report: PlantLoopDemandReportMonthly
For: HEATSYS1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 16569.43 | 160998.41 | 30-JAN-06:11 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 11718.48 | 157538.42 | 23-FEB-07:01 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 8897.93 | 163949.87 | 21-MAR-06:01 |
April | 0.00 | 0.00 | 01-APR-00:10 | 1291.52 | 147580.33 | 03-APR-06:02 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 603.97 | 69065.12 | 05-MAY-06:03 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 172.91 | 12977.82 | 08-JUN-06:03 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 62.96 | 9589.99 | 20-JUL-06:05 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 57.53 | 11407.79 | 21-AUG-06:07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 202.57 | 55160.34 | 21-SEP-06:03 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 2483.82 | 140904.75 | 19-OCT-06:03 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 8489.50 | 159775.76 | 27-NOV-06:11 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 17439.39 | 153246.86 | 13-DEC-07:01 |
Annual Sum or Average | 0.00 | 5650.35 | ||||
Minimum of Months | 0.00 | 0.00 | 57.53 | 9589.99 | ||
Maximum of Months | 0.00 | 0.00 | 17439.39 | 163949.87 |
Report: PlantLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 1742.56 | 6368.03 | 31-JAN-12:20 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 1764.91 | 6378.10 | 14-FEB-12:50 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 1875.11 | 6367.76 | 01-MAR-12:15 |
April | 0.00 | 0.00 | 01-APR-00:10 | 1710.72 | 6273.14 | 03-APR-11:50 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 1729.43 | 6135.51 | 01-MAY-11:15 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 1728.43 | 5961.12 | 01-JUN-11:30 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 1542.87 | 5806.87 | 03-JUL-11:30 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 1693.70 | 5727.73 | 31-AUG-11:20 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 1586.93 | 5807.33 | 29-SEP-12:00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 1619.28 | 5961.80 | 31-OCT-12:00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 1691.40 | 6130.75 | 30-NOV-12:20 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 1662.71 | 6273.73 | 29-DEC-12:50 |
Annual Sum or Average | 0.00 | 1695.28 | ||||
Minimum of Months | 0.00 | 0.00 | 1542.87 | 5727.73 | ||
Maximum of Months | 0.00 | 0.00 | 1875.11 | 6378.10 |
Report: FanReportMonthly
For: PACU_VAV_BOT FAN
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.136115E+10 | 0.27 | 2588.72 | 02-JAN-07:01 | 0.78 |
February | 0.127182E+10 | 0.28 | 1612.33 | 01-FEB-07:02 | 0.61 |
March | 0.154085E+10 | 0.30 | 1777.42 | 30-MAR-07:06 | 0.64 |
April | 0.220518E+10 | 0.33 | 5454.04 | 28-APR-15:30 | 1.20 |
May | 0.266941E+10 | 0.36 | 5510.90 | 22-MAY-06:03 | 1.20 |
June | 0.334958E+10 | 0.41 | 7573.37 | 13-JUN-16:00 | 1.46 |
July | 0.373015E+10 | 0.42 | 7453.59 | 21-JUL-16:00 | 1.45 |
August | 0.403260E+10 | 0.45 | 7562.61 | 14-AUG-15:30 | 1.46 |
September | 0.328215E+10 | 0.40 | 7120.67 | 12-SEP-15:20 | 1.41 |
October | 0.194456E+10 | 0.31 | 4988.20 | 04-OCT-06:02 | 1.14 |
November | 0.141883E+10 | 0.28 | 2027.11 | 10-NOV-08:04 | 0.68 |
December | 0.131367E+10 | 0.27 | 1612.33 | 01-DEC-06:11 | 0.61 |
Annual Sum or Average | 0.281199E+11 | 0.34 | |||
Minimum of Months | 0.127182E+10 | 0.27 | 1612.33 | 0.61 | |
Maximum of Months | 0.403260E+10 | 0.45 | 7573.37 | 1.46 |
Report: FanReportMonthly
For: PACU_VAV_MID FAN
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.133208E+10 | 0.27 | 2710.43 | 02-JAN-06:02 | 0.83 |
February | 0.122661E+10 | 0.28 | 2710.43 | 06-FEB-07:02 | 0.83 |
March | 0.139872E+10 | 0.29 | 2710.43 | 06-MAR-07:01 | 0.83 |
April | 0.195903E+10 | 0.33 | 5797.02 | 28-APR-15:20 | 1.30 |
May | 0.228959E+10 | 0.35 | 5456.64 | 23-MAY-15:20 | 1.25 |
June | 0.291637E+10 | 0.40 | 7131.76 | 13-JUN-15:30 | 1.47 |
July | 0.325324E+10 | 0.41 | 6751.30 | 21-JUL-15:40 | 1.42 |
August | 0.347632E+10 | 0.44 | 6745.89 | 14-AUG-15:30 | 1.42 |
September | 0.270919E+10 | 0.38 | 6448.35 | 12-SEP-15:20 | 1.38 |
October | 0.157345E+10 | 0.29 | 3503.71 | 03-OCT-14:40 | 0.96 |
November | 0.127710E+10 | 0.27 | 2710.43 | 20-NOV-07:01 | 0.83 |
December | 0.129349E+10 | 0.27 | 2710.43 | 04-DEC-07:01 | 0.83 |
Annual Sum or Average | 0.247052E+11 | 0.33 | |||
Minimum of Months | 0.122661E+10 | 0.27 | 2710.43 | 0.83 | |
Maximum of Months | 0.347632E+10 | 0.44 | 7131.76 | 1.47 |
Report: FanReportMonthly
For: PACU_VAV_TOP FAN
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.143067E+10 | 0.28 | 2570.74 | 02-JAN-05:01 | 0.76 |
February | 0.125663E+10 | 0.28 | 2570.74 | 01-FEB-07:02 | 0.76 |
March | 0.144184E+10 | 0.29 | 2570.74 | 01-MAR-07:02 | 0.76 |
April | 0.181542E+10 | 0.31 | 5622.62 | 28-APR-15:20 | 1.19 |
May | 0.209913E+10 | 0.33 | 5498.36 | 22-MAY-15:20 | 1.17 |
June | 0.265377E+10 | 0.37 | 7402.63 | 13-JUN-15:40 | 1.41 |
July | 0.294764E+10 | 0.37 | 6954.09 | 21-JUL-15:40 | 1.35 |
August | 0.305133E+10 | 0.39 | 6595.28 | 14-AUG-15:30 | 1.31 |
September | 0.230126E+10 | 0.34 | 5840.46 | 12-SEP-15:20 | 1.21 |
October | 0.148292E+10 | 0.28 | 2662.93 | 03-OCT-14:50 | 0.77 |
November | 0.131432E+10 | 0.27 | 2570.74 | 02-NOV-06:03 | 0.76 |
December | 0.137279E+10 | 0.27 | 2570.74 | 01-DEC-07:01 | 0.76 |
Annual Sum or Average | 0.231677E+11 | 0.32 | |||
Minimum of Months | 0.125663E+10 | 0.27 | 2570.74 | 0.76 | |
Maximum of Months | 0.305133E+10 | 0.39 | 7402.63 | 1.41 |
Report: PumpReportMonthly
For: HEATSYS1 PUMP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.276963E+09 | 0.249267E+09 | 558.98 | 10-JAN-07:25 | 503.09 | 503.09 | 41.34 | 1.75 |
February | 0.182409E+09 | 0.164168E+09 | 536.86 | 17-FEB-07:12 | 483.17 | 483.17 | 40.51 | 1.61 |
March | 0.154761E+09 | 0.139285E+09 | 523.10 | 13-MAR-06:01 | 470.79 | 470.79 | 35.58 | 1.50 |
April | 25091682.97 | 22582514.67 | 504.82 | 01-APR-06:03 | 454.34 | 454.34 | 33.29 | 1.30 |
May | 14792824.79 | 13313542.31 | 354.36 | 05-MAY-06:03 | 318.92 | 318.92 | 28.74 | 0.53 |
June | 5090780.87 | 4581702.79 | 140.17 | 08-JUN-06:03 | 126.15 | 126.15 | 40.48 | 0.16 |
