Cost-Effectiveness Analysis of the 2021 IECC for the State of Michigan

Document Number: PNNL-SA-188473
Document Type: Cost-effectiveness
Publication Date:

The State of Michigan is in the process of updating its current state residential energy code, which is an amended version of the 2015 International Energy Conservation Code (IECC) to the 2021 IECC. The Michigan Bureau of Construction Codes, a bureau within Licensing and Regulatory Affairs (LARA), requested a cost-effectiveness analysis, that considers the Michigan Stille-Derossett-Hale Single State Construction Code Act,1 comparing the current state residential energy code to the unamended 2021 IECC.

The resulting analysis shows that a home designed to comply with the residential provisions of the 2021 IECC would yield short-term and long-term consumer benefits compared to a home built to the Michigan-amended 2015 IECC.

2015 IECC: Energy Savings Analysis

Document Number: PNNL-23977
Document Type: Analysis, Determination
Publication Date:

Technical analysis in support of the 2015 IECC Determination.

Residential Prototype Building Models 2015 IECC - Climate Zone 5C

Document Type: Model Data
Publication Date:

The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the recent versions of the IECC are available for each climate.

Hawaii Certification of Commercial and Residential Building Energy Codes - Standard 90.1-2013 and 2015 IECC

Document Type: State-specific, State Certification
Publication Date:

Residential Prototype Building Models 2015 IECC - Climate Zone 8

Document Type: Model Data
Publication Date:

The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the recent versions of the IECC are available for each climate.

Residential Prototype Building Models 2015 IECC - Climate Zone 7

Document Type: Model Data
Publication Date:

The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the recent versions of the IECC are available for each climate.

Residential Prototype Building Models 2015 IECC - Climate Zone 6B

Document Type: Model Data
Publication Date:

The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the recent versions of the IECC are available for each climate.

Residential Prototype Building Models 2015 IECC - Climate Zone 6A

Document Type: Model Data
Publication Date:

The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the recent versions of the IECC are available for each climate.

Residential Prototype Building Models 2015 IECC - Climate Zone 5B

Document Type: Model Data
Publication Date:

The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the recent versions of the IECC are available for each climate.

Residential Prototype Building Models 2015 IECC - Climate Zone 5A

Document Type: Model Data
Publication Date:

The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the recent versions of the IECC are available for each climate.

Residential Prototype Building Models 2015 IECC - Climate Zone 4C

Document Type: Model Data
Publication Date:

The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the recent versions of the IECC are available for each climate.

Residential Prototype Building Models 2015 IECC - Climate Zone 4B

Document Type: Model Data
Publication Date:

The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the recent versions of the IECC are available for each climate.

Residential Prototype Building Models 2015 IECC - Climate Zone 4A

Document Type: Model Data
Publication Date:

The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the recent versions of the IECC are available for each climate.

Residential Prototype Building Models 2015 IECC - Climate Zone 3C

Document Type: Model Data
Publication Date:

The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the recent versions of the IECC are available for each climate.

Residential Prototype Building Models 2015 IECC - Climate Zone 3B

Document Type: Model Data
Publication Date:

The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the recent versions of the IECC are available for each climate.

Residential Prototype Building Models 2015 IECC - Climate Zone 3A

Document Type: Model Data
Publication Date:

The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the recent versions of the IECC are available for each climate.

Residential Prototype Building Models 2015 IECC - Climate Zone 2B

Document Type: Model Data
Publication Date:

The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the recent versions of the IECC are available for each climate.

Residential Prototype Building Models 2015 IECC - Climate Zone 2A

Document Type: Model Data
Publication Date:

The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the recent versions of the IECC are available for each climate.

Residential Prototype Building Models 2015 IECC - Climate Zone 1A

Document Type: Model Data
Publication Date:

The International Energy Conservation Code (IECC) prototype building models (prototype models) were developed by Pacific Northwest National Laboratory (PNNL), in support of DOE's Building Energy Codes Program (BECP), to simulate energy savings associated with changes in energy codes and standards. For residential buildings, PNNL utilized two base prototypes to simulate both Single-family detached house, and Multi-family low-rise apartment building types. Energy models for the recent versions of the IECC are available for each climate.

Texas Certification of Commercial and Residential Building Energy Codes - Standard 90.1-2013 and 2015 IECC

Document Type: State Certification, State-specific
Publication Date:

Florida Certification of Residential Building Energy Codes - 2015 IECC

Document Type: State Certification, State-specific
Publication Date:

Alabama Certification of Residential Building Energy Codes - 2015 IECC

Document Type: State Certification, State-specific
Publication Date:

National Cost-effectiveness of 2015 IECC

Document Number: PNNL-24240
Document Type: Analysis
Publication Date:

These analyses evaluate the cost-effectiveness of the prescriptive path of the 2015 edition of the International Energy Conservation Code (IECC), relative to the 2012 and 2009 IECC for all 50 states and the District of Columbia. The analysis covers one- and two-family dwelling units, town-homes, and low-rise multifamily residential buildings covered by the residential provisions of the 2015 IECC.

Cost-effectiveness Analysis of 2015 IECC - Wyoming

Document Number: PNNL-24974 Rev-1
Document Type: Analysis, Cost-effectiveness
Publication Date:

These analyses evaluate the cost-effectiveness of the prescriptive path of the 2015 edition of the International Energy Conservation Code (IECC), relative to the 2012 and 2009 IECC for all 50 states and the District of Columbia. The analysis covers one- and two-family dwelling units, town-homes, and low-rise multifamily residential buildings covered by the residential provisions of the 2015 IECC.

Cost-effectiveness Analysis of 2015 IECC - Wisconsin

Document Number: PNNL-24932 Rev-1
Document Type: Analysis, Cost-effectiveness
Publication Date:

These analyses evaluate the cost-effectiveness of the prescriptive path of the 2015 edition of the International Energy Conservation Code (IECC), relative to the 2012 and 2009 IECC for all 50 states and the District of Columbia. The analysis covers one- and two-family dwelling units, town-homes, and low-rise multifamily residential buildings covered by the residential provisions of the 2015 IECC.