What is considered a residential building?

The term “residential building” includes:

  1. detached one-or-two family dwellings having not more than three stories above grade plane;
  2. buildings that consist of three or more attached townhouse units and have not more than three stories above grade plane;
  3. buildings that are classified in Group R-2, R-3 or R-4 and have not more than three stories above grade plane

How do mixed use buildings need to meet code?

The IECC addresses mixed occupancies by stating that commercial occupancies must comply with the commercial portion of the code and residential occupancies must comply with the residential portion of the code.  

ASHRAE Standard 90.1 addresses high-rise residential and all other commercial buildings.  Residential spaces are those used primarily for living and sleeping and include dwelling units, hotel/motel guest rooms, dormitories, nursing homes, patient rooms in hospitals, lodging houses, fraternity/sorority houses, hostels, prisons, and fire stations.

What are the lighting requirements for residences?

The 2009 IECC requires that a minimum of 50% of the lamps in permanently installed lighting fixtures be high-efficacy lamps (2009 IECC, Section 404.1). The 2012 IECC has increased the minimum percentage from 50% to 75%, along with an exception for low-voltage lighting (2012 IECC, Section R404.1).

REScheck currently does not have a lighting input function; therefore, the lighting requirement should be confirmed under the Requirements Tab in the program.