July | 1812280.40 | 1631052.36 | 83.81 | 06-JUL-06:05 | 75.43 | 75.43 | 43.53 | 0.09 |
August | 1533268.84 | 1379941.95 | 85.10 | 24-AUG-06:10 | 76.59 | 76.59 | 35.57 | 0.09 |
September | 5060162.93 | 4554146.63 | 347.25 | 21-SEP-06:03 | 312.53 | 312.53 | 34.15 | 0.51 |
October | 46212249.28 | 41591024.36 | 505.25 | 23-OCT-06:03 | 454.72 | 454.72 | 35.52 | 1.30 |
November | 0.141757E+09 | 0.127581E+09 | 533.50 | 29-NOV-07:01 | 480.15 | 480.15 | 36.73 | 1.59 |
December | 0.289358E+09 | 0.260422E+09 | 539.95 | 27-DEC-07:01 | 485.96 | 485.96 | 39.47 | 1.64 |
Annual Sum or Average | 0.114484E+10 | 0.103036E+10 | ||||||
Minimum of Months | 1533268.84 | 1379941.95 | 83.81 | 75.43 | 75.43 | 28.74 | 0.09 | |
Maximum of Months | 0.289358E+09 | 0.260422E+09 | 558.98 | 503.09 | 503.09 | 43.53 | 1.75 |
Report: PumpReportMonthly
For: SWHSYS1 PUMP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 12379742.02 | 3713922.60 | 6.85 | 01-JAN-06:10 | 2.06 | 2.06 | 58.09 | 0.05 |
February | 11196021.66 | 3358806.50 | 6.85 | 01-FEB-06:03 | 2.06 | 2.06 | 56.85 | 0.05 |
March | 12675672.10 | 3802701.63 | 6.85 | 01-MAR-06:03 | 2.06 | 2.06 | 56.85 | 0.05 |
April | 11960507.72 | 3588152.32 | 6.85 | 01-APR-05:05 | 2.06 | 2.06 | 56.81 | 0.05 |
May | 12527707.06 | 3758312.12 | 6.85 | 01-MAY-05:03 | 2.06 | 2.06 | 57.23 | 0.05 |
June | 12231776.97 | 3669533.09 | 6.85 | 01-JUN-05:03 | 2.06 | 2.06 | 57.13 | 0.05 |
July | 12256437.81 | 3676931.34 | 6.85 | 01-JUL-05:05 | 2.06 | 2.06 | 57.05 | 0.05 |
August | 12675672.10 | 3802701.63 | 6.85 | 01-AUG-05:03 | 2.06 | 2.06 | 57.18 | 0.05 |
September | 11960507.72 | 3588152.32 | 6.85 | 01-SEP-05:03 | 2.06 | 2.06 | 57.17 | 0.05 |
October | 12379742.02 | 3713922.60 | 6.85 | 01-OCT-05:10 | 2.06 | 2.06 | 58.10 | 0.05 |
November | 12059151.09 | 3617745.33 | 6.85 | 01-NOV-05:03 | 2.06 | 2.06 | 57.05 | 0.05 |
December | 12256437.81 | 3676931.34 | 6.85 | 01-DEC-06:03 | 2.06 | 2.06 | 56.97 | 0.05 |
Annual Sum or Average | 0.146559E+09 | 43967812.83 | ||||||
Minimum of Months | 11196021.66 | 3358806.50 | 6.85 | 2.06 | 2.06 | 56.81 | 0.05 | |
Maximum of Months | 12675672.10 | 3802701.63 | 6.85 | 2.06 | 2.06 | 58.10 | 0.05 |
Report: CondLoopDemandReportMonthly
For: HEATSYS1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 38.98 | 38.98 | 16569.43 | 160998.41 | 30-JAN-06:11 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 27.00 | 27.00 | 11718.48 | 157538.42 | 23-FEB-07:01 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 27.98 | 27.98 | 8897.93 | 163949.87 | 21-MAR-06:01 |
April | 0.00 | 0.00 | 01-APR-00:10 | 24.84 | 24.84 | 1291.52 | 147580.33 | 03-APR-06:02 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 39.93 | 39.93 | 603.97 | 69065.12 | 05-MAY-06:03 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 43.04 | 43.04 | 172.91 | 12977.82 | 08-JUN-06:03 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 36.61 | 36.61 | 62.96 | 9589.99 | 20-JUL-06:05 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 38.99 | 38.99 | 57.53 | 11407.79 | 21-AUG-06:07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 36.89 | 36.89 | 202.57 | 55160.34 | 21-SEP-06:03 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 35.03 | 35.03 | 2483.82 | 140904.75 | 19-OCT-06:03 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 23.67 | 23.67 | 8489.50 | 159775.76 | 27-NOV-06:11 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 29.20 | 29.20 | 17439.39 | 153246.86 | 13-DEC-07:01 |
Annual Sum or Average | 0.00 | 5650.35 | ||||||
Minimum of Months | 0.00 | 0.00 | 23.67 | 23.67 | 57.53 | 9589.99 | ||
Maximum of Months | 0.00 | 0.00 | 43.04 | 43.04 | 17439.39 | 163949.87 |
Report: CondLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 58.09 | 58.09 | 1742.56 | 6368.03 | 31-JAN-12:20 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 57.56 | 57.56 | 1764.91 | 6378.10 | 14-FEB-12:50 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 57.56 | 57.56 | 1875.11 | 6367.76 | 01-MAR-12:15 |
April | 0.00 | 0.00 | 01-APR-00:10 | 57.59 | 57.59 | 1710.72 | 6273.14 | 03-APR-11:50 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 58.14 | 58.14 | 1729.43 | 6135.51 | 01-MAY-11:15 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 57.72 | 57.72 | 1728.43 | 5961.12 | 01-JUN-11:30 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 57.78 | 57.78 | 1542.87 | 5806.87 | 03-JUL-11:30 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 57.81 | 57.81 | 1693.70 | 5727.73 | 31-AUG-11:20 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 57.81 | 57.81 | 1586.93 | 5807.33 | 29-SEP-12:00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 56.87 | 56.87 | 1619.28 | 5961.80 | 31-OCT-12:00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 57.72 | 57.72 | 1691.40 | 6130.75 | 30-NOV-12:20 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 57.65 | 57.65 | 1662.71 | 6273.73 | 29-DEC-12:50 |
Annual Sum or Average | 0.00 | 1695.28 | ||||||
Minimum of Months | 0.00 | 0.00 | 56.87 | 56.87 | 1542.87 | 5727.73 | ||
Maximum of Months | 0.00 | 0.00 | 58.14 | 58.14 | 1875.11 | 6378.10 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_BOT
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.135760E+11 | 0.00 | 0.00 | 0.136115E+10 | 0.00 | 0.00 |
February | 0.853163E+10 | 0.00 | 0.00 | 0.127182E+10 | 0.00 | 0.00 |
March | 0.795147E+10 | 0.00 | 0.00 | 0.154085E+10 | 0.00 | 0.00 |
April | 0.131651E+10 | 0.00 | 0.00 | 0.260191E+10 | 0.00 | 0.00 |
May | 0.108999E+10 | 0.00 | 0.00 | 0.327884E+10 | 0.00 | 0.00 |
June | 0.448484E+09 | 0.00 | 0.00 | 0.538349E+10 | 0.00 | 0.00 |
July | 0.168639E+09 | 0.00 | 0.00 | 0.724559E+10 | 0.00 | 0.00 |
August | 0.156192E+09 | 0.00 | 0.00 | 0.852595E+10 | 0.00 | 0.00 |
September | 0.382626E+09 | 0.00 | 0.00 | 0.553466E+10 | 0.00 | 0.00 |
October | 0.188974E+10 | 0.00 | 0.00 | 0.203856E+10 | 0.00 | 0.00 |
November | 0.596170E+10 | 0.00 | 0.00 | 0.141980E+10 | 0.00 | 0.00 |
December | 0.131348E+11 | 0.00 | 0.00 | 0.131367E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.546078E+11 | 0.00 | 0.00 | 0.415163E+11 | 0.00 | 0.00 |
Minimum of Months | 0.156192E+09 | 0.00 | 0.00 | 0.127182E+10 | 0.00 | 0.00 |
Maximum of Months | 0.135760E+11 | 0.00 | 0.00 | 0.852595E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_MID
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.120781E+11 | 0.00 | 0.00 | 0.133208E+10 | 0.00 | 0.00 |
February | 0.740230E+10 | 0.00 | 0.00 | 0.122661E+10 | 0.00 | 0.00 |
March | 0.574518E+10 | 0.00 | 0.00 | 0.139872E+10 | 0.00 | 0.00 |
April | 0.556063E+09 | 0.00 | 0.00 | 0.236121E+10 | 0.00 | 0.00 |
May | 90730772.64 | 0.00 | 0.00 | 0.287716E+10 | 0.00 | 0.00 |
June | 425998.71 | 0.00 | 0.00 | 0.483653E+10 | 0.00 | 0.00 |
July | 158447.18 | 0.00 | 0.00 | 0.650776E+10 | 0.00 | 0.00 |
August | 174650.75 | 0.00 | 0.00 | 0.756138E+10 | 0.00 | 0.00 |
September | 14454088.83 | 0.00 | 0.00 | 0.476828E+10 | 0.00 | 0.00 |
October | 0.115915E+10 | 0.00 | 0.00 | 0.165471E+10 | 0.00 | 0.00 |
November | 0.544328E+10 | 0.00 | 0.00 | 0.127793E+10 | 0.00 | 0.00 |
December | 0.128165E+11 | 0.00 | 0.00 | 0.129349E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.453065E+11 | 0.00 | 0.00 | 0.370959E+11 | 0.00 | 0.00 |
Minimum of Months | 158447.18 | 0.00 | 0.00 | 0.122661E+10 | 0.00 | 0.00 |
Maximum of Months | 0.128165E+11 | 0.00 | 0.00 | 0.756138E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_TOP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.190357E+11 | 0.00 | 0.00 | 0.143068E+10 | 0.00 | 0.00 |
February | 0.126147E+11 | 0.00 | 0.00 | 0.125663E+10 | 0.00 | 0.00 |
March | 0.103066E+11 | 0.00 | 0.00 | 0.144184E+10 | 0.00 | 0.00 |
April | 0.149375E+10 | 0.00 | 0.00 | 0.222577E+10 | 0.00 | 0.00 |
May | 0.450580E+09 | 0.00 | 0.00 | 0.270729E+10 | 0.00 | 0.00 |
June | 7810574.02 | 0.00 | 0.00 | 0.465103E+10 | 0.00 | 0.00 |
July | 413229.07 | 0.00 | 0.00 | 0.631159E+10 | 0.00 | 0.00 |
August | 385150.10 | 0.00 | 0.00 | 0.713765E+10 | 0.00 | 0.00 |
September | 0.134142E+09 | 0.00 | 0.00 | 0.428410E+10 | 0.00 | 0.00 |
October | 0.365974E+10 | 0.00 | 0.00 | 0.155739E+10 | 0.00 | 0.00 |
November | 0.107520E+11 | 0.00 | 0.00 | 0.131519E+10 | 0.00 | 0.00 |
December | 0.210724E+11 | 0.00 | 0.00 | 0.137282E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.795283E+11 | 0.00 | 0.00 | 0.356920E+11 | 0.00 | 0.00 |
Minimum of Months | 385150.10 | 0.00 | 0.00 | 0.125663E+10 | 0.00 | 0.00 |
Maximum of Months | 0.210724E+11 | 0.00 | 0.00 | 0.713765E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_BOT
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.136115E+10 | 0.00 | 0.135760E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.127182E+10 | 0.00 | 0.853163E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.154085E+10 | 0.00 | 0.795147E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.220518E+10 | 0.165716E+10 | 0.131651E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.266941E+10 | 0.266743E+10 | 0.108999E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.334958E+10 | 0.910238E+10 | 0.448484E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.373015E+10 | 0.154463E+11 | 0.168639E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.403260E+10 | 0.198093E+11 | 0.156192E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.328215E+10 | 0.996732E+10 | 0.382626E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.194456E+10 | 0.367213E+09 | 0.188974E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.141883E+10 | 3627594.25 | 0.596170E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.131367E+10 | 0.00 | 0.131348E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.281199E+11 | 0.590207E+11 | 0.546078E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.127182E+10 | 0.00 | 0.156192E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.403260E+10 | 0.198093E+11 | 0.135760E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_MID
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.133208E+10 | 0.00 | 0.120781E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.122661E+10 | 0.00 | 0.740230E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.139872E+10 | 0.00 | 0.574518E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.195903E+10 | 0.169940E+10 | 0.556063E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.228959E+10 | 0.258085E+10 | 90730772.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.291637E+10 | 0.859590E+10 | 425998.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.325324E+10 | 0.142948E+11 | 158447.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.347632E+10 | 0.179853E+11 | 174650.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.270919E+10 | 0.909981E+10 | 14454088.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.157345E+10 | 0.316370E+09 | 0.115915E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.127710E+10 | 3121318.34 | 0.544328E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.129349E+10 | 0.00 | 0.128165E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.247052E+11 | 0.545755E+11 | 0.453065E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.122661E+10 | 0.00 | 158447.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.347632E+10 | 0.179853E+11 | 0.128165E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_TOP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.143067E+10 | 37783.32 | 0.190357E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.125663E+10 | 0.00 | 0.126147E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.144184E+10 | 0.00 | 0.103066E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.181542E+10 | 0.172034E+10 | 0.149375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.209913E+10 | 0.265047E+10 | 0.450580E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.265377E+10 | 0.889391E+10 | 7810574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.294764E+10 | 0.146668E+11 | 413229.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.305133E+10 | 0.177848E+11 | 385150.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.230126E+10 | 0.865673E+10 | 0.134142E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.148292E+10 | 0.287355E+09 | 0.365974E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.131432E+10 | 3243000.23 | 0.107520E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.137279E+10 | 110070.61 | 0.210724E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.231677E+11 | 0.546638E+11 | 0.795283E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.125663E+10 | 0.00 | 385150.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.305133E+10 | 0.177848E+11 | 0.210724E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_BOT
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.136115E+10 | 0.135760E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.127182E+10 | 0.853163E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.154085E+10 | 0.795147E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.220518E+10 | 0.131651E+10 | 0.00 | 0.00 | 0.396729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.266941E+10 | 0.108999E+10 | 0.00 | 0.00 | 0.609433E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.334958E+10 | 0.448484E+09 | 0.00 | 0.00 | 0.203391E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.373015E+10 | 0.168639E+09 | 0.00 | 0.00 | 0.351545E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.403260E+10 | 0.156192E+09 | 0.00 | 0.00 | 0.449336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.328215E+10 | 0.382626E+09 | 0.00 | 0.00 | 0.225251E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.194456E+10 | 0.188974E+10 | 0.00 | 0.00 | 93995753.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.141883E+10 | 0.596170E+10 | 0.00 | 0.00 | 967521.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.131367E+10 | 0.131348E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.281199E+11 | 0.546078E+11 | 0.00 | 0.00 | 0.133963E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.127182E+10 | 0.156192E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.403260E+10 | 0.135760E+11 | 0.00 | 0.00 | 0.449336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_MID
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.133208E+10 | 0.120781E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.122661E+10 | 0.740230E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.139872E+10 | 0.574518E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.195903E+10 | 0.556063E+09 | 0.00 | 0.00 | 0.402180E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.228959E+10 | 90730772.64 | 0.00 | 0.00 | 0.587576E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.291637E+10 | 425998.71 | 0.00 | 0.00 | 0.192017E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.325324E+10 | 158447.18 | 0.00 | 0.00 | 0.325453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.347632E+10 | 174650.75 | 0.00 | 0.00 | 0.408506E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.270919E+10 | 14454088.83 | 0.00 | 0.00 | 0.205909E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.157345E+10 | 0.115915E+10 | 0.00 | 0.00 | 81260129.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.127710E+10 | 0.544328E+10 | 0.00 | 0.00 | 834067.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.129349E+10 | 0.128165E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.247052E+11 | 0.453065E+11 | 0.00 | 0.00 | 0.123907E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.122661E+10 | 158447.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.347632E+10 | 0.128165E+11 | 0.00 | 0.00 | 0.408506E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_TOP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.143067E+10 | 0.190357E+11 | 0.00 | 0.00 | 10264.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.125663E+10 | 0.126147E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.144184E+10 | 0.103066E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.181542E+10 | 0.149375E+10 | 0.00 | 0.00 | 0.410350E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.209913E+10 | 0.450580E+09 | 0.00 | 0.00 | 0.608163E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.265377E+10 | 7810574.02 | 0.00 | 0.00 | 0.199726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.294764E+10 | 413229.07 | 0.00 | 0.00 | 0.336395E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.305133E+10 | 385150.10 | 0.00 | 0.00 | 0.408632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.230126E+10 | 0.134142E+09 | 0.00 | 0.00 | 0.198284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.148292E+10 | 0.365974E+10 | 0.00 | 0.00 | 74470520.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.131432E+10 | 0.107520E+11 | 0.00 | 0.00 | 867632.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.137279E+10 | 0.210724E+11 | 0.00 | 0.00 | 29894.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.231677E+11 | 0.795283E+11 | 0.00 | 0.00 | 0.125243E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.125663E+10 | 385150.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.305133E+10 | 0.210724E+11 | 0.00 | 0.00 | 0.408632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_BOTTOM
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.684774E+10 | 0.00 | 0.00 | 10912699.61 | 0.00 | 8453628.65 | 0.751035E+10 | 0.00 | 0.31 |
February | 0.457997E+10 | 0.00 | 0.00 | 15770796.75 | 0.00 | 0.00 | 0.869979E+10 | 0.00 | 0.32 |
March | 0.427923E+10 | 0.00 | 0.00 | 19000646.22 | 0.00 | 0.00 | 0.113935E+11 | 0.00 | 0.36 |
April | 0.992705E+09 | 233586.58 | 0.00 | 38163398.26 | 0.00 | 0.00 | 0.198315E+11 | 0.00 | 0.66 |
May | 0.101120E+10 | 0.00 | 0.00 | 43632499.47 | 0.00 | 0.00 | 0.229894E+11 | 0.00 | 0.76 |
June | 0.785481E+09 | 16460570.36 | 0.00 | 46412914.83 | 32308205.31 | 0.00 | 0.235812E+11 | 0.00 | 1.05 |
July | 0.100036E+10 | 16680200.88 | 0.00 | 44319377.78 | 2900082.52 | 0.00 | 0.200795E+11 | 0.00 | 1.09 |
August | 0.103839E+10 | 0.00 | 0.00 | 48241754.27 | 0.00 | 0.00 | 0.195738E+11 | 0.00 | 1.23 |
September | 0.100139E+10 | 0.00 | 0.00 | 42484352.26 | 154661.74 | 0.00 | 0.205651E+11 | 0.00 | 1.03 |
October | 0.111450E+10 | 0.00 | 0.00 | 31207504.94 | 0.00 | 0.00 | 0.177848E+11 | 0.00 | 0.57 |
November | 0.289020E+10 | 0.00 | 0.00 | 19239041.44 | 0.00 | 0.00 | 0.115707E+11 | 0.00 | 0.36 |
December | 0.655662E+10 | 0.00 | 0.00 | 10088283.88 | 0.00 | 0.00 | 0.687898E+10 | 0.00 | 0.29 |
Annual Sum or Average | 0.320978E+11 | 33374357.82 | 0.00 | 0.369473E+09 | 35362949.56 | 8453628.65 | 0.190459E+12 | 0.00 | 0.67 |
Minimum of Months | 0.785481E+09 | 0.00 | 0.00 | 10088283.88 | 0.00 | 0.00 | 0.687898E+10 | 0.00 | 0.29 |
Maximum of Months | 0.684774E+10 | 16680200.88 | 0.00 | 48241754.27 | 32308205.31 | 8453628.65 | 0.235812E+11 | 0.00 | 1.23 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_MID
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.121722E+11 | 0.00 | 0.00 | 58120.20 | 0.00 | 0.278715E+09 | 0.155375E+09 | 0.00 | 0.27 |
February | 0.110183E+11 | 0.00 | 0.00 | 54809.90 | 0.00 | 11133990.46 | 0.233267E+09 | 0.00 | 0.28 |
March | 0.123615E+11 | 0.00 | 0.00 | 146248.22 | 0.00 | 5940852.42 | 0.507650E+09 | 0.00 | 0.30 |
April | 0.508680E+10 | 954067.20 | 0.00 | 12564380.81 | 0.00 | 0.00 | 0.864296E+10 | 0.00 | 0.44 |
May | 0.451162E+10 | 0.00 | 0.00 | 18941093.45 | 0.00 | 0.00 | 0.114654E+11 | 0.00 | 0.51 |
June | 0.240906E+10 | 13045062.10 | 0.00 | 24948106.97 | 30702076.48 | 0.00 | 0.139479E+11 | 0.00 | 0.71 |
July | 0.238214E+10 | 15680473.18 | 0.00 | 24873212.68 | 4081115.98 | 0.00 | 0.120005E+11 | 0.00 | 0.75 |
August | 0.203752E+10 | 0.00 | 0.00 | 26294140.24 | 0.00 | 0.00 | 0.117289E+11 | 0.00 | 0.83 |
September | 0.337411E+10 | 0.00 | 0.00 | 18812296.85 | 532206.57 | 0.00 | 0.105708E+11 | 0.00 | 0.68 |
October | 0.758785E+10 | 0.00 | 0.00 | 5627471.08 | 0.00 | 0.00 | 0.470787E+10 | 0.00 | 0.38 |
November | 0.104384E+11 | 0.00 | 0.00 | 258722.55 | 0.00 | 11355901.84 | 0.738128E+09 | 0.00 | 0.29 |
December | 0.118655E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.127791E+09 | 0.00 | 0.00 | 0.27 |
Annual Sum or Average | 0.852450E+11 | 29679602.48 | 0.00 | 0.132579E+09 | 35315399.03 | 0.434936E+09 | 0.746988E+11 | 0.00 | 0.48 |
Minimum of Months | 0.203752E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.27 |
Maximum of Months | 0.123615E+11 | 15680473.18 | 0.00 | 26294140.24 | 30702076.48 | 0.278715E+09 | 0.139479E+11 | 0.00 | 0.83 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_TOP
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.106274E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.113554E+10 | 0.00 | 0.00 | 0.27 |
February | 0.100593E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.503867E+09 | 0.00 | 0.00 | 0.27 |
March | 0.117456E+11 | 0.00 | 0.00 | 1557.81 | 0.00 | 0.372685E+09 | 19636704.43 | 0.00 | 0.30 |
April | 0.693671E+10 | 2044274.55 | 0.00 | 8062962.66 | 1013537.42 | 4408934.84 | 0.634267E+10 | 0.00 | 0.42 |
May | 0.609089E+10 | 0.00 | 0.00 | 13558444.97 | 0.00 | 0.00 | 0.912466E+10 | 0.00 | 0.49 |
June | 0.367772E+10 | 6024227.58 | 0.00 | 21373701.47 | 25028442.12 | 0.00 | 0.122439E+11 | 0.00 | 0.69 |
July | 0.329100E+10 | 10950713.30 | 0.00 | 21237936.79 | 6835054.23 | 0.00 | 0.108827E+11 | 0.00 | 0.73 |
August | 0.318170E+10 | 0.00 | 0.00 | 20695376.85 | 0.00 | 0.00 | 0.101309E+11 | 0.00 | 0.80 |
September | 0.478299E+10 | 0.00 | 0.00 | 12991739.08 | 0.00 | 0.00 | 0.786411E+10 | 0.00 | 0.62 |
October | 0.908733E+10 | 0.00 | 0.00 | 1907341.21 | 0.00 | 73117049.84 | 0.199950E+10 | 0.00 | 0.36 |
November | 0.994529E+10 | 0.00 | 0.00 | 5979.94 | 0.00 | 0.326386E+09 | 52477143.81 | 0.00 | 0.28 |
December | 0.959160E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149368E+10 | 0.00 | 0.00 | 0.26 |
Annual Sum or Average | 0.890175E+11 | 19019215.43 | 0.00 | 99835040.79 | 32877033.77 | 0.390968E+10 | 0.586605E+11 | 0.00 | 0.46 |
Minimum of Months | 0.318170E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.26 |
Maximum of Months | 0.117456E+11 | 10950713.30 | 0.00 | 21373701.47 | 25028442.12 | 0.149368E+10 | 0.122439E+11 | 0.00 | 0.80 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.695139E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.183682E+10 | 0.00 | 0.00 | 0.27 |
February | 0.982576E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.127143E+10 | 0.00 | 0.00 | 0.27 |
March | 0.169857E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.877058E+09 | 0.00 | 0.00 | 0.30 |
April | 0.175113E+10 | 0.00 | 0.00 | 1099359.01 | 645403.46 | 0.108090E+09 | 0.896844E+09 | 0.00 | 0.42 |
May | 0.178808E+10 | 0.00 | 0.00 | 2138890.15 | 0.00 | 9778761.30 | 0.139645E+10 | 0.00 | 0.50 |
June | 0.935068E+09 | 2067413.76 | 0.00 | 4811073.07 | 5282680.30 | 0.00 | 0.261894E+10 | 0.00 | 0.77 |
July | 0.788491E+09 | 3877079.10 | 0.00 | 5063909.79 | 466525.79 | 0.00 | 0.249302E+10 | 0.00 | 0.83 |
August | 0.886389E+09 | 0.00 | 0.00 | 4453521.35 | 0.00 | 0.00 | 0.205713E+10 | 0.00 | 0.85 |
September | 0.145092E+10 | 0.00 | 0.00 | 1935797.90 | 0.00 | 5699259.74 | 0.111611E+10 | 0.00 | 0.61 |
October | 0.181803E+10 | 0.00 | 0.00 | 110915.05 | 0.00 | 0.341215E+09 | 0.156131E+09 | 0.00 | 0.35 |
November | 0.115212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104772E+10 | 0.00 | 0.00 | 0.28 |
December | 0.541815E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.184508E+10 | 0.00 | 0.00 | 0.27 |
Annual Sum or Average | 0.144883E+11 | 5944492.86 | 0.00 | 19613466.31 | 6394609.55 | 0.734290E+10 | 0.107346E+11 | 0.00 | 0.48 |
Minimum of Months | 0.541815E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.27 |
Maximum of Months | 0.181803E+10 | 3877079.10 | 0.00 | 5063909.79 | 5282680.30 | 0.184508E+10 | 0.261894E+10 | 0.00 | 0.85 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.921061E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148852E+10 | 0.00 | 0.00 | 0.41 |
February | 0.115226E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.991724E+09 | 0.00 | 0.00 | 0.41 |
March | 0.172559E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.731639E+09 | 0.00 | 0.00 | 0.45 |
April | 0.106329E+10 | 1962505.86 | 0.00 | 3764811.36 | 0.00 | 36328100.53 | 0.223479E+10 | 0.00 | 0.82 |
May | 0.123423E+10 | 0.00 | 0.00 | 4272251.98 | 0.00 | 8327984.99 | 0.249353E+10 | 0.00 | 0.93 |
June | 0.827528E+09 | 1469024.16 | 0.00 | 5985759.72 | 5044975.17 | 0.00 | 0.308964E+10 | 0.00 | 1.34 |
July | 0.655400E+09 | 10912339.80 | 0.00 | 6581522.64 | 445533.50 | 0.00 | 0.293209E+10 | 0.00 | 1.42 |
August | 0.702795E+09 | 0.00 | 0.00 | 6375879.31 | 0.00 | 0.00 | 0.279370E+10 | 0.00 | 1.58 |
September | 0.102740E+10 | 0.00 | 0.00 | 3927180.77 | 0.00 | 3670260.24 | 0.205926E+10 | 0.00 | 1.17 |
October | 0.155863E+10 | 0.00 | 0.00 | 693640.30 | 0.00 | 0.278965E+09 | 0.455790E+09 | 0.00 | 0.55 |
November | 0.124548E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.850536E+09 | 0.00 | 0.00 | 0.43 |
December | 0.734326E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.153953E+10 | 0.00 | 0.00 | 0.40 |
Annual Sum or Average | 0.128480E+11 | 14343869.82 | 0.00 | 31601046.07 | 5490508.67 | 0.592924E+10 | 0.160588E+11 | 0.00 | 0.83 |
Minimum of Months | 0.655400E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.40 |
Maximum of Months | 0.172559E+10 | 10912339.80 | 0.00 | 6581522.64 | 5044975.17 | 0.153953E+10 | 0.308964E+10 | 0.00 | 1.58 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.159497E+10 | 0.00 | 0.00 | 1121407.56 | 0.00 | 0.160150E+10 | 0.589391E+09 | 0.00 | 0.41 |
February | 0.164039E+10 | 0.00 | 0.00 | 1583358.59 | 0.00 | 0.106756E+10 | 0.849754E+09 | 0.00 | 0.43 |
March | 0.251552E+10 | 0.00 | 0.00 | 314762.97 | 0.00 | 0.959033E+09 | 0.236017E+09 | 0.00 | 0.43 |
April | 0.153020E+10 | 0.00 | 0.00 | 8115039.28 | 923347.57 | 0.131337E+09 | 0.446113E+10 | 0.00 | 0.95 |
May | 0.212189E+10 | 0.00 | 0.00 | 6322723.47 | 0.00 | 37926438.66 | 0.364213E+10 | 0.00 | 0.91 |
June | 0.153634E+10 | 2783772.52 | 0.00 | 7333201.09 | 7557675.69 | 487306.57 | 0.394452E+10 | 0.00 | 1.19 |
July | 0.117865E+10 | 2573281.72 | 0.00 | 8744702.71 | 3769288.07 | 0.00 | 0.402853E+10 | 0.00 | 1.33 |
August | 0.112421E+10 | 0.00 | 0.00 | 10562811.06 | 0.00 | 0.00 | 0.446421E+10 | 0.00 | 1.65 |
September | 0.138669E+10 | 0.00 | 0.00 | 9753850.87 | 0.00 | 6714705.66 | 0.472662E+10 | 0.00 | 1.52 |
October | 0.190683E+10 | 0.00 | 0.00 | 4128965.82 | 0.00 | 0.339709E+09 | 0.255225E+10 | 0.00 | 0.75 |
November | 0.184651E+10 | 0.00 | 0.00 | 1012916.94 | 0.00 | 0.966514E+09 | 0.501766E+09 | 0.00 | 0.43 |
December | 0.122119E+10 | 0.00 | 0.00 | 501545.94 | 0.00 | 0.201680E+10 | 0.209685E+09 | 0.00 | 0.39 |
Annual Sum or Average | 0.196034E+11 | 5357054.24 | 0.00 | 59495286.30 | 12250311.33 | 0.712758E+10 | 0.302060E+11 | 0.00 | 0.87 |
Minimum of Months | 0.112421E+10 | 0.00 | 0.00 | 314762.97 | 0.00 | 0.00 | 0.209685E+09 | 0.00 | 0.39 |
Maximum of Months | 0.251552E+10 | 2783772.52 | 0.00 | 10562811.06 | 7557675.69 | 0.201680E+10 | 0.472662E+10 | 0.00 | 1.65 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.989672E+09 | 0.00 | 0.00 | 3831.15 | 0.00 | 0.165740E+10 | 9610982.10 | 0.00 | 0.45 |
February | 0.115404E+10 | 0.00 | 0.00 | 126615.25 | 0.00 | 0.109930E+10 | 0.121397E+09 | 0.00 | 0.46 |
March | 0.180277E+10 | 0.00 | 0.00 | 93885.39 | 0.00 | 0.841262E+09 | 79060227.63 | 0.00 | 0.50 |
April | 0.168958E+10 | 0.00 | 0.00 | 3493205.04 | 680940.98 | 0.114306E+09 | 0.182435E+10 | 0.00 | 0.89 |
May | 0.176308E+10 | 0.00 | 0.00 | 4155479.16 | 0.00 | 29520223.29 | 0.228497E+10 | 0.00 | 1.02 |
June | 0.115192E+10 | 12779364.00 | 0.00 | 5883683.76 | 1299503.78 | 359373.89 | 0.299060E+10 | 0.00 | 1.44 |
July | 0.860627E+09 | 1861783.49 | 0.00 | 7163737.65 | 2805190.80 | 0.00 | 0.291299E+10 | 0.00 | 1.54 |
August | 0.957523E+09 | 0.00 | 0.00 | 5847578.39 | 0.00 | 0.00 | 0.240381E+10 | 0.00 | 1.54 |
September | 0.148613E+10 | 0.00 | 0.00 | 3033754.68 | 0.00 | 8397295.00 | 0.158033E+10 | 0.00 | 1.18 |
October | 0.177535E+10 | 0.00 | 0.00 | 731414.24 | 0.00 | 0.361971E+09 | 0.503088E+09 | 0.00 | 0.63 |
November | 0.126465E+10 | 0.00 | 0.00 | 12896.57 | 0.00 | 0.101712E+10 | 32366283.68 | 0.00 | 0.47 |
December | 0.616258E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.189355E+10 | 0.00 | 0.00 | 0.44 |
Annual Sum or Average | 0.155116E+11 | 14641147.49 | 0.00 | 30546081.30 | 4785635.57 | 0.702319E+10 | 0.147426E+11 | 0.00 | 0.88 |
Minimum of Months | 0.616258E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.44 |
Maximum of Months | 0.180277E+10 | 12779364.00 | 0.00 | 7163737.65 | 2805190.80 | 0.189355E+10 | 0.299060E+10 | 0.00 | 1.54 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.112072E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.170157E+10 | 0.00 | 0.00 | 0.28 |
February | 0.132504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115292E+10 | 0.00 | 0.00 | 0.28 |
March | 0.212222E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.685613E+09 | 0.00 | 0.00 | 0.31 |
April | 0.235771E+10 | 0.00 | 0.00 | 199085.05 | 20594.99 | 26400101.69 | 0.267297E+09 | 0.00 | 0.39 |
May | 0.215718E+10 | 0.00 | 0.00 | 954158.34 | 0.00 | 0.00 | 0.720312E+09 | 0.00 | 0.43 |
June | 0.109138E+10 | 2855904.54 | 0.00 | 3218902.07 | 6822414.47 | 0.00 | 0.187992E+10 | 0.00 | 0.63 |
July | 0.880195E+09 | 2432902.00 | 0.00 | 3950004.15 | 612400.62 | 0.00 | 0.188153E+10 | 0.00 | 0.70 |
August | 0.102766E+10 | 0.00 | 0.00 | 3328769.02 | 0.00 | 0.00 | 0.153173E+10 | 0.00 | 0.73 |
September | 0.163834E+10 | 0.00 | 0.00 | 1480818.93 | 32659.40 | 0.00 | 0.896547E+09 | 0.00 | 0.56 |
October | 0.245179E+10 | 0.00 | 0.00 | 36673.84 | 0.00 | 41517633.55 | 0.124593E+09 | 0.00 | 0.37 |
November | 0.207593E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.421231E+09 | 0.00 | 0.00 | 0.29 |
December | 0.116216E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.152100E+10 | 0.00 | 0.00 | 0.27 |
Annual Sum or Average | 0.194103E+11 | 5288806.53 | 0.00 | 13168411.38 | 7488069.48 | 0.555025E+10 | 0.730193E+10 | 0.00 | 0.44 |
Minimum of Months | 0.880195E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.27 |
Maximum of Months | 0.245179E+10 | 2855904.54 | 0.00 | 3950004.15 | 6822414.47 | 0.170157E+10 | 0.188153E+10 | 0.00 | 0.73 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.113915E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.110187E+10 | 0.00 | 0.00 | 0.35 |
February | 0.127957E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.685586E+09 | 0.00 | 0.00 | 0.35 |
March | 0.174766E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.478717E+09 | 0.00 | 0.00 | 0.38 |
April | 0.951634E+09 | 53780.46 | 0.00 | 3143917.81 | 0.00 | 2136102.64 | 0.182239E+10 | 0.00 | 0.68 |
May | 0.925679E+09 | 0.00 | 0.00 | 3880962.79 | 0.00 | 0.00 | 0.221165E+10 | 0.00 | 0.79 |
June | 0.561589E+09 | 2770600.77 | 0.00 | 5285856.91 | 5395376.70 | 0.00 | 0.269277E+10 | 0.00 | 1.14 |
July | 0.429625E+09 | 4691241.13 | 0.00 | 6055397.74 | 484305.38 | 0.00 | 0.266053E+10 | 0.00 | 1.23 |
August | 0.452182E+09 | 0.00 | 0.00 | 6249765.95 | 0.00 | 0.00 | 0.263545E+10 | 0.00 | 1.40 |
September | 0.758244E+09 | 0.00 | 0.00 | 4376935.37 | 25828.06 | 0.00 | 0.219474E+10 | 0.00 | 1.09 |
October | 0.161745E+10 | 0.00 | 0.00 | 855577.36 | 0.00 | 26826801.02 | 0.589914E+09 | 0.00 | 0.50 |
November | 0.169040E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.288970E+09 | 0.00 | 0.00 | 0.37 |
December | 0.103917E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109155E+10 | 0.00 | 0.00 | 0.34 |
Annual Sum or Average | 0.125924E+11 | 7515622.36 | 0.00 | 29848413.93 | 5905510.14 | 0.367565E+10 | 0.148074E+11 | 0.00 | 0.72 |
Minimum of Months | 0.429625E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.34 |
Maximum of Months | 0.174766E+10 | 4691241.13 | 0.00 | 6249765.95 | 5395376.70 | 0.110187E+10 | 0.269277E+10 | 0.00 | 1.40 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.114536E+10 | 0.00 | 0.00 | 121176.36 | 0.00 | 0.305903E+10 | 0.103537E+09 | 0.00 | 0.42 |
February | 0.145149E+10 | 0.00 | 0.00 | 149662.35 | 0.00 | 0.209096E+10 | 0.157209E+09 | 0.00 | 0.41 |
March | 0.162332E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.261055E+10 | 0.00 | 0.00 | 0.46 |
April | 0.188365E+10 | 0.00 | 0.00 | 2720532.08 | 24355.94 | 0.691304E+09 | 0.154574E+10 | 0.00 | 0.64 |
May | 0.214851E+10 | 0.00 | 0.00 | 1871742.07 | 0.00 | 0.720379E+09 | 0.123663E+10 | 0.00 | 0.64 |
June | 0.188284E+10 | 4858920.92 | 0.00 | 2706799.75 | 8068290.19 | 0.294201E+09 | 0.145898E+10 | 0.00 | 0.80 |
July | 0.125375E+10 | 4291436.60 | 0.00 | 4492702.12 | 724234.20 | 0.117534E+09 | 0.210323E+10 | 0.00 | 0.92 |
August | 0.100481E+10 | 0.00 | 0.00 | 7020317.67 | 0.00 | 0.107705E+09 | 0.285963E+10 | 0.00 | 1.22 |
September | 0.116073E+10 | 71133.84 | 0.00 | 6919846.75 | 0.00 | 0.275296E+09 | 0.331793E+10 | 0.00 | 1.20 |
October | 0.192821E+10 | 0.00 | 0.00 | 2221734.11 | 0.00 | 0.878040E+09 | 0.156770E+10 | 0.00 | 0.64 |
November | 0.178478E+10 | 0.00 | 0.00 | 147748.28 | 0.00 | 0.178811E+10 | 0.128545E+09 | 0.00 | 0.43 |
December | 0.719702E+09 | 0.00 | 0.00 | 10553.19 | 0.00 | 0.334375E+10 | 13083768.54 | 0.00 | 0.41 |
Annual Sum or Average | 0.179872E+11 | 9221491.36 | 0.00 | 28382814.74 | 8816880.34 | 0.159769E+11 | 0.144922E+11 | 0.00 | 0.68 |
Minimum of Months | 0.719702E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107705E+09 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.214851E+10 | 4858920.92 | 0.00 | 7020317.67 | 8068290.19 | 0.334375E+10 | 0.331793E+10 | 0.00 | 1.22 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.121963E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129556E+10 | 0.00 | 0.00 | 0.39 |
February | 0.148325E+10 | 0.00 | 0.00 | 42785.10 | 0.00 | 0.662905E+09 | 60003210.90 | 0.00 | 0.39 |
March | 0.194446E+10 | 0.00 | 0.00 | 17501.70 | 0.00 | 0.534395E+09 | 21312848.07 | 0.00 | 0.43 |
April | 0.164089E+10 | 0.00 | 0.00 | 2189923.23 | 18286.54 | 18072256.68 | 0.111515E+10 | 0.00 | 0.68 |
May | 0.143028E+10 | 0.00 | 0.00 | 3241800.34 | 0.00 | 758580.89 | 0.179223E+10 | 0.00 | 0.82 |
June | 0.732338E+09 | 12724226.14 | 0.00 | 4948713.83 | 1396431.18 | 0.00 | 0.258957E+10 | 0.00 | 1.17 |
July | 0.596395E+09 | 3193348.95 | 0.00 | 6130874.64 | 309127.50 | 0.00 | 0.255074E+10 | 0.00 | 1.31 |
August | 0.625852E+09 | 0.00 | 0.00 | 5231728.60 | 0.00 | 0.00 | 0.216696E+10 | 0.00 | 1.29 |
September | 0.115019E+10 | 6469.86 | 0.00 | 2891112.76 | 25078.70 | 0.00 | 0.150234E+10 | 0.00 | 1.00 |
October | 0.200796E+10 | 0.00 | 0.00 | 638072.59 | 0.00 | 39860385.14 | 0.427346E+09 | 0.00 | 0.56 |
November | 0.184252E+10 | 0.00 | 0.00 | 6751.06 | 0.00 | 0.363075E+09 | 16617012.63 | 0.00 | 0.41 |
December | 0.100339E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.138874E+10 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | 0.156772E+11 | 15924044.96 | 0.00 | 25339263.85 | 1748923.92 | 0.430336E+10 | 0.122423E+11 | 0.00 | 0.74 |
Minimum of Months | 0.596395E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 |
Maximum of Months | 0.200796E+10 | 12724226.14 | 0.00 | 6130874.64 | 1396431.18 | 0.138874E+10 | 0.258957E+10 | 0.00 | 1.31 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.144638E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123297E+10 | 0.00 | 0.00 | 0.28 |
February | 0.167493E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.708217E+09 | 0.00 | 0.00 | 0.28 |
March | 0.235424E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.367536E+09 | 0.00 | 0.00 | 0.30 |
April | 0.167396E+10 | 140555.23 | 0.00 | 1527767.70 | 0.00 | 10143436.34 | 0.109819E+10 | 0.00 | 0.42 |
May | 0.146130E+10 | 0.00 | 0.00 | 2866982.75 | 0.00 | 0.00 | 0.178466E+10 | 0.00 | 0.51 |
June | 0.693899E+09 | 4542782.03 | 0.00 | 5551295.12 | 6476065.59 | 0.00 | 0.290249E+10 | 0.00 | 0.78 |
July | 0.674095E+09 | 5528594.12 | 0.00 | 5548105.02 | 860839.98 | 0.00 | 0.260143E+10 | 0.00 | 0.85 |
August | 0.764638E+09 | 0.00 | 0.00 | 5120582.19 | 0.00 | 0.00 | 0.219578E+10 | 0.00 | 0.87 |
September | 0.135481E+10 | 0.00 | 0.00 | 2567108.55 | 112259.66 | 0.00 | 0.136929E+10 | 0.00 | 0.64 |
October | 0.218248E+10 | 0.00 | 0.00 | 252477.89 | 0.00 | 54057915.28 | 0.242856E+09 | 0.00 | 0.36 |
November | 0.192040E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.445112E+09 | 0.00 | 0.00 | 0.29 |
December | 0.118602E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136271E+10 | 0.00 | 0.00 | 0.27 |
Annual Sum or Average | 0.173872E+11 | 10211931.37 | 0.00 | 23434319.22 | 7449165.23 | 0.418075E+10 | 0.121947E+11 | 0.00 | 0.49 |
Minimum of Months | 0.674095E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.27 |
Maximum of Months | 0.235424E+10 | 5528594.12 | 0.00 | 5551295.12 | 6476065.59 | 0.136271E+10 | 0.290249E+10 | 0.00 | 0.87 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.153364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.112925E+10 | 0.00 | 0.00 | 0.43 |
February | 0.169667E+10 | 0.00 | 0.00 | 10233.70 | 0.00 | 0.650450E+09 | 20593400.69 | 0.00 | 0.43 |
March | 0.233187E+10 | 0.00 | 0.00 | 680.26 | 0.00 | 0.364205E+09 | 6709640.39 | 0.00 | 0.48 |
April | 0.110333E+10 | 529810.04 | 0.00 | 4351487.48 | 0.00 | 3342743.32 | 0.244159E+10 | 0.00 | 0.86 |
May | 0.122656E+10 | 0.00 | 0.00 | 4831797.18 | 0.00 | 289878.34 | 0.268054E+10 | 0.00 | 0.97 |
June | 0.723867E+09 | 3235474.08 | 0.00 | 6296705.15 | 6420824.52 | 0.00 | 0.320030E+10 | 0.00 | 1.35 |
July | 0.646285E+09 | 9375576.18 | 0.00 | 6831870.14 | 853496.98 | 0.00 | 0.293280E+10 | 0.00 | 1.43 |
August | 0.671559E+09 | 0.00 | 0.00 | 6831120.05 | 0.00 | 0.00 | 0.285368E+10 | 0.00 | 1.60 |
September | 0.110276E+10 | 0.00 | 0.00 | 4578529.31 | 111302.08 | 0.00 | 0.225120E+10 | 0.00 | 1.24 |
October | 0.191462E+10 | 0.00 | 0.00 | 961951.45 | 0.00 | 62030577.58 | 0.626362E+09 | 0.00 | 0.59 |
November | 0.193426E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.416577E+09 | 0.00 | 0.00 | 0.45 |
December | 0.122011E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131048E+10 | 0.00 | 0.00 | 0.42 |
Annual Sum or Average | 0.161055E+11 | 13140860.30 | 0.00 | 34694374.73 | 7385623.59 | 0.393662E+10 | 0.170138E+11 | 0.00 | 0.86 |
Minimum of Months | 0.646285E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 0.233187E+10 | 9375576.18 | 0.00 | 6831870.14 | 6420824.52 | 0.131048E+10 | 0.320030E+10 | 0.00 | 1.60 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.223677E+10 | 0.00 | 0.00 | 1573855.61 | 0.00 | 0.102036E+10 | 0.766747E+09 | 0.00 | 0.41 |
February | 0.228312E+10 | 0.00 | 0.00 | 2091049.79 | 0.00 | 0.469345E+09 | 0.103224E+10 | 0.00 | 0.44 |
March | 0.310825E+10 | 0.00 | 0.00 | 517908.71 | 0.00 | 0.366247E+09 | 0.361766E+09 | 0.00 | 0.43 |
April | 0.156111E+10 | 194397.93 | 0.00 | 8755308.25 | 0.00 | 10578525.87 | 0.443885E+10 | 0.00 | 0.96 |
May | 0.179743E+10 | 0.00 | 0.00 | 6965282.62 | 0.00 | 899096.22 | 0.386323E+10 | 0.00 | 0.91 |
June | 0.120873E+10 | 6162421.09 | 0.00 | 7843438.23 | 8956861.96 | 0.00 | 0.403893E+10 | 0.00 | 1.17 |
July | 0.103958E+10 | 8770857.01 | 0.00 | 8951140.84 | 1252874.89 | 0.00 | 0.389890E+10 | 0.00 | 1.30 |
August | 0.941714E+09 | 0.00 | 0.00 | 11097797.22 | 0.00 | 0.00 | 0.432251E+10 | 0.00 | 1.64 |
September | 0.132611E+10 | 232724.94 | 0.00 | 10610904.34 | 14881.70 | 0.00 | 0.478255E+10 | 0.00 | 1.57 |
October | 0.221165E+10 | 0.00 | 0.00 | 4942390.76 | 0.00 | 61658814.98 | 0.284914E+10 | 0.00 | 0.79 |
November | 0.245519E+10 | 0.00 | 0.00 | 1467775.39 | 0.00 | 0.388995E+09 | 0.711934E+09 | 0.00 | 0.44 |
December | 0.192537E+10 | 0.00 | 0.00 | 710062.25 | 0.00 | 0.139317E+10 | 0.311818E+09 | 0.00 | 0.39 |
Annual Sum or Average | 0.220950E+11 | 15360400.96 | 0.00 | 65526914.01 | 10224618.55 | 0.371125E+10 | 0.313786E+11 | 0.00 | 0.87 |
Minimum of Months | 0.941714E+09 | 0.00 | 0.00 | 517908.71 | 0.00 | 0.00 | 0.311818E+09 | 0.00 | 0.39 |
Maximum of Months | 0.310825E+10 | 8770857.01 | 0.00 | 11097797.22 | 8956861.96 | 0.139317E+10 | 0.478255E+10 | 0.00 | 1.64 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.158638E+10 | 0.00 | 0.00 | 12774.96 | 0.00 | 0.113685E+10 | 18227190.35 | 0.00 | 0.45 |
February | 0.176511E+10 | 0.00 | 0.00 | 209541.45 | 0.00 | 0.528141E+09 | 0.167839E+09 | 0.00 | 0.45 |
March | 0.234486E+10 | 0.00 | 0.00 | 139263.17 | 0.00 | 0.349169E+09 | 0.107018E+09 | 0.00 | 0.49 |
April | 0.167903E+10 | 0.00 | 0.00 | 3586323.43 | 143549.89 | 15362528.02 | 0.180689E+10 | 0.00 | 0.87 |
May | 0.155282E+10 | 0.00 | 0.00 | 4565563.84 | 0.00 | 910015.67 | 0.239666E+10 | 0.00 | 1.01 |
June | 0.864361E+09 | 19323254.91 | 0.00 | 6218072.91 | 1006502.08 | 0.00 | 0.308050E+10 | 0.00 | 1.40 |
July | 0.763458E+09 | 6901673.74 | 0.00 | 7366209.19 | 415428.52 | 0.00 | 0.280771E+10 | 0.00 | 1.51 |
August | 0.764418E+09 | 0.00 | 0.00 | 6254539.99 | 0.00 | 0.00 | 0.242139E+10 | 0.00 | 1.51 |
September | 0.134644E+10 | 132619.54 | 0.00 | 3476989.21 | 0.00 | 0.00 | 0.170502E+10 | 0.00 | 1.18 |
October | 0.210859E+10 | 0.00 | 0.00 | 883483.71 | 0.00 | 67902345.86 | 0.572384E+09 | 0.00 | 0.64 |
November | 0.190346E+10 | 0.00 | 0.00 | 42600.18 | 0.00 | 0.465785E+09 | 52575365.44 | 0.00 | 0.47 |
December | 0.119005E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141745E+10 | 0.00 | 0.00 | 0.44 |
Annual Sum or Average | 0.178690E+11 | 26357548.19 | 0.00 | 32755362.04 | 1565480.49 | 0.398157E+10 | 0.151362E+11 | 0.00 | 0.87 |
Minimum of Months | 0.763458E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.44 |
Maximum of Months | 0.234486E+10 | 19323254.91 | 0.00 | 7366209.19 | 1006502.08 | 0.141745E+10 | 0.308050E+10 | 0.00 | 1.51 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2024-07-03 12:20:09
Custom Monthly ReportSITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
January | 0.862924E+11 | 0.603162E+10 | 0.00 | 0.171984E+12 | 0.198745E+11 |
February | 0.132108E+12 | 0.603116E+10 | 0.00 | 0.162504E+12 | 0.139420E+11 |
March | 0.153447E+12 | 0.572091E+10 | 0.00 | 0.189067E+12 | 0.126311E+11 |
April | 0.393319E+12 | 0.486849E+10 | 0.00 | 0.242317E+12 | 0.819325E+10 |
May | 0.469457E+12 | 0.718676E+10 | 0.00 | 0.258147E+12 | 0.107235E+11 |
June | 0.469974E+12 | 0.538963E+10 | 0.00 | 0.263345E+12 | 0.328411E+11 |
July | 0.476042E+12 | 0.455088E+10 | 0.00 | 0.263685E+12 | 0.546538E+11 |
August | 0.393392E+12 | 0.378824E+10 | 0.00 | 0.244709E+12 | 0.683463E+11 |
September | 0.298899E+12 | 0.444142E+10 | 0.00 | 0.262712E+12 | 0.343584E+11 |
October | 0.141057E+12 | 0.553266E+10 | 0.00 | 0.212293E+12 | 0.495831E+10 |
November | 0.633246E+11 | 0.668905E+10 | 0.00 | 0.181911E+12 | 0.114478E+11 |
December | 0.325786E+11 | 0.794546E+10 | 0.00 | 0.161745E+12 | 0.202772E+11 |
Annual Sum or Average | 0.310989E+13 | 0.681763E+11 | 0.00 | 0.261442E+13 | 0.292247E+12 |
Minimum of Months | 0.325786E+11 | 0.378824E+10 | 0.00 | 0.161745E+12 | 0.495831E+10 |
Maximum of Months | 0.476042E+12 | 0.794546E+10 | 0.00 | 0.263685E+12 | 0.683463E+11 |